text "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_NODE_STATE_CHANGE ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed on a call to system manager to register to get node state change notification. It's an internal software fatal error. IS-IS process will abort.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAAD-3-INTERNAL ### Response: (Severity: 3), (Category: MGBL), (Description: An unexpected internal error occurred in the aaad.), (Recommended Action: Copy the error message and trace exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SERVER-7-NODE_NAME_FAIL ### Response: (Severity: 7), (Category: OS), (Description: Failed to get the local node name from platform library.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-DIR_IO ### Response: (Severity: 3), (Category: MGBL), (Description: Unable to open/create the directory), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GDOI-3-DBG_ERROR ### Response: (Severity: 3), (Category: OS), (Description: An debug init/fractL call failed and error is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HPI-7-DEBUG_STATUS ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-7-COLD_RESTART ### Response: (Severity: 7), (Category: HA), (Description: Due to too many contiguous failed restarts, sysmgr has requested that the process be restarted without checkpoint data.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TFTP_FS-3-ETIMEOUT_THRESHOLD ### Response: (Severity: 3), (Category: IP), (Description: This message indicates that write to tftp was not completed successfully.), (Recommended Action: tftp_fs process retries for default number of times before timing out and aborting the write to tftp when it is not able to reach the tftp server. Please check the following options to recover from this situation 1> Connectivity to the remote tftp server. If ip connectivity isnot present tftp_fs wont be able to write 2> The number of retries in tftp_fs is configurable. The user can attempt to increase the number of retries and retry the command 3> If the above two options dont help, please please save the file to the disk on the router, compress it and then transfer the file to tftp server. If none of the options help Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-TCAM_PERR ### Response: (Severity: 3), (Category: L2), (Description: A Parity error has occurred in a TCAM device.), (Recommended Action: *SH_CMD sh controllers pse qfp infrastructure tcam resource-manager error parity location *) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_PM_OIR ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when any PM is OIR'ed from satellite.), (Recommended Action: Please reinsert the PM back in the satellite.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEv2-6-SA_UP ### Response: (Severity: 6), (Category: SECURITY), (Description: IKEv2 SA is established.), (Recommended Action: No Action Required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-ACCESS_CHECK ### Response: (Severity: 3), (Category: MGBL), (Description: The TTY Server previously encountered an unexpected error while applying access configuration changes to a TTY. As a result it cannot allow future connection requests to be authorized.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-3-TYPE_LOOKUP ### Response: (Severity: 3), (Category: MGBL), (Description: The process that is described by the node ID and job ID in this message sent a request for a stats type ID that cannot be handled. This will result in a failure to register for statistics collection.), (Recommended Action: Restarting the process described in this message will cause the request to be resent. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_TSF_SOT_MISS_ERROR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_TSF_SOT_MISS_ERROR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MLIB_DEBUG-3-ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: This is a catch all error message. It usually means an uncorrectible problem), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDS_DB-3-CONN_CONNID ### Response: (Severity: 3), (Category: OS), (Description: Failed to get the connection id.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTS2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_PROXY-3-ERR_SYSDB_THREAD ### Response: (Severity: 3), (Category: FABRIC), (Description: The fabric proxy failed to create the sysdb thread during the initialization. The driver will be non-operational due to this error.), (Recommended Action: The Proxy will recover by restarting. Verify that the fabric proxy process will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-BAD_TOOLS_VERSION ### Response: (Severity: 7), (Category: INSTALL), (Description: The tooling version does not match the installed package. The operation will not be able to proceed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBC_PROC-6-INFO ### Response: (Severity: 6), (Category: SERVICES), (Description: The system is in normal state. This is info log.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-7-POLICY_TOO_BIG ### Response: (Severity: 7), (Category: ROUTING), (Description: The policy named is very long and/or complex, and in compiling it for execution, the policy repository exhausted resource limits. This was not detected by the usual checks at configuration verification time. Rather than crash, the policy repository is left with the previous configuration for this policy, if any.), (Recommended Action: Rollback the configuration operation to regain consistency between the running configuration and the policy respoitory. Then, rewrite the policy in question in a simpler form. It may help to make use of policies with parameters to reduce the total policy size. Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RUNTIME-5-SVC_NOTICE ### Response: (Severity: 5), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CBC-2-CANBUS_BOTH_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: CBC detected both CANBUS A and CANBUS B have failed. This may be a serious hardware failure.), (Recommended Action: Reboot the LC. If the problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD_NETIO_DLL-3-UPDATE_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Null Driver partner encountered a error and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-3-SHMWIN_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: A fatal error was encountered during initialization.), (Recommended Action: If the process does not restart automatically then try manually restarting it. A likely cause for this error is that the system has run out of memory. If this is not an out-of-memory problem and restarting the process does not solve it then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LOW_VOLTAGE_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ voltage less than or equal to the low voltage alarm threshold. The QSFP+ is the pluggable optics on the line cards. The voltage threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check the 'show environment voltages'. If the system voltage is normal then replace the optics with working one (if any). If the system voltage is not normal, then make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR_DLL-3-UNCORR_INT_MCH_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An uncorrectable has occurred in the MCH (Memory Controller Hub) of the Linecard's CPU complex. The message will display the name, description, and error log. The linecard will reload after a certain threshold of number of occurances have been reached.), (Recommended Action: Contact support with the required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_SERDES-3-OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in Serdes layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code and a string interpretation of the error code. The failure indicates the Serdes device configuration failed.), (Recommended Action: Please attempt to correct the error by reloading the card by issuing the command in admin mode -reload location <> If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-BAG ### Response: (Severity: 3), (Category: OS), (Description: An internal bag function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HW_MODULE_PATCHCORD-6-PC_DELETE ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Logical Patchcord has been successfully deleted. This log message is needed to trigger EPNM reactive inventory about logical patchcord deletion.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_LINK_ATTACHED ### Response: (Severity: 4), (Category: L2), (Description: This process believes that there are no aggregatable links, but this link is marked as attached. This error is most likely caused by failing to attach or detach a link correctly.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-ASYNC_GET_CLIENT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: Unable to process the cilent start header over the control ethernet. This could lead to failure in sending the data over the control ethernet to a remote node.), (Recommended Action: If message appears only once, then no action is required. Packets will be retransmitted and system should recover automatically. If message appears continuously, then it could indicate a problem with the control-ethernet. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COREHELPER-3-CORE_WATCH_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Add of CORE_DUMP_LOCATION directory to monitored directory list failed with specified error.), (Recommended Action: Check dumper process, show context, collect console message. Report this message to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_LIB-4-INTERNALERR ### Response: (Severity: 4), (Category: INSTALL), (Description: An internal software error occurred.), (Recommended Action: An internal software error occurred while getting details about the install operation. This internal error will be recovered automatically. Please retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-PACKAGE_LOCATION_LICENSE_INVALID ### Response: (Severity: 4), (Category: LICENSE), (Description: A feature configuration was done on a location without a valid license), (Recommended Action: Puchase the package license for the location) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_RETRY_EXCEED_GSP ### Response: (Severity: 4), (Category: L2), (Description: After attempting to create the GSP group used for communications with the Bundle Manager process on another node a number of times, the retry limit has been exceeded. The cause of the failure is very likely to be some external communication failure - so check for evidence of this. The process will exit and be restarted automatically so no futher action is needed for Bundle Manager to retry.), (Recommended Action: Check that other processes are not reporting similar communication errors, as this is likely to be a general communication problem. The Bundle Manager process has exited and will be restarted, so no action is needed, though unless the communication problem is resolved the process will still not be able to startup.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_LCP-4-MISSING_AUTHENTICATION_LIST ### Response: (Severity: 4), (Category: L2), (Description: One or more PPP interfaces have been configured to authenticate the peer using the authentication list identified in the error message, but this authentication list has not been configured in AAA itself. As a result PPP will be unable to authenticate the peer and the line protocol on the relevant interface or interfaces will not come up.), (Recommended Action: Configure 'aaa authentication ppp ...') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-REPROGRAM_POLICERS ### Response: (Severity: 4), (Category: OS), (Description: It failed to reprogram a flow policer when it had received a request to reprogram all flow policers to HW.When this issue happens, it will trigger an automatic restart.), (Recommended Action: Check the status of Metro IPC Server because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_FADB_MAIN-3-SYSDB_LIST_FREE_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB FADB encountered an error while attempting to free a list while getting the sysdb inventory), (Recommended Action: Search the event logs for events/errors related to the failure reason. Sysdb is part of overall system. If there are failures here, then other processes may also exhibit similar problems.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-SENT_NOTIF_BADHOLDTIME ### Response: (Severity: 5), (Category: ROUTING), (Description: A BGP notification message of unacceptable hold time has been sent.), (Recommended Action: This message is info only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SUBS_AIPC_UTIL-2-INIT_FAILURE ### Response: (Severity: 2), (Category: SUBSCRIBER), (Description: Printd when Subscriber aipc util or its clients fail to initialize necessary data structures and memories. If the error originates from the system call the error message is also printed. The process cannot proceed without this module initialization.), (Recommended Action: The sysmgr will retry to start the process. If it cannot be restarted it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-ECM_OPEN ### Response: (Severity: 3), (Category: OS), (Description: PlaceD daemaon was unable to open ecm.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-ORA_INSTBUILD ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error in the routing policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-BF_OVR_ERR_FIA11 ### Response: (Severity: 3), (Category: PLATFORM), (Description: FIA11 burst FIFO overflow error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-3-CONFIG_LOCAL_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The set of primary or secondary VLANs on a bundle interface of the iccp-group does not match the secondary or primary set of VLANs for the same bundle interface on the other member of the redundancy group.), (Recommended Action: Verify the configuration under l2vpn redundancy. Ensure that the primary and secondary set of VLANs for a specific bundle interface is the reciprocal of the primary and secondary set of VLANs on the same bundle interface on the other member of the redundancy group.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-3-SERIAL_ID_NULL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Once ROMMON 1.22 is rolled out, all multi-chassis testbeds should upgrade to it to avoid problems of more than one RP getting the same rack number assigned. This msg warns the operator that an RP was detected that had older ROMMON and should be upgraded ASAP.), (Recommended Action: Upgrade the ROMMON to ver 1.32 or more Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6-3-ADD_ENCAP ### Response: (Severity: 3), (Category: IP), (Description: Failed to add pre-switch and pre-route caps to FINT), (Recommended Action: Restarting ipv6_io may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-PORT_EXCEEDS_MAX ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The port number must not exceed UINT16_MAX.), (Recommended Action: Check the port number of the interface in XR_INTERFACES.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-4-OFFLOAD_HW_PROFILE_MISMATCH ### Response: (Severity: 4), (Category: FABRIC), (Description: 1. Mismatch found between the current offload profile and the newly configured offload profile. Needs attention with LC reload.), (Recommended Action: System LC is inconsistent. Need to reload the LC in order to activate the new mpls profile. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-RX_ALARM_LOF ### Response: (Severity: 3), (Category: PLATFORM), (Description: The BITS receiver has detected OOF defect for incoming signal. For T1 mode OOF is declared when out of every four frame bits two or more frame bits are received in error. For E1 mode OOF is declared when three consecutive incorrect FAS is received. Also for E1 mode(CRC-4 framing) OOF can be declared when 915 or more CRC blocks out of 1000 are received in error. Additionally for E1 mode(CAS signalling) OOF can be declared when two consecutive multiframe alignment words are received in error or, for a period of one multiframe, all bits in timeslot 16 are zero.), (Recommended Action: 1) Ensure framing format on port matches framing format on the line. 2) Configure to other framing format to check if error clears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_LCP-5-MTU_NEGOTIATED ### Response: (Severity: 5), (Category: L2), (Description: The PPP MTU is reduced when the PPP MRU of the peer is less than the PPP MTU derived from the locally configured interface MTU. The reduced value will be used until LCP is renegotated (such as when the interface goes down and comes back up, or a new MTU is configured), or if the PPP encapsulation is removed from the interface. The MTU then returns to the configured value and another message will indicate if a value less than the configured value is negotiated again. The reduced MTU is a normal part of PPP operation and is not indicative of any problems.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_7_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_7 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_CONF_PRX-3-ERR_DETAILS ### Response: (Severity: 3), (Category: SECURITY), (Description: Client address, error, error description.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_6_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-3-DSP_LINE_TX_LOL ### Response: (Severity: 3), (Category: PLATFORM), (Description: No line lock between the NPU and DSP), (Recommended Action: Contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-4-LSP_OOR_GREEN_TRANSITION_TIMER ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_ILMI-2-IM_MSG ### Response: (Severity: 2), (Category: L2), (Description: Error in IM(Interface Manager) operation first %s - Type of the failure second %s - Interface/PVC which failed the lookup This error happens on an LC with ATM interfaces.), (Recommended Action: Check if the interface or pvc exists and retry the operation. Collect required_info. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-3-RESET ### Response: (Severity: 3), (Category: FABRIC), (Description: The fabricq ASIC is reset due to the reason displayed in the message. Most often the situation recovers after ASIC reset. If the resets persists, contact technical support with the following information.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-OPTICS_LINE_RATE_UNSUPPORTED ### Response: (Severity: 3), (Category: L2), (Description: Optics unable to support configured line-rate; replace optics OR change configuration.), (Recommended Action: Replace optics OR change configuration) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-XAUI_0_FRAG_ERR_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: XAUI interface to NPU-0 reported fragmentation error on TX side on bridge instance - 0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-NONEIGHBOR ### Response: (Severity: 4), (Category: ROUTING), (Description: OSPF hello, database description, or database request packet was received, but the router could not identify the sender. This is a normal occurrance if a link flap occurs on the router receiving the packet.), (Recommended Action: This situation should correct itself. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-CHECKSUM_FAIL ### Response: (Severity: 3), (Category: OS), (Description: A checksum of a record is wrong. The file could be corrupted. The file should be saved to other place for later debugging, and then it should be removed to recover current situation.), (Recommended Action: The file should be saved to other place for later debugging, and then it should be removed to recover current situation. Please clear the OBFL files, as it might be because of corrupted records. CLI : admin clear logging onboard corrupted-files location If the issue is seen after clearing the files, please collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging 5. show tech-support sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-COMMENT_LIMIT ### Response: (Severity: 3), (Category: MGBL), (Description: Multiple lines of comments associated for a command is considered as a single (multiline) comment for that command and the total length of all the comments would be considered as the total length of the comment associated to that command. Any comments beyond this limit will be discarded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP-7-INTERNAL ### Response: (Severity: 7), (Category: MGBL), (Description: The HTTP Server has encountered internal error conditions or this point in the code should not have been reached. The HTTP process may need restarting if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: T1E1_LNM-5-ENABLED ### Response: (Severity: 5), (Category: L2), (Description: Link Noise Monitoring has been enabled for the warning level and T1/E1 controller specified in the message.), (Recommended Action: This is an information message to notify that Link Noise Monitoring has been enabled on the T1/E1 controller identified in the message. No user action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-EA_SCOL_INIT_FAILURE ### Response: (Severity: 3), (Category: QOS), (Description: Statsd registration failed. QoS drops will not be reported for any qos enabled interfaces in the output of show interface CLI.), (Recommended Action: Restart QoS EA process Get JID from 'show processes qos ea location <>' 'process restart JID location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-SYSDBOPERATION ### Response: (Severity: 3), (Category: MGBL), (Description: 'The sysdb find data operation failed. The error is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPP-3-ERR_GENERAL ### Response: (Severity: 3), (Category: SECURITY), (Description: Error description, error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-MARTIAN ### Response: (Severity: 4), (Category: ROUTING), (Description: The specified LSP contains a prefix advertisement to an invalid martian prefix and the prefix has been ignored. As the prefix is invalid there should be no impact to routing as no traffic should be destined to the prefix. This message is however indicative of a problem in the router which issued the LSP as it should not have advertised such a prefix.), (Recommended Action: Identify the source of the offending packet and correct it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-3-INTERRUPT_ATTACH_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Interrupt attach has failed , this may be a program level error), (Recommended Action: Please contact support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-3-EVM_CREATE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The rpl multi-version coordinator was unable to obtain the event handler. This handle is required for all base level communitions with the rest of the system, so the coordinator was shutdown so sysmanger could attempt to restart.), (Recommended Action: This error message may be transient. Restart policy_repository and try the use case again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND-3-ERR_AIB_ADJ ### Response: (Severity: 3), (Category: IP), (Description: The IPv6 Neighbor Discovery (ND) process (ipv6_nd) failed to add or delete an adjacency in the Adjacency Information Base (AIB). This is normally a transient problem arising from temporary unavailability of the AIB process (aib), and corrects itself when aib returns to normal operation. Correct operation can be confirmed by checking that there is a matching AIB entry for each ND cache entry.), (Recommended Action: Confirm that updates in ND are reflected in AIB: show ipv6 neighbor [location node-id] show adjacency ipv6 [location node-id] Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGPTE_LIB-4-ERR_MEM_ALLOC ### Response: (Severity: 4), (Category: ROUTING), (Description: The process failed to allocate memory for the specified resource. This could be because the topology is too large for the memory installed in the router.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_1_ERR1_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 1 ran into error-1 on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_0_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-CHECKPOINT_ALLOC_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Checkpointing is a mechanism to update the redundant RSP with the current configuration and status of the system to help takeover in case of a failover. The checkpoint mechanism needs to be initialized for Sync-controller to update the standby RSP with current frequency syncronization status. This failure could be because of memory allocation failure.), (Recommended Action: * REDUCE *) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-DATA_XFER_ERR ### Response: (Severity: 3), (Category: IP), (Description: A software entity is unable to transfer data to/from the internal control ethernet server. This may be caused by momentary unavailability of internal buffers to the ethernet server, which will recover by itself; or, the ethernet server is inresponsive. This is a n error message that should only occur infrequently.), (Recommended Action: If the message appears only once, then no action is required. Packets will be retransmitted and system should recover automatically. If message appears continuously, then it could indicate a problem with the control-ethernet.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-6-UPD_GEN_RECOVERY ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSLA-6-DISC_LIMIT ### Response: (Severity: 6), (Category: MGBL), (Description: Discovered PE targets has exceeded the maximum number.), (Recommended Action: Dicrease PEs in a topology or stop ipsla mpls-lsp-monitor which are not required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM_LIB-6-OTHER_LIBRARY_ERROR ### Response: (Severity: 6), (Category: OS), (Description: Error in other library), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-DLINK ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBJ_MGR-3-INIT ### Response: (Severity: 3), (Category: APP_INFRA), (Description: When 'object group' configuration is first added, the OBJ Manager (obj_mgr) process starts and initializes. Something has failed in this proceedure and may prevent OBJ Manager from functioning.), (Recommended Action: Allow OBJ Manager to restart. You can further remove and re-add 'object group' configuration. If the problem persists, contact Cisco support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-4-CLIENT_REPLY_FAILED ### Response: (Severity: 4), (Category: OS), (Description: The Linux Packet Classifier received a message from the xlncd client process, but was unable to send a response. The xlncd client process may remain blocked waiting for a response.), (Recommended Action: The Linux Packet Classifier and xlncd are required for successful operation of the Linux datapath. If Linux datapath operation is important, and problems are seen, then first try restarting xlncd. If problems persist, try restarting spp, but note that both XR and Linux traffic will be affected. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-2-BIST_FAILURE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Crossbar driver detected ASIC BIST failure.), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-6-LOST_CONNECTIVITY ### Response: (Severity: 6), (Category: PLATFORM), (Description: This node has lost connectivity via ethernet with the mentioned node id. An attempt is being made (at the time of this msg) to connect via fabric to the node.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-6-MBIST_STATUS_INFO_PASSED ### Response: (Severity: 6), (Category: FABRIC), (Description: MBIST test completed successfully. Board will reload to resume normal operations.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2VPN_FGID-3-MEM_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to allocate memory from heap.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_RETRY_EXCEED_IMP ### Response: (Severity: 4), (Category: L2), (Description: The maximum number of attempts to retry an IMP message has been exceeded. An error has occurred in the clean up of a bundle, so there may be residual data for the bundle in the linecard components which could cause subsequent problems. Restart the process that reported the error to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEV2-7-CONFIG_WRITE ### Response: (Severity: 7), (Category: OS), (Description: A MB command is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COMMON-0-LC_HEADLESS_ACT_RSP_HB_REQ_FAILURE ### Response: (Severity: 0), (Category: PLATFORM), (Description: This LC has timed out waiting for Heartbeat requests from the active RSP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PM_TEST-3-ERROR_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: vkg_pm_test encountered a fatal error and is not able to recover from the error. A reason text will be supplied call support with this text. An integer errno will also be printed.), (Recommended Action: This is just test software which the customer does not get.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-FGID_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-STANDBY_OPEN_TIMEOUT ### Response: (Severity: 7), (Category: HA), (Description: Multiple attempts to open the messasge channel to the standby node (either the application itself or the checkpoint proxy) failed due to either the proxy not running on the standby or the application itself not running on the standby. If the application should run on the standby, then it must call chkpt_init() in order for mirroring to succeed.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-PHY_CLOCK ### Response: (Severity: 4), (Category: L2), (Description: The PHY device experienced a distributed clocking failure which resulted in a link flap. A reset of the PHY device corrected the issue.), (Recommended Action: Software corrected the issue by power cycling the PHY device. If any loopbacks have been configured on the port, they may need to be re-configured.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-LOCAL_ADDRESS_FAILURE ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to allocate IP address for client.), (Recommended Action: 'Make sure ip local pool is defined and has at least one free address ('show local pool'), also make sure that the specific pool is assigned to the proper ISAKMP profile ('show crypto isakmp profile'), otherwise contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. with the exact log message received.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP Routing Policy Language (RPL) on IOS-XR? ### Response: The Routing Policy Language on IOS-XR is used to define routing policies to filter and modify BGP path attributes. It provides a rich and flexible policy definition language. RPL policies are defined separately from the BGP process and applied using the route-policy command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_SYSDB_BIND ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_16P_OC48-6-GENERIC_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The message is used to report generic info.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_ECD-6-INFO_STR ### Response: (Severity: 6), (Category: PLATFORM), (Description: PLATFORM FIB, Information), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-4-FROM_MRID_UPDATE_GLACIAL ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-TCAM_FMT_TO_HFA_MAP ### Response: (Severity: 3), (Category: OS), (Description: An tcam format to hfa mapping function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-5-DF_ELECTION_COMPLETED ### Response: (Severity: 5), (Category: L2), (Description: EVPN: Designated Forwarder election completion indicator. DF election has been calculated based on the number of nexthops present at the close of the 3 second peering window.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-IFMGR ### Response: (Severity: 3), (Category: ROUTING), (Description: The specified interface manager request failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-4-BAD_PACKET ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: NetIO received a bad packet from the driver (or from an application) that had no particle data in it. NetIO drops these packets. If too many such packets belonging to a routing protocol are received and dropped, we have a potential possibility of an adjancency flap.), (Recommended Action: If no side effects are observed nothing needs to be done and NetIO would just drop these packets and continue with its normal operation. If this message is seen many number of times, it indicates some sort of issue in the driver sending packets to NetIO and the driver needs to be analysed further, in that case Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SW_OFFLOAD-4-PROTOCOL_UPDATE_FAILED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: An error was encountered while attempting to set up protocol sessions. Affected protocols may operate incorrectly or not at all.), (Recommended Action: The system has already made repeated attempts to correct the problem automatically but without success. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option dynamic feature? ### Response: The MPLS TE path-option dynamic feature allows MPLS TE tunnels to be routed dynamically by the MPLS TE software, using a path calculation algorithm that considers the tunnel's constraints and attributes. Dynamic path-options do not require an explicit path to be configured. They provide flexibility in path selection. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-4-SET_HEARTBEAT_PRIORITY ### Response: (Severity: 4), (Category: PLATFORM), (Description: Unable to set the heartbeat pulse of this node to high priority. Proceeding with default priority, however in a high CPU consumption, this node's heartbeat pulse may get lost, causing this node to get reloaded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-RSP_MIXED_MEMORY ### Response: (Severity: 3), (Category: PLATFORM), (Description: An RSP with different memory configuration is detected. This resulted in RSP mixed memory condition in the system. Running the system in this condition is not recommended.), (Recommended Action: Please correct the condition by replacing the RSP with the same memory configuration. RSP memory configuration can be view via 'show platform' CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-INVALID_NETLINK_MESSAGE ### Response: (Severity: 4), (Category: INFRA), (Description: A Netlink message was received with mismatching header and message contents. This may suggest the message was truncated.), (Recommended Action: If the problem persists, restart the process. If the problem persists through process restarts, Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XFP-2-DEV_XFP_COMPLIANCE_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A compliance error was detected during XFP initialization. A compliance error is due to unsupported optics, checksum error, EEPROM CRC error, vendor data error, or decryption error. The XFP is the pluggable optics on the line cards. XFP initialization may happen when linecard boots up, XFP OIR and line card process restart. The optics will not be enabled if an XFP compliance error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the XFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-I2C_BUS_HANG_RECOVERY_FAILED ### Response: (Severity: 3), (Category: DRIVER), (Description: The attempt to recover from the I2C bus hang condition by CCC driver has failed.), (Recommended Action: Use hw-module location reload command to recover from this.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UCP_OUNI-6-CONNECTION_DESTROYED ### Response: (Severity: 6), (Category: ROUTING), (Description: A connection was destroyed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT-3-INTF_RETURNED_ERROR ### Response: (Severity: 3), (Category: L2), (Description: Results collection for an interface has failed.), (Recommended Action: The reason for the error must be looked into.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC14 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-3-CHAN_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to create lc_fpd_upgrade (driver) channel using event_manager_create. An error occured in fpd proceses, to creae event manager which causes a channel to be created. This might involve exiting the upgrade_fpd or lc_upgrade_fpd process. Some features like 'upgrade hw-module fpd' may not work if this error is seen.), (Recommended Action: First try to restart the process ( upgrade_fpd or lc_upgrade_fpd) and check if the problem is recovered. If not switchover RP or reboot the router either manually or via Command line. If that too fails call Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PM-3-BAD_PMLIB_SERVER_CONTEXT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Platform Manager detected a software error where the received library server context does not match the expected value.), (Recommended Action: No action is required as the software has rejected the transaction request. Please collect the error message, traceback and 'show log') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTQ3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-6-CONFIG_SCRIPT_CALLBACK_EXECUTED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_9_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias less than or equal to the low laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-5-CFP_OIR ### Response: (Severity: 5), (Category: L2), (Description: The Optic Module (CFP) for the specified port has either been inserted or removed. %s - either 'inserted' or 'removed' %d - port number.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_IN_MEM_CORR_ECC_ERROR_LNK3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast input memory correctable ECC error on link 3), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_MIN_PDU_LENGTH ### Response: (Severity: 4), (Category: ROUTING), (Description: The length (PDU_LENGTH) described in the PDUTYPE header is smaller than the minimum (MINLEN) from SOURCE_IF This system received an IS-IS packet that was LENGTH bytes long, which is shorter than the required header length for a PDUTYPE packet. The packet has been ignored.), (Recommended Action: Identify the source of the offending packet and correct it. If the message recurs 'debug isis packet-errors detail' may be used to provide a dump of the problematic PDU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-3-BAD_GRP_DELETE ### Response: (Severity: 3), (Category: OS), (Description: 'This GSP group can not be deleted since some of the members still exist within the group. The remaining members are required to leave the group before it can be deleted.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-SOFT_ERROR_ALERT_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Soft error detected on Bridge FGPA instance 2.), (Recommended Action: Please reload the board in the next maintenance window. Until then affected ports will be down. 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VRRP-4-WARN_TRAFFIC_SLAVE ### Response: (Severity: 4), (Category: IP), (Description: The peer VRRP router has mismatching configuration. The group which is configured as a slave on the router on which this message is seen may be configured as a standard non-slave VRRP virtual router on the peer.), (Recommended Action: Check the VRRP configuration for this VRID on the peer device(s). Both VRRP virtual routers must be operating in the same mode: either regular or slave.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-4-PKGMGR_WARNING ### Response: (Severity: 4), (Category: INFRA), (Description: The package manager has reported a warning condition while running.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-3-lsp_verify_peer_absent ### Response: (Severity: 3), (Category: OS), (Description: Unable to verify LSP due to absense of Peer), (Recommended Action: Check peer address specified in EXEC CLI) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-4-LINK_SHUT ### Response: (Severity: 4), (Category: FABRIC), (Description: One or more errors exceeded their threshold on this link. Five or more resets of the links did not fix the issue. The link has been shut down in hardware. Link recovery attempts will resume after OIR of the card at either end of the link, ASIC reset, driver restart, or router reload.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2SNOOP-3-INIT_RETRY ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the L2SNOOP process attempts to retry one of its initialization tasks with a network layer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-NODEID_TO_ETHER_IPADDR_FAIL ### Response: (Severity: 3), (Category: IP), (Description: Unable to derive the IP address for the server from the nodeid. The CE-TFTP process will exit and respawn itself.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-SUBAGT ### Response: (Severity: 3), (Category: SNMP), (Description: Error indicating that one of the SNMP Sub-Agent could get initialized.), (Recommended Action: Check 'show snmp sub-agent' , if noticed any sub-agent not in the list. Restart sub-agent process and check the running subagent process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA_MGR-3-EXTRACT_IDPROM_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: MPA manager was not able to extract inventory info from the IDPROM data of the module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_AIS_DEMA ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDM_LIB-6-DEBUG_SHMWINID ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an info message in the RDM lib to indicate that it may have failed at some check or representing the code flow), (Recommended Action: If this message recurs, copy the system message exactly as it appears on the console or in the system log. Collect the following information and contact your Cisco technical support representative. Provide the representative with the gathered information. - show logging - show tech rdm - show tech npu) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install boot-options command in IOS XR? ### Response: The 'install boot-options' command is used to modify the boot options for the next router reload. It allows specifying the image to boot from and other boot-related parameters. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFG_RESTORE-3-CONFIG_MIGRATION_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: cXR to eXR converted config apply fail while migration.), (Recommended Action: Check cfg_restore ctrace. Check config file present in /eusbb/.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_PRE_FEC_BER_HIGH ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-7-GET_DEV_INFO_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Device info failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check the card is a Cisco approved device if it is externally accessible. Capture 'show filesystem ' together with console log.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-LOSS_TIMER_FAILED ### Response: (Severity: 4), (Category: L2), (Description: An error occurred while restarting the loss timer for the peer MEP specified in the error message. This could cause the peer MEP to incorrectly be timed out some time later.), (Recommended Action: If the error persists and peer MEPs continually flap as a result, the problem may be corrected by restarting the cfmd process on the node where the problem is being reported.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-TREEWALK_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Core dump failed because the sparse tree processing failed.), (Recommended Action: Collect the following data and raise DDTS. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between an ABR and ASBR in OSPF? ### Response: An Area Border Router (ABR) has interfaces in multiple areas including the backbone area. It runs separate copies of the OSPF algorithm for each area. An Autonomous System Border Router (ASBR) exchanges routing information with routers in other autonomous systems. It redistributes external routes into OSPF. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR-3-FGID_ERR ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric server running on context node failed to unregister itself with the FGID Controller while node is going down.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-ALLOC_VIRT_INST_RCS ### Response: (Severity: 3), (Category: OS), (Description: A memory allocation request failed to allocate a data structure required to activate the virtual service.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK_LIB-3-PTHREAD ### Response: (Severity: 3), (Category: OS), (Description: A pthread operation failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-ERR_LOCK_FATAL ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected fatal error occured when trying operate on a pthread lock.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN_EA-3-ACL_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A non-existent ACL was detected in the Platform SPAN module.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-4-SHMEM_QUEUE_MISMATCH ### Response: (Severity: 4), (Category: OS), (Description: The Packet Classifier NetIO plugin hit an error when attempting to map in the shared memory queue. This could indicate a version mismatch, e.g. during software upgrade.), (Recommended Action: The problem should be resolved if SPP is restarted, e.g. as part of software upgrade.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-RX_SECURE_CHANNEL_TERMINATED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR support service level agreements (SLAs)? ### Response: Cisco IOS XR supports SLAs through IP Service Level Agreements (IP SLAs), allowing for the measurement of network performance metrics to ensure compliance with agreed service levels. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-4-UPDATE_CHASSIS_PROM ### Response: (Severity: 4), (Category: DRIVER), (Description: Virtual Interface Mac pool start/end address has been configured in Chassis prom. This will provide the Mac addresses required in XR VM.), (Recommended Action: Use idprom_tool to upgrade the backplane IDPROM.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-ERR_ASIC_FCRAM_ASSERT ### Response: (Severity: 3), (Category: FABRIC), (Description: Ingressq encountered an assert error in the FCRAM. The driver triggers a device reset. The device should be reinitialized.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-SUSPENSION_REQUESTED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWRMON-4-OIR ### Response: (Severity: 4), (Category: PLATFORM), (Description: 'The power-module has either been pulled/inserted.'), (Recommended Action: 'Verify if the power-module has been plugged/removed.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCCLASS-3-SYSDB ### Response: (Severity: 3), (Category: MGBL), (Description: A failure occurred related to SysDB or in one of the verify/apply/notify SysDB callback functions.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEv2-3-AUTH_SIGN_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: With IKEv2 certificate authentication, sender(initiator/responder) needs to sign the AUTH DATA using the private key corresponding to the leaf certificate from the trust_point configured under ikev2 profile, this error will be printed when if RSA key pair is not configured under trustpoint or failed to sign the auth payload), (Recommended Action: Configure a valid trustpoint with rsa keypair label attached to it) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-EVENT_ERR ### Response: (Severity: 3), (Category: L2), (Description: Some error occured in event/event manager/event connection operations. The text of the message displays the failed operation with error code. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-INIT_FEAT_EA_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failed to initialize Feature EA DLL API needed for programming of hardware resources), (Recommended Action: No action is required. Process will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If restart din't fix the problem) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XBAR_ERR-3-ERR_STR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Crossbar driver encountered an Error in operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-2-MUTEX_REVIVAL_FAILED ### Response: (Severity: 2), (Category: PKT_INFRA), (Description: The packet subsystem failed to revive the packet mutex.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_OPTICAL_PWR_OVERLOAD ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_RIB ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS encountered an unexpected error whilst performing the specified RIB operation. This may be a resource starvation problem but is most likely to be an internal programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart the IS-IS process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_MGR-3-EVM_CREATE ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure has occurred during creation of a new event manager as part of initialization of SVI infrastructure. This resulted in the restart of the process.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-RETIRED_PIE_FORMAT ### Response: (Severity: 7), (Category: INSTALL), (Description: PIE file is in an obsolete format.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_INVALID_CB ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA received an invalid callback from another process. The error message describes why it is invalid. This is most likely to be a programming error, either in PPPoE or in one of the processes it interacts with.), (Recommended Action: PPPoE MA should recover by itself.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_STORM-3-SC_MODIFY_ERR_IFH ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to program storm control as it is conflicting with an existing AC), (Recommended Action: Remove storm control config on this sub-interface) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MMW-5-LOW_CONTAINER_MEM ### Response: (Severity: 5), (Category: PLATFORM), (Description: The amount of free memory (RAM) is low in the Moonshine container.), (Recommended Action: Consider raising the container memory limit using a Moonshine config file. See https://confluence-eng-sjc1.cisco.com/conf/display/ENXR/Moonshine+Config+Files) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-6-INFO ### Response: (Severity: 6), (Category: OS), (Description: --), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-4-FLASH_WP_DISABLED ### Response: (Severity: 4), (Category: DRIVER), (Description: The DIP switch setting of card is at a position that is disabling the IOFPGA bootflash write protection. This is a safety feature to prevent unintended corruption of backup images in the bootflash during FPD upgrade.), (Recommended Action: Enable back the write protection to IOFPGA bootflash.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_GTRIE-3-ERR_INFO_RT ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the ASR9K platform FIB specific code software to indicate anomolies that are not FATAL. This error is most likely caused by a temporary situation, so is unlikely to re-occur.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN_EA-3-SRC_PORT_EXCEEDED_PER_SESSION ### Response: (Severity: 3), (Category: PLATFORM), (Description: Number of source per session supported is 100.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS LDP downstream on demand feature? ### Response: The MPLS LDP downstream on demand feature is an LDP label advertisement mode in which a downstream router advertises a label to an upstream router only when it is needed to forward traffic. This is more scalable than unsolicited downstream mode. It is enabled with the mpls ldp downstream-on-demand command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-NODEID_DECODE_FAILURE ### Response: (Severity: 7), (Category: OS), (Description: An error happened for a nodeid decoding.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between a designated router (DR) and backup designated router (BDR) in OSPF? ### Response: On multi-access networks (e.g. Ethernet), OSPF elects a DR and BDR. The DR is responsible for generating LSAs for the network and flooding them to other routers. The BDR is a hot standby for the DR. All other routers are DROTHERs and form adjacencies with the DR and BDR. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HM-4-FPING_RETRY_FAILED ### Response: (Severity: 4), (Category: HA), (Description: HA Health Monitor Fabric ping failed but will retry again), (Recommended Action: No action is required because HA Health Monitor will retry Fabric ping again) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-3-HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected an SFP Tx power greater than or equal to the high Tx power warning threshold. The SFP is the pluggable optics on the line cards. The Tx power threshold values are read from the SFP.), (Recommended Action: Verify that the device is properly inserted. Replace the SFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-MSG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Error encountered while handling messages received by tacacsd.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_HT1_ERR_CMD ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an erroneous command on the HT1 HTDP interface. This means that the HT host core has received an HT Flush, Fence, or Broadcast packet. These packets are not supported and behavior is undefined after this type of packet is received. Note: CPP does not generate these commands.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IDPROM_PARSER-3-GET_FIELD_DATA_FAILED ### Response: (Severity: 3), (Category: LIB), (Description: Failed to parse field data from raw idprom data), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE-7-ERROR ### Response: (Severity: 7), (Category: OS), (Description: Required functionality failed or returned an error), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-1-RX_MTA_FRM_RPT_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Ingress MUX encountered Rx serdes lane metaframe repeat error.), (Recommended Action: This fault would result in traffic loss. Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BAG-7-INTERNAL ### Response: (Severity: 7), (Category: SYSDB), (Description: An internal error has occurred in the bag library. Some management functions may not operate correctly.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-COND_OP_FAILED ### Response: (Severity: 3), (Category: OS), (Description: 'Failure of an operation on condition variable.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-3-SYSDB_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Sysdb api call failed.), (Recommended Action: Please collect the output of the following commands: - show tech-support lpts - show tech-support sysdb - show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WAN_INARP-2-INIT ### Response: (Severity: 2), (Category: L2), (Description: During process start up an unrecoverable error occurred. The component will exit and should be restarted by the System Manager.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_ENA-3-EVENT_MGR ### Response: (Severity: 3), (Category: MGBL), (Description: An Event Manager operation carried out by the HTTP ENA filesystem handler returned unexpected results. The HTTP process may no longer be able to function correctly, and may need restarting if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_OC3_OC12-3-ERR_PLUGIN ### Response: (Severity: 3), (Category: L2), (Description: The operation on SPA object failed. The SPA driver controls all the hardware on the SPA. If the operation on SPA fails, the SPA may not be able to boot or work properly, and the traffic may be affected. %s - error message indicating location and the reason of the error), (Recommended Action: The SPA infra will automatically restart the SPA driver up to a fixed number of times if the failure happens during SPA is booting. If the failure doesn't happen with SPA booting, manually SPA reload may be needed. Execute 'show platform' to verify the SPA is in READY state, if not, try to reload the SPA with command: hw-module subslot 0/x/x reload or if the system has no response to the command above, force to reload the SPA with follwoing sequence under config mode: hw-module subslot 0/x/x shutdown commit no hw-module subslot 0/x/x shutdown commit If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-WARN_OUTR_VLAN_SES_THRESHLD_EXCD ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions for a particular Outer VLAN on the given access interface has exceeded the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KIM-3-DEFAULT_INTF_CREATION_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: A failure occurred when attempting to create a default interface (i.e. fwdintf or fwd_ew) in the TPA system for the specified vrf. Forwarding for TPA applications (including telemetry) will likely be impacted.), (Recommended Action: Restarting the kim process or unconfiguring and reconfiguring the VRF may be sufficient to recover. A switchover or router reload may be required if this condition persists. This error condition may sometimes be worked around by configuring the VRF to use the 'mgmt' default route. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD_NETIO_TOPAZ_DLL-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: FWD encountered a memory allocation failure error), (Recommended Action: No Action required Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-2-SPA_FPGA_SW_REV_MISMATCH ### Response: (Severity: 2), (Category: L2), (Description: The FPGA software revision is different with the one supported by the running software, this could be caused by software upgrade which supports the new FPGA software revision.), (Recommended Action: Upgrade the FPGA with FPD CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-3-FWC_DB_CREATE_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: The Firewall Controller has been informed of the existence of a new interface or firewall, but attempts to create an entry for it in the relevant database have failed. The most likely cause of this problem is a lack of memory. This will have left the system in an inconsistent state.), (Recommended Action: Try to add memory or free up some by removing configuration. Restart the Firewall Controller process using the 'prcoess restart' mechanism.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-3-INTERFACE_STATS_REG_FAILED ### Response: (Severity: 3), (Category: OS), (Description: Packet Classifier has not been able to register as contributor to the interface statistics of a Management Interface.), (Recommended Action: The problem should resolve automatically by process restart, which is triggered as part of the error handling flow. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRIVER_LITE-3-ERR_DRIVER_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver encountered the annunciated error during the driver initialization. The System Manager process (sysmgr) will automatically respawn the (sfe_drvr_lite) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO-7-ERR_SEND_EGRESS_PKT ### Response: (Severity: 7), (Category: PLATFORM), (Description: Cannot send packet to pdma queue %s - error description %x - QAD queue id %d - 0 ingressq; 1 egressq; 2 fabricq 0; 3 fabricq 1 %x - error code), (Recommended Action: Ignore the message if it only appears once otherwise contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBFA-4-INIT_FAILED ### Response: (Severity: 4), (Category: INFRA), (Description: The client library failed to initialize the module specified in the error message above.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERR_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the ASR9K platform FIB specific code software to indicate anomolies that are not FATAL. This error is most likely caused by a temporary situation, so is unlikely to re-occur.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace all loc ). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-4-ACCT_TIMEOUT_FAILURE ### Response: (Severity: 4), (Category: SECURITY), (Description: Failed to send an accounting record to RADIUS or TACACS+ server), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ-3-QUEUE_GROUP_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Egressq Group/Queue creation/ deletion failed.), (Recommended Action: No action is required. Clients will automatically retry to connect to Egressq. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TOPMGR-2-MALLOC_FAILURE ### Response: (Severity: 2), (Category: PLATFORM), (Description: An explanation is provided in the syslog.), (Recommended Action: A user should be able to tell what went wrong and take actions accordingly. For instance, if the system runs out of memory then more memory needs to be installed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the Install Manager subsystem in IOS XR? ### Response: The Install Manager subsystem controls the booting process on each node in an IOS XR system. It determines the proper packages that need to be loaded on each node. Install Manager provides the CLI commands for users to perform install-related operations such as fresh installation, image upgrade/downgrade, adding/activating packages, and more. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_5_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_10_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_10 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-3-TX_INSTALL_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: TxSA/TxSC programming has failed. As recovery, session would be bought down on this interface, followed by session bringup. Traffic hit expected.), (Recommended Action: contact cisco-support by sharing the tech-support macsec.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-6-ISSU_GO_ACTIVE ### Response: (Severity: 6), (Category: INSTALL), (Description: During ISSU operation node received node role change notification .Node will change to active.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you monitor EEM reliability metrics in Cisco IOS XR? ### Response: EEM reliability metrics in Cisco IOS XR can be monitored using the 'show event manager metric' command. This command displays information about the EEM system, including policy execution counts, success rates, and failure reasons. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-MEMORY_RECOVERY_KILL_NON_PROCESSMGR ### Response: (Severity: 6), (Category: HA), (Description: The process with the indicated name and pid has been killed in an attempt to recover system memory. Since this process is not managed by processmgr, it may not be restarted. The process can be manually restarted if desired, but may continue to consume large amounts of memory.), (Recommended Action: The system is critically short of memory. Automatic recovery will attempt to stabilize the system, but there is either a memory leak or a misconfiguration. Both require operator intervention.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-3-BAD_FPGA_IMAGE ### Response: (Severity: 3), (Category: L2), (Description: The indicated FPGA image in SPI flash does not appear to have a valid meta-data. This means that a previous FPD upgrade operation did not finish the programming operation of the image.), (Recommended Action: Run again the 'upgrade hw-module location fpd ' command to re-program the image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEA_DLL-3-TCAM_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Feature EA DLL encountered error in completing TCAM operation. This can lead to mismatch between hardware and software configuration.), (Recommended Action: The most common cause of this error is that there no more free TCAM entries available for ACL. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-NSFSTATE ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal error occurred when MRIB attempted to transition to/from Non-stop Forwarding mode.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-ERR ### Response: (Severity: 3), (Category: IP), (Description: The CE-TFTP server process exitted due to some reason.), (Recommended Action: The system will try again. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_0_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser temperature greater than or equal to the high temperature warning threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_PROXY-7-PUTENV ### Response: (Severity: 7), (Category: HA), (Description: The proxy process uses putenv() to communicate with the checkpoint library. A call to putenv() failed with the specified error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is a composite bootable file in IOS XR? ### Response: A composite bootable file (e.g., comp-hfr-mini.vm-3.6.0) is a single file that contains all the packages needed to boot a router and provide full routing functionality. It includes the base OS, routing protocols, forwarding, and management packages. Composite bootable files simplify the process of installing and booting IOS XR. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_LCAC-7-ERR_INTERNAL ### Response: (Severity: 7), (Category: ROUTING), (Description: An internal system error occured.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_2_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-DUPLICATE_MT_CAPABILITY ### Response: (Severity: 4), (Category: ROUTING), (Description: The specified LSP contains multiple items advertising the same MT capability. This is an indication that the router which owns the LSP has generated its LSP incorrectly. If the MT capability items contain conflicting overload state then the message indicates this and IOS-XR determines that the router which issued the LSP is overloaded. If the MT capability items contain conflicting attached state then the message indicates this and IOS-XR determines that the router which issued the LSP is not attached.), (Recommended Action: Identify the source of the offending packet and correct it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-5-NBR_CHANGE ### Response: (Severity: 5), (Category: ROUTING), (Description: A LDP neighbor has changed state (up/down). If neighbor has gone down, then a reason for session going down is also displayed. This message appears only if the mpls ldp log neighbor command is configured.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_VPN_MIB-3-ERR_TRACE_INIT ### Response: (Severity: 3), (Category: OS), (Description: mpls vpn mib could not initialize the tracing module), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-FORCED_POWEROFF_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Multiple attempts to force the powering off of the node have failed. No further attempts will be made, all boot request sent from this affected node will not be processed.), (Recommended Action: Some hardware issue on the card might be preventing a successful power off opeartion by the system. Please contact Cisco TAC with information about this error message for support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FLOWTRAP-4-BAD_ACTOR_MAC_DETECTED ### Response: (Severity: 4), (Category: OS), (Description: The punt flow trap sampler detected an excessive flow from a source MAC address. This could result in a denial of service to other interfaces. All traffic from this source MAC address will be dropped for a specified time period.), (Recommended Action: No action necessary. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-PARAMETER ### Response: (Severity: 3), (Category: SECURITY), (Description: An invalid argument was passed to either the tacacsd or one of its funtions.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP_POLICY-3-ORA_RUN ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error in the routing policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-7-DEBUG_INFO ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLX_FPD-3-UPGRADE_MD5SUM_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: PLX FPD EEPROM is corrupted or due to I2C issues, incorrect values are being read leading to mismatch in md5sum between the EEPROM and the stored md5sum. The output of 'show hw-module fpd' will show the affected FPD.), (Recommended Action: Try another FPD upgrade operation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INFRA_MSG-5-RUN_LOGIN ### Response: (Severity: 5), (Category: INFRA), (Description: User logged into shell by executing run command), (Recommended Action: This is informational that user accessed the linux shell of the router.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-4-EVM_TM_LEAF_NEW ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when trying to create a managed timer tree leaf for the event manager.), (Recommended Action: Restarting the process may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-OUT_OF_MEMORY ### Response: (Severity: 3), (Category: IP), (Description: pmipv6d process is running out of memory. This could be due to a memory leak. It is also possible that the process has not entirely run out of memory, but there is no single block of memory of requested size available.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show processes pmipv6d detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes pmipv6d detail output, call your Cisco technical support representative and provide the representative with the gathered information. Using the Job ID from the above command, run the following command: Copy the error message exactly as it appears on the console or in the system log. Issue the show processes memory command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes memory output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show memory summary command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show memory summary output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show ipv6 mobile pmipv6 trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show ipv6 mobile pmipv6 trace output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: T1E1-4-WARNING ### Response: (Severity: 4), (Category: L2), (Description: A warning is generated while executing the function in question. The message contains info about the location and cause of the failure and possibly anticipated actions/effects.), (Recommended Action: Verify continued correct operation of T1E1.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-WAIT_EOD_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'while waiting for EOD signal API failed.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists.' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-MAIN_THREAD_BLOCKED ### Response: (Severity: 3), (Category: DRIVER), (Description: When IOFPGA driver main thread is blocked for more than the indicated time, key functionality of the driver will be affected. To allow the driver to recover from this condition, it will restart itself as part of error handling operation.), (Recommended Action: Collect the iofpga_driver core file generated because of this restart and report the problem to Cisco TAC for support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-3-UNHANDLED_FGID_DNLD ### Response: (Severity: 3), (Category: FABRIC), (Description: --), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-SYSDB_SET_FAIL ### Response: (Severity: 4), (Category: OS), (Description: Dumper stored various config related data in sysdb and it failed to get sysdb item. This might impact the dumper.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_BURNER-3-NO_MEM ### Response: (Severity: 3), (Category: PLATFORM), (Description: No enough memory.), (Recommended Action: No action is required..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-2-ENFORCE_OOC ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature is enabled without appropriate licenses.), (Recommended Action: The customer should either purchase more licenses or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_INFRA-3-STATE_LIB_ERROR ### Response: (Severity: 3), (Category: INSTALL), (Description: An unexpected failure occurred attempting to read or update key ISSU state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CBC-3-SLOT_ID_CHANGE ### Response: (Severity: 3), (Category: PLATFORM), (Description: CBC detected unexpected slot id change. The system can no longer manage/monitor the card's environment conditions. Normally this means some HW issue on slot id pins, there are 6 pins per board to indicate a valid slot, if any of the pin has noise which get changed during card operation, we will see this alert), (Recommended Action: Reboot the LC. If the problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: d1qnetio-3-SUBBLOCK_REG_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The software forwarding support for IEEE802.1Q VLANs was unable to initialise on the specified node. Software forwarding VLAN functionality on the affected is likely not to work.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-ECMP_ERR_ADD ### Response: (Severity: 3), (Category: ROUTING), (Description: Protocol has registered for no ecmp support but is adding more than one path for a route.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-3-BP_EN_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error while trying to grab or release the lock.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-6-INSTALL_OBTAIN_VERSION_FAIL ### Response: (Severity: 6), (Category: INFRA), (Description: XLNC has tried to read the loaded kernel version and the on-disk kernel version and has been unable to obtain this information. XLNC will not restart as part of an initial resync.), (Recommended Action: Please check the kernel module is loaded and that exi_driver.ko is on the disk.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-6-SYSDB_INTERN ### Response: (Severity: 6), (Category: MGBL), (Description: TTY Server is trying to access Sysdb-mc and an error [no members in group] is returned from Sysdb-mc to all the Clients. This is a generic issue with all the admin band processes which comes up earlier than sysdb svrs will have to attempt the reconnect to sysdb with ECM retry.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the ignore-lsp-errors command in IS-IS? ### Response: The ignore-lsp-errors command allows a router to ignore LSP packets with checksum errors rather than purging them. This can be useful in networks with faulty implementations that may generate LSPs with checksum errors. However, it is generally not recommended as it can lead to routing inconsistencies. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_7_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSU-3-INVALID_DATA_IN_IDPROM ### Response: (Severity: 3), (Category: LIBRARY), (Description: The power module IDRPOM is not properly programmed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_AGG-1-FABRIC_MODE_CHANGE ### Response: (Severity: 1), (Category: FABRIC), (Description: User has configured a fabric mode change. This configuration does not take effect without router reload. If standby RP present, wait for standby to be Opertional (check by 'show platform')), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-6-INSTALL_ROLE ### Response: (Severity: 6), (Category: PLATFORM), (Description: Role installation completed.), (Recommended Action: Reload the module using 'hw-module location reload') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE6_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE6_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-3-RX_BAD_PREFIX_LEN ### Response: (Severity: 3), (Category: ROUTING), (Description: An LDP message containing a destination IP Prefix with a bad prefix length has been received from a peer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_EPRTC ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from ePRTC.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-EVENT_CONN_CREATE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed to create a connection to an essential service during initialization. This is an internal software error. It requires a restart of the isis process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_CHAR_ALIGN_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-1 char alignment error on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CMPP-4-ERR_EVM_CREATE ### Response: (Severity: 4), (Category: INFRA), (Description: CMPP failed to create its Event Manager which is a critical resource for the operation of the process. This error may be caused by low memory resources. The process will abort and be restarted in an attempt to recover.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-1-ERR_HW_INIT ### Response: (Severity: 1), (Category: FABRIC), (Description: The board initialization failed the specified operation while configuring the device. The driver will exit and attempt to come up again. On multiple such failures, the board will be shutdown permanently by the shelf manager.), (Recommended Action: Collect console logs. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-5-SR_POLICY_CANDIDATE_PATH_CHANGE ### Response: (Severity: 5), (Category: OS), (Description: An SR policy changed to use a new candidate path preference. This message appears only if the segment-routing logging policy status command is configured.), (Recommended Action: If changing from a higher to lower preference, Use the reason under the inactive candidate path to determine reason for path invalidation as a hint to triage it further.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_FAN_AF_MISMATCH ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when fantrays's in the satellite are of opposite air flow type to each other. Satellite chassis shutsdown after two minutes from the time alarm is raised.), (Recommended Action: Please use fan trays of same air flow type.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCONBKUP-7-RELOAD_REPLY_ERR ### Response: (Severity: 7), (Category: MGBL), (Description: Error encountered while replying message during ASCII System Configuration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-ENCODER_ERR ### Response: (Severity: 4), (Category: SYSDB), (Description: Error starting bag encoder.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE_ERR_2_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE_ERR_2 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INVMGR-3-FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: an external API has failed in Inventory Manager. The details are supplied with the msg.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-5-PCE_PEER_STATE_CHANGE ### Response: (Severity: 5), (Category: OS), (Description: An PCE peer has changed state. This message appears only if the segment-routing logging pce peer-status command is configured for the XTC.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBIPPIMDLL-3-ENS_NRS_FAIL ### Response: (Severity: 3), (Category: IP), (Description: An error occurred during ENS or NRS communication between the PIM and BGP processes. This can occur when the pim bgp producer or the pim mdt safi consumer - -fails to register/unregister with the ENS -fails to create NRS class), (Recommended Action: This indicates a problem with ENS or NRS. Do the following action to check for errors. Copy the error message exactly as it appears on the console or in the system log. Issue the show pim trace bgp error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show pim trace bgp error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show mlib trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show mlib trace error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show pim bgp-safi command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show pim bgp-safi output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show pim trace mdt bgp command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show pim trace mdt bgp output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ_MGR-4-ERR_IMDR_NOTIFY ### Response: (Severity: 4), (Category: FABRIC), (Description: The Fabricq Mgr received an event from the iMDR Mgr that it did not register for.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPIDB-2-OPEN ### Response: (Severity: 2), (Category: PLATFORM), (Description: A run time error occurred while initializing the lc idb on the linecard. The reason for the error is dispalyed. Please call Cisco Support with the error information), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is a info message from FPD operation.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-bandwidth underflow feature? ### Response: The MPLS TE auto-bandwidth underflow feature allows auto-bandwidth to react more quickly to drops in traffic flow by triggering an immediate bandwidth adjustment when the measured rate drops below a configured underflow threshold. It aims to free up bandwidth on the tunnel path more promptly when traffic decreases significantly. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGMP_MTRACE-3-MSG_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: Messaging error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information as given in the required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GDOI-4-SVC_WARNING ### Response: (Severity: 4), (Category: OS), (Description: A service API warning is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_TOPAZ-7-ERR_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered the specified error during the initialization sequence. This facility is deemed crucial and hence the process is automatically restarted on this failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-6-SPAN_FILE_WRITE_SUCCESSFUL ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: SPAN write to file was successful.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-RIB_LOCAL_ADDRESS_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error has occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-SERDES_ERROR_LNK4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected a serdes error on link 4.), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. Also, check for any damage to the card and its backplane connectors. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XBAR-7-ERR_LWM_EVENT_BLOCK ### Response: (Severity: 7), (Category: PLATFORM), (Description: Crossbar driver Event Manager event block error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR-3-EA_INIT ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates that an error has occurred during the 'pbr_ea' process initialization and it may prevent PBR from functioning. Particular reason is included in the message), (Recommended Action: Allow the 'pbr_ea' process to restart with the command process restart pbr_ea location . If the problem persists, contact Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-ERR_CONFIG_SERVER ### Response: (Severity: 3), (Category: SECURITY), (Description: A configuration error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_0_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-XFP_HOTSWAP ### Response: (Severity: 4), (Category: L2), (Description: The inserted XFP failed to power on correctly during initialization.), (Recommended Action: None. Software corrected the issue by power cycling the XFP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATSD-3-SHMEM_CORRUPTED ### Response: (Severity: 3), (Category: MGBL), (Description: In certain unlikely scenarios it is possible that during a process restart the shared memory region used by the stats infrastructure can become corrupted. In most cases this will automatically be recovered from, however there is a possibility that the system will not be able to recover from this - The specific instance of the message will indicate which of these cases has arisen. If the system is unable to restart all necessary processes then multiple process crashes/blockages may be observed. In either case, reported statistics may be reset or inaccurate.), (Recommended Action: In the recovery case, processes should restart automatically and the system should recover so no user intervention should be required. If we are unable to automatically recover, then either the node should be reloaded, or support contacted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DAD-3-SETUP ### Response: (Severity: 3), (Category: ROUTING), (Description: There was something illegal about the setup operations that where performed. This should be a straight coding error that will fail everytime and should be cleaned up before releasing the code.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_BACKEND ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the Backend service related to use of either SysDB or SubDB. The error message describes what operation has failed and why it failed. The most likely reason for this is low memory resources or a programming error.), (Recommended Action: Consider restarting the PPP MA process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-XR_ISO_MISSING_IN_INPUT ### Response: (Severity: 3), (Category: INFRA), (Description: XR iso should be provided in the input while carving new SDR. Invalid input.), (Recommended Action: Provide XR ISO in the input image list and try carving SDR again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_TX_FIFO_OFLOW_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI interface to NPU-1 reported tx fifo overflow on bridge instance - 1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-6-MAC_LIMIT_PW_SET ### Response: (Severity: 6), (Category: L2), (Description: Number of MAC addresses in the pseudowire has reached the configured maximum. If MAC limit action to disable MAC learning and unicast flooding has been configured on the port, then that particular action might have been taken automatically.), (Recommended Action: No particular action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDM_LIB-6-RWLOCK_TIMEOUT ### Response: (Severity: 6), (Category: PLATFORM), (Description: The RDM server timed-out waiting to acquire a write lock on the global (context) read-write lock. This could happen if the client was holding the lock for too long or has exited. The RDM server will continue to operate.), (Recommended Action: The RDM server will continue to operate despite of this condition. Check if any of the rdm client processes are exit or crashed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VS_CLIENT-3-CACHE_LOOKUP ### Response: (Severity: 3), (Category: INSTALL), (Description: Test code only - will never be seen by customers.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-SLICE_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. Slice failure: Slice failure affecting all slices and no slice is powered UP.), (Recommended Action: System is not usuable. Power failure happened during system boot. Need to reload the board for recovery. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SYSDB_ITEM_TYPE_BAD ### Response: (Severity: 7), (Category: OS), (Description: Dumper keeps various config related data in sysdb. Unexpected item type under config for dumper. This might impact the funcitoning of the dumper.), (Recommended Action: Restart dumper config and see if the issue is resolved. If not please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. follow process 6. show-tech sysdb 7.If possible please collect debug messages of dumper.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_AGG-3-PM_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB server failed PM initialization with above reson.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-HW_MODULE_PROFILE_TTL_CHASSIS_CFG_CHANGED ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. If the hw-module command is used to configure the user defined configs, there will be inconsistency between the user config and the hardware. Since the driver in LC has already started the asic initalization process before this config is received. Needs attention with reloading the chassis.), (Recommended Action: N/A If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-PCIE_TXIF_FIFO_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: CIB PCIe Tx interface FIFO single bit error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-MEMORY ### Response: (Severity: 7), (Category: INSTALL), (Description: The system is running out of memory and was not able to allocate sufficient memory to carry out the requested operation), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EDRM_SERVER-3-PROCESS_INIT ### Response: (Severity: 3), (Category: L2), (Description: The initialization of the EDRM server process failed due to the indicated reason.), (Recommended Action: None. The process initialization will be retried automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_AGG-3-ERR_INTERNAL_SW ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID Aggregator encountered the annunciated SW error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_5_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGEDM-3-FAILEDREGCOMP ### Response: (Severity: 3), (Category: MGBL), (Description: 'Compiling a regular expression failed with the reason mentioned in the message. This may lead to wrong 'show config failed' listing.'), (Recommended Action: Please contact TAC with the output of the following commands: - console logs - show version - show process nvgen_server - show nvgen trace ascii-backup reverse - show configuration history If the error recurs frequently, it may be possible to rectify it by restarting 'nvgen_server' process. But please collect the logs mentioned above, before restarting the process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-IDT_RECOV_CLK_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: IDT Recovery clock I2C Failure/Success while accessing device), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_PERSIST_THRESHOLD ### Response: (Severity: 1), (Category: PLATFORM), (Description: An ASIC error threshold was crossed.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRP_UPGRADE-3-SPAWN_RM ### Response: (Severity: 3), (Category: MGBL), (Description: Failed to spawn the 'rm' process. Unable to remove existing configuration from PRP.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_11_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_11 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL_GRE_EA-3-UPDATE_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the platform specific code software to indicate anomolies while initializing GRE Feature. This error is most likely caused by a temporary situation within the feature code. %s - indicates the reason for the failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MXPDRVR-6-NCS1K_PORT_RESET_SUCCESS ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ_MGR-7-ERR_SYSDB_EDM_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabricq Sysdb Register EDM error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ASIC-3-IMDR_ERR ### Response: (Severity: 3), (Category: L2), (Description: Plim asic driver imdr errors. Typically these errors indicate failure in system services during the imdr procedure.), (Recommended Action: Check whether process 'plaspa_server' is up and running. Check if the linecard reported any other errors and/or traffic loss was observed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-BGPLS_MEM_SHUT ### Response: (Severity: 3), (Category: ROUTING), (Description: The router or OSPF process is experiencing low memory condition. As a setup to stabilizing system, the BGP-LS feature is first being disabled so as to recover memory for OSPF and system to be able to perform basic routing operation. The feature would get re-enabled once memory condition returns to normal.), (Recommended Action: Investigate the cause of low memory condition by following the standard memory troubleshooting steps. Until the condition is restored the feature will remain disabled) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-IN_BUF_CRC_ERROR_LNK3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected excessive input buffer CRC error on link 3), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. Also, check for any damage to the card and its backplane connectors. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-4-OVERSUBSCRIPTION ### Response: (Severity: 4), (Category: PLATFORM), (Description: A warning about an over subscription of ports . The warning message describes that this particular NP is over subscribed.), (Recommended Action: The warning is not critical.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_LSD-3-ERR_IPC_SEND ### Response: (Severity: 3), (Category: ROUTING), (Description: AIPC ipc_sendv returns an unexpected error other than flow control.), (Recommended Action: AIPC return unexpected ERROR code. A chance of losing lsd information. Please collect show tech for mpls_lsd and aipc for further investigation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-INSTALL_LOAD_PHASE_STARTED ### Response: (Severity: 6), (Category: INSTALL), (Description: The load phase of an ISSU operation has started - another message will be output when the phase finishes.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-3-ASIC_ERROR_SHUTDOWN_LINK_FABRIC ### Response: (Severity: 3), (Category: PLATFORM), (Description: An ASIC error has occured and cause fabric link shutdown.), (Recommended Action: An error that causes fabric link shutdown has happened and been handled *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM_MA-3-ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-5-SR_POLICY_BFD_SESSION_STATE_CHANGE ### Response: (Severity: 5), (Category: OS), (Description: BFD session state has changed for a particular LSP.), (Recommended Action: If the session state is down, then it means that dataplane may be dropping traffic. If the session state is up, then it means that at least some data is getting through.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_LQ_OFLOW_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue overflow error on XAUI 1 LQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-6-EFD_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: An interface was shut down or brought up by a local MEP after a fault condition was detected or cleared. The action is taken because the service to which the local MEP belongs has EFD configured; this message appears because the service has EFD logging configured.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KIM-3-ADD_CONNECTED_ROUTE_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: A failure occurred when attempting to create a connected route in the TPA system for the specified vrf interface. Forwarding for TPA applications (including telemetry) will likely be impacted if they use the connected route.), (Recommended Action: Restarting the kim process or unconfiguring and reconfiguring the VRF may be sufficient to recover. A switchover or router reload may be required if this condition persists. This error condition may sometimes be worked around by configuring the VRF to use the 'mgmt' default route. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-7-TIMER_INIT_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to init timer events.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_EEEC ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from EEEC.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTF_MGBL-7-INIT_FAILED ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: The process failed to initialise and will exit.), (Recommended Action: The process will be restarted automatically. If the error happens repeatedly then contact support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-BAGS_UNREG_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_UV-3-ERR_SYSDB_CONNECT ### Response: (Severity: 3), (Category: ROUTING), (Description: The ospfv3_uv process was unable to bind to SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HBAGENT-4-SET_THREAD_NEW_PRIORITY ### Response: (Severity: 4), (Category: PLATFORM), (Description: Unable to set the heartbeat pulse of this node to high priority. Proceeding with default priority, however in a high CPU consumption, this node's heartbeat pulse may get lost, causing this node to get reloaded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_OPTICS_GLOBAL_ALARM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_OUT_MEM_UCORR_ECC_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast output memory uncorrectable ECC error on link 2), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_1_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_ECM_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: The FIA driver encountered an event connection manager error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-3-POWER_FEED_REDUNDANCY ### Response: (Severity: 3), (Category: PLATFORM), (Description: The router will have insufficient power to sustain traffic in the event of an AC power feed failure.), (Recommended Action: - Please collect the following CLI command to determine the current budget situation and to see if there are any failed power modules. admin show environment power-supply - Install additional power supply modules and in case of presence of failed power module(s), replace those unit(s) until the alarm clears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_NI_INTR_BA_STALLED_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_NI_INTR_BA_STALLED interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-SIA_EXPIRE_CLOCK_CHANGE ### Response: (Severity: 2), (Category: LICENSE), (Description: SIA Grace period will expire if clock is set back in time for more than 24 hours.), (Recommended Action: Register the device to Cisco CSSM Server and rectify SIA OOC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB_API-7-ASYNC_WAR ### Response: (Severity: 7), (Category: ROUTING), (Description: 'A recoverable error condition occurred in the MRIB API'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-6-INFO_GENERAL ### Response: (Severity: 6), (Category: OS), (Description: The PA encountered some problem in genric nature or plain information.), (Recommended Action: Restarting lpts_pa may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_PRM-3-SHMWIN_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Operation on the shared memory window encountered the error.), (Recommended Action: Please collect output of the following commands: show platform show log show process blocked location <> show shmwin summary location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AMT-3-NET_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PINGMIB-3-NOTHREADCREATE ### Response: (Severity: 3), (Category: SNMP), (Description: A software error occured when the ping mib process try to create a PING request processing thread), (Recommended Action: The process will attempt to recover from this situation by exit. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Retrying ping mib with time gap might help.If that does not work contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SDT_SHOW-7-EXTEND_FAIL ### Response: (Severity: 7), (Category: OS), (Description: The show decode helper library attempted to extend its database of decode trace string data and was unable to do so. Any trace using this string may not be printable.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAK-7-EXCEPTION_LITE ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: An software exception had occurred in the packet manager library. The client process terminated with exit code -1. The reason is that the client passed an invalid packet to packet manager library and led to the exception.), (Recommended Action: Normally the client process will restart and re-connect to packet manager. If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SI-3-SD_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: And API call to service director failed. Details of the operation are part of the error message. This may impact service bringup on the configured location.), (Recommended Action: This may prevent functioning of SI on the configured location. Try restarting si process emitting this error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-3-RLDRAM_BIST_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: Egress queueing ASIC encountered a failure when doing BIST testing on its external Redunced-Latency-DRAM (RLDRAM). Possible cause for this error condition is a faulty hardware.), (Recommended Action: No action is required. The linecard is automatically reloaded. If the error persists, replace the Modular Service Card (MSC).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-FILE_OPERATION ### Response: (Severity: 3), (Category: MGBL), (Description: config process failed to perform a file operation due to either filesystem restart/busy or an internal error.), (Recommended Action: This error could happen when config process can not perform a file operation successfully. This is mostly the case when filesystem has restarted or network connectivity is broken (if tftp file). Collect the show context output, config file being copied, show config failed output, console logs, pidin, top output and contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.. Workaround: Retry the config operation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-OPEN_PROCFS ### Response: (Severity: 3), (Category: HA), (Description: Failed to open procfs file or directory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-5-LOG_NOTICE ### Response: (Severity: 5), (Category: OS), (Description: A Notice message logged.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIER-2-PCIE_FC_ENUM_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PCIE enumeration error was detected for this Fabric Card. The error prevents this card to do traffic switching thereby making it unusable), (Recommended Action: Please correct the problem by reloading the FC board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-RP_SWITCHOVER ### Response: (Severity: 6), (Category: INFRA), (Description: An RP switchover has occurred during an install operation. The formerly active RP will be removed from the install operation, and will remain out of service until the install transaction is completed. The user is required to complete the transaction by running install commit if the software is acceptable, or by reloading the router to bring the system up with the software present before the current transaction. The ongoing transaction will continue without this node.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-NOTIFY_BNM_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The CFM packet handling module has detected that there is a new BNM link, a bandwidth change on a BNM link, or the periodic timer has expired but has failed to notify the management module. As a result, the proper handling for this event (eg generating log messages and invoking EEM scripts) will not take place.), (Recommended Action: If the error persists, the problem may be corrected by restarting the cfmd process on the node where the problem is being reported.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_UV-3-ERR_MEM_ALLOC_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The ospfv3_uv process was unable to allocate memory for the specified resource.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OT-3-LIB_INIT_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: An initialization routine from a dynamically loaded library failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_TOPAZ-4-LTRACE_INIT_FAIL ### Response: (Severity: 4), (Category: FABRIC), (Description: ltrace initialization failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-PKT_INT_ERR_AT_DDRIF_0_1 ### Response: (Severity: 1), (Category: FABRIC), (Description: Packet Integrity Error at DDR interface from Punt/Bridge-0 FPGA on FIA 0.), (Recommended Action: Verify correct version of Punt/Bridge FPGA is loaded. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-7-DBGINIT ### Response: (Severity: 7), (Category: ROUTING), (Description: The rpl multi-version coordinator was unable to setup the debug handlers. This will not affect its operational, but will prevent debug commands for the coordinator from functioning.), (Recommended Action: This error message may be transient. Restart policy_repository and try the use case again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_LSD-3-ERR_IPC_BAD_MSG ### Response: (Severity: 3), (Category: ROUTING), (Description: LSD received a message with bad size or bad version.), (Recommended Action: Please collect show tech for mpls_lsd and aipc for further investigation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STANDBY-3-ERR_REGISTER ### Response: (Severity: 3), (Category: IP), (Description: Registration for an IOSXR service failed during HSRP's operation. This may indicate a connection failure with the IOSXR service as indicated in the error message.), (Recommended Action: Restart the HSRP process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-5-AUTH_VERIFY_FAILED ### Response: (Severity: 5), (Category: ROUTING), (Description: The process encountered an error when verifying the authentication digest. This may be due to misconfiguration on the local or remote system. It is possible that no currently valid keys are available or the remote system is using an invalid authentication key.), (Recommended Action: Check the password and authentication configurations on the local system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWRMON-1-IDPROM_INVALID ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'The IDPROM may be corrupted.'), (Recommended Action: Try restarting the using CLI command in exec mode - process restart pwr_mgmt If the error exists try -insert and re-insert the PM If the error exists - Replace the power module) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-4-WARNING_CSS_CERTIFICATE_EXPIRED ### Response: (Severity: 4), (Category: SECURITY), (Description: SAM found the expired CSS certificate in table had been accepted by user.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: T3E3-4-LOOPSTATUS ### Response: (Severity: 4), (Category: L2), (Description: A configurable controller loopback status.), (Recommended Action: No action reqiured. Msg displays loop status) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MVRP-4-MAD_INIT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The MVRP IO process has failed to reinitialise with the MAD following a change in bridging configuration. Periodic retries will occur to successfully reinitialise with the MAD. Until the MAD is initialised the protocol will not run.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-PARAMETER_MISSING_OR_NULL ### Response: (Severity: 7), (Category: INSTALL), (Description: An invalid parameter has been unexpectedly passed to the Install infrastructure. This is a coding error. The current request or operation will not be completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to display rollback changes in Cisco IOS XR? ### Response: To display the changes that will be rolled back, use the 'show configuration rollback changes' command. RP/0/RSP0/CPU0:router#show configuration rollback changes <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_WDMON-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that a failure has occured in the CPA interface), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAA-3-LIB_UTIL_ERROR_NO_MEM ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to allocate memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEXRC-2-WARN_INIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: The message can be displayed whenever there is a driver initialization error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-3-EVENT ### Response: (Severity: 3), (Category: SERVICES), (Description: An error occured receiving an event from the OS. The process will restart.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_L2FIB_METRO_SHOW-3-INVALID_ARG_TYPE ### Response: (Severity: 3), (Category: PLATFORM), (Description: HFR_L2FIB_METRO_SHOW has encountered an init or a sysdb error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INST_IO-7-DEVICE_FULL ### Response: (Severity: 7), (Category: INSTALL), (Description: An attempt to open or write to a file on the specified device failed because the device had insufficient free space. The node may be in an inconsistent state due to a missing or truncated file; check for other messages from applications. Remove non-critical files, such as core files and user-created files, and reload the node to re-sync its files. If this is a management node such as an RP, consider using 'install remove' to free up space by removing inactive packages.), (Recommended Action: This indicates a low resource condition. Remove non-critical files, such as core files and user-created files, and reload the node to re-sync its files. If problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-NO_OPERATION_ID ### Response: (Severity: 4), (Category: LICENSE), (Description: The license manager encountered an error while attempting to read the license operation ID. Without a valid license operation ID the license manager will not be able to support licenses locked to the affected chassis. Check the error string to determine what has happened.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-INIT_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: An unrecoverable error occurred at system initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show processes msdp detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes msdp detail output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging process msdp error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging process msdp error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-PKT_INT_ERR_AT_DDRIF_1_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Packet Integrity Error at DDR interface from Punt/Bridge-1 FPGA on FIA), (Recommended Action: Verify correct version of Punt/Bridge FPGA is loaded. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-KERNEL_INFO_MMAP_FAILURE ### Response: (Severity: 7), (Category: OS), (Description: Space might not have been allocated for storing kernel dump information), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PA_FF_CL-7-DEBUG_INIT_EVENT ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when calling the debug_init_event() function.), (Recommended Action: Restarting lpts_pa may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-OOB_FC_1_ERROR_ALERT ### Response: (Severity: 1), (Category: FABRIC), (Description: Out Of Band flow control error detected for SPAUI-1 on FIA instance, traffic would be impacted.), (Recommended Action: Please reload the board in the next maintenance window. If this fault happens on a single FIA/slice on LC, the interfaces for this slice would be shutdown; if the fault happens on RSP/RP, the RSP/RP would be reloaded. If the fault could not be cleared after card OIR, please RMA the card. 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-SYSDB_CONFIG_TIMEOUT ### Response: (Severity: 0), (Category: PLATFORM), (Description: Unable to retrieve configuration information from sysdb. The linecard will be reloaded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-XFP_I2C_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected I2C access error on XFP port.), (Recommended Action: Ensure that the XFP plugged in is supported. If not, please replace the XFP. If the problem persists, please OIR the XFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFDIAGBASE-3-CHKSUM_ERROR ### Response: (Severity: 3), (Category: DIAG), (Description: Diagnostics detected a software error computing the checksum of a recieved packet. This is not a service impacting error.), (Recommended Action: Another software component will attempt to fix the problem or may give additional error messages. Please check Bug Navigator ( https://tools.cisco.com/bugsearch?referring_site=btk ) to search for any bugs in this area. If the error messages continue, copy all error messages exactly as they appear on the screen and gather any relevant information about the circumstances. Also collect the information from the 'show logging' and 'show tech diagnostics' commands. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB-3-FGID_ERR ### Response: (Severity: 3), (Category: FABRIC), (Description: Inbar HB running on context node failed to unregister itself with the FGID Controller while node is going down.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: sse_qosrm-3-MUTEX_DESTROY_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Failed to create the mutex.), (Recommended Action: Restart the process to recover from the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-5-TIMEOUT ### Response: (Severity: 5), (Category: OS), (Description: dumper restarted due to watchdog timeout.), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_5_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_PROTECT_INFRA_UPDATE ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to register or unregister with protect infrastructure for high priority link-down notifications on the specified interface. IS-IS will still react to regular link-down events.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-3-EVM_ATTACH_FAILED ### Response: (Severity: 3), (Category: IP), (Description: The IPv4 MA process could not register the handler for the indicated event. This can happen when the process is (re)starting. The process recovers by restarting itself. If the error message doesn't persist, it can be ignored. If the error message persists, some basic ipv4 functionality may not be available.), (Recommended Action: Collect the output of show tech-support, show processes, show ipv4 ma trace, debug event-manager attach job <> from the location the error message comes from. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_CONF_PRX-3-ERR_SYSDB_BIND ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLICE_MGR_PROXY-3-SHMWIN_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Initialization of shared memory window failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-SIA_LICENSE_PENDING_STATE ### Response: (Severity: 2), (Category: LICENSE), (Description: SIA License status couldn't be obtained.), (Recommended Action: The customer should check the connection to the backend Smart Licensing server.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VLANIFMIB-4-MIBLIB ### Response: (Severity: 4), (Category: SNMP), (Description: The VLAN Interface table relationship MIB encountered an internal error. It is likely that an SNMP query that was in progress will not have been completed.), (Recommended Action: Retry the operation that caused the message to be displayed. It may help to restart the SNMP process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_CFG-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: The npu config (npu_cfg) failed to create an event manager during the initialization. The driver will be non-operational due to this error.), (Recommended Action: The npu_cfg will recover by restarting. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_REDDRV-3-ERR_RMF_REGISTER ### Response: (Severity: 3), (Category: PLATFORM), (Description: RMF registraton got failed as reply status is not ok. Please refer the reply status for more detail.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-3-SAC0_ECTW_RD_PERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-EVM_FILE_ATTACH_FAIL ### Response: (Severity: 7), (Category: OS), (Description: Dumper uses resource manager for various resons. Unexpected failure to attach pathname to the process might cause problem in the core dumping scenario.), (Recommended Action: Collect the following data and contact support. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. follow process 6. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_WRLOCK ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_1_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Rx power less than or equal to the low Rx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Rx power threshold values are read from the QSFP+.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-BOARD_NOT_SUPPORTED_ONSLOT ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is being shutdown because it is not supported on the specified CRS platform.), (Recommended Action: Remove the unsupported board and replace it with supported hardware.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_DEBUG-7-REGISTER_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-3-COMMON_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The CIH library encountered an error related to memory or data value.), (Recommended Action: An error would be reported to the client application which should handle this condition appropriately. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_SYSDB_UNPACK ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-4-FI_TOPOLOGY ### Response: (Severity: 4), (Category: FABRIC), (Description: An inconsistency between the expected and observed topologies of the fabric was detected.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-EXIT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An unrecoverable error occurred at system initialization time.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLC-5-NSF_START ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_PERSIST_SCRUB_THRESH ### Response: (Severity: 1), (Category: PLATFORM), (Description: ASIC errors have occured and need memory scrubbing, such errors have crossed threshold.), (Recommended Action: Errors have been handled. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-6-OIR_INFO ### Response: (Severity: 6), (Category: DRIVER), (Description: Optics driver module oir detecred.Insertion/Removal of Optics.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_4_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: METRO_STATS-7-ERR_MEM ### Response: (Severity: 7), (Category: L2), (Description: An error occurred in Hardware Stats Manager during shared memory operations. This may be because the system is running low on memory. The types of errors are: 1 Cannot open/reset/close shared memory window 2 Cannot allocate/free shared memory. This will cause Stats Server to not be able to have a shadow copy of stats for all clients.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the BGP route refresh capability? ### Response: The BGP route refresh capability allows a router to dynamically request a re-advertisement of routes from a neighbor. This eliminates the need to store received routes as with soft reconfiguration. It is enabled by default if both neighbors support it. Otherwise, it can be enabled with the neighbor send-community command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EEM-0-ACTION_SYSLOG_LOG_EMERG ### Response: (Severity: 0), (Category: HA), (Description: The action_syslog call from tcl script.), (Recommended Action: Please verify command(s) mentioned in tcl script prior to error message are working fine (on router prompt). If issue is still seen then please provide command details which has resulted into this error condition to technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTR1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-SHUTDOWN_ON_BOARD_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is being brought down to IN_RESET state due to occurence of multiple critical faults/alarms on the node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_SYSDB_EDM_NOTIF_GEN ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB external data manager failed to generate a trap notification. Process would continue to run normally.), (Recommended Action: This message indicate that trap notifications of the operational states of planes and bundles would not occur. If snmp managability is not enabled, this message can be ignored. However, if this functionality is necessary then restart the process by issuing the following command at the CLI of the active RP after collecting all the output of all the specified commands. 'admin process restart fsdb_server/fsdb_aserver loc ' Restart fsdb_server if the bundle state traps are missing else if plane state traps are missing restart fsdb_aserver. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_MALLOC ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error. System is out of memory - malloc failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-INVALID_ADJ_SID ### Response: (Severity: 4), (Category: ROUTING), (Description: When adjacency SID value is configured, it should be within the SR Local Block configured on the router (default 15000-15999). The adjacency SID will not be used until this config inconsistency is resolved.), (Recommended Action: Fix the configuration such that the Adjacency SID value lies within SRLB. Ignore if this is already done and warning will repeat until this is fixed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-7-CAL_CHIP_READ_RTC ### Response: (Severity: 7), (Category: MGBL), (Description: Reading value of RTC at particular time.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_LMRIB_LABEL_RW ### Response: (Severity: 3), (Category: ROUTING), (Description: A LMRIB Label Rewrite related error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Collect: -show logging -show tech-support mpls traffic-eng -show lmrib client trace for further analysis of the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DAPS-5-UTIL_HIGH ### Response: (Severity: 5), (Category: IP), (Description: Utilization exceeded high threshold across all pools. The unallocated addresses may deplete very soon and so it would be good to add more pools or address ranges for allocation to new clients. Otherwise new allocation requests will fail. Pool utilization can be monitored using the command 'show pool ipv4/ipv6'.), (Recommended Action: Add more pools or address ranges for allocation. For details regarding related configurations, please refer 'Address Pool Service Commands' chapter in Cisco IOS XR software configuration guide.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIAAPI-4-MSG_SEND_FAILED ### Response: (Severity: 4), (Category: MEDIA), (Description: The message sent to the media server failed for the specified operation number and failed for the specified reason.), (Recommended Action: Report this message to TAC if the message showed up once but recovered Report this message to TAC together with console log, 'show media', 'show media trace' if message continues) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-4-PEER_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: Some peer error occured. This is just a warning. Please ensure that the msdp peers are configured correctly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace peer command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace peer output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_EDM-3-LIST_CREATE_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The creation of the external data manager list has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-TX_FF_OVF_ERR_FIA10 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA10 Tx burst FIFO overflow error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-3-IM_INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: A software error occurred when the ANCP process tried to perform initialization with the interface manager process. The error could be because Interface Manager is unavailable at the time of ANCP initialization or a software error in either of ANCP or Interface Manager processes.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and if ANCP process is able to initialize and come up successfully after restart, then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-CONFLICTING_LSAID ### Response: (Severity: 4), (Category: ROUTING), (Description: An LSA could not be generated because there is a supernet lsa with the host bit set LSA ID that conflicts with the major net LSA ID that also needs to have host bit set.), (Recommended Action: This is a limitation in OSPF's ability to handle conflicting LSA IDs. Attempt to avoid this limitation by modifying the generation of summary LSA's so that the LSA ID's do not conflict. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-QDR_DATABIT_STUCK_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: QDR memory databit stuck on bridge instance-1.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-LBUS_READ_TIMEOUT ### Response: (Severity: 1), (Category: PLATFORM), (Description: Local Bus read operation timeout error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-2-SR_TE_LL_INVAL_NEXTOBJ ### Response: (Severity: 2), (Category: ROUTING), (Description: lspnh ll programmed to drop because of invalid next obj), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-2-OOR_TBL ### Response: (Severity: 2), (Category: ROUTING), (Description: The FIB process on the node has detected an out of resource condition for the indicated resource. Normal operation cannot resume until routes/tables are deleted and customer does a recreate of the table.), (Recommended Action: Run the following command and check which resource(s) are running low on memory: show cef resource location Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Significant routes/tables will have to be deleted followed by a reconfiguration of the table.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FLOWTRAP-4-BAD_ACTOR_MAC_DELETED ### Response: (Severity: 4), (Category: OS), (Description: A source MAC address that was previously flagged by the punt flow trap has been removed from the 'penalty box' because the interface on which it was flagged has been deleted.), (Recommended Action: No action necessary. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCT_MA-3-CFG_UNDEFINED ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: The prepaid configuration name that was specified in the prepaid command has not been defined in the system.), (Recommended Action: Define a prepaid configuration with the name used in the prepaid command or change the name in the command to an existing prepaid configuration. If the prepaid configuration is defined, then its an internal error. If issue persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-LRD_CALL_STILL_TRYING ### Response: (Severity: 4), (Category: INSTALL), (Description: The install manager needs to call some APIs to retrieve information during its initialization. If the information is not retrieved successfully install director will retry after a small time interval until success.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-EVENT_BLOCK ### Response: (Severity: 3), (Category: MGBL), (Description: The call to event_block() failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_VETHER_DRIVER-3-REPORT_BER_SET ### Response: (Severity: 3), (Category: PLATFORM), (Description: The BIP error count has crossed the threshold count w.r.t the configured threshold value.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTU1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_FADB_MAIN-3-GET_NODE_ID_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB FADB encountered an error while attempting to get node id in process fsdb_fadb), (Recommended Action: Search the event logs for events/errors related to the failure reason. Node ID management is part of overall system. If there are failures here then other processes may also exhibit similar problems. Collect all the event logs (show logging) and the output of the following command. 'admin show process fsdb_fadb location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-5-DEVICE_REPAIRED ### Response: (Severity: 5), (Category: MEDIA), (Description: The media storage card specified has some inconsitencies in the filesystem and was repaired. See log file for specific reason.), (Recommended Action: Run install verify and cfs check.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_OAM-2-SYSDB_ERR ### Response: (Severity: 2), (Category: L2), (Description: Error in sysdb operation. %s - Type of the error. This error happens on the LC with ATM interfaces It could be one of the following types: - Unknown parameter - Sysdb Tuple is not of proper type - Sysdb Tuple fetched is corrupt - Parameter was out of range - Invalid Configuration), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Error in the config that is being committed. Check the configuartion and change it according to the error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_1_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_1 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QAD_QUEUE_MODEL-3-ERROR ### Response: (Severity: 3), (Category: OS), (Description: The specified operation failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LINK-4-BERTNOTRUNNING ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Trying to stop BERT when not running), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-2-SONET_XCVR_CODE ### Response: (Severity: 2), (Category: L2), (Description: The xcvr code is displayed for both supported and unsupported sfp/xfp types for the following actions - OIR of SFP/XFP - Soft and Hard OIR of SPA/LC - unshut of SPA - Enabling power for LC), (Recommended Action: No actions are required as this is just an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTAGENT-6-INFO ### Response: (Severity: 6), (Category: INSTALL), (Description: This may not be a failure, but the information about the progress of the install operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_PFILTER_EA-3-ERR_IM_CAPS ### Response: (Severity: 3), (Category: L2), (Description: 1) An ACL could not be applied to hardware because of one of the following reasons: a) TCAM max limit has been reached. b) RLB resources are not available. c) IPv6 address compression table is full. This error can happen when a new bundle member is added and the ACL can not be programmed successfully. 2) An ACL could not be removed from hardware.), (Recommended Action: 1) When this error occurs the running-config will not be in sync with line card configuration. It is recommended that the bundle member on which the error occured be removed from the bundle. The ACL configuration may also be reduced until it can be successfully programmed on the new bundle member. 2) If the ACL could not be removed from hardware a line card reload is recommended.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: PLATFORM), (Description: Interrupt controller encountered a fatal memory allocation error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_ENA-3-SYSDB_CONN ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP Server was unable to create a connection to the SysDB component. It may be that the communication infrastructure is faulty, or that the SysDB component has not yet restarted. If the errors persist, the router may need to be restarted.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-INV_READ_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: Indicates that the switch's static configuration data could not be read or parsed successfully.'), (Recommended Action: Determine the board type (version/revision) to make sure that its of supported HW. Not all board types are supported by the inventory manager. If this is a supported type, then root cause has to be determined.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_SWITCH-6-LINK_SHUT_DOWN ### Response: (Severity: 6), (Category: PLATFORM), (Description: The intra-rack switch port was administratively shut down.), (Recommended Action: This port is being administratively shutdown. No further action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-6-XFP_OIR ### Response: (Severity: 6), (Category: PLATFORM), (Description: The Optic Interface Module (XFP) for the specified port has either been inserted or removed.), (Recommended Action: This is an info message saying the XFP is inserted/removed. Please check if there is a manual intervention to remove/insert the XFP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_DIAG-3-IFD_ETHSVR_MSG_ERR ### Response: (Severity: 3), (Category: DIAG), (Description: The diagnostic software has detected an error while running Field/Offline Diagnostic (IFD) on the target node/card under test.), (Recommended Action: Collect the console error messages exactly as it appears on the console and call cisco support engineers with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABMGR-1-PERSISTENT_SERDES_FAIL ### Response: (Severity: 1), (Category: PLATFORM), (Description: Persistent failure in serdes link.), (Recommended Action: Please try powercycling the board using command: 'hw-module loc <> reload'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-6-UNREG_PROC_SUCCESS ### Response: (Severity: 6), (Category: HA), (Description: Process un-registration for node memory state with wdsysmon is success.), (Recommended Action: No action required) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK bias less than or equal to the low laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-VSA_FORMAT_ERR3 ### Response: (Severity: 3), (Category: SECURITY), (Description: VSA format error in daemon user configuration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-SERDES_CLOCK ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. SerDes Clock Failure/Recovered. SerDes PLL Lock is lost or recovered. 2. SerDes input clock failure. This could be also result of hardware failure. Following enum defines significance of 'BMP'-SerDes LCPLL error bitmap, data. E.g. if BMP is 0x03 it means LCPLL_REFCLK0 & LCPLL_REFCLK1 is affacted. typedef enum sfe_serdes_lcpll_err_ { SDS_LCPLL_ERR_NONE = 0x0, SDS_LCPLL0_ERR = 0x01, SDS_LCPLL1_ERR = 0x02, SDS_LCPLL2_ERR = 0x04, SDS_LCPLL3_ERR = 0x08, SDS_SRD_REFCLK_Q26_ERR = 0x10, SDS_SRD_REFCLK_Q35_ERR = 0x20, SDS_LCPLL_ERR_MAX = 0xFF } sfe_serdes_lcpll_err;), (Recommended Action: PON Reset the ASIC. Collect all the event logs and the output of the following commands executed from the CLI of the active RP: 1. 'show processes sfe_driver location ' 2. Collect all traces: 'show controller sfe trace all location ' 3. dmesg and /var/log/messages from host and sysadmin VM If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_SERDES_0_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data serdes link 0 failure on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-SFPPLUS_ACCESS_PERSIST ### Response: (Severity: 3), (Category: L2), (Description: Software could not access the optics module during initialization.), (Recommended Action: Replace the SFPPLUS.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ-3-ERR_INTERNAL_ASIC ### Response: (Severity: 3), (Category: L2), (Description: Egressq ASIC reinitialization failed, this is an irrecoverable situation, and Egressq driver will be restarted.), (Recommended Action: No action is required. The process will automatically retry. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-REQ_MSG_PROCESSING ### Response: (Severity: 3), (Category: INSTALL), (Description: An error occurred during processing of a LWM message from a client.), (Recommended Action: Please check the operation requested and retry. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_FMEA-4-CLOCK_ALERT ### Response: (Severity: 4), (Category: PLATFORM), (Description: One of the internal/external clock interfaces have reported an alarm as specified in the alarm description. This does not necessarily mean any fault in the hardware. Some alarms can occur transiently during clock-events like configuration changes, network events or cabling changes. The alarms should cancel within few minutes in such cases. If the alarms persist then it may not affect routing/forwarding but timing distribution may be impacted.), (Recommended Action: Ensure cable connection between the configured interface port and external equipments is proper.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMDR-6-CHKPT_RECORDS ### Response: (Severity: 6), (Category: OS), (Description: Status information while checkpointing.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_2_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Overload bit in IS-IS? ### Response: The Overload bit is a special bit that can be set in the LSP to indicate that the router should not be used as a transit router. This is useful when the router is in a transient state, such as during startup or during a software upgrade. It prevents other routers from sending transit traffic through the overloaded router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TZ-3-TIMEZONE_CFGSTR_SET_ERR ### Response: (Severity: 3), (Category: OS), (Description: This indicate error when setting timezone string.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-NO_MEMORY ### Response: (Severity: 7), (Category: OS), (Description: Not enough memory available in the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-4-ERR_EVENT_WAIT ### Response: (Severity: 4), (Category: MGBL), (Description: The event loop has received a message of a type it does not recognize. All events should be received by handlers. This message is only a warning and does not represent a problem in its own right.), (Recommended Action: If the process is otherwise working OK then a one-off occurrance of this message can be ignored. If the process is experiencing other problems then include this error message in the details given to support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOL_DEMA ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSCMEDIA-3-TRANSPORT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: DSC Media DLL has encounered the annunciated transport error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_MFWD_FRETTA-7-ERR_BAG_REGISTRY ### Response: (Severity: 7), (Category: ROUTING), (Description: The MFWD-FRETTA library encountered internal error during sysdb/edm init setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_NI_INTR_CRC_ERR1_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_NI_INTR_CRC_ERR1 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDLPROD-6-MSG_GENERIC_ERROR ### Response: (Severity: 6), (Category: OS), (Description: BCDL producer dll encountered an error.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-7-DEBUG_SENDV ### Response: (Severity: 7), (Category: OS), (Description: debug print before msg_sendv), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-SESSION_START ### Response: (Severity: 5), (Category: L2), (Description: After all config dependencies are resolved MKA started session specific to each interface), (Recommended Action: No action required (normal operation).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-4-NLSOCK_CREATE_FAIL ### Response: (Severity: 4), (Category: DRIVER), (Description: IOFPGA driver creates Socket on Black VLAN interface (3073) for communicating with remote cards in the Chassis. If the socket creation fails, then all Ethernet communication from Niantic fails and I2C path is used to reach remote cards.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPv4-4-LTRACE ### Response: (Severity: 4), (Category: IP), (Description: There was a system call failure during initialization of the ltrace logging system. Ltrace logs may not be available.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_MEAS-4-DEPRECATED_CONFIG_BURST_INTERVAL ### Response: (Severity: 4), (Category: ROUTING), (Description: Burst-interval configuration is no longer available and will be removed in a subsequent release.), (Recommended Action: Use tx-interval to configure transmission interval for packets.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-5-INCORRECT_PARTITIONS_REPARTITION_DEVICE ### Response: (Severity: 5), (Category: PLATFORM), (Description: Some existing eUSB may have wrong FS or partitions. Check if need to reformat the eUSB. This message will get printed if there is incorrect eUSB partitions and if there a need to repartition the device.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-BGP_ENS_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-7-DEVICE_CONFIGURED ### Response: (Severity: 7), (Category: INFRA), (Description: Device is already configured. ZTP will exit.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MACE_CLIENT-0-ERR_MEMORY_MAP ### Response: (Severity: 0), (Category: PLATFORM), (Description: An error occurred in mace driver due to memory mapping failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-3-ERR_EXIT ### Response: (Severity: 3), (Category: L2), (Description: An error occurred in NPU Driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPA_1P_OC192-6-INFO ### Response: (Severity: 6), (Category: L2), (Description: OC192VPA driver general info.), (Recommended Action: show asic-error plim asic .. loc <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-BITS_CONFIG_NOT_SUPPORTED_IN_HARDWARE ### Response: (Severity: 3), (Category: PLATFORM), (Description: BITS-In and BITS-out ports support either of T1/J1/E1/2M/6M/64K modes. Framing modes and linecoding modes are specific to each BITS mode.), (Recommended Action: Ensure the following submodes are used with each BITS mode. T1/J1 - Framing mode - d4/esf T1/J1 - Linecoding mode - ami/b8zs E1 - Framing mode - fas/cas/crc4/cas-crc4 E1 - Linecoding mode - ami/hbd3 2M/6M/64K - No Framing or Linecoding modes supported Additional configurations to be considered for T1 bits-output T1 - linebuildout(FT)- 0_133/133_266/266_399/399_533/533_655 Additional configurations to be considered for E1 bits-input/output E1 - Sabyte for cas/crc4/cas-crc4 framing mode - sa4/sa5/sa6/sa7/sa8) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_LIB-3-SYSDB_ERROR ### Response: (Severity: 3), (Category: L2), (Description: A fatal error occured during sysdb_register_notification for PLIM process. With this, config change in the syslogTXfault will not be notified to the respective PLIM process.), (Recommended Action: Collect following info: - show tech-support sysdb - show sysdb registrations notification detail shared-plane-sc) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rspp_drop-3-INIT ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred when installing the capability in NetIO to process slow path packets for service diversion. If this occurred during an upgrade operation then it will cause the NetIO process to reload. Otherwise this will cause the capsulation to be unloaded,and an error will be returned to the user.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-CONFIG_MISSING_FLOW ### Response: (Severity: 3), (Category: OS), (Description: error in PIFIB flow handling configuration. The named flow type was not explicitly configured and will have default characteristics applied.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYNCFS2-7-MUTEX_UNLOCK ### Response: (Severity: 7), (Category: MEDIA), (Description: A required mutex unlock failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_ASR9K_NSR_PACKET-2-SPP_ADD_L2_HDR_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message tells is there was an error in adding the L2 header by SPP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCASTSN-3-NVSATOFFINIT ### Response: (Severity: 3), (Category: L2), (Description: An error occurred when initializing the nV Satellite multicast offload channel. Multicast offload will not function correctly. All dependent replications will happen on local device.), (Recommended Action: Please check if the igmp snooping profile has been attached to the bridge domain and if recommended nV satellite h/w, s/w is in use by using the following commands Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp snooping profile command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp snooping profile output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp snooping bridge-domain detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp snooping bridge-domain detail output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp snooping port detail debug command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp snooping port detail debug output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show nv satellite status command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show nv satellite status output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_6_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias less than or equal to the low laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-3-MESSAGE_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: A message was received and did not match any outstanding requests and also is not a standalone message. This is not a critical failure, the process can continue functioning as expected despite the message arrival, message is discarded.), (Recommended Action: If this appears once or infrequently, it is not necessary to contact TAC. If it appears continuously or comes and goes repeatedly, it is best to please collect the following details and contact TAC. Provide the following CLI output: (admin)# show canb server-stats loc all (admin)# show canb trace loc (admin)# debug canb server error loc Let the debug run 2 minutes (admin)# undebug canb server error loc (admin)# show canb trace loc (admin)# show canb server-stats loc all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_3_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser bias greater than or equal to the high laser bias warning threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlma-6-NO_MEM ### Response: (Severity: 6), (Category: L2), (Description: The VLAN MA process was not able to allocate the memory that it needed to complete the operation. VLAN functionality on the affected node may be reduced until the problem is resolved.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-FALLBACK_PSK_PEER_NOT_FOUND ### Response: (Severity: 5), (Category: L2), (Description: Connectivty Association(CA) runnning with fallback PSK, has not received a MKPDU from it's MACsec peer for at least 6 seconds.), (Recommended Action: Check connection to peer and if peer is still up and responding, make sure not to have any config conflicts(key, key-string, lifetime) across the MACsec peers, configure valid primary & fallback PSK's in the keychain repository.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-INSTALL_OPERATION_STARTED ### Response: (Severity: 6), (Category: INSTALL), (Description: An install operation has been started - another message will be displayed when it is finished.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STREE-4-START_FAIL ### Response: (Severity: 4), (Category: L2), (Description: Spanning tree could not be started on the control ethernet for the node. stp_process error messages are indicative of health of control-ethernet which is critical for system operation. Misbehavior of stp_process can cause instability in the system.), (Recommended Action: Sysmgr process will restart the stp_process if it encounters this error. Check if the 'stp_process' is up and running if this error is encountered. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-4-GEN_RC_WARNING ### Response: (Severity: 4), (Category: L2), (Description: Request ONEP failed. It may caused by ONEP configuration lost or ONEP process failed.), (Recommended Action: Check ONEP configuration and process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-5-NSR_PM_ROLE_CHG ### Response: (Severity: 5), (Category: ROUTING), (Description: ISIS is notified by PM on HA or ISSU roles.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-NPU_1_FC_OOS_3 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress flow control out-of-sync on NPU-1 interface on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-CANT_CD ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the infrastructure is behaving incorrectly. The Package infrastructure could not change to a required directory, so processing of the current operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-PROTOCOL_GENERIC ### Response: (Severity: 4), (Category: L2), (Description: The entire PDU, or one or more IEs in the PDU, were ignored due to the given error. This indicates that the last PDU sent by the peer device was not formatted correctly.), (Recommended Action: Check that E-LMI is configured on the peer device and that the link to the peer device is functionining correctly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_SERVER-3-UPGRADE_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: Update FPD upgrade ERROR), (Recommended Action: Customer immediately knows the reason of failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_CHOPPER-3-EVET_MGR_ERR ### Response: (Severity: 3), (Category: L2), (Description: This message indicates that SPA process was unable to create event manager. The process will automatically respawn up to a fixed number of times to try and recover.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-ABORTING_FORCE_RELOAD_NODE ### Response: (Severity: 4), (Category: INSTALL), (Description: Reload the node while aborting LOAD phase of install issu operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-SRLG_ANNOUNCE_ON_TERM_INTF_FAILED ### Response: (Severity: 5), (Category: ROUTING), (Description: This is to notify that SRLG announcement for term intf has failed for a tunnel.), (Recommended Action: None. This is a solicited message and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_CHAR_ALIGN_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-1 char alignment error on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_BCM8705-3-ERROR_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Ether-Ctrl process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process ether-ctrl location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_AHS_LOS_LANE0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_EVM_CONN_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKI-6-ERR_2SD_PARAM ### Response: (Severity: 6), (Category: SECURITY), (Description: CEPKI general error message with three parameters.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REBOOT_LIB-4-NODE_NOT_PRESENT ### Response: (Severity: 4), (Category: INFRA), (Description: Node to be reloaded is not present in the inventory.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-EDM_INITFAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization EDM of the CGN process on a particular node. The errors were seen during event connection operation. The process will be restarted.), (Recommended Action: Try restarting the CGN process showing this error. Please contact support if the issue does not get resolved after process restart.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TIMER-3-TWMUTEXLOCKERROR ### Response: (Severity: 3), (Category: OS), (Description: A software error occurred acquiring a mutex.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-3-APPL_DEV_RESYNC_MISMATCH ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform Fault Manager Node detected a db inconsistency when performing a resync with an application.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-6-ADMIN_CLEAR_BINDINGS ### Response: (Severity: 6), (Category: IP), (Description: The administrator cleared the bindings.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_AHS_LOS_LANE3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLARP_LITE-3-ERR_SHMEM_OPEN_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Attempt to open the shared memory fails), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_BAD_PDU_LENGTH ### Response: (Severity: 4), (Category: ROUTING), (Description: The length (PDU_LENGTH) reported in the PDUTYPE header is greater than packet length (PKTLEN) from SOURCE_IF This system received an IS-IS packet that was LENGTH bytes long, which is shorter than the required header length for a PDUTYPE packet. The packet has been ignored.), (Recommended Action: Identify the source of the offending packet and correct it. If the message recurs 'debug isis packet-errors detail' may be used to provide a dump of the problematic PDU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-0-EMERG ### Response: (Severity: 0), (Category: PKT_INFRA), (Description: An emergency error has been detected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FLOWTRAP-4-BAD_ACTOR_MAC_CLEARED ### Response: (Severity: 4), (Category: OS), (Description: A source MAC address that was previously flagged by the punt flow trap has been removed from the 'penalty box.'), (Recommended Action: No action necessary. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-6-FIRMWARE_UPGRADE_PWR_OK ### Response: (Severity: 6), (Category: PLATFORM), (Description: 'Firmware upgrade proceeding'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does IOS XR provide high availability in terms of hardware redundancy? ### Response: IOS XR platforms support redundancy of critical hardware components including route processors (RP), line cards (LC), switch fabric cards (FC), power modules, and fan trays. IOS XR provides hitless failover to a redundant RP, N+1 redundancy for FCs, and online insertion and removal (OIR) of LCs, RPs, FCs, and other components. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET-3-TX_DISABLE ### Response: (Severity: 3), (Category: L2), (Description: L2VPN Mgr has signalled at the remote AC has changed state. Due to this the local interface has been enabled/disabled in the TX direction if supported, or enabled/disabled in both directions otherwise.), (Recommended Action: If the remote AC has changed state then this message is expected. If the remote AC hasn't changed state and this condition isn't expected then this may indicate a problem, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_INTF-3-DLL_OPEN_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A failure occurred opening a dependent DLL and loading its symbols. The process is unable to run.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-INSTALL_ERROR_BUT_NO_CLI_CONNECTION ### Response: (Severity: 3), (Category: INSTALL), (Description: The incremental install operation has encountered an error. And no 'nopromppt' is supplied in the activation command. The install would ask the user a question as how to proceed.), (Recommended Action: Do '(admin) install attach ', then answer the question.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPD-3-NOPACKET ### Response: (Severity: 3), (Category: IP), (Description: This error occurs when the supplied packet ptr is NULL. Most likely a resource problem within the system.), (Recommended Action: This indicates a low-memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_1_ERR1_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 1 ran into error-1 on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-DEV_QSFP_PID_NOT_SUPPORTED ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PID not supported error was detected during QSFP+ initialization. A PID not support error is reported when either the PID can not be read or not supported on the platform. The QSFP+ is the pluggable optics on the line cards. QSFP+ initialization may happen when linecard boots up, QSFP+ OIR and line card process restart. The optics will not be enabled if a PID not supported error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the QSFP+ with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-3-RX_PKT_BAD_PDU_LEN ### Response: (Severity: 3), (Category: ROUTING), (Description: A message with invalid PDU length was received from the peer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRP_MAD-3-INVALID_MRPDU_PARSE ### Response: (Severity: 3), (Category: L2), (Description: An MRPDU packet has been received which MRP could not decode. The MRP infrastructure was unable to parse the packet correctly because certain fields are missing or truncated. The specific MRPDU will be dropped and the protocol will continue to operate. The error string includes details of the position in the packet where parsing failed.), (Recommended Action: Use wireshark or another similar tool to verify the contents of the packet on the wire and ensure it is correctly formed. If the incoming MRPDUs are correctly formed, this error suggests invalid packet metadata. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-NSR_SYNC_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Error occurred during the NSR sync between active and standby OSPF processes.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show tech-support routing ospf) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-3-DB_LOCK_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An error was encountered while trying to perform an operation on a lock. The thread will continue without retrying the operation. In most cases, no further adverse behaviour should be observed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-1-BRM_BARRIER_SYNCUP_FAILED ### Response: (Severity: 1), (Category: FABRIC), (Description: There might be a fabric disconnect in the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-4-NEIGHBOR_LIMIT ### Response: (Severity: 4), (Category: L2), (Description: The limit for neighbors in the CDP cache has been reached. No more neighbors will be added to the neighbor cache until some existing entries have been removed. The number of entries is limited to defend against DoS attacks.), (Recommended Action: Check the existing CDP neighbors for bogus entries, CDP may be the victim of an attempted DoS attack. The 'clear cdp table' command can be used if CDP neighbor entries need removing.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4MC_STATIC-7-ERR_CERR_V ### Response: (Severity: 7), (Category: ROUTING), (Description: Internal error. Cannot Register with CERR_V subsystem), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_0_ERR2_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 0 ran into error-2 on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VERSMGR_LIB-7-SYSDB_GET ### Response: (Severity: 7), (Category: INSTALL), (Description: A Version Manager library was unable to retrieve some data from SysDB, so may not be able to function. Installations may not produce the expected results.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_FSDB_FADB_LTRACE-3-INTERNAL_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: The FSDB FADB ltrace lib failed to initialize the internal ltrace), (Recommended Action: Search the event logs for events/errors related to the failure reason. Ltrace usage is common to overall system. If there are failures here then other processes may also exhibit similar problems. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you configure EPC in Cisco IOS XR? ### Response: To configure EPC in Cisco IOS XR, you need to use the 'monitor capture' command followed by the capture point name and other parameters such as the interface, direction (in or out), and filter conditions. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-TSP_A_PKT_LTH_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: TSP decoder A length error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-XIF_CNTR_MEM_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected XIF counter memory multi-bit error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-3-LIST_ITEM_COUNT ### Response: (Severity: 3), (Category: SYSDB), (Description: When sysdb get multiple items operation received wrong number of items), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-2-PROXY_ECM_EXIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: The i2c server proxy process ECM failed due to the reason mentioned in the message.), (Recommended Action: None. The ECM will automatically retry the connection until it is successful.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-RESUME_INCOMPLETE_INSTALL ### Response: (Severity: 4), (Category: INSTALL), (Description: An incomplete install was encountered - we will attempt to resume the install.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-CORE_FILE_NAME_UNAVAIL ### Response: (Severity: 6), (Category: OS), (Description: The core dump file name for this crash is invalid.), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VLANIFMIB-4-GEN ### Response: (Severity: 4), (Category: SNMP), (Description: The VLAN Interface table relationship MIB encountered an internal error during initialisation. It is likely that an SNMP query that was in progress will not have been completed.), (Recommended Action: Retry the operation that caused the message to be displayed. It may help to restart the SNMP process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR support traffic engineering? ### Response: Cisco IOS XR supports traffic engineering through MPLS-TE, allowing for the optimization of network bandwidth usage by directing traffic flows across predetermined paths based on network resource availability and requirements. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-4-ODN_ON_UNSUPPORTED_ROUTE ### Response: (Severity: 4), (Category: L2), (Description: On Demand Nexthop (ODN) or Automatic Steering (AS) is only supported on a subset of EVPN Route Types, and only some SR-TE tunnel types are supported. A Segment-Routing Traffic Engineering (SR-TE or SRv6-TE) tunnel was received on an EVPN route which does not support it, and will be ignored.), (Recommended Action: Unconfigure or modify the route-policy coloring (at EVPN evi or BGP neighbour attach point) which results in coloring routes not explicitly supported.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-6-NV_FABRIC_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: An satellite fabric interface was shut down or brought up by a nV CFM MEP after a fault condition was detected or cleared. The (auto-generated) MEP details can be used to identify the nV CFM MEP in the standard CFM show commands.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-QCR_MEM1_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected QCR MEM1 Error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_1_ERR3_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 1 ran into error-3 on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-MPLS_REG_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Service-layer's registration with LSD failed.), (Recommended Action: Service layer's registration with Label Switching Database failed. If this is seen during programming the Service layer, retry registration. If this is seen during recovery from a process restart, look at Service layer traces for more information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_BAD_SOCKET_ADDR_LENGTH ### Response: (Severity: 3), (Category: ROUTING), (Description: A packet which IS-IS has received from its network socket contains a socket address with an invalid length. This is an internal software error which indicates that the packet has been corrupted after being received by the local router but before being received by IS-IS. The problematic packet has been dropped. If this is an occasional problem then IS-IS should be able to continue operating normally when the packet is resent. If the message recurs, then IS-IS may start to operate incorrectly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_GIFT-3-MBR_RETRY_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The hardware configuration for the Bundle member has reached the maximum number of retries. Hitting this error typically indicates that the member interface has either hit physical interface creation failures, or has not been cleaned up properly.), (Recommended Action: Reload the relevant LC(s) to recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_TCAM_MGR-7-INIT ### Response: (Severity: 7), (Category: L2), (Description: Initialization of SSE TCAM Mgr process has failed due to one of the following reasons: 1) Failed to initialize event manager. This would prevent process from receiving events. 2) Failed to initialize the EDM for the IPv6 Prefix Compresssion Library. 3) Failed to initialize the IPv6 Prefix Compresssion Library itself, which inits the default compression entries. 4) event_block failed. This indicates process has encountered unexpected error while waiting for events.), (Recommended Action: No action is required. Process will be restarted. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VMANCLNT-3-VMAN_ERROR ### Response: (Severity: 3), (Category: LIB), (Description: Error messages from virtualization manager client library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBUS-3-HBM_MBIST_CHANNEL_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates possible fault with the NP HBM memory. Displays the channel error associated with the MBIST operation.), (Recommended Action: The line card needs to be returned for repair.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDM_LIB-4-HW_READ_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is an error message in the RDM lib to indicate that it failed to perform a hw read of specified NPU instance due to the specified reason.), (Recommended Action: This is a fatal error and it wont be recovered automatically. LC need to be reloaded. If the problem persists after the same, call TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-6-INTF_HANDLE ### Response: (Severity: 6), (Category: IP), (Description: 'Interface lookup failed for source-interface'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMS-7-REG_SEC_DEL_FAIL ### Response: (Severity: 7), (Category: SYSDB), (Description: Sysdb is attempting to del a registration that does not exist in its secondary registration context.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO-7-ERR_SEND_EGRESS_IPSLA_PKT ### Response: (Severity: 7), (Category: PLATFORM), (Description: Internal Error), (Recommended Action: a Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTY-3-REGISTRATION ### Response: (Severity: 3), (Category: MGBL), (Description: An unexpected error occurred when the VTY Device DLL asked the TTY Server to perform a TTY management operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR* *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY_CONNECT-2-UNLOCKING ### Response: (Severity: 2), (Category: MGBL), (Description: The TTY Connection library encountered an unexpected error releasing a lock. To avoid the potential for deadlock the process is aborting.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-4-DECAP ### Response: (Severity: 4), (Category: FORWARDING), (Description: This message indicates that an error has occurred during packet decapsulation. Particular reason is included in the message.), (Recommended Action: Please contact Cisco TAC and provide this message text as well as the information specified in required_info section.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_LOCAL-3-MAX_RETRY ### Response: (Severity: 3), (Category: L2), (Description: Pseudo-Wire fault request retries reached to its maximum value. It will display function and line here as well. The message contains info about the location and cause of the failure and possibly anticipated actions/effects.), (Recommended Action: This error indicates a problem in the code and cannot be easily recovered from. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-LSD_CONN_FAIL ### Response: (Severity: 5), (Category: ROUTING), (Description: BGP's connection to the LSD has been lost and the connection will be retried.), (Recommended Action: This message may appear after a router reboot or route-processor fail-over event, or after software maintenance operations. If this message is seen only once, no further corrective action is necessary. If this message continues to appear, please call your Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_HQ_OFLOW_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue overflow error on XAUI 1 HQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_ST2 ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from ST2.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-UNEXPECTED_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the Shelf Manager or Platform Manager encountered a critical system(OS) error. It will exit right away.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-4-LCL_ATTRIB_ENTER_OOR ### Response: (Severity: 4), (Category: ROUTING), (Description: FIB has a limit on the number of local attribute indices it allocates per per table. Check if the maximum number make sense from BGP routes/config.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-IPARM_IF ### Response: (Severity: 3), (Category: ROUTING), (Description: The specified IP/ARM request failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT_SWITCH-3-LINK_FAIL_8 ### Response: (Severity: 3), (Category: PLATFORM), (Description: PUNT link has failed.), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-3-ERR_TTY_DETAILS ### Response: (Severity: 3), (Category: IP), (Description: An unexpected error occurred when TelnetD tried to retrieve the details of a VTY from a utility library), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE3_LANE_CRC_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE3_LANE_CRC_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR_API-3-ERR_ORPHAN_COUNT ### Response: (Severity: 3), (Category: PLATFORM), (Description: A partial retrievel of buffers happened for the current process that restarted due to retrieved orphan_count less than actual orphan_count.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-7-DB_READY_Q ### Response: (Severity: 7), (Category: ROUTING), (Description: An internal software error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-2-MEMORY_RESOURCE_PROFILE_UNKNOWN ### Response: (Severity: 2), (Category: PLATFORM), (Description: Attempt to retrieve configured memory resource profile from SysDB failed, resulting in activation of the default memory resource profile.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_FULL ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process failed unexpectedly to update RIB after RIB restarted.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_SSUA ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from SSUA.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL-3-SYSDB_API_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An internal error has occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_IO-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: ROUTING), (Description: Some error occurred in Alloc/Chunk related memory operations. The text of the message displays the failed operation and the related memory construct. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_MODULATOR_BIAS ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-LTRACE_INIT_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates that ShelfmgrV2 ltrace initialization has failed. Embedded string provides the details of failed function name and the error details.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-4-TIMER_INIT_FAILED ### Response: (Severity: 4), (Category: IP), (Description: The IPV6 MA process failed to initialize its timers.), (Recommended Action: Restarting ipv6_ma may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-4-UNKNOWN_CKN ### Response: (Severity: 4), (Category: L2), (Description: Received MKPDU contains CKN different from the one active on the interface), (Recommended Action: Check the peer end configuration, and confirm both ends have the same CKN, CAK pair configured) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-RX_PKT_LEN_ERR_FIA11 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet length error FIA 11 interface.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-IP_ADDR_TOO_LONG_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error has occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-DUP_RTRID ### Response: (Severity: 3), (Category: ROUTING), (Description: OSPF received hello packet from a neighbor which has the same router-id as this routing process. A full adjacency cannot be established.), (Recommended Action: OSPF router-id should be unique. Change the neighbors router-id.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2VPN_DEBUG-7-REGISTER_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2VPN component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_EVM_CONN_NOTIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the planes into which the IOS XR architecture is logically divided? ### Response: The IOS XR architecture is logically divided into a management plane, control plane, and data plane. The management plane provides CLI, XML, and SNMP based configuration and monitoring. The control plane runs routing protocols, signaling protocols, and other control functions. The data plane performs packet forwarding in hardware. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-6-GRACEFUL_SHUTDOWN ### Response: (Severity: 6), (Category: ROUTING), (Description: Informs user of graceful shutdown events. User needs to be aware of these activities.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-7-ISSU_LOAD_EXEC ### Response: (Severity: 7), (Category: MGBL), (Description: 'ISSU install notification message for LOAD EXEC Phase received'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LI_EA-3-ERR_IM_CAPS ### Response: (Severity: 3), (Category: L2), (Description: 1) Li MD could not be applied to hardware because of one of the following reasons: a) TCAM max limit has been reached. b) RLB resources are not available. This error can happen when a new bundle member is added and the MD can not be programmed successfully.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_PROXY-3-ERR ### Response: (Severity: 3), (Category: L3), (Description: An internal software error occurred that prevented Route proxy from working properly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-FABRIC_CARD_RESET_REJECTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that shelf manager can not comply with the fabric software request to reload a failed node due to the reason mentioned in the message. The fabric software is only to request such an action upon fabric card failures that it can not correct without a reload attempt. Reset requests during shelf manager initialization, or if the state of the card does not support such a request are rejected. For example, if the shelfmgr detects the card to be not present, or already IN_RESET due to failed multiple reload recovery attempts, it will reject the request. Similarly, if the node is UNPOWERED or if it is already being reloaded, the request will be rejected.), (Recommended Action: The user can issue a hw-module reload if they desire to reload the fabric card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-7-CERRNO ### Response: (Severity: 7), (Category: MGBL), (Description: The TTY Server has failed to register the TTY error codes with the error subsystem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-UIDB_THRESHOLD_WARNING_PER_NP ### Response: (Severity: 3), (Category: PLATFORM), (Description: The UIDB entry utilization for a specific NP on a specific LC has exceeded the default warning threshold (90 %)), (Recommended Action: Limit UIDB usage accordingly. This is a direct result of interface/sub-interface creation, either statically configured by user input or dynamically created by protocol action. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-4-EVENT_REGISTRATION_FAILED ### Response: (Severity: 4), (Category: OS), (Description: The PA process failed while attempting to connect to an event manager channel for the indicated subsystem.), (Recommended Action: Restarting lpts_pa may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-6-CONFIG_SCRIPT_MODIFIED ### Response: (Severity: 6), (Category: MGBL), (Description: A modification to a currently configured config script was detected, meaning that the script was either created, moved, deleted, or had its contents altered. Unless it can no longer be found, the script will be reloaded. The script will subsequently function as normal, unless the modification introduced any failures, in which case a warning will be output detailing these failures.), (Recommended Action: None, unless the modification was not expected, which must be investigated, or if the modification results in a commit blocker, which must be addressed before further commits are made.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key components of the IOS XR high availability architecture? ### Response: The key components of the IOS XR HA architecture are\n- Redundant hardware: Includes fans, power, controllers, processors, line cards\n- Process restartability: Critical processes can restart after failure\n- Checkpointing: Allows processes to save state and resynchronize after restart\n- Non-stop forwarding: Packet forwarding continues during control plane failures\n- Graceful restart: Allows routing peers to maintain state across restarts\n- ISSU: Allows software upgrades without traffic loss\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-2-POWER_FAULT ### Response: (Severity: 2), (Category: DRIVER), (Description: CCC FPGA detected fault on one of the power sequencer device. This is an indication that one of the power rails connected to this power sequencer was detected to have a fault. This will result in card going to POWERED_OFF state, but CCC driver will attempt to recover from this failure by reloadig the card. The card will be placed in POWERED_OFF state if multiple attempts to recover from this failure fails.), (Recommended Action: If multiple card reload operation cannot fix the problem, check if physical OIR can address the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-HW_MODULE_PROFILE_PFC_MODE_CHANGE ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. If moving to or from buffer-extended mode, there will be inconsistency between the user config and the hardware. Since the driver in LC has already started the asic initalization process before this config is received. Needs attention with line card reload.), (Recommended Action: System LC is inconsistent. Need to reload the line card for new values to take effect. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRP_UPGRADE-3-CONF_SYNC_FAIL ### Response: (Severity: 3), (Category: MGBL), (Description: If the source device boots from a non-default disk disk0 check rommon variable BOOT_DEV_SEQ_OPER on the destination node correct the setting if necessary and retry migration If the problem persists refer to upgrade MOP for more information.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-BACKEND_EDM ### Response: (Severity: 3), (Category: OS), (Description: An internal EDM backend function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-OBFL_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process failed to log alarms due to the reason mentioned in the message.), (Recommended Action: Collect the logs mentioned in required info Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_HQ_OFLOW_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue overflow error on XAUI 0 HQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL2-3-MSG_NULL_CONTEXT ### Response: (Severity: 3), (Category: OS), (Description: The pointer to the context passed by bcdl_rack_updown_handler was NULL. This can affect inconsistency between BCDL producers and consumers.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_SERVER-2-NODE_BRINGDOWN ### Response: (Severity: 2), (Category: L2), (Description: This is a message in the Asic Scan Server to indicate that it has triggerred a critical alarm and will result in node bringdown. The reason for the failure and the status of the scan operation is reported.), (Recommended Action: Run the board diagnostics.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_OC3_OC12-3-DRV_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: SPA driver encountered the annunciated error during the driver initialization. The System Manager process (sysmgr) will automatically respawn the (spa_oc3_oc12) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-2-SR_TE_GID_EXISTS ### Response: (Severity: 2), (Category: ROUTING), (Description: An SRTE tunnel local label object was created with an existing gid value.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-POLICY_COMMUNITY_OVERFLOW ### Response: (Severity: 4), (Category: ROUTING), (Description: Policy tried to add more communities than a BGP route can hold.), (Recommended Action: Find the affected neighbor with 'show bgp community truncated'. Modify policy on the affected neighbor to delete unnecessary communities.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IEP-3-ERR_SYSDB_BIND ### Response: (Severity: 3), (Category: IP), (Description: An error occurred while using SysDB.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-CPP0_FATAL_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: The CPP device driver handled a fatal CPP0 error and requested that the QFP-CPU Bridge device driver report the error to the Platform Fault Manager.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_SENSOR_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: The sensor in the satellite module reported a critical hi/lo sensor value against the configured threshold value.), (Recommended Action: Verify current sensor temperature values using the CLI: Copy the error message exactly as it appears on the console or in the system log. Issue the (admin)# show env command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin)# show env output, call your Cisco technical support representative and provide the representative with the gathered information. --> particularly for temp output of SAT ID. Copy the error message exactly as it appears on the console or in the system log. Issue the (admin)# show env trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin)# show env trace output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-4-NSR_GLOBAL_SYNC_LOST ### Response: (Severity: 4), (Category: ROUTING), (Description: LDP Non-stop routing synchronization lost with the standby node.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-WARM_BOOT_NOT_POSSIBLE ### Response: (Severity: 4), (Category: PLATFORM), (Description: There is some unsupported configuration in use, which is not supported by warm-boot. System shall reboot in cold mode. ASIC shall be reset and traffic forwarding would be impacted. If user did not intend warm boot, then this is just an informational message.), (Recommended Action: No further recovery is needed at this point. System shall auto-recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-OVERTEMP_AMBIENT_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: Do not insert A9K-NP300-LC on V1 Fantray system. Upgrade to V2 FT and then insert A9K-NP300-LC. For internal testing with ROMMON variable, it is allowed to boot-up. But in case of Inlet temp more than 35.0C, all A9K-NP300-LCs will be put in IN-RESET state. Software won't take any further action after this.), (Recommended Action: Upgrade to V2 Fantray immediately and do not power on A9K-NP300-LC again without upgrading Fan) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOR-4-NULL_PTR ### Response: (Severity: 4), (Category: INSTALL), (Description: Unexpected parameter value passed to function.), (Recommended Action: This is an internal software error and will be corrected automatically. Please retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-2-BGP_LU_UNSUPPORTED_IGP_PATH ### Response: (Severity: 2), (Category: ROUTING), (Description: In label create/update, bgp lu has unsupported path in IGP), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-ALREADY_DONE ### Response: (Severity: 5), (Category: ROUTING), (Description: An operation could not be performed because it had already been completed.), (Recommended Action: No further action is required as software should recover automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-5-OOR_THRESHOLD_DOWN ### Response: (Severity: 5), (Category: ROUTING), (Description: Maximum number of groups accepted, either per interface or per vrf.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-EVAL_WILL_EXPIRE_WARNING ### Response: (Severity: 3), (Category: LICENSE), (Description: The device is using the evaluation period which will expire in the specified time), (Recommended Action: Use the whatever the CLI is for ID token register CLI to register this device before the evaluation period expires.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_1_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_HFR-3-ERR_IMDR_V1_PREP_CALL_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error was encountered while calling the CCI (cpuctrl) cleanup function prior to restarting the process as part of an IMDR operation. The parenthesis contain the error code and the corresponding string description for it.), (Recommended Action: Linecard reload. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-BA_UNSPEC_FAIL_13 ### Response: (Severity: 3), (Category: IP), (Description: De-registration PBU is received for an non-existent binding.), (Recommended Action: Ignore this error message if it occurs only a few times. If the error persists, then do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_EDM-3-LIST_CREATE_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The creation of the external data manager list has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-5-MSG_REPLY_ERROR ### Response: (Severity: 5), (Category: OS), (Description: The message received by an application had a wrong reply data. The message data could be corrupted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS traffic engineering interarea tunnels feature? ### Response: The MPLS traffic engineering interarea tunnels feature allows MPLS TE tunnels to be established across IGP area boundaries. This enables TE to operate in multi-area environments. Interarea TE tunnels comprise hops in different IGP areas and are signaled as a contiguous end-to-end LSP. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-MLACP_ROID_MISMATCH ### Response: (Severity: 5), (Category: L2), (Description: The peer device has transmitted a different Redundancy Object ID for the bundle to that expected.), (Recommended Action: Ensure that the ROID of the bundle (on both local and peer device) is as expected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-HW_MODULE_PROFILE_PFC_NEED_RELOAD ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. If a traffic-class is added or removed from the config, there will be inconsistency between the user config and the hardware. Since the driver in LC has already started the asic initalization process before this config is received. Needs attention with line card reload.), (Recommended Action: System LC is inconsistent. Need to reload the line card for new values to take effect. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-4-GY_DISABLE ### Response: (Severity: 4), (Category: SECURITY), (Description: Disabling diameter gy app is not recommended.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAQFPBridgeCtrl-0-OUT_OF_SYNC ### Response: (Severity: 0), (Category: PLATFORM), (Description: SPA Bridge ASIC register access failure.), (Recommended Action: Reboot the line card. If the problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-4-REBOOT_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: During the processing of a software change notice, the command to get reboot information for this notice failed. The routine will now attempt to fall back on default disposition.), (Recommended Action: Check the install logs if all the packages are downloaded and install operations completed properly Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-3-LINUX_DATAPATH_STUCK ### Response: (Severity: 3), (Category: OS), (Description: The Linux packet classifier has been unable to notify a peer thread regarding Linux datapath updates. Due to this issue, PacketIO for Linux applications may now fail.), (Recommended Action: If Linux datapath operation is important, then a process restart of the spp process (a traffic impacting operation) is necessary to recover. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBAPI-3-SYSDB_ACCESS ### Response: (Severity: 3), (Category: SNMP), (Description: SonetMIB API had trouble registering/deregistering EDM or binding/unbinding SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-BAD_DEVICE_INDEX_ENTRY ### Response: (Severity: 7), (Category: INSTALL), (Description: 'The package index file was found to be incorrect. Instdir will attempt to' ' repair it.'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-CONTEXT_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does System Manager start and manage processes on IOS XR? ### Response: System Manager starts processes based on the configuration in their process startup files. These files specify process name, path, instances, startup conditions, criticality, and placement. Sysmgr monitors each process and restarts it according to the restart policy if it fails. It can also start processes dynamically when certain config is committed. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BANNER-3-EVENT_MGR_CREATE_FAILED ### Response: (Severity: 3), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the BGP maximum prefix feature used for? ### Response: The maximum prefix feature allows a maximum number of prefixes to be configured for a BGP session. If the number is exceeded, the session can either be torn down or a warning can be logged. This protects against misconfiguration or DoS attacks. It is configured with the neighbor maximum-prefix command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-6-MPLS_SROPT_CRIT_FAIL_LABELSTK ### Response: (Severity: 6), (Category: ROUTING), (Description: Label stack is NOT supported with SRopt feature. Please check your config. This is just for information>), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTP8 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK_LIB-3-CERR_REGISTER_DLL ### Response: (Severity: 3), (Category: OS), (Description: The call register the dll using cerr_register_dll failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COREHELPER-6-DELETE_CORE ### Response: (Severity: 6), (Category: OS), (Description: Successfully deleted the core file after copying.), (Recommended Action: This message is information only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_2 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-MALFORMED_MESSAGE ### Response: (Severity: 3), (Category: SECURITY), (Description: A quick sanity check is done on all received ISAKMP messages to verify that all component payload types are valid, and that the sum of their individual lengths equals the total length of the received message. This message failed the sanity check. This continous bad messages could imply denial of service attack), (Recommended Action: 'Contact the remote peer's administrator') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS traffic engineering interarea tunnels feature? ### Response: The MPLS traffic engineering interarea tunnels feature allows MPLS TE tunnels to be established across IGP area boundaries. This enables TE to operate in multi-area environments. Interarea TE tunnels comprise hops in different IGP areas and are signaled as a contiguous end-to-end LSP. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-TX_ALARM_TAF_SYNC_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Condition raised possibly due to incorrect internal BITS transmitter configuration.), (Recommended Action: Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLC-5-NSF_STOP ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-SECURE_BOOT_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: A Secure Boot validation error has been detected on the indicated card. CCC driver will try to recover from this failure by power-cycle the card.), (Recommended Action: If the problem is persitent after multiple retries, it could be hardware related problem with the CCC FPGA, CPU Complex FPGA or BIOS.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install remove command in IOS XR? ### Response: The 'install remove' command is used to delete inactive packages from the router's storage. This helps to free up disk space. Only inactive packages can be removed. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CSI_NETIO-3-MEM_ALLOC_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Fwd basecaps dll was not able to get heap memory.), (Recommended Action: This message could be seen under low memory conditions and should recover once memory becomes available. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM-3-BATTERY_LOW ### Response: (Severity: 3), (Category: MEDIA), (Description: Detect NVRAM low battery state, the data stored in NVRAM may be destroyed after power down the board with battery low state.), (Recommended Action: 'NVRAM Battery may need to be replaced') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-GET_EVM_CTX_BY_TIMER ### Response: (Severity: 7), (Category: HA), (Description: An internal error was detected when trying to find the event manager context by the given timeout timer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-IO_MNT_LOW_MEM ### Response: (Severity: 3), (Category: MEDIA), (Description: Could not get enough memory while trying to initialize nvram.), (Recommended Action: 'Router running low in memory. Reboot if possible.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_DATAFIND ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-3-ATTACH_FAILED ### Response: (Severity: 3), (Category: L2), (Description: STP was unable to initialize IO for one or more interfaces. BPDUs will not be sent or received through these interfaces. The process has restarted to attempt to clear the error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-INSTALL_ISSU_NEXT_COMMAND ### Response: (Severity: 6), (Category: INSTALL), (Description: The run phase of an ISSU operation has finished successfully. Inform the user the operation has not completed yet.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-2-MSC_140_POWER_DISABLED_STATE_POWER_DOWN ### Response: (Severity: 2), (Category: PLATFORM), (Description: Board powering down due to power disabled state), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-HFA_REGISTER ### Response: (Severity: 3), (Category: OS), (Description: An internal hfa_register function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-NOTIF_THREAD_INIT ### Response: (Severity: 3), (Category: HA), (Description: An error occured when attempting to initialize the event manager thread.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_TX_HEAP_LOOKUP ### Response: (Severity: 4), (Category: L2), (Description: An attempt to create a new database entry for a port failed. In addition to indicating that the line card is running low on system resources, this suggests that the shared-memory database is out-of-sync with the main database. Once some system resources have been released, the bundlemgr_local process should be restarted to retry the timer creation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_LOL_MAPPERE ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-SYSDB_BIND ### Response: (Severity: 7), (Category: INSTALL), (Description: The communications infrastructure may not yet be up. If this error persists, the Install infrastructure may not be able to operate), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VASI_NETIO-3-INIT_DEBUG ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of debug for the NetIO caps. If this occured during an upgrade operation then it will cause the NetIO process to reload. Otherwise this will cause the capsulation to be unloaded, and an error returned to the user.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does the Sysdb process collaborate with Install Manager in IOS XR? ### Response: The Sysdb process collaborates with Install Manager in IOS XR by allowing the instdir process to use several trees in its namespace. The command requests passed from the instcmd process and the status of command executions by instdir are all communicated via different trees in the Sysdb. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_15_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_15 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-UPGRADE_LICENSE_AUTH_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The device has not communicated with Cisco for an extended period of time and the device has not automatically renewed the entitlement authorizations. Software upgrades will be blocked once the upgrade grace period of 90 days expires. Please check show license platform summary/detail for more information.), (Recommended Action: Customer needs to obtain a new ID token from the Cisco CSSM portal CSSM virtual account and re-register the device with CSSM.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOMAIN_SYNC-3-INIT_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Error during initialization of domain_sync daemon.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEM_PLATFORMS-2-ERR_STS ### Response: (Severity: 2), (Category: L2), (Description: Error in cem operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-6-INFO_MAC_IWF_IF_SES_TRSHLD_NO_EX ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: The number of IWF PPPoE sessions from a particular MAC address on the given access interface is no longer exceeding the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEATURE_LPTS-3-FGID_DB_RETRIES_EXCEEDED ### Response: (Severity: 3), (Category: FABRIC), (Description: A software error occurred, when the PA(Port Arbitrator) attempted to allocate FGID's from the FGID aggregator.), (Recommended Action: The process lpts_pa will attempt to recover by restarting. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD_INTF_EA-4-LOST_EVENT ### Response: (Severity: 4), (Category: L2), (Description: The specified process failed to receive an event that was sent to it.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an IPv6 address on an interface in IOS XR? ### Response: To configure an IPv6 address on an interface, use the 'ipv6 address' command in interface configuration mode. RP/0/RSP0/CPU0:router(config)#interface GigabitEthernet0/0/0/1 RP/0/RSP0/CPU0:router(config-if)#ipv6 address 2001:DB8::1/64 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSLA-7-AGENT ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-SYSDB ### Response: (Severity: 3), (Category: MGBL), (Description: The TTY Server has encountered an error using the SysDB Library.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-OPTION_NOT_SUPPORTED ### Response: (Severity: 6), (Category: INFRA), (Description: The specified option is not supported, and will have no impact on the behavior of the install operation. In most cases, this is because the option was added to allow script compatibility with another version/platform of IOS-XR.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD_BASE_NETIO-5-UNSUP_MAJOR_VERSION ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: FINT DLL does not support DLL upgrade across major version changes. This will cause netio to take default action to restart for upgrade to take effect.), (Recommended Action: This message indicates that netio will take default action to restart as fwd netio dll does not support dll upgrade across major version number changes. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-ALLOCATE_NOTIFY ### Response: (Severity: 3), (Category: L2), (Description: A CPP driver failed to allocate data.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-3-INTF_INIT_FAIL ### Response: (Severity: 3), (Category: L2), (Description: The Ethernet Link OAM Daemon was unable to initialise the specified interface. This is likely caused by a memory resource allocation error. The exact error can be found in the 'show ethernet oam interface' command.), (Recommended Action: Un-configure and re-configure the interface. If that does not resolve the problem, restarting the process will cause a retry of the initialisation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT_SWITCH-3-LINK_FAIL_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Punt link failed), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-FPGA_PCI_INIT_FAIL ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSH_IPC_EM-3-NODEID_EXTRACT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: OSH IPC ethernet media failed to extract nodeid.), (Recommended Action: restart the process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFL_MGR_COMMON-3-WRITER_DATA_CORRUPTION ### Response: (Severity: 3), (Category: INFRA), (Description: OBFL failed to write the data stored in persistent storage. This might be due to data corruption by the software or a user altering the obfl storage or files therein.), (Recommended Action: Ensure that no user has altered the files or tried to meddle with the filesystem on /mnt/plog. Process restart of obfl_mgr on the problematic node, will, in most cases resolves the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-CHKPT ### Response: (Severity: 3), (Category: FORWARDING), (Description: Failed to write/delete the checkpoint entry for the specified tunnel. This may result in inconsistent state after tunl_gre_ma restarts.), (Recommended Action: Remove and reconfigure the specified tunnel.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AIB-4-LEN_MISMATCH_CLDATA ### Response: (Severity: 4), (Category: ROUTING), (Description: Interface EAs may store private information as 'client data' on interfaces in AIB. An interface EA made an invalid attempt to change the size of this data. There may be no immediate impact on traffic, but this issue should be addressed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-3-SERVER_GENERIC_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Attach server failure. %s- Failure message.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-CFS_INIT_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: 'Nvgen server could not initialize the CFS'), (Recommended Action: Collect the show logging output, console logs and error trace. Collect the show nvgen trace output. And contact tac representative with this information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: Why is a microkernel-based architecture desirable for a carrier-grade NOS? ### Response: In a microkernel OS, most functionality resides outside the kernel in separate processes with their own protected memory space. A failure in a non-kernel process does not impact the kernel or other processes. This enables fault containment and process restartability without service disruption. Only essential core services remain in the kernel, minimizing the impact of any kernel failures. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-6-SPI_VLAN_CFG_CREATE_FAIL ### Response: (Severity: 6), (Category: INFRA), (Description: Indicates that the programming of the SPI flash with the VLAN translation configuration information failed. This implies that the CCC will only control VLAN translation programming for Sysadmin. All other VLAN translation programming will be handled by ESD. In cases where ESD is not running, VLAN programming for non-sysadmin VLAN's will not be done, leading to inconsistent control plane connectivity.), (Recommended Action: Check all logs to determine root cause of failure. May be caused by incompatible CCC PON version, lack of disk space, communication error between ESD and CCC, communication error to send PON commands, etc. Upgrade of PON may be needed. A power-cycle of the board may be required to recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-INTERNAL_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_HFR_NETIO_LIB-4-FINT_IDB_NOT_FOUND ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The FINT idb is not yet created in netio. This could be a transient condition.), (Recommended Action: Please capture the following information and if traffic loss also is being observed Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. show logging show proc blocked) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_SYSDB_BAG_FREE_INDIRECTIONS ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MARVEL-6-RX_ASYNC_MSG ### Response: (Severity: 6), (Category: L2), (Description: This error is generated when an invalid asynchronous message is received.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-INPUT_SIGNAL_ERROR_ALL_SLICE ### Response: (Severity: 1), (Category: FABRIC), (Description: Error found on trace between all instances of FIA ASIC and FPGA.), (Recommended Action: Please reload the board in the next maintenance window. If the fault could not be cleared after card OIR, please RMA the card. 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR-7-ERR_FSM_STATE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an unexpected/invalid state while trying to process an event for a client request. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_ACCESS_ALARM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-SET ### Response: (Severity: 4), (Category: MGBL), (Description: An error occurred invoking an MDA function. This could be because the object does not exist or has the wrong type. The details are in the error string.), (Recommended Action: Check that the object to set exists and has the same type as it is being set to. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-6-RETRYDB_OK ### Response: (Severity: 6), (Category: ROUTING), (Description: The FIB process had previously detected that there were one or more unresolved prefixes in the Retry database. Those have been resolved now FIB has resumed normal operation.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_POLICY-3-ORA_INSTBUILD ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error in policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-MISSING_HANDOFF_INDICATOR_OPTION ### Response: (Severity: 3), (Category: IP), (Description: Handoff Indicator option is missing in the PBU.), (Recommended Action: If the issue is seen repeatedly, do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE1_LANE_CRC_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE1_LANE_CRC_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_ERRORS-3-ERR_ECM_CREATE ### Response: (Severity: 3), (Category: L2), (Description: The ASIC Error library encountered an error during the creation of the Error Connection Manager.), (Recommended Action: An error would be reported to the client application which should handle this condition appropriately. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-2-PN ### Response: (Severity: 2), (Category: L2), (Description: The Product Number information is displayed for both supported and unsupported sfp/xfp types for the following actions - OIR of SFP/XFP - Soft and Hard OIR of SPA/LC - unshut of SPA), (Recommended Action: No actions are required as this is just an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AIB-4-DLLINFO_DB_INIT_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: AIB maintains a database for interface-type-specific DLL information but was unable to initialize it. The process will attempt to recovery by restarting. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: If the explanatory detail indicates memory exhaustion, Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PDMA_SPP-3-ERR_PKT_OVERSIZED ### Response: (Severity: 3), (Category: PLATFORM), (Description: PDMA SPP Transmit over-sized packet drop.), (Recommended Action: Execute spp_pdma_show_ltrace from the kshell of the card where this message was seen.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-GET_PATH_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cctl_proxy process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process cctl_proxy location <>' to verify that the process is up and running.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-GTRIE ### Response: (Severity: 3), (Category: ROUTING), (Description: FIB internally manages its prefix databases using generic tries. An error occurred while processing prefixes using the generic tries.), (Recommended Action: Try restarting the FIB process to see if the problem goes away. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HPI-4-ACCESS_WIDTH_NOT_MATCH ### Response: (Severity: 4), (Category: PLATFORM), (Description: PIO access to address with an different access width. It is possible to cause access failure.), (Recommended Action: Check the trackback and make sure the access is correct.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NAL-4-SUBSCRIBERS_AFI_DOWN ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This syslog is printed when the parent interface configuration is modified or parent interface is deleted and subscribers are present on that interface.), (Recommended Action: This is warning to alert the user that V4 or V6 AFI will go down for all IPOE sessions present on parent interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-SEM_OPEN_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Semaphore Open Failed while sending signal to CTRLIO.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-INVALIDINPUT ### Response: (Severity: 3), (Category: MGBL), (Description: 'The input is invalid. The calling function and the command are displayed'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_CLIENT_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: Ingressq client failed to Register/Unregister with Ingressq Server process. This error is also detected from the client's side. Retrial attempts would be made by the client.), (Recommended Action: 1. Verify the connectivity between the client and the Ingressq process. 'show controllers ingressq clients location <>' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_15_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_15 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-3-MMAPSHIFT ### Response: (Severity: 3), (Category: MGBL), (Description: The packet subsystem was not able to initialize memory.), (Recommended Action: The router will not start properly with this condition.\n' 'Call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UCP_LCTRL-7-ERR_INIT_SERVER ### Response: (Severity: 7), (Category: ROUTING), (Description: The ucp lctrl server could not be initialized.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-1-RX_MTA_FRM_LEN_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Ingress MUX encountered Rx serdes lane metaframe length error.), (Recommended Action: This fault would result in traffic loss. Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BPE-7-ERR_LWM_REPLY ### Response: (Severity: 7), (Category: PLATFORM), (Description: bpe LWM reply error), (Recommended Action: Please attempt to correct the error by restarting the process by issuing the command in exec mode -process restart bpe If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the function of the 'install rollback' command in Cisco IOS XR? ### Response: The 'install rollback' command in Cisco IOS XR is used to revert the router's software to a previous committed state, useful for undoing changes that may have caused issues. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different types of OSPF LSAs and their functions? ### Response: The main types of OSPF LSAs are\n- Type 1 Router LSA (lists all router's links/states in an area)\n- Type 2 Network LSA (generated by DR, lists all routers on a segment)\n- Type 3/4 Summary LSA (generated by ABR, advertises inter-area destinations and ASBRs)\n- Type 5 AS-External LSA (generated by ASBR, advertises external routes)\n- Type 7 NSSA External LSA (generated by ASBR in NSSA, converted to type 5 by ABR)\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Interrupt controller Driver encountered a fatal error and is not able to recover.), (Recommended Action: Please attempt to correct the error by restarting the process. Issue the command in exec mode -process restart longbeach If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDLPROD-3-MSG_SEND_FAIL ### Response: (Severity: 3), (Category: OS), (Description: A call to function for sending BCDL msg to consumers failed. This could lead to inconsistency between BCDL producers and consumers.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-1-ERR_PLANE_CONFIG ### Response: (Severity: 1), (Category: FABRIC), (Description: The fabric plane configuration for this multi-chassis system cannot be implemented with the hardware that has been discovered. This error may cause one or more fabric planes to stay down which will affect the bringup of the rest of the system. Possible causes could be incorrect admin plane configuration (ie the configuration states that slot 1 is the first card in a plane whereas slot 0 really is) or an incorrectly sized fiber module is inserted in a slot.), (Recommended Action: Check the admin plane configuration to ensure that it corresponds with the actual physical topology of the system. If this configuration looks correct then contact support, otherwise correct the configuration and the system should recover. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'allocate global' sub-command under 'mpls label range'? ### Response: The 'allocate global' sub-command is used to allocate labels from the global label pool. By default, IOS XR uses per-interface label space. The 'allocate global' command switches the label allocation to use the global label space, which is required for some MPLS applications such as L3VPN and MPLS TE. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-4-WARNING_INTERNAL_SW ### Response: (Severity: 4), (Category: FABRIC), (Description: The FGID Server encountered the annunciated SW error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-AUDIT_PROBLEM ### Response: (Severity: 4), (Category: LICENSE), (Description: The license manager encountered a problem during an internal audit. Check the error string to determine what has happened.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: ROUTING), (Description: Error in allocating memory.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-ALL_NPS_FAILED ### Response: (Severity: 0), (Category: PLATFORM), (Description: 'All active NPs on the line card have non-recoverable failures. The line card is no longer operational and will be reloaded.'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-5-SATELLITE_PORT_MESSAGE_RECEIVED ### Response: (Severity: 5), (Category: L2), (Description: A notification message has been received from a Satellite regarding the operational status of CFM on Satellite fabric links.), (Recommended Action: Depending on the content of the notification message, it may be necessary to adjust the CFM Satellite fabric link configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV6-3-WARNING ### Response: (Severity: 3), (Category: L2), (Description: A runtime error occurred in ASR9K IPv6 FIB module. The reason for the failure is also displayed. Please call Cisco Support with the error information.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace [common|ipv6] all loc <>). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-ERR_CONN_INIT ### Response: (Severity: 7), (Category: OS), (Description: An internal error was detected when trying to connect to the respective component.), (Recommended Action: When this issue happens, it will trigger an automatic restart. Check the status of the respective component because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_MCAST-2-ERR_DLL_INIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: A failure occurred during the initialization of the mpls mcast platform ingress netio DLL.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-3-UNLOCK_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: An error was encountered during deletion of the configuration lock. This configuration operation (e.g. save/restore configuration, CLI commit) is successful, but subsequent configuration operations could be affected by this error if not corrected.), (Recommended Action: Use 'show configuration lock' CLI to view the pending lock and 'clear configuration lock ' CLI to force deletion of it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-RX_ALARM_FRAME_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: For UTI mode alarm is raised if frame error rate exceeds 2%.), (Recommended Action: 1) Ensure valid BITS/UTI signal is applied at input port.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_8_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_8 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-TARGETNONE ### Response: (Severity: 3), (Category: SNMP), (Description: A configuration command refers to an SNMP target that has not yet been configured.), (Recommended Action: You must configure an SNMP target before you can refer to it. Examine your configuration. Ensure that the given target has been configured. If it has not, configure it. Copy the error message exactly as it appears on the console or in the system log. Issue the config command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the config output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-3-MISSING_RULES ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: IM is unable to create an interface/caps due to static information about the resource type being missing. The system may be in an inconsistent state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-PKTDROP_STR ### Response: (Severity: 3), (Category: ROUTING), (Description: An input packet was dropped for the specified reason.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN-6-FILE_EXISTS ### Response: (Severity: 6), (Category: OS), (Description: SHMWIN encountered an error condition, the file was existing already.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-LOCK_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: A lock operation on shared resource, called by nvgen failed due to the mentioned error.), (Recommended Action: Collect the output of show logging and inform Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-FLT_STACK ### Response: (Severity: 4), (Category: OS), (Description: Signal info.), (Recommended Action: No action required.Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RVM_MGR-3-ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Error message), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCONBKUP-6-INTERNAL_INFO ### Response: (Severity: 6), (Category: MGBL), (Description: This is a informational message indicating that cfgmgr debug logs have been collected during reload.), (Recommended Action: This is a info message. No action to be taken) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET_LOOPBACK-3-TRACE_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize trace in the platform Ethernet loopback component), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_1_PKT_MAXLEN_ERR_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet maximum length error on NPU-1 interface on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XCVR-3-DEBUG_INIT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message from the XCVR stating that failed to initialize a debug event type structure provided by the application with the supplied data), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_LIB-6-TEST_ISSU_RUN_RELOAD_SLEEP ### Response: (Severity: 6), (Category: INSTALL), (Description: Informs the user how many seconds the node is sleeping before reloading during a 'test ISSU-run' operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_TUNNEL_EA-3-INIT_ERR1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the CRS platform specific code software to indicate errors that happened during initialisation. This error is most likely caused by a temporary situation, so is unlikely to occur. %s - indicates the reason for the failure. %s - is the decoded error reason.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the function of the XML Management Interface in Cisco IOS XR? ### Response: The XML Management Interface in Cisco IOS XR allows for the configuration and monitoring of devices using XML over secure HTTP (HTTPS), providing a standardized and programmable interface. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-6-MEP_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: A CCM message was received from a new peer MEP, or a previously-known peer MEP timed out (i.e. its configured loss threshold was exceeded). This message appears because the service which the local MEP belongs to has continuity-check state change logging configured.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIAAPI-4-INVALID_PARM_FORMAT_PART ### Response: (Severity: 4), (Category: MEDIA), (Description: An invalid parameter value was passed to the driver to format and partition the media device.), (Recommended Action: Check the syntax for the the format command Report this message to TAC if the syntax and device are valid.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure inter-VRF route leaking in MPLS L3VPN? ### Response: To configure inter-VRF route leaking in MPLS L3VPN, use import and export route-target commands between VRFs. vrf MyVRF import route-target 65000:200 vrf MyVRF2 export route-target 65000:200 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-SI5347_PLL_LOL ### Response: (Severity: 3), (Category: PLATFORM), (Description: SI5347 PLL loss of lock detected/cleared for RSP), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_THREAD_MUTEX_LOCK ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error during locking of a RIP resource.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-4-DUP_REMOVE ### Response: (Severity: 4), (Category: SERVICES), (Description: The given attachment configuration, which was previously invalid due to duplicate attachments being configured on different interfaces, is now valid as the duplicate attachment configuration has been removed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_HQ_PKT_LEN_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue packet length error on XAUI 1 HQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYNCFS2LIB-7-MUTEX_UNLOCK ### Response: (Severity: 7), (Category: MEDIA), (Description: A required mutex unlock failed.), (Recommended Action: Contact customer support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2SNOOP-3-INIT_ERR ### Response: (Severity: 3), (Category: IP), (Description: An software error occurred while starting up of L2SNOOP process. If this occurred during process startup, then the process may be restarted.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-DEC_A_PKT_LEN_ERR_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Packet with invalid length encountered by decoder A on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-3-INTERNAL_PROBLEM ### Response: (Severity: 3), (Category: L2), (Description: An internal error has occurred, causing the feature to not be able to function properly.), (Recommended Action: The process is automatically restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-3-REASS_LIST ### Response: (Severity: 3), (Category: OS), (Description: The list of reassembly servers is incorrect.), (Recommended Action: Please try restarting pifibm_server_lc and pifibm_server_rp processes.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-PCI_DEV_RECOVERY_CB ### Response: (Severity: 3), (Category: OS), (Description: pci devices recovery cb messages), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAW_LIB-4-REBOOT_HIST ### Response: (Severity: 4), (Category: MEDIA), (Description: Information to collect the logs), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_2_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature less than or equal to the low temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CPAK with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-4-DUPLEX_MISMATCH ### Response: (Severity: 4), (Category: L2), (Description: CDP discovered mismatching duplex configuration on neighboring interfaces.), (Recommended Action: Configure the interfaces with the same duplex (full or half).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-2-CAL_CHIP_NOT_FOUND ### Response: (Severity: 2), (Category: MGBL), (Description: Unable to find calendar chip.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPM-3-ERROR_PTHREAD_INIT ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-EBS_OC_HDR_CRC_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: EBS from FIA header checksum error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FHRP_OUTPUT-3-WARN_COMMS_INIT ### Response: (Severity: 3), (Category: IP), (Description: The FHRP output process communications failed to initialize correctly. In this situation the FHRP output process retries the initialization, but may not recover if the failure to initialize persists. Clients of the FHRP output process (such as HSRP and VRRP) will not be able to send packets until the initialization succeeds.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-3-ARB_ECTW_RDATA_TO ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-6-SIGNAL_HANDLER_INFO ### Response: (Severity: 6), (Category: MGMT), (Description: This comes when registration of signal fails due to some system issue), (Recommended Action: The work-around is restart process would resolve the issue) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2CCTRL-2-MASTERSHIP_DENIED ### Response: (Severity: 2), (Category: PLATFORM), (Description: SMBus Mastership Denied by Bus-Master Mux), (Recommended Action: Please attempt to correct the error by reloading the card by issuing the command in admin mode -reload location <> If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR backup tunnel timers feature? ### Response: The MPLS TE FRR backup tunnel timers feature allows the configuration of hold and delay timers for backup tunnels. The hold timer specifies how long a backup tunnel should remain in place after the protected interface comes back up. The delay timer specifies how long to wait before installing the backup tunnel after the protected interface goes down. These timers help avoid unnecessary backup tunnel churn. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_LIB-3-INIT_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The SVI Adjacency Manager Library's initialization has failed. The process will exit and automatically restart.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_MEAS-3-CFG_PORT_FAILED_TO_OPEN ### Response: (Severity: 3), (Category: ROUTING), (Description: After several retries, the configured port has failed to open. The first argument is the name of the configured port and the second argument is the port number.), (Recommended Action: Configure a different port number. show udp brief will show which ports are already being used.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-4-IMDR_RESET_FAILED ### Response: (Severity: 4), (Category: L2), (Description: This is an error message in the PSE Driver to indicate that it failed to perform iMDR reset of specified pse instance due to the specified reason.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of OSPF areas and how do they help with scalability? ### Response: OSPF allows a network to be divided into areas. An area is a logical collection of OSPF networks, routers, and links that have the same area identification. Areas limit the scope of link-state advertisements (LSAs) and thus reduce the size of the topology databases on each router. This improves scalability in large networks. Areas must be connected to the backbone area (Area 0) via an Area Border Router (ABR). <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-CARD_POST_NOT_TRIGGER ### Response: (Severity: 4), (Category: PLATFORM), (Description: The card is reloaded due to a faulty HW/ASIC. The Online Diags process can't perform the required diagnostic testing on the falling device, hence the card will then be reloaded with XR image.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-6-PAK_SEND ### Response: (Severity: 6), (Category: ROUTING), (Description: Failed to send a packet. This can happen if other processes involved in packet forwarding are restarting. This may or may not be transient. If the packet which was not sent is HELLO then the EIGRP adjacency may flap if this issue happens long enough for the peer to detect a hold time expiry. If the packet which was not sent is a non-HELLO then the EIGRP adjacency may flap if this issue is seen long enough to exhaust the maximum number of retransmissions.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR-3-SYSDB_EDM_REG_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Procmgr failed to register with Sysdb EDM. This may be a program level error.), (Recommended Action: Provide the required information to support If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD-3-CPI_NOT_READY ### Response: (Severity: 3), (Category: PLATFORM), (Description: ClkCtrl driver detected a card cpi not ready condition), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_FPOE_DB_CORR_ECC_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast FPOE correctable ECC error on link 2), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IPV6_EA-3-FAILURE1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is a failure message in the ASR9K platform specific code software to indicate anomolies that are not serious failure. This failure is most likely caused by a temporary situation, so is unlikely to re-occur.), (Recommended Action: Please collect console log, traces * SH_CMD show af-ea ipv6 trace errors loc * Also notice if the failure message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_5_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_5 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP_GMP-4-WARN_INIT ### Response: (Severity: 4), (Category: IP), (Description: The ARP GMP process failed to initialize correctly. In this situation it restarts, but it may not recover if there is a persistant error in the IOSXR system and the ARP GMP is later unable to reestablish its connections and initialize successfully.), (Recommended Action: Try restarting the ARP GMP process. If the issue is seen repeatedly Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEMPOOL_EDM-1-SYSDB_REGISTRATION_FAILURE ### Response: (Severity: 1), (Category: OS), (Description: Sysdb registration failure), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-7-MMAP_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to mmap OIR registers.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-3-DATAPATH_CMD ### Response: (Severity: 3), (Category: OS), (Description: The given Pre-IFIB datapath control command returns error.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-CBC_WDOG_EXCEED_THRESHOLD ### Response: (Severity: 4), (Category: PLATFORM), (Description: Watchdog stats are collected on active RP.If watchdog toggle is not seen for long time, the message will be displayed.), (Recommended Action: Collect the output from RSP : admin show canbus server-stats location all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-STARTUP ### Response: (Severity: 7), (Category: SYSDB), (Description: A startup request failed during the second round of callbacks.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KIM-3-DEFAULT_ROUTE_CREATION_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: A failure occurred when attempting to create a default route in the TPA system for the specified vrf. Forwarding for TPA applications (including telemetry) will likely be impacted.), (Recommended Action: Restarting the kim process or unconfiguring and reconfiguring the VRF may be sufficient to recover. A switchover or router reload may be required if this condition persists. This error condition may sometimes be worked around by configuring the VRF to use the 'mgmt' default route. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OT-6-LIB_AVAIL ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-INCONSISTENT_CPUTUNES_CONFIG ### Response: (Severity: 3), (Category: OS), (Description: The virtual service machine definition file is requesting invalid CPU tunes parameter.), (Recommended Action: Use a different valid machine definition file for the virtual service. If the problem persists, then enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install activate auto-abort-timer command in IOS XR? ### Response: The 'install activate auto-abort-timer' command is used to set a timer for the automatic rollback of an installation if the user doesn't commit the changes within the specified time. This provides a safety mechanism to revert to the previous software set if something goes wrong during the installation. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_1_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Rx power less than or equal to the low Rx power alarm threshold. The QSFP+ is the pluggable optics on the line cards. The Rx power threshold values are read from the QSFP+.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-EBS_CPP_HP_FIFO_MBE ### Response: (Severity: 1), (Category: PLATFORM), (Description: EBS to CPP high priority FIFO multiple bits error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-BD_INVALID_LS_LAYER ### Response: (Severity: 3), (Category: L2), (Description: Unable to assign bridge domain because logical switch is not layer2 type.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-3-CORRUPT_INSTALL_FILE ### Response: (Severity: 3), (Category: INSTALL), (Description: An install file is corrupt. This may affect the system in a number of ways including preventing nodes from booting and preventing install operations.), (Recommended Action: First attempt to repair the file using 'install verify repair', this is this least impactful operation. If that is unable to repair the file then if possible 'install remove' the package associated with the file and then 'install add' the pie containing the package. If the file is still corrupt then use a pre-prepared backup disk if available to revert to a previously known good set of software, or failover to standby nodes to start using their set of software files.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_FIND ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_IPC-3-SYSDB_LIST_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The message indicates the failure while updating the data items in the system database.), (Recommended Action: Please collect the console log and CLI output. Copy the error message exactly as it appears on the console or in the system log. Issue the cmd command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the cmd output, call your Cisco technical support representative and provide the representative with the gathered information. show cef show cef location <> show cef trace location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISLM-4-SESSION_THRESHOLD_EXCEEDED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This syslog is printed when the configured session threshold has been exceeded.), (Recommended Action: This is warning to alert the user that sessions may be near the limit that is configured or entitled.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_CLIENT-3-INIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A failure has occured in the FPD Client during process initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: T1E1_LNM-3-REMWARNNOISE ### Response: (Severity: 3), (Category: L2), (Description: Noise on the link has either crossed or fallen below the threshold value configured by the user for link removal on the controller identified in the message. Video or voice quality may be affected if noise is above the configured threshold.), (Recommended Action: This link requires administrative attention. If noise is at or above the configured threshold, only applications such as MLPPP bundles support automatic removal of links from bundles. For other applications, the administrator may need to remove/replace this controller from service. If noise is below the configured threshold and was previously taken out of service by the administrator, the administrator may choose to put this link back into service or wait until noise has fallen below minor-warning level threshold. For an MLPPP link, this will be done automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-SLOT_SPECIFIC_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that an operation to get Card Control Block CCB for specific to a slot has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TZ-3-INTERNAL ### Response: (Severity: 3), (Category: OS), (Description: Serious problem occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-EVENT_CONN_ERROR_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: After detecting an error with the connection to the specified service, IS-IS failed to reset that connection. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-4-INIT_ERROR ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: bfm encountered a error and is not able to recover from the error trying again. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-BAG_ENCODE_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to encode a bag.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEv2-6-KEYRING_NOT_FOUND ### Response: (Severity: 6), (Category: SECURITY), (Description: Keyring not found in IKEv2 profile.), (Recommended Action: Configure and attach keyring to IKEv2 profile.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PHYS_COMMON-6-AINS_STARTED ### Response: (Severity: 6), (Category: L1), (Description: The notification Indicating Successful (Re)Start of Automatic In-Service Soak Timer), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-6-RP_ISOLATION_RESET_REQ ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message indicating that RP Isolation is in force, CPU reset request for the target slot is ignored.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-3-FAILED_TO_ACCESS_KSH_REPARTITION ### Response: (Severity: 3), (Category: PLATFORM), (Description: Some existing eUSB may have wrong FS or partitions. Check if need to reformat the eUSB. This message will get printed if there is failure in accessing the Ksh to repartition eUSB.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIER-0-PCIE_FAB_FATAL_ACCESS_ERR ### Response: (Severity: 0), (Category: PLATFORM), (Description: A PCIE (fabric block) access error was detected for controller Card. The error prevents this card to perform some vital tasks making it unusable), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-SOCK_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An operation failed during socket initialisation.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-NOTIF_REGN ### Response: (Severity: 3), (Category: OS), (Description: Unable to register for event_item with sysdb.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support sysdb command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support sysdb output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_11_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-6-CLOSE_ENET_DEVICE_INFO ### Response: (Severity: 6), (Category: OS), (Description: Faliure to close the connection to ethernet server.), (Recommended Action: Informational message) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-6-DBEXIST ### Response: (Severity: 6), (Category: ROUTING), (Description: OSPF has an invalid duplicate copy of an LSA, which could lead to a memory leak.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the additional following commands: - show ospf database - show ospf trace all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AIB_CLIENT-4-ADJ_SANITY_CHK ### Response: (Severity: 4), (Category: ROUTING), (Description: AIB entries have somehow set REMOTE_FLAG for TX ADJ. This should not happen - remote flag should only be set for RX ADJ.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS_MODULE-2-DEV_OPTICS_SUPPORTED_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: An supported error was detected during optics initialization. This error is reported when the optics type can not be determined or it is not supported on the platform. The optics is the pluggable optics on the line cards.Optics initialization may happen when linecard boots up, optics OIR and line card process restart. The optics will not be enabled if an optics supported error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the optics with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NCS4K_4H_OPW_QC2-3-THRD_ACCESS_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: THRD Access failed), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-NPU_0_FC_OOS_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress flow control out-of-sync on NPU-0 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-6-OPTICS_INSERTION ### Response: (Severity: 6), (Category: L2), (Description: Optics module has been inserted. %d - indicates the bay number), (Recommended Action: None. This is an informational message only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-PTHREAD_DETACH ### Response: (Severity: 3), (Category: OS), (Description: PlaceD daemon was unable to detach the thread. Recovery occurs with automatic process restart.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-BAD_PIE_FORMAT ### Response: (Severity: 7), (Category: INSTALL), (Description: The PIE file is in an obsolete format or is unknown.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-UNKNOWN_BOOT_REQ_MSG_VER ### Response: (Severity: 3), (Category: PLATFORM), (Description: Shelf manager received a version of boot request message that it cannot support.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_7_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power greater than or equal to the high Tx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSVP-5-MAM_MAX_RES_BW_NO_VALUE_DEPRECATE_NOTICE ### Response: (Severity: 5), (Category: ROUTING), (Description: Interface bandwidth mam max-reservable-bw is being configured without \ specifying a value. This is not supported in XML and YANG models.), (Recommended Action: Use the 'mam [percentage] max-reservable-bw '.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-PKT_LEN_ERR_1_FIA_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet length error from FIA for NPU-1 on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'area default-cost' command in OSPF? ### Response: The 'area default-cost' command is used on an Area Border Router (ABR) to specify the cost of the default route that it generates into a stub or NSSA area. By default, the cost is 1. Increasing this value makes the default route less preferred. This is useful for controlling how traffic from the stub or NSSA area exits the area when there are multiple ABRs. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_DISC-6-PAK_MEM_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Find out physical memory information from SYSPAGE. If more memory is found than our defined minimum MIN_RESERVED_MEM, then a scaling factor is created to scale the number of packets, particles, etc, upward. Packet memory information like size, starting, scaling are shown), (Recommended Action: Information message only no action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-6-OPENERROR ### Response: (Severity: 6), (Category: MEDIA), (Description: Check the state of the device pointed by path. Device may be inaccessible.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-3-OPTICS_FPD_UPGRADE_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Unable to complete FPD upgrade for the Optics due to an internal software or Hardware error. The error message describes the error.), (Recommended Action: Move the Optics to Laser Shut State before performing FPD Upgrade and do the Optics OIR or MPA reload to recover the Optics from Fault state. If the issue occurs under other conditions, then copy the error message exactly as it appears on the screen and collect console log and - sh platform - sh install summary - sh version - show tech-support ethernet interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-ASIC_FMEA ### Response: (Severity: 3), (Category: FABRIC), (Description: Asic FMEA Fault Report), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_CONFIG-7-ERR_MUTEX_INIT ### Response: (Severity: 7), (Category: OS), (Description: A internal mutex operation has failed. This is a bug.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_14_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-RESET_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected an error. Device is not coming out of reset.), (Recommended Action: Please contact technical support If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB-5-ltrace_init_error ### Response: (Severity: 5), (Category: PLATFORM), (Description: fpoe: ltrace_init2 for errors trace failed.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_0_ERR3_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 0 ran into error-3 on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_WAVL_INIT ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an unexpected error which prevents it from functioning. This error may be caused by low memory resources. The process will abort and be restarted in an attempt to recover.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDLTLV-6-MSG_GENERIC_ERROR ### Response: (Severity: 6), (Category: OS), (Description: BCLS TLV processing hit some error condition.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-ENGINE_TIMER ### Response: (Severity: 3), (Category: L2), (Description: An error occurred while processing the engine thread timer wheel. This may cause CCMs not to be sent, or peer MEPs not to time out after the configured loss time.), (Recommended Action: The process may recover after 60s. If the problem persists, it may be possible to recover by restarting the 'cfmd' process on the node where the problem occurred.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_EVC_CREATE ### Response: (Severity: 4), (Category: L2), (Description: PPP MA failed to create a connection to an essential service during initialization. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_HFR-7-ERR_EVENT_CONN_NOTIFY ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to register event handler for disconnection or connection error event. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-FILE_SYSTEM_SWITCHOVER_PERFORMED_PRE_RELOAD ### Response: (Severity: 6), (Category: INFRA), (Description: When applying some versions of software, it may be necessary to update the file system to use the new software before a reload is performed. Any processes that were already running, will continue to use the old software until the reload has been performed. Any processes that are (re-)started will use the new software and meta-data. The new software may be incompatible with the older software, and so any communication between new processes and old processes cannot be guaranteed to be compatible, increasing the chances of an abnormal restart. It is recommended to not perform any operations, via any manageability interface, until the system has reloaded - unless specifically requested.), (Recommended Action: Do nothing, until the system has reloaded.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND-3-ERR_MPLS_ATTR_GET ### Response: (Severity: 3), (Category: IP), (Description: Cannot determine whether MPLS is enabled or not on the interfaces), (Recommended Action: Restart IPv6 ND) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-6-TRANSCEIVER_ENABLED ### Response: (Severity: 6), (Category: L2), (Description: This informational message indicates that the optic interface module was enabled on the given interface after 'no shut' was applied to the optical controller.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-1-FC_OIR_ALERT ### Response: (Severity: 1), (Category: PLATFORM), (Description: 1) An alarm has occured. The Fan Controller card has been removed. 2) A previously occured alarm has been cleared. The Fan Controller Card has been re-inserted.), (Recommended Action: Two possibilities to this message. 1) An alarm has occured : Insert the Fan Controller Card. 2) A previously occured alarm has been cleared : *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAAD-2-CRITICAL_ERROR ### Response: (Severity: 2), (Category: MGBL), (Description: A critical error was encountered. The failure of this can be critical to general system operation. If the same error is seen more than 5 times, contact Cisco TAC support because a reboot of the node may be required.), (Recommended Action: Provide the message details to Cisco Support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEV2-7-VERIFY_APPLY ### Response: (Severity: 7), (Category: OS), (Description: A sysdb verify/apply callback information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLICE_MGR_PROXY-3-CAPI_CONNECTION_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Connection to mentioned CAPI service failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-6-DELETE_SHIM_ENTRY ### Response: (Severity: 6), (Category: L2), (Description: Debug Information - Deleting shim info entry for the given interface handle), (Recommended Action: *None*.Informational message only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-PAKMAN_EVENT ### Response: (Severity: 4), (Category: ROUTING), (Description: An error has occurred and pak manager sent us an event. If we can't recover from the error (ABORT event), OSPF will exit.), (Recommended Action: This is an indication that error(s) has occurred in pakman No specific actions are required for OSPF.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-TARGET_CFG_LOCKERR ### Response: (Severity: 3), (Category: MGBL), (Description: Config process failed to obtain exclusive lock for this session. Terminate the other open sessions and try again.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-NH_LOCK_RECURSIVE ### Response: (Severity: 3), (Category: ROUTING), (Description: A software error has occurred whilst trying to lock a nexthop entry in the BGP nexthop Table database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-6-INVALID_ADDRESS ### Response: (Severity: 6), (Category: IP), (Description: 'The call to ip_addr_c_get_v4/v6_best() returned an invalid address'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD-4-WARN ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is a warning message from FPD operation.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-NO_HB_RECEIVED ### Response: (Severity: 4), (Category: PLATFORM), (Description: This indicates that something is wrong in shelfmgr's ability to receive Heart Beats, OR there are simply no cards sending HBs.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_2_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHEMA-7-INTERNAL ### Response: (Severity: 7), (Category: MGBL), (Description: An internal error has occurred in the schema server or library. Some management functions may not operate correctly.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-REDIST_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: The RIB returned an unexpected error when IS-IS attempted to (de)register for the redistribution of routes in the specified topology and owned by the specified protocol. If this is a registration error then routes from the specified protocol may not be advertised in IS-IS's system LSPs. If this is a deregistration error then IS-IS may receive unnecessary redistribution updates from the RIB but the system LSPs will be correctly generated. The problem may be caused by a low memory condition but is most likely to be an internal programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the IS-IS and/or the RIB processes. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_IFM-3-WARN_LIB_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: A failure occured in the CPP IFM Library that may affect the functionality of CPP.), (Recommended Action: *SH_CMD debug controllers pse qfp interface ifm all all * *SH_CMD show controllers pse qfp interface ATM R/S/I/P info * *SH_CMD show controllers pse qfp interface ATM R/S/I/P location < > * *SH_CMD show controllers pse qfp interface ATM R/S/I/P statistics *) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-DP_MUX_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: DP MUX read/write access failure/success), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-2-ENFORCE_GRACE_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature is still enabled after grace period.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_7_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_CLI-7-BAD_BUFFER ### Response: (Severity: 7), (Category: HA), (Description: A NULL pointer was encountered unexpectedly.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATSD-3-EVENT_BLOCK ### Response: (Severity: 3), (Category: MGBL), (Description: The event handling function returned an error which could not be handled), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-2-HEADLESS_RSP_DETECTED ### Response: (Severity: 2), (Category: PLATFORM), (Description: This card has stopped receiving heartbeat messages from the RSP. It will therefore reset itself as it can not communicate properly with the RSP.), (Recommended Action: Please collect the following information and contact your Cisco technical support representative. 1. The console output of the active RSP from user login till the end. Please make sure the above error message(s) are included. 2. (admin)#show install trace mbi-hello location 3. The output of the following CLI commands:) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_16P_OC48-3-DEVICE_INTR_CLEAR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The previously reported excessive interrupts condition has been cleared. Interrupt rate limiting has been disabled.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-3-RELOAD_TIMED_OUT ### Response: (Severity: 3), (Category: INFRA), (Description: Router did not reload within expected duration after image was installed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCCLASS-3-PRODUCER_HDLR ### Response: (Severity: 3), (Category: MGBL), (Description: A failure occurred in the ATM VCCLASS producer handler while processing requests from the consumer.Internal failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-WATCHER_THREAD_INIT ### Response: (Severity: 3), (Category: HA), (Description: An error occured when attempting to initialize the cpu watcher thread.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMS-7-MISSING_NODE_NFN ### Response: (Severity: 7), (Category: SYSDB), (Description: No node down notification was received from the underlying infrastructure for a recent node reload.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SDT_SHOW-7-NODE_PRINT ### Response: (Severity: 7), (Category: OS), (Description: The show helper was unable to decode a text name for the node id a given trace block containing string data came from. As a result of this, the given trace will not be printable.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTP7 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-PEERSEXIST ### Response: (Severity: 3), (Category: ROUTING), (Description: One or more peers exist on an interface which is being deleted and hence the interface may not be deleted completely in EIGRP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_REDDRV-6-SKIPPING_RESET_STANDBY ### Response: (Severity: 6), (Category: PLATFORM), (Description: Skipping an API reddrv_reset_standby when rmf reference is removed.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON_PROXY-3-INVENTORY_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon Proxy process failed to initialize. The System Manager will restart the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, error), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR-6-NOT_SUPPORTED_CARD_TYPE_NG ### Response: (Severity: 6), (Category: PLATFORM), (Description: This command is not supported on RSP880/A99-RSP/RP2 card.), (Recommended Action: 'Please use show controllers epm-switch location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-4-NODES_DROPPED ### Response: (Severity: 4), (Category: INFRA), (Description: The install orchestrator has not been able to confirm some nodes after a user requested apply by reload. The ongoing transaction will continue without these nodes. Once the transaction is committed, they will no longer be held down. If they come up with software that does not match that of the active RP, they will then be reimaged.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-CPIF_SCSM_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected SCSM multi-bit error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ERR_DLL_UNKNOWN_FUNC ### Response: (Severity: 3), (Category: MGBL), (Description: 'An error occurred when trying to locate the dll function in DLL.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the main steps performed by the TURBOBOOT process? ### Response: The main steps performed by TURBOBOOT are\n1. Checks the size of the boot device to ensure sufficient space\n2. Cleans up the boot device by deleting old files and directories\n3. Copies the packages from the .vm file to the boot device\n4. Creates necessary directories and links on the boot device\n5. Validates the packages and generates an inventory\n6. Hands over control to the System Manager (sysmgr) to start the IOS XR processes\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-3-SERVER_CONNECT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: A communication problem occurred between the MBI client and server, perhaps because the communications infrastructure is not yet up. The MBI operation in progress will not be carried out.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_4_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-NH_CLIENT ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occured when trying to clear redist information for a client.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-FPGA_MEMORY_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC FPGA detected memory errors . Although its rare to encounter these errors,it impacts CCC FPGA functions. During these errors being experienced by CCC FPGA there are possiblbities of read/write issues to CCC FPGA registers. Also alarms shall be raised by envmon for sensor related accessibilities as CCC FPGA wont be accessible due to errors), (Recommended Action: Try reloading the card using 'hw-module location <> reload'. If multiple card reload operation cannot fix the problem, check if physical OIR can address the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does SysDB help achieve high availability in IOS XR? ### Response: SysDB contributes to high availability in several ways\n- Config and persistent state are replicated between active and standby RPs\n- Processes can resynchronize their state from SysDB after a restart\n- Processes can register for notifications to detect config changes and operational state updates\n- Schema enforcement and config validation prevent invalid state from being propagated\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-ATTACH_PORT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath encountered an initialization error), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect show log location output, show controllers dpaa trace all location output and show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-MLACP_RESYNC_INCONSISTENCY_DISCONNECT ### Response: (Severity: 5), (Category: L2), (Description: A resync failed to solve an inconsistency and so the local device has disconnected.), (Recommended Action: Disable and re-enable mLACP on either the local or the peer device.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATMSNMP-3-IFMGR ### Response: (Severity: 3), (Category: SNMP), (Description: A high severity error is encountered. The error relates to an interaction with interface manager.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-4-DUP_CREATE_ERR ### Response: (Severity: 4), (Category: SERVICES), (Description: An error has occurred processing an invalid configuration whereby the same service attachment has been configured on two or more interfaces (which should result in both attachments being viewed as failed and moved in to failure state). Packet diversion may now be inconsistent. The error string will give more detail on the type of error that has occurred.), (Recommended Action: For non-resoucre errors, removing the initial misconfiguration may remove this error. If the error is a resource error this will be indicated in the error description given. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATSD-3-REGISTRATION_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: Registration of a stats collector with stats server failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_DYNREG-3-AP_UNREGISTER_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered as old attach point data was being unregistered for new data. As a result, the registration for the old data is still activated for this attach point. As this point is would be best to restart the policy_repository to try to clear this inconsistency.), (Recommended Action: Restart the policy_repository process and check for re-occurence of issue If problem persists, the please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-META_OPER_WRITE_ERROR ### Response: (Severity: 7), (Category: OS), (Description: An OBFL internal record type write failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_EEC2 ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from EEC2.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-2-ENFORCE_EVAL_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature has been used exceeding evalution period.), (Recommended Action: The customer should either register for license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_UTIL-7-COLD_RESTART_IGNORED ### Response: (Severity: 7), (Category: HA), (Description: The process has failed to restart multiple times. By design, the process will continue to restart with its existing CDM data.), (Recommended Action: Analyze the restart failure and take appropriate recovery action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-7-PARTIAL ### Response: (Severity: 7), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-2-PCIE_FAB_FATAL_ACCESS_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PCIE (fabric block) access error was detected for controller Card. The error prevents this card to do traffic switching thereby making it unusable), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO_COMMON-3-SYSMGR_FAIL ### Response: (Severity: 3), (Category: L2), (Description: The process has failed to inform System Manager that it is shutting down. The process will exit anyway, but it is possible that any configuration entered will not cause SysMgr to restart the process. In this case, a timeout will occur when committing configuration, and the config will fail to apply.), (Recommended Action: If configuration fails to apply, recommitting it should correct the issue. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_5_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPIO_PD-3-GET_MY_NODE_ROLE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Node role look-up failed. Packet path initialization at RP errored.), (Recommended Action: Restart the spio_ma process. 'process restart spio_ma location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CMPP-4-LOST_EVENT ### Response: (Severity: 4), (Category: INFRA), (Description: The specified process failed to receive an event that was sent to it.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-1-ERR_HW_RESET_PLL ### Response: (Severity: 1), (Category: L2), (Description: A hardware error is detected on the PLIM. Software will take action as described in the error message, if not none, to try to recover from the error. The hardware error and the software recovery action will not impact traffic. Device: %s%s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Software action: %s - the action that software will take to try to recover from the error. Recommended user action: %s - recommended action to the user. Possible values: 'none' 'replace XFP' 'PLEASE MANUAULLY RELOAD THE LC AT NEXT MAINTENANCE WINDOW'), (Recommended Action: Take the recommended user action as it is described in the error message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-UNSUPPORTED_FORMAT ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: XRd currently only supports interface names with the format of a physical, non-satellite interface.), (Recommended Action: Check the format of the interface names in the XR_INTERFACES environment variable.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-BAD_AVPAIR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_BQS-6-SRTMEMLOW_DECLARE ### Response: (Severity: 6), (Category: L2), (Description: CPP BQS HW schedule resources have dropped below critical threshold.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEA_DLL-3-CHKPT_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: After a process restart, an error was encountered while recovering checkpoint memory/database. The running-configuration and hardware programming may be inconsistent. Problems may be encountered with future configuration changes as well.), (Recommended Action: Try to manually restart pfilter-ea. If the problem/log persists, a reload of the line card is necessary. Get the JID from 'show processes location <>' 'process restart JID location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT-0-FATAL_FAULT ### Response: (Severity: 0), (Category: PLATFORM), (Description: TX PLL inside the FPGA device is not locked.), (Recommended Action: The software is not able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_NTP-5-STATE_CHANGE_TO_UNSYNC ### Response: (Severity: 5), (Category: IP), (Description: when the node state change to unsync with the ntp server.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FT-3-IDPROM_ACCESS_FAILED ### Response: (Severity: 3), (Category: LIBRARY), (Description: Software cannot read the fan tray's IDRPOM.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_PAIRING-3-NO_PROC_READY ### Response: (Severity: 3), (Category: PLATFORM), (Description: Drp_pairing process failed to notify cfgmgr that it is now ready to accept admin config), (Recommended Action: Collect the console error messages exactly as it appears on the console and call cisco support engineers with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_SFRAR-2-INIT ### Response: (Severity: 2), (Category: L2), (Description: During process start up an unrecoverable error occurred. The component will exit and should be restarted by the System Manager. Once restarted, it should work fine. The performance will be affected in the only manner that the Static Frame Relay Address Resolution will not be initialized in the worst case.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_VPLS-6-DEBUG_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB VPLS component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BAG_SCHEMA-4-ERR_EVM_CREATE ### Response: (Severity: 4), (Category: INFRA), (Description: Bag Schema Server failed to create its Event Manager which is a critical resource for the operation of the process. This error may be caused by low memory resources. The process will abort and be restarted in an attempt to recover.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHER_CTRL-3-IF_OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBIPV4PROTO-7-GET_PAK_HDR_COUNT ### Response: (Severity: 7), (Category: IP), (Description: There was a problem while getting total packet header count for this node.), (Recommended Action: This could happen if there is a problem with packet shared memory on the node. The transport would restart in this situation, if it restarts once or twice and then recovers, then it could be a transient problem and no action is required. If the transport keeps restarting, do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_SERVER-6-UPGRADE_RESULT ### Response: (Severity: 6), (Category: INFRA), (Description: Update FPD upgrade Status), (Recommended Action: The reason for failed FPD upgrade to be analyzed. Please contact Cisco Technical) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-3-NETLINK_SOCK_HAS_NO_NETNS ### Response: (Severity: 3), (Category: INFRA), (Description: The Netlink module contains a dictionary which maps each open Netlink socket to a network namespace file descriptor. The module attempted to look up a socket whose file descriptor is not present in the dictionary.), (Recommended Action: If the problem persists, restart the process. If the problem persists through restarts, Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-RACK_DECODE_FAILURE ### Response: (Severity: 7), (Category: OS), (Description: An error happened for a rackid decoding.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-5-OIROUT ### Response: (Severity: 5), (Category: PLATFORM), (Description: Detected a card is removed from the chassis.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-BAG_ENCODE_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVM-1-QSM ### Response: (Severity: 1), (Category: OS), (Description: A call to the QSM API failed. The server was not able to advertise itself.), (Recommended Action: This is an internal error and should be reported to TAC. The application process making the call has corrupted data or some other internal error. The application should be restarted; if that fails, the router should be rebooted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEAT_MGR-3-MATCH_TYPE_IN_ACL_NOT_SUPPORTED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The following match criteria specified in an ACL are not supported as part of a QoS policy: Packet Length, TTL, TCP Flags.), (Recommended Action: remove the match criteria from ACL and re-apply) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-3-RUNNING_ON_NON_PERSISTENT_DEVICE ### Response: (Severity: 3), (Category: INSTALL), (Description: A Managed node is running software from a non persistent device when it was instructed to use a persistent device at bring up time. Persistent device not available so software will be stored in memory. Expect longer boot times. The node will continue to operate on a best-effort basis but should be looked at soon. You may see out-of-memory errors and problems with package activations on the node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_OUT_MEM_CORR_ECC_ERROR_LNK3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast output memory correctable ECC error on link 3), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSHD-3-ERR_MALLOC ### Response: (Severity: 3), (Category: IP), (Description: The server has failed to acquire the required amount of memory), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM-4-ERROR_RUN_BMON ### Response: (Severity: 4), (Category: MEDIA), (Description: pthread_create() returns error. This error occurs when mapping of PLD register for reading NVRAM battery state is failed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBSOC-6-BIND_INFO ### Response: (Severity: 6), (Category: OS), (Description: Print socket bind info.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-7-CSPF_FALLBACK ### Response: (Severity: 7), (Category: OS), (Description: A disjoint path couldn't be found.), (Recommended Action: Check network redundancy.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-3-EVENT_CONN_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The IPV6 MA process failed to initialize its event conn mgr infra.), (Recommended Action: Restarting ipv6_ma may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UCP_OLM-7-ACTIVE_IPCC_AVAIL ### Response: (Severity: 7), (Category: ROUTING), (Description: An IPCC has come back up or newly configured for a neighbor.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-3-ERR_DEBUG_REGS ### Response: (Severity: 3), (Category: FABRIC), (Description: Crab debugging registration failure. Its debug infra init failure. May not be related to PD.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PDMA_SPP-3-ERR_THREAD ### Response: (Severity: 3), (Category: PLATFORM), (Description: PDMA SPP Thread Error message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-UNEXPECTED_STATE ### Response: (Severity: 6), (Category: L2), (Description: Whilst parsing a variable response packet an invalid state was found. This could be an indication of a faulty implementation on remote peer.), (Recommended Action: No specific IOS-XR action needs to be performed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSEC_SVI_EA-3-STATE_CHANGE ### Response: (Severity: 3), (Category: SERVICES), (Description: While the IPSec SVI EA process was checking the state for the specified interface, an error was encountered. The interface in question may be left in an inconsistent state.), (Recommended Action: It may help to restart the IPSec SVI EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEv2-6-AUTH_SUCCESS ### Response: (Severity: 6), (Category: SECURITY), (Description: IKEv2 peer is successfully authenticated using any of the configured remote methods), (Recommended Action: No Action Required) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_FPGA-3-ERR_HW_HARD_RESET ### Response: (Severity: 3), (Category: L2), (Description: A hardware error is detected on the Datapath FPGA. Software will take action as described in the error message to try to recover from the error. The hardware error and the software recovery action will cause hard reset of a device in the data path and will impact traffic. Device: %s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Software action: %s - the action that software will take to try to recover from the error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_0_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM_PD-6-REPLAY_EVENT ### Response: (Severity: 6), (Category: L2), (Description: The recent create/update event for the bundle has triggered validation which resulted in BMT misprogramming.This has resulted in replay call for the bundle.), (Recommended Action: Replay event will correct the corruption.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ACL-4-IPACCESSUNSUPPORTED ### Response: (Severity: 4), (Category: ACL), (Description: An access list that contains object-groups in one of its entries was specified. At this time ACLs with object-groups are supported only for packet filtering. I.e., attached to an interface.), (Recommended Action: Specify an access list that does not specify any object group in any of its entries.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN-4-DB_DELETE_FAILED ### Response: (Severity: 4), (Category: L2), (Description: SPAN was unable to remove an object from its database. The process will attempt to recover, but it is possible that traffic will not be replicated correctly, or some traffic will not be replicated to the correct interfaces. Standard forwarding will not be affected.), (Recommended Action: This is likely to indicate an internal inconsistency in SPAN. The problem may be resolved by issuing 'process restart' for the affected process on the node that emitted the message. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-5-ERR_TCAM_PREFIX_COMPRESS ### Response: (Severity: 5), (Category: OS), (Description: IPv6 prefix compression failed because the line card has run out of internal resources for compressing a preifx. It shouldn't have any major impact on the system service. The in-bound (destined to the system) packets can still reach destinations through SW path.), (Recommended Action: Try either change the prefix length or change the prefix value of IPv6 addressses used in the system if possible.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BOOTVAR-7-CANT_OPEN ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the NVRAM file system is in error, or the boot-variable infrastructure is behaving incorrectly. A file required for carrying out the current request or operation could not be opened, so processing of the operation will halt. The boot variables may not be available to the system.), (Recommended Action: Check NVRAM filesystem for corruption using the 'fsck' disk check CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-ERR_ALM_ONE_LABEL ### Response: (Severity: 3), (Category: ROUTING), (Description: The ALM/LSD API was unable to allocate a requested label.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-0-CRC_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: CRC rate above acceptable level), (Recommended Action: Gather the data listed in 'required_info'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-7-ERR_LRD_EVENT ### Response: (Severity: 7), (Category: MGBL), (Description: Registration to LRd failed.), (Recommended Action: Restart parser_server process after all cards come up.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-SPA_HW_ERR ### Response: (Severity: 4), (Category: L2), (Description: SPA hardware detected errron on the PLIM. For this no software action is needed.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_7_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_7 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_RELOAD ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver encountered an error when trying to reload. The card cannot be reloaded at the time of the message. Fabric driver may retry again when resources and conditions are met. The card and its fabric ASICs should have been isolated from the system.), (Recommended Action: Check the health of the shelfmgr process on the dSC RP. If shelfmgr is healthy, and the card does not reload after waiting for minutes, reload the card with the following command in admin mode: 'reload loc 0/SMx/sp', where x is the SM module number that generated the error. If manual reload does not work, or if the error recurs, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-SATELLITE_UNEXPECTED_NOTIFICATION ### Response: (Severity: 3), (Category: L2), (Description: An unexpected notification was received for the given Satellite. CFM may fail to function correctly on the Satellite affected.), (Recommended Action: If the error is the result of a configuration change, remove and reapply the configuration. If this does not work, or the error was otherwise triggered, then try restarting the CFM Daemon using the 'process restart cfmd location ' command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-6-BAY_OPTICS_OIRIN ### Response: (Severity: 6), (Category: PLATFORM), (Description: OPTICS enity is inserted into the line card), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6-4-EVENTCONN_CREATE_FAILED ### Response: (Severity: 4), (Category: IP), (Description: The IPv6 IO process failed to create a connection to a server), (Recommended Action: Restarting ipv6_io may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ST16550-3-INTERRUPT_UNMASK_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The ST16550 UART driver has been unable to unmask the UART interrupt.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_OPTICS_PWR_SUPPLY_ALARM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_LQ_SEQ_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue sequence error on XAUI 0 LQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FRAG-7-INIT_ERR ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: The Fragment Reassembly Plugin encountered a fatal error during initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-NP_PERF_INFO ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: CPUCtrl Driver encountered an initialization error and may not operate correctly. The supplied text string will explain the reason. Call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-INTF_PARAMS_FAILURE ### Response: (Severity: 3), (Category: SECURITY), (Description: [1] When an interface is configured with a VRF that is not configured globally, it is treated as invalid VRF. SAs should not be created on this interface. [2] When an interface state is not UP SAs should not be created on this interface.), (Recommended Action: [1] 'Make sure to use interfaces with valid VRF' [2] 'Make sure to use interfaces with state UP') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STREE-4-CONNECT_FAIL ### Response: (Severity: 4), (Category: L2), (Description: stp_process is most likely in a bad state or basic system services have failed. stp_process error messages are generally indicative of health of control-ethernet which is critical for system operation. Misbehavior of stp_process can cause instability in the system.), (Recommended Action: Sysmgr process will restart the stp_process if it encounters this error. Check if the 'stp_process' is up and running if this error is encountered. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-EDM_CLIENT ### Response: (Severity: 3), (Category: ROUTING), (Description: CLNS EDN client (usually a show command) failled to perform certain operation.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-6-NHDB_OUT_OF_SUBNET ### Response: (Severity: 6), (Category: ROUTING), (Description: The nexthop of a static route is outside of outgoing interface. This is an invalid configuration.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-3-ERR_THREAD_FN ### Response: (Severity: 3), (Category: SECURITY), (Description: The call to pthread functions, such as pthread_create, lock/unlock a mutex or wait on a condition, failed. The error is displayed in the message.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_TOPAZ-3-ERR_QAD_EGRESS_QUEUE_MISSING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to find the qad queue for egress packets. This could causes applications using this qad queue not sending out packet %s - QAD queue name %s - thread name), (Recommended Action: Reload the card. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-TIMESTAMP_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: An unexpected error occurred whilst recording a timestamp. This implies an internal programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CATAPULT-3-ERR_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in CATAPULT Driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-6-SESSION_USAGE_THRESH_EXCEEDED ### Response: (Severity: 6), (Category: PLATFORM), (Description: Sessions have exceeded 90% threshold Details will be given in the meesage displayed), (Recommended Action: Reduce number of sessions for this particular user.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-REPLY ### Response: (Severity: 7), (Category: SYSDB), (Description: The server failed to reply to a client request. A likely reason for this is that the process in question has exited.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show process location all command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show process location all output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCMD-4-INV_DIAG_CONFIG ### Response: (Severity: 4), (Category: ROUTING), (Description: Invalid configuration exists for non-linecard location. Diagnostics configuation can be only for linecard slots.), (Recommended Action: Please remove the invalid location from under RCMD diagnostics configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSMLIB-4-EXIT_ON_ERR ### Response: (Severity: 4), (Category: L2), (Description: An error occurred in the PSE ASIC client library after which the client code cannot continue. This error is encountered when a client module (e.g. cli command) has difficulty retrieving information from the PSE driver. The root cause may be located in either hardware or software.), (Recommended Action: *RECUR* Copy the error message exactly as it appears on the console) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: sIMP-4-ITI_WARN ### Response: (Severity: 4), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-4-BOARD_POWERUP_WARN ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message is just an warning of different group id in IDEEPROM. Currently this warning can be ignored and continue with the warning.), (Recommended Action: No action required. Ignore this warning.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-4-UPGRADE_ALLOWED ### Response: (Severity: 4), (Category: LICENSE), (Description: Software upgrades are allowed but will be blocked after the upgrade grace period of 90 days expires. Please check show license platform summary/detail for more information.), (Recommended Action: Rectify the upgrade Out of Compliance as soon as possible.