MACHINE_NO
stringclasses 48
values | ERROR_ID
int64 1
999
| ERROR_CODE
stringclasses 245
values | ERROR_DESC
stringlengths 14
179
| ERROR_CATEGORY1
stringclasses 11
values | SOLUTION
stringlengths 40
290
|
---|---|---|---|---|---|
KM-ASSYM4-01
| 52 |
M7051
|
M7051-The cylinder of the right glue cylinder in the slide area is abnormally descending (X61), please check whether the cylinder is stuck when descending
|
Organizational Abnormality
|
The M7051 error message indicates that the cylinder in the slide area is descending abnormally. This issue could be caused by the cylinder becoming stuck while descending. To resolve this, check the cylinder for any block
|
KM-ASSYM4-01
| 66 |
M7065
|
M7065-The right limit of the X-axis is abnormal, close to the origin end (X7), please check whether the slide table touches the limit
|
Electronic control abnormality
|
The solution for the M7065 error is to check if the slide table is touching the limit at the origin end (X7) and increase the left limit value if necessary to prevent the issue.
|
KM-ASSYM4-01
| 68 |
M7067
|
M7067-X axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
|
Electronic control abnormality
|
The error M7067 typically occurs when the X-axis slide table times out during its return to origin movement. This could be due to a malfunctioning actuator, a stuck slide table, or a problem with the home position
|
KM-ASSYM4-01
| 70 |
M7069
|
M7069-Y axis front limit is abnormal, close to the origin end (X11), please check whether the slide table touches the limit
|
Electronic control abnormality
|
The solution for M7069-Y axis front limit is abnormal, close to the origin end (X11) is to check whether the slide table touches the limit. The problem could be caused by the slide table moving too far
|
KM-ASSYM4-01
| 74 |
M7073
|
M7073-The limit on the Z axis is abnormal, close to the origin end (X13), please check whether the slide table touches the limit
|
Electronic control abnormality
|
The solution to M7073 error that states the limit on the Z axis is abnormal, close to the origin end (X13) is to check whether the slide table touches the limit. This can be accomplished by physically inspecting
|
KM-ASSYM4-01
| 90 |
M7089
|
M7089-The dispensing area detected by the upper camera is out of range
|
Visual abnormality
|
The solution for the M7089 error is to adjust the location and orientation of the upper camera to ensure it is within range of the dispensing area. If the camera cannot be moved, the error can also be resolved by adjusting the
|
KM-ASSYM4-01
| 94 |
M7093
|
M7093-PLC timed out waiting for the host computer to send the scan code result
|
Machine communication abnormality
|
The solution for the error described as M7093-PLC timed out waiting for the host computer to send the scan code result is to ensure that the host computer is properly connected and responsive, and that the PLC settings are
|
KM-ASSYM4-01
| 99 |
M7098
|
M7098-The current position of the PCB board exceeds the safe distance, please check whether the PC board is placed properly
|
Other exceptions
|
The solution to M7098 error is to check whether the PCB board is placed correctly and not exceeding the safe distance. The board should be centered properly and securely fastened to prevent any damage to the components or the board itself
|
KM-ASSYM4-01
| 103 |
M7102
|
M7102-Weighing machine reset failed
|
Electronic control abnormality
|
M7102-Weighing machine reset failed error typically occurs when the machine cannot initialize due to an incorrect password or issue with its software. To resolve this, consult the owner manual for instructions on resetting the machine and updating its firm
|
KM-ASSYM4-01
| 113 |
M7112
|
M7112-Visual software model number is inconsistent with PLC model number
|
Visual abnormality
|
The solution to the M7112 error is to check that the visual software model number matches the PLC model number. If both numbers are correct, then the error may be caused by a mismatch between the cable connections, power supply,
|
KM-ASSYM4-01
| 120 |
M7119
|
M7119-CMC responded with incorrect material number confirmation information
|
Abnormal personnel operation
|
The solution for M7119-CMC responding with incorrect material number confirmation information is to review and double-check the material number being entered, ensure it follows the correct format, and try resetting the device or running material verification checks.
