<|begin▁of▁sentence|> ### Instruction: umass_enum-3-FAILED_TO_ACCESS_KSH_REPARTITION ### Response: (Severity: 3), (Category: PLATFORM), (Description: Some existing eUSB may have wrong FS or partitions. Check if need to reformat the eUSB. This message will get printed if there is failure in accessing the Ksh to repartition eUSB.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PCIER-0-PCIE_FAB_FATAL_ACCESS_ERR ### Response: (Severity: 0), (Category: PLATFORM), (Description: A PCIE (fabric block) access error was detected for controller Card. The error prevents this card to perform some vital tasks making it unusable), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CLNS-3-SOCK_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An operation failed during socket initialisation.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PLACED-3-NOTIF_REGN ### Response: (Severity: 3), (Category: OS), (Description: Unable to register for event_item with sysdb.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the <CmdBold>show tech-support placed<noCmdBold> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the <CmdBold>show tech-support placed<noCmdBold> output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the <CmdBold>show tech-support sysdb<noCmdBold> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the <CmdBold>show tech-support sysdb<noCmdBold> output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_11_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location <loc>', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: QNET-6-CLOSE_ENET_DEVICE_INFO ### Response: (Severity: 6), (Category: OS), (Description: Faliure to close the connection to ethernet server.), (Recommended Action: Informational message) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: OSPF-6-DBEXIST ### Response: (Severity: 6), (Category: ROUTING), (Description: OSPF has an invalid duplicate copy of an LSA, which could lead to a memory leak.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the <CmdBold>show tech-support<noCmdBold> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the <CmdBold>show tech-support<noCmdBold> output, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the additional following commands: - show ospf database - show ospf <process-name> trace all) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: AIB_CLIENT-4-ADJ_SANITY_CHK ### Response: (Severity: 4), (Category: ROUTING), (Description: AIB entries have somehow set REMOTE_FLAG for TX ADJ. This should not happen - remote flag should only be set for RX ADJ.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: OPTICS_MODULE-2-DEV_OPTICS_SUPPORTED_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: An supported error was detected during optics initialization. This error is reported when the optics type can not be determined or it is not supported on the platform. The optics is the pluggable optics on the line cards.Optics initialization may happen when linecard boots up, optics OIR and line card process restart. The optics will not be enabled if an optics supported error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller <i/f> internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the optics with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location <loc>', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: NCS4K_4H_OPW_QC2-3-THRD_ACCESS_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: THRD Access failed), (Recommended Action: None.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-NPU_0_FC_OOS_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress flow control out-of-sync on NPU-0 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SPA-6-OPTICS_INSERTION ### Response: (Severity: 6), (Category: L2), (Description: Optics module has been inserted. %d - indicates the bay number), (Recommended Action: None. This is an informational message only.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PLACED-3-PTHREAD_DETACH ### Response: (Severity: 3), (Category: OS), (Description: PlaceD daemon was unable to detach the thread. Recovery occurs with automatic process restart.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the <CmdBold>show tech-support placed<noCmdBold> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the <CmdBold>show tech-support placed<noCmdBold> output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PKG-7-BAD_PIE_FORMAT ### Response: (Severity: 7), (Category: INSTALL), (Description: The PIE file is in an obsolete format or is unknown.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-UNKNOWN_BOOT_REQ_MSG_VER ### Response: (Severity: 3), (Category: PLATFORM), (Description: Shelf manager received a version of boot request message that it cannot support.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_7_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power greater than or equal to the high Tx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location <loc>', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: RSVP-5-MAM_MAX_RES_BW_NO_VALUE_DEPRECATE_NOTICE ### Response: (Severity: 5), (Category: ROUTING), (Description: Interface bandwidth mam max-reservable-bw is being configured without \ specifying a value. This is not supported in XML and YANG models.), (Recommended Action: Use the 'mam [percentage] max-reservable-bw <Value>'.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-PKT_LEN_ERR_1_FIA_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet length error from FIA for NPU-1 on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'area default-cost' command in OSPF? ### Response: The 'area default-cost' command is used on an Area Border Router (ABR) to specify the cost of the default route that it generates into a stub or NSSA area. By default, the cost is 1. Increasing this value makes the default route less preferred. This is useful for controlling how traffic from the stub or NSSA area exits the area when there are multiple ABRs. <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PLAT_DISC-6-PAK_MEM_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Find out physical memory information from SYSPAGE. If more memory is found than our defined minimum MIN_RESERVED_MEM, then a scaling factor is created to scale the number of packets, particles, etc, upward. Packet memory information like size, starting, scaling are shown), (Recommended Action: Information message only no action is required.