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-3-DEV_LIB_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred when loading the PD library for a specific platform's dll for device access, causing the process to return unexpectedly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does IS-IS select the best path to a destination? ### Response: IS-IS follows this route selection: 1) Prefer L1 path over L2 path, 2) Prefer internal path over external path, 3) Prefer lowest metric, 4) Load balance across up to 6 equal-cost paths. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-THREAD_MUTEX_UNLOCK ### Response: (Severity: 7), (Category: OS), (Description: A internal mutex operation has failed. This is a bug.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. show process blocked ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_SERVER-3-ERR_INIT ### Response: (Severity: 3), (Category: L2), (Description: ASIC scan server has failed the initialization sequence due to the specified reason. This would result in the automatic restart of the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-0-MPA_ACT2_I2C_READ ### Response: (Severity: 0), (Category: PLATFORM), (Description: i2c failures during LC Authentication), (Recommended Action: Please copy the error message exactly as it appears on the screen and gather the output of CLIs 'show diag eeprom-info', 'show tech-support ethernet interfaces'. Please ensure that the MPA type, board PID and serial number are not modified. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_DYNREG-3-INSTALL_AP_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered as new attach point data was being swapped out for old data. As a result, the old data is either still activated, or NO data is activated for this attach point. As this point is would be best to restart the policy_repository to try to clear this inconsistency.), (Recommended Action: Restart the policy_repository process to remedy this situation. Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR_ENCAP-3-SYSDB_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The code has hit a sysdb error situation while applying encapsulation config, for which there is no current handling, therefore the system may now be out of sync.), (Recommended Action: Repeat failed configuration command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-CARD_TYPE ### Response: (Severity: 3), (Category: OS), (Description: PlaceD daemon was unable to obtain the card type. Recovery occurs with automatic process restart.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_QOSEA-6-DEBUG_INIT_FAIL ### Response: (Severity: 6), (Category: QOS), (Description: Debug initialization failed within EA. Debugs may not be printed), (Recommended Action: Try restarting QoS EA process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-BOARD_REMOVAL_PWR_OFF ### Response: (Severity: 4), (Category: DRIVER), (Description: When partially disconnect the card from midplane, the SEATED_L pin will deassert indicating the board removal event, but if the card is left in that position, it will continue receiving power and it's CPU will continue to run. To avoid improper seated card from continue to operate, CCC driver will power-off the card.), (Recommended Action: When removing a card from system, make sure that connection to the midplane is disconnected in a clean way.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-7-ERRRATE_EXCEED_DEBUG ### Response: (Severity: 7), (Category: FABRIC), (Description: The fabric driver encountered the annunciated error. The Fabric driver and the System should still continue to function as normal.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-6-HW_PLAT_INIT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the LC hardware in the platform L2FIB component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_PROG_BFD_DISC_TBL ### Response: (Severity: 3), (Category: OS), (Description: The system failed to program BFD discriminator table on the linecard.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-3-RECVFROM ### Response: (Severity: 3), (Category: L2), (Description: The socket call recvfrom returned an error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. A Socket level error, nothing to be done.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-2-RSP_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: LC CPU controller driver detected fabric parity from RSP.), (Recommended Action: If all other LCs also report this parity error alongwith peer RSP, then check for any bent pins on the RSP for which the problem is reported. Reload the RSP that has the problem a few times. If problem persists, contact support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SM-3-CANNOT_DO_DLL ### Response: (Severity: 3), (Category: INSTALL), (Description: The install infrastructure failed to open/close/reopen a DLL), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_PERSIST_REPROG_RESOURCE_THRESH ### Response: (Severity: 1), (Category: PLATFORM), (Description: ASIC errors need to reprogram resource have happened, such errors has crossed threshold.), (Recommended Action: Errors that cause reprogram resource have happened and exceeded threshold. The error condition has been handled.Collect required information and contact TAC *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-SRGB_LIM_EXCEED ### Response: (Severity: 4), (Category: ROUTING), (Description: Platform does not support the configured segment routing global-block range. This may result in failure in label allocation and affect feature working until it is resolved. Separate errors will get reported in the event of such an allocation failure.), (Recommended Action: Change the segment routing global-block configuration to avoid exceeding the platform maximum supported label value.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rlogin-3-ERR_FLUSH ### Response: (Severity: 3), (Category: IP), (Description: tcflush() call failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON-3-ERR_EVENT_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize event manager event.), (Recommended Action: No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE* Else try restarting manually. Get the job id 'show processes afmon_ea location <>' 'process restart location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-3-BANDWIDTH_RANGE ### Response: (Severity: 3), (Category: QOS), (Description: The minimum bandwidth or shape rate configured is out of the supported bandwidth range at this level. The message will provide further details on the error.), (Recommended Action: Please adjust the bandwidth parameters in the policy map.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_MISSFILENAME ### Response: (Severity: 4), (Category: SYSDB), (Description: The command entered requires an file name and one was not supplied.), (Recommended Action: Use the help command to determine the correct usage for this command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR backup bandwidth protection feature? ### Response: The MPLS TE FRR backup bandwidth protection feature extends the bandwidth protection concept to backup tunnels. It ensures that backup tunnels configured for bandwidth protection have a bandwidth guarantee and do not use bandwidth needed for primary tunnels. This avoids oversubscription on the backup path and ensures that FRR can always redirect traffic successfully. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-RX_ALARM_RAI_SYNC_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: The BITS receiver has detected RAI defect for incoming signal. Receiving remote alarm indication(RAI) means the far-end equipment over the T1/E1 line has a problem with the signal it is receiving from the upstream equipment.), (Recommended Action: Verify input BITS clock signal is set up correctly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-RCC_LIB_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver cannot initialize the RCC memory controller library. The node may be not be able to initialized properly.), (Recommended Action: Collect all the event logs and 'sh controller fabric trace driver all location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-PULSE_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that an IPC failure has occured in Shelf Manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_SHIM-6-LINK_STATE_CHANGE ### Response: (Severity: 6), (Category: PLATFORM), (Description: Spanning Tree Port's state change indication.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-3-MMAP_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: mmap has failed, this may be a program level error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-TIMER_FAILED ### Response: (Severity: 4), (Category: L2), (Description: A Frequency Synchronization process has failed to process a timer event.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-BUF_TOO_SHORT ### Response: (Severity: 3), (Category: ROUTING), (Description: Whilst trying to format a string, the buffer passed in was too short and the string was truncated.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATE_OUT_OF_SYNC-6-UNSUPPORTED_METRIC_ON_BUNDLE_MEMBER ### Response: (Severity: 6), (Category: PLATFORM), (Description: Some metric types of performance traffic monitoring are not supported on a few types of linecards. User added a new bundle-ethernet member that belongs to a linecard with limitation. As a result, performance traffic monitoring on the bundle-ethernet interface will have limitation on that specific member port. Existing member ports will receive the same metric coverage of performance traffic monitoring. Also, the new bundle member will not be fully activated and overall bundle state will remain out of sync.), (Recommended Action: To restore bundle state to in-sync, the new member should be removed. Otherwise, no action is required. This is informational message to remind user of the fact that new bundle member added by the user resides on the linecard which does not support the metric types configured on the bundle parent interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPA_8P_GE-2-SPA_JKT_ERR ### Response: (Severity: 2), (Category: L2), (Description: The Jacket failed to parse spa driver arguments.), (Recommended Action: Check if Jacket process is blocked on any thing. collect the trace log via 'show plim ether trace error location <>' 'show plim ether trace info location <>' 'show tech-support ethernet ' 'show plim jacket trace all location <>' 'sh hw-module trace infra level detailed location' 'sh hw-module trace infra level error location' 'sh hw-module trace infra level summary location' and collect console logs and send them to the Engineering team.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-NOVMEM ### Response: (Severity: 3), (Category: OS), (Description: Not enough memory available for shared memory window in the system. Top shared memory window users will be display on the console.), (Recommended Action: If this message recurs, copy the system message exactly as it appears on the console or in the system log. Collect the following information and contact your Cisco technical support representative. Provide the representative with the gathered information. - show logging - show memory location 0/x/CPUx) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TIMER-3-TIMERNEG ### Response: (Severity: 3), (Category: OS), (Description: An internal error occured in timer api.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_PEM_NO_INPUT ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when one of the power cable to power module is unplugged/plugged in on satellite.), (Recommended Action: Please check Power input connections to the satellite.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-3-VIN_LOW_LEVEL_MINOR_ALARM ### Response: (Severity: 3), (Category: PLATFORM), (Description: 'Input voltage level is too low for this module, it crossed the minor alarm threshold'), (Recommended Action: 'Check/Charge the batteries.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-3-LAS_P_INIT ### Response: (Severity: 3), (Category: IP), (Description: Failed to initialize as producer of the Local Address Service Database), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_IP_EA-3-ERR_INFO_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IP EA. Typically, this is an error where the software fails due to failure during forwarding feature programming. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv4 show cef ipv4 location <> show cef ipv4 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-DEV_CPAK_COMPLIANCE_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A compliance error was detected during CPAK initialization. A compliance error is due to checksum error, EEPROM CRC error, vendor data error, or decryption error. The CPAK is the pluggable optics on the line cards. CPAK initialization may happen when linecard boots up, CPAK OIR and line card process restart. The optics will not be enabled if an CPAK compliance error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show system verify' command in Cisco IOS XR? ### Response: The 'show system verify' command in Cisco IOS XR is used to verify the consistency and integrity of the system configuration and software packages. It checks for any missing or corrupted files, inconsistencies in the configuration, and other system-level issues. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SECGN-3-PD_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error occured while processing messages from PI or in allocating memory.), (Recommended Action: Collect the following logs. 'show logging', 'show tech-support services cgn location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZPLL_API-7-ERR_INIT ### Response: (Severity: 7), (Category: PLATFORM), (Description: Zarlink client Api initilization failed.), (Recommended Action: Failure action and reason is part of error message. The process will be restarted in sometime. But if error is seen with every restart then contact TAC with show tech-support frequency sync) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR-3-CLEAR_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Procmgr clear has failed due to sysdb error.), (Recommended Action: Contact support with required information) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-ERR_INIT_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in FIB MPLS. Typically, this is an error where the software fails during initialization. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid during initialization. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware during initialization/ configuration. - Resource limitations. This condition indicates a problem where the software has limited resources to operate on.), (Recommended Action: Please collect the console log and the CLI output. show cef show memory summary show cef location <> show memory location <> show cef trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_CLIENT-7-SENSOR_NOT_FOUND ### Response: (Severity: 7), (Category: OS), (Description: No sensor found), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SP_NOT_ZERO_1_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Non-zero seg profile detected on xaui-1 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-LWM ### Response: (Severity: 3), (Category: ROUTING), (Description: A call to an external light-weight messaging function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospf - show ospf trace all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-SHMEM ### Response: (Severity: 3), (Category: PLATFORM), (Description: Shared memory errors during improper updation of variables or incorrect return state in MPLS FIB platform), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FILECOPY_LIB-3-BAGDECODE ### Response: (Severity: 3), (Category: OS), (Description: An attempt to decode a filecopy bag failed. This may be due to like low memory. You may need to free some resources from other processes if the system is running low on memory - if freeing up resources does not fix the problem, please contact your customer support representative and file a bug against the infra-filecopy-srv component.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-CANT_GET_FILES ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the infrastructure is behaving incorrectly. The Package infrastructure could not get a required the list of files that this package contains, so processing of the current operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-6-GOT_CISCO_VSA ### Response: (Severity: 6), (Category: SECURITY), (Description: An internal software error has occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_SYSDB_DELETE ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-IDT_TIMER_FIRED ### Response: (Severity: 4), (Category: L2), (Description: The specified PTP process has not received all its checkpoint IDTs and so is continuing its initialization without loading all of its checkpointed information.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_OUT_MEM_CORR_ECC_ERROR_LNK4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast output memory correctable ECC error on link 4), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-FSM_LEAF_TIMER_CREATE_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that Shelf Manager has failed to create a timer that is intended to check a nodes boot progress.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-4-TRACE ### Response: (Severity: 4), (Category: MGBL), (Description: This is a non-fatal error and can happen when router is low on memory. It should not affect the functioning of the router, but trace messages may not be logged.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-6-NETIO_UP ### Response: (Severity: 6), (Category: OS), (Description: Pre-IFIB process established connection to NetIO.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-3-FWC_SPU_CLEAR_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: The Firewall Controller's attempt to set an invalid entry in the SPU context table following a firewall delete has failed. This will have left the system in an inconsistent state.), (Recommended Action: Restart the Firewall Controller process using the 'process restart' mechanism.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPMC_GTRIE_DEFAULT-3-INIT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Error while initializing Gtrie. Initialization failed and aborted), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_VCM-3-IM_OP ### Response: (Severity: 3), (Category: L2), (Description: The operation on the named item is not completing successfully when it is expected to, and hence the FR support may be disabled. The operation could be one of the following: - [en/de]capsulation remove - caps remove/add - caps base define), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_LMI-3-FSM_T391_EXPIRY ### Response: (Severity: 3), (Category: L2), (Description: This indicates that Frame Relay Local Management Interface's Finite State Machine has gone into an error condition. We should not have a valid t391 timer expiry event if the FSM for this particular interface was in STOPPED state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-LPTS_DELETE_BINDING ### Response: (Severity: 3), (Category: ROUTING), (Description: The clns process was unable to delete a binding from LPTS. This is an internal error.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-1-FATAL_ERR ### Response: (Severity: 1), (Category: FABRIC), (Description: --), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-MEMORY_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to allocate memory.This error condition indicates a problem with the memory allocation.), (Recommended Action: Please collect the console log and the CLI output. Copy the error message exactly as it appears on the console or in the system log. Issue the cmd command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the cmd output, call your Cisco technical support representative and provide the representative with the gathered information. show cef show cef location <> show cef trace location <> show cef platform trace common all location <> show cef platform services resource oor common loc show cef platform services resource shm-objects common loc show cef platform services trace common all reverse loc show cef platform services trace common errors reverse show cef platform services trace common all reverse loc Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information. show cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-ASIC_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: The asic initialization failed due to the above mentioned error.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-SYSDB ### Response: (Severity: 3), (Category: OS), (Description: A call to a sysdb interface failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-4-CAT_ERROR_CRIT_INFO ### Response: (Severity: 4), (Category: PLATFORM), (Description: The message indicates for ZENGL FPGA catastrophic/fatal event. Node will be brought down on second occurence of such event within default period of three months as per expected software recovery.), (Recommended Action: Once shutdown proceed with unit/board RMA to avoid any probable severe impact on the system as a whole. Please note one can do physical OIR of the Unit/Board to to recover, though its not recomended. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-ENS_REGISTER_CLASS ### Response: (Severity: 7), (Category: OS), (Description: RDS library uses ENS/GSP services to read/write data. While using ens API to bulk register, it returned failure. ens_bulk_register failed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-BAD_CORE_SIZE ### Response: (Severity: 7), (Category: OS), (Description: Dumper calculates the size of core file based on the segment size of the process before dumping the core. If dumper fails to fetch some data of the process due to devctl or anyother reason,the core file will be incomplete.This will impact the core file. It will not impact the traffic or system behavior.), (Recommended Action: Please ensure of enough space is present on the configured device (df -kh . will give you the space statistics of the current disk). If space is less, please remove previous core files. If the issue is still seen, please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. follow process 6. If possible please collect debug messages of dumper.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZEN-3-BACKUP_FPD_LOADED ### Response: (Severity: 3), (Category: INFRA), (Description: The output of 'show hw-module fpd' will show the affected image with BACK IMG state. This can happens when ZEN detects that Primary image is corrupted, so it fallback to load the backup image to recover from the failure.), (Recommended Action: Although the system will continue to run, the backup image might be of older version and it might have known issues that have been fixed on latest version. So it is critical to address the problem as soon as possible. To correct the problem, use the 'upgrade hw-module location fpd ' command to re-program the FPD image and power-cycle the affected card for ZEN to load with the upgraded image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM_CAP-1-CFM_RESTART_REQUIRED ### Response: (Severity: 1), (Category: PLATFORM), (Description: There has been a change (toggle) in 'bundle-offload' configuration. Process restart of cfm is required on active RSP for the changes to take effect.), (Recommended Action: Execute the following command on the console to restart the cfm process: 'process restart cfmd location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM_COMMON-3-BAD_CHECKSUM ### Response: (Severity: 3), (Category: MEDIA), (Description: nvram corrupt.), (Recommended Action: If need to use classic configs, boot an appropriate classic image and rewrite the config. If not No action is required..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-2-BLG_RDY_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Interrupt controller driver detected a fab arbiter ready error (ack not received).), (Recommended Action: Please correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-3-NO_VFW ### Response: (Severity: 3), (Category: SERVICES), (Description: RSPP MA, the service diversion management agent, could not complete initialization as the firewall service package could not be found in the current installed image. Restart will not be attempted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POS-4-NOT_SUPP ### Response: (Severity: 4), (Category: L2), (Description: The specified configuration is not supported by the dataplane.), (Recommended Action: If any problems are seen, they may be rectified by removing the unsupported configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_EVM_SEND ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA failed to send the specified message. The cause may be a resource starvation problem but is most likely to be an internal programming error. The error message should give more details.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart the affected PPPoE MA process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSA-3-ERR_GSP_GROUP_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric statistics aggregator process encountered an error to create group for GSP communication. This software error will cause process termination to recover. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_IO-7-ERR_PAK ### Response: (Severity: 7), (Category: ROUTING), (Description: Some error occurred in Packet (IP/MPLS/ICMP) related operations. The text of the message displays the failed operation and the related error code. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_4_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LAMPTEST-6-ABORTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: Lamp Test has been aborted due to an internal error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROL_DRIVER-0-COULD_NOT_AUTHENTICATE_HW ### Response: (Severity: 0), (Category: DRIVER), (Description: Card manager has failed to authenticate for Cisco HW genuine check This could happen in 2 cases - Secured Local card IDPROM read failed and authentication is not possible - There ACT2 Chip Acess(bus access problem) or Secured Certificate Errors), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNVGEN-3-ERR_THREAD_MUTEX_LOCK ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to pthread_mutex_lock() was unsuccessful'), (Recommended Action: Collect the following logs and contact your technical support representative for assistance. a) Console messages b) show tech-support parser c) follow process nvgen_server d) show proces blocked e) follow process ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-3-SKT_ECTW_RD_PERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-3-CALLOC_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: --), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT-2-ILK_IF_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Punt interlaken interface has failed.), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. Please verify that the FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MVRP-4-PROBLEM_EXITING ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during shutdown of the MVRP process, and it was unable to notify the System Manager that it was about to exit. In rare cases, this could result in a failure by the System Manager to restart the process when it ought to do so.), (Recommended Action: If the process ought to be running and is not, then attempt to restart it using the 'process restart' command. If this fails, deconfigure the process and re-enter the configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-RESTART_DUE_TO_INSTALL ### Response: (Severity: 6), (Category: INFRA), (Description: The process restarted due to an install operation. This is expected behavior), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNVGEN-3-CIDR_API_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: Failure in check_cidr_knob API, input parameter is a NULL pointer'), (Recommended Action: Collect the following logs and contact your technical support representative for assistance. a) Console messages b) show tech-support parser) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_PFI-3-NPU_INST_CREATE_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Platform PFI was unable to create npu id instance. The returned error code should indicate the reason for the failure of the api. This is a transient error in the system likely due to some config events. The client logging this error should retry the api and/or handle this error accordingly. If this error is seen persistently, Initiate the recommended action.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-TX_ALARM_TAF_SYNC_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Condition raised possibly due to incorrect internal BITS transmitter configuration.), (Recommended Action: Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-RACK_NOT_BOOTED_UP ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that there is no rack serial ID to rack number mapping configuration and a rack is trying to boot.), (Recommended Action: In admin configuration mode, please configure rack serial number to rack number mapping using the below command: dsc serial rack ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_LQ_FULL_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue full error on XAUI 0 LQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC15 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-3-FWC_FWS_FW_NOTFOUND ### Response: (Severity: 3), (Category: SECURITY), (Description: The Firewall Controller has been told to update firewall information as a result of a firewall state change but has been unable to find the firewall in the firewall database. This indicates that the system is in an inconsistent state.), (Recommended Action: Restart the Firewall Controller process using the 'process restart' mechanism, the firewall controller should resynchronise) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_UPD-3-BACKUP_FPGA_LOADED ### Response: (Severity: 3), (Category: INFRA), (Description: The Backup images has been loaded on the indicated card. This can happen when process detects that the Primary image is corrupted, and the HW fallbacks to load the backup image to recover from the failure.), (Recommended Action: Although the system will continue to run, the backup image set might be of older version and it might have known issues that have been fixed on latest version. So it is critical to address the problem as soon as possible. The output of 'show hw-module location fpd' will identify the image with the problem with NEED UPGD state and it will have missing Programmed version. To correct the problem, use the 'upgrade hw-module location fpd ' command to re-program the FPD image and power-cycle the affected card for FPGA to load with the upgraded image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: action-3-PEG2MSG ### Response: (Severity: 3), (Category: OS), (Description: This is a test message for action->peg message), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABMGR-2-FABRIC_LINK_DOWN_FAULT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric link is down.), (Recommended Action: Fabric link is down. Recovery action would be taken. If the error is persistent, contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-TX_OVF_ERR_FIA10 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA10 Tx overflow error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you configure IPFIX in Cisco IOS XR? ### Response: To configure IPFIX in Cisco IOS XR, use the 'flow exporter-map' command to define the export parameters such as the destination IP address and port, source interface, and version (IPFIX or NetFlow v9). Then, use the 'flow monitor-map' command to define the monitor parameters such as the record format and exporter. Finally, apply the monitor to the desired interfaces using the 'flow' command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-ACTIVATION_STATE ### Response: (Severity: 3), (Category: OS), (Description: The activation state of the named virtual service has changed as notified by Virt-manager.), (Recommended Action: In the failed case, check Virt-manager's logs for the cause of the failure. In the successful case, this notification can be ignored.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_0_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-NODE_CREATION_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: Error in getting rack/slot/module numbers from system database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_4_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IEP-3-DAEMON_ERR_SYSDB_BIND ### Response: (Severity: 3), (Category: IP), (Description: An error occurred while using SysDB.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-DEV_CPAK_PID_NOT_SUPPORTED ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PID not supported error was detected during CPAK initialization. A PID not support error is reported when either the PID can not be read it not supported on the platform. The CPAK is the pluggable optics on the line cards. CPAK initialization may happen when linecard boots up, CPAK OIR and line card process restart. Traffic will not be impacted by this error.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the Cisco IOS XR Diagnostics feature in troubleshooting? ### Response: The Cisco IOS XR Diagnostics feature provides a set of diagnostic tools and tests that can be used to troubleshoot hardware and software issues. It includes tests for the CPU, memory, disk, network interfaces, and other components, as well as tools for collecting and analyzing system logs and dumps. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_12IN1-1-CLOCKRATE ### Response: (Severity: 1), (Category: L2), (Description: The DTE received clock rate has changed from below the threshold configured to above or vice versa.), (Recommended Action: Check the received clock rate from the provider end and the clockrate threshold configuration. If the clock rate goes below the threshold configured, the interface is brought down.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_SSE-3-ERR_LTRACE ### Response: (Severity: 3), (Category: L2), (Description: BFD SSE was unable to initialize the tracing services. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective MSC reboot.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHDLC_EA-4-ERR_EVM_EVENT_BLOCK ### Response: (Severity: 4), (Category: L2), (Description: An error occured in the event loop. The process will restart which should recover the situation.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_MPLS_EA-3-ERR_MEM_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in MPLS EA. Typically, this is an error where the memory allocation / access fails. Here is a list of possible reasons for this message (not all-inclusive). 1) Memory exhaustion due to overall system load 2) Shared memory access failure 3) Memory leaks leading to resource exhaustion), (Recommended Action: Please collect the console log and the CLI output. show cef show memory summary show cef location <> show cef mpls trace location <> show cef platform trace all all location <> show memory location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WATCHDOG-3-ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: This message indicates that a failure has occured in Watchdog), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-OPERATION_ABORT ### Response: (Severity: 3), (Category: INSTALL), (Description: Specified install operation in the error message aborted.), (Recommended Action: The reason for this install operation failure has to be analyzed. Check the install operation log by 'show install log ' id is same as displayed in the syslog message which will be helpful to understand the reason for the install operation failure. Collect the show tech logs by running 'show tech-support install' and forward the logs to the TAC. Collect the install operation logs by running 'show tech-support install' on admin as well. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-2-INVALID_PLANE_SHUT_REQ ### Response: (Severity: 2), (Category: FABRIC), (Description: This indicates that fsdb aserver process has received the request to shut down a fault plane. The plane is not shut down by the fsdb aserver due to the reason mentioned.), (Recommended Action: If the identified plane is not already shut, shut down the plane in admin configuration: controller fabric plane <> shutdown Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_TOPAZ-7-ERR_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered the specified error during the initialization sequence. This facility is deemed crucial and hence the process is automatically restarted on this failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-2-VID ### Response: (Severity: 2), (Category: L2), (Description: The VID information is displayed for both supported and unsupported sfp/xfp types for the following actions - OIR of SFP/XFP - Soft and Hard OIR of SPA/LC - unshut of SPA - Enabling power for LC), (Recommended Action: No actions are required as this is just an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-7-RAM_DETAILS ### Response: (Severity: 7), (Category: PLATFORM), (Description: Details about the ECC error happenned before.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-SOCKET_COMMUNICATION_FAILURE ### Response: (Severity: 4), (Category: DRIVER), (Description: CCC Driver have encountered a fatal socket error. This will lead to ethernet down from the RP/SC on which the syslog is encountered. Recreation of sockets will be tried to recover it.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-5-ID_MGR_OOR ### Response: (Severity: 5), (Category: L2), (Description: L2VPN ID Mgr keeps track of IDs for different features. If a feature runs out of IDs, new instances cannot be provisioned.), (Recommended Action: Remove unused configuration to free up IDs in the system. Resource limits can be seen using 'show l2vpn capability'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the function of the 'install diff' command in Cisco IOS XR? ### Response: The 'install diff' command in Cisco IOS XR compares the currently active software packages with those in a specified repository or package file, highlighting differences. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISLM-4-ACCOUNTING_SUBLABEL_MISMATCH ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This syslog is printed when Sub-Lable mismatch between Subcriber Context and FADB.), (Recommended Action: Collect Show tech and generated running core files.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-5-TABLE_ROUTE_RATE_GLACIAL ### Response: (Severity: 5), (Category: ROUTING), (Description: Error while enabling/disabling per route rate in a table), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_SENSOR_VOLT_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: The sensor in the satellite module reported a critical hi/lo sensor value against the configured threshold value.), (Recommended Action: Verify current sensor temperature values using the CLI: Copy the error message exactly as it appears on the console or in the system log. Issue the (admin)# show env command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin)# show env output, call your Cisco technical support representative and provide the representative with the gathered information. --> particularly for temp output of SAT ID. Copy the error message exactly as it appears on the console or in the system log. Issue the (admin)# show env trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin)# show env trace output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR_ENCAP-3-INIT_SYSDB_BIND_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Process failed to bind to SysDB while applying encapsulation config. This could be due to invalid arguments, invalid path or an internal error for which there is no current handling, therefore the system may now be out of sync.), (Recommended Action: Repeat failed configuration command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-DEBUG_RETRIES_EXCEEDED ### Response: (Severity: 3), (Category: ROUTING), (Description: CLNS tried to initialize packet debugging functions but was unable to succeed even after a number of attempts. No more attempts will be made.), (Recommended Action: Please contact the cisco-support in case this error re-occur. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel primary feature? ### Response: The MPLS TE auto-tunnel primary feature enables the automatic creation of primary MPLS TE tunnels between tunnel head-end and tail-end routers. It simplifies the provisioning of TE tunnels by automatically creating them based on a template configuration. Auto-tunnels are created to next-hop routers learned via IGP. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-3-SYSMGR_PROC_READY_FAILED ### Response: (Severity: 3), (Category: L2), (Description: Indicating to sysmgr that the process is not ready %s - Process name %s - error/warning condition), (Recommended Action: Try for process restart If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-7-UNEXPECTED ### Response: (Severity: 7), (Category: OS), (Description: An unexpected condition encountered. This is not necessarily an error.), (Recommended Action: Collect system log information. Collect show tech ssm. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_400G_POD-3-LOW_2_5VCC ### Response: (Severity: 3), (Category: FABRIC), (Description: The POD detects a low in 2.5Vcc voltage. The POD might not be functioning properly, and can cause cell drops or corruption in the rx or tx link associated with the POD.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-3-ERR_USAGE ### Response: (Severity: 3), (Category: FABRIC), (Description: Incorrect command line parameters were passed to the FGID Server, and so it failed to start.), (Recommended Action: Check the startup arguments passed to FGID-DB. A default configuration will be used if no parameters are passed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-EVM_INIT_EVENT ### Response: (Severity: 3), (Category: HA), (Description: An internal error was detected when trying to initialize a sigevent structure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-5-USER_PASSWD_LOCKED ### Response: (Severity: 5), (Category: SECURITY), (Description: The user is temporarily locked out for exceeding maximum unsuccessful logins. The user gets unlocked automatically after the lock out time is expired.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2TP-3-DIFF_L2TP_CLASS ### Response: (Severity: 3), (Category: L2), (Description: A new session maps to an existing L2TP tunnel, but the session references a L2TP class different than what this tunnel is using.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_RADIUS_OVRRID_PORT_LIMIT_RCH ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions on a particular Circuit ID and Remote ID has reached the maximum which has been supplied via RADIUS.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_QFPCPUCTRL-1-DEV_ID_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Unexpected CPU controller device ID.), (Recommended Action: Replace board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COREHELPER-3-MALLOC_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Failed to allocate memory when copying the context file.), (Recommended Action: show memory, show media, collect console logs. Report this message to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_3_LOW_TEMP_ALARM ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser temperature less than or equal to the low temperature alarm threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the QSFP+ with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSHD-2-ILLEGAL_PORT ### Response: (Severity: 2), (Category: IP), (Description: The connection between rsh client and server must from/to a privileged port (512-1023)), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is an SMU in the context of IOS XR? ### Response: In the context of IOS XR, an SMU (Software Maintenance Upgrade) is a software 'patch' delivery unit that, after being installed and activated, provides a 'point-fix' for a critical issue in a given software release. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_LA_QOS-2-VOQ_REACTIVATION_FAILED ### Response: (Severity: 2), (Category: QOS), (Description: VOQ restore to ACTIVE from DROP failed at ingress when watchdog event is cleared at egress device.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLU-4-CONFIG_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: config will be activated only after a line card reset), (Recommended Action: config will be activated only after a line card reset. Reboot the LC during the next maintenance window.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the two primary security functions of a router in Cisco IOS XR? ### Response: The two primary security functions are: 1) To protect customer and service provider infrastructure by supporting network security features such as unicast reverse path forwarding (uRPF), access control list (ACL)–based filtering, and prefix filtering. 2) To protect the router from malicious or unintended security attacks and intrusions. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-NULLARG ### Response: (Severity: 3), (Category: OS), (Description: Invalid arguments are passed to the function.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_MAP-3-MALLOC_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A call to malloc() failed while adding the RPs in the range list.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show processes autorp_map_agent detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes autorp_map_agent detail output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show memory summary command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show memory summary output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp mapping-agent trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp mapping-agent trace output, call your Cisco technical support representative and provide the representative with the gathered information. Using the Job ID from the above commands, run the following to see if the memory is not exceeding. Copy the error message exactly as it appears on the console or in the system log. Issue the show processes memory command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes memory output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-3-INVMGR_MAX_SLICE_NUMBER_MISMATCH ### Response: (Severity: 3), (Category: L2), (Description: The NPU driver received max slice number diff than existing value), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_DUS ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from DUS. The signal is often manually changed to or from DUS to prevent timing loops from occurring. Sending a DUS prevents the timing from being reused in a loop. The DUS signal can also be sent for line maintenance testing.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-LTRACE_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: The ltrace buffer could not be initialised), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different IS-IS router types and what level adjacencies do they form? ### Response: The IS-IS router types are: L1 router (forms L1 adjacencies), L2 router (forms L2 adjacencies), and L1/L2 router (forms both L1 and L2 adjacencies). Two L1/L2 routers will form both L1 and L2 adjacencies if their area IDs match, or only an L2 adjacency if their area IDs differ. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN-3-WIN_MUTEXOP_FAILED ### Response: (Severity: 3), (Category: OS), (Description: SHMWIN encountered an error condition, a mutex operation failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture - show logging - show shmwin trace all location 0/x/CPUx - dumpcore running location 0/x/CPUx) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-3-WRONG_COMP_MAGIC_NUMBER ### Response: (Severity: 3), (Category: OS), (Description: Core dump file compression header is broken. This will result in a truncated core file.), (Recommended Action: Please validate if the process exists or not. Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ORA-4-MERGE_FAILED ### Response: (Severity: 4), (Category: ROUTING), (Description: One or more base types were not available when bringing together the parts of this attach point. This is an item that should be caught during testing. If it does show up, support should be contacted.), (Recommended Action: Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-3-UNK_RECOVERY_ACTION ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform Fault Manager Node detects an invalid Reset action defined in the Application Fault Condition Database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-NBR_NSR_DISABLED ### Response: (Severity: 3), (Category: ROUTING), (Description: NSR has been temporarily disabled on the neighbor due to transport issues.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp confederation identifier' command in IOS XR BGP configuration? ### Response: The 'bgp confederation identifier' command is used to configure the BGP confederation identifier. A confederation is a technique used to reduce the iBGP mesh inside an AS. The AS is divided into multiple sub-AS, each identified by a confederation identifier. Each sub-AS has a full iBGP mesh, and an eBGP session is used between the sub-AS. To external peers, the confederation still appears as a single AS. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_LCP-4-L2_NOT_SUPPORTED ### Response: (Severity: 4), (Category: L2), (Description: L2transport has been configured on an interface that does not support it. The interface will not enter L2 mode, and will remain in whichever mode it was in before. This will occur if the interface capabilities do not support L2 mode, or if L2 mode is configured on a multilink bundle member.), (Recommended Action: Reconfigure the interface so that l2transport is not enabled.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-6-WDG_BARRIER_STALLED ### Response: (Severity: 6), (Category: FABRIC), (Description: Ingressq, Barrier stalled on one of the casts), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-2-CRIT ### Response: (Severity: 2), (Category: PKT_INFRA), (Description: A critical error has been detected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_0_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser bias greater than or equal to the high laser bias alarm threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERG-3-IM_OPER_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: An interface manager related operation was unsuccessful, leaving the interface in mostly inconsistent state with respect to Session Redundancy. The exact reason for the failure need to be analysed based on the error string being printed. The batch operation could be to register/deregister for an interface state or add/remove of interface capsulation or update of Session Redundancy attribute to IM. The operation has been retried for the specified number of times before quitting.), (Recommended Action: The error is mostly a software problem in Session Redundancy module or the Interface Mananger module - If interface un-registration fails, then it would not have a functionality impact on the software. It could mostly happen when interface config is removed from Session Redundancy or Session redundancy config is itself removed. If the config is added back the system is expected to continue to work without any further problems. - For capsulation remove error, check all Session Redundancy client have been notified of the removal. For Ex: if DHCPv6 is the client, then check the dhcp v6 proxy/server interface state for SERG role. If capsulation removal is notified, then it would not have functionality impact as in the un-registration case. Else troubleshooting is required. - For all other errors trouble shooting is required. Workaround: restart serg_agt/serg_mgr process (whichever process caused error)) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the common thread states in the IOS XR microkernel? ### Response: The common thread states are\n- Running: Thread is currently executing on CPU\n- Ready: Thread is ready to execute, waiting to be scheduled\n- Blocked: Thread is waiting for an event (message, I/O, timer)\n- Receive blocked: Waiting for a message\n- Reply blocked: Waiting to reply to a message\n- Interrupt blocked: Waiting for an interrupt\n- Mutex blocked: Waiting for a mutex\n- Stopped: Thread is suspended and will not be scheduled\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-IDB_VERIFY1_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp global-interface command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp global-interface output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp interface command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp interface output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace im error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace im error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-7-INIT_FAIL ### Response: (Severity: 7), (Category: ROUTING), (Description: An error occurred during initialization, causing the process to terminate.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-LINK_WRONG_RESULT ### Response: (Severity: 3), (Category: OS), (Description: This is a debug message that is not compiled into a customer version of the code.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-CF_OVF_ERR_FIA11 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA11 channel FIFO overflow error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_PFILTER_EA-3-ERR_APPLY_ACE_MOD ### Response: (Severity: 3), (Category: ACL), (Description: 1) An ACE modification can fail in apply/commit phase because of one of the following reasons: a) TCAM max limit has been reached.), (Recommended Action: 1) When this error occurs the running-config will not be in sync with line card ACL hardware programming. 2) If the ACL could not be removed from hardware a line card reload is recommended.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-ERR_HW_THRESHOLD_SHUTDOWN_PORT ### Response: (Severity: 3), (Category: L2), (Description: A hardware error is detected on the PLIM, and the error threshold has been crossed. Software will take action as described in the error message to try to contain or recover from the error. The hardware error and the software recovery action will cause shutting down the port. Device: %s%s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Threshold of %s - the defined threshold for this error. Software action: %s - the action that software will take to try to contain or recover from the error. Recommended user action: %s - recommended action to the user. Possible values: 'none' 'replace XFP' 'PLEASE MANUAULLY RELOAD THE LC AT NEXT MAINTENANCE WINDOW'), (Recommended Action: Take the recommended user action as it is described in the error message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAIPC_NETIO-7-PAK_INPUT_FAIL ### Response: (Severity: 7), (Category: OS), (Description: netio_dll_packet_input_NEW() to Qnet failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2SNOOP-3-RED_INIT ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the L2SNOOP process try to do redundancy related init with System Manager for the node state changes.), (Recommended Action: The process will attempt to recover from this situation by restarting or retrying. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-6-IFIB_RES_SET_FAILED ### Response: (Severity: 6), (Category: OS), (Description: Failed to set platform-secific IFIB results.), (Recommended Action: Please provide the output of following commands: - show tech-support lpts - show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-3-ERR ### Response: (Severity: 3), (Category: OS), (Description: An ERROR level message was emitted by QNET.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-MEMORY ### Response: (Severity: 3), (Category: SECURITY), (Description: locald failed to allocate the required amount of memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-EVENT_FILE_ATTACH_FAILED ### Response: (Severity: 3), (Category: OS), (Description: 'Failure in event file attach.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-0-BARRIER_STALL_ROUTER_RELOAD ### Response: (Severity: 0), (Category: FABRIC), (Description: Router is brought down if RPs on the dsc rack are detected stalling on fabric barriers. If the dsc rack is isolated from fabric via CLI, then this is expected. If this message occurs otherwise, it could be due to a software error or an unexpeced hw error.), (Recommended Action: If fabric links, fabric cards or fabric chassis connecting to the dsc rack are brought down via CLI, then this is expected. If the problem happens otherwise, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-6-ERR_EVC_DESTROY ### Response: (Severity: 6), (Category: L2), (Description: During process termination PPP MA failed to destroy a connection to a service provided by another process. This is an internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_0_XAUI_PLL_LOCK_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: NPU-0 XAUI PLL not locked on bridge instance-3.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPMC_GTRIE_DEFAULT-4-WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error. A significant event but we can still continue), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-3-UNALLOCATED_QUEUE_NOT_EMPTY ### Response: (Severity: 3), (Category: L2), (Description: Egressq driver detected that packets were sent to an Egressq queue which is unallocated. These packets will not be serviced and will remain in the queue until this queue is allocated and becomes active. This situation should normally not happen, but may possibly happen during transient conditions when egress queue information is being updated (for e.g. on SPA OIR). During this brief time period, one or few packets may be sent to an incorrect queue.), (Recommended Action: If this message appears more than once in response to the specific action taken or if the message indicates a large number of bytes (more than 10MB) in an unallocated queue(s), Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-IDB_ADD_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace im error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace im error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-4-PULSEQ_ALARM ### Response: (Severity: 4), (Category: HA), (Description: PulseQ state on this node is below the Severe/Critical threshold.), (Recommended Action: The top 5 pulseq user processes will be dumped to screen. If the state goes to critical state kill the top process/processes in the dumped list.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIAAPI-4-INVALID_PARM_REDFS_ERROR ### Response: (Severity: 4), (Category: MEDIA), (Description: Redundancy FS got an invalid parameter value when RedFS was trying to recover from storage media issue), (Recommended Action: Report this message to TAC. Capture console log, 'show media', 'show mirror statistic' and 'show mirror trace' for TAC and ddts.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-6-CONFIG_CHG ### Response: (Severity: 6), (Category: ROUTING), (Description: This configuration is obsolete; It will be removed from a future release.), (Recommended Action: Remove the configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD_NETIO_TOPAZ_DLL-3-PAK_PROC_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: There was an packet processing error. Possible causes 1) Unable to retrieve fabric dest addr from inside the pkt 2) Error setting/getting input ifh from pkt), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_BURNER-3-BAD_ARG ### Response: (Severity: 3), (Category: PLATFORM), (Description: Bad coammand option.), (Recommended Action: No action is required..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSA-3-PROV_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Provisioning of specified slice has failed), (Recommended Action: The casue for the provisioning failure has to be analyzed. Collect the show tech logs by running 'show tech-support ' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-6-UNEXPECTED_OPERATION ### Response: (Severity: 6), (Category: IP), (Description: A client has performed an unexpected operation on an XR socket.), (Recommended Action: The information in required_info to be collected and engineering team to be notified. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_NPH_LEN_0_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Invalid egress NPH length detected on xaui-0 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-SPA_CREATE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cctl_spa_server process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process cctl_spa_server location <>' to verify that the process is up and running.If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_FI_INTR_RCTL1_HI_OVERRUN_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_FI_INTR_RCTL1_HI_OVERRUN interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-LSP_RECORDROUTE ### Response: (Severity: 5), (Category: ROUTING), (Description: The specified interface record-route has changed.), (Recommended Action: None. This is a solicited message (by 'logging event lsp-status record-route' \ interface destination configuration) and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSVDPMEM-3-BAD_DATAFILE_VALUES ### Response: (Severity: 3), (Category: OS), (Description: Reserve Physmem encountered a severe error and is not able to recover from the error. Details are provided with the error message. Call support with this error message text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMITH-3-RT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This msg can be an indication of incomplete smith driver initialization or an intermittent failure of HW register reads. It may or may not have functional impact depending on cause of failure.), (Recommended Action: Collect the 'show logging' output.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-AWAIT_FGID_DOWNLOAD ### Response: (Severity: 6), (Category: FABRIC), (Description: This indicates Fabric ASICs are initialized pending the FGID download done notification from FGID server. FSDB will be notified about the ASIC initialization complete state only after the ASICs are initialized and the FGID download is completed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_AHS_LOS_LANE3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-4-PON_EXIT_FAILURE ### Response: (Severity: 4), (Category: DRIVER), (Description: An exception has occurred in IOFPGA power-on interpreter while performing an operation.), (Recommended Action: Collect debug info from 'show tech-support iofpga' command and contact your technical support representative with this information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_MGR-7-ERR_DLL_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: CCSQ driver tried to register for a dll but it encountered an error. The driver might lose some of its functionality.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-SW_ERR ### Response: (Severity: 3), (Category: L2), (Description: The operation is failed due to an internal software error. %d - port number. %s - description of the operation. %s - description of the error.), (Recommended Action: Check if the linecard reported any other errors. May need to restart process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-HB_FAILURE_STATS ### Response: (Severity: 3), (Category: PLATFORM), (Description: SIM heartbeat failed, log heartbeat failure statistic), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-2-SYSTEM_RELOAD ### Response: (Severity: 2), (Category: INFRA), (Description: A user requested apply by reload is about to take place which will result in a reload of the entire system. If the apply by reload operation is successful, atomic software changes will be activated after the system reloads.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of using 'install disk-mirroring' in Cisco IOS XR? ### Response: The 'install disk-mirroring' command in Cisco IOS XR is used to configure disk mirroring for redundancy, ensuring data is copied across multiple disks for fault tolerance. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-HISTGROUP_TOO_LARGE ### Response: (Severity: 3), (Category: OS), (Description: A historical group is too large, or internal parameter might be corrupted. This might be because of a corrupted record or Upgrade of system.), (Recommended Action: The file should be saved to other place for later debugging, and then it should be removed to recover current situation. Please clear the OBFL files, as it might be because of corrupted records. CLI : admin clear logging onboard corrupted-files location If the issue is seen after clearing the files, please collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging 5. show tech-support sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-IO_INITSYNC_FAILED ### Response: (Severity: 5), (Category: ROUTING), (Description: A problem occurred in TCP sync, retry TCP sync.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-OOR_GROUP_RANGE_LIMIT ### Response: (Severity: 3), (Category: ROUTING), (Description: This router has reached the maximum value for the number of group ranges allowed to be received through the given group-to-RP mapping distribution mechanism. This can cause an inconsistancy between routers in the PIM domain as to which RP a group maps. This inconsistancy can cause multicast traffic loss for some or all multicast groups. Steps should be immediately taken to reduce the number of group ranges being distributed by the given mechanism or to configure a higher maximum value.), (Recommended Action: Consider reducing the number of group ranges advertised from some set of the candidate-RPs or consider reducing the number of candidate-RPs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-6-MAC_FLUSH_TIMER ### Response: (Severity: 6), (Category: PLATFORM), (Description: When MACs are being flushed from a bridge, unicasting is disabled (everything floods) for a period of time. This message indicates a problem with re-enabling unicast in the bridge.), (Recommended Action: User needs to check all bridge domains to see if any are in unicast disabled state using the platform show command(s). The user should remove and re-configure those bridge domain(s).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LINK-4-BERTADMINDOWN ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Unable to start BERT because controller in admin down state), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: adminexec-3-SYSDB_REGISTER_NOTIFICATION ### Response: (Severity: 3), (Category: MGBL), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-VM_ERROR_CALL_BACK ### Response: (Severity: 7), (Category: HA), (Description: An error occured in CAPI with VM-Manager.), (Recommended Action: This indicates an issue on CAPI with VM-Manger, Collect show tech HBloss, show tech ctrace, vm-monitor process core.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the BGP AS path attribute? ### Response: The AS path is a well-known mandatory attribute that contains a list of the autonomous system numbers that the route has traversed. Routes with a shorter AS path are preferred. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-EVM_ERR ### Response: (Severity: 3), (Category: L2), (Description: PLIM process encountered a software initialization error. LC will not work due to this error .), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed. There was problem with hardware or software initilization. This problem can be resolved by reloading the LC 'hw-module location <> reload'. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-4-LOST_RACK_ON_SYSTEM_RELOAD ### Response: (Severity: 4), (Category: PLATFORM), (Description: We lost connectivity to a rack while the user initiated system reload is in progress. As the entire system is undergoing a reload, it is expected to see the racks going down.), (Recommended Action: This is a warning message for the user intiated reload. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-3-BUS_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A PCIe bus error has occurred. The message has the device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel primary affinity feature? ### Response: The MPLS TE auto-tunnel primary affinity feature allows auto-tunnel primary tunnels to select or avoid links for the primary path based on configured affinity attributes. This provides more control over the primary path selection compared to the default behavior of using the TE metric. Affinities allow primary paths to be optimized for specific requirements. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-RESUME_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: An unknown error was encountered as the instorch process started up in an idle state. This may be resolved by manually restarting the instorch process. If this error is seen multiple times please collect tech-support.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-SYNC_REQUEST_UNEXPECTED ### Response: (Severity: 7), (Category: OS), (Description: When the single writer mode is set, RDS library allowes to create a ticket. Ticket request failed with unknown error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-4-PASSWD_ALREADY_EXISTS ### Response: (Severity: 4), (Category: SECURITY), (Description: An internal software error has occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP_NSR-3-FO_INITIATED ### Response: (Severity: 3), (Category: IP), (Description: TCP's NSR module is initiating a fail-over to maintain NSR because TCP in active role has failed (either crashed or shut down) and fail-over is currently configured as the recovery action.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-3-ERROR_SYSDB_GET ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_EA_IIR_ADD-3-FAILED ### Response: (Severity: 3), (Category: QOS), (Description: The QoS policy could not be applied on the bundle interface member specified.), (Recommended Action: If there are errors in the policy, remove the qos policy, correct the errors and reattach. If there are no errors in the policy, collect the required information and contact your Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-4-QFP_FAILURE_HA_BIND ### Response: (Severity: 4), (Category: L2), (Description: Failed to bind with the QFP high availability infrastructure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers QFPCPUBridge trace <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers QFPCPUBridge trace <> output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFMMIB-3-NO_DEBUG ### Response: (Severity: 3), (Category: L2), (Description: In the initialization of the DOT1AG/MEF SOAM MIB DLL an error occurred while attempting to register for debugging. Consequently there will be no debug output from this MIB DLL. Retrieval of elements of the MIB should be unaffected, but any issues with MIB retrieval may be hard to diagnose. The error message should point to a more precise reason, possibly indicating an out of resource issue.), (Recommended Action: The user may continue to work without access to DOT1AG/MEF SOAM MIB debug, elements of the MIB will still be accessible & elements of other MIBs will be unaffected. If the user requires debug, or would rather have debug available should further problems arise, restarting the mibd_interface process will prompt another attempt at debug initialization which may succeed. Before performing a process restart, the user should evaluate the likelihood of a restart resolving the problem. For example, if the error message indicates an out of resource condition, the user should look into and resolve any memory issues on the device before attempting the restart.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_5_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-AMBIGUOUS_PASSWD ### Response: (Severity: 3), (Category: SECURITY), (Description: Single digit passwords are not allowed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Cisco IOS XR Precision Time Protocol (PTP) feature? ### Response: The Cisco IOS XR Precision Time Protocol (PTP) feature allows synchronizing the clocks of network devices with high accuracy. It is based on the IEEE 1588 standard and provides sub-microsecond level synchronization, which is essential for applications such as mobile backhaul and financial trading. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_LWM_REPLY ### Response: (Severity: 7), (Category: FABRIC), (Description: An error occured while sending Ingressq LWM reply), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-TUPLE_UNKNOWN ### Response: (Severity: 3), (Category: OS), (Description: Unknown tuple.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support sysdb command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support sysdb output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-3-UPDATE_FAILED ### Response: (Severity: 3), (Category: OS), (Description: The Linux Packet classifier failed to program an update of Linux Socket bindings to its database or into LPTS. This may cause packets which should be handled by Linux applications to get dropped.), (Recommended Action: Periodic attempts to bring the databases back into sync will occur. An immediate resync can be trigger by restarting xlncd. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-2-DUI_VTP_FAILURE ### Response: (Severity: 2), (Category: PLATFORM), (Description: The NP ASIC has VTP issue. HW init will fail), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-NETWORK_MISMATCH ### Response: (Severity: 4), (Category: ROUTING), (Description: An OSPFv3 neighbor ID has been configured over an invalid network type.), (Recommended Action: Check the network type on the underlying OSPFv3 interface or area.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-DPA_SVR_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is a message in FIB platform to indicate that engine layer identified an error while programming an object in DPA.), (Recommended Action: Please collect the console log, show tech-support cef platform. Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-0-SCRATCH_TEST_EPM_SWITCH_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: This is to indicate that EOBC switch scratch register test has failed. This is thrown after consistent read or write failures to EOBC switch.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-ESI_FWD_MISCONFIG ### Response: (Severity: 3), (Category: L2), (Description: EVPN does not support more than one Forwarder (Bridge port) per EVI in a single ethernet segment unless the EVI is configured with AC aware VLAN bundling. This can be the result of a misconfiguration.), (Recommended Action: Review evpn and l2vpn configuration to determine where additional forwarders (bridge ports) have been configured for the same interface ethernet segment and same EVI, and remove them or configure the EVI with AC aware VLAN bundling.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_ASR9K_NSR_PACKET-2-NULL_HDR_AFTER_UNSCRAMBLE ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message tells is there was an error after unscrambling the packet and a NULL pointer has been returned.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERG-4-SWITCHOVER_ERROR ### Response: (Severity: 4), (Category: INFRA), (Description: The attempt to switchover role via administrative action has failed due to specified error. This is a warning that router is still in the old role. The use of force option can be done to force the role change overriding the error condition.), (Recommended Action: Check to ensure that the role switchover is still required to be performed and if so, repeat the operation using the force option. If error persists, then it is likely an issue and needs troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHER_CTRL-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message provides information about the kind of events happening in the software at the location where the error is seen. This is not an error message. Typically, following events are logged in this message type. - End of successfull initialization of the software. - Start and end of a processing of new object that needs to programmed to the hardware. - Configuration is not applicable to the port.), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN-4-FWD_LOOP_CFG ### Response: (Severity: 4), (Category: L2), (Description: A possible forwarding loop has been detected in the monitor-session configuration. This occurs when the source interface for one monitor-session is used as the destination for another. If this configuration were applied, it could result in unbounded traffic forwarding. As such, the interface that is both a source and a destination has its mirroring disabled in SPAN EA (i.e. it will continue to act as a destination for SPAN traffic, but not as a source). Use 'show monitor-session status' to identify the set of affected interfaces and to provide more information about their current state.), (Recommended Action: Double check the committed configuration for forwarding loops - an interface is not allowed to be both a source interface and a destination, regardless of the direction of the mirrored traffic.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-2-CPI_NOT_READY ### Response: (Severity: 2), (Category: PLATFORM), (Description: The shelfmgr could not initialize its card presence drivers. This can be caused by an improperly seated RSP card, or damage to the backplane pins.), (Recommended Action: 1. Please issue the following CLI command to switch away from this RSP and make the standby RSP active: admin redundancy switchover 2. Then reseat the RSP you switched away from very carefully into the chassis, making sure it makes full contact with the backplane pins. 3. During the maintenance window, then switch back to this RSP again and verify the error has gone away. If not, there may be an issue with either this card or the chassis backplane; please contact your Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-SYNC_CREATE ### Response: (Severity: 7), (Category: OS), (Description: When the single writer mode is set, RDS library allowes to create a ticket. When we tried to create ticket, we failed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-IF_IS_PART_OF_VRF ### Response: (Severity: 3), (Category: L2), (Description: Unable to assign interface because it is part of existing named VRF, first remove this association.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PDMA_SPP-3-THREAD_EVENT_BLOCK_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: DMAC driver failed to listen for packet events on its queue.), (Recommended Action: Restarting spp process on the affected card might solve the problem. To restart the spp process issue the following command on the card on which the error message is observed: 'process restart spp location ' Copy the error message exactly as it appears on the console or in the system log. Issue the show spp pdma trace all location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show spp pdma trace all location output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-3-CPU_CTRL_REG_LOCK ### Response: (Severity: 3), (Category: L2), (Description: Unable to obtain register access lock for CPU Ctrl.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers CPUCtrl ltrace <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers CPUCtrl ltrace <> output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-4-IFIB_RES_ALLOC_FAILED ### Response: (Severity: 4), (Category: OS), (Description: Failure in allocating platform-specific ifib result structure as a result packet is dropped.), (Recommended Action: Restarting netio may fix this issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-PKT_INT_ERR_AT_DDRIF_1_1 ### Response: (Severity: 1), (Category: FABRIC), (Description: Packet Integrity Error at DDR interface from Punt/Bridge-1 FPGA on FIA 1.), (Recommended Action: Verify correct version of Punt/Bridge FPGA is loaded. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-THREAD_SPURIOUS_PULSE ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS Recevied a spurious (unexpected) pulse value and will ignore it.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ACL-3-IPACCESSPTHREAD ### Response: (Severity: 3), (Category: ACL), (Description: The mutex used to protect access to the ACL data structure could not be locked or unlocked. The error message will include details of the particular failure. Possible causes of this failure are the mutex is corrupted, has not been initialised or is being accessed recursively (this is not allwowed). Because the mutex could not be used, the process may restart to recover from the failure.), (Recommended Action: Please try restarting the process that issued this error message with the command. process restart location . Process name should be printed in the message already.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-5-HA_INFO ### Response: (Severity: 5), (Category: PLATFORM), (Description: Display HA test info.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNVGEN_SHM_LOCK-3-GENERAL_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: General error in nvgen client library'), (Recommended Action: Collect the following logs and contact your technical support representative for assistance. a) Console messages b) show tech-support parser) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-6-MAP_SERVER_SITE_ALL_REGISTRATION_EXPIRED ### Response: (Severity: 6), (Category: IP), (Description: 'The Map-Server cannot forward Map-Requests to the site ETRs.'), (Recommended Action: 'Check the problem site ETRs to diagnose why ' 'the EID prefix registrations can not reach the MS.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-4-BVI_MAC_REPROGRAM ### Response: (Severity: 4), (Category: L2), (Description: We have detected an attempt by the control plane or by the local learning module to reprogram the BVI MAC as belonging to a different interface. This will break forwarding and therefore is disallowed.), (Recommended Action: - Check which host in the network might be advertising the BVI MAC - Check if the network is subject to a switching loop and/or L2 storm - Clear the locally learned mac address table; ( clear l2vpn forwarding mac-address-table ).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different MPLS TE FRR protection modes? ### Response: The different MPLS TE FRR protection modes are\n- Link protection: Protects against link failure. Backup tunnel is routed around the protected link.\n- Node protection: Protects against node failure. Backup tunnel avoids the protected node.\n- Best-effort protection: Tries to protect against both link and node failure, but does not guarantee it.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_EVM_CONN_OPEN ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-4-ERR_SYSDB_EDM_REG ### Response: (Severity: 4), (Category: FABRIC), (Description: The FIA driver was unable to become an external data manager (EDM) despite having a connection to SysDB. The operation will be retried.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-6-FIRMWARE_UPGRADE_PWR_CHECK ### Response: (Severity: 6), (Category: PLATFORM), (Description: 'System is checking power supply redundancy before proceeding'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VASI_EA-3-INITFAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of the VASI EA process on a particular node. The process will be restarted. Until the process starts successfully, any VASI interface pairs located on that node will not come up. (If there is a standby node the interfaces should come up on the standby).), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIO-7-ERR_MEM_ALLOC ### Response: (Severity: 7), (Category: PLATFORM), (Description: The EIO library was unable to allocate memory.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VEEA-4-BCMDPA_L1_PORT_UNSUPPORTED_LLFC_ON_PFC_ENABLED_INTF ### Response: (Severity: 4), (Category: PLATFORM), (Description: PFC and Flowcontrol co-existance is not supported. If flowcontrol is enabled on a PFC enabled interface, we dont reject the config but flowcontrol is not enabled in Hw and wont work as desired.), (Recommended Action: Unsupported config, fix config. For flowcontrol to work remove PFC config and remove/readd flowcontrol.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-7-DLRSC_UNKNOWN ### Response: (Severity: 7), (Category: OS), (Description: PlaceD was unable to get dLRSC from local lrd.), (Recommended Action: None - PlaceD should restart and recover by itself.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VERSMGR_LIB-7-SYSDB_BIND ### Response: (Severity: 7), (Category: INSTALL), (Description: A Version Manager library was unable to bind to SysDB (perhaps because the communications infrastucture is not yet up), so will not be able to function. Installations will be unlikely to produce the expected results.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FILECOPY_LIB-3-BAGENCODE ### Response: (Severity: 3), (Category: OS), (Description: An attempt to encode a filecopy bag failed. This may be due to like low memory. You may need to free some resources from other processes if the system is running low on memory - if freeing up resources does not fix the problem, please contact your customer support representative and file a bug against the infra-filecopy-srv component.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_LRD_SPA-3-STATE_UPDATE ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occured while processing a SPA state or type change notification. Service interfaces configured on the given SPA may not be appropriately (un)replicated.), (Recommended Action: Restarting the process in question should rectify the situation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEv2-3-AUTH_VERIFY_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: With IKEv2 certificate authentication, sender(initiator/responder) needs to sign the AUTH DATA using the private key corresponding to the leaf certificate, receiver will use the public key of senders X509 certificate to validate the sender's AUTH payload this error will be printed when certificate is not received as part of AUTH payload or certificate is expired or certificate is not yet valid or certificate verification failed or signature verification failed or issuer certificate is not known), (Recommended Action: On Receiver, ensure valid trustpoint with senders issuer certificate is present, example: clear the old certificates from trustpoint using 'clear crypto ca certificates ' and re-authenticate and re-enroll the trustpoint for generating new certificates using 'crypto ca authenticate ' and 'crypto ca enroll '.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to enable LDP session protection? ### Response: To enable LDP session protection, use the 'session protection' command under the MPLS LDP configuration. RP/0/RSP0/CPU0:router(config)#mpls ldp RP/0/RSP0/CPU0:router(config-ldp)#session protection <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-6-UPDATE_STARTED ### Response: (Severity: 6), (Category: LICENSE), (Description: Entitlement update from consumption model has started.), (Recommended Action: 'INFO') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-7-CAN_INFO ### Response: (Severity: 7), (Category: PLATFORM), (Description: This message indicates CAN bus information related to on-line/off-line CBC processor transitions.), (Recommended Action: No action required; the message is informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HYPHY_FRAMER-4-HYPHY_EXCEPTION ### Response: (Severity: 4), (Category: OS), (Description: whenever any API is fail due to NULL,any API return NULL or any API fail due to creation of memory using malloc and calloc corresponding traceback is printed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. required_info: This error message, along with full console logs. Details of the operation that was occurring when this error was seen. Output of: - 'show tech-support otn') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-PID_JOBID_CONVERT_FAIL ### Response: (Severity: 3), (Category: HA), (Description: Failed to get JOBID from PID.), (Recommended Action: Collect show tech watchdog and show tech sysmgr contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-XFP_LNK_FAULT_ERROR_6 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the XFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. Do XFP OIR. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_BACKEND ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the Backend service related to use of either SysDB or SubDB. The error message describes what operation has failed and why it failed. The most likely reason for this is low memory resources or a programming error.), (Recommended Action: Consider restarting the PPP MA process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_1_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser bias greater than or equal to the high laser bias alarm threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTR3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp bestpath med always' command in IOS XR BGP configuration? ### Response: The 'bgp bestpath med always' command is used to always compare the Multi-Exit Discriminator (MED) values for paths from external BGP (eBGP) peers. By default, MED comparison is done only if the paths are from the same autonomous system (AS). This command allows MED comparison for paths from different AS, enabling the selection of the best path based on MED even if the paths are from different AS. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-TCAM_INIT ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when trying to initialize TCAM regions.), (Recommended Action: Check the status of TCAM Manger because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Debug library initialization failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAN-3-DRIVER_ERROR_MSG ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This might be a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-PORT_CREATE_FAILED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The SockIO SPP plug-in failed to create a port in its local database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-SDR_TRIGGER_SYSTEM_RELOAD ### Response: (Severity: 6), (Category: INSTALL), (Description: Specified install operation needs explicit System reload for [de]activation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACE_LC-2-ACE_SYSLOG_CRIT ### Response: (Severity: 2), (Category: SECURITY), (Description: ACE SPA SYSLOG message), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_4_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-SWITCH_INTERNAL_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process detected internal error which causes the switch to not forward the packets reliably. In order to recover, the ESD process resets the switch, then exits so that it is restarted by the process manager.), (Recommended Action: If this problem does not recur, no intervention is required to recover. To determine why this problem occurred, or if the problem occurs multiple times, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet' and 'show tech-support ctrace' commands. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR-6-ENET_LINK_DOWN ### Response: (Severity: 6), (Category: PLATFORM), (Description: Link physical link is down, no need to recover, just wait for physical link comeback (LC only)), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PA_FF-4-CLIENT_NOT_FOUND ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when trying find the internal client structure for a given operation.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPGAMGR-7-INIT_COMPLETE ### Response: (Severity: 7), (Category: PLATFORM), (Description: The FPGA Manager, init completed. %s-Message Description.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAAD-6-STATE ### Response: (Severity: 6), (Category: MGBL), (Description: An change state occurred in the aaad.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_SERVER-1-UPGRADE_ALERT ### Response: (Severity: 1), (Category: INFRA), (Description: Update FPD upgrade alert), (Recommended Action: Customer immediately knows the upgrade status.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA-4-WARN_RANGE_RETRIEVAL ### Response: (Severity: 4), (Category: L2), (Description: A repeated failure occurred when requesting the range of available MAC addresses. A zero size range will be used, resulting in any MAC address requests from client features being rejected.), (Recommended Action: *DDTS*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APPMGR-4-RPM_SIG_CHECK_FAILED ### Response: (Severity: 4), (Category: INFRA), (Description: The IOS-XR appmgr has failed to verify the signature of the specified RPM, but will proceed with the installation anyway.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-3-MPA_PHY_INIT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: MPA PHY initialization failed.), (Recommended Action: Copy the error message exactly as it appears on the screen and gather the output of the CLI 'show tech-support ethernet interfaces'. If the issue persists, contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-0-RSP_OCXO_FAILURE_ALARM_FATAL ### Response: (Severity: 0), (Category: PLATFORM), (Description: Clock derived from OCXO is not proper. There could be instability in system due to bad clock received. Reloading the board to switch over to RSP in hot-standby.), (Recommended Action: Contact Cisco-TAC for further investigation/recovery action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-EBS_OC_CRC_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: EBS from FIA CRC error.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-ADJACENCY_DEL_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'CTRLIO Adjacency delete failed.' 'deleting shared memory entries failed.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_AGG-3-FRA_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB aggregator failed to initialize FRA library with above reson.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BOOTVAR-7-CANT_WRITE ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the NVRAM file system is in error, or the boot-variable infrastructure is behaving incorrectly. A file required for carrying out the current request or operation could not be written to, so processing of the operation will halt. The boot variables may not be available to the system.), (Recommended Action: Check NVRAM filesystem for corruption using the 'fsck' disk check CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-RX_CH_LOS_ERR ### Response: (Severity: 3), (Category: FABRIC), (Description: The Rx POD detects a loss of signal on a channel. This can be due to: [1] The link is configured by software to be receiving cells with an invalid transmit end [2] The link is not physically connect to the Tx side. For [1], it is a software bug where a Rx link should only be configured if it has a valid transmit end. For [2], if the Rx channel suddenly sees this without any physical change of the optical cable or shut down of the other end, then it is likely the POD channel has become defective. If the optical cable connecting the POD is cut, then the Rx POD will see loss of signal.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-7-TIMER_CREATE_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to create timer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the Secure Shell (SSH) in Cisco IOS XR? ### Response: SSH in Cisco IOS XR provides a secure method for remote management and configuration of devices by encrypting the session to prevent eavesdropping, tampering, or message forgery. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-NODE_BOOT_OPTIONS ### Response: (Severity: 6), (Category: INSTALL), (Description: This message indicates the boot options of the specified node.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-FAN_TRAY_PRESENT_CHK_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The fan tray present check has failed due to specified reason, will be returning 'NOT PRESENT' from the funtion.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_15_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-3-HW_RES_OVERFLOW ### Response: (Severity: 3), (Category: PLATFORM), (Description: NP entry exceeded the maximum number of resources available.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-ASIC_HALTED_VIA_FPGA ### Response: (Severity: 6), (Category: FABRIC), (Description: The specified device is halted using the FPGA register.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-MAP_SHM_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath was unable to map shared memory. This is usually caused when the system is low on resources. This error could occur for two reasons. 1. The system is low on resources. 2. Error in the DPAA software.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect show log location output, show controllers dpaa trace all location output and show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-XFP_LNK_FAULT_ERROR_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the XFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. Do XFP OIR. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the pkgfs process in IOS XR installation? ### Response: The pkgfs process in IOS XR provides file location information to processes that need to know where files are physically located. It abstracts the locations and versions of the files and provides a virtual location known as a loadpath to the node so that the software can be run. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-3-CONDVAR_OP_FAILED ### Response: (Severity: 3), (Category: OS), (Description: 'Current operation on the condition variable has failed.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLUSTER_LAYOUT-4-MINIMUM_RACK_REQUIREMENT_NOT_MET ### Response: (Severity: 4), (Category: INFRA), (Description: Cluster layout file doesn't have minimum number of racks required for the corresponding cluster size.), (Recommended Action: Update the Cluster layout file to satisfy minimum rack requirement. Cluster reload will be needed for the new layout file to take effect.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTP9 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_IMC_CONTROL_SERVER_BIND ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHDLC_MA-4-ERR_THREAD ### Response: (Severity: 4), (Category: L2), (Description: A failure occured during thread handling.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-3-SPA_DISABLE ### Response: (Severity: 3), (Category: L2), (Description: This is an error message indicating a Hardware access error for a SPA and disable the SPA to avoid LC reload), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-SYSMGR_ERR ### Response: (Severity: 3), (Category: L2), (Description: Some error occured while interacting with sysmgr. The text of the message displays the failed operation with error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_0_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LICENSE-6-ENFORCE_DISABLED ### Response: (Severity: 6), (Category: LICENSE), (Description: Smart Licensing is disabled.), (Recommended Action: The customer should enable smart licensing.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_ATOM-7-INIT_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the ATOM module in the platform L2FIB ATOM component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LMRIB_API-3-GEN_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Error occurred in lmrib client lib. This could be a memory error, thread lock fail or a problem that the LMRIB client is unable to register with LMRIB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show lmrib client trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show lmrib client trace output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-AUTH_RENEW_FAILED ### Response: (Severity: 3), (Category: LICENSE), (Description: The Authorization renew request failed. This may have caused due to wrong Smart Call Home settings or network connectivity failure to cisco.com.), (Recommended Action: Please check the smart agent syslog file for more information. Please turn on the smart agent debug mode and retry again for additional information. Also, please check the Smart Call Home settings and network connectivity to cisco.com.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-GENERIC_FAILURE_MSG ### Response: (Severity: 7), (Category: OS), (Description: This is a generic error msg.), (Recommended Action: This is a Debug message . No action required. If the problem persists , contact Support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHOWCMD-3-VALIDATE_MSG ### Response: (Severity: 3), (Category: SNMP), (Description: 'The failure pertains to show commands in snmp to validating the data ' 'This does not indicate feature failures or issues'), (Recommended Action: 'This log does not indicate a system impact.' 'all show snmp CLI's for debugging purpose only' 'Recommend customer to re-try the command.' 'If there is no output, reconfigure the snmp settings and re-try') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-DIE_OVERTEMP_CRITICAL ### Response: (Severity: 2), (Category: PLATFORM), (Description: LC on die temperature sensor is risen above or fallen below critical threshold.LC or Port will be shutdown in 24 Hrs), (Recommended Action: Verify the failure, use show env to help. If the failure does not alleviate, LC or port will shutdown. Call your technical support representative for repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_MA_PWHE-3-INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: An error has happended while initializing L2VPN MA PWHE process. pwhe_ma will be restarted automatically.), (Recommended Action: The process should recover automatically and no further user action is required. If problem persists, please collect 'show tech-support l2vpn' and contact Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-BUFFER_OVERFLOW ### Response: (Severity: 3), (Category: MGBL), (Description: 'buffer overflow'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTY-7-DATA_PATH ### Response: (Severity: 7), (Category: MGBL), (Description: An unexpected error occurred when the VTY Device DLL asked the TTY Server to perform a Data Path operation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM_OFFLOAD-4-STATS_DROP ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: An error was encountered while attempting to deliver statistics to the Connectivity Fault Management (CFM) protocol. This is a transient problem from which the system should recover, but CFM statistics may be incorrect until it does. This may indicate the system is under unusuallay high traffic load.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-PROCESS_CORE_FOR_DEBUGGING ### Response: (Severity: 6), (Category: INFRA), (Description: The command took longer than expected and so was timed out. In order to triage the delay, a core was created for future debugging. Details of this core can be found in the recent COREHELPER syslogs.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The original install operation will have failed due to the command timing out (not by the core itself). Re-running the install operation should work.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-4-NO_MEMORY ### Response: (Severity: 4), (Category: OS), (Description: Not enough memory available in the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEATURE_LPTS-3-UNKNOWN_FGID_DB_ERROR ### Response: (Severity: 3), (Category: FABRIC), (Description: A software error occurred, when the PA(Port Arbitrator) attempted to Allocate, free or join FGID from the FGID Aggregator.), (Recommended Action: The process lpts_pa will attempt to recover by retrying the operation. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_API-7-ERR_ECM ### Response: (Severity: 7), (Category: FABRIC), (Description: The FIA driver client library encountered the annunciated error condition. There are 3 types of this failure. - ECM create failure: In this case the FIA driver client library will not be able to connect to the FIA driver. - Register notification handler failure: In this case the FIA driver client library will not receive notification of ECM events. - Failure to open a connection:), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rlogin-3-ERR_SOCKET ### Response: (Severity: 3), (Category: IP), (Description: Socket operation failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB-4-LTRACE_INIT_FAIL ### Response: (Severity: 4), (Category: FABRIC), (Description: ltrace initialization failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_16P_OC48-3-PORT_UNMAP ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to delete or unmap SONET port.), (Recommended Action: Check the process plim_16p_oc48 . plim_16p_oc48 process is driver of LC.If this process is crashed then packet may be dropped in LC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WANPHY-4-ALARM ### Response: (Severity: 4), (Category: L2), (Description: The specified WANPHY Alarm has been declared or released. interface: interface on which alarm is set/cleared alarm: alarm being asserted e.g: SF-BER or SD-BER status: set/cleared), (Recommended Action: If SF/SD-BER alarm is seen: Link quality degraded beyond configured threshold. Check if the peer end is injecting error packets else check if the cable is faulty. Collect sh controller wanphy <> all and verify if B2 errors are incrementing. If B2 count is incrementing the alarm is seen because of peer end is injecting error packets or faulty link) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: S2681-6-STAT_CREATE_ERROR ### Response: (Severity: 6), (Category: MGBL), (Description: The S2681 UART driver was unable to create a file to store statistics. Show statistics command would fail. We can still see the statistics content from core file.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICLIB-4-TRACE_INIT_FAILED ### Response: (Severity: 4), (Category: LICENSE), (Description: The license client library could not initialize internal tracing used for technical support.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_NTP-3-EXCEED_MAXFREQ ### Response: (Severity: 3), (Category: IP), (Description: Frequency Error exceeded NTP tolerable limit (500 PPM).), (Recommended Action: Try to reset the drift value by ntp reset drift. If this message recurs after resetting the drift value, see show ntp associations, correct information for all the peers, contact your Cisco Technical support, and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UTIL_ASSERT-6-DUMPING_CORE ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: An unexpected event occured in the process specified, and so a running core dump has been taken. This is not expected to have any functional impact, but should any problems be seen then this core will aid debugging.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-CALLING_PLATFORM_RELOAD_NODES_SPECIFIC ### Response: (Severity: 4), (Category: INSTALL), (Description: The install manager needs to call the platform API to reload the ndoes listed, in order to complete the parallel install operation. If the call fails, the user may have to manually reload each node manually, by calling reload location from admin mode), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_2_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Tx power greater than or equal to the high Tx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Tx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Replace the QSFP+ with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRG-5-ACTIVATION_COMPLETE ### Response: (Severity: 5), (Category: SUBSCRIBER), (Description: The activation of subscriber sessions on the SLAVE has been completed. This is either in response to CLI command or a dynamic failure trigger on a SLAVE which has been configured as a warm-standby.), (Recommended Action: None required if there has been any network event or administrative action that caused this activation of sessions. Subscriber status may be checked on the slave router to verify consistency, if desired.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: deflate-3-output_non_directory ### Response: (Severity: 3), (Category: OS), (Description: The uncompression output is not a directory. The output for multiple files uncompression needs to be a directory.), (Recommended Action: Please check the command syntax for the output to be a directory if it is from a user entered CLI. Please capture show log and error messages if the error is not due to user entered CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_EDM-3-NO_STATS ### Response: (Severity: 3), (Category: L2), (Description: The statistics manager returned null data for Virtual-Circuit (vc), a Non-Zero, not-Null value is expected. Operation Failed for the reported Data-Link Connection.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-4-REMOTE_CORE_ISOLATION_CLEAR ### Response: (Severity: 4), (Category: L2), (Description: ICCP-SM has recovered from remote core isolation and has attempted to recover the ports in the redundancy group.), (Recommended Action: This message may not require any action. However the show l2vpn iccp-sm group group-num command may be used to verify the state of the ICCP-SM core interfaces. Reference the L2VPN ICCP-SM section of the IOS XR documentation for details on core isolation failures and related configuration commands.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-4-ERR_MRIB_SEND_RESPONSE_RETRY ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-6-COLD_BOOT ### Response: (Severity: 6), (Category: PLATFORM), (Description: In recovery from a system restart, a powercycle has been successfully initiated on this slot.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_ECSR_0 ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an eCSR0 access error.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-5-FSM_DISCARD ### Response: (Severity: 5), (Category: IP), (Description: A valid formatted ANCP packet was received for an adjacency, but is unexpected given the state the adjacency is currently in.), (Recommended Action: The ANCP protocol is written to handle such events by discarding the packet. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT-2-XAUI_IF_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Punt xaui interface has failed.), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. Please verify that the FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you configure PTP in Cisco IOS XR? ### Response: To configure PTP in Cisco IOS XR, use the 'ptp' command followed by the PTP profile (such as G.8265.1 or G.8275.1) and the clock type (ordinary, boundary, or transparent). You can also configure PTP parameters such as the domain number, priority1 and priority2 values, and announce interval using the 'ptp' command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-IM_NAME_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_GROUP_CREATE ### Response: (Severity: 3), (Category: OS), (Description: A call to a group services interface failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_MGR-3-UNABLE_TO_RECONNECT ### Response: (Severity: 3), (Category: SERVICES), (Description: If the Service Infrastructure becomes out of sync with IM, then it reconnects in order to prompt a resync. If this message is displayed then it has been able to reconnect. This may cause configured interfaces to no longer forward traffic, or interfaces which have been shut down or deleted to continue to do so.), (Recommended Action: Restarting the process that displayed the message may solve the issue, or restarting ifmgr. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP-3-EMWEB_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The EmWeb code has encountered an error condition or state. The HTTP process may no longer be able to function correctly, and may need restarting if the errors persist.), (Recommended Action: Restart http server if the errors persist.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CBC-3-VERSION_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The CBC on the slot has an incorrect firmware type programmed. The firmware major version does not match the card type.), (Recommended Action: Try cbc fpd force upgrade on this node and then reload this node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-SIGFPE_INFO ### Response: (Severity: 4), (Category: OS), (Description: Signal info), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-3-SECURE_MODE_DISABLE_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: Failed to disable ZTP on secure mode.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-ACL_GET ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred when trying to get the named prefix-list.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-MISSSTARTOBJECT ### Response: (Severity: 4), (Category: MGBL), (Description: The command entered requires naming information of start and one was not supplied.), (Recommended Action: Use the help command to determine the correct usage for this command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CSCMIB-3-CSC_SNMP ### Response: (Severity: 3), (Category: SNMP), (Description: The SNMP management station tried a set request without specifying a request index. Check the request and try again.), (Recommended Action: Check the request and retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT-2-CPU_RGMII_RX_LINK_FAIL_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: 125Mhz clock has failed.), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. Please verify that the FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEv2-6-PRESHARED_KEY_MISMATCH ### Response: (Severity: 6), (Category: SECURITY), (Description: Failed to bringup IKEv2 session due to mismatched keys on both peers.), (Recommended Action: for PSK method, configure same preshared keys on both ends.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_6_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-3-HIGH_THRESHOLD_LARGER_THAN_WINDOW ### Response: (Severity: 3), (Category: L2), (Description: For high threshold events to be possible, it is required that the number of possible errors in the configured window is at least as large as the high threshold, which is not currently the case. Note that when window size or threshold is specified in frames or symbols, its length in milliseconds depends on the maximum bandwidth.), (Recommended Action: Consider changing the relevant configuration (i.e. the window and/or high threshold size).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPHC_MA-3-MEM_ALLOC ### Response: (Severity: 3), (Category: L3), (Description: The process failed to allocate memory for the specified resource.), (Recommended Action: Check how much memory is available at the location where the error was reported. If the system has enough memory and if the error message persists, contact TAC with required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the Qnet protocol in IOS XR? ### Response: Qnet is a protocol that enables transparent inter-node communication for IPC mechanisms like LWM. It allows processes to communicate over the control network without being aware of node boundaries. Qnet provides location transparency using a virtual bus abstraction and hides the details of marshaling messages between nodes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-5-MSTATS_ALLOC ### Response: (Severity: 5), (Category: OS), (Description: It failed to allocate HW counters. It may be because of running out of HW counters or encountering internal error.), (Recommended Action: Disable the numbers of non crucial services which use HW counters.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLUTLU-4-REPL_MODE_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: An error was encountered while trying to modify replication mode on linecard), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM_PLIB-3-EVENT_SET_RETRY_FAILED ### Response: (Severity: 3), (Category: IP), (Description: A call to set the retry timeout for producers to bind with iparm failed. This will call default timeout values to be used.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-RPL_INIT ### Response: (Severity: 7), (Category: SYSDB), (Description: An unexpected error occurred during initialisation of the replicator module.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-4-SPAWN_FAILURE ### Response: (Severity: 4), (Category: MGBL), (Description: An executable was not spawned due to the mentioned error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-MMAP ### Response: (Severity: 3), (Category: MGBL), (Description: 'mmap of file'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_0_EGR_Q_ERR_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Egress queue error on NPU-0 interface on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM_LIB-3-SERVICE_ENTRY_NOT_AVAILABLE ### Response: (Severity: 3), (Category: OS), (Description: New service can't be registered due to memory exhaustion. Need to fix source code to accept more services.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_THREAD_COND ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an unexpected error performing a condition operation. The process may restart to attempt to recover. This is possibly due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PMLIB-4-WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: svc pmlib encountered an provisioning warning.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect 'show log location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-1-ZERO_CAPACITY ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Capacity in the IDPROM is zero.'), (Recommended Action: Try restarting the using CLI command in exec mode - process restart pwr_mgmt If the error exists try -insert and re-insert the PM If the error exists - Replace the power module) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_PW-6-STANDBY_READY ### Response: (Severity: 6), (Category: L2), (Description: L2VPN Pseudowire state is changed to standby-ready.), (Recommended Action: If the state change was unexpected, verify the configuration settings for the cross-connect.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR_ASIC-4-JER2_INTERRUPTS_DISABLED ### Response: (Severity: 4), (Category: FABRIC), (Description: J2 A0 asics detected, only frr testing intr enabled), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-7-PFI_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to register with PFI infra in the platform L2FIB component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_AAA_SESSION ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA encountered an error using AAA session APIs. The error message describes what operation has failed and why it failed. The most likely reason for this a low memory condition but the error could also be caused by a programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-ACCESS_VFI_PW_MATCHES_EVI_NEIGHBOR ### Response: (Severity: 3), (Category: L2), (Description: Interop/seamless integration is not supported for Access VFI Pseudowires. Therefore, configuring an Access VFI PW with a neighbor matching an EVPN EVI neighbor under the same bridge domain is an unsupported config that can lead to unexpected behavior.), (Recommended Action: Unconfigure either the indicated EVI bridge port or the Access VFI PW from the affected bridge domain to clear the misconfiguration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMAEDM-3-EVENT_CONN_CREATE_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Internal error), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-SYSADMIN_VM_ERROR_EVENT ### Response: (Severity: 3), (Category: DRIVER), (Description: SysAdmin VM has reported a error event.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-4-LNS_LOP_DROP ### Response: (Severity: 4), (Category: FABRIC), (Description: Ingressq dropped a few cells because of unavailability of enough planes to forward the cells to its destination. If the cells are dropped intermittently during system reconfiguration (LC reload, RP fail over, etc), then these drops are expected. System will recover after the hardware reprogramming completes. If these drops are seen continuously for long periods, then this indicates that either the node is not programmed correctly, or there is an error in data plane software.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-IDB_INIT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace im error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace im error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-5-OIR_ACTION ### Response: (Severity: 5), (Category: TOPOLOGY), (Description: System Admin Manager got notification that a card has been inserted or removed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-3-INVALID_SLOT ### Response: (Severity: 3), (Category: L2), (Description: The slot number is invalid), (Recommended Action: The slot number should be less than 15) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-THREAD_CREATE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath failed to create the mentioned thread. This error could occur for two reasons. 1. The system is low on resources. 2. Error in the DPAA software.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect show log location output, show controllers dpaa trace all location output and show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_PRM-3-SIGNAL_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The specified PRM worker thread encountered the signalling error.), (Recommended Action: Please collect output of the following commands: show platform show log show process blocked location <> show controller rm prm client trace all location <> show controller rm prm process location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the OSPF router dead interval and how is it related to the hello interval? ### Response: The OSPF router dead interval determines how long to wait before declaring a neighbor down if no hellos are received. By default it is 4 times the hello interval, which is 40 seconds for broadcast/p2p and 120 seconds for NBMA/p2mp networks. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-PLANE_MISMATCH ### Response: (Severity: 3), (Category: SECURITY), (Description: The username has to be unique across the Admin and LR plane.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROL_DRIVER-3-IM_PD_INIT_FAILURE ### Response: (Severity: 3), (Category: DRIVER), (Description: Interface Module PD initialization failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_UTIL-3-FAIL_DEBUG_REG ### Response: (Severity: 3), (Category: MEDIA), (Description: NVRAM debugging service register to sysdb failed.), (Recommended Action: Check the existence of the Sysdb service. The system is supposed to re-register if the Sysdb service is available.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-EARLY_ACTION_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: An unexpected error was encountered at the start of an action command. The action has not taken place and system state was not updated. The install infrastructure has restarted to recover. Please try the install command again.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ITAL-2-THREAD_LOCK_FAILURE ### Response: (Severity: 2), (Category: OS), (Description: An effort to lock database failed. The function which tried to lock as well as the function holding the lock are given in the message.a The database might not reflect the expected behavior.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-4-AUTOROUTE_DESTINATION_DEPRECATED_CONFIG ### Response: (Severity: 4), (Category: ROUTING), (Description: This configuration was replaced with an alternate \ and will be removed in a subsequent release.), (Recommended Action: Please do not use this form of autoroute destination configuration anymore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SATORI-3-GET_BOARD_TYPE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Satori get board type has failed and it might not boot up), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-EVENT_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: An unrecoverable error occurred during the event loop.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show processes msdp detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes msdp detail output, call your Cisco technical support representative and provide the representative with the gathered information. Using the Job ID from the above command, please run the following command: Copy the error message exactly as it appears on the console or in the system log. Issue the show evm trace jid errors command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show evm trace jid errors output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace events command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace events output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COREHELPER-3-NO_INFO_FOR_COPY ### Response: (Severity: 3), (Category: OS), (Description: DLRSC infomation is not available, can't copy core file.), (Recommended Action: Check dumper process, collect console message. Report this message to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-3-INVALID_PORT ### Response: (Severity: 3), (Category: DIAG), (Description: A diagnostic request is being made on a port that does not exist.), (Recommended Action: Ensure the specified port number exists and that the correct port number is being specified.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-5-ISOLATION_CLR ### Response: (Severity: 5), (Category: L2), (Description: At least one configured core interface for the EVPN group is up.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-NO_OUTSTANDING_BMA_REQ ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: EINT received a BMA interrupt indicating a response to a BMA buffer request but there was no request made), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-2-PROC_FAIL ### Response: (Severity: 2), (Category: L2), (Description: During process start up an unrecoverable error occurred. The component will exit and should be restarted by the System Manager.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_MISSEVENT ### Response: (Severity: 4), (Category: SYSDB), (Description: The command entered requires a notification event type and one was not supplied.), (Recommended Action: Use the help command to determine the correct usage for this command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CATAPULT-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: CATAPULT Driver encountered a fatal error and is not able to recover. The supplied text string will explain the reason. Call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_ERRNO ### Response: (Severity: 3), (Category: SECURITY), (Description: Error description, error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA-4-ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the process. This resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_CLI-7-JID_GET_ERROR ### Response: (Severity: 7), (Category: OS), (Description: process's JobID can not be obtained), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_UV-3-MISCONFIG ### Response: (Severity: 3), (Category: L2), (Description: The FR Uberverifier process has detected a misconfiguration. It was not detected in the verification phase, so the Uberverifier process cannot correct this.), (Recommended Action: The misconfiguration can be corrected by deleting all configuration from the specified interface and its subinterfaces, and then reapplying the configuration. If the problem persists, do the following: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_BDI_DEMB ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LINK-4-BERTSTART ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: BERT could not be started), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRG-4-DSCP_VALUE_NOTSET ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The SRG Packets Priority will not be set.), (Recommended Action: Refer the SRG Configuration document.Recommend to use NTP configuration documents.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: adminexec-3-SYSDB_BIND_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_5_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_LIB-4-MESSAGE_NOT_PROCESSED ### Response: (Severity: 4), (Category: INSTALL), (Description: A part of the install infrastructure has been waiting for the stated time for the install director to be able to process the image. This can happen if other processes are taking a long time to initialize.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-3-ERR_BAD_PORT ### Response: (Severity: 3), (Category: IP), (Description: The telnetd server was passed a bad port number.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-6-ERRDIS ### Response: (Severity: 6), (Category: PLATFORM), (Description: Front panel SFP port is UDLD Uni-Directional, check sfp/fiber for errors), (Recommended Action: 'Check if the media (fiber / sfp) has any errors') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_9_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power greater than or equal to the high Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-6-SYS_NOT_READY_CLI ### Response: (Severity: 6), (Category: MGMT), (Description: This is expected when connection to configuration database is down, if this message even though configuration database is up, please), (Recommended Action: The program tries to re-connect the directory service, once directory service is up, this message will not come up, If configuration databse is up and still this message comes, the work-around would be restart program) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rspp_rio_netio-3-TERM_FAILED ### Response: (Severity: 3), (Category: SERVICES), (Description: The service ingress diversion NetIO DLL termination function failed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option verbatim feature? ### Response: The MPLS TE path-option verbatim feature disables the default behavior of automatically assigning IP addresses to unnumbered interfaces in an explicit path. With verbatim, the explicit path is used exactly as configured without modification. This is useful when the automatic IP address assignment conflicts with intended explicit paths. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN_EA-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: An unexpected condition was detected in the Platform SPAN module.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-6-INFO_I_AM_DSC ### Response: (Severity: 6), (Category: PLATFORM), (Description: Informational message notifying current DSC in system), (Recommended Action: This is an informational message. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDLD-5-UNIDIRECTIONAL_LINK ### Response: (Severity: 5), (Category: L2), (Description: The UDLD protocol has detected a problem with this link: It is unidirectional. The link will be disabled.), (Recommended Action: Correct the link fault, then re-enable UDLD using the following command: - ethernet udld reset interface ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ_MGR-7-ERR_LWM_EVENT_BLOCK ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabricq Event Manager event block error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-ACTION_IN_ACL_NOT_SUPPORTED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The following actions in an ACL are not supported in the direction specified: log-input (ingress/egress) log (egress)), (Recommended Action: remove the action(s) from ACL and re-apply) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_14_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_14 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-LM75B_INIT_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to LM75B init failure . This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-IPSEC_DEBUG_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred when trying to initialize the ipsec debug commands.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_MGR-3-INIT_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The SVI Adjacency Manager's initialization has failed. The process will exit and automatically restart.), (Recommended Action: The message may be displayed due to low memory condition in the system. Check the output of show mem summary and take necessary action. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON_EA_OOR-4-NP_FLOWS_OOR_GREEN ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-3-PCI_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The DMAC device encountered PCI errors.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-CHKPT_FAILED_GO_ACTIVE ### Response: (Severity: 3), (Category: L2), (Description: After an RP switchover and/or HA role change, CFM failed to notify Checkpoint that the current CGM process is the active version. This means that the CFM Global Manager process does not have write access to the checkpointed data. Hence, MIB index values for Domains and Services configured after this point will not persist across process restarts.), (Recommended Action: CFM should continue to operate normally. However, newly-configured Domains and Services will not have their MIB indices stored in the checkpoint database. Restarting the CFM Global Manager process may resolve the problem. The CFM Global Manager can be restarted by issuing 'process restart cgm' on the affected node. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-MULTIPLE_ISOS_IN_INPUT_LIST ### Response: (Severity: 3), (Category: INFRA), (Description: Multiple ISO's have been provided in input list. Invalid input.), (Recommended Action: Skim through the input list again and include relevant and appropriate ISO.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_CPP_PM_TEST-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: sip_pm test encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: This is a test software for internal use. So, there is no actiom required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IPV4_EA-5-DEBUG ### Response: (Severity: 5), (Category: PLATFORM), (Description: This is an information message in the ASR9K platform specific code software. The message is for debug purposes only and not an error.), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_UTIL-5-LTRACE_INIT2 ### Response: (Severity: 5), (Category: HA), (Description: Failed to register ltrace context structure. Tracing will not be functioning properly.), (Recommended Action: Tracing will not work properly. Process will proceed running. Can restart the process to overcome this issue. IF error persists.Collect the error log with return value and core dump of the process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-3-CFS_NATIVITY_CLEANUP ### Response: (Severity: 3), (Category: MGBL), (Description: Local CFS is non-native and automatic cleanup of it has failed.), (Recommended Action: Run 'commit replace'. If contacting support, please provide trace information from executing command 'show cfgmgr trace location ' for the node with this problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPV6-6-SUSPICIOUS_PD_DELETE_REQUEST ### Response: (Severity: 6), (Category: IP), (Description: Received a DHCPv6 Release/Decline message from a suspicous client and ignored the message to be safe. It could be a spoofing attack.), (Recommended Action: Find who sent this message) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMITH-3-EVENT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Some error encountered like initialization failure or connection failure), (Recommended Action: Please collect the 'show logging' output.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RAW-7-SYSDB_INIT ### Response: (Severity: 7), (Category: IP), (Description: An software error occured when the RAW process try to do initialization related with sysdb process.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-CARD_SHUTDOWN ### Response: (Severity: 4), (Category: PLATFORM), (Description: The hw-module in the given location is being shut down for the given reason), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-6-EVENT_MGR_UNKNOWN_EVENT_RCVD ### Response: (Severity: 6), (Category: IP), (Description: The event manager has received an unknown event.This is not system impacting,the system will continue to funtion normally.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-3-SHM_FREE_ERR ### Response: (Severity: 3), (Category: L2), (Description: The platform-dependent FIB failed to free shared memory due to a version mismatch. This could eventually lead to memory exhaustion.), (Recommended Action: Try restarting the process using the command- process restart l2fib_mgr Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK_LIB-6-GSP_SEND ### Response: (Severity: 6), (Category: OS), (Description: A call to group_send() failed. There could be a problem connecting to underlying gsp server or transport between RP and LCs. If this is seen for a long time, there might be a real issue.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-3-FWC_WAVL_DELETE_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: A call into the IOS-XR WAVL tree library failed. This may result in the firewall controller unexpectedly restarting after this message is seen.), (Recommended Action: If the process unexpectedly restarts, this will clear the problem; otherwise no further action is necessary to recover. In either case, please copy the message exactly as it appears on the console or in the system log, along with any subsequent messages relating to process restart and the information detailed below, and call your Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install boot-options command in IOS XR? ### Response: The 'install boot-options' command is used to modify the boot options for the next router reload. It allows specifying the image to boot from and other boot-related parameters. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-CHKPT_UNREGISTER ### Response: (Severity: 3), (Category: OS), (Description: chkpt_unregister failed while unregistering the chkpt table.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_STORM-3-SC_EXIST_ERR_IFH ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to program storm control as it is conflicting with an existing AC), (Recommended Action: Remove storm control config on this sub-interface) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-3-ERR_IM_MTU_REGISTER ### Response: (Severity: 3), (Category: L2), (Description: CDP failed to register with the interface manager for MTU size changes on this particular interface. This may cause problems sending CDP packets.), (Recommended Action: Perform 'cdp disable', 'cdp enable' on the interface to try to recover. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_15_LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_SEC ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from SEC.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_BCDL_CONSUMER-7-ERR_LTRACE_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: The FGID BCDL Consumer could not open the annunciated ltrace buffer. The FGID component and the system should function as normal, with the exception that ltrace will not be available for FGID BCDL Consumer process.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCTRL-3-CMD_EXEC_ERROR ### Response: (Severity: 3), (Category: LIB), (Description: Failure returned by command), (Recommended Action: Collect 'show tech-support ctrace' and show tech HBLoss output.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-BARBARIAN_VOLT_FIX_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: VP4 rail on the SPA could not be margined to nominal voltage due to some failure.), (Recommended Action: SAR chip SRAM parity errors might result. Margin the rail manually.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-BAD_FPD_IMAGE ### Response: (Severity: 3), (Category: DRIVER), (Description: The indicated FPD image in IOFPGA bootflash does not appear to have a valid meta-data. This means that a previous FPD upgrade operation did not finish the programming operation of the image.), (Recommended Action: Run again the 'upgrade hw-module location fpd ' command to re-program the image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-6-INSTANCE_ASN_VIRTUAL_NAME ### Response: (Severity: 6), (Category: ROUTING), (Description: The name chosen for the process matches or is a subset of an EIGRP show or clear command. This can cause ambiguities with subsequent show or clear commands for this process. Hexadecimal and octal numbers are not allowed. If Decimal, it should be in range of 1 to 65535.), (Recommended Action: Choose a different name for the process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEPKI-3-KEYAUTOGEN_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: CEPKI keypair autogen error message with two prameters.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_LA_QOS-2-VOQ_FLUSH_FAILED ### Response: (Severity: 2), (Category: QOS), (Description: VOQ Flush failed when applying the drop profile on ingress device.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-PORT_DOWN_WITH_LOCAL_FAULT ### Response: (Severity: 3), (Category: INFRA), (Description: Port is down due to Local Fault.), (Recommended Action: Check for port status, connectivity and note the trigger To recover reset the switch.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_SYSLOG_PRX-3-ERR_LTRACE_INIT ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error. ltrace init failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-MAC_1_TX_FIFO_OFLOW_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: MAC on NPU-1 had transmit fifo overflow on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_PCE-5-PEER_STATE_CHANGE ### Response: (Severity: 5), (Category: ROUTING), (Description: An PCE peer has changed state. This message appears only if the mpls traffic-eng pce logging events peer-status command is configured for the PCE.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KEYCHAIN-3-SYSTEM_MANAGER_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: The 'System Manager' is a central entity which monitors all the processes in any node. It failed to retrieve the requested job id, due to an unexpected error.), (Recommended Action: If the message recurs, issue the commands 'show key chain trace client both' and 'show tech-support sysmgr' to gather required data and contact the Cisco technical support representative with the gathered information and the exact error message as it appears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-3-NULL_HANDLE_MSG ### Response: (Severity: 3), (Category: MGBL), (Description: one of the internal data structure is not valid.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_MA-7-INIT ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_CRP-3-EVENT_MGR_CREATE_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A problem occurred when a call to event_manager_create() was made during the initialization of the candidate-rp.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging | inc err command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging | inc err output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging process autorp_candidate_rp error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging process autorp_candidate_rp error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp candidate-rp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp candidate-rp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show processes autorp_candidate_rp detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes autorp_candidate_rp detail output, call your Cisco technical support representative and provide the representative with the gathered information. From the above command, use the Job ID and try the following command: Copy the error message exactly as it appears on the console or in the system log. Issue the show evm trace jid errors command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show evm trace jid errors output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_HW-3-PARAM_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An incorrect parameter has been passed. This may be due to a software defect, or a wrong parameter passed through command line interface. Please collect the traces.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between the Point-to-Point Three-Way Adjacency TLV and the Three-Way Adjacency TLV in IS-IS? ### Response: The Point-to-Point Three-Way Adjacency TLV is used on point-to-point links to implement three-way handshake for adjacency establishment. It includes the neighbor's system ID and extended circuit ID. The Three-Way Adjacency TLV is used on broadcast links for the same purpose but includes the neighbor's LAN ID instead of the extended circuit ID. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-3-ERROR_WRITE_FILE ### Response: (Severity: 3), (Category: SECURITY), (Description: The system could not insert digest for the file specified in error message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-RX_SECURE_CHANNEL_ESTABLISHED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_NTP-5-LP_CONN_RECOVERED ### Response: (Severity: 5), (Category: IP), (Description: The ntp server recovered a connection with one of the configured clock source. The Stratum tells the change of server stratum.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GE_DMAC-3-OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in GE-DMAC process. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code and a string interpretation of the error code.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers ge-dmac device detail location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers ge-dmac device detail location output, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-6-INSTALL_OPERATIONS_IN_PROGRESS ### Response: (Severity: 6), (Category: INFRA), (Description: Install tasks are in progress, ztp should not abort.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BANNER-7-UNKNOWNCARD ### Response: (Severity: 7), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPGAMGR-2-BOARD_RESTART ### Response: (Severity: 2), (Category: PLATFORM), (Description: The FPGA Manager api for resetting the board via a control register has been called by the process with the specified PID.), (Recommended Action: Collect event logs and any other data specified by the crashing program) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-6-DB_DISK_FREE ### Response: (Severity: 6), (Category: MGBL), (Description: Older commits are deleted to free up some space and unblock any new commits), (Recommended Action: Delete any unnecessary files from the config disk.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DWDM-3-NOT_YET_IMPLEMENTED ### Response: (Severity: 3), (Category: L2), (Description: dwdm, a function was not implemented.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REPLICATOR-7-WRITE_OWNERSHIP ### Response: (Severity: 7), (Category: LIBRARY), (Description: The replicator has failed to acquire ownership of a system data handle.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: Multilink-3-MTU_IMPOSE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The specified MTU could not be applied on this interface.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMITH-3-SYSMGR_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error encountered in initializing system manager.), (Recommended Action: Please collect the 'show logging' output.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_FPGA-1-ERR_HW_RELOAD_NODE ### Response: (Severity: 1), (Category: L2), (Description: A hardware error is detected on the Datapath FPGA. Software will take action as described in the error message to try to recover from the error. The hardware error and the software recovery action will cause linecard reload. Device: %s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Software action: %s - the action that software will take to try to recover from the error.), (Recommended Action: If the message recurs, diagnostics should be executed on the PLIM and MSC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-4-CONFIGURATION_VALIDATION_WARNING ### Response: (Severity: 4), (Category: MGBL), (Description: While scanning running configuration, the Central Configuration Validator (CCV) detected some configuration that violated one or more configuration consistency guidelines. The affected configuration can be inspected using show configuration failed persistent), (Recommended Action: Run the command show configuration failed persistent to display the affected configuration items, together with the resulting warnings. Attempt to resolve the warnings by adjusting configuration as suggested. If you are unable to resolve the warnings or believe the warnings are invalid, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CAIBIST-3-ERR_SW_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Process encountered an error during initialization due to invalid argument, this may be a program level error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-HB_SW_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An internal software error has occurred for the specified SIM Service Engine heartbeat machanism.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-2-MATRIX_CLUSTER_PARITY ### Response: (Severity: 2), (Category: PLATFORM), (Description: A parity error interrupt), (Recommended Action: This error can be corrected by reloading the LC using the command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-3-QUERY_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Unexpected c-shim query failure for given interface handle), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-0-PEX_INT_PORT0_GOOD_BIT ### Response: (Severity: 0), (Category: PLATFORM), (Description: Device driver detected a pex switch error), (Recommended Action: Please try to correct problem by reloading board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_10_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-4-SESSION_SETUP_ERROR ### Response: (Severity: 4), (Category: MGBL), (Description: The RS232 DLL has been unable to setup a session on a TTY), (Recommended Action: Try performing a 'clear line' on the relevent TTY. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-6-DB_COMMIT ### Response: (Severity: 6), (Category: MGBL), (Description: An SDR plane configuration change was made by the specified user.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIAAPI-4-CHAN_CONNECT_FAILED ### Response: (Severity: 4), (Category: MEDIA), (Description: The media server channel specified could not be opened for the specified reason.), (Recommended Action: Report this message to TAC if the messages contine to show up Capture console log, 'show media', show media trace' if message continues) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-3-OIR_TIMEOUT ### Response: (Severity: 3), (Category: MGBL), (Description: This is an error message to indicate that the configuration could not be either saved or restored because of a pending commit operation or commit database consolidation operation. A manual reset of the node after the pending operation has completed should save or restore the configuration for the node.), (Recommended Action: Use the command 'show configuration sessions detail' to verify if the pending operations are still occurring. After the pending commit operation or commit database consolidation operation has completed, use the admin mode command 'hw-module location reload' to reset the node and restore its configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMIO-3-OPERATION_NOTIFY ### Response: (Severity: 3), (Category: PLATFORM), (Description: For notification purpose only.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REPLICATOR-7-BAD_MAGIC ### Response: (Severity: 7), (Category: LIBRARY), (Description: The replicator library discovered a bad magic number in a persistent data structure. This suggests that the data has been corrupted. The replicator library will attempt to recover the situation.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-ADD_SYS_IP_ADDR_ATTR_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error has occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-XIF_GTFF2_MEM_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected XIF GTFF2 memory multi-bit error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2RIB-4-HOST_FROZEN ### Response: (Severity: 4), (Category: L2), (Description: The specified mac or ip address has been detected on more than one host and has been frozen after maxing out the configured number of times it can be detected as duplicate. Please refer to the recommended action to unfreeze the mac.), (Recommended Action: Ensure the mac or ip address is only assigned to one host.The mac-address can be unfrozen using the following cli: clear l2route evpn frozen-mac frozen-flag ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVEDGE_DATA-6-IRL_MAXSLOT ### Response: (Severity: 6), (Category: PLATFORM), (Description: Recommendation for better IRL resiliency), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCCLASS-3-ENS ### Response: (Severity: 3), (Category: MGBL), (Description: One or more ENS or NRS APIs has returned a failure. This failure happens on the producer side.Internal failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTY-3-SYSTEM_LIB_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: A system library call failed unexpectedly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_5_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-6-INFO_SUCCESS ### Response: (Severity: 6), (Category: SECURITY), (Description: The sshd successful login information.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the function of the SNMP in Cisco IOS XR? ### Response: Simple Network Management Protocol (SNMP) in Cisco IOS XR is used for network management and monitoring by querying devices for various statistics and operational data. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_12_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_12 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTY-3-SESSION ### Response: (Severity: 3), (Category: MGBL), (Description: An unexpected error occurred when the VTY Device DLL asked the TTY Server to perform a session operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR* *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-KNOWN_HOG ### Response: (Severity: 6), (Category: HA), (Description: This message is emitted if the top CPU user is known to use substantial CPU under some circumstances.), (Recommended Action: The command 'show watchdog trace' will display additional information about the potential CPU hog. If the hog is persistant, contact technical support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-SHUTDOWN ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process has performed a graceful shutdown and will be restarted.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }'). Check to make sure the process has restarted. If not, restart manually.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_10_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-2-MIGRATE_DONE ### Response: (Severity: 2), (Category: OS), (Description: Migration completed in x seconds.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-6-INIT_LTRACE ### Response: (Severity: 6), (Category: PLATFORM), (Description: The process will continue with it's business, however, as result of this error, mbi-hello will not be able to collect any trace debug information of its operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MACLEARN-3-DLL_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to intialize mac distribution dll.), (Recommended Action: No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-SYSDB_BIND ### Response: (Severity: 3), (Category: SNMP), (Description: SNMP binds to SysDB to receive notifications on the MIB's behalf. MIBs typically use these notifications as triggers to send out SNMP notifications (e.g. Traps). If SNMP cannot bind to SysDB, these SysDB notifications will not be received, and thus some SNMP notifications may never be generated.), (Recommended Action: Check 'show context' command to see if any crash happened and sysdb is in a blocked state. Collect 'show process blocked' and 'run attach_process -p ' output. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-6-INFO_CIDRID_SES_THRESHLD_NO_EXCD ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions on a particular Circuit ID and Remote ID is no longer exceeding the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGMP_MTRACE-3-SOCKET_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: Socket error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information as given in the required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-3-LOOKUP_FAILED ### Response: (Severity: 3), (Category: OS), (Description: The Linux Packet classifier failed to look up information relating to open Linux sockets. This may cause packets which should be handled by Linux applications to get dropped.), (Recommended Action: If the shared memory database being used has become corrupted, this may be resolved by restarting xlncd. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-INCOMPATIBLE_FT_FOR_LC ### Response: (Severity: 3), (Category: PLATFORM), (Description: This LC type is not supported with V1 type Fantray for the ASR9K family as it is not capable to cool down system to required level. There is a risk of damaging hardware by continue running with this type of Fantray Shelf manager raises this alarm when it detects the presence of the incompatible LC and clears the alarm when the LC is no longer seen as being present.), (Recommended Action: Please remove this LC from the chassis and upgrade Fantray to V2. If you have questions, please contact your Cisco technical representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCMCIAD-7-KILL_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Probably the process being killed has already exited), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Check whether the process has already exited with command 'show process all') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-IM_UPDATE_IDB_HANDLE_MISMATCH ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-3-PACKET_TOO_LARGE ### Response: (Severity: 3), (Category: IP), (Description: A packet larger than 4096 bytes has been received, and truncated.), (Recommended Action: The information in required_info to be collected and engineering team to be notified. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-NPU_0_FC_DIP2_ERR_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress flow control DIP2 parity error on NPU-0 interface on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-2-NO_ARB_ACT_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: LC CPU controller driver detected no active arbiter in the system.), (Recommended Action: If there are no RSPs present or if both RSPs are undergoing a reload, then this is an expected message. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FM-3-MALLOC_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Internal error. System is out of memory - malloc failed.), (Recommended Action: Check if there are any possible memory leaks. Memory leaks can be seen using the following commands: - show memory compare start - perform the operation like executing show command/ process restart etc. - show memory compare end. - show memory compare report gives if the process we are looking for is leaking memory. Copy the memory report and error message exactly and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_SYSLOG_PRX-3-ERR_SYSDB_GET ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-7-ERR_TTYMGMT_FD ### Response: (Severity: 7), (Category: SECURITY), (Description: Error encountered while using TTY management library.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-7-OBJECT_INIT_FAIL ### Response: (Severity: 7), (Category: ROUTING), (Description: The policy_repository was atempting to initialize a data object and failed.), (Recommended Action: Look for out of resource conditions. Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-4-ODN_PREFPATH_CONFLICT ### Response: (Severity: 4), (Category: L2), (Description: On Demand Nexthop (ODN) config was attempted for this EVPN VPWS cross-connect. However, there is a pw-class with a static SR-TE policy attached to this cross-connect. As a result, the ODN configuration is ignored.), (Recommended Action: Remove the pw-class under this EVPN VPWS cross-connect to take the ODN configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-IMPLICIT_LICENSE_USED ### Response: (Severity: 4), (Category: LICENSE), (Description: A feature which has no license has been enabled because the system is still in the implicit license period, during which licensed features may be used without licenses. When the implicit license period ends the feature will be deactivated unless a license has been installed.), (Recommended Action: In order to use licensed features, obtain a license and install it using the 'license add' command in admin mode.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-4-ASYNC_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is a message in FIB platform to indicate that engine layer identified an warning while programming an object in h/w.), (Recommended Action: Please collect the console log, show tech-support cef platform. This is not a HW programming error but a warning condition that needs to be monitored for the given table and transition and report any abnormal behavior to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure NTP? ### Response: To configure NTP (Network Time Protocol), use the 'ntp' command in global configuration mode. RP/0/RP0/CPU0:router(config)#ntp server 192.168.1.101 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-6-SUCCESSFUL_HW_AUTHENTICATION ### Response: (Severity: 6), (Category: DRIVER), (Description: Card manager has successfully authenticated Cisco HW genuine check), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-7-ERR_EXIT ### Response: (Severity: 7), (Category: PLATFORM), (Description: An error occurred in Interrupt controller Driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-CHASSIS_POWER_THRESHOLD ### Response: (Severity: 4), (Category: PLATFORM), (Description: Real time power consumption in the chassis (power consumed by all the nodes) has exceeded the threshold of 75% of the worst case available power. Hence the alarm is raised), (Recommended Action: Verify the power draw using CLI: Copy the error message exactly as it appears on the console or in the system log. Issue the (admin)# show env power command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin)# show env power output, call your Cisco technical support representative and provide the representative with the gathered information. Disable power to node consuming more power, using CLI. Copy the error message exactly as it appears on the console or in the system log. Issue the (admin-config)# hw-module power disable location X/Y/Z command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin-config)# hw-module power disable location X/Y/Z output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEMA-4-GEN_ERR ### Response: (Severity: 4), (Category: L2), (Description: An internal error was detected in CEMA module operation), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA_TP-3-ETMM_ATS_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Internal error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DAD-3-SYSDB_BIND_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The bind operation has failed for the above reason. This is something that should not occur under normal operations.), (Recommended Action: restart policy_repository and check for re-occurence of issue) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-OUT_OF_MEMORY ### Response: (Severity: 3), (Category: L2), (Description: The system is low on memory.), (Recommended Action: This indicates a low-memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_9_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-6-MAC_LIMIT_BD_SET ### Response: (Severity: 6), (Category: L2), (Description: Number of MAC addresses in the bridge-domain has reached the configured maximum. If MAC limit action to disable MAC learning and unicast flooding has been configured on the port, then that particular action might have been taken automatically.), (Recommended Action: No particular action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-ABORTTRANS ### Response: (Severity: 4), (Category: MGBL), (Description: An error occurred invoking an MDA function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_HFR-7-ERR_THREAD_MUTEX_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while creating a mutex for use by a client with the specified ID. This is crucial for the process and is automatically restarted on this failure.), (Recommended Action: If the problem is experienced only by this process in the system, restart the fabric server process by executing the following command at the CLI of the active RP: process restart fab_svr location If problem either persists (following a process restart) or also noticed on other processes then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-2-UPGRADE_FPGA_IMAGE ### Response: (Severity: 2), (Category: FABRIC), (Description: FPGA2 version should be minimum 0.33 to operate properly.), (Recommended Action: upgrade hw-module fpd location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-PPS_ACCESS ### Response: (Severity: 4), (Category: L2), (Description: Software could not access the PPS device during initialization.), (Recommended Action: None. Software corrected the issue by power cycling the PPS device.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_IPV6_EA-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Typically, this is an error where the software fails due to failure during forwarding feature programming. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show cef ipv6 location <> show cef ipv6 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPv4-2-MSTATS_ALLOC_ERR ### Response: (Severity: 2), (Category: IP), (Description: Unable to allocated needed stats counters, accounting features may not be working properly.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-CARD_OVERTEMP ### Response: (Severity: 2), (Category: PLATFORM), (Description: Card hotspot temperature has risen at or over critical threshold.), (Recommended Action: Verify the failure, give CLI: (admin)# show env --> particularly temperature and fan output (admin)# show env trace --> to see cards STT values (exec)# show env led details Card can operate in this range but is nearing shutdown temperature threshold (STT).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_CLI-5-WARN ### Response: (Severity: 5), (Category: MGBL), (Description: No error has occurred, but you should be aware that an unusual or unwanted situation may have arisen, and you may want to take preventation action as outlined in the warning message.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND_LITE_MAIN-3-DLL_OPEN_ERR ### Response: (Severity: 3), (Category: L3), (Description: 'Process failed in opening dll.' 'ISSU operation will continue without any error.'), (Recommended Action: 'ISSU manager will retry opening dll after sometime.' 'If the issue persists ,' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-COALESCER_NOT_FOUND ### Response: (Severity: 7), (Category: OS), (Description: A coalesce function name notified from a client is not found), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-2-MIPC_STUCK ### Response: (Severity: 2), (Category: L2), (Description: Inter-processor communcation to the Metro is stuck.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-X86_XFORM_DBG ### Response: (Severity: 7), (Category: HA), (Description: For UT), (Recommended Action: X) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-TSP_A_PKT_FRAME_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: TSP decoder A frame error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_EA-3-AIB_INIT_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The MFR EA process initialization failed whilst trying to connect to AIB. The argument depicts the error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_PFILTER_EA-3-ERR_IM_CAPS ### Response: (Severity: 3), (Category: ACL), (Description: 1) An ACL could not be applied to hardware because of one of the following reasons: a) TCAM max limit has been reached. This error can happen when a new bundle member is added and the ACL can not be programmed successfully. 2) An ACL could not be removed from hardware.), (Recommended Action: 1) When this error occurs the running-config will not be in sync with line card configuration. It is recommended that the bundle member on which the error occured be removed from the bundle. The ACL configuration may also be reduced until it can be successfully programmed on the new bundle member. 2) If the ACL could not be removed from hardware a line card reload is recommended.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDR-3-FIRMWARE_DOWNLOAD_FAILED ### Response: (Severity: 3), (Category: DRIVER), (Description: CDR firmware download failed for the specified slot'), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPMC_GTRIE_DEBUG-3-INIT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error. GTRIE debug library initilization failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM_OFFLOAD-7-INIT_ERR ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: The CFM Software Offload Plugin encountered a fatal error during initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_MQ_SEQ_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue sequence error on XAUI 1 MQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-2-CRIT_MEM_SHUT ### Response: (Severity: 2), (Category: L2), (Description: The system has notified a process that it is critically short of memory and the process is shutting down.), (Recommended Action: Free memory by removing configuration and then start l2vpn_mgr using 'process start l2vpn_mgr'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_AUTO_TUN_MESH_ID_LIMIT_EXCEEDED ### Response: (Severity: 3), (Category: ROUTING), (Description: The creation of the auto-mesh tunnel aborted since all tunnel IDs in the range have already been allocated.), (Recommended Action: Increase the auto-tunnel mesh tunnel range or remove unused auto-mesh tunnels.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-2-PID ### Response: (Severity: 2), (Category: L2), (Description: The PID information is displayed for both supported and unsupported sfp/xfp types for the following actions - OIR of SFP/XFP - Soft and Hard OIR of SPA/LC - unshut of SPA), (Recommended Action: No actions are required as this is just an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-BAGS_UNREG_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to unregister a bag.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-4-FAIL_FILE_IO ### Response: (Severity: 4), (Category: INSTALL), (Description: The Install Helper failed to read/write a file), (Recommended Action: This error occured while copying an MBI file from RP to the DRP disk. This error will be recovered automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ERRDIS-4-EVM_INIT_FAILED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: This is a fatal error. The verification daemon will be unable to process any events. The process will restart in an attempt to clear the error condition.), (Recommended Action: If the error message indicates a potential out of memory condition Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are optional PIEs in IOS XR? ### Response: Optional PIEs are additional packages that provide specific features or functionalities beyond the base IOS XR unicast routing bundle. Examples include PIEs for MPLS, multicast routing, manageability, diagnostics, and documentation. Optional PIEs can be installed on top of the base IOS XR image as needed. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT_SWITCH-3-LINK_FAIL_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: PUNT link has failed.), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-4-EJECTOR_NOT_CLOSED ### Response: (Severity: 4), (Category: PLATFORM), (Description: Card will not power up if the ejector lever is not in close position.), (Recommended Action: Check if ejector is being placed in close position. Try to re-seat the card again if ejector lever cannot be closed properly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPGAMGR-3-SHM_WIN_SETUP ### Response: (Severity: 3), (Category: PLATFORM), (Description: The process was unable to map and configure a shared memory window, causing the process to return unexpectedly. Debugs will provide more info), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-5-SR_POLICY_PM_DELAY_EXCEEDS_THRESHOLD ### Response: (Severity: 5), (Category: OS), (Description: PM delay metric has exceeded threshold specific in the performance-measurement sr-policy delay-profile.), (Recommended Action: None. This is a solicited message (by 'performance-measurement delay-measurement logging delay-exceeded' \ policy configuration) and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_8_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-UNREG_NOT_REG ### Response: (Severity: 3), (Category: HA), (Description: Client is trying to register, which is not even registered.), (Recommended Action: Collect show tech watchdog and show tech sysmgr contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-0-CHASSIS_OVERTEMP_SHUTDOWN ### Response: (Severity: 0), (Category: PLATFORM), (Description: Chassis ambient temperature has risen at or over shutdown temperature threshold (STT). Entire chassis shutdown commencing.), (Recommended Action: No action, this alarm and functionality is deprecated.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCF-7-INIT_LTRACE ### Response: (Severity: 7), (Category: PLATFORM), (Description: This log indicates that SCF server was not able to initialize tracing. As result of this error, SCF server will not have any tracings.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-SEM_CRIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered critical correctable error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_FIB_NPU-3-INT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message in the SSE FIB NPU to indicate that an internal error was seen when trying to check consistency of internal data structures.), (Recommended Action: Please collect the console log, FIB NPU traces (show cef trace loc <>), FIB NPU platform trace (show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ-3-ERR_LWM_FAIL ### Response: (Severity: 3), (Category: L2), (Description: An internal error was detected when trying to send a LWM message. There are several scenarios which can cause this error condition. Error message describes the exact cause.), (Recommended Action: No action is required. The process retries automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-MSG_TYPE ### Response: (Severity: 7), (Category: HA), (Description: A message with an unknown type was received.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_PIDB-3-FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: A run time error occurred during the pidb operation on the linecard. The reason for the error is dispalyed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers sip-pm trace pidb location <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers sip-pm trace pidb location <> output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-IM_RSP_SERCHANNEL_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Rx serdes fault detected/cleared on IM to RSP serchannel), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_IPV6CP_SCAN_IF ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error when scanning for IPv6CP configuration. The error message describes what operation has failed and why it failed. The most likely reason for this is a connection problem with the SubDB service, but the error could also be caused by low memory resources or programming error.), (Recommended Action: Consider restarting the PPP MA process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPU_LTH_FIFO_MBE ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPU packet length FIFO multiple bits error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-ASIC_INIT_FAILURE_SLOT_INST ### Response: (Severity: 3), (Category: FABRIC), (Description: The asic initialization failed due to the above mentioned error.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_7_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does configuration navigation work in IOS XR? ### Response: IOS XR supports hierarchical configuration navigation similar to IOS. You can move between configuration modes using commands like 'interface', 'router', 'line', etc. The 'exit' command moves up one level, while 'root' returns to the top level global configuration mode. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-EVENTBLOCK ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to event block in parser server failed. Parser may exit in this case. The error is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SEIPC-3-OPERATION_FAILURE_STR ### Response: (Severity: 3), (Category: OS), (Description: A critical error during the initialization of Service Engine IPC. The cause of the error will be mentioned in the message displayed. Here is a list of possible reasons for this message (not all-inclusive). - Failed to handle ip addr. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries handle ip address.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-5-DUMP_FAILURE ### Response: (Severity: 5), (Category: OS), (Description: Dumper opens each configured and accessible path and start dumping the core in one of the configured path. If the path is not accessible or invalid or if there is no free space left on the configured path, then core dump might fail, in that case the default path /tmp/dumper should contain the core file.), (Recommended Action: Please ensure that enough free space is present on the configured path(linux command: df -kh . can be used). Collect the following data and contact support. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE0_CODE_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE0_CODE_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ORA-7-DBGINIT ### Response: (Severity: 7), (Category: ROUTING), (Description: The debug event initialization failed. The ora docker will still run correctly, but debug commands may be unavailable.), (Recommended Action: Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-CANT_UNCOMPRESS ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the infrastructure is behaving incorrectly. A file required for carrying out the current request or operation could not be uncompressed, so processing of the operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP transport connection-mode passive feature? ### Response: The BGP transport connection-mode passive feature allows a BGP router to only passively establish TCP connections for a peer, rather than actively attempting connections. The peer must be configured to actively establish the connection. It is configured with the neighbor transport connection-mode passive command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_DLL-3-ERR_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: The CCSQ driver failed to initialize the device resulting in the restart of the CCSQ driver process.), (Recommended Action: Collect all the event logs and the output of the following command executed from the CLI of the active RP: 'show process ccsq_mgr' Also, collect the fabric snapshot: 'show fabric-snapshot file <> loc <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-GROUP_SEND_RINFO ### Response: (Severity: 7), (Category: OS), (Description: When RDS library invoked GSP api group_send_rinfo , it failed.), (Recommended Action: This is a Debug message. No action required. If problem persists,contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are some of the best practices for monitoring and troubleshooting in Cisco IOS XR? ### Response: Some best practices for monitoring and troubleshooting in Cisco IOS XR include regularly checking system logs, monitoring CPU and memory utilization, setting up SNMP for proactive monitoring, using EEM for automated event handling, and leveraging the extensive command-line interface for detailed troubleshooting. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-7-CHKPT_NULL_PTR ### Response: (Severity: 7), (Category: SERVICES), (Description: Failed to do further processing because we got a null data when a non-null value was expected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-LABEL_INCONSISTENCY ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKEND-7-MISMATCH ### Response: (Severity: 7), (Category: SYSDB), (Description: The backend library has detected a mismatch between the actual and parsed values of a node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET_LOOPBACK-3-DEBUG_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize debug in the platform Ethernet loopback component), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-TFTPSERVER_SOCKET_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The opening/binding of the socket for the tftpserver thread might be failing as mentioned in the message. The process will exit and respawn itself.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-3-INVALID_ENV ### Response: (Severity: 3), (Category: INFRA), (Description: Invalid environment variables detected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_MGT_CV_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-1 MGT code violation on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_1_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser temperature greater than or equal to the high temperature alarm threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are BGP peer groups and what are their benefits? ### Response: A BGP peer group is a group of neighbors with the same update policies. Update messages generated for one member of a peer group are replicated for all other members. Benefits include conservation of memory and CPU resources, configuration simplification, and faster convergence. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-UPDATE_COMPLETE ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process unexpectedly failed an attempt to signal to the RIB that the given table is now in sync), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-MISC_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-SPAN_INIT ### Response: (Severity: 4), (Category: PLATFORM), (Description: A failure has occurred while initializing span on the router.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-REPLACE_COMMIT_ALREADY_OP_IN_PROGRESS ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that install commit as part of the replace operation is not attempted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-SIA_INSUFFICIENT_LICENSE ### Response: (Severity: 2), (Category: LICENSE), (Description: Number of SIA license(s) used is more than available. Software upgrades will be blocked once the SIA grace period of 90 days expires. Please check show license platform summary/detail for more information.), (Recommended Action: The customer should deposit the required SIA licenses in the virtual account.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-GETPIDFAIL ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: Packet Server failed to get the client's pid. This will prevent the client from connecting to packet server.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-5-SC_UNPACKTUP ### Response: (Severity: 5), (Category: SYSDB), (Description: The packed tuple returned from SysDB is in some way corrupt. The data it contains could not be read.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-7-ASYNC_MSG_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Received unexpected async message type.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.=) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-NH_DB_ADD ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occured when trying to clear redist information for a client.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_RIB-3-ERR_PATH_DELETE ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered in the call to ipv6_rib_batch_delete_path.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDS_DB-3-MUTEX_LOCK ### Response: (Severity: 3), (Category: OS), (Description: Failed to lock the mutex.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-MPLS_LABEL_BLK_RW_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Service-layer could not program the label in Label Switching Database.), (Recommended Action: Programming for label block failed in Label Switching Database. This can occur if label block parameters do not match with other allocated or configured label blocks in the system. Correct the system configuration to free up label block being programmed through Service layer. Look at Service Layer traces and show commands for more information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-MIBINSTALL ### Response: (Severity: 4), (Category: SNMP), (Description: An error was encountered during installation of a new MIB or deletion of an old MIB. These messages are printed when MIB installation/deletion failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-THREAD_CREATE_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Event Thread creation failed.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists.' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_FIFO-7-DEBUG_INIT_ERROR ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MOTHRA-3-FATAL_ERROR ### Response: (Severity: 3), (Category: L2), (Description: A fatal error occurred in mothra Driver which involves exiting the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-X86_XFORM_AFTER ### Response: (Severity: 7), (Category: HA), (Description: To print the values after conversion.), (Recommended Action: X) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the mutex synchronization mechanism? ### Response: A mutex (mutual exclusion) lock is used to protect shared data. Before accessing the data, a thread must acquire the mutex. This blocks other threads from accessing the data simultaneously. When the thread is done, it releases the mutex, allowing other threads to acquire it. This prevents race conditions and data corruption. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-POWERRELOAD_RESET ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that the node is being reloaded because of a critical environmental alarm.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-7-RIB_TABLE_INFO ### Response: (Severity: 7), (Category: ROUTING), (Description: A warning was encountered during some operation for the specified address family and RIB table. This could be due a software timing issue, caused by configuration changes.), (Recommended Action: This behaviour is expected, if the table has just been unconfigured. No action is needed unless there are any operational problems.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_11_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_11 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-6-LOW_FAN_SPEED_WARNING ### Response: (Severity: 6), (Category: PLATFORM), (Description: Informational msg indicating that the fan is spinning very slow.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM_POLICY-3-ORA_ORABUILD ### Response: (Severity: 3), (Category: ROUTING), (Description: There was an internal error in the routing policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-MUTEX_INIT ### Response: (Severity: 3), (Category: OS), (Description: PlaceD daemon was unable to initialize the internal state mutex. Recovery occurs with automatic process restart.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key platforms that currently run Cisco IOS XR? ### Response: The main platforms running IOS XR are the Cisco CRS-1 and CRS-3 carrier routing systems, Cisco 12000 series routers, and Cisco ASR 9000 series aggregation services routers. IOS XR is designed for distributed, carrier-class routing platforms. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_APS-6-CONFLICT ### Response: (Severity: 6), (Category: L2), (Description: A conflict failure occured The message contains info about the cause of the failure and possibly anticipated actions/effects.), (Recommended Action: Fix the confguration error for proper operation of SONET APS.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-IN_BUF_CRC_ERROR_LNK4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected excessive input buffer CRC error on link 4), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. Also, check for any damage to the card and its backplane connectors. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-PD_MINI_REMOVAL_AFTER_SU ### Response: (Severity: 4), (Category: INSTALL), (Description: Due to lower disk space platform opted for mini iso removal post system upgrade), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-4-FAILED_SDS_CONNECT ### Response: (Severity: 4), (Category: INSTALL), (Description: A node was unable to connect to a Software Download Server and will try to directly connect to the Install Director on the dSC as a result. This may be due to a failure in updating the LRd inventory following a change in the state of an SDS. The install operation should download software directly from the dSC and should not be impacted. However, if many nodes attempt to get software directly from instdir other processes may be impacted by high CPU usage.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR support in-service software upgrades (ISSU)? ### Response: Cisco IOS XR supports ISSU by allowing software upgrades without interrupting the router's operation, ensuring continuous network service during the upgrade process. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-6-KERNEL_DUMP_MSG ### Response: (Severity: 6), (Category: IP), (Description: A kernel dump started/finished to the file as mentioned in the message from a remote node via TFTP.), (Recommended Action: This is an informational message. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RAW-3-TIMER_INIT ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the RAW process sets up and initializes the various RAW timers.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to roll back to a previous configuration in Cisco IOS XR? ### Response: To roll back to a previous configuration, use the 'rollback configuration' command in global configuration mode. RP/0/RSP0/CPU0:router#config RP/0/RSP0/CPU0:router(config)#rollback configuration last 1 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: PLATFORM), (Description: The dsc process could not allocate memory. This indicates some problem with the system wide memory.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the dsc process is up and running by executing the following command at the CLI of the active RP: 'show process dsc' If it is still non-operational, restart the driver by executing the following command at the CLI of the active RP: 'process restart dsc' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_INARP-3-INVALID_FD ### Response: (Severity: 3), (Category: L2), (Description: An event was received with an unknown fd), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-2-ADDROUTE ### Response: (Severity: 2), (Category: ROUTING), (Description: An error occurred whilst trying to insert a net to the BGP table database.), (Recommended Action: 'This error occurs when we are not able to add a net to the BGP table' 'database. In some cases the nbr that had sent that net would reset ' ' and the issue would recover. In other cases you might see an ' 'accompanying low memory message. Please check to make sure you have ' 'enough free/available memory on the router. ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'af-group' in IOS XR BGP configuration? ### Response: An af-group allows the definition of common address-family (AF) specific configuration parameters that can be inherited by multiple neighbors for a given AF. This simplifies configuration when many neighbors require the same AF configuration. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-4-WARM_RESET_FAILED ### Response: (Severity: 4), (Category: L2), (Description: This is an error message in the NPU Driver to indicate that it failed to perform warm reset of specified NPU instance due to the specified reason.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BPE-7-ERR_EVM_NOTIFY ### Response: (Severity: 7), (Category: PLATFORM), (Description: BPE Event Manager notify error), (Recommended Action: Please attempt to correct the error by restarting the process by issuing the command in exec mode -process restart bpe If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_DLL-2-DEVICE_HALT ### Response: (Severity: 2), (Category: FABRIC), (Description: CCSQ, ASIC got halted. The halted block and its parent block are provided), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWRMON-2-MODULE_FAILURE ### Response: (Severity: 2), (Category: PLATFORM), (Description: 'Either an internal PEM error, an over voltage/current/temperature shutdown or an external input feed error.'), (Recommended Action: Try restarting the using CLI command in exec mode - process restart pwr_mgmt If the error exists try -insert and re-insert the PM If the error exists - Replace the power module) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_FADB_MAIN-3-SYNC_HDLR_ATTACH_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB FADB encountered an error while attempting to attach sync event handler for process fsdb_fadb), (Recommended Action: Search the event logs for events/errors related to the failure reason. Event management is part of overall system. If there are failures here then other processes may also exhibit similar problems. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-6-UPGRADING ### Response: (Severity: 6), (Category: MEDIA), (Description: Regular nvram: file system is in upgrading process), (Recommended Action: Nothing needs to be done) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_WL_OUT_OF_RANGE ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-3-ERR_INVALID_GROUP ### Response: (Severity: 3), (Category: SECURITY), (Description: AAA failed to recognize the specified server group name. It may be undefined.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-3-MPA_UNSUPPORTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: This MPA does not supported in this system. Please check with Cisco tech team for more informtion.), (Recommended Action: Remove it from the system or migrate to software which supports it. Alternatively unsupported MPA can be shutdown using CLI '(config)#hw-module subslot <> shutdown') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_ASR9K_LIB-3-FAILURE_TO_CACHE_FILE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The platform library service call to failed to cache the file contents of the Board's EMT file), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_7_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-4-MPA_OPTICS_OVERTEMP_FAULT ### Response: (Severity: 4), (Category: PLATFORM), (Description: Over Temp Fault Observed for Optics and Optics will go to Fault State. Please check with Cisco tech team for more informtion.), (Recommended Action: Do the Optics OIR or MPA reload to recover the Optics from Fault state. If the issue occurs under other conditions, then copy the error message exactly as it appears on the screen and collect console log and the following information. Contact your technical support representative with the gathered information. - sh platform - sh install summary - sh version - show tech-support ethernet interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD_NETIO_DLL-3-INVALID_PORT ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Forwarder was supplied with a plim port or uidb index that exceeds the limit of num ports.), (Recommended Action: No Action required Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-RX_ALARM_FRAME_ERR_SYNC_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: For UTI mode alarm is raised if frame error rate exceeds 2%.), (Recommended Action: 1) Ensure valid BITS/UTI signal is applied at input port.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_OUT_MEM_UCORR_ECC_ERROR_LNK1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast output memory uncorrectable ECC error on link 1), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-MAINT_IMG_NOT_FOUND ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Maintenance Image could not be located in the indicated path.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-4-ERR_PACKET_INVALID_MSTI ### Response: (Severity: 4), (Category: L2), (Description: A packet has been received referencing an unknown MSTI, despite the packet being viewed as internal. This probably indicates an inconsistency on the other end.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTDIR_INVENTORY-7-NULL_PTR ### Response: (Severity: 7), (Category: INSTALL), (Description: A client of the Install infrastructure passed a NULL pointer. The current request or operation may not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-4-MARTIAN_SOURCE ### Response: (Severity: 4), (Category: ROUTING), (Description: Ignoring sa cache creation for Martian source.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_Manager-3-UPGRADE_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: Update FPD upgrade ERROR), (Recommended Action: Customer immediately knows the reason of failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-3-COID_MISMATCH ### Response: (Severity: 3), (Category: OS), (Description: coid does not match with the ethernet server coid (server_coid) %d- coid %d- server coid), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_EVM_CONN_NOTIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-1-BACKUP_NOT_READY ### Response: (Severity: 1), (Category: HA), (Description: RMF has determined that the backup process groups are NOT ready because of the failure of one or more events the prevent it from being in-sync with the primary process groups.), (Recommended Action: Use show redundancy to see not ready reason. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-DECODESTR ### Response: (Severity: 3), (Category: MGBL), (Description: 'The sysdb decode operation failed. The error message is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-INVALIDVERSION ### Response: (Severity: 3), (Category: MGBL), (Description: 'The version of this file is too old or wrong'.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_GENERAL ### Response: (Severity: 3), (Category: SECURITY), (Description: SSH encounterd some error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-2-HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected an SFP temperature greater than or equal to the high temperature alarm threshold. The SFP is the pluggable optics on the line cards. The temperature threshold values are read from the SFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational, and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-XAUI_0_FRAG_ERR_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: XAUI interface to NPU-0 reported fragmentation error on TX side on bridge instance - 2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPIO-3-CLUSTER_OFFLOAD_NOT_SUPPORTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: CFM is configured over bundle interfaces with bundle members configured on standby DSC of cluster. Bundle offload is globally configured. Bundle offload is only supported on line cards on the primary DSC.), (Recommended Action: Either disable the bundle offload globally or remove the bundle members from line cards on the secondary DSC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBCORE-3-EVM_CREATE_ERR ### Response: (Severity: 3), (Category: SNMP), (Description: The creation of socket with event manager failed due to some reason. The argument depicts the reason of the failure.), (Recommended Action: Copy the message exactly as it appears, and report it to your technical support representative with required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option explicit feature? ### Response: The MPLS TE path-option explicit feature allows the path for an MPLS TE tunnel to be explicitly specified using a configured path. An explicit path is a list of IP addresses or interface names that define the tunnel's route. Explicit path-options override dynamic path calculation and provide exact control over the tunnel's path. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-SOCKET_WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: The specified socket operation failed.), (Recommended Action: Such errors are possible during raw_ip restarts. If seen otherwise, these errors should be reported to SUPPORT.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-3-LINK_RESET_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An attempt to reset the PCIe link has failed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_MAP-3-EVENT_MGR_CREATE_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A problem occurred while calling the event_manager_create() API during the initialization of the mapping-agent.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging | inc err command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging | inc err output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging process autorp_map_agent error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging process autorp_map_agent error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp mapping-agent trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp mapping-agent trace output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSEC_SVI_EA-3-INTERNAL_ERR ### Response: (Severity: 3), (Category: SERVICES), (Description: An unexpected internal error has occurred in the IPSec SVI EA process. The process will restart.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-5-PARTITION_REASON ### Response: (Severity: 5), (Category: MEDIA), (Description: The media storage card specified is going to be (un)partitioned due to the specified reason.), (Recommended Action: Restore any lost data on device due to partition table update and formatting of all partitions.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_MALLOC_LEN ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error. System is out of memory - malloc failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTIO-6-NO_PORTS ### Response: (Severity: 6), (Category: L2), (Description: The VTIO SPP plug-in found no ports to manage. No packets will be sent/received in SPP (except fabric loopback packets) on this node.), (Recommended Action: If any problems are seen, they may be rectified by ensuring that the specified topology file contains interfaces for the current node and rebooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-SDWRAP_ERR ### Response: (Severity: 3), (Category: OS), (Description: Debug infrastructure error.), (Recommended Action: Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-3-ERR_SYSDB_UNPACK ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_3_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-DEV_CFP_PID_NOT_SUPPORTED ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PID not supported error was detected during CFP initialization. A PID not support error is reported when either the PID can not be read it not supported on the platform. The CFP is the pluggable optics on the line cards. CFP initialization may happen when linecard boots up, CFP OIR and line card process restart. Traffic will not be impacted by this error.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp router-id' command in IOS XR BGP configuration? ### Response: The 'bgp router-id' command is used to manually configure the BGP router ID. By default, the BGP router ID is chosen as the highest IP address configured on a loopback interface. If no loopback interface is configured, the highest IP address from the physical interfaces is chosen. Manually configuring the router ID provides stability in case of interface flaps. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPPIF-2-INIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: A run time error occurred while initializing the lc idb on the linecard. The reason for the error is dispalyed. Please call Cisco Support with the error information), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBUS-7-API_INFO_DUMP ### Response: (Severity: 7), (Category: PLATFORM), (Description: Displaying mbus API debug information. The argument indicates information message to be displayed), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYNCFS2-7-LRD_NOTAVAILABLE ### Response: (Severity: 7), (Category: MEDIA), (Description: The Standby card has been either removed or put down by admin), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_LOCAL-5-AIS_PWFAULT ### Response: (Severity: 5), (Category: L2), (Description: L-AIS insertion/removal notification messages.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_NTP_LIB-7-EXIT_MESSAGE ### Response: (Severity: 7), (Category: IP), (Description: NTP process exits and restarts when it detects a failure. If the error does not persist it can be ignored.), (Recommended Action: None required if NTP process restarts and recovers.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGMP_MTRACE-3-EVENT_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: Event error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information as given in the required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-FSM_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Shelfmgr failed to inject the given event into the FSM for the given node.), (Recommended Action: Restart shelfmgr process on active RP. If problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-ERR_INTERNAL_SW ### Response: (Severity: 3), (Category: FABRIC), (Description: The 140G fabric POD DLL encountered the annunciated internal SW error. It likely affects the operation of the fabric POD and the fabric subsystem on the multi-chassis.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-4-FI_LINK_BRINGDOWN ### Response: (Severity: 4), (Category: FABRIC), (Description: A fabric link was brought down due to too many UCE or parity errors.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DATABASE-4-TRACE ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This is a non-fatal error and can happen when router is low on memory. It should not affect the functioning of the router, but trace messages may not be logged.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-CONFIG_DOWNLOAD_STARTED ### Response: (Severity: 6), (Category: SERVICES), (Description: 'Config download is triggerred'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ct_agent-3-ERR_ERRNO ### Response: (Severity: 3), (Category: SECURITY), (Description: Error description, error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-ERR_SECURITY_TTL_OPT ### Response: (Severity: 4), (Category: OS), (Description: security ttl feature is not effective. As OPSF protocol entries being optimized in TCAM, enabling this feature on selective OSPF neighbors is not permitted), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard for security ttl to be effective. Other options is to reload the linecard. Or remove and re-apply the interface configs in ospf.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_8_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-LOOPBACK_CANCEL ### Response: (Severity: 6), (Category: L2), (Description: An attempt has been made to start loopback mode from both peers simultaneously. As per the IEEE 802.3 OAM specification, this OAM client has cancelled the request as the local MAC address is lower than the remote MAC address.), (Recommended Action: Retry the Loopback operation from this peer once the remote loopback session on the remote peer has been terminated.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPC-2-HW_ERR ### Response: (Severity: 2), (Category: MGBL), (Description: Data plane HW error interrupt occurs.), (Recommended Action: Check if the DPA reported any other errors and/or traffic loss was observed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-PRESHARED_KEY_NOT_FOUND ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to find pre-shared key.), (Recommended Action: 'Contact administrator') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LAMPTEST-6-COMPLETE ### Response: (Severity: 6), (Category: PLATFORM), (Description: Test of all system LEDs has now finished.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-PHY_FPGA_SERCHANNEL_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Transmit serdes signal issue detected/cleared between PHY and FPGA.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_PROXY-3-ERR_CONN_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: The fabric proxy failed to connect to the required services. The driver will be non-operational due to this error.), (Recommended Action: The Proxy will recover by restarting. Verify that the fabric proxy process will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_ECSR_1 ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an eCSR1 access error.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-SIA_LICENSE_TERM_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The term of the SIA license has expired.), (Recommended Action: The customer should reserve a valid license.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-3-EAOPT_KEYMAX ### Response: (Severity: 3), (Category: IP), (Description: TCP Enhanced Authentication header has 6 bits for the keyid, hence, the send key can't be more than 63.), (Recommended Action: Change the keychain configuration to not have a key-id greater than 63. No need to re-configure it under BGP or to clear BGP neighbors.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-3-PA_CONN_FAIL ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to open a client connection to PA.), (Recommended Action: Restarting the client may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_LQ_PKT_LEN_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue packet length error on XAUI 0 LQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are some of the major functionality areas included in the composite .vm bootable file? ### Response: The composite .vm bootable file contains the following major functionality areas: operating system kernel, base image, admin plane features, and routing and forwarding bundles. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-3-INVALID_PORT ### Response: (Severity: 3), (Category: IP), (Description: 'The port specified on the command line can not be converted'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED_LIB-3-PLATFORM_GET_ERROR ### Response: (Severity: 3), (Category: OS), (Description: A placed client API failed in the call to platform api to get its nodeid or node name. Its an issue with platform call.), (Recommended Action: Collect the function name and traceback information in addition to the below show commands and forward to your next level of technical support. show commands: show tech placed, show tech sysmgr, show redundancy summary, show redundancy trace) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKWATCH-6-TRACEBACK ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The traceback info about caller), (Recommended Action: It is an informational message along with packet depletion log message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM_CLIB-3-TLV_DECODE_ERROR ### Response: (Severity: 3), (Category: IP), (Description: This is an internal error. It indicates that an address information structure couldn't be decoded correctly. This could leave the affected process in an inconsistent state.), (Recommended Action: Get the output of show tech-support, show arm [ipv4/ipv6] trace, running coredump of the process. Unconfiguring, reconfiguring the interface may help in recovering the from error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-PCI_MAP_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-0-INIT_FAILURE ### Response: (Severity: 0), (Category: MGBL), (Description: An error was encountered while initializing one of the critical modules of the tacacsd. Without proper initialization of this module, tacacsd can not operate properly. Initialization will be retried.), (Recommended Action: tacacsd is a critical component and must be operational in order to configure the router. If the same error is seen more than 5 times, contact Cisco TAC support because a reboot of the node may be required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFI_EA-4-RETRY ### Response: (Severity: 4), (Category: L2), (Description: The SFI EA process has retried programming SFI interface(s) because other processes are not ready.), (Recommended Action: If the retry does not succeeded in some time, remove and re-create the SFI Interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PVSTAG-4-VLAN_INSTANCE_LIMIT ### Response: (Severity: 4), (Category: L2), (Description: The supported number of PVRST or PVSTAG VLAN instances on this line card has been exceeded, or has been brought back under the limit. When the limit has been exceeded, PVRST or PVSTAG may not operate correctly or there may be an adverse performance or scalability impact on the rest of the system.), (Recommended Action: Unconfigure some VLAN instances until the total number configured for interfaces on this line card is beneath the limit.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-7-CERR_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the cerrno module in the platform L2FIB component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP graceful restart feature? ### Response: BGP graceful restart is used to preserve the forwarding state when a BGP session goes down, allowing traffic to continue to flow while the control plane restarts. It requires the graceful restart capability to be exchanged when the session is established. It is enabled with the bgp graceful-restart command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LINK-5-DAMPENING ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: The interface dampening state changed. When the state is 'suppressed' the interface will be held down. In 'unsuppressed' state, link state changes are allowed to occur as normal.), (Recommended Action: If the dampening state change was unexpected, confirm the configuration settings for the interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install rollback command in IOS XR? ### Response: The 'install rollback' command is used to revert the system back to the previously committed software set. This is useful if issues are encountered after performing an installation or upgrade. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_DISC-3-PARTICLE_HUGE_POOL_DEFINE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Define particle pools over memory regions. If there is not enough space to hold all the particles, less particles will be created. Each pool can have its own particle size. Particle defined as Huge pool got failed.), (Recommended Action: Copy the System Message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-EVENTMGRCREATE ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to create parser event manager failed. The error is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-MEMORY_RECOVERY_KILL_SYSMGR ### Response: (Severity: 6), (Category: HA), (Description: The sysmgr process with the indicated name and pid has been killed in an attempt to recover system memory. The process can be manually restarted if desired, but may continue to consume large amounts of memory.), (Recommended Action: The system is critically short of memory. Automatic recovery will attempt to stabilize the system, but there is either a memory leak or a misconfiguration. Both require operator intervention.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCMCIAD-7-UNLINK_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: PCMCIAD failed to unlink instance of child file name shown), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture console log and dumpcore of process pcmciad.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP maximum neighbor feature? ### Response: The BGP maximum neighbor feature allows a limit to be placed on the number of dynamic neighbor connections that can be established as a result of the BGP dynamic neighbor feature. It protects against resource exhaustion. It is configured with the bgp max-neighbors command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FILECOPY-3-EVMCREATE ### Response: (Severity: 3), (Category: OS), (Description: The filecopy_process was unable to create an event manager. The filecopy_process will shut down since it cannot receive any events. Try restarting the process - if the error continues, contact customer support with the error message and associated context.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GT_ETH_MGMT-3-EVM_CREATION_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error detected when creating the event manager. process will restart automatically to recover from this error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ET0_INTR_CRC32_CHK_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ET0_INTR_CRC32_CHK_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_LOCKING_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An unxpected error occured while trying to lock or unlock an IS-IS resource. This implies an internal software programming error.), (Recommended Action: Consider restarting the IS-IS process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCASTSN-5-DP_CONGESTION_CLEAR ### Response: (Severity: 5), (Category: L2), (Description: The layer 2 multicast data plane hardware programming has been resynced with the state in the IGMP snooping application.), (Recommended Action: The system is attempting to recover from a layer 2 multicast data plane programming congestion condition. No user action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-ERR_SYSDB_API ### Response: (Severity: 3), (Category: MGBL), (Description: 'Unable to perform a sysdb api call. The module which is calling this api, the description of the api and the error is displyed in the error message.'), (Recommended Action: collect show parser trace, show logging, any abnormal console message, and configuration of the router. Then send this output to tech support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ce_iso-2-FAULTCE_DISABLEPORT54_55 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fault detected while disabling the port because of the failure of disabling functionality. Isolating RP node from the CE network is failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SD-3-INIT_FAILED ### Response: (Severity: 3), (Category: SERVICES), (Description: The Service Director has failed to start up. The operation being attempted is detailed in the error message. The Service Director will be restarted automatically.), (Recommended Action: If the error indicates an Out Of Memory error, then attempt to increase the available resources. Otherwise, if the error persists, contact your technical support representative copying the error message exactly as it appears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAAD-3-ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: An error was encountered. The failure of this is not critical to aaad but may have significant impact to general system operation.), (Recommended Action: If the error persists, copy the error message and trace exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-5-ADJCHANGE ### Response: (Severity: 5), (Category: ROUTING), (Description: Adjacency to SYSTEM-ID (INTERFACE-NAME) Up|Down, REASON. The adjacency to the system with SYSTEM-ID has gone up or down due to REASON.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-UNKNOWN_BOARD ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the board type cannot be recognized, therefore, the node will not be able to boot up. This usually caused by an invalid eeprom content.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACE_LC-6-ACE_SYSLOG_INFO ### Response: (Severity: 6), (Category: SECURITY), (Description: ACE SPA SYSLOG message), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-3-ECM_CREATE_FAIL ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to create event connection manager.), (Recommended Action: The process would recover itself from this error as there is a retry mechanism. If the error is still seen restarting the clients may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-DEQUEUEFAIL ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: Packet server failed to remove the specified client from the client list queue. This may cause the client fail to reconnect to packet server.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-RPF_REDIRECT_SN_THRESHOLD ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-3-ASYNC_LISTEN_CLOSE_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The socket library has noticed an attempt to close an ASYNC listen socket in error. This could place the system in an inconsistent state. The message may be ignored, if it was seen when a TCP application crashed or was either restarted or shut.), (Recommended Action: If not seen during a process restart of tcp, please collect the required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-4-WRONG_KEY ### Response: (Severity: 4), (Category: SECURITY), (Description: Tacacs+ server key configured on the router is wrong.), (Recommended Action: Please configure correct key on the router for the tacacs+ server.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR-3-MA_SHUTDOWN ### Response: (Severity: 3), (Category: FORWARDING), (Description: This messages indicates that a failure has occured while PBR is gracefully shutting down. Particular reason is included in the message.), (Recommended Action: Allow PBR MA to exit and validate with the command show process pbr_ma location . If it does not exit, use process restart pbr_ma location to recover. If the problem persists, contact Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-4-TOP_MEMORY_USERS_WARNING ### Response: (Severity: 4), (Category: HA), (Description: This message is emitted when system memory usage crosses a threshold in the direction of increasing memory exhaustion. The top memory users will follow in the next messages. There may be a memory leak or misconfiguration.), (Recommended Action: Collect the data from the following messages and attempt to determine what is driving memory usage. Forward the messages to technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-6-LICENSE_CLEAR_FEATURE ### Response: (Severity: 6), (Category: LICENSE), (Description: As a result of 'clear license' command execution, license features installed on this system were cleared.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-IDPROM_READ_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: The read of the one_wire prom for the given slot has failed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SE_P2MP_SRVR-3-EVM_EVENT_BLOCK_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in the event loop. p2mp server process will exit.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GDOI-6-SVC_INFO ### Response: (Severity: 6), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-SA_NOT_AUTH ### Response: (Severity: 3), (Category: SECURITY), (Description: The IKE security association with the remote peer was not authenticated; yet the peer attempted to begin a Quick Mode exchange. This exchange must only be done with an authenticated security association.), (Recommended Action: 'Contact remote peer's administrator.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO_COMMON-4-VERIFY_CLEANUP_FAILED ### Response: (Severity: 4), (Category: L2), (Description: Whilst exiting, an error was encountered cleaning up a common module. The process will exit anyway, and no further errors should be seen.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-FSMTIMEOUTD_RESET ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is not able to boot up. If an XR-hello is not recieved within a specified time limit, then the node will go to ENA-FAILURE.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-INVALID_ID ### Response: (Severity: 3), (Category: OS), (Description: Shmwin server detected invalid window ID or group ID in shmwin meta data.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture meta data file /etc/platform_shmwin, 'show version', and 'show shmwin trace server' output) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KEYCHAIN-3-SYSDB_ERROR_INIT ### Response: (Severity: 3), (Category: SECURITY), (Description: The SysDB (System Database) is a system registry which stores the system state information as well as the process-specific information. A problem occurred so that the connection to this system database could not be established.), (Recommended Action: Restarting the keychain server process (kc_srvr) with the command 'process restart kc_srvr' might solve the issue. If the message recurs, issue the following command 'show tech-support sysdb' and 'show key chain trace client both' to gather data and provide the gathered information and the exact error message as it appears, to the Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-4-INVALID_MTU ### Response: (Severity: 4), (Category: IP), (Description: Minimum IPv6 MTU must be 1280. Available ipv6 mtu is not within the valid range.), (Recommended Action: Adjust the lower layer mtu such that atleast 1280 bytes is available to ipv6.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-3-CLIENT_START_DATA_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to get client start data.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-3-PM_INIT_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The SLA Profile Manager failed to initialize correctly, and will now exit. It should be restarted by SysMgr.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_RP-3-DEBUG_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB (D)RP component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTP4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PREF_COMPR_LIB-6-V6_CMPR_FAILED ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: V6 source prefix compression failed due to lack of extended path. This failure indicates that a particular v6 prefix indicated in the message will not be compressed. There are 3 workarounds of this problem. 1) do not use this entry. 2) change the prefix length. 3) change the prefix value. For example if an entry failed. 4) use the compression anchor prefix cli controller sse tcam location R/S/I compression ipv6 anchor-prefix to configure the common IPv6 prefix lengths during an ACL programming then try removing that ACE indicated in the message and apply the configuration again. *DDTS*), (Recommended Action: Ouput generated by this message and related config, for example v6 ACL failed in case of ACL configuration. Attach them to the ddts. This failure indicates that a particular v6 prefix indicated in the message will not be compressed. There are 3 workarounds of this problem. 1) do not use this entry. 2) change the prefix length. 3) change the prefix value. For example if an entry failed during an ACL programming then try removing that ACE indicated in the message and apply the configuration again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OT-3-ERROR ### Response: (Severity: 3), (Category: SERVICES), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_7_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FURIA_LIB-3-CDR_REPEATER_MODE_RECFG ### Response: (Severity: 3), (Category: PLATFORM), (Description: CDR Repeater Mode Status), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTY-3-DB ### Response: (Severity: 3), (Category: MGBL), (Description: An unexpected error occurred whilst the VTY Device DLL was using the TTY DB library.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR* *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_XRV9K-3-ERR_LTRACE ### Response: (Severity: 3), (Category: L2), (Description: BFD PLAT was unable to initialize the tracing services. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: Collect all the event logs and the output of following command executed from the CLI: 'show process bfd_agent location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCONBKUP-7-REPLY_ERR ### Response: (Severity: 7), (Category: MGBL), (Description: Error encountered while replying message during ASCII System Configuration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure MPLS L3VPN VRF selection based on source IP? ### Response: To configure MPLS L3VPN VRF selection based on source IP, use the 'vrf select source-ip' command in global configuration mode. vrf select source-ip vrf MyVRF <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-ERR_DRV_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: SFE driver failed initialization due to the above reason), (Recommended Action: The driver will restart and try to recover. Make sure the driver restarts and recovers. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_CFEC_AIS_DEM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-PLL_T4_STATE_FREERUN ### Response: (Severity: 3), (Category: PLATFORM), (Description: No external reference frequency is available for synchronization, so the T4 PLL output is free-running.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_EVC_EVM_HANDLER ### Response: (Severity: 4), (Category: L2), (Description: During initialization, SSRP failed to register for input or output notifications for the specified service. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGPTE_LIB-4-SERVER_ERR_CLINFO_UNHOLD ### Response: (Severity: 4), (Category: ROUTING), (Description: IGP failed to release its client's message channel information. This could be a result of channel down already.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_CLI-3-MEMORY ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP CLI Agent was unable to allocate the required amount of memory, as the HTTP process has run out of resources. The HTTP process may no longer be able to function correctly, and may need restarting if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_SYSDB_UNREG_NOTIFY ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to unregister for notification of changes on the displayed SysDB path. The error will not affect IS-IS operation but does indicate unexpected system behavior.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-HOST_SLAVE_QUEUE_FULL ### Response: (Severity: 3), (Category: PLATFORM), (Description: NP detects HOST_SLAVE_QUEUE_FULL and reported through interrupts), (Recommended Action: No specific actions needed. The software should be able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LICENSE-6-ENFORCE_METERED_USAGE ### Response: (Severity: 6), (Category: LICENSE), (Description: Smart Licensing is enabled with the metered billing method.), (Recommended Action: 'INFO') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can a default route be originated in BGP? ### Response: A default route can be originated in BGP in two ways\n1) Using the default-information originate command, which will originate a default if one exists in the routing table.\n2) Using the neighbor default-originate command, which will originate a default to a specific neighbor unconditionally.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-SA_NOT_OFFERED ### Response: (Severity: 3), (Category: SECURITY), (Description: IKE found SA not offered), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-PCI_RAM_UNCORRECTABLE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Indicates an uncorrectable multi-bit error occurred on this internal SRAM. %s - name of ram that error occurred %x - key of error node recorded %s - error data), (Recommended Action: Ignore the message if appears only once. Otherwise reload the board Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-FBU3_LOW_RESOURCE ### Response: (Severity: 3), (Category: PLATFORM), (Description: NP detects FBU3_LOW_RESOURCE and reported through interrupts), (Recommended Action: No specific actions needed. The software should be able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-INSTALL_UNREG ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred when trying to unregister with the packaging subsystem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-INT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message in the OFA FIB to indicate that an internal error was seen when trying to check consistency of internal data structures.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-6-MBI_BOOTING_HOLD_BOOT_IN_MBI ### Response: (Severity: 6), (Category: INSTALL), (Description: Nodes can not boot up while the platform determines that they have to be held in MBI. Once the platform lifts the hold then the node will be allowed to complete its boot as normal. recommended_action: *NONE*), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-KDUMP_DONE ### Response: (Severity: 3), (Category: PLATFORM), (Description: OS running on the indicated card is reporting kdump has ended.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NLMMIB-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: SNMP), (Description: The requested operation could not be performed due to a low memory condition.), (Recommended Action: 'Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-3-ERR_FGID_DOWNLOAD_FAILED ### Response: (Severity: 3), (Category: FABRIC), (Description: The message is seen when initial FGID download from the FGID server to SFE driver does not get completed even after multiple attempts to reset the EES connection. This means the communication between SFE driver and FGID driver is broken and indicates a EES transport issue.), (Recommended Action: Capture the output of the CLIs as specified in required_info and contact your Cisco technical support representative. Once the required information is captured, a restart of sfe_drvr process on the affected fabric card, followed by a restart of fgid_server process on the appropriate RP/DRP can be attempted to recover from this error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-SAME_SID_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message in the OFA FIB to indicate that same sid label is used for L2-Adj-Sid and L3-Adj-Sid), (Recommended Action: Remove the conflicting configuration and reload the router Please collect the console log, show tech-support cef platform. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ACL_GETLIST_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UCP_OLM-7-NO_ACTIVE_IPCC ### Response: (Severity: 7), (Category: ROUTING), (Description: All IPCCs are down or removed for a neighbor.), (Recommended Action: Create a new IPCC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-6-PROTOCOL_STATE_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: The operational status of the E-LMI protocol on the interface has changed. If undesired, the notification of protocol events can be turned off by configuring 'log events disable' on the interface.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_OC48-6-OPTICS_INSERTION ### Response: (Severity: 6), (Category: L2), (Description: Optics module has inserted %d - bay number %d - port number), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-IDBERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Error encountered while attempting to activate an idb. Problem could be corrupt data from IM or IP/ARM or the FRIS.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTF_EA-3-BAD_INTF_EALIB_SERVER_CONTEXT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Interface EA detected a software error where the received library server context does not match the expected value.), (Recommended Action: No action is required as the software has rejected the transaction request.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_CRP-3-GEN_FAILURE ### Response: (Severity: 3), (Category: ROUTING), (Description: General Error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp candidate-rp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp candidate-rp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging process candidate-rp error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging process candidate-rp error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-DEVICE_NOT_REGISTERED ### Response: (Severity: 7), (Category: OS), (Description: Caller's device is not yet registered), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-LTRACE_INIT ### Response: (Severity: 7), (Category: INSTALL), (Description: Failed to register ltrace context structure. Tracing will not be functioning properly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-FGID_ADD_LC_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while creating new node and adding LC to FGID), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REBOOT_LIB-3-SANITY_CHECK ### Response: (Severity: 3), (Category: INFRA), (Description: Error message that reboot history file has invalid reboot data), (Recommended Action: No action is required as the software should be able to recover from this error. Collect reboot history file and show log, then check any previous error while saving reboot cause code.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFEA_IPV6_EA-3-ERROR2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: AFEA IP-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_6_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPP_ASYNC_FIFO_FULL ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPP packet Async FIFO full.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-SEM_POST_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Semaphore Post failed while sending signal to CTRLIO.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists.' 'Contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBAPI-3-BAG ### Response: (Severity: 3), (Category: SNMP), (Description: A problem occurred while encoding or decoding information from a bag.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-2-BOOT_CFG_SYNC_FAILED ### Response: (Severity: 2), (Category: INFRA), (Description: The IOS-XR install infrastructure has failed to distribute its boot configuration to all nodes. In order to bring the node back into sync, the following steps can be taken: - If during an install operation, wait until the install operation is completed - Restart the process instorchagt on the impacted node. This will force a replay of the boot configuration - If restarting the instorchagt process results in the same message being displayed, the relevant node should be reloaded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_CHKPT_DELETE ### Response: (Severity: 7), (Category: FABRIC), (Description: Ingressq encountered an error during Checkpoint delete.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TZ-3-PUF_MAGIC_CHK_ERR ### Response: (Severity: 3), (Category: OS), (Description: This indicate a format error in timezone configuration file.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-WARN_INR_VLAN_SES_THRESHOLD_EXCD ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions for a particular Inner VLAN on the given access interface has exceeded the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-MUTEX_LOCK ### Response: (Severity: 3), (Category: MGBL), (Description: Unable to create exec's event handling thread), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAQFPBridgeCtrl-0-FATAL_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: SPA Bridge ASIC unrecoverable error.), (Recommended Action: Reboot the card. If the problem persists, replace the card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MIRROR-3-ERR_EDM_GENERAL ### Response: (Severity: 3), (Category: MGBL), (Description: 'Encountered an error using a sysdb function. The error is displayed in the error message.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-2-MSG_LOCAL_NODE_NOT_UP ### Response: (Severity: 2), (Category: PLATFORM), (Description: Both the CPUs in DRP needs to be UP for DRP active/standby arbitration. If one of the CPU is UP and the other CPU is not UP, then request shelfmgr to reset this DRP.), (Recommended Action: None; This CPU will reset along with other CPU & SP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCI_HAL_SATORI-3-PDMA_GSP_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: CCI GSP init failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_SYSDB ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA encountered an error using SysDB APIs. The error message describes what operation has failed and why it failed. The most likely reason for this a low memory condition but the error could also be caused by a programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-4-BAG_FAIL ### Response: (Severity: 4), (Category: OS), (Description: An internal bag function failed.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_ETHER-4-INVALID_MAC ### Response: (Severity: 4), (Category: L2), (Description: PLIM driver was unable to get a MAC address for the interface.), (Recommended Action: Check if the process 'shelfmgr' is up and running on the RP. Try to reload the LC to see if that helps. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-4-UNLOCK_FAILED ### Response: (Severity: 4), (Category: OS), (Description: An attempt to lock a mutex failed.), (Recommended Action: Please try restarting the process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-6-GN2412_CHIP_DOWN ### Response: (Severity: 6), (Category: PLATFORM), (Description: GN2412 chip shows the register reading 0xff. Recovery action may take place.), (Recommended Action: 'show controllers epm-switch port-mapping location *') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SYSMGR_REG_LREVT_FAIL ### Response: (Severity: 7), (Category: OS), (Description: Dumper registers with sysmgr for various taks. Sysmgr LR event registration failure. This will lead to unexpected behaviour from dumper.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE0_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE0_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-6-USAGE_STATS ### Response: (Severity: 6), (Category: SYSDB), (Description: Sysdb statistics have been cleared.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_DPM-3-UDLD ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: There has been a mis-wiring or misbehaving satellite connected over the specified interface - the MAC from which the Satellite is reciving SDACP discovery packets is not the MAC address on which this host is sending them.), (Recommended Action: Check and correct the miswiring.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX8508-2-UNCORR_ECC_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: PCIE device uncorrectable ECC error), (Recommended Action: This error is a momentary error and software should be able to correct it. If the issue persists please, contact your technical support representative with the gathered information. No action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-4-ERR_MEM_ALLOC ### Response: (Severity: 4), (Category: L2), (Description: The process failed to allocate memory for the specified resource.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Try to recover from the low memory condition.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHOWCMD-7-SVR_MSG ### Response: (Severity: 7), (Category: SNMP), (Description: 'This is for debug message for show command in snmp to print the buffer '), (Recommended Action: 'This log does not indicate a system impact.' 'all show snmp CLI's for debugging purpose only' 'Recommend customer to re-try the command.' 'If there is no output, reconfigure the snmp settings and re-try') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-4-TEMPLATE_DEAPPLY_ERROR ### Response: (Severity: 4), (Category: MGBL), (Description: The RS232 DLL tried to deapply a template to a TTY but failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-4-CERT_ISNT_TRUSTED_ROOT ### Response: (Severity: 4), (Category: SECURITY), (Description: During IKE phase-I signature verification, the initiator will send a list of its CA certificates. This warning will be printed by the responder if none of the CAs in the list is a trusted root. Note this is not necessarily an error, as there may be multiple cert-req payloads), (Recommended Action: 'Contact remote peer and/or his administrator if session doesn't come up') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAN-3-DRIVER_INIT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is a failure log. The Switch that initializes the Mgmt Port has failed. The process will keep restarting.), (Recommended Action: Collect console log and the following information. - show tech-support mgmt) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_DB_CHKPT_RECOVER ### Response: (Severity: 4), (Category: L2), (Description: When recovering data from checkpoint, an error occurred and the data is lost.), (Recommended Action: Verify that bundle parameters and bundle membership are as expected. Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show interface output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show bundle command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show bundle output, call your Cisco technical support representative and provide the representative with the gathered information. If the data is as expected in the output of both commands then no further action is required, otherwise unconfigure and reconfigure any missing parameters.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-INV_NODEID_EVT_IGNORE ### Response: (Severity: 3), (Category: PLATFORM), (Description: API Call to nodeid_extract_fields() failed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-MY_DOMAIN_CERT_EXPIRED ### Response: (Severity: 6), (Category: SERVICES), (Description: 'The domain certificate of this device ' 'has expired'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the command to display the OSPF routing table in Cisco IOS XR? ### Response: To display the OSPF routing table in Cisco IOS XR, use the command 'show route ospf'. This will display all routes that have been learned via OSPF, including intra-area, inter-area, and external routes. The output will show the destination network, the next-hop, and the outgoing interface for each route. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-EA_ERROR ### Response: (Severity: 3), (Category: L2), (Description: CFM encountered an error while trying to update the hardware packet handling after a configuration update, and retrying the operation has not resolved the problem. This situation could indicate that system resources are low, or a problem with another part of the system. It is possible that CFM will not receive packets that it should be processing, or packet processing may operate more slowly than expected.), (Recommended Action: Restarting cfmd or cfm_ea processes on the affected node may help to update the packet handling correctly. This error may occur as a result of memory exhaustion; attempt to resolve any memory issues before attempting to solve this problem. After system resource issues have been resolved, issue 'process restart cfmd' on the affected node. If that has no effect, issue 'process restart cfm_ea' on the node with the affected interfaces. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-TOP_MEMORY_USERS_INFO ### Response: (Severity: 6), (Category: HA), (Description: This message is emitted when system memory usage crosses a threshold in the direction of increasing memory exhaustion. The top memory users will follow in the next messages. There may be a memory leak or misconfiguration.), (Recommended Action: Collect the data from the following messages and attempt to determine what is driving memory usage. Forward the messages to technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-MMAP_STATS_FAIL ### Response: (Severity: 3), (Category: OS), (Description: mmap of the shared memory required to store shmwin statistic failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture 'show shmwin summary', 'show shmwin trace server', and 'show shmwin trace all'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-ROUTE_RECONCILIATION_IN_PROGRESS ### Response: (Severity: 4), (Category: PLATFORM), (Description: System is booting in warm mode and is resynchronizing routes with the ASIC. Wait for re-conciliation to complete before changing any configuration or performing any impactive operation.), (Recommended Action: No recovery is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_MISSVALUE ### Response: (Severity: 4), (Category: SYSDB), (Description: The command entered requires an item value and one was not supplied.), (Recommended Action: Use the help command to determine the correct usage for this command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-PROC_OPTION_INDEX ### Response: (Severity: 7), (Category: OS), (Description: An inconsistent process core option index value is found for the total size. Shared memory for keeping process core options could be corrupted by someone. Probably software bug, or OS bug.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_LCPM_SHOW-7-USAGE ### Response: (Severity: 7), (Category: PLATFORM), (Description: Startup option supplied to SKP_LCPM_SHOW is not valid.), (Recommended Action: Please re-enter the correct option as described in the usage message 'Usage: skp_lcpm_show [-I ] | [-N ]' the node ID should be used in decimal format. Example: sh controllers pm int Ten0/2/0/0 loc 0/2/cpu0, or run skp_lcpm_show -I TenGigE0_2_0_0 -N 33) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-WARM_RESET_BOOT_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: Card/CCC came up wiht unexpected reset/boot sequence .i.e. in case of warm reset issued card should follow warm reset/boot sequence but instread driver detected PON exectuting/reporting cold boot up.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PFI-3-SET_GLOBALS_MMAP_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Memory map api failure in Platform PFI api. The returned error code should indicate the reason for the failure of the api. This is a transient error in the system likely due to low mem condition etc. The impact to system is minimal except that some global counters are not set. The client calling this api could retry it or handle it accordingly. If the issue is seen persistently, initiate the recommended action.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-7-MGMT_TTY_ATTR_EXTRACT_ERROR ### Response: (Severity: 7), (Category: MGBL), (Description: The show line command was unable to extract attribute for the TTY.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSHD-3-ERR_CREATE_EVENTMGR ### Response: (Severity: 3), (Category: IP), (Description: Attempt to create an event manager fails for some reason), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-6-HBLOSS_COLLECT_COMPLETED ### Response: (Severity: 6), (Category: PLATFORM), (Description: Collection of heatbeat loss log has been completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-4-SR_POLICY_NULL_LABEL_HW_PROFILE_MISMATCH ### Response: (Severity: 4), (Category: FABRIC), (Description: 1. Mismatch found between the current sr policy null label autopush profile and the newly configured sr policy null label autopush profile. Needs attention with LC reload.), (Recommended Action: System LC is inconsistent. Need to reload the LC in order to activate the new sr policy null label autopush profile. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_ERRORS-7-ERR_DMPG_STATE_OVERWRITE ### Response: (Severity: 7), (Category: L2), (Description: ASIC error library encountered a dampening state overwrite condition and failed to get valid memory address.), (Recommended Action: A hardware state recovery action might be needed to restore health of asic. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-MEM_ALLOC ### Response: (Severity: 3), (Category: SNMP), (Description: Due to a low memory condition we not able to process any request or response PDU or we could not allocate memory for context name and not able create view .), (Recommended Action: check the state of process from below CLI's 1)'show snmpd process' 2)'show process block | i snmpd' Please restart snmpd process if still showing the error conatact technical support representative with required info. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-5-CLOCK_INTERFACE_1_OUTPUT_SQUELCHED ### Response: (Severity: 5), (Category: PLATFORM), (Description: When no external clock source is available, this status propagates to BITS output ports in 2MHz and 6.312MHz modes. When an external source is qualified, this alarm will be cleared.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FM-2-FAULT_CRITICAL ### Response: (Severity: 2), (Category: PKT_INFRA), (Description: Critical fault detected. See syslog for fault name, location and fault details.), (Recommended Action: Critical fault. Find the fault name, location and fault details from the syslog. Use the show fm command on that module, use the show alarms command to see if a corresponding alarm is declared on that location. Based on the module and the fault, use the directions/wiki provided by the module owner to decide further action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_EDM-7-BAG_REG_FAILED ### Response: (Severity: 7), (Category: IP), (Description: IPV4 Management Agent encountered failure in registering bag format used to encode information sent via SysDB. It will recover itself by restarting.), (Recommended Action: If the problem persists get the output of show processes, show sysdb trace edm, show sysdb trace clientlib job . If multiple instances of ipv4_ma are seen running or trying to run) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-MD5_TO_STRING ### Response: (Severity: 7), (Category: INSTALL), (Description: Failed to convert package MD5, so processing of the current operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_LMI-3-CODEP_ERROR ### Response: (Severity: 3), (Category: L2), (Description: LMI parameters N392 and N393 are co-dependent - they must obey the rule N392 <= N393. Somehow SysDB is attempting to apply config which conflicts unreconcilably. The parameter being configured is adjusted to be equal to the other.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-TARGET_CFG_COMMIT ### Response: (Severity: 3), (Category: MGBL), (Description: Config process failed to commit target config buffer. Configured items will not be committed in sysdb.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEMLOG-3-SIGERR ### Response: (Severity: 3), (Category: OS), (Description: An unexpected signal value was received.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-TMCAT_DEV_VERSION_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver version is not compatible with the hardware version.), (Recommended Action: Upgrade the Port controller FPGA image using the FPD procedure followed by reloading the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-3-OPERATION_FAIL ### Response: (Severity: 3), (Category: LICENSE), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPA_1P_OC192-7-DEBUG ### Response: (Severity: 7), (Category: L2), (Description: SPA OC192 debug message), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: libpcmcia_linux-7-SLEEPON_LOCK_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: deadlock error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAA-6-CLOSE ### Response: (Severity: 6), (Category: SECURITY), (Description: This is an info message from debug module of aaa component. This indicates that user has succesfully logged out.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_400G_POD-3-RX_CH_HI_PWR ### Response: (Severity: 3), (Category: FABRIC), (Description: The POD detects a high power on a channel. The channel might not be functioning properly, and can cause cell drops, or corruption from received cells.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_EA-6-PRINT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: PLATFORM FIB EA, Information), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGMP_MTRACE-3-INIT_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: Initialization error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information as given in the required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-6-SESSION_INHERIT_ON ### Response: (Severity: 6), (Category: L2), (Description: The specified BFD session is now inheriting BFD state from another BFD session.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-3-WC_LICENSE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Unable to get license status from license manager due to an internal license software error. The error message describes the error.), (Recommended Action: Please try to recover by reloading the line card which generated the error. If it doesn't resolve the issue, please try to gather the output of the CLI before reloading the LC. 'show tech-support ethernet interfaces', 'admin show license tech-support', 'admin show tech smartlic' 'admin show license trace platform' And if the issue persists, contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-6-CBC_REFRESH_PWR_SEQ ### Response: (Severity: 6), (Category: PLATFORM), (Description: CBC has detected there there is a CRC check failure in the power sequencers on this card and attempting to reprogram the sequencers in error.), (Recommended Action: Verify the status of the power sequencer programming using: Copy the error message exactly as it appears on the console or in the system log. Issue the (admin)# show env trace pwrseq command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin)# show env trace pwrseq output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-6-REPLACE_UNSUPPORTED ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Satellites using an older software version cannot perform replace operations initiated by this host software version. The satellite should be upgradeD to use the same software version as the host. If this is not possible then the transfer / activate / update / deactivate / remove operations may be used to provide the same functionality.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-SRGB_FREE_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured while attempting to free the segment-routing global block (SRGB) If this error occurs because of configuring or deconfiguring the global block, then segment-routing will not functional at all. As a result, likely cause of this problem is that some other application (e.g. LDP, BGP) are using labels within the global block), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FMGR-3-MATCH_TYPE_IN_ACL_NOT_SUPP_AFMON ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Only the following match types specified in an ACL are supported as part of an AFmon policy: Source/ Destination IP address, Source/ Destination Port values. An ACE containing any other match types will be ignored i.e. it will not be programmed in hardware.), (Recommended Action: No further action is required if the policy programming behavior, which is explained here, is acceptable. Otherwise the policy can be removed and an acceptable one re-applied. 'no service-policy input|output') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_AIB ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error communicating with the AIB server. The error message describes what operation has failed and why it failed. The most likely reason for this is a temporary connection problem with the AIB server, but the error could also be caused by low memory resource or programming error.), (Recommended Action: In many cases, PPP MA will recover by itself. If it does not then restarting the process may help. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY_CONNECT-3-MEMORY ### Response: (Severity: 3), (Category: MGBL), (Description: The TTY Connection library has failed to acquire the required amount of memory), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: FABRIC), (Description: Ingressq encountered a fatal memory allocation error. If a new configuration being applied, the configuration will be rejected. The user may reapply the configuration. If the error happens normal operation, the process will restart to recover from this error.), (Recommended Action: The driver/client processes try to recover from this error. If any discrepancies are found in the device functionality, contact TAC Support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP best path selection process? ### Response: The BGP best path selection process is used to determine the best path to a destination when multiple paths exist. The process evaluates paths based on attributes like weight, local preference, AS path length, origin, MED, etc. in a defined order until a single best path is chosen. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-3-IM_RATE_UPD_FAIL ### Response: (Severity: 3), (Category: IP), (Description: A software error occurred when the ANCP process tried to publish rate updates through the interface manager. One of the most probable reason for the error is that Interface Manager process is not available or is restarting at the time of the operation. ANCP will attempt to recover by retrying the update in question.), (Recommended Action: The process will attempt to recover from this situation by retrying. If this message is not seen again and if rate is getting updated after sometime (few tens of seconds), then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-6-DISCOVERY_FAILED ### Response: (Severity: 6), (Category: INFRA), (Description: Failed to get config file location from the DHCP server. Will retry with different fetcher.), (Recommended Action: Verify DHCP server connectivity and configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CVAC-4-CONFIG_START ### Response: (Severity: 4), (Category: MGBL), (Description: The CVAC (Cisco Virtual Appliance Configuration) subsystem is proceeding to read and apply router configuration from the specified file. More information can be found in the provided file or CLI command.), (Recommended Action: Informational message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_MRT-7-DEBUG_INIT_EVENT ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDBUTILS-6-FILEOPEN_FAIL ### Response: (Severity: 6), (Category: SYSDB), (Description: Operation to open the SysDB log file has failed.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-3-INIT_NON_FATAL ### Response: (Severity: 3), (Category: SERVICES), (Description: A non-fatal failure occurred during the initialization of the specified module of RSPP MA, the process responsible for managing the diversion of packets to services such as firewalls. This will typically mean that some level of debugging support will not be provided for the process (e.g. error codes will not be decoded), but the functioning of the process is not otherwise affected. Restarting the process should restore full debugging support.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-INVALID_PLIM_PORT ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: EINT was supplied with a plim port that exceeds the limit of num ports.), (Recommended Action: Collect console log and the following information and contact TAC support with this info Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. -debug netio drivers location -show netio trace all location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option loose feature? ### Response: The MPLS TE path-option loose feature allows an explicit path to be specified using a combination of strict and loose hops. Strict hops must be directly connected to the previous hop, while loose hops are not required to be directly connected. Loose hops provide more flexibility in the path calculation. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-FC_IN_RESET_STATE ### Response: (Severity: 4), (Category: PLATFORM), (Description: One Fan controller is put in IN-RESET. System is running simplex with single FC. If other FC also goes down, then the chassis will be shut.), (Recommended Action: Replace the FC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-DB_DELETE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: A user requested that an object be removed from a database in which it was not present. The process should recover from this event, but it may indicate an internal inconsistency which could cause other problems.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-SWITCH_DMA_MEM_ALLOC_MISMATCH ### Response: (Severity: 3), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process detected mismatch in DMA allocation address of the switch. When this occur switch won't be initialized properly. In order to recover, the ESD process resets the switch, then exits so that it is restarted by the process manager.), (Recommended Action: If this problem does not recur, no intervention is required to recover. To determine why this problem occurred, or if the problem occurs multiple times, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet' and 'show tech-support ctrace' commands. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure OSPF on Cisco IOS XR? ### Response: To configure OSPF, use the 'router ospf' command in global configuration mode. RP/0/RSP0/CPU0:router#config RP/0/RSP0/CPU0:router(config)#router ospf 100 RP/0/RSP0/CPU0:router(config-ospf)#area 0 RP/0/RSP0/CPU0:router(config-ospf-ar)#interface GigabitEthernet0/0/0/0 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_5_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMDR-5-CLIENT_INIT_LTRACE_FAILED ### Response: (Severity: 5), (Category: OS), (Description: 'Ltrace utility registration failed.' 'Ltrace functionality may not work properly.' 'IMDR will proceed without fail.'), (Recommended Action: 'Restarting the process may resolve the issue.' 'If the problem persists after some tries, contact tac.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET_LOOPBACK-3-IM_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize IM connection in the platform Ethernet loopback component), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-OUT_OF_EVENT_LOOP ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'While waiting for events from AIB. Reached Out of event loop .' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists.' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_THOR_L2FIB-3-DEBUG_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-SYMBOL_NOT_FOUND ### Response: (Severity: 3), (Category: OS), (Description: A dll notified from a client is not found This leads to failure in coalesce functionality of OBFL.), (Recommended Action: Please restart the obflmgr process. If the issue is seen even after restart then please collect the following data and contact support. collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-OPTICS_EDC_SERDES_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Serdes signal fault detected/cleared between optics and EDC.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-4-LOG_MTU ### Response: (Severity: 4), (Category: IP), (Description: The link MTU is lesser than the IPv6 link MTU. Hence the operational MTU is set to the link MTU and not the configures MTU value), (Recommended Action: Choose IPv6 MTU value lesser than the LINK MTU value) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-SHUTDOWN ### Response: (Severity: 3), (Category: OS), (Description: An NRS Server hit an error from which it could not recover and is restarting to continue normal operation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-NODE_KERNEL_DUMP_EVENT ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that the specified node is doing a kernel dump. This can happen in case of a failure that leads to the node software deciding to do a kernel core dump and then reset the node.), (Recommended Action: Please collect the following information and then contact your Cisco technical support team. - the kernel core files from the RSP harddisk) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TORNADO_ARBITER-3-FABRIC_ARB_TRANSIENT_LINK_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates an error condition where the arbiter driver encountered transient fabric link fault and attempted to bring the link up.), (Recommended Action: This message may indicate a condition where the arbiter driver encountered transient fabric link fault and attempted to bring the link up by toggling the serdes and MAC level RX. If the message is seen continuously when the card is in IOS XR RUN state then please contact tech-support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-SHIP_REG_FAIL ### Response: (Severity: 7), (Category: SYSDB), (Description: Registering with stats infra failed.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-2-LC_EOBC_FAILED_RSP0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: This line card has lost EOBC heartbeat to RSP0.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CRYPTOMAP-3-DBG_ERROR ### Response: (Severity: 3), (Category: OS), (Description: An debug init/fractL call failed and error is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_UTIL-7-WARNING ### Response: (Severity: 7), (Category: HA), (Description: This provides information about non-error conditions which may even be expected under certain circumstances. Nevertheless, these are not considered 'desirable' conditions.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-6-SYSDB_BLOCK_RECOVER ### Response: (Severity: 6), (Category: OS), (Description: SSM process detects sysdb becomes available. It will register with sysdb to read new configurations.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-INVALID_BOARD_CLASS ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC driver cannot handle the detected CCC board classification.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-GET ### Response: (Severity: 4), (Category: MGBL), (Description: An error occurred invoking an MDA function. This could be because the object to fetch does not exist. The details are in the error string.), (Recommended Action: Check that the requested object exists. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-5-SESSION_CLEAR ### Response: (Severity: 5), (Category: MGBL), (Description: This message indicates that the session specified in the message had been cleared via CLI 'clear configuration session '.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-INVALID_OBJECT_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code. Here is a list of possible reasons for this message (not all-inclusive). - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef trace location <> show cef platform trace all location <> show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: ROUTING), (Description: Failed to allocate memory for RIB operations probably out of memory because of huge configuration or a memory leak.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_0_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCASTSN-5-THRESHOLD_REACHED ### Response: (Severity: 5), (Category: L2), (Description: The threshold value set has been reached. Max number of allowed groups will soon be reached. considering reconfiguring max group limit or loose some states.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTQ2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ_MGR-3-ERR_FBP_CFG ### Response: (Severity: 3), (Category: FABRIC), (Description: The Fabricq received an invalid Fabric Back Pressure configuration from fsdb.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-FGID_ISSU_UNREG_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while trying to un_register for ISSU notifications.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option dynamic attributes feature? ### Response: The MPLS TE path-option dynamic attributes feature allows certain LSP attributes to be specified for a path-option without configuring an explicit path. LSP attributes that can be specified include bandwidth, priority, affinity, and setup and hold priorities. This provides a way to influence the dynamic path calculation with additional constraints. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-ERR_PLIM_SERVICES_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in initialization of PLIM Services driver. If this occurred during process startup or RP Switchover, then the process may be restarted.), (Recommended Action: Restart the plim_services process (process restart plim_services location <>) If the issue persists, do a cold reboot Services PLIM MSC.If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-BADHRCHY ### Response: (Severity: 7), (Category: MGBL), (Description: An invalid hierarchy was entered by the user.), (Recommended Action: Use the 'children' command to progressively find out the correct hierarchy string. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAW_LIB-3-SEEK_TLV_OFF_FAILED ### Response: (Severity: 3), (Category: MEDIA), (Description: Function write_tlv_in_offset write the TLV data which is being pointed by region offset. This function used to for writing NVRAM TLV from XR. Set the offset position in the nvram file and write the reboot history record. Fseek failed for the provided offset for that nvram bin file. Refer the reason why it is failed.), (Recommended Action: Based on the failed reason, please take steps. Listing few actions, erase nvram-raw: loc may solve the issue. If erase doesn't help, please contact the TAC team for further help.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-SIA_EVAL_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: Your evaluation period has expired. Register the device with Cisco. Software upgrades will be blocked once the SIA grace period of 90 days expires. Please check show license platform summary/detail for more information.), (Recommended Action: Customer should register the device to Cisco.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RUNA-2-ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Error in RUNA operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-ISSU_ON_ABORT_NO_RELOAD_ISM ### Response: (Severity: 6), (Category: INSTALL), (Description: When initiating the ISSU operation, the user specified the on-abort no-reload option. This message indicates that on abort, no recovery will be done by ISSUMgr. The user has indicated 'on-abort no-reload' hence, no abort actions will be performed as part of abort. This is a non-error condition.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-ERR_THREAD_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA driver failed to create the identified thread during driver initialization.), (Recommended Action: The driver will escalate the error to the Fault Management (FM) entity for further action. Verify that the driver will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_HFR_LIB-3-LTRACE_NODE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to open the directory path for ltrace. %s-Directory Path. %s-Error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-DB_CLEAR_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: Error encountered when attempting to clear the DB. DB might be in any state now & so usage of hat DB might fail with unexpected results.), (Recommended Action: Collect the output of show logging and inform Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Also, restarting the acctd DB process might help recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABMGR-3-MIXED_MODE_FC ### Response: (Severity: 3), (Category: PLATFORM), (Description: Fabric running in mixed-mode. Please upgrade/downgrade all FCs to same type of Fabric Card.), (Recommended Action: Fabric running in mixed-mode. Please upgrade/downgrade all FCs to same type of Fabric Card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-SHUTDOWN_STANDBY_RP ### Response: (Severity: 4), (Category: PLATFORM), (Description: This msg means that shelfmgr is shutting down RP/SC as its a user initiated shutdown.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure BGP route reflector clusters in IOS XR? ### Response: BGP route reflector clusters in IOS XR are configured to allow a set of route reflectors to act as a single entity. router bgp 65000 neighbor 192.0.2.3 route-reflector-client cluster-id 1 commit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-6-CONNECTION_DENY_ACL_ERROR ### Response: (Severity: 6), (Category: MGBL), (Description: TTY management denied the requested connection due to ACL mismatch. Please check the configuration for applied ACL.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-6-TRIGGER_SO ### Response: (Severity: 6), (Category: ROUTING), (Description: If NSR switch-over is configured, active ldp will trigger the switch over in case of TCP failure or LDP failure, if NSR is ready and an install operation is not in progress.), (Recommended Action: This message is for information purpose only. Analysis should be done if switch-over is not expected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP_NSR-3-FO_NOT_INITIATED ### Response: (Severity: 3), (Category: IP), (Description: TCP's NSR module is trying to initiate a fail-over to maintain NSR, but either all NSR clients are not yet ready or NSR clients with the highest weight are not yet ready. So, a failover will not be attempted.), (Recommended Action: Check which NSR client was not ready and if required collect relevant logs for that process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-2-REBOOT ### Response: (Severity: 2), (Category: OS), (Description: A critical process ran into trouble.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C_SERVER-3-GN2412_CHIP_RECOVERY_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to recover the chip. Card will be reloaded.), (Recommended Action: The RP on which the fault has occurred will reload automatically to attempt recovery.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO_COMMON-3-HA_PMW_CONN_REG_RETRIES ### Response: (Severity: 3), (Category: L2), (Description: ELO has failed to connect and register with the Process Manager Infrastructure after multiple retries. Reconnection and registration will continue to be retried at a slow rate. If ELO fails to connect with Process Manager, it will not be notified of the ISSU switchover, and may result in unexpected behaviour.), (Recommended Action: Check the status of the Process Manager process for any obvious errors. Unless ELO can reconnect to Process Manager, it will not be notified of the ISSU switchover, and so the ISSU operation will likely need to be aborted and retried. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-6-ERR_IFH ### Response: (Severity: 6), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: B_SHIM_PARTNER-3-SET_CALLBACK_ERR ### Response: (Severity: 3), (Category: L2), (Description: 'There is a software error when trying to set call-back to IM.'), (Recommended Action: Check if IM is working fine or not by executing CLI 'sh process ifmgr location <>'. Try performing IM process restart by executing CLI 'process restart ifmgr location <>'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-6-BACKUP_DSC_NOTIFICATION ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates DSC sending backup notification.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the planes into which the IOS XR architecture is logically divided? ### Response: The IOS XR architecture is logically divided into a management plane, control plane, and data plane. The management plane provides CLI, XML, and SNMP based configuration and monitoring. The control plane runs routing protocols, signaling protocols, and other control functions. The data plane performs packet forwarding in hardware. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-6-AAA_LOCK ### Response: (Severity: 6), (Category: MGMT), (Description: This is expected when aaa database is locked by some other program, retrying to configure to user would not give this message), (Recommended Action: Retrying to configure to user would not give this message and allow user to configure first user, if issue persists then collect show aaa trace login location /show aaa trace sync location , the work-around would restart configuration database) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-1-ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: The PCIe server has detected an error condition. The message has the error information.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA_MGR-5-OIR_INSERTED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-LPTS_POLICY_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Some socket/lpts error occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: T1E1-3-ERROR ### Response: (Severity: 3), (Category: L2), (Description: A general failure occured while executing the function in question. The message contains info about the location and cause of the failure and possibly anticipated actions/effects.), (Recommended Action: Verify continued correct operation of T1E1.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-LRD_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-3-ADJ_ERROR ### Response: (Severity: 3), (Category: L2), (Description: A runtime error occurred in ASR9K adjiacency module. The reason for the failure is also displayed. Please call Cisco Support with the error information.), (Recommended Action: Please collect the console log and following traces: show cef trace loc show cef platform trace [common|ipv4] all loc show adjacency hardware trace loc show bundle trace all loc show im trace loc Most of the time, these are harmless transient messages, caused by the delay in FIB and AIB processes learning about new interface. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-4-BDL_LB_INIT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: An error was encountered while the specified library was initializing.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-CARD_UNPOWERED ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates that requested node cannot be powered up because its in admin-config power-disabled state.), (Recommended Action: Remove node's power-disable config via CLI and then try again: (admin-config)#no hw-module power disable loc <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DAPS-6-POOL_BLK_DONE ### Response: (Severity: 6), (Category: IP), (Description: All Ip addresses belongs to the blocked pool is now release. This range in now available to be asinged to a new pool.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-0-SOFT_ERROR_RELOAD_RECOVERY ### Response: (Severity: 0), (Category: FABRIC), (Description: Soft error detected on FIA instance. Card will be reloaded to cover from this error.), (Recommended Action: Soft error are very rare due to Cosmic and other environmental factors. The probability of soft error on same device again is extremely low. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_DEBUG ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the debug service. The error message describes what operation has failed and why it failed. The error could be caused by low memory resource or programming error.), (Recommended Action: In many cases, PPP MA will recover by itself. If it does not then restarting the process may help. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_SERVICE_EA-3-ERR_UIDB_INIT ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to set up connection with UIDB server process.), (Recommended Action: When this issue happens, it will trigger an automatic restart. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-1-BOARD_FPGA_NOT_ACCESSIBLE ### Response: (Severity: 1), (Category: PLATFORM), (Description: Detected Sarva FPGA is not accessible while polling the prsent bit.), (Recommended Action: power-on reload SC-GE-22-B card. consider RMA SC-GE-22-B card if issue persists.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_QFPCPUCTRL-1-ERP_PAR_ERROR_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: CPU controller FPGA detected a parity error on the SPAQFPBridgeCtrl0 ERP bus during data reception from SPAQFPBridgeCtrl0.), (Recommended Action: Reboot the board. If the problem persists, replace the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-3-ETHSERVER_WRITE ### Response: (Severity: 3), (Category: PLATFORM), (Description: A communication problem occurred between the MBI client and Ethernet server. The MBI operation in progress will not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS traffic engineering auto-tunnel backup feature? ### Response: The MPLS traffic engineering auto-tunnel backup feature allows point-to-point backup tunnels to be created dynamically to protect MPLS TE tunnels and the IGP against link and node failures. Backup tunnels are created for neighboring routers and provide fast reroute protection. It is enabled with the mpls traffic-eng auto-tunnel backup command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_DUPLIATE_INSTANCE_ID_ON_INTERFACE ### Response: (Severity: 3), (Category: ROUTING), (Description: Multiple isis instances with same instance-id enabled on an interface.), (Recommended Action: Make sure no two isis instances with same instance id can be configured on an interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-3-SYSMGR_RESPAWN_COUNT ### Response: (Severity: 3), (Category: TOPOLOGY), (Description: System Admin Manager failed to get respawn count from sysmgr.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-3-NBR_DOMAIN_CERT_REVOKED ### Response: (Severity: 3), (Category: SERVICES), (Description: 'The domain certificate of the neighbor device ' 'has been revoked'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCT_EA-3-INIT ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: Initialization process such as getting an evm failed. The acct_ea process cannot proceed without this module initialization, and will exit.), (Recommended Action: sysmgr will retry to start the acct_ea process. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-5-ROUTE_TRUNCATE ### Response: (Severity: 5), (Category: ROUTING), (Description: A FIB prefix links to a load-balance that has been truncated. This means that paths that the control plane has identified as equal-cost, are not being used for forwarding. This occurs when the linecard that has emitted this error does not have the capabilities to support this many ECMP paths. This is indicative of one of two conditions: 1 - the route producer (i.e. OSPF, BGP, etc) has been configured to provide more equal-cost paths than all linecards in the system can support. In this case all line cards will be emitting this error. This will not result in traffic loss as all linecards will truncate the load-balance in the same way, and will thus all have identical forwarding programmed. This will NOT result in any traffic loss. 2 - Only this linecard has insufficent capabilities to support a load-balance of this number of paths. In this case all traffic to this prefix through this linecard (ingress or egress) will blackhole), (Recommended Action: reduce the maximum number of equal-cost paths generated by the route producer to a value that all cards in the system support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-6-LOAD_LICENSE_FILE_OK ### Response: (Severity: 6), (Category: LICENSE), (Description: The license manager has installed all the licenses in the named license file to the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TIMER-3-TWTIMERERROR ### Response: (Severity: 3), (Category: OS), (Description: Couldn't manipulate OS timer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PDMA_SPP-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: PLATFORM), (Description: PDMA SPP dll Memory Allocation Error message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn spp process, up to a fixed number of times the error is encountered, to recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_BMADJ-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM BMADJ, error information), (Recommended Action: Please collect the console log, bundle traces (show bundle trace loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-3-INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB server failed initialization with above reson.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_LIB-7-SYSMGR ### Response: (Severity: 7), (Category: INSTALL), (Description: An error occurred while the Install infrastructure was interacting with System Manager, and so the requested operation may not be completed.), (Recommended Action: Some processes did not complete the software change in time. Please retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-FAULT_SIMULATION_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: Simulation of fault condition requested was not perfomed due to failure.), (Recommended Action: No all fault simulation are supported on all the card types. Please select the right fault simulation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLCTRLR-4-UPDOWN ### Response: (Severity: 4), (Category: L2), (Description: The specified MLCTRLR is operationally down due to alarm. Check alarm status using show controller Mlt command on the cli.), (Recommended Action: Recommended action is to repair the source of the alarm.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_SHOW_PROCESS-7-LTRACE ### Response: (Severity: 7), (Category: HA), (Description: ltrace_init failed), (Recommended Action: Collect system log information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ETHER-2-XGXS_DTE_SYNC_ERROR_RECOVERED ### Response: (Severity: 2), (Category: L2), (Description: The PLA MAC xgxs DTE layer went down due to loss of sync or lane alignment. The traffic may start getting dropped after this error message.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SESVI_EA-3-SSC_SEND ### Response: (Severity: 3), (Category: SERVICES), (Description: A problem was encountered while trying to send a batch of messages to the Service Director. The Service Director may not be up to date with the state of services on this node, so SESVI interfaces located on this node may fail to forward packets.), (Recommended Action: It may help to restart the SESVI EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_LOS_PORTT ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG_PLAT-3-ISM_COULDNOT_REGISTER_NOTIFY_SHELFMGR ### Response: (Severity: 3), (Category: INSTALL), (Description: Retry registration fixed number of times. ISM could not register for node state notify with shelfmgr.), (Recommended Action: Please contact TAC after trying maximum retries.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-4-DLL_MANAGER_SETUP_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: The attempt to setup the rpl remote dll coordinator failed. This will prevent the rpl coordinator from running and may prevent route policy from executing.), (Recommended Action: Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICCP-5-NEIGHBOR_STATE ### Response: (Severity: 5), (Category: INFRA), (Description: An ICCP neighbor has changed state (up/down).), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_1_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLUTLU-3-MIPC_UNCORR_ERR_NOTIF ### Response: (Severity: 3), (Category: PLATFORM), (Description: TLU received notification from MIPC due to unrecoverable error or invalid address. client downloads the entire table to hardware as a recovery mechanism. This is an informational message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTAGENT-3-MISC_DISK1_NOT_FOUND ### Response: (Severity: 3), (Category: INFRA), (Description: Install agent process is spawned but /misc/disk1 directory do not exists on this node. /misc/disk1 is mandatory to execute this process.), (Recommended Action: The reason for this failure has to be analyzed. Collect the show tech logs by running 'show tech-support install', 'show tech-support os' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMONMIB-3-ERR_MUTEX ### Response: (Severity: 3), (Category: SNMP), (Description: The MIB had trouble locking/unlocking mutex.), (Recommended Action: Please collect 'show tech-support performance-traffic' and contact Cisco technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: tunnel_ea-3-EVENT_BLOCK_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This is typically an internal error in the software. The software failed to initialize the code that handles/processes events related to tunnel_ea.), (Recommended Action: If there is a problem, it might be cleared by restarting tunnel_ea. If the problem persists, copy the error message as it appears on the console and any noticeable side effects. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIER-2-PCIE_2_ROOT_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PCIE error detected in Root Complex 2), (Recommended Action: Please correct the problem by reloading the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-4-_OOR_YELLOW ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is a severe error message in the OFA module to indicate high usage of OFA resources.), (Recommended Action: Please collect the OFA resource information (show controller npu resources all location all). Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBQSMGR-3-SEND_ABORT_FAILED ### Response: (Severity: 3), (Category: INSTALL), (Description: The communications channel to QSU Manager is unavailable.), (Recommended Action: The process is automatically restarted, which should trigger a QSU abort - the QSU may be attempted again at this point. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the log-adjacency-changes command in IS-IS? ### Response: The log-adjacency-changes command is used to enable logging of IS-IS adjacency state changes. When enabled, the router logs messages when an adjacency comes up or goes down. This is useful for monitoring the stability of IS-IS adjacencies and for troubleshooting adjacency problems. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-7-BIND_MTD_SOCKET_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Bind mtd to socket failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check the card is a Cisco approved device if it is externally accessible. Capture 'show filesystem ' together with console log.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAIPC_NETIO-7-BASE_CONTROL_FUNC_ERR ### Response: (Severity: 7), (Category: OS), (Description: qnetbase_control_func() wrongly called.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_THREAD_DESTROY ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to destroy a thread. This is an internal error. If the error occurred whilst unconfiguring IS-IS then it may be necessary to forcefully terminate the IS-IS process. If the error occurred during normal operation then it may be necessary to restart the IS-IS process to recover.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSV_APP-3-BIND_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failed to bind, this may be program level issue), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure a user with privilege level? ### Response: To configure a user with a specific privilege level, use the 'username' command in global configuration mode. RP/0/RP0/CPU0:router(config)#username admin privilege 15 secret 0 admin1234 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-3-INIT_ERROR_INSUFFICIENT_DISKSPACE ### Response: (Severity: 3), (Category: INSTALL), (Description: Disk does not have sufficient space for insthelper to continue on. The difference from 'INSUFFICIENT_DISKSPACE' is node is not being held in MBI.), (Recommended Action: Please remove unwanted files/directories and retry the operation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-6-FW_MGR_OPERATION_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: These messages indicate some kind of info related to the auto FPD upgrade process when it runs in the context of the install upgrade.), (Recommended Action: No action is needed from the user. This is to inform the user about certain details on the FPD process. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-4-ERR_MGD_TIMER ### Response: (Severity: 4), (Category: L2), (Description: MFR MA encountered an unexpected error using the Managed Timer library. This is most likely due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the MFR MA process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of BGP route dampening? ### Response: Route dampening minimizes the propagation of flapping routes across an internetwork. Criteria can be defined to identify poorly behaved routes which are suppressed. Dampening parameters include a penalty value, a suppression limit, a reuse limit, and a maximum suppress time. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR-3-PM_REPORT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error in raising alarm to Fault Manager. This may be a program level error. The failure will cause the Procmgr process to restart.), (Recommended Action: The Procmgr process will automatically respawn up to a fixed number of times. Verify the process is running: 'show process procmgr location <>' If it is still not spawned contact support with the required info. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBSOC-6-SHOW_CONFIG ### Response: (Severity: 6), (Category: OS), (Description: Print socket configuration.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_EDM-3-PROTO_REG_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: OSPFv3 was unable to register for support of the show protocol command.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-6-ROOT_DEVICE_BUS_INFO_THRESHOLD_EXCEEDED ### Response: (Severity: 6), (Category: PLATFORM), (Description: A root device has been detecting a PCIe bus error and it is exceeding threshold. The message has the device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LSPV-4-show_timeout ### Response: (Severity: 4), (Category: ROUTING), (Description: It was not possible to obtain the lock required to access the databases. This may be due to the main thread being very busy processing events.), (Recommended Action: Wait a few minutes, and re-attempt to issue the show command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-NPU_0_TS_UPDATE_ERR_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Timestamp update error on NPU-0 interface on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ temperature greater than or equal to the high temperature alarm threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_LA_QOS-2-MIN_VOQ_VSC_VALUE_NEEDS_UPDATE ### Response: (Severity: 2), (Category: QOS), (Description: SDK suggested minimum allocatable VOQ/VSC is different than being used in XR), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-BRM_ERR_RESET ### Response: (Severity: 3), (Category: FABRIC), (Description: Error detected in Input barrier from FQM), (Recommended Action: If the error persists, please contact TAC suppport.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_PLIM_SB-3-MSG_REPLY_FAIL ### Response: (Severity: 3), (Category: L2), (Description: A message to the specified SPA did not receive a reply. The reason for the failure is specified in the message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-4-ASSERT ### Response: (Severity: 4), (Category: IP), (Description: 'LISP control plane code execution encountered an unexpected condition.'), (Recommended Action: 'If LISP process dies, it will attempt to recover from this situation by ' 'restarting.' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ct_agent-3-ERR_SYSDB_UNPACK ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EES-4-ENOSPACE ### Response: (Severity: 4), (Category: PLATFORM), (Description: EES warning message.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the max-link-metric command in IS-IS? ### Response: The max-link-metric command is used to configure the maximum link metric that IS-IS will advertise. By default, IS-IS advertises the actual link cost. However, in some scenarios, you may want to advertise a link as unreachable without actually shutting down the link. Setting the max-link-metric to a high value (up to 16777214 for wide metrics) effectively makes the link appear unreachable to other routers. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ET0_INTR_SOP_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ET0_INTR_SOP_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-7-INCORRECT_CBP_ACCESS_COUNT ### Response: (Severity: 7), (Category: OS), (Description: CBP access count records the number of threads accessing the CBP. Access count shall be greater than 0 when it is to be descreased), (Recommended Action: Collect show tech-support gsp and process restart client if client has any group communication issue) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAL_IPHC-3-EA_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: IPHC pal ea error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE6_LANE_CRC_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE6_LANE_CRC_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-CARD_VOLTAGE_ALARM ### Response: (Severity: 4), (Category: PLATFORM), (Description: The card voltage sensor has been monitored below or above it's operational range. If the voltage continues to fall or rise, the HW power sequencer may reset the board.), (Recommended Action: Verify the failure, give CLI: (admin)# show env table --> voltage sensor threshold ranges (admin)# show env --> all sensor output (exec)# show env led details Specifically look at voltage sensor values, can refine the output by giving show env volt) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_DIAG-3-FILESYS_BASIC_FAILURE ### Response: (Severity: 3), (Category: DIAG), (Description: The diagnostic test for basic file system devices such as disk0, disk1, harddisk respectively has detected an error condition, if the devices are not present or having some access issues.), (Recommended Action: Collect the console error messages exactly as it appears on the console and call cisco support engineers with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VCDMA-3-ERR_DLL_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cpuctrl driver tried to register for a dll but it encountered an error. The driver might lose some of its functionality.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FLOWTRAP-4-BAD_ACTOR_INTF_DELETED ### Response: (Severity: 4), (Category: OS), (Description: An interface that was previously flagged by the punt flow trap has been deleted, and so the 'penalty box' for it has been cleared.), (Recommended Action: No action necessary. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_LMI-3-IDB_SEARCH ### Response: (Severity: 3), (Category: L2), (Description: The message indicates that an exact match on the interface handle was not found.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-HA_PP_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: HA Punt path test failed, reloading ISM.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COMMS-4-DUPLICATE_ENTRY ### Response: (Severity: 4), (Category: L2), (Description: When reloading the list of known nodes from checkpoint, a duplicate entry was encountered. This is unexpected, and likely indicates a software fault, but is otherwise harmless. The duplicate entry has been removed and the process should continue to operate as expected.), (Recommended Action: This message is usually harmless and the system will recover. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-4-PARSER_DLL ### Response: (Severity: 4), (Category: ROUTING), (Description: A system call failed inside the routing policy parser DLL.), (Recommended Action: Try again: the failure might have been due to resource issues. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRP_UPGRADE-6-COMPLETE_SYNC ### Response: (Severity: 6), (Category: MGBL), (Description: Sync successfully completed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_EVM_ASYNC_ATTACH ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP-4-WARN_CONN ### Response: (Severity: 4), (Category: IP), (Description: The connection from ARP to the specified service has failed and cannot be recovered. In this situation ARP restarts and this should resolve the problem.), (Recommended Action: Please collect the output of show tech-support arp. If the issue is seen repeatedly Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCTL-3-gsp_msg_failed ### Response: (Severity: 3), (Category: PLATFORM), (Description: The internal communication channel among pctl threads is broken.), (Recommended Action: If issue still persists, collect 'show tech-support gsp'. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-4-CONFIG_NEXTHOP_ETHER_INTERFACE ### Response: (Severity: 4), (Category: ROUTING), (Description: The static route via ethernet interface without nexthop is configured. This may cause come inconsistancy.), (Recommended Action: Refer to the configuration guidelines for static route nexthop interface) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JBI-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message from the altera JTAG player), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_PERSIST_PON_RESET ### Response: (Severity: 1), (Category: PLATFORM), (Description: An ASIC error has occured and need a power on reset.), (Recommended Action: An error has happen and PON reset has been performed to recover. Collect required information and contact TAC *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LINEPROTO-5-DAMPENING ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: The interface line protocol dampening state changed. When the state is 'suppressed' the interface will be held down. In 'unsuppressed' state, link state changes are allowed to occur as normal.), (Recommended Action: If the dampening state change was unexpected, confirm the configuration settings for the interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-3-ERR_RX_FBP ### Response: (Severity: 3), (Category: FABRIC), (Description: The Fabricq ASIC is configured to expect fabric backpressure informtion for a particular set of groups on a small set of links. This error indicates that incoming backpressure information doesn't match the expected config.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-EVENTBLOCK ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred while a thread was blocked waiting for an event. *RECUR*), (Recommended Action: Please provide output from the following commands: - show tech-support routing ospfv3 detail - show configuration failed - show configuration history 5 - show commit changes ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ACL-4-IPACCESSRLIMIT ### Response: (Severity: 4), (Category: ACL), (Description: The ACL library has requested the operating system to grant additional heap memory. The request has failed and the error indicating the reason has been given), (Recommended Action: Collect the requested show tech-support info and forward it to development engineering team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: C_SHIM_PARTNER-7-IM_CALLBACK_ERR ### Response: (Severity: 7), (Category: L2), (Description: 'There is a software error when handling messages from IM.'), (Recommended Action: Ignore) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-4-RX_LOS ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message provides information about the fault occurred on the interface.), (Recommended Action: The message is just for information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-6-CLIENT_ID_WARNING ### Response: (Severity: 6), (Category: INFRA), (Description: Use of exr-config for Client ID and user-class of DHCP options is deprecated. They will be completely removed in a future release.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_LIB_ACCESS-3-MSG_SEND_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: A communication problem occurred between the MBI client and server. The MBI operation in progress will not be carried out. However, the MBI client will continue trying to send the message to the server. In the event that the operation continues failing, then the card could be rebooted by the RSP.), (Recommended Action: No action is needed if the card boots up and reaches IOS XR RUN state. If the card can not reach IOS XR RUN state despite getting rebooted and the errors persist please collect the following information and contact your Cisco technical support representative: 1. The console output of the active RSP from user login till the end. Please make sure the above error message(s) are included. 2. (admin)#show install trace mbi-hello location 3. The output of the following CLI commands:) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-TX_ALARM_SC ### Response: (Severity: 3), (Category: PLATFORM), (Description: Condition raised by BITS transmitter when internal short-circuit resistance is approx 25 ohms or less.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CISCOPROCESSMIB-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: SNMP), (Description: The MIB had trouble allocating memory for process name'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SGT_HDR_EXT_FIFO_OFLOW_0_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress sgt hdr ext fifo overflow on xaui-0 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_EDM-6-BAGREG_FAILED ### Response: (Severity: 6), (Category: IP), (Description: The ipv4_io process failed while attempting to register the indicated external data manager data blocks with SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls ldp igp sync delay' command in IOS XR? ### Response: The 'mpls ldp igp sync delay' command is used to configure a delay time for LDP-IGP synchronization. This delay is the amount of time LDP waits after an interface comes up before informing IGP that LDP is fully operational on that interface. This delay allows time for LDP to establish sessions and exchange labels before IGP starts using the link for forwarding. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTY-3-POOL_APPLY_FAILURE ### Response: (Severity: 3), (Category: MGBL), (Description: An unexpected error occurred when process was trying to apply vty-pool configuration. Process will abort to take process core file then restart to recover.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR* *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-TOP_SHMEM_USERS_INFO ### Response: (Severity: 6), (Category: HA), (Description: This message is emitted when system memory usage crosses a threshold in the direction of increasing memory exhaustion. The top shared memory users will follow in the next messages. There may be a memory leak or misconfiguration.), (Recommended Action: Collect the data from the following messages and attempt to determine what is driving memory usage. Forward the messages to technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_UV-3-ERR_DBG_REGISTER_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during initialization of the ospf_uv process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-5-PEER_SEND_MSG ### Response: (Severity: 5), (Category: OS), (Description: An PCE peer is either down or does not exist. Thus, the intended operation cannot be completed for this peer.), (Recommended Action: Check the state of the channel to the peer.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAP-3-FATAL_ERROR_CAPI_LEVM ### Response: (Severity: 3), (Category: INFRA), (Description: A fatal error occurred in CAPI communication. The main levm exited unexpectedly. Note the reason for the error.), (Recommended Action: Root cause of the error needs to be determined.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-3-CHIP_RESET_NOT_ALLOWED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform Fault Manager Node detects an invalid Reset action defined in the Application Fault Condition Database. An fault of severity Error is not allowed to perform a chip reset recovery action.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls traffic-eng path-selection metric' command in IOS XR? ### Response: The 'mpls traffic-eng path-selection metric' command is used to specify the metric type to use for MPLS TE tunnel path calculation. The options are IGP metric (the default), TE metric, or a combination of both. The TE metric is a user-defined metric that can be used to represent factors other than the IGP metric, such as link bandwidth or delay. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAL_IPHC-6-EA_INFO ### Response: (Severity: 6), (Category: L2), (Description: IPHC pal ea informational message), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_SCRUB_THRESH ### Response: (Severity: 1), (Category: PLATFORM), (Description: ASIC errors have occured and need memory scrubbing, such errors have crossed threshold.), (Recommended Action: Errors have been handled.Collect required information and contact TAC *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IF_UV-3-INIT ### Response: (Severity: 3), (Category: MGBL), (Description: A failure occurred during the initialization of the process. This may result in the restart of the process. The failure could be one of the following: - Event Manager - Debug Library - LWM bind Module - Sysdb verification registration - Data Storage Module - Detach pulse handler), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_BMADJ-3-ERROR_RT ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM BMADJ, error), (Recommended Action: Please collect the console log, bundle traces (show bundle trace loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_CHKPT_INSERT ### Response: (Severity: 7), (Category: FABRIC), (Description: Ingressq encountered an error during Checkpoint Insert.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-XIF_GTFF1_MEM_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected XIF GTFF1 memory multi-bit error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-MCAST_PAGE_ERR_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Multicast page error on bridge instance-0.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_ENA-3-AUTH ### Response: (Severity: 3), (Category: MGBL), (Description: Authentication related error occured or returned unexpected results.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_CHKPT_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB was unable to setup the checkpointing facility to offer high availability functionality. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-INTERNAL ### Response: (Severity: 3), (Category: L2), (Description: CPP driver failed with internal software error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-MAX_LSA_THR ### Response: (Severity: 4), (Category: ROUTING), (Description: Threshold for maximum number of non self-generated LSAs has been reached), (Recommended Action: Check if some router in the network is generating large number of LSAs as a result of misconfiguration) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-BFD_SESSION_CREATE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed to create a session with the BFD server. Retry mechanism will preriodically try to create session.), (Recommended Action: This failure may be due to lack of resources. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the failure is not due to a lack of resources seek support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-CHECKPOINT_NOT_INITIALIZED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Sync-controller is the software component which controls the synchronization devices in the system. Checkpointing is a mechanism to update the redundant RSP with the current configuration and status of the system to help takeover in case of a failover. The checkpoint mechanism needs to be initialized for Sync-controller to update the standby RSP with current frequency syncronization status. This failure could be because of memory allocation failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-7-EXTERNAL_USB_DEVICE_REMOVED ### Response: (Severity: 7), (Category: PLATFORM), (Description: platform umass media device removal is called when it detects the a device inserted in the external USB port. Inform mediasvr about External USB removal.), (Recommended Action: Debug message only. No action is required) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-4-SYSMGR_NODE_STATE ### Response: (Severity: 4), (Category: ROUTING), (Description: Sysmgr returned a failover from a node state query.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-FAILED_TO_GET_SYSCLK ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that Shelf Manger unable to sync to system clock. Shelf manager resets all per Hour/day threshold counters and valid time stamps.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-7-FREE ### Response: (Severity: 7), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-3-CANNOT_RUN_HBLOSS_SCRIPT ### Response: (Severity: 3), (Category: PLATFORM), (Description: This may be a problem with lack of resources. The heartbeat loss log won't get collected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-ERR_NO_ENCODER_DECODER ### Response: (Severity: 3), (Category: ROUTING), (Description: EIGRP could not find an encoder/decoder to be used to transmit EIGRP packets except HELLOs. EIGRP adjacency may flap if this issue is seen long enough to exhaust the maximum number of retransmissions.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between OSPF interface types - broadcast, point-to-point, and point-to-multipoint? ### Response: Broadcast interfaces (e.g., Ethernet) can reach multiple OSPF neighbors and elect a DR and BDR. Point-to-point interfaces have a single neighbor and do not elect DR or BDR. Point-to-multipoint interfaces are a collection of point-to-point interfaces on a non-broadcast network (like Frame Relay). They treat each neighbor as a separate interface and do not elect DR or BDR. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-AD9554_EEPROM_DOWNLOAD_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: AD9554 D2 clock eeprom download failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_2_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an L2VPN bridge domain MTU? ### Response: To configure the MTU for an L2VPN bridge domain, use the 'mtu' command within the bridge-domain configuration. l2vpn bridge-domain BD1 mtu 1500 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_IPC-3-SW_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An internal software error has occurred for the SIM IPC.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_SSE-3-ERR_SYSDB ### Response: (Severity: 3), (Category: L2), (Description: BFD Agent encountered a Sysdb communication failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective MSC reboot.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: attestation_app-3-INIT ### Response: (Severity: 3), (Category: INFRA), (Description: A failure occurred during the initialization of the process. This may have resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-3-LL_CFG ### Response: (Severity: 3), (Category: IP), (Description: This might result in failure generating linklocal address on certain LC.), (Recommended Action: Restarting ipv6_ma may fix this issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-CPP_LPTS_EA_REGISTER ### Response: (Severity: 3), (Category: OS), (Description: An internal cpp_lpts_ea_register function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-SUBMODESTRING ### Response: (Severity: 3), (Category: MGBL), (Description: 'The end mark is missing in the submode string. The submode is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-6-DEVICE_FORMAT_COMPLETED ### Response: (Severity: 6), (Category: MEDIA), (Description: The media storage card specified was requested to format and was formatted. See log file for specific reason.), (Recommended Action: Media storage data should be recovered from either active card or current primary mirroring device. If not redundant card or no mirroring then reinstall software and configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_IPC-3-BIND_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The error occurs due to the failure while binding the system database.), (Recommended Action: Please collect the console log and CLI output.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-4-DB_DISK_FAILURE ### Response: (Severity: 4), (Category: MGBL), (Description: Configuration manager failed to create the set of directories comprising the CFS repository under the cfs root directory. This renders the system practically unusable. The potential problems could range from no space on disk to a flawed disk.), (Recommended Action: Make sure there's enough space on disk; or if the storage media is flawed then replace it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-4-DEVCTL_ERROR ### Response: (Severity: 4), (Category: OS), (Description: devctl error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_MGR-3-LOOP_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The SVII Adjacency Manager encountered an error while waiting for an event. This should not ordinarily happen, but may indicate a temporary glitch that will automatically recover. If it occurs very frequently it may be necessary to restart the SVII Adjacency Manager process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_lite-3-ERR_SHMEM_UNAVAILABLE ### Response: (Severity: 3), (Category: L2), (Description: PPP MA has requested transfer of more interface records than shared memory can accommodate), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-UPDATE_INTF_BW_FAILURE ### Response: (Severity: 3), (Category: QOS), (Description: QoSEA encountered errors while updating the interface bandwidth of an interface in response to a bandwidth notification from IM.), (Recommended Action: If the errors are due to HW programming issues, a process restart of QoSEA process would enable QoSEA to re-attempt the programming of QoS hardware resources. If the errors are due to incompatible configuration (say, a failed QoS policy with regard to the current interface bandwdith), remove/add of the failed QoS configurations would address this error condition 'no policy-map ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-TX_ALARM_SC_SYNC_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Condition raised by BITS transmitter when internal short-circuit resistance is approx 25 ohms or less.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COMMS-3-MSG_DROPPED ### Response: (Severity: 3), (Category: L2), (Description: An incoming control message could not be fully processed. The node ID corresponding to the sender of this message could not be established. The error message string may provide further information as to the nature of the problem.), (Recommended Action: If the error message suggests a GSP error, this is a sign of a wider problem with inter-node communcation on the device - seek assistance with debugging gsp and communication issues. Gathering 'show tech-support gsp' may assist your TAC engineer with diagnosis. If the error appears transient, restarting the process which emitted this error message should result in a full resync of all data. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPPHA-3-NOCDM ### Response: (Severity: 3), (Category: L2), (Description: A CPP HA has detected that CDM is not running.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QUEUE-7-LINKED ### Response: (Severity: 7), (Category: OS), (Description: The router is running short on memory.), (Recommended Action: It may be necessary to free some memory by exiting a program. If this message recurs, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTF_EA_SHOW-7-USAGE ### Response: (Severity: 7), (Category: PLATFORM), (Description: Startup option supplied to HFR_PM_SHOW is not valid.), (Recommended Action: Please re-enter the correct option as described in the usage message 'Usage: intf_ea_show [-I ] | [-N ]' Example: sh controllers intf_ea int Ten0/2/0/0 loc 0/2/cpu0,) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCASTSN-3-NVSATOFF_QERR ### Response: (Severity: 3), (Category: L2), (Description: An error occurred when internally queueing the nV Satellite multicast offload channel events. Multicast offload will not function correctly. Remote nV satellite multicast offload states will be out of sync with the nV Host.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp snooping trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp snooping trace error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp snooping trace error verbose command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp snooping trace error verbose output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show nv satellite status command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show nv satellite status output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-SYNC_TIMER_TIMEOUT ### Response: (Severity: 4), (Category: PLATFORM), (Description: An error was encountered when any of the member racks was not in stable state before the Sync timer timeout.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-7-CFG_SIZE_LOW ### Response: (Severity: 7), (Category: SYSDB), (Description: The message to the user to indicate that the requested config size excceds the low end of the system memory limits), (Recommended Action: *RECURR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure LDP signaling for an L2VPN? ### Response: To configure LDP signaling for an L2VPN, use the 'mpls ldp' command in global configuration mode and specify the interface. mpls ldp interface GigabitEthernet0/0/0 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-6-ENFORCE_OVERAGE ### Response: (Severity: 6), (Category: LICENSE), (Description: The licensed feature is enabled in overage condition.), (Recommended Action: The customer may consider to purchase more licenses.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-5-SEU_CORR_NON_ESSEN ### Response: (Severity: 5), (Category: PLATFORM), (Description: Single event upset correction non-essential error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_DLL-4-INTR_ENABLE_FAIL ### Response: (Severity: 4), (Category: FABRIC), (Description: Hardware state is not correct.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-6-SVI_OOR ### Response: (Severity: 6), (Category: ROUTING), (Description: L3 EM Table OOR during l3if creation event), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEATURE_AGENT-4-INVALID_DESCENDANT ### Response: (Severity: 4), (Category: INFRA), (Description: Features are organized in a tree, and the identified features do not meet relationship requirement. This is an internal software error, and as a consequence, feature capability information may not be available.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_CERR_REGISTER_DLL ### Response: (Severity: 3), (Category: OS), (Description: The call register the dll using cerr_register_dll failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-4-ADD_SLICE ### Response: (Severity: 4), (Category: OS), (Description: The PA failed to assign an IFIB slice.), (Recommended Action: Restarting lpts_pa may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_MAIN-5-CLOCK_ACCURACY_ENHANCED ### Response: (Severity: 5), (Category: PLATFORM), (Description: The system timing is switching to enhanced accuracy mode as a result of applying the 'timing-accuracy enhanced' configuration. This switching operation may result in a transient flap in timing (PTP/SyncE) or in the PLL states. This is an expected behaviour and no further action is needed from the user.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_3_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlea-4-NODE_MAC_ENTRY_LIMIT_HIT ### Response: (Severity: 4), (Category: L2), (Description: The VLAN EA process added an underlying member to an interface, and as a result of this, passed the node level limit for MAC accounting entries. No more entries will be accepted on this node until some of the existing entries are cleared. It is also possible that some existing MAC accounting entries may not be correctly programmed on all members.), (Recommended Action: As this message indicates a resource limit has been hit, it can potentially be alleviated by removing a bundle member or reducing the number of layer 2 peer devices. A support request should only be raised if the cause for this message is not apparent. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP bias greater than or equal to the high bias alarm threshold. The CFP is the pluggable optics on the line cards. The bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCCLASS-3-CONSUMER_RCV_BUF ### Response: (Severity: 3), (Category: MGBL), (Description: The consumer finds one or more invalid fields in the buffer received from the producer.Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-GST_SYNC_ERR_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: GST Sync error on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-PROC_CNT_NORMAL ### Response: (Severity: 3), (Category: HA), (Description: When number of processes are below MINOR Threshold Percentage), (Recommended Action: Not required) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-IDT_XFORM_COMPLETED ### Response: (Severity: 7), (Category: HA), (Description: --), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-PROFILE_INACTIVE ### Response: (Severity: 4), (Category: PLATFORM), (Description: A memory resource profile has been configured for the system using '(admin-config)#hw-module profile <>'. However, this profile has not been activated on the line card that originated the warning message. Use '#show hw-module profile <> location X/Y/cpu0' to see what profiles are currently active on the line card.), (Recommended Action: Either the line card that originated the warning message must be reloaded in order to activate the configured memory resource profile on that card or the entire system must be reloaded. Consult the warning message for instructions.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-7-ERR_SYSMGR ### Response: (Severity: 7), (Category: FABRIC), (Description: The FGID-DB server failed in sysmgr API), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-INCOMPATIBLE_LC_FOR_CHASSIS ### Response: (Severity: 3), (Category: PLATFORM), (Description: This LC type is not supported in this chassis type for the ASR9K family of chassis as it is incompatible to the chassis hardware architecture for traffic carrying purposes. Shelf manager raises this alarm when it detects the presence of the incompatible LC and clears the alarm when the LC is no longer seen as being present.), (Recommended Action: Please remove this LC from the chassis and replace it with another LC type which is supported in the chassis according to the Cisco user documentation. If you have questions, please contact your Cisco technical representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBDLLMGR-4-UNEXPECTED_MAGIC ### Response: (Severity: 4), (Category: OS), (Description: An unexpected magic number encountered. This is not necessarily an error.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp update-delay' command in IOS XR BGP configuration? ### Response: The 'bgp update-delay' command is used to configure the maximum time that BGP will delay sending updates to neighbors after the BGP process starts. By default, when the BGP process starts, it immediately sends out updates to all neighbors. In a large network, this can result in a significant amount of processing on the neighbors. The update delay allows the BGP process to stagger the sending of updates, reducing the processing load on the neighbors. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_IN_MEM_CORR_ECC_ERROR_LNK1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast input memory correctable ECC error on link 1), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-3-INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: An attempt to initialize a component failed. The error message describes the error, provides an error code and a string interpretation of the error code.), (Recommended Action: Please try to recover by doing the process restart of the process that generated the error. If that fails, please try to reload line card using CLI 'hw-mod loc <> reload'. If the issue persists, collect console log and the following information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - sh platform - sh install summary - sh version - show tech-support ethernet interfaces - show tech-support location <> file <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RUNTIME-6-SIGNAL ### Response: (Severity: 6), (Category: OS), (Description: Signal handler information is displayed), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-7-INVALID_IP ### Response: (Severity: 7), (Category: SERVICES), (Description: The ip address is invalid.), (Recommended Action: Please configure proper valid IP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IEP-3-DAEMON_ERR_EVM_EVENT_BLOCK ### Response: (Severity: 3), (Category: IP), (Description: An error occurred while using the process event manager.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-RX_ALARM_AIS ### Response: (Severity: 3), (Category: PLATFORM), (Description: The BITS receiver has detected AIS defect for incoming signal. AIS is usually an unframed all-ones signal. For T1 mode AIS is declared when the BITS receiver detects four or fewer zeroes in a 3ms period. For E1 mode AIS is declared when the BITS receiver detects fewer than three zeroes in two E1 frames.), (Recommended Action: 1) Ensure framing format on port matches framing format on the line. 2) Trace and check the source of AIS signal. Possibly an incorrect internal configuration in the service provider equipment, or a failure in their upstream connections.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-NT_SWO_REDUNDANCY_NOT_READY ### Response: (Severity: 3), (Category: INFRA), (Description: The Ethernet Switch Driver instance attempted to start a protocol thread which monitors its peer process's health on the adjacent SC. The protocol thread exchanges protocol packets with its peer via scratch registers on the PCIe switch. A write and subsequent read attempts to the PCIe switch scratch registers have failed, which prevent the protocol thread from starting. As a result the Switch Card redundancy can't be supported at this time. The Ethernet Switch Driver will continue to try this operation and when the write/read/Verify operation succeeds, the protocol thread will start and Ethernet Switch Card redundancy will be available at that time.), (Recommended Action: Check if the ESD instance on the peer SC card has exited or crashed. Reload of the Switch Card may be required to recover from this condition.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-7-CAL_CHIP_READ_CONF_REG ### Response: (Severity: 7), (Category: MGBL), (Description: Reading value of RTC config register.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-ALLOCFAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Allocation of the specified resource failed, probably due to low memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-FSMTIMEOUT_RESET ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is not able to boot up), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_NPMB-3-NETWORK_START_FAIL ### Response: (Severity: 3), (Category: OS), (Description: This failure encountered when the network start of packet couldnot be obtained.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_LCP-3-MTU_UNUSABLE ### Response: (Severity: 3), (Category: L2), (Description: PPP has been informed that the lower-layer MTU has been set to a value smaller than the PPP header size, which makes it impossible for PPP to operate.), (Recommended Action: Reconfigure the interface's MTU to a larger value. In order to ensure correct operation with peers, values which provide a layer 2 payload capacity (after allowing for 4 bytes of PPP header) of 1500 bytes or greater are required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-6-MLACP_INVALID_PRIORITY_REQUEST ### Response: (Severity: 6), (Category: L2), (Description: An mLACP peer device has requested that the priority of the specified member be changed. This is currently an invalid operation due to the reason specified. If the message indicates that the priority request has been ignored, then the peer will be notified that the priority change has not been made.), (Recommended Action: Check that the configuration of all the mLACP peer devices is consistent.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-FIFO_1_OFLOW_NPU2BR_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: FIFO-1 NPU to bridge instance-2 overflow.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WD_DISKMON_SYSADMIN-5-SYSCALL ### Response: (Severity: 5), (Category: INFRA), (Description: A system call failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_LQ_FULL_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue full error on XAUI 1 LQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-RELIABILITY_INVALID_REPORT_TYPE ### Response: (Severity: 4), (Category: L2), (Description: The report type of the message received was inappropriate relative to the interface's protocol state. For example, receiving an 'E-LMI Check' while processing a 'Full' STATUS report. This indicates that the last PDU sent to the peer device was not received.), (Recommended Action: Check that E-LMI is configured on the peer device and that the link to the peer device is functionining correctly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_L2TP-7-DEBUG_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB L2TP component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-SYSDB_APPLY ### Response: (Severity: 4), (Category: OS), (Description: Error in apply handler. This will impact the dumper.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. admin show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-SIGNAL_UPDATE_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The Frequency Synchronization manager that generated the message failed to update its database, either in response to a message received from a remote Frequency Synchronization manager on another node, or after a change to the selected inputs in another selection point on this node. This is most likely due to an out-of-resource condition. The corresponding frequency signal will not be used.), (Recommended Action: Resolve the underlying resource issue, then restart the Frequency Synchronization manager on the affected node using the following command: process restart fsyncmgr location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-RSI ### Response: (Severity: 3), (Category: ROUTING), (Description: A call to an external event manager function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-2-FPD_FPGA_LOAD_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: One of more FPGAs on the RSP has failed to load the latest image.), (Recommended Action: Upgrade FPDs using upgrade hw-module FPD command. Reset the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POS-4-PORT_NOT_FOUND ### Response: (Severity: 4), (Category: L2), (Description: A 'port available' notification was received by the POS Interface driver from the G-POS library for a port that is not known about.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PA_FF-4-EVENT_BLOCK ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when block waiting for Event Manager events.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_AGORA_ALM_TYPE_ONE ### Response: (Severity: 2), (Category: PLATFORM), (Description: AGORA type one alarm.), (Recommended Action: If the problem persists, call your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFL-3-ERR_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failure to create an OBFL record. This may indicate a problem with the OBFL storage device.), (Recommended Action: Ensure that the OBFL storage device is available and properly formatted. To format the OBFL storage device, use the 'format' command as specified in the 'File System Commands' section of the ASR9k User's Guide.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_1_PKT_MINLEN_ERR_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet minimum length error on NPU-1 interface on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LIC_MGR-6-EVENT_ERR ### Response: (Severity: 6), (Category: OS), (Description: An error has occured in attempting to handle an event sent to the IOS XRv license manager. The event has been ignored.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different ways to filter BGP routes on IOS? ### Response: BGP routes can be filtered on IOS using\n- AS path access lists to filter based on AS path\n- Distribute lists to filter based on prefix\n- Prefix lists to filter based on prefix\n- Route maps to apply complex filtering logic\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-AD9554_ACCESS_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: AD9554 access failure/success.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-EA_RETRY_FAILED ### Response: (Severity: 3), (Category: FORWARDING), (Description: The Tunnel-IP EA has failed to program a tunnel interface after 1 or more retries.), (Recommended Action: Shut and no shut the tunnel interface. If the problem persists, remove and re-configure the tunnel interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-INSTALL_FORCE_OP_FAILURE_RELOAD ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that install replace commit has failed during activation due to which system is being reloaded to auto-recover.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-7-INIT_FAILED ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: NetIO process has problem initializing its database and attempts to restart in an attempt to recover from the error.), (Recommended Action: The process attempts to restart on detecting this failure, in an effort to recover from the failure. If after restart things recover, then nothing more needs to be done. If the error is seen when the system is low on system resources, once the system resource like memory, cpu go back to normal state, the process should succeed in coming back up. If the process fails to recover and repeatedly exits then the ios message will have the details of what part of initialization failed and the reason for it, for further action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBMA-2-SVC_CRIT ### Response: (Severity: 2), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-6-TRANSFER_DONE ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Package transfer requested on this satellite has completed. Run 'show nv satellite status' for more information.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-PROCESS_OPTIONS_INIT_FAILURE ### Response: (Severity: 4), (Category: OS), (Description: Dumper failed to initialize process core options database.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_IM ### Response: (Severity: 3), (Category: ROUTING), (Description: Interface Manager returned an error during a tunnel interface operation. The system internal tunnel status might now be inconsistent which might prevent the tunnel from coming up or traffic flowing over this tunnel to be dropped.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. 1. To determine if the system is in an inconsistent state following this error, verify the TE tunnel is present in: configuration, TE and Interface Manager: -show run interface tunnel-te -show mpls traffic-eng tunnels -show interfaces tunnel-te If the tunnel is present in some of these commands but not in others, the system is in an inconsistent state. 2. Collect: -show configuration commit failed -show logging -show tech-support mpls traffic-eng -show tech-support pfi for further analysis of the issue. 3. The te_control process may be restarted in order attempt recovery from this situation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AHCI-2-DEV_HD0_NOT_RESPONDING ### Response: (Severity: 2), (Category: PLATFORM), (Description: SATA HD0 device not responding), (Recommended Action: Please attempt the following: If dual RSP, and the problem is on the active RSP, issue 'redundancy switchover' If the problem is on the standby/simplex RSP: Restart low level ahci driver via ksh, 'process restart devb-ahci' Failing which, Reload RSP If problem persists, SATA HD0 devices have to be replaced If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSDIR-4-OPERATION_QS_ABORT_DONE ### Response: (Severity: 4), (Category: INSTALL), (Description: The Quickstart has successfully executed its abort procedure and will hold on to the new instances until told otherwise for triage purposes.), (Recommended Action: The system has been held following an operation abort to allow system level triage. When complete, issue command install activate fast cleanup to clean the system up and make it ready for another fast upgrade.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-HW_DETECTED_ERROR_PORT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cpuctrl driver HW error interrupt handler was invoked and found a port with valid isn error registers.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_3_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature less than or equal to the low temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CPAK with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-CHKPT_RESTORE_DATA ### Response: (Severity: 3), (Category: OS), (Description: nrs_chm_chkpt_create_data failed while restoring the data handles from the chkpt shared memory after nrs server process restarts.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFLX_LIB_MGR-3-PTFM_MAX_INTF_ERR ### Response: (Severity: 3), (Category: SERVICES), (Description: The Interflex Manager failed to get max number of interfaces from platform at startup. The process will be automatically restarted, if it keeps restarting with same message *DDTS*), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_MEM_ALLOC ### Response: (Severity: 4), (Category: L2), (Description: The process failed to allocate memory for the specified resource.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_4_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_4 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_TX_FIFO_OFLOW_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI interface to NPU-0 reported tx fifo overflow on bridge instance - 1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_LIB-4-CLIENT_ERROR ### Response: (Severity: 4), (Category: INSTALL), (Description: A client of the Install infrastructure unexpectedly returned an error during processing, and so the requested operation may not be completed.), (Recommended Action: One of the local nodes returned an error for an install verify request. Please check the state of all the nodes and retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_12_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_12 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TTI_MISMATCH_DEMA ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSHD-3-ERR_AUTH ### Response: (Severity: 3), (Category: IP), (Description: Kerberos authentication failed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-INVALID_UNPROV_MSG ### Response: (Severity: 3), (Category: OS), (Description: The virtual service unprovision message was received, however, the data it contained could not be interpreted.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation followed by deactivation and then unprovision of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-3-ROUTE_UPDATE_UNSUPP_PROTECTION ### Response: (Severity: 3), (Category: ROUTING), (Description: In deployments in which Remote LFA FRR is not supported or in which a specific flavour of protection is not supported, IGP should not be computing such primary/remote-backup path.), (Recommended Action: Debug respective IGP generating the route update and fix the topology/configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-ERR_USAGE ### Response: (Severity: 7), (Category: OS), (Description: usage error.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-3-MALLOC_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The requested operation could not be accomplished because of a low memory condition.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-GSP_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: --), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EES-6-PROC_RESTART ### Response: (Severity: 6), (Category: PLATFORM), (Description: EES communication channel got stuck process self restart to recover from the condition.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFEA_MPLS_EA-3-ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: AFEA MPLS-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MVRP-4-L2VPN_FLUSH ### Response: (Severity: 4), (Category: L2), (Description: The MVRP IO process has failed to initiate VLAN ID flush with L2VPN after five seconds of retrying. Further retries will be attempted every 3 seconds. Until the flush succeeds the currently registered VLAN IDs may be inconsistent.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-MIB_INDEX_CHKPT_FAIL ### Response: (Severity: 4), (Category: L2), (Description: An error was encountered while checkpointing Frequency Synchronization MIB indices. Frequency Synchronziation SNMP data may be inconsistent over Frequency Synchronization process restart or ISSU.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_SDFEC_LOF ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_SIS-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Service Interface Server encountered a fatal error and is not able to recover from the error. A text reason and error number will be supplied to describe the error.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect 'show log location ' output, and 'show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-7-LOCK ### Response: (Severity: 7), (Category: OS), (Description: --), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-BADCLASS ### Response: (Severity: 4), (Category: MGBL), (Description: An invalid class name was entered either by itself or as part of a hierarchy string.), (Recommended Action: Use the classinfo command to get more information about available class names. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_PLATFORM_IFNAME_PARSE ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA encountered an error using a platform API to parse the interface name. The error message describes what operation has failed and why it failed. The error is most likely caused by a programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-3-RACK_DOWN ### Response: (Severity: 3), (Category: PLATFORM), (Description: This indicates that either the rack is powerdown/shutdown or there is some problem with control ethernet cables or switches between the racks.), (Recommended Action: If the rack is not powerdown or shutdown by the operator, then check the control ethernet connectivity between racks. (Check if the cables are okay and also if the switch is operating normally). Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-GROUP_NOTIFY ### Response: (Severity: 3), (Category: OS), (Description: Unable to set group notify for PLACEMENT_GSP_GROUP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-BUNDLE_INVALID_PIPELINE ### Response: (Severity: 3), (Category: L2), (Description: Unable to add bundle interface to logical switch with specific pipeline id.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-STARTTRANS ### Response: (Severity: 4), (Category: MGBL), (Description: An error occurred invoking an MDA function. This could be because the timeout time was not correctly entered. The details are in the error string.), (Recommended Action: Check that the format of the timeout time is correct. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-EG_FBU_POOL_EMPTY ### Response: (Severity: 3), (Category: PLATFORM), (Description: NP detects EG_FBU_POOL_EMPTY and reported through interrupts), (Recommended Action: No specific actions needed. The software should be able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HORSE-2-ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Error in HORSE operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_CRP-3-INIT_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: autorp_candidate_rp failed to initialize successfully.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show processes autorp_candidate_rp detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes autorp_candidate_rp detail output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp candidate-rp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp candidate-rp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging process autorp_candidate_rp error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging process autorp_candidate_rp error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-MESSAGE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The error occurs,if the provided source or destination ip address is invalid.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all loc <>), show cef platform services resource oor common loc show cef platform services resource shm-objects common loc show cef platform services trace common all reverse loc show cef platform services trace common errors reverse Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_TDM-7-OBJ_LEN ### Response: (Severity: 7), (Category: HA), (Description: An object save or get operation is being done with the wrong length buffer. This points to a logical bug in the client application.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the preferred method for upgrading an IOS XR router to a new release? ### Response: The preferred method for upgrading an IOS XR router to a new release is using the mini.pie file, rather than TURBOBOOT. This involves the least amount of service interruption. The upgrade is performed using the 'install add' and 'install activate' commands in admin mode. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EM-7-FMS_EVM_INIT_EVENT ### Response: (Severity: 7), (Category: HA), (Description: The event_init_event function reported an error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_BCDL_CONSUMER-3-ERR_FDI_CLIENT_REG ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID BCDL Consumer was unable to register with the FDI client. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-UPGRADE_NOT_SUPPORTED ### Response: (Severity: 3), (Category: DRIVER), (Description: The indicated FPD upgrade is not supported on this platform due to the reason displayed by the platform error message.), (Recommended Action: Follow the platform message to enable the FPD upgrade on this platform) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BULKSTAT-3-TOOSMALL_BUFFER ### Response: (Severity: 3), (Category: SNMP), (Description: The buffer size is insufficient to accommodate the header for the bulk data file. The header contains the schema definitions of all the configured schemas.), (Recommended Action: Increase the maximum buffer size using the buffer-size size-of-buffer command, where size-of-buffer is the increased buffer size.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESDMA-6-ESD_CONN_LOST ### Response: (Severity: 6), (Category: INFRA), (Description: ESD on the given location has restarted or stoped. Hence connection between ESD and ESDMA has been lost.), (Recommended Action: Check on the esd process in the given location) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-EVENT ### Response: (Severity: 4), (Category: L2), (Description: ELMI encountered an error using the Event Manager library. The error message describes what operation has failed and why it failed. The most likely reason for this is a low memory resources or programming error.), (Recommended Action: Consider restarting the ELMI process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-6-INFO_MSG ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is a informational message in the NP Driver to indicate an operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-ACQUIRE_LOCK_FAILED ### Response: (Severity: 3), (Category: L2), (Description: CPP driver failed to acquire shared memory lock.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-2-MANDATORY_REBOOT ### Response: (Severity: 2), (Category: PLATFORM), (Description: prm_server process respawn is not supported, hence reboot node if prm_server respawned/crashed), (Recommended Action: Reboot the Node if it hasn't rebooted on its own, otherwise no action needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-AD9554_PLL_LOL ### Response: (Severity: 3), (Category: PLATFORM), (Description: AD9554 PLL loss of lock detected/cleared), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VASI_EA-3-LINK_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: An error occurred while attempting to join together the two halves of some VASI pairs on the specified node. The pairs will not come up. If there is a standby node configured for the pairs, they may come up on the standby.), (Recommended Action: It may help to shut down, then bring up, the VASI interface pairs in question.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRP_UPGRADE-3-WAITPID_RM ### Response: (Severity: 3), (Category: MGBL), (Description: waitpid for the 'rm' process failed. Configuration removal thread terminated incorrectly.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_PFI-3-INFRA_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This error is an internal infra error and when critical is handled accordingly in the code. The context of the error is provided in the actual code where this error is used. Some of the error conditions that are encountered under this is bind failure, attr query failure, set/get failures, etc. If this error is seen persistently initiate the recommended action.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_MEAS-4-LINK_BURST_INTERVAL_STRETCHING_ACTIVE ### Response: (Severity: 4), (Category: ROUTING), (Description: The requested PPS of interface sessions is more than can be supported. The configured burst interval will be increased to ensure probe packets sent per second do not exceed the maximum allowed PPS. The LINK_BURST_INTVL_STRECTHING_INACTIVE syslog will be issued once this condition is cleared.), (Recommended Action: Configure a larger Interface delay measurement burst interval.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-6-DSC_CHANGE_EVENT ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an information log.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHER-3-BDL_IIR_OP_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The ethernet driver failed to process a bundle IIR notification message. Further it is not able to propagate the message back to the virtual interface owner, and hence it is possible that the Ether basecaps is out of step with the bundle configuration.), (Recommended Action: Restart the ether_caps_partner process in an attempt to recover, or if this fails, detach and re-attach the physical member interface that the error was reported on by unconfiguring and reconfiguring the bundle member id.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-2-LC_POWER_NOT_READY ### Response: (Severity: 2), (Category: PLATFORM), (Description: LC power not ready.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SEG_HDR_FIFO_OFLOW_0_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress seg hdr fifo overflow on xaui-0 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_HQ_PKT_LEN_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue packet length error on XAUI 1 HQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-4-OIR ### Response: (Severity: 4), (Category: PLATFORM), (Description: 'The power-module has either been pulled/inserted.'), (Recommended Action: 'Verify if the power-module has been plugged/removed.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_IPV4_EA-3-ERROR2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: DNX IPV4-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-NO_REDISTMETRIC ### Response: (Severity: 3), (Category: ROUTING), (Description: Metric is not configured during redistribution.), (Recommended Action: Configure the metric needed for redistribution using default-metric or route policies.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-4-ASIC_TEMP_NOT_VALID ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_MPLS_EA-3-ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: DNX MPLS-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-6-ENFORCE_OVERAGE ### Response: (Severity: 6), (Category: LICENSE), (Description: The licensed feature is enabled in overage condition.), (Recommended Action: The customer may consider to purchase more licenses.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_EXEC-6-ACCESS_DENIED ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-CFP_INFO ### Response: (Severity: 4), (Category: L2), (Description: An issue is detected during operation on Optic interface module. %d - port number. %s - description of the operation. %s - description of the issue. %s - reason for the issue), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RVM_MGR-3-LVM_CREATE_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: LVM create failure.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSA-3-ERR_CLEAR_FSTATS ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric Plane Statistics CLI encountered an error in trying to clear the fabric plane statistics as a result of sysdb call failure. This software error will cause the following fabric plane statistics getting appended to the previous ones. No other system functionality will get affected due to this.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-IDT_PLL_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: IDT Rx PLL loss of lock and loss of signal interrupt), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-3-NULL_SHIM_INFO ### Response: (Severity: 3), (Category: L2), (Description: Null shim info encountered for given interface handle), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-5-UNABLE_TO_START_USB_MEDIASVR_THREAD ### Response: (Severity: 5), (Category: PLATFORM), (Description: Start disk space monitoring for nodes which need. This notice message will get printed when it unable to start mediasvr thread.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_TCAM_ODS_DESTROY ### Response: (Severity: 3), (Category: OS), (Description: TCAM ods destroy error.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of virtual links in OSPF? ### Response: Virtual links are used to connect an area that does not have a direct physical connection to the backbone (Area 0). The virtual link provides a logical path to the backbone through another area. This is commonly used if a new area is introduced that cannot have a direct link to the backbone. The virtual link is configured on the Area Border Routers (ABRs) on both ends of the link. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-3-INIT ### Response: (Severity: 3), (Category: LICENSE), (Description: The license manager encountered a error condition while initializing. The condition where the error occur is failure in setting up event Handler of eventing IPC , other is failure in adopting the Role state of Dsc or non-Dsc. The restart of licmgr or node reload should likely resolve the issue.), (Recommended Action: Please restart the licmgr process command 'admin process restart licmgr'. Another option is reloading the RP card by command 'admin reload'. If the error log message is reoccuring , please collect informaiton using the commands 'show tech-support license ','show license trace platform' and contact your tech support representative and provide them the collected information and exact message as displayed on screen.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-ESMC_SEND_TIMER ### Response: (Severity: 3), (Category: L2), (Description: An error occurred when attempting to re-arm the ESMC SSM send timer. No further SSMs will be sent from interfaces on the card on which this message was seen.), (Recommended Action: Restarting fsyncmgr on the card on which this message was seen may fix the problem. If the message continues to be seen, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_DRIVER-2-HW_ERR ### Response: (Severity: 2), (Category: L2), (Description: Driver HW error interrupt occurs, it will cause HW reset.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-EVAL_EXPIRED ### Response: (Severity: 3), (Category: LICENSE), (Description: Your evaluation period has expired. Please obtain a new idToken from the Smart Agent Portal and re-register the device.), (Recommended Action: Customer needs to obtain a new ID token from the smart agent portal and re-register the device with the Cisco licensing service.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_FPD-5-OFFLINE_NOTICE ### Response: (Severity: 5), (Category: L2), (Description: An attempt has been made to temporarily change the operaional status of the SPA from online to offline before the image for the FPD could be updated on the target SPA. For some SPA types, this operation is required.), (Recommended Action: Ensure that you have redirected the traffic of the target SPA before performing this action, since the target SPA will require a power cycle operation after the image update for the FPD on the target SPA has been performed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Embedded Packet Capture (EPC) feature in Cisco IOS XR? ### Response: The Embedded Packet Capture (EPC) feature in Cisco IOS XR allows capturing packets that are received or sent on an interface. It helps in troubleshooting network issues by analyzing the captured packets. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-LTRACE_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: Initialization of trace functionality for exec shell failed. This would affect the debugging of exec shell.), (Recommended Action: Try logging out and login again. If the message appears again, copy and save the message. Collect show logging output and any other suspicious error messages on console and inform technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_BMADJ-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM BMADJ, error), (Recommended Action: Please collect the console log, bundle traces (show bundle trace loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-4-WARNING_FIPS ### Response: (Severity: 4), (Category: SECURITY), (Description: The sshd encountered a warning condition.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_9_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_SDFEC_OOM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPPIF-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A run time error occurred during the lc idb operation on the linecard. The reason for the error is dispalyed. Please call Cisco Support with the error information), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND_LITE-3-SHMEM_MUNMAP_FAIL ### Response: (Severity: 3), (Category: L3), (Description: A failure has occured in unmapping a shared memory region required for communication between the IPv6 Neighbor Discovery (ND) process (ipv6_nd) and the ND spoofing process (ipv6nd_lite). This error alone will not prevent the router from working, but since ipv6nd_lite is used to maintain service during restarts of ipv6_nd, it may cause the router to become momentarily unreachable by other routers during restart.), (Recommended Action: Check that the ipv6nd_lite process is running and restart it if necessary. Look for other error messages that may help explain the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_1_ERR1_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 1 ran into error-1 on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-CHASSIS_IDPROM_READ ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC driver was not able to retrieve a valid chassis IDPROM image from backplane. This failure will prevent applications that requires a valid chassis serial number from operating correctly.), (Recommended Action: Perform RP fail over to see if the other RP has the same problem. If problem persist, try to power-cycle the chassis to recover from the failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: Serial-3-MTU_IMPOSE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The specified MTU could not be applied on this interface.), (Recommended Action: User should choose a more apporpriate MTU value which is neither too small nor too large for any configured protocol.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-CGM_INIT ### Response: (Severity: 3), (Category: OS), (Description: An internal cgm_init function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: YANG-6-INFO ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POS-4-LOST_EVENT ### Response: (Severity: 4), (Category: L2), (Description: The specified process failed to receive an event that was sent to it.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRG-5-ROLE_MASTER ### Response: (Severity: 5), (Category: SUBSCRIBER), (Description: The SRG role from the concerned group has change to MASTER from either SLAVE or uninitialized role. This is a normal redundancy event.), (Recommended Action: None required if there has been any network event or administrative action that caused this redundancy role change. Subscriber status may be checked on the master and slave routers to verify consistency, if desired.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FM-4-INVALID_ARGS ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Internal error. Function was passed an Invalid Parameter.), (Recommended Action: please check if the process is blocked using 'show process blocked'. Then restart the lpts_fm. If the problem still exists, copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PA_FF-3-MALLOC ### Response: (Severity: 3), (Category: OS), (Description: An attempt to allocate meory failed.), (Recommended Action: Please check there are no memory leaks using the following commands: - show memory compare start - show memory compare end - show memory compare report) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_MCAST-3-ERR_LINECARD ### Response: (Severity: 3), (Category: PLATFORM), (Description: An internal error occurred in MPLS which involves forwarding for mpls p2mp packets.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, and collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>), 'show install active', 'show logging console', 'show platform' and 'show version'. Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BIOS_FPD-3-BACKUP_BIOS_LOADED ### Response: (Severity: 3), (Category: DRIVER), (Description: The Backup BIOS images on BIOS SPI Flash has been loaded on the indicated card. The output of 'show hw-module fpd' will show the affected images with BACK IMG state. This can happens when Primary BIOS Flash is corrupted, so it fallback to load the backup image set to recover from the failure.), (Recommended Action: Although the system will continue to run, the backup image set might be of older version and it might have known issues that have been fixed on latest version. So it is critical to address the problem as soon as possible. The output of 'show hw-module location fpd' will identify the image with the problem with NEED UPGD state and it will have missing Programmed version. To correct the problem, use the 'upgrade hw-module location fpd ' command to re-program the FPD image and power-cycle the affected card for BIOS to load with the upgraded image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-SHUTDOWN_START ### Response: (Severity: 4), (Category: PLATFORM), (Description: Unrecoverable error detected on the Network Processor, NP shutdown started), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSLA-4-ERR_OPER ### Response: (Severity: 4), (Category: MGBL), (Description: IPSLA operation module has failed to perform an operation.), (Recommended Action: See the message text for details of failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGEDM-3-FAILEDREGEXEC ### Response: (Severity: 3), (Category: MGBL), (Description: 'Regular expression match failed with the reason mentioned in the message. This may lead to wrong 'show config failed' listing.'), (Recommended Action: Please contact TAC with the output of the following commands: - console logs - show version - show process nvgen_server - show nvgen trace ascii-backup reverse - show configuration history If the error recurs frequently, it may be possible to rectify it by restarting 'nvgen_server' process. But please collect the logs mentioned above, before restarting the process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-MANDATORY_REBOOT_OVERRIDE ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-2-CANBUS_READ_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: PRM was not able to read memory characteristics via canbus.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-2-ERR_MEM_ALLOC ### Response: (Severity: 2), (Category: ROUTING), (Description: The requested operation could not be accomplished because of a low memory condition. BGP may not operate correctly until the process is restarted.), (Recommended Action: Reduce other system activity to ease memory demands, then restart the process. If conditions warrant, upgrade to a larger memory configuration. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBSOC-5-SVC_NOTICE ### Response: (Severity: 5), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlma-6-UNKNOWN_NODE_VLAN_LIMIT ### Response: (Severity: 6), (Category: L2), (Description: A failure occurred while trying to determine the maximum number of VLAN sub-interfaces that can be supported on the given node. The system may allow configuration of more VLAN sub-interfaces that can be supported, or may not allow the full number supported to be configured.), (Recommended Action: After gathering the information specified, it may help to restart the VLAN MA process on the affected node, with proc restart vlan_ma location [location]. If this restart completes without the message appearing again, the problem has been resolved. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGPTE_LIB-3-ERR_BAG_REGISTER ### Response: (Severity: 3), (Category: ROUTING), (Description: IGP failed to register its bag files with the bag library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTR6 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_TCAM_ODS_RD_IDS ### Response: (Severity: 3), (Category: OS), (Description: TCAM ods destroy error.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-MIPC_NOTIF_ACK ### Response: (Severity: 4), (Category: OS), (Description: It is an internal error which the system failed to acknowledge a MIPC Server notification.When this issue happens, it will trigger an automatic restart of pifibm_server_lc process.), (Recommended Action: Check the status of Metro IPC Server because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-ACTIVE_LSP_SWITCH ### Response: (Severity: 5), (Category: ROUTING), (Description: The Active LSP on the specified tunnel interface has changed.), (Recommended Action: None. This is a solicited message (by 'logging event lsp-status' \ ' switch-over' interface configuration) and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-PKT_LEN_ERR_1_FIA_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet length error from FIA for NPU-1 on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-SYSDB_BIND_ERR ### Response: (Severity: 3), (Category: L2), (Description: Some error occured in sysdb bind operation bind. The text of the message displays the failed operation for the bindpoint with error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_LIB-4-CLOCK_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: The infrastructure is behaving incorrectly. This will not affect the operation of the MBI infrastructure, but messages and logs may not contain timestamps.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-6-OUT_OF_MEMORY ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: IM was unable to allocate the memory it needed - indicating the system is in a very low-memory condition, which should be recovered by wdsysmon automatically. IM will exit and restart in an effort to help clear the low memory condition), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERROR_NOT_SUPP ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, feature not supported), (Recommended Action: This error is expected since the feature or the scale being configured is not supported. If you believe there is still some problem, please collect FIB platform trace (show cef platform trace all all loc <>), 'show install active', 'show version', 'show platform' and 'show console logging' output. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-3-TSP_GST_TIMEOUT ### Response: (Severity: 3), (Category: PLATFORM), (Description: TSP GST timeout.), (Recommended Action: Minor error, no action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-CANT_RMDIR ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the infrastructure is behaving incorrectly. The Package infrastructure could not remove a required directory, so processing of the current operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT_SWITCH-3-LINK_FAIL_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: PUNT link has failed.), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ILITE-3-UNKNOWN_ASIC_INDEX ### Response: (Severity: 3), (Category: PLATFORM), (Description: The asic index is unknown, this may be a program level error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_TOO_MANY_PATHS ### Response: (Severity: 3), (Category: ROUTING), (Description: The maximum allowed number of next-hop paths for a single destination prefix has been exceeded. One or more paths have not been installed in the RIB, and should be removed from the running configuration.), (Recommended Action: Excess next-hop paths should be removed from the running configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-MDR_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_OUT_MEM_CORR_ECC_ERROR_LNK0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast output memory correctable ECC error on link 0), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-SYSDBREG ### Response: (Severity: 4), (Category: LICENSE), (Description: An error occurred when registering with the system database), (Recommended Action: please restart the licmgr process command 'admin process restart licmgr'. If the problem is still not resolved , please collect informaiton using the commands 'show tech-support license ','show license trace platform' and contact your tech support representative and provide them the collected information and exact message as displayed on screen.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCT_SVR-3-INIT ### Response: (Severity: 3), (Category: L2), (Description: The process acct_svr encountered a software error while initializing. The process is exiting and will be restarted. System will not be affected.), (Recommended Action: show accounting trace location X/X/X) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_VCM_EA-2-INTERNAL_MSG ### Response: (Severity: 2), (Category: L2), (Description: An internal error occurred in VCM_EA while executing one of the following operations: - Capsulation addition - Capsulation removal - Virtual Circuit Interface creation - Interface Manager operation), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_MEM_ALLOC_ARM_IDB ### Response: (Severity: 3), (Category: ROUTING), (Description: These are unexpected errors), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-SUSPENSION_STOP_REQUEST_RECEIVED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-CREATE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: CPP driver failed to to create device.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-BA_UNSPEC_FAIL_14 ### Response: (Severity: 3), (Category: IP), (Description: Binding corresponding to the received PBU does not exist. A PBU with HI value as specified in the error message expects a binding to be present.), (Recommended Action: Ignore this error message if it occurs only a few times. If the error persists, then do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2VPN_FGID-6-TIMER_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The specified timer failed to start.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-EXIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-2-PLATFORM_ERROR ### Response: (Severity: 2), (Category: LICENSE), (Description: Smart Licensing Agent has encountered a Platform Problem. The Platform Development Team needs to be contacted to get this problem addressed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_FPGA-1-ERR_HW_ERR_THRESHOLD_RELOAD ### Response: (Severity: 1), (Category: L2), (Description: A hardware error reached threshold on the Datapath FPGA. Software will take action as described in the error message to try to recover from the error. The hardware error and the software recovery action will cause linecard reload. Device: %s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Software action: %s - the action that software will take to try to recover from the error.), (Recommended Action: If the message recurs, diagnostics should be executed on the PLIM and MSC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_7_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-3-FSDB_FAB_UNKNOWN ### Response: (Severity: 3), (Category: FABRIC), (Description: --), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_SKYWARP_NETIO_LIB-4-GET_MYNODEID_FAIL ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Unable to determine my node id using platform api.), (Recommended Action: Please capture show proc ouput and show logging output - 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPV6-3-NOPACKET ### Response: (Severity: 3), (Category: IP), (Description: Most likely a resource problem within the system.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-5-ROUTE_UPDATE_FAIL ### Response: (Severity: 5), (Category: ROUTING), (Description: Was not able to commit at least one route after retrying for the maximum number of times. In this case, mfwd will restart in an attempt to recover. This is not an error. It just indicates that mfwd is restarting to recover from possible stale route problem.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-6-REPLY_ERR_SEND ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LMRIB_API-3-RPC_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An RPC-related error occurred in an RPC call from the LMRIB API. This indicates a problem in client table registration or unregistration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging | inc err command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging | inc err output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show lmrib client trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show lmrib client trace output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGV6_SERVICES-7-DEBUG ### Response: (Severity: 7), (Category: PLATFORM), (Description: This is a debug message in the CGV6 SERVICES PROCESS to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.), (Recommended Action: 'show logging' to confirm errors) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_0_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-7-WARM_RLD_OK ### Response: (Severity: 7), (Category: PLATFORM), (Description: Card seems warm reloaded successfully), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCONBKUP-7-INTERNAL_ERR ### Response: (Severity: 7), (Category: MGBL), (Description: Error encountered while Backing up the ASCII System Configuration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-3-TREE_UNLOCK_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failure occured while unlocking a mutex), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-6-STATUS_SET_INFO ### Response: (Severity: 6), (Category: OS), (Description: This is during the device Initialization. Failure to set the status file to indicate Qnet is not yet ready %s- qnet name %d- Error code %s- Error description), (Recommended Action: Informational) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKPLATFORM-3-CONNECTFAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The platform driver was not able to connect to the packet server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-LACP_PKT_DELAYED ### Response: (Severity: 5), (Category: L2), (Description: The received partner sequence number is too far behind the last sent actor sequence number. This indicates either that one or more LACPDUs sent to the partner device have been dropped, or there is a long delay on the partner device in processing the LACPDUs.), (Recommended Action: This message indicates one of two possibilities. Either LACPDUs sent by this device have been dropped before delivery on the partner, or the partner device is unable to process incoming LACPDUs in a timely fashion. Check packet counters on both devices for drops, and for rate limited LACPDUs on the partner device (using show lacp counters if it is an XR device). Check also for high CPU load on the partner device.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-CHDIR_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP_VRF-3-INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred while initializing the BGP VRF module. The BPM process will be restarted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_5_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-4-ERR_CHKPT ### Response: (Severity: 4), (Category: L2), (Description: MFR MA encountered an error using the Checkpoint Service. The error message describes what operation has failed and why it failed. The most likely reason for this a low memory condition but the error could also be caused by a programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ACL-6-IPACCESSLOGP ### Response: (Severity: 6), (Category: ACL), (Description: These messages are issued whenever access lists are configured with the 'log' option and matches with the IP protocol type TCP (or) UDP (or) SCTP. This message is seen for the first match and for each match after the hit count is greater than 0x7FFFFFFF(2147483647).), (Recommended Action: This is information only message, no action required No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-4-LFA_FRR_BKUP_INCOMPLETE ### Response: (Severity: 4), (Category: PLATFORM), (Description: A backup of the listed protected interface is found incomplete. This can cause potential traffic loss during FRR.), (Recommended Action: Make sure that the bkup interface is ARP complete before FRR.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_THOR_L2FIB_ATOM-3-LTRACE_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the ltrace module in the platform L2FIB ATOM component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-PARAMETER_WRONG_BLOB_TYPE ### Response: (Severity: 7), (Category: INSTALL), (Description: An invalid parameter has been unexpectedly passed to the Install infrastructure. This is a coding error. The current request or operation will not be completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-3-IO_COMM_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The software is not able to communicate with the power-module. This may have an impact on the router's available power budget, as the software cannot determine the power-module capacity in this state. This condition should be resolved prior adding additional FRU to the router.), (Recommended Action: This may be a transient condition, as the software will continue to try to establish communications with the power-module. If this condition does not clear on it's own, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAK-3-DEBUGINITFAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An error occurred during packet debug events initilization. Refer to the error message for the particular cause.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-INFO_RT ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef trace location <> show cef platform trace common all location <> show tech cef show version show install summary show cef platform services resource oor common loc show cef platform services resource shm-objects common loc show cef platform services trace common all reverse loc show cef platform services trace common errors reverse show cef platform services trace common all reverse loc Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-TX_OVF_ERR_FIA11 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA11 Tx overflow error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rewrite-4-INIT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: An error was encountered while the specified process was initializing. The error message contains details about the source of the error.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-6-ENFORCE_METERED_USAGE ### Response: (Severity: 6), (Category: LICENSE), (Description: Smart Licensing is enabled with post-paid billing method.), (Recommended Action: 'INFO') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-MRID_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-3-CBC_ALRM_PWR_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Power fault alarm indication received from CBC. This may be a serious failure and card will not come up. Try Hard OIR the card and check card is coming up or not. If still card is not booting then RMA is needed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-2-FAB0_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: LC CPU controller driver detected fabric parity from RP/RSP.), (Recommended Action: If all other LCs also report this parity error alongwith peer RP/RSP, then check for any bent pins on the RP/RSP for which the problem is reported. Reload the RP/RSP that has the problem. If problem persists, contact support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_MGT_CV_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-0 MGT code violation on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to setup event manager.), (Recommended Action: No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE* Or try restarting manually. Get the job id from 'show processes afmon_ea location <>' 'process restart location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB_ALARM-3-STORM_CONTROL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Storm control policer allocation has failed on at least one bridge port.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDLD-6-NO_NEIGHBORS ### Response: (Severity: 6), (Category: L2), (Description: The UDLD session on the interface has started or been reset, and has not found any neighbor devices. UDLD protection is not in place until communications with a peer device have been re-established.), (Recommended Action: Enable UDLD on the peer device to protect the link using UDLD.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDS_DB-3-MUTEX_UNLOCK ### Response: (Severity: 3), (Category: OS), (Description: Failed to unlock the mutex.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_9_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-MINMSGLENGTH ### Response: (Severity: 3), (Category: MGBL), (Description: 'The message length must be greater than minimum message length. The minimum message length varies by request code.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-MYADDR_DB_ERR ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-2-CRITICAL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Critical error during improper updation of variables or incorrect return state in MPLS FIB platform), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCM_SWITCH-5-UNKNOWN_CHASSIS ### Response: (Severity: 5), (Category: PLATFORM), (Description: Unrecognized chassis type hence it reboots.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBUS-3-HBM_PON_FLOW_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates a fault with the NP HBM memory. Displays the error associated with the power on operation.), (Recommended Action: The line card needs to be returned for repair.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-ASPATH_TOO_LONG ### Response: (Severity: 4), (Category: ROUTING), (Description: This message indicates that the UPDATE message contains AS_PATH or AS4_PATH attribute that is too long. Such long ASPATHs could be the result of an error on the neighbor and are not found in normal updates. The received UPDATE message is subject to 'treat-as-withdraw' behavior i.e. the associated NLRIs are withdrawn.), (Recommended Action: Check the UPDATE messages received from the neighbor.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-DEBUG_INIT_EVENT ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when initializing debug.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-GET_PROVIDERS_REPORT ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the infrastructure is behaving incorrectly. The Package infrastructure could not get a required providers report, so processing of the current operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLU-4-PROFILE_INACTIVE ### Response: (Severity: 4), (Category: PLATFORM), (Description: A memory resource profile has been configured for the system using '(admin-config)#hw-module profile <>'. However, this profile has not been activated on the line card that originated the warning message. Use '#show hw-module profile <> location X/Y/cpu0' to see what profiles are currently active on the line card.), (Recommended Action: Either the line card that originated the warning message must be reloaded in order to activate the configured memory resource profile on that card or the entire system must be reloaded. Consult the warning message for instructions.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_LIB-7-DEBUG_REGISTER ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when registering debug.), (Recommended Action: This is not a critical error and it can be ignored.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-4-EXTRANET_WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: A warning occurred in MRIB MVPN EXTRANET operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBCSVI_EA-3-NOT_FOUND ### Response: (Severity: 3), (Category: SERVICES), (Description: The SBCSVI EA process received a request to process an interface that does not exist in its database. This indicates some sort of internal inconsistency.), (Recommended Action: It may help to restart the SBCSVI EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERR_STR_RT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error information related to rate limitor in platform FIB), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-CPU_PKT_TOO_SHORT ### Response: (Severity: 2), (Category: PLATFORM), (Description: IBS from CPP packet too short error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-2-ERR_MUTEX_UNLOCK ### Response: (Severity: 2), (Category: FABRIC), (Description: The FIA driver cannot unlock the mutex after accessing the link, because of which it cannot configure the qlink ASIC on ASIC/channel errors or enabling the channels if the mutex is not working.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_12IN1-1-DCE_INVALID_CLOCKRATE ### Response: (Severity: 1), (Category: L2), (Description: The configured DCE transmit clock rate exceeds the range supported by the hardware for the installed cable type. This can not typically be validated at configuration time as the cable may not yet be installed or detected by the hardware. Max supported clock rates based on the cable type are: RS-530, RS-530A, RS-449, V.35: 8064000 bps X.21: 2016000 bps RS-232: 128000 bps The DCE clock rate will be reduced to the max rate supported by the hardware.), (Recommended Action: Reduce the configured clock rate to fall within the range supported by the hardware based on the installed cable type.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-UIDB_ALLOC_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: An attempt to create a interface failed as no PRM Uidb resource is free. Unable to allocate a Uidb index. Platform does not have any context for this interface and all future reference to the same would fail.), (Recommended Action: Avoid configuring additional interfaces. Or delete the unwanted interfaces to free up resources.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SEEK_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Most probably some problem with the procfs file system), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR backup tunnel preemption feature? ### Response: The MPLS TE FRR backup tunnel preemption feature allows a backup tunnel with a higher setup priority to preempt an existing backup tunnel with a lower hold priority. This ensures that higher priority backup tunnels can be established even if lower priority tunnels are consuming the backup resources. It provides a way to prioritize critical backup tunnels. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEMGBL-7-REGISTER_NOTIFY_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: An unexpected failure in register notification failed.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSI_MASTER-6-INFO_SVD ### Response: (Severity: 6), (Category: OS), (Description: There are restrictions to enable and disable Selective VRF Download. The text of the message displays more information.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_TOPAZ-7-ERR_HEARTBEAT_FAILURE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server heartbeat monitoring mechanism detected interruption in the periodic 'Hello' messages.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-MMAP_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath failed to map shared memory. This error could occur for two reasons. 1. The system is low on resources. 2. Error in the DPAA software.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect show log location output, show controllers dpaa trace all location output and show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-DBG_UNKNOWN_TRACEPOINT_NAME ### Response: (Severity: 6), (Category: ROUTING), (Description: An unknown tracepoint name requested for a debug filter.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP-6-INFO_DUPMAC ### Response: (Severity: 6), (Category: IP), (Description: ARP request received with the same destination MAC address as incoming interface MAC address.), (Recommended Action: Change the interface MAC address of one of the two devices.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-4-LOCK_FAILED ### Response: (Severity: 4), (Category: OS), (Description: An attempt to lock a mutex failed.), (Recommended Action: Please try restarting the process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_L2TP-6-DEBUG_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB L2TP component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-3-TYPE_UPDATE ### Response: (Severity: 3), (Category: MGBL), (Description: The process that is described by the node ID and job ID in this message sent a request for a stats type ID that cannot be handled. This will result in a failure to register for statistics collection.), (Recommended Action: Restarting the process described in this message will cause the request to be resent. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2C-4-WARN_EVENT ### Response: (Severity: 4), (Category: L2), (Description: The L2VPN Uberverifier has encountered a problem in its event loop and cannot continue. In this situation it should restart.), (Recommended Action: The L2VPN Uberverifier should recover on restart. If the problem persists, do the following: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKPLATFORM-6-REGION_TOO_BIG ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The platform driver attempted to define a packet memory region larger than is currently supported. This will be automatically reduced to a supported size.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_IPV6_EA-3-ERROR3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: SSE IP-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'l2vpn xconnect' command in IOS XR? ### Response: The 'l2vpn xconnect' command is used to configure a point-to-point Layer 2 VPN (L2VPN) service, also known as Virtual Private Wire Service (VPWS). It establishes a pseudowire between two provider edge (PE) routers to carry Layer 2 traffic. The 'xconnect' command binds an attachment circuit (such as an Ethernet interface) to the pseudowire. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-ORA_ORABUILD ### Response: (Severity: 3), (Category: ROUTING), (Description: There was an internal error in the routing policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-OBJINREPLACE ### Response: (Severity: 3), (Category: MGBL), (Description: 'The object type in the replace_type is invalid. The objtype is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-I2C_FAILURE_PM_PRESENCE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This I2C failure indicates that there was a fault when checking the presence information for the Power Modules in a power shelf. The shelf might have been removed or is not inserted correctly.), (Recommended Action: Try doing restarts of below process admin process restart envmon loc <>. admin process restart i2c_server loc <>. Location is from the node on which this ios_msg is seen. If the issue still persists collect required_info) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-SESSION_STOP ### Response: (Severity: 5), (Category: L2), (Description: After being secured, the MKA Session identified by the interface was ended or terminated. Possible reasons could be macsec config delete on the interface (or) no active pre-shared key present for the given CKN), (Recommended Action: If the MKA Session was not supposed to terminate, check the command history or other system logs, to find out the specific termination reason, `sh macsec mka trace errors ` and `sh macsec mka trace events` may help , diagnose the problem if the MKA Session was not supposed to terminate. Otherwise, no action required (normal operation)) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPP_TCAM_RM-3-MSG_SEND_FAILED ### Response: (Severity: 3), (Category: L2), (Description: Unable to send a message to the CPP TCAM RM server.), (Recommended Action: *SH_CMD show controllers pse qfp infrastructure tcam resource-manager usage location < > * *SH_CMD show controllers pse qfp infrastructure tcam resource-manager error parity location < > * *SH_CMD debug controllers pse qfp tcam resource-manager all job <> loc <>* If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_EVM_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: The FIA driver was unable to initialize an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LICENSE-6-ENFORCE_GRACE ### Response: (Severity: 6), (Category: LICENSE), (Description: The licensed feature is enabled for a grace period.), (Recommended Action: The customer should consider purchase the license.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HBAGENT-3-API_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: An infrastructure component has returned an error to the MBI infrastructure, so it may not be able to continue with the current operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is a Not-So-Stubby Area (NSSA) in OSPF? ### Response: A Not-So-Stubby Area (NSSA) is similar to a stub area in that it does not allow Type 5 external LSAs to be flooded into the area. However, unlike a stub area, an NSSA can import external routes into the area by using Type 7 LSAs. These Type 7 LSAs are converted into Type 5 LSAs by the ABR before being flooded into the rest of the OSPF domain. NSSAs are useful when you want to summarize Type 5 LSAs but still allow some external routes to be imported into the area. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLU-6-BKT_COMPACTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: A particular table had persistent memory failures due to heavily fragmented fragmented memory. As a last resort we attempted an aggressive memory recovery technique which succeeded. This is an informational message.), (Recommended Action: No action is required because the memory failures were auto-corrected. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_LSD-3-ERR_INVALID_THREAD ### Response: (Severity: 3), (Category: ROUTING), (Description: Detected single-threaded mpls-lsd code running on an unknown thread. This concurrency can result in corruption.), (Recommended Action: Collect LSD traces) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_3_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRLLIB-4-INT_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: The cpuctrllib ASIC Interrupt wrapper has detected that an ASIC driver has not cleared its interrupts at the source for 1000 consecutive times. This is possibly an error in the Driver ISR, that does not process and clear all possible interrupts, or malfunctioning HW. The Interrupt is disabled to prevent the ISR from hogging the CPU.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_BRIDGING-7-INVALID_MAC_CHUNK_TYPE_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Ignoring incoming chunk element has this is not expected type), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEATURE_AGENT-4-FILE_PARSE_ERROR ### Response: (Severity: 4), (Category: INFRA), (Description: A file containing feature data cannot be parsed. This is an internal software error, and as a consequence, feature capability information may not be available.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ncs4k-1-CRASH_NOT_SUPPORTED ### Response: (Severity: 1), (Category: PLATFORM), (Description: This is an error message in the fib_mgr to indicate that a process that doesn't support crashed has been restarted (crash, CLI or SMU installation) Process will trigger node reload to recover after collecting required information in the linecard's disk), (Recommended Action: Please collect the core file and fib_mgr traces from linecard's disk Ignore this if process was operationally crash like process crash command or process crash SMU installation those operations are not supported yet and nothing to debug at this point) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_LIB_COMMS-7-DEBUG ### Response: (Severity: 7), (Category: HA), (Description: Internal Debug Messages), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_TDM-7-OBJ_LEN ### Response: (Severity: 7), (Category: HA), (Description: An object save or get operation is being done with the wrong length buffer. This points to a logical bug in the client application.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PM-6-MEMORY_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Generic info messages pertaining to service PM.), (Recommended Action: No action is required for this message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: G709-6-INFO ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message in the G709 PI component to indicate an operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-4-FWC_FW_APP_RECV_FAILED ### Response: (Severity: 4), (Category: SECURITY), (Description: The Firewall Controller encountered an error while processing a message received from the Firewall Application, for example a corrupt message. As a result, some virtual firewalls may not operate correctly.), (Recommended Action: If some firewalls are not operating correctly after seeing this message, the system can be recovered by restarting the 'fwc' process using the 'process restart' command. If the error occurs repeatedly, contact your Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBDLLMGR-4-SYSCALL ### Response: (Severity: 4), (Category: OS), (Description: A system call failed. The calling function, the failed call, and error are displayed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRD-4-MISSING_TIMER_CONTEXT ### Response: (Severity: 4), (Category: SERVICES), (Description: Required data was not available when a timer expired. A role that should be applied now is unable to be applied.), (Recommended Action: Restart the service_role_daemon process to attempt to re-enable the role. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_RMA_CARD ### Response: (Severity: 3), (Category: FABRIC), (Description: The ASIC on the fabric board is faulty and being taken out of operation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-INSTALL_REG ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred when trying to register with the packaging subsystem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_PAIRING-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Event manager creation got failed.Software will automatically do recovery by restarting the drp_paring process.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM_XTC_WTX-3-GEN_ERR ### Response: (Severity: 3), (Category: IP), (Description: An error occurred in XTC WTX), (Recommended Action: This indicates a problem with WTX. Do the following action to check for errors. Copy the error message exactly as it appears on the console or in the system log. Issue the show mlib trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show mlib trace error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERR_INFO_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, INIT error information), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>), 'show install active', 'show logging console', 'show platform' and 'show version'. Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_CHOC3_DSX-1-SPA_RESET_NEEDED ### Response: (Severity: 1), (Category: L2), (Description: Due to framing change on SONET port, SPA need to be reloaded for spa to function properly.), (Recommended Action: Reload the SPA using CLI 'hw module subslot reload') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-ROUTER_ID_CONFLICT ### Response: (Severity: 5), (Category: ROUTING), (Description: This informational message appears as user-configured router-id is the same as IPARM's default router id. User should change the router-id.), (Recommended Action: User should change the router-id.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV_AGENT-6-IF_OIROUT ### Response: (Severity: 6), (Category: PLATFORM), (Description: SFP or XFP or CFP or QSFP enity is removed from the line card inv_agent removes the port data ehne), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_SDFEC_OOF ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPP-3-SYSDB_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: The system is unable to access Sysdb database.), (Recommended Action: Restarting the concerned process might solve the issue. If the issue recurs, issue the following command 'show tech-support sysdb' and 'show mgmt-plane trace client both' to gather data, and provide the exact error message and the gathered information to the Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-CIH_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: Registeration of the fia driver with the CIH library to process fia ASIC interrupts failed.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-2-CE_SWITCH_LINK_STATE_CHANGE ### Response: (Severity: 2), (Category: PLATFORM), (Description: The internal link interface for the specified port is down.), (Recommended Action: Gather the data listed in 'required_info'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP-4-PORTFAST_CHANGES_PENDING ### Response: (Severity: 4), (Category: L2), (Description: The MSTP specification dictates that Portfast state changes should only be made whilst a port is disabled. In order to enact the new portfast configuration, ports should be shutdown.), (Recommended Action: Shut and unshut any interfaces on which portfast configuration has been updated.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATS_INFRA-3-ERR_STR_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in stats infra component. The error string and return value gives the reason for the error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-COFO_ERR ### Response: (Severity: 4), (Category: ROUTING), (Description: Both link-id and ipv4 address not present to create a next-next-hop. advertise link-attributes config might be missing.), (Recommended Action: Config advertise link-attributes if not configured) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls label range' command in IOS XR? ### Response: The 'mpls label range' command is used to configure the range of local labels available for allocation by the MPLS protocols. It allows the operator to partition the label space and assign specific label ranges for different MPLS applications such as L3VPN, L2VPN, and MPLS TE. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_STAT_VEC_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-0 state error on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-REPO_INACCESSIBLE ### Response: (Severity: 3), (Category: INFRA), (Description: The IOS-XR install infrastructure has failed to access the specified repository. This may be due to the URL in the repository configuration not being accessible, or because the URL does not contain the required repository metadata.), (Recommended Action: Check that the specified repository has correct configuration, in particular that the URL is accessible and represents a repository.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-BD_ALREADY_ASSOCIATED ### Response: (Severity: 3), (Category: L2), (Description: Bridge domain is already associated with logical switch, first remove this association.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-3-BPDU_INCORRECT_DIRECTION ### Response: (Severity: 3), (Category: L2), (Description: STP only expects to be punted RX packets, but has received a BPDU with the TX direction.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_IPHC_CONFIG ### Response: (Severity: 4), (Category: L2), (Description: PPP MA received invalid or unsupported IPHC config for this interface. The error message describes which piece of config is invalid. The most likely reason for this is incorrect IPHC user configuration.), (Recommended Action: Check that the IPHC user configuration is valid and supported.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBSOC-4-FD_CLOSED ### Response: (Severity: 4), (Category: OS), (Description: MB socket FD closed), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Cisco IOS XR microkernel architecture? ### Response: The Cisco IOS XR microkernel architecture is designed to provide a highly modular, scalable, and resilient operating system. It keeps most OS functionality outside the kernel in separate processes with protected memory spaces. This enables fault containment, process restartability, and minimizes service disruption due to process or kernel failures. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_REPAIR_DATABASE ### Response: (Severity: 4), (Category: L2), (Description: When repairing the checkpoint structures for the named database an error occurred in the database checkpoint registration. As a result the process was intentionally restarted.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPL-3-PAK_CSUM_MISMATCH ### Response: (Severity: 3), (Category: OS), (Description: A checksum mismatch was detected for a packet by NCD.), (Recommended Action: The clients of NCD will attempt to recover from this situation by retransmitting the packets. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise, take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-APS_SF_SD_EVENT ### Response: (Severity: 3), (Category: OS), (Description: APS SF_SD Triggers from Alarm HAL. It is applicable for Digi 20x10g and 2x100g Digi cpak cards.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTS-3-TSS_CMD_FAIL ### Response: (Severity: 3), (Category: IP), (Description: A software error occurred while exeucting a TTS command.), (Recommended Action: The arguments supplied to tts commands are most probably wrong. Check the arguments. Or the sequence of operations could be wrong.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-6-INFO_USER_LOGOUT ### Response: (Severity: 6), (Category: SECURITY), (Description: SSH vty user logged out.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROL_DRIVER_RSP4-3-SSD_PWR_FAULT_ERR ### Response: (Severity: 3), (Category: DRIVER), (Description: This indicates that IOFPGA has detected the PWR fault for SSD, there is a potential risk to the SSD device that it may lead to indeterminate state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_DEBUG-3-CLEANUP_ERR ### Response: (Severity: 3), (Category: L2), (Description: Debug library cleanup failed), (Recommended Action: Please contact Cisco TAC for support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_RP-4-LTRACE_INIT ### Response: (Severity: 4), (Category: PLATFORM), (Description: Failed to initialize the ltrace module in the platform L2FIB (D)RP component.), (Recommended Action: Platform software will correct itself if this happens. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-6-INFO_REKEY ### Response: (Severity: 6), (Category: SECURITY), (Description: The sshd rekey information.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_LCP-6-LOCAL_MTU_TOO_SMALL ### Response: (Severity: 6), (Category: L2), (Description: The peer has sent a NAK in response to the local MRRU value. The value it is suggesting for the MRRU is larger than the local bundle admin MTU, so it cannot be accepted. However, suggesting a smaller value will almost certainly lead to repeated NAKs (since the peer should be suggesting its minimum possible MRRU value), so the LCP session will be closed for a short time and then negotiations will be retried.), (Recommended Action: Reconfigure the interface's MTU to a larger value, taking into account the Layer 2 headers. Once these headers have been subtracted, the Layer 3 MTU needs to be at least the value suggested in the message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-POLICER_VERIFY_FAIL ### Response: (Severity: 3), (Category: QOS), (Description: QoSEA while verifying finds the hardware is not updated properly after retry), (Recommended Action: Remove and reapply policy and check the hardware and sw entries are in sync.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cds_proxy-3-MUTEX_LOCK ### Response: (Severity: 3), (Category: OS), (Description: Failed to lock the mutex.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOGMIB-3-NOMEM ### Response: (Severity: 3), (Category: SNMP), (Description: No memory on the system to perform this opertion.), (Recommended Action: Collect the show logging output , along with show watchdog memory-state and also collect show memory and show process memory of mibd_infra on the location where the process have been seen) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS VPN carrier supporting carrier feature? ### Response: The MPLS VPN carrier supporting carrier (CSC) feature enables one MPLS VPN service provider to allow other service providers to use a segment of its backbone network. The service provider that provides the segment of the backbone network to the other provider is called the backbone carrier. The service provider that uses the segment of the backbone network is called the customer carrier. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of a BGP route-map on IOS? ### Response: A BGP route-map on IOS is used to filter and modify BGP path attributes for routes being sent to or received from a neighbor. It allows matching on prefix, AS path, community, etc. and setting attributes like MED, local preference, community, etc. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-DATAARRAYTYPE ### Response: (Severity: 7), (Category: MGBL), (Description: The datatypes entered in a data array do not match the the expected datatypes.), (Recommended Action: Use the classinfo command to get more information about the naming or value information of a class. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_TRAFFIC_ALERT-2-GRP_ALM_CRIT ### Response: (Severity: 2), (Category: SERVICES), (Description: The monitored flow has traffic issues as indicated by the react trigger. The problem is introduced either at some upstream router or even at the traffic source itself. Alternatively, a configuration mismatch between the traffic source and this router (for the flow data rates etc) can cause this error.), (Recommended Action: Check to see if traffic source is indeed sending traffic. Check that the traffic characteristics defined at the source match that on the monitoring router. Trace the traffic flow upstream to the source and verify flow-mon statistics at each applicable hop. Check for packet drops for the flow at intermediate hops - between source and the monitoring router) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-S2L_BFD_TIMEOUT ### Response: (Severity: 5), (Category: ROUTING), (Description: The BFD session for the specified interface destination timed out. \ The first %s refers to the tunnel name. The second %s refers to \ Sub-LSP destination. The third %s refers to list of RRO addresses. \), (Recommended Action: None. This is a solicited message (by 'logging events bfd-status' \ configuration under tunnel interface) and is informative only. \) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTP9 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_ETHER-2-LTRACE_RETRY_ERR ### Response: (Severity: 2), (Category: L2), (Description: Jacket process spawns the SPA process and waits for the initialization to complete. But initialization fails putting SPA into FAILED state. As part of retry mechansim, the above message is seen.), (Recommended Action: If the issue occurs, Check the SPA state. If it is not OK, then collect the following traces 1) show plim jacket all location 2) show hw-module traces infra detailed location 3) show plim ether trace info/error location 4) console logs) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_BAD_ID_LENGTH ### Response: (Severity: 4), (Category: ROUTING), (Description: Bad system ID length (ID-LENGTH, should be 0 or EXPECTED-LENGTH) from SOURCE_IF. This system received a pdu reporting an invalid system ID length of ID-LENGTH. This system only accepts values of 0 and 6 (both indicate 6). The packet has been ignored.), (Recommended Action: Identify the source of the offending packet and correct it. If the message recurs 'debug isis packet-errors detail' may be used to provide a dump of the problematic PDU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_LMI-2-INIT ### Response: (Severity: 2), (Category: L2), (Description: During Frame Relay Local Management Interface (fr_lmi) process startup an unrecoverable error occurred. The process fr_lmi will exit and should be restarted by the System Manager. The imapct overall would be LMI protocol not running and line protocol state messages will not be exchanged between the nodes.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-PKT_LEN_ERR_1_FIA_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet length error from FIA for NPU-1 on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-3-INVALID_ARGS ### Response: (Severity: 3), (Category: OS), (Description: Detected invalid arguments.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-SRGB_INFO ### Response: (Severity: 6), (Category: ROUTING), (Description: Information regarding allocation, free, or other SRGB events. IT should not be alarming), (Recommended Action: IF this message continues to be displayed for for several minutes, then restart the isis process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD-3-FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: FWD Driver partner encountered a fatal error and is not able to recover from the error.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed the there is no need to take any action. Otherwise check whether the error code contained in the message indicates that there was a failure to allocate the necessary memory and take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If resource allocation was not the problem and it hasn't been fixed by a subsequent restart then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-DEBUG_REGISTER_FAIL ### Response: (Severity: 3), (Category: HA), (Description: An internal error was detected when registering with the debug library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-AF_SLOW_PEER_RECOVERED ### Response: (Severity: 5), (Category: ROUTING), (Description: The peer previously declared as slow has caught up with its other peers.), (Recommended Action: The issue has been resolved no action is needed) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_DEBUG_INIT ### Response: (Severity: 3), (Category: OS), (Description: The program cannot initialize its debug capabilities.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-3-TIMER_INIT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The shelfmgr could not initialize one of its timers, this may occour when sufficient resources are not available. The shelfmgr will attempt to recover by restarting up to 5 times. If the issue persists, the RSP will be reset which will cause the standby RSP to take over as active.), (Recommended Action: None, since the system will perform recovery action automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-3-LIB_INT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform Fault Manager DLL encountered an error due to internal software issue and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP-4-WARN_INIT ### Response: (Severity: 4), (Category: IP), (Description: The ARP process failed to initialize correctly. In this situation ARP restarts, but ARP may not recover if there is a persistant error in the IOSXR system and ARP is later unable to reestablish its connections and initialize successfully.), (Recommended Action: Please collect the output of show tech-support arp. If the issue is seen repeatedly Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-TEMP_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Over temperature error), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VMANCLNT-5-VMAN_NOTICE ### Response: (Severity: 5), (Category: LIB), (Description: Notice messages from virtualization manager client library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDM_CFG-1-ERR_WARNING_RDM_CFG_MISMATCH_ALL ### Response: (Severity: 1), (Category: L2), (Description: The user configuration has caused an inconsistency in the interface hardware profile.), (Recommended Action: Please reload the router or all msc-x boards to remove the inconsistency. To reload use the command '(admin) reload location all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEAT_MGR-3-MSTATS_ALLOC_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Feature Manager failed to allocate statistics entry for ACL. Number of ACL entries requiring statistics entries has exceeded statistics entries reserved for security ACLs on this line card. As a result, per ACE hardware accouting for the failed ACL entries is not available. There is no impact on ability to apply security ACLs in hardware.), (Recommended Action: If per ACE hardware accouting is needed for ACL in error message, reduce security ACL configuration on this line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB-7-ERR_EVENT_CONN_EVM_HANDLER ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to register event handler for the posix message queue. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-6-MAX_AGENT_SESSIONS_EXCEEDED ### Response: (Severity: 6), (Category: L2), (Description: Each linecard is only able to host specific number of BFD sessions. This message indicates that maximum number of hosting BFD sessions has reached its maximum. Those session creating requests after reaching this limit will purposely be prevented from being created. These prevented sessions will continuously be retried to be created in the These prevented sessions will continuously be retried to be created in the background, and they will be once resources are available (ex: once some existing essions are deleted). Those sessions in the retry queue can be viewed via 'show bfd session pending' command.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-3-NBR_DOMAIN_CERT_EXPIRED ### Response: (Severity: 3), (Category: SERVICES), (Description: 'The domain certificate of the neighbor device ' 'has expired'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-TIMEOUT_ALMOST_EXPIRED ### Response: (Severity: 4), (Category: INSTALL), (Description: The timeout associated with an install message was close to expiring. This is a non-error condition.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the IP Service Level Agreement (IP SLA) feature in Cisco IOS XR? ### Response: IP Service Level Agreement (IP SLA) in Cisco IOS XR allows measuring network performance metrics such as latency, jitter, and packet loss. It helps in monitoring the quality of service (QoS) and service level agreements (SLAs). <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-ROUTES_REPLAY_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Serivce layer failed to replay routes to Routing Information Base.), (Recommended Action: The Forwarding Information Base may be inconsistent. Controller/agent may initiate a recovery action by unregistering impacted VRFs and replay a new Forwarding Information Base. This error may occur on process restarts if objects cannot be played back to Routing Information Base.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-4-CLIENT_WRITE ### Response: (Severity: 4), (Category: ROUTING), (Description: A client attempted to write an invalid update.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_CLI-3-SYSDB_GET ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP CLI Agent was unable to retrieve the specified item from the SysDB component.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-3-ADDIF_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM L2FIB, error), (Recommended Action: Ensure only one of the interfaces mentioned is added to the bridge domain.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-GST_PWM_TIMEOUT_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: GST PWM not received within 1 ms on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PINGMIB-7-DEBUG_REGISTER ### Response: (Severity: 7), (Category: SNMP), (Description: A software error occured when the ping process try to register for debug initialization. call failed.The process will attempt to recover from this situation by exit. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Retrying ping mib with time gap migh help.), (Recommended Action: The process will attempt to recover from this situation by exit. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Retrying ping mib with time gap migh help. If that does not work contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-3-DEV_SFP_SUPPORTED_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A supported error was detected during SFP initialization. A support error is reported when the SFP type can not be determined or it is not supported on the platform. The SFP is the pluggable optics on the line cards. SFP initialization may happen when linecard boots up, SFP OIR and line card process restart. The optics will not be enabled if an SFP supported error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the SFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRP_UPGRADE-3-SPAWN_CP ### Response: (Severity: 3), (Category: MGBL), (Description: Failed to spawn the 'cp' process Unable to start copying configuration from active RP to PRP.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LACP_LITE-3-ERR_SHMEM_TRNC_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Attempt to truncate the shared memory file fails), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-MAX_DISABLE_RETRY ### Response: (Severity: 3), (Category: ROUTING), (Description: Reached the maximum number of retries to disable multicast), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_COM_IFIB-3-CONFIG_MISSING_FLOW ### Response: (Severity: 3), (Category: OS), (Description: Error in IFIB flow handling configuration. The named flow type was not explicitly configured and will have default characteristics applied.), (Recommended Action: Provide the following log: Collect Console logs and following Information -From the Shell promt of LC and RP, fetch the file /pkg/etc/inflow.conf) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_EA-3-INIT ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of the Service Virtual Interface infrastructure. This resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-4-BOOTSTRAP_WARNING ### Response: (Severity: 4), (Category: INFRA), (Description: ZTP was not disabled by the user configurations.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVM-7-HEAP ### Response: (Severity: 7), (Category: OS), (Description: An Event Manager library function was not able to obtain HEAP memory space.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_MQ_OFLOW_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue overflow error on XAUI 1 MQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-CERR_REGISTER_DLL ### Response: (Severity: 7), (Category: INSTALL), (Description: The call to register the error messages of the Package infrastructure failed. Any errors returned from the Package infrastructure will not be decoded into user-friendly strings.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_PWR_SUPPLY_ALARM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBUS-6-INFO_MSG ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is a informational message in the SBUS Driver to indicate an operational status.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-4-ERR_ECM_CREATE ### Response: (Severity: 4), (Category: FABRIC), (Description: The Fabric driver was unable to create an event connection manager for EDM. Fabric driver and the System should continue to function as normal, with the exception that the 'show' commands for Fabric driver will not be available.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_5_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TIMER-3-TWTIMERALLOC ### Response: (Severity: 3), (Category: OS), (Description: Could get access to OS timer resources.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-4-TX_KEEPALIVE_SLIP ### Response: (Severity: 4), (Category: ROUTING), (Description: Heavy CPU load or process blockage resulted in slip of discovery transmission. This may result in session flap.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAM_MANAGER-3-NOTHING_READ ### Response: (Severity: 3), (Category: OS), (Description: Read file descriptor failed with specified message.), (Recommended Action: Check pam_manager process, show context, collect console message. Report this message to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSU-4-PM_OPERATION_MODE ### Response: (Severity: 4), (Category: LIBRARY), (Description: The power module output is enabled or disabled by testing tool.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_GENERAL ### Response: (Severity: 3), (Category: SECURITY), (Description: SSH encounterd some error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-3-RECORD_TOO_SHORT ### Response: (Severity: 3), (Category: OS), (Description: A feature record is too short.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_4_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias less than or equal to the low laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTSDRVR-6-OTS_PROV_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates success of provisioning), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-RESPONSE ### Response: (Severity: 4), (Category: SNMP), (Description: A response destined for the given address could not be sent. This could be due to a low memory condition. It also might be due to the fact that there is no SNMP transport process(udp) running for that transport protocol .), (Recommended Action: Check the running processes to ensure that an udp process is running. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR-4-LTRACE_INIT_FAIL ### Response: (Severity: 4), (Category: FABRIC), (Description: ltrace initialization failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-WARN_BAG_REG ### Response: (Severity: 4), (Category: SNMP), (Description: Failed to register the bags with SysDB. The access to SNMP statistics and MIB items in /oper/snmp/info through 'sysdbcon' might not be available. This is likely due to an internal software error.), (Recommended Action: Restart snmpd process.if still noticed this message check the state of snmpd process 'show process snmpd' and contact technical support representative. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_HEAP-7-TBL_OBJ_SEG_MISMATCH ### Response: (Severity: 7), (Category: HA), (Description: When the table ID and object ID are mapped to segment numbers, they do not match. Since an object belongs to a table and therefore resides in the same segment, this indicates a coding error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTU0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ERRDIS-4-DEBUG_CLEANUP_FAILED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The Verification Daemon failed to cleanup its debug registrations, this may leave stale state in the debug infrastructure. The process is exiting anyway, but subsequent process restarts may hit errors within the debug infrastructure during initialization.), (Recommended Action: This error message may be safely ignored unless subsequent process restarts fail. If subsequent restarts fail, gather the output of 'show tech-support sysdb' and contact your local support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_BDI_DEMA ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM-7-ERROR_BOARD_READ ### Response: (Severity: 7), (Category: MEDIA), (Description: can not read board type. - platform_get_hw_board_type_revision() return err), (Recommended Action: 'reload MSC, and if issue persists, RMA the MSC') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-4-CHKPT_SAVE_FAILURE ### Response: (Severity: 4), (Category: SECURITY), (Description: Encountered a checkpoint save failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-3-API_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: An infrastructure component has returned an error to the MBI infrastructure, so it may not be able to continue with the current operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APPMGR-3-INSTALL_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The IOS-XR appmgr has failed to install an rpm on the specified node.), (Recommended Action: Inspect the error information and retry the installation after addressing any issues.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-NON_SERVICES_PLIM_MISPLACED ### Response: (Severity: 4), (Category: PLATFORM), (Description: Non-Services PLIMs in the upper slot (s = 0..7) may only be powered on if there is no Services PLIMs powered on in the paired lower slot (s+8).), (Recommended Action: Place the NON-Services PLIM in a lower slot 8 - 16, or in the upper slot (s = 0..7) where there is no Services PLIM in the lower slot (s+8).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_BAD_CODE_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_BAD_CODE interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to troubleshoot MPLS L3VPN route leaking issues? ### Response: To troubleshoot MPLS L3VPN route leaking issues, verify import and export RT configurations and use 'show bgp vpnv4 unicast vrf MyVRF' command. show bgp vpnv4 unicast vrf MyVRF <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-5-SR_PATHS_LIMIT_CONFIG ### Response: (Severity: 5), (Category: OS), (Description: This message appears if the 'segment-routing traffic-eng oor max-paths' configuration is changed to a value that exceeds the total number of SR paths that are currently programmed.), (Recommended Action: You can shut down individual policies to reduce the number of SR paths that are programmed to meet the new limit.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS LDP downstream on demand feature? ### Response: The MPLS LDP downstream on demand feature is an LDP label advertisement mode in which a downstream router advertises a label to an upstream router only when it is needed to forward traffic. This is more scalable than unsolicited downstream mode. It is enabled with the mpls ldp downstream-on-demand command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How do you initiate a configuration rollback in IOS XR? ### Response: To initiate a configuration rollback in IOS XR, you can use the 'rollback configuration' command followed by the rollback point ID. The rollback point ID can be obtained using the 'show configuration rollback list' command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_16P_OC48-3-GENERIC_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A generic error is occurred in plim_16p_oc48 PLIM driver. Cause of the error will be mentioned in the message displayed. This message is for debugging purposes.), (Recommended Action: Please collect the output for the CLI mentioned in the required_info immediately before the ltrace buffer wraps.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-USAGE ### Response: (Severity: 7), (Category: SYSDB), (Description: Incorrect command line parameters were passed to the sysdb server, and so it failed to start.), (Recommended Action: Check the startup arguments passed to sysdb. A default configuration will be used if no parameters are passed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_11_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ORA-3-MISSING_BASE_TYPE ### Response: (Severity: 3), (Category: ROUTING), (Description: One of the operations in one of the ORAs used a base type that was not defined in any of the ORA math sets.), (Recommended Action: Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-L2VPN_SIGNAL_OVERLAP ### Response: (Severity: 4), (Category: ROUTING), (Description: BGP detected that the same prefixwas learnt with a signalling type different from what was learnt initially. We do not allow both types of signalling for nets with the same RD), (Recommended Action: This msg is info only. Need to check L2VPN Configuration in the topology across all PEs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-3-RMF_NOTIFY_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The dsc process could not notify RMF about the backup/primary dsc as mentioned in the message.), (Recommended Action: Restart dsc process If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to enable MP-BGP for MPLS L3VPN? ### Response: To enable MP-BGP for MPLS L3VPN, configure BGP with VPNv4 address family. router bgp 65000 address-family vpnv4 unicast neighbor 10.1.1.2 activate neighbor 10.1.1.2 send-community extended <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTH_SRV-3-ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Auth Service general error message with one prameter.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-UNDERCOUNTER ### Response: (Severity: 3), (Category: ROUTING), (Description: A counter with zero value was decremented.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-SYSMGR_SPAWN_SCRIPT_EBUSY ### Response: (Severity: 3), (Category: INSTALL), (Description: Timed out while trying to spawn a script via sysmgr), (Recommended Action: Please retry the operation after some time. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOMAIN_SERVICES-3-END_PROC ### Response: (Severity: 3), (Category: IP), (Description: The domain_services process was terminated unexpectedly. Please check if the error goes after doing process restart domain_services loc all.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected an QSFP+ temperature less than or equal to the low temperature warning threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TYPE6-6-FEATURE_STATE ### Response: (Severity: 6), (Category: SECURITY), (Description: Type6 srvice enabled/disbale on system based on configration of Masterkey and password6 encryption aes.), (Recommended Action: check both Masterkey and password6 encryption aes configured to enable the type6 service. for further detail contact the Cisco technical support representative with the gathered information and the exact error message as it appears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of OSPF areas? ### Response: OSPF allows a network to be divided into areas to provide hierarchical routing. Each area runs its own SPF calculation. Area border routers (ABRs) connect the areas to the backbone area. This reduces routing table sizes and the scope of LSA flooding for better scalability. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an IPv4 static route in IOS XR? ### Response: To configure a static route for IPv4 traffic, use the 'router static' command followed by the destination prefix and next-hop address. RP/0/RSP0/CPU0:router(config)#router static RP/0/RSP0/CPU0:router(config-static)#address-family ipv4 unicast RP/0/RSP0/CPU0:router(config-static-afi)#10.0.0.0/24 192.168.1.1 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-3-DB_SAVE_ERROR ### Response: (Severity: 3), (Category: LICENSE), (Description: The license manager encountered an error condition while saving the license database.This is a error while writing a file on disk . Licmgr will retrying writing the file to disk . Check the error string to determine what has happened.), (Recommended Action: Licmgr will retry writing the file to disk but if the problem persist please restart the licmgr process command 'admin process restart licmgr'. If the error log message is reoccuring, please collect informaiton using the commands 'show tech-support license ','show license trace platform' and contact your tech support representative and provide them the collected information and exact message as displayed on screen.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBDLLMGR-7-UNEXPECTED ### Response: (Severity: 7), (Category: OS), (Description: An unexpected condition encountered. This is not necessarily an error.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDPSNMP-4-AGENTIO_WARN ### Response: (Severity: 4), (Category: SNMP), (Description: SNMP-UDP process received a bad Message or failed to send a message to Agent. This may be due to a invalid message number or an internal software error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_SIM-7-NVRAM_SIZE_ZERO ### Response: (Severity: 7), (Category: MEDIA), (Description: Possible error during sizing nvram, the NVRAM may not exist), (Recommended Action: 'Check if formatted and present') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSU-4-PM_NOT_SUPPORTED ### Response: (Severity: 4), (Category: LIBRARY), (Description: The power module from Delta is not supported.), (Recommended Action: Replace the power module with BellPower PSU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install deactivate command in IOS XR? ### Response: The 'install deactivate' command is used to deactivate a previously activated software package. The package remains on the router's storage but is no longer active. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_ENS_MSG ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA driver ENS message communication error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPP-3-INTERFACE_MANAGER_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Management Plane Protection(MPP) tries to communicate with the Interface Manager Control Server(IMC), which is failed due to some unexpected error condition.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show mgmt-plane trace client both command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show mgmt-plane trace client both output, call your Cisco technical support representative and provide the representative with the gathered information. and *SH_CMD show running-config control-plane') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_LTRACE-6-ERR_INFO_VERBOSE ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the the platform L2FIB LTRACE component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-3-CON_TIMEOUT ### Response: (Severity: 3), (Category: IP), (Description: A telnet session from the specified peer has been timed out because no response was received from the remote end for the terminal-type query.), (Recommended Action: Please check the IP address of the peer. If it is not a trusted or known address, it could be a DoS attack. Please take steps to install appropriate ACLs or use MPP to avert the DoS attacks.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EM-7-FMS_QSM_REG_NOTIF ### Response: (Severity: 7), (Category: HA), (Description: An internal error was detected when registering for QSM notification.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-DBG_REGISTER_FAILED ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to register with the debug module for printing messages.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-WARM_BOOT_SKIPPED ### Response: (Severity: 4), (Category: PLATFORM), (Description: There is some unsupported configuration in use, which is not supported by warm-boot. System shall continue in cold boot mode. ASIC shall be reset and traffic forwarding would be impacted.), (Recommended Action: No further recovery is needed at this point. System shall auto-recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-3-IMC_BIND ### Response: (Severity: 3), (Category: IP), (Description: An error occured while trying to bind to IM server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_MAP-3-SOCKET_FAILURE ### Response: (Severity: 3), (Category: ROUTING), (Description: A socket error occurred in the map agent packet handling.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp mapping-agent trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp mapping-agent trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging process autorp_map_agent error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging process autorp_map_agent error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COREHELPER-3-INOTIFY_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Function specified in message failed with the specified error.), (Recommended Action: Check dumper process, show context, collect console message. Report this message to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-6-SESSION_DAMPENING_ON ### Response: (Severity: 6), (Category: L2), (Description: Exponential backoff dampening for BFD session has been enabled.), (Recommended Action: Session entered dampening state and remains dampened for backoff time. Either clear dampening or wait for backoff time for the session to come UP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-6-SET_DWDM_CARRIER_FREQ ### Response: (Severity: 6), (Category: L2), (Description: Optics Controller has provisioned optics to Non ITU Channel frequency inTHz.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-5-CONFIGURATION_SYNC_WARNING ### Response: (Severity: 5), (Category: INFRA), (Description: XLNCd is responsible for keeping the networking stacks for IOS-XR and Linux synchronized. By default it mirrors IOS-XR interface configuration into Linux, or it can be configured to selectively mirror Linux interface configuration into IOS-XR. This message indicates that a problem was encountered when attempting to perform this mirroring. Further details of the exact problem encountered can be found by running 'show linux networking status'. This problem may be a transient issue that can be resolved automatically. An example of such a transient issue is when a large configuration update coincides with a mirroring direction change.), (Recommended Action: Check 'show linux networking status' to determine exactly what problem was encountered. If the problem is that the configuration is unsupported in the destination system then consider adjusting the configuration in the source system. If a transient issue has occurred and nothing is reported by 'show linux networking status', then no action is needed and the issue has been resolved automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTAGENT-1-NOT_INITIALIZED ### Response: (Severity: 1), (Category: INFRA), (Description: The install software component could not build the software profile as the images with which the host, sysadmin and xr partitions are baked are not found.), (Recommended Action: Internal pxe logs have to be collected from the host partition of the failed node from /var/log. Once all the logs have been collected, the node can be recovered by one more internal pxe.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-UPGRADE_LICENSE_EXPIRE_CLOCK_CHANGE ### Response: (Severity: 2), (Category: LICENSE), (Description: Upgrade Grace period will expire if clock is set back in time for more than 24 hours.), (Recommended Action: Register the device to Cisco CSSM Server and rectify upgrade OOC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HBAGENT-2-FATAL ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message indicates that HBA agent encountered Fatal internal error. Embedded String will provide details of error encountered.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDS_DB-3-CLINFO_UNHOLD ### Response: (Severity: 3), (Category: OS), (Description: Failed to unhold the client.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-6-URG_CTX ### Response: (Severity: 6), (Category: FABRIC), (Description: Fabricq encountered a PCL Urgent Context error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-SEM_CORR_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Egress MUX detected SEM correctable error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-4-ERR_SOCKET ### Response: (Severity: 4), (Category: ROUTING), (Description: EIGRP was unable to set the specified socket option on the specified interface or VRF. EIGRP will not be able to receive any of the packets.), (Recommended Action: If the message persists, remove and readd the affected interface or VRF and if the problem still persists, restart EIGRP process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-3-ERR_SYSDB ### Response: (Severity: 3), (Category: IP), (Description: The Telnet Server has encountered an error using the SysDB Library.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-2-IMP_FAILED ### Response: (Severity: 2), (Category: SERVICES), (Description: Some aspect of diversion implementation has failed. This means that traffic may be inconsistently diverted for the specified interface (ie traffic may be diverted to the service card in the ingress direction, but not on egress). Note that, where the error message indicates a single interface that is affected, there may also be other attachments impacted by the error.), (Recommended Action: Restarting the rspp_ma process on the node which produced the error may solve the issue. If not, contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-6-ASYNC_XIPC ### Response: (Severity: 6), (Category: IP), (Description: The socket library has taken corrective measures or noticed a non-critical issue with the XIPC queue operations.), (Recommended Action: This is an informational message and no action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYNCFS2-3-FAILURE ### Response: (Severity: 3), (Category: MEDIA), (Description: Syncfs failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_4_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_4 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_STATE ### Response: (Severity: 4), (Category: L2), (Description: An error has occured processing an incoming SSRP state for the client.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.. Consider restarting the PPP MA process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key characteristics of the QNX Neutrino RTOS used in IOS XR? ### Response: QNX Neutrino is the third-party real-time OS used as the foundation for IOS XR. Its key characteristics are\n- Microkernel architecture\n- Preemptive multitasking and multithreading\n- Memory protection and fast context switching\n- Message passing based IPC\n- POSIX compliance\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-6-WRITE_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Display dst mac address. %s- Message description.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-6-PORT_STATE_CHANGE_LINK_UP ### Response: (Severity: 6), (Category: INFRA), (Description: Informational message indicating that the physical link state of the specified port has changed to up.), (Recommended Action: This is an informational message and does not necessarily indicate a problem. The port's physical connection should be checked if an unexpected status change occurs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVEDGE_DATA-3-IRL_MAXSLOT_LIMIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Recommendation for better IRL resiliency), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_BRIDGING-7-BRIDGE_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to delete bridge in the platform L2FIB BRIDGING component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-6-SESSION_BUNDLE_NO_ECHO ### Response: (Severity: 6), (Category: L2), (Description: This BFD over bundle session cannot run echo mode due to lack of PPS resources. The session will continue to run in async mode until PPS is available. Once PPS resources have been cleared up, then disable and enable echo mode on this interface via configuration to startup up the echo mode.), (Recommended Action: Remove other BFD sessions to free resources for this session) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB_API-3-ASYNC_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: 'An unhandled asynchromous error occurred in the MRIB API'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information as given in the required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_FAN_MISSING ### Response: (Severity: 2), (Category: PLATFORM), (Description: The CPT 50 Panel Fan Unit is Missing (SAT_FAN_MISSING) alarm is raised when the fan-tray assembly is not present in the CPT 50 panel.), (Recommended Action: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PREF_COMPR_LIB-6-V6_ANCHOR_PREFIX ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The IPv6 compression anchor prefixes are changed. The linecard needs to be reloaed to make the changes effective. This is not an error message or condition.), (Recommended Action: The IPv6 compression anchor prefixes are changed. The linecard needs to be reloaed to make the changes effective. This is not an error message or condition.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_SSE-3-ERR_INTERNAL ### Response: (Severity: 3), (Category: L2), (Description: An internal error occurred that was expected to succeed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-OOR_ROUTES_OK ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_HEAP-7-TBL_OBJ_SEG_MISMATCH ### Response: (Severity: 7), (Category: HA), (Description: When the table ID and object ID are mapped to segment numbers, they do not match. Since an object belongs to a table and therefore resides in the same segment, this indicates a coding error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_HFR_NETIO_LIB-4-GET_MYNODEID_FAIL ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Unable to determine my node id using platform api.), (Recommended Action: Please capture show proc ouput and show logging output - 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-3-PM_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB server failed PM initialization with above reson.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_LOCSW-6-LTRACE_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the ltrace module in the platform L2FIB LOCSW component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-4-DEVICE_NOT_IN_WHITELIST ### Response: (Severity: 4), (Category: SERVICES), (Description: 'The autonomic network registration authority ' 'will not allow this device to join as it is not in whitelist'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-6-REMOTE_SESSION_STOPPED ### Response: (Severity: 6), (Category: L2), (Description: A remote latching loopback session has been stopped. This is for informational purposes only.), (Recommended Action: If the session stop was unexpected, an attempt to restart the session can be made using the remote loopback start action command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_HEAP-7-DATA_CORRUPTION ### Response: (Severity: 7), (Category: HA), (Description: Data corruption is detected in checkpointing data structures. This will generally result in a single process failure.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_REBIND ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. This could be because the path supplied is invalid. The details are in the error string.), (Recommended Action: Check that the path is valid. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-3-ALARM_INDICATION ### Response: (Severity: 3), (Category: PLATFORM), (Description: Alarm indication received from CBC. This may be a serious failure (example: power sequencer failure), however process may continue functioning as expected (or successfully retry) despite the failure.), (Recommended Action: Provide the following CLI: (admin)# show env Use the pid from canb-server output to look for matching pid in the pfm output. If the alarm indication does not clear within 30 minutes, contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-UBLAZE_PRE_BOOT_FAIL ### Response: (Severity: 3), (Category: DRIVER), (Description: The MicroBlaze in IOFPGA has detected a fatal condition that is preventing the card from booting. The IOFPGA driver will attempt to recover from this failure by issuing a IOFPGA COLD RESET operation.), (Recommended Action: Physical remove and then re-insert the card to see if the problem can be corrected if the auto recovery mechanism performed by the IOFPGA driver cannot recover the failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-6-MASS_WITHDRAW_RECEIVED ### Response: (Severity: 6), (Category: L2), (Description: EVPN: Received mass withdraw indicator.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-GROUP_COUNT ### Response: (Severity: 3), (Category: OS), (Description: Unable to get group count for PLACEMENT_GSP_GROUP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support gsp command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support gsp output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-INCORRECT_GROUP_ID ### Response: (Severity: 3), (Category: OS), (Description: --), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are some special considerations when using TURBOBOOT on Cisco 12000 series routers? ### Response: When using TURBOBOOT on Cisco 12000 series routers (running IOS XR), note that\n- The ROMMON variable ENABLE_TURBOBOOT must be set to 1\n- The ROMMON variable TURBOBOOT must specify the disk slot (disk0 or disk1)\n- A minimum boot image (MBI) is required to boot the standby RP\n- The `show platform` command can be used to verify the standby RP has booted the MBI\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_5_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power greater than or equal to the high Tx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-CANNOT_GET_BLOB_SIZE_IN_A2STRUCT ### Response: (Severity: 7), (Category: INSTALL), (Description: An invalid parameter has been unexpectedly passed to the Install infrastructure. This is a coding error. The current request or operation will not be completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-5-DEVICE_UNFORMATTED ### Response: (Severity: 5), (Category: MEDIA), (Description: The media storage card specified is unformatted. There are problems with the boot sector contents.), (Recommended Action: Verify that media device was formatted. If not, then format media device manually. If it still fails, replace media device.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-CARD_RELOAD_CFG_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Setting of the reload attribute on the indicated card has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_10_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-INVENTORY_DESCRIPTION_NULL ### Response: (Severity: 3), (Category: MGBL), (Description: Description string is null.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-6-ENTITLEMENT_RENEW_SUCCESS ### Response: (Severity: 6), (Category: LICENSE), (Description: Authorization renewal request is successful.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMGR-3-ARTIFACTS_COPY_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Artifacts copy failed description), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ETHER-3-INCONSISTENT_CONFIG ### Response: (Severity: 3), (Category: L2), (Description: The user is trying to configure a dot1q vlan or qinq vlan that shares the same outer vlan id with that of an already configured qinq or dot1q outer vlan id. An error has to be reported to inform the user to remove the inconsisent configuration. The inconsistent configuration is that the same outer vlan id has been configured, and the software can only accept one sub-interface, so the last configured sub-interface is not applied.), (Recommended Action: Upon seeing this message, delete the sub-interface that has just been created. Otherwise the system will be in an inconsistent state, where the configuration believes it has two sub-interfaces sharing the same outer vlan id, when in reality the last configured sub-interface has not been applied. Traffic going to that shared outer vlan id will behave as the original configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Open Shortest Path First (OSPF) routing protocol? ### Response: OSPF is a link-state routing protocol used to distribute IP routing information throughout a single autonomous system (AS). It gathers link state information from available routers and constructs a topology map of the network. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP-6-INFO_MAC ### Response: (Severity: 6), (Category: IP), (Description: The specified MAC address is invalid as it is a broadcast address - all the bits are set. Configuration has therefore been rejected.), (Recommended Action: Configure the MAC address so that it does not have all the bits set.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-EVM_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath failed to create an an event manager. An event manager is a mechanism used to handle events. This error could occur for two reasons. 1. The system is low on resources. 2. Error in the DPAA software.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect show log location output, show controllers dpaa trace all location output and show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NF_PRODUCER-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to setup event manager.), (Recommended Action: No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-EVPN_MEM_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: Calloc operation failed, check memory usage for process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFEA_IPV4_EA-3-ERROR2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: AFEA IPV4-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-7-CHKPT_TBL_ADD ### Response: (Severity: 7), (Category: SERVICES), (Description: Failed to save a record into the given checkpointing table.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ONLINE_DIAG-3-PUNT_FABRIC_DATA_PATH_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: PuntFabricDataPath test failure detected, detail in the form of slot, NP, VQI'S. which that specific vqi is stuck and any subsequent data traffic pertained to that vqi's will be dropped.), (Recommended Action: 'please collect show tech fabric and contact Cisco TAC Support') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-OPERATION_LOCK_RELEASED ### Response: (Severity: 6), (Category: INFRA), (Description: Install operation lock which is maintained by the Admin install has been released. User is notified that a new install operation can be started.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE1_LANE_CRC_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE1_LANE_CRC_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBSOC-6-SVC_INFO ### Response: (Severity: 6), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_8_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROL_DRIVER_RSP4-3-RECOVER_PEER_RP ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-DEBUG_REGISTER ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when registering debug.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCCLASS-3-TREE ### Response: (Severity: 3), (Category: MGBL), (Description: A failure occurred while accessing the ATM VCCLASS internal data structrure. There might be an inconsistency between the SysDB and the vcclass tree or the vcclass tree is corrupted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_MQ_OFLOW_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue overflow error on XAUI 0 MQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK_LIB-3-SYSDB ### Response: (Severity: 3), (Category: OS), (Description: A call to a sysdb interface failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-RX_MAX_LEN_ERR_FIA11 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet maximum length error FIA 11 interface.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-SHUTDOWN_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: TACACS+ process failed to shutdown properly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-PFXLIMIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Number of prefixes for eigrp has reached the configured or default limit.), (Recommended Action: Use \'show eigrp accounting\' for details on the source of the prefixes and take corrective measures.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-TSPI_ASYNC_FIFO_L72_MBE ### Response: (Severity: 1), (Category: PLATFORM), (Description: TxSPI async FIFO low 72bits data multiple bits ECC error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-3-ETHERNET_DEVICE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ethernet driver failure. %s- Message description. %d- Reason for the failure.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRP-3-ERR_LIB_REG ### Response: (Severity: 3), (Category: L2), (Description: This message indicates this process has encountered an internal software error. Process was failed to register library routine. The process will automatically respawn up to a fixed number of times to try and recover.), (Recommended Action: Check if the linecard reported any other errors during the boot process as this error is normally associated with larger system issues. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-7-UNKNOWN_REQTYPE ### Response: (Severity: 7), (Category: OS), (Description: PlaceD received an unknown message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-2-GOLDEN_BIOS_BOOTED ### Response: (Severity: 2), (Category: FABRIC), (Description: Fabric Links will be down if system booted with Golden BIOS.), (Recommended Action: Check if Card is booted with Golden BIOS. In this case, it is expected Fabric will not come up on this Card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_CREATE ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. This could be because the item to create already exists. The details are in the error string.), (Recommended Action: Check that the item to create does not exist. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_0_SCH_MEMP_ERR_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Scheduler Hang, Sram or egress mid-fifo parity error on NPU-0 interface on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-4-FAILED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_RIB-3-ERR_PATH_ADD ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered in the call to ipv6_rib_batch_add_path.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-6-SAT_UNQUAL_PPM ### Response: (Severity: 6), (Category: PLATFORM), (Description: The Unqualified PPM Inserted condition occurs when a PPM with a nonqualified product ID is plugged into the card's port; that is, the PPM passes the security code check as a Cisco PPM but is not qualified for use on the particular card.), (Recommended Action: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-EBS_OC_DELM_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: EBS from FIA delm error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMC-3-RESTART ### Response: (Severity: 3), (Category: SYSDB), (Description: Conflict in LBL values.Need to restart.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-2-PHASE2_FATAL ### Response: (Severity: 2), (Category: MGBL), (Description: The TTY Server has failed to complete phase 2 initialization. For this instance of the server the failure is fatal; without the services that were being initialized the code will not be able to function.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTAGENT-4-XR_PART_PREP_REQ ### Response: (Severity: 4), (Category: INFRA), (Description: SDR Mgr has requested for SDR partition. Install will look for available partitions and if any partition has matching software then it will be provided else new one is created and baked with image/RPMs. User has to wait till SDR/XR is spawned. Reloading of card has to be avoided till SDR comes up.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPIDB-4-WARN ### Response: (Severity: 4), (Category: PLATFORM), (Description: A run time warning occurred during the pidb operation on the linecard. The reason for the error is dispalyed. Please call Cisco Support with the error information), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the configuration session lock feature in IOS XR? ### Response: The configuration session lock feature in IOS XR allows an administrator to lock the configuration mode so that no other user can make configuration changes. This prevents multiple users from making conflicting changes simultaneously. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ-3-ERR_INCOMPATIBLE_API ### Response: (Severity: 3), (Category: L2), (Description: Obsolete API usage, it can be caused due to incompatible component installed in the system.), (Recommended Action: No action is required. The process will automatically retry. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-IMP_SERVER_FAIL ### Response: (Severity: 3), (Category: L2), (Description: failed to initialize with IMP server), (Recommended Action: No action is required. Process will be restarted.If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to verify MPLS L3VPN configuration? ### Response: To verify MPLS L3VPN configuration, use the 'show vrf' and 'show bgp vpnv4 unicast all' commands. show vrf MyVRF show bgp vpnv4 unicast all <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-6-TRANSCEIVER_OIRIN ### Response: (Severity: 6), (Category: PLATFORM), (Description: TRANSCEIVER entity is inserted into the line card), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-7-ERR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failure in Inventory Manager resulting in error condition %s - indicates the reason of the failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-1-NODE_RELOAD_FAILED ### Response: (Severity: 1), (Category: INFRA), (Description: The IOS-XR install infrastructure has attempted, but failed, to reload one or more nodes in the system. These reloads are required to ensure that: - The appropriate software is running on each node - The set of running software across the whole system is consistent), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. It may be possible to issue a manual reload of the relevant node(s) from the XR CLI on the active RP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-CHKPT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POS-6-SOFT_BANDWIDTH_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: The soft bandwidth is changed according to the Max bandwidth of this port.), (Recommended Action: If any soft bandwidth is configured greater than current max badnwidth. That particular config has to be removed. Otherwise it will result in config failure on spa/LC reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VASI_MA-3-INIT ### Response: (Severity: 3), (Category: SERVICES), (Description: The VASI Manager failed to startup correctly. Though it will get automatically restarted, the error is unlikely to be recoverable.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE-7-MMAP_ERROR ### Response: (Severity: 7), (Category: OS), (Description: mmap system call returned an unexpected error Debug trace buffer initialization failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_MPLS_EA-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in MPLS EA. Typically, this is an error where the software fails to initialize or programming of forwarding feature fails. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef mpls trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-ERR_GENERAL ### Response: (Severity: 3), (Category: ROUTING), (Description: A non-fatal fault occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SE_P2MP_SRVR-2-ERR_EVM_EVENT_BLOCK ### Response: (Severity: 2), (Category: PLATFORM), (Description: An error occurred in the event loop. It may be possible to rectify it by restarting the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_GIFT-4-MBR_RETRY_NOTICE ### Response: (Severity: 4), (Category: PLATFORM), (Description: The hardware configuration for some bundle interfaces have not been applied; the system is retrying to apply the configuration. Hitting this error typically indicates that traffic on the bundle interface will be affected until the hardware configuration has completed.), (Recommended Action: None, platform software will correct itself if this happens. Verify the PD programming using how gift db retry location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSU-3-PM_NOT_INSERTED_PROPERLY ### Response: (Severity: 3), (Category: LIBRARY), (Description: The power module might not be fully inserted.), (Recommended Action: Please check the PSU and make sure the PSU is fully inserted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_PERSIST_HARD_RESET ### Response: (Severity: 1), (Category: PLATFORM), (Description: An ASIC error has occured and need a hard reset.), (Recommended Action: An error has happen and HARD reset has been performed to recover. Collect required information and contact TAC *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWRMON-1-ZERO_CAPACITY ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Capacity in the IDPROM is zero.'), (Recommended Action: Try restarting the using CLI command in exec mode - process restart pwr_mgmt If the error exists try -insert and re-insert the PM If the error exists - Replace the power module) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_UTIL-3-ASSERT_MSG ### Response: (Severity: 3), (Category: HA), (Description: Cdm hit an internal assert.Some api call didnot work as expected. assert will generate core dump.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the max-lsp-lifetime command in IS-IS? ### Response: The max-lsp-lifetime command is used to configure the maximum lifetime that an LSP can have. By default, the maximum LSP lifetime is 65535 seconds. If an LSP's lifetime exceeds this value, it is purged from the database. This command provides an upper bound on the LSP lifetime to prevent stale LSPs from persisting in the network. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_HFR-7-ERR_RRW_UNLOCK ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server failed to release rrw lock to the request record area in shared memory. This is a fatal error, the process will automatically restart.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_MGR-3-ADJ_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The SVII Adjacency Manager encountered an error while programming an adjacency. Packets may not be forwarded to the affected service interface. The name of the interface can be retrieved with 'show im chains ifhandle 0xabc', where '0xabc' is the interface handle shown in the message.), (Recommended Action: This error should only arise due to resource constraints (eg memory). Determine which resources are short, and make more available; then restart the 'svi_adj_mgr' process on the affected node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_SPP-3-ERR_THREAD ### Response: (Severity: 3), (Category: PLATFORM), (Description: HFR SPP Thread Error message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_CONF_PRX-3-ERR_ERRNO ### Response: (Severity: 3), (Category: SECURITY), (Description: Error , Error description.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_CLIENT-1-UPGRADE_SKIPPED ### Response: (Severity: 1), (Category: PLATFORM), (Description: The given FPD upgrade was skipped for the given reason.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-INIT_GR_EXIT_TOUT ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-6-FRR_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message provides information about the IP FRR events happening in the software at the location where the error is seen. This is not an error message. Typically, following events are logged in this message type. - End of successfull initialization of the software. - Start and end of a processing of new object that needs to programmed to the hardware.), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP_VRF-3-DUPLICATE_ID ### Response: (Severity: 3), (Category: ROUTING), (Description: A ID has been received from RSI that duplicates an existing VRF or table ID. As a result, the new ID has been ignored, and subsequent operation for that VRF will be incorrect.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-2-INIT ### Response: (Severity: 2), (Category: ROUTING), (Description: FIB initialization has failed due to the reason indicated in the message. The process will attempt to recovery by restarting. If the restart count is excessive then the node may reload. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-CPU_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: Card manager has detected that the CPU complex in the indicated card is reporting an error condition that could be fatal and would need user intervention to reload the card if it doesn't get auto-corrected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-IMG_DLOAD_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in downloading Linux/Application image. Cause of the error will be mentioned in the message displayed. This error prevents Services PLIM from coming up to its full functional Active state.), (Recommended Action: Do cold reboot of Services PLIM MSC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_2_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Rx power less than or equal to the low Rx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Rx power threshold values are read from the QSFP+.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure BGP community attributes for MPLS L3VPN? ### Response: To configure BGP community attributes for MPLS L3VPN, use the 'set community' command in route-policy configuration mode. route-policy MyPolicy set community 65000:999 additive router bgp 65000 address-family vpnv4 unicast vrf MyVRF neighbor 10.1.1.2 route-policy MyPolicy in <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-ERR_MEM_ALLOC ### Response: (Severity: 7), (Category: MGBL), (Description: XML schema browser was unable to allocate enough memory required to process the command), (Recommended Action: Memory on the box must be running low - are there services that can be stopped, or can more memory be added.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_VPLS-3-MAC_CFG_PW_CONFIG_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: mac limit/action on pw not supported.), (Recommended Action: Remove mac limit/action config from pw bport.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-CONFIG_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: config will be activated only after a line card reset), (Recommended Action: config will be activated only after a line card reset. Reboot the LC during the next maintenance window.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-CARD_IDPROM_READ ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC driver was not able to retrieve a valid IDPROM image from the indicated card. This failure will prevent registration of detail card information to the system inventory. The card will show up with UNKNOWN card type in show platform command output and it won't be fully operational due to this failure.), (Recommended Action: Use hw-module location location reload command to reset the card to see if it can clear any I2C issue that was preventing the reading of the IDPROM. If the problem is due to CCC FPGA not ready as indicated in the error message, then there is some HW issue that is preventing CCC FPGA from booting. If hw-module location location reload command cannot reset the card, try to physically OIR remove and then insert the card to see if CCC FPGA will boot. The status LED should turn on to solid yellow color when CCC FPGA boots.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the Configuration File System (CFS) in IOS XR? ### Response: The Configuration File System (CFS) in IOS XR is a virtual file system that stores the running configuration, committed configurations, rollback points, and configuration templates. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-FAILED_CREATE_THREAD ### Response: (Severity: 3), (Category: MGBL), (Description: config process is failing to create a separate thread for creating and handling edm requests.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_FPGA-2-EIO_TRAIN ### Response: (Severity: 2), (Category: L2), (Description: EIO training errors. The EIO link to the PLASPA failed to train. This will result in traffic loss through this PLIM.), (Recommended Action: Check seating of both the PLIM and the MSC and then reload the MSC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-USAGE ### Response: (Severity: 3), (Category: OS), (Description: Incorrect command line arguments were given to the module), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-GET_PROC_CURTHREAD_FAILED ### Response: (Severity: 6), (Category: OS), (Description: Dumper collects all the process related data by using system call devctl. If a devctl fails, then the core file will be incomplete. This will not impact the system.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-3-HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected an SFP temperature greater than or equal to the high temperature warning threshold. The SFP is the pluggable optics on the line cards. The temperature threshold values are read from the SFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd 'location all', 'admin show inventory' and 'show environment temperatures'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-FAILED_OUTPUT_ERROR ### Response: (Severity: 4), (Category: INSTALL), (Description: A user error occurred but failed to be output to the user.), (Recommended Action: Repeat the operation. Consult the release-notes if applicable.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-INVAL_ST_DRVR_HNDL ### Response: (Severity: 3), (Category: FABRIC), (Description: Error occured during fabric driver handler.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-1-I2C_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-ERR_FILE_WRITE ### Response: (Severity: 3), (Category: SECURITY), (Description: Error encountered while writing to the file .), (Recommended Action: Collect the output of show logging and inform Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-SHUTDOWN_CHECK_FAILED ### Response: (Severity: 4), (Category: L2), (Description: A Precision Time Protocol process could not determine whether all Precision Time Protocol configuration has been removed and so cannot exit safetly. Precision Time Protocol processes may be running despite no Precision Time Protocol configuration existing.), (Recommended Action: No action is required. If the message continues to be seen, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOMAIN_SERVICES-3-CREATE_TIMER ### Response: (Severity: 3), (Category: IP), (Description: The domain_services process failed to create and initialize its various managed timers.This message would appear during Initialization of DNS process (i.e. domain_services). The error should go away with process restart), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TIMER-3-NO_CHILD ### Response: (Severity: 3), (Category: OS), (Description: All parents in a managed timer tree should have at least one child.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-3-LWM_CHANNEL_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The rpl multi-version coordinator was unable to publish its channel in the global space. The coordinator will exit so the system manager can restart it. Route policy may not be operational until this is resolved.), (Recommended Action: This error message may be transient. Restart policy_repository and try the use case again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-1-FABRIC_ADMIN_CFG ### Response: (Severity: 1), (Category: FABRIC), (Description: If the admin startup config is not received, then the fabric planes cannot be configured and brought up. If the fabric is not UP, system cannot be used for any data traffic.), (Recommended Action: This indicates a problem in config manager or sysdb in the system that prevents the startup config from being applied. Please wait for a while to see if the config gets applied, if conditions persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM_COMMON-3-LOGGING_ERROR ### Response: (Severity: 3), (Category: MEDIA), (Description: Error while logging nvram activity), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-3-EVM_THREAD ### Response: (Severity: 3), (Category: OS), (Description: QNET process had encountered a problem in its EVM thread while wating for event. The thread will exit and retry again), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: S2681-3-MUTEX_LOCK_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The S2681 UART driver has been unable to lock access to the UART.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-MACSEC_DISABLED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-6-INFO_CID_SES_THRESHOLD_NOT_EXCD ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions on a particular Circuit ID is no longer exceeding the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE1_CODE_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE1_CODE_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DWDM-4-FORCED_MAINTENANCE ### Response: (Severity: 4), (Category: L2), (Description: If Forced Maintenance has started at a port, it means that the port was put into Transport Admin State of 'maintenance' when this activity was actually disallowed for it. Forced Maintenance ends when, either maintenance at the port is allowed again by the administrator, or when the Transport Admin State is changed back to some other rather than 'maintenance'.), (Recommended Action: A forced maintenance activity implies that there may be loss of traffic. A port should not be put into maintenance state (unless its absolutely necessary) if maintenance is disabled by the administrator. That status can be checked using show interfaces CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-MSG_SIZE_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-FILE_COMPRESS ### Response: (Severity: 3), (Category: MGBL), (Description: Unable to compress the file), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to set RSVP bandwidth limits? ### Response: To set RSVP bandwidth limits, use the 'rsvp bandwidth' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#rsvp bandwidth 100000 2000 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-INVALIDRANGE ### Response: (Severity: 3), (Category: MGBL), (Description: 'The numerical range within the token details structures is invalid'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONAUX-3-AUX_BLOCK_REG_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The ConAux Identity module has been unable to register the aux block.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-6-FIRMWARE_UPGRADE_NOT_SUPPORTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: 'V3 power module firmware upgrades are not supported at this time'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP_CLIENT-6-WARNING_WRAPPER ### Response: (Severity: 6), (Category: ROUTING), (Description: A function call failed unexpectedly - this is probably a system problem), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-BAD_VSA_TYPE ### Response: (Severity: 3), (Category: SECURITY), (Description: VSA format error found in radiusd while translating.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-6-BANDWIDTH ### Response: (Severity: 6), (Category: L2), (Description: The bandwidth for BNM Enabled Link is now known or has changed, this can occur in response to the link receiving a BNM, its configured loss threshold being exceeded, or its hold-off or wait-to-restore timers expiring. This message appears because the interface which the BNM Enabled Link belongs to has 'bandwidth-notifications log changes' configured.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_0_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser temperature greater than or equal to the high temperature alarm threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-DEBUG ### Response: (Severity: 4), (Category: L2), (Description: ELMI encountered an error using the debug service. The error message describes what operation has failed and why it failed. The error could be caused by low memory resource or programming error.), (Recommended Action: In many cases, ELMI will recover by itself. If it does not then restarting the process may help. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-3-SHELL_SPAWN ### Response: (Severity: 3), (Category: TOPOLOGY), (Description: clustermgr is spawned from shell.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMENGINE-4-TCA ### Response: (Severity: 4), (Category: L1), (Description: The specified PM TCA has been declared.), (Recommended Action: Recommended action is to repair the source of the alarm.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-6-OIR_SAVE ### Response: (Severity: 6), (Category: MGBL), (Description: This is message indicates that configuration for this node has been saved.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-ERR_RCV_PAKTYPE ### Response: (Severity: 6), (Category: ROUTING), (Description: An invalid packet was received on the specified interface (and, in the case of a LAN interface, SNPA). The packet is invalid because its type code is either unrecognized or inappropriate (e.g. a point to point IIH on a LAN interface). The packet has been ignored.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDLTLV-6-MSG_GENERIC_FUNC ### Response: (Severity: 6), (Category: OS), (Description: BCLS TLV processing hit some error condition.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN-3-MAXIMUM_PARTICIPANTS_EXCEEDED ### Response: (Severity: 3), (Category: OS), (Description: The maximum number of active participants for a shmwin window has been exceeded), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture - show logging - show shmwin summary location 0/x/CPUx - show shmwin trace all location 0/x/CPUx) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-IMDR_COMPLETION_TIMEOUT ### Response: (Severity: 6), (Category: INSTALL), (Description: As part of ISSU operation, iMDR done on LCs has timedout and an extension is being done by install ISSU infrastruture. This is an informational message that iMDR completion has not been seen.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-MULTIPLE_ENCAP_NOTSUP ### Response: (Severity: 3), (Category: L2), (Description: EVPN does not support change in encapsulation and/or mutiple encapsulation for the same route. Most likely scenario is that the remote ToR (VxLAN) and remote DCI (MPLS) are using the same ESI, or remote ToR(VxLAN) is using same ESI as local DCI pairing (MPLS). This will cause ES/EAD, EVI/EAD or MAC routes to alternate(flap) between VxLAN encap and MPLS encap.), (Recommended Action: Perform network level review, and ensure Ethernet-Segment Identifiers are truly unique and represent individual ethernet sgments.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-LOCKING ### Response: (Severity: 3), (Category: SECURITY), (Description: radiusd has either failed to obtain or release a lock.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-SYSDB ### Response: (Severity: 3), (Category: INSTALL), (Description: An error occurred when accessing the system database), (Recommended Action: This will cause failure of sysdb initialization. Please check initialization failure message for the recommended action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ASIC-1-REQUEST_RELOAD_BOARD ### Response: (Severity: 1), (Category: L2), (Description: An ASIC error has occurred multiple times and has failed to recover despite power on reset. The board has been requested to be reloaded in an attempt to clear the problem.), (Recommended Action: The output message is warning board reload request.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_SENSOR_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: The sensor in the satellite module reported a critical hi/lo sensor value against the configured threshold value.), (Recommended Action: Verify current sensor temperature values using the CLI: Copy the error message exactly as it appears on the console or in the system log. Issue the (admin)# show env command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin)# show env output, call your Cisco technical support representative and provide the representative with the gathered information. --> particularly for temp output of SAT ID. Copy the error message exactly as it appears on the console or in the system log. Issue the (admin)# show env trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin)# show env trace output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-NHDB_DELETE ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process failed unexpectedly to delete an next-hop descriptor block from the nhdb AVL tree.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-PTHREAD ### Response: (Severity: 3), (Category: OS), (Description: A call to a pthread interface failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACE_LC-1-ACE_SYSLOG_ALERT ### Response: (Severity: 1), (Category: SECURITY), (Description: ACE SPA SYSLOG message), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFDIAGBASE-3-MSG_ERROR ### Response: (Severity: 3), (Category: DIAG), (Description: The diagnostics software received a message with an unknown message type and was not able to process it. This is a serious error and indicates message or memory corruption or a bug in the software. This is not a service impacting error.), (Recommended Action: Check the log ('show logging') to determine if there are any other related error messages. Also, please check Bug Navigator ( https://tools.cisco.com/bugsearch?referring_site=btk ) to search for any bugs in this area. If the error continues, copy the error message exactly as it appears on the screen and gather any relevant information about the circumstances. Also collect the information from 'show logging' and 'show tech diagnostics' commands. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-4-WARN_STR_PRM_OOR ### Response: (Severity: 4), (Category: PLATFORM), (Description: PLATFORM FIB, PRM warning), (Recommended Action: Please check hardware resources, show cef platforms oor stats location <>. Verify whether the scale of the configuration exceeds the hardware limit. Consult your technical support representive if any further question regarding to the scale) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_0_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power greater than or equal to the high Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDM_LIB-3-SYS_PROFILE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to get the system profile information. This is an error returned from system profile component. This failure indicating that line card can not perform its basic functions, such as ping and passing traffic.), (Recommended Action: Collect required information and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_STAT_VEC_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-0 state error on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-7-CAL_CHIP_READING ### Response: (Severity: 7), (Category: MGBL), (Description: Reading value of calendar chip at offset.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-TERM_LICENSE_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The term of the license has expired.), (Recommended Action: The customer should reserve a valid license.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUMI-3-BACKUP_FPD_LOADED ### Response: (Severity: 3), (Category: INFRA), (Description: The output of 'show hw-module fpd' will show the affected image with BACK IMG state. This can happens when TUMI detects that Primary image is corrupted, so it fallback to load the backup image to recover from the failure.), (Recommended Action: Although the system will continue to run, the backup image might be of older version and it might have known issues that have been fixed on latest version. So it is critical to address the problem as soon as possible. To correct the problem, use the 'upgrade hw-module location fpd ' command to re-program the FPD image and power-cycle the affected card for TUMI to load with the upgraded image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZEN-7-SB_MBOOT_FAILURE ### Response: (Severity: 7), (Category: INFRA), (Description: Additional debug infor Secure Boot validation failure.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-DEBUG_KEY_CREATE ### Response: (Severity: 7), (Category: OS), (Description: This is a debug message that is not compiled into a customer version of the code.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RUMP-2-ERR_MEM_ALLOC ### Response: (Severity: 2), (Category: ROUTING), (Description: The requested operation could not be accomplished because of a low memory condition.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CAIBIST-3-ERR_HW_BIST ### Response: (Severity: 3), (Category: PLATFORM), (Description: BIST failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-ERR_UNSUPPORTED_GROUP ### Response: (Severity: 3), (Category: SECURITY), (Description: RADIUS does not support command authorization and command accounting.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-NODE_RESET ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that the shelf manager detected the specified node has reset. Node reload will be attempted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-4-SRAM_PARITY ### Response: (Severity: 4), (Category: PLATFORM), (Description: Parity Error detected in SRAM.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-LC_RELOAD ### Response: (Severity: 0), (Category: PLATFORM), (Description: A critical errror has been encountered that renders the system unusable.), (Recommended Action: Check if the board comes up fine after the LC reboot. If the board does not recover - it will need to be replaced.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPCP_SRVR-3-RT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The error occurs due to the failure in initialization or creation of the event manager.), (Recommended Action: The message should be provided along with following logs for further analysis. Copy the error message exactly as it appears on the console or in the system log. Issue the cmd command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the cmd output, call your Cisco technical support representative and provide the representative with the gathered information. - 'show ipcp trace location <>' - 'show ipcp channel all location <>' - 'show ipcp sap all location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBSOC-2-SVC_CRIT ### Response: (Severity: 2), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-LC_FPGA_ACCESS_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-SRV6_SID_ALLOC_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The SRv6 sidmgr API was unable to allocate a requested SID.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-IF_ALREADY_ASSOCIATED ### Response: (Severity: 3), (Category: L2), (Description: Interface is already associated with logical switch, first remove this association.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-FGID_PULSE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while sending the asynchronous pulse to MRIB FGID thread), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ASIC-3-PLA_ERR ### Response: (Severity: 3), (Category: L2), (Description: The PIO operation on PLIM ASIC failed due to a hardware or software error. The process will automatically respawn up to a fixed number of times to try and recover. %s - description of the error. %d - error number.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-P2MP_TUNNEL ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates that an error has occurred when processing P2MP tunnel updates.), (Recommended Action: The P2MP tunnel failed to program the tunnel information updates. Please try shutting down and turning on the tunnel source interface with commands (in interface config mode) shutdown and no shutdown. If the problem persists after the above two operations, please try restarting the IP Tunnel Execution Agent process with the command process restart ip_tunnel_ea location If the problem persists even after restarting process, please contact Cisco TAC and provide this message text as well as the information specified in required_info section.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-INV_MSG_RECV ### Response: (Severity: 3), (Category: SYSDB), (Description: Message type received is invalid or unknown.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-QNET_NOTIF_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that a Shelf Manager has failed to notify QNET of a node state change.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-TX_UNF_ERR_FIA11 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA11 Tx underflow error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-3-SESSION_DISCONNECT_FAILURE ### Response: (Severity: 3), (Category: MGBL), (Description: Failed to close session.), (Recommended Action: If you want to close existing session, please run 'clear line' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-7-BOUNDS ### Response: (Severity: 7), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-DYING_GASP_VRF ### Response: (Severity: 3), (Category: SNMP), (Description: Dying gasp has been enabled on a host that has VRF which is not yet configured. For such hosts dying gasp trap cannot be generated.), (Recommended Action: Ignore if this message was seen on snmp startup. Configure vrf if it not done already.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS VPN extranet feature? ### Response: The MPLS VPN extranet feature allows MPLS VPN service providers to distribute routes across VPN boundaries. It enables a VPN to share common routes with other VPNs, providing controlled access between VPNs. Extranet VPNs are implemented by configuring route targets to be imported and exported between VPNs that need to share routes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_HT1_PROTO ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an HTDP protocol error on the HT1 interface. This is logged when the HT interface experiences a protocol error on the HT interface.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_CLI-7-invalid_historical_file_format ### Response: (Severity: 7), (Category: OS), (Description: Invalid historical file format.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-LARGE_INSTALL_HISTORY_LOG ### Response: (Severity: 4), (Category: INSTALL), (Description: The install history logs are larger than the recommended size. Depending on the system and its usage, this can cause replication timeouts during later install operations. By clearing some of the old logs (from install operations unrelated to the current upgrade scenario), these detrimental effects can be mitigated.), (Recommended Action: Clear some of the install history logs from previous upgrade scenarios. Use (admin) 'show install log' to determine which logs are from previous upgrade scenarios, and then use the command (admin) 'clear install log-history oldest <>' to delete the oldest sets of logs. If this message is still seen after the clear operation, then more logs must be deleted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDBUTILS-7-INTERNAL_STATE ### Response: (Severity: 7), (Category: SYSDB), (Description: The process has got into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SIGNAL_OS ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APP_OBJ-4-INVALID_ELEM_COUNT ### Response: (Severity: 4), (Category: MGBL), (Description: The item count in the internal database is inconsistent.), (Recommended Action: Contact TAC with required_info for further diagnosis.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_LMI-3-KEEPALIVES ### Response: (Severity: 3), (Category: L2), (Description: An error occurred in the VCM call to set the keepalive state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_MGR-3-ERR_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: CCSQ manager encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-6-INFO_INSECURE_FLASH_FILE ### Response: (Severity: 6), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSMGR-3-INVALID_ARG ### Response: (Severity: 3), (Category: OS), (Description: An application called the API with invalid value.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-PAR_MERR_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Multi bit mem parity error on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE4_CODE_ERR_HIGH_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE4_CODE_ERR_HIGH interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure LDP session down switchover? ### Response: To configure LDP session down switchover, use the 'session protection for' command under the MPLS LDP configuration. R P / 0 / R S P <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-INIT_NOTIFY ### Response: (Severity: 3), (Category: L2), (Description: A CPP driver failed to initialize.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MXPDRVR-3-NCS1K_PORT_RESET_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates trunk port reset was not successful.), (Recommended Action: The casue of failure has to be analyzed. Collect the show tech logs by running 'show tech-support ncs1k detail' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-4-ERR_ASIC_SN_LINK ### Response: (Severity: 4), (Category: FABRIC), (Description: Fabricq ASIC encountered a CpuCtrl CRC/Sync error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-SHMWIN_SIZE ### Response: (Severity: 3), (Category: OS), (Description: Opened shmwin size is smaller the shmwin header size.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture - show shmwin header location 0/x/CPUx - dumpcore running shmwin_svr location 0/x/CPUx) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_ECM_REG ### Response: (Severity: 3), (Category: FABRIC), (Description: The FIA driver encountered an event connection manager error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNVGEN-3-GENERAL_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: General error in nvgen client library'), (Recommended Action: Collect the following logs and contact your technical support representative for assistance. a) Console messages b) show tech-support parser) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure a static route? ### Response: To configure a static route in Cisco IOS XR, use the 'router static' command in global configuration mode. RP/0/RP0/CPU0:router(config)#router static RP/0/RP0/CPU0:router(config-static)#address-family ipv4 unicast RP/0/RP0/CPU0:router(config-static-afi)#0.0.0.0/0 192.168.1.254 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-IM_NAME_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBIMGR-3-DEFAULT_MBI_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The default MBI is either unknown or missing. The MBI operation in progress may not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-FANTRAY_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: One or more fans on indicated fan tray measured RPM below operating level. Remaining fans in operation on this fan tray running at full speed.), (Recommended Action: Verify the failure, give CLI: (admin)# show env --> particularly fan output (admin)# show env trace If the failure does not alleviate after 30 minutes, give CLI: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP dynamic neighbors feature? ### Response: The BGP dynamic neighbors feature allows peerings to be automatically established based on a listen range rather than being explicitly configured. Incoming connections from peers within the range are accepted and dynamic neighbor entries created. It is configured with the bgp listen range command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_PORT_ERRNO ### Response: (Severity: 3), (Category: SECURITY), (Description: Error description, error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-3-LIB_NOMEM_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform Fault Manager DLL was unable to add a new fault condition due to lack of memory. This condition will cause the DLL to exit.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-4-NETIO_TO_SPP_PULSE_FAILED ### Response: (Severity: 4), (Category: OS), (Description: The Packet Classifier NetIO plugin hit an error when attempting to pulse SPP to read packets from the shared memory queue. Packets will be dropped until the connection is restored.), (Recommended Action: The problem should resolve automatically if SPP is being restarted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-6-PROVISIONING_COMPLETED ### Response: (Severity: 6), (Category: INFRA), (Description: ZTP has successfully applied the configuration fetched from the server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-TRIGGER ### Response: (Severity: 3), (Category: ROUTING), (Description: An operation failed during log trigger processing. This is not critical and IS-IS functionality should be unaffected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERRRATE_EXCEED_SLOW ### Response: (Severity: 3), (Category: FABRIC), (Description: The fabric driver encountered the annunciated error. Sysmgr will reload the node up to a fixed number of times the error is encountered, to recover. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBIPV6PROTO-3-IPSEC_HANDLE ### Response: (Severity: 3), (Category: IP), (Description: An error is encountered in handling an IP Security packet), (Recommended Action: The returned error provides the type of the error. Based on the error type, the source of the error could be identified.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-WARNING_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the ASR9K platform FIB specific code software to indicate anomolies that are not FATAL. This error is most likely caused by a temporary situation, so is unlikely to re-occur.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace all loc ). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CBC-3-CANBUS_B_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: CBC detected CANBUS B failure. This may be a serious failure, however the system may continue functioning as expected despite the failure.), (Recommended Action: Reboot the LC. If the problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSLA-7-ERR_SYSDB ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-ASYNC_ATTACH ### Response: (Severity: 3), (Category: ROUTING), (Description: CLNS encounted errors when initializing its connection with NetIO.), (Recommended Action: CLNS will restart and try to recover. In case problem re-occur than Please contact cisco-support. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_ENA-3-SSL_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP Server SSL initialization failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-6-LATE_MGMT_NODE ### Response: (Severity: 6), (Category: HA), (Description: A management node in the specified SDR came up after SDR Plane ready for that SDR was signalled.), (Recommended Action: Contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-INIT_FEAT_CKPNT_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failed to initialize feature checkpoint info. This is needed for checkpointing IPv4 and IPv6 security ACLs programmed in hardware.), (Recommended Action: No action is required. Process will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If restart din't fix the problem) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD-6-IFMGR_REPLY_FAIL ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Forwarder was not able to reply to IFMGR notification. Based on the type of notification the traffic flowing through forwarder interface might or might not be affected.), (Recommended Action: If any traffic is affected, restarting forwarder process or ifmgr process might help in fixing the issue. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-INCORRECT_COMPONENT ### Response: (Severity: 3), (Category: OS), (Description: Received unexpected message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_AHS_LOS_LANE1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EDRM_SVR-3-LOCK_NOT_RECOVERABLE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to make the mutex in consistent state results in not recoverable state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-PCIE_DEVICE_LOST ### Response: (Severity: 3), (Category: INFRA), (Description: The PCIe device could not be found, either device is lost or Inreset mode. This could be an Hw issue.), (Recommended Action: Reboot the affected hardware card to determine whether this is a transient failure. Then collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet' and 'show tech-support ctrace' commands. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT-2-CRIT_FAULT ### Response: (Severity: 2), (Category: PLATFORM), (Description: FPGA incurred unexpected error, this could be due to hardware configuration issue.), (Recommended Action: The software is not able to recover from this error automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-SFP_MUX_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: SFP mux[PCA9548] device failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-6-MAX_GLOBAL_SRVER ### Response: (Severity: 6), (Category: SECURITY), (Description: Configuration Warning..), (Recommended Action: Please reconfigure based on the recommended values.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key attributes specified in a process startup file? ### Response: The key attributes in a process startup file include\n- Process name, path, and instance count\n- Startup level (controls start order)\n- Placement (whether process can be started on any RP or LC)\n- Restarting enable (whether sysmgr should restart on failure)\n- Criticality (whether process failure should trigger node restart)\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-PAUSED_AT_CONFIG_LOCK ### Response: (Severity: 6), (Category: INSTALL), (Description: When initiating the operation, the user specified that the install infrastructure should pause before locking the config for the first time. The operation will not continue until the user indicates that it is safe to do so using the supplied command.), (Recommended Action: Either follow the command given, or attach to the operation synchronously for further details.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_IM_CNTL_SVR_BIND ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE_CLIENT-3-MQ_SEND_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to send IPC message to IKE process. Most likely casue the process is too busy), (Recommended Action: 'contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. with the exact error message seen') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN_EA-7-TLU_WRITE ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CMPP-4-ERR_MEM_ALLOC ### Response: (Severity: 4), (Category: INFRA), (Description: The process failed to allocate memory.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-L2VPN_SAFI_TO_HASH ### Response: (Severity: 4), (Category: ROUTING), (Description: SAFI to hash conversion failed due to invalid SAFI passed in), (Recommended Action: This msg is info only. At this point BGP and L2VPN will be out of sync Need process restart to achive sync) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERR_STR_RT_PRM ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, PRM error information), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>), 'show install active', 'show logging console', 'show platform' and 'show version'. Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-6-INFO_CIDRID_SES_LIMIT_NOT_REACHD ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions on a particular Circuit ID and Remote ID is no longer exceeding the maximum.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TZ-3-SYSDB ### Response: (Severity: 3), (Category: OS), (Description: One of the sysdb APIs failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-HOST_WARNING_EVENT ### Response: (Severity: 4), (Category: DRIVER), (Description: HOST has reported a warning event.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COPYMIB-3-ENTRYNONE ### Response: (Severity: 3), (Category: SNMP), (Description: An attempt to remove an entry from a queue was made, but the entry was not found.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-PROC_RESTART_JID ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-GSP_TRACE_BACK ### Response: (Severity: 3), (Category: OS), (Description: 'Observed GSP traceback on the console.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SPA_OVERTEMP_SHUTDOWN ### Response: (Severity: 2), (Category: PLATFORM), (Description: SPA temperature has risen over shutdown threshold. SPA shutdown commencing.), (Recommended Action: Verify the failure, use show env to help. If the failure does not alleviate, call your technical support representative for repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-INVALID_ENV_VAR ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Each item in the XR_INTERFACES list must be in the format :.), (Recommended Action: Check the format of the XR_INTERFACES environment variable.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-MIXED_MEMORY_SHUT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The system has attempted to power up the target node. However executing the request results chassis operating in mixed line card memory mode. Node is not powered.), (Recommended Action: Use line cards of same memory configuration in a chassis, or manually bring the card up with 'admin hw-module reload' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-5-ASIC_ERROR_ASIC_SCAN ### Response: (Severity: 5), (Category: PLATFORM), (Description: An ASIC error which requires ASIC SCAN has occured, the ASIC SCAN will be triggered.), (Recommended Action: The linecard will be booted after the ASIC SCAN is completed, save the ASIC SCAN output files on the linecard local disk, provide the files to TAC support for further debugging. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-IDB_CHKPT_CLEANUP ### Response: (Severity: 4), (Category: ROUTING), (Description: This is not critical and IS-IS functionality should be unaffected. A non-null OBJID for INTERFACE-NAME was encountered.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the router ID in OSPF and how is it determined? ### Response: The router ID uniquely identifies each router in the OSPF domain. It is used in the election of the designated router and backup designated router. The router ID is determined in the following order: 1) Explicitly configured router ID. 2) Highest IP address of any loopback interface. 3) Highest IP address of any physical interface. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-4-EXCEPTION ### Response: (Severity: 4), (Category: OS), (Description: whenever any API is fail due to NULL,any API return NULL or any API fail due to creation of memory using malloc and calloc corresponding traceback is printed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-SYSDB_ERR ### Response: (Severity: 3), (Category: L2), (Description: Some error occured in sysdb operation. The text of the message displays the failed operation with error code. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_IPV4_EA-3-ERROR2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: SSE IPV4-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-EVM_RL ### Response: (Severity: 3), (Category: ROUTING), (Description: raw_conn not available to send the packet), (Recommended Action: If the condition persist, contact the technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_FWD-4-SYSDB_ERR ### Response: (Severity: 4), (Category: ROUTING), (Description: Some error occured in sysdb operation. The text of the message displays the failed operation with error code. This message may show up during process restart or node reload events. It is not a concern unless the message is persistent.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISK_DRIVER-4-ATA_NESTED_ERROR ### Response: (Severity: 4), (Category: PLATFORM), (Description: ATA device might report these errors if it has not been shutdown properly before the RP reload. The device generally recovers of it's own.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the command to activate an installed optional package? ### Response: To activate an installed optional package, use the `install activate` command followed by the package name. For example\n```\nRP/0/RP0/CPU0:router# install activate disk0:/hfr-mpls-p.pie-3.6.0\n```\nThis command activates the package and makes it part of the running software.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_NETIO-3-ERR_INTF_INIT ### Response: (Severity: 3), (Category: L2), (Description: The PPP NetIO DLL failed to initialize the datapath for processing PPP packets on a particular interface because of an unexpected error. The message includes the exact cause of the failure. As a result, the capsulation will be unloaded from the interface and the interface will not be able to send or receive any PPP packets. One possible reason for the error is a low memory condition, particularly if the failure was in creating the interface descriptor.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration., and then remove and reconfigure the PPP encapsulation on the interface. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-MBI_VALIDATION_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that Shelf Manager has failed to validate the mbi path supplied during a boot request.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: libpcmcia_ide-5-CARD_INSERT ### Response: (Severity: 5), (Category: PLATFORM), (Description: The pcmcia flash card has been inserted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-FIFO_1_OFLOW_FIA2BR_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: FIFO-1 FIA to bridge instance-1 overflow.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-3-INTF_BANDWIDTH_LOOKUP_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The ethernet_link_oam_daemon has failed to determine the maximum bandwidth of a particular interface. This makes it impossible to apply link monitor symbol period events if the window units are symbols or frame period events if the window units are frames.), (Recommended Action: Try reentering config - it may be that the failure is transient. If that fails, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE4_CODE_ERR_HIGH_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE4_CODE_ERR_HIGH interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-4-HC_WARNING ### Response: (Severity: 4), (Category: IP), (Description: The ipv4_ma process is blocked for more than 2 Mins on some other process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check process blockage in the router.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-OOR_REGISTER_THRESHOLD_WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABVQI-1-MODE_CHANGE ### Response: (Severity: 1), (Category: PLATFORM), (Description: Fabric VQI allocator mode change alert), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-IPV6_COMPRESS ### Response: (Severity: 3), (Category: OS), (Description: IPV6 compression has failed due to some error. So,lpts entry for that IPV6 address will not be programmed. Automatic process restart will happen. It will impact traffic only for that specific IPV6 address.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_11_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEV2-1-SVC_ALERT ### Response: (Severity: 1), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_VETHER_DRIVER-3-REPORT_BER_CLEAR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The BIP error count is less than the threshold count w.r.t the configured threshold value.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-BAD_REFCNT ### Response: (Severity: 3), (Category: ROUTING), (Description: 'This indicates a internal data structure inconsistency'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-ERR_SYSDB_BAG_DECODE ### Response: (Severity: 3), (Category: MGBL), (Description: 'Failure to decode the bag.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the significance of the 'install update' command in Cisco IOS XR? ### Response: The 'install update' command in Cisco IOS XR is used to apply interim software updates, such as bug fixes and security patches, to the active software packages. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-HIGH_VOLTAGE_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected an CPAK voltage greater than or equal to the high voltage alarm threshold. The CPAK is the pluggable optics on the line cards. The voltage threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check the 'show environment voltages'. If the system voltage is normal then replace the optics with working one (if any). If the system voltage is not normal, then make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-LSP_PCALC_FAIL ### Response: (Severity: 5), (Category: ROUTING), (Description: Path calculation failed for the specified tunnel, LSP and path option.), (Recommended Action: The reported path-calculation error may be investigated if desired. This is a solicited message (controlled by logging events lsp-status pcalc-failure configuration).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MLIB-5-TABLE_PER_PREFIX ### Response: (Severity: 5), (Category: ROUTING), (Description: Error while enabling/disabling per route accounting in a table), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STANDBY-3-ERR_JOIN ### Response: (Severity: 3), (Category: IP), (Description: The HSRP process failed to start/stop receiving HSRP packets on an interface correctly. This is an internal error.), (Recommended Action: Retry the configuration on the interface. If this still fails then do the following. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Rx alignment loss on XAUI to NPU-0 interface on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_AGORA_ALM_TYPE_FOUR ### Response: (Severity: 2), (Category: PLATFORM), (Description: AGORA type four alarm.), (Recommended Action: If the problem persists, call your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEMA-3-FATAL_ERR ### Response: (Severity: 3), (Category: L2), (Description: An internal fatal error was detected in CEMA module operation), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_CLIENT-7-NO_MEMORY ### Response: (Severity: 7), (Category: OS), (Description: Not enough memory available in the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_400G_POD-3-TX_CH_HI_BIAS_CURRENT ### Response: (Severity: 3), (Category: FABRIC), (Description: The Tx POD detects a high bias current on a channel. The channel might not be functioning properly, and can cause cell drops, or corruption in the downstream.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ACL_REG_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-4-MEM_ALLOC_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: The rpl multi-version coorindator was unable to respond to a 'who has this' request and was forced to ignore the message. This will likely cause a timeout on the client side. If this was the only node with the version of the dll being requested active on it, the client will be unable to access this version. If other nodes have it, the multi-version dll operation will continue. The status of this node remains in uncertain in any case.), (Recommended Action: Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INIT-7-MBI_THRESHOLD_EXCEEDED ### Response: (Severity: 7), (Category: OS), (Description: An unexpected condition encountered. This is not necessarily an error.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-INVALID_PATHNAME ### Response: (Severity: 7), (Category: SYSDB), (Description: A process, likely to be a show command, is attempting to access a sysdb item with an incorrect path string.), (Recommended Action: *DEBUG*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-ERR_TABLE_OPERATION ### Response: (Severity: 3), (Category: ROUTING), (Description: Some type of table related error occurred.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does IS-IS advertise a default route and what is the default behavior? ### Response: The ""default-information originate"" command causes IS-IS to advertise a default route if one exists in the routing table. By default, the route is advertised only in L2 LSPs. Using a route-map or policy-map allows conditional advertisement and advertisement into L1. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-4-BAD_DOI_SA ### Response: (Severity: 4), (Category: SECURITY), (Description: The DOI field in a SA offer is needed for message parsing. SA offer with unknown DOI can't be parsed.), (Recommended Action: 'If this situation persists contact the remote peer's administrator') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSEC-2-PARSE_MEMORY_ERROR ### Response: (Severity: 2), (Category: OS), (Description: No memory left to parse show output data), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-4-DATAPATH_INPUT_LEN ### Response: (Severity: 4), (Category: OS), (Description: Failed to control input buffer length.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_0_XAUI_PLL_LOCK_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: NPU-0 XAUI PLL not locked on bridge instance-0.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-PACKET_PROCESS_FAILURE ### Response: (Severity: 3), (Category: SECURITY), (Description: This error message implies a severe error condition, likely as result of internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TAMSVCS-3-EDM_ERR_DETAILS ### Response: (Severity: 3), (Category: SECURITY), (Description: Generic Show TAM Error message - (Error Message - Error Detail - Error Description).), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_SS-7-DEBUG ### Response: (Severity: 7), (Category: HA), (Description: Debug message), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM-2-NVRAM_SIZE_ZERO ### Response: (Severity: 2), (Category: MEDIA), (Description: Possible error during sizing nvram, the NVRAM may not exist), (Recommended Action: 'Check if formatted and present') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ETHER-2-RX_LOSS ### Response: (Severity: 2), (Category: L2), (Description: The PLIM received an Rx LOS or LF on the given interface which will result in a link down. Please check the name of interface in error description. The traffic may start getting dropped after this error message.), (Recommended Action: Correct the far end or fiber to this interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ASIC-3-RW_ERR ### Response: (Severity: 3), (Category: L2), (Description: This is an internal error. PLA is unable to perform read or write operation. The process will automatically respawn up to a fixed number of times to try and recover. Please check the description . %s - description of the error. %s - failure reason.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-6-UPGRADE_IN_PROGRESS ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message indicating that Canbus Controller firmware upgrade is in progress on the specified location. The page that is being presently upgraded is mentioned in the message. This page number would be in the specified range, corresponding to the Canbus Controller partition that is being upgraded.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-2-REMOVE_PAIR_OR_NODE_ERROR ### Response: (Severity: 2), (Category: HA), (Description: Attempt to remove a node from a pair that did not containt the node or it could be an attempt to remove the pair which doesn't exist.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ILITE-3-POWERUP_RETRY_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Power up has failed, this may be a program level error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_LCAC-4-SHOW_WARNING ### Response: (Severity: 4), (Category: ROUTING), (Description: The show thread could not acquire the mutex to service the show request. The main thread in te_control may be busy/blocked/hogging while holding That mutex.), (Recommended Action: Try to run the show command again. If the error reoccurs, then check the state of the te_control process (show process te_control). If thread number 1 is blocked for an extended period of time, contact your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-4-DEBUG_BACKUP_LOG_FAILED ### Response: (Severity: 4), (Category: L2), (Description: This is an error message in the NPU Driver to indicate that it failed to take up the back up npu logs on reload due to the specified reason.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-6-ENFORCE_INC ### Response: (Severity: 6), (Category: LICENSE), (Description: The licensed feature is enabled with appropriate licenses.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-3-IM_INIT ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the TCP process try to do initialization with ifmgr), (Recommended Action: The process will attempt to recover from this situation by restarting or retrying. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR-6-NOT_SUPPORTED_CHASSIS_TYPE ### Response: (Severity: 6), (Category: PLATFORM), (Description: Certain eth_server commands are not supported on the 2 slot chassis.), (Recommended Action: No action is required) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_BAD_INTEGER ### Response: (Severity: 4), (Category: SYSDB), (Description: The user entered integer in unrecognized format or out of range of current integer data type.), (Recommended Action: Correct input value and run command again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GIRO_ETHERLIKE-3-TX_DISABLE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: L2VPN Mgr has signalled at the remote AC has changed state. Due to this the local interface has been enabled/disabled in the TX direction if supported, or enabled/disabled in both directions otherwise.), (Recommended Action: If the remote AC has changed state then this message is expected. If the remote AC hasn't changed state and this condition isn't expected then this may indicate a problem, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL_SIP700-3-FPD_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The CPU Controller FPGA FPD agent failed to initialize. If this error is encountered the CPU Controller FPGA could not be upgraded. The failure should not have an adverse effect on the card's normal operation. %s - description of the specific failure encountered %s - error detail, if appropriate), (Recommended Action: This error is unlikely to occur by itself nor is it likely to be the root cause of the problem. Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers CPUCtrl ltrace location <>/<>/CPU0 command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers CPUCtrl ltrace location <>/<>/CPU0 output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-4-BUS_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: A PCIe bus error has occurred. The message has the device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPP_LTH_FIFO_MBE ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPP packet length FIFO multiple bits error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-7-DESTROY_NOTEMPTY ### Response: (Severity: 7), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-3-MGR_ACTIVE ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: When VPDN Manager (vpdn_mgr) is either the active process or RPFO occurs, the process initializes active-only services. Something has failed in this proceedure and may prevent VPDN from functioning.), (Recommended Action: Allow VPDN Manager to restart. You can further remove and re-add 'vpdn' configuration. If the problem persists, contact Cisco support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-STATS_REG ### Response: (Severity: 3), (Category: FORWARDING), (Description: Failed to register for stats collection. show tunnel-ip X may not display statistics correctly.), (Recommended Action: Restart tunl_gre_ma.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMORB_XMLAGENT-6-RESTART_WAIT_TIMEOUT ### Response: (Severity: 6), (Category: MGBL), (Description: The xmlagent process is restarting while wait for config operation completion times out. Commit database info may lose), (Recommended Action: just information message, no action is required) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure BGP to advertise a default route in IOS XR? ### Response: To advertise a default route in BGP on IOS XR, you use the 'network' command under the BGP address family configuration. router bgp 65000 address-family ipv4 unicast network 0.0.0.0/0 commit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDS_PRODUCER_LIB-3-MEMORY ### Response: (Severity: 3), (Category: OS), (Description: The client library has failed to aquire the required amount of memory.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_MCAST_EDM-5-SYSDB_INIT_FAILURE ### Response: (Severity: 5), (Category: ROUTING), (Description: The VIKING-MCAST library encountered internal error during SysDB init setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp multipath as-path' command in IOS XR BGP configuration? ### Response: The 'bgp multipath as-path' command is used to enable multipath load balancing over paths with different AS paths. It is similar to the 'bgp bestpath as-path multipath-relax' command, but it allows the installation of multiple paths in the forwarding table even if they have different AS paths. This command is useful in scenarios where there are multiple valid paths to a destination and load balancing over all of them is desired. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_EVM_CREATE ### Response: (Severity: 4), (Category: L2), (Description: PPP MA failed to create its Event Manager which is a critical resource for the operation of the process. This error may be caused by low memory resources. The process will abort and be restarted in an attempt to recover.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-FLEX_ALGO_ENABLED ### Response: (Severity: 3), (Category: ROUTING), (Description: Flex-Algo defintion is consistent between routers in the area and can be used), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-PKTDROP_WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: An input packet was dropped for the specified reason.), (Recommended Action: Such errors are possible during raw_ip restarts. If seen otherwise, these errors should be reported to SUPPORT.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-ULOOP_SID_LIMIT_EXCEEDED ### Response: (Severity: 6), (Category: ROUTING), (Description: ISIS was unable to provide microloop avoidance for a node or prefix because the platform or linecard does not support the needed SID stack depth.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE fast reroute (FRR) feature? ### Response: The MPLS TE fast reroute (FRR) feature provides link and node protection for MPLS TE tunnels. It enables fast traffic recovery upon link or node failure by using pre-signaled backup tunnels that bypass the protected resource. FRR is enabled on a per-tunnel basis and activated when the primary tunnel fails. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_LQ_OFLOW_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue overflow error on XAUI 1 LQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_EVM_CREATE ### Response: (Severity: 7), (Category: FABRIC), (Description: Ingressq Event Manager create error), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the ingressq driver is up and running by executing the following command at the CLI of the active RP: 'show process ingressq location < >' If it is still non-operational, enable the following debugs of the ingressq driver process: error Errors in the driver fatal Fatal errors which cause driver to exit info All informational events init Initialization events and restart the driver by executing the following command at the CLI of the active RP: 'process restart ingressq location < >' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-FGID_ADD_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-3-MSG_INVALID_HEADER ### Response: (Severity: 3), (Category: SERVICES), (Description: 'The message packet header got corrupted ' 'and invalid header received'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-CCI_INTR_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver cannot initialize the CPLD interrupts with CCI infrastructure. The node may not be able to handle CPLD interrupts.), (Recommended Action: Collect all the event logs and 'sh controller fabric trace driver all location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFDIAGBASE-3-PKT_ERROR ### Response: (Severity: 3), (Category: DIAG), (Description: A packet processing error occurred. The diagnostics software attempted to retrieve a packet and an error occurred while doing so. This is not a service impacting error.), (Recommended Action: Check the log ('show logging') to determine if there are any other related error messages. Also, please check Bug Navigator ( https://tools.cisco.com/bugsearch?referring_site=btk ) to search for any bugs in this area. if the error continues, copy the error message exactly as it appears on the screen and gather any relevant information about the circumstances. Also collect the information from 'show logging' and 'show tech diagnostics' commands. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-1-PCH_PROCHOT_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: PCH Prochot error detected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XRV9K_FIB-3-INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The specific error is encounered during IOX XRv 9000 FIB initialization.), (Recommended Action: Please collect output of the following commands: show log show process blocked location <> show process fib_mgr location <> show cef platform trace all all location <> show process dpc_rm_svr location <> show controller dpc rm trace init location <> show controller dpc rm trace error location <> show controller dpc rm trace event location <> show controller dpc rm trace internal location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-1-ERR_CCTL_POWER_FAULT ### Response: (Severity: 1), (Category: FABRIC), (Description: Fabric FPGA detects the specified power fault. If the failure is for the LTC2978 device, then this error is due to the failure of the cctl library function call.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_AIB_ZERO_ALL ### Response: (Severity: 3), (Category: ROUTING), (Description: We were not able to set all cached adjacencies to zero when we got ELIBBAD from AIB), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-BUNDLE_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install activate commit command in IOS XR? ### Response: The 'install activate commit' command is a combination of 'install activate' and 'install commit'. It activates the specified packages and commits them as the persistent set in a single step. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_0_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_0 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-SETPRIO_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: Changing acctd priority failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-RELEASE_LOCK_FAILED ### Response: (Severity: 3), (Category: L2), (Description: CPP driver failed to release shared memory lock.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-SYSADMIN_VM_FATAL_EVENT ### Response: (Severity: 3), (Category: DRIVER), (Description: SysAdmin VM has reported a fatal event.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_VPLS-3-ENGINE_INIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the platform VPLS process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_FWS_INIT ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to initialize its storage for forward-referenced interfaces. This is may be due to lack of resources or an internal error (the error message will indicate which). It requires a restart of the process for recovery.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-2-CLUSTER_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The cluster is configured without the necessary cluster license.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-6-TRANSCEIVER_INSERTED ### Response: (Severity: 6), (Category: L2), (Description: This informational message indicates that the optic interface module was inserted on the given interface.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-3-SYSDB_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The sysdb error occurs for the following reasons - SPA Infrastructure SysDb error - Event manager not created - Trying to use uninitialized debug event - Unable to get CPU nodeid), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD-3-INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message during initializing one of FPD processes.), (Recommended Action: File a DDTS) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_ASR9K_NSR_PACKET-3-EVENT_TRACE_INIT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message tells is the ltrace initialization for event traces has failed and prints the error string.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-MAX_PFX_LIMIT_CHANGE ### Response: (Severity: 4), (Category: ROUTING), (Description: User has configured a maximum-prefix limit which is higher than the previous maximum prefix limit. The current accepted prefix count matches the old maximum-limit. Its possible that certain prefixes were dropped previously. To rebuild state for those prefixes upto the new maximum-limit, user needs to reset the session if neighbor does not support route-refresh), (Recommended Action: Reset the neighbor session if neighbor does not support route-refresh) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-2-CPU_FAILURE_ALERT ### Response: (Severity: 2), (Category: PLATFORM), (Description: One or more the CPUs in the card is not detected or having errors.), (Recommended Action: Please report the problem to your Cisco technical representative:) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-6-HW_MOD_PROF_ACL_FRAG_MANDATORY ### Response: (Severity: 6), (Category: FABRIC), (Description: This message will typically occur when the fragment filter field is missing from the IPV6 User Defined Key.), (Recommended Action: Add the fragment filter to the IPV6 User Defined Key for this linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-DEV_CPAK_OPTICS_PORT_UNSUP ### Response: (Severity: 2), (Category: PLATFORM), (Description: A CPAK Module not supported for the port error was detected during CPAK initialization. A CPAK Module not supported for the port error is reported when Optics is not supported on the port. The CPAK is the pluggable optics on the line cards. CPAK initialization may happen when linecard boots up, CPAK OIR and line card process restart. Traffic will not be impacted by this error.), (Recommended Action: Verify that the CPAK Module is supported for the port. Replace the CPAK with a working one (if any) to isolate bad optics. Check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the command 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-4-QUEUE_RED ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is a warning indication that a queue length is growing in a dpa client), (Recommended Action: Please collect the console log, OFA traces (show dpa trace loc <>), Also notice if the error message is transient or persistent.Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: MGBL), (Description: 'The system has run out of memory'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-4-WINDOW_TOO_SMALL ### Response: (Severity: 4), (Category: L2), (Description: There is an allowed range for window size in milliseconds. When window size is specified in frames or symbols, its length in milliseconds depends on the maximum bandwidth. In this case, the configuration results in too short a window. The mimimum window size is being used for this event instead.), (Recommended Action: Consider changing the relevant configuration (i.e. the window size).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_TOPAZ-3-ERR_QAD_NOTIF ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to get the qad notification of queue depth above or below watermark. This normally indicates there is some issues with the qad queue %p - QAD queue id), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_AIB-3-SHM_PIT_NULL ### Response: (Severity: 3), (Category: PLATFORM), (Description: PIT shared memory is NULL, couldn't open shared memory.), (Recommended Action: Please contact TAC Support Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-4-OOM_STATE_THROTTLE ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-FM_ADD_FEAT2GRP ### Response: (Severity: 3), (Category: OS), (Description: An internal fm add feature to group function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-OLD_CMD ### Response: (Severity: 4), (Category: ROUTING), (Description: The command has been replaced by a newer command.), (Recommended Action: Use the new command inidicated in the message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-4-PCI_NOLATCH ### Response: (Severity: 4), (Category: PLATFORM), (Description: Error was observed on the system PCI bus for which detailed infromation was lost due to more errors or some other reason.), (Recommended Action: Check if there are any asic errors or asic drivers restarts observed around this error. Check if process 'pci_bus_mgr' is up and runnning. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-INIT_FAIL ### Response: (Severity: 3), (Category: MEDIA), (Description: Error while trying to init, sanitize nvram during NVRAM initialization.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The PCIe server has detected an error condition. The message has the error information.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCI_HAL_SATORI-7-PDMA_DEBUG_INFO ### Response: (Severity: 7), (Category: PLATFORM), (Description: %s- debug info. %s- function name. %d- line number.), (Recommended Action: debug info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-6-QUEUE_GREEN ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an indication queue length is back to normal for ofa client), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEATURE_AGENT-4-INIT_FAILED ### Response: (Severity: 4), (Category: INFRA), (Description: An error was encountered while the Feature Agent was initializing. Feature capability information may not be available. The error message contains details about the source of the error.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-BAG_CREATE_ERR ### Response: (Severity: 4), (Category: SYSDB), (Description: Error creating bag), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-7-CIS_DATA_PARSING_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: CIS data parsing error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-4-ERR_THREAD_MUTEX_UNLOCK ### Response: (Severity: 4), (Category: FABRIC), (Description: FSDB encountered an error while locking unlocking a mutex to access the specified shared resource. The operation related to the resource may be affected while the process continues to run normally.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_13_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_13 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-WARN_ACCESS_IF_SES_LIMIT_REACHED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions on the access interface has reached the configured maximum.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-KDUMP_TIMEOUT ### Response: (Severity: 3), (Category: DRIVER), (Description: The creation of the host kernel core file has timed out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SESVI_EA-3-INITFAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of the SESVI EA process on a particular node. The process will be restarted. Until the process starts successfully, any SESVI interface located on that node will not come up. (If there is a standby node the interfaces should come up on the standby).), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAA-3-INVALID_DEBUG_FLAG ### Response: (Severity: 3), (Category: SECURITY), (Description: The debug flag specified is not supported.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_LOCAL-3-PROC_INIT_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A failure occurred during initialization with a necessary service for the process. The process is unable to run.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-BACKUP_FPD_LOADED ### Response: (Severity: 3), (Category: DRIVER), (Description: The Backup Set of FPD images on CCC Bootflash has been loaded on the indicated card. The output of 'show hw-module fpd' will show the affected images with BACK IMG state. This can happens when CCC detects that one of the Primary image set is corrupted, so it fallback to load the backup image set to recover from the failure.), (Recommended Action: Although the system will continue to run, the backup image set might be of older version and it might have known issues that have been fixed on latest version. So it is critical to address the problem as soon as possible. The output of 'show hw-module location fpd' will identify the image with the problem with NEED UPGD state and it will have missing Programmed version. To correct the problem, use the 'upgrade hw-module location fpd ' command to re-program the FPD image and power-cycle the affected card for CCC to load with the upgraded image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-3-GET_MY_NODEID_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to get the nodeid which results in exit of the DSC process , the process will respwawn itself.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the dsc process is up and running by executing the following command at the CLI of the active RP: 'show process dsc' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BVI_MA-3-INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: An unrecoverable error has happened while initializing BVI MA process. bvi_ma will be restarted automatically. BVI interfaces may get created later.), (Recommended Action: The process should recover automatically. It is suggested to collect 'show tech-support l2vpn' and to call Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMS-7-REG_SEC_CONTEXT_EXISTS ### Response: (Severity: 7), (Category: SYSDB), (Description: Sysdb is attempting to add a registration that already exists in its secondary registration context. This will cause a sysdb server restart.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-BADDLSYM ### Response: (Severity: 3), (Category: MEDIA), (Description: Cannot resolve symbols for the interface function. Probably function not defined in DLL. Will exit to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFL-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that a failure has occured in the OBFL process, but there is not corresponding error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-CALLING_PLATFORM_RELOAD_NODES_ALL ### Response: (Severity: 4), (Category: INSTALL), (Description: The install manager needs to call the platform API to reload the router to complete the parallel install operation. If the call fails, the user may have to call: reload location all in admin mode.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-6-ERR_ASIC_EOP ### Response: (Severity: 6), (Category: FABRIC), (Description: Fabricq ASIC encountered a Unicast/Multicast Unexpected/Missing End Of Packet error), (Recommended Action: If the problem persists, *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-EVM_FD ### Response: (Severity: 3), (Category: ROUTING), (Description: A call to get the file descriptor associated with an event manager connection failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-RSPI_PROT_SEQ_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: RxSPI protocol sequence error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-NODE_RESET_BRINGDOWN ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is being reset because it failed to detect heartbeat pulses. Please check for any reboot reasons for the node printed on the console or shown in the show reboot history reverse CLI.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-6-PA_FF_RESET ### Response: (Severity: 6), (Category: OS), (Description: An internal error was detected when trying to reset the BCDL group for the LPTS Port Arbitrator/Flow Forwarder.), (Recommended Action: Restarting lpts_pa may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-3-CONFIG_REMOTE_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The set of primary or secondary VLANs on a bundle interface of the iccp-group does not match the secondary or primary set of VLANs for the same bundle interface on the other member of the redundancy group.), (Recommended Action: Verify the configuration under l2vpn redundancy. Ensure that the primary and secondary set of VLANs for a specific bundle interface is the reciprocal of the primary and secondary set of VLANs on the same bundle interface on the other member of the redundancy group.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GIRO-4-GLOBAL_OPERATION_STALLED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: An Interface Manager or Config Manager operation has been retrying unsuccessfully for and extended period of time - retries will continue until the operation is successful or the operation is cancelled. This issue is most likely to occur if there has been an attempt to configure the feature beyond supported scale or with other invalid parameters. Until this is resolved then the programming of the affected interface(s) may be incorrect.), (Recommended Action: If this is seen following a change in system configuration that results in the feature exceeding the supported scale then remove the configuration and restart this process. If the system has not been configured beyond the supported scale then seek support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-BGCOPTIONMISSING1 ### Response: (Severity: 3), (Category: MGBL), (Description: 'The input is invalid. The calling function and the command are displayed'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR_HELPER-4-SYSDB_ERROR ### Response: (Severity: 4), (Category: MEDIA), (Description: An unexpected sysdb error condition encountered.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-PROCHOT_INTR_ENABLE_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: PCH Prochot intr enable failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-3-ERR_INIT_MODULE ### Response: (Severity: 3), (Category: TOPOLOGY), (Description: System Admin Manager failed to initialize specified module when system is starting.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-4-ERR_SYSDB_DISCONNECT ### Response: (Severity: 4), (Category: ROUTING), (Description: The process failed to disconnect from system database. The error will not affect operation but does indicate that a programming error has occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_COM_IFIB-3-NO_CONFIG ### Response: (Severity: 3), (Category: OS), (Description: No configuration for IFIB flow handling was found. Default characteristics will be used for all packets.), (Recommended Action: A healthy running box, should not hit this point. Provide the following log: Collect Console logs and output of -show memory summary -show memory heap summary all -show tech-support lpts) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-OVERSIZED_UPDATE ### Response: (Severity: 4), (Category: ROUTING), (Description: An attempt was made to allocate an oversized message during update generation. This is usually due to the presence of large sized attributes for one or more prefixes. When such an error encountered, a Withdraw message is generated for the prefix under consideration.), (Recommended Action: Please check the attributes of the prefixes in the afore mentioned table.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-INTERNAL_TUPLE_ERROR ### Response: (Severity: 3), (Category: SNMP), (Description: This is an internal software error. Tuple-Type: The retrieved datatype for the given SysDB tuple does not match the expected datatype. Bad-host: Received a tuple for the snmp-server host CLI command, but could not parse it. Unpack: Failed to decode/unpack the retrieved SysDB tuple value.), (Recommended Action: Try to re-apply the config , if still seen the error message contact technical suppport representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-NULL_PTR ### Response: (Severity: 4), (Category: INSTALL), (Description: Unexpected parameter value passed to function.), (Recommended Action: An internal error has occurred in an application that has caused it to pass invalid data to the boot-variable infrastructure. The operation in progress may not be carried out. Please retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-6-OPCODE_NOT_SUPPORTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that a client of the LDA server requested an operation that is not implemented for this card type. The message may provide informational value, if there are other unexpected behaviors observed.), (Recommended Action: No action is required for this message. It only provides information that an unsupported message has been sent.