|
KM-ASSYM5-05
| 6 |
M75
|
M75-Start detecting that there is material in the work area, please select the work area status
|
Abnormal personnel operation
|
The solution for the M75-Start error is to select the work area status as "Clear" before starting the machine. If the work area is not clear, the machine will not start and will display this error message.
|
KM-ASSYM5-05
| 11 |
M80
|
M80-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X14)
|
Abnormal personnel operation
|
The solution for the error M80-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X14) involves resetting the emergency stop button and ensuring that the safety door is closed before starting the machine
|
KM-ASSYM5-05
| 13 |
M82
|
M82-Please press the reset button before starting the automatic process
|
Abnormal personnel operation
|
The solution to the M82 error described as "Please press the reset button before starting the automatic process" is to press the reset button and then restart the device or application that is producing the error. This will often clear any corrupted files or
|
KM-ASSYM5-05
| 14 |
M83
|
M83-The device has not returned to the origin, please execute the device to return to the origin first
|
Abnormal personnel operation
|
The solution to the M83 error is to perform a device initialization or power cycle by turning off the radio and then back on to reset the device's location and return it to its starting point.
|
KM-ASSYM5-05
| 15 |
M84
|
The communication connection between M84-PLC1 and PLC2 is interrupted
|
Machine communication abnormality
|
The solution for the error described as "The communication connection between M84-PLC1 and PLC2 is interrupted" may involve checking the communication protocols, ensuring proper termination of the connection, checking the modems and communication cards,
|
KM-ASSYM5-05
| 17 |
M86
|
M86-Front buffer conveyor belt feeding operation timeout
|
Organizational Abnormality
|
The solution for the error M86-Front buffer conveyor belt feeding operation timeout is to clean the belt, tighten any loose connections, and ensure proper alignment between components. If the issue persists, check for blockages and repair or replace
|
KM-ASSYM5-05
| 18 |
M87
|
M87-Front buffer conveyor belt discharging operation timeout
|
Organizational Abnormality
|
The solution for the M87-Front buffer conveyor belt discharging operation timeout error could involve checking the connection between the conveyor belt and the motor, ensuring the belt speed is appropriate, and verifying that there are no obstructions in
|
KM-ASSYM5-05
| 19 |
M88
|
M88-Work area inlet conveyor belt operation timeout
|
Organizational Abnormality
|
The solution for the M88-Work area inlet conveyor belt operation timeout error could involve adjusting the conveyor belt speed, updating or replacing the equipment, or contacting the manufacturer for assistance. Regular maintenance can also help prevent this error
|
KM-ASSYM5-05
| 20 |
M89
|
M89-Work area discharging conveyor belt operation timeout
|
Organizational Abnormality
|
The solution to the M89-Work area discharging conveyor belt operation timeout error typically involves cleaning the belt and belt feeder, removing blockages, and adjusting the conveyor speed. If the error persists, you may need
|
KM-ASSYM5-05
| 21 |
M90
|
M90-Rear buffer conveyor belt feeding operation timeout
|
Organizational Abnormality
|
Solution to M90-Rear buffer conveyor belt feeding operation timeout error is to increase the dwell time or use a higher-capacity buffer to allow the belt more time to feed the product. If the error persists, ensure that the belt
|
KM-ASSYM5-05
| 22 |
M91
|
M91-Rear buffer conveyor belt discharging operation timeout
|
Organizational Abnormality
|
The solution for the M91-Rear buffer conveyor belt discharging operation timeout error may involve several troubleshooting steps. These steps could include checking the conveyor belt’s condition; enabling or disabling the rear buffer convey
|
KM-ASSYM5-05
| 23 |
M92
|
M92-The operation of the left label discharging machine has timed out, please check the label discharging machine
|
Electronic control abnormality
|
The solution for the M92 error is recommended to check the label discharging machine for an issue preventing it from functioning properly, or contact technical support for further assistance.
