MACHINE_NO
stringclasses 48
values | ERROR_ID
int64 1
999
| ERROR_CODE
stringclasses 245
values | ERROR_DESC
stringlengths 14
179
| ERROR_CATEGORY1
stringclasses 11
values | SOLUTION
stringlengths 40
290
|
---|---|---|---|---|---|
KM-ASSYM3-03
| 11 |
M80
|
M80-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X6)
|
Abnormal personnel operation
|
The solution for the error M80-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X6) is to verify that the safety door is closed and the emergency stop switch is disabled before starting the machine
|
KM-ASSYM3-03
| 12 |
M81
|
M81-Equipment model setting has not been set, please set the device model
|
Abnormal personnel operation
|
The solution for the error "M81-Equipment model setting has not been set, please set the device model" is to open the device manager, identify the problematic device, right-click and select "Properties," then click on
|
KM-ASSYM3-03
| 13 |
M82
|
M82-The automatic process has not been reset before starting, please press the reset button first
|
Abnormal personnel operation
|
The solution for this error is to reset the automatic process, press the reset button, and then start the process again.
|
KM-ASSYM3-03
| 14 |
M83
|
M83-The equipment Robot has not returned to the origin, please execute the equipment return to the origin first
|
Abnormal personnel operation
|
If equipment is not at the origin, the solution is to execute the equipment return to the origin first before conducting further tasks or operations. This will ensure that all equipment is accounted for and available when needed. It is important to ensure that all equipment
|
KM-ASSYM3-03
| 18 |
M87
|
M87-The feeding operation of the front waiting area has timed out, please check whether the board is stuck between the upstream and downstream of the machine
|
Organizational Abnormality
|
The solution to the error M87 is to check the board to see if it is stuck between the upstream and downstream of the machine. This usually occurs when a machine is stopped, and the conveyor belt stops, causing the downstream
|
KM-ASSYM3-03
| 19 |
M88
|
M88-The discharging operation of the front waiting area has timed out, please check whether the machine is stuck
|
Organizational Abnormality
|
The solution for M88 error is to check whether the machine is stuck by resetting the waiting queue or contacting technical support for further assistance.
|
KM-ASSYM3-03
| 20 |
M89
|
M89-The material feeding operation in the work area has timed out, please check whether the machine is jammed
|
Organizational Abnormality
|
The solution for the M89 error is to open the work area and check for any jammed material or blockage. If there is no jam, perform a restart of the machine while observing the material feed operation. If the error repeats
|
KM-ASSYM3-03
| 21 |
M90
|
M90-The discharging operation in the work area has timed out, please check whether there is any jamming between the upstream and downstream of the machine
|
Organizational Abnormality
|
The solution for the M90 error is to check for any jamming between the upstream and downstream of the machine. If there is jamming, it should be cleared before attempting the discharging operation again. If no jamming is
|
KM-ASSYM3-03
| 25 |
M94
|
M94-The jacking cylinder in the work area rises abnormally (X24), please check whether the cylinder is stuck when rising
|
Organizational Abnormality
|
The solution for M94 error is to investigate whether the jacking cylinder is stuck during its rise. To do this, the operator needs to verify whether the cylinder is free to move and if it's rising smoothly. If the cyl
|
KM-ASSYM3-03
| 26 |
M95
|
M95-The lifting cylinder in the work area is abnormally descending (X25), please check whether the cylinder is stuck when descending
|
Organizational Abnormality
|
The solution to the M95 error "The lifting cylinder in the work area is abnormally descending (X25), please check whether the cylinder is stuck when descending" is to check if the cylinder is stuck during
|
KM-ASSYM3-03
| 27 |
M96
|
M96-The work area blocking cylinder is rising abnormally (X26), please check whether the cylinder is stuck when rising
|
Organizational Abnormality
|
Check if the cylinder is stuck when rising. If the movement is restricted and the cylinder cannot fully extend, then the error M96-The work area blocking cylinder is rising abnormally (X26) may be caused by
|
KM-ASSYM3-03
| 28 |
M97
|
M97-The work area blocking cylinder is abnormally descending (X27), please check whether the cylinder is stuck when descending