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: NVRAM-6-OPENERROR ### Response: (Severity: 6), (Category: MEDIA), (Description: Check the state of the device pointed by path. Device may be inaccessible.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: LDA-3-OPTICS_FPD_UPGRADE_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Unable to complete FPD upgrade for the Optics due to an internal software or Hardware error. The error message describes the error.), (Recommended Action: Move the Optics to Laser Shut State before performing FPD Upgrade and do the Optics OIR or MPA reload to recover the Optics from Fault state. If the issue occurs under other conditions, then copy the error message exactly as it appears on the screen and collect console log and - sh platform - sh install summary - sh version - show tech-support ethernet interfaces.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-ASIC_FMEA ### Response: (Severity: 3), (Category: FABRIC), (Description: Asic FMEA Fault Report), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: LTRACE_CONFIG-7-ERR_MUTEX_INIT ### Response: (Severity: 7), (Category: OS), (Description: A internal mutex operation has failed. This is a bug.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_14_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location <loc>', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: FCA-2-RESET_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected an error. Device is not coming out of reset.), (Recommended Action: Please contact technical support If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: FAB-5-ltrace_init_error ### Response: (Severity: 5), (Category: PLATFORM), (Description: fpoe: ltrace_init2 for errors trace failed.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_0_ERR3_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 0 ran into error-3 on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_WAVL_INIT ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an unexpected error which prevents it from functioning. This error may be caused by low memory resources. The process will abort and be restarted in an attempt to recover.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: BCDLTLV-6-MSG_GENERIC_ERROR ### Response: (Severity: 6), (Category: OS), (Description: BCLS TLV processing hit some error condition.), (Recommended Action: Contact support.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CFM-3-ENGINE_TIMER ### Response: (Severity: 3), (Category: L2), (Description: An error occurred while processing the engine thread timer wheel. This may cause CCMs not to be sent, or peer MEPs not to time out after the configured loss time.), (Recommended Action: The process may recover after 60s. If the problem persists, it may be possible to recover by restarting the 'cfmd' process on the node where the problem occurred.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_EVC_CREATE ### Response: (Severity: 4), (Category: L2), (Description: PPP MA failed to create a connection to an essential service during initialization. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: FAB_SVR_HFR-7-ERR_EVENT_CONN_NOTIFY ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to register event handler for disconnection or connection error event. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: INSTALL-6-FILE_SYSTEM_SWITCHOVER_PERFORMED_PRE_RELOAD ### Response: (Severity: 6), (Category: INFRA), (Description: When applying some versions of software, it may be necessary to update the file system to use the new software before a reload is performed. Any processes that were already running, will continue to use the old software until the reload has been performed. Any processes that are (re-)started will use the new software and meta-data. The new software may be incompatible with the older software, and so any communication between new processes and old processes cannot be guaranteed to be compatible, increasing the chances of an abnormal restart. It is recommended to not perform any operations, via any manageability interface, until the system has reloaded - unless specifically requested.), (Recommended Action: Do nothing, until the system has reloaded.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: IPV6_ND-3-ERR_MPLS_ATTR_GET ### Response: (Severity: 3), (Category: IP), (Description: Cannot determine whether MPLS is enabled or not on the interfaces), (Recommended Action: Restart IPv6 ND) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: OPTICS-6-TRANSCEIVER_ENABLED ### Response: (Severity: 6), (Category: L2), (Description: This informational message indicates that the optic interface module was enabled on the given interface after 'no shut' was applied to the optical controller.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-1-FC_OIR_ALERT ### Response: (Severity: 1), (Category: PLATFORM), (Description: 1) An alarm has occured. The Fan Controller card has been removed. 2) A previously occured alarm has been cleared. The Fan Controller Card has been re-inserted.), (Recommended Action: Two possibilities to this message. 1) An alarm has occured : Insert the Fan Controller Card. 2) A previously occured alarm has been cleared : *None*) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: AAAD-2-CRITICAL_ERROR ### Response: (Severity: 2), (Category: MGBL), (Description: A critical error was encountered. The failure of this can be critical to general system operation. If the same error is seen more than 5 times, contact Cisco TAC support because a reboot of the node may be required.), (Recommended Action: Provide the message details to Cisco Support representative.