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-CHKPT_OP_FAILED ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: A check point operation failed in packet manager.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-6-RX_ALL_CH_LOP_ERR ### Response: (Severity: 6), (Category: FABRIC), (Description: The Rx POD detects LOP signal on all channels. Please check sh controllers fabric pod health <> <> <> to confirm the same.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLEAR-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: MGBL), (Description: 'Memory allocation failure'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VEEA-1-INVALID_MTU ### Response: (Severity: 1), (Category: PLATFORM), (Description: A failure occurred during the setting up MTU on the interface. Platform allows only 3 MTU values to be setup on the interfaces within an NPU. Configure MTU on the interfaces with allowed values.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_23 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-FILE_OPEN ### Response: (Severity: 3), (Category: MGBL), (Description: Unable to open the file), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-FIA2NPU_0_PKT_MAXLEN_ERR_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet maximum length error on FIA to NPU-0 interface on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-ERR_THREAD_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: NPU driver failed to create the identified thread during driver initialization.), (Recommended Action: The driver will escalate the error to the Fault Management (FM) entity for further action. Verify that the driver will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-3-PCI_BUS_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A PCI bus error has occurred. The message has the device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-4-WARNING ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: A warning codition has been detected.), (Recommended Action: If this message is not repeating, no actions are needed. If this message recurs, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSVP-5-BAD_RSVP_MSG_RCVD_AUTH_DUP ### Response: (Severity: 5), (Category: ROUTING), (Description: The router received an RSVP message with an authentication sequence number that has already been seen. RSVP discarded the message because an untrusted source may be (unsuccessfully) attempting an RSVP message replay attack.), (Recommended Action: If you can verify that the source is trusted, it is possible that the source has rebooted and its clock has gone backward in time; in this case, the source should be configured to synchronize its clock with an NTP server. Otherwise, the sender could be an untrusted source (unsuccessfully) attempting an RSVP message replay attack; try to find and disable the untrusted source.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBUS-7-SVC_INFO_DUMP ### Response: (Severity: 7), (Category: PLATFORM), (Description: mbus debug information being displayed for debug purpose.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDPSNMP-3-INIT ### Response: (Severity: 3), (Category: SNMP), (Description: This is indicates the udp process Initialization failed . This could be due to a low memory condition or an internal software error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-2-FPGA_IMG_FAIL ### Response: (Severity: 2), (Category: L2), (Description: The PLIM is running wrong/unsupported FPGA image. This could be caused due to 1. Previous FPD updgrade failure. 2. Card is moved from 200G slot to 400G slot %d - 3/4), (Recommended Action: Upgrade the FPGA with FPD CLI. 'admin upgrade hw-module fpd fpga[3/4/5] location 0/x/CPU0') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_OPM-4-MEMBER_INCONSISTENCY ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: An ICCP redundancy group which is being used for satellite multi-chassis redundancy has been given multiple members.), (Recommended Action: Correct the misconfiguration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure static routes in MPLS L3VPN VRF? ### Response: To configure static routes in an MPLS L3VPN VRF, use the 'vrf' command in router static configuration mode. router static address-family ipv4 unicast vrf MyVRF 0.0.0.0/0 192.168.1.254 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL_SIP700-0-INTR_INIT_FAILURE ### Response: (Severity: 0), (Category: PLATFORM), (Description: The CPU Control driver failed to initialize interrupt processing. The effect is that the line card may not function or may not function appropriately. The CPU Control driver provides low level services on the SIP 700 Line Card (LC). These include, among other things, access timeout interrupt services and bus parity error interrupt services. If these services are not available then the driver process is exited, respawned and the initialization retried. The CPU Control driver is a mandatory process. If the initialization continues to fail after several retries the LC will not properly boot and will reset itself. This error is generally indicative of a larger LC-wide problem. %s - description of the specific failure encountered %s - error detail, if appropriate), (Recommended Action: This error is unlikely to occur by itself nor is it likely to be the root cause of the problem. Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers CPUCtrl ltrace location <>/<>/CPU0 command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers CPUCtrl ltrace location <>/<>/CPU0 output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-INIT_EVENT_BLOCK_FAIL ### Response: (Severity: 3), (Category: L2), (Description: event_block failed. This indicates process has encountered unexpected error while waiting for events.), (Recommended Action: No action is required. Process will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If restart din't fix the problem) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-2-NORESOURCE ### Response: (Severity: 2), (Category: ROUTING), (Description: The requested operation could not be accomplished because of a low memory condition.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information as given in the required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-4-QFP_FAILURE_SPI4_INTERRUPT_CNTRL ### Response: (Severity: 4), (Category: L2), (Description: Failed to enable/disable interrupts on the specified SPI4 link), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers QFPCPUBridge trace <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers QFPCPUBridge trace <> output, call your Cisco technical support representative and provide the representative with the gathered information. before reloading the line card If this problem persists, reload the line card using hw-module location <>/<>/CPU0 reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-3-CORRUPT_FILE ### Response: (Severity: 3), (Category: MEDIA), (Description: The specified File is corrupted on Primary Boot Device.), (Recommended Action: Run 'install verify packages repair location <>' for respective node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_OAM-2-IM_ERR ### Response: (Severity: 2), (Category: L2), (Description: Error in IM(Interface Manager) operation %s - Type of error %s - reason for the error This error happens on the LC with ATM interfaces), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. restart the atm_oam process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-5-BOARD_RESTART ### Response: (Severity: 5), (Category: PLATFORM), (Description: The FPGA Manager api for resetting the board via a control register has been called by the process with the specified PID.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_LMI-6-CODEP_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: LMI parameters N392 and N393 are co-dependent - they must obey the rule N392 <= N393. Sometimes when one is changed the other must be changed as well to keep the protocol functioning properly.), (Recommended Action: None. This is not an error, just a notification.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-6-GRACEFUL_SHUTDOWN ### Response: (Severity: 6), (Category: ROUTING), (Description: Informs user of graceful shutdown events. User needs to be aware of these activities.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-BAGS_UNREG_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR-7-ERR_EVENT_CONN_OPEN ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to open connection with event manager. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-MPLS_LABEL_OR_TUNNEL_OP_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: An attempt to do an mpls operation failed.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-4-UNSUPPORTED_FEATURE ### Response: (Severity: 4), (Category: OS), (Description: The feature is not supported by OBFL.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-5-PORT_CONTROL_UPDATE ### Response: (Severity: 5), (Category: L2), (Description: Dot1x port control host mode is updated.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_REX-3-MEM ### Response: (Severity: 3), (Category: SERVICES), (Description: During processing of a new or updated diversion, insufficient memory was available. The diversion information was not applied, and future updates may also not be applied correctly.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Once the memory condition is resolved, execute the command 'proc restart rspp_rex' for the node where the error message originated to ensure all diversion information is correctly set up.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MXPDRVR-3-NCS1K_REPROV_ABORTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Provisioning of specified slice has aborted during hitless restart due to an issue in accessing the hardware. Current priovisioning state of the slice is unknown.), (Recommended Action: The casue for the provisioning failure has to be analyzed. Collect the show tech logs by running 'show tech-support ncs1k detail' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATS_INFRA-3-ERR_STR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in stats infra component. The error string gives the reason for the error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-ERROR_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: CLNS could not initialize its error code. CLNS will work, but error messages won't be user friendly!), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-PLATFORM_FILE ### Response: (Severity: 3), (Category: OS), (Description: Problem opening/reading from the platform shmwin file.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Check the platform shmwin file under /etc/platform_shmwin. Include the /etc/platform_shmwin file information in the ddts.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-PA_ERROR_MSG ### Response: (Severity: 4), (Category: PLATFORM), (Description: Syslog PA errors.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-3-ERROR_RESTORE_LOG_ENCODE ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GETMEDIA-6-DEVFILE_READ_FAILED ### Response: (Severity: 6), (Category: MEDIA), (Description: The qsm application device file was unavailable. Default boot device will be used.), (Recommended Action: This message is informational only. Report this message to TAC only if the router malfunction after the message. Capture the console log and show media output) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_IPV6_EA-3-ERROR1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: DNX IP-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COREHELPER-6-START ### Response: (Severity: 6), (Category: OS), (Description: dump_core or dump_core_suspended will start.), (Recommended Action: This message is information only. dumping of core will start now.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-3-ERROR ### Response: (Severity: 3), (Category: L2), (Description: A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card whee the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef trace location <> show cef platform trace common all location <> show cef platform trace ipv4 all location <> show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-UNKNOWN_CHASSIS_ID ### Response: (Severity: 3), (Category: PLATFORM), (Description: The value read from the EEPROM does not match any of the known Controller/platform type values.), (Recommended Action: Please check the EEPROM programming. 'show diag eeprom-info' in admin mode gives a raw dump of the EEPROM data. Refer EDCS-137763 to interpret the data to check if the Controller/Platform type is programmed correctly or not. If the Controller/Platform type is incorrect, the unit will have to be RMA'd to reprogram the EEPROM correctly. If the Controller/Platform type is correct, EEPROM read is failed due to unknown reason, Its Recommended to Hard OIR of the card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE7_LANE_CRC_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE7_LANE_CRC_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-SHMEM_INIT_FAIL ### Response: (Severity: 3), (Category: MEDIA), (Description: Error while trying to create/open a shared memory file for nvram backup during NVRAM initialization.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-NSF_CHKPT_TABLE_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: An unexpected error occurred whilst IS-IS was accessing the specified checkpoint table. If this error occurs during an NSF Cisco restart then that NSF restart may be aborted in favour of a traditional restart. If this error occurs during normal operation then the relevant checkpoint table may not be correct, and a subsequent NSF restart may not succeed. The error may be caused by a low memory condition or through programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-OUT_MEM_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected an output memory error on link 2), (Recommended Action: This alarm is transient and should auto-clear when error condition is resolved. If the alarm doesn't clear, then please reload the card using command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_5_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MCAST_NETIO_DEBUG-6-TERM_ERR ### Response: (Severity: 6), (Category: ROUTING), (Description: Internal non-serious error. Mcast netio debug library termination failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-DBG_TCAM_LIB_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver cannot initialize the Debug TCAM library. The node may be not be able to use the debug TCAM to debug cell flows through the fabric ASICs.), (Recommended Action: Collect all the event logs and 'sh controller fabric trace driver all location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAAD-3-PASSWORD_FILE_PERMISSION ### Response: (Severity: 3), (Category: MGBL), (Description: This error comes when there is issue with spawning the bash, bash shell itself is not present), (Recommended Action: The issue should be recovered when retrying login, if this message keeps on coming please collect required log) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_SKYWARP_NETIO_LIB-4-FINT_IDB_NOT_FOUND ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The FINT idb is not yet created in netio. This could be a transient condition.), (Recommended Action: Please capture the following information and check if FINT is created in one of the outputs on the node. If so, it was a transient error. show netio trace all loc <> sh netio idb FINT loc <> sh im trace interface-existence loc <> Else, please capture the following information and if traffic loss also is being observed Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. show logging show proc blocked sh im trace loc <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-3-ERR_IM_CAPS_REMOVE ### Response: (Severity: 3), (Category: L2), (Description: CDP could not uninstall the CDP capsulation on the specified interface and hence CDP may be in an inconsistent state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-6-HW_INIT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the LC hardware in the platform L2FIB component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-7-MSG_CHAN_CONN_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to attach handler for sync messages.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATSD-5-CFG_REG_FAILED ### Response: (Severity: 5), (Category: MGBL), (Description: Any updates that are made to the Service Accounting statistics polling interval configuration will not be implemented by this collector. The collector will continue to use whatever statistics polling interval was configured at the time this message was seen.), (Recommended Action: Restart the affected collector process before applying any new Service Accounting configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_6_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_6 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC8 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-TABLE ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred that prevented the FIB from working with multiple tables.), (Recommended Action: Try restarting the FIB process to see if the problem goes away. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XBAR-7-ERR_EXIT ### Response: (Severity: 7), (Category: PLATFORM), (Description: An error occurred in crossbar driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-0-CPU_ERR1 ### Response: (Severity: 0), (Category: PLATFORM), (Description: Indicates non-fatal error (operating system or firmware action required to contain and recover). This error message is thrown after observing non-fatal error at the LC CPU.), (Recommended Action: Reload the LC that has the problem. If problem persists, contact support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-6-MLACP_BDL_SYSID_IGNORED ### Response: (Severity: 6), (Category: L2), (Description: When running mLACP on a bundle, the system ID must be common on both devices, so cannot be configured on a per-bundle basis.), (Recommended Action: Remove the system id configuration, as it has no effect when running mLACP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-5-OIR_INSERTED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-3-MGR_INIT ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: When 'vpdn' configuration is first added, the VPDN Manager (vpdn_mgr) process starts and initializes. Something has failed in this proceedure and may prevent VPDN from functioning.), (Recommended Action: Allow VPDN Manager to restart. You can further remove and re-add 'vpdn' configuration. If the problem persists, contact Cisco support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-3-ERR_IPV6_REGISTRATION ### Response: (Severity: 3), (Category: L2), (Description: CDP registration with the IP address library has failed. This means that IPv6 address information for interfaces local to this node will not be included in outgoing CDP packets. The neighboring devices will not see the IPv6 address information for this router's interfaces.), (Recommended Action: Restarting CDP as the address consumer, or the ipv6_ma as the address provider on this node may rectify the problem. proc restart cdp location or proc restart ipv6_ma location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-LINUX_LOOPBACK_ADDRESS_RESYNC_FAIL ### Response: (Severity: 4), (Category: INFRA), (Description: XLNCd is responsible for keeping the networking stacks for IOS XR and Linux synchronized. Certain IOS XR interfaces only have L3 reachability, provided by having their IP addresses added to the Linux loopback device in the network namespace corresponding to the IOS XR VRF the address is configured in. This message indicates that XLNCd was unable to query Linux to determine the current set of Linux loopback IP addresses after a process restart. This may result in the wrong set of IP addresses being set on the Linux loopback device, for example if the required set of IP addresses changed while XLNCd was restarting.), (Recommended Action: If the system is experiencing memory exhaustion, resolve other issues that may be causing this failure state, then attempt to recover by restarting XLNCd: process restart xlncd If the problem persists, inconsistencies between Linux and IOS XR can be observed by comparing the output of show linux networking interfaces address-only for the IOS XR VRF and run ip netns exec ip addr show dev lo IPv4 addresses that are missing from Linux can be added using run ip netns exec ip addr add dev lo Extra IPv4 addresses can be removed from Linux using run ip netns exec ip addr del dev lo IPv6 addresses that are missing from Linux can be added using run ip netns exec ip -6 addr add dev lo Extra IPv6 addresses can be removed from Linux using run ip netns exec ip -6 addr del dev lo Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_LASER_CASE_TEMP ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_IM_BULK ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-3-MISS_MEM_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: Missing mem_info while processing error interrupt.), (Recommended Action: Error at the memory location will not be corrected in this case. Need add this information to parser generated file *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACE_LC-4-ACE_SYSLOG_WARNING ### Response: (Severity: 4), (Category: SECURITY), (Description: ACE SPA SYSLOG message), (Recommended Action: 'If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFD_HELPER-5-SYSADMIN_COMMIT ### Response: (Severity: 5), (Category: MGBL), (Description: The sysadmin configuration was modified.), (Recommended Action: No futher action is necessary.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_3_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_CLIENT-1-UPGRADE_COMPLETE ### Response: (Severity: 1), (Category: PLATFORM), (Description: The given FPD upgrade is complete.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-CHASSIS_IDPROM_READ ### Response: (Severity: 3), (Category: DRIVER), (Description: IOFPGA driver was not able to retrieve a valid chassis IDPROM image from backplane. This failure will prevent applications that requires a valid chassis serial number from operating correctly.), (Recommended Action: Perform RP fail over to see if the other RP has the same problem. If problem persist, try to power-cycle the chassis to recover from the failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_4_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_MGR-7-ERR_CLIENT_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: CCSQ Manager client Registration/Unregistration error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE6_CODE_ERR_HIGH_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE6_CODE_ERR_HIGH interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure OSPF as a PE-CE protocol in MPLS L3VPN? ### Response: To configure OSPF as a PE-CE protocol in MPLS L3VPN, use the 'vrf' command in OSPF configuration mode. router ospf 100 vrf MyVRF area 0 interface GigabitEthernet0/0/0/0 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-MANDATORY_OFF ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-DSC_CONN_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to connection failure to DSC for satellite boxes. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_FPOE_DB_UCORR_ECC_ERROR_LNK4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast FPOE uncorrectable ECC error on link 4), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-3-lsp_update_peer_absent ### Response: (Severity: 3), (Category: OS), (Description: Unable to update LSP due to absense of LSP), (Recommended Action: Check LSP name specified in EXEC CLI) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you deactivate a software package in Cisco IOS XR? ### Response: A software package can be deactivated in Cisco IOS XR using the 'install deactivate' command, which disables the package's features on the router without removing the package. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to disable RSVP on an interface in Cisco IOS XR? ### Response: To disable RSVP on an interface, use the 'no mpls traffic-eng interface' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#no mpls traffic-eng interface GigabitEthernet0/0/0/0 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_BDI_DEMC ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-LSPCKSUM ### Response: (Severity: 4), (Category: ROUTING), (Description: Bad L-# LSP LSP-ID checksum ACTUAL-CKSUM received on INTERFACE-NAME, length PDU-LENGTH should be EXPECTED-CKSUM, bad count CKSUM-ERROR-COUNT. This system received a level L-# LSP with a wrong checksum. If the IS-IS configuration option 'isis-ignore-cksum-errors' is set, the packet has been ignored. Otherwise it has been handled according to the specification.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_4_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power greater than or equal to the high Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cds_proxy-3-RWLOCK_DESTROY ### Response: (Severity: 3), (Category: OS), (Description: Failed to destroy read write lock.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-GEN_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-4-DEBUG_EVM_CREATE ### Response: (Severity: 4), (Category: OS), (Description: QNET process tried to create debug evm but encountered error specified The process may not be able to handle debug events), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_SYSDB_BAG_DECODE ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-3-ERR_PEER_NOT_ISOLATED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Peer RP/SC is not isolated after node crash. The crash node will be reset automatically), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-5-SC_PKDTUPLEFILE ### Response: (Severity: 5), (Category: SYSDB), (Description: An error occurred during a read operation from the instruction file.), (Recommended Action: Check that the file format is correct. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-SDK_POSIX_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is a message in FIB platform to indicate that engine layer identified an error while programming an object in SDK.), (Recommended Action: Please collect the console log, show tech-support cef platform. Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-3-ERR_ENABLE ### Response: (Severity: 3), (Category: FABRIC), (Description: The driver failed to enable/disable inter-process communication with fgid_server. This will prevent ucd/mcd messages to be exchanged between fgid_server and driver.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-7-ERR_MEM_ALLOC ### Response: (Severity: 7), (Category: FABRIC), (Description: FSDB has failed to allocate memory for its resources. This would affect proper functioning of fabric.), (Recommended Action: This indicates a low-memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFL_MGR_COMMON-3-OBFL_DEV_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: obfl_mgr process failed to access OBFL device. This could be because of hardware related failure.), (Recommended Action: Need to collect the logs related to obfl_mg from the node where this issue is reported.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_LOCAL_REG_READ ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected a local register read error.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL_SIP700-3-EDM_INIT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The CPU Control driver failed to initialize External Data Manager (EDM) processing. The effect is that the CPU Control driver show commands are not functional. This means that display information used by customers and Cisco support to monitor the CPU Control device may not be available. This does not impact normal CPU Control device operations. In particular, this failure would impact the 'show controllers CPUCtrl a9k-sip-700' commands. %s - description of the specific failure encountered %s - error detail, if appropriate), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers CPUCtrl ltrace location <>/<>/CPU0 command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers CPUCtrl ltrace location <>/<>/CPU0 output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information. If CPU Control display output is required then the cpu_ctrl process can be restarted on the LC in question using, process restart cpuctrl location <>/<>/CPU0 . This process restart may or may not result in successful EDM initialization depending upon the underlying problem. Note that it is unlikely that this failure would occur by itself. This failure is generally indicative of a larger LC-wide problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-7-ERR_EXIT ### Response: (Severity: 7), (Category: PLATFORM), (Description: An error occurred in ClkCtrl Driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTY-3-MEM ### Response: (Severity: 3), (Category: MGBL), (Description: The VTY DLL has failed to acquire the required amount of memory), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key components of the IOS XR Install Manager architecture? ### Response: The main components of the Install Manager architecture are\n- Install Manager (instmgr): Runs on each node, responsible for package management and installation\n- System Manager (sysmgr): Manages the startup and monitoring of processes\n- System Database (SysDB): Stores install-related states and information\n- Inventory Manager: Keeps track of cards in the system\n- Shelf Manager: Monitors and controls hardware on each card\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlma-3-IM_CONNECT_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The VLAN MA process failed to connect to the IM server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_AIS_DEMA ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FLOWTRAP-4-BAD_ACTOR_INTF_DETECTED ### Response: (Severity: 4), (Category: OS), (Description: The punt flow trap sampler detected an excessive flow on an interface. This could result in a denial of service to other interfaces. The interface will be placed in a 'penalty box' and policed at a much lower rate for a specified time period.), (Recommended Action: No action necessary. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-REP_COM_REMOVE_TRIGGER_FAILURE ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that install remove inactive all as part of the replace operation couldnt be triggered.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE_ERR_6_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE_ERR_6 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_1_XAUI_RDY_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: NPU-1 XAUI not ready on bridge instance-1.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-SW_COOKIE_UPDATE_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The IOS-XR install infrastructure has failed to update its software cookie on a particular node. This cookie is used to verify that software on different nodes in the system is in sync.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-EVENT_CONN_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_PLU-1-PLU_RESMON_OOR_RED ### Response: (Severity: 1), (Category: PLATFORM), (Description: PLU resmon on the node has detected that the number of routes has exceeded prescribed limits. Any further increase routes will lead to traffic loss.), (Recommended Action: Take immediate action to delete routes from the system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWRMON-1-SINGLE_FEED ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Single feed mode configuration changed, if enabled no warnings will be generated if one DC module feed is not connected or voltage is out of range'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_L2TP-6-INIT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the platform L2FIB L2TP component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_9_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-4-PACKAGES_RECORD_FILE_CHANGED ### Response: (Severity: 4), (Category: INFRA), (Description: The file that is used by the install infrastructure to record the active/committed packages for the duration of an atomic change/transaction has been altered since it was written by the install infrastructure, either by mistake or as a result of an attempt to falsify the active/committed packages information. This may cause the information in the active/committed packages lists to be inaccurate.), (Recommended Action: Ensure that only authorized people have access to the router. If the active packages file has been changed, apply or abort the atomic change to see accurate information about the active packages. If the committed packages file has been changed, commit or roll back the current transaction to see accurate information about the committed packages.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-3-SET_RLIMIT_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Failed to set resource limit. Dumper process will restartils.), (Recommended Action: Please restart the process dumper.If the issue persists then, Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. show memory) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR_DLL-6-PERFMON_ENABLED ### Response: (Severity: 6), (Category: PLATFORM), (Description: The user is attempting enable/disable the performance monitoring feature. But the feature is already enabled/disabled.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_0_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser bias less than or equal to the low laser bias alarm threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-INVALID_ROLE_STATE ### Response: (Severity: 3), (Category: LICENSE), (Description: From the last role event, we can only move to certain roles. The device has moved to a role which the Smart Agent cannot follow.), (Recommended Action: Please check the smart agent syslog file for more information. Please turn on the smart agent debug mode and retry again for additional information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PM-6-IFH_READ_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The Service Platform Manager encountered an provisioning info.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect 'show log location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NQC-3-PAK_OPERATION_FAIL ### Response: (Severity: 3), (Category: OS), (Description: The specified operation failed on the packet.), (Recommended Action: Collect the information specified in the required_info. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-6-PORT_STATE_CHANGE_ADMIN_DOWN ### Response: (Severity: 6), (Category: INFRA), (Description: Informational message indicating that the admin state of the specified port has changed to down.), (Recommended Action: This is an informational message and does not necessarily indicate a problem. This message is expected when the port's admin state is changed via CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-3-MODULE_UNAVAILABLE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Module was unavailable to be accessed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check the card is inserted properly if it is externally accessible. Capture 'show media' and 'show filesystem ' together with console log.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EEM-6-ACTION_SYSLOG_LOG_INFO ### Response: (Severity: 6), (Category: HA), (Description: The action_syslog call from tcl script.), (Recommended Action: Please verify command(s) mentioned in tcl script prior to error message are working fine (on router prompt). If issue is still seen then please provide command details which has resulted into this error condition to technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-ING_INV_LEN_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Invalid ingress NPH length detected on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-3-GEN_ERR ### Response: (Severity: 3), (Category: L2), (Description: An IPV4-specific software error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an MPLS label switch path in IOS XR? ### Response: To configure an MPLS label switch path (LSP), use the 'mpls traffic-eng' commands within router configuration mode. RP/0/RSP0/CPU0:router(config)#mpls traffic-eng RP/0/RSP0/CPU0:router(config-mpls-te)#interface GigabitEthernet0/0/0/1 RP/0/RSP0/CPU0:router(config-mpls-te-if)#autoroute announce <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-2-SHM_INIT ### Response: (Severity: 2), (Category: L2), (Description: L2fib shared memory initialization failed because server failed to map shared memory. If shared memory is not initialised, it can result in wastage of shared memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-7-VERBOSE_STR_HEX ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_MEM_ALLOC ### Response: (Severity: 4), (Category: L2), (Description: The process failed to allocate memory for the specified resource.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-MCAST_PAGE_ERR_3 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Multicast page error on bridge instance-3.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHDLCDLL-3-ERR_DEBUG_REGISTER ### Response: (Severity: 3), (Category: L2), (Description: There was an error registering the cHDLC Netio debug with the debug library. No debug will be available for the cHDLC Netio DLLs.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-3-FIELD_GROUP_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: OFA failed to create field-group on this NPU.), (Recommended Action: Verify your hw-module configuration. Otherwise, collect show-tech and contact cisco support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-6-LTRACE_INIT_FAIL ### Response: (Severity: 6), (Category: QOS), (Description: Ltrace initialization failed within EA. Ltraces may not be printed), (Recommended Action: Try restarting QoS EA process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_SOCKET-3-NOMEM ### Response: (Severity: 3), (Category: L2), (Description: The system is low on memory and not enough was available to complete the request), (Recommended Action: Check the box for processes with excessive memory If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-ISSUMGR_MILESTONE_ERR_RC ### Response: (Severity: 3), (Category: ROUTING), (Description: An external software error was returned form issu mgr.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The issu milestone update API for milestone start/met has returned error. This may be transient error, and the API will be retried. If repeated, please collect the output of the following commands: - show tech-support routing ospfv3 - show tech-support issu) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-2-MIDPLANE_DAT_FILE_PARSE_FAIL ### Response: (Severity: 2), (Category: FABRIC), (Description: FSDB server failed initialization with above reason.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAOC768-3-ASIC_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An ASIC error occurred in PLAOC768 ASIC which is reported here.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-TTY_DETAILS ### Response: (Severity: 3), (Category: MGBL), (Description: tty_details_from_device_file() failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-CPU_PROTOCOL_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter driver detected a protocol error from the CPU), (Recommended Action: The error message indicates illegal CPU bus handshake protocol, contact support if the error message persists after a few reloads of the card by either 'hw-module location <> reload' or OIR of the card. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different Inter-AS MPLS VPN implementation options? ### Response: The main Inter-AS MPLS VPN implementation options are\n- Option 1: Back-to-back VRF (virtual routing and forwarding) connections at the AS boundary routers\n- Option 2: EBGP redistribution of labeled VPN-IPv4 routes between the AS boundary routers\n- Option 2a: EBGP redistribution of VPN-IPv4 routes with next-hop-self\n- Option 2b: EBGP redistribution of VPN-IPv4 routes with redistribute connected\n- Option 2c: EBGP redistribution of VPN-IPv4 routes between loopbacks\n- Option 3: Multi-hop EBGP redistribution of labeled VPN-IPv4 routes between route reflectors\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-6-HA_INFO ### Response: (Severity: 6), (Category: ROUTING), (Description: Information related to HA events like NSR readiness.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-CARD_RELOAD_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that shelfmgr has failed to reload the specified node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-SCH_1_HANG_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Scheduler 1 Hang on bridge instance-0.), (Recommended Action: Please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_BOARD_PLD_VERSION ### Response: (Severity: 3), (Category: FABRIC), (Description: This indicates that the fabric board is running with PLD version that is not supported. Version lower than (0x1c) is not supported. Please upgrade to the latest PLD Version.), (Recommended Action: Shut down the plane associated to this fabric card, and upgrade the PLD Version of this board. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-ACL_COMPRESSION_NOT_SUPPORTED_MASK ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: ACL Compression is not supported on zero mask for prefix with 0.), (Recommended Action: Change related mask to be 255.255.255.255 for prefix with 0 or just any.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-MAIN_VSUPR_ALERT ### Response: (Severity: 4), (Category: DRIVER), (Description: Voltage supervisor on LC card reports alerts. No handling is required from the software side, except logging this message.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VI_REPL-7-EVENT ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: An unhandled error occured while waiting for an event.), (Recommended Action: The process will restart and attempt to recover from this problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls ldp discovery transport-address' command in IOS XR? ### Response: The 'mpls ldp discovery transport-address' command is used to specify the transport address to be used for LDP discovery messages. By default, LDP uses the router ID as the transport address. This command allows you to use a different address, such as a loopback interface address, which provides greater flexibility and stability. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-5-AUX ### Response: (Severity: 5), (Category: OS), (Description: The AUX login to a virtual service may allow the user access to system functions that may not have been tested or may interact with the system in unintended ways. Use with caution.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_FPGA-3-IMDR_ERR ### Response: (Severity: 3), (Category: L2), (Description: Plim datapath fpga driver imdr errors. Typically these errors indicate failure in system services during the imdr procedure.), (Recommended Action: Check whether process 'plaspa_server' is up and running. Check if the linecard reported any other errors and/or traffic loss was observed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-CONN_INIT ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when trying to connect to the respective component.When this issue happens, it will trigger an automatic restart of pifibm_server_lc.), (Recommended Action: Check the status of the respective component because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-6-WRITE_MAC_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Display dst mac address. %x- MAC address value.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-CPP_PKT_F3_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: IBS from CPP packet FIFO 3 single bit error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-ISM_PD_LIB_RELOAD_DATA ### Response: (Severity: 6), (Category: INSTALL), (Description: This message is seen during ISSU/iMDR if service processor on the linecard reloads and the corresponding CPU on the linecards must be reloaded as well.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-MGD_TIMER ### Response: (Severity: 4), (Category: L2), (Description: PTP encountered an unexpected error using the Managed Timer library. This is most likely to be due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the PTP MA process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option explicit name feature? ### Response: The MPLS TE path-option explicit name feature allows an MPLS TE tunnel to use a named explicit path configured separately from the tunnel. A named explicit path is a reusable path definition that can be applied to multiple tunnels. It provides a way to define explicit paths independently of tunnel configurations. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-3-TRACE_INIT ### Response: (Severity: 3), (Category: MGMT), (Description: This comes when trace infra initialization fails due to some infra issue, the program will re-strat to connect the same), (Recommended Action: The program restarts once it fails to connect to event manager infra, would be fine once that infra is up) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_4_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-5-ASIC_ERROR_HARD_RESET_START ### Response: (Severity: 5), (Category: PLATFORM), (Description: An ASIC error has occured and need to hard reset, this marks the beginning of it.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-FINDDATA ### Response: (Severity: 7), (Category: MGBL), (Description: An error occurred invoking an MDA function. The details are in the error string), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GDOI-7-CONFIG_WRITE ### Response: (Severity: 7), (Category: OS), (Description: A MB command is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_9_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_9 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FMGR-3-TCAM_MGR_QOSID_ALLOC_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Request to TCAM Manager for allocating a QOS Policy ID for a policy attached to an interface failed. The most likely cause of this error is not enough ACL IDs remaining in TCAM manager. QOS policy on this interface will not take effect since TCAM entries are not programmed.), (Recommended Action: The QoS policy on this interface must be removed to free up other allocated hardware resources. QOS IDs may become available if policies are removed from other interfaces. In global configuration mode go to interface and 'no service-policy input | output ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_400G_POD-2-TX_CH_FAULT ### Response: (Severity: 2), (Category: FABRIC), (Description: The Tx POD detects a fault on a channel. The channel might not be functioning properly, and can cause cell drops, or corruption in the downstream.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SUB_UTIL-5-SESSION_THROTTLE ### Response: (Severity: 5), (Category: SUBSCRIBER), (Description: Subcriber Session Flow control is enabled or disabled. Because Subcriber Infrastructure become is ready or not ready. i.e, system recovered from or reached to critical state or BNG infra strucute process is restarted, hence new subscriber sessions creation is enabled or disabled.), (Recommended Action: Check system heap/shmwin status along with state of subscriber infrastructure processes. If this message is seen due to a BNG infrastructure related process then the issue will be resolved automatically after the restarted process is completed its initialization. Else please collect the following logs when this ios message is seen. 'show subscriber infra readiness trace process ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-SYSDB_BIND ### Response: (Severity: 3), (Category: OS), (Description: Unable to bind to sysdb.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support sysdb command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support sysdb output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-FGID_ISSU_REG_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while ISSU registration. The error condition can occur while: (1) register ISSU notification event (2) trying to retrieve ISSU state), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-4-MAX_PACKET_SIZE_RANGE ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The maximum packet size requested on an interface is outside its operational range. This may result in traffic loss on the interface.), (Recommended Action: Check the MTU configuration on the interface and its subinterfaces, it may be necessary to raise or lower any configured values to achieve MTU values within the supported range. If this does not help Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-MLACP_CONNECT_FAILED ### Response: (Severity: 5), (Category: L2), (Description: It was not possible to connect to the specific to a peer device in the specified ICCP Group. mLACP will not be running over the specified ICCP Group.), (Recommended Action: If the reason message indicates that the failure is because the application is not in the ICCP Group, ensure that mLACP is configured for the ICCP Group on a peer router. Otherwise, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-6-PA_UPDATE ### Response: (Severity: 6), (Category: OS), (Description: Update from PA failed.), (Recommended Action: Restarting lpts_pa may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-VIRT_INST_STATE ### Response: (Severity: 3), (Category: OS), (Description: The named virtual service has failed. It is no longer running either because the guest OS has failed, the guest OS has shut down the machine or the emulator has failed.), (Recommended Action: An attempt at restarting the virtual service can be made from the IOS configuration by doing a no activate/activate. For debugging collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_SYSDB_STRING_CODING ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed to encode or decode a string using the SysDB encoding. Aa result IS-IS will not be able to complete the operation it was performing when it encountered the error. The message describes the string which was being encoded or decoded and this should indicate the nature of the operation which was being performed.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-4-MAPPING_ERROR ### Response: (Severity: 4), (Category: MGBL), (Description: The RS232 DLL was unable map from a TTY ID to a UART port), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_11_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-3-SAC0_ECTW_RDATA_TO ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-7-BUFFER_GARBAGE ### Response: (Severity: 7), (Category: OS), (Description: A buffer has garbage bytes at the end.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPP_PKT_F2_MBE ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPP packet FIFO 2 multiple bits error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-GET_PROC_TIDSTATUS_FAILED ### Response: (Severity: 6), (Category: OS), (Description: Dumper collects all the process related data by using system call devctl. If a devctl fails, then the core file will be incomplete. This will not impact the system.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-5-MULTIFLOW ### Response: (Severity: 5), (Category: ROUTING), (Description: Error in the flow control algorithm in EIGRP. EIGRP may recover itself temporarily by doing the necessary error handling.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4MC_STATIC-7-ERR_EVENT_INIT ### Response: (Severity: 7), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-3-PCIE_CORE_ERROR_OVERRUN ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP_NSR-3-INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: An software error occurred while initializing the TCP SSO functionality. If this occurred during process startup, then the process may be restarted.), (Recommended Action: The process may attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-ERR_REDIST_INFO_CLEAR ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occured when trying to clear redist information for a client.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-IDB_PRESENT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp global-interface command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp global-interface output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp interface command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp interface output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace im error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace im error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR node protection desired feature? ### Response: The MPLS TE FRR node protection desired feature allows link protection to be used even when node protection is configured on a tunnel. It provides a way to prefer node protection but use link protection as a fallback. The tunnel is protected if possible, but a best-effort approach is used otherwise. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of using Modular Quality of Service CLI (MQC) in Cisco IOS XR? ### Response: MQC in Cisco IOS XR is used for creating and applying traffic policies, which include classifying, marking, and managing traffic flows to ensure bandwidth allocation and prioritization of critical services. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-3-ERR_CONN ### Response: (Severity: 3), (Category: L2), (Description: An error occurred on one of the event connections managed by CDP which CDP could not recover automatically.), (Recommended Action: Try restarting CDP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REBOOT_LIB-4-CAUSE_INVALID ### Response: (Severity: 4), (Category: INFRA), (Description: Warning message that the reboot cause is out of range), (Recommended Action: Collect show log and traceback details. The process emitting this error message may need to analyse why saving invalid cause code.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TSEC-6-DRIVER_INFO_1REG ### Response: (Severity: 6), (Category: PLATFORM), (Description: The particular operation mentioned in the message gave an informative message with one register value. This is not a failure.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_ETHER-4-SPA_WARN_RX_PWR ### Response: (Severity: 4), (Category: L2), (Description: SFP hit/recovered RX Low power warning.), (Recommended Action: No action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-4-HBLOSS_NOTIFY_HBAGENT_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: The particular operation mentioned in the message has failed. As a result, when there is a flood reddrv hbloss from all nodes, a failover will not happen.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between IOS XR bootable files and PIEs? ### Response: Bootable files (with .vm extension) are used to boot an IOS XR router from ROM Monitor (ROMMON) mode. They contain the minimal set of packages required for booting the router. In contrast, PIEs are used to add features or upgrade an already running IOS XR image. They can be added or removed without rebooting the router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL-3-CURRENT_MAXIMUM_LOW ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: New current max is lower than the current tunnel count.), (Recommended Action: Use a current maximum value which is lower than the current tunnel count.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_DIR-3-NTFN_CAPI_SERVER_INIT_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: ISSU Director encountered an error and was unable to set-up the ISSU Event Notification CAPI service.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-MAC_0_TX_FIFO_OFLOW_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: MAC on NPU-0 had transmit fifo overflow on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_ST3E ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from ST3. Traceable condition indicates that the synchronization message quality level is changed to or from ST3E from a lower level of synchronization. SSM-ST3E is a Generation 2 SSM and is used for Generation 1.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFD_HELPER-7-DEBUG ### Response: (Severity: 7), (Category: MGBL), (Description: General debugging information for development and general diagnosis.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PM-6-L2TRANSPORT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Generic info messages pertaining to service PM.), (Recommended Action: No action is required for this message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-WDSYSMON_REGISTER_FAILURE ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-IN_MEM_ERROR_LNK1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected an input memory error on link 1), (Recommended Action: This alarm is transient and should auto-clear when error condition is resolved. If the alarm doesn't clear, then please reload the card using command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an L2VPN EVPN instance? ### Response: To configure an L2VPN EVPN instance, use the 'evpn' command within the BGP configuration mode. router bgp 65000 address-family l2vpn evpn neighbor 10.1.1.2 activate <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-2-INIT_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: There was an error during PCIe server initialization phase. The error message has detailed information.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-6-DEVICE_FORMAT ### Response: (Severity: 6), (Category: INSTALL), (Description: Either due to a format directive at turboboot time, or because the indicated device is not available, insthelper will now try to (re)format the device to make it available.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ASIC-3-PIO_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The PIO operation on PLIM ASIC failed due to a hardware or software error. %s - description of the error. %s - description of the operation. %d - PLIM ASIC instance number %d - port number. %08x_%08x - address of the operation %s - description of the error details.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CRS_PAK_BUFHDR-3-PACKET_LENGTH_EXCEED_FABRIC_LIMIT ### Response: (Severity: 3), (Category: L2), (Description: The client is requesting to set packet length to a value that exceeds CRS fabric limit. Such a packet will be dropped. This may be caused by an internal software error or by the router's receiving of malformed packets.), (Recommended Action: If the error messages persist, please collect the required logs and report to it CISCO TAC. Also notice if the error message is transient or persistent, before you report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPA_1P_OC192-3-ERR ### Response: (Severity: 3), (Category: L2), (Description: fails to init debug event manager fails to provide its service), (Recommended Action: 'show logging' to confirm there is any error from event mgr) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-4-PAK_NETIO_UINT8_GET ### Response: (Severity: 4), (Category: OS), (Description: Failed to identify version of ip packet.), (Recommended Action: This is not a critical error and it may get recovered if the netio process is restarted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-SYSDB_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured while communicating with sysdb.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging processes msdp command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging processes msdp output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace events command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace events output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace cache command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace cache output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are some of the tasks handled by Install Manager in IOS XR? ### Response: Some of the tasks handled by Install Manager in IOS XR include: fresh installation of an IOS XR image, upgrade or downgrade of an IOS XR release, addition and activation of PIEs and SMUs, removal of inactive PIEs from boot device, and rollback of installed software to the previously active version. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlma-4-RECOVERY_FAILED_BATCH ### Response: (Severity: 4), (Category: L2), (Description: The VLAN MA failed to resynchronize its configuration with another component in the system after an earlier failure, or process restart.), (Recommended Action: After gathering the information specified, it may help to restart the VLAN MA process on the affected node, with proc restart vlan_ma location [location]. If this restart completes without the message appearing again, the problem has been resolved. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-RECOMMENDED_PKG_OP_COUNT_EXCEEDED ### Response: (Severity: 6), (Category: INFRA), (Description: A large number of packaging operations have taken place without an install commit operation. If this limit is exceeded, install reporting, in particular via show install log and show install history commands may become slow. It is recommended to complete the transaction by performing install apply and then install commit.), (Recommended Action: Execute the install apply and then install commit commands once the current packaging operation has completed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_11_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-EVENT_CONN_OPEN ### Response: (Severity: 7), (Category: INSTALL), (Description: The library failed to open a connection for registering for install notifications.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_HFR-7-ERR_GEN ### Response: (Severity: 7), (Category: ROUTING), (Description: MFWD-HFR library encountered error during setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_MPLS-3-ERR_INFO ### Response: (Severity: 3), (Category: L2), (Description: Platform MPLS FIB, error information), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace [common|mpls] all loc <>). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-7-ERR_INTERNAL ### Response: (Severity: 7), (Category: OS), (Description: An internal system error occurred.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-AAA_INVALID_TASKID_SIZE ### Response: (Severity: 3), (Category: MGBL), (Description: 'Found invalid/corrupted AAA data'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-DEVICE_EXIT_FAILED ### Response: (Severity: 4), (Category: MEDIA), (Description: The media storage card specified failed to exit properly due to the specified reason. The returned error code is specified.), (Recommended Action: Format media device manually if device fails to come up. If it still fails, replace media device.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-SEQ_STATE_POST_OP_FAILED ### Response: (Severity: 3), (Category: FABRIC), (Description: Ingressq driver state machine encountered a failure in initializing the device above threshold number of times. Driver will continue to initialize the device.), (Recommended Action: No user action is required. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-REGISTER_INSTMGR ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to register for notification from install mgr failed. The error is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX8508-3-EXIT_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The message can be displayed whenever there is a driver initialization error.), (Recommended Action: The driver process will re-start and complete initialization of the switch device. However, if this message is seen for more than 5 times than please reload the card using -hw-module location <> reload and check if the message still occurs in subsequent reload.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-1-ERR_LOCALBUS_FAULT ### Response: (Severity: 1), (Category: FABRIC), (Description: Fabric FPGA detects the specified local bus fault.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_EA-4-ERR_EVC_ERROR ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: After detecting an error with the IMP connection, PPPoE EA failed to reset that connection. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_SUBDB_IF ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the SubDB service. The error message describes what operation has failed and why it failed. The most likely reason for this is a connection problem with the SubDB server, but the error could also be caused by low memory resources or programming error.), (Recommended Action: Consider restarting the PPP MA process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_CLIENT-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A failure has occured in the FPD Client, there is a corresponding error code and error string.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-0-CARD_RESET_REQ ### Response: (Severity: 0), (Category: PLATFORM), (Description: Platform Fault Manager Node is performing a card reset based on recovery action defined in the Application Fault Condition Database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-3-ALARM_CLEARED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Alarm cleared received from CBC, condition has alleviated.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-XAUI_0_FRAG_ERR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: XAUI interface to NPU-0 reported fragmentation error on TX side on bridge instance - 1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-4-MEM_STATE_CRITICAL ### Response: (Severity: 4), (Category: ROUTING), (Description: A critical memory state notification was received. The process has exceeded the rlimit and will attempt to increase it dynamically.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_XRV9K-3-ERR_AIB_INIT ### Response: (Severity: 3), (Category: L2), (Description: BFD PLAT was unable to setup the cwconnection to AIB for processing adjcency changes events. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will reload the MSC.), (Recommended Action: Collect all the event logs and the output of following command executed from the CLI : 'show process bfd_agent location ' 'show process block location ' and 'show bfd platform trace error location ' 'show tech-support routing bfd') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_0_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Tx power greater than or equal to the high Tx power alarm threshold. The QSFP+ is the pluggable optics on the line cards. The Tx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Replace the QSFP+ with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS traffic engineering fast reroute feature? ### Response: The MPLS traffic engineering fast reroute (FRR) feature provides link and node protection for MPLS TE tunnels. It enables fast traffic recovery upon link or node failure using pre-signaled backup tunnels that bypass the protected resource. It is enabled on a per-tunnel basis with the tunnel mpls traffic-eng fast-reroute command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-2-INIT_FAILURE ### Response: (Severity: 2), (Category: OS), (Description: PCE Initialization failed. The message displays the failed operation and the error code. Due to this failure, the PCE server is not capable of providing path computation service.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: tunnel_ea-3-IMP_INIT_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This is typically an internal error in the software. The software failed to initialize a connection to another process in the card where the error is seen.), (Recommended Action: If there is a problem, it might be cleared by restarting tunnel_ea. If the problem persists, copy the error message as it appears on the console and any noticeable side effects. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-3-REVERT_ECHO_SOURCE_ADDRESS_SUCCESS ### Response: (Severity: 3), (Category: L2), (Description: Revert echo source and construct echo packet hdr for BFD session successfully.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-4-DUP_REMOVE_ERR ### Response: (Severity: 4), (Category: SERVICES), (Description: The given attachment configuration, which was previously invalid due to duplicate attachments being configured on different interfaces, is now valid as the duplicate attachment configuration has been removed, but an error has occurred reimplementing the attachment. The error string given should give more details on the error that has occurred.), (Recommended Action: For non-resource errors, removing and adding back the configuration that prompted the message may remove the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the error is a resource error this will be indicated in the error description given. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-THREAD_MUTEX_LOCK ### Response: (Severity: 7), (Category: OS), (Description: A internal mutex operation has failed. This is a bug.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_1_CONST_BP_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: NPU-1 is constantly backpressuring bridge instance-0.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEPKI-6-CERT_EXPIRING ### Response: (Severity: 6), (Category: SECURITY), (Description: Cerficate is expiring within the specified time, in a week.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_PARSE_FILE ### Response: (Severity: 3), (Category: FABRIC), (Description: A file describing switch fabric components has errors. Some fabric components cannot be brought into service.), (Recommended Action: A failed or incomplete software upgrade could cause this error. It could also be caused by corruption of an existing definition file. Ensure that the definition file is not damaged. If the problem persists, re-install the fabric control software.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-2-CONN_ERR ### Response: (Severity: 2), (Category: FABRIC), (Description: This is to indicate that the process has failed to connect or send message to the fabric management process to get information on Max. groups per rack.), (Recommended Action: Get the output from the following commands: 'admin sh tech fabric fast-snap') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_PM-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform Manager encountered a runtime error. A text reason and an error number are supplied to describe the error. Runtime errors usually concern individual interfaces. PM continues. Applications often retry the same operation to recover.), (Recommended Action: If error persists, please collect output of 'show log location ', 'show controller pm trace error location ' 'show controller pm trace creation location ' and 'show controllers pm location '.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-4-WRN ### Response: (Severity: 4), (Category: OS), (Description: A WARNING level message was emitted by QNET.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-TRACE_BACK_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Could not figure out trace back), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCAM_MGR-3-INTERNAL_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An internal error occurred in TCAM Manager which involves exiting the process. After the TCAM Manager process restarts, the error should have been cleared.), (Recommended Action: Collect the configuration, syslog and coredump file. Attach them to the ddts. After the process restarts automatically, the error should have been cleared and no user action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-4-CLIENT_API_ABUSE ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: An IM client has used the IM API in an unexpected way, usually implying a bug in the client code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-REDIST_FAILED ### Response: (Severity: 4), (Category: ROUTING), (Description: An error occurred while OSPF was setting up redistribution for the named protocol. The redistribution will not take place.), (Recommended Action: This may be due to lack of memory, or due to a RIB failure, or to an internal OSPF problem. It may help to restart the OSPF process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show running-config - show configuration failed - show configuration history last 5 - show commit changes - show logging - show ospf trace all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC12 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAW_LIB-3-FILE_OPEN_FAILED ### Response: (Severity: 3), (Category: MEDIA), (Description: File open failed. Reboot history index got corrupted. When recovering the reboot history index, file open operation failed. Please verify the reason why it is failed.), (Recommended Action: Erase the entire reboot history information is only option. Please execute 'erase nvram-raw: loc ' command to erase the reboot info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XBAR_CLIENT-3-GEN_ERR_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates an error condition in client library api while communicating with the server process. It may be caused due to invalid api arguments by client process or a transient condition while the server process is initializing the ASIC), (Recommended Action: This message may indicate a transient condition while the card is booting up. Please check if the error message is seen continuously even after the card has reached IOS-XR RUN state. And if so, then try to power cycle the card. If the message is seen in every power cycle after the card is in IOS XR RUN state then please contact tech-support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_LIB-4-INTF_DB_INCONSISTENT ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: An inconsistency has been found in the adjacency manager interface database. The adjacency manager will automatically recover from this; nevertheless it may indicate a software error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-7-HANDLE_PARK_MUX ### Response: (Severity: 7), (Category: PLATFORM), (Description: This debug message indicates the start/end of I2C bus parking. Since shelfmgr power-cycles this card immediately after this parking, this message might not show up on the RP console. But if there is any delay during msg_chan_connect or I2C bus park steps, then this message will help to findout which step caused the delay.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cpposlib-3-INIT_NOTIFY ### Response: (Severity: 3), (Category: L2), (Description: A function failed to initialize.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-CPP_PKT_DIP4_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: IBS from CPP packet SPI error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-6-FAILED_BOOT_DURING_INSTALL_RESET ### Response: (Severity: 6), (Category: INSTALL), (Description: On bootup the node attempted to contact the Install Director on the dSC. The Install Director was contacted and informed the node that it could not boot because an installation was in progress. The Install Director then became unavailable. Therefore, to ensure that this node boots from an up to date Install Director it will reboot itself. This message will only be seen on an RP.), (Recommended Action: The node will reboot to obtain the correct software. If the node ends in ROMMON (as the config-register was not set to auto-boot) then it is recommended to simply set the config-register to autoboot and reset to boot the correct software. unset BOOT sync confreg 0x2 reset) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-2-FATAL ### Response: (Severity: 2), (Category: MGBL), (Description: The TTY Server has encountered a fatal error and must restart in order to continue operation.), (Recommended Action: Check to ensure that the TTY Server has restarted. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA_TP-3-ETMM_ATI_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Internal error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TAMSVCS-3-TPM_NO_SUDI ### Response: (Severity: 3), (Category: SECURITY), (Description: TPM on this board is not programmed with SUDI. Starting software based secure storage.), (Recommended Action: This is an informational message that TPM/ACT2 on this card is not programmed with SUDI. Hence Software based Secure Storage will be activated on this card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-6-PRIO_INFO ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: 'Priority Info of event thread.' 'Handling spoof events.'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-HARD_RESET_START ### Response: (Severity: 4), (Category: PLATFORM), (Description: An internal network processor error has occurred. A hard reset is performed to recover from the specified error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-ERR_ISSU_QUIESCE ### Response: (Severity: 5), (Category: L2), (Description: A notification from the ISSU version 1 bundle process could not be sent to the corresponding version 2 process.), (Recommended Action: There is no action required to resolve this issue. This failure will not prevent successful completion of the ISSU operation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-6-BACKUP_CONNECTION_UP ### Response: (Severity: 6), (Category: HA), (Description: RMF has determined that the connection to the backup process groups location has been succesfully completed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNVGEN-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: MGBL), (Description: 'The system has run out of memory'), (Recommended Action: Collect the following logs and contact your technical support representative for assistance. a) show memory summary location b) 'show process nvgen_server' and get JID of this process c) show memory heap dllname If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GT_I2C-3-BACKPLANE ### Response: (Severity: 3), (Category: PLATFORM), (Description: As shown in the message.), (Recommended Action: None. Device was power-cycled to recover from the hang. If the error occurs even after power cycle, Please collect required_info log/trace and contact Cisco technical support representative with required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_AGENT-6-FPGA_GOLDEN_IMAGE_BOOT ### Response: (Severity: 6), (Category: DRIVER), (Description: The FPGA is booted with golden iamge on the indicated card. The output of 'show hw-module fpd' will show the affected images with BACK IMG state. This can happens when Primary image is corrupted, so it so it fallback to load the golden image set to recover from the failure.), (Recommended Action: Although the system will continue to run, the golden image set might be of older version and it might have known issues that have been fixed on latest version. So it is critical to address the problem as soon as possible. The output of 'show hw-module location fpd' will identify the image with the problem with NEED UPGD state and it will have missing Programmed version. To correct the problem, use the 'upgrade hw-module location fpd ' command to re-program the FPD image and power-cycle the affected card for FPGA to load with the upgraded image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OC768_FRAMER_ASIC-7-DEBUG_MSG ### Response: (Severity: 7), (Category: L2), (Description: This is a debug message in OC768 Framer ASIC driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_TCAM_ODS_INVALIDATE ### Response: (Severity: 3), (Category: OS), (Description: TCAM ods invalidate encountered FATAL ERROR.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GDOI-2-PARSE_MEMORY_ERROR ### Response: (Severity: 2), (Category: OS), (Description: No memory left to parse show output data), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-MAC_0_TX_FIFO_OFLOW_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: MAC on NPU-0 had transmit fifo overflow on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DWDM-4-PRBS_WARN ### Response: (Severity: 4), (Category: L2), (Description: PRBS test running in Maintenance mode and g709 must be enable, user has been restricted for enabling the PRBS test without meeting the requirement. But after enabling the PRBS test user can change the admin-state or G709 state, this can impact the PRBS test results.), (Recommended Action: Not change the admin-state and g709 state when PRBS test is running, or first stop the PRBS test then change the admin-state or g709 state, if user don't want to run PRBS test more.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-3-NODE_INT_SLOW_REP_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform Fault Manager Node encountered an error due to internal software issue and is able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-BFM_REGISTER_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_FADB_MAIN-3-RESPAWN_COUNT_GET_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB FADB encountered an error while attempting to attach sync event handler for process fsdb_fadb), (Recommended Action: Search the event logs for events/errors related to the failure reason. Utility to get respawn count is part of overall system. If there are failures here then other processes may also exhibit similar problems. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFEA_IPV4_EA-5-DEBUG ### Response: (Severity: 5), (Category: PLATFORM), (Description: AFEA IPV4-EA, Debug information), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_UNKCMD ### Response: (Severity: 4), (Category: SYSDB), (Description: The first token in a command string was not a recognised Sysdbcon command.), (Recommended Action: Check the list of available commands and retry. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-7-CERRNO_REG ### Response: (Severity: 7), (Category: SYSDB), (Description: The client library has failed to register SysDB's error code (cerrno) definitions.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_3_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-ERR_PROC_READY ### Response: (Severity: 3), (Category: ROUTING), (Description: The process was unable to signal process ready to the IOS-XR infrastructure.), (Recommended Action: Restart of EIGRP might solve the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MARVEL-3-EVENT_MGR_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Generic failure of any event manager API.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-2-HW_INIT_ERR ### Response: (Severity: 2), (Category: L2), (Description: The PLIM process failed to spawn due to failure in the PLIM hardware initialization process. The PLIM process is the driver for all PLIM hardware devices. %s - indicates the reason for the failure.), (Recommended Action: Check if the linecard reported any other errors during the boot process as this error might be associated with larger system issues. The error is most likely due to a hardware failure on the PLIM or MSC. Diagnostics should be executed on the PLIM and MSC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSI_AGENT-3-CONSISTENCY_CHECK_LTBL ### Response: (Severity: 3), (Category: OS), (Description: A software bug when an internal data consistency check failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_PFILTER_EA-3-INIT ### Response: (Severity: 3), (Category: L2), (Description: Initialization of cpp_pfilter_ea process has failed due to one of the following reasons: 1) Failed to initialize event manager. This would prevent process from receiving events. 2) Failed to register with debug. This would prevent process from logging debug messages. 3) Failed to initialize connection with pal_pfilter_ea service. 4) Failed to initialize connection with cpp_sp_svr (Feature Manager Service). 5) Failed to initialize connection with UIDB Manager Service.), (Recommended Action: System Manager process(sysmgr) will retry to start the cpp_pfilter_ea. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_INFRA-3-EVM_CREATE_FAILURE ### Response: (Severity: 3), (Category: INSTALL), (Description: A failure occurred attempting to create an Event Manager. The relevant process will restart and attempt to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-RTC_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Network Processor has detected an RTC error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-PROCESS_NAME_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Dumper failed to fetch process name. using pid instead. No impact.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG_HIST_UPDATE-3-SYSDB_BIND_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: Internal error), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSD_ENC-3-PREPARE_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Prepare phase for encryption operation failed has failed. If location all was specified for the operation, none of the cards will reload and the operation is considered a failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-3-MPA_INIT_VIC_START_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Unable to initialize the MPA due to failure in starting internal software process (vic).), (Recommended Action: Pls collect the output of the CLI 'show tech-support ethernet interfaces'. Please try to recover by doing the process restart of the process that generated the error. If the issue persists, contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-EVQ_ENQUEUE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occured while enqueueing the specified object on the specified queue.), (Recommended Action: This failure is most probably due to limited memory. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-3-SYSTEM_ERROR ### Response: (Severity: 3), (Category: IP), (Description: 'There was an error during invocation of a system call'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-STATE_UPDATE_DROPPED ### Response: (Severity: 3), (Category: L2), (Description: There were insufficient system resources to provide the CFM Protocol Manager with interface state updates. The state update notifications will not be delivered, and the interface states in Continuity Check Messages will be incorrect for the affected interfaces. Other CFM functionality is unaffected.), (Recommended Action: Wait until any situation which is putting stress on system resources is resolved, and then issue the 'process restart cfmd' command to resynchronize the Interface states within CFM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SECY_DRIVER-6-KAT_PASS ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-4-CONFIG_REMOVAL_FAILED ### Response: (Severity: 4), (Category: L2), (Description: A loopback session or sessions could not be stopped after Ethernet Loopback configuration was removed. The configuration has been removed but loopback sessions are still running.), (Recommended Action: Session removal attempts will continue to be attempted at 5 second intervals. If these removals eventually succeed no action is required. If the removals do not succed, the user may either wait for the loopback session to expire naturally at the end of its duration or restart the edpl_ma process using the following command: - process restart edpl_ma To stop the session manually, use the following command: - ethernet loopback stop local interface id If the error message indicates an error relating to interface manager, check the output of 'show proc blocked' and the health of the ifmgr process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is Outbound Route Filtering (ORF) in BGP? ### Response: ORF allows a BGP router to send its inbound prefix filters to a neighbor so that filtering can be done on the sending side. This conserves resources on the receiving router. It requires the ORF capability to be negotiated between neighbors. It is enabled with the neighbor capability orf prefix-list command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to enable OSPF on an interface? ### Response: To enable OSPF on an interface and specify the area, use the 'ospf area' command in interface configuration mode. RP/0/RP0/CPU0:router(config)#router ospf 100 RP/0/RP0/CPU0:router(config-ospf)#area 0 RP/0/RP0/CPU0:router(config-ospf-ar)#interface GigabitEthernet0/0/0/0 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-4-FAIL_TO_ELECT_MASTER ### Response: (Severity: 4), (Category: FABRIC), (Description: All the asics of the LCs in the system has been tried for master election but failed. Time sync is not attained in the system), (Recommended Action: Reload the system) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_VPLS-3-INIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the platform VPLS process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_14_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-IO_INITSYNC_SESSION_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A problem occurred in TCP init sync.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-PLATFORM_NODENAME ### Response: (Severity: 3), (Category: HA), (Description: An internal error was detected when trying to get local node name through platform library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-3-HIGH_VOLTAGE_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected an SFP voltage greater than or equal to the high voltage warning threshold. The SFP is the pluggable optics on the line cards. The voltage threshold values are read from the SFP.), (Recommended Action: Verify that the device is properly inserted. Check the 'show environment voltages'. If the system voltage is normal then replace the optics with working one (if any). If the system voltage is not normal, then make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure BGP to use a 4-byte autonomous system number in IOS XR? ### Response: To configure BGP with a 4-byte AS number in IOS XR, you specify the AS number in the 'asdot' notation within the BGP configuration. router bgp 1.10 commit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_6_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-3-DB_PTR_CORRUPT ### Response: (Severity: 3), (Category: L2), (Description: An internal inconsistency was identified while performing some operation on the database. The process will attempt to recover a consistent state, and should be able to continue operating. It is possible that some parts of the dataplane may become out of sync.), (Recommended Action: If additional problems are observed then restarting the process may help to restore the system to a consistent state. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XRV9K_FIB-3-DPA_DOWN ### Response: (Severity: 3), (Category: PLATFORM), (Description: The specified error happened during handling of data processing agent going down event.), (Recommended Action: show log show process blocked location <> show process fib_mgr location <> show process dpc_rm_svr location <> show controller dpc rm trace init location <> show controller dpc rm trace error location <> show controller dpc rm trace event location <> show controller dpc rm trace internal location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_FAN_RPM_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: The CPT 50 Panel Fan Unit RPM threshold crossing (SAT_FAN_RPM_ALARM) alarm is raised when the fan RPM crosses minimum/maximum threshold.), (Recommended Action: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-EVM_EVENT_BLOCK ### Response: (Severity: 3), (Category: SNMP), (Description: SNMP receives messages from an event manager. While trying to retrieve a message, an error occured, preventing successful receipt of the message.), (Recommended Action: Check 'show context' command to see if any crash happened . If there is a crash, you may need to collect 'show process blocked' and 'run attach_process -p ' output. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_6_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ZERO_COST_LINK ### Response: (Severity: 4), (Category: ROUTING), (Description: The specified LSP contains a link advertisement with an invalid metric of 0. Zero cost links have the potential to break the SPF algorithm and are not permitted by the IS-IS specification (ISO 10589 version 2) and so the IOS-XR router will ignore the link in any subsequent route calculations. As a result traffic which should be routed via the affected routers may be dropped or enter a routing loop.), (Recommended Action: Identify the source of the offending packet and correct it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-4-DROPPED_MSG ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: A message received from the Interface Manager on a different node has been dropped. This is due to incompatible versions of the software communicating with each other and will result in interfaces not working correctly.), (Recommended Action: Verify that all nodes are using consistent image versions. If performing an upgrade this message will stop appearing once all nodes are consistent. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_HEAP-7-MUNMAP ### Response: (Severity: 7), (Category: HA), (Description: When attempting to free memory that is no longer in use, the CDM library received an error from the kernel.), (Recommended Action: Collect system log information and forward to technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-FIA2NPU_1_PKT_MINLEN_ERR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet minimum length error on FIA to NPU-1 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-0-PCIE_ACCESS_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: 'Unable to access device through PCIE'), (Recommended Action: Gather the data listed in 'required_info'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-3-ACK_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The system has encountered an error while refreshing SFP port.), (Recommended Action: Replace with a Cisco supported SFP If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-WDSYSMON_REGISTER_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-2-INVALID_MSG ### Response: (Severity: 2), (Category: ROUTING), (Description: FIB internally manages its activity using 'events'. An error occurred while processing events. The process will attempt to recovery by restarting. If the restart count is excessive then the node may reload. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-5-CLOCK_INTERFACE_PORT_0_TX_DISABLE ### Response: (Severity: 5), (Category: PLATFORM), (Description: On the standby RSP, BITS outputs are disabled. This prevents the sync 0 transmitters on RSP0 and RSP1 from interfering with one another when a Y-cable is installed.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-2-SEARCH_CLUSTER_PARITY ### Response: (Severity: 2), (Category: PLATFORM), (Description: A parity error interrupt), (Recommended Action: This error can be corrected by reloading the LC using the command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-USER_AUTHEN_REJECTED ### Response: (Severity: 3), (Category: SECURITY), (Description: Processing of phase 1.5 (xauth) with peer failed.), (Recommended Action: 'Make sure the password delivered is indeed matching the client, otherwise contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. with the exact log message received') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DCL_LIB-4-CERR_REGISTER ### Response: (Severity: 4), (Category: HA), (Description: Error string registration failed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPB_I2C-7-BUS_HANG ### Response: (Severity: 7), (Category: PLATFORM), (Description: An I2C bus hang has been detected. Recovery is automatically attempted. Should the recovery be successful, a BUS_UNHANG_SUCCESS message is issued; otherwise, an UNRECOVERABLE_BUS_HANG is issued.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEMLOG-3-ERRCHECK ### Response: (Severity: 3), (Category: OS), (Description: An unexpected value was found in the error check.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-5-SECURITY_MAC_SECURE_VIOLATION_PBB ### Response: (Severity: 5), (Category: L2), (Description: The MAC secure in the Virtual Instance Port has detected violated packet. This might be a security attack. A relearn attempt had been made on the Virtual Instance Port for a MAC address which had been already learned by another secure port. One of following action might be configured and will be taken on this Virtual Instance Port: - Restrict: drop the packet and disable the learn attempt - None: forward the packet and allow the MAC to be relearned - Shutdown: shutdown the port on which the learn attempt was made If no action has been configured, the restrict action will be taken by default and packet has been dropped.), (Recommended Action: Fix the root cause of the mac security action and use l2vpn clear command to bring back this port; ( clear l2vpn bridge-domain ).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Embedded Packet Capture (EPC) feature in Cisco IOS XR? ### Response: The Embedded Packet Capture (EPC) feature allows capturing packets that are received or sent on an interface. It is useful for troubleshooting packet drops, routing issues, and application performance problems. Captured packets can be displayed on the console, stored to a file, or exported to an external packet analyzer. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-4-RC_ERR ### Response: (Severity: 4), (Category: ROUTING), (Description: An error occurred in MRIB route collapse operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_SELF_RELOAD ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver encountered a system error which shelf-mgr cannot reload the node. The fabric driver self-reloads instead. The card and its fabric ASICs should have been isolated from the system before the self-reload.), (Recommended Action: Check the health of the shelfmgr process on the dSC RP. If shelfmgr is healthy, and the card cannot self reload, then reload the card with the following command in admin mode: 'reload loc y/SMx/sp', where x is the SM module number that generated the error, and y is the rack that it is in. If manual reload does not work, or if the error recurs, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_CONFIG-7-ERR_MUTEX_LOCK ### Response: (Severity: 7), (Category: OS), (Description: A internal mutex operation has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-BUS_STALL_ADDR_TRACEBACK ### Response: (Severity: 6), (Category: FABRIC), (Description: Certain address accesses were causing bus stall interrupts on the Sapir ASIC. Such addresses are cached by the driver. Subsequently, when these addresses are accessed by the driver, this message is logged to provide a traceback information to help with debugging.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPM-3-ERROR_MESSAGE_GENERAL ### Response: (Severity: 3), (Category: SECURITY), (Description: A message related to Software Policy Manager (SPM) was received. The details of the message are indicated in the message text.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-6-GEN_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: CPU Control FPGA operation information.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAQFPBridgeCtrl-1-TX_ESPI4_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: SPA Bridge ASIC detected a OOF/DIP4/LOS/SEQ/BURST/EOP_ABORT/PKT_GAP Error.), (Recommended Action: Restart the Jacket Process. If the problem persists, reboot the card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-3-SYSMGR_PROC_READY ### Response: (Severity: 3), (Category: PLATFORM), (Description: For HFR number of platform mount retries is 50.Before performing the usb bus scan verify if sysmgr process is ready. This error message will get printed when sysmgr process ready is failed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-CHKPT_ITERATE_NEXT ### Response: (Severity: 3), (Category: OS), (Description: chkpt_iterate_* failed while iterating through the chkpt list.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP_IPC-4-MEM_ALLOC ### Response: (Severity: 4), (Category: SNMP), (Description: SNMP library failed to allocate memory for an object due to low memory conditions in the System.), (Recommended Action: Restart process snmpd check again same senario. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DAPS-6-POOL_UTIL_LOW ### Response: (Severity: 6), (Category: IP), (Description: Utilization dropped below low threshold for specified pool. It shows that the pool is not utilized well at this point of time. If the utilization is always less than low threshold, pool size can be reduced. Pool utilization can be monitored using the command 'show pool ipv4/ipv6 name '.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: Multilink_CLNT-3-REPLAY_REQUEST ### Response: (Severity: 3), (Category: L2), (Description: Replay request for the current node failed because of the reason specified in the format.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlma-4-RECOVERY_FAILED_SINGLE ### Response: (Severity: 4), (Category: L2), (Description: The VLAN MA failed to resynchronize its configuration with another component in the system after an earlier failure, or process restart.), (Recommended Action: After gathering the information specified, it may help to restart the VLAN MA process on the affected node, with proc restart vlan_ma location [location]. If this restart completes without the message appearing again, the problem has been resolved. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACE_TSB_LC-3-ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: ACE TSB Fatal Error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-TASKNAMES ### Response: (Severity: 4), (Category: MGBL), (Description: An error occurred invoking an MDA function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-GENINITFAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An unrecoverable error occurred at system initialization time.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-FILE_NOT_OPEN ### Response: (Severity: 3), (Category: MGBL), (Description: Unable to open the specified file. The error is mentioned as part of the message. This could impact the show run functionality or cause the config loss at upgrade or reload. If this error has happened at the time of doing copying configuration to a file, then copy will not be successful. If this happens during internal system configuration backup then certain configuration will not be updated in the backup. This could result in the config loss at next reboot. If this happens during nvgen server process restart or during initialization after a pie/package upgrade then either command files or config order or partition files are not opened. In which case certain config lines will be missing in the show run.), (Recommended Action: proc restart nvgen_server. If situation persists the Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-RANGE_INIT ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM-7-BAD_NVRAM_VAR ### Response: (Severity: 7), (Category: MEDIA), (Description: Could not allocate memory for a DRAM buffer), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-REPLY_MSG_SENDING ### Response: (Severity: 3), (Category: INSTALL), (Description: An error occurred while sending a reply LWM message to a client. It can be a data or an error number reply.), (Recommended Action: Please check the operation requested and retry. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-2-ETHSERVER_REGISTRATION_FAILURE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Failed to register for getting messages from ethernet server, therefore exiting the process. The system will attempt automatic error recovery by restarting the mbi-hello process several times. If the error does not correct itself, this card will then be rebooted.), (Recommended Action: If the problem persists even after the card is rebooted, please collect the following information and contact your Cisco technical support representative. 1. The console output of the active RSP from user login till the end. Please make sure the above error message(s) are included. 2. (admin)#show install trace mbi-hello location 3. The output of the following CLI commands:) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-WARN_INR_VLAN_SESS_LIMIT_REACHED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions for a particular Inner VLAN on the given access interface has reached the configured maximum.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to assign an interface to an MPLS L3VPN VRF? ### Response: To assign an interface to an MPLS L3VPN VRF, use the 'vrf' command in interface configuration mode. interface GigabitEthernet0/0/0/0 vrf MyVRF ipv4 address 192.168.1.1 255.255.255.0 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-5-BOB_MODE_CHANGE ### Response: (Severity: 5), (Category: L2), (Description: Bundle BoB mode global configuration was changed.), (Recommended Action: Please note that the mode change will apply to new sessions only and the existing sessions need to be deleted and re-created for the new mode to take effect.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_DRV-3-ERR__MIB_SYS_OBJ ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in platform component,the reason for the error mib system object id failed for the particular chassis type.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-6-NMON_CFG_REMOVED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that node is out of its NMON (No MONitor) config now and would be monitored by shelfmgr. While it was in NMON config, node or its card was not being monitored or reloaded by shelmgr, so might have undergone indeterministic state.), (Recommended Action: Reload the node via: #hw-module location <> reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: S2681-3-MUTEX_UNLOCK_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The S2681 UART driver has been unable to unlock access to the UART.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option lockdown feature? ### Response: The MPLS TE path-option lockdown feature disables reoptimization of a tunnel if its current path option is configured with the lockdown option. This prevents a path option from being changed even if a better path becomes available. It provides path stability and predictability. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-TARGET_CFG_DESTROY ### Response: (Severity: 3), (Category: MGBL), (Description: Config process failed to destroy target config buffer.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMATTR-3-SET_REPLY_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The attribute owner library has failed to reply to the client to inform it that a set or clear operation has succeeded. This could result in the client being out of sync with the owner. This may be caused by a transport drop.), (Recommended Action: If the system appears to be in a low-memory condition (check the output of 'show mem summary') then this is most likely the cause of the problem. Please try to fix the low-memory condition. This can also be caused by transport drops, e.g. as a consequence of removing a card. If neither of these cases hold, then contact technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure RSVP interface priority in Cisco IOS XR? ### Response: To configure RSVP interface priority, use the 'rsvp interface' command followed by 'priority' in interface configuration mode. RP/0/RSP0/CPU0:router(config)#rsvp interface GigabitEthernet0/0/0/0 RP/0/RSP0/CPU0:router(config-rsvp-if)#priority 4 4 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEV2-3-BIND_ERROR ### Response: (Severity: 3), (Category: OS), (Description: The sysdb ysdb_bind' function returns error.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-6-MAC_FLUSH_UC_ENABLE ### Response: (Severity: 6), (Category: PLATFORM), (Description: When MACs are being flushed from a bridge, unicasting is disabled (everything floods) for a period of time in that bridge. This message indicates a problem with re-enabling unicast in the bridge.), (Recommended Action: The user should remove and re-configure the bridge domain.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-3-CFG_APPLY_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The ELO Daemon on the specified node was unable to enact a set of valid configuration changes. Future configuration changes may be adversely affected and the protocol is likely not to operate as intended. The problem could be caused by a system resource issue.), (Recommended Action: Attempt to resolve any memory issues before attempting to solve this problem. After system resource isses have been resolved, issue 'process restart' command on the affected node. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_RP_FABRIC-3-INVALID_FGID_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: FGID OOR. Total number of allocated MGIDs has reached system capacity. No more MGID allocations will be allowed until some MGIDs have been freed), (Recommended Action: Reduce igmp snoop route scale) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-4-LSP_OOR ### Response: (Severity: 4), (Category: ROUTING), (Description: When the number of transit LSPs on the router crosses the configured yellow or red thresholds, then MPLS-TE will apply the configured actions for the particular state. This message occurs only if at least one LSP threshold is configured.), (Recommended Action: The operator should monitor the total numbers of transit LSPs and unprotected LSPs on this router and take steps to bring these numbers below the configured threshold.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMIAP-4-INVALID_NETWORK ### Response: (Severity: 4), (Category: IP), (Description: IP address on the management interface on the active/standby RP should be in the same network as the virtual IP address.), (Recommended Action: Change the IP address on the management interface or the virtual IP address so that they are in the same network and are not the same.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARBMGR-7-UNEXPECTED ### Response: (Severity: 7), (Category: OS), (Description: An unexpected condition encountered. This is not necessarily an error.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-CHKSUM_ERR_0_FIA_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Checksum error - 0 from FIA on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-BA_AUTH_FAIL_2 ### Response: (Severity: 3), (Category: IP), (Description: Authentication option is configured on the LMA for the peer MAG or the customer. The PBU is expected to contain authentication option. But it is not received in the PBU. Hence the PBU is rejected.), (Recommended Action: Configure auth-option on the MAG. Optionally remove the auth-option configuration on the LMA from the peer MAG or the customer configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_0_LOSS_OF_SYNC_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Loss of sync on NPU-0 interface on bridge instance-0.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-HW_DETECTED_ERROR_LINK ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cpuctrl driver HW error interrupt handler was invoked and found a port with valid link error registers.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-3-FIELD_GROUP_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: DPA failed to create field-group on this NPU.), (Recommended Action: Verify your hw-module configuration. Otherwise, collect show-tech and contact cisco support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-3-FIRMWARE_UPGRADE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: 'Error was encountered during firmware upgrade operation, the operation was aborted'), (Recommended Action: -Make sure that the FPD pie is installed. -Try reissuing the upgrade commnad. -If the upgrade still fails manually delete files in harddisk:/fpd/ if any exist, and try again. -If the upgrade still fails perform OIR operation on the module and try again when it is ready ('show platform' command in admin mode displays the power modules status). -If the upgrade still fails and it successed on other power modules on the same chassis replace the power module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RAW-3-REG_NETWORK ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the RAW process try to register itself with the network process and net io process for datapath.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FILECOPY-4-NOTIFFAIL ### Response: (Severity: 4), (Category: OS), (Description: The filecopy process failed to send a notification to its clients about a state-transition for a copy request. Users may find the reported duration of a copy operation to be quite large as a result, depending on how long it takes for a client to poll the filecopy_process to see if a state change occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-3-ROOT_DEVICE_BUS_ERROR_THRESHOLD_EXCEEDED ### Response: (Severity: 3), (Category: PLATFORM), (Description: A root device has been detecting a PCIe bus error and it is exceeding threshold. The message has the device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COREHELPER-3-DELETE_CORE_ERROR ### Response: (Severity: 3), (Category: OS), (Description: After copying. Error is specified in message. Failed to delete core file after copy it.), (Recommended Action: Check core file, manually remove the core file to free the disk space. Report this message to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-7-INFO_LOCKING_OPERATION_DISPLAY ### Response: (Severity: 7), (Category: ROUTING), (Description: Display the operation being performed on lock, and the function the operation is taking place in. This will only be displayed in verbose locking debugging.), (Recommended Action: *DEBUG*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-7-DB_EX_DQUEUE ### Response: (Severity: 7), (Category: ROUTING), (Description: An internal software error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_CPP_LCPM_SHOW-7-USAGE ### Response: (Severity: 7), (Category: PLATFORM), (Description: Startup option supplied to SIP_LCPM_SHOW is not valid.), (Recommended Action: Please re-enter the correct option as described in the usage message Example: sh controllers sip-pm interface serial <>/<>/<>/<>/<>/<>:<> loc <>/<>/cpu0) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-ASYNC_WRITE_FAIL ### Response: (Severity: 3), (Category: IP), (Description: Tftp client has failed in writing the packet to the Transmit queue for transmission.This could lead to failure in sending the data over the control ethernet.), (Recommended Action: If message appears only once, then no action is required. Packets will be retransmitted and system should recover automatically. If message appears continuously, then it could indicate a problem with the control-ethernet. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-MUTEX_ERR ### Response: (Severity: 4), (Category: ROUTING), (Description: An error has been returned by the functions used for locking/unlocking an OSPF synchronization mutex.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_GIFT-6-DEBUG_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the GIFT component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-SYSDB_NOTIFY ### Response: (Severity: 4), (Category: OS), (Description: Error in notify handler, Dumper will be impacted.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBUS-6-HBM_BURN_LANE_REPAIR_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that permanent HBM PHY lane repair was completed successfully. Displays the count of lanes repaired successfully.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-WTX_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: WAIPC related message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMITH-3-PROGRAMMING_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The message indicates failure in FPGA re-programming.), (Recommended Action: Please collect the 'show logging -info' output.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WD_SYSMON-5-SYSCALL ### Response: (Severity: 5), (Category: INFRA), (Description: A system call failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SL-7-INIT_LTRACE ### Response: (Severity: 7), (Category: PLATFORM), (Description: This log indicates that Service Logger was not able to initialize tracing. As result of this error, Service Logger will not have any tracings.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_ERRORSLIST ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-ROOT_CERT_MISMATCH_DEV ### Response: (Severity: 3), (Category: LICENSE), (Description: The Production Root Certificate is being used with Development certificates.), (Recommended Action: Please activate the Development Root Certificate from the CLI. (ie. 'test license smart dev-cert enable')) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT-2-CPU_RGMII_RX_LINK_FAIL_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: CPU RGMII TX or PUNT RX has failed.), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. Please verify that the FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-7-VERBOSE_STR_STR ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR_API-2-CHOWN_BUF_FAILED_XFER_CLIENT_TO_SVR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Failed to change buffman ownership from client to server), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VASI_EA-3-STATE_CHANGE ### Response: (Severity: 3), (Category: SERVICES), (Description: While the VASI EA process was checking the state for the specified interface pair, an error was encountered. The interface pair in question may be left in an inconsistent state.), (Recommended Action: It may help to restart the VASI EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-BLOCK_PROTECTION_DISABLED ### Response: (Severity: 4), (Category: DRIVER), (Description: Block protection should not be configured if we are running non-secure boot image. This can happen in two scenario: - User used ccc_write_bootflash without '-d' option so after downgrade to non-seecure boot first article image, the flash was still protected. - The flash is a SPANSION part that was bad configured, so it is protected by default after every power-cycle.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AIB-4-INDEX_REG_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: AIB uses the platform specific adjacency DLL when creating adjacencies. An error occurred while trying to load the DLL, and the adjacency database will not be created. The process will attempt to recovery by restarting. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: Run the following command to check for the presence of the DLL: show dll location | include libaib_index If present, try to restart the AIB process using the following command: process restart aib location If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_EA-4-ERR_MEM_ALLOC ### Response: (Severity: 4), (Category: L2), (Description: The process failed to allocate memory for the specified resource.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. The ppp_ea process should be restarted to recover using the command 'process restart ppp_ea location '.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_SYSDB_EDM_REG ### Response: (Severity: 3), (Category: FABRIC), (Description: The FSDB was unable to become an external data manager (EDM) for the specified path. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-2-BOARD_REV_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: LC CPU controller driver detected a board revision parity error.), (Recommended Action: Reset the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-5-OPERATION_TO_RELOAD ### Response: (Severity: 5), (Category: INFRA), (Description: Specified install operation in the message is going to reload the rack.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_8_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-SIA_LICENSE_NOT_AUTHORIZED ### Response: (Severity: 2), (Category: LICENSE), (Description: The authorization code installed does not contain the requested entitlement tag The authorization code installed does not contain enough counts to satisfy the request. Software upgrades will be blocked once the SIA grace period of 90 days expires. Please check show license platform summary/detail for more information.), (Recommended Action: Generate a new authorization with all licenses required from the virtual account and install that on the router.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What operations can IOS XR processes perform on the SysDB? ### Response: IOS XR processes can perform the following operations on SysDB\n- Retrieve config and state data\n- Create, modify, and delete config data (for config-owning processes)\n- Register for notifications when data nodes are modified\n- Validate and reject config changes (for config-owning processes)\n- Store ephemeral and persistent state data\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSEC_SVI_EA-3-SSC_SEND_SRV ### Response: (Severity: 3), (Category: SERVICES), (Description: A problem was encountered while trying to send a single message to the Service Director. The Service Director may not be up to date with the state of this services on this node, so the associated IPSec SVI interfaces located on this node may fail to forward packets.), (Recommended Action: It may help to restart the IPSec SVI EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_LCPM_SHOW-7-USAGE ### Response: (Severity: 7), (Category: PLATFORM), (Description: Startup option supplied to VKG_LCPM_SHOW is not valid.), (Recommended Action: Please re-enter the correct option as described in the usage message 'Usage: vkg_lcpm_show [-I ] | [-N ]' the node ID should be used in decimal format. Example: sh controllers pm int Ten0/2/0/0 loc 0/2/cpu0, or run vkg_lcpm_show -I TenGigE0_2_0_0 -N 33) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCM_LOGGER-7-DIR_NOT_FOUND ### Response: (Severity: 7), (Category: PLATFORM), (Description: This is an informational message to indicate that a log directory in the storage device is not found. This could be because the device was being formatted. The process will restart to recover.), (Recommended Action: Do nothing) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-NO_ACTIVE_RSP ### Response: (Severity: 0), (Category: PLATFORM), (Description: NPU Crossbar bridge FPGA detected that there is no active RSP in the system, linecard will reset itself.), (Recommended Action: If there are no RSP present or both RSP are undergoing a reload, then this is an expected message. If RSP is boot UP and the problem persists, OIR LC, reseat the LC, check bent pins on backplane connectors.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-SWITCH_FDB_FLUSH_WHILE_AUQ_FULL_TRIGG_WA_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process issued a FDB flush operation while the AUQ was full. When this occurs a secondary AUQ is enabled to avoid FDB flush operation failure. The attempt to enable secondary AUQ workaround is failed.), (Recommended Action: To determine why the secondary AUQ workaround failed, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet' and 'show tech-support ctrace' commands. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does the Replicated Data Service File System (RDSFS) contribute to high availability in IOS XR? ### Response: The Replicated Data Service File System (RDSFS) in IOS XR is used to replicate configuration files and other critical files across RPs for high availability purposes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_TE_PREFIX_DEL ### Response: (Severity: 4), (Category: ROUTING), (Description: The process encountered an error while deleting a prefix from TE.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSUB_MA-3-INIT_FAIL ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: An error occurred during the initialization of IPSUB MA process. The process will restart which should recover the situation.), (Recommended Action: System will retry to start the process and no user intervention required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-5-PWR_SEQ_OLD_FAULT_LOG_DETECTED ### Response: (Severity: 5), (Category: DRIVER), (Description: The fault log saved in power sequencer device from a previous fault event has been collected and raw data has been decoded and saved in the indicated file.), (Recommended Action: The saved file can be collected as part of 'show tech-support ccc' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_OC3_OC12-3-ERR_SFP ### Response: (Severity: 3), (Category: L2), (Description: There is an error detected during SFP initialization. SFP is the pluggable optics on the SPA, SFP initialization may happen when linecard boots up, SFP OIR and SPA process restart. SFP error is for any possible error during the initialization. The optics will not work if SFP OIR operation failed, therefore no traffic will be affected. %s - error message indicating location and the reason of the error), (Recommended Action: - Check the SFP, make sure it is CISCO certified; - Try to do the SFP OIR for a few more times; - If the issue persists, reload the SPA with the command: hw-module subslot 0/x/x reload then test SFP OIR after SPA comes up. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-7-MAP_STAT ### Response: (Severity: 7), (Category: IP), (Description: Initialization of stat file in telnetd session failed , It is created only for statistics purpose.), (Recommended Action: It is just a debug log to indicate mapping to stats failed. Can restart telnetd session for mapping stats.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-ISSU_GROUP_SEND ### Response: (Severity: 3), (Category: INSTALL), (Description: Issu process failed while sending group message ISSU operation will continue without any error. This message send will be attempted again after some time.), (Recommended Action: ISSU manager will retry after sometime. If the issue persists even after tries, contact tac with 'show tech-support issu'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_14_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_NETIO-5-CLEAR_MAPPING_FAILED ### Response: (Severity: 5), (Category: ROUTING), (Description: MPLS could not clear control mapping for underlying protocol.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_0_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SE_INFRA_MGR-3-INVALID ### Response: (Severity: 3), (Category: SERVICES), (Description: The message indicates the message type received is not a valid one.), (Recommended Action: Please provide the following logs: Copy the error message exactly as it appears on the console or in the system log. Issue the cmd command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the cmd output, call your Cisco technical support representative and provide the representative with the gathered information. - Show logging - show services secontroller trace reverse location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE3_CODE_ERR_HIGH_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE3_CODE_ERR_HIGH interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SDS_LIB-7-MEMORY ### Response: (Severity: 7), (Category: INSTALL), (Description: There is not enough memory to continue with current operations.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-TEJAS_INIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in Tejas initialization. This means that Tejas is currently in Factory mode and this will cause the Services PLIM driver initialization to get blocked.), (Recommended Action: Upgrade Tejas with Field FPGA image If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-3-COULD_NOT_REMOVE_CAPS ### Response: (Severity: 3), (Category: L2), (Description: The Ethernet Link OAM Daemon failed to clean up a caps entry in PFI for the named interface. This error is not fatal in itself, although it may prevent OAM from being re-enabled on the given interface until the problem is resolved.), (Recommended Action: Read the error message, and attempt to resolve any issue that may have caused it. Restarting the Ethernet Link OAM Daemon will then allow it to resynchronise with PFI and cleanup the dangling caps. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_MPLS-3-ERR_STR ### Response: (Severity: 3), (Category: L2), (Description: Platform MPLS FIB, error information), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace [common|mpls] all loc <>). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-4-BACKUP_CREATE_FAILED ### Response: (Severity: 4), (Category: L2), (Description: This is an error message in the NPU Driver to indicate that it failed to create/access the specific path on reload.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does priority inheritance solve the priority inversion problem with mutexes? ### Response: Priority inversion occurs when a high priority thread is blocked waiting for a mutex held by a low priority thread. With priority inheritance, when a high priority thread blocks on a mutex, the thread holding the mutex temporarily inherits the higher priority. This allows it to complete its work and release the mutex more quickly, minimizing the delay to the high priority thread. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-3-NETLINK_SOCKET_ALLOC_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: libnl failed to allocate a socket structure while connecting to a new network namespace.), (Recommended Action: If the system is experiencing memory exhaustion, resolve the underlying issue then restart the process. If the problem persists, Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-WDG_SEG_HUNG ### Response: (Severity: 3), (Category: FABRIC), (Description: --), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-INVENTORY_DB_SIZE_ZERO ### Response: (Severity: 3), (Category: MGBL), (Description: Inventory database size is zero. Can happen only if memory is too low.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-EVENT_CONN_NOTIFY_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Whenever any event occurs, a notification will be sent to OBFL manager. OBFL manager will take action based on the notification received. Failing to attach a handler for an event connection will cause OBFL manager to be restarted.), (Recommended Action: If the issue is seen after restart then, collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging 5. show tech-support sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIO-7-ERR_LINK_TRAINING ### Response: (Severity: 7), (Category: PLATFORM), (Description: The Chip-to-Chip connecting link encountered the annunciated link training error. This link connects the two adjacent ASIC and its required to be in trained state for the ASIC's to commuincate control and data reliably over this channel. In general this is a recoverable error as the ASIC driver's will re-train the link on seeing this error.), (Recommended Action: Use the following CLI to make sure the link is properly trained. - show controller eio links all loc <> If this problem is seen consistently, Run the field diags on the board. If it is possible to isolate the trigger point for this failure, collect all the necessary info (condition) that caused the error. Reload the MSC to avoid inconsistent behavior of the system If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP next hop tracking feature? ### Response: BGP next hop tracking is used to speed up detection of next hop changes for routes learned via BGP. It is configured with the bgp nexthop trigger enable command. When enabled, BGP monitors the next hop of installed routes to detect changes, and can initiate route recalculation when changes occur. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2RIB-3-ERR_LOCAL_TO_STATIC ### Response: (Severity: 3), (Category: L2), (Description: Statically configured MAC address is already used by a locally learnt host. Static configuration will take precedence. All traffic destined to MAC address will be forwarded using static MAC configuration.), (Recommended Action: Please assign different MAC address to local host or change statically configured MAC address.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-NLSOCK_CREATE_FAIL ### Response: (Severity: 4), (Category: DRIVER), (Description: CCC driver creates Socket on Black VLAN interface (3073) for communicating with remote cards in the Chassis. If the socket creation fails, then all Ethernet communication from Niantic fails and I2C path is used to reach remote cards.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV_AGENT-6-CPAK_OIRIN ### Response: (Severity: 6), (Category: PLATFORM), (Description: CPAK enity is inserted into the line card inv_agent collects the port data whenever it is presented.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAN-3-OVERCURRENT ### Response: (Severity: 3), (Category: PLATFORM), (Description: ClkCtrl detected an overcurrent condition on Fan.), (Recommended Action: No action will be needed if an overcurrent alarm is set and followed by clear alarm message. if the alarm is persistent or continuous, please contact TAC. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_XRV9K-3-ERR_ISB_INIT ### Response: (Severity: 3), (Category: L2), (Description: bfd_agent encountered an error while initializing its interface database information. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: Collect all the event logs and the output of following command executed from the CLI : 'show process bfd_agent location ' 'show bfd platform trace error location ' 'show tech-support routing bfd') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-REDIST_MAX_PFX ### Response: (Severity: 4), (Category: ROUTING), (Description: We have reached the maximum number of redistributed prefixes), (Recommended Action: Check if redistribution of large number of prefixes is desired and has not been wrongly configured.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the two main features used to secure the forwarding plane in Cisco IOS XR? ### Response: The two main features used to secure the forwarding plane are: 1) Access Control Lists (ACLs) which filter traffic based on configured rules. 2) Unicast Reverse Path Forwarding (uRPF) which helps prevent IP spoofing by verifying that packets are received on the interface that the router would use to forward back to the source. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCU-3-NOT_IN_SYNC ### Response: (Severity: 3), (Category: PLATFORM), (Description: The FPGA and the MCU failed to exchange the configuration information about the board. The user will not be able to start a console tunneling session to this node.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: attestation_agent-2-IMA_DISK_CORRUPT_BLOCK ### Response: (Severity: 2), (Category: MGBL), (Description: A failure occurred during Runtime integrity validation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-3-EEPROM_ERR ### Response: (Severity: 3), (Category: FABRIC), (Description: i2c read failure. Its not under fabric control. Please check I2C trace/logs/component.), (Recommended Action: If the issue persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-6-STALE_DWDM_CARRIER_CH ### Response: (Severity: 6), (Category: L2), (Description: DWDM Controller Interface owner has lost contact with GMPLS Client. The controller shall continue to operate on the existing DWDM Carrier Channel, resync to happen after reconnect with GMPLS Client. This is an informational message.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-CONTEXT_REG_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace context error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace context error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-6-START_SYNC ### Response: (Severity: 6), (Category: INSTALL), (Description: Status information while starting install file sync.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-ASIC_NOT_FOUND ### Response: (Severity: 3), (Category: PLATFORM), (Description: While booting up, CPUCTRL could not find the required ASICs. %s - detail description of which asic can not be found), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-ISM_PD_LIB_SPA_SHUT_ERR ### Response: (Severity: 3), (Category: INSTALL), (Description: The shutdown operation to the indicated SPA has failed.), (Recommended Action: Collect 'show-tech spa location ' for this problem. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-7-NEG_FREE_COUNT ### Response: (Severity: 7), (Category: OS), (Description: --), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-4-ENS_RESYNC_FAILURE ### Response: (Severity: 4), (Category: L2), (Description: 'L2VPN manager is unable to re-connect with peers via ENS/GSP due to ENS API failures. Will retry.'), (Recommended Action: To recover from this state, one may try 'process restart' command. For examples, - process restart gsp - process restart l2vpn_mgr OR Collect 'show tech gsp' and 'show tech l2vpn', and contact Cisco TAC support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCCLASS-2-VCCLASS_LIB_INIT ### Response: (Severity: 2), (Category: MGBL), (Description: A failure occurred during the initialization of the common VCCCLASS library. This probably indicates an underlying more severe problem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-CONNECT_FAILED ### Response: (Severity: 3), (Category: OS), (Description: --), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_ALIGN_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_ALIGN_FAIL interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBIPV6PROTO-3-CONNECT_IO_STATS_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The transport fails to open the ipv6-io stats shared memory), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_13_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_13 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEv2-6-PROFILE_NOT_FOUND ### Response: (Severity: 6), (Category: SECURITY), (Description: Failed to find IKEv2 profile.), (Recommended Action: Configure an IKEv2 profile with respective remote identity) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_HT0_INVALID_CMD ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an invalid command on the HT0 HTDP interface. This means that the HT host core has received a non-posted write command. These packets are not supported and behavior is undefined after this type of packet is received.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT_SWITCH-2-REG_ACCESS_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Register access failure on Punt Switch.), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATSD-3-LTRACE_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: The infrastructure for tracing returned an error.), (Recommended Action: Some Stats tracing will not be available for this process, which will make triage of any Stats problems more difficult. There is otherwise no detrimental effect to this process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-NO_VL_ENDPOINT ### Response: (Severity: 3), (Category: ROUTING), (Description: No IPv6 address was available to use as an endpoint for a virtual link.), (Recommended Action: Configure a loopback interface with an IPv6 address and add it to the specified area.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-7-DEV_DETAILS ### Response: (Severity: 7), (Category: PLATFORM), (Description: Details on the device bus error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-UNSUPPORTED_RACK_NUM_FOR_CONFIG ### Response: (Severity: 3), (Category: FABRIC), (Description: Back-to-back mode is only supported between chassis with rack nums 0 and 1), (Recommended Action: Use chassis with rack num 0 or 1) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_TUNNEL_EA-3-ERROR3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the CRS platform specific code software to indicate some problem with the code. %s - indicates the reason for the failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-7-LOG_DEBUG ### Response: (Severity: 7), (Category: OS), (Description: A debug message logged.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTLIB-4-DBG_INIT_WARN ### Response: (Severity: 4), (Category: SERVICES), (Description: Due to an internal error the debug event was not initialised. The debug feature will not be available for this event.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTP6 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM_PD-3-DLL_CERRNO_REG_FAIL ### Response: (Severity: 3), (Category: L2), (Description: A failure occurred during the registration of the DLL for decoding error codes from the component. This may render certain codes unprintable, but otherwise has no negative impact.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-WARNING_SLOT ### Response: (Severity: 4), (Category: PLATFORM), (Description: An card or slot level function has failed in Shelf Manager. The details are supplied in the msg.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-3-BAD_CS_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: Could not get CS revision info), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check the card is a Cisco approved device if it is externally accessible. Capture 'show filesystem ' together with console log.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_MACSEC-6-LIC_ENFORCE_INC ### Response: (Severity: 6), (Category: OS), (Description: The licensed feature is enabled with appropriate licenses.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_LWM_EVENT_BLOCK ### Response: (Severity: 7), (Category: FABRIC), (Description: Ingressq Event Manager failed to create an event block), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-POLICY_ATTR_FORMAT ### Response: (Severity: 3), (Category: ROUTING), (Description: Length of the tunnel encap attribute formatted during update gen is not same as length received for the same attribute. This could be due to internal error in processing the tunnel encap attribute.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. collect following output arliest convenience, in order for policy change to take effect.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_SBS-3-STATS_BLOCK_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: The process is exiting due to a failure in CPP Infra Stats Block Service.), (Recommended Action: *SH_CMD show controllers pse qfp infrastructure exmem statistics location < > * *SH_CMD show controllers pse qfp 0 infrastructure memory ppe-address location < > * *SH_CMD show controllers pse qfp 0 statistics summary location < > * *SH_CMD show controllers pse qfp 1 statistics summary location < > * *SH_CMD show controllers pse qfp infrastructure exmem statistics location < > *) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRP_UPGRADE-3-WAITPID_CP ### Response: (Severity: 3), (Category: MGBL), (Description: waitpid for the 'cp' process failed Configuration copy thread terminated incorrectly.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_EVC_OPEN ### Response: (Severity: 4), (Category: L2), (Description: SSRP failed to open a connection to an essential service during initialization. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE-7-BLK_BADMAGIC ### Response: (Severity: 7), (Category: OS), (Description: Internal debugging message. For subsequent analysis of magic number corruption, snapshot of running process core dump has been taken.), (Recommended Action: Informational only. Indicates magic number corrupted and has been recovered.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_LQ_SEQ_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue sequence error on XAUI 0 LQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-4-CHKPT_BYKEY ### Response: (Severity: 4), (Category: ROUTING), (Description: The MRIB encountered error while trying to update the checkpoint database. This error may occur during - save a checkpoint record by key - delete a checkpoint record by key), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: USB-2-DEV_EUSB0_TIMEOUT ### Response: (Severity: 2), (Category: PLATFORM), (Description: USB device 0 transaction is taking excess time.), (Recommended Action: The USB device 0 requires immediate service. Please attempt to restart the hd_drv process using command: 'process restart umass-enum'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-0-CARD_RESET_ABORTED ### Response: (Severity: 0), (Category: PLATFORM), (Description: The card reset was aborted because the user has disabled card reset to allow troubleshooting to be performed.), (Recommended Action: Manually reset the card to bring the card back to a known steady state.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPLS-3-VPLS_ID_CONFLICT ### Response: (Severity: 3), (Category: L2), (Description: 'The VPLS ID conflict happens when a configured VPLS-ID value of a ' 'bridge domain equals to default value of VPLS-ID of another bridge ' 'domain. The consequent action in case of conflict ' 'is that the bridge domain with default VPLS-ID remains in the ' 'state of 'NOT Advertised'. '), (Recommended Action: 'Use 'show l2vpn bridge-domain details' to view the states of the ' 'bridge domain with conflicting VPLS-ID and the VPLS-ID value. ' 'The conflict can be cleared by changing the VPLS-ID or VPN-ID ' 'of VFI with default VPLS-ID. ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCI_HAL_SATORI-7-PDMA_DEBUG_INFO4 ### Response: (Severity: 7), (Category: PLATFORM), (Description: %s- Function name. %d- Line number. %s- Conversion message. %x- REturn value.), (Recommended Action: debug info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-3-POWER_REQ_NOT_DEFINED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The card type read from the CAN Bus is not recognized to be valid. The shelfmgr will not bootup this card. The 'show platform' CLI will not show a card for this slot.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-3-INVALID_TYPE_CONVERSION ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: IM converted a type of size_t into either a uint32_t and uint16_t, when it expected the value in the size_t variable to be small enough to fit into the new variable type. However, the conversion caused the value to change, indicating that some data was lost. This is likely to leave the system in an inconsistent state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_FPGA-4-HW_WARNING ### Response: (Severity: 4), (Category: L2), (Description: Plim datapath fpga errors. Typically these indicate errors detected by the ASIC. Too many of these errors might indicate problem with the board, and may trigger packet loss. These errors seen during LC boot up or SPA OIR are harmless.), (Recommended Action: Check if spa is seating properly Check whether process 'plaspa_server' is up and running. Check if the linecard reported any other errors and/or traffic loss was observed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-POP ### Response: (Severity: 3), (Category: HA), (Description: An unmatched stack pop operation was detected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-2-CLKCTRL_DACK_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Interrupt controller driver detected an data ack error from Timing and CPI controller FPGA), (Recommended Action: Please try to correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-CF_MBE_ERR_FIA00 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA00 channel FIFO multi-bit error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA_MGR-4-MPA_SHUTDOWN ### Response: (Severity: 4), (Category: PLATFORM), (Description: Shutdown command received for MPA), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TSEC-6-OPERATION_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The particular operation mentioned in the message gave an informative message. This is not a failure.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different OSPF network types and how do they differ? ### Response: The OSPF network types are\n- Broadcast (default for Ethernet, elects DR/BDR)\n- Point-to-point (default for HDLC, PPP, POS, no DR/BDR)\n- Non-broadcast (NBMA) (default for Frame Relay, ATM, elects DR/BDR, requires neighbor statements)\n- Point-to-multipoint (treats NBMA as collection of P2P links)\n- Point-to-multipoint non-broadcast (P2MP but neighbors must be configured)\n- Loopback (represents a loopback interface, no hellos sent)\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-GROUP_CREATE ### Response: (Severity: 3), (Category: OS), (Description: Unable to create PLACEMENT_GSP_GROUP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEV2-0-SVC_EMERG ### Response: (Severity: 0), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATS_INFRA-6-ERR_STR_RETURN ### Response: (Severity: 6), (Category: PLATFORM), (Description: An error occurred in stats infra component. The error string and return value gives the reason for the error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-3-GET_MEM_FAILED ### Response: (Severity: 3), (Category: OS), (Description: 'Failure in memory allocation.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_CPM-4-AUTHENTICATION_FAILURE ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The information provided by the satellite could not be authenticated correctly. Examine the error message for the specific error.), (Recommended Action: Verify that the correct satellite is connected and that there are no blocked processes or packet drops.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESDMA-6-ESD_CONN_FOUND ### Response: (Severity: 6), (Category: INFRA), (Description: ESD on the given location is up or started. Hence connection between ESD and ESDMA has been found.), (Recommended Action: Check on the esd process in the given location) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-3-NODEID_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: An error happened for a nodeid operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_4_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias less than or equal to the low laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-2-PAYG_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The port is enabled without the necessary PAYG license.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFL_MGR-3-GET_EID_INV_XML_OPEN_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: OBFL failed to open xml file associated with location. A combination of board's HW Types, HW Version, PID etc., may be bad.), (Recommended Action: Check inventory traces if the inserted slot is updated correctly. Check if CCC shows fake card info due to idprom related read failures.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-INIT_PRINT ### Response: (Severity: 4), (Category: PLATFORM), (Description: Debug message), (Recommended Action: Debug message) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-INTF_THRESHOLD_BREACHED ### Response: (Severity: 6), (Category: L2), (Description: A threshold has been breached in the hardware. This is an indication of a deteriorating link.), (Recommended Action: No specific IOS-XR action needs to be performed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QUEUE-7-QCOUNT ### Response: (Severity: 7), (Category: OS), (Description: An internal software error occurred.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-3-STATS_ALLOC_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The OFA failed to allocate statistics entry for the feature. Number of feature entries requiring statistics entries has exceeded statistics entries reserved for that feature on this line card. As a result, accouting for the failed feature entries is not available. There is no impact on ability to apply the feature in hardware.), (Recommended Action: If per feature accouting is needed, reduce the feature configuration on this line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-3-INIT_SVR_ERROR ### Response: (Severity: 3), (Category: MEDIA), (Description: Media server is unable to initialize itself. Media server will exit and retry.), (Recommended Action: Collect system log information. Contact TAC for support if the condition is unrecoverable.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBUS-3-HBM_MBIST_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates possible fault with the NP HBM memory. Displays the global error associated with the MBIST operation.), (Recommended Action: The line card needs to be returned for repair.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-3-DIAGNOSTIC_ERROR ### Response: (Severity: 3), (Category: DIAG), (Description: An Error message for the diagnostic.), (Recommended Action: Take a copy of ctrace buffer : Error, info and debug message of the process and node-id mentioned in the error message using 'show diagnostic trace location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHOWTECH-7-DEBUG ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-4-CHKPT_SAVE_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The Ethernet Link OAM Daemon failed to save the checkpoint entry for the given interface. Although this error is not immediately fatal, information will be lost if the process restarts before successfully saving its checkpoint data.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_lite-3-ERR_SHMEM_TRNC_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Attempt to truncate the shared memory file fails), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SE_P2MP_SRVR-2-RECV_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Some or all the cores didn't respond for a configuration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-MAC_0_TX_FIFO_OFLOW_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: MAC on NPU-0 had transmit fifo overflow on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-SYSDB_REG_NOTIFY_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Registration fail for sysdb notification. OBFL will fail to function as OBFL need to get notifications for every config change.), (Recommended Action: Please restart the process manually. If the issue is seen after restart then, collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging 5. show tech-support sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-6-NEW_NEIGHBOR ### Response: (Severity: 6), (Category: L2), (Description: A new entry has been added to the CDP neighbors table. Notification of new CDP neighbors requested through 'cdp log adjacency changes'.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-2-LSP_MTU_LOW_ERR ### Response: (Severity: 2), (Category: ROUTING), (Description: The LSP MTU is so low that the LSP overhead can not fit in the LSP. As a result no data can be advertised in LSPs. Please increase the LSM MTU size.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-CANT_GET_NODE_TABLE ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the infrastructure is behaving incorrectly. The Package infrastructure could not create a required new node table, so processing of the current operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-REDIST_MAX_PFX ### Response: (Severity: 4), (Category: ROUTING), (Description: We have reached the maximum number of redistributed prefixes), (Recommended Action: Check if redistribution of large number of prefixes is desired and has not been wrongly configured.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-4-DISPLAYING_DEFAULT_HOSTNAME ### Response: (Severity: 4), (Category: MGBL), (Description: Unable to bind to sysdb to get hostname hence displaying default hostname.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC9 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-6-DEVICE_ACTIVATED ### Response: (Severity: 6), (Category: OS), (Description: The device on the node is activated for onboard logging.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_UTIL-7-DUP_KEY ### Response: (Severity: 7), (Category: HA), (Description: A client of the CDM library attempted to create an object with a key that was already in use.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-3-MGR_SHUTDOWN ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: When 'vpdn' configuration is removed, the VPDN Manager (vpdn_mgr) process will shutdown and exit. Something has failed in this proceedure and may prevent VPDN from functioning later or releasing resources.), (Recommended Action: Allow VPDN Manager to exit and validate with 'show proc vpdn_mgr'. If it does not exit use 'proc restart vpdn_mgr' to recover. If the problem persists, contact Cisco support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_SERVICE_EA-3-ERR_PRM_ERROR ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected from prm operation), (Recommended Action: When this issue happens, this could result in inconsistent hardware state If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-4-CAPABILITY_PARSE_FAILURE ### Response: (Severity: 4), (Category: MGBL), (Description: A failure was encountered while trying to read in capability data used to create the capability database for the Central Config Validator (CCV). CCV will still attempt to validate configuration, however it may be using incorrect values in situations where the configuration depends on the capabilities of the platform.), (Recommended Action: The cause of the capability data parsing failure should be investigated, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-2-ASIC_ERROR_CIH_INIT_THRESHOLD_CARD_SHUTDOWN ### Response: (Severity: 2), (Category: PLATFORM), (Description: Uncorrectable asic errors occured on card), (Recommended Action: ASIC errors that are uncorrectable have occured and exceed the threshold. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_9_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM-4-BAD_NVRAM_MAP ### Response: (Severity: 4), (Category: MEDIA), (Description: Mapping of Nvram Failed), (Recommended Action: 'Check for 2MB size NVRAM') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-USING_OLD_RTRID ### Response: (Severity: 4), (Category: ROUTING), (Description: OSPF failed while attempting to allocate a router ID from the IP address of one of its interfaces due to an unexpected internal problem.), (Recommended Action: Use \'clear ip ospf process\' to force another attempt to find a valid router ID. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-4-LOST_EVENT ### Response: (Severity: 4), (Category: SECURITY), (Description: The process failed to receive an event from the Operating System. As a result, some aspects of the process may fail to function correctly.), (Recommended Action: If erroneous behaviour is seen, restart the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-MAC_1_RX_FRAME_ERR_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: MAC on NPU-1 received an errored frame interface on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-4-INSTALL_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: ISO image installation running on the indicated card is reporting a warning condition. This condition does not stop the installation operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-CHKPT_CREATE ### Response: (Severity: 3), (Category: OS), (Description: chkpt_create failed while creating an object in a chkpt table.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-6-BACKUP_CONNECTION_DOWN ### Response: (Severity: 6), (Category: HA), (Description: RMF has determined that the connection to the backup process groups location has gone down.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-7-APPLY ### Response: (Severity: 7), (Category: SYSDB), (Description: An apply function failed while a verifier was scanning SysDB (e.g. after restarting), so the operational state of the system may be inconsistent with the running configuration.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_FIA__EVT_MGR_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: Fia event manager initialization failed), (Recommended Action: Restart the process using the CLI in exec mode - process restart fiarsp If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR_DLL-3-UNCORR_FSB_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An uncorrectable error has occurred on the FSB (Front Side Bus) of the Linecard's CPU complex. The message will display the name and description of the error along with the error log. If the log indicates 'no log', that means the error is a subsequent error. 'Detected MCERR#' and 'B-INIT' errors do not have a log as well. The linecard will reload after a certain threshold of number of occurances have been reached.), (Recommended Action: Contact support with the required information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FDI-3-ERR_SEND_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: An unexpected error occurred while sending an message. Process will restart to recover from this error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_LCP-4-UNEXPECTED_AAA_RESPONSE ### Response: (Severity: 4), (Category: L2), (Description: AAA has sent a response which is unexpected or malformed in the way explained in the message. The error may cause the interface to be left in what should be a transient state permanently.), (Recommended Action: Check the output of 'show ppp interface' for the interface with the problem. If the interface has been left permanently in an unauthenticated state, then it can be manually cleared using the 'clear subscriber' command. Note that if the interface has come up successfully then the unexpected AAA response will probably not have caused problems.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-WRONG_PLATFORM ### Response: (Severity: 3), (Category: DRIVER), (Description: The image loaded on the hardware is not correct, verify the hardware platform and image name.), (Recommended Action: Check for the right image to be used.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_ARL_LIB-3-LOCK_NOT_RECOVERABLE ### Response: (Severity: 3), (Category: L2), (Description: Failed to make the mutex in consistent state results in not recoverable state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCM-3-SYSDB_REG ### Response: (Severity: 3), (Category: L2), (Description: Connection Traffic Table manager registration with SYSDB verification errored somehow, the argument will show the reason of the error.), (Recommended Action: This is a corner case and should not occur multiple times. Collect required info if it persists.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_1_TS_CORE_ERR_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: NPU-1 timestamp core error on bridge instance-2.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLU-4-TBM_INCONS_CORRECTED ### Response: (Severity: 4), (Category: PLATFORM), (Description: Errors occured in the HW TBM tables have been auto corrected. No action needs to be taken. This is informational message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_FI_INTR_RCTL0_LO_EOP_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_FI_INTR_RCTL0_LO_EOP_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-4-MIB_CACHE_TIMER_MODIFY ### Response: (Severity: 4), (Category: ROUTING), (Description: The cache-timer for a MPLS-TE MIB has been changed to below the \ default value or disabled entirely. This will result in SNMP directly \ retrieving data from MPLS-TE more frequently; if frequent MIB queries \ are made this may place significant load on the system and result in \ degraded performance.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-4-HARDWARE_READ_FAILURE ### Response: (Severity: 4), (Category: PLATFORM), (Description: Detected hardware error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_HAL-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: This error message in PLATFORM FIB HAL indicate that some kind of system DB registration failed or HAL engine object initialisation failure), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show logging, show version, show platform, show install active, show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCMCIAD-3-CARDMGR_START_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: PCMCIAD ws trying to start cardmgr process but failed with specified reason), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture console log and dump the process core of pcmciad) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-INVALTUPLEPATH ### Response: (Severity: 3), (Category: MGBL), (Description: 'The path of the tuple is invalid'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-PSS_SNAPSHOT_ERR ### Response: (Severity: 3), (Category: OS), (Description: Persistent Storage Service snapshot error.), (Recommended Action: Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STANDBY-3-ERR_IM ### Response: (Severity: 3), (Category: IP), (Description: HSRP has failed to retrieve required information about the interface from the Interface Manager.), (Recommended Action: Check to see if there are any other errors on the system which may indicate a general service-related problem and restart those services. If the problem is isolated then restart HSRP. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-6-SESSION_STOPPED ### Response: (Severity: 6), (Category: L2), (Description: A best-effort attempt to stop a session has been made. If an error occurred in cleaning up the session on a particular LC the SESSION_NOT_STOPPED message will be generated on that LC.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-EVENT_INIT_EVENT ### Response: (Severity: 3), (Category: MGBL), (Description: The call to event_init_event() failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_MAP-3-IPARM_RELATED_FAILURE ### Response: (Severity: 3), (Category: ROUTING), (Description: A problem occurred when a call to one of the IPARM APIs was made.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp mapping-agent trace interface activities command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp mapping-agent trace interface activities output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp mapping-agent trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp mapping-agent trace output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-3-MEM_ALLOC_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The policy_repository process failed allocated memory for the operation specified.), (Recommended Action: The policy_repository process may function properly in the future but the operations associated with this configuration are likely in an inconsistent state. Restarting the policy_repository may correct the situation if the memory is being consumed by this process; otherwise restarting the procees that is consuming the memory may be advisable. Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_MEM_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-PKT_LEN_MAX ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The range of supported packet-length values is limited and must be less than or equal to the specified maximum value.), (Recommended Action: Modify the packet-length values to not exceed the specified max value and re-apply the ACL.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-VERIFYD_EXIT ### Response: (Severity: 3), (Category: MGBL), (Description: tty_verifyd exit with failure. TTY related configuration might have not applied.), (Recommended Action: Please check the configuration and reapply if required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-CF_MBE_ERR_FIA01 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA01 channel FIFO multi-bit error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-3-WARNING ### Response: (Severity: 3), (Category: L2), (Description: A runtime error occurred in ASR9K IPv4 FIB module. The reason for the failure is also displayed. Please call Cisco Support with the error information.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv4] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REBOOT_LIB-3-INVMGR_HDL_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: Failed to create inventory manager handle.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-IP_POOL_FREE_FAILURE ### Response: (Severity: 3), (Category: SECURITY), (Description: An error occurred while attempting to free an IP address back to the local pool), (Recommended Action: 'It may be possible to rectify the problem by restarting ip_ap process.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLICEMGR-3-PCI_ERROR ### Response: (Severity: 3), (Category: LIBRARY), (Description: NPU asic pci error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-PLIM_SERVICES_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in initialization of PLIM Services driver. If this occurred during process startup or RP Switchover, then the process may be restarted.), (Recommended Action: Restart the plim_services process (process restart plim_services location <>) If the issue persists, do a cold reboot Services PLIM MSC.If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4MC_STATIC-7-ERR_IDB_INIT ### Response: (Severity: 7), (Category: ROUTING), (Description: Internal error. Cannot create initialize IDB list), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_SNOOP-7-INIT_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the IGMP Snooping module in the platform L2FIB SNOOP component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_1_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the is-type command in IS-IS? ### Response: The is-type command is used to configure the IS-IS router type. The options are level-1 (L1), level-2-only (L2), and level-1-2 (L1/L2). An L1 router has neighbors only in the same area. An L2 router has neighbors only in the backbone. An L1/L2 router has neighbors in the same area and in the backbone and can route traffic between the two levels. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-UNEXP_EVENT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The system has received an MDR event that is not supported.), (Recommended Action: File a defect report.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-REPO_METADATA_GENERATION_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: Automatic generation of repository metadata failed. This may indicate that there is a problem with the packages in the given directory, or that createrepo_c encountered an error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CMN_DSTRIB_GSP_FBRC-3-ERR_DEBUG_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: Debug initialization failure for GSP fabric.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-1-ERR_HW_THRESHOLD_RELOAD_NODE ### Response: (Severity: 1), (Category: L2), (Description: A hardware error is detected on the PLIM, and the error threshold has been crossed. Software will take action as described in the error message to try to contain or recover from the error. The hardware error and the software recovery action will cause linecard reload. Device: %s%s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Threshold of %s - the defined threshold for this error. Software action: %s - the action that software will take to try to contain or recover from the error.), (Recommended Action: If the message recurs, diagnostics should be executed on the PLIM and MSC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_SYSLOG_PRX-3-ERR_DETAILS ### Response: (Severity: 3), (Category: SECURITY), (Description: Client address, error, error description.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-1-PWR_DRIVER_NOT_READY ### Response: (Severity: 1), (Category: PLATFORM), (Description: The power module drivers have not reported any available power supply budget for the chassis. Since the power budget of the system is unknown the shelfmgr is unable to bootup line cards.), (Recommended Action: 1. Please reload the router to see if the power module drivers will report available budget and hence the line cards can be booted up by shelfmgr: admin reload location all 2. If the error persists, please reseat the power modules for this chassis and verify their insertion via the following CLI command: admin show environment power 3. If the error still persists, please collect the following and contact your Cisco technical support team: admin show platform show logging local location show tech-support shelfmgr show version show controllers power-monitor trace) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCTRL-3-SET_BOOTORDER_PXE ### Response: (Severity: 3), (Category: INFRA), (Description: SCTRL NCS5K Error in Setting BootOrder for PXE, for exact info view the '%s' msg displayed.), (Recommended Action: Check Connectivity to PXE server . In case of repeated failure contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-7-CHKPT_TBL_RESET ### Response: (Severity: 7), (Category: SERVICES), (Description: Failed to reset a record in the given checkpointing table.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-RED_STATE_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Error encountered during redundancy state transistion.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-PROC_OPEN_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Could not open the process file system), (Recommended Action: Collect the following data and raise DDTS. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-INTERNAL ### Response: (Severity: 7), (Category: MGBL), (Description: The code has performed an action which should not be possible.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-SATELLITE_LMEP_CREATE_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The local MEP for a Satellite Fabric Link could not be created. This means CFM will not run over the Satellite Fabric Link, and so will be unable to detect Satellite Fabric Link failures.), (Recommended Action: The creation of the local MEP can be retried by unconfiguring CFM on the Satellite Fabric Link and reconfiguring again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_8_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_8 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UCP_OLM-7-ROUTER_ID_ZERO ### Response: (Severity: 7), (Category: ROUTING), (Description: All existing OUNI connection will NOT come up until a Global or OUNI router ID value will be specified using CLI.), (Recommended Action: Please specify a global router ID. If this is not desired, please specify a node-id for optical UNI using: (config#) optical-uni node-id CLI. Make sure that this value matches the router ID used by MPLS Traffic Engineering application. If optical UNI connections do not come up even after entering the router IDs change, please make sure that MPLS TE application is using the same router ID as specified in the global router ID. Please refer to the QFT3 Caveat list for optical UNI router ID selection.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-7-SYSERR ### Response: (Severity: 7), (Category: HA), (Description: This message signals an unrecoverable condition reported from the underlying system services. The severity of such errors cannot be determined locally by Checkpointing, so it treats them all such conditions as non-fatal, transient errors. The chkpt user must abort its immediate operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-4-PLATFORM_INFO_FAIL ### Response: (Severity: 4), (Category: L2), (Description: Failed to fetch Header base address & Window size information from shmwin window file, due to one of the following reasons: 1. Invalid arguments passed to the function 2. Error occured while opening/accessing the file 3. Required information not available in the file), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-TFTP_DEBUG_INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: Failed to initialize debugging services for CE-TFTP server. The system will continue to funtion as this is not a system impacting issue.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_PLL ### Response: (Severity: 3), (Category: FABRIC), (Description: While initializing the transmit slices of the FIA, the driver failed to lock the PLL. This is caused due to a clock synchronization problem between the MSC and the fabric board. This would result in loss of connectivity and bandwidth to affected fabric board.), (Recommended Action: Collect the required information indicated below. Also, run the field diags and the health check. If the health check or diags fail, then initiate the RMA process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-4-CHKPT_DEL_TABLE ### Response: (Severity: 4), (Category: ROUTING), (Description: The MRIB encountered error while deleting a checkpointed table. This can lead to system memory leak.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS_MODULE-2-DEV_OPTICS_BAY_SUPPORTED_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: An supported error was detected during optics initialization. This error is reported when the optics type can not be determined or it is not supported on the platform. The optics is the pluggable optics on the line cards.Optics initialization may happen when linecard boots up, optics OIR and line card process restart. The optics will not be enabled if an optics supported error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the optics with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG_PLAT-7-NULL_PTR ### Response: (Severity: 7), (Category: INSTALL), (Description: An internal error has occurred in an application causing it to send invalid data to the packaging infrastructure. The current request or operation may not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-CARD_MODULE_FROM_NODEID_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: Parser relies on invmger API to get card number and module number. But the API had failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_LIB_COMMS-6-INFO ### Response: (Severity: 6), (Category: HA), (Description: Internal Information messages), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVM-3-MUTEX_UNLOCK ### Response: (Severity: 3), (Category: OS), (Description: An Event Manager library function was not able to unlock mutex.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SYSDB_GET_FAIL ### Response: (Severity: 7), (Category: OS), (Description: Dumper stored various config related data in sysdb and it failed to get sysdb item. This might impact the dumper.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-BFD_SESSION_NOT_FOUND ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to locate a BFD session for a given adjacency. If necessary IS-IS will reconnect to the server to correct.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-3-INIT_FAILED ### Response: (Severity: 3), (Category: L2), (Description: Optics initalisation failed during insertion handling.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_EVM_CRE_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to create an Event Manager to receive events in the specified thread. This is most likely to be caused by a resource starvation problem, but may also be due to an internal programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-BPM_AS_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: This warning will show up for possible out of order system database notification.), (Recommended Action: Should not attempt to publish anything until Autonomous System number is set.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPIDB-2-INIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: A run time error occurred while initializing the lc idb on the linecard. The reason for the error is dispalyed. Please call Cisco Support with the error information), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an access list? ### Response: To configure an access list in Cisco IOS XR, use the 'ipv4 access-list' command in global configuration mode. RP/0/RP0/CPU0:router(config)#ipv4 access-list ACL1 RP/0/RP0/CPU0:router(config-acl)#permit tcp any any eq 80 RP/0/RP0/CPU0:router(config-acl)#exit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-3-CRITICAL_ERROR ### Response: (Severity: 3), (Category: L2), (Description: A critical error occurred in jacket driver which involves exiting the process. The jacket driver will restart and unless the same error occurs on the next attempt the driver will function normally. If the error is persistent, it indicates the system error or HW error which needs further investigation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can BGP routes be filtered on IOS-XR? ### Response: BGP routes can be filtered on IOS-XR by applying RPL policies using the route-policy command in the neighbor address family configuration. Policies can match on various attributes using defined sets and apply actions to filter or modify path attributes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: S2681-3-THREAD_CREATE_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The S2681 UART driver was unable to create a thread for the interrupt handler.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-6-EOBC_CHIP_DOWN_RECOVERY_FAILED ### Response: (Severity: 6), (Category: PLATFORM), (Description: Hooper shows the register reading 0xffffffff. Recovery action fails to recover the chip), (Recommended Action: 'show controllers epm-switch port-mapping location *') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-EXTCOMM ### Response: (Severity: 3), (Category: ROUTING), (Description: The import table list associated with an extended community set could not be created. This can occur if there is insufficient memory to allocate the import table list, or the number of importing tables exceeds the hard coded limit on the number of tables that a route may be imported into.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_0_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature less than or equal to the low temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CPAK with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTR0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOADPATH_UPGRADE-7-NULL_PTR ### Response: (Severity: 7), (Category: INSTALL), (Description: Unexpected parameter value passed to function.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-WARN_RID_SES_THRESHOLD_EXCEED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions on a particular Remote ID has exceeded the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to reload the router in Cisco IOS XR? ### Response: To reload the router, which restarts the IOS XR operating system, use the 'reload' command in EXEC or administration EXEC mode. RP/0/RSP0/CPU0:router#reload <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-3-PFM_IF_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: PFM module issue. Message string details the exact issue.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - sh platform - sh processes vic location <> - show tech-support ethernet interface) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_FPOE_DB_CORR_ECC_ERROR_LNK1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast FPOE correctable ECC error on link 1), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-3-FILE_OPEN_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occured while opeining a file.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ALLOCATOR-7-SIZE_MISMATCH ### Response: (Severity: 7), (Category: OS), (Description: The block size in the memory passed into the allocator module does not match that passed in by the caller on initialisation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB_ALARM-3-NEGATIVE_GLOBAL_MAC ### Response: (Severity: 3), (Category: PLATFORM), (Description: A system wide internal MAC counter is corrupted due to software error. The problem can cause data plane learn more MAC addresses than global MAC limit. When this happens, EVPN control plane may lose some MAC routes.), (Recommended Action: If the HW MAC table is not close to full, no action is needed. If the HW MAC table size is at or over the system MAC limit, there are two options for recovery: 1) Line card reload. 2) l2fib_mgr process crash on the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-WARN_MAC_IWF_SESS_LIMIT_REACHED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of IWF PPPoE sessions from a particular MAC address has reached the configured maximum.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option dynamic feature? ### Response: The MPLS TE path-option dynamic feature allows MPLS TE tunnels to be routed dynamically by the MPLS TE software, using a path calculation algorithm that considers the tunnel's constraints and attributes. Dynamic path-options do not require an explicit path to be configured. They provide flexibility in path selection. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_LOS_PORTQ ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-FGID_CNTRL_REG_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while registering client information to FGID aggregator.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-4-FABRIC_UNSUPPORTED_FABRIC_MODE_BOARD_TYPE ### Response: (Severity: 4), (Category: FABRIC), (Description: Unsupported board in slot for the fabric mode configured.), (Recommended Action: Check running configuration if five fabric mode is configured In this mode, it is expected certain LC board types such as LC36 will not be supported this. Remove this board or remove the configuration if it is desired to bring up this board) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_12_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_12 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-DEFAULT_PATH_TMP ### Response: (Severity: 6), (Category: OS), (Description: Notify that the default path has been set to /tmp/dumper), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-USER_INPUT_TIMED_OUT ### Response: (Severity: 6), (Category: INFRA), (Description: The user was asked for some input on the CLI. However, no response was given within the required time period, and the so the operation was cancelled.), (Recommended Action: Re-run the operation, and answer any queries on the CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TXLIB-3-INV_PEER ### Response: (Severity: 3), (Category: ROUTING), (Description: Received Socket accept request from Unexpected Address or Port Number. Connection will be rejected.), (Recommended Action: Configure the correct address and port number for the peer.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-PARAMETER_BAD_TRANSID ### Response: (Severity: 7), (Category: INSTALL), (Description: An invalid parameter has been unexpectedly passed to the Install infrastructure. This is a coding error. The current request or operation will not be completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How do you upgrade from one major IOS XR release to another using the 'mini' PIE? ### Response: To upgrade from one major IOS XR release to another using the 'mini' PIE\n1. Copy the new 'mini' PIE and any required optional PIEs to the router's disk\n2. Use the `install add` command to unpack the 'mini' PIE and optional PIEs\n3. Use the `install activate` command to activate the new software\n4. Commit the new software set using `install commit`\n5. Reload the router for the new version to take effect\n\nNote: All installed optional PIEs must match the version of the new 'mini' PIE.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSC-7-ERR_DEBUG_INIT_EVENT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric statistics client library encountered debug facility initialization failure. When this error happens, the library will not able to enable debug.), (Recommended Action: Restart Fabric statistics client manually if the error is persistent.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-5-RECV_LACP_MAC_TWICE ### Response: (Severity: 5), (Category: L2), (Description: EVPN receives the CE's System ID from LACP for use in EVPN as the PBB-BSA on two or more interfaces. It cannot be used more than once as a PBB-BSA MAC.), (Recommended Action: Configure a static Ethernet Segment on the conflicting interface, and a static backbone-source-address MAC to use.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRIVER_LITE-3-ERR_SHMEM_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: Attempt to init/open the shared memory fails), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: adminexec-3-GETLINE_DATA ### Response: (Severity: 3), (Category: MGBL), (Description: 'lib/ui library API related to getline has failed'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-MEM_CLEAR_FAILED ### Response: (Severity: 3), (Category: L2), (Description: CPP driver failed to clear memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIB-3-BAG ### Response: (Severity: 3), (Category: SNMP), (Description: A problem occurred while encoding or decoding information from a bag.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBUS-7-API_FILE_OPERATION_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: mbus API debug information indicating the file and the operation on the file that failed), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCCLASS-3-CONSUMER ### Response: (Severity: 3), (Category: MGBL), (Description: These are general ATM VCCLASS client API failures.Internal failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-2-POGO_TCAMS_NOT_RELEASED_FROM_RESET ### Response: (Severity: 2), (Category: PLATFORM), (Description: POGO tcams not out of reset), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_9_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_9 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_SYSDB_BAG_FREE_INDIRECTIONS ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-INVALID_BOARD_CLASS ### Response: (Severity: 3), (Category: DRIVER), (Description: IOFPGA driver cannot handle the detected IOFPGA board classification.), (Recommended Action: This error is seen when there is a problem in internal software coding, it should not be seen under normal operation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_2_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power greater than or equal to the high Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_1_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_1 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QAD_SERVER-3-SHMWIN_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Shared memory access operations like init,open or bind might have failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-LISP_EID_TBL ### Response: (Severity: 3), (Category: ROUTING), (Description: This reflects a failure in the maintenance of the lisp eid table used to control lisp decapsulation in the specified VRF.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-2-NODE_BRINGDOWN ### Response: (Severity: 2), (Category: L2), (Description: The NPU driver was unable to perform a critical function and must trigger a node bringdown to effect recovery.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-3-MISSING_CHASSIS_SERIAL ### Response: (Severity: 3), (Category: TOPOLOGY), (Description: Chassis is either not programmed with correct serial number or could not read idprom.), (Recommended Action: execute - contact cisco support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_FPD-3-WRONG_OIR_STATE ### Response: (Severity: 3), (Category: L2), (Description: The FPD image update operation could not be performed because the specified SPA is not in the correct state. The correct OIR state for the SPA is specified in the message text.), (Recommended Action: Do not perform the update operation while the SPA is in the middle of a reload operation or while it is being initialized. Wait until the specified SPA is in the correct OIR state and retry the operation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_3_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_MA-6-CLEAR_ALL_STATS ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-4-PROBE_SCHEDULE_FAILURE ### Response: (Severity: 4), (Category: INFRA), (Description: An error occurred while scheduling a probe, or scheduling a packet within a probe. This could indicate a resource issue. The impact of this error is that some results will be missing for this operation; in some cases, no further results will be collected for this operation.), (Recommended Action: No further action is needed. However, if the problem persists, it may be possible to recover by restarting the protocol process on the affected node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the instdir-cli process in IOS XR installation? ### Response: The instdir-cli process provides the user interface for performing installation-related tasks. It allows the user to execute install commands from the CLI. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-OPEN_SYMLINKS_FILE ### Response: (Severity: 3), (Category: OS), (Description: An expected startup configuration file for QSM could not be opened. This could be due to a problem with the installed media or file system damage. QSM will continue startup-up, but some system functionality may be impared.), (Recommended Action: Your installed file system may be corrupted. Perform a format and re-install to fix it. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-TSPI_CAL_ECC_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: TxSPI Calendar ECC single bit error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPT-3-LTRACE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ltrace start failed in cpt engine. %x-Return value.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_SE-6-GENERIC_EVENT ### Response: (Severity: 6), (Category: PLATFORM), (Description: Service Interface Server related provisioning info.), (Recommended Action: No action is required. This is informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-ISSU_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: During ISSU upgrade - some NP memory capabilities are reduced temporarily while new NP image and programming is coming online. Due to a combination of high traffic rate and customer features configured - the NPs utilization is near a high water mark. This can lead to user traffic drops during the ISSU upgrade. This can be avoided by reducing the traffic load on that NP.), (Recommended Action: Reduce traffic and start ISSU again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPA_1P_OC192-3-GET_NODEID_ERR ### Response: (Severity: 3), (Category: L2), (Description: SPA driver failed to obtain either its node ID or extract rack/slot/instance information (having obtained the node ID).), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-DLL_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred whilst trying to open or initialize a DLL. The process will be restarted if this error occurs during process startup.), (Recommended Action: If the process has been restarted and the problem recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND-3-ERR_IM_BIND ### Response: (Severity: 3), (Category: IP), (Description: The IPv6 Neighbor Discovery (ND) process (ipv6_nd) failed in an attempt to communicate with the Interface Manager (IM) process (ifmgr). This is normally a transient problem that will correct itself. However, IM is a vital partner in much router activity, including ND and IPv6 in general, so if the condition persists, check that ifmgr is running and that it isn't being blocked by some other process. Also examine any other error messages arising alongside this one.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMDR-6-CHKPT_SERVER_COMMAND ### Response: (Severity: 6), (Category: OS), (Description: Status information while checkpointing the server command issued.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBSOC-3-SVC_ERROR ### Response: (Severity: 3), (Category: OS), (Description: A service API failed and error is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT-4-TEST_ABORTED ### Response: (Severity: 4), (Category: L2), (Description: The test running on the specified interface has been aborted.), (Recommended Action: Depending on the exact reason for the abort, restarting the test may succeed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-5-SC_FILEREAD ### Response: (Severity: 5), (Category: SYSDB), (Description: An error occurred during a read operation from the instruction file.), (Recommended Action: Check that the file format is correct. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ETHER-2-XGXS_DTE_SYNC_POST_RECOVERY_FAILED ### Response: (Severity: 2), (Category: L2), (Description: The PLA MAC xgxs DTE layer went down due to loss of sync or lane alignment. The link could not be recovered so the port was disabled), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE-7-UNLINK_ERROR ### Response: (Severity: 7), (Category: OS), (Description: unlink() system call returned an unexpected error Debug trace buffer initialization failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure RSVP bandwidth on a Cisco IOS XR interface? ### Response: To configure RSVP bandwidth on an interface, use the 'rsvp interface' command followed by 'bandwidth' in interface configuration mode. RP/0/RSP0/CPU0:router(config)#rsvp interface GigabitEthernet0/0/0/0 RP/0/RSP0/CPU0:router(config-rsvp-if)#bandwidth 100000 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEPKI-6-FQDN_CHECK_IPADDRESS_ALLOW ### Response: (Severity: 6), (Category: SECURITY), (Description: 'As per the Cisco's Product Security Baseline, IP address in the common name of X509 certificate should not be used, as IP addresses are considered less secure.'), (Recommended Action: 'Informational, user is enabling backward compatibility by allowing ipaddresses in the CN. Security standards recommend using FQDN. Enabling this cli reverts to old behavior of allowing ipaddr in CN. User should consider moving to FQDN.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-RPC ### Response: (Severity: 3), (Category: ROUTING), (Description: An RPC error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_FPGA-6-INFO ### Response: (Severity: 6), (Category: L2), (Description: This is a informational message from PLIM FPGA driver to indicate an operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-4-TCP_NAGLE ### Response: (Severity: 4), (Category: IP), (Description: Nagle's algorithm was not disabled; there is a small chance the telnet session will appear jerky. Telnet will otherwise function normally.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The router can continue to be used.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO-3-ERR_PAK_FSV_REGISTRATION ### Response: (Severity: 3), (Category: PLATFORM), (Description: Internal Error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-2-INFRA_FAIL ### Response: (Severity: 2), (Category: OS), (Description: There was a ENA infra call failure resulting in a failure to provide some infrastructure service.), (Recommended Action: Restarting lpts_pa may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-DEV_QSFP_OPTICS_PORT_UNSUP ### Response: (Severity: 2), (Category: PLATFORM), (Description: A QSFP+ Module not supported for the port error was detected during QSFP+ initialization. A QSFP+ Module not supported for the port error is reported when Optics is not supported on the port. The QSFP+ is the pluggable optics on the line cards. QSFP+ initialization may happen when linecard boots up, QSFP+ OIR and line card process restart.), (Recommended Action: Verify that the QSFP+ Module is supported for the port. Replace the QSFP+ with a working one (if any) to isolate bad optics. Check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the command 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_CPP_MCAST_GTRIE-3-INIT_FAILURE ### Response: (Severity: 3), (Category: ROUTING), (Description: Error while initializing Gtrie. Initialization failed and aborted), (Recommended Action: Please collect debug multicast-gtrie <> for analysis on the cause If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAL_CGM-3-INIT_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The PAL ACL CGM DLL failed to initialize because of memory alloc failure. This DLL does a generalization of an Access Control List to include matching on MQC match criteria If the ccl DLL fails to initialize, the access control list cannot be programmed into the hardware.), (Recommended Action: The failure should be handled by the process that is loading the DLL. The calling process should retry the initialization.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-EBS_RGMII_FIFO_FULL ### Response: (Severity: 0), (Category: PLATFORM), (Description: EBS RGMII FIFO full.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-0-BOARD_SILAB_CLK_FAIL ### Response: (Severity: 0), (Category: PLATFORM), (Description: Device driver detected a clock failure on some bus/port), (Recommended Action: RMA the LC ,if you see this error on every reload. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-4-NPU_HW_OOR ### Response: (Severity: 4), (Category: ROUTING), (Description: When the NPU (network processor unit) resources for the interface are in yellow or red states, then MPLS-TE will apply the configured actions for the particular state.), (Recommended Action: The operator should monitor the NPU resources and try to bring back the system to the normal resource level by reducing the number of LSPs on this interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_CONF_PRX-4-ERR_SYSDB_EVENT ### Response: (Severity: 4), (Category: SECURITY), (Description: Sysdb subsystem sent a notification after a configuration change. This notification has an configuration change type that is not known to SSH. So, the configuration notification received has not been processed and configuration change applied.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-3-EVM_CREATE ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when creating Event Manager.), (Recommended Action: Collect show tech ssm. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GDOI-0-SVC_EMERG ### Response: (Severity: 0), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSLA-5-LPD_RESULT_CHG ### Response: (Severity: 5), (Category: MGBL), (Description: Result of the LSP Path Discovery has changed for the operation. In case of a failure, the value of the retcode field indicates the cause of the failure. Refer to the Textual Convention RttMplsVpnMonLpdFailureSense at the CISCO-RTTMON-MIB for possible reported causes.), (Recommended Action: When result changes to a value other than 'OK', it means that the ECMP discovery could not be completed successfully for the particular period. When paths are reported as broken or unexplorable, identify the available paths through the 'show ipsla mpls lsp-monitor lpd summary' command and use the 'traceroute mpls' tool to collect more information about the failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-6-RESERVE_AUTH_FAILED ### Response: (Severity: 6), (Category: LICENSE), (Description: None.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-INVAL_REDUNDANCY_ROLE ### Response: (Severity: 3), (Category: ROUTING), (Description: An invalid Redundancy Role was delivered to BGP. If this occured during process startup or RP Switchover, then the process may be restarted.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-OOR_GROUP_RANGE_OK ### Response: (Severity: 4), (Category: ROUTING), (Description: This router has fallen below the maximum value for the number of group ranges allowed to be received through the given group-to-RP mapping distribution mechanism.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-TSPI_ASYNC_FIFO_L72_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: TxSPI async FIFO low 72bits data single bit ECC error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_FGID_REFRESH_RETRY ### Response: (Severity: 3), (Category: FABRIC), (Description: An FGID entry is disabled following a parity error. Request to refresh the entry wasn't entertained. This will reload the fabric card to recover.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ETHER-3-IMDR_ERR ### Response: (Severity: 3), (Category: L2), (Description: Plim asic driver imdr errors. Typically these errors indicate failure in system services during the imdr procedure.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-MISSING_PLANE_CONFIG ### Response: (Severity: 6), (Category: FABRIC), (Description: Missing admin plane configuration for this module.), (Recommended Action: Check the admin plane configuration to ensure that it corresponds with the actual physical topology of the system. If this configuration looks correct then contact support, otherwise correct the configuration and the system should recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-AMBIGUOUS_PASSWD ### Response: (Severity: 3), (Category: SECURITY), (Description: Single digit passwords are not allowed and password should not start with numeral.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_BAD_MAGIC ### Response: (Severity: 4), (Category: L2), (Description: An SSRP keepalive message has been received containing a magic number which is different from expected. This either indicates a problem on the peer router, or indicates that SSRP has somehow begun receiving packets from a different router altogether.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.. Check that the SSRP configuration for the network is correct.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-4-QFP_FAILURE_GIC_BIND ### Response: (Severity: 4), (Category: L2), (Description: Failed to bind to the QFP Generic Interface Client), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers QFPCPUBridge trace <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers QFPCPUBridge trace <> output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSM-4-ANOMALY ### Response: (Severity: 4), (Category: OS), (Description: A SW exception occurred in FSM Library), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-VCPU_LIMIT ### Response: (Severity: 3), (Category: OS), (Description: The virtual service machine definition file is requesting more VCPUs than the system has reserved for virtual services.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-1-HSSD_UNKNOWN ### Response: (Severity: 1), (Category: PKT_INFRA), (Description: This error indicates that a code sanity check has failed. This indicates a new global HSSD area was added to Pakman without adding the appropriate endian transform code to NetIO.), (Recommended Action: NetIO will not start properly until the code is fixed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-XTC_DB_DELETE ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process failed delete sr-policy from xtc_db.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-SPIO ### Response: (Severity: 4), (Category: L2), (Description: PTP MA encountered an error interacting with SPIO. The error message describes what operation has failed and why it failed. The error could also be caused by low memory resources or programming error.), (Recommended Action: Consider restarting the PTP MA process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-DB_INCONSISTENT ### Response: (Severity: 3), (Category: L2), (Description: An internal inconsistency was identified while performing some operation on the database. The process will attempt to recover a consistent state, and should be able to continue operating. It is possible that some parts of CFM may become out of sync.), (Recommended Action: If additional problems are observed then restarting the process may help to restore the system to a consistent state. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-4-OOR_PROT_STOP_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is a warning message in the DNX FIB to indicate that named resource become available and OOR protection for the resource stopped.), (Recommended Action: NONE) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_SFP1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-3-TLV_PARSE_LEN_INCORRECT ### Response: (Severity: 3), (Category: SERVICES), (Description: 'Parsed TLV message length is greater than ' 'original message length'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-BFD_DELETE_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to delete one or more sessions with the BFD server. The connection to the server will be reset in an attempt to recover from the error.), (Recommended Action: This failure may due to lack of resources. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the failure is not due to a lack of resources seek support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-4-SD_BATCH_ERR ### Response: (Severity: 4), (Category: SERVICES), (Description: One or more errors occurred in RSPP MA, the service diversion management agent, during the processing of a set of notifications from Service Director, containing service locations and diversion information. Diversions for service attachments may now be inconsistent on the given node. The error string will give more detail on the type of error that has occurred.), (Recommended Action: If the error is a resource error this will be indicated in the error description given. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem. If the error string given does not indicate that this is a resource error, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR-4-PCDS_ERR ### Response: (Severity: 4), (Category: PLATFORM), (Description: An error occurred inside PCDS data structure. Process continues to run but PCDS data may not be logged properly), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support control ethernet fast location , dumpcore running eth_server location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support control ethernet fast location , dumpcore running eth_server location output, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE0_CODE_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE0_CODE_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-3-LOCKING_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: bfm encountered an error and is not able to recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-4-UNABLE_TO_DELETE_FILE ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: As part of an install operation a file could not be deleted.), (Recommended Action: Delete the file manually.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-7-MSG_CRIT_NORM ### Response: (Severity: 7), (Category: OS), (Description: The bcdl_agent_start api was used incorrectly.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-FIA2NPU_1_PKT_MAXLEN_ERR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet maximum length error on FIA to NPU-1 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_THREAD_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed to create a thread essential to its operation. This is an internal software error. It requires a restart of the isis process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-3-ERR_ADDRESS_FAMILY ### Response: (Severity: 3), (Category: IP), (Description: The telnetd server was passed a bad adress family.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-REQUEST_REJECTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The requested action was not performed.), (Recommended Action: Rety later or configure the node to be out of that state before performing again the same action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-IDB_FREE_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace im error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace im error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-MEPS_DELETE_CCM_GEN ### Response: (Severity: 3), (Category: L2), (Description: The CFM MA tried to delete a number of MEPs whilst some of those MEPs were scheduled to have CCM generation enabled or disabled. The CCM generation batches have been cleared, which may cause an inconsistency between CFM's internal state and the requested configuration.), (Recommended Action: If any problems are observed, then try restarting the CFM Daemon using the 'process restart' command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-4-FROM_MRIB_UPDATE ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_2_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-4-DIR_MODE_ERR ### Response: (Severity: 4), (Category: MGBL), (Description: This message indicates that the directory path specified in the message has incorrect mode (ie. not a directory). As a corrective action, the software attempts to automatically remove the file. A message of 'No Error' for unlink, for example, would indicate that it has successfully removed the file.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-1-GOLDEN_UPGD ### Response: (Severity: 1), (Category: DRIVER), (Description: card_mgr has detected on this PID the backup IOFPGA is not protected, this operation is a one time operation for this PID. During this upgrade cycle a user should strictly refrain from making any config changes or performing any operation on this card. Failure to comply with this request may cause the HW to be unusable or may result in an RMA. Please ensure the FPD upgrade is successful and then perform regular operations on this HW after a reload as stated in the upgrade complete messages.), (Recommended Action: In case the operation fails please collect logs 1. Syslogs 2. show tech card-mgr 3. show tech fpd 4. show tech obfl 5. show tech shelf-mgr 6. show tech ctrace 7. show tech fpd-serv) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_ASIC_FGID_SRAM_BIST_PASS ### Response: (Severity: 3), (Category: FABRIC), (Description: This message is seen when the FGID SRAM BIST is completed without the necessary pass \ bits being set for the identified ASIC. Observed pass bits status and the expected \ status for the ASIC are also captured in the message. The pass status is a 3 bit status \ i.e. one per SRAM. Number of SRAMs depend on the fabric stage and the fabric board as \ specified below: \ S2 Card: 3 SRAMs i.e. SRAM A, SRAM B & SRAM C. \ S2 ASIC on S123 Cards (all LCC flavors): 1 SRAM i.e. SRAM A. \ S3 ASIC on S123 & S13 Cards (all LCC flavors): 2 SRAMs i.e. SRAM A & SRAM B. \ Pass status bit positions: \ SRAM A: bit 2 \ SRAM B: bit 1 \ SRAM C: bit 0.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-3-DUMPIFS_ERR ### Response: (Severity: 3), (Category: INSTALL), (Description: The dumpifs utility reported errors while extracting IFS2 file from bootimage into shared memory), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_APS-6-UPDOWN ### Response: (Severity: 6), (Category: L2), (Description: Debug messages for APS.), (Recommended Action: No Action requirements.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-4-SITE_XTR_RLOC_INCONSISTENCY ### Response: (Severity: 4), (Category: IP), (Description: 'While probing other xTRs in our own site we received a map ' 'reply mapping record listing a different set of locators ' 'than those we have configured in database commands.'), (Recommended Action: 'Issue the show lisp {ipv4 | ipv6} database' ' command on both this xTR and the other ' 'site xTR that sent us the map reply to locate the ' 'mis-configuration. Add or remove locators in the ' 'config of one or both xTRs to make them have the ' 'same list of configured locators.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_SERDES_2_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data serdes link 2 failure on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-ULOOP_USID_LIMIT_EXCEEDED ### Response: (Severity: 6), (Category: ROUTING), (Description: ISIS was unable to provide microloop avoidance for a node or prefix because the platform or linecard does not support the needed number of uSIDs.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_SAAR-2-INIT ### Response: (Severity: 2), (Category: L2), (Description: There was an error initialising the ATM SAAR component. first %s --> Describes the error second %s --> return code string), (Recommended Action: Check memory conditions on the node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-2-HIGH_LASER_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected an SFP laser bias greater than or equal to the high laser bias alarm threshold. The SFP is the pluggable optics on the line cards. The laser bias threshold values are read from the SFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-4-HC_WARNING ### Response: (Severity: 4), (Category: IP), (Description: The ipv6_ma process is blocked for more than 2 Mins on some other process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check process blockage in the router.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_RIB_NOTIFICATION ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS received an unexpected RIB notification pulse and will ignore it.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-6-HEADLESS_CASE_DETECTED ### Response: (Severity: 6), (Category: OS), (Description: Headless case detected recovering though PON.), (Recommended Action: none. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK_LIB-3-DEBUG_SERVICES ### Response: (Severity: 3), (Category: OS), (Description: A call to a debug services interface failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-DISK_FSCK_TIMEOUT ### Response: (Severity: 3), (Category: PLATFORM), (Description: TBD.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-1-CPU_HOG_ALERT ### Response: (Severity: 1), (Category: HA), (Description: This message is displayed after the CPU hog detector trips. It shows the percentage of CPU used by the busiest thread in the top consumer of CPU.), (Recommended Action: The command 'show watchdog trace' will display additional information about the potential CPU hog. If the hog is persistant, contact technical support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFMMIB-3-NO_STACK ### Response: (Severity: 3), (Category: L2), (Description: In the initialization of the DOT1AG/MEF SOAM MIB DLL an error occurred while trying to set up a filtered interface table for stack entry lookups. As such, items in the Dot1agCfmStackEntryTable will not be accessible via SNMP requests.), (Recommended Action: Continue working with the DOT1AG/MEF SOAM MIB DLL without the ability to query the Dot1agCfmStackEntryTable, or restart the mibd_interface process in an attempt to clear the error. If the error message indicates an out of resource condition Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNVGEN-3-AAA_INVALID_TASKID_SIZE ### Response: (Severity: 3), (Category: MGBL), (Description: 'Found invalid/corrupted AAA data'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PM_API_LIB-2-SERVER_DATA_QUEUE_FULL ### Response: (Severity: 2), (Category: ROUTING), (Description: The PM server inter-process message queue is full and further messages cannot be accepted. This may impact PM functionality if the condition persists.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-3-LIB_INVALID_TYPE_FOR_LONGEST_MATCH_ACL ### Response: (Severity: 3), (Category: ROUTING), (Description: Only IP prefix-lists can be used to enable longest-match LSPs.), (Recommended Action: The system proceeds by ignoring the configuration. This will result in longest-match LSPs not being established. Unconfigure the ACL and configure an IP prefix-list instead.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-ALARM ### Response: (Severity: 4), (Category: LICENSE), (Description: The current system opid mismatched with the restoration license opid.), (Recommended Action: Use latest license restore file.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-INSUFFICIENT_MEM ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is a thread in the context of the IOS XR microkernel? ### Response: A thread is a unit of execution within a process. The microkernel schedules threads, not processes. A process can have multiple threads. Threads time-share the CPU and can communicate using synchronous message passing IPC. Context switching between threads is very fast. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMATTR-3-UNKNOWN_PULSE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The attribute client or owner has received a pulse which is not expected, and cannot be handled. This message has been dropped. If no other problems are seen then the error can be considered harmless.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ_MGR-4-WARN_INIT ### Response: (Severity: 4), (Category: FABRIC), (Description: Fabricq manager encountered an error but was able recover or continue execution. This message is just for informational.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LINK-4-BERTSTATUS ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The bert status of the link), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-3-ROLLBACK_FAILURE_DURING_MODIFY ### Response: (Severity: 3), (Category: QOS), (Description: QoS EA encountered an error when modifying the policy on an interface, upon which a rollback was attempted on this interface to restore the old policy. There was an error encountered during this rollback too, due to which neither the old policy nor the new policy is applied in hardware for this interface.), (Recommended Action: Try removing the QoS policy on the interface for which this error message is printed from configuration, and then reattach the policy to the interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-6-L3IF_OOR ### Response: (Severity: 6), (Category: ROUTING), (Description: L3 EM Table OOR during l3if creation event), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_10_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_10 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PVSTAG-3-TIMER_FAILED ### Response: (Severity: 3), (Category: L2), (Description: An error has occurred processing one or more timer events driving the PVRST engine. The process has restarted to correct this issue.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE_ERR_7_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE_ERR_7 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTS3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-SRV6_ENABLE_DISABLE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: ISIS is unable to enable or disable SRv6 The problem may be caused by a low memory condition but is most likely to be an internal programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-CRC_ERR_1_FIA_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: CRC error - 1 from FIA on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_MEMPOOL_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed to create a memory pool. IS-IS cannot operate without this resource and will abort. The most likely cause is a low memory condition.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart IS-IS. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-LOCK_HELD ### Response: (Severity: 7), (Category: OS), (Description: This is a debug message that is not compiled into a customer version of the code.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BUNDLE_AGG_POLICER-6-MODE_CHANGE ### Response: (Severity: 6), (Category: QOS), (Description: Any change in bundle aggregate policer mode requires the LC to be rebooted to or removal and re-apply of the policy to take effect.), (Recommended Action: - Reload of the card or chassis - Or remove the policy and reattach) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_BGP_CONVERGE ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS is configured to set the overload bit in its LSPs upon startup and to wait for BGP to converge before resetting the overload bit, but an error has occurred whilst registering for notification of BGP convergence. As a result, the overload bit will not have been set upon startup. This may be due to a low-memory condition but may also be due to internal programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_MGR-3-PROCAGENT_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FGID driver failed procagent initialzation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-3-NULLREG ### Response: (Severity: 3), (Category: MGBL), (Description: could not find registry entry.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_CLI-3-INTERNAL_PARAMETER ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP CLI Agent has passed itself an invalid parameter - this point in the code should not have been reached. The HTTP process may need restarting if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-2-WARM_BOOT_UPDATE_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: An internal error has occurred in prm_server process which cannot be recovered automatically.), (Recommended Action: Router reload is required to recover the process state.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR_API-3-PAKINPUT_FAILED_MATCH ### Response: (Severity: 3), (Category: PLATFORM), (Description: Input packet hardware queue failed match while trying to return a group of buffman buffers to ES rx/tx mem pool This message indicates that input hardware queue failed to match assigned hardware queue.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMC-7-PROTOCOL ### Response: (Severity: 7), (Category: SYSDB), (Description: There was a mismatch between the messaging protocol version used by the SysDB MC and the SysDB MS.), (Recommended Action: Upgrade all nodes to have the same version of SysDB installed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-5-PORT_CONTROL_ENABLE_SUCCESS ### Response: (Severity: 5), (Category: L2), (Description: Port Control is enabled on the interface.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-EDM_ENCODE_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: CLNS failed encode a bag for EDM.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFLX_LIB_EA-3-ADJACENCY ### Response: (Severity: 3), (Category: SERVICES), (Description: An error was encoutered while trying to set up adjacencny information for a InterFlex interface. The exact error is detailed in the error message. Packets will not be forwarded to the affected interface.), (Recommended Action: It may help to restart the affected InterFlex EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be addressed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_DIAG-6-CE_SWITCH_LPBK_TEST_INFO ### Response: (Severity: 6), (Category: DIAG), (Description: This is the informational message just to inform the difference of time between two consecutive threshold failures for inter or intra rack control ethernet switch loop back test. If its greater than one hour diagnostic software will not reset the node and skip the test.), (Recommended Action: Please mark a note of it and share if needed. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_CLIENT-7-API_ERROR ### Response: (Severity: 7), (Category: HA), (Description: This provides information about non-error conditions which may even be expected under certain circumstances. Nevertheless, these are not considered 'desirable' conditions.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-4-INFO_FAILURE ### Response: (Severity: 4), (Category: SECURITY), (Description: SSH encountered authentication warning.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2C-3-ERR_MISCONFIG ### Response: (Severity: 3), (Category: L2), (Description: The L2VPN Uberverifier has detected a misconfiguration. It was not detected in the verification phase, so the Uberverifier cannot correct this.), (Recommended Action: The misconfiguration can be corrected by deleting all configuration from the specified interface and its subinterfaces, and then reapplying the configuration. If the problem persists, do the following: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-7-ERR_BAG_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: The Fabric driver was unable to register Fabric driver bags. The Fabric driver and the System should continue to function as normal, with the exception that the 'show' commands for Fabric driver will not be available.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-3-INCONSISTENCY_ALARM ### Response: (Severity: 3), (Category: MGBL), (Description: The configuration inconsistency alarm has been raised or cleared.), (Recommended Action: If the configuration inconsistency alarm has been raised, run 'clear configuration inconsistency' to synchronize the persistent configuration with the running configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure MAC learning for an L2VPN bridge domain? ### Response: To configure MAC learning for an L2VPN bridge domain, use the 'mac learning' command within the bridge-domain configuration. l2vpn bridge-domain BD1 mac learning <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-STATS_INIT_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates that stats SHIP register initialization operation has failed. Embedded string provides the information about the error and the failed SHIP register. There is no functional impact as this stats is for debugging purposes only.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-CLOSE_PROBLEM ### Response: (Severity: 7), (Category: OS), (Description: Dumper opens various files, writes the data and closes the files. Possibly the server died. It might have unpredictable behavior of dumper.), (Recommended Action: Please collect the data and contact support. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. follow process 6. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT_SWITCH-3-LINK_FAIL_5 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Punt link failed), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_LTRACE ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the Lightweight Tracing service. The error message describes what operation has failed and why it failed. This is a fatal error and the PPP MA process cannot continue. It will abort and subsequently be restarted by SysMgr in an attempt to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-3-ERR_IM_STATE_REGISTER ### Response: (Severity: 3), (Category: L2), (Description: CDP failed to register with the interface manager for state changes on this particular interface. This means CDP will be unable to track the state of the interface. CDP functionality may be impaired.), (Recommended Action: Perform 'cdp disable', 'cdp enable' on the interface to try to recover. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-INSUFF_ARG ### Response: (Severity: 4), (Category: MGBL), (Description: Invalid Arguement. Null paramater passed as part of sysdb path. Please enter a valid sysdb path.), (Recommended Action: Use the help command to determine the correct usage for this command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_1_EGR_Q_ERR_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Egress queue error on NPU-1 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDEVINFO-3-LWM_ERROR ### Response: (Severity: 3), (Category: MEDIA), (Description: Failed to execute some LWM library functions.), (Recommended Action: restart process 'fs_dev_info' from exec prompt - from exec prompt 'restart process fs_dev_info' if issue persists contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_DLL-5-ERR_ASIC_PARITY ### Response: (Severity: 5), (Category: FABRIC), (Description: In the specified block a parity error encountered at mentioned addr offset. If the error exceeds its threshold, the driver trigger a corrective action which may include device reset or MSC reload.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ct_agent-3-ERR_SYSDB_GET ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-6-NOTIFICATION_EVENT ### Response: (Severity: 6), (Category: L2), (Description: This informational message indicates an event which requires attention), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-CHKPT_INIT ### Response: (Severity: 3), (Category: OS), (Description: An internal Checkpoint function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE2_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE2_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XFP-3-LOW_TEMP_ALARM ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected an XFP temperature less than or equal to the low temperature alarm threshold. The XFP is the pluggable optics on the line cards. The temperature threshold values are read from the XFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the XFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-3-LC_POWER_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This error message indicates that there is a failure to power up LC card.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_PORT_ERRNO ### Response: (Severity: 3), (Category: SECURITY), (Description: Error description, error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-4-TO_MRIB_MOFRR_UPDATE ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BOOTVAR-7-VAR_TOO_BIG ### Response: (Severity: 7), (Category: INSTALL), (Description: Boot variable has exceeded the maximum size.), (Recommended Action: Reduce size of boot variable by removing unwanted inactive SMUs and packages. For e.g., remove extra boot system commands, and try again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TSEC-4-DRIVER_ERROR_BUFALIGN ### Response: (Severity: 4), (Category: PLATFORM), (Description: A packet buffer passed to driver is not aligned to required boundary. This is not a critical failure and corrected by driver. Driver can continue function.), (Recommended Action: If happens entensively, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_EA-3-PLAT_UPD_FAILED_GL ### Response: (Severity: 3), (Category: L2), (Description: Platform update failed for all interfaces in a batch.), (Recommended Action: restarting ipv6_ea may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-AF_LIB_FILE_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: 'File/Directory open operation failed, or the data in the file was corrupt'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-VS_NOTIF ### Response: (Severity: 3), (Category: OS), (Description: Unknown vs notif from sysdb.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support sysdb command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support sysdb output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-6-TUNNEL ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: A VPDN session has been terminated due to errors encountered by the L2TP tunnel that contains the affected session), (Recommended Action: The log indicates that a session is terminated or has failed to establish due to teardown of the tunnel that contains it. Please examine the human-readable error message that appears in the log and conduct the first level of troubleshooting based on the info in the message. If the root cause is still not clear, collect the required info and forward it to customer support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTNSEC-2-IKE_SESSION_DELETED ### Response: (Severity: 2), (Category: SECURITY), (Description: Otnsec session is secured), (Recommended Action: No action required (Normal Operation).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ether_spa_mac_error-1-RECOVERY_FAILED ### Response: (Severity: 1), (Category: L2), (Description: A MAC Frame Corruption occurred on the interface, concerned port is in error condition after maximum recovery retries. The concerned port has been permanently disabled. Manual intervention required to re-enable the port.), (Recommended Action: MAC Frame Corruption has occured. Try below steps: 1. Try shut/no shut of the interface. 2. Remove and re-insert the transceiver on the same port. 3. Remove and re-insert the transceiver on a different port. 4. Remove and insert the transceiver on different spa. If the issue still persists collect the output of below CLIs and contact TAC. 1. 'show inventory' 2. 'show controllers ' 3. 'show logging') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-3-NULL_EVM ### Response: (Severity: 3), (Category: L2), (Description: Event manager not created), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSUDIR-5-OPERATION_ISSU_ABORT_DONE_WITH_CLEANUP ### Response: (Severity: 5), (Category: INSTALL), (Description: The ISSU has successfully executed its abort procedure and will now begin to restore the system to a consistent state.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_7_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_7 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_MAP-3-IM_RELATED_FAILURE ### Response: (Severity: 3), (Category: ROUTING), (Description: Failed some IM related operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp mapping-agent trace interface activities command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp mapping-agent trace interface activities output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp mapping-agent trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp mapping-agent trace output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the Configuration Manager in IOS XR? ### Response: The Configuration Manager in IOS XR is responsible for processing configuration commands entered by the user, validating the commands, and applying the configuration to the relevant processes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-3-CLIENT_LOCK_ISSUE ### Response: (Severity: 3), (Category: OS), (Description: 'Failed in locking the GSP client. '), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-3-ENQUEUE_FAIL ### Response: (Severity: 3), (Category: DIAG), (Description: An internal software error occurred while processing the diagnostic message alongwith the opcode to the dignostic process of the specified card or location/sub-location.), (Recommended Action: Copy the error message exactly as it appears on the screen and gather the output of show tech-support and any other relevant information. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: S2681-3-IO_PERM_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The S2681 UART driver has been unable to gain the required permissions to access the UART.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACLMIB-7-INIT_DEBUG ### Response: (Severity: 7), (Category: ACL), (Description: The ACL MIB library initialization has failed. The ACL Statistics MIB functionality will be still be available, but some of its functionality not be completely available. You may not be able to turn on debugs, get ltrace, ship logs, or some other minor functionality.), (Recommended Action: Check the error string and try to restart the mibd_interface process with the command process restart mibd_interface If this does not correct the problem, collect the required information listed below.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PM-5-CHKPT ### Response: (Severity: 5), (Category: MGBL), (Description: An error has occurred while doing a checkpointing operation. This may result in loss of old statistics data during process restart.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-3-GEN_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error in PCIE Operation), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-EVM_TM_LEAF_NEW ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to create a timer tree leaf object.When this issue happens, it will trigger an automatic restart of pifibm_server_lc process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-2-MOBILE_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The Sync-E is configured without the necessary mobile license.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-UNEXPECTED_HB ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that a HB was received from a node that was not previously detected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_7_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_7 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-4-EXITING ### Response: (Severity: 4), (Category: SECURITY), (Description: A failure occurred during shutdown of the specified process, and it was unable to notify the System Manager that it was about to exit. In rare cases, this could result in a failure by the System Manager to restart the process when it ought to do so.), (Recommended Action: If the process ought to be running and is not, then attempt to restart it using the 'process restart' command. If this fails, deconfigure the process and re-enter the configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-MISS_EOP_0_FIADDR_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Missing EOP-0 from FIA DDR on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDLD-4-DETECTION_DISABLED ### Response: (Severity: 4), (Category: PLATFORM), (Description: Detection disabled means either UDLD gets disabled, or UDLD is running but the port gets disabled, or detects a link down or the module is reset.), (Recommended Action: Check the link on which the error happenned. Try replacing/reconnecting the GBIC/SFP/cable at either end of the link. Re-enable the port on the RP and see if the port comes up. If the problem still exists the port will be disabled again with this message. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND-3-ERR_INVALID_RA_INTERVAL_FOR_CONFIGURED_DNS_LIFETIME ### Response: (Severity: 3), (Category: IP), (Description: This configuartion for the maximum Router Advertisement (RA) interval will make already configured RA DNS Lifetime invalid.Configuration range of RA DNS Lifetime is dependent on the maximum Router Advertisement (RA) interval. RA DNS Lifetime should be greater than maximum Router Advertisement (RA) interval and less than twice the value of maximum Router Advertisement (RA) interval.), (Recommended Action: First remove the configuration of the DNS server or DNS search list , which will become invalid due to this maximum Router Advertisement (RA) interval configuartion. second , configure this maximum Router Advertisement (RA) interval configuartion. third , configure DNS server or DNS search list , which we removed in first step.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-INSTALL_PKG_SHOW_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Install manager might have died), (Recommended Action: Verify if install manager is up and running.No action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-CARD_YELLOW_OVERTEMP_CONFIG_CLEAR ### Response: (Severity: 4), (Category: PLATFORM), (Description: Yellow threshold unconfigured. Clearing yellow alarm.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NCS4K_4H_OPW_QC2-4-UNKNOWN_LASER_STATE ### Response: (Severity: 4), (Category: PLATFORM), (Description: Some devices (DENALI, CFP2) cannot be upgraded in field if the CFP2 laser is ON. Download of these binaries is not reliable with laser ON. Download is prevented if the laser state information is not available.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPPIF-4-WARN ### Response: (Severity: 4), (Category: PLATFORM), (Description: A run time warning occurred during the pidb operation on the linecard. The reason for the error is dispalyed. Please call Cisco Support with the error information), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does IOS XR manage configuration during package activation and deactivation? ### Response: During package activation in IOS XR, any new configuration options introduced by the package become available. During package deactivation, the configuration related to the package is automatically removed to ensure consistency. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-NBREXIST ### Response: (Severity: 4), (Category: ROUTING), (Description: Neighbors had been configured earlier when the network type was nonbroadcast. The current configuration request will cause these configured neighbors to be abandoned.), (Recommended Action: Remove the configured neighbors.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IDB_LIB-3-ERR_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error information during improper updation of variables or incorrect return state in platform FIB), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE_ERR_6_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE_ERR_6 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-2-PEC_FAILDONE ### Response: (Severity: 2), (Category: PLATFORM), (Description: The inserted expansion card is in failed state due to some reason. LC Recovery required to re-enable.), (Recommended Action: An attempt to initialize PEC failed. Re-Enable/Power-on the card only if we have sufficient power. Please try to recover by reloading line card using CLI 'hw-mod loc <> reload'. If the issue persists, collect console log and the following information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - sh platform - sh install summary - sh version - show tech-support ethernet interfaces - gather) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-2-PHY_XAUI_THRESH ### Response: (Severity: 2), (Category: L2), (Description: The XAUI bus between the PLA ASIC and PHY device experienced a synchronization problem resulting in a lane failure causing a link flap. Software could not recover the problem and the port has been disabled.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-3-ADJ_WARNING ### Response: (Severity: 3), (Category: L2), (Description: A runtime error occurred in ASR9K adjiacency module. The reason for the failure is also displayed. Please call Cisco Support with the error information.), (Recommended Action: Please collect the console log and following traces: show cef trace loc show cef platform trace [common|ipv4] all loc show adjacency hardware trace loc show bundle trace all loc show im trace loc Most of the time, these are harmless transient messages, caused by the delay in FIB and AIB processes learning about new interface. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAN_SWITCH-2-LINK_FAULT ### Response: (Severity: 2), (Category: PLATFORM), (Description: The internal link interface for the specified port is down.), (Recommended Action: Gather the data listed in 'required_info'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_CONFIG-7-ERR_MUTEX_UNLOCK ### Response: (Severity: 7), (Category: OS), (Description: A internal mutex operation has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_SSL-6-CERT_VERIFY_INFO ### Response: (Severity: 6), (Category: SECURITY), (Description: SSL general info message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-3-STARTUP ### Response: (Severity: 3), (Category: MGBL), (Description: Configuration Manager is displaying an error message during boot time.), (Recommended Action: Most likely the error has caused some kind of configuration loss that is not saved as failed configuration. Check running configuration and any reported failed startup configuration. Manually reapply any missing running configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-4-PFI_ERROR ### Response: (Severity: 4), (Category: L2), (Description: Unexpected updates have been received by the Ethernet Link OAM Daemon regarding interfaces on which OAM is not configured. This indicates that a resync is required between the OAM process and PFI.), (Recommended Action: Restart the Ethernet Link OAM Daemon on the affected node. This will force a resync of the state with PFI. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-6-EOBC_LINK_DOWN_CLEARED ### Response: (Severity: 6), (Category: PLATFORM), (Description: A link on epm switch device was down, but now cleared), (Recommended Action: 'show controllers epm-switch port-mapping location *') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-EXTERNALERR_RC ### Response: (Severity: 3), (Category: ROUTING), (Description: An external software error occurred. This is a non-OSPFv3 errors triggered from external DLLS, libraries, or inter-process calls.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-6-INIT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is to print process initialisation messages.), (Recommended Action: No info needs to be collected. This is an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_METRO-3-QINQ_INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: L2FIB Metro L3QinQ failed to initialize correctly. Without L2FIB Metro L3QinQ init, can not configure L3QinQ vlan subinterfaces.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED_LIB-7-VECTOR_OVERFLOW ### Response: (Severity: 7), (Category: OS), (Description: A client was unable to send a message to PlaceD due to encountering an internal error condition.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-SI5347_ACCESS_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: SI5347 read/write access failure/success), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-L2FIB_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The L2FIB Infrastructure reported an error which could not be handled. The operation will not be retried - the internal state of CFM may not match the global system state.), (Recommended Action: If any problems are observed, then check the status of the l2fib and l2vpn processes for any obvious errors. If necessary, try restarting the process that encountered the error using the 'process restart' command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY_DB-3-LOCK_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: A system call for locking read-write lock failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP_VRF-3-RD_PUBLISH ### Response: (Severity: 3), (Category: ROUTING), (Description: The RD value for a VRF or set of VRFs failed to be published.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_LOSS_OF_LOCK_EXT ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-GET_ENVPATH ### Response: (Severity: 3), (Category: MGBL), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-5-SC_READERINIT ### Response: (Severity: 5), (Category: SYSDB), (Description: An error occurred while preparing to read instructions from the command line.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-6-ALARM_CHANGE ### Response: (Severity: 6), (Category: OS), (Description: Service alarm changes. They are not necessarily critical errors but need investigation by DE), (Recommended Action: Collect system logs. Collect show tech ssm. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABMGR-2-FABRIC_ASIC_FAULT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric asic is down.), (Recommended Action: Fabric asic is down. Recovery action would be taken. If the error is persistent, contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-4-FILE_OPEN_FAIL ### Response: (Severity: 4), (Category: INSTALL), (Description: Failed to open the specified required file, so processing of the current request or operation will halt. The filesystem may be in error, or the Install infrastructure may be behaving incorrectly.), (Recommended Action: Please check the filesystem for corruption using the fsck disk check CLI and retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-5-BD_STATE_CHANGED ### Response: (Severity: 5), (Category: L2), (Description: The state of specified BD, with the BD ID, has been changed. The possible states are: - up - down - admin down The trigger of the BD state change are: - Shut/No Shut BD from CLI - BD operational state changed), (Recommended Action: None. To suppress this IOS message, please unconfig 'l2vpn logging bridge-domain'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-FGID_RETURN_TO_POOL_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while returning FGID back to FGID pool. - invalid FGID passed - FGID lookup fails - space problem with FGID pool), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS_MODULE-2-DEV_OPTICS_BAY_PID_NOT_SUPPORTED ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PID not supported error was detected during optics initialization. A PID not support error is reported when either the PID can not be read or not supported on the platform. The optics is the pluggable optics on the line cards.Optics initialization may happen when linecard boots up, optics OIR and line card process restart. The optics will not be enabled if a PID not supported error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the optics with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-LIST_ITEM_NOT_FOUND ### Response: (Severity: 7), (Category: INSTALL), (Description: An invalid parameter has been unexpectedly passed to the Install infrastructure. This is a coding error. The current request or operation will not be completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-6-MPLS_LABEL_PATHS_EXCEED ### Response: (Severity: 6), (Category: ROUTING), (Description: Controller and/or agent programmed a ELSPs with path count exceeding system limit.), (Recommended Action: Controller and/or agent must ensure that total number of paths across all ELSPs on the label does not exceed system limit. If this error is seen during a mark and sweep operation, Service-layer state may get recovered when stale objects are removed when controller and/or agent send a MPLS EOF message. Use Service-layer show commands to confirm if the total number of paths on the label exceed system limit.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_AGORA_ALM_TYPE_TWO ### Response: (Severity: 2), (Category: PLATFORM), (Description: AGORA type two alarm.), (Recommended Action: If the problem persists, call your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-REP_COM_REMOVE_NOT_TRIGGERED ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that the auto commit operation failed, hence install remove inactive all will not be triggered.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_LOL_MAPPERC ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an IPv4 address on an interface? ### Response: To configure an IPv4 address on an interface in Cisco IOS XR, use the 'ipv4 address' command in interface configuration mode. RP/0/RP0/CPU0:router(config)#interface GigabitEthernet0/0/0/0 RP/0/RP0/CPU0:router(config-if)#ipv4 address 192.168.1.1 255.255.255.0 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-2-CPU_PRT_D_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Interrupt controller driver detected a data parity error from the cpu), (Recommended Action: Please try to correct the problem by reloading the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install verify packages command in IOS XR? ### Response: The 'install verify packages' command is used to verify the consistency and integrity of the currently active software packages on the router. It checks for any missing or corrupted files. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_16P_OC48-3-DEVICE_INTR_DISABLE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The specified device is generating excessive interrupts. This message indicates that we are rate limiting the interrupt coming from this device. This indicates a potential HW issue, traffic forwarding (protection switching) may be impacted.), (Recommended Action: Check the fiber or the peer connection. If the problem persist after checking fiber and peer router, please contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-INTF_SESSION_DOWN ### Response: (Severity: 6), (Category: L2), (Description: The OAM session has ended. Either it has been deconfigured, or no response has been received from the OAM peer in the configured time interval.), (Recommended Action: Check that the remote peer is correctly configured still. If it is, then a large number of packets may be being dropped on the link.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-MIB_DLL_ERROR ### Response: (Severity: 4), (Category: L2), (Description: An error was encountered in the PTP MIB DLL. Some functionality of the PTP DLL may be impaired. The error message contains details about the source of the error.), (Recommended Action: It is unlikely that this condition will recover automatically, restarting the snmpd_infra process may be required. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-1-RX_MACRO_SPEED_MISMATCH ### Response: (Severity: 1), (Category: FABRIC), (Description: Unexpected macro type value read from ASIC. There could be a h/w or FPGA issue.), (Recommended Action: Collect all the event logs and 'sh controller fabric trace driver all location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_1_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Tx power greater than or equal to the high Tx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Tx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Replace the QSFP+ with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCMD-3-DUP_INST_ID ### Response: (Severity: 3), (Category: ROUTING), (Description: This indicates that RCMD has detected a duplicate instance of the protocol that it is monitoring. It is a very rare condition arising out of a race condition and can affect RCMD feature working.), (Recommended Action: This will affect the RCMD monitoring for the reported protocol instance. Workaround is to restart the reported routing protocol instance. Report to Technical Support for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-2-PLIM_GENERATION_INCORRECT ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message indicates that this is invalid PLIM and this PLIM is not suitable with present MSC.), (Recommended Action: Replace PLIM with correct generation PLIM) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_ERRORS-7-ERR_ECM_REG ### Response: (Severity: 7), (Category: L2), (Description: ASIC Error library encountered an error while setting up a SYSDB notofication handler with the event connection manager.), (Recommended Action: An error would be reported to the client application which should handle this condition appropriately. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-UNLINK_FILE ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the Package infrastructure is behaving incorrectly. A file involved in the current request or operation could not be unlinked. This may impact install infrastructure functioning.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_LIB-7-DEBUG_CLEANUP ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when cleaning up debug.), (Recommended Action: This is not a critical error message and it can be ignored.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-2-FATAL ### Response: (Severity: 2), (Category: PLATFORM), (Description: A fatal error was encountered, and the program exited. A separate thread is created to handle 'fpd upgrade'. If this pthread_create fails, we are posting this CRITICAL error. This might be a rare situation.), (Recommended Action: If the problem occurs, try to issue 'upgrade fpd' again and see the problem goes away. If problem persists reboot the router or LC either manually or via Command line if the router or LC. If that too fails call Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPA_8P_GE-2-SPA_MAC_ERR ### Response: (Severity: 2), (Category: L2), (Description: The internal SPA MAC got out of sync. SW needs to reset the device in order to clear the issue), (Recommended Action: If reseting the MAC device fixes the issue, nothing needs to be done. If the reset does not work, the SPA will need to be SW OIR'd. This can be easily checked by doing 'top' on the LC with the issue. If the CPU is very high, the reset did not work.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_MPLS_EA-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: SSE MPLS-EA, Debug information), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_9_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_9 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_AGG-3-ERR_GSP ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID Aggregator was unable to create/join GSP group. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-2-CDR_HEALTH_MONITOR ### Response: (Severity: 2), (Category: FABRIC), (Description: Driver monitors the ASIC every 25 seconds to look for any CDR Health monitor check fail, possibly due to CDR Reset or CDR misconfiguration.If an error is reported momentarily, it could be a false positive seen during a transient state. In case, the error is seen repeatedly, please take concerned action.), (Recommended Action: Shut/unshut the link. If it doesn't recover, Reload the card) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_EDM-6-BAGREG_FAILED ### Response: (Severity: 6), (Category: ROUTING), (Description: The process failed while attempting to register its external data manager data blocks with SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-4-DEFAULT_ACTION_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: During the processing of a software change notice, the command to take the default restart action failed. The routine will now fall back on a straight exit.), (Recommended Action: Check the install logs if all the packages are downloaded and install operations completed properly Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_SW-3-ERR_MEDIA_REGISTER ### Response: (Severity: 3), (Category: IP), (Description: netio media register or callback error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-3-LOCK_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: An internal Lock/Unlock operation has failed in the RDS library. While trying to acquire/free a lock in RDS Library , an error condition was returned.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-3-PCI_LINK_DOWN ### Response: (Severity: 3), (Category: PLATFORM), (Description: PCIe interface encountered link down error for the device.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_8_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_8 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-NO_RESP_FROM_RMF_SVR ### Response: (Severity: 3), (Category: OS), (Description: Error in receiving response from rmf svr.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support sysmgr/processmgr command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support sysmgr/processmgr output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_8_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_FPOE_DB_CORR_ECC_ERROR_LNK0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast FPOE correctable ECC error on link 0), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-WRONG_PLATFORM ### Response: (Severity: 3), (Category: DRIVER), (Description: The image loaded on the hardware is not correct, verify the hardware platform and image name.), (Recommended Action: Check for the right image to be used.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-2-ADV_IP_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The VRF feature is configured without the necessary Adv-IP license.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-INSTORCH_STATE_SAVE_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: Install saves its state to disk so that the state can persist over install process restart. An error occurred attempting to save this state to disk. The only recovery mechanism is to restart the install process.), (Recommended Action: This issue can arise when there is not enough space on disk to save the state. To clear disk space remove unnecessary files from the root filesystem of the node(s) in question. If any RPs have insufficient disk space, unnecessary rollback points may be removed using 'clear install rollback id '. After clearing disk space you can retry the operation. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-GRE_KEY_OPTION_NOT_REQUIRED ### Response: (Severity: 3), (Category: IP), (Description: LMA received PBU message with GRE key option. However it expects a non-GRE encapsulation on the tunnel to the peer MAG from which it received the PBU.), (Recommended Action: Note the CoA address and IMSI (if available) from the error message. Run the following commands on the MAG that corresponds to the above CoA address or IMSI. Copy the error message exactly as it appears on the console or in the system log. Issue the show running-config | section mobile command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show running-config | section mobile output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show ipv6 mobile pmipv6 mag globals command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show ipv6 mobile pmipv6 mag globals output, call your Cisco technical support representative and provide the representative with the gathered information. Note the tunnel encapsulation type for this LMA from the output of the above commands. Run the following commands on the LMA. Copy the error message exactly as it appears on the console or in the system log. Issue the show running-config ipv6 mobile command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show running-config ipv6 mobile output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show ipv6 mobile pmipv6 lma globals command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show ipv6 mobile pmipv6 lma globals output, call your Cisco technical support representative and provide the representative with the gathered information. Note the tunnel encapsulation type for the above peering MAG from the output of above commands. Change the configuration on the MAG and or LMA to match tunnel encapsulation. If the tunnel encapsulation on both the MAG and the LMA is already GRE, then change the configuration on the MAG to not insert GRE key option in the PBU. If the issue persists, do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-LOWMEM_RESET ### Response: (Severity: 5), (Category: ROUTING), (Description: A SEVERE low memory condition has been encountered on the node where the BGP process is running, and so to free some memory, BGP has reset a neighbor. BGP will continue to reset neighbors periodically until the low memory condition abates. The neighbors which are reset will be shut down until a 'clear bgp' command is used to bring them back up. They will not come up automatically when the low memory condition abates - this is to prevent the node oscillating between memory states.), (Recommended Action: Free some memory on the system or correct the condition causing the low memory problem, and then use the 'clear bgp