|
Organizational Abnormality
|
The solution for M97 error with X27 is to confirm whether the cylinder is stuck while descending. The work area blocking cylinder could be descending abnormally due to several reasons, such as mechanical, electrical, or software
|
KM-ASSYM3-03
| 38 |
M107
|
M107-Robot has an abnormal alarm, please use Robot to eliminate the abnormality first
|
Electronic control abnormality
|
The solution to the M107-Robot error is to use the Robot tool to eliminate the abnormality that triggered the alarm. This can be done by identifying and correcting the cause of the abnormality, such as a
|
KM-ASSYM3-03
| 39 |
M108
|
M108-Assembly point deviation is too large
|
Electronic control abnormality
|
The M108-Assembly point deviation is too large error typically occurs in assembly code when attempting to perform a modification that exceeds the amount of memory available. To fix this issue, you may need to adjust the code to allocate less memory
|
KM-ASSYM3-03
| 41 |
M110
|
M110-single assembly less than 12 pieces
|
Other exceptions
|
The M110 error occurs when the number of assemblies being built falls below 12 pieces. Increase the number of assemblies through the project settings, or add additional assemblies to the project. If none of these
|
KM-ASSYM3-03
| 42 |
M111
|
The M111-MAKE point deviation is too large, please check whether the PCB board is abnormal
|
Visual abnormality
|
The solution for the error described as The M111-MAKE point deviation is too large is to check whether the PCB board is abnormal by verifying its design, layout, and connection. If the board is found to be
|
KM-ASSYM3-03
| 43 |
M112
|
M112-Make point photo failed, please check whether the PCB board is abnormal
|
Visual abnormality
|
The solution for the error "M112-Make point photo failed" is to check whether the PCB board is damaged or abnormal. This issue can be fixed by correcting the PCB design or board configuration, ensuring the board is
|
KM-ASSYM3-03
| 44 |
M113
|
M113-The left nozzle failed to pick up material for 3 consecutive times. Please check whether the Feeder discharging position is correct & whether the material belt is stuck
|
Electronic control abnormality
|
The solution for M113 error involves checking whether the Feeder discharging position is correct and if the material belt is stuck. If the feeder is not discharging material, adjust the discharge position. If the belt is stuck
|
KM-ASSYM3-03
| 45 |
M114
|
M114-The right nozzle failed to pick up material for 3 consecutive times. Please check whether the Feeder discharging position is correct & whether the material belt is stuck
|
Electronic control abnormality
|
The solution for the error M114 is to check the feeder discharging position and whether the material belt is stuck. If the feeder is discharging in the wrong position or the belt is stuck, the nozzle will
|
KM-ASSYM3-03
| 46 |
M115
|
M115-The left nozzle failed to detect 3 consecutive times at the lower camera. Please check whether the incoming material is abnormal
|
Electronic control abnormality
|
The solution for M115-The left nozzle failed to detect 3 consecutive times at the lower camera is likely due to a blockage in the material flow. To fix this issue, the lower camera needs to be inspected and
|
KM-ASSYM3-03
| 47 |
M116
|
M116-The right nozzle failed to detect 3 consecutive times at the lower camera. Please check whether the incoming material is abnormal
|
Visual abnormality
|
The solution to M116 errors is typically to check for any incoming material abnormalities that may be causing the nozzle to detect a problem. Any material that is too hard, too sticky, or too abrasive can affect
|
KM-ASSYM3-03
| 51 |
M120
|
M120-Camera connection failed, please reconnect the camera
|
Visual abnormality
|
The solution to the M120-Camera connection failed error is to reconnect your camera to your computer or to the app you are using and restart the camera and app. If the issue persists, it may be necessary to update the camera
|
KM-ASSYM3-03
| 52 |
M121
|
The connection between M121-Robot and CCD failed, please check the communication connection or network cable between Robot and CCD
|
Electronic control abnormality
|
The solution for the error "The connection between M121-Robot and CCD failed" would be to verify and check the communication connection or network cable between the Robot and CCD to ensure it is properly connected and functioning.