|
KM-ASSYM5-05
| 24 |
M93
|
M93-The operation of the right label dispensing machine has timed out, please check the label discharging machine
|
Electronic control abnormality
|
The solution for the M93 error is to check the label discharging machine and ensure that it is functioning properly. The issue could be caused by a paper jam or other problem with the machine, which is delaying the dispensing process and
|
KM-ASSYM5-05
| 25 |
M94
|
M94- Abnormal rise of blocking cylinder in work area (X20)
|
Organizational Abnormality
|
The M94 error code indicates a problem with the blocking cylinder in the work area. To fix this, follow these steps: Check that all the blocking cylinders are functioning properly and that no obstacles are blocking the work area. If
|
KM-ASSYM5-05
| 26 |
M95
|
M95- Abnormal descent of blocking cylinder in work area (X21)
|
Organizational Abnormality
|
The solution for M95- Abnormal descent of blocking cylinder in work area (X21) error involves checking the hydraulic cylinder, adjusting the screws and bushings, replacing or repairing the worn parts,
|
KM-ASSYM5-05
| 27 |
M96
|
M96- Abnormal rise of jacking cylinder in work area (X22)
|
Organizational Abnormality
|
The solution for the M96 error code "Abnormal rise of jacking cylinder in work area (X22)" would typically involve performing a thorough inspection of the equipment to identify any faulty components or loose connections. Once the cause of
|
KM-ASSYM5-05
| 28 |
M97
|
M97 - Abnormal descent of jacking cylinder in work area (X23)
|
Organizational Abnormality
|
The solution for M97 Abnormal descent of jacking cylinder in work area (X23) is to inspect the jacking cylinder and its components for damage or defects, and ensure proper maintenance and safe operation of the jacking
|
KM-ASSYM5-05
| 35 |
M104
|
M104-X axis servo NO readly & ERROR (X10)
|
Electronic control abnormality
|
The solution for the M104-X axis servo NO readly and ERROR (X10) can vary depending on the specific issue, but it often involves checking the connections between the servo and the motherboard, confirming that
|
KM-ASSYM5-05
| 36 |
M105
|
M105-X axis left limit abnormality (X5)
|
Electronic control abnormality
|
The M105 error occurs when the X-axis left limit is exceeded during printing, usually resulting from a print bed issue or a loose cable connection. To solve this error, you can adjust the bed leveling, check for loose connections
|
KM-ASSYM5-05
| 37 |
M106
|
M106-X axis right limit abnormality (X4)
|
Electronic control abnormality
|
The solution for the error "M106-X axis right limit abnormality (X4)" usually involves adjusting the position of the print bed or the extruder to ensure that the X-axis is not touching the right limit
|
KM-ASSYM5-05
| 38 |
M107
|
M107-X axis return to origin time timeout
|
Electronic control abnormality
|
The error M107-X axis return to origin timeout indicates that the machine is experiencing a timing issue while returning to the origin position. This error typically occurs when there is a problem with the encoder or motor that is causing the axis to
|
KM-ASSYM5-05
| 39 |
M108
|
M108-Y axis servo NO readly & ERROR (X11)
|
Electronic control abnormality
|
The solution for the error described as M108-Y axis servo NO readly & ERROR (X11) is to reset the printer's configuration or check for any servo problems or update the printer software. If the issue
|
KM-ASSYM5-05
| 40 |
M109
|
M109-Y axis front limit abnormality (X7)
|
Electronic control abnormality
|
The M109-Y axis front limit abnormality (X7) error occurs when the Y-axis position or velocity exceeds the front limit, which can be caused by a damaged Y-axis motor or a faulty limit switch
|
KM-ASSYM5-05
| 42 |
M111
|
M111-Y axis return to origin time timeout
|
Electronic control abnormality
|
The solution for M111-Y axis return to origin time timeout error is to increase the timeout value or configure the printer to use a faster communication speed. This can be done using the G901 command or by modifying the printer
|
KM-ASSYM5-05
| 43 |
M112
|
M112-Nozzle 1 return to origin time timeout
|
Electronic control abnormality
|
The solution for error M112 could be to adjust the nozzle control parameters such as rate of speed and acceleration/deceleration or to upgrade the firmware of the printer. Additionally, you could also reduce the print speed
|
KM-ASSYM5-05
| 45 |
M114
|
M114-Nozzle 1 manual positioning running time timeout
|
Electronic control abnormality
|
The M114-Nozzle 1 manual positioning running time timeout error indicates that the system took too long to respond to a manual positioning request for Nozzle 1. To resolve this issue, check the nozzle
|
KM-ASSYM5-05
| 46 |
M115
|
M115-Nozzle 1 automatic positioning running time timeout
|
Electronic control abnormality
|
The solution for M115-Nozzle 1 automatic positioning running time timeout error is to check the printer's settings and configuration to ensure that the printer is set up to wait long enough for the automatic positioning process to complete
|
KM-ASSYM5-05
| 47 |
M116
|
M116-Nozzle 1 vacuum abnormality (PLC2-X4)
|
Electronic control abnormality
|
The solution for the error M116-Nozzle 1 vacuum abnormality (PLC2-X4) typically involves checking for blockages or leaks in the nozzle and vacuum system, ensuring proper air supply,
|
KM-ASSYM5-05
| 49 |
M118
|
M118-Nozzle 2 return to origin time timeout
|
Electronic control abnormality
|
The M118 error occurs when the nozzle does not return to its original position within a specified time limit. To resolve this issue, you may need to adjust the nozzle's positioning parameters or limit the print speed.