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: IKEV2-7-VERIFY_APPLY ### Response: (Severity: 7), (Category: OS), (Description: A sysdb verify/apply callback information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SLICE_MGR_PROXY-3-CAPI_CONNECTION_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Connection to mentioned CAPI service failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-6-DELETE_SHIM_ENTRY ### Response: (Severity: 6), (Category: L2), (Description: Debug Information - Deleting shim info entry for the given interface handle), (Recommended Action: *None*.Informational message only.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: OSPF-4-PAKMAN_EVENT ### Response: (Severity: 4), (Category: ROUTING), (Description: An error has occurred and pak manager sent us an event. If we can't recover from the error (ABORT event), OSPF will exit.), (Recommended Action: This is an indication that error(s) has occurred in pakman No specific actions are required for OSPF.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-TARGET_CFG_LOCKERR ### Response: (Severity: 3), (Category: MGBL), (Description: Config process failed to obtain exclusive lock for this session. Terminate the other open sessions and try again.), (Recommended Action: *SH_TECH*) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: BGP-3-NH_LOCK_RECURSIVE ### Response: (Severity: 3), (Category: ROUTING), (Description: A software error has occurred whilst trying to lock a nexthop entry in the BGP nexthop Table database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: telnet-6-INVALID_ADDRESS ### Response: (Severity: 6), (Category: IP), (Description: 'The call to ip_addr_c_get_v4/v6_best() returned an invalid address'), (Recommended Action: *SH_TECH*) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: FPD-4-WARN ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is a warning message from FPD operation.), (Recommended Action: *NONE*) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-NO_HB_RECEIVED ### Response: (Severity: 4), (Category: PLATFORM), (Description: This indicates that something is wrong in shelfmgr's ability to receive Heart Beats, OR there are simply no cards sending HBs.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_2_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location <loc>', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SCHEMA-7-INTERNAL ### Response: (Severity: 7), (Category: MGBL), (Description: An internal error has occurred in the schema server or library. Some management functions may not operate correctly.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: ISIS-4-REDIST_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: The RIB returned an unexpected error when IS-IS attempted to (de)register for the redistribution of routes in the specified topology and owned by the specified protocol. If this is a registration error then routes from the specified protocol may not be advertised in IS-IS's system LSPs. If this is a deregistration error then IS-IS may receive unnecessary redistribution updates from the RIB but the system LSPs will be correctly generated. The problem may be caused by a low memory condition but is most likely to be an internal programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the IS-IS and/or the RIB processes. *RECUR*.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: QFP_IFM-3-WARN_LIB_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: A failure occured in the CPP IFM Library that may affect the functionality of CPP.), (Recommended Action: *SH_CMD debug controllers pse qfp interface ifm all all * *SH_CMD show controllers pse qfp interface ATM R/S/I/P info * *SH_CMD show controllers pse qfp interface ATM R/S/I/P location < > * *SH_CMD show controllers pse qfp interface ATM R/S/I/P statistics *) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-DP_MUX_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: DP MUX read/write access failure/success), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-2-ENFORCE_GRACE_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature is still enabled after grace period.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_7_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location <loc>', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CHKPT_CLI-7-BAD_BUFFER ### Response: (Severity: 7), (Category: HA), (Description: A NULL pointer was encountered unexpectedly.), (Recommended Action: Collect system log information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: STATSD-3-EVENT_BLOCK ### Response: (Severity: 3), (Category: MGBL), (Description: The event handling function returned an error which could not be handled), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-2-HEADLESS_RSP_DETECTED ### Response: (Severity: 2), (Category: PLATFORM), (Description: This card has stopped receiving heartbeat messages from the RSP. It will therefore reset itself as it can not communicate properly with the RSP.), (Recommended Action: Please collect the following information and contact your Cisco technical support representative. 1. The console output of the active RSP from user login till the end. Please make sure the above error message(s) are included. 2. (admin)#show install trace mbi-hello location <affected location> 3. The output of the following CLI commands:) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PLIM_16P_OC48-3-DEVICE_INTR_CLEAR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The previously reported excessive interrupts condition has been cleared. Interrupt rate limiting has been disabled.), (Recommended Action: No action is required.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: ZTP-3-RELOAD_TIMED_OUT ### Response: (Severity: 3), (Category: INFRA), (Description: Router did not reload within expected duration after image was installed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: ATM_VCCLASS-3-PRODUCER_HDLR ### Response: (Severity: 3), (Category: MGBL), (Description: A failure occurred in the ATM VCCLASS producer handler while processing requests from the consumer.Internal failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: HA_WD-3-WATCHER_THREAD_INIT ### Response: (Severity: 3), (Category: HA), (Description: An error occured when attempting to initialize the cpu watcher thread.