|
KM-ASSYM3-03
| 53 |
M122
|
No feedback within 30s from communication between M122-CCD and arm
|
Visual abnormality
|
The solution to the error "No feedback within 30s from communication between M122-CCD and arm" could involve checking for faulty hardware or software connections, ensuring that the correct communication protocol is being used, and making sure
|
KM-ASSYM3-03
| 54 |
M123
|
M123-CCD failed to send signal to arm
|
Visual abnormality
|
The solution for the error described as M123-CCD failed to send signal to arm may vary depending on the specific cause of the issue. It is recommended to consult the manual or contact the manufacturer for further assistance. Possible solutions include
|
KM-ASSYM3-03
| 55 |
M124
|
M124-CCD failed to send READY signal to the arm
|
Visual abnormality
|
This error usually indicates a hardware issue with the CCD camera controller in your robot arm. It may require updating or reprogramming the controller's firmware or software, or troubleshooting the controller's connections to ensure the arm receives
|
KM-ASSYM3-03
| 56 |
M125
|
M125-CCD failed to send START signal to the arm
|
Visual abnormality
|
The error message "M125-CCD failed to send start signal to the arm" occurs when the CCD (charge-coupled device) sensor sends an incorrect signal to the robotic arm, impeding its movement. To resolve
|
KM-ASSYM3-03
| 57 |
M126
|
M126-CCD failed to send CHECK signal to the arm
|
Visual abnormality
|
First check the sensor fusion and CCD system logs for any errors or warnings related to the M126-CCD check signal issue. If the issue persists, you may need to replace the CCD or perform firmware updates to resolve
|
KM-ASSYM3-03
| 58 |
M127
|
M127-CCD failed to send the MAKE signal to the arm
|
Visual abnormality
|
To diagnose the M127-CCD error, you should check if there is any loose wire or connection issue on the MAKE sensor. You can also reset the CCD device or update the firmware if needed. Replace/
|
KM-ASSYM3-03
| 60 |
M129
|
M129-CCD failed to send the material picking test result signal to the arm
|
Visual abnormality
|
The solution for the error "M129-CCD failed to send the material picking test result signal to the arm" may involve troubleshooting the communication between the CCD and the arm. It may also involve resetting or re
|
KM-ASSYM3-03
| 61 |
M130
|
M130-CCD failed to send the camera detection result to the arm
|
Visual abnormality
|
The solution to the M130-CCD error is to ensure that the camera is properly connected and functioning, that the communication settings are correct, and that the software is up-to-date. If the issue persists, adjusting
|
KM-ASSYM3-03
| 62 |
M131
|
M131-CCD failed to send the assembly point to the arm
|
Visual abnormality
|
The solution for the M131-CCD error is to ensure that the arm architecture of your computer matches the one expected by the program. You may need to update your compiler or change your code to use the correct syntax for your architecture.
|
KM-ASSYM3-03
| 63 |
M132
|
M132-CCD failed to send the completion signal to the arm
|
Visual abnormality
|
The error you described is likely related to a communication problem between the M132-CCD and the arm. This issue could be caused by a faulty cable, a malfunctioning device, or incorrect settings. To resolve this issue,
|
KM-ASSYM3-03
| 64 |
M133
|
M133-CCD timed out waiting for arm READY OK signal
|
Machine communication abnormality
|
The solution for the M133-CCD timed out waiting for arm READY OK signal error can be obtained by either adjusting the communication timeouts and retries or using a different communication protocol to establish contact with the CCD device
|
KM-ASSYM3-03
| 65 |
M134
|
M134-CCD timed out waiting for arm START OK signal
|
Machine communication abnormality
|
The M134-CCD error occurs when the Arduino attempts to communicate with the CCD module over the serial port, but the module does not respond within a specified time period. This error can be resolved by adjusting the b
|
KM-ASSYM4-01
| 40 |
M7039
|
M7039-The left blocking cylinder in the work area is abnormally descending (X41), please check whether the cylinder is stuck when descending
|
Organizational Abnormality
|
The error message M7039-The left blocking cylinder in the work area is abnormally descending (X41), please check whether the cylinder is stuck when descending indicates that there is an issue on a cylinder
|
KM-ASSYM4-01
| 41 |
M7040
|
M7040-The right blocking cylinder in the work area rises abnormally (X42), please check whether the cylinder is stuck when rising