' command to re-enable the neighbors that have been shut down. The 'show bgp all all summary' command can be used to easily see which neighbors are affected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLDP-5-BRANCH_DELETE ### Response: (Severity: 5), (Category: ROUTING), (Description: A mLDP branch has been deleted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-PHASE2_NON_FATAL ### Response: (Severity: 3), (Category: MGBL), (Description: The TTY Server has failed to complete phase 2 initialization. For this instance of the server the failure is not fatal; some services are still available, in particular if the aux port is running ksh then this should still be running unimpacted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-PLL_CLK_EXTERNAL_FAILED ### Response: (Severity: 3), (Category: OS), (Description: External Pll clock lock failed.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-PKT_LEN_ERR_1_XAUI_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet length error - 1 from XAUI on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_IPV4_EA-5-DEBUG ### Response: (Severity: 5), (Category: PLATFORM), (Description: SSE IPV4-EA, Debug information), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-5-VPWS_SEAMLESS_INTEGRATION_STATE_CHANGE ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-INTERNAL_REMOVE_OPERATION_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: Internal install remove inactive operation failed during config remove. This is a recoverable issue but might cause space crunch later when new packages are added.), (Recommended Action: The reason for this install operation failure has to be analyzed. Collect the show tech logs by running 'show tech-support install' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-6-FETCHING_COMPLETED ### Response: (Severity: 6), (Category: INFRA), (Description: ZTP has successfully fetched the provisioning file from the server. ZTP proceed with provisioning.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-5-SECURITY_DAI_VIOLATION_AC ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_EVM_CONNECTION ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB encountered an error while attempting to connect for event notification from event manager. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-4-RESERVE_IN_PROGRESS ### Response: (Severity: 4), (Category: LICENSE), (Description: None.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DAPS-6-POOL_BLK_TRP_DONE ### Response: (Severity: 6), (Category: IP), (Description: All Ip addresses belongs to the blocked pool is now release. This range in now available to be asinged to a new pool. TRAP is genaretd to indicate the same to remote Management Servers.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rlogin-3-ERR_FORK ### Response: (Severity: 3), (Category: IP), (Description: Internal error in forking child process.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIER-0-PCIE_FATAL_ACCESS_ERR ### Response: (Severity: 0), (Category: PLATFORM), (Description: A PCIE access error was detected for controller Card. The error prevents this card to perform some vital tasks making it unusable), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-ENV ### Response: (Severity: 3), (Category: MGBL), (Description: 'Could not update environment variables due to the error'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-4-NULL_FINT_IDB ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_IR1_INTR_FIFO_URUN_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_IR1_INTR_FIFO_URUN interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR-3-LTRACE_INIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ltrace initialization failed. This may be a program level error. The failure will cause the Procmgr process to restart.), (Recommended Action: The Procmgr process will automatically respawn up to a fixed number of times. Verify the process is running: 'show process procmgr location <>' If it is still not spawned contact support with the required info. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEPKI-6-ERR ### Response: (Severity: 6), (Category: SECURITY), (Description: CEPKI general error message with one prameter.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel mesh feature? ### Response: The MPLS TE auto-tunnel mesh feature enables the automatic creation of a full mesh of MPLS TE tunnels between a set of routers. It greatly simplifies the provisioning of TE tunnels in a full mesh topology. Auto-tunnels are created between each pair of routers in the specified mesh group. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: flash_platform-3-OPEN_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: We will perform the stale byte check on: * - SP cards * - if the device is '/bootflash/' If the platform unable to open the device to perfom stale byte check ,then above error message will occur.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSUDIR-1-OPERATION_ISSU_DONE ### Response: (Severity: 1), (Category: INSTALL), (Description: The entire ISSU operation has completed successfully.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IRM_CHKPT-7-INIT_ERROR ### Response: (Severity: 7), (Category: HA), (Description: An error was encountered during intialization of the checkpoint library. The message should indicate the error condition. This is most likely due to a coding error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-MDR_REINITIATE_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'MDR initiate call again after MDR shutdown start.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists.' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the two main components of configuration management in IOS XR? ### Response: The two main components of configuration management in IOS XR are control plane configuration management and data plane configuration management. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How is the OSPF router ID determined? ### Response: The OSPF router ID is determined in this order: 1) Explicitly configured router ID, 2) Highest IP address of any loopback interface, 3) Highest IP address of any physical interface. It is best practice to configure a loopback and set the router ID manually for stability. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RGMGR-4-ERR_RIB_BATCH_SEND ### Response: (Severity: 4), (Category: INFRA), (Description: Redundancy Group Manager encountered an unexpected error while sending a batch of FRR updates to the RIB. This may be a resource starvation problem, or a problem with RGMGR's connection to the RIB, or an internal programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart the RGMGR process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-CARD_POST_IMAGE_NOT_AVAILABLE ### Response: (Severity: 4), (Category: PLATFORM), (Description: The check of the IFD diagnostic image returned failure as the PIE is not installed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE4_CODE_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE4_CODE_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IP_EA-3-ERROR2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IP EA. Here is a list of possible reasons for this message (not all-inclusive). - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Resource limitations. This condiation indicates a problem where the software has limited resources to operate on.), (Recommended Action: Please collect the console log and the CLI output. show cef show memory summary show cef location <> show memory location <> show cef trace location <> show cef platform trace common all location <> show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install activate auto-abort-timer command in IOS XR? ### Response: The 'install activate auto-abort-timer' command is used to set a timer for the automatic rollback of an installation if the user doesn't commit the changes within the specified time. This provides a safety mechanism to revert to the previous software set if something goes wrong during the installation. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-INTF_CREATE_FAIL ### Response: (Severity: 3), (Category: QOS), (Description: QMgr encountered an error during the allocation of queueing resources within a queuing asic as part of interface create.), (Recommended Action: Interface create failed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-6-READ_SHM_ENCAP ### Response: (Severity: 6), (Category: L2), (Description: Debug Information - Displaying Encapsulation, shim and flag for the requested handle), (Recommended Action: No action is required..Informational message only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCI_HAL_SATORI-7-DMAC_INFO ### Response: (Severity: 7), (Category: PLATFORM), (Description: %s- debug info.), (Recommended Action: debug info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-ADJCHANGE ### Response: (Severity: 5), (Category: ROUTING), (Description: A BGP neighbor has either come up or gone down. This message appears only if the bgp log neighbor changes command is configured for the BGP process.), (Recommended Action: This informational message normally appears as routers and BGP neighbors go up or down. However, unexpected neighbor loss might indicate high error rates or high packet loss in the network and should be investigated.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_PERF_DATA_POOL_EXHAUSTED ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-CONFIG_ENQUE_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Config out of sequence message enque failed.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-4-BENCH_MODE_DETECTED ### Response: (Severity: 4), (Category: DRIVER), (Description: The BENCH MODE is used for debugging the card out of the chassis, the jumper or DIP switch to enable this feature should not be set if the card is being inserted in the chassis.), (Recommended Action: Remove the setting before inserting the card back to the chassis.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWRMON-1-CHASSIS_ID_MISMATCH ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'V2 or newer power module in a chassis with a backplane IDPROM configured for V1 modules'), (Recommended Action: 'Reprogram the chassis backplane IDPROM, or replace the power module') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_BRIDGING-7-TCAM_CHUNK_MAX_MAC_LIMIT_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Maximum allowed MAC entry count is reached in the TCAM MAC chunk), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-6-CHKPT_RESTORE_ERR ### Response: (Severity: 6), (Category: SECURITY), (Description: The checkpoited data entry is corrupted as clean flag id was not valid for this entry.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_ECD-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, error information), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_LIB_COMMS-3-SYSTEM_ERROR ### Response: (Severity: 3), (Category: HA), (Description: A call to a system function failed with the specified error code.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-4-MACSEC_CIPHER_MISMATCH ### Response: (Severity: 4), (Category: L2), (Description: Higher strength Macsec Cipher(GCM-AES-256/GCM-AES-XPN-256) is configured than the MKA cipher(AES-CMAC-128) This is not recommended from a security purpose .), (Recommended Action: Review the MKA cipher(AES-CMAC) config and the macsec cipher(GCM-AES) config and ensure that the MKA cipher is either of the same or higher strength than macsec cipher .) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_NI_INTR_CRC_ERR0_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_NI_INTR_CRC_ERR0 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-4-FAILED_SYSDB_CONNECT ### Response: (Severity: 4), (Category: INSTALL), (Description: Insthelper was unable to connect to local sysdb, insthelper will retry), (Recommended Action: This error will be recovered automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XBAR_CLIENT-3-GEN_ERR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates an error condition in client library api while communicating with the server process. It may be caused due to invalid api arguments by client process or a transient condition while the server process is initializing the ASIC), (Recommended Action: This message may indicate a transient condition while the card is booting up. Please check if the error message is seen continuously even after the card has reached IOS-XR RUN state. And if so, then try to power cycle the card. If the message is seen in every power cycle after the card is in IOS XR RUN state then please contact tech-support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-EVM_TM_ATTACH ### Response: (Severity: 3), (Category: HA), (Description: An internal error was detected when trying to allocate a managed timer identifier and assign to it an event handler.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_FPGA-3-ERR_HW_HARD_THRESHOLD_RESET ### Response: (Severity: 3), (Category: L2), (Description: A hardware error reached threshold on the Datapath FPGA. Software will take action as described in the error message to try to recover from the error. The hardware error and the software recovery action will cause hard reset of a device in the data path and will impact traffic. Device: %s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Software action: %s - the action that software will take to try to recover from the error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure a multicast routing instance? ### Response: To configure a multicast routing instance, use the 'multicast-routing' command in global configuration mode. RP/0/RP0/CPU0:router(config)#multicast-routing address-family ipv4 RP/0/RP0/CPU0:router(config-mcast)#interface GigabitEthernet0/0/0/0 RP/0/RP0/CPU0:router(config-mcast-if)#enable <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-QCR_TL_MEM_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected QCR Tail memory error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOMAIN_SERVICES-3-REGISTER_EVM ### Response: (Severity: 3), (Category: IP), (Description: The domain_services process failed to register its verification and apply handlers for SysDB events. Such errors are not expected and should go away with process restart domain_services.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMC-7-INVALID_PATH ### Response: (Severity: 7), (Category: SYSDB), (Description: An operation has been attempted on a part of the SysDB namespace that should not be used.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHOWCMD-3-VALIDATE_LENGTH ### Response: (Severity: 3), (Category: SNMP), (Description: 'The failure pertains to show commands in snmp to validating the data length ' 'This does not indicate feature failures or issues'), (Recommended Action: 'This log does not indicate a system impact.' 'all show snmp CLI's for debugging purpose only' 'Recommend customer to re-try the command.' 'If there is no output, reconfigure the snmp settings and re-try') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFEA_IPV4_EA-3-CRITICAL ### Response: (Severity: 3), (Category: PLATFORM), (Description: AFEA IPV4-EA, Critical error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: S2681-3-COND_SIGNAL_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The S2681 UART driver was unable to signal that that status variable was ready to be read.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the configuration rollback feature in IOS XR? ### Response: The configuration rollback feature in IOS XR allows you to revert the configuration to a previously committed state. This is useful for quickly recovering from configuration errors or rolling back to a known good configuration. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VASI_EA-3-NOT_FOUND ### Response: (Severity: 3), (Category: SERVICES), (Description: The VASI EA process received a request to process an interface that does not exist in its database. This indicates some sort of internal inconsistency.), (Recommended Action: It may help to restart the VASI EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-gsp_msg_failed ### Response: (Severity: 3), (Category: OS), (Description: The internal communication channel among pctl threads is broken.), (Recommended Action: Must restart the process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOADPATH-7-CORRUPT_ARG ### Response: (Severity: 7), (Category: INSTALL), (Description: Value of a parameter passed to function appears to be corrupt. The current request or operation will not be carried out.), (Recommended Action: Try to re-acquire the pie files from the cisco respository referred to you. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_UV-3-ERR_SYSDB_DISCONNECT ### Response: (Severity: 3), (Category: ROUTING), (Description: The ospf_uv process was unable to unbind from SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_3_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-QUERY_PEERS_TIMED_OUT ### Response: (Severity: 7), (Category: OS), (Description: Ticket request timed out.), (Recommended Action: This is a Debug message. No action required. If problem persists,contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-GET_PROCINFO_FAILED ### Response: (Severity: 6), (Category: OS), (Description: Dumper collects all the process related data by using system call devctl. If a devctl fails, then the core file will be incomplete. This will not impact the system.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-CONFIG_POLICER_UNKNOWN_KEYWORD ### Response: (Severity: 3), (Category: OS), (Description: There is an unknown keyword in a policer definition. The policer may be assigned default characterstics.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TP_ALARM-4-TUNNEL_STATE ### Response: (Severity: 4), (Category: ROUTING), (Description: The MPLS-TP tunnel changed state.), (Recommended Action: If the state change is unexpected, confirm the local configurations as well those LSRs on the path of the LSPs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LSPV-7-MSG_TIMER ### Response: (Severity: 7), (Category: ROUTING), (Description: An error occurred during the initialization of global master or parent timer. The text of the message displays the failed operation with the error code. Process cannot continue execution in the absence of above timers.), (Recommended Action: Wait a few minutes and attempt to restart the LSPV_SERVER process. If the issue persists and a standby route processer (RP) node is available, switching over may help resolve the error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_MEAS-4-RSVP_TE_TUNNEL_BURST_INTERVAL_STRETCHING_ACTIVE ### Response: (Severity: 4), (Category: ROUTING), (Description: The requested PPS of RSVP-TE Tunnel delay measurement sessions is more than can be supported. The configured burst interval will be increased to ensure probe packets sent per second do not exceed the maximum allowed PPS. The RSVP_TE_TUNNEL_BURST_INTVL_STRECTHING_INACTIVE syslog will be issued once this condition is cleared.), (Recommended Action: Configure a larger RSVP-TE Tunnel delay measurement burst interval.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_CFGMGR_DELETE ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-2-BUS_CRITICAL ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PCIe bus error has occurred. The message has the device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSDIR-1-OPERATION_ABORT_NODE_DOWN ### Response: (Severity: 1), (Category: INSTALL), (Description: Quickstart operation aborted because the specified node was not ready.), (Recommended Action: The reason for this Quickstart operation failure has to be analyzed. Collect the show tech logs by running 'show tech-support qs' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-4-IOFPGA_GREEN_MODE_PWR_UPDT ### Response: (Severity: 4), (Category: DRIVER), (Description: Card manager has received an interrupt for Green mode power on the IOFPGA board. This is an update event which may have power up or down, Power down may be caused by power fault in one of the green mode power rails of the IOFPGA board specified in the log.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-NPU_0_TS_UPDATE_ERR_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Timestamp update error on NPU-0 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-0-SOFT_ERROR_RELOAD_RECOVERY_3 ### Response: (Severity: 0), (Category: PLATFORM), (Description: Soft error detected on bridge FGPA instance 3. Card will be reloaded to cover from this error.), (Recommended Action: Soft error are very rare due to Cosmic and other environmental factors. The probability of soft error on same device again is extremely low. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSV_APP-6-PIO_INFO ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message indicating that access size should be 4 or 8), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_IPV4_EA-5-DEBUG ### Response: (Severity: 5), (Category: PLATFORM), (Description: DNX IPV4-EA, Debug information), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_LOS_PORTQ ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_UTIL-3-MQ_OPEN ### Response: (Severity: 3), (Category: HA), (Description: Process hit a messege queue error.), (Recommended Action: Restart the process. If error persists, contact TAC with 'show cdm trace jid all' logs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-PREDICT_AVL_TREE ### Response: (Severity: 7), (Category: INSTALL), (Description: An unexpected error occured in the internal datastructures of the Package infrastructure. The current operation or request cannot be completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_EA-6-ERR_IMP_MULTIPLE_NTFCNS ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: A batch from IMProxy contained multiple notifications for a single interface. This should not occur but the situation has been recovered successfully by the PPPoE EA. No problems should be seen as a result.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-INIT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospf - show ospf trace all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-4-LFA_FRR_INVALID_CARD_TYPE ### Response: (Severity: 4), (Category: PLATFORM), (Description: LFA FRR is not supported for IPv6 when the protected or backup path is hosted on a non-Taiko line card. However, LFA FRR may still work if the protected and backup paths are hosted on different line cards, but FRR traffic loss times are not guaranteed.), (Recommended Action: Make sure that both the protected and backup paths are hosted on Taiko line cards. This can be done in a few ways in the IGP config for fast-reroute, such as excluding certain interfaces or specifying lfa-candidates for the LFA calculation for each protected link. Refer to the routing configuration guides for ISIS and OSPFv3 for more details.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-6-NODE_NORESET ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that the reset request caused by a critical alarm or heartbeat loss will not take effect because the node is being put in NMON state.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SYSDB_REG_NOTIFY_FAIL ### Response: (Severity: 7), (Category: OS), (Description: Sysdb notifier registration failure. This will impact the behavior of the dumper.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_ATM_V2-6-INFO ### Response: (Severity: 6), (Category: L2), (Description: ATM SPA OC3/OC12 informational message), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_CLI-3-AAA ### Response: (Severity: 3), (Category: MGBL), (Description: An AAA operation carried out by the HTTP CLI Agent returned unexpected results.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-TX_ALARM_SC_SYNC_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Condition raised by BITS transmitter when internal short-circuit resistance is approx 25 ohms or less.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-4-DISCOVERY_SLIP ### Response: (Severity: 4), (Category: ROUTING), (Description: Heavy CPU load or process blockage resulted in slip of discovery transmission. This may result in session/adjacency flap.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR provide a secure operating system? ### Response: Cisco IOS XR provides a secure operating system by implementing a microkernel architecture where most processes run in their own protected memory space. A failure in one process does not impact the kernel or other processes. Processes can also be restarted without impacting the entire system. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-3-MALLOC_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Allocating memory to a shim window failed due to one of the following reasons: 1. Invalid arguments passed to the function 2. Insufficient memory 3. Error occured while performing memory related operations), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-ERR_SYSDB_REG_VERIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: The process failed to register for verification of changes to its configuration data.), (Recommended Action: Restart of EIGRP might solve the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_400G_POD-3-UNSUPP_RX_NON_CH ### Response: (Severity: 3), (Category: FABRIC), (Description: The Rx POD detects an unknown error on a pod. The pod might not be functioning properly, and can cause cell drops, or corruption from received cells. There can also be a software bug such that the error is not handled), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SGT_HDR_EXT_FIFO_OFLOW_0_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress sgt hdr ext fifo overflow on xaui-0 bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-3-ERROR_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Verify process is up and running, give CLI: If it is still non-operational, use CLI: If it is still non-operational, perform RSP switchover or card reload.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-ERR_DELETESG ### Response: (Severity: 3), (Category: SECURITY), (Description: A configuration error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-ERR_SHADOW_WRITE_LIMIT ### Response: (Severity: 7), (Category: OS), (Description: shadow write limit exceeded.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IPV6_EA-3-ERR_MEM_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Typically, this is an error where the memory allocation / access fails. Here is a list of possible reasons for this message (not all-inclusive). 1) Memory exhaustion due to overall system load 2) Shared memory access failure 3) Memory leaks leading to resource exhaustion), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show cef ipv6 location <> show cef ipv6 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-SETPRIO_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: Changing locald priority failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-CRC_ERR_1_NPU_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: CRC error from NPU-1 on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-SRC_DST_CONFLICT ### Response: (Severity: 3), (Category: FORWARDING), (Description: It is not allowed to configure a tunnel with same pair of source and destination as an existing tunnel in the system. On display of this message user must change the source address or destination address to a unique pair of addresses that does not exist in the system. On successful resolution of this conflict, the tunnel interface state will be set back to UP state, provided the other criteria to bring up the interface are satisfied.), (Recommended Action: Modify source or destination address of the tunnel that caused the conflict to make a unique pair of source and destination that does not exist on any other tunnel on the box.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-ERR_PATH_ELEM ### Response: (Severity: 3), (Category: ROUTING), (Description: There was an error associated with path element operation, most likely due to low memory conditions. BGP may not operate correctly until the process is restarted.), (Recommended Action: Reduce other system activity to ease memory demands, then restart the process. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-ELO_LB_STATE ### Response: (Severity: 3), (Category: L2), (Description: CFM encountered an error while trying to retrieve the 802.3 Ethernet Link OAM loopback state of some physical interfaces, in order to report the state correctly in outgoing CCMs. This situation could indicate a problem in the Ethernet Link OAM daemon (elod) process, or that system resources are low, or a problem with another part of the system. It is likely that the interworking state reported in outgoing CCM messages will be incorrect.), (Recommended Action: Restarting the CFM Daemon or Ethernet Link OAM Daemon may help to resynchronize the loopback state. This error may occur as a result of memory exhaustion; attempt to resolve any memory issues before attempting to solve this problem. After system resource issues have been resolved, issue 'process restart cfmd' and 'process restart elod' on the node with the affect interfaces. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_9 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port 9.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port 9 interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-QDR_M_FREE_EMPTY_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Multicast free pages empty on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-3-PROT_SERVER_INIT_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: BFD could not initialize itself as PFI fast protect server, PROT_SERVER_BFD, since PFI fast protect infrastructure returned failure. BFD will continuously retry initialization in the background until successful. However, until successfully initialized, BFD session failure can not generate PFI fast protect event for PROT_BFD_SESSION_DOWN, which may prevent fast-reroute from being triggered.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPU_ASYNC_FIFO_FULL ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPU async FIFO full.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TEJAS_DRV-3-GENERIC_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The message is used to report TEJAS DRIVER generic errors.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_PFILTER_EA-7-INIT ### Response: (Severity: 7), (Category: L2), (Description: Initialization of packet filter process has failed due to one of the following reasons: 1) Failed to initialize ltrace. 2) Failed to register with debug. This would prevent process from logging debug messages. 3) Failure to connect with SYSDB. 4) Failed initialize internal permit/deny entries for IPv4/IPv6. These entries are needed for programming/removal of hardware entries for IPv4/IPv6 security ACLs. 5) Failed to initialize connection with interface manager proxy service. 6) Failed to initialize RLB (range logic block) checkpoint. This is needed for checkpointing range logic block information for restore on process restart. 7) Failed to initialize Feature EA DLL API needed for programming of hardware resources. 8) Failed to initialize callback function from Feature EA DLL for compiling IPv4/IPv6 TCAM entries needed for security ACL programming in hardeare. 9) Failed to initialize callback function from Feature EA DLL to handle reprogramming of RLB and IPv6 source prefix compression table request from TCAM manager. 10) Failed to initialize feature checkpoint info. This is needed for checkpointing IPv4 and IPv6 security ACLs programmed in hardware. 11) Failed to initialize callback functions from ACL configuration manager to perform hardware resource checks and ACE resequencing. 12) event_block failed. This indicates process has encountered unexpected error while waiting for events. 13) Failed to initialize callback functions for receiving incremental updates for IPv4/IPv6 security ACL configuration.), (Recommended Action: No action is required. Process will be restarted. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-AUTO_ABORT_TIMER_STOPPED ### Response: (Severity: 4), (Category: INSTALL), (Description: The auto-abort timer has been stopped.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_BAG_DECODE ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-bandwidth adjustment threshold feature? ### Response: The MPLS TE auto-bandwidth adjustment threshold feature specifies the percentage difference between the current tunnel bandwidth and the measured output rate that triggers an auto-bandwidth adjustment. A lower threshold means auto-bandwidth adjusts the tunnel bandwidth more frequently, while a higher threshold means adjustments occur only for more significant rate changes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR bandwidth protection feature? ### Response: The MPLS TE FRR bandwidth protection feature allows bandwidth to be reserved for backup tunnels to ensure that sufficient bandwidth is available for fast reroute traffic after a failure. It prevents backup tunnels from being used for other traffic and ensures that FRR can always redirect traffic successfully. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERG_CLIENT-4-ASSERT ### Response: (Severity: 4), (Category: INFRA), (Description: The SERG client process hits some abnormal condition. These warnings will not affect functionality of SERG.), (Recommended Action: Collect the traceback associated with this Log and contact the engineer.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-3-PUBLISH_DELETE ### Response: (Severity: 3), (Category: SERVICES), (Description: An error has occurred while indicating the deletion of the given service attachment removal to nodes other than that local to the interface indicated. Packet diversion may now be inconsistent. The error string will give more detail on the type of error that has occurred.), (Recommended Action: For non-resource errors, adding and removing a service attachment for the interface indicated in the message may remove the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the error is a resource error this will be indicated in the error description given. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_ISOLATION-7-SUCCESS ### Response: (Severity: 7), (Category: PLATFORM), (Description: This message indicates that the requested node isolation action completed successfully.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-3-RX_MISS ### Response: (Severity: 3), (Category: PLATFORM), (Description: Some packets are dropped due to receive buffer overflow in DMAC device. The CLI above will show which queue dropped the packet. This would in general indicate an unexpected CPU busy condition wherein the software is slow in processing packets.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-3-CTP2_PWR_SUPPLY ### Response: (Severity: 3), (Category: PLATFORM), (Description: --), (Recommended Action: Contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPP-3-MSG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: A unexpected failure has been detected while MPP configuration was being applied.), (Recommended Action: Restarting the concerned process might solve the issue. If the message recurs, issue the following command 'show mgmt-plane trace client both' to gather data and provide the gathered information and the exact error message as it appears to the Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-EBS_CPU_HP_TAIL_DROP ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress Buffer and Scheduling to CPU high priority tail drop.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TURBOBOOT-3-INVALID_DEVICE ### Response: (Severity: 3), (Category: INSTALL), (Description: The TURBOBOOT setting in ROMMON was enabled, but the requested device is unavailable. The EASYBAKE/TURBOBOOT variables are cleared. The node will be reset. Please repair the device and retry the boot sequence.), (Recommended Action: Check for boot device corruption by running disk checks using 'fsck' disk check CLI. Based on the outcome of disk check take corrective action and retry turboboot.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-2-KERNEL_CORE_TRIGGERED ### Response: (Severity: 2), (Category: INFRA), (Description: To allow for triage of an issue involving the kernel, a kernel core had to be automatically created.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-7-SETS_REBUILD_INCONSISTENCY ### Response: (Severity: 7), (Category: ROUTING), (Description: The policy_repository process failed to rebuild the set references for the policy in question. This will result in an inconsistent state in the policy_repository and the process should be restarted. This could result in policies not functioning properly.), (Recommended Action: The policy_repository process should be restarted to clean up the internal inconsistency. Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How do you initiate a system reboot after software installation in Cisco IOS XR? ### Response: A system reboot after software installation in Cisco IOS XR can be initiated using the 'install reboot' command, which restarts the router to apply the new software configuration. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE1_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE1_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTT1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-2-TX_CH_FAULT ### Response: (Severity: 2), (Category: FABRIC), (Description: The Tx POD detects a fault on a channel. The channel might not be functioning properly, and can cause cell drops, or corruption in the downstream.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC16 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-4-WARNING ### Response: (Severity: 4), (Category: SECURITY), (Description: Internal Warning.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPU_PKT_F2_FULL ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPU packet FIFO 2 full.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HPI-3-LOCK_NOT_RECOVERABLE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to make the mutex in consistent state results in not recoverable state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DAISYDUKE_DRIVER-4-DD_USBPASSIVE_INFO ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates insertion or removal of usb passive modules), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APP_OBJ-3-NULL_PARAM ### Response: (Severity: 3), (Category: MGBL), (Description: This is an internal error that invalid parameter is encountered.), (Recommended Action: Contact TAC and provide required_info, which will be used only for internal diagnosis purpose.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEV2-3-INVALID_RSP ### Response: (Severity: 3), (Category: OS), (Description: MB response packet error.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-CONFIG_BATCH_ERROR ### Response: (Severity: 4), (Category: INFRA), (Description: XLNCd has received updates from the Linux kernel about interface attributes. XLNCd has then tried to apply these updates as IOS-XR configuration, but hit an operational error.), (Recommended Action: If the problem persists, restart the process. If the problem persists through process restarts, If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPGALIBASGARD-3-FPGA_PLL_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates an error occurred due to fpga PLL lock failure.The PLL lock has reached the maximum retry.), (Recommended Action: Configure and remove loopback in the interface level using CLI -loopback line -no loopback This will reset the PLL. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_THOR_L2FIB-3-HW_INIT_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the Platform LC Hardware in L2FIB component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-2-CONN_OPEN_FAILED ### Response: (Severity: 2), (Category: OS), (Description: lpts_pa process from v2 failed to connect to lpts_pa in v1), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SDS-4-FAILED_PARTNER_NODE_STATE ### Response: (Severity: 4), (Category: INSTALL), (Description: While synchronizing a reload between a node and its partner, the state of the partner node could not be ascertained.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_ATOM-6-DEBUG_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB ATOM component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-6-BADSFP ### Response: (Severity: 6), (Category: PLATFORM), (Description: nV Edge Control ports needs Cisco supported SFPs.), (Recommended Action: 'Plug in a Cisco supported 1Gig SFP') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-4-CALL_ALLOC ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The VPDN CALL infra has failed to allocate memory. This may be due to low memory conditions on this particular RP/LC, or this client may be using more memory than it is allowed.), (Recommended Action: Reduce system scale.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-3-WRONG_FLOW ### Response: (Severity: 3), (Category: OS), (Description: 'GSP flow zone information is incorrect.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_MQ_FULL_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue full error on XAUI 0 MQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-DEV_CFP_COMPLIANCE_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A compliance error was detected during CFP initialization. A compliance error is due to checksum error, EEPROM CRC error, vendor data error, or decryption error. The CFP is the pluggable optics on the line cards. CFP initialization may happen when linecard boots up, CFP OIR and line card process restart. The optics will not be enabled if an CFP compliance error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install activate auto-abort-timer command in IOS XR? ### Response: The 'install activate auto-abort-timer' command is used to set a timer for the automatic rollback of an installation if the user doesn't commit the changes within the specified time. This provides a safety mechanism to revert to the previous software set if something goes wrong during the installation. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-SOCKLITE_INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The CE-TFTP server process will exit, since it failed to initialize the sock-lite data base. The process will respawn itself.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-7-CARD_FAILURE ### Response: (Severity: 7), (Category: PLATFORM), (Description: This message indicates a generic failure in the invmgr w.r.t the cards in the inventory. This can be a any failure that occurs commonly either during bootup or in RUN state), (Recommended Action: These failures need to be reviewed by the DE to ensure the issue severity. Please contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-6-BYPASS ### Response: (Severity: 6), (Category: DIAG), (Description: This is an informational message stating that diagnostics testing was not performed on the card because diagnostic testing was disabled in the user configuration.), (Recommended Action: This behavior is consistent with the user configuration and no action needs to be taken. If you want to run bootup diagnostics, enable bootup diagnostics by using the diagnostic bootup command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-SHIP_INFRA ### Response: (Severity: 3), (Category: L2), (Description: ship_infra registration failed.), (Recommended Action: No action is required. Process will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If restart din't fix the problem) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-3-script_failed ### Response: (Severity: 3), (Category: OS), (Description: Failed to run a script to collect debug information.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-4-HIST_UPDATE_FAILED ### Response: (Severity: 4), (Category: INFRA), (Description: When updating the history, a write to operation history failed. This should not affect the install operation, but means that operation history may be incomplete or inconsistent.), (Recommended Action: If the issue persists, please obtain the output from the console or system log, and the entire output of the following commands: show tech-support install) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-2-INTR ### Response: (Severity: 2), (Category: L2), (Description: A CPP hardware interrupt has occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-7-DEBUG_MSG ### Response: (Severity: 7), (Category: L2), (Description: This is a debug message in the jacket driver to indicate anomolies which are not critical. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-FALLBACK_SESSION_STOP ### Response: (Severity: 5), (Category: L2), (Description: The MKA Session identified by the interface, and CKN is getting terminated. Possible reasons could be macsec config delete on the interface (or) no active pre-shared key present for the given CKN), (Recommended Action: If this is not expected, contact cisco-support by sharing the tech-support macsec.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-HIGH_VOLTAGE_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ voltage greater than or equal to the high voltage warning threshold. The QSFP+ is the pluggable optics on the line cards. The voltage threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check the 'show environment voltages'. If the system voltage is normal then replace the optics with working one (if any). If the system voltage is not normal, then make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-IO_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred while initializing the IO thread in the speaker process. The process will be restarted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_OC3_OC12-3-ERR_IF ### Response: (Severity: 3), (Category: L2), (Description: The SPA driver on the linecard failed to call SONET controll or POS interface related system function. The issue may affect the creation of SONET controller or POS interface while the SPA is booting, reloading or SFP OIR with different optics rate. %s - error message indicating location and the reason of the error), (Recommended Action: - Try to do the SFP OIR for a few more times; - If the issue persists, reload the SPA with the command: hw-module subslot 0/x/x reload then check if all the POS interface are created, if not, reload LC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_THREAD_MUTEX ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an unexpected error performing a mutex operation. The process may restart to attempt to recover. This is possibly due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-6-ERR_ASIC_OOR ### Response: (Severity: 6), (Category: FABRIC), (Description: Ingressq block is unable to get packet memory for the incoming packets. This condition is caused by over subscription or hitting the Packet Per Second rate. This will affect the QOS. Thus it is recommended to reduce the packet rate to this MSC.), (Recommended Action: Reduce the incoming packet rate to this MSC as under the OOR condition the QOS If the OOR is seen in non-oversubscribed case, contact TAC Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-3-ADM1066_WRITE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This error message indicates write failure on ADM1066 device.), (Recommended Action: Please try to collect error code and verfy the address.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CBC-2-CANBUS_PWR_SEQ_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: The CBC alarm indicating that the power up sequence has failed. The proper functioning of the board requires that a successful application of power be applied to the board in the proper sequence.), (Recommended Action: Reboot the LC. If the problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-PERF_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while trying to Start/Stop the timer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GT_ETH_MGMT-3-DEBUG_INIT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error detected when initializing the eth mgmt debug messages. process will restart automatically to recover from this error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-CRRS4_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a parity error), (Recommended Action: Please correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTAGENT-2-SDR_PART_PREP_FAILED ### Response: (Severity: 2), (Category: INFRA), (Description: An internal error occured in the middle of XR partition preparation. This will result in the SDR going to shut-off state.), (Recommended Action: Reload the card to recover. A new XR partition will be prepared upon card reload.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_DYNREG-3-AP_REGISTER_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered as attach point data was being registered for verification. At this point is would be best to restart the policy_repository to try to clear this inconsistency.), (Recommended Action: Restart the policy_repository process and check for re-occurence of issue If problem persists, the please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR-4-queue_err ### Response: (Severity: 4), (Category: PLATFORM), (Description: Application tried to handle a buffer not part of queue. Use the CLI 'show controllers backplane ethernet trace buffstat location *' to determine if there is a queue leak.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers backplane ethernet trace location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers backplane ethernet trace location output, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARB_CLIENT-3-GEN_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates an error condition in client library api while communicating with the server process. It may be caused due to invalid api arguments by client process or a transient condition while the server process is initializing the ASIC), (Recommended Action: This message may indicate a transient condition while the card is booting up. Please check if the error message is seen continuously even after the card has reached IOS-XR RUN state. And if so, then try to power cycle the card. If the message is seen in every power cycle after the card is in IOS XR RUN state then please contact tech-support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_FIND_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: An unexpected error occurred looking up an interface handle from an interface name. This may be due to a low memory condition but is most likely to be an internal programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How do you configure OSPF interfaces in Cisco IOS XR? ### Response: To configure OSPF interfaces in Cisco IOS XR, go under the interface configuration mode and use the 'router-id' command to specify the OSPF process. Then use 'area ' to assign the interface to a specific area. You can also set interface-specific timers, authentication, and other parameters here. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_0_ERR3_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 0 ran into error-3 on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of CSNPs and PSNPs in IS-IS? ### Response: CSNPs contain a complete list of all LSPs in the IS-IS database. They are sent periodically by the DIS on broadcast networks to synchronize databases. PSNPs are used to request missing LSPs from a neighbor and contain a subset of LSPs. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_CFEC_AIS_DEM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-2-STANDBY_SHUTDOWN_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: The shutdown of the standby SC/RP node failed during the chassis shutdown process.), (Recommended Action: Please power off the chassis manually.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE7_CODE_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE7_CODE_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_NSF_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-SHUTDOWN_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: TACACS+ process failed to shutdown properly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RLOGIND-3-ERR_MALLOC ### Response: (Severity: 3), (Category: IP), (Description: Internal error. System is out of memory - malloc failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARB-7-ERR_EXIT ### Response: (Severity: 7), (Category: PLATFORM), (Description: An error occurred in arbiter driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-3-DEBUG_THREAD_CREATE ### Response: (Severity: 3), (Category: OS), (Description: QNET process tried to create event debug pthread for the process but encountered an error The process will exit and respawn again), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MACSEC_CFG-3-INVALID_CONFIGURATION ### Response: (Severity: 3), (Category: L2), (Description: Cannot configure hw-module macsec-mode location all if LC nodes are already configured. Remove that configuration before attempting to configure for all.), (Recommended Action: Informational, configuration error to be fixed before commit.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-4-LISP_TOP_RLOC_AUDIT ### Response: (Severity: 4), (Category: IP), (Description: 'This message is a warning that one or more ' 'configured router lisp instances are missing the ' 'locator-table configuration. Without this configuration, the ' 'lisp instance is not operational.'), (Recommended Action: 'The operator must configure the ' 'locator-table below the router lisp instance(s), or ' 'router lisp instances which are no longer required should ' 'be unconfigured.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-6-ILLEGAL_CBC_VERSION ### Response: (Severity: 6), (Category: PLATFORM), (Description: Informational condition and/or failure. The process can continue functioning as expected despite the failure.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-NO_I2C_TOPO_FILE ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC driver was not able to retrieve I2C topology file to perform basic driver initialization. Process will be restarted to attempt to recover from this.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_CHOPPER-3-IO_ERR ### Response: (Severity: 3), (Category: L2), (Description: SPA process failed to read/write. The process will automatically respawn up to a fixed number of times to try and recover.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_DOM_SENSOR_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is raised when DOM sensor on a satllite port crosses either high or low threshold limits for that sensor type.), (Recommended Action: If the problem persists provide output of: Copy the error message exactly as it appears on the console or in the system log. Issue the (RP)# show controllers phy command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (RP)# show controllers phy output, call your Cisco technical support representative and provide the representative with the gathered information. to technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different ways to monitor processes in Cisco IOS XR? ### Response: Cisco IOS XR provides several commands to monitor processes, such as 'show processes', 'show processes cpu', and 'show processes memory'. These commands display information about running processes, CPU utilization, memory usage, and other process-related statistics. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-1-CONSOLE_SESSION_ANYWAY ### Response: (Severity: 1), (Category: MGBL), (Description: The RS232 DLL tried to apply a template to the console and failed, but we are attempting to start a session anyway to try and ensure that it's possible to log onto the router from the console. This may mean it's impossible to gain terminal access any other way (ie via telnet, ssh, etc).), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the *param* command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the *param* output, call your Cisco technical support representative and provide the representative with the gathered information. show running-config) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-2-ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Error in CPU Control FPGA operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-INIT_ERR ### Response: (Severity: 0), (Category: PLATFORM), (Description: Network Processor Initialization encountered a critical error that renders the system unusable.), (Recommended Action: Check if the board comes up fine after the LC reboot. If the board does not recover - it will need to be replaced.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTY-6-COMMAND_LINE_ARGS ### Response: (Severity: 6), (Category: MGBL), (Description: Command line arguments were passed to the VTY Device DLL when it was initialized. It does not expect to be passed any arguments.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR_API-6-CEMGBL_GOT_NOTIF_FROM_INT ### Response: (Severity: 6), (Category: PLATFORM), (Description: Cemgbl got notification from INT switch and displays the count and 1st index of it.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZEN-3-HARDWARE_INIT_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: The message indicates that the pci initialization for the Zen FPGA had failed. As a result, the Zen driver cannot initialize the Zen FPGA, and exits.), (Recommended Action: Zen driver, as a mandatory process, is restarted automatically upon exit. After multiple restart, procmgr will bring to failed state. In such scenarios, first, collect the Zen driver traces, and router logs for debugging. Then, reload the card) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-OPERATION_SUCCESS ### Response: (Severity: 2), (Category: INFRA), (Description: Specified install operation in the message finished successfully.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_TOPAZ-3-ERR_QAD_SET_WM ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to set the watermark of the indicated qad queue. This should be because of some issues with the qad queue %s - high or low watermark %p - QAD queue id), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-INTERNALERR ### Response: (Severity: 7), (Category: INSTALL), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-6-BAY_OPTICS_OIROUT ### Response: (Severity: 6), (Category: PLATFORM), (Description: OPTICS enity is removed from the line card), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_7_LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature less than or equal to the low temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CPAK with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-IFINIT ### Response: (Severity: 3), (Category: ROUTING), (Description: OSPFv3 failed to initialize data structures for an interface.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show ospfv3 interface - show running-config) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE0_CODE_ERR_HIGH_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE0_CODE_ERR_HIGH interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD_inv-3-MEM_ALLOC_FAIL ### Response: (Severity: 3), (Category: HA), (Description: This is a generic error msg for memory allocation failure. The Process tried to allocate a memory and it wasn't succesful. Can happen when system is running low in memory), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-3-TAM_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: TAM Error error observed while interacting with TAM.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-LOS_INFO ### Response: (Severity: 3), (Category: OS), (Description: An unexpected error occurred.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-FATAL_AER_RECEIVED ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. Fatal AER is received. This issue may be SFE ASIC is not responding to PCIe transactions. 2. There is a uncorrectable PCIe error.), (Recommended Action: PON Reset the ASIC. Collect all the event logs and the output of the following commands executed from the CLI of the active RP: 1. 'show processes sfe_driver location ' 2. Collect all traces: 'show controller sfe trace all location ' 3. dmesg and /var/log/messages from host and sysadmin VM If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_LA_QOS-2-HW_LOCK_ACQUIRE_FAILED ### Response: (Severity: 2), (Category: QOS), (Description: Prior to taking action to update device, global HW lock must be taken. This message shows up if the lock is not acquired.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-SIGEMT ### Response: (Severity: 4), (Category: OS), (Description: Signal info), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-PDMA_RAM_PARITY_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Indicates an uncorrectable parity error occurred on this internal SRAM. %s - name of ram that error occurred %x - key of error node recorded %s - error data), (Recommended Action: if this happen continous, reload the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-7-ERR_REGISTER_GET ### Response: (Severity: 7), (Category: FABRIC), (Description: An attempt to read a Hardware register failed. This could result in inconsistent behavior of the device.), (Recommended Action: Run diags on the board and contact TAC support. If it is possible to isolate the trigger point for the read failure, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_TOPAZ-7-ERR_EVENT_CONN_NOTIFY ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to register event handler for disconnection or connection error event. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_MLIB_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Failed while initializing multicast library.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_TUNNEL_EA-3-UPDATE_ERR1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the CRS platform specific code software to indicate errors that happened during an update event. This error is most likely caused by a temporary situation, so is unlikely to occur. %s - indicates the reason for the failure. %s - is the decoded error reason.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_TUPLE ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The process failed to unpack a tuple.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SI-3-INITFAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of the SI process on a particular node. The process will be restarted. Until the process starts successfully, any SI configuration is not accepted.), (Recommended Action: Retry the config/show operation after SI process restart.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISK_DRIVER-3-FAILED_TO_CREATE_THREAD ### Response: (Severity: 3), (Category: PLATFORM), (Description: pthread_create() returns error. If this occurs , event related operations will not occur.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XBAR_CLIENT-3-GEN_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates an error condition in client library api while communicating with the server process. It may be caused due to invalid api arguments by client process or a transient condition while the server process is initializing the ASIC), (Recommended Action: This message may indicate a transient condition while the card is booting up. Please check if the error message is seen continuously even after the card has reached IOS-XR RUN state. And if so, then try to power cycle the card. If the message is seen in every power cycle after the card is in IOS XR RUN state then please contact tech-support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-TX_OVF_ERR_FIA00 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA00 Tx overflow error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_5_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-SHM_INIT_ERR ### Response: (Severity: 3), (Category: OS), (Description: There was a problem to initialize shared memory file allocation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture - show shmwin trace server location 0/x/CPUx - process core of shmwin_svr) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_0_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure BGP ORF (Outbound Route Filtering) in IOS XR? ### Response: BGP ORF in IOS XR is configured to allow a BGP speaker to send a set of route filter conditions to its BGP peer. router bgp 65000 neighbor 203.0.113.7 capability orf prefix-list send commit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-5-CLIENT_LIMIT_REACHED ### Response: (Severity: 5), (Category: TOPOLOGY), (Description: clustermgr received too may connection requests.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Restart erroring process. collect show tech spi *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_MEAS-4-ENDPOINT_BURST_INTERVAL_STRETCHING_ACTIVE ### Response: (Severity: 4), (Category: ROUTING), (Description: The requested PPS of Endpoint delay measurement sessions is more than can be supported. The configured burst interval will be increased to ensure probe packets sent per second do not exceed the maximum allowed PPS. The ENDPOINT_BURST_INTVL_STRECTHING_INACTIVE syslog will be issued once this condition is cleared.), (Recommended Action: Configure a larger Endpoint delay measurement burst interval.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: The Fabric driver was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_A_DATABUS_STUCK_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI-A databus stuck on bridge instance-2.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDLD-3-OUT_OF_MEMORY ### Response: (Severity: 3), (Category: L2), (Description: A UDLD process failed to allocate sufficient memory for its processing. This could be due to a shortage of system resources. The process will restart and attempt to recover.), (Recommended Action: The UDLD process will restart in an effort to recover from the low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-7-ASYNC_ATTACH_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to attach handler for async events.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_3_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Tx power greater than or equal to the high Tx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Tx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Replace the QSFP+ with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_EDM-3-DECODE_FAILED ### Response: (Severity: 3), (Category: IP), (Description: IPV4 could not decode data supplied by the indicated external data manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-ROOT_USERDB_LOCK_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: A lock operation on shared resource, called by locald lwDB failed due to the mentioned error.), (Recommended Action: Collect the output of show logging and inform Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_INARP-3-IF_VC_CLASS ### Response: (Severity: 3), (Category: L2), (Description: A vc-class was configured on an interface but couldn't be applied for the given reason. This may happen in case, the vc-class detach or attach events with sysdb return a failure. first %s - vc-class name second %s - interface name third %s - Error string), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_13_LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-FAN_SPEED_MAX ### Response: (Severity: 4), (Category: PLATFORM), (Description: High temperature condition of one or more components has caused the fan speed to rise to the maximum allowed for the 40C temperature profile.), (Recommended Action: Ensure chassis has sufficient power modules. Configure 'power budget profile extended-temp' from admin config. Reduce the ambient temperature if possible. Replace the cards that are heating up.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB-7-ERR_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered the specified error during the initialization sequence. This facility is deemed crucial and hence the process is automatically restarted on this failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON_FAN_ALGO-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an information log.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HD-2-DEV_HARDDISK_DEVICE_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Hard disk encountered media errors), (Recommended Action: This error is a momentary error and software should be able to correct it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_AB_INTR_FIFO_ORUN_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_AB_INTR_FIFO_ORUN interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-INTERNALERR_RC ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show tech-support routing ospf) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-POLICY_MISMATCH ### Response: (Severity: 3), (Category: SECURITY), (Description: Phase I policy parameters negotiation failed with peer.), (Recommended Action: 'Contact the remote peer's administrator') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-DEVICE_NOT_READY ### Response: (Severity: 7), (Category: OS), (Description: no device ready yet for notified feature), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACE_TSB_LC-6-INFO ### Response: (Severity: 6), (Category: SECURITY), (Description: ACE TSB Informational message), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESDMA-6-MLAP_CONN_LOST ### Response: (Severity: 6), (Category: INFRA), (Description: MLAP on the given location has restarted or stoped. Hence connection between MLAP and ESDMA has been lost.), (Recommended Action: Check on the MLAP process in the given location) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-7-ERR_RECV_TE_MSG ### Response: (Severity: 7), (Category: ROUTING), (Description: The process has received an invalid length TE message. As a result, the TE message is ignored and TE tunnel may not come up.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBDLLMGR-4-POSSIBLE_MISSING_INFO ### Response: (Severity: 4), (Category: OS), (Description: Buffer given to the devctl routine is smaller than required. This will cause missing dll-text segment in the core file.), (Recommended Action: Collect system log information. Collect 'show dll' information from the node which printed this message. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-MD5_VERIFY_FILES ### Response: (Severity: 7), (Category: INSTALL), (Description: Failed to perform file validity check on each file to see if they are valid or not, so processing of the current operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-SRV6_LOC_UPDATE_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured while processing an SRv6 locator update received from the RIB.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the IS-IS process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-4-OS_BOOT_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: OS running on the indicated card is reporting a warning condition during bootup.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-SESVI_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: CGN_MA failed to register with SESVI for interface programming notifications. The process will restart under this scenario.), (Recommended Action: Try restarting the CGN process showing this error. Please contact support if the issue does not get resolved after process restart.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-6-PCI_BUS_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: A PCI bus error has occurred. The message has the device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-2-DUI_VTP_FAILURE ### Response: (Severity: 2), (Category: L2), (Description: The NPU ASIC has VTP issue. HW init will fail), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rlogin-3-ERR_BEST_ROUTE ### Response: (Severity: 3), (Category: IP), (Description: Socket operation failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VERSMGR_LIB-7-FILESYSTEM ### Response: (Severity: 7), (Category: INSTALL), (Description: A Version Manager library was unable to carry out a filesystem operation. Installations may not produce the expected results.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-CONNECTION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The error occurs,if sending message to the server gets failed.), (Recommended Action: Please collect the console log,and the following: Copy the error message exactly as it appears on the console or in the system log. Issue the cmd command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the cmd output, call your Cisco technical support representative and provide the representative with the gathered information. show cef trace loc <>, show cef platform trace all loc <>, show cef platform services resource oor common loc show cef platform services resource shm-objects common loc show cef platform services trace common all reverse loc show cef platform services trace common errors reverse Also notice if the error message is transient or persistent. Report to your technical support representative. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-INTF_TOO_LONG ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Each item in the XR_INTERFACES list must not be longer than the maximum interface length.), (Recommended Action: Check the format of the XR_INTERFACES environment variable.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_14_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_EVM_CBACK_ATT_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to register a callback handler due to the error. This is an initialization error and implies that the function in IS-IS will not be able to operate correctly. The IS-IS process must be restarted in order to recover.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart the IS-IS process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_SDFEC_LOF ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_ERRORS-3-ERR_SYSDB_BAG_ENCODE ### Response: (Severity: 3), (Category: L2), (Description: ASIC error library encountered a SYSDB encode error while performing the indicated operation.), (Recommended Action: An error would be reported to the client application which should handle this condition appropriately. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_6_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE_ERR_5_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE_ERR_5 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-6-PORT_STATE_CHANGE_ADMIN_TEST ### Response: (Severity: 6), (Category: INFRA), (Description: Informational message indicating that the the admin state of the specified port has changed to test.), (Recommended Action: This is an informational message and does not necessarily indicate a problem. This message is expected when the port's admin state is changed via CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_PA_INTR_MAX_SZ_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_PA_INTR_MAX_SZ_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-I2C_WR_TIME_OUT ### Response: (Severity: 3), (Category: DRIVER), (Description: IOFPGA I2C write is timed out and did not receive DONE signal.), (Recommended Action: Check the device for which the write has timedout.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMC-7-UNEXPECTED_MULTIPLE_RESPONSES ### Response: (Severity: 7), (Category: SYSDB), (Description: The SysDB Medusa process received multiple responses for a message type for which only a single response was expected.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show mpls traffic-eng fast-reroute database' command in IOS XR? ### Response: The 'show mpls traffic-eng fast-reroute database' command is used to display the Fast Reroute (FRR) protection information for MPLS TE tunnels. It shows the tunnel name, the protected interface, the backup tunnel used for protection, and the state of the protection (ready or active). This command is useful for verifying FRR protection for TE tunnels. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROL_DRIVER_RSP4-3-IDPROM_RETRIEVAL_FAILED ### Response: (Severity: 3), (Category: DRIVER), (Description: Failed to retrieve idprom for the card in a particular slot), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_DAP_POOL_EXHAUSTED ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_STAT_VEC_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-0 state error on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_DEBUG_INIT_EVENT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error related to the debugging subsystem occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-5-ASIC_ERROR_THRESHOLD ### Response: (Severity: 5), (Category: PLATFORM), (Description: ASIC errors have exceed the threshold.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_SERDES_0_FAIL_1 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data serdes link 0 failure on FIA 1.), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-INTF_REG_DROPPED ### Response: (Severity: 3), (Category: ROUTING), (Description: An Interface registration operation request received when server initialized in asynchronous mode or vice versa; or when server is not ready..), (Recommended Action: Controller and/or agent must ensure that Interface registration operation requests are sent only when server is ready. If message is still seen after meeting these conditions, contact Cisco for support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-3-HLPR_SYSDB_INIT_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The Spa hlpr sysdb init failed due to - A SysDB client attempted to register for verification or as an EDM on a path which was already registered, registering more than once for verificatin is due to multiple RP's present in the node. - spa_cfg_hlpr abort - On restart spa_cfg_hlpr registration for verification may fail - During RPFO %s - Process name %s - error/warning condition), (Recommended Action: Try for process restart If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-3-COULD_NOT_GET_NODEID ### Response: (Severity: 3), (Category: L2), (Description: The Ethernet Link OAM Daemon failed to determine the ID of the node on which it is running. It will exit, and should be restarted by System Manager.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-3-BAD_READ ### Response: (Severity: 3), (Category: OS), (Description: RDS library uses ENS/GSP services to read/write data. While using ens_read API to read, it returned failure. ens_read returned bad len. Underlying GSP/ENS might have some problem), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-ABORT_FGID_WRITE ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-6-QUEUE_GREEN ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an indication queue length is back to normal for dpa client), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_8_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPGAMGR-3-INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The FPGA Manager, interrupt handling thread, failed to spawn. %s-Error Description.), (Recommended Action: Please re-load the FPGA manager. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-MALLOC_FAIL ### Response: (Severity: 3), (Category: SYSDB), (Description: Unable to allocate memory for message buffer.), (Recommended Action: Check the overall system and process memory usage.If it pertains to the process showing the error, then restarting the process may fix the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-INIT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Init error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_AGG-6-PPU_END ### Response: (Severity: 6), (Category: FABRIC), (Description: FSDB aggregator has completed Calvados plane by plane upgrade successfully.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QAD_LIB-3-SHMWIN_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Shared memory access operations like init,open or bind might have failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2RIB-2-INIT ### Response: (Severity: 2), (Category: L2), (Description: L2RIB initialization has failed due to the reason indicated in the message. The process shall attempt self recovery by restarting.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFL_PD-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error happened during OBFL initilization), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. .) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPFPGA-3-IOFPGA_ACCESS ### Response: (Severity: 3), (Category: PLATFORM), (Description: IOFPGA access Failure/Success while accessing device), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-INT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ET0_INTR_CRC16_CHK_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ET0_INTR_CRC16_CHK_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETFLOW-4-WARNING_CFG_APPLY ### Response: (Severity: 4), (Category: MGBL), (Description: This message indicates that a configuration that was previously verified cannot be applied due to the reason specified. This may happen if a configuration that was applied to a Bundle interface cannot be applied due to either resources not being available in the Line Card where the member resides, or some configuration mismatch was detected.), (Recommended Action: Check the reason for the application failure and correct it as appropriate.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-7-ERR_INTERNAL_SW ### Response: (Severity: 7), (Category: FABRIC), (Description: The Fabric driver encountered the annunciated internal SW error. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-CARD_YELLOW_OVERTEMP ### Response: (Severity: 4), (Category: PLATFORM), (Description: Card hotspot temperature has risen at or over configured yellow threshold.), (Recommended Action: The customer has configured this threshold. Thus on this alarm , the customer can react accordingly. Card can operate in this range but is above yellow threshold.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BMP-4-ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the process. This resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_HFR-7-ERR_HEARTBEAT_FAILURE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server heartbeat monitoring mechanism detected interruption in the periodic 'Hello' messages.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-DEBUGINITFAIL ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: The debug support initalization failed in the packet server. It will be restarted by sysmgr and should recover.), (Recommended Action: If packet manager is unable to start up after several restarts by sysmgr, please collect the 'sh log' output and contact your customer support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARB_CLIENT-3-GEN_ERR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates an error condition in client library api while communicating with the server process. It may be caused due to invalid api arguments by client process or a transient condition while the server process is initializing the ASIC), (Recommended Action: This message may indicate a transient condition while the card is booting up. Please check if the error message is seen continuously even after the card has reached IOS-XR RUN state. And if so, then try to power cycle the card. If the message is seen in every power cycle after the card is in IOS XR RUN state then please contact tech-support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnetdscp-4-DSCP_EXTRACT ### Response: (Severity: 4), (Category: IP), (Description: An error occurred whilst trying to extract dscp configured value. Server will use default dscp value instead.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: adminexec-3-ACCT_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: failed to send accounting record), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-SHOW_EDM_CLOSE ### Response: (Severity: 3), (Category: OS), (Description: Cleanup for EDM failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-INVALID_ACT_MSG ### Response: (Severity: 3), (Category: OS), (Description: The virtual service activate message was received, however, the data it contained could not be interpreted.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-3-ERR_UNSUPPORTED_GROUP ### Response: (Severity: 3), (Category: SECURITY), (Description: RADIUS does not support command authorization and command accounting.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPHC_PROFILE-3-MEM_ALLOC ### Response: (Severity: 3), (Category: L3), (Description: The process failed to allocate memory for the specified resource.), (Recommended Action: Check how much memory is available at the location where the error was reported. If the system has enough memory and if the error message persists, contact TAC with required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_FPGA-3-ERR ### Response: (Severity: 3), (Category: L2), (Description: Plim datapath fpga driver errors. Typically these errors indicate failure in system services or bad programming of the hardware.), (Recommended Action: Check whether process 'plaspa_server' is up and running. Check if the linecard reported any other errors and/or traffic loss was observed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-bandwidth collect frequency feature? ### Response: The MPLS TE auto-bandwidth collect frequency feature specifies how often auto-bandwidth measures the output rate of a tunnel before making a bandwidth adjustment. A higher frequency means auto-bandwidth reacts more quickly to traffic changes, while a lower frequency means bandwidth adjustments occur less often. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_EVM_ATTACH ### Response: (Severity: 4), (Category: L2), (Description: SSRP failed to register a handler for the specified class of event. This is an initialization error and implies that SSRP will not be able to operate correctly. The PPP MA process will abort and be restarted in an attempt to recover. The cause may be a resource starvation problem but is most likely to be an internal programming error. The error message should give more details.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart the PPP MA process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-1-OOR_RED ### Response: (Severity: 1), (Category: PLATFORM), (Description: This is a severe error message in the OFA module to indicate high usage of OFA resources.), (Recommended Action: Please collect the OFA resource information (show controller npu resources all location all). Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEA_DLL-3-PRM_SSH_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Feature EA DLL encountered error in completing PRM SSH operation. This can lead to failure of configuration.), (Recommended Action: If this message is seen during adding acl to the interface, then configuration apply will fail. May be retrying to apply the acl conifg will succeed. If seen during removal of the acl config, this may lead to acl configuration hardware inconsistent. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-3-SYSDB_GET ### Response: (Severity: 3), (Category: IP), (Description: 'Unable to get/read an item from sysDB '), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_0_EGR_Q_ERR_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Egress queue error on NPU-0 interface on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_NETIO-6-DEBUG_REG ### Response: (Severity: 6), (Category: L2), (Description: Debug message registration failed No significant impact on functionality.), (Recommended Action: Could be a system-level issue, please check if there is sufficient memory on the node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-3-INIT_ERROR ### Response: (Severity: 3), (Category: QOS), (Description: The DPA QoS EA module failed to initialize. The System Manager will restart the EA process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_RIB-5-BATCH_ERROR_CODE ### Response: (Severity: 5), (Category: ROUTING), (Description: The specified error was encountered in the OSPF RIB batching code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlea-6-NO_MEM ### Response: (Severity: 6), (Category: L2), (Description: The VLAN EA process was not able to allocate the memory that it needed to complete the operation. VLAN functionality on the affected node may be reduced until the problem is resolved.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-4-IFHANDLE_NULL ### Response: (Severity: 4), (Category: SECURITY), (Description: Error encountered while obtaining handle for the interface specified as the source interface.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DATAPATH_FPGA_API-7-ERR ### Response: (Severity: 7), (Category: L2), (Description: TDatapath FPGA API generated errors.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_TDM-4-OOS ### Response: (Severity: 4), (Category: HA), (Description: A process failed to restore state from a table in the checkpoint store.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-PARTITION_USAGE_NORMAL ### Response: (Severity: 4), (Category: MEDIASVR), (Description: A partition is monitored for critical usage levels. This ios_msg is raised when the monitored partition returns to pre-set normal usage percentage), (Recommended Action: Contact TAC for further support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-3-DIA_PEER_FLUSHQ ### Response: (Severity: 3), (Category: SECURITY), (Description: Queue is more than configured limits. Clearing the pending messages. Check 'show tcp brief' for diameter peer connection.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-PAKBCASTFAIL ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: Packet server failed to broadcast to message to its clients that it is about to restart.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-DEFAULT_ROUTE_FAIL ### Response: (Severity: 4), (Category: INFRA), (Description: XLNCd attempts to set the default route for each network namespace to direct traffic out of the to_xr interface. If the corresponding IOS-XR VRF contains a Management Ethernet interface then an IP address from that interface is chosen as the source hint for the default route. This error indicates that XLNCd encountered an error while trying to set the default route in Linux. The impact is that whatever route previously existed will continue to be used, with the likely impact that traffic over the to_xr interface will be sent with the wrong source IP address. This only impacts traffic sourced by native Linux applications running on the box, but note this may include some management applications such as Model-Driven Telemetry, and IOS-XR software installation. There is no impact on data traffic.), (Recommended Action: Restarting the xlncd process may fix the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-CPU_HOG_2 ### Response: (Severity: 6), (Category: HA), (Description: Wdsysmon has detected a cpu starvation situation - potentially a high priority process spinning in a tight loop.), (Recommended Action: Check the system status, including the saved log for evidence of a high priority cpu hog.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-6-SWITCH_OPERATIONAL ### Response: (Severity: 6), (Category: INFRA), (Description: Informational message indicating that the switch is initialized, configured and fully operations.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-3-COMMS_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: A fatal error was encountered during initialization.), (Recommended Action: If the process does not restart automatically then try manually restarting it. A likely cause for this error is that the system has run out of memory. If this is not an out-of-memory problem and restarting the process does not solve it then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-TX_RX_TIMEOUT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected a timeout on some bus), (Recommended Action: Please try to correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-SYSMGR_CORE_OPTIONS_FAIL ### Response: (Severity: 6), (Category: OS), (Description: Dumper failed to get process core option values from the process init/startup file. Typically because the process doesn't provide its init/startup file, or rarely because dumper shared memory for keeping process core options are corrupted.), (Recommended Action: This is informational message.No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_SW-3-ERR_NO_INTERFACE ### Response: (Severity: 3), (Category: IP), (Description: --), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-4-MUTEX_FAIL ### Response: (Severity: 4), (Category: INFRA), (Description: A system error was encountered when attempting to acquire or release a mutex. In rare circumstances, this may result in unexpected behaviour in the SLA library, incorrect statistics or unexpected restart of the protocol process.), (Recommended Action: If unexpected behaviour is seen, the system may be recovered by restarting the protocol process on the affected node. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA_CAPI_SERVER-3-IOFPGA_PMBUS_INTR ### Response: (Severity: 3), (Category: INFRA), (Description: IOFPGA asserted PMBus interrupt , for exact info view the '%s'i msg displayed.), (Recommended Action: This is a informational message.This indicates Fault with temp sensor or PSU module or Fan controller indicated by syslog message,can be ignored on first occurence . In case of repeated msg contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTR0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-READ_FAILURE ### Response: (Severity: 3), (Category: MGBL), (Description: Read or Write operation not possible as there is an error in associating a stream with a file descriptor.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-CLOCK_CONFIG_NOT_SUPPORTED_IN_HARDWARE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Due to limitations in ASR9000 RSP frequency synchronization hardware, certain combinations of clock-interface config are not supported. If one clock-interface (sync 0 or sync 1) is configured in any of these modes: clock-mode bits-input t1 clock-mode bits-output t1 clock-mode bits-output 6m-output-only then the following configurations for the other clock-interface are prohibited: clock-mode bits-input e1 clock-mode bits-input 2m clock-mode bits-output e1 clock-mode bits-output 2m Note that 'clock-mode dti' is compatible with all other modes; that is, if one clock-interface is configured 'clock-mode dti' then the other clock-interface can have any clock-mode ... including 'dti'. Likewise, 'clock-mode bits-input 64k-input-only' is compatible with all other modes.), (Recommended Action: Do not attempt to configure RSP clock interfaces in mixed T1 and E1 modes. In this context, 'T1 mode' includes '6m-output-only' and 'E1 mode' includes '2m'. The simplest workaround to put your system in a consistent state where a not-mixed-T1-E1 configuration will be accepted is as follows: RP/0/RSP0/CPU0:ios# config RP/0/RSP0/CPU0:ios(config)# clock-interface sync 0 location 0/RSP0/CPUO RP/0/RSP0/CPU0:ios(config-clock-if)# port-parameters RP/0/RSP0/CPU0:ios(config-clk-freqsync)# clock-mode dti RP/0/RSP0/CPU0:ios(config-clk-freqsync)# commit RP/0/RSP0/CPU0:ios(config-clk-freqsync)# root RP/0/RSP0/CPU0:ios(config)# clock-interface sync 1 location 0/RSP0/CPUO RP/0/RSP0/CPU0:ios(config-clock-if)# port-parameters RP/0/RSP0/CPU0:ios(config-clk-freqsync)# clock-mode dti RP/0/RSP0/CPU0:ios(config-clk-freqsync)# commit RP/0/RSP0/CPU0:ios(config-clk-freqsync)# end With both ports in DTI mode, you will be able to change the configuration to fit your requirements.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-MPLS_REG_DROPPED ### Response: (Severity: 3), (Category: ROUTING), (Description: A MPLS registration operation request received when server is not initialized.), (Recommended Action: Controller and/or agent must ensure that MPLS registration operation requests are sent only when server is ready. If message is still seen after meeting these conditions, contact Cisco for support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_PAIRING-3-ERR_SYSDB_ACCESS ### Response: (Severity: 3), (Category: PLATFORM), (Description: The specified SysDB operation failed. Software will automatically do recovery by restarting the drp_paring process.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-FAILURE_MUTEX_INIT ### Response: (Severity: 3), (Category: IP), (Description: The CE-TFTP server process exited due to failure in the Mutex initialisation at the specified API. The process will be respawned.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-2-FPD_EN_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: The FPD process failed due to software unable to set FPD_EN bit.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_FIB-3-INT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message in the SSE FIB to indicate that an internal error was seen when trying to check consistency of internal data structures.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTS1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-4-ASIC_TEMP_NOT_VALID ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_METRO-3-NULL_CONTEXT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Object context does not contain required parent/child context.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: preroute-6-INFO_MSG ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is a Informational message in the preroute manager %s - indicates the informational message. %d - indicates any additiona data.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV6_EA-3-INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An initialization error has occured for IPv6 Forwarding Information Base.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-3-APIV_BIND_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: APIV bind operation failed.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-LDA_AFP_LNK_FAULT_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the transceiver port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. Do transceiver (SFP/XFP/CFP) OIR. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MMAP_PEER-3-MMAP ### Response: (Severity: 3), (Category: OS), (Description: The mmap() failed in mmap_peer_local.), (Recommended Action: Copy the message exactly as it appears, and report it your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE2_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE2_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIO-7-ERR_EDM_INIT ### Response: (Severity: 7), (Category: PLATFORM), (Description: The EIO library was unable to register with sysdb as an EDM. The System should still continue to function as normal, with the exception that the 'show' commands for EIO will not be available.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-2-CONFIG_MISMATCH ### Response: (Severity: 2), (Category: ROUTING), (Description: Max-prefix config with discard-extra-paths option AND soft-reconfig in config with always option both cannot be supported. One of them has to be unconfigured.), (Recommended Action: Remove either Max-prefix OR soft-reconfig in configuration) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cds_proxy-3-EVENT_MANAGER_CREATE ### Response: (Severity: 3), (Category: OS), (Description: Failed to create the event manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-7-VERBOSE_GENERAL ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-UNEXPECTED_ETHER_TAG ### Response: (Severity: 3), (Category: L2), (Description: EVPN received Non-Zero Ethernet tag), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCMCIAD-3-START_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: PCMCIAD failed to come up due to the specified reason.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture console log and 'show sysmgr trace: for possible cause) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_IO-3-PA_BIND ### Response: (Severity: 3), (Category: IP), (Description: The ipv4_io process encountered a software error while connecting to the port arbitrator.), (Recommended Action: IPv4 IO could not register with the PA for handling a particular ICMP type locally. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-FAILURE2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: an external API has failed in Shelf Manager. The details are supplied with the msg.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-5-PORT_CONTROL_REMOVE_CLIENT_SUCCESS ### Response: (Severity: 5), (Category: L2), (Description: Port Access is blocked for the client.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-LOCK_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: A lock operation on shared resource, called by parser failed due to the mentioned error.), (Recommended Action: Collect the output of show logging and inform Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-5-APPS_IMAGE_SIZE_ERR ### Response: (Severity: 5), (Category: L2), (Description: The size of the SPA Application image is too big.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-3-SEND_PLATFORM_INFO_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The platform information sent to Service Engine failed to get processed.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-3-CORRUPTED_HB_REQ_MSG ### Response: (Severity: 3), (Category: PLATFORM), (Description: The heart beat request message from the RSP has an invalid seq number in it. If this error persists, the card could be reset by the RSP.), (Recommended Action: If the issue results in any adverse system behavior please contact your Cisco technical support team after collecting the following information: 1. The console output of the active RSP from user login till the end. Please make sure the above error message(s) are included. 2. (admin)#show install trace mbi-hello location 3. The output of the following CLI commands:) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-CFG_MP_UPDATE_INCONSISTENCY ### Response: (Severity: 3), (Category: L2), (Description: CFM encountered an error while trying to delete and/or create Maintenance Points on the specified interface and retrying the operation has not resolved the problem. This situation could indicate that system resources are low. The operational state of CFM will now be out-of-sync with configuration as some Maintenance Point deletes and/or creates have failed.), (Recommended Action: Restarting the CFM Daemon on the node where the problem has occurred may help to resynchronize the system state. This error may occur as a result of memory exhaustion; attempt to resolve any memory issues before attempting to solve this problem. After system resource issues have been resolved, issue 'process restart cfmd location ' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA_MGR-6-MPA_CONFIG_SHUTDOWN ### Response: (Severity: 6), (Category: PLATFORM), (Description: MPA reload is not possible when it is in config shutdown mode.), (Recommended Action: Apply no hw-module subslot shutdown to power up MPA.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-4-ROUTE_IMPORT_WARN ### Response: (Severity: 4), (Category: IP), (Description: 'The LISP route import limit specified through the ' 'route-import maximum-prefix ' ' configuration has been reached.'), (Recommended Action: 'Use the show lisp {ipv4 | ipv6} ' '[instance-id ] route-import ' 'command to inspect the RIB routes that have been ' 'imported by LISP. Modify the LISP route import ' 'configuration to either import fewer routes or to ' 'increase the imported route limit.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-PROC_KILL_DISABLED ### Response: (Severity: 6), (Category: HA), (Description: wdsysmon process-termination is disabled. A process which meets the kill criteria (either because it's in deadlock, or it's a memory or CPU hog - indicated by the first parameter [%d]) will not be terminated.), (Recommended Action: Collect all logs, especially those from wdsysmon. Also collect output from 'show watchdog trace'. Forward the messages to technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TMPL-5-UNSUPPORTED ### Response: (Severity: 5), (Category: SUBSCRIBER), (Description: Features configured under the dynamic template are not supported for this node, so this feature will not be applied for subscribers hosting on this will not have this feature configuration.), (Recommended Action: No Action is required, this ios message is informational, indicating the subscribers will not be having unsupported configuration) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-4-XCVR_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message provides information about the pluggable tranceiver. Possible causes are not supported speed, autoneg.), (Recommended Action: The message is just for information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-5-INIT_STDBY_PEER_UP_DOWN ### Response: (Severity: 5), (Category: ROUTING), (Description: This is a notice saying that the MSDP Peer UP/DOWN on standby.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_TXM-7-NETIO_UNINIT ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-4-BOARD_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: disable S-16 P1, and S-8 P0 board vmon_shutdown intr due to board issue), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_CLEAR_UNKNOWN_PREFIX ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process received a clear event from RIB for a prefix which it was not tracking.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-RSP_MIXED_VER ### Response: (Severity: 3), (Category: PLATFORM), (Description: Mix of different types of RSP is detected. Running the system in this condition is not allowed.), (Recommended Action: Please correct the condition by replacing the RSP with the same type. RSP type can be viewed via 'show platform' CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How have networking protocols evolved to meet the needs of modern converged networks? ### Response: While early networks used a wide variety of protocols at different layers, modern networks have consolidated primarily around IPv4/IPv6 at layer 3 and Ethernet at layers 1-2. This enables a converged multi-service network infrastructure. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-6-CTRL_ETHER_LINK_EVENT ### Response: (Severity: 6), (Category: DRIVER), (Description: card_mgr has detected link event for interface), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-3-EAP_ATTESTATION_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: Canary stamp verification failed, peer is untrustworthy.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-HW_PROG_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message in FIB platform to indicate that engine layer identified an error while programming an object in h/w.), (Recommended Action: Please collect the console log, show tech-support cef platform. Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-3-PUBLISH_UPDATE ### Response: (Severity: 3), (Category: SERVICES), (Description: An error has occurred while indicating the occurence of the given update to nodes other than that local to the interface indicated. Packet diversion may now be inconsistent. The error string will give more detail on the type of error that has occurred.), (Recommended Action: For non-resource errors, removing and adding back the configuration that prompted the message may remove the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the error is a resource error this will be indicated in the error description given. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-DEBUG_INIT_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Dumper used debugs, so that issues can be debugged.Debug init failed will disable this facility. This has no impact on the core file or functioning of dumper.), (Recommended Action: Does not impact core. Contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SELECTION_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: A new set of inputs has been selected at the specified selection point, to drive the output of the selection point.), (Recommended Action: This message is for information only, no further action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-BADHRCHY ### Response: (Severity: 4), (Category: MGBL), (Description: An invalid hierarchy was entered by the user.), (Recommended Action: Use the 'children' command to progressively find out the correct hierarchy string. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-3-ENQ_PKT_LOGIC_ERROR ### Response: (Severity: 3), (Category: L2), (Description: Egress Queue Manager encountered a ENQ packet logic error. Possible cause for this error condition is a faulty hardware.), (Recommended Action: No action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSU-3-PM_UNDER_PERSISTENT_FAULT ### Response: (Severity: 3), (Category: LIBRARY), (Description: The power module can not recover from persistent fault.), (Recommended Action: Please try manual AC/DC cycle to recover from the fault.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-3-PCIE_RESP_FIFO_MBE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-EXIT_DRVR ### Response: (Severity: 3), (Category: FABRIC), (Description: NPU driver process is exiting due to the mentioned error condition.), (Recommended Action: Verify that the driver will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS_MODULE-2-DEV_OPTICS_COMPLIANCE_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A compliance error was detected during optics module initialization. A compliance error is due to unsupported optics, checksum error, EEPROM CRC error, vendor data error, or decryption error. The optics is the pluggable optics on the line cards. optics initialization may happen when linecard boots up, optics OIR and line card process restart. The optics will not be enabled if an module compliance error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the optics with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR_EA-3-INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Initialization of PBR EA PD DLL has failed due to one of the following reasons: 1) Failed to register with Ltrace. This would prevent process from logging trace messages. 2) Failed to register with debug. This would prevent process from logging debug messages. 3) Failed to initialize Shared Memory. This would prevent process from using shared memory for saving critical info. 4) Failed to initialize Feature EA DLL API needed for programming of hardware resources. 5) Failed to initialize callback function from Feature EA DLL for compiling IPv4/IPv6 TCAM entries needed for Policy programming in hardeare. 6) Failed to initialize feature checkpoint info. This is needed for checkpointing IPv4 and IPv6 Policy programmed in hardware. 7) Failed to initialize TLU connection. This would prevent process from using TLU resources for storing IPv6 Redirect Nexthop. 8) Failed to initialize MIPC connection. This would prevent process from flushing policer entries from RSM to HW. 9) Failed to initialize QoSRM DLL. This would prevent process from allocating a Policer for a Class.), (Recommended Action: No action is required. Process will be restarted. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_IO-6-ERR_GENERAL ### Response: (Severity: 6), (Category: ROUTING), (Description: Some informational message with cerrno.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-4-CDMA_REQ_ERROR ### Response: (Severity: 4), (Category: FABRIC), (Description: CpuCtrl driver was not able to complete the CDMA request for the above specified address location. This may be caused if the device is not initialized correctly or synchronized correctly.), (Recommended Action: If it is possible to isolate the trigger point for the cdma failure, collect all the necessary condition that caused the error. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-LOCKORDER_UPGRADE ### Response: (Severity: 7), (Category: OS), (Description: This is a debug message that is not compiled into a customer version of the code. An invalid upgrade was made of a lock.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-2-MAX_BPORT_REACH ### Response: (Severity: 2), (Category: PLATFORM), (Description: DPA failed to install entry because of Max Bridgeport limit.), (Recommended Action: Please collect the console log, DPA traces (show dpa trace loc <>), The failure could be because we are exceeding limit for max bports in VRRP. Report to your technical support representative for further details.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED_LIB-3-LRD_GET_DLRSC_ERROR ### Response: (Severity: 3), (Category: OS), (Description: A placed client API failed in the call to lrd to get the dlrsc nodeid), (Recommended Action: Collect the function name and traceback information in addition to below show commands and forward to your next level of technical support. show commands: show tech lrd, show redundancy trace, show tech sysmgr, show tech placed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-7-MSG_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Received unexpected message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.=) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-2-AUTO_FPD_RELOAD ### Response: (Severity: 2), (Category: PLATFORM), (Description: These messages indicate that FPD auto-upgrade is successful and the LC is to be reloaded shortly, as some FPDs require reload to get the latest FPD version activated.), (Recommended Action: No action is needed from the user. This is to inform the user about the LC reload initiated after FPD auto-upgrade.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-7-DEBUG_INIT_EVENT ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when initializing debug.), (Recommended Action: Restarting the process may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-3-NO_SOCKETS ### Response: (Severity: 3), (Category: PLATFORM), (Description: No sockets), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOSLIB-4-DLCLOSE ### Response: (Severity: 4), (Category: QOS), (Description: This message is seen when the process fails to close the DLL 'libqos_ea_ui_supp.dll'. It may fail to close the DLL due to any one of the following reasons: 1. Due invalid handle passed to the function. 2. DLL may have been already closed.), (Recommended Action: Please get the information specified under the component required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2RIB-3-MALLOC_FAILED ### Response: (Severity: 3), (Category: L2), (Description: L2RIB couldn't allocate memory.), (Recommended Action: Check memory utilization on the card the error came for and take appropriate steps to reduce it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-MLACP_CORE_ISOLATION ### Response: (Severity: 5), (Category: L2), (Description: Core network connectivity status for the ICCP Group has changed, affecting the bundle. If the bundle is isolated then it cannot be active for MC-LAG.), (Recommended Action: Ensure that the backbone interface is able to carry traffic to the core.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMIB_IFSPECIFIC_CLIENT-3-ERR_OPER_TABLE ### Response: (Severity: 3), (Category: SNMP), (Description: 'A software problem has been detected that prevents SNMP from ' 'completing the requested interface specific table operation. ' 'Operation of the interface specific MIB (e.g. SONET, Ethernet) is ' 'impacted.'), (Recommended Action: 'If this message is encountered, copy the System Message exactly as ' 'it appears on the console or in the system log, contact your Cisco ' 'technical support representative, and provide the representative with ' 'the information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-5-CLOCK_INTERFACE_PORT_3_SENDING_AIS ### Response: (Severity: 5), (Category: PLATFORM), (Description: When no external clock source is available, this status propagates to BITS output ports in T1, J1 and E1 modes. When an external source is qualified, this alarm will be cleared.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-MUTEX_INIT_FAILED ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: The packet subsystem failed to initialize the packet mutex.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: USB-2-DEV_EUSB1_NOT_AVAILABLE ### Response: (Severity: 2), (Category: PLATFORM), (Description: EUSB1 device not available), (Recommended Action: Please attempt the following: If dual RSP, and the problem is on the active RSP, issue 'redundancy switchover' If the problem is on the standby/simplex RSP: Restart low level usb driver via ksh, 'kill io-usb_pid' Failing which, Restart usbstack 'process restart umass-enum' Failing which, Reload RSP If problem persistes, replace EUSB devices If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-OPTICS_FPGA_SERDES_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Rx serdes fault detected/cleared on port), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-3-EMPTY_BIT_NOT_CLEARED_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: I2C operation failed because the EMPTY bit is still set after multiple retries. I2C server process will automatically restart to recover from this error condition.), (Recommended Action: This error should recover automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KIM-2-LOG_EMERG ### Response: (Severity: 2), (Category: INFRA), (Description: please see show kim log for more information.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_6_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_ENCAP_DB-2-TUN_NOTVALID_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: TUNNEL not inserted in AVL tree. valid flag not set), (Recommended Action: The following needs to be collected and DE team to be contacted. show encap-id platform egress-db all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSV_APP-3-PIO_INVALID_PARAM ### Response: (Severity: 3), (Category: L2), (Description: An error occured because acc_stride was greater than acc_size), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_DLL-3-ERR_ASIC_MBE ### Response: (Severity: 3), (Category: FABRIC), (Description: CCSQ encountered a multiple bit error in the mentioned block. This error is an uncorrectable error. Driver takes appropriate action to log and fix the error which may include a device reset.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VASI_MA-3-INTF_CREATE_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: The VASI Manager has failed to create an interface. This can happen primarily due to low memory condition in the system or in some cases due to an internal error.), (Recommended Action: Check the output of show mem summary and look for ways to free up memory and restart the vasimgr process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of Secure Shell (SSH) and how is it configured in Cisco IOS XR? ### Response: Secure Shell (SSH) is used to provide secure and encrypted remote access to the router for management purposes. SSH is configured by generating a key pair, specifying the SSH version, setting the timeout and maximum authentication tries, and configuring VTY lines to use SSH as the transport protocol. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ce_iso-2-FAULTCE_DISABLEPORT28_43 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fault detected while disabling the port because of the failure of disabling functionality. Isolating RP node from the CE network is failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-MIXED_MEMORY_POWERED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Target node is brought up because it is up previously. System operating in mixed line card memory mode, which is only supported temporily during line card upgrade or downgrade.), (Recommended Action: Correct the situation by using line cards with same memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-THREAD_COND_WAIT_FAIL ### Response: (Severity: 7), (Category: OS), (Description: Dumper waits for a condition based on which it triggers the core dump process. Here a thread failed to wait on a conditional variable. It will impact the functioning of dumper process.), (Recommended Action: If this happens while dumping the core, please verify if the core dump is successful or not. Please collect the following data and contact the support. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. follow process ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-NOTIF_Q_FULL ### Response: (Severity: 3), (Category: OS), (Description: Too many notifications have been sent to the component. The queue to hold the notification has overflowed. System will recover by itself. When this issue happens, it will trigger an automatic restart of pifibm_server_lc process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-LABEL_RECLAIM_FAIL ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-NSR_READY_STATE ### Response: (Severity: 5), (Category: ROUTING), (Description: The listed state refers to the state of NSR, which is either 'ready' \ or 'not ready'.), (Recommended Action: None. This is a solicited message (by \ 'logging events sync-updates' . User may verify the NSR sync \ status as shown in the output of \ 'show mpls traffic-eng nsr status detail'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_1_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-3-HBLOSS_SCRIPT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The execution of the heartbeat loss log collection script has failed, and the error code is indicated in the error message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_EXEC-3-ENCODING_ERROR ### Response: (Severity: 3), (Category: L2), (Description: This may be a program level error.), (Recommended Action: Try to rerun the CLI , if it fails again please contact support If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MANSDORF-3-INIT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: A initialization failure occurred in MANSDORF layer. The message string indicates the reason for the failure. Here is a list of possible reasons for this message (not all-inclusive). - Failed in init lteace. This condition indicates a problem with the software when ltrace init failed.), (Recommended Action: Please collect the console log and the CLI output. show logging show running-config show cli history detail loc <> sh plim services trace driver info sh plim services trace driver error show tech-support location <> show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-3-HEALTH_MONITOR_ERROR_MSG ### Response: (Severity: 3), (Category: L2), (Description: NPU driver health monitor detected error conditions), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR node protection desired feature? ### Response: The MPLS TE FRR node protection desired feature allows a TE tunnel to be configured for node protection, but if node protection is not possible, link protection is attempted instead. This provides a best-effort approach to protecting traffic, preferring node protection but using link protection as a fallback. It increases the chances of successful FRR protection. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VRRP-3-ERR_MAX_MAC ### Response: (Severity: 3), (Category: IP), (Description: More than the maximum supported number of MAC address filters has been installed for this interface meaning traffic to some virtual router IP addresses will be dropped. Note that for sub-interfaces the limit is per parent interface.), (Recommended Action: Reduce the number of virtual routers on this interface (or the parent if it is a sub-interface)) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-3-DSP_RECOVERY_NOT_POSSIBLE ### Response: (Severity: 3), (Category: PLATFORM), (Description: One or more interfaces are still UP due to which DSP (Denali) recovery cannot be attempted.), (Recommended Action: Contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-PAUSED_BEFORE_RELOAD ### Response: (Severity: 6), (Category: INSTALL), (Description: When initiating the operation, the user specified that the install infrastructure should pause before doing any reloads. The operation will not continue until the user indicates that it is safe to do so using the supplied command.), (Recommended Action: Either follow the command given, or attach to the operation synchronously for further details.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-4-IPV4_ROUTES_TOO_MANY ### Response: (Severity: 4), (Category: SECURITY), (Description: Spoke sent too many IPV4 routes during negotiation.), (Recommended Action: 'configure spoke with less routes') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the IOS XR System Database (SysDB)? ### Response: SysDB is a centralized in-memory database that provides a consistent view of system state and configuration. It is used by IOS XR processes to store and retrieve config and operational data. SysDB supports high availability by replicating data between nodes. It provides a schema-driven API for processes to access the data. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-MIXED_MEMORY_ALARM ### Response: (Severity: 3), (Category: PLATFORM), (Description: System enters/exits mixed line card memory mode, as a result of powering up or removing a line card of different memory configuration.), (Recommended Action: Correct the situation by using line cards with same memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-RCVD_NOTIF_BADHOLDTIME ### Response: (Severity: 5), (Category: ROUTING), (Description: A BGP notification message of unacceptable hold time has been received.), (Recommended Action: This message is info only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-LISP_RLOC_TBL ### Response: (Severity: 3), (Category: ROUTING), (Description: This reflects a failure in the maintenance of the lisp rloc table used to control lisp decapsulation in the specified VRF.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-3-NOMEMORY ### Response: (Severity: 3), (Category: MGBL), (Description: An operation could not be accomplished because of a low-memory condition.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-COLLECTING_DEBUGS ### Response: (Severity: 4), (Category: PLATFORM), (Description: An error condition was hit causing shelfmgr to collect some debug info via a script.), (Recommended Action: If this error persists, please collect the file shown in the message and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-3-SYSDB_INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: A software error occurred when the ANCP process tried to perform initialization with the system database process/routines. The error could be because sysdb process is unavailable at the time of ANCP initialization or a software error in either of ANCP or sysdb processes.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and if ANCP process is able to initialize and come up successfully after restart, then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_3_LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature less than or equal to the low temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CPAK with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCM_SWITCH-3-THREAD_START_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An internal error occurred in bcm_process which involves exiting the process. After the bcm_process restarts, the error will be cleared.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-6-QDR_BIST_FAILURE ### Response: (Severity: 6), (Category: L2), (Description: Egress Queue Manager encountered a QDR BIST failure error. Possible cause for this error condition is a faulty hardware.), (Recommended Action: No action is required. Process will be automatically restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_6_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_6 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-3-OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in DMAC process. Typically, this is an internal error. Sometimes, it will result in a RSP card reboot. The message string indicates the reason for the failure. This message also provides an error code and a string interpretation of the error code.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers dmac device detail location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers dmac device detail location output, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-3-APIV_MSG_ENCODE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: API Version message encoding failed.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-MEM_SIZE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: CPP driver failed to acquire the size of a block of memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-6-TRIGGER_SO ### Response: (Severity: 6), (Category: ROUTING), (Description: If NSR switch-over is configured, active bgp will trigger the switch over in case of TCP failure or BGP failure, if NSR is ready and an install operation is not in progress.), (Recommended Action: This message is for information purpose only. Analysis should be done if switch-over is not expected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-3-HEALTH_MONITOR_ERROR_MSG ### Response: (Severity: 3), (Category: L2), (Description: PSE driver health monitor detected error conditions), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Collect the error message) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_1_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you deactivate a software package in Cisco IOS XR? ### Response: A software package can be deactivated in Cisco IOS XR using the 'install deactivate' command, which disables the package's features on the router without removing the package. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-MMAP_IMDR_FAIL ### Response: (Severity: 3), (Category: OS), (Description: mmap of the shared memory required to store servers tree nodes failed during IMDR.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture 'show shmwin summary', 'show shmwin trace server', and 'show shmwin trace all'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_VPLS-6-AGE_TIMER_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: MAC aging time is set to this new value, which is highest among all bridge-domains.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-6-NO_BUF_TO_REPLACE ### Response: (Severity: 6), (Category: PLATFORM), (Description: CPUCTRL RX PDMA ring could not replace the buffers. possible low buffer condition.), (Recommended Action: Check for packet memory particle allocation and usage with 'show packet-memory', 'show packet-memory inuse' and 'show packet-memory old'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_NEXTHOP_UNREGISTER ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process failed unexpectedly to unregister a next-hop resolution event. Future state change events on the next-hop may cause further messages to be generated by the static process.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-NSF_CREATE_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: TBD.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_TNC ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from TNC.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-2-ENFORCE_OOC ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature is enabled without appropriate licenses.), (Recommended Action: The customer should either purchase more licenses or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ST16550-3-MUTEX_UNLOCK_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The ST16550 UART driver has been unable to unlock access to the UART.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-SHIP_PERF_ITEMGET_FAIL ### Response: (Severity: 7), (Category: SYSDB), (Description: Registering performance counter with stats infra failed.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-BPM_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred while initializing the BGP process manager. If this occurred during process startup or RP Switchover, then the process may be restarted.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-PKT_LEN_ERR_1_XAUI_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet length error - 1 from XAUI on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMDR-5-CLIENT_INIT_DEBUG_FAILED ### Response: (Severity: 5), (Category: OS), (Description: 'Debug utility registration failed.' 'Debug functionality may not work properly.' 'IMDR will proceed without fail.'), (Recommended Action: 'Restarting the process may resolve the issue.' 'If the problem persists after some tries, contact tac.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_APS-6-CONTACT ### Response: (Severity: 6), (Category: L2), (Description: Debug messages for APS.), (Recommended Action: No Action requirements.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-7-POLICY_ITEM_UNSUPPORTED ### Response: (Severity: 7), (Category: ROUTING), (Description: The policy_repository process was not able to extract the the item for this type. Please add support to the policy_repository or remove support from the protocols.), (Recommended Action: This indicates and internal inconsistency between the policy_repository and the protocols. Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-OPEN ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to open() failed. The error is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA-3-MGII_MUTEX ### Response: (Severity: 3), (Category: IP), (Description: Failure of thread operations on the mutex protecting the multicast group memberships.), (Recommended Action: Do the following action.Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-LOW_TEMP ### Response: (Severity: 3), (Category: FABRIC), (Description: The POD detects a low temperature. The POD might not be functioning properly, and can cause cell drops or corruption in the rx or tx link associated with the POD.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCM-2-INTERNAL_ERR ### Response: (Severity: 2), (Category: L2), (Description: Internal error. Type of error and reason will be there in the msg %s - ifhandle/ name of errored interface %s - Type of the error occured %s - Reason for the error This happens on the LC with ATM interfaces), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Most of the errors are because of low memory. Others are not very critical. LC reload will resolve the low memory condition. Information to be collected before the reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NACMD-7-INIT_FAIL ### Response: (Severity: 7), (Category: SECURITY), (Description: Error encountered while using the System Database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ROULETTE-3-OBFL_CACHE_OVERFLOW ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message related to the Canbus Controller processing the received UART message.), (Recommended Action: restart canb-server.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCASTSN_POLICY-3-ORA_INSTBUILD ### Response: (Severity: 3), (Category: L2), (Description: Internal error in the routing policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp snooping trace error verbose command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp snooping trace error verbose output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG_HIST_UPDATE-3-TUPLE_LOCK_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: Internal error), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-3-LDP_CTX_INIT_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: During LDP [vrf] context creation, the initialization of some of the module has failed. This is a severe condition and results in LDP to go non-operational state for given VRF (or default VRF).), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. A user can also try restarting 'mpls_ldp' process (after collecting required info) to fix this issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-3-CHAN_CONNECT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This error message indicates that there is a failure to connect lwm server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET-3-MAC_ACC_STATS_REGISTRATION ### Response: (Severity: 3), (Category: L2), (Description: It was not possible to register for statistics collection due to a error reported by the statistics infrastructure.), (Recommended Action: If the error is reported again then reloading the linecard may allow it to recover, but it will impact all traffic on that node. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_8_LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICLIB-4-NO_APP_MEDIA ### Response: (Severity: 4), (Category: LICENSE), (Description: The disk utilities library did not return a device name to license manager where the persistent license data files can be stored. License information will be stored in a temporary location, and will be lost if the router reloads. Implicit licenses will be available. Permanent or evaluation licenses should not be installed in this state, as they will be lost if the router reloads and will need to be regenerated before they can be installed again.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-5-CCM_ERROR_COUNTER_WRAPPED ### Response: (Severity: 5), (Category: L2), (Description: The CCM error counters displayed in 'show ethernet cfm peer meps' are only able to store a value of up to 4294967295. One or more of the error counters have gone over this limit and the counter has wrapped around to zero.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to verify disk synchronization for disk mirroring? ### Response: To verify disk synchronization for disk mirroring, ensuring data integrity, use the 'mirror verify' command in EXEC or administration EXEC mode. RP/0/RSP0/CPU0:router#mirror verify <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STANDBY-6-INFO_REDIRECTS_DISABLED ### Response: (Severity: 6), (Category: IP), (Description: Disabling HSRP filtered ICMP redirects when ICMP redirects are enabled may cause hosts to use real IP addresses as their default routes, and first hop redundancy may be lost.), (Recommended Action: Ensure that ICMP redirects are disabled on this interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: PLATFORM FIB, Information), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBMIRROR-3-ERR_NOSPACE ### Response: (Severity: 3), (Category: MGBL), (Description: Note that while a command like df may show free space, rsync creates tmp files during the transfer which may rapidly fill up that free space.), (Recommended Action: Move large files to another directory/filesystem which has more space, and/or clean up junk files you no longer need) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-INVALIDVERSION ### Response: (Severity: 3), (Category: MGBL), (Description: 'The version of this file is too old or wrong'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-3-UPGRADE_PROV_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cannot do FPD upgrade when Provisioning is in progress. Upgrade to be initiated again after provisioning), (Recommended Action: Issue FPD upgrade command again once provisioning is completed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-4-SET_THREAD_PRIORITY ### Response: (Severity: 4), (Category: PLATFORM), (Description: Unable to set the heartbeat pulse of this node to high priority. Proceeding with default priority, however in a high CPU consumption, this node's heartbeat pulse may get lost, causing this node to get reloaded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-5-PLL_T0_STATE_FREERUN ### Response: (Severity: 5), (Category: PLATFORM), (Description: No external reference frequency is available for synchronization, so the T0 PLL output is free-running.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-4-FABRIC_FAILURE ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message provides information about the fault occurred on the interface.), (Recommended Action: The message is just for information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_NETIO-4-PAK_DROP ### Response: (Severity: 4), (Category: L2), (Description: The PPP NetIO DLL has been forced to drop a packet because of an unexpected error. The error message describes the reason for the drop.), (Recommended Action: The system may recover by itself. If it doesn't then the error message will recur. In this case consider restarting the NetIO process on the affected linecard. If the error messages continue after restarting NetIO then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MGID_ERROR-3-CHKPT_TRAN ### Response: (Severity: 3), (Category: PLATFORM), (Description: Version upgrade from one version to another failed. Traffic loss is expected till database is rebuilt.), (Recommended Action: Wait for the database to rebuild.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_RIB-3-ERR_UPDATE_COMPLETE ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered in the call to ipv6_rib_update_complete.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBCSVI_BILLING-5-PATHSTATUS ### Response: (Severity: 5), (Category: SERVICES), (Description: The SBC billing cache path mount point status has changed and is being reported to the user for an easier access to the SBC billing records.), (Recommended Action: Take note of the paths used by SBC billing to access the SBC billing records) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_MODULATOR_BIAS ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_BEFORE_TRACE ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA encountered an error initializing its Debug and Trace The error message describes what operation has failed and why it failed. This is a fatal error and the PPPoE MA process cannot continue. It will abort and subsequently be restarted by SysMgr in an attempt to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BOOTVAR-4-CERR_REGISTER_DLL ### Response: (Severity: 4), (Category: INSTALL), (Description: The error services failed to register the errors of the specified DLL. The system will continue to operate, but error or warning messages displayed to the customer may not be complete.), (Recommended Action: This only impacts ltrace message logging and has no impact on the functionality of the system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Encounter problem during process initialization. '%s' contains the explanation of the problem. %s - error description %d - error code %s - error code description), (Recommended Action: Restart the fabio_svr process. Contact TAC if problem still exist) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-EVENT_ATTACH ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to attach nvgen requst handler to event manager failed. The error is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure RSVP interface priority? ### Response: To configure RSVP interface priority, use the 'mpls traffic-eng priority' command in interface configuration mode. RP/0/RSP0/CPU0:router(config-if)#mpls traffic-eng priority 3 3 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-LAYER_ERR ### Response: (Severity: 3), (Category: L2), (Description: Check of HW layer failed. You are trying to create/edit logical switch, but it is already registered in sysdb and its layer value (layer2 or layer3) is diffent than requested one. *SUPPORT*), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-DEFAULT_ROUTE_CREATE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: A route update was skipped because of an internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_MPLS_EA-3-COMMUNICATION_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A communication error has occurred in the MPLS Forwarding Information Base.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-3-ERR_MUTEX_LOCK ### Response: (Severity: 3), (Category: L2), (Description: Locking the mutex governing the access to MFR MA IDB database failed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOMAIN_SYNC-3-SYNC_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Error in syncing the given XR configuration to Linux), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-ERR_LOOKUP ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected lookup error occured when trying to lookup a prefix.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-BAG_ENCODE_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to encode a bag.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_FPD-3-UPDATE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The update operation for the specified FPD image has failed.), (Recommended Action: Retry the operation to update the image. If the retry operation fails, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFL-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an information log.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-ASIC_ERROR_DIGI_CPAK ### Response: (Severity: 3), (Category: OS), (Description: An unexpected error occurred.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-SNMP_IDX_REL ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occurred while releasing an SNMP index. This may be due to an internal programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPG-7-FAST_BAG_DECODE_FN_CREATION_FAILURE ### Response: (Severity: 7), (Category: MGBL), (Description: Failed to create a fast bag decoder. The generic decoder will be used instead.), (Recommended Action: No action is required. This is an internal message used to track and improve efficiency of the system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_INT_PWR_SUPPLY_ALARM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ROULETTE-6-UPGRADE_COMPLETED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message indicating that Canbus Controller firmware upgrade is completed on the specified location.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_DRV-3-ERR_PHY_MEM ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in platform component,due to platform_get_reserved_physmem function invocation failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-5-BAD_PKT_RCV ### Response: (Severity: 5), (Category: IP), (Description: A packet was received from the network which was not properly formatted. As a result, the packet was discarded. If the packet was destined to an existing neighbor connection, the connection remains intact unless the dead timer to our peer expires.), (Recommended Action: First, determine if the problem is persistent. If it is, perhaps the router is communicating with a non-conforming or mis-behaving ANCP client. ANCP's detail summary statistics will show the number of occurrences and what was invalid in the packet. If the packet was received on an existing adjacency, the drop statistics will reveal which adjacency the drop occurred on. Details error logs can also be found in ancp neighbor trace. If the device is identified, restart or remove it from the network. If a device is not identified, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-FIA2NPU_0_PKT_MINLEN_ERR_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet minimum length error on FIA to NPU-0 interface on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-3-DSP_HW_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: DSP hardware failure reported), (Recommended Action: Contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-2-ASIC_ERROR_THRESHOLD_CARD_SHUTDOWN ### Response: (Severity: 2), (Category: PLATFORM), (Description: Uncorrectable asic errors occured on card), (Recommended Action: ASIC errors that are uncorrectable have occured and exceed the threshold. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_HEAP-7-PROC_RUNNING ### Response: (Severity: 7), (Category: HA), (Description: A request to move or copy checkpoint data from one node to another has failed because an instance of the process is running on the destination node.), (Recommended Action: Determine why the process is running on the destination node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-LDA_DEV_VERSION_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver version is not compatible with the hardware version.), (Recommended Action: Upgrade the FPGA/CPLD image for the device using the FPD procedure, followed by reloading the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-3-RULES_DUPLICATE_FEATURE_STR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The ma-feature or ea-feature property was set twice within a rule. This property may have been set implicitly by the feature or owner-string properties. feature and owner-string are synonyms which set both the ma-feature and ea-feature properties. Please check the rules file.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-PTHREAD_CREATE ### Response: (Severity: 3), (Category: OS), (Description: PlaceD daemon was unable to create the thread. Recovery occurs with automatic process restart.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-CCB_NODEID_CREATION_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that Shelf Manager failed to create a nodeid based on the supplied rack, slot, and instance.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_LOL_MAPPERD ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEMA-3-UNSUPPORTED_ERR ### Response: (Severity: 3), (Category: L2), (Description: A request was made for information on a feature that is unsupported on the device specified in the request. This error may affect the usability of the device if the feature is necessary for proper operation.), (Recommended Action: Check to see if the device on which the feature has failed is performing correctly for all necessary functionality.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-GST_JUMP_ERR_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: GST jump error on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-ORA_RUN ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error in the routing policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-FPGA_PCI_FATAL_AER ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-4-PEC_SWITCHCLOSED ### Response: (Severity: 4), (Category: PLATFORM), (Description: The inserted expansion card screwed in complete.), (Recommended Action: PEC card is screwed in. Enough power should be available for Power On.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-1-ALL_FABRIC_RACKS_LOST ### Response: (Severity: 1), (Category: PLATFORM), (Description: This node has lost connectivity with all fabric racks before the fabric planes came up. This could be a control ethernet problem or the fabrics have reloaded.), (Recommended Action: Check if fabric chassis are up. If up, check control-ethernet connectivity between this chassis and Fabric chassis. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-4-FINT_MEDIA_REG_FAILED ### Response: (Severity: 4), (Category: OS), (Description: LPTS media registration with FINT failed), (Recommended Action: Try restarting the netio process. This could sometimes help fix the problem as the set mapping will be trigged again and we might not hit the failure the 2nd time.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-6-RESET_SELF ### Response: (Severity: 6), (Category: PLATFORM), (Description: The node on which reddrv is running, resets itself on loss of heartbeat from the RP.), (Recommended Action: Check the RP in the system. If present, check the connectivity between RP and the node that went down.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_SYSDB_BIND ### Response: (Severity: 7), (Category: FABRIC), (Description: Ingressq Sysdb Bind error. The driver should retry by itself.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM-3-TLV_DECODE ### Response: (Severity: 3), (Category: IP), (Description: This is an internal error. It indicates that an address information structure couldn't be decoded correctly. This could leave the affected process in an inconsistent state.), (Recommended Action: Get the output of show tech-support, show arm [ipv4/ipv6] trace, running coredump of the process. Unconfiguring, reconfiguring the interface may help in recovering the from error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-5-UNABLE_TO_START_UMASS_DISK_MONITOR_THREAD ### Response: (Severity: 5), (Category: PLATFORM), (Description: platform umass check disk interface called by enum-umass code to allow PD to check on mandatory devices and take platform specific action if missing.Start disk space monitoring for nodes which need. This notice message will get printed when it unable to start umass disk monitor thread.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_INTF_INJ_CAP_DLL-3-LTRACE_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The ltrace file could not be created.), (Recommended Action: Please contact TAC Support Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an L2VPN service instance on an interface? ### Response: To configure an L2VPN service instance on an interface, use the 'service instance' command within the interface configuration mode. interface GigabitEthernet0/0/0 service instance 100 ethernet encapsulation dot1q 100 xconnect 10.1.1.2 100 encapsulation mpls <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-REPLACE_COMMIT_PENDING ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that the entire system will be reloaded as part of the specified install operation and install commit will be triggered post reload.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-2-TRANSCEIVER_LOC ### Response: (Severity: 2), (Category: L2), (Description: The Transceiver location is displayed for both supported and unsupported sfp/xfp types for the following actions - OIR of SFP/XFP - Soft and Hard OIR of SPA/LC - unshut of SPA - Enabling power for LC), (Recommended Action: No actions are required as this is just an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-INVALID_SYMLINKS_FILE ### Response: (Severity: 3), (Category: OS), (Description: A startup configuration file for QSM contained an invalid line. This could be due to a problem with the installed media or file system damage. QSM will continue startup-up, but some system functionality may be impared.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-PURGE_TIMER_ALLOC ### Response: (Severity: 3), (Category: ROUTING), (Description: Couldn't allocate a purge timer. Old routes for this protocol may not automatically get purge from the FIB table.), (Recommended Action: Free up some resources and restart the RIB. *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: d1qnetio-4-TERM_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The software forwarding support for IEEE802.1Q VLANs was unable to clean up. Forwarding should not be affected.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_SYSLOG_PRX-6-INFO_GENERAL ### Response: (Severity: 6), (Category: SECURITY), (Description: The sshd encountered some problem in genric nature or plain information.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-ASIC_FATAL_FAULT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter ASIC hit fatal fault. Card would be reloaded.), (Recommended Action: Fabric arbiter asic hit fatal fault. The card would get reloaded. If the error message persists after reload contact TAC. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the instdir-cli process in IOS XR installation? ### Response: The instdir-cli process provides the user interface for performing installation-related tasks. It allows the user to execute install commands from the CLI. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_RIB-3-DEFAULT_REG ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred on a request to have the RIB send us route updates for the default route.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_28 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHDLC_MA-4-ERR_PKT_HANDLER ### Response: (Severity: 4), (Category: L2), (Description: A failure occured whilst handling a packet event.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of BGP route dampening? ### Response: Route dampening minimizes the propagation of flapping routes across an internetwork. Criteria can be defined to identify poorly behaved routes which are suppressed. Dampening parameters include a penalty value, a suppression limit, a reuse limit, and a maximum suppress time. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_OC3_OC12-6-INFO ### Response: (Severity: 6), (Category: L2), (Description: information message %s - message), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-ERR_THREAD_FN ### Response: (Severity: 3), (Category: SECURITY), (Description: The call to pthread functions, such as pthread_create, lock/unlock a mutex or wait on a condition, failed. The error is displayed in the message.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-UNBIND_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Event manager Connection closure failed.' 'This will not effect the process.' 'This operation is optional'), (Recommended Action: 'ISSU manager will use some other API' 'If the issue persists ' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO_API-3-AIB_SHM_OPEN_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'while creating Shared memory to store AIB entries during initialization.' 'shm open failed.Process will exit with failure'), (Recommended Action: 'Retry the issu operation.If error persists.' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN-3-INVALID_LOGIN_DEBUG_FLAG ### Response: (Severity: 3), (Category: SECURITY), (Description: The debug flag specified is not supported.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-PLR_CONFIG_OUT_OF_SYNC ### Response: (Severity: 3), (Category: LICENSE), (Description: Smart Licensing Configuration does not match the value of the PLR enable flag in Trusted Store. This can happen if a configuration is copied onto the system and a reload occurs. If the new configuration does not contain the Smart Licensing Enable command, the value in Trusted Store will not match.), (Recommended Action: Apply the desired Smart Licensing PLR Configuration Command and persist the configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-7-SVR_MEMINFO ### Response: (Severity: 7), (Category: HA), (Description: An internal error was detected when trying to communicate with wdsysmon to retrieve a node's memory information.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP AS override feature? ### Response: The BGP AS override feature allows a router to override the AS number of a site with its own AS number when sending updates. This is commonly used when a customer is multi-homed to the same provider to avoid the provider's AS appearing in the AS path. It is enabled with the neighbor as-override command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB_ALARM-3-MAC_LEARN ### Response: (Severity: 3), (Category: PLATFORM), (Description: The maximum number of MAC addresses have been learned to a physical limit), (Recommended Action: Reduce number of MAC addresses, or reduce age-out time of stale MACs) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-6-FIRMWARE_MAX_PEMS_IN_UPGRADE ### Response: (Severity: 6), (Category: PLATFORM), (Description: 'Firmware upgrade proceeding with multiple power supplies'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_SDFEC_LOM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_SOCK-4-ERR_PAKMAN ### Response: (Severity: 4), (Category: L2), (Description: An unknown error occurred after a pakman disconnect event. Restarting the socket process should have resolved the problem.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-4-DUAL_HEAD_CONFLICT ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: It has been detected that the configuration applied on the active and standby hosts is not consistent on the Satellite.), (Recommended Action: Run 'show nv satellite dual-head conflict' to display the conflicting configuration. should be in the range 100-65534 and is specified in the message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BPE-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: BPE Driver encountered a fatal error and is not able to recover. The supplied text string will explain the reason. Call support with this text.), (Recommended Action: Please attempt to correct the error by restarting the process by issuing the command in exec mode If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-0-SOFT_ERROR_RELOAD_RECOVERY_0 ### Response: (Severity: 0), (Category: PLATFORM), (Description: Soft error detected on Bridge FGPA instance 0. Card will be reloaded to cover from this error.), (Recommended Action: Soft error are very rare due to Cosmic and other environmental factors. The probability of soft error on same device again is extremely low. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-3-LCFG_DELETE ### Response: (Severity: 3), (Category: SERVICES), (Description: An error has occurred while removing the diversion implemented for the given interface. The error string will give more detail on the type of error that has occurred.), (Recommended Action: For non-resource errors, adding and removing a service attachment for the interface indicated in the message may remove the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the error is a resource error this will be indicated in the error description given. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-TM_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: The asic traffic manager initialization failed due to the above mentioned error.), (Recommended Action: Collect all the event logs and the output of the following commands executed from the CLI of the active RP: 1. 'show process npu_drvr location ' 2. Collect the Broadcom ltraces: pkg/bin/npu_show_ltrace -S If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPDRIVER-3-SERDES_DMEM_MULTIPLE_BIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that during initialization the SERDES SPICO for the indicated ring, NP and serdes instance had uncorrectable bit errors in data memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_SYSDB_BAG_FREE_INDIRECTIONS ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-7-FAIL_EDM_CREATE ### Response: (Severity: 7), (Category: PLATFORM), (Description: Inventory Manager is not able to create a EDM connection with the event manager to populate the inventory details in to the SYSDB database. As a reason it is not able to resgiter for notification/verification from SYSDB.), (Recommended Action: No action needed. Inventory Manager process will restart automatically) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-2-LC_EOBC_FAILED_RSP1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: This line card has lost EOBC heartbeat to RSP1.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_TOPAZ-7-ERR_THREAD_ATTRIBUTE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while setting the thread attribute during the process initialization sequence. This is crucial for the process and is automatically restarted on this failure.), (Recommended Action: If the problem is experienced only by this process in the system, restart the fabric server process by executing the following command at the CLI of the active RP: process restart fab_svr location If problem either persists (following a process restart) or also noticed on other processes then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-IN_MEM_ERROR_LNK4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected an input memory error on link 4), (Recommended Action: This alarm is transient and should auto-clear when error condition is resolved. If the alarm doesn't clear, then please reload the card using command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-OP_SFP_WARN ### Response: (Severity: 4), (Category: PLATFORM), (Description: The particular operation mentioned in the message occured due to some reason. This may be a serious failure, however process may continue functioning as expected (or successfully retry) despite the failure.), (Recommended Action: Collect the outputs for the following CLI : show inventory show diag show controller the various causes for the message are : -Unable to get XFP/CFP/QSFP Vendor name -Unable to get XFP/CFP/QSFP Vendor serial number -Unable to check XFP/CFP/QSFP compliance -Unable to check XFP/CFP/QSFP supported -Unable to get SFP/XFP/QSFP data Action needs to be taken accordingly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_UNEXPECTED_CB ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA received an asynchronous callback from another process when the session was in an incorrect state. The error message describes which callback was received. This is most likely to be a programming error, either in PPPoE or in one of the processes it interacts with.), (Recommended Action: PPPoE MA should recover by itself.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rspp_rio_netio-3-INIT_DEBUG ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of debug for the service ingress diversion NetIO DLL. If this occurred during an upgrade operation then it will cause the NetIO process to reload. Otherwise this will cause the capsulation to be unloaded,and an error will be returned to the user.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_HFR-7-ERR_HEARTBEAT_FSM_STATE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server heartbeat monitoring mechanism detected a problem in the internal state machine.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTREPL-7-FILE_OPEN_FAILED ### Response: (Severity: 7), (Category: INSTALL), (Description: A file could not be opened from this node when as a file stream was being constructed.), (Recommended Action: Run 'install verify packages repair' on RP and DRP nodes.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: S2681-3-SCHEDPARAM_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The S2681 UART driver was unable to set the parameters of the interrupt handler.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_ENA-3-FILE ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP ENA filesystem handler was unable to carry out an operation on an internal file. The HTTP process may no longer be able to function correctly, and may need restarting if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-CONFIG_UNDEFINED_POLICER ### Response: (Severity: 3), (Category: OS), (Description: An input flow definition references an undefined policer. The flow will be configured to use policer 0.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-INSTALL_RESUMED ### Response: (Severity: 6), (Category: INSTALL), (Description: The install operation has been resumed after pausing for user input.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-3-BDXC_CERR ### Response: (Severity: 3), (Category: L2), (Description: This L2FIB error has occurred due to errors in BDXC (Bridge Domain Cross-connect) operations.), (Recommended Action: Check the MMRP/IGMP client status to ensure it is working correctly. If not restart the process using: process restart l2fib_mgr Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-TMC_CLUSTER_PARITY ### Response: (Severity: 0), (Category: PLATFORM), (Description: A parity error interrupt), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-VCPU_INVALID ### Response: (Severity: 3), (Category: OS), (Description: The virtual service machine definition file is requesting invalid VCPU value.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-5-SELFMANAGE_CALLBACK_FAILED ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: NetIO gets restarted if a NetIO DLL fails to process an install event. This should not cause any problems to the router and NetIO should come back up fine after restart.), (Recommended Action: This should not cause any problems in the router, NetIO should restart and come back up fine & resume its normal functionality. If it causes any routing issues such as adjacency going down or some other problem, one potential cause is that NetIO took longer to restart. NetIO restart time is a function of number of interfaces configured in NetIO on this node. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-BAD_LWM_MSG ### Response: (Severity: 7), (Category: OS), (Description: An error was received while processing a request from a local process. There could be a version mis-match or corruption in the client process. The error message should provide some clue to the problem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: Multilink-3-ML_GROUP_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: The link addition/removal from a Multilink bundle has failed due to a software error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-ERR_RSI ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected RSI error occured during a table creation/deletion/modification operation.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-SCRIPT_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: A problem was encountered while trying to spawn a script.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_SW-3-NEED_SLOW_ROUTINE ### Response: (Severity: 3), (Category: IP), (Description: The IPv6 base header in the packet could not be directly accessed in the named routine, and hence the packet was dropped. This is due to the packet not being within the first particle or the header not being completly contained within one particle. If the slow switching routines (using pak_netio_ API calls) had been compiled in then the packet could have been switched.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SDS_LIB-4-INTERNALERR ### Response: (Severity: 4), (Category: INSTALL), (Description: An internal software error occurred while getting the SDS node id.), (Recommended Action: This internal error will be recovered automatically. No user action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-3-IDP_INTENT_FILE_ERROR ### Response: (Severity: 3), (Category: SERVICES), (Description: 'The Intent Distribution Protocol Module, ' 'encountered file error when reading from intent file, ' 'check the file name and its contents'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR-6-UNKNOWN_PACKET_OFFSET ### Response: (Severity: 6), (Category: PLATFORM), (Description: Unknown packet offset passed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ROULETTE-6-UPGRADE_IN_PROGRESS ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message indicating that Canbus Controller firmware upgrade is in progress on the specified location. The page that is being presently upgraded is mentioned in the message. This page number would be in the specified range, corresponding to the Canbus Controller partition that is being upgraded.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_1_LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature less than or equal to the low temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_MA-7-INIT ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_SPP-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: PLATFORM), (Description: HFR SPP Memory Allocation Error message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn spp process, up to a fixed number of times the error is encountered, to recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_EVC_CREATE ### Response: (Severity: 4), (Category: L2), (Description: SSRP failed to create a connection to an essential service during initialization. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCI_SSTAR-3-ERR_INTERRUPT_THREAD_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cpuctrl (sstar) driver detected a critical failure in the interrupt thread initialization. Abort and exit the thread.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-NODE_OIRED ### Response: (Severity: 6), (Category: FABRIC), (Description: In interrupt detecting OIR of the fabric card was received. Driver will exit. If the message is seen at steady state with no OIR action then support should be requested. In case the card was physically OIRed this message may be seen and is not an issue.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_IPV6_EA-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Typically, this is an error where the software fails during initialization. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid during initialization. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware during initialization/ configuration.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show cef ipv6 location <> show cef ipv6 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_PERSIST ### Response: (Severity: 1), (Category: PLATFORM), (Description: An ASIC error has occured and been handled.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-BA_UNSPEC_FAIL_1 ### Response: (Severity: 3), (Category: IP), (Description: The received PBU matches an existing binding that is currently being revoked. Hence this PBU will not be accepted.), (Recommended Action: No action is required. Most likely the binding will be retried from the MAG.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REPLICATOR-7-WRITE_CTX_INVALID ### Response: (Severity: 7), (Category: LIBRARY), (Description: Consumer could not process write from producer. It could be because of invalid/unexisting context. This commonly occurs during issu.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-NT_SWO_PCIE_SWITCH_EEP_UPGRADE_REQD ### Response: (Severity: 3), (Category: INFRA), (Description: The PCIe Switch on the Switch Card does not have the right EEPROM version required, without which the PCIe switch is not correctly setup when the switch card is powered on. This will impact the ability provide Switch redundancy during Shelf Controller card Failover.), (Recommended Action: Upgrade the PCIe Switch EEPROM on the Switch card as soon possible and power cycle the card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-3-PLATFORM_ERROR_RESTART_REQUIRED ### Response: (Severity: 3), (Category: OS), (Description: The Linux Packet classifier hit a fatal error while attempting to register with the platform code. SPP will restart to recover. While the process is restarting all packets processed in software will be dropped, but hardware forwarding will not be affected.), (Recommended Action: If the message is not seen again then the restart resolved the problem and no further action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-5-SINGLE_FEED_NO_EFFECT ### Response: (Severity: 5), (Category: PLATFORM), (Description: 'Warning message that single feed mode was configured on a V1 or V2 AC power modules chassis, the configuration has no effect'), (Recommended Action: Informational, no action needs to be taken) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-GENCOMMERR ### Response: (Severity: 3), (Category: ROUTING), (Description: A Inter Process Communication error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_EA-3-UNABLE_TO_RECONNECT ### Response: (Severity: 3), (Category: SERVICES), (Description: If the Service Infrastructure becomes out of sync with IM, then it reconnects in order to prompt a resync. If this message is displayed then it has been able to reconnect. This may cause configured interfaces to no longer forward traffic, or interfaces which have been shut down or deleted to continue to do so.), (Recommended Action: Restarting the process that displayed the message may solve the issue, or restarting ifmgr. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROL_DRIVER-0-RP_RELOAD_REQUIRED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_400G_POD-3-ERR_INTERNAL_SW ### Response: (Severity: 3), (Category: FABRIC), (Description: The 400G fabric POD DLL encountered the annunciated internal SW error. It likely affects the operation of the fabric POD and the fabric subsystem on the multi-chassis.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TOMAHAWK-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Tomahawk RP CPU Subsystem error reports), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-3-ERR_MISSING_SERIAL_NUMBER ### Response: (Severity: 3), (Category: TOPOLOGY), (Description: Mandatory information serial number is missing.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-6-PLANE_GROUP_UNREACHABLE ### Response: (Severity: 6), (Category: FABRIC), (Description: This message gives additional information related to a plane in multicast-down state. It reports that a group of fabric addresses have become unreachable. For CRS-1 16-slot chassis, group 0 is the upper shelf containing line cards 0 to 7. Group 1 is the lower shelf containing line cards 8 to 15 and both RPs. The message reports the number of data links that are operating from the fabric plane to the specified group. The threshold is the number of data links that should be operating in order to make the fabric group reachable.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-MACH_PARSE_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: The named virtual service has an invalid parameter specified in the .xml file inside the .ova package.), (Recommended Action: Fix the .xml file inside the .ova package to have valid values. Then retry installing and activating it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-6-STATE ### Response: (Severity: 6), (Category: MGBL), (Description: An change state occurred in the tacacsd.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-ERR_ECM_OPEN ### Response: (Severity: 3), (Category: FABRIC), (Description: NPU driver failed to open the event connection manager during the driver initialization. The driver will be non-operational due to this error.), (Recommended Action: The driver will escalate the error to the Fault Management (FM) entity for further action. Verify that the driver will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-4-SESSION_NOT_STARTED ### Response: (Severity: 4), (Category: L2), (Description: The platform failed to start a loopback session when requested to do so during a resync.), (Recommended Action: If any problems are seen, they may be rectified by restarting the edpl_ma process using the following command: - process restart edpl_ma) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-RACK_DOWN_NOTIF_SEND_FAILURE ### Response: (Severity: 4), (Category: PLATFORM), (Description: The reason should be supplied in the IOS message itself, but basically this message means that shelfmgr unable to send the rack down notification), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_LOSS_OF_CHANNEL ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERR_INFO_OPER ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, operational error information), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>), 'show install active', 'show logging console', 'show platform' and 'show version'. Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HBAGENT-7-RELOAD_NOTIFICATION_TEST ### Response: (Severity: 7), (Category: PLATFORM), (Description: The node received a test reload notification just to check functionality. The notification is ignored.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HARDDISK-7-UNKNOWN_MACHINE ### Response: (Severity: 7), (Category: MEDIA), (Description: To derive the MODULE TYPE get the hardware board type ,the module processor type and revision number of the board and of the module. PLATFORM_GET_HW_BOARD_TYPE_REVISION fails when it unable to find the machine type.), (Recommended Action: 'Check EEPROM programmed correctly and also check whether it is cisco supported router ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-3-RIB_SRC_ADDRESS_ERROR ### Response: (Severity: 3), (Category: IP), (Description: An error occured while trying to retrieve the IP address of the source interface from the RIB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTNLC_FPD-6-EXTEND_TIMEOUT ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-MSI_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected an error), (Recommended Action: Please try to correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-TIME_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: A call to clock_gettime failed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_ASIC_FAULT ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver cannot proceed due to the indicated error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-3-GET_LR_INVENTORY_ERROR ### Response: (Severity: 3), (Category: HA), (Description: Failed to get the lr inventory.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-4-WARN_FIA_DRV_VQI_EPI_MAP ### Response: (Severity: 4), (Category: FABRIC), (Description: Fia VQI to EPI mapping for ALL ports will be restored to default), (Recommended Action: None, this is a warning message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_13_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_13 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-SECURE_BOOT_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: A Secure Boot validation error has been detected on the indicated card. IOFPGA driver will try to recover from this failure by power-cycle the card.), (Recommended Action: If the problem is persitent after multiple retries, it could be hardware related problem with the IOFPGA FPGA.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ALARM_MGR-3-CONSTRUCT_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Error in alarm mgr construction failure.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to delete the number of commit IDs available for rollback operations? ### Response: To delete commit IDs and limit the number available for rollback, use the 'clear configuration commits' command. RP/0/RSP0/CPU0:router#clear configuration commits <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-MCAST_PAGE_ERR_2 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Multicast page error on bridge instance-2.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2SNOOP-3-REG_NETWORK ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the L2SNOOP process try to register itself with the network process and net io process for datapath.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCT_SVR-3-ADDRESS_MOVED ### Response: (Severity: 3), (Category: L2), (Description: After restart of Accounting server the memory occupied by account server configuration is not same.), (Recommended Action: Do a restart of cmn_acct_svr process by using the command ' process restart cmn_acct_svr location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-ROOT_USERDB_LOCK_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: A lock operation on shared resource, called by acctd lwDB failed due to the mentioned error.), (Recommended Action: Collect the output of show logging and inform Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ALPHA_DRIVER-3-OVER_CURRENT_ALARM ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Alpha driver received an over current alarm and the offending slot will remain powered off.), (Recommended Action: This log is to notify that an over current alarm has occurred - please reseat or replace the faulty card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_5_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PMLIB_IM-4-WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: svc pmlib IM encountered an provisioning warning.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect 'show log location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLX_FPD-3-VERSION_MD5SUM_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: PLX FPD EEPROM is corrupted or due to I2C issues, incorrect values are being read leading to mismatch in md5sum between the EEPROM and the stored md5sum. The output of 'show hw-module fpd' will show the affected FPD.), (Recommended Action: In certain cases process restart of plx_fpd on affected or all locations will help to resolve the issue. If that does not help try an upgrade of the FPD.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-3-PTHREAD_OP_FAILED ### Response: (Severity: 3), (Category: OS), (Description: 'Current operation on a pthread failed.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-3-CANNOT_RUN_HBLOSS_SCRIPT ### Response: (Severity: 3), (Category: PLATFORM), (Description: This may be a problem with lack of resources. The heartbeat loss log won't get collected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-BREQ_RCVD_AFTER_POWEROFF ### Response: (Severity: 3), (Category: PLATFORM), (Description: The affected node is booting again after a failure attempt to power it off. The system will try to correct this problem by performing a forced power off operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2VPN_FGID-4-DEBUG_INIT ### Response: (Severity: 4), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB (D)RP component.), (Recommended Action: Platform software will correct itself if this happens.If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-4-QFP_FAILURE_SPI_RX_PHY_RESET ### Response: (Severity: 4), (Category: L2), (Description: Failed enable/disable interrupts on the specified SPI link), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers QFPCPUBridge trace <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers QFPCPUBridge trace <> output, call your Cisco technical support representative and provide the representative with the gathered information. before reloading the line card If this problem persists, reload the line card using hw-module location <>/<>/CPU0 reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FC-6-FWFILE_COPY_INFO ### Response: (Severity: 6), (Category: INSTALL), (Description: Information about the firmware file that is copied by the firmware client), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_THREAD ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an unexpected error performing a pthread operation. The process will restart to attempt to recover. This is possibly due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPFPGA-3-LINE_SIDE_SERDES_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Line-side Rx has errors like aligned/misaligned/burst/overflow ... Fault is detected/cleared.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-NO_MEM ### Response: (Severity: 7), (Category: HA), (Description: Allocating memory failed due to a low-memory condition.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_FPOE_DB_UCORR_ECC_ERROR_LNK0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast FPOE uncorrectable ECC error on link 0), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS DiffServ tunneling modes? ### Response: The MPLS DiffServ tunneling modes define how the MPLS experimental (EXP) field is treated when IP packets enter an MPLS tunnel. The pipe and short-pipe modes preserve the original IP precedence. The uniform mode allows the IP precedence to be overwritten by the MPLS EXP value. It is configured with the tunnel mpls traffic-eng exp command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNVGEN-3-LTRACE_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: Initialisation of trace functionality for nvgen failed. This would affect the debugging of nvgen.), (Recommended Action: If the message recurs, copy and save the message and call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SYNC-7-RWLOCK_ERROR ### Response: (Severity: 7), (Category: OS), (Description: Read-write lock failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-SR_ULOOP_INFO ### Response: (Severity: 6), (Category: ROUTING), (Description: Important information related to microloop avoidance), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EM-7-EEMED_EM_ATTACH ### Response: (Severity: 7), (Category: HA), (Description: The event detector has failed to attach an event handler for synchronous messages.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-EXTRA_AREA_ADDRESSES ### Response: (Severity: 4), (Category: ROUTING), (Description: Area address TLV length TLV_LENGTH contains more than ISIS_MAX_AREA_ADDRESSES from SNPA_STRING (INTERFACE_NAME). This system recieved a hello or LSP containing more than the maximum number of area addresses. The additional addresses have been ignored.), (Recommended Action: Identify the source of the offending packet and correct it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-SPARSE_CORE_DUMP ### Response: (Severity: 6), (Category: OS), (Description: The core for the process is sparse dump), (Recommended Action: Displayed when a process is crashed. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-6-ADJACENCY_DELETE ### Response: (Severity: 6), (Category: L2), (Description: The adjacency for neighbor ip address was deleted.), (Recommended Action: Determine if the forwarding path to the neighbor has gone down.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTY-3-SYSDB ### Response: (Severity: 3), (Category: MGBL), (Description: An unexpected error occurred when the VTY Device DLL interacted with the SysDB client library.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR* *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: 10GE_PLIM-6-XFP_RETRY_READ ### Response: (Severity: 6), (Category: L2), (Description: The Reading of XFP EEPROM failed; Retry is attempted), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-3-MIDPLANE_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB failed to midplane initialization due to the above error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-LOST_EVENT ### Response: (Severity: 4), (Category: L2), (Description: The specified process failed to receive an event that was sent to it.), (Recommended Action: If any problems are seen, they may nbe rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-LINK_LOCK_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: An expected database lock was not held. This could indicate a memory corruption problem.), (Recommended Action: Take a dump of the process and restart it. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-7-LTRACE_INIT ### Response: (Severity: 7), (Category: OS), (Description: Lightweight tracing initialization failed), (Recommended Action: Restarting the processes may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPV6-3-DBREAD ### Response: (Severity: 3), (Category: IP), (Description: Fail to read a DHCPv6 binding database file.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-INIT_PORT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath encountered an initialization error This error could occur for two reasons. 1. The system is low on resources. 2. A hardware error or an error in the DPAA software.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect show log location output, show controllers dpaa trace all location output and show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMS-7-REG_CONTEXT_EXISTS ### Response: (Severity: 7), (Category: SYSDB), (Description: Sysdb is attempting to add a registration that already exists in its registration context. This will cause a sysdb server restart.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-WARN_MAC_IF_SESS_LIMIT_REACHED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions from a particular MAC address on the given access interface has reached the configured maximum.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-3-EVM_CREATE_FAIL ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to create event manager.), (Recommended Action: Restarting the client may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-REPO_ACCESSIBLE ### Response: (Severity: 6), (Category: INFRA), (Description: The IOS-XR install infrastructure has successfully accessed the specified repository following a configuration change.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LSLIB-3-INIT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An initialization error message for an internal software error and will retry to recover the error.), (Recommended Action: No action required - it will keep retry forever to recover from error and once it succesful this error message stops.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_0_PKT_MAXLEN_ERR_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet maximum length error on NPU-0 interface on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_SYSDB_PACK ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-BF_MBE_ERR_FIA00 ### Response: (Severity: 3), (Category: PLATFORM), (Description: FIA00 burst FIFO multi-bit error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-COPY_CURRENT_CMD ### Response: (Severity: 3), (Category: MGBL), (Description: 'Hit general error. The error is displayed in the error message.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE link-management timers feature? ### Response: The MPLS TE link-management timers feature allows the configuration of timers to control the frequency of TE link state advertisements and processing. The periodic-flooding timer controls how often TE LSAs are flooded even without changes. The periodic-flooding threshold controls by how much bandwidth must change to trigger immediate flooding. The degraded-interval timer controls how often TE metrics are recalculated on degraded links. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_NETIO-5-SUBBLOCK_VERSION ### Response: (Severity: 5), (Category: L2), (Description: When the PPP NetIO DLL was upgraded the existing data version was incompatible with the new software. NetIO will be restarted to recover the appropriate state.), (Recommended Action: This is not a problem, the message is just to explain why NetIO has restarted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-VIRT_INST_MGMT_INTERFACE ### Response: (Severity: 3), (Category: OS), (Description: A management interface is configured but none is defined.), (Recommended Action: Deactivate the virtual service, remove the management interface configuration CLI, and reactivate the virtual-service.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-4-STBY_NOT_SUPPORTED ### Response: (Severity: 4), (Category: ROUTING), (Description: Clear command is not supported on standby RP), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-7-TFTP_DEBUG_REG_FAIL ### Response: (Severity: 7), (Category: IP), (Description: Failed to register debugging services for tftp server. The system will continue to funtion, as this is not ststem impacting issue.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-3-ERROR_MSG ### Response: (Severity: 3), (Category: L2), (Description: This is a debug message in the PSE Driver to indicate an operation or condition.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-ASIC_FAULTS ### Response: (Severity: 3), (Category: FABRIC), (Description: The asic fault detected and the details of the fault will be displayed in the string.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-EXCEED_MAX_PFX_LIMIT ### Response: (Severity: 4), (Category: ROUTING), (Description: User has configured a maximum-prefix limit which is lower than the current prefix count. In order to reduce the current count below the configured value, user needs to reset the session to reduce the prefix count if neighbor does not support route-refresh.), (Recommended Action: Reset the neighbor session if neighbor does not support route-refresh) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COMMS-3-SAVE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The client failed to save data to Checkpoint. If the process restarts before the save can be retried, then data loss could occur.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-TMCAT_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a parity error.), (Recommended Action: Please correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-EDM_INIT_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to initialize EDM.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-3-DLSYM_FAIL ### Response: (Severity: 3), (Category: MGBL), (Description: This message indicates that a process could not find the specified symbol in DLL name. The name of this DLL is included in the message. Functionalites of the process that failed to get the symbol from this DLL will be impacted.), (Recommended Action: This indicates the problem with DLL.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-XIF_VQI_TBL_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected XIF VQI table multi-bit error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_HB_MISS ### Response: (Severity: 3), (Category: OS), (Description: The bcdl client library detected that it should have received a heartbeat from the agent, but didn't), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-MAIN_INIT ### Response: (Severity: 3), (Category: OS), (Description: Shmwin server initialization failed when setting up some resource in shmwin server main.), (Recommended Action: *SUPPORT) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-SYSDB_UNBIND_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The show line command was unable to un-bind to SysDB), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-4-PULSE_HNDLR ### Response: (Severity: 4), (Category: ROUTING), (Description: FIB internally manages its activity using 'pulses'. An error occurred while processing pulses. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-TARGET_CFG_UNLOCKERR ### Response: (Severity: 3), (Category: MGBL), (Description: Nvgen client failed to release exclusive lock held by this session.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different IS-IS authentication types? ### Response: The IS-IS authentication types are: - Clear-text password (per-interface or per-area) - HMAC-MD5 authentication with key chain (per-interface or per-area) - Hashed password in LSPs (validate or send-only) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_IR0_INTR_DC3_MAX_DROP_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_IR0_INTR_DC3_MAX_DROP_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDPSNMP-3-SYSDB_BIND ### Response: (Severity: 3), (Category: SNMP), (Description: udp_snmpd binds to SysDB to receive notifications on the trap destinations udp_snmpd typically use these notifications to add trap destination to the trap Q. If udp_snmpd cannot bind to SysDB, these SysDB notifications will not be received, and thus some trap desination will not be added and traps will not be sent to those destinations.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MIB-3-BADTRANSPORT ### Response: (Severity: 3), (Category: SNMP), (Description: Attempted to perform the indicated operation on an unknown transport type. This is an internal software error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRP-3-SW_INIT ### Response: (Severity: 3), (Category: L2), (Description: Some requested operation failed during initialization. The text of the message displays the failed operation with error code.), (Recommended Action: This error is seen while SRP is getting initialised on LC. Check 'sh log',if any other error is seen on linecard or MSC. Try performing SPA/PLIM process restart by executing CLI 'process restart location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_QOSEA-6-AGG_BUN_INCONSISTENCY_CLEARD ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_1_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-3-MALLOCFAIL ### Response: (Severity: 3), (Category: MGBL), (Description: The requested memory allocation is not available from the specified memory pool. The current system configuration, network environment, or possibly a software error might have exhausted or fragmented the router's memory.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_HT0_OFLOW ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an HTDP overflow error on the HT0 interface. This error is logged when a packet is received and has no buffer available to receive it.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZEN-6-FPD_ERR ### Response: (Severity: 6), (Category: INFRA), (Description: The message indicates that new zen boot header is missing, have to use backdoor command to do upgrade. The command will upgrade spi flash with new boot header, working image, and golden image.), (Recommended Action: Go to /opt/cisco/calvados/bin, try ./zen_driver_test_cli -A -c 0.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TAMSVCS-3-NOT_INITIALIZED ### Response: (Severity: 3), (Category: SECURITY), (Description: tamsvcs process failed to initialize succesfully.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAOC768-3-PIO_CRITICAL_ERROR ### Response: (Severity: 3), (Category: L2), (Description: A critical error occurred in PLAOC768 Driver which involves exiting the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_REDDRV-3-NODE_NOT_RELOADED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Shelfmgr running on the active RP has to reload the node but its fails here.), (Recommended Action: DRP is self rebooting due to shelfmgr reload fails, so it's rebooting ungracefully with kernel dump.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-EA_ICL_CREATE_FAILURE ### Response: (Severity: 3), (Category: QOS), (Description: QoS EA encountered an error when an ICL interface was being created. No hardware programming was done for the ICL interface. The error may be becasue there was a QoS Policy already applied on the interface.), (Recommended Action: Try removing the QoS policy and ICL related configuration, and then try creating the ICL without any QoS policy attached on the interface. In terminal configuration mode 'interface ' 'no service-policy input | output' 'commit') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_QOSEA-3-FAILURE_DURING_MODIFY ### Response: (Severity: 3), (Category: QOS), (Description: QoS EA encountered an error when modifying the policy on an interface. Neither the old policy nor the new policy is applied in hardware for this interface.), (Recommended Action: Try removing the QoS policy on the interface for which this error message is printed from configuration, and then reattach the policy to the interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-INTERFACE_RESYNC_QUERY_ERROR ### Response: (Severity: 4), (Category: INFRA), (Description: The linux kernel has requested a resync of information, and so XLNCd has marked information about the interface as stale and queried linux kernel for a replay of that information. However this query has errored, meaning XR and linux may now be out of sync in terms of interface attributes), (Recommended Action: If the problem persists, restart XLNCd. If the problem persists through process restarts, If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-3-ERR_BIST ### Response: (Severity: 3), (Category: FABRIC), (Description: Built-In Self-Test failed for Fabricq ASIC.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPMC_GTRIE_DEFAULT-4-INIT_WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: Error while initializing Gtrie. Initialization will continue), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-7-SHELFMGR_PULSE_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: The IPC message from i2c server to shelfmgr failed due to the reason listed in the msg.), (Recommended Action: Check the path of file specified for download) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIRTIO-4-CTX_SHORTAGE ### Response: (Severity: 4), (Category: L2), (Description: Set: A global SPP context shortage was detected in the VirtIO plug-in. Reception of packets from ports and other nodes is likely to stop at any point. Clear: A previous SPP context shortage was cleared. Normal packet I/O operations will resume.), (Recommended Action: If the problem does not clear, the node should be reloaded.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-2-FAILED_TO_FIND_VRF_DEFAULT_NNS ### Response: (Severity: 2), (Category: INFRA), (Description: XLNCd requires vrf-default to exist as a Linux NNS for the process to run. The namespace should be created at startup, and if it does not exist, the system will be in a bad state.), (Recommended Action: Reload the box: the system has got into a bad state and should be started again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-GROUP_AUTHOR_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: Group authorization failed.), (Recommended Action: 'Check AAA connectivity') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TIMER-3-TWCHUNKFREE ### Response: (Severity: 3), (Category: OS), (Description: Resources were not able to be deallocated in timer wheels.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPD-4-RATE_LIMIT_EXCEEDED ### Response: (Severity: 4), (Category: IP), (Description: The error occurs when DHCP control packet rate exceeds the configured limit or the default vaules 500 CPS.), (Recommended Action: Control the DHCP rate using) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_2_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-4-RX_UNSUPP_SESSION_PARAM ### Response: (Severity: 4), (Category: ROUTING), (Description: The session parameters proposed by an LDP peer differ from those preferred by the platform. The differences are not sufficient to prevent the LDP session from being established, but may have an impact on label distribution operation.), (Recommended Action: If the parameters identified relate to the optional path vector-based loop detection mechanism, note that the IETF LDP specification recommends that when Loop Detection is enabled in a portion of a network, it is recommended that all LSRs in that portion of the network be configured with Loop Detection enabled and with the same path vector limit. If the parameters identified relate to some other aspect of the LDP session and the message occurs repeatedly, copy it exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB-7-ERR_EVENT_CONN_OPEN ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to open connection with event manager. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_HFR-5-SYSDB_INIT ### Response: (Severity: 5), (Category: ROUTING), (Description: The MFWD-HFR library encountered internal error during Sysdb init setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-1-LOSS_OF_SYNC ### Response: (Severity: 1), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered Loss of sync on interlaken interface.), (Recommended Action: This fault would result in traffic loss. Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-RTRINIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during initialization of the router thread.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the additional following commands: - show tech-support routing ospfv3 detail) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-MEM_ERR ### Response: (Severity: 3), (Category: L2), (Description: fail to allocate memory.), (Recommended Action: show process memory <> to find out whehter there is potential memory leak show memory <> to confirm system memory goes low *SH_CMD sh plim pla trace info <> *SH_CMD sh plim pla trace error <> *SH_CMD sh plim pla trace all loc <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_GROUP_CREATE_LWG ### Response: (Severity: 3), (Category: OS), (Description: A call to a group services interface failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: G8032-4-FOP_PM_LOWER_LEVEL ### Response: (Severity: 4), (Category: L2), (Description: A ring node detects an R-APS message with a lower level than the configured G.8032 instance level for that APS Channel. This is a Failure of Protocol - Provisioning Mismatch - Level due to a misconfiguration of the APS level of nodes in the ring.), (Recommended Action: Identify the other node with Node Id and reconfigure it with a matching APS level.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IPV4_MRIB-3-INIT_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: MRIB (multicast routing information base) failed to initialize. MRIB is the central routing information base for multicast components. It provides coordination among all multicast routing components and forwarding. The effect is that multicast forwarding will not function. %s - indicates the reason for the failure.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process when this error is encountered to recover. Execute 'show process mrib' to verify that the process is up and running. If it is still non-operational, try doing 'process restart mrib' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WDMON-3-PM_TOO_MANY_RESTARTS ### Response: (Severity: 3), (Category: INFRA), (Description: Sysadmin process manager has restarted too frequently. Sysadmin will reboot if the system is unable to correct this condition on its own.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_CLI-7-STRING_LENGTH_TOO_LONG ### Response: (Severity: 7), (Category: OS), (Description: The string length is too long.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-3-LINK_ERR_EGR_TX_FIFO_OVERFLOW ### Response: (Severity: 3), (Category: PLATFORM), (Description: Link up failure due to egress path failures.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - show tech-support ethernet interface location <> - show controller <> phy - show controller <> internal) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRG-4-SYNC_ERROR ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The requested sync of subscriber sessions could not be done due to specified error. Operation can be retried after error condition is resolved. This is in response to the synchronize CLI exec command.), (Recommended Action: None required since this is in response to an administrative action that caused this synchronization of sessions. Operation can be retried and troubleshooting required if error persists.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-NO_PREQ_ENTRY ### Response: (Severity: 7), (Category: OS), (Description: Couldnt find pending request entry in the pending list. The response which came couldn't find the corresponding pending request in the list.), (Recommended Action: This is a Debug message.No action required. If the problem persists,Contact Support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnetmgmt-4-DSCP_VERIFY ### Response: (Severity: 4), (Category: IP), (Description: An error occurred while trying to verify dscp configuration. This failure can occur due to any of the following reasons. 1. when Item name not specified. (item name will be like //dscp) 2. If the size of the buffer used to store the Item name is less than the required 3. Fail to open the file pointed by the Item name.), (Recommended Action: Please get the information specified under the component required_info and call your Cisco technical support representative and provide the gathered information with this error message text. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_SYSLOG_PRX-4-WARNING_FIPS ### Response: (Severity: 4), (Category: SECURITY), (Description: The sshd encountered a warning condition.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-4-DB_INIT_FAILURE ### Response: (Severity: 4), (Category: MGBL), (Description: An error was encountered during initialization of the commit database. This is most likely due to an error in reading the commitdb info file, which could be due to disk0: or CFS being corrupted or the file itself being truncated. The system recovers from this situation by cleaning up all files in commitdb if needed and initializing it empty. This may result in loss of all rollback points. However, this should not cause loss of configuration as the system applies the alternate ASCII file maintained for such situations. In certain scenarios, changes made in the last one or two commits may be lost.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WATCHDOG-3-FAIL_TO_INIT ### Response: (Severity: 3), (Category: INFRA), (Description: An unrecoverable error occurred during watchdog monitoring service initialization. Card will reload if the system is unable to correct this condition on its own.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is Management Plane Protection (MPP) and why is it used? ### Response: Management Plane Protection (MPP) is a feature that helps secure management traffic by explicitly designating the interfaces that management protocols can use. It restricts the interfaces on which management protocols are allowed, preventing unauthorized access if an attacker gains control of a non-management interface. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_PMLIB-2-ERROR_INIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Platform Manager client library encountered an initialization error A reason text will be supplied to describe the error.), (Recommended Action: Check if the process is blocked using- 'show process blocked location ' if the pm process is blocked restart the process using- 'process restart location ' to recover from this error. Please collect output for 'show log location ' and 'show memory summary location ' from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_AGG-3-PROCAGENT_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB aggregator failed procagent initialzation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAN-3-BUSY_FLAG ### Response: (Severity: 3), (Category: PLATFORM), (Description: The busy flag for this particular operation mentioned in the message failed to clear for some reason. The MLAN switch was reset. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Collect console log and the following information. - show control mlan switch-status - show control mlan switch-atu - show control mlan port-status 1 - show control mlan port-counters 1 - show control mlan port-status 2 - show control mlan port-counters 2 - show control mlan port-status 3 - show control mlan port-counters 3 - sh process ether_ctrl_mgmt) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WAN_LIB_IFDB-3-UNKNOWN_IDBTYPE ### Response: (Severity: 3), (Category: L2), (Description: If IDB type will not be find out in subtree recursively i.e.it will iterate on each non-leaf child untill all leaves in subtree have been visited. If this IDB type does not recognised that means it is not a leaf , not a root and not a node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-1-ERR_HW_DISABLE_NODE ### Response: (Severity: 1), (Category: L2), (Description: A hardware error is detected on the PLIM. Software will take action as described in the error message to try to recover from the error. The hardware error and the software recovery action will put linecard in RESET state. Device: %s%s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Software action: %s - the action that software will take to try to recover from the error.), (Recommended Action: If the message recurs, diagnostics should be executed on the PLIM and MSC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LWMESS-7-LOCK_CONN ### Response: (Severity: 7), (Category: OS), (Description: The mutex for the channel connection list could not be held), (Recommended Action: This is an internal error and should be reported to TAC. Try re-starting the offending application. If that does not work, a memory dump should be taken (to assist TAC) and the router should be rebooted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rlogin-3-WAIT ### Response: (Severity: 3), (Category: IP), (Description: rlogin client's call to wait() system call failed), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-4-MAP_SERVER_SITE_EID_PREFIX_LIMIT_THRESHOLD ### Response: (Severity: 4), (Category: IP), (Description: 'Dynamic EID prefix entry count has reached or exceeded ' 'the configured threshold. This is used to warn the ' 'adminstrator that corrective action may need to be ' 'taken to avoid reaching the map-server EID prefix ' 'limit.'), (Recommended Action: 'No immediate action is required unless the ' 'entry count is very close to the configured ' 'limit at which point the limit on the map-server ' 'needs to be adjusted.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-LSA_LEN ### Response: (Severity: 3), (Category: ROUTING), (Description: The router router-LSA became larger than the OSPF protocol imposed maximum. Only partial link information (up to allowed maximum size) is inserted into the LSA.), (Recommended Action: You need to decrease the number of OSPF interfaces in the reported area. Alternatively, making the interfaces unnumbered will also decrease the router-LSA size.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEAT_MGR-4-TCAM_ERR ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Feature Manager encountered error in completing TCAM operation. This can lead to mismatch between hardware and software configuration.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you verify the software installation on Cisco IOS XR? ### Response: To verify software installation on Cisco IOS XR, the 'show install active' command can be used to display the currently active software packages on the router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of using the 'install add' command in Cisco IOS XR? ### Response: The 'install add' command in Cisco IOS XR is used to add new software packages to the router without disrupting the current operation, allowing for seamless updates and upgrades. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the TURBOBOOT process in IOS XR? ### Response: TURBOBOOT is a process used for the initial installation of IOS XR software images and packages onto the router's boot device (usually disk0: or disk1:). It loads the image from a .vm file, validates it, creates required directories, and copies the packages to the boot device. TURBOBOOT is typically invoked from the router's ROMMON mode. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEAT_MGR-3-REPRGM_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: When an ACL definition is changed which is used by a some class-map as a match criteria, it result in reprogramming of all the polices which are using this class-map and are already applied to some interfaces. This message lists the policy-map and ACL for which errors have occured during reprogramming.), (Recommended Action: Detach policy-map in the error message from all interfaces of the line card where issue is seen. Now, re-attach policy-map to the interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_0_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MMAP_PEER-3-READLINK ### Response: (Severity: 3), (Category: OS), (Description: Failed to get original filedname for the fd.), (Recommended Action: Copy the message exactly as it appears, and report it your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAMSG-3-NULL_EVM ### Response: (Severity: 3), (Category: L2), (Description: Only critical if SPA debugging is not yet initialized. It means somebody may try to use uninitialized debug events.), (Recommended Action: Try to use initialized debug events) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEM_PLATFORMS-2-ERR_STR ### Response: (Severity: 2), (Category: L2), (Description: Error in cem operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_CONF_PRX-4-WARN_ERRNO ### Response: (Severity: 4), (Category: SECURITY), (Description: Warning.), (Recommended Action: 'NO ACTION') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_HFR-3-ERR_CCI_CREATE_Q ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cannot create pdma queue required. Likely a asic driver does not come up properly %d - 0 ingressq; 1 egressq; 2 fabricq 0; 3 fabricq 1 %d - number of seconds elapsed), (Recommended Action: Investigate if driver processes(ingressq, egressq or fabricq) initialized properly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_PKT_WITH_INVALID_SID_RECEIVD ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: A packet with an invalid session ID has been received. This indicates that a subscriber has started communicating with this AC after initiating this session with another AC.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_OUT_MEM_UCORR_ECC_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast output memory uncorrectable ECC error on link 2), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_FILE_PATH ### Response: (Severity: 3), (Category: SECURITY), (Description: Error description, file path.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_7_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-OBFL_FLASH_ACCESS_FAILED ### Response: (Severity: 4), (Category: MEDIASVR), (Description: This ios_msg is raised upon OBFL flash access failed.), (Recommended Action: Contact TAC to collect /var/log/kern.log from host to get UBIFS error message from kernel log) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTY-2-PANIC ### Response: (Severity: 2), (Category: MGBL), (Description: A critical internal error has ocurred which requires the process to restart. For example if a lock cannot be released then the process is restarted to avoid deadlock.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPP_PKT_F3_MBE ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPP packet FIFO 3 multiple bits error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ALARM_MGR-3-LVM_CREATE_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: LVM create failure.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an SNMP community? ### Response: To configure an SNMP community, use the 'snmp-server community' command in global configuration mode. RP/0/RP0/CPU0:router(config)#snmp-server community public ro <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-5-LISP_TCP_SESSION_STATE_CHANGE ### Response: (Severity: 5), (Category: IP), (Description: 'This message is a notification that the specified LISP TCP session ' 'has come up/down. Please note that the messages are rate limited to ' '1 message per second and a session state could have changed without ' 'generating a message'), (Recommended Action: 'If the session is expected to come up/down then no action is required. ' 'Otherwise, investigation regarding the session going up/down should ' 'be done.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-EVENT_ASYNC_ATTACH_FAIL_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-EXTRACT_IDPROM_INFO ### Response: (Severity: 3), (Category: DRIVER), (Description: Card manager was not able to extract inventory info from the IDPROM data of the module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_AGT-3-ISSU_DIR_COMM_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: ISSU Agent is unable to send a message to ISSU Director via ISSU Director's CAPI service. This suggests that there is an issue with ISSU Agent's connection with that service. ISSU Agent will respawn to retry.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_AUTH ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error encountered in RIP authentication module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-2-RSI_UNKNOWN_EVENT ### Response: (Severity: 2), (Category: OS), (Description: RSI sent unknown event), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ_MGR-7-INFO_IMDR ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabricq server iMDR debug/info messages. These are Unit-Test log messages and presently they are commented. So, only Dev team can enabled this message and use it. Hence more info on this log is unncessary.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGV6_SERVICES-2-ERR_CGV6_SERVICES_INIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: An error occurred in initialization of CGV6 Services . If this occurred during process startup or RP Switchover, then the process may be restarted.), (Recommended Action: Restart the cgv6_services process (process restart cgv6_services location <>) If the issue persists, do a cold reboot Services CGV6 MSC.If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_VRFNRES ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRLLIB-3-DETECTED_ERROR_PDMA ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cpuctrl driver detected an error during packet DMA.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-6-CARD_OIRIN ### Response: (Severity: 6), (Category: PLATFORM), (Description: Entity specified in the messages is inserted into the chassis and inventory manager is updated. This message is used by CWI/CTM to determine when the entity-related information (read from the EEPROM) is available in inventory database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_COMM-3-CARD_SUPPORT_ERROR ### Response: (Severity: 3), (Category: L2), (Description: This is a message indicating unknown nodeid or card type and the process will abort), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-ASIC_HALTED_VIA_CPLD ### Response: (Severity: 6), (Category: FABRIC), (Description: The specified device is halted using the CPLD register.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-INIT_LTRACE_ERROR ### Response: (Severity: 4), (Category: MEDIA), (Description: Media server is unable to initialize the ltrace buffer for logging.), (Recommended Action: Collect system log information. No functional impact if it is just the ltrace buffer initialization issue. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS VPN carrier supporting carrier feature? ### Response: The MPLS VPN carrier supporting carrier (CSC) feature enables one MPLS VPN service provider to allow other service providers to use a segment of its backbone network. The service provider that provides the segment of the backbone network to the other provider is called the backbone carrier. The service provider that uses the segment of the backbone network is called the customer carrier. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the protocol shutdown command in IS-IS? ### Response: The protocol shutdown command is used to administratively shut down IS-IS on a router. When IS-IS is shut down, the router does not send or receive IS-IS packets and all IS-IS adjacencies are torn down. This command is useful for gracefully shutting down IS-IS during maintenance or troubleshooting. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP-4-ISSU_BRINGUP_DELAY ### Response: (Severity: 4), (Category: L2), (Description: Set: Bringup Delay is active for one or more ports. The port states may change when ISSU Run is activated, resulting in a change in the active topology. Clear: The alarm is cleared for one of the following reasons: - Bringup Delay is no longer active on any ports, and the active topology may have changed as a result. - The ISSU operation has been aborted, and Bringup Delay is still active for one or more ports. The active topology is unchanged.), (Recommended Action: Use the output of show spanning-tree mst to verify which ports have Bringup Delay active, and to check the expiry time of the timers. To avoid a change to the active topology, ensure that Bringup Delay is not active on any ports when activating ISSU Run.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rspp_drop-3-DEBUG ### Response: (Severity: 3), (Category: SERVICES), (Description: A problem with the debug infrastructure was encountered by the service diversion drop processing in NetIO. This is not fatal, and simply means that the 'debug services diversion drop' commands may be unavailable. All non-verbose messages are still traced in a circular buffer, and the most recent of these can be inspected with the 'show services diversion drop trace' commands.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COND_DEB_RP-3-NOIPCONDDBG ### Response: (Severity: 3), (Category: SECURITY), (Description: The request to use using IP address as condition for a crypto debug message could not be accomplish.), (Recommended Action: If displaying of crypto debug messages is needed, please use regular crypto debug mechanism instead of conditional crypto debug mechanism.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EM-7-FMS_LWM_CONNECT ### Response: (Severity: 7), (Category: HA), (Description: The msg_chan_connect function reported an error trying to connect to the specified Embedded Event Manager server channel.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-4-CFG_FAILED ### Response: (Severity: 4), (Category: HA), (Description: wd_config_init failed due to sysdb intialization problem.), (Recommended Action: Collect all logs, especially those from wdsysmon. Also collect output from 'show watchdog trace'. Forward the messages to technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-OPERATION_COMPLETED_WITH_ERRORS ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified install operation in the error message completed with errors. The operation will be a single command upgrade (install replace commit)), (Recommended Action: The reason for this install operation failure has to be analyzed. Check the install operation log by 'show install log ' id is same as displayed in the syslog message which will be helpful to understand the reason for the install operation failure. Collect the show tech logs by running 'show tech-support install' and forward the logs to the TAC. Collect the install operation logs by running 'show tech-support install' on admin as well. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_QOSEA-6-AGG_BUN_INCONSISTENCY ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCMD_LIB-5-FRR_BELOW_THRESHOLD ### Response: (Severity: 5), (Category: ROUTING), (Description: Threshold configured for RCMD Frr Coverage monitoring was reached.), (Recommended Action: If the time taken is unusually low Frr coverage then further analysis can be performed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_DRIVER-7-NODEID_FAILURE ### Response: (Severity: 7), (Category: OS), (Description: An error happened for a nodeid operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-5-TABLE_PER_PREFIX ### Response: (Severity: 5), (Category: ROUTING), (Description: Error while enabling/disabling per route accounting in a table), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-DEVICE_INIT_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Unable to initialize device.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-XR_ACTIVE_PKGS_MISSING_IN_REPO2 ### Response: (Severity: 3), (Category: INFRA), (Description: One or more active XR packages are not found in repository. When a node goes through internal pxe or a new card is inserted, XR will fail to come up on that node as packages in active software profile is missing and XR prepare will fail.), (Recommended Action: Install add the packages that are mentioned to be not found in the XR repository and please reload all the node(s) on which XR failed to come up, reload the node after install add is successful.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-4-FIXED_INTERVAL_TEST ### Response: (Severity: 4), (Category: DIAG), (Description: The specified health monitoring test interval is not user-configurable and therefore cannot be changed.), (Recommended Action: Nothing. The specific health monitoring interval is not user-configurable by design so nothing can be done to change the interval.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PVSTAG-4-UNEXPECTED_BPDU_RECEIVED ### Response: (Severity: 4), (Category: L2), (Description: A BPDU was received on a port that was configured for Portfast. This port will now revert to a 'non-edge' port.), (Recommended Action: Check network configuration. Should this port really be configured for portfast? Has a new network device been added to the network?) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_SB_SERDES_1_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data south bound serdes link 1 failure on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISKCAM-3-ERR_PASS_THROUGH ### Response: (Severity: 3), (Category: PLATFORM), (Description: Media device shutdown operation failed to pass through.), (Recommended Action: *SH_CMD show logging*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND-3-ERR_EXTERNAL_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The IPv6 Neighbor Discovery (ND) process (ipv6_nd) is unable to set up tracing. This will not prevent ND from working, but will impair its ability to record its activities and will make diagnosing any unexpected behaviour more difficult. This condition may result from a lack of system resources such as memory.), (Recommended Action: Use the show memory summary [location ] command to determine the state of system memory. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-5-MEM_UNTHROTTLE ### Response: (Severity: 5), (Category: IP), (Description: At some point, memory usage had exceeded ANCP's budgeted threshold. Memory has been freed putting it back in a safe level of memory usage.), (Recommended Action: No action needed since memory is back in the safe zone.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-4-GX_DISABLE ### Response: (Severity: 4), (Category: SECURITY), (Description: Disabling diameter gx app is not recommended.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_DISC-3-DU_SYSDB_HW_TREE_BIND_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Binding of sysdb to hw tree gets failed. Also publishing information to sysdb and setting up sysdb name for platform in hw tree got failed.), (Recommended Action: Copy the System Message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-5-PLIM_EVENT_INIT_ERR ### Response: (Severity: 5), (Category: L2), (Description: Creating SPA event handling server failed.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-4-RFI ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message provides information about the fault occurred on the interface.), (Recommended Action: The message is just for information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-4-WANPHY_SPA_TIMEOUT ### Response: (Severity: 4), (Category: L2), (Description: If the Wanphy spa exist in ISSU case then 3 mins timeout is used), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-PROC_SHUTDOWN_JID ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-CFG_INVALID ### Response: (Severity: 4), (Category: L2), (Description: There was an error when decoding the config from SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REPLICATOR-7-NO_CB ### Response: (Severity: 7), (Category: LIBRARY), (Description: The replicator library did not receive a callback from the transport library. The update will be allowed to continue without the replication acknowledgement. If any replicas have not received the update, they will resync on the next update.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-3-SESSION_NOTIFICATION_ABORT ### Response: (Severity: 3), (Category: MGBL), (Description: Failed to notify line status change.), (Recommended Action: If you want to close existing session, please run 'clear line' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRG-5-ROLE_SLAVE ### Response: (Severity: 5), (Category: SUBSCRIBER), (Description: The SRG role from the concerned group has change to SLAVE from either MASTER or uninitialized role. This is a normal redundancy event.), (Recommended Action: None required if there has been any network event or administrative action that caused this redundancy role change. Subscriber status may be checked on the master and slave routers to verify consistency, if desired.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-OUT_OF_MEMORY_UNKNOWN_SIZE ### Response: (Severity: 3), (Category: L2), (Description: The system is low on memory.), (Recommended Action: This indicates a low-memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_CHOC_DSX-1-SPA_RESET_NEEDED ### Response: (Severity: 1), (Category: L2), (Description: Due to framing change on SONET port, SPA need to be reloaded for spa to function properly.), (Recommended Action: Reload the SPA using CLI 'hw module subslot reload') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an L2VPN bridge domain ARP suppression? ### Response: To configure ARP suppression for an L2VPN bridge domain, use the 'arp suppression' command within the bridge-domain configuration. l2vpn bridge-domain BD1 arp suppression <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-FGID_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-MEM_ALLOC_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: OSPFv3 was unable to allocate memory for the specified resource.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. If conditions warrant, upgrade to a larger memory configuration. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPP-3-ERR_MALLOC ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error. System is out of memory - malloc failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-3-NETLINK_MSG_PUT_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: libnl failed to allocate a message header for querying the interfaces in a network namespace.), (Recommended Action: If the system is experiencing memory exhaustion, resolve the underlying issue then restart the process. If the problem persists, Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-5-MPLS_REPLAY_OK ### Response: (Severity: 5), (Category: ROUTING), (Description: Serivce layer successfully replayed MPLS objects to Label Switching Database from a previosly errored state), (Recommended Action: No action needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-7-NODEID_INFO ### Response: (Severity: 7), (Category: OS), (Description: Could not get the nodeid corresponding to the node name %d- error code %s- node name), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_RX_ALIGN_LOSS_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Rx alignment loss on XAUI to NPU-1 interface on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_RIB_CONN_SETRETRY ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to set the linear retry period for connecting to the RIB. This error will not affect IS-IS operation but does indicate an unexpected result.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4MC_STATIC-7-ERR_EVM_CREATE ### Response: (Severity: 7), (Category: ROUTING), (Description: Internal error. Failed while creating event manager), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELOGM-4-DEBUG_CLEANUP_FAILED ### Response: (Severity: 4), (Category: L2), (Description: Whilst exiting, the Global Manager failed to cleanup the debug module. The process will exit anyway, and no further errors should be seen.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure a prefix list? ### Response: To configure a prefix list for route filtering, use the 'prefix-set' command in global configuration mode. RP/0/RP0/CPU0:router(config)#prefix-set PREFIX_SET1 RP/0/RP0/CPU0:router(config-prefix-set)#10.1.0.0/16 le 24 RP/0/RP0/CPU0:router(config-prefix-set)#exit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-HELLOINIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during initialization of the hello thread.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the additional following commands: - show tech-support routing ospfv3 detail) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-5-SERVICE_LEARNT ### Response: (Severity: 5), (Category: SERVICES), (Description: 'The device received a new autonomic service ' 'by Service Discovery Protocol'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-7-ERR_INTERNAL ### Response: (Severity: 7), (Category: ROUTING), (Description: An internal system error occurred.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GIRO-6-ERROR_CHKPT_SAVE ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: A failure was encountered in recording the latest data persistently. The operation will be retried the next time interface parameters change. However, a process restart in the meantime (e.g. due to an install operation) may cause incorrect parameters to be programmed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVENT-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: ROUTING), (Description: Allocation of the specified resource failed because of a low memory condition.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-IP_ADDR2_HEX_STRING_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: 'Conversion of ip_addr_t to string failed'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-POWERDOWN_RESET ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node will be reset because user has administratively 'power disable' or 'no power disable' the node.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-ABORT ### Response: (Severity: 6), (Category: PLATFORM), (Description: An unexpected software event has caused the shelfmgr process to restart.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO-3-ERR_QAD_EGRESS_QUEUE_MISSING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to find the qad queue for egress packets. This could causes applications using this qad queue not sending out packet %s - QAD queue name %s - thread name), (Recommended Action: Reload the card. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-MAC_1_RX_FRAME_ERR_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: MAC on NPU-1 received an errored frame interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_EDM-3-SYSDB_BIND_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The process failed to connect to SysDB while starting the indicated subsystem.), (Recommended Action: restart policy_repository and check for re-occurence of issue) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-GEN_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: General error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONCERTO-7-ERR_EVM_CREATE ### Response: (Severity: 7), (Category: PLATFORM), (Description: CONCERTO Event Manager create error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-7-ERR_EVM_CREATE ### Response: (Severity: 7), (Category: PLATFORM), (Description: ClkCtrl Event Manager create error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-MEMORY_INFO_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: Config process failed to get memory state info from wdsysmon when it came up.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-7-FILE_OPEN_FAIL ### Response: (Severity: 7), (Category: INSTALL), (Description: Failed to open the specified file.), (Recommended Action: Check for disk corruption using 'fsck' disk check CLI. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_AMCC2035-3-OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-ASSERT_RL ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal consistency check failed. There may be no immediate impact on traffic, but this issue should be addressed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6-4-PA_BIND ### Response: (Severity: 4), (Category: IP), (Description: A call made to pa_client_bind has failed.), (Recommended Action: Restarting lpts_pa and then ipv6_io may fix this issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-ASIC_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: The asic initialization failed due to the above mentioned error.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VASI_MA-3-INTF_CREATE_FAIL_CLEANUP ### Response: (Severity: 3), (Category: SERVICES), (Description: The VASI Manager failed to completely clean up interface state after an interface creation failure. This would have left the system in an inconsistent state. This will mostly occur due to invalid arguments.), (Recommended Action: Check the debug traces for errors to know the exact reason for failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TEMP_OUT_OF_RANGE ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-LABEL_ERR_MOD ### Response: (Severity: 3), (Category: ROUTING), (Description: Route already has a local-label from another protocol.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBIMGR-3-NULL_PTR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An internal error has occurred in an application that has caused it to pass invalid data to the MBI infrastructure. The current request or operation may not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-EDM_INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: Failed to initialize the EDM, for CE-TFTP server. The system will not be impacted and will come up. *RECUR*), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REBOOT_LIB-3-INVMGR_CONN_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: Failed to connect to inventory manager.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX8111-2-UNSUPPORTED_REQUEST ### Response: (Severity: 2), (Category: PLATFORM), (Description: PCIE device reported an unsupported request), (Recommended Action: This error is a momentary error and software should be able to correct it. If this error persisted for a period of 60 seconds, please perform the following actions: 1. Please check for read/write access to the attached compact flash or eUSB device by creation a temporary file. 2. If the problem still exists, please reload the board using the following command: 'reload location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can BGP prefixes be originated using the network statement? ### Response: The network statement is used to advertise a prefix if it exists in the routing table. The mask of the network statement must match the mask in the routing table. The route must be in the routing table before BGP will originate it. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-2-GEN_CRIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Error in CPU Control FPGA operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_TCAM_RM-3-LOG_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: An error occurred in CPP TCAM RM which involves exiting the process.), (Recommended Action: *SH_CMD show controllers pse qfp infrastructure tcam resource-manager usage location < > * *SH_CMD show controllers pse qfp infrastructure tcam resource-manager error parity location < > * If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VI_REPL-3-ISSU ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A failure occurred during the special handling that takes place during an ISSU operation.), (Recommended Action: The consequences of this error are unpredictable. There may be no problem but it is also possible it will affect virtual interface configuration during the ISSU. It is advisable to check all virtual interface configuration on the active and standby nodes before continuing with the ISSU operation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-7-ERR_REGISTER_SET ### Response: (Severity: 7), (Category: FABRIC), (Description: An attempt to write a Hardware register failed.), (Recommended Action: Run diags on the board and contact TAC support. If it is possible to isolate the trigger point for the set failure, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-THREAD_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: OSPFv3 failed to create a thread essential to its operation. This is an internal error. An automatic restart of the OSPFv3 process was necessary to attempt recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-3-CONNECT_ATTACH ### Response: (Severity: 3), (Category: OS), (Description: SSM process tried to connect to the clients channel using ConnectAttach api and encountered a failure.), (Recommended Action: Collect system log information for the reported service and pid. Collect show process , follow process , show process blocked Collect show tech ssm. If this message is seen repeatedly, capture the output of debug event-manager all job . 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_ERRDIS_NOTSUPPORTED ### Response: (Severity: 4), (Category: L2), (Description: A member interface could not be error-disabled as the driver claims not to support this feature. If the member is running in Ether/POSChannel mode, traffic may still be received on this member - this may breach configured QoS policies and will prevent an mLACP brute-force switchover from taking place.), (Recommended Action: Shut and no-shut the member interface may clear the condition. If the error persists, manually shutting the member interface will prevent any QoS breaches.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-REMOTE_SLAVE_LEFT_LOOPBACK ### Response: (Severity: 6), (Category: L2), (Description: While running the link in OAM Loopback mode, with the local peer as the Master, the Slave peer abruptly ended Loopback mode without being told to do so by this peer. This may indicate a problem with the remote peer.), (Recommended Action: No corrective action is required. This peer has exited Loopback mode also, and the link is now back to normal operational status.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBUS-6-HBM_LANE_REPAIR_LANE_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates HBM PHY lane number needing repair/), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-4-TIMER_ADDL_CTXT ### Response: (Severity: 4), (Category: IP), (Description: The IPV6 MA process failed to add context to timer.), (Recommended Action: Restarting ipv6_ma may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_CONFIG-7-ERR_MUTEX_DESTROY ### Response: (Severity: 7), (Category: OS), (Description: A internal mutex destroy operation has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_LIB_TOKEN-7-DEBUG_REGISTER ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when registering debug.), (Recommended Action: This is not a critical error and it can be ignored.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-DEVCTL_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric Status Database server (FSDB) failed to read a rommon variable.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLICE_MGR_PROXY-3-SLICE_OPER_STATE_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Indicates that a fault occured during a change in oper state of slice.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_VLAN_EA-3-HSRP_SUPPORT ### Response: (Severity: 3), (Category: PLATFORM), (Description: HSRP is not supported if - hw-module vrrpscale enable - is not configured), (Recommended Action: Please capture the complete error log. Please check the data sheet for the supported configuration. Please contact TAC for any support on this) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-USER_OP ### Response: (Severity: 6), (Category: PLATFORM), (Description: The given user requested the given operation for the given location.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-3-POOL_STATUS_UNKNOWN ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: BFM encountered an pool state error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-4-WTX_MSG ### Response: (Severity: 4), (Category: ROUTING), (Description: WAIPC related message), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-6-NBR_NOPOLICY ### Response: (Severity: 6), (Category: ROUTING), (Description: No routing policy has been configured for the specified eBGP neighbor in the given direction (inbound or outbound) for the address family named. To avoid unintended routing effects, no prefixes will be accepted in that direction until some policy is configured. 'Policy' can be a route-policy, or (for inbound policy) it can be a prefix list.), (Recommended Action: Configure a route-policy for the neighbor in the given direction. If the desired behavior is to accept/send all routes, the route-policy should contain the single statement 'pass'. If the desired behavior is not to accept/send any routes, the route-policy should contain the single statement 'drop'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-4-ERR_RETRY_INIT ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure LDP discovery transport address? ### Response: To configure the LDP discovery transport address, use the 'discovery transport-address' command under the MPLS LDP interface configuration. RP/0/RSP0/CPU0:router(config)#interface GigabitEthernet0/0/0/0 RP/0/RSP0/CPU0:router(config-if)#mpls ldp discovery transport-address 192.168.1.1 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_HEAP-7-BAD_HEAPPAGE ### Response: (Severity: 7), (Category: HA), (Description: A heap page address is misaligned or lies in some invalid range.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-1-UC_LO_OVR_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Unicast low priority fifo overflow error), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-4-INSTALL_ERROR ### Response: (Severity: 4), (Category: MGBL), (Description: An error was encountered while the Central Configuration Validator (CCV) was attempting to check if files or libraries upon which it is dependent were changed in an install operation. Any changes found would have prompted CCV to restart.), (Recommended Action: The problem may be caused by system resource limitations. Attempt to address any resource limitations before proceeding. If files or libraries upon which CCV is dependent have recently been changed, or if further problems are seen, try restarting the process using the 'process restart ccv' command. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_STORM-4-SC_DELETE_WARN_IFH ### Response: (Severity: 4), (Category: PLATFORM), (Description: Resets storm control config on this main interface across all BDs), (Recommended Action: Provision fresh storm control configs to police the traffic again) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-EVPN_ROUTE_TYPE_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: Unsupported route type update received.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QAD_QUEUE_MODEL-3-SHMWIN_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Shared memory access operations like init,open or bind might have failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-4-BER_SD_ALARM ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message provide information that Signal Degrade BER (Bit Error Rate) alarm is set or cleared on a specific port based on the BER configuation. port: on which alarm is set/cleared status: set/cleared), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - sh running interface <> - sh controller all - show tech-support ethernet interface location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SEIPC-3-OPERATION_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Encountered an error in debug module. This error should not impact the major functionality of the module. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize modules. Typically, this occurs when the software tries to initialize the modules. - Failed to shutdown modules. Typically, this occurs when the software tries to shutdown the modules.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-3-SYNC_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: Failed to perform standby sync operation), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_STORM-3-SC_EXIST_ERR_INTF_NAME ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to program storm as it is conflicting with an existing AC), (Recommended Action: Remove storm control config on this sub-interface) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-3-PROC_SM_TIMEOUT ### Response: (Severity: 3), (Category: L2), (Description: BFD proc SM timed out because of state timer expiry.), (Recommended Action: Restart corresponding bfd process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-3-TTY_NMSPC_PATH ### Response: (Severity: 3), (Category: IP), (Description: 'Unable to get the sysDB path of an item from TTY nmspc library'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-LWA_ADD_DIR_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: A file with the same name as aaa directory detected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE-7-FTRUNCATE_ERROR ### Response: (Severity: 7), (Category: OS), (Description: ftruncate system call returned an unexpected error Debug trace buffer initialization failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WDMON-3-PM_REPORTED_BAD_STATUS ### Response: (Severity: 3), (Category: INFRA), (Description: Sysadmin process manager reported bad status. Sysadmin will reboot if the system is unable to correct this condition on its own.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_RC_HEX ### Response: (Severity: 3), (Category: SECURITY), (Description: Error description, hex_code of rc.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: Multilink_CLNT-3-CMD_RETURN ### Response: (Severity: 3), (Category: L2), (Description: Could not retreive bundle info. Returned error while handling Network to Host endianness.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-3-FMI_NETIO_DROPPED_PACKETS ### Response: (Severity: 3), (Category: SECURITY), (Description: An error has occured during packet handling in the FMI base capsulation, and no error counters can be updated. If errors are seen for an extended period then it can be assumed that no packets can be forwarded through FMI interfaces. This is likely to be a symptom of a problem in the Packet Forwarding Infrastructure - earlier error messages might indicate the root cause of the problem.), (Recommended Action: If the errors stop after a couple of minutes while traffic is still flowing through the FMI then it can be assumed that the problem has resolved itself. If the problem continues, then unconfiguring and reconfiguring the FMI interfaces could fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-EVM_MSG_ATTACH_FAIL ### Response: (Severity: 7), (Category: OS), (Description: Dumper attaches various callbacks with resource manager. Failure to register event callback functions might lead to unexpected behaviour of dumper.), (Recommended Action: Please collect the following data and contact support. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. follow process 6. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-FMEA_BOARD_POWER_FAILED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_IR0_INTR_PKT_EOP_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_IR0_INTR_PKT_EOP_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEATURE_LPTS-3-DOUBLE_FREE ### Response: (Severity: 3), (Category: FABRIC), (Description: A software error occurred, when the PA attempted to double free the FGID), (Recommended Action: No action required Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INVMGR-3-ERR_OBJECT_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates a failure in creating the object for the specified slot. The entry is not added to the inventory. %s - indicates an internal message), (Recommended Action: Issue may be due to lack of memory in the system. If memory shortage is the cause, reduce other system activity to ease memory demands and restart process invmgr via CLI 'process restart invmgr' to recover. If conditions warrant and minimum memory requirements not met, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIF_MA_DEBUG-3-DEBUG_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: debug library initialization failed), (Recommended Action: System will automatically retry initialization and no further user action is necessary. If problem, persists, please contact Cisco TAC for support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ACL_PARSE-7-ERR_MEM_ALLOC ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_4_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-6-TTY_MGMT_REG_OPTIONS ### Response: (Severity: 6), (Category: MGBL), (Description: The call to tty_mgmt_register_tty_options() failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-RX_ALARM_RAI ### Response: (Severity: 3), (Category: PLATFORM), (Description: The BITS receiver has detected RAI defect for incoming signal. Receiving remote alarm indication(RAI) means the far-end equipment over the T1/E1 line has a problem with the signal it is receiving from the upstream equipment.), (Recommended Action: Verify input BITS clock signal is set up correctly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL2-3-MSG_SEND_FAIL ### Response: (Severity: 3), (Category: OS), (Description: A call to function for sending BCDL msg to consumers failed. This could lead to inconsistency between BCDL producers and consumers.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMS-4-EMSD_PORT_RANGE ### Response: (Severity: 4), (Category: MGBL), (Description: The configured port is outside of the range and will consume an additional LPTS entry.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-TASKID_COMPARE_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: 'nvgen_server got an error from calling aaa_compare_tasktable_alt.'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDLD-4-MUTEX_LOCK_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: A mutex lock acqure failed in the api context, for UDLD lib around the line number specified in error message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support control ethernet fast location , dumpcore running location , console log for 1 hour before and 1 hour after this error message printed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support control ethernet fast location , dumpcore running location , console log for 1 hour before and 1 hour after this error message printed output, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-SHUTDOWN ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node will be brought down because a critical environmental alarm occured.), (Recommended Action: Check air-flow, fan trays, and make sure that chassis is well-cooled. Manually boot up the node once the chassis has been checked.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-3-ERR_INTF_INIT ### Response: (Severity: 3), (Category: L2), (Description: CDP is unable to run on the specified interface. It is likely that this is due to a lack of available resources.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Configuring 'cdp disable', 'cdp enable' on the interface, or restarting CDP on the affected node may recover the situation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPC_I2C-7-BUS_HANG ### Response: (Severity: 7), (Category: PLATFORM), (Description: An I2C bus hang has been detected. Recovery is automatically attempted. Should the recovery be successful, a BUS_UNHANG_SUCCESS message is issued; otherwise, an UNRECOVERABLE_BUS_HANG is issued.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_PLAT_PROPS ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error communicating with the Platform Properties DLL. The error message describes what operation has failed and why it failed. This will either have occurred because the Platform DLL failed to be properly initialized, or because of some error occurring in the platform dependent code.), (Recommended Action: In many cases, PPP MA will recover by itself. If it does not then restarting the process may help. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that a failure has occured in Shelf Manager, but there is not corresponding error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-MKDIR_FAILED ### Response: (Severity: 7), (Category: OS), (Description: system call failed. Dumper might get impacted by this.), (Recommended Action: Restart the dumper process. If the issue still exists, Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-3-OTN_LICENSE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Necessary license for G709 is not found.), (Recommended Action: Purchase and install a valid license for G709. If a valid license is already installed or issue persists after installing the license, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - sh platform - sh processes vic location <> - show tech-support ethernet interface) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLICE_MGR_PROXY-3-SYSDB_REG_NOTIFY_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Registration fail for sysdb notification), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-7-GENERIC_ERROR ### Response: (Severity: 7), (Category: SECURITY), (Description: Generic error message used for internal debugging.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VRRP-6-INFO_STATECHANGE ### Response: (Severity: 6), (Category: IP), (Description: The VRRP router has changed state.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_RECV_BAD_TE_MSG ### Response: (Severity: 3), (Category: ROUTING), (Description: The process has received a TE message with invalid contents. As a result, the TE message is ignored and TE tunnel may not come up.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-3-ALARM_NOT_GENERATED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Wait for dlls to get loaded since usb pkg is loaded before infra/watchdog (wdsysmon).And it wait for the disk to be mounted. Register with wdsysmon for diskspace monitoring. This error message will get printed when it unable to open path to register for diskspace monitoring and when no alarms are generated if configuration filesystem runs out of diskspace.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PM-6-TFTP_DISABLED ### Response: (Severity: 6), (Category: MGBL), (Description: This is an informational message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-4-WARNING_LOGIN ### Response: (Severity: 4), (Category: SECURITY), (Description: The sshd encountered a warning condition.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ITCAM-3-no_entries ### Response: (Severity: 3), (Category: PLATFORM), (Description: Internal TCAM entries have been exhausted and cannot meet the current request.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_LQ_PKT_LEN_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue packet length error on XAUI 1 LQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC11 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-5-ANR_UP ### Response: (Severity: 5), (Category: SERVICES), (Description: 'The autonomic network registration authority ' 'has been confgiured and is locally up'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-HB_SEND_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: SIM heartbeat sent to Service Engine failed, reloading), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-1-ECU_FAIL ### Response: (Severity: 1), (Category: MEDIASVR), (Description: This ios_msg is raised upon failure to retrieve serial number from the inserted ECU Disk.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IEP-3-DAEMON_ERR_SYSMGR_PROC_READY ### Response: (Severity: 3), (Category: IP), (Description: An error occurred while signalling that initialization was complete.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPP_ASYNC_FIFO_MBE ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPP packet Async FIFO multiple bits error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure LDP loop detection? ### Response: To configure LDP loop detection, use the 'loop-detection' command under the MPLS LDP configuration. RP/0/RSP0/CPU0:router(config)#mpls ldp RP/0/RSP0/CPU0:router(config-ldp)#loop-detection <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-UNEXPECTED ### Response: (Severity: 7), (Category: HA), (Description: An unexpected condition encountered. This is not necessarily an error.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-PTHREAD_MUTEX ### Response: (Severity: 3), (Category: OS), (Description: The mutex lock/unlock failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ADJ_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error: Cannot create the adjacency for a particular interface. Will retry for few times), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-1-MC_LO_MBE_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Multicast low priority fifo multi-bit ECC error), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-QUICK_MODE_TIMER_EXPIRED ### Response: (Severity: 3), (Category: SECURITY), (Description: We can't wait forever before we start quick-mode and initiate phase II.), (Recommended Action: 'The most likely reason for failing to start phase2 is that the process failed to complete phase1. In this case, it should have also logged another message which should appear immediately before this one.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-7-VERIFY_APPLY_FAIL ### Response: (Severity: 7), (Category: ROUTING), (Description: The policy_repository process, while verifying a change to a policy, encountered an error while checking the validity of the change in the policies that are applied by that policy.), (Recommended Action: Fix the offending argument in the applied policy so that it is accepted by the client (i.e. BGP, OSPF, etc.) If problem ins not fixed, please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP weight attribute and what is its range? ### Response: The weight attribute is Cisco proprietary and is local to the router. It has the highest preference in the BGP best path selection process. The range is 0-65535 and paths with a higher weight are preferred. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_CFEC_LOL ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-XBAR_TIMEOUT_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected an crossbar timeout error on link 2), (Recommended Action: This alarm is transient and should auto-clear when error condition is resolved. If the alarm doesn't clear, then please reload the card using command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB_ALARM-3-L2FIB_ENTRY_LEAK ### Response: (Severity: 3), (Category: PLATFORM), (Description: L2FIB entry leaked resource. The resource cannot be recovered without user intervention), (Recommended Action: If leak does not become service impacting -- none. Otherwise, service impacting recovery methods must be taken. Crashing the l2fib_mgr process on the linecard where the leak was detected will recover the mac resource.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_VPLS-6-LTRACE_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the ltrace module in the platform L2FIB VPLS component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-FAILED_LC_RELOAD ### Response: (Severity: 0), (Category: PLATFORM), (Description: PRM has detected an unrecoverable error. The linecard will be reloaded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-RX_MAX_LEN_ERR_FIA01 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet maximum length error FIA 01 interface.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_OUT_MEM_UCORR_ECC_ERROR_LNK1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast output memory uncorrectable ECC error on link 1), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-4-DEBUG_INIT ### Response: (Severity: 4), (Category: IP), (Description: The IPV6 MA process failed to initialize debug support), (Recommended Action: Restarting ipv6_ma may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHER_CTRL-6-PRINT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Print the static/decode data information.), (Recommended Action: This is informational print only, no action to be taken.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_0_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp bestpath cost-community ignore' command in IOS XR BGP configuration? ### Response: The 'bgp bestpath cost-community ignore' command is used to ignore the cost community for best path selection. The cost community is a non-transitive extended community attribute that can be used to carry the cost of a route. By default, if the cost community is present, BGP will use it in the best path calculation. This command disables the use of the cost community in best path selection. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_THOR_L2FIB_ATOM-3-INIT_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the ATOM module in the platform L2FIB ATOM component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PM-3-COMMUNICATION_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The specified device has a fault that affects the card functionality. The card node will be reset and ideally or waiting to be debugged if the card node is in NMON mode. When action is reset, the problem will not happen again when it comes back up.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTR9 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP-3-CACHE_FAIL ### Response: (Severity: 3), (Category: IP), (Description: ARP has overwritten an interface entry with a static or alias entry. This indicates a conflict with the IP address configuration on the interface.), (Recommended Action: Reconfigure the static ARP entry or the conflicting interface IP address. If this does not help then do the following. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-MRIB_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error has occurred during communication with the MRIB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show mrib client error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show mrib client error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-5-DEVICE_INCONSISTENT ### Response: (Severity: 5), (Category: MEDIA), (Description: The media storage card specified is inconsistent between the partition table and the file system format. This inconsistency needs to be corrected and the contents formatted correctly.), (Recommended Action: Verify that media device was formatted. If not, then format media device manually. If it still fails, replace media device.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option explicit name feature? ### Response: The MPLS TE path-option explicit name feature allows an MPLS TE tunnel to use a named explicit path configured separately from the tunnel. A named explicit path is a reusable path definition that can be applied to multiple tunnels. It provides a way to define explicit paths independently of tunnel configurations. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-XAUI_1_FRAG_ERR_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: XAUI interface to NPU-1 reported fragmentation error on TX side on bridge instance - 3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VS_PUBLISHER-3-TIMEOUT ### Response: (Severity: 3), (Category: INSTALL), (Description: There was a problem processing the notification of a change to the selected version for one or more communication protocols.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_SW-3-ERR_READ_PUNT_REASON_FAILED ### Response: (Severity: 3), (Category: IP), (Description: The IPv6 NetIO component was unable to read the Packet Punt Reason supplied by the Hardware forwarding component. The Packet was dropped.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKIMIB-3-TRAP_INIT_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failure could be registering for trap enable/disable callbacks or creating lwm channel.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFI_EA-4-ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: The SFI EA process failed to initialize a critical component. The process cannot proceed and will restart to recover.), (Recommended Action: The process should recover automatically and no further action is required. If problem persists, it is suggested to collect 'show tech-support infra/sfi' and 'show running-configuration' and contact Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS LDP session protection feature? ### Response: The MPLS LDP session protection feature provides a means to protect an LDP session between directly connected neighbors in the event of an interface failure. It uses a targeted hello adjacency as a backup to maintain the session. It is enabled with the mpls ldp session protection command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLU-4-TBM_HW_INIT_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: A particular table failed to initialise. This is typically due to incorrect parameters supplied when initialising the table. Any traffic on that table is impacted.), (Recommended Action: Please collect the following output on the affected node. - show logging - show tbm trace error/event/all - show asic-errors pse <> all location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-NOMEMORY ### Response: (Severity: 3), (Category: INSTALL), (Description: The requested operation could not be accomplished because of a low memory condition.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-bandwidth max and min feature? ### Response: The MPLS TE auto-bandwidth max and min feature specifies the maximum and minimum bandwidth values that auto-bandwidth can request for a tunnel. The max value limits how high auto-bandwidth can adjust the tunnel bandwidth, while the min value specifies the lowest bandwidth auto-bandwidth can request. These values constrain the auto-bandwidth adjustments. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-4-TUNNEL_OVER_TUNNEL_UNSUPPORTED ### Response: (Severity: 4), (Category: ROUTING), (Description: --), (Recommended Action: Change configuration/topology to avoid this.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-REPLY_ERR ### Response: (Severity: 3), (Category: SYSDB), (Description: Sending error reply to client.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBIMGR-3-FAILED_TO_CALCULATE_MD5 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Either the path is invalid, or the infrastructure is behaving incorrectly. The MBI operation in progress may not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-WRITE_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Most probably some problem with the file system), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install verify packages command in IOS XR? ### Response: The 'install verify packages' command is used to verify the consistency and integrity of the currently active software packages on the router. It checks for any missing or corrupted files and reports any issues found. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-4-INVALID_NOTIF_INFO ### Response: (Severity: 4), (Category: INSTALL), (Description: The Install Helper failed to extract the notification information.), (Recommended Action: Install helper failed to obtain a local directory name. This error will be recovered automatically. No user action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-UPGRADE_LICENSE_TERM_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The term of the upgrade license has expired.), (Recommended Action: The customer should reserve a valid license.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_SYSDB_BAG_REG ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: adminexec-3-EVENT_BLOCK ### Response: (Severity: 3), (Category: MGBL), (Description: The call to event_block() failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-3-IDT_FAILED ### Response: (Severity: 3), (Category: HA), (Description: An error occurred during checkpoint Initial Data Transfer which resulted in its failure. A retry of IDT will happen automatically.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_BMADJ-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: PLATFORM BMADJ, Information), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB_SNOOP_FRETTA-6-ERR_EXCEED_MAXIMUM_OLE ### Response: (Severity: 6), (Category: PLATFORM), (Description: The route (S,G) has hit the maximum number of OLEs local to this LC. No more OLEs beyone maximum support number will be hardware programmed. clear pim topology ), (Recommended Action: No action is required. Platform software will not program OLEs beyond scale) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-3-TIMER_PROBLEM ### Response: (Severity: 3), (Category: OS), (Description: Problem with timer events. This will impact dumper functionality as the dumper configuration syncronization relies on timers.), (Recommended Action: Please restart process dumper. If the issue is seen even after process restart then, Collect the following data and raise DDTS. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PMLIB_CLIENT-4-WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: svc pmlib client encountered an provisioning warning.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect 'show log location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC_CTRL-3-FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that a failure has occured in DSC-CTRL process.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the dsc process is up and running by executing the following command at the CLI of the active RP: 'show process dsc' If it is still non-operational, restart the driver by executing the following command at the CLI of the active RP: 'process restart dsc' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HPI-3-SW_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A software programming error has occurred which driver cannot recover), (Recommended Action: Check the trackback and make sure the access is correct.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_UV-3-CERR_REG_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during the registration of OSPF error codes.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBSOC-0-SVC_EMERG ### Response: (Severity: 0), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-INVALID_IFNAME ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The interface name does not correspond to a valid XR interface.), (Recommended Action: Check the XR interface names in the XR_INTERFACES environment variable.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: 8000-1-RESTART_NOT_SUPPORTED ### Response: (Severity: 1), (Category: PLATFORM), (Description: This is an error message in the DPA module to indicate that a process that doesn't support restart has been restarted (crash, CLI or SMU installation) Process will trigger node reload to recover after collecting required information in the linecard's disk), (Recommended Action: Please collect the core file and DPA traces from linecard's disk Ignore this if process was operationally restarted like process restart command or process restart SMU installation those operations are not supported yet and nothing to debug at this point) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-1-PARTIAL_CHASSIS_SHUTDOWN_POWERUP ### Response: (Severity: 1), (Category: PLATFORM), (Description: Received message from environment monitor that the voltage is low on the power shelves. So we are shutting down linecards and fabric cards to prevent damage to these boards.), (Recommended Action: Examine chassis and replace battery or power-shelf.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-EDM_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured with a show client communicating with the msdp. show server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging processes msdp error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging processes msdp error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show context command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show context output, call your Cisco technical support representative and provide the representative with the gathered information. from the node obtained from the above command, run the following command: Copy the error message exactly as it appears on the console or in the system log. Issue the show sysdb trace edm command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show sysdb trace edm output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_9_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_9 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'route-policy' command in IOS XR L3VPN configuration? ### Response: The 'route-policy' command is used to define routing policies for importing and exporting routes between VRFs and the global routing table. It allows you to filter and manipulate routes based on various criteria such as prefix, community, and AS path. Route policies provide flexibility in controlling the exchange of routing information in an L3VPN. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIB-3-SYSDB_ACCESS ### Response: (Severity: 3), (Category: SNMP), (Description: The MIB had trouble reading from or writing to or binding/unbinding SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SM-3-CALLBACK ### Response: (Severity: 3), (Category: INSTALL), (Description: This self-managing component reached an unexpected state, and was unable to proceed with the requested operation.), (Recommended Action: Please retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVM-4-LEVM_DISABLE_FD ### Response: (Severity: 4), (Category: OS), (Description: EVM received an error from LEVM when disabling fd), (Recommended Action: This is an internal error and should be reported to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-REG_CALLBACK_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'AIB Callback registration failed.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists.' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure BGP route damping for MPLS L3VPN? ### Response: To configure BGP route damping for MPLS L3VPN, use the 'dampening' command in BGP VPNv4 configuration mode. router bgp 65000 address-family vpnv4 unicast vrf MyVRF dampening <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_8_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_LOCSW-7-DEBUG_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB LOCSW component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-CONVERGE_VERSION_MISMATCH ### Response: (Severity: 3), (Category: ROUTING), (Description: A client updated the RIB for convergence but not with the latest version as known by RIB. This will have delayed or prevented the convergence of the routing table, and hence the purging of any stale routes from the forwarding table.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_FT_OIR ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when any FT is OIR'ed from satellite.), (Recommended Action: Please reinsert the FT back in the satellite.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-EVENTLIST ### Response: (Severity: 4), (Category: MGBL), (Description: An error occurred invoking an MDA function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_MGR-3-SERVICE_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FGID driver failed service initialzation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR_DLL-2-CRIT_INT_MCH_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A critical error has occurred in the MCH (Memory Controller Hub) of the Linecard's CPU complex. The message will display the name, description, and error log. These errors will cause a card reload. If it is a software error and persists or if it's a hardware error, please contact support.), (Recommended Action: If it is a software error and persists or if it's a hardware error, please contact support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-ERR_GENERAL_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: 'Parser encountered error, see message for more details'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_NETIO-3-MEMORY ### Response: (Severity: 3), (Category: L2), (Description: The DLL has failed to acquire the required amount of memory. There might be some other process consuming more memory which creates memory shortage for this.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-6-INFO ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message in the OPTICS driver to indicate an operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-ERR_REPROGRAM_POLICERS ### Response: (Severity: 7), (Category: OS), (Description: It failed to reprogram a flow policer when it had received a request to reprogram all flow policers to HW.), (Recommended Action: When this issue happens, it will trigger an automatic restart. Check the status of Metro IPC Server because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_AUTO_TUN_P2MP_DEST_LIMIT_EXCEEDED ### Response: (Severity: 3), (Category: ROUTING), (Description: The creation of the P2MP auto-tunnel destination aborted since it would have exhausted the tunnel destination scale limit), (Recommended Action: Reduce the P2MP configured/auto tunnels to below the system scale limit) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-VSA_FORMAT_ERR1 ### Response: (Severity: 3), (Category: SECURITY), (Description: VSA format error in daemon user config.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does IOS XR handle configuration failures during router startup? ### Response: During router startup, if there are configuration failures, IOS XR boots with the last known good configuration instead of the latest changes. This ensures that the system comes up in a consistent state even if recent configuration changes caused issues. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-TRAPSEND ### Response: (Severity: 3), (Category: SNMP), (Description: A trap destined for the given address could not be sent. This could be due to a low memory condition. It also might be due to the fact that there is no SNMP transport process(udp process) running for that transport protocol.), (Recommended Action: Check the running processes to ensure that an udp process is running. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cds_proxy-3-NULLARG ### Response: (Severity: 3), (Category: OS), (Description: A NULL pointer was passed as a fn parameter), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_7_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-2-CRIT_EXIT ### Response: (Severity: 2), (Category: L2), (Description: An critical error occurred in NPU Driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-4-XCVR_FAULT ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message provides information about the fault occurred on the interface.), (Recommended Action: The message is just for information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-FAILED_TO_CREATE_SKEYID ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to generate SKEYID.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_TDM-7-BAD_ALIGNMENT ### Response: (Severity: 7), (Category: HA), (Description: A heap index was not word aligned.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_1_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_1 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGPTE_LIB-2-DATA_QUEUE_FULL ### Response: (Severity: 2), (Category: ROUTING), (Description: The IGP-TE inter-process message queue is full and further messages cannot be accepted. This may impact TE functionality if the condition persists.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ACL-6-IPACCESSLOGDP ### Response: (Severity: 6), (Category: ACL), (Description: Packet matching the log criteria for the given access list was detected.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-ERR_FILE_ATTACH ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred when bgp try to do event file attach.), (Recommended Action: In most cases the problem will recover by resetting the neighbor for which file attach is failing.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-3-ASYNC_SOCKETS_DISALLOWED ### Response: (Severity: 3), (Category: IP), (Description: The socket library has disallowed creation of a new socket. The system is likely undergoing churn or is throttled, so that new sockets are no longer being allowed. Once the system gets back to stability, socket creation will be allowed.), (Recommended Action: The information in required_info to be collected and engineering team to be notified. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_SERVER-3-XSVF_ERROR ### Response: (Severity: 3), (Category: L2), (Description: ASIC scan server xsvf execution encountered an error condition, this is because of illegal command), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_FWD-3-BAG_REG_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Some error occured while trying to register edm bags. The text of the message displays the failed operation with error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-6-INFO_MSG ### Response: (Severity: 6), (Category: L2), (Description: This is a informational message in the PSE Driver to indicate an operation.), (Recommended Action: No action is required. Collect the error message and required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-4-RIB_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: An error has occurred during communication with the RIB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show rib trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show rib trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging processes msdp command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging processes msdp output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN-3-UNKNOWN_ASIC_ID ### Response: (Severity: 3), (Category: L2), (Description: The ASIC Id is not valid and the process will abort), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPV6-3-MCASTJOIN ### Response: (Severity: 3), (Category: IP), (Description: Failed to join a multicast group on the interface.), (Recommended Action: Restart the dhcpv6d process Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_MA-3-IFH_BW_UPDATE_RATE ### Response: (Severity: 3), (Category: QOS), (Description: The QoS MA process encountered the specified error while trying to update it's database with the new bandwidth update from ANCP or Ifmgr.), (Recommended Action: Contact TAC with required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_V6FIB_RP-3-ERR_INFO_VERBOSE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error information during improper updation of variables or incorrect return stated in IPV6 FIB platform), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_ACL-6-IPACCESSLOGP ### Response: (Severity: 6), (Category: ACL), (Description: A packet matching the log criteria for the given access list was detected. These messages are issued whenever access lists are configured with the 'log' option and matches with the IP protocol type TCP (or) UDP (or) SCTP. This message is seen for the first match and for each match after the hit count is greater than 0x7FFFFFFF(2147483647).), (Recommended Action: This is information only message, no action required No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-CORRUPT_ARG ### Response: (Severity: 7), (Category: INSTALL), (Description: Value of a parameter passed to function appears to be corrupt. The current request or operation may not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-CF_MBE_ERR_FIA10 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA10 channel FIFO multi-bit error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVM-1-FLAGS ### Response: (Severity: 1), (Category: OS), (Description: An Event Manager call was made with an invalid flag argument.), (Recommended Action: This is an internal error and should be reported to TAC. The application process making the call has corrupted data or some other internal error. The application should be restarted; if that fails, the router should be rebooted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_7_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_7 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FILECOPY_LIB-3-NOMEM ### Response: (Severity: 3), (Category: OS), (Description: No memory to perform bag operations.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_9_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_6_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-READERINIT ### Response: (Severity: 7), (Category: MGBL), (Description: An error occurred while preparing to read instructions from the command line.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-7-TOO_LONG_NAME ### Response: (Severity: 7), (Category: OS), (Description: Too long name is specified), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is pseudowire redundancy and how is it configured in Cisco IOS XR? ### Response: Pseudowire redundancy provides the ability to configure backup pseudowires for VPWS services to protect against failures of the primary pseudowire or the remote PE router. It is configured using the 'backup' command under the 'p2p' configuration mode. The 'neighbor' command is used to specify the backup PE router and the 'pw-class' command is used to specify the backup pseudowire attributes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_0_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_0 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-CARD_BOOT_TIMEOUT_FAULT ### Response: (Severity: 3), (Category: DRIVER), (Description: Card is reporting boot timeout has expired. This is a fatal failure condition that might point to HW problem. CCC driver state machine will try to recover from the failure by reloading the card.), (Recommended Action: If CCC driver power-off the card because the problem persist after all the recovery reloads have failed, then contact with Cisco support team.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-7-HBLOSS_COLLECTION_IGNORED ### Response: (Severity: 7), (Category: PLATFORM), (Description: The current request to collect heatbeat loss log is being ignored because of another instance of heatbeat loss log collection that is still in progress.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BAG_SCHEMA-4-ERR_DEBUG ### Response: (Severity: 4), (Category: INFRA), (Description: Bag Schema Server encountered an error using the debug service. The error message describes what operation has failed and why it failed. The error could be caused by low memory resource or programming error.), (Recommended Action: In many cases, Bag Schema Server will recover by itself. If it does not then restarting the process may help. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EDRM_CLIENT-3-SHM_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: EDRM shared memory context init error), (Recommended Action: Process will exit due to shm memory init error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_4_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_4_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_4 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-TX_ALARM_TMF_SYNC_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Condition raised possibly due to incorrect internal BITS transmitter configuration.), (Recommended Action: Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-3-CBC_OFFLINE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The node CAN Bus Controller is currently offline. Operations such as environmental monitoring, hardware power control and card reset may be impaired.), (Recommended Action: 1- Issue the following process restart commands in sequence and then see if the error message goes away and 'show platform' CLI indicates a valid card type: process restart can-server location process restart shelfmgr location 2- If the issue is not yet resolved, please reseat the affected card carefully, making sure it is fully inserted into the backplane. Try different slots in the chassis if needed. See if the error goes away and if the card boots up and reaches the XR RUN state. 3- If the error persists, please contact your Cisco technical support team.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-6-AGENT_ALREADY_REGISTER ### Response: (Severity: 6), (Category: LICENSE), (Description: Smart Licensing has already registered with Cisco, use the force option to register again.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLICE_MGR_PROXY-2-SW_FAULT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Slice Mgr Proxy process detected a fault in the hardware, or software on the LC.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: an external API has failed in Shelf Manager. The details are supplied with the msg.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REPLICATOR-3-IDT_FAIL ### Response: (Severity: 3), (Category: LIBRARY), (Description: The replicator has repeatedly failed to complete IDT for a system data handle. There may be problems with communications or other low-level infrastructure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-BATCH_CONFIG_FAIL ### Response: (Severity: 3), (Category: MGBL), (Description: Some configurations can not be handled correctly because: - invalid configuration - configuration can not be accepted at this moment), (Recommended Action: Use 'show configuration failed' to see all the failed configurations.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-NEGCOUNTER ### Response: (Severity: 3), (Category: ROUTING), (Description: The counter value for accepted prefixes is wrong and less than zero), (Recommended Action: The counter can be corrected by resetting the session. However, the only behavior affected by an incorrect counter is enforcement of the 'max-prefix' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPCD-3-INIT ### Response: (Severity: 3), (Category: IP), (Description: A failure occurred during the initialization of the process. This may have resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-SUBMODE ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to parser_submode_find failed to find submode. The error is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is an SMU in the context of IOS XR? ### Response: SMU stands for 'Software Maintenance Upgrade'. It is a software patch delivery mechanism that provides a point fix for a critical issue in a specific IOS XR software release. SMUs are release-specific and can be installed and activated to address critical bugs without performing a full image upgrade. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-4-ERR_CHKPT_CORRUPT ### Response: (Severity: 4), (Category: L2), (Description: Whilst restoring one of its checkpoint tables MFR MA found a corrupt checkpoint entry. The entry will be ignored and so the relevant interface's MFR session will be renegotiated after the restart and as a result there may be a short period where traffic is lost.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_INVALID_MACRO ### Response: (Severity: 3), (Category: FABRIC), (Description: Unexpected macro type value read from ASIC. There could be a h/w or FPGA issue.), (Recommended Action: Collect all the event logs and 'sh controller fabric trace driver all location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-3-CONFIGURATION_SYNC ### Response: (Severity: 3), (Category: SYSDB), (Description: Sysdb detected possible configuration inconsistency and successfully cleared it.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_COFO_LB-4-ERR_INT ### Response: (Severity: 4), (Category: L2), (Description: An internal software error occurred in the collapsed bundle dll.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_HEAP-7-BAD_HEAPPTR ### Response: (Severity: 7), (Category: HA), (Description: Internally heap pointers are kept as offset indices. A given heap pointer was found to be outside the heap.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-REPLACE_COMMIT_NOT_COMMITTING ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that install commit as part of the replace operation is not attempted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-RX_ALARM_INVALID_10M_CLOCK_SYNC_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: The 10MHz UTC clock signal has been invalidated possibly due to loss-of-signal condition, offset out of range or phase lock issue.), (Recommended Action: 1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 10MHz clock is applied at input port.