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SMS-7-MISSING_NODE_NFN ### Response: (Severity: 7), (Category: SYSDB), (Description: No node down notification was received from the underlying infrastructure for a recent node reload.), (Recommended Action: *SUPPORT*) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: LTRACE_SDT_SHOW-7-NODE_PRINT ### Response: (Severity: 7), (Category: OS), (Description: The show helper was unable to decode a text name for the node id a given trace block containing string data came from. As a result of this, the given trace will not be printable.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTP7 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: EIGRP-3-PEERSEXIST ### Response: (Severity: 3), (Category: ROUTING), (Description: One or more peers exist on an interface which is being deleted and hence the interface may not be deleted completely in EIGRP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: DRP_REDDRV-6-SKIPPING_RESET_STANDBY ### Response: (Severity: 6), (Category: PLATFORM), (Description: Skipping an API reddrv_reset_standby when rmf reference is removed.), (Recommended Action: *NONE*) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: ENVMON_PROXY-3-INVENTORY_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon Proxy process failed to initialize. The System Manager will restart the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, error), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: ETH_SRVR-6-NOT_SUPPORTED_CARD_TYPE_NG ### Response: (Severity: 6), (Category: PLATFORM), (Description: This command is not supported on RSP880/A99-RSP/RP2 card.), (Recommended Action: 'Please use show controllers epm-switch <cmd> location <node>') <|EOT|>
<|begin▁of▁sentence|> ### Instruction: INSTALL-4-NODES_DROPPED ### Response: (Severity: 4), (Category: INFRA), (Description: The install orchestrator has not been able to confirm some nodes after a user requested apply by reload. The ongoing transaction will continue without these nodes. Once the transaction is committed, they will no longer be held down. If they come up with software that does not match that of the active RP, they will then be reimaged.), (Recommended Action: No action is required.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-CPIF_SCSM_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected SCSM multi-bit error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ERR_DLL_UNKNOWN_FUNC ### Response: (Severity: 3), (Category: MGBL), (Description: 'An error occurred when trying to locate the dll function in DLL.'), (Recommended Action: *SH_TECH*) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: What are the main steps performed by the TURBOBOOT process? ### Response: The main steps performed by TURBOBOOT are\n1. Checks the size of the boot device to ensure sufficient space\n2. Cleans up the boot device by deleting old files and directories\n3. Copies the packages from the .vm file to the boot device\n4. Creates necessary directories and links on the boot device\n5. Validates the packages and generates an inventory\n6. Hands over control to the System Manager (sysmgr) to start the IOS XR processes\"\n <|EOT|>
<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-3-SERVER_CONNECT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: A communication problem occurred between the MBI client and server, perhaps because the communications infrastructure is not yet up. The MBI operation in progress will not be carried out.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_4_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location <loc>', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: RIB-3-NH_CLIENT ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occured when trying to clear redist information for a client.), (Recommended Action: *SUPPORT*) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CCC-3-FPGA_MEMORY_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC FPGA detected memory errors . Although its rare to encounter these errors,it impacts CCC FPGA functions. During these errors being experienced by CCC FPGA there are possiblbities of read/write issues to CCC FPGA registers. Also alarms shall be raised by envmon for sensor related accessibilities as CCC FPGA wont be accessible due to errors), (Recommended Action: Try reloading the card using 'hw-module location <> reload'. If multiple card reload operation cannot fix the problem, check if physical OIR can address the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: How does SysDB help achieve high availability in IOS XR? ### Response: SysDB contributes to high availability in several ways\n- Config and persistent state are replicated between active and standby RPs\n- Processes can resynchronize their state from SysDB after a restart\n- Processes can register for notifications to detect config changes and operational state updates\n- Schema enforcement and config validation prevent invalid state from being propagated\"\n <|EOT|>
<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-ATTACH_PORT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath encountered an initialization error), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect <CmdBold>show log location <r/s/i> <NoCmdBold> output, <CmdBold>show controllers dpaa trace all location <r/s/i><NoCmdBold> output and <CmdBold>show memory summary location <r/s/i> <NoCmdBold> from that location.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: BM-5-MLACP_RESYNC_INCONSISTENCY_DISCONNECT ### Response: (Severity: 5), (Category: L2), (Description: A resync failed to solve an inconsistency and so the local device has disconnected.), (Recommended Action: Disable and re-enable mLACP on either the local or the peer device.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: ATMSNMP-3-IFMGR ### Response: (Severity: 3), (Category: SNMP), (Description: A high severity error is encountered. The error relates to an interaction with interface manager.