|
Organizational Abnormality
|
The solution to the M7040-The right blocking cylinder in the work area rises abnormally (X42) error is to check if the cylinder is stuck when rising. If the cylinder is stuck, it
|
KM-ASSYM4-01
| 42 |
M7041
|
M7041-The right blocking cylinder in the work area is abnormally descending (X43), please check whether the cylinder is stuck when descending
|
Organizational Abnormality
|
The M7041 error message indicates that the right blocking cylinder is descending abnormally and could be stuck. The solution is to check the cylinder for possible mechanical or electrical issues, such as worn or damaged seals, fault
|
KM-ASSYM4-01
| 43 |
M7042
|
M7042-The jacking cylinder in the work area rises abnormally (X44), please check whether the cylinder is stuck when rising
|
Organizational Abnormality
|
The M7042 error occurs when the jacking cylinder in the work area rises abnormally. To resolve the error, check if the cylinder is stuck when it rises. If it is, try to release the cyl
|
KM-ASSYM4-01
| 44 |
M7043
|
M7043-The lifting cylinder in the work area is abnormally descending (X45), please check whether the cylinder is stuck when descending
|
Organizational Abnormality
|
The solution for the M7043 error is to check the lifting cylinder for any abnormalities and ensure that it is functioning properly. This may involve troubleshooting or disassembling and reassembling the cylinder depending on
|
KM-ASSYM4-01
| 50 |
M7049
|
M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), please check whether the cylinder is stuck when descending
|
Organizational Abnormality
|
If you encounter the error M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), it may indicate that the cylinder is stuck or has a problem with
|
KM-ASSYM4-01
| 51 |
M7050
|
M7050-The cylinder of the right glue cylinder in the slide area is rising abnormally (X55), please check whether the cylinder is stuck when rising
|
Organizational Abnormality
|
The M7050 error indicates that the right glue cylinder in the slide area is rising abnormally. To diagnose the issue, check whether the cylinder is stuck when rising. If it is, then the solution is to
|
KM-ASSYM4-01
| 53 |
M7052
|
M7052-The dispensing cylinder cylinder does not sense the upper limit before the slide area moves, please press the reset button first
|
Organizational Abnormality
|
The solution to M7052 error is to press the reset button before moving the slide area. This will restart the machine and allow the dispensing cylinder to sense the upper limit before dispensing. This will prevent the error from occurring again
|
KM-ASSYM4-01
| 54 |
M7053
|
M7053-The current glue amount is too much, please reduce it
|
Electronic control abnormality
|
Reduce the current glue amount by using less adhesive, replacing damaged parts, or adjusting the bonding process to ensure proper adhesion. In some cases, the use of a different type of adhesive or solvent may
|
KM-ASSYM4-01
| 55 |
M7054
|
M7054-The current dispensing amount is too small, please increase
|
Electronic control abnormality
|
The error M7054 usually occurs when the dispensing amount is less than the minimum amount required. To solve this error, you need to increase the dispensing amount by adjusting the settings on your printer or using a different ink cartr
|
KM-ASSYM4-01
| 65 |
M7064
|
M7064-X-axis servo NO readly(X15)&ERROR, please check whether the X-axis servo driver is abnormal
|
Electronic control abnormality
|
The solution for the error M7064-X-axis servo NO ready(X15)&ERROR could involve several steps. First, unplug and plug in the X-axis servo driver to check if the issue is with
|
KM-ASSYM4-01
| 67 |
M7066
|
M7066-X axis left limit is abnormal, far away from the origin end (X10), please check whether the slide table touches the limit
|
Electronic control abnormality
|
The solution for M7066-X axis left limit error is to verify whether the slide table is touching the limit. If it is touching the limit, adjust the limit switches to stop the slide table from touching. If it is not
|
KM-ASSYM4-01
| 69 |
M7068
|
M7068-Y-axis servo NO readly(X16)&ERROR, please check whether the X-axis servo driver is abnormal
|
Electronic control abnormality
|
The solution for the error described as M7068-Y-axis servo NO readly(X16) &ERROR is to confirm whether the X-axis servo driver is functioning correctly. This can be done by using the
|
KM-ASSYM4-01
| 71 |
M7070
|
M7070-Y axis rear limit is abnormal, far away from the origin end (X12), please check whether the slide table touches the limit