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-ISSU_NODE_BOOT_NOT_ALLOWED ### Response: (Severity: 4), (Category: INSTALL), (Description: Node rebooted while ISSU install operation is in progress, it will not be allowed to come up until the operation completes.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-7-ATTACHPOINT_MISMATCH ### Response: (Severity: 7), (Category: ROUTING), (Description: The policy_repository process was not able to extract the policy name OR id value for this attach point path. This means that the policies that are actually using this attach point will NOT be recorded and thus policies *could* be deleted while still in use.), (Recommended Action: Restart the policy_repository and check for re-occurence of issue Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Information during improper updation of variables or incorrect return state in MPLS FIB platform), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: attestation_agent-2-IMA_BLOCK_SIGN_VALIDATION_FAILED ### Response: (Severity: 2), (Category: MGBL), (Description: A failure occurred during Runtime integrity validation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_UV-3-ERR_VRFN_FNS_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: The ospfv3_uv process was unable to initialize SysDB callbacks.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL_GRE_EA-3-DELETE_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the platform specific code software to indicate anomolies while initializing GRE Feature. This error is most likely caused by a temporary situation within the feature code. %s - indicates the reason for the failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-CCC_THREAD_INIT_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: An attempt to initialize a connection to the CCC driver failed. This is a fatal fault since ESD would not be able to interact with CCC driver. ESD process will restart after this fatal error.), (Recommended Action: If this problem does not recur, no intervention is required. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ICMP-7-EVM_CREATE_FAILURE ### Response: (Severity: 7), (Category: IP), (Description: The IP ICMP library could not create the event manager to handle the events to be received by the process. This can happen when the process is (re)starting. If the error message doesn't persist, it can be ignored. If the error message persists, some basic icmp functionality may not be available.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action.If does not recover contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-PHASE2_PROPOSAL_NOT_CHOSEN ### Response: (Severity: 3), (Category: SECURITY), (Description: Phase-II parameters negotiation failed with peer.), (Recommended Action: 'Contact the remote peer's administrator') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-CONFIG_POLICER_MEMORY ### Response: (Severity: 3), (Category: OS), (Description: There is insufficient memory for the policer configuration. All flows will be assigned default characteristics.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-7-MSG_SEND_FAILED ### Response: (Severity: 7), (Category: HA), (Description: Redcon attempted to call msg_send but it failed.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAK-3-PTCL_LIST_NOT_NULL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A packet header on the free list had a non-NULL particle list.), (Recommended Action: Please collect a core dump of the packet client that emitted the message, or whose pid matches that in the error message with 'exception pakmem on' configured.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-5-NOTICE ### Response: (Severity: 5), (Category: OS), (Description: A normal but significant event has occurred.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPIO_PD-3-FAB_EVM ### Response: (Severity: 3), (Category: PLATFORM), (Description: Fabric server EVM creation failed. Packet path initialization at RP errored.), (Recommended Action: Restart the spio_ma process. 'process restart spio_ma location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-5-TCAM_MISMATCH_REPAIRED ### Response: (Severity: 5), (Category: L2), (Description: This message indicates the completion of the automatic correction following the detection of a mismatch between the LC CPU software view of TCAM content, and what was actually found in hardware. It also marks the start of troubleshooting data collection, the end of which will be indicated by a further 'TCAM_MISMATCH_COMPLETED' log message.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-7-EVM_CREATE_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to create event manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_SYSDB_BIND ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_CFGMGR_ADDDIFFS ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-0-FATAL_INTERRUPT_ERROR ### Response: (Severity: 0), (Category: FABRIC), (Description: FIA fatal error interrupt on FIA), (Recommended Action: If the same error ocurrs again after reload or reset, report the exact error message for further investigation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-CANNOT_PERFORM_FAILOVER ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates that on receving reddrv hbloss from more than half of the cards present in the chassis, a failover is attempted. It got failed as the standby is not ready.), (Recommended Action: Perform a manual switchover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-COLLISION ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Network Processor has detected a memory collision.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBC-2-L2 ### Response: (Severity: 2), (Category: SERVICES), (Description: Log level in sbc app is set to higher than nbb_console_unconditional_log_level. Use errmsg facilty to print error message), (Recommended Action: collect ips and pd trace) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-3-NO_SERIAL_NUM ### Response: (Severity: 3), (Category: LICENSE), (Description: The license manager encountered an error while attempting to read the chassis serial number. Without a valid chassis serial number the license manager will not be able to support licenses locked to the affected chassis. Check the error string to determine what has happened.), (Recommended Action: Please restart the licmgr process command 'admin process restart licmgr'. Another option is reloading the RP card by command 'admin reload'. If the error log message is reoccuring , please collect informaiton using the commands 'show tech-support license ','show license trace platform' and contact your tech support representative and provide them the collected information and exact message as displayed on screen.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-ADR_CONSUME ### Response: (Severity: 3), (Category: OS), (Description: Unable to consume requests from ADR.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-2-FAB1_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: LC CPU controller driver detected fabric parity from RP/RSP.), (Recommended Action: If all other LCs also report this parity error alongwith peer RP/RSP, then check for any bent pins on the RP/RSP for which the problem is reported. Reload the RP/RSP that has the problem. If problem persists, contact support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISK_DRIVER-3-FAILED_TO_ALLOCATE_TIMER_ID ### Response: (Severity: 3), (Category: PLATFORM), (Description: ATA device might report these errors when it unable to allocate event timer id.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPP-6-MSG_INFO ### Response: (Severity: 6), (Category: SECURITY), (Description: Informational message.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_SWITCH-2-HAL_INIT_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Switch HAL initialization failed and process will respawn by its own to recover from this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VI_REPL-7-INIT ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: A failure occurred during the initialization of the Virtual Interface Config Replicator process.), (Recommended Action: The vi_config_replicator process will restart and attempt to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CSI_EA-3-PLATFORM_ERR ### Response: (Severity: 3), (Category: L2), (Description: This is an informational message in the CSI EA to indicate that an error was seen when calling platform functions), (Recommended Action: Please collect the trace,) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPPHA-3-FAILURE ### Response: (Severity: 3), (Category: L2), (Description: A CPP HA failure has been detected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-3-ERR_IPV4_ADDRESS_SCAN ### Response: (Severity: 3), (Category: L2), (Description: A scan of the IPv4 addresses on this interface has failed. This means that IPv4 address information for this interface will not be included in outgoing CDP packets. The neighboring device will not see the IPv4 address information for this interface.), (Recommended Action: Restarting CDP as the address consumer, or the ipv4_ma as the address provider on this node may rectify the problem. proc restart cdp location or proc restart ipv4_ma location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-VRF_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred when creating the vrf context for the shown VRF name. As a result VRF can't be enabled.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-INCONSISTENT_REMOTE_MTU ### Response: (Severity: 3), (Category: L2), (Description: Two remote endpoints of EVPN-VPWS service have signalled inconsistent MTU values. The service cannot be brought up until all MTUs match.), (Recommended Action: Perform network level review, and ensure the correct MTUs are being used.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RAW-3-VRF_INIT ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the RAW process attempts to set up connection with the RSI agent during the startup of raw process.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-LB_DEV_VERSION_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: PHY controller driver version is not compatible with the hardware version.), (Recommended Action: Upgrade the PHY controller CPLD image followed by reloading the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMORB_XMLAGENT-6-TCP_RESTART ### Response: (Severity: 6), (Category: MGBL), (Description: The tcp process is probably restarted which is caught in TCP_Monitor), (Recommended Action: just information message, no action is required) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show rsvp session' command in IOS XR? ### Response: The 'show rsvp session' command is used to display information about RSVP sessions. It shows the session type (LSP or reservation), the destination, the tunnel ID, the RSVP reservation style, and the bandwidth reserved. This command is useful for verifying the RSVP sessions established by MPLS TE. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_RESYNC_ASSERT ### Response: (Severity: 3), (Category: FABRIC), (Description: During the deferral window, fsdb_server didnt hear from a driver or rack due to some connection/transport issue. Restarting fsdb_server will try to recover it.), (Recommended Action: This clearly indicates an underlying transport issue. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_ATOM-6-LTRACE_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the ltrace module in the platform L2FIB ATOM component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-2-CRITICAL ### Response: (Severity: 2), (Category: OS), (Description: Critical conditions are present. Possible resource shortage or coding error.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-ROUTE_RECONCILIATION_FIB_EOD_RECEIVED ### Response: (Severity: 4), (Category: PLATFORM), (Description: System is booting in warm mode and is resynchronizing routes with the ASIC. FIB EOD is intermediate step in route reconciliation.), (Recommended Action: No recovery is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-1-RX_LINK_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Fabric arbiter detected RX Link error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-LTRACE_INIT ### Response: (Severity: 7), (Category: SYSDB), (Description: The ltrace buffer could not be initialised), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-4-FABRIC_BANDWIDTH_LOW_THRESHOLD ### Response: (Severity: 4), (Category: FABRIC), (Description: When the available fabric BW goes below the required BW that corresponds to the low threshold, then the front panel ports of the LC go down.), (Recommended Action: 1. Make sure you have enough FCs in your system. 2. Check the BW threshold. 3. Make sure your planes are UP and running) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-MAG_NOT_AUTHORIZED_FOR_PROXY_REG ### Response: (Severity: 3), (Category: IP), (Description: PBU is received from a MAG which is not configured as a peer on the LMA or dynamic MAG learning is not configured on the LMA.), (Recommended Action: Either configure the peer MAG on the LMA or enable dynamic MAG learning. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-FANTRAY_RPM_CLEAR ### Response: (Severity: 4), (Category: PLATFORM), (Description: All fans on indicated fan tray operating at the set RPM.), (Recommended Action: None required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_MIB-3-INIT_ERR ### Response: (Severity: 3), (Category: SNMP), (Description: First %s : Error Description Second %s : Return code string An error occurred while initializing ATM MIB support in snmpd process. If this occurred during process startup, then the process may be restarted. The error could be a part of one/more of the following: - database initialization - ifmib notify registration - sysdb binding process - registration for a trap - initialization of a trap OID string), (Recommended Action: If the problem re-occurs, collect required information and logs. If this is observed during startup, then corresponding process may be restarted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VI_REPL-3-REPLICATE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A failure occurred during the replication of an item of virtual interface configuration to one or more of the backup RPs.), (Recommended Action: The process will restart and attempt to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-STARTUP_FILE_DIR_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: Failed to open the startup configration file for the following reason: - CONFIG_FILE is set to a directory.), (Recommended Action: CONFIG_FILE should be set to a valid startup configuration file.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC_LIB-6-LTRACE_INIT_FAIL ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message that ltrace initialization has failed), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COMMON-0-RSP_HEADLESS_ACT_RSP_HB_REQ_FAILURE ### Response: (Severity: 0), (Category: PLATFORM), (Description: This RSP has timed out waiting for Heartbeat requests from the active RSP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_SERVICE_EA-3-ERR_CLIENT ### Response: (Severity: 3), (Category: OS), (Description: service-application IPSec is unsupported on this variant of LC. If this LC forwards traffic to a service-application IPSec enabled interface then traffic will get forwarded in cleartext or packets may get dropped.), (Recommended Action: Replace the LC if you want it to support service traffic. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AVPAIR-6-ADD_FAIL ### Response: (Severity: 6), (Category: OS), (Description: avpair_add failed while unpacking the Posix message into avlist), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MLIB-3-DELETE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error. Deleting an entry from ingress or egress failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_OUT_MEM_CORR_ECC_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast output memory correctable ECC error on link 2), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-4-CONFIG_CONFLICT ### Response: (Severity: 4), (Category: L2), (Description: A configuration conflict has been detected: Interface %s already used ' ' by MCLAG feature. ICCP-SM will not work until the conflict is resolved.), (Recommended Action: For MCLAG to work for this interface, one must delete relevant configurations for both ICCP-SM and MCLAG. Then re-configure ICCP-SM.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-4-LNS_CCDF_OVERFLOW_ERROR ### Response: (Severity: 4), (Category: FABRIC), (Description: Ingressq LNS control cell fifo overflow.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-LINK_BAD_THREAD_INUM ### Response: (Severity: 7), (Category: OS), (Description: This is a debug message that is not compiled into a customer version of the code.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-FATAL_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: NPUXBAR bridge has a fatal error.), (Recommended Action: Reboot the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-TSPI_OUTOF_FRAME ### Response: (Severity: 1), (Category: PLATFORM), (Description: TxSPI out of frame error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP-4-INITIALISATION_FAILURE ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the process. This resulted in the restart of the process.), (Recommended Action: The process will automatically exit and will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMS-7-PROTOCOL ### Response: (Severity: 7), (Category: SYSDB), (Description: There was a mismatch between the messaging protocol version used by the SysDB MC and the SysDB server.), (Recommended Action: Upgrade all nodes to have the same version of SysDB installed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HOSTNAME_SYNC-3-SYNC_ETC_HOSTS_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Failed to update /etc/hosts file with the new hostname), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_INTF-3-INIT_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A failure occurred during initialization with a necessary service for the process. The process is unable to run.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-6-CNET_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Cnet writing data into ethernet ok. %s- The data written into ethernet.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-4-RETRY_ALARM ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: It has been detected that the configuration or install operation sent to the Satellite could not be enacted for an extended period of time, even following retries.), (Recommended Action: Run 'show nv satellite error-retries satellite ' to display the configuration or operations that could not be enacted and the reasons why. should be in the range 100-65534 and is specified in the message. The user may need to correct the configuration or command used for the operation to address the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-1-LOSS_OF_SYNC_FIA00 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Loss of sync on interlaken interface on egress mux and fia 0), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-6-OPTICS_NOT_RX_PWR_DOM_CAPABLE ### Response: (Severity: 6), (Category: PLATFORM), (Description: Opticas is not DOM capable for RX power. So RX_OPD alarm will not be set for Rx Power < OPD threshold.), (Recommended Action: Try replacing with the DOM capable optics - show tech-support ethernet interface location <> - show controller <> phy - show controller <> internal) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_ASR9K_SCH_LIB-2-GET_NODEID_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message signifies that the DLL can not longer receive any event messages from the platform process in the router.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_SIM-4-BAD_NVRAM_MAP ### Response: (Severity: 4), (Category: MEDIA), (Description: Mapping of Nvram Failed), (Recommended Action: 'Check for 2MB size NVRAM') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-LSP_SWITCH ### Response: (Severity: 5), (Category: ROUTING), (Description: The specified interface has changed operational state.), (Recommended Action: None. This is a solicited message (by 'logging event lsp-status switch' \ interface configuration) and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-NOTIFY_LOCK_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: An expected database lock was not held. This could indicate a memory corruption problem.), (Recommended Action: Take a dump of the process and restart it. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDS_DB-3-RWLOCK_DESTROY ### Response: (Severity: 3), (Category: OS), (Description: Failed to destroy read write lock.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the spf-interval command in IS-IS? ### Response: The spf-interval command is used to configure the minimum interval between consecutive SPF calculations. By default, the SPF interval is 5 seconds. Increasing this interval reduces the CPU load on the router but increases the convergence time after a topology change. The trade-off between CPU utilization and convergence time should be considered. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_OC3_OC12-3-ERR_RESTART ### Response: (Severity: 3), (Category: L2), (Description: There is an error detected during SPA process restart. During the process restart, the software will do: checking the hardware config compatibility; re-creating SONET controller and POS interface; restoring configurations. Any failure in above will cause restart failed. The traffic may or may not be affected after restart failed, but the further operation on SPA, e.g. changing configuration, may not be carried out properly. %s - error message indicating location and the reason of the error), (Recommended Action: The system will try to restart the process again for a few times, If the issue persists, reload the SPA with the command: hw-module subslot 0/x/x reload If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPI-3-ATTR_NOTIFY_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The Ethernet Packet Infrastructure (EPI) library was unable to notify a client of a change to some interface attributes because it was unable to allocate memory. This may result in the client of the EPI library attempting to send packets with incorrect tag or encapsulation information.), (Recommended Action: This message will be seen as a result of a configuration change if the system is low on memory. Attempt to free up some memory and reapply the configuration change that caused this message to be displayed. If the problem persists, try restarting the process using this library. If this does not help, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-3-ENET_INIT_DEVICE_DATA_ERR ### Response: (Severity: 3), (Category: OS), (Description: This is during the device Initialization. Data structure intialization has failed %s- Error description), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-NODEID_FAIL ### Response: (Severity: 3), (Category: SYSDB), (Description: Unable to perform SysDB health check since the process is not able to retrieve its node id.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY_DB-3-KERNEL_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: A system library call failed unexpectedly. This failure can occur due to any of the following failures. 1. Failure while obtaining DB read lock 2. Failure while obtaining DB write lock 3. Failure while releasing DB read/write lock 4. Failure while obtaining TTY lock 5. Failure while releasing TTY lock), (Recommended Action: Please get the information specified under the component required_info and call your Cisco technical support representative and provide the gathered information with this error message text. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-CHKSUM_ERR_1_FIA_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Checksum error - 1 from FIA on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-7-DEBUG_STAT ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-2-MPLS_BGP_LU_KEY_ERROR ### Response: (Severity: 2), (Category: ROUTING), (Description: In bgplu label create, key conflict occurred), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-FIND_VIRT_INST_ENTRY ### Response: (Severity: 3), (Category: OS), (Description: The virtual service with the ID named could not be located in the Virt-manager DB.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_FADB-3-SHM_OPEN_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB FADB encountered an error while attempting to open the FADB shared memory), (Recommended Action: Search the event logs for events/errors related to the failure reason. Shared Memory Management and disk access is part of overall system. If there are failures here then other processes may also exhibit similar problems. Collect all the event logs (show logging) output of the following command. 'admin show process fsdb_fadb location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSU-4-PM_ASLEEP ### Response: (Severity: 4), (Category: LIBRARY), (Description: The power module is asleep.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SEQ_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected sequence error on some bus, this could be software error), (Recommended Action: Please try to correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-4-ERR_THREAD_COND_SIGNAL ### Response: (Severity: 4), (Category: FABRIC), (Description: FSDB encountered an error while attempting to signal a thread conditionally. The operation related to the resource will be affected and the process will continue to run normally.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-4-LTRACE_INIT_FAIL ### Response: (Severity: 4), (Category: IP), (Description: There was a failure during an ltrace_init api call which resulted in the failure as indicated in the message text.), (Recommended Action: None of the traces can be saved in this case. If tracing is very much important to be collected then restarting of ipv6_io may fix this issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_MQ_PKT_LEN_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue packet length error on XAUI 0 MQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FLOWTRAP-3-DISABLED_DANGLING_BAD_ACTORS ### Response: (Severity: 3), (Category: OS), (Description: The LPTS Excessive Punt Flow Trap (EPFT) feature was disabled by configuration, but not all existing interfaces which are using more hardware resource (i.e Bad Actors) on this node were cleared. This may affect the creation of new sessions or sub-interfaces. When a flow through any interface is trapped, it is tagged as a Bad Actor and will be added to 'penalty box', this box will restrict the traffic through that interface by applying penalty policing.), (Recommended Action: Try clearing Bad Actors manually, or reloading the line card. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-EXIT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The specified process failed to notify the system manager that it was exiting. In very rare cases, this could result in the process not being restarted when it ought to be.), (Recommended Action: If the process in not running and it ought to be (ie, there is CFM configuration remaining), then remove all CFM configuration, commit this change, then re-apply the configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-SM_DRIVER_CONNECT_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: An error was encountered while the specified process was initializing. The error message contains details about the source of the error. Frequency synchronization on this line card is disabled.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-MAINT_IMG_LOAD_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: TBD.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_APS-6-SWITCH_INFO ### Response: (Severity: 6), (Category: L2), (Description: Debug messages for APS.), (Recommended Action: No Action requirements.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATSD-3-SHMEM_LOCK ### Response: (Severity: 3), (Category: MGBL), (Description: A failure occurred when attempting to acquire a shared memory lock), (Recommended Action: This message probably indicates an error elsewhere in the system as some other process must be holding the lock. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-0-GRACEFUL_CARD_RESET_TIMED_OUT ### Response: (Severity: 0), (Category: PLATFORM), (Description: The Grace Card Shutdown/Reset request with the sysmgr timed out. Attempts to perform a non-grace node reboot instead.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_25 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-INVALIDDETAILS ### Response: (Severity: 3), (Category: MGBL), (Description: 'The offset to the token details structure is bogus'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-2-SR_CFG_CHANGED ### Response: (Severity: 2), (Category: ROUTING), (Description: BGP will be notified of any change in the SRLB/SRGB range config. When BGP programs the SR labels into LSD, it derives those labels based on SRLB range start and indivisual SR index. All these SR labels have to recalculated based on new range and reprogrammed into LSD. In case the SRLB/SRGB range is changed, Please restart BGP to re-program the labels.), (Recommended Action: Restart BGP process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_FPGA-1-ERR_HW_ERR_DISABLE_INTERRUPT ### Response: (Severity: 1), (Category: L2), (Description: A hardware error reached threshold on the Datapath FPGA. Software will take action as described in the error message to try to recover from the error. Take the recommended user action as it is described in the error message. Device: %s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Software action: %s - the action that software will take to try to recover from the error. Recommended user action: %s - description of the recommended user action.), (Recommended Action: If the message recurs, diagnostics should be executed on the PLIM and MSC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COPP_SAMPLER-7-INIT_ERR ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: The CoPP Sampler Plugin encountered a fatal error during initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: c2c_iif-3-ERR_HW_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Hardware initialization failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-7-OBJECT_REBUILD_FAIL ### Response: (Severity: 7), (Category: ROUTING), (Description: The system was atempting to rebuild an object and it failed.), (Recommended Action: Look for out of resource conditions. The policy_repository will exit and restart. Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CSCMIB-4-SYSDB_ACCESS ### Response: (Severity: 4), (Category: SNMP), (Description: The MIB was unable to read to or write from the system database, so will be unable to provide some requested MIB data.), (Recommended Action: The communications infrastructure may not be up yet. The operation will automatically be retried and recovered. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCENET-3-IO_PRIV ### Response: (Severity: 3), (Category: PLATFORM), (Description: The ethernet driver is unable to get the necessary privileges to perform an operation vital to its functionality.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of IS-IS route summarization and where is it configured? ### Response: Route summarization reduces the size of the link-state database and hides instabilities. It is configured on L1/L2 border routers to summarize L1 routes before advertising them into L2. The command is ""summary-address"" in IOS and ""summary-prefix"" in IOS-XR. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-2-ERR_NO_MEMORY ### Response: (Severity: 2), (Category: SECURITY), (Description: A memory allocation failure has occurred from which the process cannot automatically recover.), (Recommended Action: 'The process must be restarted to ensure correct operation. If memory is repeatedly exhausted upgrade to a larger memory configuration.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-6-CONF_CONNECT ### Response: (Severity: 6), (Category: MGMT), (Description: This comes when connection to configuration database returns error (this could be temporary as configuration database is down), retrying login would gives success once configuration database comes up), (Recommended Action: Wait for configuration database to come up, and retrying login, check configuration database is running or not, using show confd_helper location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_FGID_ACCESS ### Response: (Severity: 3), (Category: FABRIC), (Description: One or more ASICs for the stage on the fabric card are being reset. Hence this multicast FGID access operation for the specified stage is aborted. This may be seen on any SM node going down, during asic reset cleanup process.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSU-4-PM_AWAKE ### Response: (Severity: 4), (Category: LIBRARY), (Description: The power module is awake.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-XFP_NPOWER ### Response: (Severity: 4), (Category: L2), (Description: The XFP device lost its power OK state causing the link to flap. A reset of the XFP device corrected the issue.), (Recommended Action: None. Software corrected the issue by power cycling the XFP device.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV6-3-INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: Errors occuring during initialisation of IPV6 FIB platform.), (Recommended Action: Please collect the required logs. Also notice if the error message is transient or persistent. If errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-I2C_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: I2C Failure/Success while accessing device), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_GROUP_CREATE ### Response: (Severity: 4), (Category: L2), (Description: Creation of the group used to communicate between Bundle Manager processes failed. This resulted in the restart of the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show gsp groups command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show gsp groups output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RLOGIND-3-ERR_SYSDB ### Response: (Severity: 3), (Category: IP), (Description: The Telnet Server has encountered an error using the SysDB Library.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFI_MA-3-INIT_ERR ### Response: (Severity: 3), (Category: L3), (Description: An unrecoverable error has happened while initializing SFI MA process. sfi_ma will be restarted automatically. SFI interfaces may get created later.), (Recommended Action: The process should recover automatically. It is suggested to collect 'show tech-support infra sfi' and to call Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlma-4-INIT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The VLAN MA process failed to initialize. Previous messages may give the reason. The process will automatically restart and retry. Until it succeeds, VLAN functionality may not work on the affected node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTT0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-6-PKG ### Response: (Severity: 6), (Category: MGBL), (Description: Some configuration was removed for this software activation /deactivation operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_IPV6_EA-3-CRITICAL ### Response: (Severity: 3), (Category: PLATFORM), (Description: SSE IP-EA, Critical error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-TX_ALARM_TMF ### Response: (Severity: 3), (Category: PLATFORM), (Description: Condition raised possibly due to incorrect internal BITS transmitter configuration.), (Recommended Action: Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XFP-3-LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected an XFP Tx power less than or equal to the low Tx power warning threshold. The XFP is the pluggable optics on the line cards. The Tx power threshold values are read from the XFP.), (Recommended Action: Verify that the device is properly inserted. Replace the XFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNVGEN-3-ERR_SYSDB_ITEM_GET ### Response: (Severity: 3), (Category: MGBL), (Description: 'Unable to get the item from sysdb. The error is displyed in the error message.'), (Recommended Action: Collect the following logs and contact your technical support representative for assistance. a) Console logs b) show tech-support parser c) show tech-support sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-4-MBI_COPY_FAIL ### Response: (Severity: 4), (Category: INSTALL), (Description: DRP MBI copying failed. This card will not be able to boot.), (Recommended Action: Cleanup will be automatically attempted. No user action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_STU ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from STU.), (Recommended Action: Clear the SSM-STU condition.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHOWTECH-0-EMERG ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-6-IOFPGA_EXT_ALARM ### Response: (Severity: 6), (Category: DRIVER), (Description: Card manager has received an interrupt from IOFPGA board and this interrupt is suggesting to close the chassis ext alarm), (Recommended Action: This is an indication about the chassis ext alarm) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-RAW_PART_ATTR_LOW_MEM ### Response: (Severity: 3), (Category: MEDIA), (Description: Could not get enough memory while trying to initialize nvram.), (Recommended Action: 'Router running low in memory. Reboot if possible.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_FPD-3-ACCESS_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that a failure has occured in accessing the FPD and may not be able to either program new firmware or get device information), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFMMIB-3-NO_TIMER ### Response: (Severity: 3), (Category: L2), (Description: An error was encountered in the initialisation of the DOT1AG and MEF SOAM PM MIBs. The error message contains details about the source of the error.), (Recommended Action: Tables in the DOT1AG/MEF SOAM PM MIB will not be accessible. Restart the mibd_interface process in an attempt to clear the error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_0_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_TX_FIFO_OFLOW_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI interface to NPU-1 reported tx fifo overflow on bridge instance - 3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOMAIN_SERVICES-3-CREATE_CHANNEL ### Response: (Severity: 3), (Category: IP), (Description: The domain_services process failed to create a channel so that other processes can send event messages to it. The error is normally seen when initializing DNS process), (Recommended Action: The error should go away with process restart domain_services loc all. If the error persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-2-MB_POWERUP_CHECK_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: The voltage validation and power status check for the card failed. This might be a power issue to the card or a faulty card.), (Recommended Action: Try reloading the card or physical OIR, verify power to chassis and the card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOMAIN_SERVICES-7-BSD_DEBUG_MSG ### Response: (Severity: 7), (Category: IP), (Description: Displays the debug msgs as they happen), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-4-WARNING_MEM_DIGEST ### Response: (Severity: 4), (Category: SECURITY), (Description: SAM found MEM digest compare not successful, discard the memory packages.), (Recommended Action: 'Users MUST re-install all the memory packages (SMU/PIE). If this message recurs, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CERR_LIB-7-SHM_OPEN_ERR ### Response: (Severity: 7), (Category: OS), (Description: shm_open failed to open the shared memory, that is already created. errno was not set.), (Recommended Action: It is notified that shm_open failed to open the shared memory, and errno was set to EACCESS.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-FSDB_RESPONSE_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: Npu_driver response is not encoded becuase of bufsize is too small.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-ROUTES_DROPPED ### Response: (Severity: 3), (Category: ROUTING), (Description: A synchronous route operation request received when server initialized in asynchronous mode or vice versa; or when server is not ready.), (Recommended Action: Controller and/or agent must ensure that route operation requests are sent only in the mode specified by the client initialization message and server is ready. If message is still seen after meeting these conditions, contact Cisco for support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-RED_MGMT ### Response: (Severity: 5), (Category: L2), (Description: There has been a misconfiguration resulting in the problem described being hit in the redundancy handling for the bundle.), (Recommended Action: Correct the misconfiguration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-MISMATCH ### Response: (Severity: 7), (Category: MGBL), (Description: An unmatched ''' or '{' character was found part way through a token in a command string.), (Recommended Action: Re-enter the command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_11_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSMGR-3-INIT_FAILURE ### Response: (Severity: 3), (Category: INSTALL), (Description: A failure occurred initializing a necessary module of the QS Manager process. The process is unable to run and will respawn to retry. The system may be in an unstable state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAN-3-RESET_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The reset of the switch failed for some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Collect console log and the following information. - show control mlan switch-status - show control mlan switch-atu - show control mlan port-status - show control mlan port-counters - sh process ether_ctrl_mgmt) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR provide process-level isolation and memory protection? ### Response: Cisco IOS XR uses a microkernel architecture where most processes run in their own protected memory space. Each process has its own virtual address space that is not accessible by other processes. This prevents a memory corruption or crash in one process from impacting other processes or the kernel. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_0_ERR1_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 0 ran into error-1 on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-3-CONFIG_INVALID_NODEID ### Response: (Severity: 3), (Category: L2), (Description: One or both of the PoAs in the redundancy group have an invalid node-id.), (Recommended Action: Reconfigure the peer ICCP-SM multi-homing node-id to a valid value. Note that both PoAs must have a unique node-id.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_HFR-7-ERR_EVENT_CONN_EVM_HANDLER ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to register event handler for the posix message queue. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR-3-RX_BUFF_CRITICAL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ethernet server is performing a periodic self test to ensure that sufficient receive buffers are available at any given time. This error msg means that the test failed and available receive buffers has gone below 64. Eth server will correct the condition by restarting itself and operator needs to do nothing.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers backplane ethernet trace location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers backplane ethernet trace location output, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-PRIMARY_SERVER_EVENT_CONN_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNL_GRE_EA_PD-4-UNSUPPORTED_CONFIG ### Response: (Severity: 4), (Category: PLATFORM), (Description: GRE Tunnel is not supported on SIP700 linecards in ASR9K. If the SIP700 exists in the chassis where GRE Tunnel is configured, ASR9K will emit this warning message and GRE Tunnel interface is not created in SIP700 hardware. The GRE Tunnel adjacency will be programmed to drop on the SIP700 linecard. That means any prefixes resolving over the GRE Tunnel will point to drop adjacency on the SIP700. If SIP700 receives GRE encapsulated packets, those will be dropped as well.), (Recommended Action: Ensure that the network topology is such that GRE tunnel packets never ingress or egress through the SIP700 linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR-3-FAILED_CARD_TYPE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to get card type from shelf manager.), (Recommended Action: 'Please run the command again') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEPKI-3-ERR_TPINFO ### Response: (Severity: 3), (Category: SECURITY), (Description: Crypto error message for failure to obtain trust point info for a given label), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-CPU_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: CPU complex on the indicated card is reporting an error condition.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-APPLY_ERR ### Response: (Severity: 3), (Category: SYSDB), (Description: This message indicates applying configuration failed. As part of CLI configuration 'commit', use CLI 'show configuration failed' to view this error and failed configuration.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-3-DIE_OVERTEMP_SHUTDOWN_COUNT ### Response: (Severity: 3), (Category: PLATFORM), (Description: LC or port shutdown is schedulded if the temperature value stays above the critical thresold for 24 hrs or more), (Recommended Action: Verify the failure, use show env to help. If the failure does not alleviate, LC or port will shutdown. Call your technical support representative for repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: T1E1-4-LOOPSTATUS ### Response: (Severity: 4), (Category: L2), (Description: A configurable controller loopback status.), (Recommended Action: No action reqiured. Msg displays loop status) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-FALLBACK_SESSION_START ### Response: (Severity: 5), (Category: L2), (Description: After all config dependencies are resolved MKA started fallback session on interfaces with fallback configuration), (Recommended Action: No action required (normal operation).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-MEM_MAP_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: The memmory map operation mentioned in the message failed due to the reason mentioned in the message. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-LWM_FAILURE ### Response: (Severity: 7), (Category: HA), (Description: A call to a LightWeight Messaging function failed. This may be due to a server being unavailable at the time of the call.), (Recommended Action: Collect system log information if it appears that this message is linked with failures in functionality. Otherwise, the message can be ignored.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-4-COLD_RESET_FAILED ### Response: (Severity: 4), (Category: L2), (Description: This is an error message in the NPU Driver to indicate that it failed to perform cold reset of specified NPU instance due to the specified reason.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT-3-PLL_NOT_LOCKED ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLL inside the FPGA device is not locked.), (Recommended Action: The software should be able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TOPMGR-3-CHILD_NOTFOUND ### Response: (Severity: 3), (Category: PLATFORM), (Description: Although a reference to a child interface is found in the parent interface, the child interface cannot be found via the search routine. Either the child interface failed to be added in the first place or the reference was not cleared when the child was deleted.), (Recommended Action: Examine the trace buffers and pay attention to all the insert and delete operations.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: uea-1-RESTART_NOT_SUPPORTED_SUPPL ### Response: (Severity: 1), (Category: PLATFORM), (Description: This is an error message associated with RESTART_NOT_SUPPORTED See RESTART_NOT_SUPPORTED for explanation), (Recommended Action: See RESTART_NOT_SUPPORTED for explanation) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_SW-3-CLEAR_MAPPING_FAILED ### Response: (Severity: 3), (Category: IP), (Description: --), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the Cisco IOS XR System Manager (sysmgr)? ### Response: The System Manager (sysmgr) is responsible for overall system initialization, monitoring, and restart functions. It is the first process started on each node. It spawns, monitors, and can restart other processes based on their criticality and restart policies. It also coordinates role transitions between active and standby RPs. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-4-LWM_UNEXPECTED_ERROR ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: This is a temporary ios_msg to identify when an unexpected error is returned when communicating with the IM server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: G8032-6-STATE_CHANGED ### Response: (Severity: 6), (Category: L2), (Description: Informational message to notify the state transitions for a ring instance.), (Recommended Action: None. This is informational message to indicate an event may have triggered some ring protection action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-TEJAS_FPGA_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in read/write access of a tejas fpga device register. This error could result in communication loss between MSC and Services PLIM.), (Recommended Action: Do warm reload of the Services PLIM MSC. If the issue persists do a cold reboot of the same. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-RDDR_FIFO0_PAR_ERR ### Response: (Severity: 0), (Category: PLATFORM), (Description: RxDDR 1875 to 200 FIFO 0 parity error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFGHLP-6-CONFIG_SAVE_DELAY ### Response: (Severity: 6), (Category: MGBL), (Description: An attempt to save the node configuration has taken longer than expected. This may be due to a high volume of activity within the configuration management system.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-4-ERR_MEM ### Response: (Severity: 4), (Category: SERVICES), (Description: CGN modules are failed to allocate memory due to low memory conditions in the System.), (Recommended Action: Increase System Memory or stop some applications which are not required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-3-MEM_ALLOC_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Packet server failed to allocate more memory.), (Recommended Action: It may be necessary to free some memory by exiting a program. If this message recurs, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-4-SRCINTF_NOTUP ### Response: (Severity: 4), (Category: SECURITY), (Description: The interface specified as source interface is not UP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-ACL_EXCEEDED_MAX_INT_TCAM ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: ACL exceeds maximum number of entries for internal TCAM.), (Recommended Action: Reduce the number of total physical ACEs or prefixes in object groups and/or range keywords in the ACL.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP-4-INVALID_L2VPN_STATE ### Response: (Severity: 4), (Category: L2), (Description: When acknowledging a state update, the L2VPN infrastructure sent an invalid value.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-2-CRIT_EXIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: An critical error occurred in NP Driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-REP_COM_REMOVE_ABORTED ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that the install remove inactive all triggered as part of replace commit operation has aborted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NQC-6-ISOLATION_NOTENABLED ### Response: (Severity: 6), (Category: OS), (Description: RP Isolation is not enabled either on this platform, on this card type or it is not configured. A normal reboot will be done.), (Recommended Action: No action is required on this. This is only an informational message and is expected to show if the feature is not supported on the platform or has not been configured by the user.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between installing a package using the install add command versus the install activate command? ### Response: The 'install add' command copies the package to the router's storage but does not make it active. The 'install activate' command is used to make the package active on the router. Packages can be added and activated in a single step using 'install add' followed by 'install activate' in a single command line. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-DECODE_TUPLE ### Response: (Severity: 3), (Category: MGBL), (Description: Nvgen server failed to convert sysdb tuple into readable config command. This may result in failure to show some of the configuration or in in writing configurations to internal config backup.), (Recommended Action: Collect the following details show version, show logging, 'show nvgen trace ascii | include DECODE TUPLE' output, show nvgen trace output, show runnning output, show config history and show tech-support parser. Contact TAC representative with this information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ACL_DAEMON-7-INIT ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN_EA-3-MEM_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A low-memory condition was detected in the Platform SPAN module.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTR4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-VRF_ALREADY_ASSOCIATED ### Response: (Severity: 3), (Category: L2), (Description: VRF is already associated with logical switch, first remove this association.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-5-ROUTES_REPLAY_OK ### Response: (Severity: 5), (Category: ROUTING), (Description: Serivce layer successfully replayed routes to Routing Information Base from a previously errored state.), (Recommended Action: No action needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-CT2_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a parity error), (Recommended Action: Please correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_1_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_7_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-6-PORT_USAGE_BELOW_THRESH ### Response: (Severity: 6), (Category: PLATFORM), (Description: Ports consumed have fallen below 90% threshold for this particular IP. Details will be given in the meesage displayed), (Recommended Action: None. System should be in stable state and all Translation should go through fine) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-MEMORY_LIMIT_WARN ### Response: (Severity: 3), (Category: OS), (Description: The virtual service machine definition file is requesting more memory for the specified profile, than the system has available for virtual services.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-CRE_STATUS ### Response: (Severity: 4), (Category: DRIVER), (Description: When FC cards boot up and it has CRE fpga during bootup we check if cre is up , if not up we try a recovery of it because any pluggables wouldnt work without cre being up.If it doesnt recover we log a syslog that CRE is not up.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WAN_LIB_IFDB-3-NOMEM ### Response: (Severity: 3), (Category: L2), (Description: The system is low on memory and not enough was available to complete the request), (Recommended Action: Check the box for processes with excessive memory. If the problem persists collect the required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHNLZD_EFCM-3-ERROR_CFG_BUFF_OPEN_MEMORY ### Response: (Severity: 3), (Category: L2), (Description: An error has occurred in the Extended Flow Control Manager. EFCM was unable to open shared memory for debug.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-0-NO_RSP_ACT_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: LC CPU controller driver detected no active RSP in the system.), (Recommended Action: If there are no RSPs present or if both RSPs are undergoing a reload, then this is an expected message. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMITH-3-CONN_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This indicates a channel setup or communication failure within the process. This will lead to incomplete initialization of the driver impacting driver functionality.), (Recommended Action: If it is a message send failure then the software will retry. If it is a channel setup failure then restart the client process to check if the channel setup goes through fine 'process restart loc <>'. Contact support team if the issue persists.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERG-5-ACTIVATION_COMPLETE ### Response: (Severity: 5), (Category: INFRA), (Description: The activation of sessions on the SLAVE has been completed. This is either in response to CLI command or a dynamic failure trigger on a SLAVE which has been configured as a warm-standby.), (Recommended Action: None required if there has been any network event or administrative action that caused this activation of sessions. Session status may be checked on the slave router to verify consistency, if desired.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-REPLACE_COMMIT_PRECHECK_STARTED ### Response: (Severity: 3), (Category: INSTALL), (Description: Specified message provides info that install commit as part of the replace operation couldnt be started as failures are seen during the precheck phase.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_0_PKT_MINLEN_ERR_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet minimum length error on NPU-0 interface on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GT_I2C-3-ONBOARD ### Response: (Severity: 3), (Category: PLATFORM), (Description: As shown in the message.), (Recommended Action: SC Switchover can be performed to recover. To switchover, issue 'redundancy switchover location '.If the error occurs even after redundacy switchover, Please collect required_info log/trace and contact Cisco technical support representative with required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_PAK ### Response: (Severity: 4), (Category: L2), (Description: The connection to packet manager was errored and the attempt to recover failed. Restarting the process should resolve the problem.), (Recommended Action: Restart the ppp_ma process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-DDR_BUS_BIT_STUCK_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: DDR bus databit stuck on bridge instance-3.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROL_DRIVER_RSP4-3-POWER_OK_NOT_RECEIVED ### Response: (Severity: 3), (Category: DRIVER), (Description: Power OK not recived 1. After Power Enable 2. After Power reset), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NCS4K_4H_OPW_QC2-4-LASER_IS_ON ### Response: (Severity: 4), (Category: PLATFORM), (Description: Some devices (DENALI, CFP2) cannot be upgraded in field if the CFP2 laser is ON. Download of these binaries is not reliable with laser ON. Download of these binaries with laser ON will disrupt traffic and possibly leave the device in an inconsistent, unrecoverable state. Donwload is prevented with laser ON on CFP2 ports.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-6-INFO_CID_SES_LIMIT_NOT_REACHED ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions on a particular Circuit ID is no longer exceeding the configured maximum.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ND-3-INIT ### Response: (Severity: 3), (Category: L2), (Description: There was a software error during process startup.), (Recommended Action: The process will restart and try to recover. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise, check whether the error code contained in the message indicates that there was a failure to allocate the necessary memory and take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If resource allocation was not the problem and it hasn't been fixed by a subsequent restart, then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the process does not restart automatically, restart it manually. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: deflate-3-output_dir_error ### Response: (Severity: 3), (Category: OS), (Description: The compression output directory cannot not be accessed with the reaaon given by the error string.), (Recommended Action: Please check the accessibility of the output diretory if it is from a user entered CLI. Please capture show log and error messages if the error is not due to user entered CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-EVQ_CRE_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: An unexpected error occured whilst creating an event queue during process initialization. This may be a system resource problem. As a result IS-IS will be unable to operate correctly.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_OPTICAL_PWR_LOSS ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SM-4-NONFATAL_ERROR ### Response: (Severity: 4), (Category: INSTALL), (Description: A non-fatal error has been encountered. The system will continue to operate, but this error should be brought to the attention of TAC.), (Recommended Action: This is a non-fatal error and has no impact on functionality of the system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_LIB-4-SDIR_INVALID ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The Service Director process/library sent an invalid message to the SVII Adjacency Manager. This indicates a problem with the Service Director. It is likely that packets will not be correctly forwarded to some Service Virtual Interfaces.), (Recommended Action: It may help to restart the SVII Adjacency Manager and/or the Service Director processes. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MACLEARN-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to setup event manager.), (Recommended Action: No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-6-PROTOCOL_START_STOP ### Response: (Severity: 6), (Category: L2), (Description: The operational status of the E-LMI protocol on the interface has changed. If undesired, the notification of protocol events can be turned off by configuring 'log events disable' on the interface.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-THREAD_PRIORITY ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred when trying to set the priority of the Protect thread. This will not cause any loss of functionality, e.g. notifications of bundle interface failure will still be delivered to trigger fast reroute. However, such notifications may be delivered with higher latency.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR-3-EA_ALLOC ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates that the pbr_ea process has failed to allocate memory. This may be due to low memory conditions on this particular node, or pbr_ea may be using more memory than it is allowed.), (Recommended Action: Reduce system scale. If the problem persists even with reduced system scale, please contact Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BANNER-7-SYSDB_REGISTRATION_FAILURE ### Response: (Severity: 7), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_UV-3-EVENT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred in the main ospfv3_uv event loop.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_BOARD_ALERT ### Response: (Severity: 3), (Category: FABRIC), (Description: Power controllers on the fabric card are raising the alerts indicating that either the voltages or temperature on the card is at its tolerance limits.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE_SWITCH-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error has occurred on the switch port. The message has the port identification, the error register, and and the error description.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-3-DEBUG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Error encountered in debug module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RLOGIND-4-ERR_SOCKET ### Response: (Severity: 4), (Category: IP), (Description: Internal warnings related to socket operations.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-4-SEQUENTIAL_NAT_PRESENT ### Response: (Severity: 4), (Category: SERVICES), (Description: SEQUENTIAL NAT PRESENT CALCULATION IS NEEDED FOR PRIVATE POOL CONFIGS PER VRF .), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-ERR_TTY_IFH_PRESENT ### Response: (Severity: 3), (Category: SECURITY), (Description: In the AV pair message recieved from the radiusd clients should have either ttyname or interface handle, not both.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-SOCKET_RESMGR_ATTACH ### Response: (Severity: 3), (Category: ROUTING), (Description: The clns process failed to advertise itself to the system as a resource manager.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-CLOSE_DEVICE ### Response: (Severity: 3), (Category: MGBL), (Description: Failed to close a file descriptor inheritited from the spawning process so that the appropriate device files can be reopened for exec to read/write.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-3-HA_PMW_CONN_REG_RETRIES ### Response: (Severity: 3), (Category: L2), (Description: STP IO has failed to connect and register with the Process Manager Infrastructure after multiple retries. Reconnection and registration will continue to be retried at a slow rate. If STP IO fails to connect with Process Manager, it will not be notified of the ISSU switchover, and may result in unexpected behaviour.), (Recommended Action: Check the status of the Process Manager process (processmgr) for any obvious errors. Unless STP IO (stp_io) can reconnect to Process Manager, it will not be notified of the ISSU switchover, and so the ISSU operation will likely need to be aborted and retried. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-6-EVENT_CONN_INIT_FAILED ### Response: (Severity: 6), (Category: SECURITY), (Description: An internal software error occured), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-SYS_MGR ### Response: (Severity: 3), (Category: L2), (Description: Connection to sysmgr_proc_ready() has failed.Sysmgr process ready API failed.), (Recommended Action: No action is required. Process will be restarted.If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_LIB-4-FAIL_LWM_REPLY_TOO_BIG ### Response: (Severity: 4), (Category: INSTALL), (Description: Install director gave an incorrect message reply size to a client), (Recommended Action: Client will automatically resend LWM message with bigger buffer. No user action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_LMI-3-SENDTO ### Response: (Severity: 3), (Category: L2), (Description: The socket call sendto returned an error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-CPU_PKT_TOO_LONG ### Response: (Severity: 2), (Category: PLATFORM), (Description: IBS from CPP packet too long error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-3-WRONG_IMAGE ### Response: (Severity: 3), (Category: INSTALL), (Description: insthelper detected that a wrong image has been booted.), (Recommended Action: Please boot the node with the correct MBI image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an L2VPN EVPN Ethernet segment? ### Response: To configure an L2VPN EVPN Ethernet segment, use the 'ethernet-segment' command within the EVPN instance configuration. l2vpn evpn ethernet-segment identifier type 0 0000.0000.0001 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: d1qnetio-4-CHAIN_UNBUILDER_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The software forwarding support for IEEE802.1Q VLANs was unable to clean up an interface. Forwarding should not be affected.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_CLNS_MAC_ADDR_NOTIFY ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to notify the CLNS protocol stack of MAC address changes to the specified interface. It requires a restart of process for recovery.), (Recommended Action: Restart the IS-IS process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_RP-3-XID_COUNT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Incoming bridge XID count is more than allocated XID count.This may occur to due to a programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONCERTO-7-ERR_LWM_EVENT_BLOCK ### Response: (Severity: 7), (Category: PLATFORM), (Description: CONCERTO Event Manager event block error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-SDR_RELOAD_INFO ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that the SDR will be reloaded as part of the specified install operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_EA-3-EVENT ### Response: (Severity: 3), (Category: SERVICES), (Description: An error (other than EINTR) occured in the event loop. The process must exit.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_9_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-PTP_CLK_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: IM related ptp failures), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP_VRF-3-RD_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: RD information for the VRF is not present. This can happen either if the RD configuration of the VRF is missing (or) because of an issue in BPM process publishing the RD information to Speaker.), (Recommended Action: If the RD configuration is missing for the VRF, please add the necessary RD configuration and that should take care of fixing the problem. Sometimes we might see minor delay in BPM publishing the RD to speaker, in such cases no functional impact will be seen and things will recover as soon as BPM publishes the RD to BGP speaker. No further action is required for this transient case. For all other scenarios, please collect the required information mentioned below and if recovery is desired, please restart BPM process or remove and reapply the specific VRF configuration. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ERR_THREAD_MUTEX_LOCK ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to lock a mutex failed. The error is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_OBJECT ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process failed unexpectedly to update RIB after an object state up event.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-2-XCVR_CODE ### Response: (Severity: 2), (Category: L2), (Description: The xcvr code is displayed for both supported and unsupported sfp/xfp types for the following actions - OIR of SFP/XFP - Soft and Hard OIR of SPA/LC - unshut of SPA - Enabling power for LC), (Recommended Action: No actions are required as this is just an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-EDM_DATALIST_ADD_FAILED ### Response: (Severity: 3), (Category: OS), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The attempt to add an item to an external data manager datalist has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-SBE_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: A single bit error was detected in CRAM/RAM of the IM in given slot. If it is in a critical region, IM will be soft reloaded else the error bit will be auto-corrected.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ERR_MEM_ALLOC_2 ### Response: (Severity: 3), (Category: MGBL), (Description: 'The system has run out of memory'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SATORI-4-WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: Satori RP Kensho-JF CPU Subsystem DLL warning message. No system functional impact.), (Recommended Action: Nothing. Reporting normal progress of Satori RP Kensho-JF CPU Subsystem DLL.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDR-3-SDK_INIT_FAILED ### Response: (Severity: 3), (Category: DRIVER), (Description: CDR SDK init failed for that specified slot/phy_id'), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_HQ_SEQ_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue sequence error on XAUI 1 HQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to specify RSVP administrative groups in Cisco IOS XR? ### Response: To specify RSVP administrative groups, use the 'mpls traffic-eng admin-groups' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#mpls traffic-eng admin-groups Group1 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_THREAD_SET_SPECIFIC ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed to associate the specified per-thread resource with the thread. This may be due to a low memory condition but is most likely to be an internal software programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ALLOCATOR-7-NULL ### Response: (Severity: 7), (Category: OS), (Description: A client passed a NULL value into an allocator API, or an internal error caused a NULL value to be unexpectedly passed through to an internal API.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISLM-4-ACCOUNTING_HIGH_USAGE ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This syslog is printed when high usgae found in service accounting .), (Recommended Action: Collect Show tech and generated running core files.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAA-4-WHITESPACE_TRUNCATED_IN_SERVER_KEY ### Response: (Severity: 4), (Category: SECURITY), (Description: Whitespace is not allowed at the end of a server key.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR-3-UNKNOWN_FORUS_PAK ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ethernet driver received an unknown for us packet.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers backplane ethernet trace location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers backplane ethernet trace location output, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISLM-4-ACCT_STOP_REC_RPL_INIT_FAILED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This syslog is printed when acct stop record feature replication failed. File will not be replicated on standby.), (Recommended Action: Collect show tech subscriber.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-5-AUTH_COMPUTE_FAILED ### Response: (Severity: 5), (Category: ROUTING), (Description: The process encountered an error when computing the authentication digest. This may be due to misconfiguration on the local or remote system. It is possible that no currently valid keys are available.), (Recommended Action: Check the password and authentication configurations on the local system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_MPLS_EA-3-ERR_INFO_TWO_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in MPLS EA. Typically, this is an error where the software fails to initialize or programming of forwarding feature fails. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef mpls trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-4-BER_SF_ALARM ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message provide information that Signal Fail BER (Bit Error Rate) alarm is set or cleared on a specific port based on the BER configuation. port: on which alarm is set/cleared status: set/cleared), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - sh running interface <> - sh controller all - show tech-support ethernet interface location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-4-WARNING_RACK_NUM ### Response: (Severity: 4), (Category: PLATFORM), (Description: ROMMON RACK_NUM variable setting is different from the node_id rack field setting.), (Recommended Action: Set ROMMON RACK_NUM to proper rack number per chassis rack field) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-3-ERR_STR ### Response: (Severity: 3), (Category: L2), (Description: A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code and a string interpretation of the error code. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef trace location <> show cef platform trace common all location <> show cef platform trace ipv4 all location <> show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_FETCH ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process failed unexpectedly to fetch a notification event from RIB.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_SHMEM ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal Error: Shared memory error description.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-BAD_COMMAND_RESULT ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: EINT received a bad command result for BMA free buffer request.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTP2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_RES ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from RES, Reserved for Network Synchronisation), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-5-ERR_SHMWIN_MUTEX ### Response: (Severity: 5), (Category: ROUTING), (Description: NetIO or Mfwd terminated while holding shared mem mutex. Recovery action will be taken), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_ADVMASK ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to add itself to the advertising mask for the specified route and topology, that route corresponding to a connected route on an interface over which IS-IS is running. This means that any protocols which redistribute IS-IS into themselves will not receive the specified route. The problem is most likely to be caused by a failure by ipv4-io or ipv6-io to install the route at all, although it could also be due to low memory conditions.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-HARD_RESET_BLOCKED_BY_FIA ### Response: (Severity: 4), (Category: PLATFORM), (Description: Hard reset recovery action is temporary blockced untill FIA comes online. The network processor is in an unknown state and may not be operational.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_UPD-3-GOLDEN_UPGRADE_FAILURE ### Response: (Severity: 3), (Category: DRIVER), (Description: Golden PID firmware upgrade failed on PID and board may not be bootable post power cycle or reload as golden firmware corrupted. This cannot be upgraded via software again. The board need to be RMA'ed to fix this issue.), (Recommended Action: collect below logs on seeing this log before reloading or power-cycling the box 1. syslogs/console logs 2. show tech fpd 3. show tech obfl 4. show tech shelf-mgr 5. show tech ctrace 6. show tech fpd-serv) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-3-NO_POWER_FTV2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: 'The power needed for next V2 fantray exceeds the capability of the currently installed power supplies.'), (Recommended Action: - Please collect the following CLI command to determine the current budget situation and to see if there are any failed power modules. admin show environment power-supply - Install additional power supply modules and in case of presence of failed power module(s), replace those unit(s) until the alarm clears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_MPLS-3-WARNING_STR ### Response: (Severity: 3), (Category: L2), (Description: A runtime error occurred in ASR9K IPv6 FIB module. The reason for the failure is also displayed. Please call Cisco Support with the error information.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace [common|mpls] all loc <>). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-7-STAT_INFO ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-1-FC_IN_CRITICAL_STATE ### Response: (Severity: 1), (Category: PLATFORM), (Description: Both Fan controllers are not in working state which might damage the system. For the chassis to function normally, minimum one FC should be in XR state.), (Recommended Action: OIR and power enable atleast one FC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_SYSDB_BIND ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB failed to open a connection to the Sysdb Server process for one of the paths. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp router-id' command in IOS XR BGP configuration? ### Response: The 'bgp router-id' command is used to manually configure the BGP router ID. By default, the BGP router ID is chosen as the highest IP address configured on a loopback interface. If no loopback interface is configured, the highest IP address from the physical interfaces is chosen. Manually configuring the router ID provides stability in case of interface flaps. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How do you commit software changes to make them persistent across reloads in IOS XR? ### Response: To make software changes persistent across reloads, you need to commit them using the `install commit` command. For example\n```\nRP/0/RP0/CPU0:router# install commit\n```\nThis command commits the active software set to be used for subsequent reloads.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_5_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ASIC-3-INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: This is an internal error. Hardware or software is unable to initialize.The process will automatically respawn up to a fixed number of times to try and recover. Please check the error reason and description . %s - description of the error. %s - failure reason.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-PROCINIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during OSPFv3 process initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the additional following commands: - show tech-support routing ospfv3 detail) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-6-PASSWORD_READ ### Response: (Severity: 6), (Category: MGMT), (Description: This is expected in case password is read successfully, this may be temporary, retry with entering username/password would recover the issue), (Recommended Action: The issue should be recovered when retrying to enter username/password) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-CHKPT_SWITCHOVER_BEFORE_IDT_RCVD ### Response: (Severity: 4), (Category: L2), (Description: An RP switchover occurred before Checkpoint had fully mirrored MIB index values for Domains and Services to the standby RP. Thus, MIB indices may not have been preserved across the RP switchover.), (Recommended Action: CFM should still continue to operate normally, although MIB indices may have been lost.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS VPN central services feature? ### Response: The MPLS VPN central services feature allows MPLS VPN providers to offer centralized services, such as Internet access, to VPN customers. It enables traffic from VPN sites to be routed to a central site for services before reaching its final destination. Central services VPNs are implemented using route targets and BGP route importation at the central services PE router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_FM_LIB-6-V6_ANCHOR_PREFIX ### Response: (Severity: 6), (Category: L2), (Description: The IPv6 compression anchor prefixes are changed. The linecard needs to be reload to make the changes effective. This is not an error message or condition.), (Recommended Action: The IPv6 compression anchor prefixes are changed. The linecard needs to be reload to make the changes effective. This is not an error message or condition.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-PKT_INT_ERR_AT_ILIF_0_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Packet Integrity Error at link interface from NP/MUX on FIA), (Recommended Action: Verify correct link serdes error Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-NSF_CHKPT_INIT ### Response: (Severity: 4), (Category: ROUTING), (Description: The IS-IS process failed to initialize the checkpoint service for the specified error reason.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-3-COUNTER_OVERRUN ### Response: (Severity: 3), (Category: MGBL), (Description: The statistics infrastructure has received an update from a stats collector for which one or more values are erroneously high, and may cause the datarate calculation to wrap. This message indicates a bug exists in the relevant stats collector. The collector's node and jid will be indicated in the error message. The output of 'show statsd collector brief' can be used to determine what process the JID belongs to.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-CONFIG_OUT_OF_SYNC ### Response: (Severity: 3), (Category: LICENSE), (Description: Smart Licensing Configuration does not match the value of the enable flag in Trusted Store. This can happen if a configuration is copied onto the system and a reload occurs. If the new configuration does not contain the Smart Licensing Enable command, the value in Trusted Store will not match.), (Recommended Action: Apply the desired Smart Licensing Configuration Command and persist the configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-USER_DEF_PROFILE_LC_RELOAD_REQ ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: If the hw-module command is used to configure the user-defined TCAM key parameters and the lc is not reloaded, there will be inconsistency between the config in DPA and the hardware. Needs attention with line card reload.), (Recommended Action: Reload the affected lc for new profile to take effect.=======) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLCTRLR-4-ALARM ### Response: (Severity: 4), (Category: L2), (Description: The specified MLCTRLR Alarm has been declared or released.), (Recommended Action: Recommended action is to repair the source of the alarm.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BANNER-7-SYSDB_BIND_FAILURE ### Response: (Severity: 7), (Category: OS), (Description: Error binding to sysdb path), (Recommended Action: Copy the message exactly as it appears, andreport it your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-INVALID_BGP_PATH_FLAGS ### Response: (Severity: 3), (Category: ROUTING), (Description: Received an invalid combination of BGP path flags), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_NB_SERDES_4_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data north bound serdes link 4 failure on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-RSPI_ALIGN_MISMATCH ### Response: (Severity: 0), (Category: PLATFORM), (Description: RxSPI align 16B module control bits mismatch.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_Driver-1-UPGRADE_ALERT ### Response: (Severity: 1), (Category: INFRA), (Description: Update FPD upgrade alert), (Recommended Action: The reson for failed FPD upgrade to be analyzed. Please contact Cisco Technical) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSLA-5-THRESHOLD_SET ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_3 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, do SFP OIRs a few times. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SEG_HDR_EXT_FIFO_OFLOW_1_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress seg hdr ext fifo overflow on xaui-1 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the three planes that Cisco IOS XR uses to secure access to the router? ### Response: Cisco IOS XR uses three planes to secure access: 1) The admin plane which has full access to the entire router. 2) The SDR plane which has access to resources and configurations within a Secure Domain Router. 3) The management plane which has access to individual command-line interfaces. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-3-LOAD_INTERVAL_CONFIG ### Response: (Severity: 3), (Category: MGBL), (Description: The statistics infrastructure failed to apply load-interval configuration for some interfaces. This means that the data rates reported for the affected interfaces (in 'show interfaces', for example) may not cover the time periods specified in the running load-interval configuration.), (Recommended Action: Restart the global Stats Manager process (statsd_manager_g). If the error is still seen, re-apply the load-interval configuration for all interfaces. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP_NSR-3-NOTIFICATION_FAIL ### Response: (Severity: 3), (Category: IP), (Description: TCP was unable to queue an SSO related notification message towards its client. This may leave NSR operations impaired.), (Recommended Action: The process may attempt to recover from this situation by retrying the operation. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLDR-6-PARTNER_IS_UP ### Response: (Severity: 6), (Category: PLATFORM), (Description: Post switchover, this node has detected that it's partner RSP has come back up.), (Recommended Action: There is no action required. Every time a partner RSP undergoes switchover this will result in this message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-3-FIELD_ENTRY_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: DPA failed to create entry for the Group on this NPU.), (Recommended Action: The failure caould be because we ran out of available free entries for this Group on this NPU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISLM-4-ACCT_STOP_REC_FILE_INIT_FAILED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This syslog is printed when acct stop rec file init failed.), (Recommended Action: Check the harddisk space. Try disable and then enabling the accounting stop storage feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-KDUMP_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: OS running on the indicated card is reporting an error for kdump.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB-7-ERR_THREAD_MUTEX_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while creating a mutex for use by a client with the specified ID. This is crucial for the process and is automatically restarted on this failure.), (Recommended Action: If the problem is experienced only by this process in the system, restart the fabric server process by executing the following command at the CLI of the active RP: process restart fab_svr location If problem either persists (following a process restart) or also noticed on other processes then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-FSMTIMEOUT_RSP_ISOLATION ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node was in an isolated state from the rest of router for too long. The recovery action is taken automatically by shelf manager at this point by rebooting the affected node.), (Recommended Action: None is required, the shelf manager will reboot the isolated node to have it come out of isolation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_7_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_API-3-TLV_MSG_DECODE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that Shelf Manager TLVLIB failed to decode the TLV message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-4-RECONNECT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: STP has encountered an error while attempting to resynchronize its data with Interface Manager. The process will restart automatically to correct the problem.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_DRIVER-6-INTERRUPT ### Response: (Severity: 6), (Category: L2), (Description: HW interrupt occurs.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-MIPC_INIT ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when trying to initialize with Metro IPC server.), (Recommended Action: Check the status of Metro IPC Server because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-2-VIN_LOW_LEVEL_CRITICAL_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: 'Input voltage level is too low for this module, it crossed the critical alarm threshold'), (Recommended Action: 'Check/Charge the batteries.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-NO_CONFIG ### Response: (Severity: 3), (Category: OS), (Description: No configuration for PIFIB flow handling was found. Default characteristics will be used for all packets.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INVENTORY_PARSER-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an information log.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-MEMORY_PROTECT_FAILED ### Response: (Severity: 4), (Category: OS), (Description: Probably software bug, or OS bug. Dumper will be impacted by this.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLX8749_CDMA-3-LTRACE_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ltrace initialization has failed, this might be a program level issue), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-5-MSG_DLRSC_CPU_FAILOVER_NORMAL ### Response: (Severity: 5), (Category: PLATFORM), (Description: The backup-dlrsc CPU inst on standby DRP should failover ahead of the ndlrsc CPU instance. This is done when we detech that the Active DRP's CPU node went down.), (Recommended Action: None; this CPU will failover to active state) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_HFR-7-ERR_EVENT_CONN_NOTIFY ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to register event handler for disconnection or connection error event. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ether_spa_mac_error-1-SPA_SHUTDOWN ### Response: (Severity: 1), (Category: L2), (Description: MAC TX/RX FIFO ECC errors have occured. Auto-recovery attempts have also failed to recover the SPA. This is indicative of a hardware issue. Manual intervention is required.), (Recommended Action: If the problem persists try reloading the SPA. If reloading SPA doesn't fix the issue try below steps: 1. Re-insert the SPA and make sure it is seated properly. 2. If issue still exists, try moving the card to a different subslot or a differnet slot altogether. 3. If problem continues to exist after Step (2), replace SPA with a new one or contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_OUT_MEM_CORR_ECC_ERROR_LNK1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast output memory correctable ECC error on link 1), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_11_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_11 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-ACTIVE_SOFTWARE_COMMITTED_INFO ### Response: (Severity: 4), (Category: INSTALL), (Description: The currently active software has not yet been 'committed' to the system. This means that if the system reboots then the committed software will become active. Note that a failover will not cause the committed software to become active.), (Recommended Action: Verify that the system is operating as expected. Use 'system verify' to help validate the system. Use 'install verify' to validate the install sub-system. If the system is operating as expected then execute the 'install commit' command to commit the active software so that it is used if the system reboots.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHDLC_EA-4-ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occured during the initialization of the process. The process will restart which should recover the situation.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-CHKPT_INIT ### Response: (Severity: 3), (Category: SERVICES), (Description: Failed to register the application with the checkpointing server. This will impact the functionality of cgn_ma during switchover. CGN_MA will restart when we hit this issue.), (Recommended Action: If the issue persists after process restart, Please collect the following data and contact support. 1. show tech chkpt cgn_ma 2. cgn_ma traces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPT_SUB-4-WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is an severe error message in the DPT module to indicate that an error was seen during init operation.), (Recommended Action: Please collect the console log, DPT traces (show dpt trace loc <>), Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-QDR_MEM_ECC_FAIL_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: QDR memory ECC failure on bridge instance-1.), (Recommended Action: Please reload the board using the command 'reload location <>'. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-OFFLOAD_DECODE_FAILED ### Response: (Severity: 4), (Category: L2), (Description: An error occurred while attempting to decode a batch of offload messages which had been received. The source of the error is the offload infrastructure. The received messages will be dropped as a result of this error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-4-EAD_SRV6_SID_LIMIT ### Response: (Severity: 4), (Category: L2), (Description: There is a limit on the number of SRv6 SIDs that can be processed by EPVN in one path attribute. The number of SIDs currently supported is displayed in the message - the SIDs that are added that exceed this limit are dropped.), (Recommended Action: Currently EVPN supports receiving a maximum number of SRv6 SIDs. The network should be set up so that this limit is not exceeded. Please check that the configuration is correct before contacting support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-BFD_INVALID_NBR ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error indicating that an attempt has been made to create a BFD session for a neighbor type that is not supported by BFD.), (Recommended Action: The BFD session for the neighbor in the log will not be created. If a BFD session for this neighbor is not required, no further action is needed. To re-attempt creation of a BFD session for this neighbor, remove and re-add the bfd fast-detect configuration for the neighbor.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of TURBOBOOT in Cisco IOS XR? ### Response: TURBOBOOT is used in Cisco IOS XR for booting the system from a minimal state, often utilized during system recovery or initial software installation to load a specific software image. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-EXTERNALERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An external software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show tech-support routing ospf) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-RX_PLL_LOS ### Response: (Severity: 3), (Category: PLATFORM), (Description: SI5346 RX PLL loss of signal detected/cleared for RSP), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_RIB_RESET ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS initiated a reconnection to the RIB to recover from an error condition.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_THREAD_CREATE ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an unexpected error creating a new thread. The process will restart to attempt to recover. This is possibly due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-7-MISSING_CTX ### Response: (Severity: 7), (Category: HA), (Description: During a re-registration, an internal context structure was not found. This is probably a coding error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-INSTALL_PKG ### Response: (Severity: 6), (Category: OS), (Description: Active installed packages), (Recommended Action: Information of the active packages. No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-LINK_CREATE_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: An entry could not be placed in the links database. The full error message should indicate where the failure occured and why.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET-3-STATE_FSM ### Response: (Severity: 3), (Category: L2), (Description: An operational error occured when handling a port state event in the port state machine, and the internal state may be left in an inconsistent state without user intervention.), (Recommended Action: 'shutdown' and 'no shutdown' the affected interface, this should allow the state machine to recover its operational state. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-CHKSUM_ERR_0_FIA_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Checksum error - 0 from FIA on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-LWM_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-6-INFO_MSG ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message in the Egressq/Tor Driver to indicate an operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CSI_NETIO-5-UNSUP_MAJOR_VERSION ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: CSI DLL does not support DLL upgrade across major version changes. This will cause netio to take default action to restart for upgrade to take effect.), (Recommended Action: This message indicates that netio will take default action to restart as 'csi netio' dll does not support dll upgrade across major version number changes. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-2-INDUCED_GSP_UP ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message indicates that shelfmgr was induced to send out a gsp node-up notification for the given node by the user.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_UDI_MGR-3-ERROR_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The ASR9k License sync process exited due to a fatal error. Check the error string to determine what has happened.), (Recommended Action: Collect system log information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLARP_LITE-3-ERR_SHMEM_TRNC_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Attempt to truncate the shared memory file fails), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-0-PCIE_LINK_FAIL ### Response: (Severity: 0), (Category: PLATFORM), (Description: LC CPU controller driver detected FPGA access failure. This error message is thrown after observing consistent fpga access failures, one of the possible reason could be PCIE link down between PCIE switch and FPGA. or there could be software error in reading fpga.), (Recommended Action: Reload the LC that has the problem atleast three times. If problem persists, contact support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-5-MAP_RESOLVER_MAP_REQUEST_FILTERED ### Response: (Severity: 5), (Category: IP), (Description: 'Map-resolver filters incoming map-request if it does ' 'conform to the configured allowed-locator policy.'), (Recommended Action: 'Configure allowed-locator policy to permit the ' 'filtered map-request to get processed.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-5-NSR_INTF_TOPO_UNREADY ### Response: (Severity: 5), (Category: ROUTING), (Description: When ISIS just started, area or topology structures has not be setup yet, NII interface init needs to wait until they are ready.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-GEN_ERR_2 ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA driver encountered an Error in operation. The error string updates the reason for this error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPD-3-INIT ### Response: (Severity: 3), (Category: IP), (Description: An error occurred during initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-6-ERR_SOCKETFAIL ### Response: (Severity: 6), (Category: SECURITY), (Description: None at this time), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-6-LCL_ATTRIB_EXIT_OOR ### Response: (Severity: 6), (Category: ROUTING), (Description: The local attribute index database on the LC has resources available. The number of attributes programmed to local attribute index zero while the OOR state was red is displayed. If you wish to recover them, then issue a 'clear cef vrf '.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'install prepare' command in Cisco IOS XR? ### Response: The 'install prepare' command in Cisco IOS XR is used to pre-download software packages to the router and prepare them for activation, allowing for a smoother upgrade process. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-GENERIC_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: A generic RIB error is seen.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-POLICY_DECODE_FAIL ### Response: (Severity: 3), (Category: L2), (Description: CFM encountered an error while trying to decode a configured policy. This could indicate an issue with CFM or the Embedded Event Manager service. No Bandwidth Notifications will be executed for the affected policies.), (Recommended Action: Restarting the CFM Daemon on the node where the problem has occurred may help to resynchronize the system state. 'process restart cfmd location ' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFDIAGBASE-3-QUEUE_ERROR ### Response: (Severity: 3), (Category: DIAG), (Description: An software error occurred while performing the stated action (queue operation) on a packet or message. This is a serious error and could indicate memory corruption or a bug in the software. This is not a service impacting error.), (Recommended Action: Check the log ('show logging') to determine if there are any other related error messages. Also, please check Bug Navigator ( https://tools.cisco.com/bugsearch?referring_site=btk ) to search for any bugs in this area. Copy the error message exactly as it appears on the screen and gather any relevant information about the circumstances. Also collect the information from 'show logging' and 'show tech diagnostics' commands. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BPE-7-DEBUG_CONT ### Response: (Severity: 7), (Category: PLATFORM), (Description: This message indicates an condition occurred beyond which execution of the bpe_driver may continue), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-QDR_MEM_SELFTEST_FAIL_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: QDR memory self test failure on bridge instance-0.), (Recommended Action: Please reload the board using the command 'reload location <>'. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-NODE_CPU_RESET ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that the Shelfmgr detected the CPU of the specified node has reset. The specified node will attempt software reload.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-GET_REPLICA ### Response: (Severity: 7), (Category: OS), (Description: The Rds library couldnt get the replica entry when it queried for it. The entry might not have been updated.), (Recommended Action: This is a Debug message.No action required. If the problem persists,Contact Support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_HFR-7-ERR_NULL_ARGS ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to create thread due to internal error.), (Recommended Action: Restart the fabio_svr process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-IPSEC_CLOSE ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred when trying to close an IPSec SA for the named interface.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-LIST_IS_FULL ### Response: (Severity: 7), (Category: INSTALL), (Description: The Install infrastructure has encountered an unexpected state, and will be unable to process the current request or operation), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-BAD_ID_HW ### Response: (Severity: 3), (Category: DRIVER), (Description: Hardware in the specified location could not be identified as genuine Cisco product by card manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-PCIE_BAD_WRITE_ADDR ### Response: (Severity: 1), (Category: PLATFORM), (Description: CIB PCIe bad write address), (Recommended Action: Reset board) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR_EA_OOR-4-NP_FLOWS_OOR_RED ### Response: (Severity: 4), (Category: PLATFORM), (Description: Performance traffic monitoring has encountered an out-of-resource condition. Performance traffic monitoring process on the linecard has detected that the number of flows being monitored on a NP has reached maximum capacity. New flows will no longer be learnt), (Recommended Action: Reduce the number of flows being monitored on the NP. This can be done by 1) Modifying ACL: (a) Remove the performance traffic service policy from the interface (b) Modify the ACL used in the service policy to be more specific to match a smaller set of flows to be monitored (c) Reapply the service policy to the interface 2) Moving monitored flows to a different interface on a different NP) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-7-CAL_CHIP_PRINT_OPTION_SET_VAL ### Response: (Severity: 7), (Category: MGBL), (Description: Printing value of write_chip, set_system, calender and boot time flag set based on arugment.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_JBI-3-FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message from the FPGA upgrade facilitator , it indicates that something has gone wrong with FPGA programming.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_INVALID ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from invalid.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-3-ASSERT_MSG ### Response: (Severity: 3), (Category: OS), (Description: rds hit an internal assert. An unexpected error condition has been seen due to which RDS hit assert.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-2-SRSP_STANDBY_EOBC_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Standby RSP has detected an error with the standby eobc link between this standby RSP and one or more line card)(s)), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BANNER-3-CONFIG_INIT_FAILED ### Response: (Severity: 3), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM-3-BAD_VISIBLE_COUNT ### Response: (Severity: 3), (Category: IP), (Description: This is an internal error. It indicates that the addresses visible to the clients are more than expected. This can result in IP ARM not sending an address update to its clients.), (Recommended Action: Get the output of show tech-support, show arm [ipv4/ipv6] trace, running coredump of the process. Unconfiguring, reconfiguring the interface may help in recovering the from error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-HW_DETECTED_ERROR_ISN ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cpuctrl driver HW error interrupt handler was invoked and found valid PCI ISN register from a Cpuctrl Internal Access failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ST16550-3-STATUS_MUTEX_LOCK_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The ST16550 UART driver was unable to lock the status variable for the interrupt thread.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_BAG ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the Bag Client library. The error message describes what operation has failed and why it failed. The most likely reason for this a low memory condition but the error could also be caused by a programming error. The error will affect PPP MA's ability to provide operational management data, but won't otherwise affect PPP MA's operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_MAIN-5-CLOCK_ACCURACY_LEGACY ### Response: (Severity: 5), (Category: PLATFORM), (Description: The system timing is switching to legacy accuracy mode as a result of removing the 'timing-accuracy enhanced' configuration. This switching operation may result in a transient flap in timing (PTP/SyncE) or in the PLL states. This is an expected behaviour and no further action is needed from the user.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install verify platform command in IOS XR? ### Response: The 'install verify platform' command is used to verify that the router's hardware platform is compatible with the software packages being installed. It checks the hardware components and their revisions against the requirements of the software and reports any compatibility issues found. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPI-3-FILE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occured while reading the file), (Recommended Action: Try to rerun the CLI, if it fails repeatedly contact support. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRD-3-ASSERT ### Response: (Severity: 3), (Category: SERVICES), (Description: The process is in an inconsistent state. The process will exit and restart. All data will be resynchronised after the restart.), (Recommended Action: No action is required to recover the system, this will happen automatically. Report this issue to your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KENSHO_GL-3-INIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Procmgr encountered an error during initialization resulting in restarting the Procmgr process. This may be a program level error. The failure will cause the Procmgr process to restart.), (Recommended Action: The Procmgr process will automatically respawn up to a fixed number of times. Verify the process is running: 'show process procmgr location <>' If it is still non-operational, execute 'process restart procmgr location <>'. If it the process still fails to spawn, contact support with the required info. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-IIR_MDR_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'IIR Callback evoked after MDR Shutdown start.' 'This will not effect the process.' 'This operation is optional '), (Recommended Action: 'ISSU manager will use some other API' 'If the issue persists ' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_PAK_RECV ### Response: (Severity: 3), (Category: ROUTING), (Description: Error encountered during RIP packet receive operation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FT-3-UNSUPPORTED_FAN ### Response: (Severity: 3), (Category: LIBRARY), (Description: The type of fan is not supported in the release.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VCDMA-3-ERR_EVM_NOTIFY ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cpuctrl Event Manager notify error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-5-AUTHORIZATION_EXPIRED ### Response: (Severity: 5), (Category: LICENSE), (Description: The device has not communicated with Cisco for an extended period of time and the device has not automatically renewed the entitlement authorizations.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-IM_ATTR_INIT ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to initialize the IM attribute library. This error will prevent IS-IS from normal operations.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the IS-IS process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEAT_MGR-3-UIDB_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: UIDB stores the reference to ACL entries programmed in TCAM for the interface, protocol and direction. This error message is due to one of the following reasons: 1. Initialization failure of Feature Manager and UIDB manager interface. 2. Failure to set reference of hardware entries programmed or removed for security ACL in UIDB on configuration or system changes. This failure can lead to mismatch between hardware and software configuration.), (Recommended Action: If the failure is on initialization, process restart is done automatically. No manual action is required. If the failure is to set configuration bits in hardware on detaching a security ACL from interface, attach and detach security ACL again on the interface. In all other cases, detach ACL in the error message from all interfaces of the line card where issue is seen. Now, re-attach ACL to the interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMACTRLR-4-UPDOWN ### Response: (Severity: 4), (Category: L2), (Description: The specified IMACTRLR is operationally down due to alarm. Check alarm status using show controller Mlt command on the cli.), (Recommended Action: Recommended action is to repair the source of the alarm.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-3-ERR_SYSDB_GET ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-4-DLL_LIST_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: During the processing of a software change notice, the command to get a list of dlls that this process had open failed. The routine will now attempt to fall back on default disposition.), (Recommended Action: Check the install logs if all the packages are downloaded and install operations completed properly Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-3-NO_POWER_AVAILABLE ### Response: (Severity: 3), (Category: PLATFORM), (Description: 'The power needed for shelf equipment exceeds the capability of the currently installed power supplies.'), (Recommended Action: - Please collect the following CLI command to determine the current budget situation and to see if there are any failed power modules. admin show environment power-supply - Install additional power supply modules and in case of presence of failed power module(s), replace those unit(s) until the alarm clears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-7-ASYNC_SEND ### Response: (Severity: 7), (Category: PLATFORM), (Description: This message indicates sc-reddrv failed to send redundancy status to RMF.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-FALLBACK_CLEANUP_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: Transaction cleanup failed when booting from the fallback software image.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-5-CD_STATE_CHANGED ### Response: (Severity: 5), (Category: SERVICES), (Description: 'CD L2 or Reuse Channel Created/Removed/Expired'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPM-3-ERROR_REPLY_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: The system could not reply to the message that was sent by the client.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-SLOTORDER_REGISTER ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to register the slot order display failed. The error is displayed in the message'), (Recommended Action: Collect show nvgen trace, show logging and send this to tech support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-INIT_REGISTER_DEBUG_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failed to register with debug. This would prevent process from logging debug messages.), (Recommended Action: No action is required. Process will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If restart din't fix the problem) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_ERRORS-7-ERR_SYSDB_EDM_REG ### Response: (Severity: 7), (Category: L2), (Description: The ASIC Error library was unable to become an external data manager despite having a connection to the SYSDB.), (Recommended Action: An error would be reported to the client application which should handle this condition appropriately. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-3-CREATE ### Response: (Severity: 3), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_TUNNEL_EA-3-PARAM_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the CRS platform specific code software which occured due to some problem in the parameters passed. %s - indicates the reason for the failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_SERVER-3-I2C_WRITE_FAIL ### Response: (Severity: 3), (Category: L2), (Description: An error occured while writing to I2C device. This may be a program level error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-MISCONFIG_CAP_SUPPRESS_ALL ### Response: (Severity: 4), (Category: ROUTING), (Description: Possible misconfiguration with 'capability suppress all'. The neighbor's remote-as is a 4byte AS number which is incompatible with this configuration which suppresses negotiation of all capabilities for this neighbor.), (Recommended Action: Check the bgp configuration for this neighbor and ensure that none of the neighbor's configuration require Capabilities negotiation, or remove the 'capability suppress all' configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: G8032-6-APS_CHANNEL_ACTIVE ### Response: (Severity: 6), (Category: L2), (Description: A ring node, which was had previously not received R-APS messages for an extended period of time, is now receiving R-APS messages. A properly functioning ring will have an R-APS messages transmitted nominally every 5 seconds), (Recommended Action: As R-APS messages are now being recieved as expected, no further action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-MSG_SEND_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: --), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-6-CHECK_FABRIC_CONN ### Response: (Severity: 6), (Category: PLATFORM), (Description: Control ethernet connection is lost. Checking fabric connectivity to decide if reset needs to be done), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTAGENT-2-ADMIN_HOST_VERSION_MISMATCH ### Response: (Severity: 2), (Category: INFRA), (Description: The install software component has detected that the local installed software on host and sysadmin are not same relative to the software installed on the rest of the system. This event may be caused by the reloading the sysadmin after system upgrade or ISSU without doing install commit.), (Recommended Action: This node has to be manually reloaded using 'hw-module location reload' command. To get more information on what caused this event, you can run the command 'show tech-support install'. If the problem happens after reload as well then node has to be reimaged/rebaked.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HPI-3-SHM_DEVICE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to find the HPI device's corresponding shared memory. %s-Function name. %d-Client ID. %s-Error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROL_DRIVER-3-BOARD_INCOMPAT ### Response: (Severity: 3), (Category: DRIVER), (Description: This indicates that there is an incompatibility between Active and Standby RSP4 boards which may lead to mismatch in synchronization between Active and Standby Configuration), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDS_CONSUMER_LIB-3-NULL_CONSUMER ### Response: (Severity: 3), (Category: OS), (Description: cds lib has got a message to process, but consumer has not yet registered. please collect cds consumer ltrace.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-5-ERR_CONT ### Response: (Severity: 5), (Category: PLATFORM), (Description: This message indicates an error occurred beyond which execution of the Interrupt controller_driver may continue, attempting to effect recovery or work-around internally, minimizing loss of information/functionality.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PVSTAG-3-INTERFACE_RECOVERY_FAIL ### Response: (Severity: 3), (Category: L2), (Description: If an error occurs while retriving sub-interface information from the system, PVSTAG attempts to recover automatically. This message is seen if that attempt to recover fails, or if more than the maximum number of attempts have been made. After this error is seen, it is likely that PVSTAG will not operate correctly for some VLANs.), (Recommended Action: It may be possible to recover by restarting the pvstag-io process on the affected line card, using the 'process restart' command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POS-2-ERR_INTERFACE_CREATE ### Response: (Severity: 2), (Category: L2), (Description: The interface creation in IM faces some issue as there was some resource failure detected.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - Check Memory conditions in the system) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IF_DRV-6-TRANSCEIVER_OIRIN ### Response: (Severity: 6), (Category: PLATFORM), (Description: TRANSCEIVER entity is inserted), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-GRE_KEY_OPTION_REQUIRED ### Response: (Severity: 3), (Category: IP), (Description: GRE Key option is required, but missing in the PBU.), (Recommended Action: Ensure that GRE encapsulation is configured on the MAG. If the issue is seen repeatedly, do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-5-OPTICS_OIR ### Response: (Severity: 5), (Category: L2), (Description: The Optic Module (CPAK/QSFP/SFP+) for the specified port has either been inserted or removed. %s - either 'inserted' or 'removed' %d - port number.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_400G_POD-3-HIGH_TEMP ### Response: (Severity: 3), (Category: FABRIC), (Description: The POD detects a high temperature. The POD might not be functioning properly, and can cause cell drops or corruption in the rx or tx link associated with the POD.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_DISC-3-PARTICLE_SMALL_POOL_DEFINE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Define particle pools over memory regions. If there is not enough space to hold all the particles, less particles will be created. Each pool can have its own particle size. Particle defined as Small pool got failed.), (Recommended Action: Copy the System Message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_1_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser bias less than or equal to the low laser bias warning threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-EBS_OC_PKT_LTH_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: EBS from FIA packet length mismatch error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-6-MLACP_DISCONNECT ### Response: (Severity: 6), (Category: L2), (Description: mLACP has disconnected from the specified devices.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SKIP_CPU_INFO ### Response: (Severity: 7), (Category: OS), (Description: Skipped CPU info dumping in OS debug info, as it's requested by the target process. Down time critical processes which can't afford extra core dump time due to CPU info, might request this skipping.), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_EDM-3-DATALIST_CREATE_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The creation of the external data manager datalist has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_4P_OC192-3-DEVICE_INTR_CLEAR ### Response: (Severity: 3), (Category: L2), (Description: The previously reported excessive interrupts condition has been cleared. Interrupt rate limiting has been disabled.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_CHKPT_DUPLICATE ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: Whilst restoring one of its checkpoint tables PPPoE MA found multiple entries for the same interface. PPPoE MA will use the first checkpoint entry it finds for each interface and ignore any subsequent duplicates. This is caused by a programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_MAP-4-OOR_OK ### Response: (Severity: 4), (Category: ROUTING), (Description: This router has fallen below the maximum value for the number of cache entries allowed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCT_MA-3-PLCYMAP_UNDEFINED ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: The policy-map name that was configured in the service type dynamic-template has not been defined in the system.), (Recommended Action: Define a policy-map with the name used in the service-policy command or change the name in the command to an existing policy-map. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-6-SAT_UNQUAL_PPM ### Response: (Severity: 6), (Category: PLATFORM), (Description: The Unqualified PPM Inserted condition occurs when a PPM with a nonqualified product ID is plugged into the card's port; that is, the PPM passes the security code check as a Cisco PPM but is not qualified for use on the particular card.), (Recommended Action: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRD-3-INIT_FAILED ### Response: (Severity: 3), (Category: SERVICES), (Description: The Service Role Daemon has failed to start up. The operation being attempted is detailed in the error message. The Service Role Daemon will be restarted automatically.), (Recommended Action: If the error indicates an Out Of Memory error, then attempt to increase the available resources. Otherwise, if the error persists, contact your technical support representative copying the error message exactly as it appears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-FGID_ALLOCATE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while allocating FGID array. This may be due to - number of FGID passed exceeds set limit dues to message size limit - Low available memory - Passed fgid_type is NULL), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-INIT_ACL_UPDATE_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failed to initialize callback functions for receiving updates for IPv4/IPv6 security ACL configuration.), (Recommended Action: No action is required. Process will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If restart din't fix the problem) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_SHMEM_CLIENT ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal Error: Shared memory client error description.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PA_FF-4-TIMER_SETTIME ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when arming a timer using timer_settime.), (Recommended Action: Restarting the lpts_pa may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-INVALID_UPCOMING_LEAP_SECOND ### Response: (Severity: 4), (Category: L2), (Description: A leap second event scheduled for midnight tonight will result in the UTC offset changing by more than one second. This is an invalid change since the final minute of the current day may only contain 59, 60 or 61 seconds.), (Recommended Action: This error suggests a misconfiguration. If using leap second offset configuration, adjust the configuration such that the UTC offset will only change by one second. If using leap second file configuration, check the file for consecutive entries which differ by more than one second.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-PCIE_TXIF_FIFO_MBE ### Response: (Severity: 0), (Category: PLATFORM), (Description: CIB PCIe Tx interface FIFO multiple bits error.), (Recommended Action: Reset the board) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-3-SET_RLIMIT ### Response: (Severity: 3), (Category: OS), (Description: QNET process tried to set the rlimit for the process but encountered error The process will exit and retry again), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-SERDES_ERROR_LNK3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected a serdes error on link 3.), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. Also, check for any damage to the card and its backplane connectors. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-0-LC_DP_SWITCH_LOOPBACK_FAILED ### Response: (Severity: 0), (Category: PLATFORM), (Description: --), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-7-UNEXPECTED ### Response: (Severity: 7), (Category: HA), (Description: An unexpected condition encountered. This is not necessarily an error, but may help with debugging other problems elsewhere.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-SATELLITE_FABRIC_VERSION_UNSUPPORTED ### Response: (Severity: 3), (Category: L2), (Description: There are some Satellites in the fabric which are not compatible with the configured 'network' version of the 'CFM on Satellite Fabric Links' feature. All fabric links to/from those satellites will be unprotected.), (Recommended Action: Ensure that the CFM Satellite fabric link configuration type matches the capabilities of the Satellite devices and expected fabric protection.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-4-SD_ERR ### Response: (Severity: 4), (Category: SERVICES), (Description: When a service attachment (e.g. a firewall attachment) is configured on an interface, the local RSPP MA process (the service diversion management agent) must request information on the attached service from Service Director to be able to implement the required diversion. This error indicates that a problem has arisen in this request. The error string given should give more details on the error that has occurred.), (Recommended Action: For non-resource errors, removing and adding back the configuration that prompted the message may remove the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the error is a resource error this will be indicated in the error description given. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_ETHERNET-3-CTRLR_SETUP_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A failure occurred initializing a new Ethernet controller. The controller cannot be created with the supplied parameters and must be deleted before attempting to create with valid parameters. Until this is resolved the port will not be able to carry an Ethernet signal.), (Recommended Action: If this is seen following a SMU install then uninstalling the SMU may workaround the issue whilst seeking support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls ldp igp sync' command in IOS XR? ### Response: The 'mpls ldp igp sync' command is used to enable LDP-IGP synchronization. This feature ensures that LDP is fully operational on a link before the link is used for forwarding traffic. It prevents traffic loss during IGP convergence by delaying the use of a link for forwarding until LDP has converged on that link. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM-7-LTRACE_INIT_ERR ### Response: (Severity: 7), (Category: IP), (Description: IP ARM failed to initialize module to allow tracing of important events. This may happen during process (re)start. The process will exit and try to recover from the error.), (Recommended Action: If the msg is not seen multiple times, it can be assumed that the process has recovered. If the process cannot recover from this error, it may not be able to run. Then it is a fatal error. Collect the output of show tech-support, show arm [ipv4/ipv6] trace.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-1-ERR_BOARD_POWER_FAULT ### Response: (Severity: 1), (Category: FABRIC), (Description: Fabric board is not operational due to the a power fault.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-STANDBY_NOT_READY ### Response: (Severity: 4), (Category: INSTALL), (Description: Install director expected standby nodes to be ready, however, when verifying found at least one that is not ready.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_LOL_MAPPERA ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-6-MAL_DATA_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Info about media access lib, used to communicate with linux ethernet device driver. %s- Message description. %d- Value of the parameter described above.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key characteristics of the Group Services Protocol (GSP) IPC? ### Response: GSP is a connectionless asynchronous multicast-based IPC mechanism. Key characteristics include\n- Uses publish/subscribe model - senders and receivers join multicast groups\n- Supports one-to-many communication efficiently\n- Sender not blocked, leading to higher throughput\n- Messages can be sent to all group members or a filtered subset\n- Reliable delivery with ack/nack from receivers\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-SERVER_MUTEX_INIT_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-7-DEBUG_REGISTER ### Response: (Severity: 7), (Category: HA), (Description: Registration of debug services failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-BAD_DIR_PREFIX ### Response: (Severity: 7), (Category: INSTALL), (Description: The Package infrastructure could not determine which cards a particular file belongs to. Either the PIE file is corrupt, or the Package infrastructure is behaving incorrectly. The current request or operation will not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-3-EXIT_ERROR ### Response: (Severity: 3), (Category: LICENSE), (Description: The license manager encountered a error condition during intialization this could happen due to platform service initialization error like EVM service failed ,trace server init failure etc . All these are unlikely failure but if it occur it could be resolved during restart of licmgr process .), (Recommended Action: Please restart the licmgr process command 'admin process restart licmgr'. Another option is reloading the RP card by command 'admin reload'. If the error log messages is reoccuring , please collect information using the commands 'show tech-support license ','show license trace platform' and contact your tech support representative and provide them the collected information and exact message as displayed on screen.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-MAC_1_TX_FIFO_OFLOW_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: MAC on NPU-1 had transmit fifo overflow on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2CCTRL-2-IO_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: I/O Communications Failure with a Device on the I2C Bus), (Recommended Action: Please attempt to correct the error by reloading the card by issuing the command in admin mode -reload location <> If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-6-C_SHIM_QUERY_INTERNAL_ENTERED ### Response: (Severity: 6), (Category: L2), (Description: Debug information - Indicates control reached a particular functionality.), (Recommended Action: *None*.Informational message only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-EVENT_MANAGER_CREATE ### Response: (Severity: 3), (Category: MGBL), (Description: The call to event_manager_create() failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-AF_LIB_FILE_WRONG_INFO ### Response: (Severity: 3), (Category: ROUTING), (Description: 'The data in the Address Family data file was corrupt'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_29 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PA_FF-4-TIMER_CREATE ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when creating a timer using timer_create.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: attestation_agent-3-EVENT_LOG_NOT_FOUND ### Response: (Severity: 3), (Category: MGBL), (Description: A failure occurred during the event log open process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_CLIENT-3-DLL_NOT_PROVIDED ### Response: (Severity: 3), (Category: HA), (Description: Every chkpt client that requires mirroring should provide call back DLL to handle the endian neutral transformation. If DLL is not provided, check pointed records might get corrupted in mixed endian mode RP.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-CFG_WRITE ### Response: (Severity: 7), (Category: SYSDB), (Description: A non-management client illegally modified part of the system configuration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-7-LINK_SHUT_DOWN ### Response: (Severity: 7), (Category: FABRIC), (Description: The Fabric driver encountered an error on the annunciated Fabric Switching Element link and the link is brought down.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-3-SWITCHOVER_SUPPORT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message has failed. As a result, the mentioned driver on the card that puts this message will not be notified of failover of RP.), (Recommended Action: Restart the mentioned driver on the card that puts this message. If it is still non-operational,Collect the console error messages exactly as it appears on the console and call cisco support engineers with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-SHRINK_IPV4_6ADDRESS_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: Shrinking of expanded ipv4_6address failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'metric-style' command in IS-IS configuration? ### Response: The 'metric-style' command is used to configure the type of metric used by IS-IS. The options are 'narrow' (default) which uses 6-bit metrics, 'wide' which uses 24-bit or 32-bit metrics for greater scalability, and 'transition' which allows both narrow and wide metrics during a transition period. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-6-INFO_GENERAL ### Response: (Severity: 6), (Category: SECURITY), (Description: The sshd encountered some problem in genric nature or plain information.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTNSEC-2-SESSION_SECURED ### Response: (Severity: 2), (Category: SECURITY), (Description: Otnsec session is secured), (Recommended Action: No action required (Normal Operation).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLL-3-UPGRADE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Firmware upgrade failed for the PLL device. Collect show tech-support platform timing for further investigation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-7-BOARD_POWERUP_NOT_HAPPENED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVE-3-AC_DELETE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: Error was encountered in AC delete for the specified vni. This error may \ rectify itself, but in some cases can cause vni to be programmed \ incorrectly, resulting in traffic loss.), (Recommended Action: Please try to unconfigure and reconfigure the vni. If the same error is \ seen again, please contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_8_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: ROUTING), (Description: Allocation of memory failed.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_REX-3-MSG_REPLY ### Response: (Severity: 3), (Category: SERVICES), (Description: The diversion manager process was unable to send a reply to a message sent to one of its clients. Diversion information may be inconsistent.), (Recommended Action: Restarting the rspp_rex and fwc processes should clear the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-5-TCAM_MISMATCH_DETECTED ### Response: (Severity: 5), (Category: L2), (Description: This message indicates the detection of an inconsistency between the LC CPU software view of TCAM content, and what is actually found in hardware. Recovery is initiated automatically upon detection of such a mismatch. Once recovery completes, troubleshooting information is collected. Further messages, namely 'TCAM_MISMATCH_REPAIRED' and then 'TCAM_MISMATCH_COMPLETED', follow when the recovery and the data collection are completed, respectively.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-BPM_ROUTER_ID ### Response: (Severity: 5), (Category: ROUTING), (Description: IPARM returned no valid router ID. This is due to lack of a global router ID or a loopback interface.), (Recommended Action: Try one of the following: 1) Set up a BGP router ID via the `bgp router-id' command in the `router bgp' configuration mode, or 2) Set up a global router ID via the `router-id' command in the global configuration mode, or 3) Set up a loopback interface with an IPv4 address.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-ERR_HW ### Response: (Severity: 4), (Category: L2), (Description: A hardware error is detected on the PLIM. Software will take action as described in the error message, if not none, to try to recover from the error. The hardware error and the software recovery action will not impact traffic. Device: %s%s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Software action: %s - the action that software will take to try to recover from the error. Recommended user action: %s - recommended action to the user. Possible values: 'none' 'replace CFP' 'PLEASE MANUAULLY RELOAD THE LC AT NEXT MAINTENANCE WINDOW'), (Recommended Action: Take the recommended user action as it is described in the error message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-MISSING_IDB ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: EINT was supplied with a plim interface that does not have an idb yet.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of Install Manager in IOS XR? ### Response: Install Manager in IOS XR controls the booting process on each node in the system and determines the proper packages that need to be loaded on each node. It provides the user with the CLI necessary to carry out install operations. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_MVPN_ID_MISMATCH ### Response: (Severity: 3), (Category: ROUTING), (Description: MVPN ID Mismatch found.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-2-LC_EOBC_FAILED_BOTH_RSP ### Response: (Severity: 2), (Category: PLATFORM), (Description: This line card has lost EOBC heartbeat to both RSPs), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-RX_ALARM_FRAME_ERR_SYNC_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: For UTI mode alarm is raised if frame error rate exceeds 2%.), (Recommended Action: 1) Ensure valid BITS/UTI signal is applied at input port.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-IDB_CTX_NULL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: While processing an ingress packet, the eint driver failed to find idb context), (Recommended Action: Collect console log and the following information and contact TAC support with this info Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. -show process spp -show process netio -debug netio drivers location -show logging process spp -show logging process netio -show logging start [time of day when this msg was seen] -show netio idb all brief location -show netio trace all location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-INTF_DELETE_FAIL ### Response: (Severity: 3), (Category: QOS), (Description: QMgr encountered an error during the de-allocation of queueing resources within a queuing asic as part of interface delete.), (Recommended Action: Interface delete failed. No action needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_VKG-7-ERR_EDM_REGISTER ### Response: (Severity: 7), (Category: ROUTING), (Description: The MFWD-ASR9K library encountered internal error during EDM init setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-4-OOR_PROT_START_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is a warning message in the DNX FIB to indicate the usage of the named resource has exceeded the maximum allowed and we begin OOR protection for the resource.), (Recommended Action: Reduce usage of the named resource if the issue is persistent.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-4-UNRELIABLE_INFO_MSG ### Response: (Severity: 4), (Category: SECURITY), (Description: Received INFO message before peer has been authenticated that is why it is called unreliable.), (Recommended Action: 'Contact the remote peer's administrator') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-HIGH_VOLTAGE_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP voltage greater than or equal to the high voltage warning threshold. The CFP is the pluggable optics on the line cards. The voltage threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check the 'show environment voltages'. If the system voltage is normal then replace the optics with working one (if any). If the system voltage is not normal, then make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-5-PROCESS_UPDATE ### Response: (Severity: 5), (Category: TOPOLOGY), (Description: System Admin Manager got notification from process manager about process/system health.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEM-6-PAYLOAD_NOT_MULTIPLE ### Response: (Severity: 6), (Category: L2), (Description: A value in class attach onto interface or controller not inherited.), (Recommended Action: No Action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-FANTRAY_DETECTION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process failed to detect the fantray prescence), (Recommended Action: Check fantrays are properly seated.If no try re-seating the fan trays. If Still the issue persist after re-seating collect the required info Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_LOSS_OF_LOCK ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HPI-6-NO_BUF_TO_REPLACE ### Response: (Severity: 6), (Category: PLATFORM), (Description: CPUCTRL RX PDMA ring could not replace the buffers. possible low buffer condition.), (Recommended Action: Check for packet memory particle allocation and usage with 'show packet-memory', 'show packet-memory inuse' and 'show packet-memory old'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XML_TTY-7-LOGIN ### Response: (Severity: 7), (Category: MGBL), (Description: An internal error has occurred in the XML Dedicated Agent. The logint authentication (over dedicated) may not be able to complete correctly.), (Recommended Action: Retry the XML request that had the error. Transient conditions should have passed, and in all likelihood, this request will go through. If not, close this TTY session, and restart a new TTY session. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-4-INIT_FAILED ### Response: (Severity: 4), (Category: MGBL), (Description: An error was encountered while the Central Configuration Validator (CCV) was initializing. Attempts to modify system configuration while the CCV is not running may fail. The error message contains details about the source of the error.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_ATOM-7-DEBUG_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB ATOM component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-CF_MBE_ERR_FIA11 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA11 channel FIFO multi-bit error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-7-ISSU_LOAD_DONE ### Response: (Severity: 7), (Category: MGBL), (Description: 'ISSU install notification message for LOAD DONE Phase received'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSS-3-ERR_SYSDB_BIND ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric statistics server process encountered an error to bind to admin plane sysdb server. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_SERVER-6-START ### Response: (Severity: 6), (Category: L2), (Description: Informational message indicating the ASIC SCAN is started.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6-6-PACKET_DISCARD ### Response: (Severity: 6), (Category: IP), (Description: IPV6_IO discarded a packet due to the indicated error.), (Recommended Action: Based on the error indicated, investigate the source of the and links for packet corruption or other errors.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-3-ERROR_1_PARAM ### Response: (Severity: 3), (Category: SECURITY), (Description: SAM general error message with one prameter.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMS-3-GSP_EVQ_HANDLE_FAIL ### Response: (Severity: 3), (Category: SYSDB), (Description: We are dequeuing an invalidly TAGGED message for transmission This should not cause failures of any kind, but probably does indicate an error in another part of the system.), (Recommended Action: Collect show tech sysdb and show tech gsp. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_ENA-3-MEMORY ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP ENA filesystem handler was unable to allocate the required amount of memory, as the HTTP process has run out of resources. The HTTP process may no longer be able to function correctly, and may need restarting if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIB-3-NOMEM_ERROR ### Response: (Severity: 3), (Category: SNMP), (Description: The requested operation could not be performed due to a low memory condition.), (Recommended Action: 'Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-7-ERR_EVM_FAIL ### Response: (Severity: 7), (Category: L2), (Description: An internal error was detected when trying to create EVM connection. It can fail during following scenarios: 1) EDM registration/connect/notify. 2) BAG's rule registration failed.), (Recommended Action: No action is required. The process retries automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-6-LEAD ### Response: (Severity: 6), (Category: TOPOLOGY), (Description: System Admin Manager has got notification about the lead selection as specified.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-3-ROUTE_HDLR_CERR ### Response: (Severity: 3), (Category: L2), (Description: An error occurred in the L2FIB manager process. This could have occurred due to failure in receiving a valid route type for Multicast or EVPN. The message may not be delivered correctly if this error occurs. The error message prints the name of the route type.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_UIDB-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Informational message. No action needed), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-5-PORT_MOVE ### Response: (Severity: 5), (Category: IP), (Description: A port up message was received from an adjacency with a different sender name as compared to the sender name received from the previous port up message. The software has performed operation to associate this adjacency with the new sender name; however, it may not be the desired result, since duplicate ports could have been configured on external devices.), (Recommended Action: The configuration on the remote ANCP client should be evaluated for duplicate port circuit names on remote ANCP client devices.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_EVQ_CREATE ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This is an unexpected error. The PPPoE MA process will attempt to recover by restarting. The cause may be a resource starvation problem. The error message should provide more details.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR_ASIC-4-JER_ILKN_PORT_DOWN ### Response: (Severity: 4), (Category: FABRIC), (Description: 1. For ILKN port is in error state : This port is in error state due to errors on the link.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSMGR-6-INFO ### Response: (Severity: 6), (Category: OS), (Description: Informational only.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_SYSLOG_PRX-3-ERR_SYSDB_DELETE ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD_NETIO_TOPAZ_DLL-3-ATTACH_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: FWD was not able to attach to plim interface .), (Recommended Action: No Action required Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-UBLAZE_CPU_HOG ### Response: (Severity: 4), (Category: DRIVER), (Description: CCC FPGA is indicating that the CCC MicroBlaze CPU is experiencing a 'CPU hog' type event, which indicates that a MicroBlaze main loop iteration took more than this 50 milliseconds. A typical main loop iteration time is 15 milliseconds, but having multiple tasks (SPI, I2C, Ethernet, console mappings, packet push, PON, etc.) to complete during the main loop may increase this typical time.), (Recommended Action: This is a performance monitoring type message, there is no action required for user to correct the situation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CVAC-2-INIT_FAILED ### Response: (Severity: 2), (Category: MGBL), (Description: The CVAC (Cisco Virtual Appliance Configuration) subsystem failed at startup and was unable to run successfully. The subsystem will attempt to run again after the next reload of the router.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-4-REIMAGE_INITIATED ### Response: (Severity: 4), (Category: INFRA), (Description: ZTP has started loading the new image and router may get reload on completion.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-3-SYSDB_REG_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: A fatal error was encountered during initialization.), (Recommended Action: If the process does not restart automatically then try manually restarting it. A likely cause for this error is that the system has run out of memory. If this is not an out-of-memory problem and restarting the process does not solve it then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-CHECKPT_MEM_RESTORE_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Shelfmgr failed to restore its checkpoint memory on a process restart or transition from stby to act.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_DRIVER-3-INIT ### Response: (Severity: 3), (Category: L2), (Description: Driver initialization error), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-3-MACSEC_POWER_STATUS_ERR ### Response: (Severity: 3), (Category: L2), (Description: This would be seen when there is insufficient power (or) failed to allocate power which required for running the port in MACsec mode (or) failed to release power on removing the macsec config from the port or by configuring macsec shutdown.), (Recommended Action: In case of insufficient power, delete macsec configuration from the interface and reapply only after adding adequate power modules. In case of failed to allocate power (or) failed to release power, contact cisco-support by sharing the tech-support macsec.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_BAG_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: EDM Bags are used to share information between components using sysdb. This Error indicates that bag registration failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MGID_PROTECTED_FABRIC-4-MGID_RESYNC_END ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_AAA_ATTR ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA encountered an error using AAA attribute APIs. The error message describes what operation has failed and why it failed. The most likely reason for this a low memory condition but the error could also be caused by a programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_HQ_SEQ_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue sequence error on XAUI 1 HQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between a session-group and a neighbor-group in IOS XR BGP configuration? ### Response: A session-group defines common session parameters such as timers, transport mode (TCP or TCP-AO), update-source, and so on. A neighbor-group defines common neighbor parameters such as remote-as, route-policy in/out, next-hop-self, and so on. A neighbor can inherit from both a session-group and a neighbor-group. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-ERR_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: The Ingressq driver failed to initialize the device resulting in the restart of the Ingressq driver process.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the ingressq driver is up and running by executing the following command at the CLI of the active RP: 'show process ingressq location < >' If it is still non-operational, enable the following debugs of the ingressq driver process: error Errors in the driver fatal Fatal errors which cause driver to exit info All informational events init Initialization events and restart the driver by executing the following command at the CLI of the active RP: 'process restart ingressq location < >' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHER-4-BUNDLE_MAC_ADDRESS_WARNING ### Response: (Severity: 4), (Category: L2), (Description: The bundle MAC address failed to be programmed as the MAC address is currently associated with another client (most likely HSRP/VRRP).), (Recommended Action: Check HSRP/VRRP configuration associated with this bundle interface or children subinterface for the unicast MAC address shown. If the unicast MAC address is configured, reconfiguration of HSRP of VRRP should be considered.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ATTR_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message in the OFA FIB to indicate that engine layer identified an error with attribute padnxd by upper layers), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-4-WARNING_RT ### Response: (Severity: 4), (Category: PLATFORM), (Description: Warning related to rate limitor in platform FIB), (Recommended Action: *DEBUG*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RLOGIND-3-ERR_CREATE_EVENTMGR ### Response: (Severity: 3), (Category: IP), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-3-IMDR_ABORT ### Response: (Severity: 3), (Category: FABRIC), (Description: The IngressQ process aborted the iMDR upgrade.), (Recommended Action: Check for error logs from the imdr process to determine the exact cause of the abort. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-EVENT_CONN_DESTROY_FAIL ### Response: (Severity: 6), (Category: ROUTING), (Description: During process termination IS-IS failed to destroy a connection to a service provided by another process. This is an internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-6-HOOPER_LINK_EXCESS_ERR_CLEARED ### Response: (Severity: 6), (Category: PLATFORM), (Description: A link on epm switch had excess errors, but now cleared), (Recommended Action: 'show controllers epm-switch port-mapping location *') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-EA_IM_CAPS_RESYNC_FAILURE ### Response: (Severity: 3), (Category: QOS), (Description: QoS EA encountered an error during resync of QoS capsulations with IM.), (Recommended Action: Try removing the QoS policy on the interface for which this error message is printed from configuration, and then reattach the policy to the interface. 'interface ' 'no service-policy input | output ' 'commit' 'serveice-policy input | output ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATS_FPGA-3-INIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The process failed to initialize. The Process Manager will restart the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_AIS_DEMB ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-PWR_SEQ_MEMORY_FAULT ### Response: (Severity: 4), (Category: DRIVER), (Description: A memory fault condition on indicated power sequencer device has been detected by CCC driver. Due to this fault, the card won't boot and the driver will now take recovery action by reprogramming the device and then power-cycle the card to recover.), (Recommended Action: No action is required as CCC driver is performing auto-recovery of this failure condition.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_APS-6-K1K2_INFO ### Response: (Severity: 6), (Category: L2), (Description: syslog msg to print K1k2 when switchover happens), (Recommended Action: No Action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-4-OOM_STATE_THROTTLE ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show processes msdp detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes msdp detail output, call your Cisco technical support representative and provide the representative with the gathered information. From the job ID obtained from the above command, please run the following command. Copy the error message exactly as it appears on the console or in the system log. Issue the show processes memory command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes memory output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show memory summary command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show memory summary output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: PLATFORM), (Description: The requested operation could not be accomplished because of a low memory condition. This error could impact Linux/Application image download and Launch, Services PLIM IPC (Inter Process Communication) etc.), (Recommended Action: Reduce other system activity to ease memory demands, then restart the process. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-APS_BYTES_SEND ### Response: (Severity: 3), (Category: OS), (Description: APS BYTES SENDING. It is applicable for Digi 20x10g and 2x100g Digi cpak cards.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-3-BAG_REG_ERR ### Response: (Severity: 3), (Category: L2), (Description: L2VPN encountered a problem registering the data containers (bags) for show commands. The text of the message displays the decoded return code.), (Recommended Action: To recover from this state, one may try 'process restart' command. For example, - process restart l2vpn_mgr OR Collect 'show tech sysdb' and 'show tech l2vpn', and contact Cisco TAC support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does IOS XR handle configuration failures during router startup? ### Response: During router startup, if there are configuration failures, IOS XR boots with the last known good configuration instead of the latest changes. This ensures that the system comes up in a consistent state even if recent configuration changes caused issues. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-ISSU_OP_ABORT_STANDBY_REMOVED ### Response: (Severity: 2), (Category: INSTALL), (Description: During ISSU operation, the specified standby node removal was detected by the install ISSU infrastructure and thus the current ISSU operation is aborted.), (Recommended Action: Please check the existence of standby node and retry ISSU. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-3-VOQ_RESET_ERROR ### Response: (Severity: 3), (Category: QOS), (Description: Unable to program one ore more VoQs with the queueing parameters received for a remote interface. The message will provide further details on the error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-7-ERR_LWM_EVENT_BLOCK ### Response: (Severity: 7), (Category: PLATFORM), (Description: Interrupt controller Event Manager event block error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-6-ERR_EVQ_DESTROY ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: During process termination PPPoE MA failed to destroy an event queue. The process will terminate regardless so there should be no lasting problems.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABMGR-1-BAD_XBAR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Persistent failure in serdes links to all connected linecards.), (Recommended Action: Please try powercycling the RSP board using command: 'hw-module loc <> reload'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLARP_LITE_MAIN-3-TRACE_BUFF_INIT ### Response: (Severity: 3), (Category: L2), (Description: 'Trace buffer initialization failed .' 'Tracing will not be functioning properly.' 'Process will proceed running.'), (Recommended Action: 'Process restart can solve this issue.' 'If proplem exists even after process restart,' 'please collect the error log with return value' 'and core dump of the process and contact tac') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-4-SLOT_INSERTION_THRESHOLD_MINOR ### Response: (Severity: 4), (Category: PLATFORM), (Description: Backplane slot connector has card insertions exceed threshold minor per current counter statistics.), (Recommended Action: Give CLI: (admin)# show plugin slot counts location If possible, reduce the frequency of card insertions into this backplane connector. Current insertion counters may be cleared with (admin)# clear plugin slot counts) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-TRISHUL_FPGA_ACCESS_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-6-TYPE6_MK_INPROGRESS ### Response: (Severity: 6), (Category: MGBL), (Description: Masterkey get failed because of Type6 masterkey update still in progress.), (Recommended Action: This is just an information. No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-4-FD_MAJ_LIM ### Response: (Severity: 4), (Category: HA), (Description: A process is potentially leaking FDs. Major limit has been crossed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSA-3-ERR_DEBUG_REGISTER ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric statistics aggregator process encountered an error to register debug facility and hence failed to initialize. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSDIR-4-ABORT_CLEANUP_TIMEOUT ### Response: (Severity: 4), (Category: INSTALL), (Description: Quickstart Director did not recieve a notification from Quickstart Manager indicating abort cleanup was successful. Quickstart Director has made a best effort attempt to clean up any stale system resources and terminate any stale Quickstart Manager processes.), (Recommended Action: The reason for this qs operation failure has to be analyzed. Collect 'show tech-support qs' and forward the logs to the TAC. In addition, 'show tech-support' should be gathered for the process which requested the abort where possible. These logs should also be forwarded to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-LWM_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Failed to execute LWM library functions. In this scenatio OBFL will restart and recover by itself.), (Recommended Action: If the issue is seen even after multiple restart, Please collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-3-FLASH_INIT_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: Optics Driver Initialization failed for fpga flash. Process Manager will restart the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-7-HBLOSS_COLLECT_COMPLETED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Collection of heatbeat loss log has been completed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-MALLOC_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: FIB couldn't allocate memory for some internal processing. It might be in an consistent state.), (Recommended Action: Check memory utilization on the card the error came for and take appropriate steps to reduce it. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT_SWITCH-3-LINK_FAIL_9 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Punt link failed), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure a route policy? ### Response: To configure a route policy in Cisco IOS XR, use the 'route-policy' command in global configuration mode. RP/0/RP0/CPU0:router(config)#route-policy POLICY1 RP/0/RP0/CPU0:router(config-rpl)#if destination in PREFIX_SET1 then pass RP/0/RP0/CPU0:router(config-rpl)#endif RP/0/RP0/CPU0:router(config-rpl)#end-policy <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_EA-2-DPC_CALL_FAILED ### Response: (Severity: 2), (Category: L2), (Description: Internal error. Might occur while distributing data path control to IM), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-FIA2NPU_1_PKT_MINLEN_ERR_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet minimum length error on FIA to NPU-1 interface on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_DYNREG-3-AP_DATA_EXTRACT_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered as data was being extracted for the registration of this attach point. As such, the registration failed and the verification of configuration related to this attach point registration will NOT be performed. Thus, configuration could be accepted but could be unable to be processed by the protocols.), (Recommended Action: Restart the policy_repository process to remedy this situation. If message appears again, please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-S2L_PCALC_FAIL ### Response: (Severity: 5), (Category: ROUTING), (Description: Path calculation failed for the specified tunnel, destination, LSP and path option.), (Recommended Action: The reported path-calculation error may be investigated if desired. This is a solicited message (controlled by logging events lsp-status pcalc-failure configuration).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_LIB-4-RESTART_FAILED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The SVII Adjacency Manager encountered an error while preparing to restart itself. It will restart itself anyway, but there may be other errors.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-4-MONITOR_INTERVAL_ZERO ### Response: (Severity: 4), (Category: DIAG), (Description: Health Monitoring cannot be enabled for the specified test because the interval for the test has been set to 0.), (Recommended Action: If you want the scheduling tests to be removed, do nothing. If you want the scheduled tests to still be run, reconfigure the scheduled tests.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: action-3-TESTMSG ### Response: (Severity: 3), (Category: OS), (Description: This is a test message for ios error message), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-ERR_VRFN_FNS_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: The process failed to initialize the handler functions for verification of changes to its configuration data.), (Recommended Action: Restart of EIGRP might solve the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-6-MAXMETRIC_RUNNING ### Response: (Severity: 6), (Category: ROUTING), (Description: One of the following applies 1. maximum-metric LSA origination setting was changed while the maximum-metric origination was still active. The change will not take effect until the next time the system is restarted. 2. no-abr-off configuration was removed while in max-metric mode. The change will not take effect until the next max-metric event (process restart, migration or reload) is seen. 3. no-abr-off configuration was added while in max-metric mode. ABR-disable mode is exited immediately.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-2-FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fatal internal error occurs, the process will be exited and this will recover automatically by restarting the mbi-hello process by software.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-SERDES_ERROR_LNK1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected a serdes error on link 1.), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. Also, check for any damage to the card and its backplane connectors. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_SYSDB_EDM_REG ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-BRM_BARRIER_SYNCUP_FAILED ### Response: (Severity: 3), (Category: FABRIC), (Description: This may be a transient error seen if fabric components are powered down incorrectly. The system should recover from this error automatically. If the error persists, please contact TAC support.), (Recommended Action: Check Fabric health and look for any disconnects between the fabric stages. Make sure that the fabric planes are up. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-6-MAC_LIMIT_AC_SET ### Response: (Severity: 6), (Category: L2), (Description: Number of MAC addresses in the attachment circuit has reached the configured maximum. If MAC limit action to disable MAC learning and unicast flooding has been configured on the port, then that particular action might have been taken automatically.), (Recommended Action: No particular action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-INVALID_RHDR ### Response: (Severity: 7), (Category: OS), (Description: a function was invoked with invalid rhdr msg), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-6-SOCKET_BUFF ### Response: (Severity: 6), (Category: PLATFORM), (Description: Reading input on scoket from the client. %x- Value of the socket buff at index 0.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_PRM-5-WAIT_FOR_NP_UP ### Response: (Severity: 5), (Category: PLATFORM), (Description: New NP(s) are detected and being brought up. The process is waiting for the NP to complete its bringing up sequence.), (Recommended Action: No action required. Optionally, one can use 'show controller np summary all location <>' command to monitor the NP states.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AIPC-5-EM_DEBUG_INIT_FAIL ### Response: (Severity: 5), (Category: PLATFORM), (Description: Debug initialization failed within EM. Debugs may not be printed), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-BRINGDOWN_REQUEST ### Response: (Severity: 6), (Category: PLATFORM), (Description: The reason should be supplied in the IOS msg itself, but basically this msg means that shelfmgr is shutting down a node because a process specifically requested it.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the command to install an optional package (PIE) in IOS XR? ### Response: To install an optional package, use the `install add` command followed by the package name and location. For example\n```\nRP/0/RP0/CPU0:router# install add disk0:/hfr-mpls-p.pie-3.6.0\n```\nThis command unpacks the PIE and makes it available for activation.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls traffic-eng fast-reroute protect' command in IOS XR? ### Response: The 'mpls traffic-eng fast-reroute protect' command is used to enable MPLS TE Fast Reroute (FRR) protection for a specific interface. When enabled, this interface can be used as a backup tunnel for protecting primary TE tunnels. FRR provides rapid traffic recovery in case of link or node failures by locally repairing the LSPs at the point of failure. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'vrf' command in IOS XR? ### Response: The 'vrf' command is used to configure a Virtual Routing and Forwarding (VRF) instance. VRFs are used in MPLS L3VPNs to maintain separate routing and forwarding tables for each customer. Each VRF has its own set of interfaces, routing protocols, and forwarding policies. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-MTP_MODE_DETECTED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-REG_ACCESS_FAIL_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Register access failure on bridge instance-0.), (Recommended Action: Please reload the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LICENSE-2-ENFORCE_EVAL_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature has been used exceeding the evalution period.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPP_PKT_F1_FULL ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPP packet FIFO 1 full.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCCLASS-3-CONSUMER_ENS ### Response: (Severity: 3), (Category: MGBL), (Description: One or more ENS or NRS APIs has returned a failure. The failure happens while the consumer is calling the ATM VCCLASS client APIs. Internal failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-7-DEBUG_INITFAIL ### Response: (Severity: 7), (Category: SERVICES), (Description: A failure occurred during the initialization of the debug infrastructure.), (Recommended Action: Debug are used to debug cgn_ma in case of functionality issues. This will not impact CGN_MA in any form.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMGR-4-VM_REACTIVATE_WARNING ### Response: (Severity: 4), (Category: OS), (Description: VM activate/deactivate status.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-7-DEBUG ### Response: (Severity: 7), (Category: OS), (Description: --), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_BCM8705-3-OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_NTP-5-STATE_CHANGE_TO_SYNC ### Response: (Severity: 5), (Category: IP), (Description: when the node state change to insync with the ntp server.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_IO-3-OPTION_UPDATE_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The ipv4_io process encountered a software error while creating an entry in the option registry requested by an application), (Recommended Action: IPV4 IO could not update option registry information consistently across all of its instances. This could result in unexpected behavior with respect to some option packets. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-4-LOG_WARNING_OWNER_PLANE ### Response: (Severity: 4), (Category: OS), (Description: A warning owner plane message logged.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-LINK_ANOMALY_CLEAR ### Response: (Severity: 6), (Category: ROUTING), (Description: ISIS was notified that a previous link anomaly condition on the specified interface no longer exists and has reset the per-level link metric to its normal value.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-INVALID_PATH ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_DEBUG ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB was unable to initialize the debugging services. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_CLI-3-INTERNAL_NULL ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP CLI Agent has passed itself a NULL pointer when it should not have done - this point in the code should not have been reached. The HTTP process may need restarting if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-3-FTRUNCATE ### Response: (Severity: 3), (Category: MGBL), (Description: The packet subsystem was not able to initialize memory.), (Recommended Action: The router will not start properly with this condition.\n' 'Call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_FPOE_DB_CORR_ECC_ERROR_LNK4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast FPOE correctable ECC error on link 4), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to terminate a configuration session without committing changes? ### Response: To terminate a configuration session and discard uncommitted changes, use the 'abort' command in configuration mode. RP/0/RSP0/CPU0:router(config)#abort <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ_MGR-7-ERR_LWM_REPLY ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabricq LWM reply error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE0_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE0_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_INACTIVE_AF ### Response: (Severity: 4), (Category: ROUTING), (Description: The specified event was unexpected because the address family is not active on that interface. The operation of IS-IS is not affected by this message and it may safely be ignored. The message is due to an internal programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-4-CLIENTID_ERROR ### Response: (Severity: 4), (Category: OS), (Description: Specified client ID caused an error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-SYSCALL1 ### Response: (Severity: 7), (Category: HA), (Description: A system call failed. The calling function,Line number the failed call, and error are displayed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PREF_COMPR_LIB-6-NOT_APPLICABLE_2T ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: v6 source prefix compression is not required on 2T card.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-4-RAM_ECC_1BIT_THRESH ### Response: (Severity: 4), (Category: PLATFORM), (Description: Threshhold reached for single bit ECC (Corrected) errors.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-CHUNK_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while initializing Queue memory for FGID This may be due to memory availability), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_SSE-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: L2), (Description: BFD Agent has failed to allocate memory for its resources. This would affect proper functioning of BFD Agent.), (Recommended Action: This indicates a low-memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_HFR-5-ERR_SYSDB_INIT ### Response: (Severity: 5), (Category: ROUTING), (Description: The MFWD-HFR library encountered internal error during Sysdb init setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-4-MPA_NP_CLEANUP_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates MPA showdown failed as corresponding NP cleanup failed), (Recommended Action: No action is required for this message. If any issues are observed in subsequent MPA reload, pls copy the error message exactly as it appears on the screen and gather the output of the CLI 'show tech-support ethernet interfaces', 'show qoshal trace location <>', 'show prm server trace init location <>', 'show prm server trace error location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ILITE-3-ASIC_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Some ASIC error has occured and ltrace initialization will fail), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACE_LC-3-ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: ACE Driver Fatal Error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSEC-3-DBG_ERROR ### Response: (Severity: 3), (Category: OS), (Description: An debug init/fractL call failed and error is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-POTENTIAL_DEADLOCK ### Response: (Severity: 4), (Category: ROUTING), (Description: BGP detected the potential for a deadlock to occur. The process will be restarted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-2-ERR_EIO_TRAIN ### Response: (Severity: 2), (Category: FABRIC), (Description: An attempt to train the EIO links to the neighboring Asic have failed. The ingressq driver retries the eio link training. If this error is seen repeatedly, please contact TAC support.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR computational enhancements feature? ### Response: The MPLS TE FRR computational enhancements feature optimizes the calculation of backup tunnels to improve scalability and performance. Techniques include incremental SPF (iSPF), backup path calculation throttling, and the use of a TE backup SPF (BSPF) algorithm. These enhancements reduce CPU overhead and allow FRR to scale to a larger number of protected tunnels. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-6-DDT_BAD_XTR_NONCE ### Response: (Severity: 6), (Category: IP), (Description: 'An xTR issuing LISP Map-Requests includes a nonce value ' 'in each request. The xTR must use a different nonce value ' 'for each Map-Request for a new EID prefix. The identified ' 'xTR has sent us two Map-Requests, each for a different EID ' 'prefix, and they both carried the same nonce value. ' 'When querying the DDT hierarchy, duplicate nonce values ' 'prevent the DDT resolver from associating received ' 'Map-Referral messages with the correct request. To protect ' 'against this problem the DDT resolver has dropped the ' 'second of the two received requests.'), (Recommended Action: 'Contact the operator of the ITR that is issuing ' 'the Map-Requests so that they can fix the problem ' 'by upgrading their system.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_MPLS_EA-3-ERR_INFO_TWO_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in MPLS EA. Typically, this is an error where the software fails to initialize or programming of forwarding feature fails. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef mpls trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_RP_DEBUG-6-REGISTER_FAILED ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MVRP-4-INITIALISATION_FAILURE ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the process. This resulted in the restart of the process.), (Recommended Action: The process will automatically exit and will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP fast external fallover feature? ### Response: By default, if a directly connected eBGP peer goes down, BGP waits until the hold timer expires to tear down the session. The fast external fallover feature immediately resets the session if the interface to the eBGP peer goes down, without waiting for the hold timer. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-REPLACE_COMMIT_PRECHECK_FAILURE ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that install commit as part of the replace operation couldnt be started as failures are seen during the precheck phase.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_TDM-7-REG_MISMATCH ### Response: (Severity: 7), (Category: HA), (Description: An application is trying to register for its table. A table with the same exists, but other attributes have changed, so the table is not allowed to be used.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCM-6-IM_IFTYPE ### Response: (Severity: 6), (Category: L2), (Description: An info regarding the type of interface/VC from interface manager corresponding to the main idb. first %s - Happened at second %d - decimal number for the iftype), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-6-SESSION_STARTUP ### Response: (Severity: 6), (Category: MGBL), (Description: The TTY Session startup found some error. Error is ignored and console will be activated.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_EVM_SEND ### Response: (Severity: 4), (Category: L2), (Description: SSRP failed to send the specified message. The cause may be a resource starvation problem but is most likely to be an internal programming error. The error message should give more details.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart the affected PPP MA process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-2-CE_SWITCH_LINK_STATE_CHANGE_FATAL ### Response: (Severity: 2), (Category: PLATFORM), (Description: The internal link interface for the specified port is down.), (Recommended Action: The board would get reloaded. On reload of board, run following commands from RSP ksh to decode PCDS information - pcds_decode -c NIANTIC <.pcds file>. If users has auto reset option disabled in admin config, then the board would not get reloaded on its own. At this stage collect the output of (admin)'show tech-support control-ethernet location file outputFile') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ET1_INTR_CRC32_CHK_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ET1_INTR_CRC32_CHK_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TRANSPORTTCP-3-DEBUG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to initialize or shutdown the debug module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBMIRROR-6-INFO_RSYNC ### Response: (Severity: 6), (Category: MGBL), (Description: See the man page of rsync for further detail on these errors. Some of these may be fixable/transient, and others might point to a deeper issue.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-3-CRITICAL_ERROR ### Response: (Severity: 3), (Category: L2), (Description: A critical error occurred in OPTICS Driver which involves exiting the process.), (Recommended Action: Power cycle the plim.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-SHIP_PERF_GSP_SEND_FAIL ### Response: (Severity: 7), (Category: SYSDB), (Description: Registering for sysdb_mc gsp send msg size stats failed.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_HW_OFFLOAD-4-CONFIG_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: BFD HW offload not supported on this node, disabled it), (Recommended Action: Execute 'no hw-module bfd-hw-offload enable loc <>' to remove the config for config consistency) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-2-CPLD_POWER_CTRL_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: The Fabric PLD power fault alarm was encountered), (Recommended Action: A power fault has occurred.If the fault has occurred, node will be shutdown. Please collect logs mentioned in required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ILITE-3-POWERUP_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Power up has failed, this may be a program level error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-EEPROM_READ_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: The read of the eeprom to fetch card_type for the given node has failed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZEN-3-INIT_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: The board might have bad flash part that need to be replaced), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_ENA-3-EMWEB ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP ENA filesystem handler was unable to carry out an EmWeb server function. The HTTP process may no longer be able to function correctly, and may need restarting if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-BIOS_FATAL_EVENT ### Response: (Severity: 3), (Category: DRIVER), (Description: BIOS has reported a fatal event.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISLM-4-ACCT_STOP_REC_FILE_WRITE_FAILED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This syslog is printed when acct stop rec write to file failed.), (Recommended Action: Check the harddisk space. Try disable and then enabling the accounting stop storage feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMS-7-REQUEST_REG_SEND_ERR ### Response: (Severity: 7), (Category: SYSDB), (Description: The SysDB server is unable to function due to a problem with a piece of infrastructure. The only hope of recovery is to restart. If the problem persists, the card will be automatically reloaded.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IPV4_EA-3-FAILURE3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an failure message in the ASR9K platform specific code software to indicate anomolies that are not serious FAILURE. This Failure is most likely caused by a temporary situation, so is unlikely to re-occur.), (Recommended Action: Please collect console log, traces * SH_CMD show af-ea ipv4 trace errors loc * Also notice if the failure message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SGT_FIFO_OFLOW_1_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress sgt fifo overflow on xaui-1 bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-EMPTY_SERIAL_BOOT_OVERRIDE ### Response: (Severity: 4), (Category: PLATFORM), (Description: This informational message informs the user that the Shelfmgr discovered an empty serial number due to an older ROMMON format, but it will allow the RP to boot because the operator had configured to override the restriction of disallow booting a RP with empty serial number.), (Recommended Action: Please upgrade the booting RP to the latest recommended ROMMON.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-2-SDK_INCOMPATIBLE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Current SDK and Morgoth version is incompatible. Please upgrade/downgrade Morgoth to the sdk compatible version or use sdk image which is compatible with the running Morgoth version.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-LM_DRAIN_QUEUE_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: Unable to drain all the cells from a given queue. This may cause barrier timeouts once the queue is re-enabled. Hard resetting Asic'), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-4-MPLS_ENCAP_OOR ### Response: (Severity: 4), (Category: ROUTING), (Description: In lspnh create/update, adding path encap failed due to ENCAP Table OOR .), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_MPLS-3-ERROR ### Response: (Severity: 3), (Category: L2), (Description: Platform MPLS FIB, error), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace [common|mpls] all loc <>). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_400G_POD-3-SPUR_INTR ### Response: (Severity: 3), (Category: FABRIC), (Description: An interrupt is generated but the interrupt status register indicates no pending interrupts. This may be due to a hardware error where the interrupt line is stuck in its active state i.e. active low.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_BASE_NAME ### Response: (Severity: 3), (Category: OS), (Description: The name could not be used.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-3-UNEXP_PULSE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A pulse was received by SPP from the OS or another process, but no handler was registered to take appropriate action. This indicates a problem with SPP if the pulse was received from the OS, or another process which sent the unexpected pulse.), (Recommended Action: Restarting the process may help to resynchronize the system state. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-6-ACTIVE ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message reporting that a link has entered or left Active state as part of a bundle interface. The link configuration may have just been changed or there may be an operational reason for the event such as a state change or LACP protocol update.), (Recommended Action: Nothing, this is not an error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key properties of Cisco IOS XR software components? ### Response: Cisco IOS XR software components exhibit the following properties\n- Functionality that can be individually developed, released, and upgraded on running systems without affecting other software components\n- Executable code for running a process or libraries that are shared between different processes\n- Well-identified functionality (e.g., ipv4-bgp, ipv4-acl, ipv4-mrib components)\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IXDB-4-RECOVERY ### Response: (Severity: 4), (Category: SYSDB), (Description: The low level ixdb database has recovered after a process restart. Upper layers must recover from a potentially incomplete bulk operation as well as any application data inconsistency within ixdb. Ixdb only recovers its own state.), (Recommended Action: NONE. The router will attempt to recover automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-4-DISK_ALARM ### Response: (Severity: 4), (Category: HA), (Description: Set: When some monitored disk's usage is above 80%. Cleared: When all monitored disks' usage are below 80%.), (Recommended Action: The indicated disk device may be running out of space. Determine if there are unneeded files on the disk.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-1-MC_HI_OVR_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Multicast high priority fifo overflow error), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-INIT_FAILURE ### Response: (Severity: 3), (Category: DRIVER), (Description: CARD_MGR Driver Initialization failed. Process Manager will restart the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-XIF_RQFF_MEM_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected XIF RQFF memory multi-bit error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-FAULT_NOTIFICATION ### Response: (Severity: 3), (Category: L2), (Description: An error was encountered when trying to generate a fault notification for a local MEP, as a result of a defect detected from a peer MEP. This will mean that the corresponding SNMP trap will not be raised. If the error persists, CFM may not operate correctly.), (Recommended Action: If the error persists, it may be cleared by restarting the cfmd process on the node where the error is occurring.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_APS-4-WP_INFO ### Response: (Severity: 4), (Category: L2), (Description: State change in the APS group internal communication system detected. Expected during transitory conditions at config changes, OIR, etc. The message contains info about the WP communication components affected.), (Recommended Action: Verify continued correct operation of SONET APS.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TYPE6-3-EVENT_MANAGER_FAILURE ### Response: (Severity: 3), (Category: SECURITY), (Description: Event manager could fail if system resources (eg: memory) is not sufficiently available for use.), (Recommended Action: If it is related to process-level resources, restarting the type6 server process (type6_server) using the command 'process restart type6_server' might solve the issue. For further detail contact the Cisco technical support representative with the gathered information and the exact error message as it appears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAW_LIB-4-FAIL_ERASE_RBT_HIST ### Response: (Severity: 4), (Category: MEDIA), (Description: Failed when erasing the corrupted reboot info.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-FM_ADD_IFH2GRP ### Response: (Severity: 3), (Category: OS), (Description: An internal fm add ifh to group function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKS_SERVER-6-INFO_GENERAL ### Response: (Severity: 6), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE_ERR_5_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE_ERR_5 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. This condition could occur due to broken pins/components/clock or ASIC init errors (either NPU or FIA init errors). If hardware is inspected to be clean and no physical damage, environmental factors like temperature might be factor for this error. Wait and check if errors get resolved. If errors are consistent, take actions like checking temperature of the box, if high address it. Check for any initialization errors.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSDIR-1-OPERATION_QS_PREP_DONE ### Response: (Severity: 1), (Category: INSTALL), (Description: The Quickstart prepare operation has completed successfully.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-SYSMGR_REGN ### Response: (Severity: 3), (Category: OS), (Description: Unable to register with sysmgr.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support sysmgr command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support sysmgr output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-7-ERR_EVM_NOTIFY ### Response: (Severity: 7), (Category: PLATFORM), (Description: Interrupt controller Event Manager notify error), (Recommended Action: Please attempt to correct the error by restarting the process. Issue the command in exec mode -process restart longbeach If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MMAP_PEER-7-DEBUG ### Response: (Severity: 7), (Category: OS), (Description: For debug only.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR_ENCAP-3-INIT_SYSDB_REG_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Process failed to register for SysDB verification while applying encapsulation config. This could be due to the invalid arguments or memory allocation failure for which there is no current handling, therefore system may now be out of sync.), (Recommended Action: Repeat failed configuration command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-BOGUS_LINKPOINT ### Response: (Severity: 3), (Category: MGBL), (Description: 'Bogus link point'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKPLATFORM-6-SENDFAIL ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The platform driver was not able to send data to the packet manager. This could happen when the platform driver is trying to send the initilization information to the packet manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_LQ_OFLOW_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue overflow error on XAUI 0 LQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-QCR_MEM0_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected QCR MEM0 Error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-UNSUPP_TX_NON_CH ### Response: (Severity: 3), (Category: FABRIC), (Description: The Tx POD detects an unknown error on a pod. The pod might not be functioning properly, and can cause cell drops, or corruption from received cells. There can also be a software bug such that the error is not handled), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-2-SYSMGR_REGISTER ### Response: (Severity: 2), (Category: HA), (Description: API for registering node state change with sysmgr failed. This change will be registered later.No impact on running of process.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-6-NO_POWER_SFPPLUS ### Response: (Severity: 6), (Category: L2), (Description: There is not enough available power on the PLIM to power on the SFPPLUS.), (Recommended Action: Remove the SFPPLUS from the given port.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LOW_VOLTAGE_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP voltage less than or equal to the low voltage warning threshold. The CFP is the pluggable optics on the line cards. The voltage threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check the 'show environment voltages'. If the system voltage is normal then replace the optics with working one (if any). If the system voltage is not normal, then make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP_GMP-4-WARN_EVENT ### Response: (Severity: 4), (Category: IP), (Description: An error occured while the ARP GMP was waiting for events. In this situation the process will terminates and restarts.), (Recommended Action: In this case the process would restart and will recover by itself. If the issue is seen repeatedly Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-3-MOD_INIT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Module Init failure due to faulty optics.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - show tech-support ethernet interface location <> - show controller <> phy - show controller <> internal) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NCD-3-PAK_CSUM_MISMATCH ### Response: (Severity: 3), (Category: OS), (Description: A checksum error was detected for a packet by NCD.), (Recommended Action: The clients of NCD will attempt to recover from this situation by retransmitting the packets. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise, take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-6-SWITCH_FDB_FLUSH_WHILE_AUQ_FULL_TRIGG_WA_SUCCESS ### Response: (Severity: 6), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process issued a FDB flush operation while the AUQ was full. When this occurs a secondary AUQ is enabled to avoid FDB flush operation failure.), (Recommended Action: No action is required from the operator. This is informational message only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLUTLU-4-MIPC_NOTIFY ### Response: (Severity: 4), (Category: PLATFORM), (Description: TLU received notification from MIPC due to unrecoverable error or invalid address. client downloads the entire table to hardware as a recovery mechanism. This is an informational message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_SERVICE_EA-3-ERR_PRM_INIT ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to set up connection with PRM server process.), (Recommended Action: When this issue happens, it will trigger an automatic restart. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-4-INVALID_PORT ### Response: (Severity: 4), (Category: DIAG), (Description: A diagnostic request is being made on a port that does not exist.), (Recommended Action: Ensure the specified port number exists and that the correct port number is being specified.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBINST_DEBUG-4-INTERNAL ### Response: (Severity: 4), (Category: INSTALL), (Description: The Install infrastructure has reached an unexpected state. Operations will continue, but the logging and debugging capabilities of the Install infrastructure may not function as expected.), (Recommended Action: It only impacts logging and debugging and has no impact on the functionality of the system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV6-3-ERR_INFO_VERBOSE ### Response: (Severity: 3), (Category: L2), (Description: A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code and a string interpretation of the error code. It provides more verbose information. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef trace location <> show cef platform trace common all location <> show cef platform trace ipv6 all location <> show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-6-TIMEOUT_IGNORED ### Response: (Severity: 6), (Category: SECURITY), (Description: An internal software error occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-SRMS_LOOKUP_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: SRMS lookup to get the prefix sid for bgp prefix failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-3-ERR_GENERAL ### Response: (Severity: 3), (Category: SECURITY), (Description: SSH encounterd some error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-2-NOMEMORY ### Response: (Severity: 2), (Category: ROUTING), (Description: The requested operation could not be accomplished because of a low memory condition.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_LONG_PKT_0_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress long packet detected on xaui-0 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-BFD_BIND_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to connect to the BFD server. The connection will be retried.), (Recommended Action: This failure may be due to lack of resources. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-INTERNAL_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: A non-fatal fault occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-THREAD_PRIV_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE-7-DEBUG ### Response: (Severity: 7), (Category: OS), (Description: Internal debugging message.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-NOSPACE ### Response: (Severity: 3), (Category: MEDIA), (Description: nvram full), (Recommended Action: Delete unwanted files) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-CONNECT_GSP_FAILED ### Response: (Severity: 3), (Category: OS), (Description: 'Connection to GSP failed.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GDOI-7-VERIFY_APPLY ### Response: (Severity: 7), (Category: OS), (Description: A sysdb verify/apply callback information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_IPV6_EA-3-ERROR1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Typically, this is an error where the software fails to initialize or programming of forwarding feature fails. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show cef ipv6 location <> show cef ipv6 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-4-DEV_LATCH ### Response: (Severity: 4), (Category: PLATFORM), (Description: Errors seen on the device bus. A reason text will be supplied.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-RADIUS_USER_AUTHEN_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: AAA user authentication faild.), (Recommended Action: 'Make sure you use the correct username and password, otherwise contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. with the exact log message received') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the command to enable OSPFv2 on Cisco IOS XR? ### Response: To enable OSPFv2 on Cisco IOS XR, use the command 'router ospf ' in global configuration mode. The process name is a unique alphanumeric string identifying the OSPF routing process. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LWMESS-7-CORRUPT_CLI ### Response: (Severity: 7), (Category: OS), (Description: A corrupt memory area was discovered in an internal data structure), (Recommended Action: This is an internal error and should be reported to TAC. Take a memory dump and try re-starting the offending application.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVM-4-FATTACH ### Response: (Severity: 4), (Category: OS), (Description: An ionotify call to request file-state notification failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. This is an internal error and should be reported to TAC. The server process for the failed fd has died or there is a connectivity failure. If it can be determined which server failed, it and the application with the ionotify error should be restarted. If that fails, the router should be rebooted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GE_DMAC-6-UPDN ### Response: (Severity: 6), (Category: PLATFORM), (Description: A link in the RSP control plane MAC has change state.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers ge-dmac device detail location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers ge-dmac device detail location output, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you discard unsaved configuration changes in IOS XR? ### Response: To discard unsaved configuration changes in IOS XR, you can use one of the following methods: (1) exit configuration mode using 'end' or 'exit' commands, (2) use the 'abort' command to discard changes and release the configuration lock, or (3) use the 'clear' command to reset the configuration session. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAGT_SERVER-4-EN_ACCURACY_UNSUPPORTED ### Response: (Severity: 4), (Category: PLATFORM), (Description: The system timing has switched to enhanced accuracy mode as a result of applying the 'timing-accuracy enhanced' configuration. This line card does not have hardware support for enhanced accuracy mode and the timing behaviour of line card will be undefined if the system continues in this mode.), (Recommended Action: Replace the line cards in the message with the ones that support enhanced timing accuracy, or remove the 'timing-accuracy enhanced' configuration and reload the router for changes to take effect.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-INIT_ERR_STR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during initialization, causing the process to terminate.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_PR_INTR_PR_BA_PROTOCOL_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_PR_INTR_PR_BA_PROTOCOL_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_RDLOCK ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-3-NOMEMORY ### Response: (Severity: 3), (Category: INSTALL), (Description: The requested operation could not be accomplished because of a low memory condition.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-1-ERR_BOARD_FAULT ### Response: (Severity: 1), (Category: FABRIC), (Description: Fabric board is not operational due to the indicated fault. This information is extracted from the fabric PLD registers.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE tunnel selection metric feature? ### Response: The MPLS TE tunnel selection metric feature allows the configuration of the metric type to be used for tunnel path calculation and selection. The default is to use the TE metric which is carried in TE LSAs. Alternatively, the IGP metric can be used which is the normal OSPF or IS-IS metric. This provides flexibility in optimizing tunnel paths. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: adminexec-3-LTRACE_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: Initialization of trace functionality for exec shell failed. This would affect the debugging of exec shell.), (Recommended Action: Try logging out and login again. If the message appears again, copy and save the message. Collect show logging output and any other suspicious error messages on console and inform technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-4-QFP_FAILURE_SPA_BRIDGE_REMOVAL ### Response: (Severity: 4), (Category: L2), (Description: Failed to remove a SPA bridge controller), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers QFPCPUBridge trace <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers QFPCPUBridge trace <> output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-TX_UNF_ERR_FIA01 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA01 Tx underflow error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-4-DEPRECATED ### Response: (Severity: 4), (Category: IP), (Description: 'LISP will be discontinued in IOS-XR.'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LMRIB_API-3-GEN_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Error occurred in lmrib client lib.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_ACCESS_ALARM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ct_agent-3-ERR_MALLOC ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error. System is out of memory - malloc failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-5-TIMEOUT_EXIT ### Response: (Severity: 5), (Category: HA), (Description: A process with an event manager that was not sending heartbeats has exited.), (Recommended Action: The debugging information collected when the event manager stopped sending heartbeats should be examined and provided to technical support for analysis.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-0-LC_NP_LOOPBACK_FAILED ### Response: (Severity: 0), (Category: PLATFORM), (Description: This line card has detected a problem with the packet punt and injection path between this line card CPU and some network processor(s), and the consecutive failure count has reached or crossed the failure threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REPLICATOR-7-SEND_FAILED ### Response: (Severity: 7), (Category: LIBRARY), (Description: An error was returned from RDS when trying to send an update. Clients will handle this condition differently either by retrying later, or failing the operation. If this condition persists, data may be lost on failover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NFEA_PAL-1-FLOWEXP_LIMIT ### Response: (Severity: 1), (Category: PLATFORM), (Description: The number of flow exporter support in hardware is limited. The config has resulted in exceeding this limit.), (Recommended Action: Remove the configured exporter from the flow monitor.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_10_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-BAD_SEQNO ### Response: (Severity: 7), (Category: HA), (Description: The mirroring request had an incorrect sequence number. This indicates either an algorithm error, or data corruption on the active node or in the data transfer between nodes. Initial Data Transfer will be redone, and no data loss should occur.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-2-CRS8_B_FANTRAY_MISMATCH ### Response: (Severity: 2), (Category: PLATFORM), (Description: The CRS-8-LCC-B chassis is runing with different types of fan trays. Please check the fan tray and make sure both are of same type.), (Recommended Action: Please check the fan tray type and make sure both are CRS-8-FANTRAY-B Fan Tray if fan tray mismatch is detected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-7-NULLCHUNK ### Response: (Severity: 7), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-0-CHASSIS_SHUTDOWN ### Response: (Severity: 0), (Category: PLATFORM), (Description: Chassis is shutting down due to reason mentioned.), (Recommended Action: Examine chassis based on above message. If chassis shutdown is due to low voltage on both power shelves, then please examine the battery and replace if necessary. Note that in all cases of shutdown, the chassis needs to be manually power cycled, or the RPs physically OIR'd so as to boot the chassis again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET_LOOPBACK-3-UIDB_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize UIDB connection in the platform Ethernet loopback component), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_SW-3-ERR_PROTO_INIT ### Response: (Severity: 3), (Category: IP), (Description: IPv6 Protocol failed to intialize the netio datapath.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-POLICYCONFIG ### Response: (Severity: 4), (Category: ROUTING), (Description: A problem was encountered while setting up route policy configuration. Some of the routing policy may not have been configured correctly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-BADAREA ### Response: (Severity: 4), (Category: ROUTING), (Description: The system received an OSPFv3 packet with an area ID that does not match the area that the interface belongs to.), (Recommended Action: Check the OSPFv3 configuration of the receiver and the sender for inconsistency. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XBAR_ERR-3-ERR_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Crossbar driver encountered an Error in operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-PULSEQ_STATE_CHANGE ### Response: (Severity: 6), (Category: HA), (Description: This message is emitted when system pulseQ state switches between Normal/Minor/Severe/Critical states), (Recommended Action: If system changed to severe/critical alarm should be generated.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_BAT_FAL_B ### Response: (Severity: 2), (Category: PLATFORM), (Description: The CPT 50 Shelf Battery Failure B alarm occurs when battery B is down or not detected. This could be because the battery is removed or is not operational.), (Recommended Action: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-4-AVLBL_MTU_MISMATCH ### Response: (Severity: 4), (Category: IP), (Description: Minimum IPv4 MTU must be 68 bytes. Available link MTU is below the minimum IPv4 link MTU (68). IPv4 may not work correctly on this interface.'), (Recommended Action: Adjust the lower layer mtu such that atleast 68 bytes is available to IPv4. If the lower layer mtu is big enough collect the output of show tech-support, show ipv4 ma trace, show im trace, show im chains, show ipv4 interface for the interface for which the above error is seen. Try unconfiguring/reconfiguring the interface if the lower layer mtu is big enough and still the error is seen.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GT_ETH_MGMT-3-NETIO_EVM_CREATION_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error detected when creating the netio event manager. process will restart automatically to recover from this error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-4-TYPE6_MASTER_KEY_UPDATE ### Response: (Severity: 4), (Category: SECURITY), (Description: radius configs are migrating due to change in the Type6 Master key. radius configs will not work during this migration.), (Recommended Action: This is just a warning message and No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-IGPTE ### Response: (Severity: 3), (Category: ROUTING), (Description: Error encountered while attempting to use the IGP_TE Library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospf - show ospf trace all - show running-config) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-NPU_1_TS_UPDATE_ERR_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Timestamp update error on NPU-1 interface on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-IMG_LAUNCH_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in launching Linux/Application image. Cause of the error will be mentioned in the message displayed. This error prevents Services PLIM from coming up to its full functional Active state.), (Recommended Action: Do cold reboot of Services PLIM MSC If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_IPC-3-OPERATION_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The message indicates failure in any of the process initialisation like installing or downloading the image gets failed, failed to allocate memory or any failure in service engine.), (Recommended Action: Please collect the console log and CLI output. Copy the error message exactly as it appears on the console or in the system log. Issue the cmd command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the cmd output, call your Cisco technical support representative and provide the representative with the gathered information. show cef show cef location <> show cef trace location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL_SIP700-3-TRACE_INIT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The CPU Control driver failed to initialize the LTrace facility. The effect is that the CPU Control driver debug trace facility is not functional. This means that trace information used by Cisco support to help isolate CPU Control device issues may not be available. This does not impact normal CPU Control device operations. Note that it is unlikely that this failure would occur by itself. This failure is generally indicative of a larger LC-wide problem.), (Recommended Action: This error is unlikely to occur by itself nor is it likely to be the root cause of the problem. Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers CPUCtrl ltrace location <>/<>/CPU0 command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers CPUCtrl ltrace location <>/<>/CPU0 output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_SOCK-3-ERR_SYSMGR ### Response: (Severity: 3), (Category: L2), (Description: The process was initialized successfully but was unable to inform System Manager of the success.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-PROC_CNT_MINOR ### Response: (Severity: 3), (Category: HA), (Description: When number of processes has crossed above MINOR Threshold Percentage.), (Recommended Action: The number of processes running has increased. Determine if there are any unnecessary processes available in dir '/var/log/debug_proc_cnt' and kill them by using kill -9 .) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM-3-CFLCT_NOT_FOUND ### Response: (Severity: 3), (Category: IP), (Description: An IP info structure with conflict flag set is not found in the conflict database. This is an error condition indicating IP ARM database has erroneous information. This can cause some unexpected behavior relating to the ip address not found in the database.), (Recommended Action: Collect the output of show tech-support, show arm [ipv4/ipv6] trace and the steps that lead to this behavior.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_CLEAR_TABLE ### Response: (Severity: 3), (Category: ROUTING), (Description: There was an error re-installing routes in the RIB after receiving a 'clear table' event.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-CONFIG_DOWNLOAD_FAILED ### Response: (Severity: 6), (Category: SERVICES), (Description: 'Failed to download the config file to the Running config'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-3-MAXIM_ALARM_RAISED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Power Sequencer failed alarm indication received from CBC. This may be a serious failure however process may continue functioning if failure was transcient.), (Recommended Action: Provide the following CLI: (admin)# show env Use the pid from canb-server output to look for matching pid in the pfm output. If the alarm indication does not clear within 30 minutes, contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HPI-3-UNEXPECTED_VM_ADDR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PDMA expected mmap_dma_memory to low address, but got high address.), (Recommended Action: Check the memory usage of the process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_MPLS_EA-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in MPLS EA. Typically, this is an error where the software fails to initialize or programming of forwarding feature fails. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef mpls trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEAT_MGR-3-DENY_IN_ACL_NOT_SUPPORTED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Deny' action for an ACE is not supported and will be ignored. The behavior will be the same as with Permit action.), (Recommended Action: If the behavior is not acceptable, remove the Qos policy from the interface, otherwise no further action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-TLC_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred in MRIB TLC operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-1-UPGD_SKIP ### Response: (Severity: 1), (Category: DRIVER), (Description: card_mgr has detected on this PID the running BB IOFPGA version on the box is not, compatible with the CPU-IOFPGA. Hence it is recommended to upgrade BB-IOFPGA first before going for CPU-IOFPGA upgrade in order to avoid bricking of te box.), (Recommended Action: In case the operation fails please collect logs 1. Syslogs 2. show tech card-mgr 3. show tech fpd 4. show tech obfl 5. show tech shelf-mgr 6. show tech ctrace 7. show tech fpd-serv) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_ENS_LIB ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA driver ENS client library initialization error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-4-PKGFS_INIT_BOOT ### Response: (Severity: 4), (Category: INSTALL), (Description: Could not update the package file system's list of active files.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-CLOCK_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected a clock failure on some bus/port), (Recommended Action: Please check the source of the external syncE clock. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-TX_BRST_SHRT_ERR_FIA11 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA11 Tx burst short error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-3-MACSEC_MODE_CFG_CHANGED ### Response: (Severity: 3), (Category: L2), (Description: 1. If the hw-module command is used to configure the user defined configs, there will be inconsistency between the user config and the hardware. Since the driver in line card has already started the phy initalization process before this config is received. Needs attention with chassis line card reload.), (Recommended Action: System NODE is inconsistent. Need to reload the NODE for new values to take effect. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_6_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_LMI-3-IM_ERR ### Response: (Severity: 3), (Category: L2), (Description: Error in interface manager operation. Ex: Connection to Interface Manager not getting established, or some IM API errored out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTR1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM_COMMON-3-BAD_CLASSIC_CONFIG_COMPRESS ### Response: (Severity: 3), (Category: MEDIA), (Description: Decompress of Compressed Classic Config Failed), (Recommended Action: If need to use classic configs, boot an appropriate classic image and rewrite the config. If not No action is required..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can a default route be originated in BGP? ### Response: A default route can be originated in BGP in two ways\n1) Using the default-information originate command, which will originate a default if one exists in the routing table.\n2) Using the neighbor default-originate command, which will originate a default to a specific neighbor unconditionally.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV_AGENT-3-ERROR_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The process exited due to the reason mentioned in the message.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-PMBUS_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PMBus Failure/Success while accessing device), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPP_TO_DDR_PAR_ERR ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPP to Tx DDR FIFO parity error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-MEM_ALIGN ### Response: (Severity: 4), (Category: OS), (Description: Core dump failed because the pending segment flush failed.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-3-IM_CAPS_RESYNC_FAILURE ### Response: (Severity: 3), (Category: QOS), (Description: QoS EA encountered an error during resync of QoS capsulations with IM.), (Recommended Action: Try removing the QoS policy on the interface for which this error message is printed from configuration, and then re-attach the policy to the interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MGID_OOR-4-MGID_COUNT_OOR_ABOVE ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-5-PEC_REMOVED ### Response: (Severity: 5), (Category: PLATFORM), (Description: The expansion card was removed with serial number.), (Recommended Action: None, informational purpose only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Configuration File System (CFS) in IOS XR? ### Response: The Configuration File System (CFS) in IOS XR is a virtual file system that stores the running configuration, committed configurations, rollback points, and configuration templates. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_SIM-7-BAD_NVRAM_VAR ### Response: (Severity: 7), (Category: MEDIA), (Description: Could not allocate memory for a DRAM buffer), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-3-STATUS_UNKNOWN ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: bfm encountered an error and is not able to recover from the error. A reason text will be supplied call support with this text. An integer errno will also be printed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Informational Topaz LC Kensho-GL CPU Subsystem DLL message.), (Recommended Action: Nothing. Reporting normal progress of Topaz LC Kensho-GL CPU Subsystem DLL.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_CHANNEL_DOWN ### Response: (Severity: 3), (Category: FABRIC), (Description: Every qlink RX channel is connected to one fabricqrx link. Down channel will also bring-down corresponding fabricqrx link. This qlink channel has hit errors but it cannot be reset as it drives clock to that qlink. Resetting this channel will reset the clock also, so all other links in this qlink will go-down which in-turn will cause the fabric plane to flap.), (Recommended Action: Do graceful recovery by card reload or shut and unshut of plane correspond to down link.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBCORE-3-NOMEM ### Response: (Severity: 3), (Category: SNMP), (Description: The system might be running low on memory and adequate amount of memory was not available to complete the request), (Recommended Action: If this message is persistent, check memory usage Try to have sufficent memory conditions) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-4-SYSDB_BIND_CONN_IN_USE ### Response: (Severity: 4), (Category: SYSDB), (Description: The caller of sysdb_bind() API in the traceback passed the connection variable that is already in use.This is a defect in the code which might lead to memory corruption or crashes at times.The caller of sysdb_bind API should fix their code.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_INFRA-3-DIAGS_INIT_FAILURE ### Response: (Severity: 3), (Category: INSTALL), (Description: A failure occurred attempting to initialize ISSU diagnostics. The relevant process will restart and attempt to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cds_svr-3-INTERNAL ### Response: (Severity: 3), (Category: OS), (Description: The server has either failed a function that expected to succeed, or has got into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_MEM_FAIL_1 ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LACP_LITE-3-ERR_SHMEM_UNAVAILABLE ### Response: (Severity: 3), (Category: L2), (Description: BM-Local has requested transfer of more interface records than shared memory can accommodate), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_SERVER-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: L2), (Description: ASIC scan server has failed to create the event manager. This would result in the automatic restart of the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_10 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-6-SHMWIN_RESET ### Response: (Severity: 6), (Category: L2), (Description: The CFM shared memory window is being reset. All shared memory data will be lost. This means that all per-interface, per-MEP and per-peer-MEP counters are reset to zero.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-BPM_PARENT_ENT_DOUBLE_DELETE ### Response: (Severity: 3), (Category: ROUTING), (Description: Received a double delete for the removal of parent bpm entity on the child bpm entity.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure LDP maximum PDU length? ### Response: To configure the maximum PDU length for LDP, use the 'max-pdu-length' command under the MPLS LDP configuration. RP/0/RSP0/CPU0:router(config)#mpls ldp RP/0/RSP0/CPU0:router(config-ldp)#max-pdu-length 1500 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-4-SCRIPT_WARNING ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: An internal syntax error was detected in the script file. The current line was skipped and the execution of the script continued.), (Recommended Action: Check the script for the skipped or ignored line. Make syntax changes as needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-3-MALLOC_FAILED ### Response: (Severity: 3), (Category: OS), (Description: Malloc failed for ssm process. Check if node is in low memory condition.), (Recommended Action: Collect show tech ssm. Collect show memory summary location , show process memory location ie. for node where error is seen 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-3-BAD_LISTENER_TAG ### Response: (Severity: 3), (Category: OS), (Description: Packet is received with unknown listener tag, hence dropping it.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SESVI_NETIO-3-INIT_TRACE ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of tracing for the NetIO caps. This will cause the capsulation to be unloaded, and an error returned to the user.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-4-PCIE_FATAL_AER ### Response: (Severity: 4), (Category: INFRA), (Description: A fatal PCIe error was reported to the Ethernet Switch Driver by the hardware on one of the PCIe links between the Ethernet switch and its upstream PCIe bridge.), (Recommended Action: No action is required from the operator. The Ethernet Switch Driver initiates a reset recovery sequence to reinitialize the Ethernet Switch hardware to a functional state.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOSHAL-6-QOS_MODE_CHANGE ### Response: (Severity: 6), (Category: PLATFORM), (Description: 'Any change in qos mode requires the LC to be rebooted to take effect.'), (Recommended Action: hw-module location reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-PHY_ACCESS_PERSIST ### Response: (Severity: 3), (Category: L2), (Description: Software could not access the PHY device during port initialization.), (Recommended Action: The physical port has been disabled and cannot be used. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-6-STARTUP_ALTERNATE ### Response: (Severity: 6), (Category: MGBL), (Description: Configuration Manager is displaying a message during boot time to indicate an alternate configuration will be restored during the router boot operation. The alternate configuration is specified by the user by using a boot option or ROMMON variable setting.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-6-ENTRY_NOT_EXIST_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Attempt to delete NP entry that does not exist.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERROR_OPER ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, operational error information), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>), 'show install active', 'show logging console', 'show platform' and 'show version'. Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TPA_KEYS-3-TPAKEY_LTRACE_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Unable to start third party gpg key ltrace.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ERR_SYSDB_LIST ### Response: (Severity: 3), (Category: MGBL), (Description: 'The sysdb operation failed. Error text is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PVSTAG-4-SEND_FAIL ### Response: (Severity: 4), (Category: L2), (Description: A failure has repeatedly occurred when attempting to send PVST+ or PVRST BPDUs. This could result in incorrect protocol behaviour, or in the worst case, forwarding loops. The failure is most likely caused by a lack of available memory or packet buffers on the affected line card.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFL-3-ERROR_RC ### Response: (Severity: 3), (Category: PLATFORM), (Description: An function has failed in the OBFL process. The details are supplied in the msg.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPCP_SRVR-6-IPCP_SERVER_RESTARTED_NODE_REBOOTING ### Response: (Severity: 6), (Category: PLATFORM), (Description: IPCP server has been restarted. The node will be reloaded. This is not an error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_BIND_NOTFOUND ### Response: (Severity: 4), (Category: SYSDB), (Description: The user bound to a node which does not exist. This is a warning only - this action is perfectly legal.), (Recommended Action: Check that this is the directory you intended to bind to.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-FALLBACK_CHOICE ### Response: (Severity: 6), (Category: OS), (Description: It is an informational message.), (Recommended Action: It is an informational message. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_VPLS-7-DEBUG_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB VPLS component.), (Recommended Action: *NONE* Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-6-SEND_PULSE_FAIL ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failure to send pulse to shelfmgr to notify the particular alarm condition.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSA-3-ERR_BAG_REG ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric statistics aggregator process encountered an error to register the bag to bag infrastructure that is useful for packaging up complex data into single SysDB items. This software error will cause process termination for recovery The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-PCI_ATTACH_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: The PCI attach has failed due to the above mentioned reason.), (Recommended Action: Collect all the event logs and the output of the following commands executed from the CLI of the active RP: 1. 'show process fia_drvr location ' 2. 'show controllers fia trace all location ' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-3-ERR_INV_FGID ### Response: (Severity: 3), (Category: FABRIC), (Description: Trying to add an out of range FGID to an array.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_HEAP-7-DATA_CORRUPTION ### Response: (Severity: 7), (Category: HA), (Description: Data corruption is detected in CDM data structures. This will generally result in a single process failure.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-THREAD_CREATE_FAILED ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: Packet server was unable to create the specified thread.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp bestpath med missing-as-worst' command in IOS XR BGP configuration? ### Response: The 'bgp bestpath med missing-as-worst' command is used to treat routes without a MED attribute as having the highest possible MED value for best path selection. By default, if a route is missing the MED attribute, it is treated as having a MED of 0, making it the most preferred route. This command changes the behavior to make routes without a MED the least preferred. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-0-PEX_VS1_FATAL_ERR_BIT ### Response: (Severity: 0), (Category: PLATFORM), (Description: Device driver detected a pex switch error), (Recommended Action: Please try to correct problem by reloading board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPA_1P_OC192-3-GENERIC_ERROR ### Response: (Severity: 3), (Category: L2), (Description: SPA OC192 driver error messages), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-2-NODE_RELOADING ### Response: (Severity: 2), (Category: MEDIA), (Description: The media storage device specified is the boot device and is unavailable. The software will not be able to continue functioning without the boot device so the node is reset to failover or recover the failed device.), (Recommended Action: Media storage data should be recovered from either active node or current primary mirroring device. If media device still fails, replace media device. If not redundant node or no mirroring then reinstall software and configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APPMGR-2-DOCKER_DAEMON_UNREACHABLE ### Response: (Severity: 2), (Category: INFRA), (Description: The IOS-XR appmgr has failed to connect to the docker daemon. Docker related functionality will be unavailable. It may be possible to recover by taking the following steps: - Restart the docker daemon, and then restart the process appmgr on the impacted node. - Reload the impacted node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO-3-ERR_QAD_NOTIF ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to get the qad notification of queue depth above or below watermark. This normally indicates there is some issues with the qad queue %p - QAD queue id), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCTRL-6-SETTING_PXE_BOOT_MODE_FAIL ### Response: (Severity: 6), (Category: LIB), (Description: 'At reload, setting boot mode to PXE failed'), (Recommended Action: 'Try another reload of the card') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_FPOE_DB_CORR_ECC_ERROR_LNK0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast FPOE correctable ECC error on link 0), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_LASER_CASE_TEMP ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-PLL_T0_STATE_HOLDOVER ### Response: (Severity: 3), (Category: PLATFORM), (Description: No external reference frequency is available for synchronization, so the T0 PLL output is in holdover, maintaining the most-recent frequency to which it was locked.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-5-IFH_MISMATCHED ### Response: (Severity: 5), (Category: IP), (Description: A mismatch in interface handles has been been detected. This is an indication that IM is potentially out-of-synched with MA. This problem occurs when interfaces are deleted while Interface Manager (IM) is not available.), (Recommended Action: The problem is normally recovered by the IPV4-MA component. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-4-SATELLITE_UPGRADE_ON_CONNECT_SET ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The user has configured the satellite to auto-upgrade on connection if the satellite is not at a current version, and the specified satellite is currently not at a current version. Therefore, if the connection to the satellite is dropped and re-established, then the satellite will start to perform an auto-upgrade which may temporarily take it out of service.), (Recommended Action: It is recommended to either: - remove the upgrade on connect configuration, until the user has manually upgraded the satellite to the current version. - trigger an upgrade to the current version (or reset the connection) as soon as possible to ensure that the auto-upgrade occurs at a known time) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-SYSDB_DELETE ### Response: (Severity: 7), (Category: INSTALL), (Description: This may not affect the current request or operation, but subsequent operations may be affected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_FWD-3-SYSDB_BIND_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Some error occured in sysdb bind operation bind. The text of the message displays the failed operation for the bindpoint with error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-2-DEVICE_ISSU_NOTIFICATION ### Response: (Severity: 2), (Category: PLATFORM), (Description: This notification indicates when npu driver has encountered a specific notification.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-3-SPAN_INIT_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An error was encountered while the SPAN module was initializing. The error message contains details about the source of the error.), (Recommended Action: This problem may indicate there was an issue during SPAN init. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How are DRs and BDRs elected in OSPF? ### Response: DR/BDR election is done on broadcast and NBMA networks. Routers send hellos containing their router priority. The highest priority becomes the DR and the second highest the BDR. If priority is equal, highest router ID wins. Priority of 0 makes a router ineligible to become DR/BDR. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-6-ENCAP_REMOVED_PW_CLEAR ### Response: (Severity: 6), (Category: L2), (Description: Encapsulation in the pw-class is set, all pseudowires attached to this pw-class should be out of the unresolved state.), (Recommended Action: No particular action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-INSUFFICIENT_BUFFER_SIZE ### Response: (Severity: 3), (Category: SECURITY), (Description: A buffer is required in order to fill a certain data but the buffer size was too small.), (Recommended Action: Collect the output of show logging and inform Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-2-HBLOSS_COLLECT_LOGS ### Response: (Severity: 2), (Category: PLATFORM), (Description: The indicated process detected partial heartbeat loss for active RP/SC node's sc_reddrv. Debug logs are collected on the bootflash locally to help identify the the root cause of the heartbeat loss.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-INIT_EVENT_MGR_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failed to initialize event manager. This would prevent process from receiving events.), (Recommended Action: A process will be initiated by the software. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If restart din't fix the problem) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-GET_TRAFFIC ### Response: (Severity: 3), (Category: ROUTING), (Description: CLNS show command failed to get the required information.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-NODE_LOOKUP_FAILURE ### Response: (Severity: 7), (Category: OS), (Description: An attempt to use a QSM link was made -- but the remote node that exported the link to the local node was not in the local nodes database. This could be a harmless timing condition.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_ERRORS-7-ERR_SYSDB_BAG_ENCODE ### Response: (Severity: 7), (Category: L2), (Description: ASIC error library encountered a SYSDB encode error while performing the indicated operation.), (Recommended Action: An error would be reported to the client application which should handle this condition appropriately. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_1_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_TOPAZ-7-ERR_HEARTBEAT_FAILURE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server heartbeat monitoring mechanism detected interruption in the periodic 'Hello' messages.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-5-STALE_DEVICE_ENTRY_DISCARDED ### Response: (Severity: 5), (Category: PLATFORM), (Description: platform umass device number is called by PI code to return a unique device number for the device just discovered. This device number is used to construct the raw device name which in turn is also passed to mediasvr by PI. The mediasvr will use the raw name to look up partition and filesystem information in the node's platform_fsdata file so it can correctly mount the partitions and reformat them as needed. This message gets printed when the PI caller of get device number has allocated a fresh cdevice entry and removed any stale entry.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-DUPLICATE_TICKET_NOTIF ### Response: (Severity: 7), (Category: OS), (Description: When the single writer mode is set, RDS library allowes to create a ticket. Got a ticket notification, for an already active ticket.), (Recommended Action: This is a Debug message.No action required. If the problem persists,Contact Support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_TOPAZ-3-ERR_QAD_GET_DEPTH ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to get the qad queue depth(number of packets in queue). This should be because of some issues with the indicated qad queue %p - QAD queue id), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_8_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WD_DISKMON_SYSADMIN-1-DISK_ALERT ### Response: (Severity: 1), (Category: INFRA), (Description: When some monitored disk's usage is above CRITICAL Threshold Percentage), (Recommended Action: The indicated disk device may be running out of space. Determine if there are unneeded files on the disk.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4MC_STATIC-7-ERR_ROUTE ### Response: (Severity: 7), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-6-PRE_PROVISIONING_ACTIONS_INITIATED ### Response: (Severity: 6), (Category: INFRA), (Description: ZTP will trigger the pre-provision actions detected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR ensure software package integrity during installation? ### Response: Cisco IOS XR ensures software package integrity during installation through the use of digital signatures and checksum verification, preventing the installation of tampered or corrupted packages. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2TP-3-L2TP_CC_ACCT_NO_ACK ### Response: (Severity: 3), (Category: L2), (Description: L2TP has not received acknowledgements, either positive or negative, for tunnel accounting records it sends to Radius in an extended period of time.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-ERR_EVM_CRE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The process failed to create an Event Manager to receive events in the specified thread. This is most likely to be caused by a resource starvation problem, but may also be due to an internal programming error.), (Recommended Action: Restart of EIGRP might solve the problem. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SYSDB_ITEM_BAD ### Response: (Severity: 7), (Category: OS), (Description: Dumper keeps various config related data in sysdb. Unexpected or bad item under config for dumper. This might impact the funcitoning of the dumper.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. follow process 6. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-2-MOBILE_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The Sync-E is configured without the necessary mobile license.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-CFG_CHG_RESET ### Response: (Severity: 5), (Category: ROUTING), (Description: Automatic soft reset on policy change is not possible as the neighbor does not support ROUTE_REFRESH and 'soft-reconfiguration inbound' is not configured.), (Recommended Action: Manually clear affected peer at earliest convenience, in order for configuration change to take effect.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-5-SC_BIND ### Response: (Severity: 5), (Category: SYSDB), (Description: Sysdbcon was unable to bind to the root of SysDB. It is possible that there is a problem with SysDB.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the fast-flood command in IS-IS? ### Response: The fast-flood command is used to enable IS-IS fast flooding. When fast flooding is enabled, IS-IS floods new LSPs before the SPF calculation is complete. This can improve convergence time in some scenarios, particularly in large networks. However, it can also lead to temporary routing inconsistencies and should be used with caution. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-6-TIMER_EXPIRED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that a timer shelfmgr was using to monitor a nodes boot progress has expired.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you discard unsaved configuration changes in IOS XR? ### Response: To discard unsaved configuration changes in IOS XR, you can use one of the following methods: (1) exit configuration mode using 'end' or 'exit' commands, (2) use the 'abort' command to discard changes and release the configuration lock, or (3) use the 'clear' command to reset the configuration session. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the Cisco IOS XR System Manager (sysmgr)? ### Response: The System Manager (sysmgr) is responsible for overall system initialization, monitoring, and restart functions. It is the first process started on each node. It spawns, monitors, and can restart other processes based on their criticality and restart policies. It also coordinates role transitions between active and standby RPs. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-MASTERSHIP_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Chassis Control driver process exited as it was not able to grab mastership or unable to release it.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-4-CHKPT_REGISTER_FAILURE ### Response: (Severity: 4), (Category: SECURITY), (Description: Encountered a checkpoint register failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BLWM-4-SHMEM_FAILURE ### Response: (Severity: 4), (Category: OS), (Description: A failure occurred while initializing or accessing the shared memory buffer used to assemble the responses. This is most likely an internal error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-OS_BOOT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: OS running on the indicated card is reporting an error condition during bootup.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-6-SESSION_BUNDLE_ALL_MEMBER_ON ### Response: (Severity: 6), (Category: L2), (Description: The specified BFD session is now running in all member mode.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of using the 'install add' command in Cisco IOS XR? ### Response: The 'install add' command in Cisco IOS XR is used to add new software packages to the router without disrupting the current operation, allowing for seamless updates and upgrades. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_HFR-3-CFG_NOTIF_SETUP ### Response: (Severity: 3), (Category: ROUTING), (Description: MFWD-HFR library encountered error during config notification registration.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_IN_MEM_UCORR_ECC_ERROR_LNK3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast input memory uncorrectable ECC error on link 3), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PM-5-DUMP_FAIL ### Response: (Severity: 5), (Category: MGBL), (Description: An error has occurred while dumping of the collected data from the pm collector process. This error could error due to various reasons below : a) Local disk is full or something wrong. b) TFTP server is not reachable. c) TFTP directory configured does not have write permissions.), (Recommended Action: Try eliminating the reasons mentioned in explanation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ORA-3-THREADING_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The presented threading operation failed. It is likely that policy multi-version calls will stop working and thus policy may not be operational.), (Recommended Action: Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-DDR_LOSS_OF_SYNC_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Loss of sync on DDR interface on bridge instance-1.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON-3-FAM_CONNECT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Connection to FAM process failed during AFMon EA process init. This would lead to an inablility of AFMon EA to receive flow updates from the hardware), (Recommended Action: No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE* Else try restarting manually. Get the job id 'show processes afmon_ea location <>' 'process restart location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-5-SOME_SATELLITES_NOT_RESYNCED ### Response: (Severity: 5), (Category: L2), (Description: CFM was unable to ascertain the status of one or more Satellites within 5 seconds of starting up. This means some CFM functionality will not be available on these Satellites, even though they may be up.), (Recommended Action: The problem may resolve itself given sufficient time, otherwise reduce other system activity to ease memory and CPU demands. Check that the EtherSla channel shows as 'open' in the output of 'show nv satellite protocol control'. If CFM still doesn't come up on configured Satellite links to these Satellites, collect the required information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WAN_INARP-3-UNKNOWN_IDB ### Response: (Severity: 3), (Category: L2), (Description: A set of IDBs are kept with information on each interface. Somehow this information has become inconsistent with the system.), (Recommended Action: Restart the main process (containing the InARP DLL) If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_BRIDGING-7-ENQUEUE_MAC_COUNT_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: While enqueueing MAC record in MAC list, index is out of bound in the array.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TIMER-3-TW_CREATE_TIMESLICE_TOO_SMALL ### Response: (Severity: 3), (Category: OS), (Description: The kernel will override a request to create a repetitive timer of less than 100ms on a priority 10 thread and internally use 100ms. This could cause software using this timer wheel to behave extremely badly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is just an info message in DPA), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef trace location <> show cef platform trace common all location <> show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TAMSVCS-3-TAM_SYNC ### Response: (Severity: 3), (Category: SECURITY), (Description: tam_sync process has encountered an internal error.), (Recommended Action: Please restart tam_sync process on affected node, for an attempt to recover from error. Note that not all error conditions can be recoveded by process restart.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-CRITICAL_ALARM_RESET ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node will be brought down because a critical environmental alarm occured.), (Recommended Action: Check air-flow, fan trays, and make sure that chassis is well-cooled. Manually boot up the node once the chassis has been checked.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-3-RULES_PARSE_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The rules file cold not be parsed. Please check the rules file.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_DYNREG-3-AP_DELETE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered as attach point data was being deleted. This could cause problems with future configuration attempts, and it does indicate an internal inconsistency so it might be best to restart the policy_repository to try to clear this inconsistency.), (Recommended Action: Restart the policy_repository process and check for re-occurence of issue If problem persists, the please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-4-EA_INIT ### Response: (Severity: 4), (Category: FORWARDING), (Description: The Tunnel-IP EA process failed to initialize a critical component. The process cannot proceed and will restart to recover.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FM-3-ALARM_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Autogenerated alarm), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-TIMESTAMP ### Response: (Severity: 3), (Category: ROUTING), (Description: A software operation failed during timestamp processing.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR-3-EA_DROP ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates that PBR failed to process an invalid packet. The expected forwarding action will not be taken.), (Recommended Action: An error may have occurred in the hardware or lower layer processes. Invalid packets are delivered to pbr_ea. Please collect the information specified in required_info section and contact Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEPKI-3-MIB_LWM_CONN_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: 'Could not connect to pki mib channel. Snmp traps will not be sent'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_8_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-IFMGR_IF ### Response: (Severity: 3), (Category: ROUTING), (Description: The specified interface manager request failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-BAG_REG_ERR ### Response: (Severity: 3), (Category: L2), (Description: Some error occured while trying to register edm bags. The text of the message displays the failed operation with error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INVMGR-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that process invmgr failed to initialize and exited. Inventory information would not be available. This would affect CLI 'show inventory', inventory schema, and the entity related MIBs. Some reasons are: 1) System manager process ready notification failed 2) Error waiting for secondary RP to go active 3) Internal API error %s - indicates the internal message. %s - indicates the internal error reason.), (Recommended Action: System manager will automatically respawn this process, up to a fixed number of times, when this error is encountered to recover. Execute 'show process invmgr location 0/x/cpu0' to verify that the process is up and running. If it is non-operational, do 'process restart invmgr location 0/x/cpu0' to manually restart it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ET1_INTR_MISSING_EOP_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ET1_INTR_MISSING_EOP interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_MQ_SEQ_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue sequence error on XAUI 0 MQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-4-RED_STATE_UNK ### Response: (Severity: 4), (Category: SERVICES), (Description: A notification has been received from Sysmgr indicating that the redundancy state (e.g. active, standby, etc) of the card has changed to a state unknown to RSPP MA. RSPP MA will continue to use the old state.), (Recommended Action: A restart of RSPP MA may solve the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_IR1_INTR_DC3_MIN_DROP_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_IR1_INTR_DC3_MIN_DROP_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ERRDIS-4-CHECKPOINT_FAILED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: When an interface is error-disabled, the state is checkpointed. An error occurred during this process, which means the error-disable state for this interface will not be preserved during an ISSU operation.), (Recommended Action: Do not perform an ISSU if it is essential that the interface is error-disabled after the ISSU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-3-SEND_ERR ### Response: (Severity: 3), (Category: IP), (Description: An attempt to transmit a valid packet to the identified adjacency failed due to an internal software error.), (Recommended Action: Check to see if the tcp process had restarted. If it has, no further action is needed. The remote ANCP clients should restart the connection. The rates for any configured ports previously in UP state will go to DOWN state but their published rates will remain the same. If the tcp process hadn't restarted, then from the CLI, try to clear the ancp neighbor. The adjacency would be re-established and packet send should be successful henceforth. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_2_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Rx power greater than or equal to the high Rx power alarm threshold. The QSFP+ is the pluggable optics on the line cards. The Rx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-CORE_INFO ### Response: (Severity: 4), (Category: OS), (Description: Debug core info), (Recommended Action: Information of the crashed process. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'next-hop-self' command in IOS XR BGP configuration? ### Response: The 'next-hop-self' command causes the BGP speaker to set itself as the next hop for routes advertised to a neighbor. This is commonly used when the BGP speaker is aggregating routes from multiple neighbors and advertising them to another neighbor. Setting next-hop-self ensures that the receiving neighbor has a route to reach the advertised prefixes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_MCAST-3-ERR_STR_RT ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM MCAST, error information), (Recommended Action: Please collect the console log, multicast traces (show mfib trace loc <>, show mfib hardware ltrace location <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-ID_CERT_RENEW_NOT_STARTED ### Response: (Severity: 3), (Category: LICENSE), (Description: The device registration failed. The ID-Cert start date is later than the device current time.), (Recommended Action: Please adjust your device clock to be up-to-date, and retry the registration again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RLOGIND-3-ERR_FATAL ### Response: (Severity: 3), (Category: IP), (Description: Fatal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HPISSE-7-DEBUG_INFO ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-7-NOT_IMPLEMENTED ### Response: (Severity: 7), (Category: HA), (Description: Unimplemented functionality.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the mesh-group command in IS-IS? ### Response: The mesh-group command is used to optimize IS-IS flooding on highly meshed point-to-point networks. Routers in the same mesh group do not flood LSPs received from one member to other members of the same mesh group. This reduces unnecessary flooding and saves link bandwidth. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_0_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install prepare command in IOS XR? ### Response: The 'install prepare' command is used to prepare the system for an installation operation. It checks for available disk space, performs configuration checks, and determines which processes will be affected by the installation. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_AHS_LOS_LANE1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LICENSE-2-ENFORCE_OOC ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature is enabled without appropriate licenses.), (Recommended Action: The customer should either purchase more licenses or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-RCC_HW_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver cannot initialize with the RCC HW init library. Possible fabric multicast feature may not function correctly.), (Recommended Action: Collect all the event and console logs. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-4-NEXTHOP_RESOLUTION_DEPTH ### Response: (Severity: 4), (Category: ROUTING), (Description: Recursive route lookup for resolving the prefix has exceeded the maximum recursion depth allowed(possibly because of a routing loop).), (Recommended Action: The current state of nexthop resolution can be seen by using the command 'show rib firsthop'. To further troubleshoot this state use commands like 'show route', 'show route backup', and 'show route resolving-next-hop' recursively to resolve the prefix manually. The output of these CLI commands will help to identify the reason for hitting recursion depth limit. 'show rib recursion-depth-max' can be used to check the value of maximum recursion depth allowed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-4-SECURE_BOOT_NOT_ENABLED ### Response: (Severity: 4), (Category: DRIVER), (Description: The Secure Boot feature for IOFPGA bootflash images are not present in the card. This message is a reminder to the user that a FPD upgrade operation is required to enable this feature.), (Recommended Action: Use 'hw-module location all fpd all' command to initiate upgrade of IOFPGA bootflash with Secure Boot enabled images.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-ERR_SHM_OPEN_FAILED_DEVICE_TEMP ### Response: (Severity: 3), (Category: FABRIC), (Description: 'Might be memory problem, setting size limits could be issue or memory mapping could have failed. Or initializing or setting shared attributes for the lock could have failed.'), (Recommended Action: Reboot the card) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-2-LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected an SFP Rx power less than or equal to the low Rx power alarm threshold. The SFP is the pluggable optics on the line cards. The Rx power threshold values are read from the SFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SYNC-7-FILE_BAD_MAGIC ### Response: (Severity: 7), (Category: OS), (Description: The file has wrong magic number.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-ERR_SYSDBBIND ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_6_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_6 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-ERR_CREATE_SERVER_ENTRY ### Response: (Severity: 3), (Category: SECURITY), (Description: Error occured while creating TACACS+ server entry.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_VLAN_EA-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: DNX VLAN-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-SLICE_MOD_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. 'process restart i2c_server location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-4-DEVICE_CREATED_AND_DISABLED ### Response: (Severity: 4), (Category: OS), (Description: A device is disabled for logging onboard by user configuration.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POS-2-NOMEM ### Response: (Severity: 2), (Category: L2), (Description: The requested operation couldn't be completed due to a low memory condition.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - If this message is persistent, check memory usage - Try to have sufficent memory conditions) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV6-3-GEN_ERR ### Response: (Severity: 3), (Category: L2), (Description: An IPV6-specific software error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SEG_HDR_FIFO_OFLOW_0_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress seg hdr fifo overflow on xaui-0 bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HBAGENT-4-SET_THREAD_PRIORITY ### Response: (Severity: 4), (Category: PLATFORM), (Description: Unable to set the heartbeat pulse of this node to high priority. Proceeding with default priority, however in a high CPU consumption, this node's heartbeat pulse may get lost, causing this node to get reloaded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGEDM-3-FAILEDGET ### Response: (Severity: 3), (Category: MGBL), (Description: 'Config library failed to get item with the reason mentioned in the message. This may lead to wrong 'show commit changes diff'.'), (Recommended Action: Please collect the logs mentioned in required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-NULL_ARG ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to inavlid_arguments. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIAAPI-4-INVALID_PARM_REPORT_ERROR ### Response: (Severity: 4), (Category: MEDIA), (Description: Application reported storage device problem but with invalid parameter shown), (Recommended Action: Capture console log, 'show media' and 'show media trace' output. Report this message to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option dynamic attributes feature? ### Response: The MPLS TE path-option dynamic attributes feature allows certain LSP attributes to be specified for a path-option without configuring an explicit path. LSP attributes that can be specified include bandwidth, priority, affinity, and setup and hold priorities. This provides a way to influence the dynamic path calculation with additional <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKS_SRVR_ENGINE-3-ERR_3_PARAM ### Response: (Severity: 3), (Category: SECURITY), (Description: SKS server exp error message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-2-ERR_MEM_ALLOC ### Response: (Severity: 2), (Category: ROUTING), (Description: There is not enough memory available to RIP process.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR-3-CERR_REG_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cerrno Registration failed. This may be a program level error. The failure will cause the Procmgr process to restart.), (Recommended Action: The Procmgr process will automatically respawn up to a fixed number of times. Verify the process is running: 'show process procmgr location <>' If it is still not spawned contact support with the required info. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IPV6_EA-3-ERR_INFO_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Typically, this is an error where the software fails due to failure during forwarding feature programming. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show cef ipv6 location <> show cef ipv6 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-VALIDATE_FILE_FAIL_LOW_MEM ### Response: (Severity: 3), (Category: MEDIA), (Description: Could not get enough memory while trying to sanitize nvram.), (Recommended Action: 'Router running low in memory. Reboot if possible.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-GEN_ERR_3 ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA driver encountered an Error in operation. The error string updates the reason for this error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_MRT-7-DEBUG_CLEANUP ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when cleaning up debug.), (Recommended Action: Restarting the process may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-CHKPT_NOT_INITIALIZED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Sync-controller is the software component which controls the synchronization devices in the system. Checkpointing is a mechanism to update the redundant RSP with the current configuration and status of the system to help takeover in case of a failover. The checkpoint mechanism needs to be initialized for Sync-controller to update the standby RSP with current frequency syncronization status. This failure could be because of memory allocation failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDLD-4-INTF_RETRY ### Response: (Severity: 4), (Category: L2), (Description: The UDLD protocol encountered an error while syncing interface configuration, and has scheduled a retry of the failed interfaces. This message is seen on the first retry, and every 5 retries.), (Recommended Action: If this is the first time the message is seen, it is likely that the retry will succeed, and no action is needed. If the retry count is greater than one, this indicates an ongoing problem, and the failure should be investigated.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_2_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-CPT4_DEV_VERSION_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: PHY controller driver version is not compatible with PHY controller hardware version.), (Recommended Action: Upgrade the PHY controller CPLD image using the FPD procedure, followed by reloading the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-6-UNSUPPORTED_VENDOR ### Response: (Severity: 6), (Category: SECURITY), (Description: An internal software error has occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-INTERNAL ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process has either failed a function that expected to succeed, or has got into an inconsistent state.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-LS_LFI_CRC_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected a lfi crc error), (Recommended Action: Please try to correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ILITE-3-UNKNOWN_VENDOR_TYPE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Unable to get vendor type, this may be a program level error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: libpcmcia_linux-7-MALLOC_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Low in memory), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_ASIC_HARD_RESET ### Response: (Severity: 3), (Category: FABRIC), (Description: Identified Fabric ASIC experienced a severe error and is halted. Hard reset & re-initialize the ASIC to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_V6FIB_RP-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform IPv6 FIB, Error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-TTY_MGMT_REG_SUBSET ### Response: (Severity: 3), (Category: MGBL), (Description: The call to tty_mgmt_register_tty_subset() failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_PRE_FEC_BER_HIGH ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-LWM_API_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: Failure in LWM client API.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_MA-6-STATS_COUNTER_INCONSISTENCY ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-ENS_PUBLISH ### Response: (Severity: 7), (Category: OS), (Description: RDS library uses ENS/GSP services to read/write data. While using ens API , it returned failure. ens_publish failed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFEA_IPV6_EA-3-ERROR3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: AFEA IP-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP_POLICY-3-ORA_INSTBUILD ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error in the routing policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDEVINFO-3-MAIN_INIT_ERROR ### Response: (Severity: 3), (Category: MEDIA), (Description: One of the functions called during initialization of the process failed.), (Recommended Action: restart process 'fs_dev_info' from exec prompt - from exec prompt 'restart process fs_dev_info' if issue persists contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_SYSDB_REG_NOTIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE tunnel load-share feature? ### Response: The MPLS TE tunnel load-share feature allows the control of how traffic is load-balanced between two or more parallel TE tunnels to the same destination. By default, load-balancing is based on a hash of the packet header fields. Optionally, the load-share value can be specified manually to control the proportion of traffic to each tunnel. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPG-6-INCOMPLETE_DATA_RETRIEVED ### Response: (Severity: 6), (Category: MGBL), (Description: An error occurred on a specific area of the namespace while requesting information for a higher level path. The specific area of the namespace with the error has been returned with empty data. Data in the rest of the namespace is returned as normal.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Pass the syslog and configuration information to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-PARTNER_NODE ### Response: (Severity: 3), (Category: OS), (Description: Unable to query partner node from platform.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_SPECIAL_HANDLE_THRESH ### Response: (Severity: 1), (Category: PLATFORM), (Description: ASIC errors have occured and been handled. Such error have crossed threshold.), (Recommended Action: ASIC errors that need special handling have occured and exceed the threshold. The error condition has been handled.Collect required information and contact TAC *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: 12IN1-4-UPDOWN ### Response: (Severity: 4), (Category: L2), (Description: The specified Serial 12in1 interface is operationally down due to an alarm. Check alarm status using show controller 12in1-T command on the cli.), (Recommended Action: Recommended action is to repair the source of the alarm.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-0-CARD_RESET_ABORTED ### Response: (Severity: 0), (Category: PLATFORM), (Description: The card reset was aborted because the user has disabled card reset to allow troubleshooting to be performed.), (Recommended Action: Manually reset the card to bring the card back to a known steady state.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-CONNECT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The error indicates failure in connecting the channel.), (Recommended Action: Please collect the console log and the CLI output. Copy the error message exactly as it appears on the console or in the system log. Issue the cmd command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the cmd output, call your Cisco technical support representative and provide the representative with the gathered information. show cef show cef location <> show cef trace location <> show cef platform trace common all location <> show cef platform services resource oor common loc show cef platform services resource shm-objects common loc show cef platform services trace common all reverse loc show cef platform services trace common errors reverse show cef platform services trace common all reverse loc Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information. show cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-UNRESOLVED_LINKPOINT ### Response: (Severity: 3), (Category: MGBL), (Description: 'Unresolved linkpoint'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_AIS_DEME ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-EVENT_CREATE ### Response: (Severity: 3), (Category: OS), (Description: PlaceD daemaon was unable to create an event manager for receiving messages, and therefore failed to initialize. Recovery occurs with automatic process restart.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-TARGET_CFG_DESTROY ### Response: (Severity: 3), (Category: MGBL), (Description: Nvgen client failed to destroy target config buffer.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-LBUS_WRITE_TIMEOUT ### Response: (Severity: 1), (Category: PLATFORM), (Description: Local Bus write operation timeout error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS LDP graceful restart feature? ### Response: The MPLS LDP graceful restart feature helps to minimize the impact of LDP session resets, allowing MPLS forwarding to continue uninterrupted while the control plane restarts. It preserves the MPLS forwarding state across the restart. It is enabled with the mpls ldp graceful-restart command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-FAILED_FILESYSTEM_ACCESS ### Response: (Severity: 4), (Category: MEDIASVR), (Description: When periodic check on the filesystems detects that a file-system is inaccessible, this error message is logged. *SUPPORT*), (Recommended Action: Contact TAC for further support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_DRIVER-3-SW_ERR ### Response: (Severity: 3), (Category: L2), (Description: Driver software error), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBCSVI_NETIO-3-INIT_TRACE ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of tracing for the NetIO caps. This will cause the capsulation to be unloaded, and an error returned to the user.