|
KM-ASSYM5-05
| 50 |
M119
|
M119-Z axis is out of step when nozzle 2 is running, please perform origin return
|
Electronic control abnormality
|
This error is related to the Z-axis being out of step during printing while Nozzle 2 is running. To resolve this, an origin return must be performed to reset the printer's coordinates and ensure smooth operation.
|
KM-ASSYM5-05
| 51 |
M120
|
M120-Nozzle 2 manual positioning running time timeout
|
Electronic control abnormality
|
The M120 error may occur when the manual positioning of Nozzle 2 exceeds the prescribed time limit. This could be due to several reasons like slow printing speeds, insufficient ink or paper supply, or a software gl
|
KM-ASSYM5-05
| 53 |
M122
|
M122-Nozzle 2 vacuum abnormality (PLC2-X5)
|
Electronic control abnormality
|
The M122 error code indicates a vacuum abnormality in Nozzle 2 of a PLC2-X5 machinery. The solution depends on the root cause, but it could involve cleaning the nozzle or replacing a damaged
|
KM-ASSYM5-05
| 54 |
M123
|
M123-Nozzle 2 failed to pick up materials several times in a row
|
Electronic control abnormality
|
The solution to the error M123-Nozzle 2 failed to pick up materials several times in a row is to check for any blockages or clogs in the nozzle, and to verify that the material you are trying
|
KM-ASSYM5-05
| 56 |
M125
|
M125-Suction nozzles 1&2 have not reached the safe height when the slide is running (PLC2-X0, X1)
|
Electronic control abnormality
|
The solution to the M125-Suction nozzles 1&2 have not reached the safe height error when the slide is running (PLC2-X0, X1) may involve adjusting the nozzle height
|
KM-ASSYM5-05
| 57 |
M126
|
M126-Nozzle 1&2 Z axis origin sensor abnormality (PLC2-X0, X1)
|
Sensor abnormality
|
The solution for the M126 error involving nozzle 1&2 Z axis origin sensor abnormality in a PLC2-X0, X1 system might require calibration, maintenance, or replacement of the Z axis origin
|
KM-ASSYM5-05
| 58 |
M127
|
M127-Nozzle 1 does not sense the Z1 axis origin sensor (PLC2-X0)
|
Sensor abnormality
|
The solution to the M127 error "Nozzle 1 does not sense the Z1 axis origin sensor (PLC2-X0)" would involve troubleshooting the Z1 axis sensor on PLC2-X0
|
KM-ASSYM5-05
| 60 |
M129
|
M129-Product Marker 1 point photo failed
|
Visual abnormality
|
The solution for M129-Product Marker 1 point photo failed error is to check if the product marker has been moved or deleted from its original location. If the marker is missing, you can manually add it back by following the steps
|
KM-ASSYM5-05
| 61 |
M130
|
M130-Product Marker 2 point photo failed
|
Visual abnormality
|
Unfortunately, there is no one solution for the M130-Product Marker 2 point photo failed error as it can be caused by various issues such as incorrect photo alignment, lighting conditions, and software compatibility. To resolve it, try adjust
|
KM-ASSYM5-05
| 62 |
M131
|
M131-Nozzle 1 failed to take pictures with the camera 3 times in a row
|
Visual abnormality
|
The solution for M131-Nozzle 1 failed to take pictures with the camera 3 times in a row may require a faulty camera or nozzle, check connections, software updates, or replace the malfunctioning component
|
KM-ASSYM5-05
| 64 |
M133
|
M133-Failed to take photos of materials on the left tray three times in a row
|
Visual abnormality
|
The solution to the error M133-Failed to take photos of materials on the left tray three times in a row could involve troubleshooting steps such as checking camera settings, ensuring proper lighting, cleaning the camera lens, or restarting
|
KM-ASSYM5-05
| 65 |
M134
|
M134-Failed to take photos of materials on the right tray three times in a row
|
Visual abnormality
|
The M134 error occurs when the machine is unable to take photos of materials on the right tray three times in a row. To solve this error, you can check if the tray is in the correct position and if there are any obstructions