|
Electronic control abnormality
|
There are a few possible solutions to address the error M7070-Y axis rear limit is abnormal, far away from the origin end (X12) including:
1. Adjusting the slide table position to ensure
|
KM-ASSYM4-01
| 72 |
M7071
|
M7071-Y axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
|
Electronic control abnormality
|
The M7071-Y axis return to origin time has timed out error indicates that the Y-axis slide table is not responding to commands. This can be due to a stuck or abnormal condition. To troubleshoot this issue
|
KM-ASSYM4-01
| 73 |
M7072
|
M7072-Z-axis servo NO readly(X17)&ERROR, please check whether the Z-axis servo driver is abnormal
|
Electronic control abnormality
|
The error M7072-Z-axis servo NO readly(X17)&ERROR typically indicates an issue with the Z-axis servo driver circuitry. It is recommended to first check for wiring errors or loose connections
|
KM-ASSYM4-01
| 75 |
M7074
|
M7074-Z axis lower limit abnormality, far away from the origin end (X14), please check whether the slide table touches the limit
|
Electronic control abnormality
|
The solution for the error M7074 due to the lower limit abnormality of the Z-axis, far away from the origin end (X14), is to ensure that the slide table does not touch the limit. This can
|
KM-ASSYM4-01
| 76 |
M7075
|
M7075-Z axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
|
Electronic control abnormality
|
To resolve the M7075 error where the Z axis return to origin has timed out, make sure to check the slide table abnormality or sticking condition. If it is normal, the problem may be with the encoder or the
|
KM-ASSYM4-01
| 81 |
M7080
|
M7080-Camera acquisition failed
|
Visual abnormality
|
The M7080-Camera acquisition failed error occurs when the camera is unable to acquire a clear image due to poor lighting conditions, distortion in the lens, or incorrect settings. To resolve this issue, first reset the camera and then check
|
KM-ASSYM4-01
| 82 |
M7081
|
M7081-Timeout waiting for MARK point in place signal
|
Electronic control abnormality
|
This issue is often resolved by adjusting the default timeout value for the place signal waiting period in the configuration settings. You can either increase the timeout value or try implementing the "force Mark" button in the Mark dialog. If the issue persists,
|
KM-ASSYM4-01
| 83 |
M7082
|
M7082-MARK point recognition failed
|
Visual abnormality
|
The solution for the M7082-MARK point recognition failed error is to reset the device's memory and perform the point recognition process again. If the issue persists, it may be necessary to consult the device's manual or contact
|
KM-ASSYM4-01
| 84 |
M7083
|
M7083-CCD timed out waiting for PLC completion signal (please check D720=1)
|
Electronic control abnormality
|
The solution for the M7083-CCD timed out waiting for PLC completion signal error is to check that the D720=1 parameter is set correctly in the communication configuration of the PLC. If the parameter is
|
KM-ASSYM4-01
| 85 |
M7084
|
M7084-Scan code NG
|
Electronic control abnormality
|
The M7084-Scan code NG error often indicates a connectivity issue between the scanner and the computer or printer. A possible solution is to check the connections, restart the devices, and update device drivers. If the issue pers
|
KM-ASSYM4-01
| 86 |
M7085
|
M7085-TE reply card station Fail
|
Kazam exception
|
The solution for the error described as M7085-TE may vary depending on the specific issue and configuration of the system. It could involve resetting or updating the reply card station, checking for communication issues, or consulting the system documentation for
|
KM-ASSYM4-01
| 87 |
M7086
|
M7086-Scan code OK and receive TE Read signal timeout
|
Kazam exception
|
This error typically occurs when there is no data available on the USB port. It could be due to a problem with the computer's USB interface or a malfunctioning printer. To resolve the issue, you may need to try restarting your computer
|
KM-ASSYM4-01
| 88 |
M7087
|
M7087-TE LINK out of range
|
Kazam exception
|
The error M7087-TE LINK out of range typically occurs when the TTL setting of a router or access point is too low. To resolve this issue, you can increase the TTL setting on the router or access point,
|
KM-ASSYM4-01
| 89 |
M7088
|
M7088-TE LINK timeout
|
Kazam exception
|
The solution for the error described as M7088-TE LINK timeout involves checking the network connection, verifying the routing settings, and restarting the network or server.