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ST16550-3-SEM_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The ST16550 UART driver was unable to perform semaphore operation for interrupt handler.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCMD_LIB_XFORM-3-VERSION_MISMATCH ### Response: (Severity: 3), (Category: ROUTING), (Description: A version mismatch detected by RCMD, the message was discarded.), (Recommended Action: Report to Technical Support. Can happen during ISSU/upgrade operation but is not service affecting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLX8749_CDMA-6-NOT_SUPPORTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message indicating that pak type is not supported), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-BF_OVR_ERR_FIA10 ### Response: (Severity: 3), (Category: PLATFORM), (Description: FIA10 burst FIFO overflow error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB_LIB-3-BATCH_BUFFER_SEND_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Error in batch buffer sent for redist register.), (Recommended Action: Restarting the client process from which the errow was emitted may fix the problem. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_DRV-3-ERR__SHMEM_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in platform component,during shared memory creation), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-PWR_BUDGET_ENFORCEMENT_DISABLED ### Response: (Severity: 4), (Category: PLATFORM), (Description: The power budgent will not be enforced by the software. All modules will be allowed to boot up. This may cause chassis reload or hardware damage if the system is overloaded with modules that take up higher power than what is available.), (Recommended Action: Ensure that the system has enough power. Use the Copy the error message exactly as it appears on the console or in the system log. Issue the (admin)# show environment power-supply command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin)# show environment power-supply output, call your Cisco technical support representative and provide the representative with the gathered information. command to do the same. Remove *power budget enforcement disable* from the admin config unless otherwise needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_CONFIG-7-ERR_EVENT_CREATE ### Response: (Severity: 7), (Category: OS), (Description: Event conn create failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-2-ETHER_XCVR_CODE ### Response: (Severity: 2), (Category: L2), (Description: The xcvr code is displayed for both supported and unsupported sfp/xfp types for the following actions - OIR of SFP/XFP - Soft and Hard OIR of SPA/LC - unshut of SPA - Enabling power for LC), (Recommended Action: No actions are required as this is just an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_CLEAR_UNKNOWN_TABLE ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process received a clear event from RIB for a table which it was not tracking.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-2-RESET_RECOVERY_FAILED ### Response: (Severity: 2), (Category: INFRA), (Description: When the Ethernet Switch Driver (ESD) process encounters certain switch errors, it initiates a switch reset recovery operation. This involves resetting the switch and then exiting the ESD process so that it is restarted by the process manager. If this reset recovery operation fails, ESD will escalate a fault to the shelf manager in order to reload the card to recover from the originally reported switch error.), (Recommended Action: To determine why the switch reset recovery operation failed, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet' and 'show tech-support ctrace' commands. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. In addition, the recommended action for the originally reported switch error should be followed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_EVENT ### Response: (Severity: 3), (Category: OS), (Description: A call to a event manager interface failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSM-3-ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failure in Multishelf Manager.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SECY_DRIVER-0-KAT_FAIL_DETECTED ### Response: (Severity: 0), (Category: L2), (Description: Secy Driver has detected POST(Power On Self Test) KAT(Known Answer Test) failure, for the specified Port No. The Encryption and Decryption capabilities of MACSEC capable PIDs are tested against Known CT/PT values. If any port fails KAT test then all the ports on the card are brought down and put in error state. No traffic shall pass through on the MACSEC capable PID which failed KAT.), (Recommended Action: Collect showtech support optics and showtech support ofa. Deactivate the faulty card and contact TAC to examine this card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-7-LICENSE_RECLAIMED ### Response: (Severity: 7), (Category: LICENSE), (Description: Due to a loss of inter-process communications the license manager had to reclaim a license that was not properly released.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-CHASSIS_OVERTEMP_CLEAR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Chassis ambient temperature has returned to operating range. Ambient temperature is the average of the temperature inlet sensor for all RSP plugged in the chassis.), (Recommended Action: None required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_OPTICS_TEMP_OUT_OF_RANGE ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_EVM_EVENT_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-3-EVM_FAIL ### Response: (Severity: 3), (Category: MGBL), (Description: An internal error was encountered while initializing event manager for default configuration verification thread. This condition might have been caused by the failure of the event_block() API.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please collect 'show tech-support cfgmgr', 'show tech-support sysdb', 'show tech-support rdsfs' and 'show process blocked'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-TM_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: The asic traffic manager initialization failed due to the above mentioned error.), (Recommended Action: Collect all the event logs and the output of the following commands executed from the CLI of the active RP: 1. 'show process fia_drvr location ' 2. Collect the Broadcom ltraces: pkg/bin/fia_show_ltrace -S If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_STORM-3-SC_MODIFY_ERR_INTF_NAME ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to program storm control as it is conflicting with an existing AC), (Recommended Action: Remove storm control config on this sub-interface) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA-3-RADIX_FAIL ### Response: (Severity: 3), (Category: IP), (Description: An internal error occured while updating an internal node database.), (Recommended Action: Do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-3-DB_INT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform Fault Manager NFM encountered an error due to internal software issue and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-INVALID_PATH ### Response: (Severity: 7), (Category: OS), (Description: Most probably tried to configure an unsupported path e.g. rcp. Configure a valid path.), (Recommended Action: 'Configure a valid path') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_LSD-7-ERR_INIT ### Response: (Severity: 7), (Category: ROUTING), (Description: MPLS LSD failed to initialize for the reason displayed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-4-AVL_TREE_INIT ### Response: (Severity: 4), (Category: ROUTING), (Description: The MRIB encountered error while initializing AVL Tree structure for FGID), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-4-MPLS_STATS_HW_PROFILE_MISMATCH ### Response: (Severity: 4), (Category: FABRIC), (Description: 1. Mismatch found between the current stats profile and the newly configured stats profile. Needs attention with LC reload.), (Recommended Action: System LC is inconsistent. Need to reload the LC in order to activate the new stats profile. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-4-WARNING2 ### Response: (Severity: 4), (Category: SECURITY), (Description: Internal Warning.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRLLIB-3-UNRECOVERED_PIO_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A PIO error was detected and the responsible client was notified but did not mark the error as recovered. Restarting the client.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_MPLS_EA-3-ERR_INIT_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in MPLS EA. Typically, this is an error where the software fails to initialize or programming of forwarding feature fails. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef mpls trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-MISSING_SUBGRP ### Response: (Severity: 4), (Category: ROUTING), (Description: BGP detected that a Neighbor AF did not correctly belong to an update sub-group. BGP attempted to correct this error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-3-CFGMGR_ERROR_MSG ### Response: (Severity: 3), (Category: L2), (Description: The pse_pol_cfg was unable to connect or send admin proc ready to cfgmgr.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-ADJ_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred when FIB tried to communicate with AIB. The process will attempt to recovery by restarting. If the restart count is excessive then the node may reload. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_INTERNAL_CHECK ### Response: (Severity: 3), (Category: ROUTING), (Description: An inconsistency in internal state was detected.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-7-ERR_BP_CFG ### Response: (Severity: 7), (Category: FABRIC), (Description: The Fabric driver encountered an error in back pressure configuration. This indicates BP configuration received from the fabric control software is incorrect. If this condition prevails, it could impact data traffic when fabric gets congested.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_HWOFFLOAD-4-NP_SCALE_LIMIT ### Response: (Severity: 4), (Category: PLATFORM), (Description: NP level scale limit has been reached.), (Recommended Action: All new sessions on this NP will be kept in ADMIN-DOWN state.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMP-6-PROC_READY ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WATCHDOG-3-MSG_REPLY_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: This message indicates that a failure has occured in Watchdog), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_LIB-3-SERVER_CONNECT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: A communication problem occurred between the MBI client and server, perhaps because the communications infrastructure is not yet up. The MBI operation in progress will not be carried out. %s - indicates the error message.), (Recommended Action: Unless the connection was retried and eventually successful, further information will need to be collected. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_CLIENT-3-GEN_ERR ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA driver encountered an Error in operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-6-SELFMANAGE_INFO ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Netio is upgrading this dll. This is here only for informational purpose only. No further action is recommended/needed.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GDO-5-L2PORT_FAULT_NOTIFY ### Response: (Severity: 5), (Category: L2), (Description: ATM SPA GDO L-AIS insertion/removal notification messages), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key characteristics of the QNX Neutrino RTOS used in IOS XR? ### Response: QNX Neutrino is the third-party real-time OS used as the foundation for IOS XR. Its key characteristics are\n- Microkernel architecture\n- Preemptive multitasking and multithreading\n- Memory protection and fast context switching\n- Message passing based IPC\n- POSIX compliance\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-CLIENT_ID_OVERWRITE ### Response: (Severity: 4), (Category: ROUTING), (Description: This message indicates that more than one instances of IGP protocols are using the same BGP-LS identifier. This may result in incorrect behavior.), (Recommended Action: Configure the IGP instances so that each has unique BGP-LS identifier.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure BGP session groups in IOS XR? ### Response: BGP session groups in IOS XR are configured to group common session parameters for multiple neighbors, simplifying configuration. router bgp 65000 session-group CORE-SESSIONS remote-as 65002 update-source Loopback0 commit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_8_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SESSION-3-DEBUG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to initialize or shutdown the debug module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LICENSE_UDI-3-RETRIEVE_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Can not retrieve licensing UDI data from backplane or the UDI string retrieved is invalid or mismatch.), (Recommended Action: Ensure backplane chassis serial number is correctly programmed. Issue 'show inventory chassis' in admin mode to verify backplane serial numbers, the valid Cisco serial numbers are made up of decimal digits and upper case letters following Base 36 numeral system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: A function has failed in Shelf Manager. The details are supplied in the msg.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_NB_SERDES_2_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data north bound serdes link 2 failure on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are user-defined EEM policies in Cisco IOS XR? ### Response: User-defined EEM policies in Cisco IOS XR allow network administrators to create custom policies using the Cisco IOS XR command-line interface (CLI) or a script. These policies can be tailored to specific requirements and can perform various actions based on triggered events. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-MISSNUMBER ### Response: (Severity: 4), (Category: MGBL), (Description: The command entered requires a number and one was not supplied.), (Recommended Action: Use the help command to determine the correct usage for this command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-5-RECV_LACP_MCAST_MAC ### Response: (Severity: 5), (Category: L2), (Description: EVPN receives the CE's System ID from LACP for use in EVPN as the PBB-BSA. It cannot be used if the Multicast bit is set.), (Recommended Action: Reconfigure the CE's System ID within LACP without the Multicast Bit set.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install commit command in IOS XR? ### Response: The 'install commit' command makes the current active software packages persistent across reloads. Without this command, the router would revert to the previously committed software set after a reload. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-6-MBR_BFD_SESSION_UP ### Response: (Severity: 6), (Category: L2), (Description: The BFD session on the link has indicated that it is UP state. The link has fast-protect BFD protection on it until further notice.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TOPMGR-2-INIT_FAILURE ### Response: (Severity: 2), (Category: PLATFORM), (Description: This syslog is printed when Topology Manager or its clients fail to initialize necessary data structures and memories. If the error originates from the system call the error message is also printed.), (Recommended Action: Based on the system error message the user can tell what went wrong. More likely than not, the user has to restart the system. If the problem persists he or she has to contact Cisco customer support team.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-LIST_UNDEFINED ### Response: (Severity: 3), (Category: SECURITY), (Description: Trying to configure a method list in the line configuration that is not defined in AAA), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-4-INVALID_PLATFORM_EVENT_TYPE ### Response: (Severity: 4), (Category: L2), (Description: The platform has triggered an event that is not recognized. This is most likely due to a bug in the platform layers.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_DAPS_IF ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the DAPS address pool service. The error message describes what operation has failed and why it failed. The most likely reason for this is a connection problem with the DAPS service, but the error could also be caused by low memory resources or programming error.), (Recommended Action: Consider restarting the PPP MA process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-3-INVALID_BPDU ### Response: (Severity: 3), (Category: L2), (Description: STP received a BPDU which would not be decoded in accordance with section 14.4 of the IEEE 802.1Q specfication.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-6-IQ_CFG ### Response: (Severity: 6), (Category: IP), (Description: There are restrictions to use default or 16 tcp internal queues. The text of the message displays more information.), (Recommended Action: For configure to take effect, please restart tcp on each nodes. Else it will taking effect post Router reload. On Router reload, TCP is silently restarted if tcp num-thread configuration is present.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO-3-ERR_IMDR_V1_PREP_CALL_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error was encountered while calling the CCI cleanup function prior to restarting the process as part of an IMDR operation. The parenthesis contain the error code and the corresponding string description for it.), (Recommended Action: Linecard reload. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-5-ERR_RES_PROG ### Response: (Severity: 5), (Category: FABRIC), (Description: An error occured while the Fabricq driver was trying to create queues for an interface. This may leave one or more interfaces out of operation.), (Recommended Action: If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-4-BADFILES ### Response: (Severity: 4), (Category: MEDIA), (Description: Files Overwritten by Another Image, or Router Crashed), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel backup feature? ### Response: The MPLS TE auto-tunnel backup feature enables the automatic creation of backup tunnels to provide fast reroute protection for MPLS TE tunnels and the IGP against link and node failures. Backup tunnels are created to next-hop routers and activated when the protected link or node fails. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-6-SHMWIN_RESET ### Response: (Severity: 6), (Category: INFRA), (Description: SLA Client Library database module shared memory window has been reset. This may have been caused by the process restarting whilst the shared memory window was in an invalid state or a change to the database that is not safe over upgrade.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-6-DEPRECATED_CONFIG ### Response: (Severity: 6), (Category: L2), (Description: The PTP clock-selection and clock-advertisement configuration items are deprecated and will be removed in a future release. These two configuration items have been replaced with a single configuration item to select G.8265.1 (telecom profile) behavior: \'ptp clock profile g.8265.1\'.), (Recommended Action: Use the ptp clock profile configuration item to select G.8265.1 (telecom profile) behavior.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIER-3-PCIE_LINK_DOWN_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Detected PCIE link down on one of the PCIE root/bridge downstream port), (Recommended Action: Current action is to log a PFM message and try to continue as operational so that it wont effect on the ongoing activities. If it is a critical PCIE link down, it will be eventually identified by RSP as heartbeat loss and card will be reloaded by shelfmgr. Post reload, it is expected this fault will recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPIO-3-BUNDLE_OFFLOAD_NOT_SUPPORTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: CFM is configured over bundle interfaces with bundle members configured on trident line cards. Bundle offload is globally configured. Bundle offload is only supported on typhoon line cards.), (Recommended Action: Either disable the bundle offload globally or remove the bundle members from trident line card(s).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-ERR_ECM_OPEN ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA driver failed to open the event connection manager during the driver initialization. The driver will be non-operational due to this error.), (Recommended Action: The driver will escalate the error to the Fault Management (FM) entity for further action. Verify that the driver will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_IPV6_EA-3-ERROR2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: DNX IP-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TSEC-2-DRIVER_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to the reason indicated by the error code. This is critical failure. Driver cannot operate.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRD-4-ERROR_PROCESSING_LRD_EVENT ### Response: (Severity: 4), (Category: SERVICES), (Description: The Service Role Daemon received an LRd event which it was unable to process. This could potentially mean that a card does not have it's specified role enacted, or removed if it was taken down.), (Recommended Action: Restart the service_role_daemon process to resync all roles and replay the lost notification. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-6-CONFIG_WAVELENGTH ### Response: (Severity: 6), (Category: PLATFORM), (Description: Software failed to calculate wavelength for this tunable optic. On failure, it reread complete EEPROM and recalculated wavelength from new data. But that retry also failed. Need to configure wavelength to bring this port up.), (Recommended Action: Try to bring up the port by - Configuring a valid wavelength If that does not work then by - Optic OIR Get following output for further analysis - show tech-support ethernet interface location <> - show controller <> all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-AUTOSAVE_INIT_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: Initialization of config cli auto-save commit verifier failed.), (Recommended Action: Collect show logging output, show config failed before exiting from admin config mode, to see which config commit caused this error. Also any other suspicious error messages on console and inform technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between IOS XR bootable files and PIEs? ### Response: IOS XR bootable files with the .vm extension are used to install software when the router is booted for the first time or during a last resort disaster recovery. PIEs are packages that can be added to a running IOS XR system to provide additional functionality. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_AGENT-3-CARD_AUTH_STATUS ### Response: (Severity: 3), (Category: DRIVER), (Description: Authentication status of hardware in the specified location. If status is FAILED, the card could not be verified as a genuine Cisco product.), (Recommended Action: Please copy the error message exactly as it appears on the screen and gather the output of CLIs 'show diag eeprom-info', 'show tech-support ethernet interfaces'. Please ensure that the line card daughter board card type, board PID and serial number are not modified. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-THREAD_DETACH_FAILED ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: Packet server was unable to detach from a new thread.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: G8032-3-PORT_STATE_ACK_TIMEOUT ### Response: (Severity: 3), (Category: L2), (Description: Updates to the port states have errored for the indicated ring instance. Any further state updates on these ports cannot be sent until the error is cleared, potentially blocking important updates. It is also possible that the current state has not been correctly implemented.), (Recommended Action: Restarting the l2vpn_mgr and erp_ctrl process should resolve any network disruption due to the issue, but support should be contacted so the issue can be investigated.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR_EA_OOR-4-NP_FLOWS_OOR_GREEN ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_I2C_PHY_TM_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected I2C timeout error on PHY SFP port.), (Recommended Action: Ensure that the SFP plugged in is supported. If not, replace the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-TCAM_L2_THRESHOLD_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: The TCAM utilization for the Logical Table (LT) L2 partition on a specific LC has exceeded the provisioned warning threshold (%)), (Recommended Action: Limit TCAM Logical Table (LT) L2 usage accordingly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-2-SHMWIN_CRITICAL_ERROR ### Response: (Severity: 2), (Category: QOS), (Description: The DPA QoS EA module encountered a critical shared memory error. The message will provide further details on the error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CVAC-3-CONFIG_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: Automatic configuration from the indicated file was not fully successful. At least one error of some sort was encountered.), (Recommended Action: Inspect the suggested file and/or 'show' commands to determine what configuration was rejected and why. Manually correct the configuration, or update the source configuration file and reload the router to prompt CVAC (Cisco Virtual Appliance Configuration) to run again on the updated file.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA_TP-7-ETMM_REG_FAILURE ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: Internal error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the IOS XR System Database (SysDB)? ### Response: SysDB is a centralized in-memory database that provides a consistent view of system state and configuration. It is used by IOS XR processes to store and retrieve config and operational data. SysDB supports high availability by replicating data between nodes. It provides a schema-driven API for processes to access the data. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_DLL-7-ERR_REGISTER_GET ### Response: (Severity: 7), (Category: FABRIC), (Description: An attempt to read a Hardware register failed. This could result in inconsistent behavior of the device.), (Recommended Action: Run diags on the board and contact TAC support. If it is possible to isolate the trigger point for the read failure, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-3-SLICE_NOT_READY ### Response: (Severity: 3), (Category: L2), (Description: Slice not powered up or initialized yet), (Recommended Action: Check if all the slices of the card are powered up and initialized) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-FRR ### Response: (Severity: 5), (Category: ROUTING), (Description: The specified backup tunnel interface has changed it's FRR status.), (Recommended Action: None. This is a solicited message (by 'logging events frr-protection' \ interface configuration) and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC_CTRL-3-NO_PRIMARY_DSC_NODE ### Response: (Severity: 3), (Category: PLATFORM), (Description: After numerous retries, the system has been unable to elect an RSP node to act as the primary DSC node. Without this election complete, the system is inoperable.), (Recommended Action: This node will automatically reset in order to reattempt bootup and DSC arbitration. If this is a cluster configured system, check the physical connections for the inter-chassis control links. If the redundancy state displayed in the log indicates an unknown redundancy state, this may indicate a hardware issue with the RSP card. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-3-ECC_ONE_BIT_XFP_DATA ### Response: (Severity: 3), (Category: PLATFORM), (Description: Poller device driver Detected and corrected one bit error), (Recommended Action: Its a correctable error, no action needed. Verify no false DOM alarms for ports on corresponding poller device) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an IPv6 address on an interface in Cisco IOS XR? ### Response: To configure an IPv6 address on an interface, enter interface configuration mode and use the 'ipv6 address' command. RP/0/RSP0/CPU0:router#config RP/0/RSP0/CPU0:router(config)#interface GigabitEthernet0/0/0/1 RP/0/RSP0/CPU0:router(config-if)#ipv6 address 2001:db8::1/64 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_OUT_MEM_UCORR_ECC_ERROR_LNK0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast output memory uncorrectable ECC error on link 0), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-PLL_PTP_STATE_HOLDOVER ### Response: (Severity: 3), (Category: PLATFORM), (Description: No external reference frequency is available for synchronization, so the PTP PLL output is in holdover, maintaining the most-recent frequency to which it was locked.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-3-HOST_LINE_LOL ### Response: (Severity: 3), (Category: PLATFORM), (Description: No line lock between the NPU and DSP), (Recommended Action: Contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_SERDES_3_FAIL_1 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data serdes link 3 failure on FIA 1.), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-4-PAK_FROM_ISIS_NOT_FOUND ### Response: (Severity: 4), (Category: ROUTING), (Description: CLNS was not able to process a packet from ISIS successfully and hence dropped the packet.), (Recommended Action: This message is seen when clns was not able to process the packet as no Interface handle was found in the Database. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-TX_CH_LO_BIAS_CURRENT ### Response: (Severity: 3), (Category: FABRIC), (Description: The Tx POD detects a low bias current on a channel. The channel might not be functioning properly, and can cause cell drops, or corruption in the downstream.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-0-BOARD_LS_SILAB_CLK_FAIL ### Response: (Severity: 0), (Category: PLATFORM), (Description: Device driver detected a clock failure on some bus/port), (Recommended Action: RMA the LC ,if you see this error on every reload. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install deactivate command in IOS XR? ### Response: The 'install deactivate' command is used to deactivate a previously activated software package. The package remains on the router's storage but is no longer active. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-4-ERR_ASIC_PARITY ### Response: (Severity: 4), (Category: FABRIC), (Description: Fabricq Asic encountered a parity error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-WRITE_FAILED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The SockIO SPP plug-in failed when attempting to communicate between threads.), (Recommended Action: If any problems are seen, they may be rectified by restarting the spp process using the 'process restart spp' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_MGR-7-ERR_EVM_CREATE ### Response: (Severity: 7), (Category: FABRIC), (Description: CCSQ Event Manager create error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA_TP-3-ETMM_INIT_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Internal error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCTRL-3-CRDCNTRL_IDPROM_READ_FAILED ### Response: (Severity: 3), (Category: LIB), (Description: 'At bootup, failed to read idprom, unknown card'), (Recommended Action: 'Try another reload of the card') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-INIT_POLICERS ### Response: (Severity: 4), (Category: OS), (Description: It failed to program a flow policer during initialization.When this issue happens, it will trigger an automatic restart.), (Recommended Action: When this issue happens, it will trigger an automatic restart. Check the status of Metro IPC Server because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-3-HW_ERROR ### Response: (Severity: 3), (Category: L2), (Description: Egress Queue Manager encountered a HW error. This is a severe error and ASIC will be reset by the driver.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install verify inventory command in IOS XR? ### Response: The 'install verify inventory' command is used to verify the consistency of the software inventory on the router. It checks that the inventory database matches the actual packages installed on the router and reports any discrepancies found. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-6-REPL_RETRY ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message reporting that replication operation has failed and will be retried. This may be transient failure, replication may pass in next retry. It is possible that some configuration on the member is rejected by the management-agent. When retires exceed it will be indicated by another message (ERR_OP_RETRY_THRESHOLD)), (Recommended Action: Ensure no such configuration is present on bundle-member which can be rejected by the management-agent.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_QOSEA-3-IM_CAPS_RESYNC_FAILURE ### Response: (Severity: 3), (Category: QOS), (Description: QoS EA encountered an error during resync of QoS capsulations with IM.), (Recommended Action: Try removing the QoS policy on the interface for which this error message is printed from configuration, and then re-attach the policy to the interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DAPS-4-INIT_FAIL ### Response: (Severity: 4), (Category: IP), (Description: A failure occurred during the initialization of DAPS process. The exact reason for the failure is mentioned in the message. This could happen because of the following reasons. 1) A problem in allocating local resource because of memory shortage or software error. 2) Problem in initiating connection to an external/dependent module either because the external module is not ready or a race condition has occurred. 3) Software error either in local or external module.), (Recommended Action: System will retry to start the process and no user intervention required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-6-RP_ISOLATION ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message indicating that target RP has transitioned into RP isolation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-6-ETH_SERVER_CONNECT_STATUS ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that DRP-REDDRV's connection to the eth_server process status (trying to connect, connected or disconnected) and only when connected DRP-REDDRV is capable of sending & receiving heartbeats or arbitration messages), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_MPLS_EA-3-UPDATE_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An updation error has occured for MPLS Forwarding Information Base.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN-4-FIB_CONNECTION_FAILED ### Response: (Severity: 4), (Category: L2), (Description: SPAN EA has failed to reconnect with the Forwarding Information Base (FIB) after the connection went down. Traffic may not be mirrored to the correct destination. Use 'show monitor-session status' to determine which interfaces are affected.), (Recommended Action: This could be a timing issue and so issuing a 'process restart span_ea' and/or 'process restart fib_mgr' on the affected nodes will trigger a new connection attempt from the SPAN side. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-3-STATS_SHM ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: IP Netio library encountered failure while operating on the shm stats information.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-RP_BIOS_BOOT_INFO_ERR ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC driver failed to access the CPU Complex FPGA registers to get the information about which BIOS SPI flash was used to boot the running BIOS. This information is used by the output of 'show hw-module fpd', due to this failure, the output of this command will not show current running FPD info for the Backup BIOS image if the Primary BIOS was corrupted.), (Recommended Action: Restart the ccc_driver process will allow ccc_driver to re-read this information from the CPU Complex FPGA.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR backup tunnel timers feature? ### Response: The MPLS TE FRR backup tunnel timers feature allows the configuration of hold <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-1-ERROR_HW_ACCESS ### Response: (Severity: 1), (Category: FABRIC), (Description: Ingressq Driver encountered an error during access to the ASIC. The error may have been caused because of expected or unexpected software and hardware errors. In case, the error is a hardware error, Ingressq driver will reset the ASIC to recover.), (Recommended Action: If the error persists, please contact TAC suppport.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-3-LC_BAD_VRM_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that LC power-up failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-6-VERIFY_MSG ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-3-REG_PM_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The function call to pm_fault_register_device returned fail), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-RX_ALARM_LOF_SYNC_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: The BITS receiver has detected OOF defect for incoming signal. For T1 mode OOF is declared when out of every four frame bits two or more frame bits are received in error. For E1 mode OOF is declared when three consecutive incorrect FAS is received. Also for E1 mode(CRC-4 framing) OOF can be declared when 915 or more CRC blocks out of 1000 are received in error. Additionally for E1 mode(CAS signalling) OOF can be declared when two consecutive multiframe alignment words are received in error or, for a period of one multiframe, all bits in timeslot 16 are zero.), (Recommended Action: 1) Ensure framing format on port matches framing format on the line. 2) Configure to other framing format to check if error clears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-NP_INIT_FAILURE ### Response: (Severity: 0), (Category: PLATFORM), (Description: NP Persistent Initialization failure Indicates a problem with the Network processor on the LineCard.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_1_PKT_MINLEN_ERR_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet minimum length error on NPU-1 interface on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you configure an IP SLA operation in Cisco IOS XR? ### Response: To configure an IP SLA operation in Cisco IOS XR, use the 'ipsla' command followed by the operation number and type (such as ICMP echo, UDP echo, or TCP connect). You can also configure the frequency, threshold, and reaction conditions for the operation. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_SYSDB_GET ### Response: (Severity: 3), (Category: ROUTING), (Description: A sysdb error occurred.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-BF_MBE_ERR_FIA11 ### Response: (Severity: 3), (Category: PLATFORM), (Description: FIA11 burst FIFO multi-bit error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-3-LSR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: bfm encountered an error and is not able to recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-I2C_FAILURE_SET_LED ### Response: (Severity: 3), (Category: PLATFORM), (Description: An I2C failure occurred while trying to set one or more of the alarm card LEDs.), (Recommended Action: Try doing restarts of below process admin process restart envmon loc <>. admin process restart i2c_server loc <>. Location is from the node on which this ios_msg is seen. If the issue still persists collect required_info) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-1-BACKUP_READY ### Response: (Severity: 1), (Category: HA), (Description: RMF has determined that the backup process groups on the specified card are ready to take over as primary if it needs to.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_CLIENT-7-TOO_LONG_FEATURE_NAME ### Response: (Severity: 7), (Category: OS), (Description: Too long feature name is specified), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_FPOE_DB_UCORR_ECC_ERROR_LNK0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast FPOE uncorrectable ECC error on link 0), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_SYSDB ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB encountered a Sysdb communication failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOSHAL-6-BUFFER_CARVE_MODE ### Response: (Severity: 6), (Category: PLATFORM), (Description: 'Any change in Buffer carve mode requires the LC to be rebooted to ' 'take effect.'), (Recommended Action: hw-module location reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-3-BUS_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: SPA ERR_L interrupt is asserted by SPA when SPA bus protocol violation happens. This error happens mostly when there is an issue with hardware itself. The SPA reset is not going to recover the problem, hence SPA put into FAILED state.), (Recommended Action: Replace SPA hardware If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PM-3-SIZE_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The size of received buffer is less than the required size. This will cause degraded perforamce in IPC calls.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-NOSELF ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal error occurred. An interface was not fully initialized when an OSPFv3 related event occurred.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospfv3 - show ospfv3 interface - show ospfv3 trace all - show running-config) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-4-CONNECT_WARN_AN_NOT_ENABLED ### Response: (Severity: 4), (Category: SERVICES), (Description: 'autonomic connect will be enabled only after AN is enabled globally, ' 'and on this interface'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-4-PROVIDER_BRIDGE_MISMATCH ### Response: (Severity: 4), (Category: L2), (Description: STP on this router has been configured in provider-bridge mode, but has been connected to a router sending BPDUs in non-provider-bridge mode (or vice versa). This is a misconfiguration and could result in loops in the network.), (Recommended Action: Examine the STP configuration on this router and on the router to which it is connects on this port. Ensure that both routers have the same provider bridge mode configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-CLEAR_AFTER_SWITCHOVER ### Response: (Severity: 3), (Category: ROUTING), (Description: Service-Layer had only partially replicated its database before switchover. The service-layer will return SL_INIT_STATE_CLEAR on the next connection indicating its database is empty.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON_EA_TEST-3-ERROR ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-EVENT_CONN_GET_FD_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to retrieve the file descriptor associated with the specified service. This is an internal error.), (Recommended Action: Consider restarting the IS-IS process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-4-CONN_SETRETRY ### Response: (Severity: 4), (Category: ROUTING), (Description: CLNS failed to set the linear retry period for connecting to sysdb. We set the retry period in order to avoid immediate reconnection attempt from clns to sysdb server when the latter restarts. This prevents clns from blocking on sysdb and cause any traffic drop.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAA_BASE-4-WARNING ### Response: (Severity: 4), (Category: SECURITY), (Description: An internal software error has occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CMPP-4-ERR_DEBUG ### Response: (Severity: 4), (Category: INFRA), (Description: CMPP encountered an error using the debug service. The error message describes what operation has failed and why it failed. The error could be caused by low memory resource or programming error.), (Recommended Action: In many cases, CMPP will recover by itself. If it does not then restarting the process may help. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_12_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD_NETIO_DLL-3-TPA_INIT_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Unable to init TPA.), (Recommended Action: Please capture show proc output and show logging output - 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFL-6-INFO_PARAM ### Response: (Severity: 6), (Category: PLATFORM), (Description: A file management parameter has been changed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC_CTRL-6-ISSU_RELOAD ### Response: (Severity: 6), (Category: PLATFORM), (Description: An ISSU upgrade is in progress and this node requires a reload. When the upgrade is complete, this node will be restarted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_AMCC2035-7-INFO ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message occured due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-GEN_ERR2 ### Response: (Severity: 3), (Category: ROUTING), (Description: General error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-3-ERR_BCDL ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID Server encountered the annunciated BCDL error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_DLL-3-RESET ### Response: (Severity: 3), (Category: FABRIC), (Description: CCSQ, cpuctrl net interface encountered a CRC/Sync Error. This will result in the PIO or CDMA failure.), (Recommended Action: If it is possible to isolate the trigger point for the sn link error, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTQ0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-4-NO_IP_ADDRESS ### Response: (Severity: 4), (Category: SECURITY), (Description: There is no IP address configured for the specified interface.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-GET_MYNODEID_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_FAN_MISSING ### Response: (Severity: 2), (Category: PLATFORM), (Description: The CPT 50 Panel Fan Unit is Missing (SAT_FAN_MISSING) alarm is raised when the fan-tray assembly is not present in the CPT 50 panel.), (Recommended Action: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_AB_INTR_IFIFO_ORUN1_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_AB_INTR_IFIFO_ORUN1 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-FIFO_1_OFLOW_NPU2BR_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: FIFO-1 NPU to bridge instance-0 overflow.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: G709-4-ALARM ### Response: (Severity: 4), (Category: L2), (Description: The specified G709 Alarm has been declared or released.), (Recommended Action: Recommended action is to repair the source of the alarm.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-3-IMDR_CONN_ERROR ### Response: (Severity: 3), (Category: FABRIC), (Description: A problem was encountered while trying to connect with the imdr process. There are a few steps involved while connecting and the error message indicates which step in the process failed and the reason that it failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-SUSPENSION_STOP ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-5-AUTH_FAIL ### Response: (Severity: 5), (Category: L2), (Description: Authentication was unsuccessful.), (Recommended Action: Recommended to check the configuration on both dot1x peers and connectivity between the authenticator and the AAA server.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_PW_INTR_LEN_DROP_CNT_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_PW_INTR_LEN_DROP_CNT_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PM-3-ERROR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: CRS Platform Manager encountered an initialization error A reason text will be supplied to describe the error.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect 'show log location ' output, and 'show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_NB_SERDES_0_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data north bound serdes link 0 failure on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-3-ERROR_SYSDB_SET ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-NODE_RESET_ALARM ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the Shelf Manager or Platform Manager encountered a critical alarm for the node specified. It will attempt to reset the board which sends the alarm.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-2-RESET_SP_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: The hard reset of sp was unsuccessful due to the mentioned reason.), (Recommended Action: Reset of SP is typically initiated when that SP needs to be hard reset. If that fails, only a software reset be initiated. Please collect 'show cctl trace shelfmgr loc' from the node on which this ios-msg is seen.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-6-MBI_DOWNLOAD_COMPLETE ### Response: (Severity: 6), (Category: INSTALL), (Description: Status information for completion of MBI download.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_LQ_PKT_LEN_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue packet length error on XAUI 0 LQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure NTP in IOS XR? ### Response: To configure Network Time Protocol (NTP), use the 'ntp' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#ntp server 192.168.1.101 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON-3-EA_LTRACE_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ltrace initialization failed within EA. Ltraces may not be printed), (Recommended Action: No action is required. Process will be automatically restarted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON-3-EA_DEBUG_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Debug initialization failed within EA. Debugs may not be printed), (Recommended Action: No action is required. Process will be automatically restarted.Else try restarting manually. Get the job id 'show processes afmon_ea location <>' 'process restart location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE policy-class feature? ### Response: The MPLS TE policy-class feature allows the mapping of traffic to specific TE tunnels based on match criteria such as access lists, packet length, or QoS parameters. Policy-classes define the matching rules and the tunnels to which the traffic should be mapped. This provides granular control over traffic forwarding into TE tunnels. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the inventory manager process in IOS XR? ### Response: The inventory manager process maintains an inventory of the cards installed in the system, including their current state and other relevant information. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APPMGR-6-DOCKER_DAEMON_STOPPED ### Response: (Severity: 6), (Category: INFRA), (Description: The Docker daemon has stopped. Docker related functionality will be unavailable.), (Recommended Action: Contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. if user did not stop the docker daemon.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_10_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to enable BGP graceful restart for MPLS L3VPN? ### Response: To enable BGP graceful restart for MPLS L3VPN, use the 'graceful-restart' command in BGP configuration mode. router bgp 65000 bgp graceful-restart <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM_LIB-6-INVALID_REQUEST_ID ### Response: (Severity: 6), (Category: OS), (Description: There is miuse of library.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-MFI_FREE_INFO ### Response: (Severity: 6), (Category: ROUTING), (Description: Important information about freeing labels. No reason fro alarm unless the message is displayed periodiaclly for several minutes), (Recommended Action: If the message is displayed periodically for several minutes, then restart ISIS. If the message continues to be displayed restarting for several minutes, then contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_2_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Rx power less than or equal to the low Rx power alarm threshold. The QSFP+ is the pluggable optics on the line cards. The Rx power threshold values are read from the QSFP+.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ITCAM-4-usage_warning ### Response: (Severity: 4), (Category: PLATFORM), (Description: There are not enough free tcam entries to meet the allocation request in the current region. However, there are un-used entries in other regions that can be obtained by this request through reloading the linecard.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_CMD-3-NOMEMORY ### Response: (Severity: 3), (Category: INSTALL), (Description: The requested operation could not be accomplished because of a low memory condition.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ETHER-6-MODE_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: This informational message indicates that PLIM interface mode changed to 'LAN' or 'WAN' from CLI.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_RP-3-ERR_INFO_TBM ### Response: (Severity: 3), (Category: PLATFORM), (Description: An internal software error during VPNV4 GTRIE processing by FIB on the RP. This may be a transient case.), (Recommended Action: Please collect the following info: dumpcore running process location The 'node' is the location where this IOS message was observed. The 'proc-name' is the process which generated the message. show version show platform show logging admin show install active) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-5-ERR_CONT ### Response: (Severity: 5), (Category: L2), (Description: This message indicates an error occurred beyond which execution of the pse_driver may continue, attempting to effect recovery or work-around internally, minimizing loss of information/functionality.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-STANDBY_PROXY_SPAWN ### Response: (Severity: 7), (Category: HA), (Description: Multiple attempts to spawn a copy of the checkpoint proxy for this application on the standby were done, and the attempts have been stopped.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-SYS_CALL_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: QNX OS System call failed.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-4-WARN_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of CDP. CDP will restart and this should resolve the problem.), (Recommended Action: CDP will try to recover automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TOPAZ_PFI-3-SET_GLOBALS_MMAP_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Memory map api failure in Platform PFI api. The returned error code should indicate the reason for the failure of the api. This is a transient error in the system likely due to low mem condition etc. The impact to system is minimal except that some global counters are not set. The client calling this api could retry it or handle it accordingly. If the issue is seen persistently, initiate the recommended action.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_AIS_DEMB ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-PERF_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-1-ERR_HW_HEALTH_MON ### Response: (Severity: 1), (Category: FABRIC), (Description: The fabric driver verifies the hardware interfaces between the various components on the fabric board. This is done on cold start (POST) and periodically there after. This message is annunciated when any of the tests fail.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-SRV6_INIT_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred whilst initialising the SRv6 module. This could be caused by failure to allocate resources or by errors when calling the sidmgr.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-1-DOP10_OFFLINE_CARD_RELOAD_ACTION ### Response: (Severity: 1), (Category: OS), (Description: DOP10 OFFLINE event occured. Reload lc required.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-S2L_UPDOWN ### Response: (Severity: 5), (Category: ROUTING), (Description: The specified interface destination has changed operational state.), (Recommended Action: None. This is a solicited message (by 'logging event sub-lsp state' \ interface destination configuration) and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-NOTIFYTWICE ### Response: (Severity: 4), (Category: SNMP), (Description: The given MIB attempted to register more than once for the given MIB notifications. This should have no detrimental effect on the behavior of the system.), (Recommended Action: Restart snmpd process.if still noticed this message check the state of snmpd process 'show process snmpd' and contact technical support representative. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_CHAR_ALIGN_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-0 char alignment error on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_0_XAUI_PLL_LOCK_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: NPU-0 XAUI PLL not locked on bridge instance-1.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-7-ADJ_RES_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Could not adjust resource), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_PLIM_SB-3-SW_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An internal software error has occurred for the specified SPA.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-BADLENGTH ### Response: (Severity: 4), (Category: ROUTING), (Description: The system received an OSPF packet with a length field of less than normal header size or inconsistent with the size of the IP packet in which it arrived. This indicates an error in the sender of the packet.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-4-MAC_LIMIT_PW_SHUT ### Response: (Severity: 4), (Category: L2), (Description: Number of MAC addresses in the pseudowire has reached the configured maximum. Since 'shut' action has been configured for MAC limit event on the port, it has been shut down.), (Recommended Action: Manual intervention is required to bring the port up again. Please use 'clear l2vpn bridge-domain' command to bring the port up.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-FM_FEAT_PROCESSING ### Response: (Severity: 3), (Category: OS), (Description: An internal fm feature registration function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-2-RC_INIT_ERR ### Response: (Severity: 2), (Category: ROUTING), (Description: The route collapse IPC could not be initialized), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPP-3-RSI_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: MPP (Management Plane Protection) failed to bind to RSI (Route Space Infrastructure) to get the vrf information for each interface.), (Recommended Action: Restart the impacted process and see if the issue persists. If the issue recurs, then issue the commands 'show running-config control-plane' and 'show mgmt-plane trace client both' to gather data and provide the gathered information and the exact error to the Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_2_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Rx power greater than or equal to the high Rx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Rx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TSEC-6-DRIVER_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The particular operation mentioned in the message gave an informative message. This is not a failure.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_EA-3-NO_STATS ### Response: (Severity: 3), (Category: L2), (Description: The MFR EA interface stats collection initialization failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCT_MA-3-MERGE ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: The merge keyword must be configured to combine same-direction service-polices from different dynamic-templates for a session. This helps avoid any inconsistencies in seriver-policy.), (Recommended Action: Add the merge keyword to all service-policies that are to be combined. If issue persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_SHMEM ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal Error: Shared memory error description.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_NI_INTR_CRC_ERR3_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_NI_INTR_CRC_ERR3 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-GRUB_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: GRUB running on the indicated card is reporting an error condition.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLDP_POLICY-3-ORA_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: There was an internal error in the routing policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option dynamic attributes feature? ### Response: The MPLS TE path-option dynamic attributes feature allows certain LSP attributes to be specified for a path-option without configuring an explicit path. LSP attributes that can be specified include bandwidth, priority, affinity, and setup and hold priorities. This provides a way to influence the dynamic path calculation with additional constraints. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-NOT_A_MANAGEMENT_NODE ### Response: (Severity: 7), (Category: INSTALL), (Description: A function available only on management nodes was called on a non-management node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TSEC_SPP-3-RX_PKT_DROP ### Response: (Severity: 3), (Category: PLATFORM), (Description: TSEC driver on CPU received an errored packet. The packet was dropped.), (Recommended Action: The issue might not be very significant if it happened only once. If the message recurs, Copy the error message exactly as it appears on the console or in the system log. Issue the show spp ioctrl location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show spp ioctrl location output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEXMGR-2-HW_STRAP_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: PCIE device hardware strap error), (Recommended Action: Please reload the board using the following command: 'reload location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_LOCAL-3-NULL_POINTER ### Response: (Severity: 3), (Category: L2), (Description: A Null pointer is recieved at particular line and function in question. This should not happen in normal scenario. This message would indicate reason as well.), (Recommended Action: This error indicates a problem in the code and cannot be easily recovered from. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WDMON-3-PM_HEARTBEAT_MISS ### Response: (Severity: 3), (Category: INFRA), (Description: Sysadmin process manager liveness check failed. Sysadmin will reboot if the system is unable to correct this condition on its own.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_IM_CAPS_DATAPATH_CONTROL ### Response: (Severity: 3), (Category: ROUTING), (Description: Error while sending dpc message.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-7-EDM_INTERNAL ### Response: (Severity: 7), (Category: OS), (Description: The server's EDM has either failed a function that expected to succeed, or has got into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_DLL-2-ERR_EIO_TRAIN ### Response: (Severity: 2), (Category: FABRIC), (Description: Repeated attempts to train the EIO links to the neighboring Asic have failed. No further attempts to retrain the link will be made.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-WARN_MAC_IF_SES_THRESHOLD_EXCEED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions from a particular MAC address on the given access interface has exceeded the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HORSE-2-ERR_RC ### Response: (Severity: 2), (Category: PLATFORM), (Description: Error in HORSE operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SYNC-7-PTHREAD_API_ERROR ### Response: (Severity: 7), (Category: OS), (Description: Pthread API returned an error), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGPTE_LIB-4-INVALID_TLV ### Response: (Severity: 4), (Category: ROUTING), (Description: Failed to send data due to the limitation of the buffer size. This is an internal error. It requires to reduce the number of interfaces.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHOW_VERSION_CMD-7-IFMGR_BIND ### Response: (Severity: 7), (Category: PLATFORM), (Description: A Version Manager CLI command was unable to bind to the interface infrastructuree from which it obtains information. The command will not contain all expected information.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How is the IS-IS router ID determined in Cisco IOS XR? ### Response: By default, the IS-IS router ID is automatically generated based on the highest IP address configured on the router's loopback interfaces. It can also be manually configured using the 'router-id' command under the IS-IS instance configuration mode. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-3-HSSD_GET_DATA_FAILED ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to read data from the packet HSSD area.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-2-DEV_VERSION_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Interrupt controller driver version is not compatible with the hardware version.), (Recommended Action: Upgrade the Interrupt controller FPGA image using FPD procedure. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-4-PM_CLEANUP_FAILED ### Response: (Severity: 4), (Category: INFRA), (Description: The SLA Profile Manager failed to cleanup correctly. It will exit anyway, and no further errors should be seen.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_TDM-7-NO_TRANSLATOR ### Response: (Severity: 7), (Category: HA), (Description: A required translator was not loaded.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APPMGR-3-DOCKER_RM_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The IOS-XR appmgr has errored or failed while trying to remove a docker container. This means the underlying docker rm operation has failed, and that the docker container specified may continue to exist. This may lead to conflicts if the application is activated again before this is resolved.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-SYSDB_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured while communicating with sysdb.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT_SWITCH-3-LINK_FAIL_6 ### Response: (Severity: 3), (Category: PLATFORM), (Description: PUNT link has failed.), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-SOCKET ### Response: (Severity: 3), (Category: ROUTING), (Description: The above specified socket operation failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-GI_FILES_CREATED ### Response: (Severity: 6), (Category: HA), (Description: Information captured by various modules and stored in bootflash during a previous reset has been moved to hard disk.), (Recommended Action: Examine the dump information for possible root-cause for a previous reset. Use the wd_test utility.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_3_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_LAS ### Response: (Severity: 4), (Category: L2), (Description: IPV6CP encountered an error using the LAS API. The error message describes what operation failed. This may be a resource starvation problem or an internal programming error.), (Recommended Action: Restart the local ipv6_ma process and/or the ppp_ma process. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_3_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_COM_IFIB-7-DEBUG_INIT ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when initializing debug. The facility to debug the component may not work.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_BAG ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the Bag Client library. The error message describes what operation has failed and why it failed. The most likely reason for this a low memory condition but the error could also be caused by a programming error. The error will affect PPP MA's ability to provide operational management data, but won't otherwise affect PPP MA's operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_7_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias less than or equal to the low laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_RIB ### Response: (Severity: 3), (Category: ROUTING), (Description: Error encountered by RIP during interaction with RIB.), (Recommended Action: These messages are expected during RIB process restart. In all other cases, please contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_VLAN_EA-3-MAX_HSRP ### Response: (Severity: 3), (Category: PLATFORM), (Description: HSRP ID is greater than 255, not supported. Configure HSRP ID less than 255.), (Recommended Action: Please capture the complete error log. Please check the data sheet for the supported configuration. Please contact TAC for any support on this) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR ensure software package integrity during installation? ### Response: Cisco IOS XR ensures software package integrity during installation through the use of digital signatures and checksum verification, preventing the installation of tampered or corrupted packages. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-ACTION_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: A user requested install operation has errored and failed. The operation cannot proceed further as there is no active RP on which the install operation was successful.), (Recommended Action: If possible, the IOS-XR install infrastructure will have recovered the system to its state before issuing the command that triggered this operation. Otherwise, the following recovery options are available: 1. Abort the operation to return to its previous state. This will not cause XR processes to restart or nodes to reload. 2. Reboot the system to return to the committed state. Note further that: - The install operation history records full details of the operation, including its outcome on every node on the system, and the final state of the system. - If any of the recovery options is not available for the current failure, it will be rejected when attempted (with no impact on the system). So it's always safe to try the preferred recovery mechanism.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-INTERFACE_DATA ### Response: (Severity: 3), (Category: ROUTING), (Description: CLNS was unable to look up local interface information. As a result the system may not be able to send/receive ISIS packets over this interface. This may be due to problems with either CLNS or the forwarding infrastructure.), (Recommended Action: Please contact cisco-support with the required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-SI5345_CLOCK_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Si5345 clock failure/success for the given serdes towards RSP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-6-ERR_ASIC_GENERIC ### Response: (Severity: 6), (Category: FABRIC), (Description: Fabricq encountered an interrupt that has exceeded its threshold value. Software takes appropriate action to log and fix the error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp update-delay' command in IOS XR BGP configuration? ### Response: The 'bgp update-delay' command is used to configure the maximum time that BGP will delay sending updates to neighbors after the BGP process starts. By default, when the BGP process starts, it immediately sends out updates to all neighbors. In a large network, this can result in a significant amount of processing on the neighbors. The update delay allows the BGP process to stagger the sending of updates, reducing the processing load on the neighbors. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_AGORA_ALM_TYPE_THREE ### Response: (Severity: 2), (Category: PLATFORM), (Description: AGORA type three alarm.), (Recommended Action: If the problem persists, call your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does the sporadic scheduling algorithm work in IOS XR? ### Response: With sporadic scheduling, a thread is assigned a normal priority, low priority, budget time, and replenish interval. The thread runs at normal priority until it exhausts its budget, then drops to low priority. After the replenish interval, the budget is restored and the thread returns to normal priority. This allows important threads to execute while preventing CPU starvation. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_0_XAUI_RDY_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: NPU-0 XAUI not ready on bridge instance-2.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KIM-6-VIRTUAL_IP_CHKPT_RESTORE ### Response: (Severity: 6), (Category: INFRA), (Description: Virtual IP addresses known to kim are stored in a Checkpoint database, so that on process restart, kim is able to remove any virtual IP addresses that may have been removed while kim was not running. If the Checkpoint restoration fails, then kim will be unable to clear stale addresses from Linux.), (Recommended Action: No action should be required. Stale addresses on Linux lo:virtual-ip interfaces that do not correspond to a virtual IP configured in XR can be removed, if desired.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-STARTUP_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: locald process failed to startup properly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_14_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_14 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KENSHO_GL-3-LTRACE_INIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ltrace initialization failed. This may be a program level error. The failure will cause the Procmgr process to restart.), (Recommended Action: The Procmgr process will automatically respawn up to a fixed number of times. Verify the process is running: 'show process procmgr location <>' If it is still not spawned contact support with the required info. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XFP-2-DEV_XFP_OPTICS_PORT_UNSUP ### Response: (Severity: 2), (Category: PLATFORM), (Description: An XFP Module not supported for the port error was detected during XFP initialization. An XFP Module not supported for the port error is reported when Optics is not supported on the port. The XFP is the pluggable optics on the line cards. XFP initialization may happen when linecard boots up, XFP OIR and line card process restart.), (Recommended Action: Verify that the XFP Module is supported for the port. Replace the XFP with a working one (if any) to isolate bad optics. Check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the command 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-6-INSTALL_RESTART_XLNCD ### Response: (Severity: 6), (Category: INFRA), (Description: The Install component has detected a change within nb.bpf or the XLNCD binary. The following will happen, all capture sessions deleted, all EXI interfaces deleted, and all 'to_xr' interfaces will be deleted, then the XLNCD process will restart.), (Recommended Action: Please wait for XLNCD to restart.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-3-SYSDB_INIT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Sysdb initialization failed during PFM process startup. This means that the card reset disable feature may not work on this node as per configuration.), (Recommended Action: Manually restart pfm_node process on the node and see if the Sysdb initialization is successful during this attempt.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MOFRR_FLOW-3-DETECT_LOSS_BACKUP ### Response: (Severity: 3), (Category: ROUTING), (Description: LC control plane detected that either no traffic coming or traffic loss is occurred on backup path. Data plane should switch over to the MoFRR primary path already. But somehow the traffic switchover notification message sent from data plane has been lost from NP on the way to LC CPU. With this detection, control plane will re-sync with data plane on MoFRR route.), (Recommended Action: It is a self-recovery detection. There is no extra action needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-6-SERVICE_UNAVAIL ### Response: (Severity: 6), (Category: OS), (Description: Service state has become unavailable. SSM process will try a recovery action. They are not necessarily critical errors but need investigation by DE.), (Recommended Action: Collect system logs. Collect show tech ssm. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_CLI-7-INVALID_ARG ### Response: (Severity: 7), (Category: HA), (Description: An argument was passed with an invalid value.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STANDBY-3-ERR_NO_MEM ### Response: (Severity: 3), (Category: IP), (Description: HSRP was not able to allocate the memory that it needed to complete the operation. HSRP functionality may be reduced until the problem is resolved.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-SAT_CPM_INIT_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to failure on register with CPM for satellite communication. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_8_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-XAUI_1_FRAG_ERR_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: XAUI interface to NPU-1 reported fragmentation error on TX side on bridge instance - 2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_EXEC-3-LIST_INSTANCE_ERROR ### Response: (Severity: 3), (Category: L2), (Description: Unable to list all instances, this may be due to node down or program level error.), (Recommended Action: Try to rerun the CLI , if it fails again please contact support If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-TIMER ### Response: (Severity: 3), (Category: ROUTING), (Description: FIB internally manages sone activity using 'timers'. An error occurred while initializing timers. The process will attempt to recovery by restarting. If the restart count is excessive then the node may reload. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHER_CTRL-3-IF_CONFIG_OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPGAMGR-3-LTRACE_OPEN_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Due to an error in the ltrace initialization routines, the init failed. This may be due to other problems on the system (is ltrace running?).), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ACL-6-IPACCESSLOGNP ### Response: (Severity: 6), (Category: ACL), (Description: Packet matching the log criteria for the given access list was detected. These messages are issued when the IP protocol type is other than TCP, UDP and SCTP. This message is seen for the first match and for each match after the hit count is greater than 0x7FFFFFFF(2147483647).), (Recommended Action: This is information only message, no action required No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RLOGIND-3-ERR_OPEN ### Response: (Severity: 3), (Category: IP), (Description: An unexpected error occurred when RloginD tried to open a VTY character special file.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_LIB-3-REPLY_MSG_SENDING ### Response: (Severity: 3), (Category: INSTALL), (Description: An error occurred while sending a reply LWM message to a client. It can be a data or an error number reply.), (Recommended Action: Please check the error message and take corrective actions if necessary. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-RPF_REDIRECT_SN_NO_BW ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPP_TCAM_RM-3-NONFATAL_ERR ### Response: (Severity: 3), (Category: L2), (Description: This is a error message in the CPP TCAM RM to indicate anomalies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temporary situation is resolved. *RECUR*), (Recommended Action: *SH_CMD show controllers pse qfp infrastructure tcam resource-manager usage location < > * *SH_CMD show controllers pse qfp infrastructure tcam resource-manager error parity location < > *) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-6-LC_READY_INFO ### Response: (Severity: 6), (Category: OS), (Description: Linecard is in ready state.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of configuration templates in IOS XR? ### Response: Configuration templates in IOS XR allow you to define a common set of configuration commands that can be applied to multiple entities, such as interfaces. This promotes consistency and reduces configuration errors. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-EVM_CREATE ### Response: (Severity: 3), (Category: HA), (Description: An internal error was detected when creating Event Manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-6-DEACTIVATE_DONE ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Package deactivate requested on this satellite has completed. Run 'show nv satellite status' for more information.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-RDB_NO_LSA ### Response: (Severity: 3), (Category: ROUTING), (Description: OSPF found inconsistency between a database entry and its associated path.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTEG_SWITCH-2-LINK_STATE_CHANGE ### Response: (Severity: 2), (Category: PLATFORM), (Description: When the process starts, port state oscillate between up and down and finally the port state will become up. While configuring also port link state change message information displayed. Except the above two scenarious, if port state change occurs please contact TAC support.), (Recommended Action: Please restart the process 'process restart integSwitch' and verify the port state 'show controller switch ports location all'. If it not recovered please collect (admin)Show tech-support control-ethernet and contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON-3-ERR_EVENT_ATTACH ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to attach event to event manager.), (Recommended Action: No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*.Else try restarting manually. Get the job id 'show processes afmon_ea location <>' 'process restart location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-INVALID_64K_INPUT_SYNC_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: The 64k composite clock signal has been invalidated possibly due to loss-of-signal condition or AMI violations.), (Recommended Action: 1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 64kHz + 8kHz Japanese timing signal(defined in G.703 Appendix II.1) is applied at input port.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-IN_DEP_LIST ### Response: (Severity: 6), (Category: HA), (Description: This message is emitted if the misbehaving process is one that wdsysmon depends on. It will not be terminated.), (Recommended Action: The command 'show watchdog trace' will display additional information about the process. Forward this information to technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-3-CAN_INIT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The shelfmgr could not initialize its CAN Bus Interface, due to the reason mentioned in the message. The shelfmgr will attempt to recover by restarting up to 5 times. If the issue persists, the RSP will be reset which will cause the standby RSP to take over as active.), (Recommended Action: None, since the system will perform recovery action automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ACL_PARSE-7-ERR_THREAD_MUTEX_LOCK ### Response: (Severity: 7), (Category: ACL), (Description: A mutex is used to protect the ACL and Prefix List caches. An attempt to lock a mutex failed with the error reported.), (Recommended Action: Abort the configuration operation and restart the parser server.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIO-7-ERR_REGISTER_GET ### Response: (Severity: 7), (Category: PLATFORM), (Description: The EIO library encountered the annunciated register access error. This could result in inconsistent behavior of the device/system.), (Recommended Action: Run diags on the board. If it is possible to isolate the trigger point for the read failure, collect all the necessary info (condition) that caused the error. Reload the MSC to avoid inconsistent behavior of the system because of this read failure. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMA-3-INCORRECT_BW_UPDATE ### Response: (Severity: 3), (Category: L2), (Description: When the indicated member link was deactivated, group bandwidth could not be updated correctly as decrementing the link's bandwidth would have made the group bandwidth to go below zero. Group bandwidth is now made zero.), (Recommended Action: Check the group and member interface status. Verify that the group bandwidth is correct now. If not, shut all the members of the group and then no shut all the members to bring back the group bandwidth to correct value.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-2-SFP_XCVR_TYPE ### Response: (Severity: 2), (Category: L2), (Description: This message indicates that the unsupported SFP type is inserted.), (Recommended Action: - Check the SFP, make sure it is CISCO certified - Insert the supported SFP types) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_MISSNAME ### Response: (Severity: 4), (Category: SYSDB), (Description: The command entered requires an item name and one was not supplied.), (Recommended Action: Use the help command to determine the correct usage for this command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-INSTALL_ISSU_AUTO_ABORT_TIMER_NOT_FOUND ### Response: (Severity: 4), (Category: INSTALL), (Description: Auto-abort timer was expected (per user options specified) but not running after RUN phase.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSMGR-3-NOMEM ### Response: (Severity: 3), (Category: OS), (Description: The client library has failed to allocate the required amount of memory.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-PORT_DOWN_WITH_REMOTE_FAULT ### Response: (Severity: 3), (Category: INFRA), (Description: Port is down due to Remote Fault.), (Recommended Action: Check for port status, connectivity and note the trigger To recover reset the switch.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-IDB_DELETE ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process failed unexpectedly to delete an interface descriptor block from the idb WAVL tree.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA_CAPI_SERVER-3-IOFPGA_RD_WR_CHK ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_HFR-7-INFO_SHM ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered a change in the shared memory region parameter.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_OUT_MEM_UCORR_ECC_ERROR_LNK3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast output memory uncorrectable ECC error on link 3), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-5-CLOCK_INTERFACE_PORT_0_SENDING_AIS ### Response: (Severity: 5), (Category: PLATFORM), (Description: When no external clock source is available, this status propagates to BITS output ports in T1 and E1 modes. When an external source is qualified, this alarm will be cleared.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_AGENT-3-BACKUP_BIOS_LOADED ### Response: (Severity: 3), (Category: DRIVER), (Description: The Backup BIOS images on BIOS SPI Flash has been loaded on the indicated card. The output of 'show hw-module fpd' will show the affected images with BACK IMG state. This can happens when Primary BIOS Flash is corrupted, so it fallback to load the backup image set to recover from the failure.), (Recommended Action: Although the system will continue to run, the backup image set might be of older version and it might have known issues that have been fixed on latest version. So it is critical to address the problem as soon as possible. The output of 'show hw-module location fpd' will identify the image with the problem with NEED UPGD state and it will have missing Programmed version. To correct the problem, use the 'upgrade hw-module location fpd ' command to re-program the FPD image and power-cycle the affected card for BIOS to load with the upgraded image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-BOOT_RECOVERY_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: TBD.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAA-3-DLLMAIN_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Error message from DLL initialization module), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-7-FAILOVER_ENABLED ### Response: (Severity: 7), (Category: HA), (Description: Redcon has notified the card failover has been enabled by the configuration.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-6-NP_DOWN_EVENT ### Response: (Severity: 6), (Category: PLATFORM), (Description: Process fib_mgr receives NP down event notification at the linecard. This is for information and event timestamp logging purpose only. No additional action is required.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_14_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_14 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTQ1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-6-BEST_MASTER_CLOCK_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: The best master clock available to PTP has changed.), (Recommended Action: This message is for information only, no further action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_XRV9K_NETIO_LIB-4-FINT_IDB_NOT_FOUND ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The FINT IDB is not yet created in NetIO. This could be a transient condition.), (Recommended Action: Please capture the following information and if traffic loss also is being observed: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. show logging show proc blocked) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPA_1P_OC192-6-OPTICS_INSERTION ### Response: (Severity: 6), (Category: L2), (Description: Optics module has inserted), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_0_EGR_Q_ERR_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Egress queue error on NPU-0 interface on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-GWCTX_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: A software error has occurred whilst trying to initialize the gateway context database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_UPD-3-BACKUP_BIOS_LOADED ### Response: (Severity: 3), (Category: INFRA), (Description: The Backup BIOS images has been loaded on the indicated card. This can happen when process detects that the Primary image is corrupted, and the HW fallbacks to load the backup image to recover from the failure.), (Recommended Action: Although the system will continue to run, the backup image set might be of older version and it might have known issues that have been fixed on latest version. So it is critical to address the problem as soon as possible. The output of 'show hw-module location fpd' will identify the image with the problem with NEED UPGD state and it will have missing Programmed version. To correct the problem, use the 'upgrade hw-module location fpd ' command to re-program the FPD image and power-cycle the affected card for FPGA to load with the upgraded image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP maximum-prefix feature? ### Response: The maximum prefix feature allows a maximum number of prefixes to be configured for a BGP session. If the number is exceeded, the session can either be torn down or a warning can be logged. This protects against misconfiguration or DoS attacks. It is configured with the neighbor maximum-prefix command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ITAL-2-INIT_FAILURE ### Response: (Severity: 2), (Category: OS), (Description: ITAL Initialization failed. The message displays the failed operation and the error code. ITAL connects with various servers to get required information for process from which it is invoked. It might lead to unstable state of the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-3-ERR_INTF_STATS ### Response: (Severity: 3), (Category: L2), (Description: It was not possible to register for stats collection on the specified interface. The entry in the 'show interface accounting' command is likely to be inaccurate for CDP packets.), (Recommended Action: Try restarting CDP and the Statistics server process on this node. proc restart cdp location proc restart statsd_server location If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-CONFIG_UNKNOWN_KEYWORD ### Response: (Severity: 3), (Category: OS), (Description: Syntax error in PIFIB flow handling configuration. The named flow type may have default characteristics applied.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_9_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_9 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-WARM_RLD_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: Card seems to have been cold reloaded after an attempt to warm reload the card.), (Recommended Action: Capture the shelfmgr log and use the 'show shelfmgr trace' CLI in admin-mode to fetch debug information. Also capture sysmgr_nv.log from LC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-ENABLE_PORT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath failed to enable ports. This error could occur for two reasons. 1. The system is low on resources. 2. A hardware error or an error in the DPAA software.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect show log location output, show controllers dpaa trace all location output and show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-TX_ALARM_OC ### Response: (Severity: 3), (Category: PLATFORM), (Description: BITS transmitter has detected an open circuit condition.), (Recommended Action: Ensure cable connection between the configured interface port and external equipment.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_RIB-5-BATCH_ERROR ### Response: (Severity: 5), (Category: ROUTING), (Description: The specified error was encountered in the OSPF RIB batching code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does IOS XR manage configuration during package activation and deactivation? ### Response: During package activation in IOS XR, any new configuration options introduced by the package become available. During package deactivation, the configuration related to the package is automatically removed to ensure consistency. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FILECOPY-4-SYSDBUNBIND ### Response: (Severity: 4), (Category: OS), (Description: The filecopy_process was unable to unbind from sysdb when shutting down. This may result in a failure to re-register with sysdb when the process is restarted later. Collect show tech-support sysdb on the location where this error is seen.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-STATS_SYNC_DISABLE_FAIL ### Response: (Severity: 4), (Category: INFRA), (Description: An error was encountered when attempting to remoce statistics synchronization configuration for the named interface. This is likely to result in the Exposed XR Interface in Linux continuing to report the same statistics values as were synchonrized from IOS-XR before the error was seen.), (Recommended Action: Try re-adding and then removing statistics-sychronization configuration for the affected interface. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EEM-3-ACTION_SYSLOG_LOG_ERR ### Response: (Severity: 3), (Category: HA), (Description: The action_syslog call from tcl script.), (Recommended Action: Please verify command(s) mentioned in tcl script prior to error message are working fine (on router prompt). If issue is still seen then please provide command details which has resulted into this error condition to technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-FSMTIMEOUTA_RESET ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is not able to boot up. This is because the timer A has expired on this node before any boot request was recieved by shelfmgr from this node, after the node has reached the ROMMON state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MOFRR_FLOW-3-DETECT_ACTIVE_BACKUP ### Response: (Severity: 3), (Category: ROUTING), (Description: LC control plane detected that traffic is already coming on backup path which is currently the selected path for forwarding traffic to egress LCs. Then set the HW watchdog of ingress NP to monitor traffic loss event on the path instead of monitoring traffic activity.), (Recommended Action: It is a self-recovery detection. There is no extra action needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-ACL_CONFIG_MIXED_MODE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: ACL being attached is of different mode than existing ones in the same NPU of the same lookup.), (Recommended Action: Remove all ACLs from interfaces of the same lookup type in the same NPU or stay with the current prevailing ACL mode.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR_ASIC-3-FMEA_INTR_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: 'FMEA interrupt based fault found'), (Recommended Action: Reboot the device.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_EDM-3-DATALIST_CREATE_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The creation of the external data manager datalist has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MARVEL-3-DEBUG_INIT ### Response: (Severity: 3), (Category: L2), (Description: Initialization of the debug event failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-1-UNSUPPORTED_CONFIG ### Response: (Severity: 1), (Category: DRIVER), (Description: Card manager has detected that the chassis contains unsupported configuration of cards. Operator has to take action and remove unsupported card from the chassis), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSHELL-3-WS_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: Initialization of functionality in getline library failed for reason mentioned in the error message. The whitespace completion behaviour could not be modified.), (Recommended Action: Exit the shell and get into the shell again. This would re-initialize the libshell library and error messages should no more appear. If the error message, persist; then undo the cli whitespace completion configuration from the line and call you're technical support representatives for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the interface preconfiguration feature in IOS XR? ### Response: The interface preconfiguration feature in IOS XR allows the configuration of an interface before the interface module or line card is inserted into the router. When the module is inserted, the pre-configured settings are automatically applied. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-WAIT_NULL0_INTF ### Response: (Severity: 6), (Category: ROUTING), (Description: NULL0 interface not up yet), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-3-ERR_SYSDB_SET ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_VCM-3-VC_NOTFOUND ### Response: (Severity: 3), (Category: L2), (Description: An operation was performed which expected a VC with the specified DLCI to exist, but it doesn't), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LNS_EA-4-ERR_RWMGR ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: LNS EA encountered an error communicating with Rewrite Manager. The error message describes what operation has failed and why it failed. The most likely reason for this is a temporary connection problem with the Rewrite Manager Server process, but the error could also be caused by low memory resource or programming error.), (Recommended Action: In many cases, LNS EA will recover by itself. If it does not then restarting the process may help. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-IM_INVALID_BOARD_ID ### Response: (Severity: 3), (Category: PLATFORM), (Description: Invalid Board ID read from IM.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TURBOBOOT-4-ROMMON_VARIABLE_NOT_SET ### Response: (Severity: 4), (Category: INSTALL), (Description: 'The TURBOBOOT rommon variable was not set to 'on'. The system has ' 'membooted. Set the TURBOBOOT variable to 'on' to prepare the system for' 'diskboot.'), (Recommended Action: 'Membooted system is not advisable. Diskboot the system by reloading the' 'system with the TURBOBOOT rommon variable set to 'on'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKEND-7-INTERNAL_PATH ### Response: (Severity: 7), (Category: SYSDB), (Description: The backend library has either failed a function that expected to succeed, or has got into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-ID_CERT_EXPIRED ### Response: (Severity: 3), (Category: LICENSE), (Description: The device has not communicated with Cisco for an extended period of time and the device has not automatically renewed the device registration with Cisco.), (Recommended Action: Please check the Smart Call Home settings and network connectivity to cisco.com.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_SPURIOUS_INTERRUPT ### Response: (Severity: 3), (Category: FABRIC), (Description: An interrupt is generated but the interrupt status register indicates no pending interrupts. This may be due to a hardware error where the interrupt line is stuck in its active state i.e. active low.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-LICENSE_EXPIRED ### Response: (Severity: 4), (Category: LICENSE), (Description: The specified feature's evaluation license has expired. The feature will no longer be usable. The message appears even if the feature is not currently configured.), (Recommended Action: In order to continue using the feature, obtain a license and install it using the 'license add' command in admin mode.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEM-3-STATS_CALLOC_FAILED ### Response: (Severity: 3), (Category: L2), (Description: Due to memory allocation failure for stats array, g_spa process needs to be restarted.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - Restart the g_spa process. - Check for memory conditions in the system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_PRM-6-COMPLETED_WAIT_FOR_NP_UP ### Response: (Severity: 6), (Category: PLATFORM), (Description: New NPs are up now. Waiting is complete.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGV6_SERVICES-3-MSG_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in the cgv6 services process during process initialization or process communication.), (Recommended Action: collect the info from 'show diag', 'show platform', 'show inv', 'show logging') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C_SERVER-3-ACT2_AUTH_STATUS ### Response: (Severity: 3), (Category: PLATFORM), (Description: ACT2 Authentication status for RP.), (Recommended Action: - PASS : No action required. - SKIP : Reason for skipping is mentioned in the message. Contact TAC, if there is discrepancy in the reason. - FAIL : Card will reload. Immediate action required. Contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: METRO_STATS-7-ERR_EXHAUST ### Response: (Severity: 7), (Category: L2), (Description: This is a debug message in the Hardware Stats Manager to indicate the stats counters of the particular stat type is exhausted. In most cases these messages will stop once the temporary condition is resolved. Examples of when this error occurs are: 1. The client tries more counters than that are free for that type), (Recommended Action: No action is required. These are Debug messages. An error was returned by Stats Manager to applications. Applications receiving this error will report the error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FM-4-EVENT_CONN_NOTIFY ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: An internal error was detected when trying to set notify handler for connection opens, closes and errors.), (Recommended Action: In this case the process may not be UP yet. There is a retry mechanism to handle this issue. If the issue continues, restarting netio and lpts_fm may fix.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDEVINFO-3-SIGNAL_RELATED ### Response: (Severity: 3), (Category: MEDIA), (Description: Some signal related function returned with an error.), (Recommended Action: restart process 'fs_dev_info' from exec prompt - from exec prompt 'restart process fs_dev_info' if issue persists contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_OUT_MEM_CORR_ECC_ERROR_LNK4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast output memory correctable ECC error on link 4), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: eth_gl-4-INIT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The indicated process failed to initialize. Previous messages may give the reason. The process will automatically restart and retry. Until it succeeds, Ethernet functionality may be impacted.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BMP-3-DLL_INIT ### Response: (Severity: 3), (Category: L2), (Description: A failure occurred during the initialization of the platform dependent adjacency programming DLL. This will result in the hosting process being restarted.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-RIB ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred on a request to the RIB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospfv3 - show ospfv3 trace all - show ospfv3 routes - show route ipv6 detail - show rib ipv6 clients. Find the client ID of the bcdl process that is in the insync state to plug into the next command. - show rib ipv6 client-id redist history) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-SYSDB_DATALIST_CREATE ### Response: (Severity: 4), (Category: OS), (Description: An internal sysdb function failed. When this issue happens, it will trigger an automatic restart of pifibm_server_lc process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_PERF_DATA_POOL_EXHAUSTED ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_THOR_L2FIB_DEBUG-3-REGISTER_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-SCHED_SETSCHEDULER ### Response: (Severity: 7), (Category: HA), (Description: The sched_setscheduler() function returned an error which is indicated in the message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CETHHA-2-PORT_FAULT ### Response: (Severity: 2), (Category: PLATFORM), (Description: The rate of link errors on the control ethernet port has exceeded the threshold. The link should be fixed to avoid disruption in router services.), (Recommended Action: Fix the bad link after switching traffic to redundant link.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XFP-3-HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected an XFP temperature greater than or equal to the high temperature warning threshold. The XFP is the pluggable optics on the line cards. The temperature threshold values are read from the XFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational, and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the command to display OSPF neighbor information in Cisco IOS XR? ### Response: To display OSPF neighbor information in Cisco IOS XR, use the command 'show ospf neighbor'. This will display a list of OSPF neighbors, their state (FULL, 2-WAY, INIT, etc.), the interface they are reachable through, and the length of time they have been in their current state. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-3-DPC_FAIL ### Response: (Severity: 3), (Category: L2), (Description: An error occurred during the Data Path Control send operation. The DPC message sent here is to update state change/db in EA.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: deflate-3-process_file_error ### Response: (Severity: 3), (Category: OS), (Description: Deflate cannot process the file for uncompression due to the reason given in the error message), (Recommended Action: Please check the input file to be valid if the error is due to user entered CLI. Please capture show log and error messages if the error is not due to user entered CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_COM_NETIO-7-DEBUG_CLEANUP ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when cleaning up debug.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-EA_SHM_INIT_FAILURE ### Response: (Severity: 3), (Category: QOS), (Description: QoS_EA failed to initialize stats shared memory(after retry count = 5). QoS drops will not be reported for any qos enabled interfaces in the output of show interface CLI.), (Recommended Action: Take a look at the system memory and the processes which are running. Restart QoS_EA process when the memory usage goes down.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HYPHY_FRAMER-3-HYPHY_ASIC_ERROR ### Response: (Severity: 3), (Category: OS), (Description: An unexpected error occurred.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-5-SATELLITE_REDUNDANCY ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-TMA_CLUSTER_PARITY ### Response: (Severity: 0), (Category: PLATFORM), (Description: A parity error interrupt), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD_inv-6-NON_DRP_PRIMARY ### Response: (Severity: 6), (Category: HA), (Description: This is an informational message output during SDR configuration commit time only if a non-RP or non-DRP node is being assigned as primary to the SDR. Please note that if the node is not in IOX-RUN state, it's node type will not be determined.), (Recommended Action: Verify the card type in the slot being configured as primary for the SDR. If not a DRP or RP card, please replace with valid card type.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBUS-7-SVC_INVALID_STREAM ### Response: (Severity: 7), (Category: PLATFORM), (Description: mbus debug information %d - is the stream identifier.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFLX_LIB_MGR-6-NOT_ENOUGH_MAC_ADDRESSES_RESYNC ### Response: (Severity: 6), (Category: SERVICES), (Description: The Interflex Manager was unable to obtain enough MAC addresses for the configured Interflex interfaces. The system has a finite number of MAC addresses in the hardware, which are all currently used.), (Recommended Action: A MAC address should be manually assigned to any Interflex interfaces which were unable to obtain one from the hardware.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-4-INTERFACE_PORTS ### Response: (Severity: 4), (Category: MGBL), (Description: The total number of ports could not be determined for this interface. Configuration manager will not be able to determine if there is any more configuration for remaining ports.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-6-EOBC_LINK_DOWN ### Response: (Severity: 6), (Category: PLATFORM), (Description: A link on epm switch device is down), (Recommended Action: '*show controllers epm-switch port-mapping location *') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_ATM_V2-3-SHEM_ERROR ### Response: (Severity: 3), (Category: L2), (Description: SPA process encountered an internal software error. SPA is in not ready state . Shared memory is initialized with in inconsistent state.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2VPN-3-RSI_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to extract nodeid to rsi value.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_EA-3-FORWARDER_CONNECTION ### Response: (Severity: 3), (Category: SERVICES), (Description: The forwarder driver has restarted, but this process was unable to handle this as the error was unexpected. It is possible, though not necessarily true, that slow path packet processing for some interfaces owned by this process may be broken.), (Recommended Action: Restarting the relevant SVI Manager process will prompt a resync, which should get the SVI Manager process and forwarder driver back into step. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-FANTRAY_VER_MISMATCH ### Response: (Severity: 4), (Category: PLATFORM), (Description: Fantray version is different from the existing one. This is not a critical condition.), (Recommended Action: Verify the fantary version, give CLI: (admin)# show diag --> particularly fantray output Use same fantray version based on the requirement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-BF_SBE_ERR_FIA00 ### Response: (Severity: 3), (Category: PLATFORM), (Description: FIA00 burst FIFO single bit error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_HIGH_VOLT ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when one of the voltage sensors on satellite has crossed higher threshold.), (Recommended Action: No recommendation) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-SYSDB_BIND_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XCVR-6-ENABLE ### Response: (Severity: 6), (Category: PLATFORM), (Description: Add device to list of devices on spa plugin which refers to the xcvr which is added is enabled and ready %s - xcvr type), (Recommended Action: This is just an informational message No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XRV9K_FIB-6-EVENT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The messages indicates a specific event or milestone has occured.), (Recommended Action: No action needed. This is an information message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-6-PRINT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Printing the data for test purpose from the database.), (Recommended Action: This is informational print only, no action to be taken.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX8508-2-BIST_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: There was a failure in built-in self-test of PCIE device), (Recommended Action: Please reload the board using the following command: 'reload location <>' If the issue persists please, contact your technical support representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: tunnel_ea-3-UIDB_INIT_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This is typically an internal error in the software. The software failed to initialize a connection to another process in the card where the error is seen.), (Recommended Action: If there is a problem, it might be cleared by restarting tunnel_ea. If the problem persists, copy the error message as it appears on the console and any noticeable side effects. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-4-ISSU_NOTIFICATION_FAILURE ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred when sending a notification for ISSU. If the ISSU operation succeeds, then this warning can be ignored; if not, then this warning may give an indication of why the ISSU operation failed.), (Recommended Action: Follow the recommended action specified by the ISSU processes.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSC-7-ERR_DEBUG_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric statistics client library encountered debug facility registration failure. When this error happens, the library will not able to enable debug.), (Recommended Action: Restart Fabric statistics client manually if the error is persistent.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-EVC_INITFAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of the CGN process on a particular node. The errors were seen during event connection operation. The process will be restarted. The issue is during event conneciton operation. This will impact the functionality of CGN.), (Recommended Action: Try restarting the CGN process showing this error. Please contact support if the issue does not get resolved after process restart.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_AUTO_TUN_BKP_TUN_LIMIT_EXCEEDED ### Response: (Severity: 3), (Category: ROUTING), (Description: The creation of the auto-tunnel backup aborted since it would have exhausted the tunnel interface scale limit), (Recommended Action: Reduce configured/auto tunnels to below the system scale limit) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_UTIL-7-COLD_RESTART ### Response: (Severity: 7), (Category: HA), (Description: Due to too many contiguous failed restarts, sysmgr has requested that the process be restarted without CDM data.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-MEMORY_RECOVERY_KILL_PROCESSMGR ### Response: (Severity: 6), (Category: HA), (Description: The process has been killed in an attempt to recover system memory. The process can be manually restarted if desired, but may continue to consume large amounts of memory.), (Recommended Action: The system is critically short of memory. Automatic recovery will attempt to stabilize the system, but there is either a memory leak or a misconfiguration. Both require operator intervention.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE1_CODE_ERR_HIGH_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE1_CODE_ERR_HIGH interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-6-MAL_DATA_BUFF_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Info about media access lib, used to communicate with linux ethernet device driver. %x- Payload bytes 25,26,27 and offset.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-6-SIGNAL_RCV ### Response: (Severity: 6), (Category: INFRA), (Description: ESD has received a signal. This may be user initiated or could indicate an error. ESD may exit as a result.), (Recommended Action: Check the signal type. If not user initiated, then root cause of the signal needs to be determined.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-FAILED_RELOAD_NODE ### Response: (Severity: 2), (Category: INSTALL), (Description: The installation required a reload of the dSC node, but the reload failed. The software installed will now be in an inconsistent state.), (Recommended Action: Execute the command 'hw-module location reload' for the specified node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPM-3-ERROR_ENTRY_FIND ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to find an entry for the file to be deleted.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-MULTICAST_IGP_MTR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-NODE_XR_HB_TIMEOUT_RESET ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the card is being reset because of a failure to get XR heartbeat from a specific node. This is an indication of an error condition during MBI RUNNING state.), (Recommended Action: If the problem persist, collect the reset debugs collected under the harddisk:/shelfmgr_debug directory (debug files collected for each node will be created under its own subdirectory), log files under the harddisk:/bcm-logger/ (under last couple of sub-directory) and the output of 'show tech-support install', 'show tech-support shelfmgr' and 'show tech-support control-ethernet' commands before contacting Cisco for technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-3-STALE_TLV ### Response: (Severity: 3), (Category: L2), (Description: CDP received a notification to update a TLV that it sends but failed to do so due to the error given. The information stored by CDP is now out of date.), (Recommended Action: Perform 'cdp disable', 'cdp enable' on the interface. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSH_IPC_EM-3-EVM_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: OSH IPC ethernet media event manager initialization failed.), (Recommended Action: restart the process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_LMRIB_TUNNEL_RW ### Response: (Severity: 3), (Category: ROUTING), (Description: A LMRIB Tunnel Rewrite related error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Collect: -show logging -show tech-support mpls traffic-eng -show lmrib client trace for further analysis of the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCRIPT_MGMT-5-NOTIFICATION ### Response: (Severity: 5), (Category: OS), (Description: Normal but significant conditions.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_EA-3-MALLOC ### Response: (Severity: 3), (Category: L2), (Description: Memory allocation failure detected. The node might have run out of memory.), (Recommended Action: Should check memory conditions on the system) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CMPP-4-ERR_LTRACE ### Response: (Severity: 4), (Category: INFRA), (Description: CMPP encountered an error using the Lightweight Tracing service. The error message describes what operation has failed and why it failed. This is a fatal error and the CMPP process cannot continue. It will abort and subsequently be restarted by SysMgr in an attempt to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-3-APIV_REGIST_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: API Version registration failed.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-3-topology_inconsistencies ### Response: (Severity: 3), (Category: OS), (Description: The topology database is in an inconsistent state after BGP-LS updates.), (Recommended Action: Enable 'debug segment-routing traffic-eng error' for detailed information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different IPC mechanisms available in Cisco IOS XR? ### Response: Cisco IOS XR supports several IPC mechanisms suited for different use cases\n- Lightweight messaging (LWM): Synchronous, connection-oriented, intra/inter-node\n- Group services protocol (GSP): Asynchronous, connectionless, multicast-based\n- Bulk content downloader (BCDL): Uses GSP to efficiently download large data sets\n- Qnet protocol: Extends message-based IPC transparently across nodes\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKWATCH-6-USER_INFO2 ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The info about the total number of users of the specified resource.), (Recommended Action: It is an informational message along with packet depletion log message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-3-SLOT_INSERTION_THRESHOLD_MAJOR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Backplane slot connector has card insertions exceed threshold major per current counter statistics.), (Recommended Action: Give CLI: (admin)# show plugin slot counts location Service the backplane slot connector, contact Cisco TAC for assistance. If possible, reduce the frequency of card insertions into this backplane connector. Current insertion counters may be cleared with (admin)# clear plugin slot location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-5-ASIC_ERROR_SCRUB_THRESH ### Response: (Severity: 5), (Category: PLATFORM), (Description: ASIC errors have occured and need memory scrubbing, such errors have crossed threshold.), (Recommended Action: Errors have been handled. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_EVM_CONN_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-3-PIFIBM_INIT ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to initialize the Pre-IFIB Mgr.), (Recommended Action: Please share the output of the following commands: - show tech-support lpts - show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure LDP targeted session? ### Response: To configure an LDP targeted session, use the 'targeted' command under the MPLS LDP neighbor configuration. RP/0/RSP0/CPU0:router(config)#mpls ldp RP/0/RSP0/CPU0:router(config-ldp)#neighbor 192.168.1.2 targeted <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE3_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE3_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MIRROR-3-ERR_GENERAL ### Response: (Severity: 3), (Category: MGBL), (Description: 'mirror encountered error, see message for more details'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LWMESS-7-CORRUPT_CLI_SKIP ### Response: (Severity: 7), (Category: OS), (Description: A corrupt memory area was discovered in an internal data structure. A function that was searching the open connection list was not able to process all open connections.), (Recommended Action: This is an internal error and should be reported to TAC. Take a memory dump and try re-starting the offending application.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-SYSMGR_PR_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: CGN_MA failed to send process ready notification to sysmgr, the process will restart under this scenario.), (Recommended Action: Try restarting the CGN process showing this error. Please contact support if the issue does not get resolved after process restart.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-UNLINK_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Could not delete a file. This might impact dumper.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-DCDC_SEND_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that Shelf Manager has failed to send a dcdc_enable request to the remote board.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_SYSDB_GET ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-FSMTIMEOUTB_RESET ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is not able to boot up. This is because no mbi-hello heartbeat has been recieved by shelfmgr within the time specified by timer B.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_0_LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature less than or equal to the low temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CPAK with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-BOARD_NOT_SUPPORTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is being shutdown because it is not supported on the CRS-4 platform.), (Recommended Action: Remove the unsupported board and replace it with supported hardware.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-COND_WAIT ### Response: (Severity: 3), (Category: OS), (Description: Error signaling cond variable.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_FPD-3-CPA_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that a failure has occured in CPA interface.), (Recommended Action: action mentioned in the message should be taken.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTIO-4-PULSE_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The VTIO SPP plug-in failed when attempting to communicate between threads.), (Recommended Action: If any problems are seen, they may be rectified by restarting the spp process using the 'process restart spp' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM-3-MHOST_DEFAULT_PIM ### Response: (Severity: 3), (Category: IP), (Description: When multicast routing is turned on PIM will choose a default interface, based on whether the default has been configured and it's enabled state. An error was encountered in making PIM provided interface as mhost default interface.), (Recommended Action: Change the mhost ipv4 default-interface configuration to some other physical or virtual interface. Collect the output of show tech-support, show arm ipv4 trace) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NAL-4-SUBSCRIBERS_DELETE ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This syslog is printed when the parent interface configuration is modified or parent interface is deleted and subscribers are present on that interface.), (Recommended Action: This is warning to alert the user that sessions present on parent interface will be deleted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_REG_SHUTDOWN_NOTIFY ### Response: (Severity: 4), (Category: ROUTING), (Description: A call to system manager to register for shutdown notification failed. This is a recoverable error in that shutdown actions are not critical.), (Recommended Action: No action is required..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-SERVICE_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: NPU driver was not able to connect to the service with the above error condition.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_10_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_10 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-4-INTR_ENABLE_FAIL ### Response: (Severity: 4), (Category: FABRIC), (Description: Hardware state is not correct.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_MAIN-4-CLOCK_ALERT ### Response: (Severity: 4), (Category: PLATFORM), (Description: One of the internal/external clock interfaces have reported an alarm as specified in the alarm description. This does not necessarily mean any fault in the hardware. Some alarms can occur transiently during clock-events like configuration changes, network events or cabling changes. The alarms should cancel within few minutes in such cases. If the alarms persist then it may not affect routing/forwarding but timing distribution may be impacted.), (Recommended Action: Ensure cable connection between the configured interface port and external equipments is proper.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_SB_SERDES_0_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data south bound serdes link 0 failure on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-4-VNI_UNSUPPORTED_MODE_CHANGE ### Response: (Severity: 4), (Category: L2), (Description: VNI updates from NVE module shall never transition directly from Layer 2 Control Plane to Layer 3 Control Plane directly, or vice-versa. It is expected that NVE will delete the Access Circuit VNI first and re-create it using the other mode.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-CRC_ERR_0_NPU_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: CRC error from NPU-0 on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_TRAFFIC_ALERT_NETFLOW-1-NOT_UP ### Response: (Severity: 1), (Category: SERVICES), (Description: The afmon_ea process encountered the specified error while trying to update flow record when nfsvr was down.), (Recommended Action: Please check if nfsvr is up Please collect 'show tech-support performance-traffic' and contact Cisco technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to define the configuration register boot value in Cisco IOS XR? ### Response: To define the configuration register boot value, which determines how the router functions during initialization, use the 'config-register' command in administration EXEC mode. RP/0/RSP0/CPU0:router#admin RP/0/RSP0/CPU0:router(admin)#config-register 0x2 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-4-RING_LOOKUP ### Response: (Severity: 4), (Category: OS), (Description: When RDS library tried to search for an identifier in the atomic tag ring, it returned failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPENET-3-RESET_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cannot reset the card as reset bit didn't clear.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KIM-1-LOG_ALERT ### Response: (Severity: 1), (Category: INFRA), (Description: please see show kim log for more information.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-THREAD_CNT_SEVERE ### Response: (Severity: 3), (Category: HA), (Description: When number of threads has crossed above SEVERE Threshold Percentage.), (Recommended Action: The number of Threads running has increased. Determine if there are any unnecessary threads available in dir '/var/log/debug_proc_cnt' and kill them by using kill -9 .) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SESSION_MON-3-GEN_ERROR ### Response: (Severity: 3), (Category: SNMP), (Description: Generic error message used for internal debugging.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_INFRA-3-inform_failed ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to inform config manager), (Recommended Action: Please contact tech support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR-6-ERROR_LOG_SUCCESS ### Response: (Severity: 6), (Category: PLATFORM), (Description: Sucessfully logged error into Asic Error library and PCDS library. Client ID and error key are shown.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABMGR-1-SPINE_UNAVAILABLE ### Response: (Severity: 1), (Category: PLATFORM), (Description: Number of active spine cards is less than required. This could result in reduced fabric bandwidth.), (Recommended Action: Make sure all spine cards are seated properly and recommended number of spines are powered up. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-LTRACE_INIT ### Response: (Severity: 3), (Category: OS), (Description: An internal ltrace_init2 function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_CLIENT-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an information log.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_BCDL_CONSUMER-3-ERR_EVM ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID BCDL consumer encountered the annunciated Event Manager Error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-6-LICENSE_CLEAR_POOL ### Response: (Severity: 6), (Category: LICENSE), (Description: As a result of 'clear license' command execution, license pools other than the Owner pool were cleared.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: adminexec-4-DISPLAYING_DEFAULT_HOSTNAME ### Response: (Severity: 4), (Category: MGBL), (Description: Unable to bind to sysdb to get hostname hence displaying default hostname.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-NPU_1_FC_DIP2_ERR_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress flow control DIP2 parity error on NPU-1 interface on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-ISSU_MARKED_NODE_NC ### Response: (Severity: 4), (Category: INSTALL), (Description: As part of ISSU operation, the specified node did not comply to ISSU infrastructure as it got reloaded. Thus it will be held in MBI until the current ISSU operation is completed and then will be will be booted with the new version of the software.), (Recommended Action: The node will be booted with the new version once the current ISSU operation is complete.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-GET_MY_NODEID_FAIL ### Response: (Severity: 3), (Category: IP), (Description: This failure can happen in show commands as well as in main CE-TFTP server process.The process will exit and respwan itself.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-3-UNSUPPORTED_CARD ### Response: (Severity: 3), (Category: PLATFORM), (Description: Unsupported card is found. Only Cisco approved card can be used), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Check the card in slot is a Cisco approved card. Replace the card if not. If the card is on the Cisco approved, please submit a ddts together with 'show filesystem ' information together with the product information on card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_5_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_BADFORMAT ### Response: (Severity: 4), (Category: SYSDB), (Description: An unescaped ''' character was found part way through a token in a command string.), (Recommended Action: Re-enter the command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2RIB-3-ERR_REMOTE_TO_STATIC ### Response: (Severity: 3), (Category: L2), (Description: Remote host cannot be assigned a MAC address which is configured as a static MAC address. Statically configured MAC address takes precedence. All traffic destined to MAC address will be forwarded using static MAC configuration.), (Recommended Action: Please assign different MAC address to remote host or change statically configured MAC address.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDS_DB-3-CHAN_CONNECT ### Response: (Severity: 3), (Category: OS), (Description: Failed to connect with the message channel.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-3-DSDRSC_UNAVAILABLE_FOR_SW_DWNLD ### Response: (Severity: 3), (Category: INSTALL), (Description: The node requires software that is only available on the dSDRSC. It cannot continue booting until the dSDRSC becomes available. If this node is supposed to become the dSDRSC then it is missing software that it requires to operate.), (Recommended Action: Wait for the dSDRSC to become available. If this node is supposed to become the dSDRSC then it is missing software that it requires to operate in which case the node should be moved into the Owner SDR and then recarved into a separate SDR.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSLA_TS_SVR-3-EVENT ### Response: (Severity: 3), (Category: MGBL), (Description: An error occurred while processing an event at the time stamp server event manager), (Recommended Action: This is an unusual situation which should not occur under normal circumstances. If the situation persists it may require the restart of the time stamping process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the admin plane in IOS XR configuration? ### Response: The admin plane in IOS XR is used to configure system-wide resources such as disk partitions, control Ethernet interfaces, and user access. It is not used to configure routing protocols or interfaces that carry user traffic. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_HFR-7-ERR_SEND_INGRESS_PKT ### Response: (Severity: 7), (Category: PLATFORM), (Description: Cannot send packet to qad queue, likely the qad queue is full and application does not drain the qad queue fast enough %s - error description %d - 0 ingressq; 1 egressq; 2 fabricq 0; 3 fabricq 1 %d - queue number %x - error code), (Recommended Action: Ignore the message if it only appears once otherwise contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_PRM-3-MUTEX_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Mutual exclusive lock or unlock error happened to the queue.), (Recommended Action: Please collect output of the following commands: show platform show platform vm show log show process blocked location <> show process fib_mgr location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2RIB-3-ERR_STATIC_TO_LOCAL ### Response: (Severity: 3), (Category: L2), (Description: Local host cannot be assigned a MAC address which is configured as a static MAC address. Statically configured MAC address takes precedence. All traffic destined to MAC address will be forwarded using static MAC configuration.), (Recommended Action: Please assign different MAC address to local host or change statically configured MAC address.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_MA-7-INVALID_CAPS_STATUS ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-SHUTDOWN_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: locald process failed to shutdown properly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOADPATH-7-PACKAGE_OUTPUT_SORT ### Response: (Severity: 7), (Category: INSTALL), (Description: The sorting algorithm used for sorting packages that are to be output using a 'show install active' type command, failed to perform correctly. Although the packages will be output, they may not be in the standard order.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-2-PARSE_CLUSTER_PARITY ### Response: (Severity: 2), (Category: PLATFORM), (Description: A parity error interrupt), (Recommended Action: This error can be corrected by reloading the LC using the command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-TX_SECURE_CHANNEL_ESTABLISHED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDBUTILS-7-INTERNAL_NODEID_STR ### Response: (Severity: 7), (Category: SYSDB), (Description: The client library was unable to convert the specified node ID into a node description string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-WARM_BOOT_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: System could not sync with ASIC during warm boot. ASIC shall be reset and traffic forwarding would be impacted.), (Recommended Action: No further recovery is needed at this point. System shall auto-recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-3-BUNDLE_SPAN_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The error indicates that monitor-session data update in HW for Bundle or its member failed.), (Recommended Action: Please verify the Bundle and monitor-session configuration. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-STATS_DB_ERROR ### Response: (Severity: 4), (Category: L2), (Description: An error was encountered with the PTP statistics database, packet counters may be invalid.), (Recommended Action: No action is required. If the message continues to be seen, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFI_EA-3-STATE ### Response: (Severity: 3), (Category: L2), (Description: The SFI EA process failed to update the state of a SFI interface.), (Recommended Action: Collect debugging information, shut/no-shut tunnel interface. If the above action doesn't fix the problem, remove tunnel interface, re-create tunnel interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-6-UPGRADE_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message related to the Canbus Controller upgrade process on the specified location.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_RC_HEX ### Response: (Severity: 3), (Category: SECURITY), (Description: Error description, hex_code of rc.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-2-ERR_RC ### Response: (Severity: 2), (Category: PLATFORM), (Description: Error in CPU Control FPGA operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-TSP_A_PKT_CRC_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: TSP decoder A CRC error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-6-INFO_REKEY ### Response: (Severity: 6), (Category: SECURITY), (Description: The sshd rekey information.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-BADVERS ### Response: (Severity: 4), (Category: ROUTING), (Description: The system received an OSPFv3 packet with an OSPF version field other than 3. This indicates an error in the sender of the packet.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LACP_LITE-3-ERR_LL_DLL_CHAN_CONNECT_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Attempt to connect to LACP lite process channel fails), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-SLR_FAILED ### Response: (Severity: 4), (Category: L2), (Description: An error occurred while processing a received SLM message, resulting in a failure to send a SLR reply. - the error string gives more details. This is a problem because the SLR is needed in order for the sender to correctly calculate packet loss measurements. This error is not caused by malformed or invalid packets. The SLM test session will now be invalid.), (Recommended Action: If the error reason given at the end of the message indicates that too many SLMs have been received, then no more new SLM sessions can be supported. The number of SLM session is platform dependent and is the minimum of the Maximum SLA operations and entry shown in show ethernet cfm platform-capabilities. If the command is not present, contact TAC for confirmation of the details. This message will be seen if more than that number of operations are being attempted (for the specified linecard). This message may also be seen if there are inactive SLM sessions still stored in the database, taking the total entries above the limit. Any inactive session entries will be cleared by the database within 5 minutes. To resolve the issue urgently, the database may also be cleared by restarting the cfmd process on the node where the error is occurring. This action will result in all existing test sessions reporting a small number of lost packets. Otherwise, the error reason will either indicate memory exaustion on the LC, or some other unexpected condition. If this error occurred as a result of memory exhaustion; attempt to resolve any memory issues before attempting to solve this problem. As we have failed to respond to an SLM, it may be useful to restart the test from the source device once the issue is resolved.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-0-CPU_ERR0 ### Response: (Severity: 0), (Category: PLATFORM), (Description: Indicates Hardware correctable error (no operating system or firmware action necessary). This error message is thrown after observing hardware correctable error.), (Recommended Action: Reload the LC that has the problem. If problem persists, contact support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XBAR-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: PLATFORM), (Description: Crossbar driver encountered a fatal memory allocation error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: NPUXBAR bridge has a minor error.), (Recommended Action: Minor error, no action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPv4-4-TRANS_WARNING ### Response: (Severity: 4), (Category: IP), (Description: There was a critical system call failure. System may not have handled certain transitions properly.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the three configuration planes in IOS XR? ### Response: The three configuration planes in IOS XR are: admin plane, shared plane, and local plane. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEMPOOL_EDM-3-MALLOC_FAILED ### Response: (Severity: 3), (Category: OS), (Description: Memory running low), (Recommended Action: This indicates low-memory condition. 'Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.' 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-5-HA_NOTICE ### Response: (Severity: 5), (Category: ROUTING), (Description: Used for logging of HA events like process startup, entry and exit of NSF/GR or NSR procedures and related events.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-7-CHKPT_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to perform checkpoint service functions.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-3-INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: A software error occurred while starting up of ANCP process. The exact reason for the error is as specified in the message. The condition could most probably happen because of the following: 1) Unavailabilty of a particular resource at the time of intilization 2) Race condition 3) Memory initilization error/ shortage), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and if ANCP process is able to initialize and come up successfully after restart, then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rspp_drop-3-UNDIVERT ### Response: (Severity: 3), (Category: SERVICES), (Description: A packet could not be sent out to its original destination after firewalling. The packet was dropped.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_AGORA_ALM_TYPE_FOUR ### Response: (Severity: 2), (Category: PLATFORM), (Description: AGORA type four alarm.), (Recommended Action: If the problem persists, call your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_TOPAZ-7-ERR_EVENT_CONN_NOTIFY ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to register event handler for disconnection or connection error event. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM_PD-4-ERR_ADJ_DLL_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the platform independent adjacency completion DLL. This will result in the hosting process being restarted.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG_PLAT-3-COULDNOT_REGISTER_NOTIFY_SHELFMGR ### Response: (Severity: 3), (Category: INSTALL), (Description: Retry registration fixed number of times. Notifies shelfmanager when it unable to register.), (Recommended Action: Please contact TAC after trying maximum retries.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAK_CAPTURE-4-ECC_ERROR ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: A packet was dropped in hardware due to bad programming or a hardware error. This is a raw dump of the packet to aid in debugging.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-TDB_REGISTER_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A static routing process failed to register a table with RIB. This may lead to routes associcated with a the failed to be added in the routing table.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route static').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_CONF_PRX-3-ERR_GENERAL ### Response: (Severity: 3), (Category: SECURITY), (Description: SSH encounterd some error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-ERR_DELETE_SGSERVER ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCASTSN-5-BELOW_THRESHOLD_VALUE ### Response: (Severity: 5), (Category: L2), (Description: Number of groups have gone below the group threshold mark. Safe to add more groups.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-AUTH_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The license authorization is expired.), (Recommended Action: The customer should check the connection to the backend Smart Licensing server.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ED_SCH_INTR_MC_BUFFER_HANG_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ED_SCH_INTR_MC_BUFFER_HANG interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-6-RACK_UP_NOTIFY ### Response: (Severity: 6), (Category: PLATFORM), (Description: Printing the node and rack details during RACK-UP event), (Recommended Action: This is an informational message. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUMI-7-SB_MBOOT_FAILURE ### Response: (Severity: 7), (Category: INFRA), (Description: Additional debug info for Secure Boot validation failure.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_12_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_3_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-3-NO_MEMORY_AVAILABLE ### Response: (Severity: 3), (Category: L2), (Description: An error was encountered while the memory was being allocated.), (Recommended Action: The process is automatically restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-7-UNEXPECTED_SEND_ERROR ### Response: (Severity: 7), (Category: SYSDB), (Description: The SysDB client library has failed to send a LWM message to the server, due to receiving an unexpected non-connection-related error in sending the message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTF_ERROR-3-MQ_OPENFAIL ### Response: (Severity: 3), (Category: TEST), (Description: Unable to open the message queue.), (Recommended Action: Restart the ctfmgr process using the CTF CLI commands, ctf kill manager, ctf expunge manager and ctf start manager.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-CDMA_RAM_UNCORRECTABLE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Indicates an uncorrectable multi-bit error occurred on this internal SRAM. %s - name of ram that error occurred %x - key of error node recorded %s - error data), (Recommended Action: if this happen continous, reload the board. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-6-SESSION_DAMPENING_OFF ### Response: (Severity: 6), (Category: L2), (Description: Session has moved out of dampening state either because of clear dampening or backoff timeout.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_BAD_PDU_VERSION ### Response: (Severity: 4), (Category: ROUTING), (Description: The PDU version reported in the IS-IS header is invalid (VERSION, should be EXPECTED) from SNPA (INTERFACE-NAME) This system received a protocol packet bearing an invalid VERSION in the header. The router originating the packet is either placing the wrong protocol version number in the packet, or else it is running an incompatible version of the IS-IS protocol.), (Recommended Action: Identify the source of the offending packet and correct it. If the message recurs 'debug isis packet-errors detail' may be used to provide a dump of the problematic PDU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-FSVFAIL ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: An automatic register for one of the FSVs failed.), (Recommended Action: If any of these messages occur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-CAT_ERROR_HANDLING_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process failed to handle ZENGL FPGA catastrophic/fatal event due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-1-_OOR_RED ### Response: (Severity: 1), (Category: PLATFORM), (Description: This is a severe error message in the OFA module to indicate high usage of OFA resources.), (Recommended Action: Please collect the OFA resource information (show controller npu resources all location all). Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-SRV6_LOC_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: The RIB returned an unexpected error when IS-IS attempted to (de)register for updates to the SRv6 locators. The problem may be caused by a low memory condition but is most likely to be an internal programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the IS-IS and/or the RIB processes. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-NETIO_SET_MAPPING ### Response: (Severity: 3), (Category: ROUTING), (Description: CLNS failed to setup mapping with this particular media or base capsulation. As a result CLNS will not be able to receive CLNS packets on this caps on any interface on this node.), (Recommended Action: Please contact cisco-support with the required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-7-ISM_PD_LIB_CE_CONN_INFO ### Response: (Severity: 7), (Category: INSTALL), (Description: Shows the invalid CE connections node informations), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-COMM_FAILED ### Response: (Severity: 3), (Category: LICENSE), (Description: The device communication with the Cisco licensing service failed.), (Recommended Action: Please check the Smart Call Home settings and network connectivity to cisco.com.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCASTSN-3-INIT ### Response: (Severity: 3), (Category: L2), (Description: An error occurred during initialization. These errors include timers, L2FIB or packet i/o.), (Recommended Action: Please check if the igmp snooping profile has been attached to the bridge domain by using the following commands. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp snooping profile command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp snooping profile output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp snooping bridge-domain detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp snooping bridge-domain detail output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp snooping port detail debug command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp snooping port detail debug output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-6-CLEANUP_NODE_PRESENT ### Response: (Severity: 6), (Category: PLATFORM), (Description: Prints the status of the flag value of the respective rack nodes during rack down event.), (Recommended Action: This is an informational message. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-3-SW_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The operation is failed due to an internal software error.), (Recommended Action: Check if the linecard reported any other errors. May need to restart process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-CLIENT_SHUTDOWN_START ### Response: (Severity: 4), (Category: PLATFORM), (Description: A request received from an IOS XR process to shut down the Network Processor), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRP_LIB-3-SW_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: Process encountered an error during software initialization. The process will automatically respawn up to a fixed number of times to try and recover.), (Recommended Action: Check if the linecard reported any other errors during the boot process as this error is normally associated with larger system issues. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-4-STBY_ACTIVE_NOT_READY ### Response: (Severity: 4), (Category: HA), (Description: RMF attempted to go active without the card ready - reset card), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-4-HEADLESS ### Response: (Severity: 4), (Category: PLATFORM), (Description: No active RP condition.), (Recommended Action: None, the LC will reload automatically if the condition persists.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-5-CLEAN_ALL ### Response: (Severity: 5), (Category: ROUTING), (Description: Information regarding all resource cleanup), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-TARGET_CFG_CREATE ### Response: (Severity: 3), (Category: MGBL), (Description: Nvgen client failed to create target config buffer. Configuration can not proceed.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-CONTEXT_CREATE ### Response: (Severity: 7), (Category: HA), (Description: During registration for memory notification, an internal error prevented the creation of an internal context structure. The calling function and detected error are displayed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTIO-4-WRITE_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The VTIO SPP plug-in failed when attempting to communicate between threads.), (Recommended Action: If any problems are seen, they may be rectified by restarting the spp process using the 'process restart spp' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-NOTIFD_INIT_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: The Notification Daemon server (notifd) failed to start correctly), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_SW-3-ERR_ATTACH_FSV ### Response: (Severity: 3), (Category: IP), (Description: The IPv6 NetIO component was unable to attach the required FSV before passing the packet to the IPv6 partner process. The Packet was dropped.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LM-3-LINKMON_ERROR ### Response: (Severity: 3), (Category: LIBRARY), (Description: PCI connections Errors.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-INVALID_REQUEST ### Response: (Severity: 3), (Category: OS), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-6-ENFORCE_INC ### Response: (Severity: 6), (Category: LICENSE), (Description: The licensed feature is enabled with appropriate licenses.), (Recommended Action: 'DEBUG') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-7-INCONSISTENT_VERSIONS ### Response: (Severity: 7), (Category: HA), (Description: An invalid combination of version numbers was encountered during table registration or table versioning. This is most likely due to a coding error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-3-SETUP_HANDLERS ### Response: (Severity: 3), (Category: IP), (Description: The IPV6 MA process failed to initialize various callback handlers for various synchronous and asynchronous events.), (Recommended Action: Restarting ipv6_ma may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-4-CONFIG_SCRIPT_TIMEOUT ### Response: (Severity: 4), (Category: MGBL), (Description: The config script exceeded the maximum allowed execution time and so must be terminated to ensure that no negative impact on the system is incurred through its usage. In order to recover, CCV must restart.), (Recommended Action: The problem may be caused by an error within the script itself. Attempt to address any problems within the script before proceeding. If further problems are seen, the cause of the timeout should be investigated, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-UIDB_THRESHOLD_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: The UIDB entry utilization for a specific LC has exceeded the default warning threshold (90 %)), (Recommended Action: Limit UIDB usage accordingly. This is a direct result of interface/sub-interface creation, either statically configured by user input or dynamically created by protocol action. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PQMON-6-QUEUE_HIGH_THRESH ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The amount of work queued into a software queue has crossed the high threshold (three-fourths of the queue size). This typically means that the owning process is blocked or CPU is under heavy stress and, hence, the owner process is unable to process the queued work items.), (Recommended Action: These messages are for the purpose of proactively alerting the operator to any potential issues that may arise from queue build-up on the software queues. If no impact (such as routing protocol flaps or traffic loss) is seen, these messages can be ignored.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-3-FIELD_ENTRY_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: OFA failed to create entry for the Group on this NPU.), (Recommended Action: The failure caould be because we ran out of available free entries for this Group on this NPU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-BADMSG ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospfv3 - show ospfv3 trace all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_NTP_LIB-7-EXIT_MESSAGES ### Response: (Severity: 7), (Category: IP), (Description: NTP process exits and restarts when it detects a failure. If the error does not persist it can be ignored.), (Recommended Action: None required if NTP process restarts and recovers.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-INSTALL_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: The installation of the virtual service failed.), (Recommended Action: Enable the Virt-manager trace logs and repeat the installation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-ASIC_RESET_REASONS ### Response: (Severity: 6), (Category: FABRIC), (Description: This message is seen when fabric ASIC require to be reset during a driver restart. \ The output contains the a bit mask depiction of all ASICs on the fabric board. \ 'Ready' and 'Reset' masks identifies the ASICs that are in ready or reset state. \ 'Halt', 'Not ready' and 'Init fail' provide additional information if the 'Reset' mask \ is non-zero.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT-4-STATS_ERROR ### Response: (Severity: 4), (Category: L2), (Description: An error occurred when attempting to retrieve results from the hardware.), (Recommended Action: If this error occurs only once, it may be safely ignored. Otherwise, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-7-ERR_SYSDB_EDM_REG ### Response: (Severity: 7), (Category: PLATFORM), (Description: Cpuctrl Sysdb Register EDM error), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDBUTILS-7-LOCKING ### Response: (Severity: 7), (Category: SYSDB), (Description: The client library has either failed to aquire or release a lock.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-3-ERR_ALLOC ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in CPUCtrl driver due to memory allocation), (Recommended Action: Restart the process using the CLI in the exec mode -process restart rodimus If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-NODE_KDUMP ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node's kernel is dumped to local harddisk or RP's harddisk.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-AUTHENTICATION_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: The IKE process was unable to authenticate its security association with its remote peer.), (Recommended Action: 'Contact the remote peer's administrator.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-3-MSG_ERROR ### Response: (Severity: 3), (Category: OS), (Description: The message received by the server had inconsistent values.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-7-SESSION_STARTUP_OK ### Response: (Severity: 7), (Category: MGBL), (Description: Debug message), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-MSG_VER_MISMATCH ### Response: (Severity: 3), (Category: OS), (Description: A msg from an application has different version format with current software.), (Recommended Action: The OBFL file should be saved to other place for later debugging, and then it should be removed to recover current situation. Please clear the OBFL files, as it might be because of corrupted records. CLI : admin clear logging onboard corrupted-files location If the issue is seen after clearing the files, please collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging 5. show tech-support sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-6-INFO_AUTH_SUCCESS ### Response: (Severity: 6), (Category: L2), (Description: PPPoE session is granted authentication success for a subscriber.), (Recommended Action: This is an informational message. It is not required any action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-GET_CTX_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: EINT driver got a packet but couldn't map a port to an idb context), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-BAD_UPDATE_MESSAGE ### Response: (Severity: 3), (Category: OS), (Description: The indicated error occured while processing an update from another node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_LSP_INPUT_Q_OVERFLOW ### Response: (Severity: 4), (Category: ROUTING), (Description: An incoming LSP or SNP pdu was dropped because the input queue was full), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS_MIB-3-ERR_ALLOC ### Response: (Severity: 3), (Category: OS), (Description: An allocation has failed.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-ERR_HW_MODULE_DPA_TCAM_INCONSISTENCY ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. If the hw-module command is used to configure the user defined TCAM key parameters, there will be inconsistency between the config in DPA and the hardware since the lc has already started the initalization process before this config gets to it. Needs attention with RSP reload.), (Recommended Action: System is inconsistent. Need to reload the RSP for new values to take effect. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-3-ACP_VRF_INTERFACE_CREATE_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: 'Autonomic network VRF has not been ' 'created on the interface'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PM-6-PACKET_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Generic info messages pertaining to service PM.), (Recommended Action: No action is required for this message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SATORI-3-PCIE_ATTACH_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: pcie attach has failed and process will respawn), (Recommended Action: The Procmgr process will automatically respawn up to a fixed number of times. Verify the process is running: 'show process procmgr location <>' If it is still non-operational, execute 'process restart procmgr location <>'. If it the process still fails to spawn, contact support with the required info. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRP-3-ERR_SOCKET_INIT ### Response: (Severity: 3), (Category: L2), (Description: Process encountered an internal software error. Process was failed to initialize socket. The process will automatically respawn up to a fixed number of times to try and recover.), (Recommended Action: Check if the linecard reported any other errors during the boot process as this error is normally associated with larger system issues. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-4-PEC_RELOAD_IGNORED ### Response: (Severity: 4), (Category: PLATFORM), (Description: An expansion card was attempted to be reloaded, but it is currently shutdown. So, the reload instruction was ignored. To enable a reload the expansion card needs to be brought up first (no shutdown) and then it needs reloading.), (Recommended Action: Bring up the PEC : 'no hw-module subslot 0/0/1 shutdown' Reload the PEC : 'hw-module subslot 0/0/1 reload') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-6-XFP_RETRY_EEPROM_RD ### Response: (Severity: 6), (Category: L2), (Description: The Reading of XFP EEPROM failed; Retry is attempted), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-4-INVENTORY_CHANGE_FAILURE ### Response: (Severity: 4), (Category: MGBL), (Description: A failure was encountered while trying to update the Central Config Validator (CCV) with information about the current inventory available in the system. Validation of configuration will still occur, but in situations where this depends on the system inventory the validation result may be incorrect.), (Recommended Action: The cause of the inventory change failure should be investigated, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDP-3-INIT_RETRY ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the UDP process attempts to retry one of its initialization tasks with a network layer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EM-7-EEMED_EVM_CREATE ### Response: (Severity: 7), (Category: HA), (Description: The event detector has failed to create an Event Manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-4-EXT_USB_FAULT ### Response: (Severity: 4), (Category: PLATFORM), (Description: The PRP detects a over-current condition on external USB port and it is disabled the port.), (Recommended Action: Remove and replace the external USB device Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-CF_OVF_ERR_FIA10 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA10 channel FIFO overflow error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-ENCAP_CONFLICT ### Response: (Severity: 4), (Category: L2), (Description: There is a conflict between the interface encapsulation and rewrite configuration and the CFM configuration. AIS or CCM packets cannot be sent from the interface or MEP mentioned in the message, for one of the following reasons: - CoS bits are configured, but there are no VLAN tags in which to carry them in the packet. - An attempt is being made to send packets inwards, but the interface is not configured in L2 mode. - The service is configured with a number of tags to use when sending packets, but either the packets are being sent outwards, or the encapsulation has fewer tags than the number specified.), (Recommended Action: Modify either the interface encapsulation a rewrite configuration, or the CFM configuration, so as to remove the conflict. For example, remove any MEP CoS configuration, or remove any service 'tags' configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-3-PTHREAD_MUTEX_UNLOCK_FAILED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TYPE6_CLIENT-3-UNREGISTER_NOT_ALLOWED ### Response: (Severity: 3), (Category: SECURITY), (Description: Type6 masterkey update is inprgress. Client has attempted an unregister now. This is not allowed from type6 as it can lead to inconsistencies.), (Recommended Action: If type6 is stuck in inprogress because client is not responding, use 'clear type6 client ' to recover. Note: this may lead to stale configurations in the client.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-6-PHASE2_RETRY ### Response: (Severity: 6), (Category: MGBL), (Description: The TTY Server found error in part of phase 2 initialization. Server is set not-to-restart, so retry. in particular if the aux port is running ksh then this should still be running unimpacted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FC-6-FW_OPERATION_INFO ### Response: (Severity: 6), (Category: INSTALL), (Description: Information about the firmware client operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_CLI-3-NO_MEMORY ### Response: (Severity: 3), (Category: OS), (Description: Not enough memory available in the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SE_INFRA_MGR-3-BIND_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: The message indicates the failure in binding the data.), (Recommended Action: Please provide the following logs: Copy the error message exactly as it appears on the console or in the system log. Issue the cmd command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the cmd output, call your Cisco technical support representative and provide the representative with the gathered information. - Show logging - show services secontroller trace reverse location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-ISM_PD_LIB_ERROR ### Response: (Severity: 3), (Category: INSTALL), (Description: Ism_pd_lib_error occurs while getting nodeid information, plane information and while reloading node. Please contact TAC for further details.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-1-ERR_HALT_VIA_FPGA ### Response: (Severity: 1), (Category: FABRIC), (Description: The specified device could not be halted using the FPGA register. Use the fabric ASICs internal register to halt the device. This message is meant to catch specific hardware failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-INFO_ISPF_DEPRECATED ### Response: (Severity: 6), (Category: ROUTING), (Description: Incremental SPF (ISPF) is deprecated. No action will be performed.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPG-7-STANDARD_DECODE_BAG_USED ### Response: (Severity: 7), (Category: MGBL), (Description: An internal data structure failed to be decoded in a fast manner and the slower, more complete decoding, has been used instead.), (Recommended Action: No action is required. This is an internal message used to track and improve efficiency of the system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-4-STANDBY_NOT_READY_REASON ### Response: (Severity: 4), (Category: HA), (Description: The named process has set the standby in a not ready state with the supplied reason.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_OOM ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal error encountered in RIP's OOM module. This may affect RIP's behavior only under low memory conditions; otherwise RIP will operate normally.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBIMGR-6-MBIVSN_STR_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: MBI Mgr general info, where both parts of the specifiable info are strings.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: B_SHIM_PARTNER-3-SVR_UBIND_ERR ### Response: (Severity: 3), (Category: L2), (Description: 'There is a software error when trying to unbind to IM.'), (Recommended Action: Check if IM is working fine or not by executing CLI 'sh process ifmgr location <>'. Try performing IM process restart by executing CLI 'process restart ifmgr location <>'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-7-DEBUG ### Response: (Severity: 7), (Category: MGBL), (Description: General debugging information for development and general diagnosis.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-CHKPT_ATTR_CREATE ### Response: (Severity: 3), (Category: OS), (Description: chkpt_create failed while creating an object in a chkpt table.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FLOWTRAP-4-BAD_ACTOR_INTF_DISABLED ### Response: (Severity: 4), (Category: OS), (Description: The punt flow trap sampler detected an excessive flow on an interface. This could result in a denial of service to other interfaces. Penalty-policing has been disabled by configuration so the interface will not be placed in the 'penalty box.'), (Recommended Action: No action necessary. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-MALLOC_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: System could not successfully provide the request memory block.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_CLI-3-EMWEB ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP CLI Agent was unable to carry out an EmWeb server function. The HTTP process may no longer be able to function correctly, and may need restarting if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of Secure Shell (SSH) and how is it configured in Cisco IOS XR? ### Response: Secure Shell (SSH) is used to provide secure and encrypted remote access to the router for management purposes. SSH is configured by generating a key pair, specifying the SSH version, setting the timeout and maximum authentication tries, and configuring VTY lines to use SSH as the transport protocol. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-SHMOO_FILE_DELETE ### Response: (Severity: 3), (Category: FABRIC), (Description: Removing the memory tuning file. Memory tuning will be automatically done on boot.), (Recommended Action: Collect the above mentioned logs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RASF-2-NO_RETRIEVER ### Response: (Severity: 2), (Category: ROUTING), (Description: This is a logic error in the construction of one of the ORA entities. The function to actually perform the retriever operation was not defined.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_2_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_2 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-5-PER_PREFIX_GLACIAL ### Response: (Severity: 5), (Category: ROUTING), (Description: Error while enabling/disabling per route accounting for a route), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP TTL security feature? ### Response: The BGP TTL security feature provides a lightweight security mechanism for protecting eBGP peerings. It uses the TTL field to verify that the peer is within a specified number of hops. Packets that exceed the hop count are discarded. It is configured with the neighbor ttl-security command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-DEBUGFAIL ### Response: (Severity: 4), (Category: SNMP), (Description: Failed to initialize support for the command 'debug snmp mib xxx', where 'xxx' is the MIB indicated in the error message. This could be due to a low memory condition or an internal software error. The result is that this command cannot be used.), (Recommended Action: Restart snmpd process.if still noticed this message check the state of snmpd process 'show process snmpd' and contact technical support representative. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDM_LIB-3-BARRIER_OVERFLOW ### Response: (Severity: 3), (Category: PLATFORM), (Description: Overflow occurred on buffer used to store client's write to hardware. This could cause losing some configure data after a hard reset. The lost data may be identified by checking what client process was writing to hardware during the reset), (Recommended Action: Check system sanity related the to card, since it possibly cause protocol/traffic packets drops.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-KERN_OBFL_MSG1 ### Response: (Severity: 4), (Category: MEDIASVR), (Description: This ios_msg is raised when an OBFL flash is not accessable.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_LONG_PKT_1_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress long packet detected on xaui-1 bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN_EA-3-DEST_NOT_SUPPORTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform does not support this destination.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-REPLACE_COMMIT_TRIGGER_FAILURE ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that install commit as part of the replace operation couldnt be triggered.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-NO_PLIM ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message informs the user that the linecard will be powered down because there is no PLIM inserted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-5-MAP_RESOLVER_REACHABILITY_CHANGE ### Response: (Severity: 5), (Category: IP), (Description: 'No route to reach map-resolver hence map-cache will not ' 'get resolved.'), (Recommended Action: 'Ensure ITR has connectivity to map-resolver.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: B_SHIM_PARTNER-3-SVR_BIND_ERR ### Response: (Severity: 3), (Category: L2), (Description: 'There is a software error when trying to bind to IM.'), (Recommended Action: Check if IM is working fine or not by executing CLI 'sh process ifmgr location <>'. Try performing IM process restart by executing CLI 'process restart ifmgr location <>'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHOWCMD-3-STD_MSG ### Response: (Severity: 3), (Category: SNMP), (Description: 'The failure pertains to show commands in snmp, when sending reciving the data' 'This does not indicate feature failures or issues'), (Recommended Action: 'This log does not indicate a system impact.' 'all show snmp CLI's for debugging purpose only' 'Recommend customer to re-try the command.' 'If there is no output, reconfigure the snmp settings and re-try') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-4-LSD_REPLY_FAILED ### Response: (Severity: 4), (Category: OS), (Description: The Linux Socket Database received a message from a client process, but was unable to send a response. The client process may remain blocked waiting for a response.), (Recommended Action: The scope of problems caused by this depend on the importance of the client process. As a first action, try restarting the client. If this is seen repeatedly, try restarting xlncd, but note that Linux datapath operation may be affected. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-BARRIER_FLOW_STARTED ### Response: (Severity: 6), (Category: FABRIC), (Description: Barriers started flowing on all the nodes/types.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HM-3-FPING_MISMATCH ### Response: (Severity: 3), (Category: HA), (Description: HA Health Monitor Fabric ping failed. When a received ping response does not match the transmitted ping, this indicates some kind of cell corruption or cell loss in the fabric or edges of the fabric.), (Recommended Action: If problem persist, it indicates the bad hw in the system. Please contact TAC for fault isolation. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How are VRFs configured for L3VPNs in Cisco IOS XR? ### Response: VRFs are configured using the 'vrf' command in global configuration mode. Various VRF attributes such as route distinguisher, import and export route targets are configured under the VRF configuration mode. Interfaces are associated with a VRF using the 'vrf' command under the interface configuration mode. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-4-CPLD_POWER_SEQUENCER_FAULT_OR_ALERT ### Response: (Severity: 4), (Category: PLATFORM), (Description: The fabric power sequencer detected a temperature or power alarm.), (Recommended Action: An alarm was detected. If a critical alarm is detected node will be shutdown. Please collect logs mentioned in required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the Local Packet Transport Service (LPTS) and what is its purpose? ### Response: The Local Packet Transport Service (LPTS) is a feature that helps protect the control plane and management plane from denial-of-service (DoS) attacks. It uses a combination of an access control list, a rate limiter, and flow classification to police local traffic destined to the router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-7-DLINK ### Response: (Severity: 7), (Category: ROUTING), (Description: An internal software error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MXPDRVR-6-NCS1K_PROV_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates success of slice provisioning), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-PAR_SERR_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Single bit mem parity error on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_PLATFORM-7-ERR_GEN ### Response: (Severity: 7), (Category: ROUTING), (Description: MFWD-PLATFORM library encountered error during setup. The init setup will be retried for finite number of retries.), (Recommended Action: *RECUR) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_LIB_PLMGR_SUPP-3-LTRACEOPEN ### Response: (Severity: 3), (Category: QOS), (Description: Qos lib ltraces will not work as the ltrace initialization failed. The failure may be due to one of the following reasions. 1. Due to invalid magic number in existing buffer 2. Due to invalid length field in existing buffer 3. Due to failure in allocating memory 4. Due to unexpected system error), (Recommended Action: Collect the console logs along with the information specified under the component required_info and call your Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-UNMAP_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Unmapping shared memory tables of AIB Failed.' 'This will not effect the process.' 'This operation is optional'), (Recommended Action: 'ISSU manager will use some other API' 'If the issue persists ' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHDLCDLL-3-ERR_PKT_ENCAP ### Response: (Severity: 3), (Category: L2), (Description: The encapsulation of an HDLC packet failed for the network protocol with the ethernet type code specified. The packet has been dropped.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-7-FUNC_DEBUG ### Response: (Severity: 7), (Category: OS), (Description: --), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-4-IM_CONN ### Response: (Severity: 4), (Category: ROUTING), (Description: An error occurred when FIB tried to communicate with IM.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_FWD-2-NO_MEM ### Response: (Severity: 2), (Category: ROUTING), (Description: The requested operation could not be accomplished because of a low memory condition.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED_LIB-7-MSG_CONNECT ### Response: (Severity: 7), (Category: OS), (Description: An attempt to connect to the lead placed server failed with the specified reason. It may be the case that placed server had been restarted.), (Recommended Action: Collect the function name and traceback information. show commands: Issue 'show proc placed' to check if placed has restarted. Collect show tech placed, show tech sysmgr and forward to your next level of technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-LSP_WRAP ### Response: (Severity: 5), (Category: ROUTING), (Description: All the LSP Wrap enabled Flex LSPs using the specified interface \ as outgoing interface has changed their LSP-WRAP status.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGPTE_LIB-2-DATA_QUEUE_FULL_PROCESS_RESTART ### Response: (Severity: 2), (Category: ROUTING), (Description: The IGP-TE inter-process message queue has remained full for an extended period of time. The IGP process has been restarted to recover.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROLLER_ODU-3-DLL_OPEN_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A failure occurred opening a dependent DLL and loading its symbols. The process is unable to run.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-KDUMP_MNT_FAILED ### Response: (Severity: 3), (Category: DRIVER), (Description: To start the kernel core dump operation, the filesystem used to store the core file has to be mounted first. This mounting operaiton is failing and it is preventing the creation of the host kernel core file.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-3-MSGRPLY_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: BFM encountered message reply error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKS_SRVR_ENGINE-3-ERR_2_PARAM ### Response: (Severity: 3), (Category: SECURITY), (Description: SKS server exp error message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-3-RULES_DUPLICATE_ID ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Multiple rules with the same static id were found in rules files. Every rule should have exactly one static id assigned to it.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-TARGET_CFG_LOCKERR ### Response: (Severity: 3), (Category: MGBL), (Description: Nvgen client failed to obtain exclusive lock for this session. Terminate the other open sessions and try again.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_FPOE_DB_CORR_ECC_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast FPOE correctable ECC error on link 2), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_RACK_CLUSTER_UNSUPPORTED ### Response: (Severity: 3), (Category: OS), (Description: more then 2 Rack cluster not supported.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MANSDORF-6-GENERIC_EVENT ### Response: (Severity: 6), (Category: PLATFORM), (Description: A generic event logs in MANSDORF layer.), (Recommended Action: No action is required. This is info message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ET0_INTR_HDR_CSUM_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ET0_INTR_HDR_CSUM_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-OOR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Network Processor Provisioning experienced an Out-of-resource condition that could not be reported back to provisioning agent for recovery/back-off Loss of configuration and data could occur.), (Recommended Action: Loss of configuration and data could occur. Revisit recent provisioning or route-update events to see if router resources have been exceeded.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_IM_REG_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to register for notification of the specified changes on the specified interface and protocol. This may happen in case of ifmgr not ready to process the request. For example ifmgr restart. This may be an internal programming error, but is most likely to be a resource starvation problem.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider disabling and reenabling the interface within IS-IS configuration, or restarting the IS-IS process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-EDM_ENCODE_FAILED ### Response: (Severity: 3), (Category: OS), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The data requested could not be encoded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCCLIB-3-ERR_HW_BIST ### Response: (Severity: 3), (Category: PLATFORM), (Description: BIST failure,update the state at block level.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: deflate-3-output_error ### Response: (Severity: 3), (Category: OS), (Description: The multiple file compression output cannot be directed to stdout), (Recommended Action: Please check command syntax for error if the error is from a user CLI Please capture show log and error messages if the error is not due to user entered CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-SYSMGR ### Response: (Severity: 4), (Category: L2), (Description: ELMI encountered an error while communicating with SysMgr. The error message describes what operation has failed and why it failed. This is a fatal error and the ELMI process will abort and be restarted to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between installing a package using the install add command versus the install activate command? ### Response: The 'install add' command copies the package to the router's storage but does not make it active. The 'install activate' command is used to make the package active on the router. Packages can be added and activated in a single step using 'install add' followed by 'install activate' in a single command line. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_CONFIG-7-ERR_TUPLE_UNPACK ### Response: (Severity: 7), (Category: OS), (Description: Failed to unpack tuple details), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-2-INIT_FAILURE ### Response: (Severity: 2), (Category: PLATFORM), (Description: The initialization of a needed resource failed at process startup, therefore exiting the process. The system will attempt automatic error recovery by restarting the mbi-hello process several times. If the error does not correct itself, this card will then be rebooted.), (Recommended Action: Please collect the following information and contact your Cisco technical support representative. 1. The console output of the active RSP from user login till the end. Please make sure the above error message(s) are included. 2. (admin)#show install trace mbi-hello location Note: The above command may not work if the mbi-hello process keeps restarting. However, it can provide valuable information if it can be collected. 3. The output of the following CLI commands:) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTR6 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TYPE6-3-TRACE_INIT_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: Type6 server could not initialize the event tracing module), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-3-UNEXPECTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: An unexpected condition encountered. This is not necessarily an error, but may help with debugging other problems elsewhere!), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-QDR_MEM_SELFTEST_FAIL_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: QDR memory self test failure on bridge instance-3.), (Recommended Action: Please reload the board using the command 'reload location <>'. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_MGR-3-DRVR_SERVICE_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: SFE driver could not initialize due to above error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-2-THERM_OVERT_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Interrupt controller driver detected a thermal over temperature), (Recommended Action: Ensure the fans are working & the board is not overheated. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-FILEOPEN ### Response: (Severity: 4), (Category: MGBL), (Description: The file specified for reading instructions from, or writing output to, when MDACon was started, cannot be found. The most probable reason is that an incorrect incorrect name or path was supplied.), (Recommended Action: Check that the file name sor path upplied was correct. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Rx alignment loss on XAUI to NPU-0 interface on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between a stub area and a totally stubby area in OSPF? ### Response: A stub area does not accept external routes (Type 5 LSAs) but does allow summary routes (Type 3 and 4 LSAs) from other areas. A totally stubby area does not allow external routes or summary routes from other areas. The only way for traffic to get routed outside the area is a default route generated by the ABR. This further reduces the size of the routing and topology tables within the area. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_TEST_ONLY ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA hit some code that it shouldn't be possible to hit except during testing. This must be related to a programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-NOTIFOID_FAILED ### Response: (Severity: 3), (Category: SNMP), (Description: Every trapstring supported by the 'snmp host' command corresponds to one or more notification OIDs. Each of these notifications will have zero or more varbinds that are carried as payload - each MIB tells snmpd about these varbinds so that a 'notification view' can be built for them. An extra varbind - sysObjectID - is required to be sent with all v2c notifications. This message indicates that an attempt to register this varbind failed. Sending v2c notifications for the trapstring specified in the error message may fail. You can workaround this by not specifying any trapstring in the 'snmp host' configuration - this will enable all notifications for that destination.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_EVM_CONN_SETRETRY ### Response: (Severity: 3), (Category: ROUTING), (Description: Error while setting event connection setretry. This will cause ipv4_mfwd_partner and ipv6_mfwd_partner processes to exit. When process exists, sysmgr will automatically respawn the process for some number of times. If it still fails, process remains in the exit state. This will impact multicast forwading.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_9_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_9 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_2_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser bias greater than or equal to the high laser bias warning threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_DYNREG-3-MODIFY_AP_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered as we were looking up data for the above attach point. The operation in question did not succeed, and thus the policy_repository could be in an inconsistent state.), (Recommended Action: Restart the policy_repository process and check for re-occurence of issue If problem persists, the please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-BUS_ADRALN ### Response: (Severity: 4), (Category: OS), (Description: Bus error generated due to invalid address alignment. Program is trying to read or write data that does not fit the CPU's memory alignment rules.), (Recommended Action: No action required.Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_DIR-3-CHKPT_READ_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The ISSU infrastructure has identified that a sysadmin ISSU operation has failed. The system must be reloaded in order to recover to the committed version.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_2_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROLLER_ODU-3-CTRLR_INIT_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A failure occurred during initialization with a necessary service for a particular interface type. The process is unable to run.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_MPLS_EA-3-ERR_INFO_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in MPLS EA. Typically, this is an error where the software fails to initialize or programming of forwarding feature fails. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef mpls trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMORB_XMLAGENT-3-CRYPTO_DEACT ### Response: (Severity: 3), (Category: MGBL), (Description: The crypto pie is deactived or removed while xmlagent is running in ssl mode.), (Recommended Action: Unconfigure xmlagent or configure it to run in non-ssl) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSDIR-1-OPERATION_QS_RUN_DONE ### Response: (Severity: 1), (Category: INSTALL), (Description: The Quickstart Run operation has completed successfully.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to set RSVP explicit path for TE tunnel? ### Response: To set an RSVP explicit path for a TE tunnel, use the 'explicit-path name' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#explicit-path name Path1 RP/0/RSP0/CPU0:router(config-expl-path)#next-address 10.1.1.2 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_THREAD_MUTEX_UNLOCK ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error during unlocking of a RIP resource.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-NO_ACT_FAB_ALERT ### Response: (Severity: 1), (Category: FABRIC), (Description: No active fabric signal detected on FIA instance.), (Recommended Action: Please reload the board in the next maintenance window. If this fault happens on a single FIA/slice, and '(admin-config)#fault-manager datapath port shutdown' is configured, the interfaces for this slice would be shutdown. If the fault could not be cleared after card OIR, please RMA the card. 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_13_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-OOR_REGISTER_WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_CHAR_ALIGN_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-0 char alignment error on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-ERR_PROGRAM_ERRORED_POLICER ### Response: (Severity: 7), (Category: OS), (Description: An internal error was detected when trying to program the flow policer.), (Recommended Action: When this issue happens, it will trigger an automatic restart. Check the status of Metro IPC Server because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: libpcmcia_linux-7-OPEN_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Open of file failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-REG_EXPIRED_CLOCK_CHANGE ### Response: (Severity: 3), (Category: LICENSE), (Description: The system clock has been changed so that it is now outside the valid registration period. If the clock is reset to a value inside the registration validity period within one hour smart licensing will continue function normally. If the clock is not reset the device will become un-registered and a new id token will need to be obtained to re-register the device. The registration validity period is defined by the start and end date in the id certificate. use 'show tech license' to get the id certificate information.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRP-3-ERR_MEDIA_WRAP ### Response: (Severity: 3), (Category: L2), (Description: The specified side of the interface has wrapped or unwrapped for the given reason. There is/was a fault (or user request) on the ring causing potential loss of traffic/bandwidth.), (Recommended Action: Clear the cause of the fault/wrap. Use the 'show srp ips' and 'show srp failures' CLI to determine the root cause of the fault (if still present).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATS_INFRA-3-ERR_INFRA_MAP ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in stats infra component. The error occurs if the pointer to the root page for the stats infrastructure is not received .), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_13_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-CANNOT_GET_PROCNAME ### Response: (Severity: 7), (Category: INSTALL), (Description: A process' name cannot be determined, so the current request or operation will not be able to proceed successfully.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAP_LISTEN-3-EVENT_CONN_MGR_FAILURE ### Response: (Severity: 3), (Category: ROUTING), (Description: This indicates that the SAP listener packet handling process failed to open connection to Connection Manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging processes sap_listen error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging processes sap_listen error output, call your Cisco technical support representative and provide the representative with the gathered information. Using the Job ID from the above command, please run the following command: Copy the error message exactly as it appears on the console or in the system log. Issue the show evm trace jid errors command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show evm trace jid errors output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show sap trace detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show sap trace detail output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HPI-7-DEBUG_INFO ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-MISSDESTNAME ### Response: (Severity: 4), (Category: MGBL), (Description: The command entered requires a destination object name or path and one was not supplied.), (Recommended Action: Use the help command to determine the correct usage for this command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX8508-3-WARN_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The message can be displayed whenever there is a driver initialization error.), (Recommended Action: The driver process will re-start and complete initialization of the switch device. However, if this message is seen for more than 5 times than please reload the card using -hw-module location <> reload and check if the message still occurs in subsequent reload.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_12_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_12 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LIC_MGR-3-EULA_ACCEPTED ### Response: (Severity: 3), (Category: OS), (Description: The end user has accepted an end user license agreement.), (Recommended Action: This message is informational.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the default behavior of the running configuration in IOS XR? ### Response: By default, the running configuration in IOS XR is not saved automatically. Changes made to the running configuration are lost on a reload unless explicitly saved to a file using the 'save configuration' command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-4-CHKPT_RESTORE_FAILURE ### Response: (Severity: 4), (Category: SECURITY), (Description: Encountered a checkpoint recovery failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BLWM-4-PULSED_FLUSH_FAILED ### Response: (Severity: 4), (Category: OS), (Description: A BLWM-enabled client failed to flush the batched LWM requests. This is most likely because the server process restarted. Wait for client to reestablish connection with server and flush the batched requests again.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-ABORT_INCOMPLETE_INSTALL ### Response: (Severity: 3), (Category: INSTALL), (Description: A previously requested install operation that was incomplete was attempted to be applied. However the operation was detected as being before any state had changed so was aborted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_VCM-3-SUB_IF ### Response: (Severity: 3), (Category: L2), (Description: Unexpected error on the sub-interface), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-3-CHDIR_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Chdir failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check the card is inserted properly to the slot if it is an externally accessible device. Submit ddts if the card is internal device or inserted properly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_TOPAZ-7-INFO_SHM ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered a change in the shared memory region parameter.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-DEVICE_ACCESS_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter device access), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMDR-6-TEST_CLIENT_FEED_EVENT ### Response: (Severity: 6), (Category: OS), (Description: Status information while asking all registered clients to f try to put messages with PRIxPTR or PRIdPTR, it's throwing errorseed the event.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-SYSCALL ### Response: (Severity: 7), (Category: HA), (Description: A system call failed. The calling function, the failed call, and error are displayed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-CANT_READ ### Response: (Severity: 7), (Category: INSTALL), (Description: PIE file appears to be damaged. Package read failed due to network connectivity issue.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-2-LEAD_CONFLICT ### Response: (Severity: 2), (Category: TOPOLOGY), (Description: System Admin Manager has detected a Lead Conflict.), (Recommended Action: No action is required. The System will recover itself from this state.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-EBS_OC_PKT_TOO_SHORT ### Response: (Severity: 2), (Category: PLATFORM), (Description: EBS from FIA packet too short error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-FINDDATA ### Response: (Severity: 4), (Category: MGBL), (Description: An error occurred invoking an MDA function. The details are in the error string), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-DEBUG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Error encountered in debug module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-2-PLIM_NOT_PRESENT ### Response: (Severity: 2), (Category: PLATFORM), (Description: PLIM is not detected by lc fpga.), (Recommended Action: Check IF plim exists in the slot. If it does then reseat the plim properly and make sure it is properly inserted) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-1-DISK_ALERT ### Response: (Severity: 1), (Category: HA), (Description: When some monitored disk's usage is above 99%.), (Recommended Action: The indicated disk device may be running out of space. Determine if there are unneeded files on the disk.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-5-NOTICE ### Response: (Severity: 5), (Category: PLATFORM), (Description: This is a notice about a normal but significant event.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-7-FAIL_EDM_OPEN ### Response: (Severity: 7), (Category: PLATFORM), (Description: Inventory Manager is not able to open a EDM connection channel with the event manager to read/write the inventory details from the SYSDB database.), (Recommended Action: No action needed. It should auto recover) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SGT_FIFO_OFLOW_0_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress sgt fifo overflow on xaui-0 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-7-MP_CORE ### Response: (Severity: 7), (Category: L2), (Description: An error occurred in PSE MP Microcode Driver which required exiting (and, hence, restarting) the process. This message records the location of the MP Core File.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message on the console and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-6-UPGRADE_STARTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message indicating that the Canbus Controller firmware on the specified loation is going to be upgraded with the image at the specified path.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-6-ERR_ASIC_OOR ### Response: (Severity: 6), (Category: FABRIC), (Description: Fabricq encountered an out of resources error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-1-I2C_TIMEOUT ### Response: (Severity: 1), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMIAP-3-CHKPT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: A call to checkpoint function failed for the virtual ip address of that vrf), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-6-OPTICS_REMOVAL ### Response: (Severity: 6), (Category: L2), (Description: Optics module has been removed. %d - indicates the bay number), (Recommended Action: None. This is an informational message only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_HQ_SEQ_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue sequence error on XAUI 0 HQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-3-ERR_INTERNAL_SW ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID Server encountered the annunciated SW error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-6-BADCHKSUM ### Response: (Severity: 6), (Category: ROUTING), (Description: OSPF has detected a checksum error in an LSA due to memory corruption.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show ospf bad-checksum) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-INIT_ACL_CONF_MGR_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failed to initialize callback functions from ACL configuration manager to perform hardware resource checks and ACE resequencing.), (Recommended Action: No action is required. Process will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If restart din't fix the problem) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-CONFIG_SET ### Response: (Severity: 3), (Category: ROUTING), (Description: A speaker or the bRIB failed to process a configuration change.), (Recommended Action: Please try to recover by rolling back the last config change and re-applying it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-3-INIT_CHECK_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failure occured while checking if PM Library is initialized due to one of the following reasons: 1. Invalid Arguments passed to function 2. Unable to find information pertaining to requested window 3. Error occured while fetching shim information), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-TSPI_ASYNC_FIFO_H72_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: TxSPI async FIFO high 72bits data single bit ECC error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-6-ENFORCE_DISABLED ### Response: (Severity: 6), (Category: LICENSE), (Description: Smart Licensing is disabled.), (Recommended Action: The customer should install license on router before enabling licensed feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-7-MSG_QUEUE_LONG ### Response: (Severity: 7), (Category: OS), (Description: --), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-UNKNOWN_ERROR_TYPE ### Response: (Severity: 4), (Category: INSTALL), (Description: An incorrect parameter was passed to the error reporting function. The errors for this install operation will not have been reported correctly.), (Recommended Action: This impacts only the error logging for the current install operation and has no impact on functionality. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_4_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-4-REMOTE_ACCESS_MAIN_PORT_FAILURE_CLEAR ### Response: (Severity: 4), (Category: L2), (Description: ICCP-SM has recovered from the remote access failure and has attempted to recover the ports in the redundancy group.), (Recommended Action: This message may not require any action. However the show l2vpn iccp-sm group group-num command may be used to verify the state of the ICCP-SM interfaces. Reference the L2VPN ICCP-SM section of the IOS XR documentation for details on core isolation failures and related configuration commands.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-I2C_FAILURE_PM_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: An I2C error was encountered when attempting to access the fault / alarm information of a Power Module.), (Recommended Action: Try doing restarts of below process admin process restart envmon loc <>. admin process restart i2c_server loc <>. Location is from the node on which this ios_msg is seen. If the issue still persists collect required_info) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-USER_DEF_TCAM_KEY_PARAM_MISSING ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The ACL match field or action mentioned in the error string is not configured in the TCAM using the hw-module command.), (Recommended Action: Program the match field or action in the TCAM Key using the hw-module command. Reload the LC. Attach the ACL.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_DEBUG-3-LTRACE_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: Ltrace library initialization failed), (Recommended Action: Please contact Cisco TAC for support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCCLIB-3-ERR_SW_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: software initialization error, due to error in rcc library intialization. The error message has detailed information.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-4-FORCE_DISABLED ### Response: (Severity: 4), (Category: MGBL), (Description: An error was encountered while the Central Configuration Validator (CCV) was initializing. Attempts to modify system configuration while CCV is disabled will not be validated.), (Recommended Action: The process restart should be investigated, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-4-CONNECT_WARN_AN_USING ### Response: (Severity: 4), (Category: SERVICES), (Description: 'This interface will be used by autonomic-networking.To enable other ' 'features disable autonomic-networking on this interface using ' ''no autonomic connect' command.'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-6-PRODUCT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Product info), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_AAA_ATTR ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the AAA attribute service. The error message describes what operation has failed and why it failed. The most likely reason for this is low memory resource or a programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. In many cases, PPP MA will recover by itself. If it does not then restarting the process should help. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP-6-PORT_LOOPBACK ### Response: (Severity: 6), (Category: L2), (Description: A PDU has been received on a port which was identical to that sent out of that port. This suggests that the port may be looped-back into itself.), (Recommended Action: Check the port wiring and whether loopback is configured on the port.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_15_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_15 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-6-STATE_CHANGE ### Response: (Severity: 6), (Category: LICENSE), (Description: The platform licensing client is transitioning from one state to another.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_1_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-ERR_DLL_SYM_FAILED ### Response: (Severity: 3), (Category: FABRIC), (Description: Fail to load the library. Check the the symbol exit in library or not '), (Recommended Action: check the library for the symbols) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-INV_MSG_TYPE ### Response: (Severity: 3), (Category: SYSDB), (Description: Message type received by SysDB is invalid or unknown.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-4-HEALTH_MONITOR ### Response: (Severity: 4), (Category: FABRIC), (Description: Fabricq driver monitors the ASIC every 5 seconds to look for any problems. If an error is reported momentarily, it could be a false positive seen during a transient state, or during oversubscription. In case, the error is seen repeatedly, please contact TAC support.), (Recommended Action: If the error persists, please contact TAC suppport.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HBAGENT-4-GET_THREAD_SCHED_FAILURE ### Response: (Severity: 4), (Category: PLATFORM), (Description: Unable to get thread information to set new priority. Proceeding with default priority, however in a high CPU consumption, this node's heartbeat pulse may get lost, causing this node to get reloaded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_EA-3-ERR_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, error information), (Recommended Action: Please collect the console log and CLI history (show cli history detail loc <>). Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-6-AGENT_DEREG_SUCCESS ### Response: (Severity: 6), (Category: LICENSE), (Description: Smart Licensing deregistration successful.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-COMPRESS_OFF ### Response: (Severity: 6), (Category: OS), (Description: Compress library initialization for the file failed. The file will become uncompressed one with '.Z' suffix.), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_RM-2-NOMEM ### Response: (Severity: 2), (Category: L2), (Description: Memory on the router is critically low. %d - amount of memory that is tried to be allocated), (Recommended Action: Check for memory conditions in the system. LC reload alone can recover from this situation. All info to be collected before the reload.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-QUEUE_LIMIT_OVER ### Response: (Severity: 7), (Category: OS), (Description: The destination queue is full. New enqueue request will be discarded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-BITS_MODE_NOT_SUPPORTED_IN_HARDWARE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The synchronization ports 0/1 are for BITS mode, but this mode is not supported on this platform), (Recommended Action: Do not attempt to configure BITS on RP clock interfaces 0 and 1) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RASF-2-NO_CMP_RETRIEVER ### Response: (Severity: 2), (Category: ROUTING), (Description: This is a logic error in the construction of one of the ORA entities. The function to actually perform the compare retriever operation was not defined.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: The FIA driver failed to initialize the device resulting in the restart of the FIA driver process. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.), (Recommended Action: Verify that the fia_driver is up and running by executing the following command at the CLI of the active RP: 'show process fia_driver location < >' If it is still non-operational, enable the following debugs of the FIA driver process: eio All EIO library events error Errors in the driver fatal Fatal errors which cause driver to exit info All informational events init Initialization events Restart the driver by executing the following command at the CLI of the active RP: process restart fia_driver loc If the problem persists, this could be indicative of a hardware failure and it is recommended to run the field diagnostics on the failing MSC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_STATIC-4-ERR_STATIC_LABEL_DISCREPANCY ### Response: (Severity: 4), (Category: ROUTING), (Description: To clear label discrepancy), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_5_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias less than or equal to the low laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-3-MUTEX_OP_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: --), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-5-TMP_PATH_FULL ### Response: (Severity: 5), (Category: OS), (Description: /tmp/dumper is not available because it is full of files still being transferred.), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-5-OS_IMAGE_SIZE_ERR ### Response: (Severity: 5), (Category: L2), (Description: The size of the SPA OS image is too big.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ALPHA_DRIVER-2-CARD_RELOAD_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: The Alpha Driver attempt to reload RP has failed. Please reload the card.), (Recommended Action: This log is just to notify that there has been a failure when we attempted to reload the chassis. Please perform a manual RP reload.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_DAPS ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the DAPS address pool service. The error message describes what operation has failed and why it failed. The most likely reason for this is a connection problem with the DAPS service, but the error could also be caused by low memory resources or programming error.), (Recommended Action: Consider restarting the PPP MA process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XFP-3-HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected an XFP Tx power greater than or equal to the high Tx power warning threshold. The XFP is the pluggable optics on the line cards. The Tx power threshold values are read from the XFP.), (Recommended Action: Verify that the device is properly inserted. Replace the XFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-ING_L4_ARRAY_UFLOW_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: L4 array underflow on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-3-CARDSTATE_INCONSISTENT ### Response: (Severity: 3), (Category: TOPOLOGY), (Description: There is a mismatch in state between cluster manager and shelf manager this may cause system in-stability), (Recommended Action: execute - show tech-support spi - and contact cisco support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_FGID_WRITE ### Response: (Severity: 3), (Category: FABRIC), (Description: One or more ASICs for the stage on the fabric card are in being reset. Hence this multicast FGID write operation for the specified stage is aborted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-BADFILTER ### Response: (Severity: 4), (Category: MGBL), (Description: An invalid filter name was entered for the related class.), (Recommended Action: Use the classinfo command to get more information about available filters for a given class. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-4-PD_COMPONENT_ERROR ### Response: (Severity: 4), (Category: MEDIA), (Description: PD component returned error for nvram classic_rommon_setvar function call), (Recommended Action: Nothing needs to be done) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-7-ERR_LWM_REPLY ### Response: (Severity: 7), (Category: PLATFORM), (Description: ClkCtrl LWM reply error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-3-QSM_NOTIFICATION_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Reddrv had problem to broadcast dead node name notification.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AIB-4-SHM_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: AIB uses shared memory to store adjacencies, but encountered an error when trying to initialize it. The process will attempt to recovery by restarting. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: This shows that there are underlying system level problems, so review all recent unsolicited errors. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_HFR-7-ERR_THREAD_ATTRIBUTE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while setting the thread attribute during the process initialization sequence. This is crucial for the process and is automatically restarted on this failure.), (Recommended Action: If the problem is experienced only by this process in the system, restart the fabric server process by executing the following command at the CLI of the active RP: process restart fab_svr location If problem either persists (following a process restart) or also noticed on other processes then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDLC-6-MSG_BCDL_THROTTLED ### Response: (Severity: 6), (Category: OS), (Description: BCDL consumer is not processing the messages from enqueued by bcdl library, causing the CBP buffer state to be critical.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-7-ERR_EVM_NOTIFY ### Response: (Severity: 7), (Category: PLATFORM), (Description: ClkCtrl Event Manager notify error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-SYSDB ### Response: (Severity: 3), (Category: OS), (Description: An internal sysdb function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-7-EVM_EVENT_BLOCK ### Response: (Severity: 7), (Category: OS), (Description: The event infrastructure will ignore this error and continue to wait for the next event. If this error is seen repeatedly, the process may not be able to function and will need to be restarted.), (Recommended Action: Collect the output of show tech-support, show processes , show memory, debug event-manager attach job <> and show watchdog memory-state from the location the error message comes from. If the error message doesn't persist, it can be ignored. If the error message persists,call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_EDM-3-DATALIST_SET_MORE_FLAG ### Response: (Severity: 3), (Category: ROUTING), (Description: A client has requested information through SysDB from OSPF. During execution of the request an attempt to set a flag indicating there is more data for the client failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_4P_OC192-3-MEM_ERR ### Response: (Severity: 3), (Category: L2), (Description: fail to allocate memory.), (Recommended Action: sysmgr would restart the process. show process memory <> to find out whehter there is potential memory leak show memory <> to confirm system memory goes low) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-NODE_SPECIFIC_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that an operation specific to a node has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-SSM_FAIL ### Response: (Severity: 4), (Category: L2), (Description: The quality level of the source has been changed to or from FAIL. The SSM Failed alarm occurs when the synchronization status messaging received by the device fails. The device is set up to receive SSM, but the timing source is not delivering valid SSM messages.), (Recommended Action: 1. Verify that SSM is enabled on the external timing source. 2. If timing is enabled use an optical test set to determine that the external timing source is delivering SSMs. 3. If the alarm does not clear contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-3-SM_MISMATCH ### Response: (Severity: 3), (Category: DRIVER), (Description: ESD detected inserted optics does not match with details in cluster layout.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: c2c-3-ERR_SW ### Response: (Severity: 3), (Category: PLATFORM), (Description: The C2C common library encountered an error which it cannot resolve.), (Recommended Action: An error would be reported to the client application which should handle this condition appropriately. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of Cisco IOS XR Syslog in monitoring and troubleshooting? ### Response: Cisco IOS XR Syslog is a logging mechanism that allows the router to generate messages about system events, errors, and status changes. These messages can be used for monitoring, troubleshooting, and auditing purposes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_6_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_6 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-3-HW_UT_DRIVER_ATTACH_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Driver attach has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLDR-3-PARTNER_IS_DOWN ### Response: (Severity: 3), (Category: PLATFORM), (Description: This node has detected its partner has gone down.), (Recommended Action: There is no action required. The system should recover by undergoing a switchover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_PW_INTR_HDR_PRS_SOP_EOP_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_PW_INTR_HDR_PRS_SOP_EOP_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGV6_SERVICES-7-GENERIC_INFO ### Response: (Severity: 7), (Category: PLATFORM), (Description: The message is used to report generic info about Services CGV6 SERVICES.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-IN_BUF_CRC_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected excessive input buffer CRC error on link 2), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. Also, check for any damage to the card and its backplane connectors. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_CFEC_BDI_DEM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-SETSOCKOPT_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS encountered an error whilst configuring the socket it uses for network I/O. As a result the socket is unuseable and IS-IS cannot perform I/O. IS-IS will attempt to recover by closing the current socket and schedule an attempt to reconnect.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.. Consider restarting the IS-IS process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to enable RSVP on a Cisco IOS XR interface? ### Response: To enable RSVP on an interface in Cisco IOS XR, use the 'mpls traffic-eng interface' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#mpls traffic-eng interface GigabitEthernet0/0/0/0 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EDRM_DLL-3-CLIENT_INIT ### Response: (Severity: 3), (Category: L2), (Description: Initialization of the DLL failed for the client due to indicated reason.), (Recommended Action: None. The initialization will be retried automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-3-REGION ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: bfm encountered an error and is not able to recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-COPY_FILE ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the Package infrastructure is behaving incorrectly. A file involved in the current request or operation could not be copied. This may impact install infrastructure functioning.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ST16550-3-SCHED_PRIORITY_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The ST16550 UART driver was unable to raise the priority of the interrupt handler.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_DIR-3-AGENT_MOD_TO_ORCH_MSG_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: The Agent module encountered an issue while attempting to send a message to the Orchestrator module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-INIT ### Response: (Severity: 3), (Category: OS), (Description: An NRS Server hit an error from which it could not recover during initialisation and is restarting to continue normal operation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-SWITCH_BACK_TO_DEFAULT_NNS_ERROR ### Response: (Severity: 4), (Category: INFRA), (Description: XLNCd runs in the default linux network namespace. However, in order to perform some system calls, XLNCd must switch namespace. After performing the calls, XLNCd will switch back to the default namespace, but this has failed, and XLNCd is now running in the wrong namespace.), (Recommended Action: If the problem persists, restart the process. If the problem persists through process restarts, If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HOSTNAME_SYNC-4-NODE_ROLE_CHNG_REG_FAILED ### Response: (Severity: 4), (Category: OS), (Description: Failed to register to sysmgr for node role change notification.), (Recommended Action: 'process restart hostname_sync') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-4-NETIO_OUTPUT_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: CLNS was not able to send a packet to NetIO. This could be because of communication problems between CLNS and NetIO.), (Recommended Action: If this message is seen during transient conditions, for example when NetIO is restarting either because of install operation OR because NetIO crashed then it is not harmful unless you see ISIS adjacencies dropping. If it is seen under steady state conditions or re-occur then please contact cisco-support. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-3-INVALID_BIND ### Response: (Severity: 3), (Category: SYSDB), (Description: A SysDB client tried to bind to an unsupported path. This may cause unexpected client behavior.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-4-INITIALISATION_FAILURE ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the process. This resulted in the restart of the process.), (Recommended Action: The process will automatically exit and will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_ALL_FT_REMOVED ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when all the fantrays are removed from the satellite. Satellite chassis shutsdown after two minutes from the time alarm is rasied.), (Recommended Action: Please insert at least one fan tray into the satellite chassis) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_UV-3-ERR_PROC_READY ### Response: (Severity: 3), (Category: ROUTING), (Description: The ospf_uv process was unable to signal process ready to sysmgr.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM_MLDP_LIB-3-MLDP_PROD_FAIL ### Response: (Severity: 3), (Category: IP), (Description: An error occurred while processing the request on the pim mldp producer. The producer received an unkown message type or an unexpected request.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show mlib trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show mlib trace error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show pim trace mldp command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show pim trace mldp output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show buffers command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show buffers output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-RELOAD_NODE_INFO ### Response: (Severity: 6), (Category: INSTALL), (Description: The installation required a reload of the pID's node, and this is now going ahead.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-CB_OFF_ALARM ### Response: (Severity: 4), (Category: PLATFORM), (Description: Two possibilities to this message 1) An alarm has occured. 2) A previously occured alarm has been cleared. power shelf circuit breaker alarm, there might be an internal wiring failure. The power shelf circuit breaker trip wire might be touching the chassis or ground. Or circuit breaker on/off triggered.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-3-SCRIPT_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An error occurred during netio script processing. Please check the error message for more details.), (Recommended Action: Check if the script file exists and is in correct format. If the message recurs, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-UNEXPECTED_EVENT ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node received an unexpected/illegal pulse while running in specified state. Node should not undergo inappropriate action or state change on receiving such unexpected pulse.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-UART_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in UART READ/WRITE access to NPU memory. Exact Cause of the error will be mentioned in the message displayed. This error causes Linux/Application image download and launch to fail.), (Recommended Action: Do cold reboot of Services PLIM MSC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-IM_CB_NAME_TRUNC ### Response: (Severity: 4), (Category: ROUTING), (Description: The length of the context string used to register for Interface Manager callbacks exceeded internal limits and was truncated. If truncation results in registration contexts no longer being unique, this could cause problems with event registrations.), (Recommended Action: This should not happen. The condition represents an internal error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-6-CSF_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: A new CSF packet was received by a local MEP. This message appears because the service to which the local MEP belongs has CSF logging configured.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_ALLOC-7-ERR_CHKPT_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: The FGID Allocator was unable to initialize the checkpoint library. The fgid_allocator process may need restarting, if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-NODE_REBOOT_TIMEOUT_RESET ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the card is being reset because of timeout waiting for the indicated node to perform software reboot. This failure recovery action happens after shelf manager has received notification from the node about its intent to reboot, the failure to self reboot triggered the reset action on the card.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-7-OPERATION_DEBUG ### Response: (Severity: 7), (Category: PLATFORM), (Description: This is a programmed diagnostic debug message.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-IDB_STATE_MONITOR_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_REDDRV-7-MESSAGE_SEND_FAILURE ### Response: (Severity: 7), (Category: PLATFORM), (Description: Sending message got failed. Please check the error.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTH_SRV-3-ERR_3_PARAM ### Response: (Severity: 3), (Category: SECURITY), (Description: auth srv exp error message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-EVM_MSG_ATTACH ### Response: (Severity: 3), (Category: HA), (Description: An internal error was detected when attaching a handler for an Event Manager synchronous message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-SYSTEM_COLD_START ### Response: (Severity: 6), (Category: PLATFORM), (Description: The system is recovering either from a cold restart situation or a state where no valid shelf controller cards were available.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install activate commit command in IOS XR? ### Response: The 'install activate commit' command is a combination of 'install activate' and 'install commit'. It activates the specified packages and commits them as the persistent set in a single step. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-2-DEV_SFP_OPTICS_PORT_UNSUP ### Response: (Severity: 2), (Category: PLATFORM), (Description: A SFP Module not supported for the port error was detected during SFP initialization. A SFP Module not supported for the port error is reported when Optics is not supported on the port. The SFP is the pluggable optics on the line cards. SFP initialization may happen when linecard boots up, SFP OIR and line card process restart. Traffic will not be impacted by this error.), (Recommended Action: Check the 'show controller internal' to see whether the SFP Module is supported for the port. If there are no port unsupported alarm then replace the SFP with a working one (if any) to isolate bad optics. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the command 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_OPTICS_SW_HW_INCOMPATIBLE ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMDR-5-NSF_STOP ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_BAD_ALIGN_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_BAD_ALIGN interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-PCIE_RESP_FIFO_MBE ### Response: (Severity: 0), (Category: PLATFORM), (Description: PCIe response FIFO multiple bits error.), (Recommended Action: Reset the board) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-4-IFIB_FAILED ### Response: (Severity: 4), (Category: OS), (Description: Failure encountered in IFIB lookup.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_13_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPL-3-PAK_CSUM_MISMATCH_NG ### Response: (Severity: 3), (Category: OS), (Description: A checksum mismatch was detected for a packet by NAL), (Recommended Action: The clients of NAL will attempt to recover from this situation by retransmitting the packets. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise, take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-3-MODULE_NOT_SUPPORTED ### Response: (Severity: 3), (Category: L2), (Description: The optics module is not supported in the port it was inserted in . The user will need to remove the optics module from the current port .), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-NON_RELOAD_PARALLEL_LR ### Response: (Severity: 7), (Category: INSTALL), (Description: The restart information in the PIE file is invalid. PIEs that use the 'parallel-lr' install method must use a restart type of 'reload'.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the main components of RPL on IOS-XR? ### Response: The main components of RPL on IOS-XR are\n- Policies - Contain a series of statements to evaluate routes and apply actions\n- Sets - Groups of elements like prefixes, AS paths, communities that can be referenced in policies\n- AS path sets - Define AS path filters\n- Community sets - Define community filters\n- Prefix sets - Define prefix filters\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-7-VERBOSE ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-4-HW_MOD_PROF_ACL_FRAG_NOT_SUPP ### Response: (Severity: 4), (Category: FABRIC), (Description: This message will typically occur when the fragment filter is specified for a linecard that does not support it or when native mode is not enabled.), (Recommended Action: Remove the fragment filter from the IPV6 User Defined Key for this linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MOFRR_FLOW-3-WD_OOR_GREEN ### Response: (Severity: 3), (Category: ROUTING), (Description: By removing the over-configured MoFRR routes, the total number of MoFRR enabled flows is being reduced. When the total number is first time reduced to exactly 75% of maximum supported (1024) MoFRR routes of current release, i.e., 768 routes, this message will be printed on the console and only once.), (Recommended Action: Use show mfib hardware route summary location to check currently total number of MoFRR routes configured in the platform. Then User can configure more MoFRR routes till the Maximum supported MoFRR routes: (1024 for Trident LC, and 2048 for Typhoon LC) has been reached.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_SHIM-7-DRV_ERR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Error condition from switch driver which may affect spanning tree operation on control ethernet. Normally spanning tree can tolerate a few of these errors as long as the driver comes back to a good state. Large number of these messages can indicate bad health of control-ethernet.), (Recommended Action: Check if the switch driver process 'bcm_process' is up and running. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNLIB-3-INTERNAL_ERROR ### Response: (Severity: 3), (Category: SNMP), (Description: This is an internal software error in snlib test.), (Recommended Action: 'Delete and add snmp config ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMACTRLR-3-ERROR ### Response: (Severity: 3), (Category: L2), (Description: A general failure occured while executing the function in question. The message contains info about the location and cause of the failure and possibly anticipated actions/effects.), (Recommended Action: Verify continued correct operation of IMACTRLR.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KENSHO_GL-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Informational Topaz LC Kensho-GL CPU Subsystem DLL message.), (Recommended Action: Nothing. Reporting normal progress of Topaz LC Kensho-GL CPU Subsystem DLL.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SATORI-6-SETTIME_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: It is an informational message indicating that set time has failed, this may be a program level issue), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of BGP communities? ### Response: BGP communities provide a way of grouping destinations into communities and applying routing decisions based on the community. Each community is represented by a 32-bit value, with the format AS:NN. Well-known communities include no-export, no-advertise, internet, and local-as. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-4-UNKNOWN_SHELF_ID ### Response: (Severity: 4), (Category: PLATFORM), (Description: The value read from the power shelf backplane does not match any of the known shelf ID values. Please check the EEPROM programming.), (Recommended Action: Please check the EEPROM programming of the power-shelf backplane. 'show diag power-supply eeprom-info' in admin mode gives a raw dump of the EEPROM data. Refer EDCS-137763 to interpret the data to check if the shelf ID is programmed correctly or not. If the shelf ID is incorrect, the unit will have to be RMA'd to reprogram the EEPROM correctly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_MTU_REDUCED ### Response: (Severity: 4), (Category: ROUTING), (Description: The IS-IS MTU was adjusted to accommodate the fabric MTU of the system. This new MTU may be smaller than the actual MTU allowable by the physical interface.), (Recommended Action: Check any MTU configuration for the interface to ensure that this is not a configuration error. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV6_EA-3-PARAM_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A parameter inconsistency has been detected in the IPv6 Forwarding Information Base.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-DLL_LOAD ### Response: (Severity: 6), (Category: FABRIC), (Description: Fabric driver loaded for the SEA asics.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_AIS_DEMC ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_REDDRV-3-ERR_REGISTRATION ### Response: (Severity: 3), (Category: PLATFORM), (Description: Message send got failed it might be an LWM issue. Please refer the errno in the message for more detail.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-6-INFO_RID_SES_THRESHOLD_NOT_EXCD ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions on a particular Remote ID is no longer exceeding the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-3-ERROR_NO_MEMORY ### Response: (Severity: 3), (Category: SECURITY), (Description: A failure at an attempt to allocate memory was detected.), (Recommended Action: 'This indicates low memory condition, please try after freeing up some resources.' 'If this message recurs, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-READ_FILE ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the Package infrastructure is behaving incorrectly. A file required for carrying out the current request or operation could not be read, so processing of the operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-COMM_DECODE_RDINFO ### Response: (Severity: 3), (Category: ROUTING), (Description: Standby BGP received invalid Route Distinguisher information from Active BGP. *SUPPORT*), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_CFGMGR_REMOVE_DELETES ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_EDM-3-SYSDB_EDM_LIST_ADD_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The attempt to add an item to an external data manager list has failed.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_TRAFFIC_ALERT-2-ALM_CRIT ### Response: (Severity: 2), (Category: SERVICES), (Description: The monitored flow has traffic issues as indicated by the react trigger. The problem is introduced either at some upstream router or even at the traffic source itself. Alternatively, a configuration mismatch between the traffic source and this router (for the flow data rates etc) can cause this error.), (Recommended Action: Check to see if traffic source is indeed sending traffic. Check that the traffic characteristics defined at the source match that on the monitoring router. Trace the traffic flow upstream to the source and verify flow-mon statistics at each applicable hop. Check for packet drops for the flow at intermediate hops - between source and the monitoring router) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure LDP autoconfiguration? ### Response: To enable LDP autoconfiguration, use the 'auto-config' command under the MPLS LDP configuration. RP/0/RSP0/CPU0:router(config)#mpls ldp RP/0/RSP0/CPU0:router(config-ldp)#auto-config <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NRS_LIB-1-REALLOC_ERROR ### Response: (Severity: 1), (Category: OS), (Description: Nrssvr is unable to allocate more space to expand it DB for addtional registrations. This is mostly due to memory fragmentation.), (Recommended Action: Try process restart of nrssvr process since that may free up memory & allow for contiguous allocation in nrs Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-0-ASIC_ERROR_BOARD_RELOAD ### Response: (Severity: 0), (Category: PLATFORM), (Description: Mulitple reset occurred, need to reload board), (Recommended Action: Due to too many reset, board has been reloaded to recover *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-PROC_START_JID ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DAPS-6-UTIL_LOW ### Response: (Severity: 6), (Category: IP), (Description: Utilization dropped below low threshold across all pools. It shows that the existing pools are not utilized well at this point of time. If the utilization is always less than low threshold, pool size can be reduced. Pool utilization can be monitored using the command 'show pool ipv4/ipv6'.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLDR-7-INFO ### Response: (Severity: 7), (Category: PLATFORM), (Description: XRv sysldr information message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-XFER_CORE ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-LABEL_INCONSISTENT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-CRITICAL_PORT_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process detected a failure on a switch port that is critical for control ethernet connectivity. All attempts to recover from the failure by re-initializing the port were unsuccessful, so ESD will reset the switch, then exit so that it will be restarted by the process manager.), (Recommended Action: If this problem does not recur, no intervention is required to recover. To determine why this problem occurred, or if the problem occurs multiple times, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet', and 'show controllers switch trace' commands. Also collect the OS kernel logs. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-CONFIG_DOWNLOAD_SUCCESS ### Response: (Severity: 6), (Category: SERVICES), (Description: 'Download of the config file to the Running config is Successful'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-3-NO_PLATFORM_DATA_FILE ### Response: (Severity: 3), (Category: OS), (Description: The platform data file doesn't exist.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-APS_UNLOCK ### Response: (Severity: 3), (Category: OS), (Description: APS MUTEX LOCK. It is applicable for Debugging of Mutex implementation for APS.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO_API-3-CONN_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'CTRLIO Connection establish failed.'), (Recommended Action: 'ISSU manager will retry operation.' 'If the issue persists ' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_PLIM_SB-3-FPD_IMG_DNLD_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The FPD image download operation for the indicated device has failed. The cause of the error is also indicated in the message.), (Recommended Action: Retry the image update operation and if it fails again, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_33 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: These are unexpected errors), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-PARITY_ERROR ### Response: (Severity: 4), (Category: OS), (Description: Core dump is aborted if the cause for the crash is hardware specific error.), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_TDM-7-NOT_INDEXED ### Response: (Severity: 7), (Category: HA), (Description: Errors (most likely lack of memory) prevent CDM from creating an index structure associated with an indexed table. This condition does not affect the functionality at all, only the performance will suffer.), (Recommended Action: The CDM software will periodically try again to set up the index structure. So, in general no action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ILITE-3-CONFIG_PARAM_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The parameter passed is NULL and call to function getting configuration will fail. This may be a program level error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'install prepare' command in Cisco IOS XR? ### Response: The 'install prepare' command in Cisco IOS XR is used to pre-download software packages to the router and prepare them for activation, allowing for a smoother upgrade process. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_NTP_LIB-7-EXIT_MESSAGE_INFO ### Response: (Severity: 7), (Category: IP), (Description: NTP process went through re-initialization following a specific condition. It can safely be ignored.), (Recommended Action: None required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBCORE-7-DEBUG ### Response: (Severity: 7), (Category: SNMP), (Description: A Debug message for information.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-INVALID_RANGE ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in FIB engine layer. Typically, this is a boundary error. The message string indicates the reason for the failure. Here is a list of possible reasons for this message (not all-inclusive). - Out of supported range. This condition indicates the value is not in allowed range.), (Recommended Action: *Contact Cisco TAC to diagnose the problem*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET-3-PFC_MIB_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An error occured while trying to collect MIB data requested by the SNMP infrastructure. The data for which an error was encountered will not be presented in SNMP 'get' request results.), (Recommended Action: Such errors are not expected, and probably indicate an out-of-resource condition, or an inconsistency in the system state. Wait for any likely transient root problems to subside, and attempt to repeat the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-3-LOW_THRESHOLD_LARGER_THAN_WINDOW ### Response: (Severity: 3), (Category: L2), (Description: For low threshold events to be possible, it is required that the number of possible errors in the configured window is at least as large as the low threshold, which is not currently the case. Note that when window size or threshold is specified in frames or symbols, its length in milliseconds depends on the maximum bandwidth.), (Recommended Action: Consider changing the relevant configuration (i.e. the window and/or low threshold size).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the insthelper process in IOS XR installation? ### Response: The insthelper process assists the instdir process by performing file-related operations on behalf of instdir, such as copying files from the router to the TFTP server or vice versa. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBIPV6PROTO-7-SEND_PACKET_FAIL ### Response: (Severity: 7), (Category: IP), (Description: The transport fails to send a message with packet to the network layer.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_CLEAR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error encountered in RIP clear server.), (Recommended Action: Please retry the command. If the error persists open a case with TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-ERR_EVM_NOTIFY ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cpuctrl Event Manager notify error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-ASSERT ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal consistency check failed. There may be no immediate impact on traffic, but this issue should be addressed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp graceful-restart' command in IOS XR BGP configuration? ### Response: The 'bgp graceful-restart' command is used to enable the BGP Graceful Restart capability. Graceful Restart allows a BGP speaker to continue forwarding traffic while the BGP process is restarting, thus avoiding traffic loss during a planned or unplanned BGP restart. It requires the BGP peers to also support the Graceful Restart capability. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: attestation_agent-6-IMA_KERNEL_DRAIN_FAIL ### Response: (Severity: 6), (Category: MGBL), (Description: Kernel IMA data failed to be freed after adding into disk cache.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-RPKI_ADJCHANGE ### Response: (Severity: 5), (Category: ROUTING), (Description: An RPKI cache has either come up or gone down.), (Recommended Action: This message is informational.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_BMADJ-3-ERR_STR_RT ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM BMADJ, error information), (Recommended Action: Please collect the console log, bundle traces (show bundle trace loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_ABORTBULK ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-2-PCIE_FC_ENUM_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PCIE enumeration error was detected for this Fabric Card. The error prevents this card to do traffic switching thereby making it unusable), (Recommended Action: Please correct the problem by OIR the FC card. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-MIB_INDICES_EXHAUSTED ### Response: (Severity: 4), (Category: L2), (Description: The pool of MIB indices to assign to Frequency Synchronization sources has been exhausted. MIB data from the Frequency Synchronization feature may be inaccurate.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_2_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_2 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-NO_I2C_TOPO_FILE ### Response: (Severity: 3), (Category: DRIVER), (Description: IOFPGA driver was not able to retrieve I2C topology file to perform basic driver initialization. Process will be restarted to attempt to recover from this.), (Recommended Action: Check for missing hardware abstraction layer implementation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-ENTITLEMENT_RENEW_FAILED ### Response: (Severity: 3), (Category: LICENSE), (Description: The device has failed to communicate with Cisco to renew the entitlement authorization.), (Recommended Action: Please check the smart agent syslog messages for further information. Also, please check Smart Call Home settings and network connectivity to cisco.com.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-SUSPENSION_START ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-ERR_INVALID_L2ACL_CONF ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Only 2 ACE's allowed, 1st ACE has to be Deny on ISIS DMAC, 2nd ACE has to permit any any, rest all the config is invalid.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR handle packet filtering? ### Response: Cisco IOS XR handles packet filtering through the use of ACLs and Unicast Reverse Path Forwarding (uRPF), providing mechanisms to control the flow of traffic and prevent spoofing attacks. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_IPV6_EA-3-ERR_MEM_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Typically, this is an error where the memory allocation / access fails. Here is a list of possible reasons for this message (not all-inclusive). 1) Memory exhaustion due to overall system load 2) Shared memory access failure 3) Memory leaks leading to resource exhaustion), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show cef ipv6 location <> show cef ipv6 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_XRV_SCH_LIB-3-EVM_ATTACH_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Smart Call Home failed to attach an event handler function to EVM.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ASIC-3-HW_ERR ### Response: (Severity: 3), (Category: L2), (Description: Plim Asic errors. Typically these indicate errors detected by the ASIC. Too many of these errors might indicate problem with the board, and can trigger a reload of the LC.), (Recommended Action: Check whether process 'plaspa_server' is up and running. Check if the linecard reported any other errors and/or traffic loss was observed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-ROOT_USERDB_INIT_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: Accounting daemon failed to create/remove the root user database on the disk0. This will affect authentication to ksh since it refers to this database.), (Recommended Action: As a workaround an admin could create this directory in disk0 himself. This should get around the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-SYSDB_BIND_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Sysdb bind error. OBFL will fail to function as critical config data is kept in sysdb.), (Recommended Action: collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging 5. show tech-support sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_FPD-2-GOLDEN_IMAGE_BOOT ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message indicates that the FPD booted from golden image due to issue with primary image.), (Recommended Action: Upgrade the primary and take action based on the status after upgrade) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_SYSDB_EDM_FNS_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_IFH_UNBIND ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_UV-3-ERR_VRFN_FNS_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: The ospf_uv process was unable to initialize SysDB callbacks.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAP-3-WHITEBOX_INVALID_B2B_DETECTED ### Response: (Severity: 3), (Category: INFRA), (Description: An invalid Back-to-Back connection has been detected.), (Recommended Action: Determine if the event was due to a fault. If so, the root cause need wiring/connectivity check.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-SKIP_NRV_RECOVERY_NOTICE ### Response: (Severity: 5), (Category: ROUTING), (Description: User has tried to do switchover for this tunnel to recover from \ non-revertive path. However, this tunnel currently has no pending \ LSP that's ready to take traffic. The requested switchover has \ been abandoned and the tunnel will continue to use the current \ in-use path.), (Recommended Action: Ensure that the pending LSP is fully established before attempting \ to recover a non-revertive tunnel.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ERRDIS-4-AUTO_RECOVERY_RETRY_DISABLED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Auto-recovery failed on an interface and will not be retried due to the auto-recovery configuration being deleted.), (Recommended Action: This is a warning message and no action is required. An interface that is no longer configured for auto-recovery was not auto-recovered at the final attempt because the error-disable condition still holds. The interface will remain in error-disable state and auto-recovery attempts will now cease. Future attempts to clear error-disable state should be done manually or auto-recovery should be reconfigured.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-BF_OVR_ERR_FIA01 ### Response: (Severity: 3), (Category: PLATFORM), (Description: FIA01 burst FIFO overflow error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C_SERVER-6-GN2412_CHIP_RECOVERED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-6-WAN_SWITCH_FAILED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND-3-ERR_SRG_ATTR_GET ### Response: (Severity: 3), (Category: IP), (Description: Cannot determine whether SRG is enabled or not on the interfaces), (Recommended Action: Restart IPv6 ND) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_SYSDB_EDM_FNS_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-INTR_DISABLED_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: NP experiencing storm of interrupts. Disabling interrupt to avoid CPU HOG. Will be activated only after a line card reset), (Recommended Action: Identify the cause of interrupt storm) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-LINK_ERROR ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. Topology between FSDB and hardware is not matched. This issue may be fabric plane config issue or Fabric mis-cabling between S13 and S2 cards. 2. For Link in error state : This link is in error state due to errors on the link.), (Recommended Action: Reset the link. In most cases after reset of the link it should come UP fine. Collect all the event logs and the output of the following commands executed from the CLI of the active RP: 1. 'show running controller fabric plane' 2. show controller sfe link-info rx 0 127 topo instance all loc 3. Collect all traces:'show controller sfe trace all location ' 4. Collect DSC and eyescan data for this link and also for the far end link Steps to collect DSC and eyescan : 1. Disable link_mon thread 2. Disable Stats thread 3. Disable rx_los for the link 4. Collect DSC and eyescan If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XFP-2-LOW_LASER_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected an XFP laser bias less than or equal to the low laser bias alarm threshold. The XFP is the pluggable optics on the line cards. The laser bias threshold values are read from the XFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-SP_INVAL ### Response: (Severity: 4), (Category: OS), (Description: Core dump failed because the stack pointer is corrupted.), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-6-BOOT_IMAGE_COMPLETE ### Response: (Severity: 6), (Category: INFRA), (Description: ZTP has successfully performed pre-provisioning actions that include booting of an image.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_LIB-3-FOLLOW_STANDBY_MISMATCH ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Conflicting 'follow standby' instructions were supplied to the Adjacency Manager for an interface. 'Follow standby' is specified for an interface by a Service State Controller if it believes that traffic should be directed towards the standby, rather than active, service instance. This message indicates that the active and standby Service State Controllers gave conflicting information about where traffic to be directed to. This indicates an inconsistency between the system state as viewed by the Service State Controllers that are responsible for the service to which the interface belongs. Restarting those processes may help, after allowing any other problems that could lead to inconsistencies being resolved. No adjacencies will be installed for the interface, and all traffic to it will be dropped.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_BRIDGE_EVM ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric Bridge driver Event Manager create error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PDMA_SPP-3-CHANNEL_NOT_PROPER ### Response: (Severity: 3), (Category: PLATFORM), (Description: channel_connect_id is not proper for SPP PDMA. %s- Function Name. %d- Line number.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISK_DRIVER-3-FAILED_TO_CREATE_EVM ### Response: (Severity: 3), (Category: PLATFORM), (Description: ATA device might report these errors when it unable to create ATA_EVM.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERR_INFO_NOT_SUPP ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, feature not supported), (Recommended Action: This error is expected since the feature or the scale being configured is not supported. If you believe there is still some problem, please collect FIB platform trace (show cef platform trace all all loc <>), 'show install active', 'show version', 'show platform' and 'show console logging' output. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTP7 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-TIMER ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: The packet subsystem encountered an error while operating/handling a timer.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-3-FREE_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failure occured while releasing shim window memory due to one of the following reasons: 1. Invalid arguments passed to the function 2. Error occured while performing memory related operations), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-MBE_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: A multi bit error was detected in RAM of the IM in given slot. IM will be soft reloaded for recovery), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-6-FABRIC_BANDWIDTH_HIGH_THRESHOLD ### Response: (Severity: 6), (Category: FABRIC), (Description: When the available fabric BW goes above the required BW that corresponds to the high threshold, then the front panel ports of the LC goes back to unshut.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_ASR9K_PFI_LIB-3-SET_GLOBALS_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Platform PFI was unable to set globals bacause of some shared memory issues.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-FD_INIT ### Response: (Severity: 3), (Category: HA), (Description: An internal error was detected when initializing the fault detector.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPD-4-NO_ADDR_ASSIGN ### Response: (Severity: 4), (Category: IP), (Description: The error occurs when Server is in process of sending ACK to client and while doing this tries to get IntF address/Client State/VRF etc. where it encounters failure. Thus leading to failure of Address assignment to client.), (Recommended Action: Retry) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-3-SHMWIN_ERROR ### Response: (Severity: 3), (Category: QOS), (Description: The DPA QoS EA module encountered a shared memory error. The message will provide further details on the error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_IR1_INTR_SHORTKT_DROP_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_IR1_INTR_SHORTKT_DROP_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of WDSYSMON in process monitoring? ### Response: WDSYSMON (Watchdog System Monitor) is a process monitoring mechanism in Cisco IOS XR that detects process failures and initiates corrective actions. It monitors critical processes and can restart or failover to a standby component if a process becomes unresponsive or crashes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-RECOVER_FAILED ### Response: (Severity: 3), (Category: MEDIA), (Description: The NVRAM device corruption recovery attempt has failed.), (Recommended Action: Restart nvram server process. If this doesn't help Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_4_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-DDR_LOSS_OF_SYNC_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Loss of sync on DDR interface on bridge instance-3.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the adjacency stagger command in IS-IS? ### Response: The adjacency stagger command is used to stagger the formation of IS-IS adjacencies after a router reload or IS-IS process restart. This can help prevent all adjacencies from coming up simultaneously, which can cause a temporary spike in CPU utilization. By staggering the adjacencies, the CPU load is spread out over a longer period, which can improve system stability during a restart. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-TBLATTR_VERSION ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal error was encountered.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-3-OOR_OPER_FAIL ### Response: (Severity: 3), (Category: L2), (Description: A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location show cef trace location show cef platform services trace ipv4 all reverse location show cef platform services trace common all reverse loc show cef location show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-RX_ALARM_LOS_SYNC_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: For T1 mode LOS is declared (as detected by BITS receiver) when no pulses are detected in a window of 192 consecutive pulse intervals. In E1 and 2048kHz modes LOS is declared when no pulses are detected in a window of 255 consecutive pulse intervals. For UTI mode, LOS is detected by hardware as per J.211 specifications.), (Recommended Action: 1) Ensure cable connection between the configured interface port and external equipment. 2) Check the cable integrity and cable connectors. The receive pair should be on pins 1,2 on the RJ-45 jack.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP_NSR-5-DISABLED ### Response: (Severity: 5), (Category: IP), (Description: TCP stack detected NSR functionality impairment and has disabled NSR for the connection.), (Recommended Action: Understand why NSR failed and take the necessary steps such as collecting core file, traces etc. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_XBAR-2-ERR_ACCESS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Crossbar driver detected an issue with ASIC read and write access. A persistent ASIC access error indicates an issue with the hardware.), (Recommended Action: Please power cycle the card using command: 'hw-module loc <> reload' and check if this error persists. If the error persists, then the card needs to be replaced.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-3-PCIE_CORE_ERROR_OVERRUN_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_HFR-3-EDM_OPER_SETUP ### Response: (Severity: 3), (Category: ROUTING), (Description: MFWD-HFR library encountered error while initializing the edm oper handlers), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-CORE_PAGE_LOST ### Response: (Severity: 4), (Category: OS), (Description: Not enough free memory to continue COPY option core dump, which allocate local memory for each meory segent.), (Recommended Action: Ensure that enough free space is present. If not, remove COPY option.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRID_SVR-7-ERR_INIT ### Response: (Severity: 7), (Category: PLATFORM), (Description: Initialization of lrid server process has failed due to one of the following reasons: 1) Failed to initialize LRID Server.), (Recommended Action: No action is required. Process will be restarted. If not recovered, it's a fatal condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-FPGA_SPURIOUS_INTERRUPT ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-QDR_MEM_ECC_FAIL_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: QDR memory ECC failure on bridge instance-2.), (Recommended Action: Please reload the board using the command 'reload location <>'. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REBOOT_LIB-6-SDRNM_INVOKED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-3-EPM_SWITCH_LINK_FAULT_NORELOAD ### Response: (Severity: 3), (Category: PLATFORM), (Description: a critical link of EPM switch device is down), (Recommended Action: The board is not reloaded. At this stage please collect the output of (admin)'show tech support control ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_10_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCMD-3-STR_SIZE ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error due to request for string size larger than supported.), (Recommended Action: Report to Technical Assistance. This error could result in some part of the RCMD report generated being incorrect or incomplete.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'l2vpn switchover' command in Cisco IOS XR? ### Response: The 'l2vpn switchover' command is used to manually switch the traffic from the primary pseudowire to the backup pseudowire in a VPWS service with pseudowire redundancy configured. This command is useful for testing the redundancy setup and for performing planned maintenance on the primary pseudowire or PE router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO-3-ERR_CCI_CREATE_Q ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cannot create pdma queue required. Likely a asic driver does not come up properly %d - 0 ingressq; 1 egressq; 2 fabricq 0; 3 fabricq 1 %d - number of seconds elapsed), (Recommended Action: Investigate if driver processes(ingressq, egressq or fabricq) initialized properly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-EVENT_ATTACH ### Response: (Severity: 3), (Category: MGBL), (Description: The call to event_*_attach() failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CERR_LIB-7-CORRUPT ### Response: (Severity: 7), (Category: OS), (Description: The infrastructure library detected a corrupt data structure while performing internal checks.), (Recommended Action: Run diagnostics to determine if this is a result of a hardware problem. If the problem reoccurs, a memory dump should be taken to assist TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPP-3-DEBUG_INIT_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Unexpected error is encountered while initializing the debug event.), (Recommended Action: If the message recurs, issue the command 'show mgmt-plane trace client both' to gather data and provide the gathered information and the exact error message as it appears, to the Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HAL_COMM_DBG-3-ERR_INFO_VERBOSE ### Response: (Severity: 3), (Category: PLATFORM), (Description: An internal error occurred in FIB engine layer for collecting traces. The message string indicates the reason for the failure. This message also provides an error code. Additionally, it provides a more verbose information of the error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-4-FILE_OPEN ### Response: (Severity: 4), (Category: PLATFORM), (Description: Failed to open log file for redundancy driver.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_IPV4_EA-3-CRITICAL ### Response: (Severity: 3), (Category: PLATFORM), (Description: DNX IPV4-EA, Critical error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-4-WARM_RESET_FAILED ### Response: (Severity: 4), (Category: L2), (Description: This is an error message in the PSE Driver to indicate that it failed to perform warm reset of specified pse instance due to the specified reason.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-5-TIMEOUT_CANCELLED ### Response: (Severity: 5), (Category: HA), (Description: An event manager has resumed sending heartbeats. This happens when a condition that caused the hang is cleared.), (Recommended Action: The debugging information collected when the event manager stopped sending heartbeats should be examined and provided to technical support for analysis.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBIMGR-3-NODEID_EXTRACT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Either an invalid location is being queried, or the infrastructure is behaving incorrectly. The MBI operation in progress may not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-API_FAIL ### Response: (Severity: 3), (Category: MGBL), (Description: 'An API failed due to the mentioned error'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_EVM_CONN_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-4-INVALID_NODEID_RETURNED ### Response: (Severity: 4), (Category: INSTALL), (Description: Install director detected that the passed in node was incorrect.), (Recommended Action: Collect insthelper traces from this reported nodes using 'show install trace insthelper'. This error will be recovered automatically. No user action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-BAD_PATH ### Response: (Severity: 6), (Category: OS), (Description: Please configure a valid path for any exception path.), (Recommended Action: Try to configure other paths.Do not configure boot device as exception path.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-ISSU_ON_ABORT_NO_RELOAD_INSTDIR ### Response: (Severity: 6), (Category: INSTALL), (Description: When initiating the ISSU operation, the user specified the on-abort no-reload option. This message indicates that on abort, no recovery or clean up will be performed. The user has indicated 'on-abort no-reload' hence, no recovery will be performed as part of abort. This is a non-error condition.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_4 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-6-BOOT_MODE ### Response: (Severity: 6), (Category: PLATFORM), (Description: The boot mode is detected and printed by the system during startup. Cold boot signifies system booting up fresh, HW ASICs getting reset. Warm boot signifies system booting up while ASIC continues to forward traffic.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PVSTAG-4-MALFORMED_PACKET ### Response: (Severity: 4), (Category: L2), (Description: A packet that was unexpected or malformed was received. Most commonly this is the result of a misconfiguration, causing for example, PVRST packets to be received on a port that is configured with PVST-AG.), (Recommended Action: Verify the configuration. If the configuration is correct, investigate the problem on the sending host, or by using a packet sniffer to verify the packets are well-formed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-3-BAG_ENCODE_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to encode a bag.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_IN_MEM_CORR_ECC_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast input memory correctable ECC error on link 2), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-MFI_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured while processing something from or to LSD. This is a fatal software error and the IS-IS process will abort or become inconsistent), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-MEDIAERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Media table lookup failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-DUP_RTRID ### Response: (Severity: 3), (Category: ROUTING), (Description: OSPFv3 received hello packet from a neighbor which has the same router ID as this routing process. A full adjacency cannot be established.), (Recommended Action: OSPFv3 router ID must be unique. Change the router ID.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XRV9K_INTF_INJ_CAP_DLL-3-LTRACE_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The ltrace file could not be created.), (Recommended Action: Please contact TAC Support Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_BDI_DEMD ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-NPU_1_FC_DIP2_ERR_3 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress flow control DIP2 parity error on NPU-1 interface on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_INSERT_GLOBAL ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA tried to insert an interface into the global session tree which was already there. The error is probably caused by a programming error.), (Recommended Action: PPPoE MA should recover by itself.