|
KM-ASSYM5-05
| 66 |
M135
|
M135-Up camera & lower camera failed to capture images
|
Visual abnormality
|
The solution for M135-Up camera & Lower camera failed to capture images error can be found by checking the settings of the cameras, ensuring that the memory card is properly formatted and inserted, checking the battery life, and restarting the
|
KM-ASSYM5-05
| 68 |
M137
|
M137-CCD reads PLC product detection request signal timeout (D207=1-12)
|
Electronic control abnormality
|
The error described as M137-CCD reads PLC product detection request signal timeout (D207=1-12) occurs when the PLC does not detect the presence of a product after a specified time due to a
|
KM-ASSYM5-05
| 71 |
M140
|
M140-CCD reads PLC single-round completion signal timeout (read D720=1)
|
Electronic control abnormality
|
The solution for the error M140-CCD reads PLC single-round completion signal timeout (read D720=1) is to first verify that the PLC timer parameter is set correctly to match the time required for the
|
KM-ASSYM5-05
| 72 |
M141
|
M141-CCD reads the PLC right material picking completion signal timeout (read D228=1)
|
Electronic control abnormality
|
The M141-CCD error occurs when the PLC fails to receive a material picking completion signal from the CCD sensor for a set timeout period. To resolve this issue, you can check the CCD sensor and cable connections, adjust
|
KM-ASSYM5-05
| 73 |
M142
|
M142-CCD reads the CCD photo request signal under the PLC and times out (read D230=1)
|
Electronic control abnormality
|
It appears that M142-CCD and D230 are related to a photo request signal under a PLC. The error message suggests that the PLC is not able to read the signal properly and times out. Without more specific
|
KM-ASSYM5-05
| 75 |
M144
|
Assembly point is out of range
|
Visual abnormality
|
The Assembly point is out of range error occurs when the program tries to use an invalid address in an instruction. The solution is to ensure that the address being used is within the allowed range, typically 0x00000000
|
KM-ASSYM5-05
| 76 |
M145
|
The picking point is out of range
|
Visual abnormality
|
The error "The picking point is out of range" occurs when the coordinates of the picking point are invalid. To solve this error, make sure that the picking point's coordinates fall within the valid range and try again.
|
KM-ASSYM5-05
| 77 |
M146
|
M146-PLC timed out waiting for the CCD to reply with the result of taking the material and taking pictures (read D202=100 or D204=100)
|
Visual abnormality
|
The solution for the M146-PLC timed out waiting for the CCD to reply with the result of taking the material and taking pictures could be to check the communication settings between the PLC and CCD and ensure that they are
|
KM-ASSYM5-05
| 78 |
M147
|
M147-PLC timed out waiting for CCD to reply to the Mark point photo result (D206=100)
|
Visual abnormality
|
The solution for M147-PLC timeout error is to increase the timeout duration for the CCD in the PLC system. The timeout duration can be set in the PLC system's configuration, usually in the communication settings. Incre
|
KM-ASSYM5-05
| 79 |
M148
|
M148-PLC timed out while waiting for CCD to reply with product detection and photographing results (D207=100)
|
Visual abnormality
|
M148-PLC timed out while waiting for CCD to reply with product detection and photographing results (D207=100) is an error message indicating that the control system (PLC) is unable to
|
PODLABEL
| 1 |
M7000
|
M7000-Start detecting that there is material in the work area, please confirm the status of the work area
|
Abnormal personnel operation
|
The solution for the M7000-Start error is to visually inspect the work area and physically remove any material that may be present. Confirm the status of the work area before starting production again.