|
KM-ASSYM4-01
| 91 |
M7090
|
M7090-PLC timed out waiting for the host computer to transmit the MARK point identification signal
|
Visual abnormality
|
The M7090-PLC error occurs when the host computer fails to transmit the MARK point identification signal within the specified timeline. To resolve this issue, first confirm that the host computer is correctly configured and sends the signal within the
|
KM-ASSYM4-01
| 92 |
M7091
|
M7091-PLC timed out waiting for the host computer to transmit the dispensing point position
|
Visual abnormality
|
The solution for M7091-PLC time-out error is to ensure that the host computer is transmitting dispensing point position information to the PLC. The issue could also be caused by communication between the two devices being disabled or
|
KM-ASSYM4-01
| 93 |
M7092
|
M7092-PLC timed out while waiting for the area identification completion signal from the host computer
|
Visual abnormality
|
The solution for the M7092-PLC timed out error involving area identification completion signal from the host computer could be to reduce the timeout value in the PLC configuration, check for network connectivity issues or congestion, or
|
KM-ASSYM4-01
| 95 |
M7094
|
M7094-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing
|
Visual abnormality
|
M7094-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing can be resolved by checking if the host computer is properly connected and also ensuring that there are no delays or issues with the
|
KM-ASSYM4-01
| 96 |
M7095
|
M7095-PLC timed out waiting for the host computer to transmit the weighing result
|
Machine communication abnormality
|
The solution for M7095-PLC timed out waiting for the host computer to transmit the weighing result can be resolved by checking the communication settings in the PLC and making sure they are correct, resetting the PLC and
|
KM-ASSYM4-01
| 97 |
M7096
|
M7096-Weighing machine communication abnormality
|
Electronic control abnormality
|
The M7096 error on a weighing machine indicates communication abnormality. The solution may involve resetting the machine, checking for any software updates, or contacting the manufacturer for further assistance. This issue typically occurs when the machine cannot
|
KM-ASSYM4-01
| 98 |
M7097
|
M7097-The cylinder position of the glue barrel is abnormal
|
Organizational Abnormality
|
M7097 errors occur when the glue barrel's cylinder position is abnormal. To resolve this issue, you can try calibrating the glue barrel, checking for blockage in the cylinder, or performing a manual
|
KM-ASSYM4-01
| 100 |
M7099
|
The current position of M7099-PCB board is lower than the safe distance, please check whether the PC board is placed properly
|
Other exceptions
|
The solution to the error "The current position of M7099-PCB board is lower than the safe distance, please check whether the PC board is placed properly" would be to double-check the placement of the M709
|
KM-ASSYM4-01
| 101 |
M7100
|
M7100-Please clean the scale pan before starting the machine, and click the Cleared button before starting the machine.
|
Abnormal personnel operation
|
The solution for this error is to clean the scale pan and click the "Cleared" button before starting the machine. If the pan cannot be cleaned, the machine must be powered off and unplugged for at least 30 minutes before
|
KM-ASSYM4-01
| 102 |
M7101
|
M7101-Please clean the scale pan and press the "Scale Pan Easy Clean Button"
|
Abnormal personnel operation
|
The solution for the error M7101 is to clean the scale pan using a cleaning tool provided by the scale manufacturer, and then to press the "Scale Pan Easy Clean Button" to reset the scale. If the problem persists, the
|
KM-ASSYM4-01
| 104 |
M7103
|
M7103 - The scan code of this site is OK, TE replies that the previous section has not passed the site or SFC failed to transmit data
|
Kazam exception
|
The solution for the error M7103, where SFC failed to transmit data before the previous section passed the site scan, is to make sure that the SFC (Scan Flexible Charge) cable is properly connected to the printer
|
KM-ASSYM4-01
| 105 |
M7104
|
M7104-The host computer did not read the READ signal sent by TE, LINK fail
|
Kazam exception
|