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: RSPP_MA-4-DUP_CREATE_ERR ### Response: (Severity: 4), (Category: SERVICES), (Description: An error has occurred processing an invalid configuration whereby the same service attachment has been configured on two or more interfaces (which should result in both attachments being viewed as failed and moved in to failure state). Packet diversion may now be inconsistent. The error string will give more detail on the type of error that has occurred.), (Recommended Action: For non-resoucre errors, removing the initial misconfiguration may remove this error. If the error is a resource error this will be indicated in the error description given. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: STATSD-3-REGISTRATION_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: Registration of a stats collector with stats server failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_DYNREG-3-AP_UNREGISTER_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered as old attach point data was being unregistered for new data. As a result, the registration for the old data is still activated for this attach point. As this point is would be best to restart the policy_repository to try to clear this inconsistency.), (Recommended Action: Restart the policy_repository process and check for re-occurence of issue If problem persists, the please contact support team) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-META_OPER_WRITE_ERROR ### Response: (Severity: 7), (Category: OS), (Description: An OBFL internal record type write failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_EEC2 ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from EEC2.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-2-ENFORCE_EVAL_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature has been used exceeding evalution period.), (Recommended Action: The customer should either register for license or disable the feature.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_UTIL-7-COLD_RESTART_IGNORED ### Response: (Severity: 7), (Category: HA), (Description: The process has failed to restart multiple times. By design, the process will continue to restart with its existing CDM data.), (Recommended Action: Analyze the restart failure and take appropriate recovery action.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CHUNK-7-PARTIAL ### Response: (Severity: 7), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PCIE-2-PCIE_FAB_FATAL_ACCESS_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PCIE (fabric block) access error was detected for controller Card. The error prevents this card to do traffic switching thereby making it unusable), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: ELO_COMMON-3-SYSMGR_FAIL ### Response: (Severity: 3), (Category: L2), (Description: The process has failed to inform System Manager that it is shutting down. The process will exit anyway, but it is possible that any configuration entered will not cause SysMgr to restart the process. In this case, a timeout will occur when committing configuration, and the config will fail to apply.), (Recommended Action: If configuration fails to apply, recommitting it should correct the issue. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_5_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location <loc>', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SPIO_PD-3-GET_MY_NODE_ROLE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Node role look-up failed. Packet path initialization at RP errored.), (Recommended Action: Restart the spio_ma process. 'process restart spio_ma location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: CMPP-4-LOST_EVENT ### Response: (Severity: 4), (Category: INFRA), (Description: The specified process failed to receive an event that was sent to it.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PLIM-1-ERR_HW_RESET_PLL ### Response: (Severity: 1), (Category: L2), (Description: A hardware error is detected on the PLIM. Software will take action as described in the error message, if not none, to try to recover from the error. The hardware error and the software recovery action will not impact traffic. Device: %s%s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Software action: %s - the action that software will take to try to recover from the error. Recommended user action: %s - recommended action to the user. Possible values: 'none' 'replace XFP' 'PLEASE MANUAULLY RELOAD THE LC AT NEXT MAINTENANCE WINDOW'), (Recommended Action: Take the recommended user action as it is described in the error message.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-UNSUPPORTED_FORMAT ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: XRd currently only supports interface names with the format of a physical, non-satellite interface.), (Recommended Action: Check the format of the interface names in the XR_INTERFACES environment variable.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-BAD_AVPAIR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: QFP_BQS-6-SRTMEMLOW_DECLARE ### Response: (Severity: 6), (Category: L2), (Description: CPP BQS HW schedule resources have dropped below critical threshold.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>
<|begin▁of▁sentence|> ### Instruction: FEA_DLL-3-CHKPT_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: After a process restart, an error was encountered while recovering checkpoint memory/database. The running-configuration and hardware programming may be inconsistent. Problems may be encountered with future configuration changes as well.), (Recommended Action: Try to manually restart pfilter-ea. If the problem/log persists, a reload of the line card is necessary. Get the JID from 'show processes <process-name> location <>' 'process restart JID location <>') <|EOT|>
<|begin▁of▁sentence|> ### Instruction: PUNT-0-FATAL_FAULT ### Response: (Severity: 0), (Category: PLATFORM), (Description: TX PLL inside the FPGA device is not locked.), (Recommended Action: The software is not able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|>