|
PODLABEL
| 18 |
M7017
|
M7017-Equipment model setting is abnormal, please set the model
|
Abnormal personnel operation
|
The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a
|
PODLABEL
| 19 |
M7018
|
M7018-Please press the reset button before starting the automatic process
|
Abnormal personnel operation
|
M7018 error usually occurs when the printer's automatic process fails to initiate properly. The solution is to press the reset button or perform a power cycle to restart the printer.
|
PODLABEL
| 20 |
M7019
|
M7019-The device has not returned to the origin, please execute the device to return to the origin first
|
Abnormal personnel operation
|
The solution to the M7019 error is to first execute the device to return to its origin before attempting any further actions. This error occurs when a device is not properly synchronized with its origin, and it requires the device to be returned to
|
KM-ASSYM4-03
| 6 |
M7007
|
Alarm: pressing position blocked_sensor double lights
|
Organizational Abnormality
|
There are several possible causes for this error, including a malfunctioning light sensor or an issue with the camera. However, the most common solution is to clean the affected area thoroughly and try again. If the problem persists, contact the manufacturer or
|
KM-ASSYM4-03
| 8 |
M7009
|
Alarm: pad pushes out cylinder 1_moving position alarm
|
Organizational Abnormality
|
The solution for the "pad pushes out cylinder 1_moving position alarm" error would likely involve checking the wiring and making sure that the pad and cylinder are properly aligned. It is recommended to contact a professional mechanic if
|
KM-ASSYM4-03
| 32 |
M7044
|
Alarm: During initialization, the assembly line materials were not cleared.
|
Abnormal personnel operation
|
To resolve the "Alarm: During initialization, the assembly line materials were not cleared." error, ensure that all materials are properly placed and cleared from the assembly line before beginning operations. This can prevent any potential issues during the initial setup of the production
|
KM-ASSYM4-03
| 33 |
M7045
|
Alarm: initial startup, there is material in the assembly line
|
Abnormal personnel operation
|
To fix the error described as Alarm: initial startup, there is material in the assembly line, you'll need to identify the source of the material and clear it from the assembly line. This may require adjusting your manufacturing processes or stopping production
|
KM-ASSYM5-05
| 80 |
M149
|
M149-PLC timed out while waiting for CCD reply to the camera photo taking result (D230=100 or 101)
|
Visual abnormality
|
The error M149-PLC timed out while waiting for CCD reply to the camera photo taking result indicates that the PLC is waiting for a response from the CCD camera but is not receiving a reply. This error can be
|
KM-ASSYM5-05
| 81 |
M150
|
M150-PLC timed out while waiting for CCD to send the retrieval command (D208=1&2&3&4)
|
Visual abnormality
|
The solution to M150-PLC timed out while waiting for CCD to send the retrieval command could be to increase the timeout value in the PLC programming or to add a delay between the CCD command and the PLC
|
KM-ASSYM5-05
| 82 |
M151
|
M151-PLC timed out waiting for CCD to send the pickup coordinates of nozzle 1&2 (D210&D220)
|
Visual abnormality
|
The solution for the M151-PLC error is to increase the timeout value in the PLC program for the CCD camera to send the pickup coordinates of nozzles 1 and 2.
|
KM-ASSYM5-05
| 83 |
M152
|
M152-PLC timed out waiting for CCD to send nozzle 1&2 discharging coordinates (D700&D710)
|
Visual abnormality
|
The solution for error M152-PLC timed out waiting for CCD to send nozzle 1&2 discharging coordinates (D700&D710) could involve adjusting the timing settings between
|
KM-ASSYM5-05
| 4 |
M73
|
M73-The operation of the right label dispensing machine has timed out, please check the label discharging machine
|
Electronic control abnormality
|
To solve the issue of M73-timed out error in the label dispensing machine, first, the user should check the label discharging machine to ensure that it is functioning correctly. If issues are found, troubleshoot them before
|
KM-ASSYM5-05
| 12 |
M81
|
M81-Equipment model setting is abnormal, please set the model
|
Abnormal personnel operation
|
To resolve the error M81-Equipment model setting is abnormal, please set the model, follow these steps:
1. Identify the equipment in question.
2. Determine the correct model number for the equipment.
|
KM-ASSYM5-05
| 41 |
M110
|
M110-Y axis rear limit abnormality (X6)
|
Electronic control abnormality
|
The solution to the M110-Y axis rear limit abnormality (X6) error may involve adjusting the rear limit switch to ensure it is properly aligned with the rear of the bed. If it is still inaccurate after
|
KM-ASSYM5-05
| 44 |
M113
|
M113-Z axis is out of step when nozzle 1 is running, please perform origin return
|
Electronic control abnormality
|
The error M113-Z axis is out of step when nozzle 1 is running, indicating a problem with the Z-axis position of the printer. A possible solution is to perform an origin return, which involves resetting the
|
KM-ASSYM5-05
| 48 |
M117
|
M117-Nozzle 1 failed to pick up materials several times in a row
|
Electronic control abnormality
|
The solution for the error described as M117-Nozzle 1 failed to pick up materials several times in a row is to check the nozzle for clogs or jams, clean the nozzle, verify that the
|
KM-ASSYM5-05
| 52 |
M121
|
M121-Nozzle 2 automatic positioning running time timeout
|
Electronic control abnormality
|
The error M121-Nozzle 2 automatic positioning is likely occurring because the nozzle is not sensing the correct position or because there is a connectivity issue between the nozzle and the printer's computer.
|
KM-ASSYM5-05
| 55 |
M124
|
M124-Nozzle 1 or Nozzle 2 initialization time timeout
|
Electronic control abnormality
|
The solution for M124-Nozzle initialization time timeout error could be resetting the printer, updating the firmware or printer settings, ensuring adequate printer maintenance, or utilizing the printer's diagnostic functionality to determine and resolve the issue.
|
KM-ASSYM5-05
| 70 |
M139
|
M139-CCD times out when reading the PLC material retrieval request signal (read D209=1 or D219=1)
|
Electronic control abnormality
|
The solution for the "M139-CCD times out when reading the PLC material retrieval request signal (read D209=1 or D219=1)" error is to check the signal wiring and ensure
|
KM-ASSYM5-05
| 74 |
M143
|
M143-CCD times out when reading the PLC material picking and photographing request signal (read D202=1 or D204=1)
|
Visual abnormality
|
The solution for the M143-CCD times out error when reading the PLC material picking and photographing request signal is to increase the timeout value for the PLC interface in the device driver settings. You can try to increase the timeout
|
KM-ASSYM5-05
| 63 |
M132
|
M132-Nozzle 2 failed to take pictures with the camera 3 times in a row
|
Visual abnormality
|
There could be several reasons for this error, including issues with camera hardware or software, connectivity problems, incorrect settings, or problems with the printer's firmware or drivers. The best solution would be to troubleshoot the camera and printer settings
|
KM-ASSYM5-05
| 67 |
M136
|
The connection between M136-CCD and PLC failed
|
Visual abnormality
|
The solution for the error "The connection between M136-CCD and PLC failed" would be to check the connections between the two devices, ensure that they are properly configured and functioning properly, and if necessary, troubleshoot the
|
KM-ASSYM5-05
| 69 |
M138
|
M138-CCD reads the PLC Marker point photo request signal timeout (D206=1)
|
Visual abnormality
|
M138-CCD reads the PLC Marker point photo request signal timeout (D206=1) indicates that the marker point photo request did not receive a response from the PLC. This could be due to communication issues
|
KM-ASSYM5-05
| 59 |
M128
|
M128-Nozzle 2 does not sense the Z2 axis origin sensor (PLC2-X2)
|
Sensor abnormality
|
The solution to the M128 error "Nozzle 2 does not sense the Z2 axis origin sensor (PLC2-X2)" usually involves checking and resetting the Z2-axis origin sensor or troubleshooting
|
KM-ASSYM5-06
| 1 |
M7000
|
M7000-Thermal paste is about to run out, please prepare thermal paste
|
Abnormal personnel operation
|
This error message usually appears on a printer to notify the user that the thermal paste is running out and the user needs to replace it before the printer will continue to function properly. The printer uses thermal paste to help maintain a consistent temperature of the printer head
|
KM-ASSYM5-06
| 2 |
M7001
|
M7001-Start detecting that there is material in the work area, please select the work area status
|
Abnormal personnel operation
|
The solution for the error "M7001-Start detecting that there is material in the work area, please select the work area status?" is to ensure that the appropriate work area is selected before starting the processing by either re-routing
|
KM-ASSYM5-06
| 17 |
M7016
|
M7016-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X22)
|
Abnormal personnel operation
|
The solution for the error described as M7016-EMO&&DOOR is on, is to check the safety door and emergency stop switch (X22). If either of these components is faulty, it can cause the error
|
KM-ASSYM5-06
| 18 |
M7017
|
M7017-Equipment model setting is abnormal, please set the model
|
Abnormal personnel operation
|
The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a
|
KM-ASSYM5-06
| 19 |
M7018
|
M7018-The automatic process is not reset before starting, please press the reset button first
|
Abnormal personnel operation
|
The solution to the M7018 error is to press the reset button first before attempting to start the automatic process. Once the reset is complete, the process should restart without any issues.