The M7104 error indicates that the host computer failed to read the READ signal sent by TE (Telecom Equipment) and resulted in a LINK fail. This issue may occur when the fiber optic cable is damaged, or there is
|
KM-ASSYM4-01
| 114 |
M7113
|
M7113-Current discharging point index is out of range
|
Visual abnormality
|
The solution to the M7113 error involves updating the current discharging point settings on the device in question to within the specified range. This can typically be done through the device's user manual or settings interface. If the issue pers
|
KM-ASSYM4-01
| 115 |
M7114
|
M7114-Timeout waiting for dispensing result
|
Visual abnormality
|
The M7114-Timeout waiting for dispensing result error typically occurs when the system is unable to complete a dispensing operation within a specified time limit. The solution may involve troubleshooting the hardware or software, adjusting the time
|
KM-ASSYM4-01
| 116 |
M7115
|
M7115-The discharge point exceeds the index range
|
Visual abnormality
|
The error "M7115-The discharge point exceeds the index range" indicates a problem in the discharge of stored procedures. To resolve this issue, you can check the discharge point value and modify it within the index range
|
KM-ASSYM4-01
| 117 |
M7116
|
M7116-Timeout waiting for next action
|
Machine communication abnormality
|
The M7116-Timeout waiting for next action error typically occurs when a software process is awaiting user input or a system event but is not receiving it within a specified timeout period. The solution may involve increasing the timeout limit, optimizing
|
KM-ASSYM5-04
| 6 |
M7007
|
Alarm: pressing position blocked_sensor double lights
|
Organizational Abnormality
|
There are several possible causes for this error, including a malfunctioning light sensor or an issue with the camera. However, the most common solution is to clean the affected area thoroughly and try again. If the problem persists, contact the manufacturer or
|
KM-ASSYM5-04
| 8 |
M7009
|
Alarm: pad pushes out cylinder 1_moving position alarm
|
Organizational Abnormality
|
The solution for the "pad pushes out cylinder 1_moving position alarm" error would likely involve checking the wiring and making sure that the pad and cylinder are properly aligned. It is recommended to contact a professional mechanic if
|
KM-ASSYM5-04
| 33 |
M7044
|
Alarm: During initialization, the assembly line materials were not cleared.
|
Abnormal personnel operation
|
To resolve the "Alarm: During initialization, the assembly line materials were not cleared." error, ensure that all materials are properly placed and cleared from the assembly line before beginning operations. This can prevent any potential issues during the initial setup of the production
|
KM-ASSYM5-04
| 34 |
M7045
|
Alarm: initial startup, there is material in the assembly line
|
Abnormal personnel operation
|
To fix the error described as Alarm: initial startup, there is material in the assembly line, you'll need to identify the source of the material and clear it from the assembly line. This may require adjusting your manufacturing processes or stopping production
|
KM-ASSYM5-05
| 1 |
M70
|
M70-The left labeling machine is out of material
|
Abnormal personnel operation
|
This error often occurs when the labeling machine runs out of labels or label stock. To solve it, ensure that the label machine has enough labels or label stock, and that the labels are properly loaded into the machine. Check the machine's settings
|
KM-ASSYM5-05
| 2 |
M71
|
M71-The right labeling machine is out of material
|
Abnormal personnel operation
|
To solve error M71-The right labeling machine is out of material, first, check to ensure that the correct labeling machine is in use and has sufficient material. If the machine is running low, you can either restock it or
|
KM-ASSYM5-05
| 3 |
M72
|
M72-The operation of the left label discharging machine has timed out, please check the label discharging machine
|
Electronic control abnormality
|
"The left label discharging machine has experienced a timeout Error M72. For assistance, please verify the label discharging machine's operation and adjust settings or contact system support for further troubleshooting."
|
KM-ASSYM5-05
| 5 |
M74
|
There is no feedback in the communication between M74-PLC and CCD, please restart the CCD part
|
Visual abnormality
|
The solution to this issue could potentially be to restart the CCD part, which could communicate with the M74-PLC and provide feedback. However, it's important to take note that this is just one possible solution and other underlying issues
|
PACKBOX
| 51 |
M7050
|
M7050-EMO&&DOOR is on. Please check the safety door and emergency stop switch
|
Abnormal personnel operation
|
The M7050-EMO&&DOOR is on error may be caused by a safety door issue or emergency stop switch problem. To resolve this issue, you should check the safety door sensors and make sure they are properly aligned and functioning
|
PACKBOX
| 53 |
M7052
|
M7052-The automatic process is not reset before starting, please press the reset button first
|
Abnormal personnel operation
|
The error M7052 typically appears when an automatic process is not reset properly before starting. To resolve this issue, you need to first press the reset button before starting the automatic process. This ensures that the process starts from its initial state and
|
KM-ASSYM3-03
| 67 |
M136
|
M136-CCD reading arm Arrive signal timed out
|
Visual abnormality
|
To fix the M136-CCD reading arm "Arrive signal timed out" error, you can try adjusting the timing settings of the reading arm, resetting the communication between devices, or checking for any possible interference with other
|
KM-ASSYM3-03
| 115 |
M7000
|
M7000-Manual/Automatic Switching
|
Other exceptions
|
The solution for M7000-Manual/Automatic Switching Error depends on the specific error message and circumstances. Resetting the switch or modem may fix the issue, while updating firmware or contacting technical support may also resolve
|
KM-ASSYM3-03
| 116 |
M7001
|
M7001-Device starting
|
Other exceptions
|
The solution for the error M7001-Device Starting may vary depending on the device and operating system, but usually involves resetting the device or performing a firmware update. It's recommended to consult the device's user manual or
|
KM-ASSYM3-03
| 117 |
M7002
|
M7002-Equipment is stopping
|
Other exceptions
|
The solution for an equipment error described as M7002-Equipment is stopping may require disassembling and resetting the system, updating firmware or drivers, contacting equipment manufacturer support for assistance, or resolving any hardware issues
|
KM-ASSYM3-03
| 118 |
M7003
|
M7003-Device in standby
|
Other exceptions
|
M7003-Device in standby typically occurs when the device, such as a wireless router or bridge, has been powered off for an extended period or is experiencing connectivity issues. To troubleshoot this error, first ensure that the
|
KM-ASSYM3-03
| 119 |
M7004
|
M7004-Equipment alarming
|
Other exceptions
|
The solution for M7004-Equipment alarming error would depend on the specific piece of equipment and issue causing it. It could be resolved by performing maintenance or repairs, checking connections or sensors, resetting parameters, or updating software
|
KM-ASSYM3-03
| 120 |
M7005
|
M7005-Pass function is enabled
|
Abnormal personnel operation
|
M7005 error means that the Pass function is enabled in your Excel spreadsheet. To fix this error, you need to disable the Pass function by going to the "Worksheet" tab and clicking on "Properties". In the "
|
KM-ASSYM3-03
| 59 |
M128
|
M128-CCD failed to send command to arm
|
Visual abnormality
|
The solution for the error described as M128-CCD failed to send command to ARM is to check the connection between the CCD camera and the ARM control unit. If the connection is loose or damaged, tighten it or replace it
|
KM-ASSYM3-03
| 66 |
M135
|
M135-CCD timed out waiting for arm Check point in place signal
|
Machine communication abnormality
|
The M135-CCD timed out waiting for arm check point in place signal error is typically caused by a configuration issue or hardware failure in Rigid Infrastructure Monitoring (RIGM) hardware. To resolve this error,
|
KM-ASSYM4-01
| 118 |
M7117
|
M7117-The number of required assemblies is more than the number of positioned cameras
|
Other exceptions
|
The M7117 error occurs when the number of required assemblies exceeds the number of positioned cameras in a camera-based manufacturing process. To resolve this issue, you can either increase the number of positioned cameras or optimize the assembly
|
KM-ASSYM4-01
| 119 |
M7118
|
M7118-CMC reply material number confirmation message timeout (10S)
|
Machine communication abnormality
|
The solution for the error M7118-CMC reply material number confirmation message timeout is to increase the timeout period to 10 seconds or set it to an appropriate value based on the system's requirements. Alternatively, checking the
|
KM-ASSYM4-01
| 121 |
M7120
|
M7120-The function of confirming the material number of the host computer CMC has been blocked
|
Other exceptions
|
To resolve M7120 error, ensure that the host computer CMC is functioning properly and has the necessary permissions to access the material number confirmation function. You may also need to update the system or application software to the latest version. If the
|