|
KM-ASSYM5-06
| 20 |
M7019
|
M7019-The device abnormality has not been eliminated before automatic startup. Please eliminate the device abnormality first
|
Abnormal personnel operation
|
The solution for M7019 error is to first identify and eliminate the device abnormality before automatic startup. This can be achieved through manually testing the device and resetting it if necessary.
|
KM-ASSYM5-06
| 21 |
M7020
|
M7020-The equipment slide table has not returned to the origin, please execute the slide table return to the origin first
|
Abnormal personnel operation
|
The solution for the M7020 error is to execute the slide table return to the origin first before attempting any other operation on the equipment.
|
KM-ASSYM5-06
| 33 |
M7032
|
M7032-The feeding operation of the front Buffer conveyor belt times out, please check whether there is any jamming between the upper and lower reaches of the machine
|
Organizational Abnormality
|
The error M7032 indicates that the feeding operation of the front buffer conveyor belt has timed out, which may be due to jamming between the upper and lower reaches of the machine. The solution to this issue is to check for
|
KM-ASSYM5-06
| 34 |
M7033
|
M7033-The discharging operation of the front buffer conveyor belt times out, please check whether the machine is jammed
|
Organizational Abnormality
|
The M7033 error message indicates that the front buffer conveyor belt is experiencing a discharging operation timeout. This occurs when the machine is jammed and prevents it from releasing its contents. To resolve this issue, please inspect the belt
|
KM-ASSYM5-06
| 35 |
M7034
|
M7034-The feeding conveyor belt in the work area has run timeout, please check whether the machine is jammed
|
Organizational Abnormality
|
The solution for the error described as M7034 is to check if the feeding conveyor belt is jammed. If it is, troubleshoot the problem and clear any obstructions. If the problem persists, seek technical support from
|
KM-ASSYM5-06
| 36 |
M7035
|
M7035-The discharge conveyor belt in the work area has run timeout, please check whether the machine is jammed
|
Organizational Abnormality
|
The solution for M7035 error is to manually check if the discharge conveyor belt is jammed by inspecting the belt and clearing any obstacles or debris. If the problem persists, it may require maintenance or repair of the
|
KM-ASSYM5-06
| 37 |
M7036
|
M7036-The feeding operation of the rear buffer conveyor belt has timed out, please check whether the machine is jammed
|
Organizational Abnormality
|
The solution for the M7036 error is to check the rear buffer conveyor belt for jams or obstructions. If the belt is jammed, clear the obstruction and try running the belt again. If the belt continues to jam
|
KM-ASSYM5-06
| 38 |
M7037
|
M7037-The discharging operation of the rear buffer conveyor belt times out, please check whether there is any jamming between the upper and lower reaches of the machine
|
Organizational Abnormality
|
M7037 error occurs when the discharging operation of the rear buffer conveyor belt times out and there is jamming between the upper and lower reaches of the machine. The solution is to clear any jamming in the machine, ensuring
|