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-4-ROMMONA_DOWN_REV ### Response: (Severity: 4), (Category: PLATFORM), (Description: For displaying down-rev notification.), (Recommended Action: tech support should be contacted for upgrade instructions) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_6_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-2-ASIC_ERROR_CIH_INIT_THRESHOLD_EXCEED_IGNORED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Ignoring CIH persistent card threshold exceed condition due to user recovery file), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_LOSS_OF_LOCK ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_EVM_TIMER_ATTACH ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-4-MCLAG_CONFIG_CONFLICT ### Response: (Severity: 4), (Category: L2), (Description: A configuration conflict has been detected: Interface %s already used by ICCP-SM feature. MCLAG will not work until the conflict is resolved.), (Recommended Action: For MCLAG to work for this interface, one must delete relevant configurations for both ICCP-SM and MCLAG. Then re-configure MCLAG.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-ADJACENCY_UPD_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'CTRLIO Adjacency update failed. ' 'Updating shared memory entries failed.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PM_SHOW-7-USAGE ### Response: (Severity: 7), (Category: PLATFORM), (Description: Startup option supplied to HFR_PM_SHOW is not valid.), (Recommended Action: Please re-enter the correct option as described in the usage message 'Usage: hfr_pm_qos_gran_show -G [-N ]' Example: show hw-module qos shape granularity location 0/2/CPU0, or run hfr_pm_qos_gran_show -G 33) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERG-5-SYNC_DONE ### Response: (Severity: 5), (Category: INFRA), (Description: The requested sync of sessions has been completed. This is in response to CLI command and any inconsistencies in the state between the peers would have got resolved.), (Recommended Action: None required since this is in response to an administrative action that caused this synchronization of sessions. Session status may be checked on the router to verify consistency, if desired.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-7-FAILMSG ### Response: (Severity: 7), (Category: INSTALL), (Description: Interpret the error string.), (Recommended Action: Check for disk corruption using 'fsck' disk check CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-CRRS_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a parity error), (Recommended Action: Please correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_TCAM_ODS_INSERT ### Response: (Severity: 3), (Category: OS), (Description: TCAM ods insert error.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_THOR_L2FIB-3-CERR_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the cerrno module in the platform L2FIB component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SE_INFRA_MGR-3-SYSDB_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: The message indicates the failure in registering the user service instance in the database.), (Recommended Action: Please provide the following logs: Copy the error message exactly as it appears on the console or in the system log. Issue the cmd command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the cmd output, call your Cisco technical support representative and provide the representative with the gathered information. - Show logging - show services secontroller trace reverse location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGPTE_LIB-3-ERR_SYSDB_UNREG_NOTIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurrred when accessing the system database), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The process must be restarted before it can function correctly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-IMPROPER_PREFIX_MASK_LEN ### Response: (Severity: 3), (Category: ROUTING), (Description: A client sent a batch to RIB containing an invalid op code.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDLD-2-DISABLE_PORT ### Response: (Severity: 2), (Category: L2), (Description: UDLD protocol detects if a link is uni-directional and disables the port. Uni-directional links can cause problems in ethernet networks and should be fixed.), (Recommended Action: Check the link on which the error happenned. Try replacing/reconnecting the GBIC/SFP/cable at either end of the link. Re-enable the port on the RP and see if the port comes up. If the problem still exists the port will be disabled again with this message. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_FPOE_DB_UCORR_ECC_ERROR_LNK1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast FPOE uncorrectable ECC error on link 1), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-CLINFO_SAVE_DATUM ### Response: (Severity: 7), (Category: HA), (Description: An internal error was detected when trying to save an application datum associated with the given channel handler.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-SPA_OVERTEMP_MAJOR ### Response: (Severity: 4), (Category: PLATFORM), (Description: SPA temperature is risen above or fallen below major threshold.), (Recommended Action: Verify the failure, use show env to help. If the failure does not alleviate, call your technical support representative for repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-FABRIC_PRGM_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Failed programming batch in fabric from PD.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-4-MASA_AUTH_FAIL ### Response: (Severity: 4), (Category: SERVICES), (Description: 'The MASA - manufacturer authorised signing authority ' 'has not authorised this device in its network'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-SHUTDOWN_ON_ENVMON_ALARM ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is being brought down to IN_RESET state due to occurence of multiple critical environmental alarms on the node related to power/voltage/temperature.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_EA-4-ERR_RWMGR_IF ### Response: (Severity: 4), (Category: L2), (Description: PPP EA encountered an error communicating with Rewrite Manager. The error message describes what operation has failed and why it failed. The most likely reason for this is a temporary connection problem with the Rewrite Manager Server process, but the error could also be caused by low memory resource or programming error.), (Recommended Action: In many cases, PPP EA will recover by itself. If it does not then restarting the process may help. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-ISSU_OP_ABORT_FABRIC_RELOADED ### Response: (Severity: 2), (Category: INSTALL), (Description: During ISSU operation, the specified fabric node was reloaded unexpectedly thus the current ISSU operation is aborted.), (Recommended Action: Please ensure that the fabric node is not reloaded during ISSU and retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-7-THREAD_CREATE ### Response: (Severity: 7), (Category: OS), (Description: The pthread_create function reported an error.), (Recommended Action: Collect the output of show tech-support, show processes , show memory, and show watchdog memory-state from the location the error message comes from. If the error message doesn't persist, it can be ignored. If the error message persists,call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE4_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE4_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-7-ADDR_POOL_REUSE ### Response: (Severity: 7), (Category: SERVICES), (Description: This address pool that is being configured is also used by different inside vrf of different cgn instance.It is supported by CGN.So you can ignore this message.Its just information message.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_ACL-4-IPACCESSRLIMIT ### Response: (Severity: 4), (Category: ACL), (Description: The ACL library has requested the operating system to grant additional heap memory. The request has failed and the error indicating the reason has been given), (Recommended Action: Collect the requested show tech-support info and forward it to development engineering team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR optimal option? ### Response: The MPLS TE FRR optimal option allows the best available backup path to be used for FRR by considering the tunnel's constraints and attributes. It tries to find a backup path that is identical to the primary path with respect to bandwidth, affinities, priority, and so on. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-PCIE_BAD_READ_ADDR ### Response: (Severity: 2), (Category: PLATFORM), (Description: CIB PCIe bad read address), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-PROC_CRASH_JID ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-2-SESSION_COUNT ### Response: (Severity: 2), (Category: SECURITY), (Description: Attempted to decrement session count which is already zero after a SSH session has been terminated.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPP-3-EVENT_MANAGER_FAILURE ### Response: (Severity: 3), (Category: SECURITY), (Description: Event manager could fail if system resources (eg: memory) is not sufficiently available for use.), (Recommended Action: If it is related to process-level resources, restarting the concerned process might solve the issue. If the message recurs, issue the command 'show mgmt-plane trace client both' to gather data and provide the gathered information and the exact error message as it appears, to the Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-2-TEMP_OVER_LIMIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Crossbar driver detected that the current ASIC temperature is over threshold.), (Recommended Action: Please check card inlet and hotspot temperature sensor readings and fan speed using command 'show environment temperatures' and 'show environment fans'. Ensure all empty slots are populated with latest filler cards and chassis ambient temperature is within documented limits. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRMS-3-IPC_ERR ### Response: (Severity: 3), (Category: L2), (Description: An IPC transport software error occurred. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Restart SRMS process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-ERR_MSG_GET_SCOID ### Response: (Severity: 4), (Category: ROUTING), (Description: OSPF failed to retrieve its local connection ID for a client attached to the specified channel. This is an internal programming error.), (Recommended Action: Restart the OSPF process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-6-OIROUT ### Response: (Severity: 6), (Category: PLATFORM), (Description: Entity specified in the messages is removed from the chassis and inventory manager is updated.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-XFP_LNK_FAULT_ERROR_2 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the XFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. Do XFP OIR. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-FIFO_1_OFLOW_FIA2BR_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: FIFO-1 FIA to bridge instance-0 overflow.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_1_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-3-INIT ### Response: (Severity: 3), (Category: MGBL), (Description: A fatal error was encountered during initialization.), (Recommended Action: If the process does not restart automatically then try manually restarting it. A likely cause for this error is that the system has run out of memory. If this is not an out-of-memory problem and restarting the process does not solve it then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-INSUFFICIENT_PATH_BUFFER ### Response: (Severity: 3), (Category: ROUTING), (Description: During copy path operation, the destination path buffer seems to have insufficient space to copy entire source path (including path info & path TLVs). Due to this the destination path will have incomplete information and may result into functionality issues.), (Recommended Action: Bring the BGP session down for the affected neighbor.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-MVUDRV_INIT_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: Marvell user level device driver initialization failed. This is a fatal fault since ESD would not receive hotplug events thereafter. ESD process will restart after this fatal error.), (Recommended Action: If this problem does not recur, no intervention is required. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-CALIBRATION_DATA_PARSE_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Linecard device calibration data parsing failed. It is applicable for Digi 20x10g and 2x100g Digi cpak cards.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_HFR-3-ERR_QAD_EGRESS_QUEUE_MISSING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to find the qad queue for egress packets. This could causes applications using this qad queue not sending out packet %s - QAD queue name %s - thread name), (Recommended Action: Reload the card. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-ERR_SYSDB_STRING_ENCODE ### Response: (Severity: 3), (Category: MGBL), (Description: 'Sysdb path has string that has special character without sysdb_encode flag'), (Recommended Action: Collect the following details: 1. Command issued 2. show parser trace. 3. console logs. 4. If config is restored from file, then filename/contents. 5.If command failed at startup, show config trace and show config failed startup.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_CPP_LCPM_SHOW-3-SYSDB_IM_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: sip-pm show encountered trouble in sysdb operations, im control server bind or imc interface get operations), (Recommended Action: Please enable 'debug im api errors', 'debug sysdb access ...' and capture the output.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show ospf mpls traffic-eng' command in IOS XR? ### Response: The 'show ospf mpls traffic-eng' command is used to display information about how OSPF is interacting with MPLS TE. It shows the OSPF process ID, the area ID, the router ID, and the MPLS TE router ID. It also shows the MPLS TE link information that OSPF is advertising. This command is useful for verifying the integration between OSPF and MPLS TE. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'l2vpn bridge group' command in IOS XR? ### Response: The 'l2vpn bridge group' command is used to configure a point-to-multipoint Layer 2 VPN (L2VPN) service, also known as Virtual Private LAN Service (VPLS). It creates a virtual bridge domain that connects multiple sites as if they were on the same LAN. The 'bridge group' command defines the VPLS instance and its associated parameters. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOADPATH-7-FILE_CLOSE_FAIL ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the loadpath infrastructure is behaving incorrectly. A file involved in the current request or operation could not be closed. This will not affect the current operation, but subsequent operations may be affected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-ASIC_RESET ### Response: (Severity: 3), (Category: FABRIC), (Description: The asic device failed due to the above mentioned error. The device is being reset to recover from failure), (Recommended Action: Collect all the event logs and the output of the following commands executed from the CLI of the active RP if the asic is continuously reset and recovery does not take place after device reset: 1. 'show processes npu_driver location ' 2. Collect all ltraces: 'show controllers npu trace all location ' 3. dmesg and /var/log/messages from host and XR VM If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_PRM-3-NO_OP_BUFFER ### Response: (Severity: 3), (Category: PLATFORM), (Description: There is no buffer available for the operation request.), (Recommended Action: Please collect output of the following commands: show platform show install active show log show process blocked location <> show process location <> follow process iter 5 delay 2 location <> show controller rm prm client trace info location <> show controller rm prm client trace error location <> show controller rm prm process location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-2-FABRIC_PING_NOT_OK ### Response: (Severity: 2), (Category: PLATFORM), (Description: Need to print the console messagess when the fabric ping to particular node occurs.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-UNKNOWN_FAB_DEST ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric Destination card type is invalid although the plane is available. Traffic is being disabled to this. This might happen if the destination is down or has been removed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-5-CLOCK_INTERFACE_PORT_0_OUTPUT_SQUELCHED ### Response: (Severity: 5), (Category: PLATFORM), (Description: When no external clock source is available, this status propagates to BITS output ports in 2MHz and 6.312MHz modes. When an external source is qualified, this alarm will be cleared.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND-4-WARNING_CACHE_LIMIT_HIT ### Response: (Severity: 4), (Category: IP), (Description: An attempt was made to exceed the configured IPv6 Neighbor Discovery (ND) entry limit for this interface. This condition is reported only once for every 1000 attempts (hits).), (Recommended Action: Configure a larger cache limit on the interface. In interface configuration mode, use the command ipv6 nd cache-limit. To help estimate an appropriate value, use the commands: show ipv6 interface show ipv6 neighbor .) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-CORRUPT_HEAP ### Response: (Severity: 3), (Category: OS), (Description: --), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SEG_HDR_EXT_FIFO_OFLOW_0_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress seg hdr ext fifo overflow on xaui-0 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TOMAHAWK-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Informational Tomahawk RP Kensho-JF CPU Subsystem DLL message.), (Recommended Action: Nothing. Reporting normal progress of Tomahawk RP Kensho-JF CPU Subsystem DLL.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-7-PSOC_UPGRADE_IN_PROGRESS ### Response: (Severity: 7), (Category: PLATFORM), (Description: This is an informational message indicating that PSOC firmware upgrade is in progress on the specified location. The line that is being presently upgraded is mentioned in the message. This line number would be in the specified range, corresponding to the PSOC that is being upgraded.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-PACKET_DECODE_UNEXPECTED_TLV ### Response: (Severity: 4), (Category: L2), (Description: A packet containing an unexpected TLV was received on the given interface. The packet has been processed normally and the unexpected TLV has been ignored. This message indicates that the device from which this packet originated is creating packets which deviate from the expected format of packets of this type according to the IEEE specification (IEEE 802.1ag-2007 or ITU-T Y.1731 02/2008). While the message is harmless, the user may wish to check the standards compliance of the remote device, which is indicated by the provided source MAC address.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_DLL-2-TAKING_NODE_DOWN ### Response: (Severity: 2), (Category: FABRIC), (Description: CCSQ DLL encountered an fatal error mentioned above. The driver triggers MSC node-down to recover from the error.), (Recommended Action: This might be a recovery action from a fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-3-ERR_LIST_CREATE ### Response: (Severity: 3), (Category: L2), (Description: The list here refers to the ifhandle list or the idb list for the bundle or its members. Also, it could be the STATE change list as well for IM. The argument shows up the type of list which was failing to get created.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. This shows a low memory condition on the node. Try to reduce the amount of memory being consumed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBUS-3-HBM_BURN_LANE_REPAIR_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the SBUS Driver to indicate that the burn lane repair operation has failed on the specified HBM memory), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-LTRACE_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: Initialization of trace functionality for config failed. This would affect the debugging of config shell.), (Recommended Action: Retype the command to do config operation again. If the message appears again, copy and save the message. Collect show logging output and any other suspicious error messages on console and inform technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOMAIN_SERVICES-3-OPEN_EVENT_CONN ### Response: (Severity: 3), (Category: IP), (Description: The domain_services process failed to open a event connection. The message would appear during initialization of DNS process (i.e. domain_services) when it is trying to create sysdb connection. Such errors are not expected and should go away with proc restart domain_services), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-WRONG_PIE_LOADER ### Response: (Severity: 7), (Category: INSTALL), (Description: The PIE file was passed to the wrong loader function. The current request or operation will not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_0_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser bias greater than or equal to the high laser bias warning threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-CANT_MKDIR ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the infrastructure is behaving incorrectly. The Package infrastructure could not create a required directory, so processing of the current operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_DRIVER-7-TOO_LONG_DEVICE_NAME ### Response: (Severity: 7), (Category: OS), (Description: Too long device name is specified), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can BGP prefixes be originated using the network statement? ### Response: The network statement is used to advertise a prefix if it exists in the routing table. The mask of the network statement must match the mask in the routing table. The route must be in the routing table before BGP will originate it. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-3-FIELD_DEPEND_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The PMF dependency ordering is incorrect for the groups configured.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-MCAST ### Response: (Severity: 3), (Category: ROUTING), (Description: The above specified multicast operation failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-NO_MEMORY ### Response: (Severity: 3), (Category: OS), (Description: Not enough memory available in the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the top memory users can be identified to be the memory leak source, try process restart the top memory user processes to recover the condition.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APIV-3-SW_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An internal software error has occurred for the specified APIV module), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'send-community-ebgp' and 'send-extended-community-ebgp' commands in IOS XR BGP configuration? ### Response: By default, BGP does not send community or extended community attributes to eBGP neighbors. The 'send-community-ebgp' and 'send-extended-community-ebgp' commands enable sending these attributes to eBGP neighbors. This is necessary when you want to carry community information across AS boundaries, for example, for implementing BGP RTBH filtering. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_5 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-4-FAB_BUILDUP ### Response: (Severity: 4), (Category: OS), (Description: GSP fabric queue buildup indicates underlying transportor hardware issue), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-3-BAD_PUNT_NODE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A NetIO feature DLL has attempted to pass a bad chain node to a NetIO packet punt API. The packet has been dropped.), (Recommended Action: Identify the NetIO DLL that is passing the bad node, and contact the owners Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_EA_VERIFY-6-ERROR ### Response: (Severity: 6), (Category: QOS), (Description: The QoS EA policy verification encountered the specified error. This may happen because the QoS policy is invalid and cannot be applied successfully.), (Recommended Action: Check the output of 'show config failed' and correct the qos policy appropriately.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_ERRORS-3-ERR_ECM_REG ### Response: (Severity: 3), (Category: L2), (Description: ASIC Error library encountered an error while setting up a SYSDB notofication handler with the event connection manager.), (Recommended Action: An error would be reported to the client application which should handle this condition appropriately. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-CHASSIS_IN_MIGRATION_MODE ### Response: (Severity: 4), (Category: DRIVER), (Description: Normally chassis should either be in 1T or 2T fabric mode. Meaning all cards ex: fan trays, fabric cards, LCs should be compatible with the current mode. Migration mode is when one is migrating from either 2T to 1T or vice versa. In this case a mix of Fabric cards (ie 1T FCs and 2T FCs) is allowed while cards are being swapped out. Note that all FCs must be of the same type to exit migration mode. New 2T LC insertions are not allowed during migration (must transition to 2T fabric mode).), (Recommended Action: Complete migration ie swapping out all FCs to either 2T or 1T FCs ASAP. Although 1T can work with a mix of 2T FC and 1T FCs it is not recommended to remain in this mode.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_HFR-4-LTRACE_INIT_FAIL ### Response: (Severity: 4), (Category: FABRIC), (Description: ltrace initialization failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-7-ERR_SYSDB_FD ### Response: (Severity: 7), (Category: SECURITY), (Description: Error encountered while using the System Database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-4-PROTGRP_OOR ### Response: (Severity: 4), (Category: ROUTING), (Description: Adding ECMP failed due to Protection Groups OOR .), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ASIC-3-SW_ERR ### Response: (Severity: 3), (Category: L2), (Description: The operation is failed due to an internal software error. %d - instance. %s - description of the operation. %s - description of the error.), (Recommended Action: Check if the linecard reported any other errors. May need to restart process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-3-SEND_MSG_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This error message indicates message failure from server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-3-EVENT_CONN_ERROR ### Response: (Severity: 3), (Category: TOPOLOGY), (Description: Could not connect to event connection manager.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET-4-OPD_ALARM ### Response: (Severity: 4), (Category: L2), (Description: The specified received Optical Power Degradation Alarm has been declared or released. interface: interface on which alarm is set/cleared alarm: alarm being asserted i.e. RX-OPD status: set/cleared), (Recommended Action: If alarm is seen: Link quality degraded beyond configured threshold. Check if the cable is faulty.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_RP-3-BTREE_RESET_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to reset btree shared memory function ptr. This is a software programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTAGENT-2-SWP_REVERTED ### Response: (Severity: 2), (Category: INFRA), (Description: When system(node) reloads without commit, committed swp is copied to active swp. This gets displayed when user expliciitly reloads without commit or when the system reloads silently after a reload.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-4-FINGERPRINT_CACHE_CHANGED ### Response: (Severity: 4), (Category: INFRA), (Description: The file that is used to cache the run time fingerprint information has been modified. This may be as a result of an attempt to falsify the run time fingerprint information, to cover up malicious changes to installed software. Fingerprint cache regeneration is being scheduled.), (Recommended Action: Ensure that only authorized people have access to the router. Wait for the cache generation status returned from yang with the active/committed packages to indicate that cache generation is up to date, at which point the results active/committed packages data can be relied on again. This may take at least 5 minutes.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-6-ERR_ASIC_RESET_DEFERRAL ### Response: (Severity: 6), (Category: FABRIC), (Description: The annunciated error occurred relating to asic deferral.), (Recommended Action: In one of the persistent storage devices (harddisk:/, disk0: etc.) on the DSC's RP that was active at the time the message was emitted, a file may have been created under a directory called asic_snapshots/ for this occurrence. The name is of the format 'sponge_debug_snapshot.node__CPU0.<[first/latest]>' Collect that file if present and save it to the case.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_IO-3-FIB_BIND_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The IPv4 EA thread could not bind to FIB due to the mentioned error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check with fib_mgr process(PI FIB) on the reason of failure to bind to FIB.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-bandwidth underflow feature? ### Response: The MPLS TE auto-bandwidth underflow feature allows auto-bandwidth to react more quickly to drops in traffic flow by triggering an immediate bandwidth adjustment when the measured rate drops below a configured underflow threshold. It aims to free up bandwidth on the tunnel path more promptly when traffic decreases significantly. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-3-ACP_DIKE_TO_NBR_FAILED ### Response: (Severity: 3), (Category: SERVICES), (Description: 'Autonomic Network Control plane - Failed to create DIKE ' 'tunnel to neighbor'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-6-INFO_LOG ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an information log.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_SYSDB_DATALIST_FREE ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHDLCDLL-3-ERR_TRACE_REGISTER ### Response: (Severity: 3), (Category: L2), (Description: An attempt to register with the tracing infrastructure failed. This will mean that tracing for the cHDLC Netio DLLs will not be available.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS LDP session protection feature? ### Response: The MPLS LDP session protection feature provides a means to protect an LDP session between directly connected neighbors in the event of an interface failure. It uses a targeted hello adjacency as a backup to maintain the session. It is enabled with the mpls ldp session protection command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-7-LINK_STATUS_CHANGE ### Response: (Severity: 7), (Category: PLATFORM), (Description: The DMAC link state changed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-5-PEC_PECINSERTED ### Response: (Severity: 5), (Category: PLATFORM), (Description: The expansion card is inserted.), (Recommended Action: None,informational purpose only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-AIS_EXPIRY_TIMER ### Response: (Severity: 4), (Category: L2), (Description: An error occurred while restarting the AIS expiry timer for the local MEP specified in the error message. This could cause a received AIS or LCK signal to be incorrectly reported as having stopped.), (Recommended Action: If the error persists and the local MEP continually reports the received signal as starting and stopping, the problem may be corrected by restarting the cfmd process on the node where the problem is being reported.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-IO_MNT_ROMMON_LOW_MEM ### Response: (Severity: 3), (Category: MEDIA), (Description: Could not get enough memory while trying to initialize nvram.), (Recommended Action: 'Router running low in memory. Reboot if possible.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-3-SYSDB_BAG_DECODE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The system is attempting to process a policy object set or named policy and cannot decode the object.), (Recommended Action: Look for out of resource conditions. If memory is low, then restart the policy_repository process and reapply the configuration. Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the process. This resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: Multilink_CLNT-3-INVALID_ARG ### Response: (Severity: 3), (Category: L2), (Description: Cannot retrieve bundle info as Invalid arguement was passed in function.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMHAC-7-ERR_DLL_INIT ### Response: (Severity: 7), (Category: OS), (Description: The Platform Manager HA DLL encountered an internal software error. The debugging services could not be initialized. This problem should rarely happen. Restarting the Platform Manager HA process might recover the problem), (Recommended Action: There is no action required because the client process should handle this error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-7-DEBUG_QSM ### Response: (Severity: 7), (Category: OS), (Description: debug print before qsm_stat), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMDR-5-SERVER_INIT_DEBUG_FAILED ### Response: (Severity: 5), (Category: OS), (Description: 'Debug utility registration failed.' 'Debug functionality may not work properly.' 'IMDR will proceed without fail.'), (Recommended Action: 'Restarting the process may resolve the issue.' 'If the problem persists after some tries, contact tac.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-ZERO_LEVEL ### Response: (Severity: 3), (Category: OS), (Description: No level started placeable processes found in the table.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-6-INFO_SHUTDOWN ### Response: (Severity: 6), (Category: SECURITY), (Description: System shutdown.), (Recommended Action: 'NO ACTION') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PM_TEST-6-UPDATE_ERR ### Response: (Severity: 6), (Category: PLATFORM), (Description: hfr_pm test encountered an error and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: This is just test software which the customer does not get. so there is no actiom required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-EVENT_MGR_CE_TFTP ### Response: (Severity: 3), (Category: IP), (Description: The CE-TFTP server process exited due to specified reason mentioned in the message related to the event handler to handle the notification event from the EthServer when a new packet arrives.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-FAILED_INIT_LTRACE ### Response: (Severity: 7), (Category: INSTALL), (Description: The install notification library was unable to initialise the trace buffer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE_CLIENT-4-WARNING ### Response: (Severity: 4), (Category: SECURITY), (Description: Internal Warning.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-INVALID_ABS_SID ### Response: (Severity: 4), (Category: ROUTING), (Description: When prefix SID value is configured as absolute label value, it should be within the SR Global Block configured on the router (default 16000-23999). The prefix SID will not be used until this config inconsistency is resolved.), (Recommended Action: Fix the configuration such that the absolute SID value lies within SRGB. Ignore if this is already done and warning will repeat until this is fixed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-3-LTRACE_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: ltrace initialization failed), (Recommended Action: If continuous, contact tech-support Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EM-7-EEMS_FILE_OPEN ### Response: (Severity: 7), (Category: HA), (Description: Failed to open the given file due to some internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFV3_POLICY-3-ORA_INSTBUILD ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error in policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-5-SKIPPED_REPARTITION_EUSB ### Response: (Severity: 5), (Category: PLATFORM), (Description: Some existing eUSB may have wrong FS or partitions. Check if need to reformat the eUSB. This message will get printed if eUSB is unable to repartition and prints with skipping repartition.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-MSGQ_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: Message Q operation failed.), (Recommended Action: Restart process 'cgn_ma'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_2_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERROR_SHOW ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, show fail error information), (Recommended Action: This is a warning that some information is missing from the output of the show command.PLease collect the show command, console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>). Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-6-SYSDB_BLOCK_SERVICE ### Response: (Severity: 6), (Category: OS), (Description: SSM process detects sysdb service is not available.), (Recommended Action: Collect system log information for the sysdb. Collect show tech sysdb, show tech ssm. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM_TEST-6-RCVD_UPDATE ### Response: (Severity: 6), (Category: IP), (Description: Update received), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA-5-WARN_INSUF_MAC ### Response: (Severity: 5), (Category: L2), (Description: A client has request more MAC addresses than the MAC allocation process can provide.), (Recommended Action: If the pool is exhausted and MAC address configuraion is allowed, configure more MAC addresses. Otherwise reduce scale.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-4-SR_POL_REQ_POL_TYPE_MISMATCH ### Response: (Severity: 4), (Category: OS), (Description: Policy has different type (per-flow or per-destination) than the new candidate-path type add request. Therefore, the new request will be dropped. If it is required to change the type, the policy should be removed completely before the type is changed.), (Recommended Action: Correct the configuration so all candidate-paths have same policy type (i.e. per-flow or per-destination). If it is required to change the policy type, remove the policy completely and then add candidate-paths of the other type.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-6-INFO_GENERAL ### Response: (Severity: 6), (Category: SECURITY), (Description: The sshd encountered some problem in genric nature or plain information.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_BQS-6-SRTMEMLOW_CLEAR ### Response: (Severity: 6), (Category: L2), (Description: CPP BQS HW schedule resources have recovered from critical threshold.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-3-ERR_DMA ### Response: (Severity: 3), (Category: FABRIC), (Description: A hardware error occurred while a DMA transfer initiated by the FQM process was taking place. This means certain data requested by the FQM process will not be available.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-FGID_FREE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while freeing FGID - exceeds max number of tries for freeing FGID - number of fgid passed exceeds set limit dues to message size limit), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-6-ECM_FAILURE ### Response: (Severity: 6), (Category: PLATFORM), (Description: During the set up of the connection to fabric server, one of the calls failed. This is considered a critical failure.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-FIA2NPU_1_PKT_MAXLEN_ERR_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet maximum length error on FIA to NPU-1 interface on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSUDIR-4-ABORT_CLEANUP_TIMEOUT ### Response: (Severity: 4), (Category: INSTALL), (Description: ISSU Director did not recieve a notification from ISSU Manager indicating abort cleanup was successful. ISSU Director has made a best effort attempt to clean up any stale system resources and terminate any stale ISSU Manager processes.), (Recommended Action: Verify that the software nodes are in the correct state by running 'show platform' and that there are no stale virtual machines. Otherwise contact Cisco support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_HFR-7-ERR_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered the specified error during the initialization sequence. This facility is deemed crucial and hence the process is automatically restarted on this failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD_NETIO_DLL-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Forwarder encountered a memory allocation failure error), (Recommended Action: No Action required Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: tunnel_ea-3-PLATFORM_MANAGER_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This is typically an internal error in the software. The software failed to create the interface on the engine..), (Recommended Action: If there is a problem, it might be cleared by restarting tunnel_ea. If the problem persists, copy the error message as it appears on the console and any noticeable side effects. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-6-MEMBER_COMPATIBILITY ### Response: (Severity: 6), (Category: L2), (Description: A configuration change has meant that a link is now incompatible (or compatible) with the other members of the bundle, or the bundle is operating in a mode that is incompatible with the member's configuration. The reason for the incompatibility at the time of raising the alarm is supplied in the message.), (Recommended Action: No action is required; however, any link that is incompatible will not be used in the bundle. In order to make the link compatible, refer to the reason given in the message. Check the configured mode of operation (LACP active/passive or disabled, i.e. mode 'on') and bandwidth of all the links within the bundle or the bundle configuration to resolve the incompatibility.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-RX_CH_LO_PWR ### Response: (Severity: 3), (Category: FABRIC), (Description: The POD detects a low power on a channel. This is a precursor to Rx LOS errors in the channel. The link is now marginal, and the superstar Rx link may be seeing correctable errors. Although the link is still working, it is marginal and can become inoperational in due course. This is also likely due to contaminates in the optical cable and/or connector. Please check if the optical cable and/or connector are secured, and clean the components as necessary.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_HFR_LIB-7-SERIAL_BAUDRATE ### Response: (Severity: 7), (Category: PLATFORM), (Description: Display the serial baud rate value.), (Recommended Action: Debug message only. No action is required..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-MSG_REPLY_ERR ### Response: (Severity: 3), (Category: OS), (Description: msg_reply() failed to send the reply.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHER_CTRL-3-MUTEX_OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_3_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser temperature greater than or equal to the high temperature warning threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-PWR_EXCEEDED_SHUTDOWN ### Response: (Severity: 2), (Category: PLATFORM), (Description: the power budget enforcement progressive configuration is enabled in the router and the current power usage exceeds the configured threshold. Hence the least priority is being shutdown.), (Recommended Action: Ensure that sufficient power is available. Reload the affected card to bring it up.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the main components of RPL on IOS-XR? ### Response: The main components of RPL on IOS-XR are\n- Policies - Contain a series of statements to evaluate routes and apply actions\n- Sets - Groups of elements like prefixes, AS paths, communities that can be referenced in policies\n- AS path sets - Define AS path filters\n- Community sets - Define community filters\n- Prefix sets - Define prefix filters\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-DEBUG_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: PLIM process encountered a software initialization error. LC will not work due to this error .), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed. There was problem with hardware or software initialization. This problem can be resolved by reloading the LC 'hw-module location <> reload'. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-1-NP_RESET_FAIL ### Response: (Severity: 1), (Category: PLATFORM), (Description: This message indicates that NP is not out of reset successfully, this would affect the traffic on the interfaces that belongs to this slice.), (Recommended Action: Collect 'show tech-support ethernet interfaces' for further analysis) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_LOCAL-3-INVALID_PROC_ID ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The process was unable to get a valid local interface process ID from the environment and so is not able to instantiate the correct local interface owner processes.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_TDM-7-DUP_TABLE ### Response: (Severity: 7), (Category: HA), (Description: During registration, two copies of a table were found in the CDM store at the same version. This indicates corruption in the CDM store.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPABRG-6-HW_INFO1 ### Response: (Severity: 6), (Category: L2), (Description: Marmot spabrg driver informational message), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ILITE-7-COMMON_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: The CAI C2C I-lite library encountered an error related to memory or data value.An error would be reported to the client application which should handle this condition appropriately.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure RSVP for MPLS-TE tunnels in Cisco IOS XR? ### Response: To configure RSVP for MPLS-TE tunnels, use the 'mpls traffic-eng tunnels' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#mpls traffic-eng tunnels <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_PWHE-3-EA_STATE ### Response: (Severity: 3), (Category: L2), (Description: The PWHE EA process failed to update the state of a tunnel interface.), (Recommended Action: Collect debugging information, shut/no-shut tunnel interface. If the above action doesn't fix the problem, remove tunnel interface, re-create tunnel interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS traffic engineering autoroute feature? ### Response: The MPLS traffic engineering autoroute feature allows IGP routes to be automatically routed over MPLS TE tunnels. This provides IGP shortcuts using the TE tunnels. Autoroute can be announced globally for all tunnels or on a per-tunnel basis. It is enabled with the tunnel mpls traffic-eng autoroute announce command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL-3-EVMGR_API_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An internal error has occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-4-CRS_X_MSC_UNKNOWN_SW_REV ### Response: (Severity: 4), (Category: PLATFORM), (Description: The line card FPGA is reporting a different software revision.), (Recommended Action: Upgrade FPDs using upgrade hw-module FPD command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBMIRROR-6-INFO_INOTIFY_GENERAL ### Response: (Severity: 6), (Category: MGBL), (Description: mirror common libs general inotify info. This is probably not an issue, but you can run `show mirror` to verify.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFD_HELPER-2-CRITICAL_ERROR ### Response: (Severity: 2), (Category: MGBL), (Description: A critical error was encountered. The failure of this can be critical to general system operation. If the same error is seen more than 5 times, contact Cisco TAC support because a reboot of the node may be required.), (Recommended Action: Provide the message details to Cisco Support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FM-6-CLIENT_ACTIVITY ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Fault Raised), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-6-UNSUPPORTED_OPTICS ### Response: (Severity: 6), (Category: L2), (Description: The SFPPLUS optics inserted in the given port is not supported on this PLIM.), (Recommended Action: Verify the SFP+ is supported in the topaz plim installation manuals. Replace this optics with a Cisco supported optics.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMDR-6-TEST_CLIENT_ERROR_TC ### Response: (Severity: 6), (Category: OS), (Description: Status information while enabling test client to exercise the error test cases.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-4-ASIC_ERR_BACKUP ### Response: (Severity: 4), (Category: FABRIC), (Description: Report failures from asic_error backup triggered during card bringdown.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What load balancing options are available for MPLS traffic in Cisco IOS XR? ### Response: Cisco IOS XR supports several load balancing options for MPLS traffic: 1) Per-destination load balancing (default) where packets for a given FEC are always forwarded over the same path. 2) Per-packet load balancing where successive packets for a given FEC may take different paths. 3) Flow-aware load balancing (FAT) where packets belonging to the same flow are always sent over the same path. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'update-limit' command in IOS XR BGP configuration? ### Response: The 'update-limit' command allows limiting the number of prefixes that can be received from a BGP neighbor within a specified time interval. If the limit is exceeded, the BGP session is torn down. This provides protection against a misconfigured or malicious BGP neighbor that sends an excessive number of prefixes, which could consume all the memory on the router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_LTRACE_BUFFER ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occurred while accessing a tracing buffer. This may be due to resource starvation or an internal software programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-INIT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: This is an init error. The system should have taken the actions to recover itself.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_ENA-6-TCP_FAIL ### Response: (Severity: 6), (Category: MGBL), (Description: TCP accept call failed, the HTTP server can't function.), (Recommended Action: No action is required. The server will automatically restart) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-6-WARNING_WRAPPER ### Response: (Severity: 6), (Category: ROUTING), (Description: A function call failed unexpectedly - this is probably a system problem), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_LSD-7-ERR_CLIENT_FAULT ### Response: (Severity: 7), (Category: ROUTING), (Description: Client error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mini' composite PIE (e.g., comp-hfr-mini.pie-3.6.0)? ### Response: The 'mini' composite PIE is used for upgrading an already running IOS XR system. It includes all the packages contained in the IOS XR Unicast Routing Core Bundle. Installing and activating the mini PIE upgrades the router to a new IOS XR version. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISKUTIL-3-INIT_ERROR ### Response: (Severity: 3), (Category: MEDIA), (Description: An unexpected initialization error condition encountered. System backup utility may not work properly), (Recommended Action: Collect system log information. Do not run system backup utility. Check storage media to see whether they are accessible. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_CLIENT-7-ID_INVALID ### Response: (Severity: 7), (Category: OS), (Description: Invalid client_id is created.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LSLIB-6-INFO ### Response: (Severity: 6), (Category: ROUTING), (Description: An informational message for user.), (Recommended Action: No action required - these are messages for information only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-3-INVALID_INI ### Response: (Severity: 3), (Category: INFRA), (Description: Ini file found is invalid.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to verify an L2VPN VPLS bridge domain? ### Response: To verify the status of an L2VPN VPLS bridge domain, use the 'show l2vpn vfi' command. show l2vpn vfi <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-4-MAP_SERVER_SITE_EID_PREFIX_LIMIT_CONFIG ### Response: (Severity: 4), (Category: IP), (Description: 'The newly configured limit is less than the current ' 'EID prefix count.'), (Recommended Action: 'Issue \'clear lisp site\' for limit to take effect.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL-3-NEGATIVE_CURRENT_COUNT ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Tunnel count has been decremented till it became negative. process tunnel_infra will restart to recover from the situation.), (Recommended Action: Ideally this should never happen and points to a serious bug in pfi/tunnel/infra File a tracking DDTS if it happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_7_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN-4-AUTHEN_FAILED ### Response: (Severity: 4), (Category: SECURITY), (Description: This is an error message from debug module of aaa component. This might have been caused by 1. Entering wrong username/password. 2. The user is not configured on the box and hence can not login.), (Recommended Action: Please check for the correctness of username/password) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_ACTIVATE ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the activation of the process. Activation occurs when the card transitions to ACTIVE state. This error resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMDR-5-SHIP_REG_ERROR_COUNTERS_FAILED ### Response: (Severity: 5), (Category: OS), (Description: 'Ship registration for error counters failed.' 'Ship functionality may not work properly.' 'IMDR will proceed without fail.'), (Recommended Action: 'Restarting the process may resolve the issue.' 'If the problem persists after some tries, contact tac.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_RA_INTR_VQI_DEQ_QERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_RA_INTR_VQI_DEQ_QERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ROMMON_BURNER-5-version ### Response: (Severity: 5), (Category: PLATFORM), (Description: Invalid ROMMON version to RP console.), (Recommended Action: No action is required..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_HFR-7-ERR_THREAD_ATTRIBUTE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while setting the thread attribute during the process initialization sequence. This is crucial for the process and is automatically restarted on this failure.), (Recommended Action: If the problem is experienced only by this process in the system, restart the fabric server process by executing the following command at the CLI of the active RP: process restart fab_svr location If problem either persists (following a process restart) or also noticed on other processes then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-NSR_NII_BRINGUP ### Response: (Severity: 4), (Category: ROUTING), (Description: An unexpected error occurred while IS-IS bringup NII intf and it's timer on the interface not running.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-3-RECORD_TYPE_MISMATCH ### Response: (Severity: 3), (Category: OS), (Description: A feature record has different type with current software.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_CONF_PRX-3-ERR_SHUTDOWN ### Response: (Severity: 3), (Category: SECURITY), (Description: System shutdown.), (Recommended Action: 'SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TAMSVCS-3-FAILED_CLEANUP ### Response: (Severity: 3), (Category: SECURITY), (Description: tamsvcs process failed to cleanup the hybrid tam DB.), (Recommended Action: 1) show tech-support tam 2) process shutdown tamsvcs_tamm location 3) Move/Remove the tam DB as follows eXR/Lindt: /misc/config/SWTamRoot cXR:/disk0:/SWTamRoot 4) process start tamsvcs_tamm location Data objects created earlier in TAM-DB will be lost and TAM will start with fresh DB. if any application have created objects then those application have to re-create it again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-7-BADPATH ### Response: (Severity: 7), (Category: MEDIA), (Description: Could not attach pathname), (Recommended Action: Reboot the router if possible. If not try to start it from the command line. If that too fails Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-3-PTHREAD_CREATE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: Failure occured while creating shim partner thread.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PM-6-IFH_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The Service Platform Manager encountered an provisioning info.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect 'show log location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-7-DEBUG_STAT_HEX ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-3-PTHREAD_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Failed in a pthread function.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTU0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_HQ_SEQ_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue sequence error on XAUI 0 HQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHER_CTRL-4-MLAN_COUNTER_OVFL ### Response: (Severity: 4), (Category: PLATFORM), (Description: A runtime failure occurred in Ether-Ctrl process. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code and a string interpretation of the error code.), (Recommended Action: Collect console log and the following information. - sh platform - sh install summary - sh controller mlan port-counter <> location <> - sh controller mgmteth <> location <> stats - sh interface mgmteth <> location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_ACL-6-IPACCESSLOGS ### Response: (Severity: 6), (Category: ACL), (Description: A packet matching the log criteria for the given access list was detected. These messages are issued whenever access lists are configured with the 'log' option and matches with the access-list that is used by routing protocols. This message is seen for the first match and for each match after the hit count is greater than 0x7FFFFFFF(2147483647).), (Recommended Action: This is information only message, no action required No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-HW_TX_RFD_EMPTY ### Response: (Severity: 3), (Category: PLATFORM), (Description: NP detects TX_RFD_EMPTY and reported through interrupts), (Recommended Action: No specific actions needed. The software should be able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDSUTILS-3-RING_INIT ### Response: (Severity: 3), (Category: OS), (Description: Failed to initialize the ring.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-4-MGR_L2TP_SESSION_ID_SPACE ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: L2TP session id space configuration is incompatible in the system. This may prevent new sessions from coming up . Also , existing sessions may be affected.), (Recommended Action: Please configure 'no l2tp session id space hierarchical') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-WARN_SYSDB_EDM_REG ### Response: (Severity: 4), (Category: SNMP), (Description: Failed to register as EDM. The access to SNMP statistics and MIB information through 'show snmp' CLI command will not be available. This is likely due to an internal software error.), (Recommended Action: Restart snmpd process.if still noticed this message check the state of snmpd process 'show process snmpd' and contact technical support representative. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-S2L_BFD_UP ### Response: (Severity: 5), (Category: ROUTING), (Description: The BFD session for the specified interface destination came up. \ The first argument is the tunnel name. The the second argument is \ the signalled name, and the last argument is the Sub-LSP destination. \), (Recommended Action: None. This is a solicited message (by 'logging events bfd-status' \ configuration under tunnel interface) and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX-2-VER_TRANSLATE_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: There was an fail during translate of the platform version. Plaform info version may not be same as the driver, the error message has detailed information. Version translate fail will usually result in process restart in an attempt to translate the correct platform version.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-4-CARD_PCI_NTB_SWITCHOVER_DONE ### Response: (Severity: 4), (Category: PLATFORM), (Description: Card PCI Non-Transparent Bridge Switchover operation is completed without any error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-API_FAIL ### Response: (Severity: 3), (Category: MGBL), (Description: 'An API failed due to the mentioned error'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_3_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCI_HAL_SATORI-3-ERR_TX_PKT ### Response: (Severity: 3), (Category: PLATFORM), (Description: CCI HAL SATORI Packet transmit error.), (Recommended Action: Execute spp_pdma_show_ltrace from the kshell of the card where this message was seen.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-RSPI_DIP4_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: RxSPI DIP4 error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-6-UNKNOWN ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: A VPDN session has been terminated. The category of the termination event is unknown), (Recommended Action: Please examine the human-readable error message that appears in the log and conduct the first level of troubleshooting based on the info in the message. If the root cause is still not clear, collect the required info and forward it to technical support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_CDM ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA encountered an error using the CDM Service. The error message describes what operation has failed and why it failed. The most likely reason for this a low memory condition but the error could also be caused by a programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYNCFS2-7-CLIENT_ERR ### Response: (Severity: 7), (Category: MEDIA), (Description: Failed function call.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_EDM-3-LIST_ADD_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The attempt to add an item to an external data manager list has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-NODE_HBLOSS_RESET ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is being reset because it failed to detect heartbeat pulses. Debug information would have been collected before the reset operation and then saved under harddisk:/shelfmgr_debug directory (debug files collected for each node will be created under its own subdirectory) after the node recovers from the failure. Also crashinfo and core file would have been created as part of the reset opeartion under harddisk:/.), (Recommended Action: Collect heartbeat loss debug files of the affected node from the harddisk:/shelfmgr_debug directory and the associated crashinfo and core file befre contacting Cisco for technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-4-SRP_NR_CLIENT_UNREG ### Response: (Severity: 4), (Category: HA), (Description: An unexpected error condition encountered.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_HW_OFFLOAD-2-NO_MEMORY ### Response: (Severity: 2), (Category: PLATFORM), (Description: Unable to get shared memory window info), (Recommended Action: Provide the following log: Collect console logs and output of - show memory summary location <> - show shmwin summary location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-GET ### Response: (Severity: 7), (Category: MGBL), (Description: An error occurred invoking an MDA function. This could be because the object to fetch does not exist. The details are in the error string.), (Recommended Action: Check that the requested object exists. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_HT1_EOC ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an HTDP EOC error on the HT1 interface. HT0 EOC Error indicates that a packet has arrived to be sent on the HT link but the link is not active.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-3-FLASH_SELECT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occured while trying to get ROM selection info.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key preparation steps needed before installing IOS XR? ### Response: Some of the key preparation steps needed before installing IOS XR include: identifying the desired IOS XR release version and optional packages, determining mandatory SMUs, checking hardware compliance and memory requirements, preparing the boot device, and setting up network connectivity to the router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-CDR_REG_NOTIF_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric:CDR driver failed to register for notification from shelf-manager. Please check with shelf-mgr team.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAA-6-OPEN ### Response: (Severity: 6), (Category: SECURITY), (Description: This is an info message from debug module of aaa component. This indicates that user has succesfully authenticated.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-7-ERR_DMA ### Response: (Severity: 7), (Category: FABRIC), (Description: An error occurred while a DMA transfer initiated by the FQM process was taking place. This means certain data requested by the FQM process will not be available.), (Recommended Action: If the issue persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFLOW-6-INFO_BUFFER_SIZE_EXCEEDED ### Response: (Severity: 6), (Category: MGBL), (Description: This is an informational message to indicate that the specified flow monitor map buffer has been exceeded. This buffer is used to transiently keep sFlow records in memory.), (Recommended Action: If this message is being issued too often, you might consider increasing the export rate of the monitor map by the command 'cache timeout rate-limit'. The rate-limit is in use to smoothen out transient surge in traffic. If the message is seen less frequently, you may consider increasing buffer size to hold more entries by 'cache entries' command. Note that the maximum cache size is 1,000,000 entries and it may put a strain on memory consumption in the LC. If these measures are not effective, consider lowering the sampling rates.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-ANR_WHITELIST_CONFIG ### Response: (Severity: 6), (Category: SERVICES), (Description: 'The autonomic registeration authority has been ' 'configured with white list and will allow only ' 'these devices to enter its network'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBC-6-L6 ### Response: (Severity: 6), (Category: SERVICES), (Description: Log level in sbc app is set to higher than 40 and less than 50. This is an info message.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FHRP_OUTPUT-3-ERR_MAIN_QUEUE ### Response: (Severity: 3), (Category: IP), (Description: The FHRP Output process failed to queue an event to the Main thread. If possible then the FHRP Output process will attempt to recover and retry. Clients of the FHRP output process (such as HSRP and VRRP) will observe inconsistent behavior until this is resolved.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-HW_GASPP_READ_BUS_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The user may have entered an invalid address, or else there is a HW problem.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCMD-3-ASSERT_INFO ### Response: (Severity: 3), (Category: ROUTING), (Description: Provides information about the assert in RCMD.), (Recommended Action: Report to Technical Support. This provides information about the assert occured in RCMD process. Please take technical support assistance to verify that RCMD process has been removed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_LIB_ACCESS-3-SERVER_CONNECT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: A communication problem occurred between the MBI client and server, perhaps because the communications infrastructure is not yet up. The MBI operation in progress will not be carried out.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-4-ERR_THREAD_CREATE ### Response: (Severity: 4), (Category: L2), (Description: MFR MA encountered an unexpected error creating a new thread. The process will restart to attempt to recover. This is possibly due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-4-ISSU_SUPPORT ### Response: (Severity: 4), (Category: ROUTING), (Description: ISSU in EIGRP works on top of NSF and GR. If NSF is disabled, during ISSU, EIGRP will not be able to retain the routes learnt from its peers and may result in traffic loss.), (Recommended Action: If routes learnt by EIGRP needs to be retained during ISSU, enable NSF using \'no nsf disable\'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-3-LRD_DLRSC_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The verifier application would need to listen to LRd events to figure out if it is running on a dlrsc The error refers to processes not running on the dLRSC %s - process name %s - error/warning condition), (Recommended Action: Try for process restart If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_3_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-FANTRAY_COMM_CLEAR ### Response: (Severity: 2), (Category: PLATFORM), (Description: System SW communication with fan tray re-established.), (Recommended Action: None required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-3-CALLBACK_WRONG_THREAD ### Response: (Severity: 3), (Category: OS), (Description: A callback from the IOX-XR infrastructure was not handled by the PCE process because it was received in the wrong thread. The PCE process may now be in an inconsistent state with the rest of the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The pce_server process may be restarted in order to recover from this situation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-READ_TX_RX_TIMEOUT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected a timeout on some bus), (Recommended Action: Please try to correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-BPM_RD_RECONSTRUCT ### Response: (Severity: 3), (Category: ROUTING), (Description: The RD value for the VRF failed to be reconstructed after RPFO.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-UNSUPPORTED_IFTYPE ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The interface name does not correspond to a supported XR interface type, i.e. MgmtEther or GigabitEthernet.), (Recommended Action: Check the type of XR interfaces in the XR_INTERFACES environment variable.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-6-AGENT_READY ### Response: (Severity: 6), (Category: LICENSE), (Description: Smart Agent is initialized and ready for use.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-PLAT_DB_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: CPP driver failed to query platform data base.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-FXC_LOCAL_SWITCHING ### Response: (Severity: 3), (Category: L2), (Description: For an EVPN VPWS flexible xconnect (FXC), the calculated Ethernet tag may be used by at most two Access Circuits(AC) to setup AC-AC Local Switching. It is impossible to Local-Switch more than 3 ACs. The same set of rewrite tags to enable Local switching was configured on more than two Access Circuits in the same FXC. Up to two identical Ethertag rewrites are supported in the FXC/EVI on different interfaces, 3 (or more) is unsupported. The Ethernet tag is derived from the interface encapsulation and rewrite tags.), (Recommended Action: Modify the encapsulation/rewrite tag for current interface so the calculated Ethernet tag is used at most twice per FXC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-3-ERR_SYSDB_DATALIST ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: USB-2-DEV_EUSB1_NOT_RESPONDING ### Response: (Severity: 2), (Category: PLATFORM), (Description: EUSB1 device not responding), (Recommended Action: Please attempt the following: If dual RSP, and the problem is on the active RSP, issue 'redundancy switchover' If the problem is on the standby/simplex RSP: Restart low level usb driver via ksh, 'kill io-usb_pid' Failing which, Restart usbstack 'process restart umass-enum' Failing which, Reload RSP If problem persistes, replace EUSB devices If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-3-EDM_REG_FAILED ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to register as a SysDB EDM.), (Recommended Action: Please include the output of the following commands: - show tech-support lpts - show tech-support sysdb - show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE tunnel load-share feature? ### Response: The MPLS TE tunnel load-share feature allows the control of how traffic is load-balanced between two or more parallel TE tunnels to the same destination. By default, load-balancing is based on a hash of the packet header fields. Optionally, the load-share value can be specified manually to control the proportion of traffic to each tunnel. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-6-INFO_DNS_HOSTNAME ### Response: (Severity: 6), (Category: MGBL), (Description: 'Time delay due to DNS server not reachable.'), (Recommended Action: parsing is taking a long time - DNS is not reachable because it has an issue) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL-3-INIT_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The tunnel process responsible for the creation of tunnel interfaces failed during initialization. The process will exit and as a result, no tunnel interfaces can be configured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_LASER_CASE_TEMP ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-BOOTED_WITH_FALLBACK_SOFTWARE ### Response: (Severity: 6), (Category: INFRA), (Description: The fallback bootloader menu entry has been booted, as is expected to happen when the router is reloaded before executing: install commit. This is the software that was running before the most recent transaction was started. If the router was explicitly reloaded by the user before install commit, then this is expected. If this syslog is seen under other scenarios, then this is unexpected.), (Recommended Action: If the user reloaded the system after performing an install transaction but before committing the software, then: No action is required. If the router was expected to reload with new software (as part of an install operation), then: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRv6-4-BLOCK_OOR_YELLOW ### Response: (Severity: 4), (Category: ROUTING), (Description: The SRv6 SID manager database has reached the blocks resource warning threshold for dynamically allocated local SIDs. Details about the limit can be seen with show segment-routing srv6 manager command. Details about the block can be seen with show segment-routing srv6 block. The list of local SIDs can be seen in show segment-routing srv6 micro-segment local-sid), (Recommended Action: If this threshold is regularly reached, it may be a sign to reduce scale of Segment Routing IPv6 entries by changing topology or VPN allocation mode in BGP from Per CE to Per VRF) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-INSTALL_OPERATION_CANCELLED ### Response: (Severity: 6), (Category: INSTALL), (Description: An install operation was cancelled via a user prompt. Use 'show install log detail' for more details.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-BA_UNSPEC_FAIL_8 ### Response: (Severity: 3), (Category: IP), (Description: In non-De-Registration PBUs, Lifetime should not be Zero.), (Recommended Action: If the issue is seen repeatedly, do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-5-CORRUPTED_MSG ### Response: (Severity: 5), (Category: OS), (Description: The message received by an application had inconsistent values.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-3-TIMER_INIT ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the TCP process sets up and initializes the various TCP timers.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-6-OIR_TRANSCEIVER_INSERTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This informational message indicates that the optic interface module was inserted on the given interface.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWR_MGMT-2-FIRMWARE_UPGRADE_PWR_POWEREDOFF ### Response: (Severity: 2), (Category: PLATFORM), (Description: 'power module firmware upgrade with out power feed cable makes incosistent firware upgrade within power sub-modules'), (Recommended Action: 'Please connect power cables(s) and try again.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-3-SPI_INIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error occured during initializing SPI. This might be a program level error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-EVAL_EXPIRED_WARNING ### Response: (Severity: 3), (Category: LICENSE), (Description: The device evaluation period has expired.), (Recommended Action: Use the \'license smart register idtoken \' CLI to register \ this device.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_SKP-7-ERR_BAG_REGISTRY ### Response: (Severity: 7), (Category: ROUTING), (Description: The MFWD-SKYWARP library encountered internal error during sysdb/edm init setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-THREAD_POOL_FAIL ### Response: (Severity: 3), (Category: OS), (Description: OBFL manager will restart in this case as thread pool is necessary for OBFL manager to function. In this scenatio OBFL will restart and recover by itself.), (Recommended Action: If the issue is seen after restart, Please collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-7-SLOT_DECODE_FAILURE ### Response: (Severity: 7), (Category: OS), (Description: An error happened for a nodeid decoding.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-4-POLICY_CLEANUP_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: When deleting the specified policy, the policy_repository process encountered a problem. This could leave memory unfreed.), (Recommended Action: If the policy_repository process is using an excessive amount of memory, consider restarting it with 'process restart policy_repository' to clean up any unused memory. Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CERR_LIB-7-PTHREADKEY ### Response: (Severity: 7), (Category: OS), (Description: The infrastructure library was unable to obtain a thread key for thread private data storage.), (Recommended Action: Check to see if sufficient memory resources remain for normal operations. Add memory if necessary.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBIPV6PROTO-3-GET_MTU_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The transport fails to get the MTU from the network protocol process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PA_FF-4-MSG_CLINFO_GET_DATUM ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when accessing a client info structure.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-3-ERROR ### Response: (Severity: 3), (Category: OS), (Description: A function call returned an unexpcted error. Possible resource shortage or coding error. Monitor CPU,memory conditions and process crashes in that timing window.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-LABEL_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred whilst initialising the LABEL thread. This could be caused by failure to allocate resources or by errors when calling the MPLS label manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSEC_SVI_EA-3-NOT_FOUND ### Response: (Severity: 3), (Category: SERVICES), (Description: The IPSec SVI EA process received a request to process an interface that does not exist in its database. This indicates some sort of internal inconsistency.), (Recommended Action: It may help to restart the IPSec SVI EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'overload' command in IS-IS? ### Response: The 'overload' command is used to set the overload bit in the IS-IS LSPs. This indicates that the router should not be used as a transit router, but can still be used as a source or destination for traffic. This is useful when the router is undergoing maintenance or is in a transient state. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSH_IPC_EM-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: osh ipc em errored within driver dll.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-HW_MODULE_PROFILE_TE_TUNNEL_CHASSIS_CFG_CHANGED ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. If the hw-module command is used to configure the user defined configs, there will be inconsistency between the user config and the hardware. Since the driver in LC has already started the asic initialization process before this config is received. Needs attention with reloading the chassis.), (Recommended Action: System is inconsistent. Need to reload chassis for new values to take effect. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBCORE-3-BAG_REG_FAIL ### Response: (Severity: 3), (Category: SNMP), (Description: An internal operation failed. The system will attempt to recover.), (Recommended Action: Copy the message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP transport connection-mode passive feature? ### Response: The BGP transport connection-mode passive feature allows a BGP router to only passively establish TCP connections for a peer, rather than actively attempting connections. The peer must be configured to actively establish the connection. It is configured with the neighbor transport connection-mode passive command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_SYSDB_SET ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-4-ERR_BACKEND ### Response: (Severity: 4), (Category: OS), (Description: Sysdb backend api call failed.), (Recommended Action: Please collect the output of the following commands: - show tech-support lpts - show tech-support sysdb - show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RASF-4-NO_BASE_COMPARE ### Response: (Severity: 4), (Category: ROUTING), (Description: This is a logic error in the construction of one of the ORA entities. The compare for checking two different route values against each other was missing.), (Recommended Action: This is not an error message) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-DISK_ALARM_ALERT ### Response: (Severity: 3), (Category: HA), (Description: When some monitored disk's usage is above 85%.), (Recommended Action: The indicated disk device may be running out of space. Determine if there are unneeded files on the disk.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-3-DMA_ERROR_MSG ### Response: (Severity: 3), (Category: L2), (Description: This is a error message in the NPU Driver to indicate DMA operation failed), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_FPOE_DB_CORR_ECC_ERROR_LNK4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast FPOE correctable ECC error on link 4), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-DUMP_INFO_PROBLEM ### Response: (Severity: 7), (Category: OS), (Description: Something went wrong with the dump information storage scheme), (Recommended Action: Collect the following data and contact suppo. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-4-WARNING_CAUGHT_SIGNAL ### Response: (Severity: 4), (Category: SECURITY), (Description: SAM server caught a signal, and terminated), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'route-policy' command in IOS XR L3VPN configuration? ### Response: The 'route-policy' command is used to define routing policies for importing and exporting routes between VRFs and the global routing table. It allows you to filter and manipulate routes based on various criteria such as prefix, community, and AS path. Route policies provide flexibility in controlling the exchange of routing information in an L3VPN. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK_LIB-3-GEN_ERR ### Response: (Severity: 3), (Category: OS), (Description: A generic error occured in the rt_check library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GIRO-4-CFG_RESTORE ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Configuration could not be restored on some interfaces after they were created.), (Recommended Action: Re-enter desired config manually. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-4-DLL_CHECK_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: During the processing of a software change notice, the command to check the list of open dlls vs changed dlls failed. The routine will now attempt to fall back on default disposition.), (Recommended Action: Check the install logs if all the packages are downloaded and install operations completed properly Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that a failure has occured in the CPA interface Shelf Manager), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TYPE6-3-SYSMGR_GET_PROC_ROLE_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: Sysmgr API to get the redundancy related proc role information has Failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTP4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_8_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power greater than or equal to the high Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_MACSEC-6-LATE_PACKET ### Response: (Severity: 6), (Category: OS), (Description: Late packet, where PN < (NXT_PN - Window_Size). Window size will be configured.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-ASSERT_CTX ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal consistency check failed. Dumping runtime context for executing thread. There may be no immediate impact on traffic, but this issue should be addressed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-QCR_PGAR_MAX_MEM_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected QCR PGAR MAX MEM ERR), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the metric-style command in IS-IS? ### Response: The metric-style command is used to configure the type of metric used by IS-IS. The options are narrow (old-style 6-bit metrics), wide (new-style 24-bit or 32-bit metrics), and transition (both metrics during a transition period). Wide metrics provide a larger range of values and are useful in large networks. Narrow metrics are compatible with older implementations. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-6-INFO_SESSION_TERMINATE ### Response: (Severity: 6), (Category: L2), (Description: PPPoE session is terminated for a subscriber.), (Recommended Action: This is an informational message. Action is required only when session terminated due to some errors. Please check for terminate reason, take appropriate action if required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-ARB_SERDES_1_FAIL_1 ### Response: (Severity: 1), (Category: FABRIC), (Description: Arbitration serdes link 1 failure on FIA 1.), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_6_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDPSNMP-3-MEM_ALLOC ### Response: (Severity: 3), (Category: SNMP), (Description: The requested operation could not be performed due to a low memory condition.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKWATCH-6-USER_INFO ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The info about the top users of the specified resource.), (Recommended Action: It is an informational message along with packet depletion log message) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-CHASSIS_TYPE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SOFT_ERROR_ALERT ### Response: (Severity: 1), (Category: FABRIC), (Description: Soft error detected on FIA instance.), (Recommended Action: Please reload the board in the next maintenance window. Until then affected ports will be down. 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-2-LOG_CRIT_OWNER_PLANE ### Response: (Severity: 2), (Category: OS), (Description: A critical owner plane message logged.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSDIR-1-OPERATION_ABORT_PRECHECK_FAIL ### Response: (Severity: 1), (Category: INSTALL), (Description: The Quickstart operation has aborted due to an error when completing prechecks such as resource availability.), (Recommended Action: The reason for this Quickstart operation failure needs to be analyzed. Collect the show tech logs by running 'show tech-support qs' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-3-DMA_ERROR_MSG ### Response: (Severity: 3), (Category: L2), (Description: This is a error message in the PSE Driver to indicate DMA operation failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-6-PCI_BUS_INFO_THRESHOLD_EXCEEDED ### Response: (Severity: 6), (Category: PLATFORM), (Description: A device has been detecting a PCI bus error and it is exceeding threshold. The message has the device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-7-ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: A general failure occured while executing a resource function. The message contains info about the cause of the failure and possibly anticipated actions/effects.), (Recommended Action: Verify continued correct operation of Redundancy Driver.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-3-SYSDB_REG_VERIFY ### Response: (Severity: 3), (Category: IP), (Description: IPv4 Management Agent encountered failure in registering verifier with SysDB. It will recover itself by restarting. Typically this error is caused if sysdb is unavailable for an extended period.), (Recommended Action: If the problem persists get the output of show processes, show sysdb trace, show sysdb trace clientlib job , show ipv4 ma trace location <>, debug sysdb verification job from the location the error message comes from.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-MUTEX ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred in the pthread functions used for thread synchronization. This is most likely a system error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show running-config - show configuration failed - show configuration history last 5 - show commit changes - show process ospf location all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-MAXPFXDISCARDPATH ### Response: (Severity: 5), (Category: ROUTING), (Description: Number of prefixes received from a neighbor for a given address family has exceeded level configured with the 'maximum-prefix' command. The extra path is discarded.), (Recommended Action: Check the prefixes received from the neighbor and verify whether the limit should be increased or the neighbor is sending more prefixes than expected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-PENDING_SEGMENT_FLUSH_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Core dump failed because the pending segment flush failed.), (Recommended Action: Collect the following data and raise DDTS. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_RIB-3-ERR_BATCH_COMPLETE ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered in the call to ipv6_rib_batch_buffer_complete.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBC_MPF-6-INFO ### Response: (Severity: 6), (Category: SERVICES), (Description: The system is in normal state. This is info log.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-3-RN_VPARENT ### Response: (Severity: 3), (Category: MGBL), (Description: An updation operation to an internal data structure failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-7-CONN_PAK_AREA_FAIL ### Response: (Severity: 7), (Category: ROUTING), (Description: CLNS failed to connect to packet subsystem during initialization. As a result, CLNS will not be able to receive or send packets. It's an internal error.), (Recommended Action: Please contact cisco-support with the required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-DEBUG_SPECIFIC_ALLOC ### Response: (Severity: 7), (Category: OS), (Description: This is a debug message that is not compiled into a customer version of the code.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-DBGREG ### Response: (Severity: 3), (Category: ROUTING), (Description: Unable to initialize debugging flags. Debug commands will not function.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-HAL_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A HAL API function has failed in Shelf Manager. The details are supplied in the msg.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-6-QFIFO_DEBUG_NETIO_INIT_FAIL ### Response: (Severity: 6), (Category: QOS), (Description: Debug initialization failed within the qfifo node on the NetIO chain. Debugs may not be printed.), (Recommended Action: Try restarting netio process -get the JID by 'show processes netio location <>' 'process restart location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-FAN_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: The indicated fan has measured RPM below operating level.), (Recommended Action: Verify the failure, give CLI: (admin)# show env --> particularly fan output (admin)# show env trace If the fan failure does not alleviate after 30 minutes, give CLI: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_REX-3-EDM ### Response: (Severity: 3), (Category: SERVICES), (Description: During intialization of the EDM an error occurred. The EDM was not successfully registered, so show commands and other manageability applications may not function correctly. Otherwise the diversion manager will work correctly.), (Recommended Action: This is not a fatal error. If the show commands are required, restarting the REX process should clear up the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-INTERNAL ### Response: (Severity: 3), (Category: MGBL), (Description: The TTY Server has either failed on a function which it expected to succeed, or has got itself into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MXPDRVR-3-NCS1K_LOW_POWER_PROV_SKIP ### Response: (Severity: 3), (Category: PLATFORM), (Description: Port configuration on the specified port failed.), (Recommended Action: The casue for the failure is that the system detected low power situation. This means both the PSU is not having 220V supply, so lower board slices(2,3) should not be used, otherwise it can lead to the node shutdown. If slice 2 or 3 is in provisioned state, please unprovision the slices and power cycle the node once if you want to continue with low power supply or resolve the power fluctuation and re-provision the slices.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-3-MKPDU_ICV_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: Integrity check validation(ICV) failed for the received MKPDU, identified by the given CA(CKN) & RxSCI.), (Recommended Action: For PSK(pre-shared-key) authenticated session, make sure to have, same CAK(key-string)(keychain config for MACSec), configured with valid lifetime for all CA members, for EAP authenticated session, check for the dot1x EAP methods & credentials.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-3-CLI_SPAWN ### Response: (Severity: 3), (Category: MGMT), (Description: This is expected when there is issue with configuration CLI, CLI application is not present at required location), (Recommended Action: The issue should be recovered when retrying login, if this message keeps on coming, then please collect required log) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAP-3-FATAL_ERROR_CCC ### Response: (Severity: 3), (Category: INFRA), (Description: A fata error occurred in CCC communication. Note the reason for the error.), (Recommended Action: Root cause of the error needs to be determined.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_EDM-3-SYSDB_EDM_DATA_GENERATE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The data requested could not be generated.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_MPLS_EA-3-ERR_INFO_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in MPLS EA. Typically, this is an error where the software fails to initialize or programming of forwarding feature fails. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef mpls trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-3-SW_CHANGE ### Response: (Severity: 3), (Category: ROUTING), (Description: The attempt to register with the install manager for change of software notification failed. The process will restart in an attempt to clear the problem. Route policy may not be operational until this is resolved.), (Recommended Action: This error message may be transient. Restart policy_repository and try the use case again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-PATH_ID_OOR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered when allocating path-id for the path.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospf - show ospf trace all - show route ipv4 detail) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-COMMS_RETRY_FAILED ### Response: (Severity: 4), (Category: L2), (Description: A PTP process has failed to send a message and attempts to retry the send have also failed.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-SHIP_PERF_SEND_FAIL ### Response: (Severity: 7), (Category: SYSDB), (Description: Registering performance counter with stats infra failed.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-3-ERR_IMC ### Response: (Severity: 3), (Category: L2), (Description: An internal error encountered during an operation under Multilink Frame Relay(MFR) Management Agent(MA)'s interaction with Interface manager(IM).), (Recommended Action: If observed consistently across each recreate, collect required_info and contact SUPPORT.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-UNREGISTERED_FEATURE ### Response: (Severity: 7), (Category: OS), (Description: The specified feature is not yet registered for OBFL manager.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCI_OS-3-INFO_MSG ### Response: (Severity: 3), (Category: PLATFORM), (Description: Prints important message from the CCI OS library), (Recommended Action: Check the Hardware availability. Also collect dmesg.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_NSF_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MMRP-3-ROUTE_ADD_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: A failure occurred when attempting to create the platform route resource. This route has not been installed.), (Recommended Action: This may be a transient error. The feature will re-attempt route creation, in case the condition is transient. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ether_spa_plugin-6-SPARECOVER ### Response: (Severity: 6), (Category: L2), (Description: An error occurred in the SPA, recovery would be attempted. If recovery succeeds no further messages would be logged and no intervention would be required.), (Recommended Action: If this error continues to occur, move the SPA to a different subslot or to a different slot altogether. If the problem persists, collect the output of 'show hw-mod sub <>/<>/<> counters l2-tcam' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-CPU_PKT_F0_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: IBS from CPU packet FIFO 0 single bit error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-5-SATELLITE_STATUS ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: The satellite has not been discovered on one or more links, or the control session to the satellite has never been established.), (Recommended Action: Run 'show nv satellite status' to display the current status and reason why the satellite is not discovered.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: C_SHIM_PARTNER-3-ECM_INIT_FAILED ### Response: (Severity: 3), (Category: L2), (Description: 'There is a software error when creating ECM connection.'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-CORE_FILE_OPEN_FAILED ### Response: (Severity: 6), (Category: OS), (Description: Could not open a file to dump core. Please configure a valid path.), (Recommended Action: Displayed when a configured path is not accessible. Please configure valid path as exception paths.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_7_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_7 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-5-HELLO_ADJ_CHANGE ### Response: (Severity: 5), (Category: ROUTING), (Description: An LDP hello adjacency has changed state (up/down). If adjancency has went down, then a reason for adjacency going down is also displayed. This message appears only if the mpls ldp log adjacency command is configured.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-6-SYSMGR_PROC_READY ### Response: (Severity: 6), (Category: OS), (Description: An internal error was detected when trying to notify sysmgr that we are ready.), (Recommended Action: Restarting pifibm_server_lc and pifibm_server_rp may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-4-ASSERT ### Response: (Severity: 4), (Category: OS), (Description: Something went wrong in the flow due to which critical assertion failed.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_PLIM_SB-3-SPA_FW_ERR ### Response: (Severity: 3), (Category: L2), (Description: The error message in parentheses is generated by SPA firmware for reason as mentioned in the error message. This error, and the message is logged by the plim holding the SPA.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-UNSUPP_RX_NON_CH ### Response: (Severity: 3), (Category: FABRIC), (Description: The Rx POD detects an unknown error on a pod. The pod might not be functioning properly, and can cause cell drops, or corruption from received cells. There can also be a software bug such that the error is not handled), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-6-GN2412_LINK_DOWN_CLEARED ### Response: (Severity: 6), (Category: PLATFORM), (Description: A link on GN2412 device was down, but now cleared), (Recommended Action: 'show controllers epm-switch port-mapping location *') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlea-3-NATIVE_VLAN_NOTIF ### Response: (Severity: 3), (Category: L2), (Description: The VLAN EA process encountered a problem while trying to send a Native VLAN change notification. Native VLAN support for interfaces on the affected node may not function correctly.), (Recommended Action: Restart the VLAN EA process on the affected node with process restart vlan_ea location (node). If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENV_AGT_DLL-3-MSG_IF_OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Provide the following CLI: (admin)# show env trace loc Wait 1 or 2 minutes) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-4-LOCAL_EID_NO_ROUTE ### Response: (Severity: 4), (Category: IP), (Description: 'There is no RIB route that covers or is a more specific ' 'of the configured local EID database prefix. This means ' 'that the ETR will not be able to forward decapsulated ' 'packets to their destination.'), (Recommended Action: 'Check the network connectivity and routing ' 'configuration within the LISP site and re-establish ' 'a route to destinations covered by the configured ' 'EID prefix.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-4-ERR_CHKPT_INIT ### Response: (Severity: 4), (Category: FABRIC), (Description: Ingressq encountered an error during Checkpoint Init.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-TX_ALARM_OC_SYNC_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: BITS transmitter has detected an open circuit condition.), (Recommended Action: Ensure cable connection between the configured interface port and external equipment.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-6-EA_LTRACE_INIT_FAIL ### Response: (Severity: 6), (Category: QOS), (Description: Ltrace initialization failed within EA. Ltraces may not be printed), (Recommended Action: Try restarting QoS EA process get the JID by 'show processes qos_ea location <>' 'process restart location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of TURBOBOOT in Cisco IOS XR? ### Response: TURBOBOOT is used in Cisco IOS XR for booting the system from a minimal state, often utilized during system recovery or initial software installation to load a specific software image. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SYNC-7-FILE_TOO_SHORT ### Response: (Severity: 7), (Category: OS), (Description: The file is read when it's being written, or version mismatch between the file and the reader.), (Recommended Action: Informational only. Indicates upgraded software accessed older version file before it's updated.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTP8 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZAPDISK-3-INIT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: zapdisk Initialization failed. Process Manager will restart the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-NORTRID ### Response: (Severity: 4), (Category: ROUTING), (Description: OSPF failed while attempting to allocate a router ID from the IP address of one of its interfaces as no suitable IP address was available.), (Recommended Action: Make sure that there is at least one interface that is up and has a valid IP address. If there are multiple OSPF processes running on the router, each requires a unique router ID. You must have enough 'up' interfaces so that each of them can obtain a router ID. It is highly recommended that you configure loopback interfaces or use the router-id configuration command to better control the selection of OSPF router IDs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_CHKPT ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB server encountered an error while updating or accessing its checkpoint information. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_UIDB-2-OPEN ### Response: (Severity: 2), (Category: PLATFORM), (Description: A run time error occurred while initializing the pidb on the linecard. The reason for the error is dispalyed. Please call Cisco Support with the error information), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_SW_HW_INCOMPATIBLE ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-2-ERR_MEM_ALLOC ### Response: (Severity: 2), (Category: ROUTING), (Description: Memory allocation of a critical OSPF resource failed because of a low memory condition. The OSPF process was terminated.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-EYE_SCAN_DONE ### Response: (Severity: 6), (Category: FABRIC), (Description: Fabric driver completed collecting Eye scan dump for the link.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-COMP_ENCODING_SIZE_TOO_BIG ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: ACL compress yields an encoding size greater than 32 which cannot be accommodated.), (Recommended Action: Revise the ACL's object groups to yield encoding size less than or equal to 32 bits for IP prefix fields or 16 bits for SRC port field.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL-3-GENERIC_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: A software error has occurred in ipv6/rpl code.), (Recommended Action: Try restarting the rpl ma process using the 'process restart ipv6_rpl_ma' cli. If problem persists contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_FIB-3-INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message in the SSE FIB to indicate that an error was seen during init operation. A return code is returned to PI which can do a retry or exit based on if error persists.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-AAA_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: Failed to execute a AAA function.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_SYSMGR_REGISTER ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: S2681-3-SCHEDPOLICY_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The S2681 UART driver was unable to set the scheduling policy for the interrupt handler.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_CLI-3-INTERNAL ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP CLI Agent has encountered an invalid state - this point in the code should not have been reached. The HTTP process may need restarting if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-CPU_PERR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter driver detected a parity error from the CPU), (Recommended Action: The error message indicates bad connection on CPU address/data bus, the card should be replaced if the error message persists after a few reloads of the card by either 'hw-module location <> reload' or OIR of the card. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-3-RECEIVE_OAMPDU_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The Ethernet Link OAM Daemon was unable to receive an OAMPDU successfully from SPIO. This could be due to the OAMPDU not being received properly or being corrupt such that the OAMPDU can't be properly processed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the default behavior of the running configuration in IOS XR? ### Response: By default, the running configuration in IOS XR is not saved automatically. Changes made to the running configuration are lost on a reload unless explicitly saved to a file using the 'save configuration' command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-6-MKPDU_ICV_SUCCESS ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-2-THREAD_INIT ### Response: (Severity: 2), (Category: ROUTING), (Description: FIB thread-specific initialization has failed due to the reason indicated in the message. The process will attempt to recovery by restarting. If the restart count is excessive then the node may reload. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_TXM-3-ENS_INIT ### Response: (Severity: 3), (Category: QOS), (Description: The QOS TXM hit an error condition when registering with ens. Due to this failure LOCP feature may not work. This failure occurs in one of the following conditions: 1. Failed to get the event manager of the netio control thread 2. Failed to initialize ENS subsystem in LR-scope. 3. Failed to create new nrs class/data handle. 4. Failure during ens/nrs registration.), (Recommended Action: Collect logging info after enabling qos data txm debugs. Also collect the information specified under the component required_info and call your Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-6-TRAP_QFULL ### Response: (Severity: 6), (Category: SNMP), (Description: SNMP traps for the host is dropped due to trap queue full condition.), (Recommended Action: 1) Check whether trap delay timer is configured and if required increase queue size 2) Check 'show snmp trap details' for details on trap being dropped and analyze if there is a burst of traps generated by any mib.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_0_CONST_BP_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: NPU-0 is constantly backpressuring bridge instance-0.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NCS4K_4H_OPW_QC2-3-MDIO_INVALID_MEMORY ### Response: (Severity: 3), (Category: PLATFORM), (Description: MDIO Invalid Memory), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_CFG-2-IPV4_SCALE_INTERNETOPT_UNSUPPORTED ### Response: (Severity: 2), (Category: FABRIC), (Description: The fia config (fia_cfg) has found pre-existing IPv4 Scale Internet-Optimized config. [hw-module fib ipv4 scale internet-optimized]. This feature is not supported anymore and therefore ignored. Please delete this config before upgrading to next release.), (Recommended Action: Remove the ipv4 scale internet-optimized configuration If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBUS-7-API_DOWNLOAD_FAIL_STATUS ### Response: (Severity: 7), (Category: PLATFORM), (Description: mbus debug info %s - a string containing the slot number.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-MAC_ADDRESS_INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The CE-TFTP server process exited because was not able to intitialize the local mac address.The process will respwan itself.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-IF_OIR_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The swappable interface on the network processor failed the OIR event.), (Recommended Action: Retry the OIR action for the swappable interface. If this condition persists, the line card should be reset.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMS-7-LOCKING ### Response: (Severity: 7), (Category: SYSDB), (Description: The SysDB server has either failed to acquire or release a lock.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_PAK_CLIENT_CONN ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-4-EXIT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The specified process failed to notify the system manager that it was exiting. In very rare cases, this could result in the process not being restarted when it ought to be.), (Recommended Action: If the process in not running and it ought to be (ie, there is PIRD configuration remaining), then remove all PIRD configuration, commit this change, then re-apply the configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-MAC_0_RX_FRAME_ERR_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: MAC on NPU-0 received an errored frame interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_SYSDB_REG_VERIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPDB-7-INTERNAL ### Response: (Severity: 7), (Category: SYSDB), (Description: The client library has either failed a function that expected to succeed, or has got into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-6-PLUGIN ### Response: (Severity: 6), (Category: L2), (Description: This is just an informational message), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSEC-4-WARNING ### Response: (Severity: 4), (Category: SECURITY), (Description: IPSec Base component warning message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MOFRR_FLOW-3-DETECT_LOSS_PRIM ### Response: (Severity: 3), (Category: ROUTING), (Description: LC control plane detected that either no traffic coming or traffic loss is occurred on primary path. Data plane should switch over to the MoFRR backup path already. But somehow the traffic switchover notification message sent from data plane has been lost from NP on the way to LC CPU. With this detection, control plane will re-sync with data plane on MoFRR route.), (Recommended Action: It is a self-recovery detection. There is no extra action needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-3-ETH_SERVER_BUFF_FREE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to free the buff for eth_server. %s- Reason for not being able to free the buffer.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-4-WRONG_IDPROM_CONTENT ### Response: (Severity: 4), (Category: DRIVER), (Description: Card manager has detected that there is incorrect content in the IDPROM of indicated module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POS-4-PORT_ENABLE ### Response: (Severity: 4), (Category: L2), (Description: An error occurred when attempting to enable a SONET/POS port.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-4-MUTEX_MON ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: SPP or one of its clients was unable to register to monitor a shared memory mutex. This indicates that either system resources are low, or that there is an internal problem with SPP or the shared memory infrastructure. Restarting SPP or its client processes may result in memory leaks.), (Recommended Action: Wait until any situation which is putting stress on system resources is resolved, and then try the requested action again. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LSLIB-3-INT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred as indicated in the message.), (Recommended Action: Collect show tech-support and other debug information for the specific client process as well as LSLIB traces and system logs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-CHKPT_RESTORE_CLASS ### Response: (Severity: 3), (Category: OS), (Description: nrs_chm_chkpt_create_class failed while restoring the class handles from the chkpt shared memory after nrs server process restarts.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-INVENTORY_FIELD_IS_NULL ### Response: (Severity: 3), (Category: MGBL), (Description: Error in extracting rack/slot/module name from sysdb path.), (Recommended Action: Restart parser_server process (process restart parser_server). If the message recurs, copy and save the message and call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-IM_CONN_TO_COID_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed to retrieve a connection ID from the IMD connection context. This may be due to a low-memory condition.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the IS-IS process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-6-LATCHING_SESSION_STARTED ### Response: (Severity: 6), (Category: L2), (Description: A latching loopback session has successfully started. This is for informational purposes only.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEV2-3-SVC_ERROR ### Response: (Severity: 3), (Category: OS), (Description: A service API failed and error is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-INTF_REMOTE_DYING_GASP ### Response: (Severity: 6), (Category: L2), (Description: The remote peer has indicated a dying gasp. This means that the remote peer is coming down.), (Recommended Action: Restart the remote peer.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-EVQ_SIZE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occurred while retrieving the size of the specified queue. As a result IS-IS's internal state may be inconsistent. This indicates an internal software programming error.), (Recommended Action: Consider restarting the IS-IS process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_TOPAZ-7-ERR_FSM_STATE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an unexpected/invalid state while trying to process an event for a client request. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-POLICY_INTERFACE_REGISTER_FAILED ### Response: (Severity: 3), (Category: L2), (Description: CFM encountered an error while trying to register for notifications for interfaces in configured Bandwidth Notifications policies. This situation could indicate an issue with the interface names in the configured policies, or that system resources are low. The operational state of CFM will now be out-of-sync with policy configuration as some interfaces cannot be resolved.), (Recommended Action: Examine configured policies and check for invalid interface names. Otherwise restarting the CFM Daemon on the node where the problem has occurred may help to resynchronize the system state. 'process restart cfmd location ' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you verify the software installation on Cisco IOS XR? ### Response: To verify software installation on Cisco IOS XR, the 'show install active' command can be used to display the currently active software packages on the router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-INVALID_NOTIFICATION ### Response: (Severity: 3), (Category: MGBL), (Description: 'nvgen_server got an invalid notification form ovl process'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-3-AUTO_RELOAD_FAILURE_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Auto reload of the LC after auto fpd upgrade is not initiated, as errors are seen during FPD upgrade.), (Recommended Action: If this warning is seen, try to check for other FPD error messages and resolve the errors (by manually updating the FPD) and reload the Line Card if required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD-2-MEM_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: This is an error message from FPD operation. It indicates error condition was encountered in FPD operation.), (Recommended Action: Clean the harddiska: folder) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-NODE_UNDERGOING_FPD_UPGRADE ### Response: (Severity: 6), (Category: INFRA), (Description: Automatic FPD upgrade is occurring on the node. This may cause the node to take longer than usual to boot after apply by reload. The node timeout has been extended to 15 minutes. If, after this time, the node has not booted correctly and not set up the required communication path, then the operation will be failed on this node.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-LWA_REM_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to remove a username from the LWA DB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-FIFO_0_OFLOW_FIA2BR_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: FIFO-0 FIA to bridge instance-1 overflow.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-APP_INTF ### Response: (Severity: 3), (Category: SERVICES), (Description: ServiceApp interface cannot be moved from one cgn instance to another without first removing it from the latter.), (Recommended Action: This is a serious error and cgn_ma process has to be restarted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-MEM ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates that an error has occurred during memory allocation. This error is due to insufficient memory available in the system.), (Recommended Action: Please contact Cisco TAC and provide this message text as well as the information specified in required_info section.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-BAD_VSA_VENDOR ### Response: (Severity: 3), (Category: SECURITY), (Description: Vendor specified for the VSA is not recognized according to table bitmap. An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SE_P2MP_SRVR-3-INIT_CRITICAL_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A critical error occured during the initialization of SE P2MP_SRVR process which involves exiting the process. The SE P2MP_SRVR will restart and unless the same error occurs on the next attempt the SE P2MP_SRVR will function normally. If the error is persistent, it indicates the system error or HW error which needs further investigation. The cause of the error will be mentioned in the message displayed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-3-ECM_SETRETRY_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Failed to set linear connection retry mechanism in Port Arbitrator Client), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-INVALID_NETLINK_PAYLOAD ### Response: (Severity: 4), (Category: INFRA), (Description: The Netlink module received an invalid Netlink message from the kernel. This could mean that XR and Linux state synchronized by the process may be out of sync.), (Recommended Action: Examine XR and Linux states for interfaces whose configuration is being mirrored by the process. If they are out of sync, restart the process. If the problem persists, Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-KEY_NOT_FOUND_IN_PROFILE ### Response: (Severity: 3), (Category: SECURITY), (Description: In Main Mode, The ID payloads are exchanged only in MM5 and MM6. Since keyring material is needed in earlier stages of the negotiation, it is looked up based on peer address. This error is seen when the selected keyring appears to not match the keyring configured under the ISAKMP profile for that peer.'), (Recommended Action: 'Make sure that the keyring in which the key exist is attached to the ISAKMP profile') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-SYSDB_COMMIT ### Response: (Severity: 7), (Category: INSTALL), (Description: The current operation could not complete the transaction of items which are needed to activate it.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELOGM-4-EXITING ### Response: (Severity: 4), (Category: L2), (Description: The process failed to process incoming events, and will exit. It should be restarted by System Manager and resynchronize its internal state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-3-RP_REDUNDANCY_INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: A software error occurred when the ANCP process tried to initialize the redundancy data with its standby RP/DRP), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and if ANCP process is able to initialize and come up successfully after restart, then there is no need to take any action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKWATCH-6-INFO_HEAD ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The header for resource depletion information that follows this message. It is of the format: PROCESS_NAME PID COUNT), (Recommended Action: It is an informational message along with packet depletion log message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-AD9554_DEVICE_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: AD9554 device failure/success.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: attestation_agent-6-IMA_UNEXPECTED_BLOCK_FOUND ### Response: (Severity: 6), (Category: MGBL), (Description: Kernel IMA data was not freed as expected.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HBAGENT-6-NODE_RELOAD ### Response: (Severity: 6), (Category: PLATFORM), (Description: Message indicating that the node has received a reload notification and the node is going to reload soon.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE_ERR_7_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE_ERR_7 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-4-ERR_LTRACE_INIT ### Response: (Severity: 4), (Category: FABRIC), (Description: The Fabric driver could not open/initialize the ltrace buffer. The Fabric driver and the system should still function as normal, with the exception that ltrace will not be available for sfe_drvr process.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PVSTAG-4-RECEIVE_FAIL ### Response: (Severity: 4), (Category: L2), (Description: A failure has repeatedly occurred when attempting to register to receive PVST+ or PVRST BPDUs, and either the retry timer could not be allocated or the maximum number of retries has been reached. No BPDUs will be received on the affected sub-interfaces, and hence the MAC table will not be flushed when a topology change occurs. This could result in traffic being forwarded incorrectly or dropped for a period of time, until the MAC entries time out or are relearned.), (Recommended Action: It may be possible to recover by restarting the pvstag-io process on the affected line card, useing the 'process restart' command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSELIB-4-EXIT_ON_ERR ### Response: (Severity: 4), (Category: L2), (Description: An error occurred in the PSE ASIC client library after which the client code cannot continue. This error is encountered when a client module (e.g. cli command) has difficulty retrieving information from the PSE driver. The root cause may be located in either hardware or software.), (Recommended Action: *RECUR* Copy the error message exactly as it appears on the console) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-4-ERR_THREAD_MUTEX_LOCK ### Response: (Severity: 4), (Category: FABRIC), (Description: FSDB encountered an error while locking a mutex to access the specified shared resource. The operation related to the resource may be affected while the process continues to run normally.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FTI-6-POOL_HEALTH ### Response: (Severity: 6), (Category: INFRA), (Description: Opflex pool health change), (Recommended Action: This message is for information purpose only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-HW_MODULE_PROFILE_PFC_NEED_RELOAD ### Response: (Severity: 3), (Category: FABRIC), (Description: If a traffic-class is added or removed from the config, there will be inconsistency between the user config and the hardware. Needs attention with line card reload.), (Recommended Action: System LC is inconsistent. Need to reload the line card for new values to take effect. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPMIB-3-BAG_FAILED ### Response: (Severity: 3), (Category: SNMP), (Description: A problem occurred while encoding or decoding information from a bag.), (Recommended Action: If the error repeats, copry the error message as it appears and report it to technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-SHIP_REGISTER_FAIL ### Response: (Severity: 7), (Category: SYSDB), (Description: Registering with stats infra failed.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_OC768-7-DEBUG_MSG ### Response: (Severity: 7), (Category: L2), (Description: This is a debug message in the plim_oc768 driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PM_TEST-6-UPDATE_ERR2 ### Response: (Severity: 6), (Category: PLATFORM), (Description: hfr_pm_test encountered an error and is not able to recover from the error. A reason text will be supplied call support with this text. An integer errno will also be printed.), (Recommended Action: This is just test software which the customer does not get.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-PCI_RAM_CORRECTABLE_ERROR_MASK ### Response: (Severity: 3), (Category: PLATFORM), (Description: Indicates a correctable single-bit error occurred on this internal SRAM. This memory is considered 'persistent' and requires special handling as described in the 'Data_corrected' row of Table 1.2. %s - name of ram that sbe occurred %x - key of error node recorded %s - error data), (Recommended Action: Ignore this unless it comes with other error message) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-4-WD_EXPIRED ### Response: (Severity: 4), (Category: PLATFORM), (Description: Failed to punch the watchdog timer within one second.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-1-CPU_HOG_5 ### Response: (Severity: 1), (Category: HA), (Description: This message is displayed), (Recommended Action: The command 'show watchdog trace' will display additional information about the potential CPU hog. If the hog is persistant, contact technical support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKEND-7-INTERNAL ### Response: (Severity: 7), (Category: SYSDB), (Description: The backend library has either failed a function that expected to succeed, or has got into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-SHM_ENTRY_ALLOC_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: An attempt to allocate entry in shared memory region failed.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_0_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'redistribute' command in OSPF? ### Response: The 'redistribute' command is used to inject routes from one routing protocol into another. In the context of OSPF, it is used under the OSPF process to redistribute routes from other protocols (connected, static, ISIS, EIGRP, BGP, etc.) into the OSPF routing table. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-INPUT_SIGNAL_ERROR ### Response: (Severity: 1), (Category: FABRIC), (Description: Input signal to the device doesn't match expected value.), (Recommended Action: Please reload the board in the next maintenance window. If this fault happens on a single FIA/slice on LC and the fault could not be cleared after card OIR, please RMA the card. 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INVMGR-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates memory allocation failure. Inventory information for the specified slot would be incomplete. This would affect information provided to CLI 'show inventory', inventory schema, and the entity related MIBs for the specified slot. %s indicates the internal data structure that failed allocation for.), (Recommended Action: Reduce other system activity to ease memory demands and restart process invmgr via CLI 'process restart invmgr' to recover. If conditions warrant and minimum memory requirements not met, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_CLIENT_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver subsystem initialization error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-2-UNKNOWN_PLATFORM ### Response: (Severity: 2), (Category: PKT_INFRA), (Description: platform_get_type returned an unknown platform type.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-I2C_FAILURE_HANG ### Response: (Severity: 3), (Category: PLATFORM), (Description: An I2C bus hang was encountered when attempting to access a sensor.), (Recommended Action: Try doing restarts of below process admin process restart envmon loc <>. admin process restart i2c_server loc <>. Location is from the node on which this ios_msg is seen. If the issue still persists collect required_info) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_3_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Rx power greater than or equal to the high Rx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Rx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-2-DRAM_INIT_FAILURE ### Response: (Severity: 2), (Category: L2), (Description: The NPU driver was unable to initalize DRAM. and must trigger a node bringdown to effect recovery.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-3-TTY_NOT_REGISTERED ### Response: (Severity: 3), (Category: MGBL), (Description: The RS232 DLL tried to perform an operation on a TTY that isn't registered with the TTY Server.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC_CTRL-3-RACK_MISMATCH_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The rack number in rommon does not match the rack number in admin config. Fixing the rommon rack number to that in admin config. This will cause a reload of the system.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: T3E3-4-FEAC ### Response: (Severity: 4), (Category: L2), (Description: New Far End Alarm Code received.), (Recommended Action: No action required) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-3-NO_CONSOLE_TUNNELING ### Response: (Severity: 3), (Category: PLATFORM), (Description: There is a hardware issue and MCU is not accepting configuration which prevents the support of console tunneling feature.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_5_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_5 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-5-UNABLE_TO_MOUNT ### Response: (Severity: 5), (Category: PLATFORM), (Description: Check for partitions and mount Satori internal eUSB. This notice message will gets printed when it unable to mount Satori internal eUSB.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_TABLE_REF_COUNT ### Response: (Severity: 3), (Category: OS), (Description: Any table has to be part of the subgroup 0.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCAM_MGR-2-INIT_INTERNAL_DATA ### Response: (Severity: 2), (Category: PKT_INFRA), (Description: 'Typically this indicates an error condition, ' 'such as tcam mgr crashes while internal dats are updated. ' 'and leave the internal data in an inconsistent state ' 'To recover from the error, ' 'TCAM Manager has to reset its internal data.'), (Recommended Action: 'Please monitor the linecard ' 'and reload the linecard if necessary. ' 'hw-module location <> reload ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-TRANSACTION_NOT_COMMITTED ### Response: (Severity: 6), (Category: INFRA), (Description: There is a currently a transaction in progress, and changes have been applied. At this stage, the active software is different to the fallback software. If the system reboots before the transaction is committed, the fallback software will be used.), (Recommended Action: Use 'install commit' to commit the transaction.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_OC3_OC12-3-LTRACE_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: SPA process encountered an error during software initialization. ltrace initialization is failed. So we will not get any traces using ltrace cli. It may fail very rarely. It will work most of the time. We added this message only for debugging purpose.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLICE_MGR-3-INIT_FAILURE ### Response: (Severity: 3), (Category: LIBRARY), (Description: SLICE_MGR Library Initialization failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-4-LOCAL_CORE_ISOLATION_CLEAR ### Response: (Severity: 4), (Category: L2), (Description: ICCP-SM has recovered from local core isolation and has attempted to recover the ports in the redundancy group.), (Recommended Action: This message may not require any action. However the show l2vpn iccp-sm group group-num command may be used to verify the state of the ICCP-SM core interfaces. Reference the L2VPN P_MCLAG section of the IOS XR documentation for details on core isolation failures and related configuration commands.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ENDCOPTIONMISSINGCOMMA ### Response: (Severity: 3), (Category: MGBL), (Description: 'end option mark is missing a comma in the command. The calling function the coption id and the command are are displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-USER_RESET ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that the node will be reset because user has requested to reload the node.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show l2vpn forwarding bridge-domain' command in IOS XR? ### Response: The 'show l2vpn forwarding bridge-domain' command is used to display the L2VPN forwarding information for bridge domains. It shows the bridge domain name, the outgoing interface or pseudowire, the next hop, and the MPLS label used for forwarding. This command is useful for verifying the L2VPN forwarding plane. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-6-NODE_PWRCYL ### Response: (Severity: 6), (Category: PLATFORM), (Description: Message indicating that the node has received a power down request and the node is going to power down.), (Recommended Action: No action is required. The message is logged for informational use.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-7-INTERNAL ### Response: (Severity: 7), (Category: MGBL), (Description: An unexpected internal error occurred in the configuration subsystem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPMC_GTRIE_DEBUG-6-TERM_ERR ### Response: (Severity: 6), (Category: ROUTING), (Description: Internal non-serious error. GTRIE debug library termination failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_1_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2SNOOP-3-NO_MEM ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the L2SNOOP process try to request more memory. The requested operation by l2snoop could not be accomplished because of a low memory condition.), (Recommended Action: In the problem recurs, reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TP_ALARM-4-LOCKOUT ### Response: (Severity: 4), (Category: ROUTING), (Description: The indicated LSP has entered or exited lockout state due to administrative action at one endpoint.), (Recommended Action: If the state change is unexpected, confirm the local configurations as well those LSRs on the path of the LSPs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-2-FAB_LICENSE_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature is enabled without having valid license. This feature is per RSP3-Lite based, so in a HA setup 2 licenses required. In stand alone setup 1 license is enough. Use 'admin show license' CLI to check license status.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-3-MALLOC_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: BFM encountered an memory allocation error), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON_MA-7-INIT ### Response: (Severity: 7), (Category: QOS), (Description: The Afmon MA process encountered the specified error while initializing the specified facility. If this error occurs, the sysmgr process will restart the Afmon MA process.), (Recommended Action: Wait until sysmgr process restarts the Afmon MA process. If problem still occurs, please collect 'show tech-support performance-traffic' and contact Cisco technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-NODEID_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cctl_primary_server process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show cctl_primary_server location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REBOOT_LIB-6-REBOOT_INITIATED ### Response: (Severity: 6), (Category: INFRA), (Description: Informational message that reboot library initiated reboot), (Recommended Action: None No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_AHS_LOS_LANE0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-PCIE_CORE_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: CIB PCIe core error overrun), (Recommended Action: Reset the board) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-3-OPERATION_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The update operation for the specified FPD has failed.), (Recommended Action: Retry the operation to update the image. If the retry operation fails, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-1-RX_BRST_MAX_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered interlaken Rx burst max exceeded error.), (Recommended Action: This fault would result in traffic loss. Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_OUT_MEM_UCORR_ECC_ERROR_LNK4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast output memory uncorrectable ECC error on link 4), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SERVER-7-ERR_ATTR_INIT ### Response: (Severity: 7), (Category: OS), (Description: Failed to init pthread attr.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_XRV9K-4-ERR_CERR_REG ### Response: (Severity: 4), (Category: L2), (Description: BFD PLAT was unable to register to component error message services. This is probably due to a faulty installation.), (Recommended Action: Make sure the libplatform_bfd_cerror.dll is present in lib/cerrno. If the DLL is present, the process must be restarted before it can function correctly. If the DLL is not present, then the problem is with image installation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-EVM_RETRY ### Response: (Severity: 3), (Category: ROUTING), (Description: A call to the external event manager to set connection retry values failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-ACTION_FAILURE_DETAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code and a string interpretation of the error code. It also provides a more verbose information. Here is a list of possible reasons for this message (not all-inclusive). - Failed to alloc vclabel stats. This condition indicates a problem with the software on the card. Typically, this occurs when the software failed to alloc vclabel stats.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef trace location <> show cef platform trace all location <> show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-UNRESOLVED_HOOKPOINT ### Response: (Severity: 3), (Category: MGBL), (Description: 'Unresolved hookpoint'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_ATOM-4-INTERNAL_ERROR ### Response: (Severity: 4), (Category: PLATFORM), (Description: L2FIB entered into an invalid state because of incorrect sequence), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-PKTDROP ### Response: (Severity: 3), (Category: ROUTING), (Description: An input packet was dropped for the specified reason.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-4-TO_MRIB_MDT_UPDATE ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSDIR-1-OPERATION_PROC_ABORT_REQUEST ### Response: (Severity: 1), (Category: INSTALL), (Description: Quickstart operation aborted due to the named process requesting an abort on the given node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The reason for this qs operation failure has to be analyzed. Collect 'show tech-support qs' and forward the logs to the TAC. In addition, 'show tech-support' should be gathered for the process which requested the abort where possible. These logs should also be forwarded to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-6-OPERATION_SUCCESS ### Response: (Severity: 6), (Category: PLATFORM), (Description: The particular operation mentioned in the message succeeded.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-SESSION_SECURED ### Response: (Severity: 5), (Category: L2), (Description: MKA was able to secure the MKA Session identified by the interface and CKN given with the peer identified by the RxSCI given. SESSION_SECURED happens successful only after MACsec Secure Channels and Secure Associations have been installed and enabled for both Rx and Tx.), (Recommended Action: No action required (normal operation).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-4-BD_BVI_VMAC ### Response: (Severity: 4), (Category: L2), (Description: The HSRP or VRRP MAC conflicts with that of another interface in the bridge-domain.), (Recommended Action: Reconfigure the HSRP or VRRP MAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_THRESHOLD ### Response: (Severity: 1), (Category: PLATFORM), (Description: ASIC errors have exceed the threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_LQ_PKT_LEN_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue packet length error on XAUI 1 LQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-3-LOCK_FAILED ### Response: (Severity: 3), (Category: IP), (Description: Internal error during locking of TCP resource.), (Recommended Action: Please try restarting the process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-INVALID_LEAP_SECONDS_CONFIG ### Response: (Severity: 4), (Category: L2), (Description: At least one of the leap seconds configuration items implies a leap second event that will result in the UTC offset changing by more than one second. This is an invalid change since the final minute of each day may only contain 59, 60 or 61 seconds.), (Recommended Action: This error suggests a misconfiguration. If using leap second offset configuration, adjust the configuration such that the UTC offset will only change by one second. If using leap second file configuration, check the file for consecutive entries which differ by more than one second.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY_CONNECT-3-LOCKING ### Response: (Severity: 3), (Category: MGBL), (Description: The TTY Connection library encountered an unexpected error occurred acquiring a lock.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-TARGET_CFG_UNLOCKERR ### Response: (Severity: 3), (Category: MGBL), (Description: Config process failed to release exclusive lock held by this session.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTR2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD_NETIO_DLL-3-EGRESSQ_CREATE_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: FWD was not able to create one of the egressq queues.), (Recommended Action: No Action required Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-1-ERR_HW_DLL ### Response: (Severity: 1), (Category: FABRIC), (Description: Fabricq encountered an internal hardware dll api error. These type of errors are usually generated from CAI APIs. Below gives an example of where these type of error could be coming from: 1) iLite link errors 2) cci device discovery errors 3) gaspp driver init 4) cdma api errors 5) udma api errors 6) bist api errors), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-PULSE_FAILED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The SockIO SPP plug-in receive thread failed to communicate to the main thread and terminated. No more data will be read from the ports), (Recommended Action: If any problems are seen, they may be rectified by restarting the spp process using the 'process restart spp' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: METRO_STATS_API-7-RESERVE_LMT_MSG ### Response: (Severity: 7), (Category: L2), (Description: This is a debug message in the Hardware Stats Manager Library to indicate the stats reserve limit is reached. In most cases these messages will stop once the temporary condition is resolved. Examples of when this error occurs are: 1. The client tries more counters than that are free for that type), (Recommended Action: No action is required. These are Debug messages. An error was returned by Stats Manager APIs to applications. Applications receiving this error will report the error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_OUT_MEM_UCORR_ECC_ERROR_LNK4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast output memory uncorrectable ECC error on link 4), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-INSTALL_OPERATION_SYSTEM_ERROR_GLOBAL_NODES ### Response: (Severity: 3), (Category: INSTALL), (Description: A system error occurred during an install operation. This may indicate a transitive problem within the system, a problem with the code or a user error not verified by the install system.), (Recommended Action: Check system consistency using 'install verify'. Run 'install verify packages repair' if anomalies are found. Reattempt the install operation. If the problem persists collect diagnostic information about the failure using the specific command and pass it to your TAC representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ-3-ERR_EVM_FAIL ### Response: (Severity: 3), (Category: L2), (Description: An internal error was detected when trying to create EVM connection. It can fail during following scenarios: 1) EDM registration/connect/notify. 2) BAG's rule registration failed.), (Recommended Action: No action is required. The process retries automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_SYSDB_BAG_DECODE ### Response: (Severity: 3), (Category: ROUTING), (Description: A Bag related error occurred.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the Cisco IOS XR Zero Touch Provisioning (ZTP) feature in network deployment and monitoring? ### Response: The Cisco IOS XR Zero Touch Provisioning (ZTP) feature allows automating the deployment and configuration of Cisco IOS XR devices. It enables the device to download its initial configuration from a remote server without manual intervention, which simplifies the network deployment and reduces the chances of configuration errors. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBUS-4-SVC_ZERO_LEN_PKT ### Response: (Severity: 4), (Category: PLATFORM), (Description: mbus debug information %d - mbus message type. %d - slot where packet originated), (Recommended Action: we can safely ignore this message if it is seen once.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-1-RX_SOP_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered interlaken Rx missing SOP error.), (Recommended Action: This fault would result in traffic loss. Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-COPTIONNOTPRESENT ### Response: (Severity: 3), (Category: MGBL), (Description: 'Coption is missing in the command. The calling function and the command are displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EASYDEBUG-2-GEN_ERR ### Response: (Severity: 2), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-KDUMP_START ### Response: (Severity: 3), (Category: PLATFORM), (Description: OS running on the indicated card is reporting kdump has started.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-4-ATTACH_RECONNECT_HANDLER ### Response: (Severity: 4), (Category: PLATFORM), (Description: Failed to attach a reconnect handler to ethernet server. If the ethernet server restarts, heartbeat agent may not be able to receive/write messages, which could eventually lead to this node being reset by the RSP heartbeat monitoring code.), (Recommended Action: If the issue results in any adverse system behavior please contact your Cisco technical support team after collecting the following information: 1. The console output of the active RSP from user login till the end. Please make sure the above error message(s) are included. 2. (admin)#show install trace mbi-hello location 3. The output of the following CLI commands:) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-MISSFILTER ### Response: (Severity: 4), (Category: MGBL), (Description: The command entered requires a filter name and one was not supplied.), (Recommended Action: Use the help command to determine the correct usage for this command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-NO_CHANGES_MADE ### Response: (Severity: 6), (Category: INFRA), (Description: The requested install action resulted in no action being taken on any packages. This may be expected if the specified packages are already at the appropriate version (for example, a package is already installed at the highest version available before an upgrade operation). Alternatively, it may indicate an error in the specified operation parameters. Examples include (but are not limited to) a typographical error when requesting the install action, for example removing a non-existent package, or incorrect repository configuration.), (Recommended Action: Check the requested install action is what you intended it to be, and if so, check that any repositories you may be using are configured correctly and are accessible. If carrying out a package upgrade, for instance, check that the desired package is available at a higher version via show install available all. If carrying out a package remove, check that the intended package is active via show install active all.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_APS-7-NOMEM ### Response: (Severity: 7), (Category: L2), (Description: The process is out of memory.), (Recommended Action: Check process list for source of memory loss. Check if h/w memory requirements are met.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RAW-3-DEBUG_INIT ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the RAW process try to do debug related initialization.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-FILE_NOT_IN_LOADPATH ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the installation is corrupt, or the Package infrastructure is behaving incorrectly. An expected file was not found in the package directories, so processing of the operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_QOSEA-3-DATABASE_RESET_FAILURE ### Response: (Severity: 3), (Category: QOS), (Description: After a modify rollback failure, QoS EA will attempt to reset its database, but this reset attempt failed. The database for the said interface might be in an unknown state. Neither the old policy nor the new policy is applied in hardware for this interface.), (Recommended Action: Try removing the QoS policy on the interface for which this error message is printed from configuration, and then reattach the policy to the interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-4-CONN_RETRY ### Response: (Severity: 4), (Category: HA), (Description: RMF failed to establish a connection to RMF on the another card.), (Recommended Action: If condition is reported multiple times, collect show redundancy trace location all, show redundancy, and show logging output and contact customer service.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-EBS_CPP_DATA_MBE ### Response: (Severity: 1), (Category: PLATFORM), (Description: EBS to CPP packet data multiple bits error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-ELMI_UPDATE_FAILED ### Response: (Severity: 4), (Category: L2), (Description: A failure occured when attempting to update E-LMI. This event was triggered by either a change within the network (e.g. a remote MEP going missing), a change to local MEP or cross-check configuration or E-LMI starting up and requesting information. The result is that E-LMI will not have the most up to date information to report to the CE device.), (Recommended Action: To trigger a replay of information between E-LMI and CFM, try restarting the CFM Daemon using the 'process restart' command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VLAN_EA-3-MAX_VRRP ### Response: (Severity: 3), (Category: PLATFORM), (Description: Configuration failed because the maximum number of VRIDs which can be programmed has exceeded.), (Recommended Action: Please capture the complete error log. Please check the data sheet for the supported configuration. Please contact TAC for any support on this) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-FIA2NPU_0_PKT_MINLEN_ERR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet minimum length error on FIA to NPU-0 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-4-BADCOUNT ### Response: (Severity: 4), (Category: ROUTING), (Description: The actual number of paths for a prefix is less than the successor count. The problem may resolve itself the next time any event like packet reception occurs for that prefix. To see if the problem is resolved or not, check the number of successors in EIGRP topology output of that prefix.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-UNSUPPORT ### Response: (Severity: 3), (Category: L2), (Description: Unsupported CPP TYPE.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-7-ERR_MEM_ALLOC ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failure in Inventory Manager memory allocation error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PVSTAG-4-INIT_FAIL ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the process. This resulted in the restart of the process.), (Recommended Action: The process will automatically exit and will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-AUTO_ABORT_TIMER_EXPIRED ### Response: (Severity: 2), (Category: INSTALL), (Description: The auto-abort timer has expired, reloading the router/SDR.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIO-7-ERR_ECM ### Response: (Severity: 7), (Category: PLATFORM), (Description: The EIO Library encountered ECM error, therefore failed to send pulse. The System Manager process (sysmgr) will automatically respawn the annunciated process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRMS-3-OUT_OF_MEM_ERR ### Response: (Severity: 3), (Category: L2), (Description: SRMS is out of memory. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Restart SRMS process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS VPN central services feature? ### Response: The MPLS VPN central services feature allows MPLS VPN providers to offer centralized services, such as Internet access, to VPN customers. It enables traffic from VPN sites to be routed to a central site for services before reaching its final destination. Central services VPNs are implemented using route targets and BGP route importation at the central services PE router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_MGR-7-ERR_EVM_NOTIFY ### Response: (Severity: 7), (Category: FABRIC), (Description: CCSQ Event Manager notify error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL_ENS-7-OPERATION_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_UNQUAL_OPTIC ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when an CISCO unsupported optic is inserted any of the satellites ports.), (Recommended Action: Please use CISCO supported optics.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-HEARTBEAT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Heartbeat failure notification from NPUS was received by the Services PLIM driver or a critical error occured in the thread monitoring heartbeat from NPUS.), (Recommended Action: Do warm reload of the Services PLIM MSC. If the issue persists do a cold reboot of the same. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_SOCKET-2-MSG_ERR_GET ### Response: (Severity: 2), (Category: L2), (Description: A very rare event where a message read was errored. The error should not be persistent.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Collect the required_info, if the message persists across multiple recreates.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC_CTRL-6-CONTROL_LINK_FAILURE ### Response: (Severity: 6), (Category: PLATFORM), (Description: The system has detected that the control links connecting the Primary and Backup racks of the Clustered system are not functional. Since XR cannot operate without the Primary DSC node, and a new one cannot be declared, this rack must be reloaded.), (Recommended Action: If this condition persists, check the physical connections between the RSP nodes connecting the racks. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-LSP_UPDOWN ### Response: (Severity: 5), (Category: ROUTING), (Description: The specified interface has changed operational state.), (Recommended Action: None. This is a solicited message (by 'logging event lsp-status state' \ interface configuration) and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_OC48-3-GET_NODEID_ERR ### Response: (Severity: 3), (Category: L2), (Description: SPA driver failed to obtain either its node ID or extract rack/slot/instance information (having obtained the node ID).), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-6-NODE_STATE_CHANGE ### Response: (Severity: 6), (Category: PLATFORM), (Description: Inventory Manager output this informational message whenever there is a card state change. This message will indicate the current card state.), (Recommended Action: This is a INFO message that a particular card state has changed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_HEAP-7-BAD_HEAPIDX ### Response: (Severity: 7), (Category: HA), (Description: Internally heap pointers are kept as offset indices. A given heap index was found to be outside the heap.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STREE-4-MSGSEND_FAIL ### Response: (Severity: 4), (Category: L2), (Description: stp_process is most likely in a bad state or basic system services have failed. stp_process error messages are generally indicative of health of control-ethernet which is critical for system operation. Misbehavior of stp_process can cause instability in the system.), (Recommended Action: Sysmgr process will restart the stp_process if it encounters this error. Check if the 'stp_process' is up and running if this error is encountered. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-INIT_MEDIA_DEV_ERROR ### Response: (Severity: 4), (Category: MEDIA), (Description: An unexpected media device error condition encountered during booting up from media), (Recommended Action: Collect system log information. Check that the media device and path are correct and that they exist and are accessible. Execute show media command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-UNSUPPORTEDARG ### Response: (Severity: 3), (Category: MGBL), (Description: 'left/right argument is of unsupported type'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEA_DLL-3-STATS_ALLOC_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Feature EA DLL failed to allocate statistics entry for ACL. Number of ACL entries requiring statistics entries has exceeded statistics entries reserved for security ACLs on this line card. As a result, per ACE hardware accouting for the failed ACL entries is not available. There is no impact on ability to apply security ACLs in hardware.), (Recommended Action: If per ACE hardware accouting is needed for ACL in error message, reduce security ACL configuration on this line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-CFG_APPLY_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The CFM Global Manager or the CFM Daemon on the specified node was unable to enact a set of valid configuration changes. Future configuration changes may be adversely affected and the protocol is likely not to operate as intended. The problem could be caused by a system resource issue.), (Recommended Action: Attempt to resolve any memory issues before attempting to solve this problem. After system resource issues have been resolved, issue 'process restart cgm' or 'process restart cfmd' on the affected node. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLMGR_UI-4-INVAL_DATA ### Response: (Severity: 4), (Category: APP_INFRA), (Description: The policymgr ui library received invalid data from the user interface. Ideally this should never happen and would be caused only by a bug in the code.), (Recommended Action: Try exiting and re-entering the config mode. If this doesn't help try restarting parser_server.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-1-ABORTING ### Response: (Severity: 1), (Category: HA), (Description: The system is experiencing CPU Hog, If this condition persists for 30 seconds, the node will be reloaded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JBI-7-DEBUG ### Response: (Severity: 7), (Category: PLATFORM), (Description: This is a debuging message from the altera JTAG player), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IPV6_EA-3-ERR_MEM ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Typically, this is an error where the memory allocation / access fails. Here is a list of possible reasons for this message (not all-inclusive). 1) Memory exhaustion due to overall system load 2) Shared memory access failure 3) Memory leaks leading to resource exhaustion), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show memory summary show cef ipv6 location <> show cef ipv6 trace location <> show cef platform trace all all location <> show memory location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEMLOG-3-TOOBIG ### Response: (Severity: 3), (Category: OS), (Description: A process attempted to malloc more than the maximum size of 16MB), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-NODEID_FAILURE ### Response: (Severity: 7), (Category: OS), (Description: An error happened for a nodeid operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-3-LOW_VOLTAGE_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected an SFP voltage less than or equal to the low voltage warning threshold. The SFP is the pluggable optics on the line cards. The voltage threshold values are read from the SFP.), (Recommended Action: Verify that the device is properly inserted. Check the 'show environment voltages'. If the system voltage is normal then replace the optics with working one (if any). If the system voltage is not normal, then make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA_MGR-3-BACKUP_MPAFPGA_LOADED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Backup MPAFPGA images has been loaded on the indicated card. This can happen when card manager detects that the Primary image is corrupted, and the HW fallbacks to load the backup image to recover from the failure.), (Recommended Action: Although the system will continue to run, the backup image set might be of older version and it might have known issues that have been fixed on latest version. So it is critical to address the problem as soon as possible. The output of 'show hw-module location fpd' will identify the image with the problem with NEED UPGD state and it will have missing Programmed version. To correct the problem, use the 'upgrade hw-module location fpd ' command to re-program the FPD image and power-cycle the affected MPA for MPAFPGA to load with the upgraded image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBUS-7-API_INVALID_SLOT ### Response: (Severity: 7), (Category: PLATFORM), (Description: mbus debug information indicating the invalid slot number), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPDRIVER-3-SBM_DMEM_MULTIPLE_BIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that during initialization the SBM SPICO DMEM for the indicated ring and NP had uncorrectable bit errors in instruction memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of using 'install disk-mirroring' in Cisco IOS XR? ### Response: The 'install disk-mirroring' command in Cisco IOS XR is used to configure disk mirroring for redundancy, ensuring data is copied across multiple disks for fault tolerance. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPT-3-FILTER_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: CPT filter error message. %s- Filter Name. %s- Target Name. %s- RSC Name.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-6-BADCHKSUM ### Response: (Severity: 6), (Category: ROUTING), (Description: OSPFv3 has detected a checksum error in an LSA due to memory corruption.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospfv3 - show ospfv3 database - show ospfv3 database database-summary - show ospfv3 trace all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER_MARK-7-NOT_FOUND ### Response: (Severity: 7), (Category: OS), (Description: The request for a page to be unmarked came, but no such marking was found in the reference array.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_EDM-3-SYSDB_BIND_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: The process failed to connect to SysDB while starting.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-NO_PLIM ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message informs the user that the linecard will not be powered on because there is no PLIM inserted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-4-SEND_PDU_TO_ISIS_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: CLNS was not able to send non-Hello class PDU to ISIS. This could be because of communication problems between CLNS and ISIS.), (Recommended Action: If this message is seen during transient conditions, for example when ISIS is restarting either because of install operation OR because ISIS crashed then it is not harmful. If the error message says out of memory, it is because of the queue between CLNS and ISIS being FULL which could either be because traffic rate is very high or ISIS might not be reading the packets. If it is seen under steady state conditions or re-occur then contact cisco-support. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SD-6-RESTART_SELF ### Response: (Severity: 6), (Category: SERVICES), (Description: The Service Director encountered an error when trying to send a control message, which could leave the system in an inconsistent state. The error results from an unexpected failure in the transport infrastructure. The process is now restarting and will then be able to resynchronize its state, restoring system consitency. This message is for informational purposes only, and no further action is required as a result. On completion of the resyncronization, the system will have self-healed, unless any further errors are encountered.), (Recommended Action: No action is required unless further errors are observed. If further errors are encountered, wait until possible root problems (such as node reload, or low memory conditions) have been resolved, and restart the Service Director. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_CHAN_SYNC_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-1 chan sync error on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-1-ERR_WRONG_CHASSIS ### Response: (Severity: 1), (Category: FABRIC), (Description: MINIQ Version 2 chassis type do not support sea/superstar based fabric cards. MINIQ Version 1 chassis type do not support superstar based fabric cards. This is because of unsupported backplane in these chassis.), (Recommended Action: Replace the chassis.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_RP-3-CERR_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the cerrno module in the platform L2FIB component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-3-OBFL_CACHE_OVERFLOW ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message related to the Canbus Controller processing the received UART message.), (Recommended Action: restart canb-server.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-MEM_WRITE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: CPP driver failed to write to memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-COMMS_RETRY_FAILED ### Response: (Severity: 4), (Category: L2), (Description: A Frequency Synchronization process has failed to send a message and attempts to retry the send have also failed.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON_EA_OOR-4-NP_FLOWS_OOR_RED ### Response: (Severity: 4), (Category: PLATFORM), (Description: Performance traffic monitoring has encountered an out-of-resource condition. Performance traffic monitoring process on the linecard has detected that the number of flows being monitored on a NP has reached maximum capacity. New flows will no longer be learnt), (Recommended Action: Reduce the number of flows being monitored on the NP. This can be done by 1) Modifying ACL: (a) Remove the performance traffic service policy from the interface (b) Modify the ACL used in the service policy to be more specific to match a smaller set of flows to be monitored (c) Reapply the service policy to the interface 2) Moving monitored flows to a different interface on a different NP) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-3-CONNECT_FAILED ### Response: (Severity: 3), (Category: OS), (Description: The Linux Packet classifier failed to establish a connection to the GSP messaging group, after multiple retry attempts. It will continue to retry, but the Linux packet path will be unable to handle traffic until a connection is established. The XR packet path should be unaffected.), (Recommended Action: Periodic attempts to connect will continue to occur. If this message continues to be seen, it may indicate a problem with GSP. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPM-6-INFO_PULSE_CODE ### Response: (Severity: 6), (Category: SECURITY), (Description: An internal error occured because an unsupported pulse code is received.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX-2-CONFIG_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: There was an fail during PEX (PCIE Switch) driver configuration.The error message has detailed information. Config fail will usually result in process restart in an attempt to configure the PCIE server.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-4-FAILOVER_REQUESTED ### Response: (Severity: 4), (Category: HA), (Description: Redcon on the active card has been told to failover by request), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEM_PLATFORMS-2-ERR_IFH_STS ### Response: (Severity: 2), (Category: L2), (Description: Error in cem operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-3-OPERATION_FAIL ### Response: (Severity: 3), (Category: LICENSE), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_LOSS_OF_SIG ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCM-6-FUNC_ENTRY ### Response: (Severity: 6), (Category: L2), (Description: An info regarding a particular method getting hit in atm_vcm. It eases the debugability part and has no functional/ operational impact.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REBOOT_LIB-3-SHUTDOWN_DELAY_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: Failed to get the clocktime, reload is proceeding without any delay.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-BIQ_EMPTY ### Response: (Severity: 3), (Category: PLATFORM), (Description: NP detects BIQ_EMPTY and reported through interrupts), (Recommended Action: No specific actions needed. The software should be able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-OPERATION_WARN ### Response: (Severity: 4), (Category: PLATFORM), (Description: The particular operation mentioned in the message occured due to some reason. This may be a serious failure, however process may continue functioning as expected (or successfully retry) despite the failure.), (Recommended Action: Give CLI:) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTAGENT-4-SELF_TEST_HOST_ADMIN_MISMATCH_MSG ### Response: (Severity: 4), (Category: INFRA), (Description: The install software component has detected that the local installed software on host and sysadmin are not same relative to the software installed on the rest of the system. This event may be caused by the reloading the sysadmin after system upgrade or ISSU without doing install commit. Install component will try to auto correct this issue.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-6-INTRFC_STATE_QUERY_FAILED ### Response: (Severity: 6), (Category: SECURITY), (Description: An internal software error occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-FILE_IO ### Response: (Severity: 3), (Category: MGBL), (Description: Unable to read/write the file), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTR7 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-7-REPOPULATE_SHADOW_REQUIRED ### Response: (Severity: 7), (Category: MGBL), (Description: Configuration accepted by the actual verifier processes was rejected when writing it into the shadow namespace. An attempt will automatically be made to repopulate the shadow namespace to bring it back in step with the actual configuration.), (Recommended Action: The Central Configuration Validator (CCV) will attempt to repopulate the shadow namespace and will report a further message indicating any further failures (with suggested recovery steps) or reporting that the repopulation was successful.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCCLASS-3-ATTACH ### Response: (Severity: 3), (Category: MGBL), (Description: An ATM VCCLASS consumer has attempted to attach an unknown vcclass to its interface.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-4-PROC_EXIT ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal message), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLDP-5-ENABLED ### Response: (Severity: 5), (Category: ROUTING), (Description: MLDP has been enabled by configuration.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_VCM_EA-3-BATCH_INTERFACE_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The FR VCM EA process has detected an error during messaging. Possible memory corruption or out of resource.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-1-PLANE_UPDOWN ### Response: (Severity: 1), (Category: FABRIC), (Description: If the plane is reported down other than when administratively brought down, it means that the sprayer cannot reach *any* destination on the plane. This is a symptom of too many other fabric errors (DESTINATION_UPDOWN) than an error itself. The plane can no longer be used to send any traffic. If the plane is reported mcast_down, it means that certain fabric destinations are not reachable on this plane.It is still good for unicast traffic, but for destinations which are reachable on this plane.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD_NETIO_TOPAZ_DLL-3-INCORRECT_IDB ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: FWD was supplied with a plim interface that does not have an idb yet.), (Recommended Action: No Action required Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-4-RX_BAD_ADDR_TYPE ### Response: (Severity: 4), (Category: ROUTING), (Description: Invalid address received from peer for given address family.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_DIR-3-PREVIOUS_UPGRADE_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The ISSU infrastructure has identified that a previous sysadmin ISSU operation has failed. The system must be reloaded in order to recover to the committed version.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_0_ERR1_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 0 ran into error-1 on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-TS_LS_PWM_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected a pwm bit error), (Recommended Action: Please try to correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_EDM_NOT ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_5_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COPYMIB-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: SNMP), (Description: No memory to perform edm or bag operations.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_CFG-3-BGP_MULTIPATH_PIC_RELOAD_REQ ### Response: (Severity: 3), (Category: FABRIC), (Description: If the hw-module command is used to configure BGP MULTIPATH PIC CORE and router is not reloaded, there will not be any effect.), (Recommended Action: In order to enable BGP MULTIPATH PIC CORE, the router must be manually reloaded.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-5-GR_NBR_ID_CHANGE ### Response: (Severity: 5), (Category: ROUTING), (Description: A previously known GR peer has reconnected with a new ldp-id. This message appears only if the mpls ldp log graceful-restart command is configured.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-ISSU_EVENT_BLOCK ### Response: (Severity: 3), (Category: INSTALL), (Description: Issu thread failed while waiting for incoming events. Issu operation process will exit with failure. Node may be reloaded.), (Recommended Action: Retry the issu operation.If error persists. contact tac with 'show tech-support issu'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ST16550-3-SCHEDPARAM_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The ST16550 UART driver was unable to set the parameters of the interrupt handler.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRD-3-LOOP_FAILED ### Response: (Severity: 3), (Category: SERVICES), (Description: An unexpected error has been encountered in the main Service Role Daemon event loop. The Service Role Daemon will be automatically restarted, and should recover by itself.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-UPDATE_DISCARDED ### Response: (Severity: 7), (Category: HA), (Description: During failover/switchover old active has not gone standby yet and sends update to the new active. These updates need to be discarded and success needs to be returned. Log is used in case debugging is required to check what type of update has been discarded.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_FPD-6-UPDATE_START ### Response: (Severity: 6), (Category: L2), (Description: The FPD update update operation has started for the specified image.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLMGR_UI-3-NOMEM ### Response: (Severity: 3), (Category: APP_INFRA), (Description: The node which logged this message is running low on memory and the requested operation could not be completed.), (Recommended Action: Either reduce the configuration applied on this node or increase its memory. If the error is persistent, contact TAC with required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_NB_SERDES_6_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data north bound serdes link 6 failure on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-3-SFP_I2C_TM_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Port controller driver detected I2C timeout error on SFP port.), (Recommended Action: Ensure that the SFP plugged in is supported. If not, please replace the SFP. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-4-LTRACE_INIT_ERROR ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates that LDA failed to initialize the internal debug tracing. While this doesn't affect router functionality, it does limit the ability to debug failures in the LDA and LC driver subsystem.), (Recommended Action: No urgent action is required for this message. However the issue should be addressed by performing a process restart at a convenient time such as next available service window.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TOMAHAWK-4-WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: Tomahawk RP Kensho-JF CPU Subsystem DLL warning message. No system functional impact.), (Recommended Action: Nothing. Reporting normal progress of Tomahawk RP Kensho-JF CPU Subsystem DLL.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-4-CHKPT_ITERATE ### Response: (Severity: 4), (Category: ROUTING), (Description: The MRIB encountered error while trying to iterate through the checkpoint records. This error may occur during - starting an iterator - finding next record in the iterator - ending an iterator), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GT_I2C-3-LOWER_FANTRAY ### Response: (Severity: 3), (Category: PLATFORM), (Description: As shown in the message.), (Recommended Action: Physical OIR of lower fan tray required to recover from this hang.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-DDR_BUS_BIT_STUCK_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: DDR bus databit stuck on bridge instance-2.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMACTRLR-3-PORT_NOT_CREATED ### Response: (Severity: 3), (Category: L2), (Description: IMA controller port was not created. This can occur under the following instances, * when the initialization of IMA controller fails. * when the IMA controller and IM(interface manager) interaction init fails. * when the create IM data for the IMA port fails.), (Recommended Action: Collect the following outputs, Copy the error message exactly as it appears on the console or in the system log. Issue the show ima trace location <>/<>/<> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show ima trace location <>/<>/<> output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show controller MgmtIMA <>/<>/<> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controller MgmtIMA <>/<>/<> output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show run controller MgmtIMA <>/<>/<> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show run controller MgmtIMA <>/<>/<> output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support pfi command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support pfi output, call your Cisco technical support representative and provide the representative with the gathered information. Remove and Re-apply the IMA controller configs. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR_HELPER-4-INIT_ERROR ### Response: (Severity: 4), (Category: MEDIA), (Description: An unexpected init error condition encountered.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-4-PCIE_LINK_ERR ### Response: (Severity: 4), (Category: INFRA), (Description: The PCIe Link betwen the PCIe bridge on the SC card and the PCIe Bridge on the SW card is not up even after driver attempted reset and recovery actions. The driver triggers a critical fault to be reported to the Fault Manager asking it to reload the SC card on which its running and if it is local, then SW card also.), (Recommended Action: No action is required from the operator.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_NETIO-7-BAD_ARP_DROP ### Response: (Severity: 7), (Category: ROUTING), (Description: MPLS slowpath got a packet for which ARP needs to be done, but, it doesn't have the nexthop needed. The pkt is dropped.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure BGP AS path filtering in IOS XR? ### Response: BGP AS path filtering in IOS XR is configured using route-policies to match and manipulate routes based on their AS path attributes. route-policy AS-PATH-FILTER if as-path in AS-PATH-SET then drop endif end-policy router bgp 65000 neighbor 203.0.113.6 route-policy AS-PATH-FILTER in commit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HPI-3-MMAP_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: mmap pdma descriptor failed.), (Recommended Action: Check the error code and contact infra team.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN-3-MMAP_FAILED ### Response: (Severity: 3), (Category: OS), (Description: SHMWIN encountered an error when mmap memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - show shmwin participant list - show memory location 0/x/CPUx - show shmwin trace all location 0/x/CPUx) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAW_LIB-3-EDM_ERR_CODE ### Response: (Severity: 3), (Category: MEDIA), (Description: Capture EDM errors for reboot history with error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GE_DMAC-3-MLAN_LINK_STATE_CHANGE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The internal link interface for the specified port is down.), (Recommended Action: Gather the data listed in 'required_info'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-6-PORT_STATE_CHANGE_LINK_DOWN ### Response: (Severity: 6), (Category: INFRA), (Description: Informational message indicating that the physical link state of the specified port has changed to down.), (Recommended Action: This is an informational message and does not necessarily indicate a problem. The port's physical connection should be checked if an unexpected status change occurs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_12_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_12 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-ACCESS_FAILURE_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef trace location <> show cef platform trace all location <> show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_2_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEPKI-6-ERR_2 ### Response: (Severity: 6), (Category: SECURITY), (Description: CEPKI general error message with two prameters.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-1-FATAL_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: This is an severe error message in the OFA module to indicate that an error was seen during init operation.), (Recommended Action: Please collect the console log, OFA traces (show ofa trace loc <>), Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ND_REQUEST_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: A request to resolve IPv6 next-hop addresses failed for the specified error reason.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-FIFO_0_OFLOW_FIA2BR_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: FIFO-0 FIA to bridge instance-2 overflow.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-INTERNAL_LIMIT_OIDS ### Response: (Severity: 4), (Category: SNMP), (Description: SNMP agent recieves more than 75 requests at a time from NMS leading to buffer pool exhaustion blocking all the upcoming OID's leading to timeout.), (Recommended Action: Kindly reduce the number of oids per request to avoid request timeouts) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ETHER-2-XGXS_DTE_SYNC_ERROR_THRESHOLD ### Response: (Severity: 2), (Category: L2), (Description: The PLA MAC xgxs DTE layer went down due to loss of sync or lane alignment. The daily event threshold was crossed so the serdes was reset. The traffic may start getting dropped after this error message.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_APS-4-WARNING ### Response: (Severity: 4), (Category: L2), (Description: A non-fatal error occured while executing the function in question. The message contains info about the cause of the failure and possibly anticipated actions/effects.), (Recommended Action: Verify continued correct operation of SONET APS.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCRIPT_MGMT-6-INFO ### Response: (Severity: 6), (Category: OS), (Description: Informational messages only.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-2-RACK_DOWN ### Response: (Severity: 2), (Category: FABRIC), (Description: This message indicates LCC or fabric rack has been removed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-NSR_STATE_CHANGE ### Response: (Severity: 5), (Category: ROUTING), (Description: BGP changed its global NSR state.), (Recommended Action: This informational message appears when BGP changes its global NSR state.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_12_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_12 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-3-SELECT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Select failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check the card is inserted properly if it is externally accessible. Capture 'show media' and 'show filesystem ' together with console log.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE tunnel selection metric feature? ### Response: The MPLS TE tunnel selection metric feature allows the configuration of the metric type to be used for tunnel path calculation and selection. The default is to use the TE metric which is carried in TE LSAs. Alternatively, the IGP metric can be used which is the normal OSPF or IS-IS metric. This provides flexibility in optimizing tunnel paths. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_OPTICS_SW_HW_INCOMPATIBLE ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-PTHREAD_CREATE ### Response: (Severity: 3), (Category: MGBL), (Description: Unable to create exec's event handling thread), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_0_PKT_MINLEN_ERR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet minimum length error on NPU-0 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRLLIB-4-PORT_NOT_PRESENT ### Response: (Severity: 4), (Category: PLATFORM), (Description: Port will not operate reliably), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_11 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_BAG_DECODE ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-ERR_MEM ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in FIB MPLS. Typically, this is an error where the memory allocation / access fails. Here is a list of possible reasons for this message (not all-inclusive). 1) Memory exhaustion due to overall system load 2) Shared memory access failure 3) Memory leaks leading to resource exhaustion), (Recommended Action: Please collect the console log and the CLI output. show cef show memory summary show cef location <> show memory location <> show cef trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE2_LANE_CRC_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE2_LANE_CRC_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-5-SR_POLICY_CPATH_PROTECTION_READINESS_CHANGE ### Response: (Severity: 5), (Category: OS), (Description: Protected CPATH readiness has changed for a particular SR Policy), (Recommended Action: If the protection readiness is down, then it means that dataplane may dropping traffic in the event of active path breakage. If the protection readiness is up, then it means that a backup CPATH for the given policy is tested and ready to handle path breakages.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-3-ERR_DSC ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID Server encountered DSC error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-6-PROBLEM_EXITING ### Response: (Severity: 6), (Category: SERVICES), (Description: The process implementing service diversions (eg for virtual firewalls) has just exited, since the last service attachments have just been deconfigured. As part of this orderly shutdown, the process tried to inform System Manager that this was happening, but hit a problem in signalling this fact. The system should have recovered from this problem fully; however, very rarely it is possible that some other service attachment configuration in the same commit could be rejected.), (Recommended Action: If any service attachments in the same configuration commit were rejected, simply re-commit them.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-NOT_SUPPORTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Quality ITU-T Option 1 does not support SONET framing, only SDH framing.), (Recommended Action: If SONET framing is required, need to change quality ITU-T to Option 2) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT_SWITCH-3-LINK_FAIL_24 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Punt link failed), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to set RSVP message pacing in Cisco IOS XR? ### Response: To set RSVP message pacing, use the 'rsvp message-pacing' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#rsvp message-pacing <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-1-RX_EOP_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered interlaken Rx missing EOP error.), (Recommended Action: This fault would result in traffic loss. Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-VETO ### Response: (Severity: 3), (Category: INFRA), (Description: When notified about this install operation, one or more IOS-XR processes vetoed the operation. The operation cannot proceed further.), (Recommended Action: Examine the reasons given for the veto or vetoes, take any recommended actions and try the operation again. The full set of reasons is recorded in the install operation history.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-SRV6_CAP_COMPILE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Unexpected error while parsing SRv6 capability subTLV in an incoming LSP The problem is unexpected and most likely to be an internal programming error. Most likely the ISIS LSP database will no longer reflect the true status of the network), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the IS-IS process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-SHUTDOWN ### Response: (Severity: 7), (Category: SYSDB), (Description: A SysDB server process has performed a graceful shutdown and will be restarted.), (Recommended Action: Check to make sure the process has restarted. If not, restart manually. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-6-SCHEDULE_IS_REMOVED ### Response: (Severity: 6), (Category: DIAG), (Description: The scheduled online diagnostic tests are no longer configured. This message usually appears after a scheduled test is removed by the user or a card is removed from the chassis.), (Recommended Action: If you want the scheduling tests to be removed, do nothing. If you want the scheduled tests to still be run, reconfigure the scheduled tests.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BPE-7-ERR_EXIT ### Response: (Severity: 7), (Category: PLATFORM), (Description: An error occurred in BPE Driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: If the process keeps restarting ,reload using CLI Command in admin mode - reload location <> If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-4-JID_GET_ERROR ### Response: (Severity: 4), (Category: OS), (Description: process's JobID can not be obtained), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_PCL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS encountered an unexpected error whilst performing the specified using the Route Policy client library. As a result information may be omitted from the local system's LSPs. This may be due to a low-memory condition.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the IS-IS process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_MCAST_SIZE_ERR ### Response: (Severity: 4), (Category: ROUTING), (Description: The multicast address requested for the specified interface is larger than the maximum permissible size. This requires restarting the IS-IS process.), (Recommended Action: Restart the IS-IS process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-TUPLE_PACK ### Response: (Severity: 3), (Category: MGBL), (Description: The call to tuple_pack() failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC13 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-1-FANTRAY_FAILED ### Response: (Severity: 1), (Category: PLATFORM), (Description: This mesage indicates more than one fan failed on the mentioned fan tray), (Recommended Action: RMA the failed fan tray) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_EA_TEST-3-ERROR ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INVMGR-6-INFO_LOG ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an information log.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LSPV_DPM-4-ADJ_FAULT_NOTIFICATION ### Response: (Severity: 4), (Category: ROUTING), (Description: During an iteration of DPM a fault was detected. For more detailed information regarding faults, view 'show mpls oam dpm adjacency fault'), (Recommended Action: Forwarding over the given adjacency may not be deterministic nor stable. We recommend running 'show mpls oam dpm adjacency fault' to determine all faults discovered thus far. If any are unexpected, review the control plane expectations and investigate the extent of the forwarding fault.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-AAA_STRING_TASKID_CHECK ### Response: (Severity: 3), (Category: MGBL), (Description: 'Special taskid string check against user taskmap failed'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_15_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_15 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-BUILD_TABLE_FAIL ### Response: (Severity: 3), (Category: INSTALL), (Description: Unexpected null string.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-2-MUTEX_INIT_FAILURE ### Response: (Severity: 2), (Category: FABRIC), (Description: Fia driver mutex initialization error), (Recommended Action: Try reloading the fia driver If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-6-DISKSPACE_CHECK_PASS ### Response: (Severity: 6), (Category: INSTALL), (Description: The device now has enough diskspace for install code to proceed.), (Recommended Action: No action needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are BGP peer groups and what are their benefits? ### Response: A BGP peer group is a group of neighbors with the same update policies. Update messages generated for one member of a peer group are replicated for all other members. Benefits include conservation of memory and CPU resources, configuration simplification, and faster convergence. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_FIB-3-ATTR_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message in the SSE FIB to indicate that engine layer identified an error with attribute passed by upper layers), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CBC-3-CANBUS_FANTRAY_INRUSH_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: CBC has detected that the inrush fantray has failed. This will result in the LCs getting overheated. Please turn off power to the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-7-BPM_CHKPT ### Response: (Severity: 7), (Category: ROUTING), (Description: The BPM failed to record the allocation in the checkpoint table. This could cause operational problems if the BPM is later restarted.), (Recommended Action: No further action is necessary unless the BPM restarts. In that case, if problems are seen it may be necessary to deconfigure BGP completely and then reconfigure it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-BF_SBE_ERR_FIA10 ### Response: (Severity: 3), (Category: PLATFORM), (Description: FIA10 burst FIFO single bit error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COND_DEB_RP-3-INSUFMEM ### Response: (Severity: 3), (Category: SECURITY), (Description: The requested operation could not be accomplished because of a low memory condition.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-3-THREAD ### Response: (Severity: 3), (Category: L2), (Description: An error occurred in a thread during an operation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_HAL-3-PARAM_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An unexpected parameter inconsistency has been detected in the hardware abstraction layer of the Forwarding information Base.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE interarea tunnels feature? ### Response: The MPLS TE interarea tunnels feature allows MPLS TE tunnels to be established across IGP area boundaries. This enables TE to operate in multi-area environments. Interarea TE tunnels comprise hops in different IGP areas and are signaled as a contiguous end-to-end LSP. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-4-LRD_FAIL ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when using a logical router daemon api), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD_inv-3-MSG_INVENTORY_FWD ### Response: (Severity: 3), (Category: HA), (Description: LRd was unable to read or write information needed to forward inventory in Admin space to the LR Plane.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_RESYNC_SCHED_IIR ### Response: (Severity: 4), (Category: L2), (Description: An attempt to schedule a resync with IIR has failed for this bundle. The safest course of action is to restart the process and this has been done.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-BAD_LWM_VERSION ### Response: (Severity: 7), (Category: OS), (Description: An error was received while processing a request from a local process. There could be a version mis-match or corruption in the client process. The error message should provide some clue to the problem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does System Manager start and manage processes on IOS XR? ### Response: System Manager starts processes based on the configuration in their process startup files. These files specify process name, path, instances, startup conditions, criticality, and placement. Sysmgr monitors each process and restarts it according to the restart policy if it fails. It can also start processes dynamically when certain config is committed. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-DEC_A_FRAME_ERR_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Decoder A framing error on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APPMGR-2-RSYNC_FAILED ### Response: (Severity: 2), (Category: INFRA), (Description: The IOS-XR appmgr has failed to sync files to the standby node. In order to bring the node back into sync, the following steps can be taken: - Restart the process appmgr on the active RP. This will force a resync. - If restarting the appmgr process results in the same message being displayed, the standby node should be reloaded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: C_SHIM_PARTNER-7-IFH_ERR ### Response: (Severity: 7), (Category: L2), (Description: 'Receive a message with wrong interface handle. This may be ignored.'), (Recommended Action: Ignore) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-4-NO_VLDN_METADATA ### Response: (Severity: 4), (Category: MGBL), (Description: This failure indicates that either there were no validation metadata files found, or none could be loaded successfully. Config validation will not be possible for any configuration until this condition is resolved.), (Recommended Action: The failure to find or load the metadata should be investigated, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-6-LATCHING_SESSION_STOPPED ### Response: (Severity: 6), (Category: L2), (Description: A best-effort attempt to stop a session has been made. If an error occurred in cleaning up the session on a particular LC the SESSION_NOT_STOPPED message will be generated on that LC.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-MGD_TIMER ### Response: (Severity: 4), (Category: L2), (Description: ELMI encountered an unexpected error using the Managed Timer library. This is most likely to be due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the ELMI process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_ALLOC-3-ERR_SYSMGR ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID Allocator encountered the annunciated sysmgr error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-4-CERR_REGISTER ### Response: (Severity: 4), (Category: SECURITY), (Description: locald failed to register error codes.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to specify RSVP hello intervals? ### Response: To specify RSVP hello intervals, use the 'rsvp hello-interval' command in interface configuration mode. RP/0/RSP0/CPU0:router(config-if)#rsvp hello-interval 10 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-3-SPA_SELF_DESTRUCT ### Response: (Severity: 3), (Category: L2), (Description: This is an error message indicating a Hardware access error for a SPA. If this is a recurrent message, it usually is due to faulty hardware, loose connection at the SPA connector on the jacket card. Try reseating the SPA and see if the issue is resolved. If not, please check with TAC.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-3-FAA_FA_CB ### Response: (Severity: 3), (Category: SECURITY), (Description: An error occurred in FAA or associated services whilst it was attempting to process the creation, update, or removal of default failure action configuration for a Virtual Firewall. More information on the course of the failure is contained in the message.), (Recommended Action: If the error message indicated that a lack of resource was to blame for this error, make more resource available on the indicated node, then restart the rspp_ma process on this node using the 'process restart' command. Otherwise, roll back the configuration change, wait 10 seconds, then re-apply the configuration. If the error is still seen, restart the RSPP MA process on the node indicated using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-4-INSTALL_READY_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: The attempt to notify install manager of install complete failed. If this is the initial startup, there should be no side affects. If this is the result of a software upgrade/downgrade, it is likely the process will be restarted by sysmgr after a timeout period.), (Recommended Action: Check the install logs if all the packages are downloaded and install operations completed properly Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_MGR-3-ECM_ERROR_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The SVII Adjacency Manager encountered an error while calling AIB. Normally, it would recover from this error. However, a secondary failure has occurred while invoking the recovery mechanism. After this error, packets may not be forwarded correctly for some service virtual interfaces.), (Recommended Action: The system can be recovered by restarting the 'svi_adj_mgr' process on the affected node. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-5-RELOAD_EVENT_CANCELLED ### Response: (Severity: 5), (Category: PLATFORM), (Description: This message indicates that a previous delayed reload event is being cancelled due to multiples ungraceful reloads on the indicated node.), (Recommended Action: *none*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-7-ERR_CREATEMQ ### Response: (Severity: 7), (Category: ROUTING), (Description: The process failed to create a message queue to communicate with MPLS.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-3-FMEA_FAULT_NORELOAD ### Response: (Severity: 3), (Category: PLATFORM), (Description: FMEA Event. Details as per format string.), (Recommended Action: The board will NOT be reloaded. At this stage please collect the output of (admin)'show tech support control ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-6-CONN_UNREG ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR-3-THRESH_RESET_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error in clearing asic-error threshold for a particular error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-5-MAP_SERVER_REGISTER_AUTHENTICATION_FAILURE ### Response: (Severity: 5), (Category: IP), (Description: 'Map-server failed to authenticate map-register for ' 'EID prefix. This is potentially caused by different ' 'shared keys configured on ETR and map-server.'), (Recommended Action: 'Ensure ETR and map-server have the same ' 'configured shared key.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-4-NO_OPTICS ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message provides information about the fault occurred on the interface.), (Recommended Action: The message is just for information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-6-ENFORCE_GRACE ### Response: (Severity: 6), (Category: LICENSE), (Description: The licensed feature is enabled in grace period.), (Recommended Action: The customer may consider to purchase licenses.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-0-EMERG_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: PLATFORM FIB, Tomahawk specific init error), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>), 'show install active', 'show logging console', 'show platform' and 'show version'. Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LICENSE-6-ENFORCE_OVERAGE ### Response: (Severity: 6), (Category: LICENSE), (Description: The customer has purchased one or more of these licenses from Cisco and all of those licenses are already in use.), (Recommended Action: The customer should consider purchasing more licenses.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-4-CONFIG_GEN_ERR ### Response: (Severity: 4), (Category: MGBL), (Description: Generation of configuration in ASCII format has failed. During periodic backup operation this may lead to internal backup files not getting updated with recent config changes), (Recommended Action: For a system initiated ascii generation please run 'show running cache refresh' in SDR mode. Look for similar IOS messages for additional recommended actions. Collect the show logging output, console logs, tracebacks, show nvgen trace output, show runnning output, show config history and show tech-support sysdb.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_7_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_7 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-SHM ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred that prevented the FIB from working properly with shared memory.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-3-INSUFFICIENT_PERMISSIONS ### Response: (Severity: 3), (Category: IP), (Description: A non-root user has attempted to perform an XR socket operation which can only be performed by root users.), (Recommended Action: The information in required_info to be collected and engineering team to be notified. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-ERR_BAG_REG ### Response: (Severity: 3), (Category: PLATFORM), (Description: EDM Bags are used to share information between components using sysdb. This Error indicates that bag registration failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-APS_INFO ### Response: (Severity: 3), (Category: OS), (Description: An unexpected error occurred.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-PROC_SHUTDOWN_NAME ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure RSVP refresh reduction? ### Response: To configure RSVP refresh reduction, use the 'rsvp refresh-reduction' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#rsvp refresh-reduction <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-ERR_MAC_RELEASE ### Response: (Severity: 5), (Category: L2), (Description: After a resync with the MAC address allocation server, the Bundle Manager process found that it had more MAC addresses than required by the bundle configuration settings and tried to release some to the server. However, this operation failed, so these extra MACs were kept in the Bundle Manager allocation. This is not an issue unless there is a shortage of MAC addresses for another feature (e.g. Interflex).), (Recommended Action: If there is no other feature that is short of MAC addresses, no action is required. Otherwise, try adding and deleting an additional Bundle-Ether interface (with no members). Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-INVALID_MHOST_DEFAULT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_CFG-2-SE_PROFILE_CONFIG_REJECTED ### Response: (Severity: 2), (Category: FABRIC), (Description: SE MDB profile cannot be configured on non-TCAM devices), (Recommended Action: Un-configure SE MDB profile hw-mod CLI in the device) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-2-UNEXPECTED_NODE_DURING_OP ### Response: (Severity: 2), (Category: INFRA), (Description: The IOS-XR install infrastructure detected that a remote node has started running IOS-XR in the system. However, since the node is not involved in the install operation, it should be kept out of service until the next install commit is been performed. This situation may occur if a node is reloaded during an install operation, or if a node error occurs during the reload stage of an apply by reload operation. Note that: - This reload is automatic, and does not involve any user intervention. - The node in question will be out of service until the re-imaging process is complete. - The re-imaging process will not complete until 'install commit' is issued - After the re-image, the system should be restored.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_UIDB-3-MNGR_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: The process exiting because of failure in uidb manager.), (Recommended Action: *SH_CMD show controllers pse qfp infrastructure uidb input base location<>*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-MISS_EOP_1_FIADDR_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Missing EOP-1 from FIA DDR on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-5-PROGRESS_ERROR ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: The satellite has indicated an error has occured when attempting the requested install operation.), (Recommended Action: If the satellite is retrying, no action is needed. Otherwise, the install operation should be aborted and retried if necessary.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-MUTEX_OP_FAILED ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: The packet subsystem failed to perform the specified operation on the specified mutex. This usually indicates a programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-HARD_RESET_COMPLETE ### Response: (Severity: 4), (Category: PLATFORM), (Description: Hard reset recovery action is complete and the network processor is operational.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-4-BASE_CAPS_LU_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: The Interface Manager returned an unexpected error when CLNS attempted to lookup an interface's base capsulation type. This may be a resource problem but is probably an internal error.), (Recommended Action: Consider restarting the CLNS and/or Interface Manager processes. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-3-PARAM_ERR ### Response: (Severity: 3), (Category: L2), (Description: An illegal parameter has been passed to a function in the IPv4 Forwarding Information Base.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-FIFO_0_OFLOW_NPU2BR_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: FIFO-0 NPU to bridge instance-3 overflow.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-OLD_IDPROM_FORMAT ### Response: (Severity: 3), (Category: DRIVER), (Description: Outdated IDPROM format is being detect for the indicated card. The card will not operate correct without being upgraded to use the TLV format.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MARVEL-3-CHAN_CREATE ### Response: (Severity: 3), (Category: L2), (Description: Failed to create marvel-test (driver) channel using event_manager_create.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-5-DISJOINTNESS_STATUS_CHANGE ### Response: (Severity: 5), (Category: OS), (Description: Disjointness status has changed. This can happen for example if the PCE cannot meet the requested disjointness type and has to perform fallback, or when a disjoint group that was previously in fallback mode recovers and the requested disjointness is satisfied once again.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ROULETTE-3-ALARM_INDICATION ### Response: (Severity: 3), (Category: PLATFORM), (Description: Alarm indication received from Roulette. This may be a serious failure (example: power sequencer failure), however process may continue functioning as expected (or successfully retry) despite the failure.), (Recommended Action: Provide the following CLI: (admin)# show env Use the pid from canb-server output to look for matching pid in the pfm output. If the alarm indication does not clear within 30 minutes, contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTP1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_MGD_TIMER ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA encountered an unexpected error using the Managed Timer library. This is most likely to be due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the PPPoE MA process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-3-POLICY_WARNING ### Response: (Severity: 3), (Category: QOS), (Description: Bandwidth over subscription is supported only on single priority across subinterfaces. process ltrace will have more information.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_IN_MEM_UCORR_ECC_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast input memory uncorrectable ECC error on link 2), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-INIT_ERROR_MSG ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is a debug message in the NP Driver to indicate an operation or condition.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_INFRA-4-DEBUG_SCRIPT_FAILURE ### Response: (Severity: 4), (Category: INSTALL), (Description: Debug scripts are collected to preserve diagnostic information following an event triggering the abort of the ISSU operation. Failure to collect the diagnostic data may make triaging the abort event more difficult and the ISSU operation should not be cleaned up until the abort has been manually triaged.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-UPDATE_CHASSIS_PROM ### Response: (Severity: 4), (Category: DRIVER), (Description: Virtual Interface Mac pool start/end address has been configured in Chassis prom. This will provide the Mac addresses required in XR VM.), (Recommended Action: Use idprom_tool to upgrade the backplane IDPROM.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS DiffServ tunneling modes? ### Response: The MPLS DiffServ tunneling modes define how the MPLS experimental (EXP) field is treated when IP packets enter an MPLS tunnel. The pipe and short-pipe modes preserve the original IP precedence. The uniform mode allows the IP precedence to be overwritten by the MPLS EXP value. It is configured with the tunnel mpls traffic-eng exp command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-4-THRESHOLD_BREACHED ### Response: (Severity: 4), (Category: INFRA), (Description: The specified SLA threshold has been breached in the current bucket and the corresponding action has taken place.), (Recommended Action: The breaching of this threshold indicates that the performance of the network has dropped below the configured threshold level. The cause of this performance degredation should be investigated and fixed so that the threshold can be cleared.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGPTE_LIB-4-CLIENT_ERR_MEM_ALLOC ### Response: (Severity: 4), (Category: ROUTING), (Description: The process failed to allocate memory for the specified resource.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-7-REPLICATE_DPC_INVALID_COOKIE ### Response: (Severity: 7), (Category: IP), (Description: IPv4 MA got an unexpected cookie for the specified interface. This failure indicates that the IPv4 data path feature may not programmed correctly.IPv4 MA tries to recover from this error by a timer based retry.If the message is not seen continuosly for a particular interface and if functionality looks ok, the recovery might have been successful.), (Recommended Action: Collect the output of show tech-support, show ipv4 ma trace, debug imp dpc, debug ipv4 events, debug im api job <> from the location the error message comes from. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-REMOVE_OLDEST ### Response: (Severity: 6), (Category: OS), (Description: Memory limitation.), (Recommended Action: This is an informational message. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-5-IDP_INTENT_VER_OLD_DISCARD ### Response: (Severity: 5), (Category: SERVICES), (Description: 'The device received an old intent file ' 'by Intent Distribution Protocol and is discarding it'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_1_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-4-ERR_RETRY_TRANS_SPEC_INIT ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-2-ACT_RSP_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: LC CPU controller driver detected inconsistency between raw and decoded active RSP signals.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: tunnel_ea-3-DEBUG_INIT_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This is an internal initialization error.), (Recommended Action: If there is a problem, it might be cleared by restarting tunnel_ea. If the problem persists, copy the error message as it appears on the console and any noticeable side effects. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-5-MAP_SERVER_REGISTER_NO_CONFIG_EID_PREFIX ### Response: (Severity: 5), (Category: IP), (Description: 'No site is configured to accept registration for EID prefix.'), (Recommended Action: 'Configure EID prefix in map-server site to ' 'enable registration.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-0-ASIC_ERROR_SHUTDOWN_BOARD ### Response: (Severity: 0), (Category: PLATFORM), (Description: An ASIC error has occured and board need shutdown.), (Recommended Action: An error has happened and board is shutdown. Collect required information and contact TAC *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_CLIENT-3-SHMEM_CORRUPTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ethernet server detected shmem is corrupted for its client. This indciates there would be few packet loss and server will intialize the shmem to recover this condition. client will take care of retransmitting the packet.), (Recommended Action: 'None, Eth server will correct the condition by itself by Re-initializing the shared memory') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-TSPI_CAL_ECC_MBE ### Response: (Severity: 1), (Category: PLATFORM), (Description: TxSPI Calendar ECC multiple bits error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_MGR-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: FABRIC), (Description: FGID failed to allocate memory), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_RP-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, error information), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-IFH_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_CPP_PM-4-WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: The Platform Manager encountered a provisioning warning.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show log location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show log location output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_CLIENT-3-GEN_ERR_1 ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA driver encountered an Error in operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-INTERNAL_TRAP_QFULL ### Response: (Severity: 4), (Category: SNMP), (Description: SNMP agent recieves trap requests from all the sub agents on a internal queue, then the traps are classified based on several factors and passed on to different set of queues.), (Recommended Action: It is possible that huge number of traps are generated if traps are enabled for routine or simple events. Collect the show logging output, console logs, error message and trap configuration for review.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_1_SCH_MEMP_ERR_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Scheduler Hang, Sram or egress mid-fifo parity error on NPU-1 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_RIB-3-ERR_ROUTE_HDR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered in the call to ipv6_rib_batch_add_route.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL-3-CONFIG_SCAN_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An unexpected error occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-V4_OR_V6_ROUTE_OP_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: An attempt to do a v4/v6 route operation failed.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_HFR-7-ERR_HEARTBEAT_FSM_STATE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server heartbeat monitoring mechanism detected a problem in the internal state machine.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-6-CHILD_EXIT ### Response: (Severity: 6), (Category: PLATFORM), (Description: Child process exit for attach server. %d- pid of the child process.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-3-SYSCALL ### Response: (Severity: 3), (Category: OS), (Description: The client library has failed a system call.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-NOREASON_RESET ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that the node has been reset but the cause is unknown.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCMCIAD-7-MSGSEND_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to send pulse to resmgr thread to handle SIGCHLD), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture console log, 'show process pcmciad', 'show process blocked', and process core of pcmciad.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-6-INFO_UNMATCH_DIGEST ### Response: (Severity: 6), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_CONF_PRX-3-ERR_MALLOC ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error. Memory allocation failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_1_CONST_BP_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: NPU-1 is constantly backpressuring bridge instance-2.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-4-SDR_PLANE_READY_TIMEOUT ### Response: (Severity: 4), (Category: HA), (Description: SDR Plane ready is being signalled due to SDR plane ready timeout.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICYMGR-7-INIT ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-3-DBCTRL_INIT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The line card daugher board control initialization failed.), (Recommended Action: The software will try to recover by reloading the line card. Copy the error message exactly as it appears on the screen and gather the output of the CLI 'show tech-support ethernet interfaces'. If the issue persists, contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX-2-ENTER_EVENT_LOOP_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: There was an fail during PEX (PCIE Switch) driver evnet loop entry.The error message has detailed information. Entering into Event loop fail will usually result in process restart in an attempt to configure and PCIE driver event loop entry.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-SYSDB_CFG_BIND_OR_UNBIND_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that bind/unbind to config namespace in SysDB has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-4-MESSAGING_FAILED ### Response: (Severity: 4), (Category: INFRA), (Description: An error occurred while handling a request from the management thread to the data thread; the data thread was not able to respond to the management thread.), (Recommended Action: The system may recover automatically. If the problem persists, it may be possible to recover by restarting the protocol process on the affected node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_MGR-3-SYSMGR ### Response: (Severity: 3), (Category: SERVICES), (Description: The process was initialized successfully but was unable to inform System Manager of the success.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-4-WARNING_DIGEST_FILE_REINIT ### Response: (Severity: 4), (Category: SECURITY), (Description: SAM found digest file missing from NVRAM, re-init the file.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-SEM_WAIT_FAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Semaphore wait failed while waiting for signal from AIB.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists.' 'Contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_HFR-7-ERR_EVENT_CONN_OPEN ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to open connection with event manager. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-6-HA_INFO ### Response: (Severity: 6), (Category: ROUTING), (Description: Used for logging of HA events like process startup, entry and exit of NSF/GR or NSR procedures and related events.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_CHOPPER-3-Q_CREATE_ERR ### Response: (Severity: 3), (Category: L2), (Description: SPA process failed to create queue. The process will automatically respawn up to a fixed number of times to try and recover.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEPKI-6-WARNING ### Response: (Severity: 6), (Category: SECURITY), (Description: CEPKI general warning message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-6-BARBARIAN_VOLT_FIX_ACTIVE ### Response: (Severity: 6), (Category: PLATFORM), (Description: VP4 rail on the SPA is margined to nominal voltage due to SAR chip errata.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-DUPLICATE_PROCESS ### Response: (Severity: 7), (Category: HA), (Description: An attempt to exclusive-create on a local channel failed. This indicates that there's already a copy of this same process running, and it cannot be allowed to continue, since corruption can result.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-2-SDK_TABLE_FULL ### Response: (Severity: 2), (Category: PLATFORM), (Description: DPA failed to install entry because of Table Full.), (Recommended Action: Please collect the console log, DPA traces (show dpa trace loc <>), show controllers npu internaltcam location 0/0/CPU0. The failure could be because we ran out of available banks. Report to your technical support representative for further details.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-5-COMM_RESTORED ### Response: (Severity: 5), (Category: LICENSE), (Description: Smart Agent communication with the Cisco licensing service is restored.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-POLICYCONFIG ### Response: (Severity: 4), (Category: ROUTING), (Description: A problem was encountered while setting up route policy configuration. Some of the routing policy may not have been configured correctly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBIPV4-7-DATALIST_FAIL ### Response: (Severity: 7), (Category: IP), (Description: The sysdb process fails to find the address of a specified active interface or of all active interfaces.), (Recommended Action: This indicates a problem with getting the helper address. If the errors are seen continuously and you see problems with the helper address, do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the error is seen only once/twice while some sysdb processes crashed or were restarted, this might be related to that. If you don't see any issue with the helper address thereafter, it is a transitory problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-0-NO_RSP_PRESENT_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: LC is unable to detect any RSPs in the chassis.), (Recommended Action: If there indeed is no RSP present in the chassis, then this is an expected message. If RSP is plugged in and powered on, and if this message appears, then contact support team.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_SKP-7-ERR_GEN ### Response: (Severity: 7), (Category: ROUTING), (Description: MFWD-SKYWARP library encountered error during setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-INTERNAL ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal error occured in the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_MGR-3-SYSMGR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The process was initialized successfully but was unable to inform System Manager of the success.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-SRGB_ALLOC_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: An error occured while attempting to allocate the segment-routing global block (SRGB) As a result, segment-routing is not functional at all. The most likely cause of this problem is that some other application (e.g. LDP, BGP) are using labels within the global block), (Recommended Action: Verify that there are no labels used by any application within the SRGB. If, after verification that no labels are used by any application within the SRGB, the error persists, restart the isis process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_REMOVE_BULK_OP ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. This could be because the operation does not exist. The details are in the error string.), (Recommended Action: Check that the operation to remove exists. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA-7-INIT_FAILED ### Response: (Severity: 7), (Category: IP), (Description: The indicated initialization of the MPA failed and the process restarted.), (Recommended Action: If the indicated error is about low memory, do the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Else, do the following action.Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-TMB_FULL ### Response: (Severity: 3), (Category: PLATFORM), (Description: NP detects TMB_FULL and reported through interrupts), (Recommended Action: No specific actions needed. The software should be able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-BAD_VSA_LENGTH ### Response: (Severity: 3), (Category: SECURITY), (Description: VSA format error found in radiusd while translating.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-INVAL_NODEID_POWER ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the nodeid passed is not valid, and therefore the power-up request is being rejected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_EA-4-ERR_EVM_EVENT_BLOCK ### Response: (Severity: 4), (Category: L2), (Description: An error occured in the event loop. The process will restart which should recover the situation.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_SYSDB_DATALIST ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occurred while listing the contents of a directory in SysDB. This may be due to resource starvation or an internal software programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*. The IS-IS process must be restarted before it can function correctly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-6-CONTEXT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The message is for recording MPLS global context intialization event. No action is required.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-4-FSM_APPDATA ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: VPDN MGR failed process internal messages. This may be due to low memory conditions.), (Recommended Action: Allow the subscriber to reconnect. If the problem persists, contact Cisco support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VLAN_EA-3-CONFIG_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This particular configuration is not supported on this platform), (Recommended Action: Please capture the complete error log. Please check the data sheet for the supported configuration. Please contact TAC for any support on this) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-2-RX_POWER_THRESHOLD_ALERT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Rx power threshold of higher than 30 should be set only for transceivers which are 3rd party optics. For cisco CFP2 transceivers it should be less than or equal to 30.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-3-QUEUE_STUCK_STATUS_INFO ### Response: (Severity: 3), (Category: L2), (Description: Log the key asic registers when a queue stuck condition was detected.), (Recommended Action: No action is required. The driver will perform asic recovery. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-4-RX_BAD_PDU_HEADER ### Response: (Severity: 4), (Category: ROUTING), (Description: Received a bad PDU header from a peer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-SYSDB_START ### Response: (Severity: 7), (Category: INSTALL), (Description: The current operation could not start the transaction of items which are needed to activate it.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-BADDLLOPEN ### Response: (Severity: 3), (Category: MEDIA), (Description: DLL was not loaded after many retries. Will exit to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RUNTIME-6-SVC_INFO ### Response: (Severity: 6), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_SHUTDOWN ### Response: (Severity: 3), (Category: SECURITY), (Description: System shutdown.), (Recommended Action: 'SUPPORT*') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSU-4-PM_INPUT_TYPE ### Response: (Severity: 4), (Category: LIBRARY), (Description: The power module input type changed.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-MBR_BFD_NEIGHBOR_UNCONFIGURED ### Response: (Severity: 5), (Category: L2), (Description: The BFD session on the member has transitioned to NBR_CONFIG_DOWN state, indicating that the configuration has been removed from the neighbor. The member will continue to transmit packets for as long as the message specifies, at which point, if the session has not gone back UP, the member will be brought down.), (Recommended Action: To stop the member from being brought down, rectify the inconsistency between the BFD sessions of the two neighboring routers within the specified time. EITHER, configure BFD sessions per-member on both routers OR remove the configuration from both routers.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN-3-DST_REG_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The SPAN Manager was unable to obtain the information required to replicate traffic to the destinations of one or more monitor sessions. It is possible that traffic will not be replicated correctly for the affected monitor-sessions. Standard forwarding will not be affected. Use 'show monitor-session status' to identify the affected monitor sessions and to provide more information regarding the current state of the affected destinations.), (Recommended Action: This message indicates a communication problem. Attempt to resolve any memory issues before trying to solve the problem by issuing 'process restart span_mgr'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_SSE-7-ERR_SYSDB_BAG_ENCODE ### Response: (Severity: 7), (Category: L2), (Description: BFD Agent server encountered error in sysdb bag encode operation. This could affect output of some of the BFD CLI commands.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-UPD_BUFFER_SMALL ### Response: (Severity: 3), (Category: ROUTING), (Description: An allocated message did not have enough space required to format all the attributes of a prefix. When such an error encountered, a Withdraw message is generated for the prefix under consideration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an MPLS L2VPN pseudowire class? ### Response: To configure an MPLS L2VPN pseudowire class, use the 'pseudowire-class' command to define encapsulation and control word settings. pseudowire-class PW-CLASS-NAME encapsulation mpls control-word <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_LOSS_OF_OUTPUT_PWR ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-3-FWC_AVL_DELETE_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: A call into the IOS-XR AVL tree library failed. This may result in the firewall controller unexpectedly restarting after this message is seen.), (Recommended Action: If the process unexpectedly restarts, this will clear the problem; otherwise no further action is necessary to recover. In either case, please copy the message exactly as it appears on the console or in the system log, along with any subsequent messages relating to process restart and the information detailed below, and call your Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBDLLMGR-6-OVERFLOW_REPLACE ### Response: (Severity: 6), (Category: OS), (Description: An overflow encountered for the process. This is not an error.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_BRIDGE_OS ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric Bridge driver Event Manager create error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls ldp discovery hello interval' command in IOS XR? ### Response: The 'mpls ldp discovery hello interval' command is used to configure the frequency at which LDP hello messages are sent. Hello messages are used to establish and maintain LDP sessions. A lower hello interval means faster detection of topology changes and quicker LDP convergence, but also results in more LDP traffic. The hello interval should be set to a lower value than the hello holdtime. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-6-FEATURE_ACTIVATED ### Response: (Severity: 6), (Category: OS), (Description: A deactivated feature is activated.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-4-LOCAL_CORE_ISOLATION ### Response: (Severity: 4), (Category: L2), (Description: ICCP-SM has detected isolation in the core and has attempted to failover.), (Recommended Action: Use the show iccp group group-num command to determine which core facing interface has triggered the isolation failure. Correct the failure for the given interface, this will clear the ICCP-SM core isolation failure. Reference the ICCP-SM section of the IOS XR documentation for more information on core isolation failures and related configuration commands.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_EVM_ASYNC_SEND ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-3-SYSDB_GET_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The policy_repository process failed to retrieve an item from the system database.), (Recommended Action: The policy_repository process may function properly in the future but the operations associated with this configuration are likely in an inconsistent state. Consider restarting the process. If the message appears again, copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-UNKCMD ### Response: (Severity: 4), (Category: MGBL), (Description: The first token in a command string was not a recognised MDACon command.), (Recommended Action: Check the list of available commands and retry. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCMCIA-3-PCI_DEV_ATTACH_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: PCI Device is either a CARDBUS Bridge or PCI-PCMCIA Bridge. Here it cannot get PCI device information from PCI bus manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_CONFIG-7-ERR_EVENT_NOTIFY ### Response: (Severity: 7), (Category: OS), (Description: Event conn notify failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-MD5_GET_PACKAGE_SIGNATURE ### Response: (Severity: 7), (Category: INSTALL), (Description: Failed to retrieve the package MD5 from the specified package's md5_manifest file, so processing of the current operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFINDEX_PROVIDER-7-LTRACE_INIT_ERROR ### Response: (Severity: 7), (Category: SNMP), (Description: An error occured while initializing LW tracing for ifindex provider library.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-3-GET_ENET_SERVER_COID_ERR ### Response: (Severity: 3), (Category: OS), (Description: Attempt to get the enet server coid has failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-3-EAOPT_SEND_NOKEY ### Response: (Severity: 3), (Category: IP), (Description: There is no active send-key for the specified keychain and hence can't send data to the peer.), (Recommended Action: Check the keychain to see if it has any active keys. Sometimes, this error might come if there is no overlap between the send-keys. In that case, if keychain shows that there is an active key, then this error can be ignored. Else, change the configuration to have an active send-key.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-3-MEM_ALLOC_FAIL ### Response: (Severity: 3), (Category: HA), (Description: This is a generic error msg for memory allocation failure. The Process tried to allocate a memory and it wasn't succesful. Can happen when system is running low in memory), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show rsvp neighbor' command in IOS XR? ### Response: The 'show rsvp neighbor' command is used to display information about RSVP neighbors. It shows the neighbor address, the interface to the neighbor, and the encapsulation used (RSVP or RSVP-TE). This command is useful for verifying the RSVP neighbor relationships. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-3-CHECK_RESPONSE_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This error message indicates error code occured during nsg send.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-ASIC_ERR_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: The sfe-drvr process cannot initialize the infrastructure allow error capturing function for the PODs on the fabric card.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-2-XAUI_FAULT ### Response: (Severity: 2), (Category: PLATFORM), (Description: DMAC XAUI link went down and stayed down for an extended duration which would affect CE/Fabric connectivity of the RP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-3-EDM_UNREG ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to unregister EDM.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSEC_SVI_EA-3-INITFAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of the IPSec SVI EA process on a particular node. The process will be restarted. Until the process starts successfully, any IPSec SVI interfaces located on that node will not come up. (If there is a standby node the interfaces should come up on the standby).), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-3-BAGS_UNREG_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to unregister a bag.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SYSMGR_REG_REDST_FAIL ### Response: (Severity: 7), (Category: OS), (Description: Dumper registers with sysmgr for various taks. Sysmgr LR event registration failure. This will lead to unexpected behaviour from dumper.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-2-ERR_SYSDB_REGS ### Response: (Severity: 2), (Category: FABRIC), (Description: In Fabric Driver, unable to register notification of pod-err/suppress. It could be an Infra-sysdb issue OR fabric sysdb tuple name issue.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-1-BKR_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Fabric arbiter driver detected a bkr module error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-CPP_LTH_FIFO_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: IBS from CPP packet length FIFO single bit error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEPKI-6-ERR_3 ### Response: (Severity: 6), (Category: SECURITY), (Description: CEPKI general error message with three parameters.), (Recommended Action: '*SUPPORT') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_LOCAL-3-INST_NOT_FOUND ### Response: (Severity: 3), (Category: L2), (Description: This error would indicate Sonet port/path/line/section instance not found at particular line of code with function as well. This should not happen in normal scenario. This message would print reason of failure as well.), (Recommended Action: This error indicates a problem in the code and cannot be easily recovered from. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_HFR-3-EDM_REGISTER ### Response: (Severity: 3), (Category: ROUTING), (Description: The MFWD-HFR library encountered internal error during EDM oper/action setup), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHANCON-7-SVC_DEBUG ### Response: (Severity: 7), (Category: OS), (Description: A service API debug is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-3-UNSUPPORTED_USB_DEVICE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Get and set card type for use in device handling. To discover node type and set up the USB device information for that node for supported USB device. If it unable to get the USB device information, then it displays the message as unsupported device information.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-PKT_INT_ERR_AT_ILIF_1_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Packet Integrity Error at link nterface from NP/MUX on FIA), (Recommended Action: Verify correct link serdes error Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WAN_INARP-3-UNKNOWN_IFSTATE ### Response: (Severity: 3), (Category: L2), (Description: There is no action assigned to the if state change, and so nothing has been done when it was received.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WANPHY-3-FAST_TIMER ### Response: (Severity: 3), (Category: L2), (Description: An API or a function call in wanphy_proc process failed. First %s - Type of Error Second %s - Reason), (Recommended Action: If the platform doesn't support wanphy fast polling, error can be ignored. However, below command must be run before applying any other configuration: - clear configuration inconsistency) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-ERR_PRM_STATS_INIT ### Response: (Severity: 7), (Category: OS), (Description: An internal error was detected when trying to initialize a statistic counter table.), (Recommended Action: Check the status of Metro Stats Server because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-3-ADDRESS_ERROR ### Response: (Severity: 3), (Category: IP), (Description: The telnetd server was passed a bad adress.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEv2-6-PRESHARED_KEY_NOT_FOUND ### Response: (Severity: 6), (Category: SECURITY), (Description: Failed to find preshared-key.), (Recommended Action: Configure a key to keyring attached to IKEv2 profile.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_LA_QOS-2-DEVICE_HANDLE_GET_FAILED ### Response: (Severity: 2), (Category: QOS), (Description: Device handle is essential for many SDK APIs. Failed to get the device handle.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-INFO ### Response: (Severity: 7), (Category: SYSDB), (Description: The server detected an error with one of its clients.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR_ENCAP-3-SYSDB_DELETE_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The code failed to delete sysdb item while removing encapsulation config. This may be caused due to invalid arguments for which there is no current handling for the same, therefore the system may now be out of sync.), (Recommended Action: Repeat failed configuration command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-4-DSCP_EXTRACT ### Response: (Severity: 4), (Category: IP), (Description: An error occurred whilst trying to extract dscp configured value. Client will use default dscp value instead.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_EVM_EVENT_BLOCK ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: An error occured in the event loop. The process will restart which should recover the situation.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-2-ACL_DWNL_FAIL ### Response: (Severity: 2), (Category: L2), (Description: A resync with MA failed since ACL couldn't be downloaded.), (Recommended Action: No action is required. Process will be restarted in a few minutes. If not recovered, it's a fatal condition.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-RETIMER_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: The device failed, most likely reason is firmware download failed), (Recommended Action: Collect all the event logs and the output of the following commands executed from the CLI of the active RP if the asic is continuously reset and recovery does not take place after device reset: 1. 'show processes sfe_driver location ' 2. Collect all traces: 'show controller sfe trace all location ' 3. dmesg and /var/log/messages from host and sysadmin VM If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-OOM_STATE_THROTTLE ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_DIR-3-DIR_AGT_CAPI_SERVER_INIT_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: The ISSU Director's Agent module encountered an issue while attempting to set-up the ISSU Director-Agent CAPI service.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-7-RELOAD_NOTIFICATION_TEST ### Response: (Severity: 7), (Category: PLATFORM), (Description: The node received a test reload notification just to check functionality. The notification is ignored and has no impact.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSMGR-3-INST_ERR ### Response: (Severity: 3), (Category: OS), (Description: Inconsistent file count between given and in the file list.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOMAIN_SERVICES-3-EDM_SERVER ### Response: (Severity: 3), (Category: IP), (Description: Error in the domain edm server setup. EDM is used for storing and retrieval of fast changing data. Due to this error, the show commands might get impacted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ACL-6-IPACCESSLOGRP ### Response: (Severity: 6), (Category: ACL), (Description: A packet matching the log criteria for the given access list was etected.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-5-UNGRACEFUL_RESET ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: The satellite has indicated that the last time it was reset, the reset was not triggered by a user operation from the host.), (Recommended Action: If the user knows why the satellite was last reset, then no action is required. If the user wants to understand more, then the reboot reasons on the satellite should be investigated; this can be done by either logging into the satellite, or by running 'show nv satellite diagnostics satellite <> collect reset-info'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-REG_ACCESS_FAIL_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Register access failure on bridge instance-3.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-3-ERR_UNKNOWN_EVENT ### Response: (Severity: 3), (Category: FABRIC), (Description: Unknown event type received while receiving mcd msg from fsdb during FDI init.), (Recommended Action: Check for error logs from fsdb and ingressq processes. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-6-DUMP_PATH ### Response: (Severity: 6), (Category: MEDIA), (Description: Informational message indicating the nvram dump file path.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is BGP conditional route injection? ### Response: BGP conditional route injection allows a route to be injected into BGP only when another route exists in the routing table. It is configured using the bgp inject-map command which specifies a route map. The route map matches on the injected route and specifies an exist clause to match the existence of another route. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_IO-7-INIT_FAILED ### Response: (Severity: 7), (Category: IP), (Description: There was a software error during process startup.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise check whether the error code contained in the message indicates that there was a failure to allocate the necessary memory and take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If resource allocation was not the problem and it hasn't been fixed by a subsequent restart then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_CONF_PRX-6-INFO_SHUTDOWN ### Response: (Severity: 6), (Category: SECURITY), (Description: System shutdown.), (Recommended Action: 'NO ACTION') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR implement Layer 2 VPN services? ### Response: Cisco IOS XR implements Layer 2 VPN services through technologies like Any Transport over MPLS (AToM) and Virtual Private LAN Service (VPLS), enabling point-to-point and multipoint services over MPLS. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_LOS_PORTT ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_SIM-7-ERROR_RUN_BMON ### Response: (Severity: 7), (Category: MEDIA), (Description: pthread_create() returns error), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-OVERTEMP_SHUTDOWN ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC FPGA is indicating that it has detected an overtemp condition that requires the HW to be powered-off to prevent damage from over heating. Under normal condition, the IOS environmental monitoring feature should have detected increased ambient temperature and powere-off the card before the CCC FPGA internal protection kick in. But if somehow the software has crashed or not in operational state, then we could see this CCC HW protection feature kick in.), (Recommended Action: Make sure that the system is operating under recommended ambient temperature range.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-4-PSN_WRAP ### Response: (Severity: 4), (Category: FABRIC), (Description: Fabricq encountered a PCL Packet Sequence Wrap error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-CANNOT_GET_BLOB_SIZE_IN_STRUCT ### Response: (Severity: 7), (Category: INSTALL), (Description: An invalid parameter has been unexpectedly passed to the Install infrastructure. This is a coding error. The current request or operation will not be completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAN-6-DRIVER_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The particular operation mentioned in the message gave a informative message. This is not a failure.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_3_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_8_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RGMGR-3-INIT ### Response: (Severity: 3), (Category: INFRA), (Description: Initialization of RGMGR process failed to complete.), (Recommended Action: sysmgr will try to restart the RGMGR process. If it cannot be restarted it is a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-SYNC_REQUEST_TIMED_OUT ### Response: (Severity: 7), (Category: OS), (Description: When the single writer mode is set, RDS library allowes to create a ticket. RDS library got a timed out when it requested for a ticket.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_CHAN_SYNC_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-1 chan sync error on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_UV-3-EVENT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred in the main ospf_uv event loop.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_HAL-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is error message in PLATFORM FIB HAL which indicate error during buffer allocation and return the respective error code to the caller API), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show logging, show version, show platform, show install active, show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_EIO_TRAIN ### Response: (Severity: 3), (Category: FABRIC), (Description: Repeated attempts to train the EIO links between the FIA and Ingressq/Fabric ASIC has failed. No further attempts to retrain the link will be made. This is indicative of a hardware failure on the serial link between the ASICs or an inter-process communication error between the driver processes.), (Recommended Action: Collect the required information indicated below. Also, run the field diags and the health check. If the health check or diags fail, then initiate the RMA process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-2-OP_STATUS_NOT_FOUND_OR_INVALID ### Response: (Severity: 2), (Category: INFRA), (Description: The file containing operation status could not be found, or contained inconsistent information. If an install operation was previously in progress, its status is now unknown. The user should check the state of the system and perform a system reboot to recover if required.), (Recommended Action: If an install operation was in progress, reboot the system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install health-check command in IOS XR? ### Response: The 'install health-check' command performs a set of system health checks before proceeding with an installation operation. It verifies that there is enough disk space, memory, and that the configuration is consistent across nodes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-7-NOT_CONFIGURED ### Response: (Severity: 7), (Category: INFRA), (Description: ZTP is not configured to run. ZTP will exit.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMC-7-WRONG_PLANE ### Response: (Severity: 7), (Category: SYSDB), (Description: An application has tried to access a plane of SysDB data that does not exist on this node.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND_LITE_MAIN-3-TRACE_BUFF_INIT ### Response: (Severity: 3), (Category: L3), (Description: 'Trace buffer initialization failed .' 'Tracing will not be functioning properly.' 'Process will proceed running.'), (Recommended Action: 'Process restart can solve this issue.' 'If proplem persists even after process restart,' 'please collect the error log with return value' 'and core dump of the process and contact tac.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-0-ASIC_FATAL_FAULT ### Response: (Severity: 0), (Category: FABRIC), (Description: Fabric Interface Asic encountered an internal fatal fault. Card reload is the only way to recover from this error. The format string would display which of the internal fatal error resulted in this alarm.), (Recommended Action: The board would get reloaded. On reload of board, run following commands from RSP ksh to decode PCDS information - pcds_decode -c FIA <.pcds file> pcds_decode -c PFM_NODE <.pcds file>. If users has auto reset option disabled in admin config, then the board would not get reloaded on its own. At this stage collect the output of 'show asic-errors fia all location '.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX8111-2-TRANSACTION_TIMEOUT ### Response: (Severity: 2), (Category: PLATFORM), (Description: PCIE transaction timeout), (Recommended Action: This error is a momentary error and software should be able to correct it. If this error persisted for a period of 60 seconds, please perform the following actions: 1. Please check for read/write access to the attached compact flash or eUSB device by creation a temporary file. 2. If the problem still exists, please reload the board using the following command: 'reload location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure load balancing for an L2VPN bridge domain? ### Response: To configure load balancing for an L2VPN bridge domain, use the 'load-balance' command within the bridge-domain configuration. l2vpn bridge-domain BD1 load-balance flow <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HD-3-DEV_HARDDISK_RESTART ### Response: (Severity: 3), (Category: PLATFORM), (Description: Hard disk restart is taking excess time.), (Recommended Action: Please attempt to restart the hd_drv process using command: 'process restart hd_drv'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_9_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-3-PROFILE_CREATE_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The SLA Client Library received a profile that could not be created. This indicates that there was insufficient memory for creation of the profile and its associated data. Any operations configured to use this profile will not become active until the profile is successfully created.), (Recommended Action: This indicates a low-memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. The Client Library will attempt to resync itself with the Profile Manager or an immmediate resync can be attempted by reconfiguring the profile.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_SDFEC_LOM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-PROTOCOL_INVALID_MSG_TYPE ### Response: (Severity: 4), (Category: L2), (Description: The entire PDU was ignored due to an unexpected message type being received. This indicates that the last PDU sent by the peer device was not formatted correctly.), (Recommended Action: Check that E-LMI is configured on the peer device and that the link to the peer device is functionining correctly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-MUTEX_INIT_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Mutex initialization failed.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-3-FAILED ### Response: (Severity: 3), (Category: L2), (Description: - mmap failed for the following reasons * Invalid Virtual-Memory Allocations by jacket process causing SPA FAILURE * Not enough memory * The 'base_address' parameter passed to mmap is not correct - The spa might go to FAILED state on reload %s - mmap failed reason %d - maximum physical address space %x - base address), (Recommended Action: Restart the spa process, spa and LC to recover. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_SSE-3-ERR_CERR_REG ### Response: (Severity: 3), (Category: L2), (Description: BFD SSE was unable to register to component error message services. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective MSC reboot.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-3-EVT_BLOCK ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to block event), (Recommended Action: Reboot the router either manually or via Command line. If that too fails call Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_EA-3-INTERFACE_OPERATION_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The MFR EA process failed whilst trying to change interface state. The first argument is hex and shows the ifhandle.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PM-3-INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Platform Manager encountered an internal software initialization error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-3-ERR_MALLOC ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error. Memory allocation failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSI_AGENT-2-OBJ_CREATE ### Response: (Severity: 2), (Category: OS), (Description: Failed to internally create an object required to provide service.), (Recommended Action: Restart the rsi_agent process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-INVALID_64K_INPUT_SYNC_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: The 64k composite clock signal has been invalidated possibly due to loss-of-signal condition or AMI violations.), (Recommended Action: 1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 64kHz + 8kHz Japanese timing signal(defined in G.703 Appendix II.1) is applied at input port.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: An function has failed in Shelf Manager. The details are supplied in the msg.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-MEDIA_REGISTER ### Response: (Severity: 3), (Category: ROUTING), (Description: CLNS failed to register for media callback with netio during initialization. As a result, CLNS will not be able to add its caps and wont receive or send packets. It's an internal error.), (Recommended Action: Please contact cisco-support with the required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_REQUEST ### Response: (Severity: 4), (Category: L2), (Description: An error has occured processing an incoming SSRP request for the client.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.. Consider restarting the PPP MA process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_3_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Tx power less than or equal to the low Tx power alarm threshold. The QSFP+ is the pluggable optics on the line cards. The Tx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Replace the QSFP+ with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_16P_OC48-3-GET_NODEID_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLIM driver failed to obtain either its node ID or extract rack/slot/instance information (having obtained the node ID).), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_CLIENT_EVM ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA-driver Event Manager create error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRLLIB-3-DETECTED_RX_DROP_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The indicated rx pdma queue has a drop error occurred %d - device id %d - queue number %s - client name), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR_PD-3-ACTION_UNSUPPORTED ### Response: (Severity: 3), (Category: FORWARDING), (Description: The configured actions for a class-map are not supported.), (Recommended Action: Modify the policy-map to a supported configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_13_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_EVM_NOTIFY ### Response: (Severity: 7), (Category: FABRIC), (Description: Ingressq Event Manager notify error), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the ingressq driver is up and running by executing the following command at the CLI of the active RP: 'show process ingressq location < >' If it is still non-operational, enable the following debugs of the ingressq driver process: error Errors in the driver fatal Fatal errors which cause driver to exit info All informational events init Initialization events and restart the driver by executing the following command at the CLI of the active RP: 'process restart ingressq location < >' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_SHMWIN ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP local preference attribute? ### Response: The local preference attribute is used to prefer certain paths external to an AS. A path with a higher local preference is preferred. It is the second criteria in the BGP best path selection after weight. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-DUP_RTRID_AREA ### Response: (Severity: 3), (Category: ROUTING), (Description: OSPFv3 has received multiple router LSAs with our router ID.), (Recommended Action: OSPFv3 router ID must be unique. Change the router ID. Please also include the output of the additional following commands: - show ospfv3 database - show ospfv3 trace all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-6-CLOCK_CLASS_CHANGED ### Response: (Severity: 6), (Category: L2), (Description: The clock class of the advertised clock has changed.), (Recommended Action: This message is for information only, no further action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-3-CABLE_MONITOR_DISABLED ### Response: (Severity: 3), (Category: MGBL), (Description: Failure in cable monitoring function. Since this functionality is not so important in console driver, any error in this thread will be reported through syslog and thread will retire. Errors are failure in malloc or pthread operation and if such basic functions fail, then it might mean system is in bad shape. So we're not sure restarting this process will recover the situation. To avoid worst case -lose console/aux accessibility-, this process will remain without cable disconnect function. Operator might want to restart this process if this functionality is required in which this router is physically located, such as datacenter or co-location house.), (Recommended Action: If you need cable monitor functionality, please restart the process to recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_6_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-3-DB_INVALID_EPOCH ### Response: (Severity: 3), (Category: L2), (Description: An internal inconsistency was identified while performing some operation on the database. The process will attempt to recover a consistent state, and should be able to continue operating. It is possible that some parts of the dataplane may become out of sync.), (Recommended Action: If additional problems are observed then restarting the process may help to restore the system to a consistent state. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-3-RX_PKT_TLV_CHK_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: LDP received a message with a bad TLV from a peer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the lsp-mtu command in IS-IS? ### Response: The lsp-mtu command is used to configure the maximum transmission unit (MTU) size of IS-IS LSPs. By default, the LSP MTU size is 1492 bytes. If any link in the area has a reduced MTU size, the LSP MTU should be lowered on all routers in the area to prevent LSP fragmentation. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_MFWD_FRETTA-5-ERR_SYSDB_INIT ### Response: (Severity: 5), (Category: ROUTING), (Description: The MFWD-FRETTA library encountered internal error during Sysdb init setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLCTRLR-4-LOOPSTATUS ### Response: (Severity: 4), (Category: L2), (Description: A configurable controller loopback status.), (Recommended Action: No action reqiured. Msg displays loop status) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_EA-3-MEMBER_ENCAP_REMOVE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The MFR EA process failed whilst trying to remove encaps.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-EVENT_HANDLER ### Response: (Severity: 3), (Category: OS), (Description: PlaceD daemon was unable register an event handling for processing received messages, and therefore failed to initialize. Recovery occurs with automatic process restart.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_UV-6-PROCESS_NAME ### Response: (Severity: 6), (Category: ROUTING), (Description: The name chosen for the OSPF process matches an ospf show or clear command, or a command abbreviation. This can cause ambiguities with subsequent show or clear commands for this process.), (Recommended Action: Choose a different name for the OSPF process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-7-GEN_DEBUG ### Response: (Severity: 7), (Category: PLATFORM), (Description: PCIE debug information), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-6-BRM_BARRIER_SYNCED_UP ### Response: (Severity: 6), (Category: FABRIC), (Description: This message indicates that system barriers synced on this node. This message is expected during normal operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: d1qnetio-3-CHAIN_BUILDER_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The software forwarding support for IEEE802.1Q VLANs was unable to set up an interface. Software forwarding VLAN functionality on the affected node may be impaired.), (Recommended Action: It may help to restart the VLAN EA process on the affected node, with process restart vlan_ea location [location]. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-6-START ### Response: (Severity: 6), (Category: PLATFORM), (Description: It indicates that a FPD image upgrade or downgrade has started. The current image version and the upgraded image version are displayed.), (Recommended Action: This is just information to the user. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_6_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cds_proxy-3-INTERNAL ### Response: (Severity: 3), (Category: OS), (Description: The server has either failed a function that expected to succeed, or has got into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-ATTR_INIT_FAIL ### Response: (Severity: 3), (Category: SYSDB), (Description: An error occurred during initialization of sysDB pthread attribute.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOL_DEME ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-ERR_CTRACE_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: SFE driver failed to initialize ctrace buffers. However, the driver will function as normal. With no traces available for debugging.), (Recommended Action: The driver will restart and try to recover. Make sure the driver restarts and recovers. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-NO_INPUTBUF ### Response: (Severity: 6), (Category: ROUTING), (Description: This system failed to allocate an input buffer because there was insufficient memory to do so.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-EVENT_CONN_EVM_HANDLER_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: During initialization, IS-IS failed to register for input or output notifications for the specified service. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-UNLINK_NVLOG ### Response: (Severity: 4), (Category: OS), (Description: Check specified log for important information), (Recommended Action: Delete the NV_LOG file manually after copying it out of the router.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to enable MPLS LDP on an interface? ### Response: To enable MPLS LDP on an interface, use the 'mpls ldp' interface configuration command. RP/0/RSP0/CPU0:router(config)#interface GigabitEthernet0/0/0/0 RP/0/RSP0/CPU0:router(config-if)#mpls ldp <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-FGID_GET_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while getting/allocating FGID. This can occur due to - Invalid Entry handle - failed to get pre-allocated managed FGID pool), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BPE-7-ERR_LWM_EVENT_BLOCK ### Response: (Severity: 7), (Category: PLATFORM), (Description: BPE Event Manager event block error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-6-STATE_CHANGE ### Response: (Severity: 6), (Category: OS), (Description: Service state changes. They are not necessarily critical errors but need investigation by DE), (Recommended Action: Collect system logs. Collect show tech ssm. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-5-SUPP_SUCCESS ### Response: (Severity: 5), (Category: L2), (Description: Authentication was successful.), (Recommended Action: No action required (normal operation).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-BMA_OUT_OF_SEQUENCE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: EINT received an out of sequence BMA buffer request response), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SESSION_MON-4-CERR_CODE ### Response: (Severity: 4), (Category: SNMP), (Description: iedgemon encountered error and cerr code is returned), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-GO_STANDBY ### Response: (Severity: 3), (Category: ROUTING), (Description: Node role state regressed from active state to standby state. This is not currently supported by RIB.), (Recommended Action: If the node's role change from active to standby was not deliberate, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONAUX-3-CONSOLE_BLOCK_REG_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The ConAux Identity module has been unable to register the console block.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTR5 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-4-PKT_ALLOC_FAIL ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: A packet client was unable to allocate the required number of packets for transmission because no more packets are available. This may be a transient issue, if the system is under unusually heavy load, or if the situation persists it may indicate a packet client problem.), (Recommended Action: Attempt to reduce load on the system before trying the requested action again. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_13_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TYPE6-6-MASTERKEY_UPDATE ### Response: (Severity: 6), (Category: SECURITY), (Description: it show the progress of Masterkey update on system. State of masterkey set to started when update of masterkey done by admin. State of masterkey set to completed when all application complete the encryption of existing type6 data with new masterkey.), (Recommended Action: check the status of all type6 application with 'show type6 clients'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How do you activate a software package in Cisco IOS XR? ### Response: A software package is activated in Cisco IOS XR using the 'install activate' command, which enables the package's features on the router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAA-3-SYSDB_BIND_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Error while trying to bind to sysdb.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCASTSN-5-MAX_GROUP_LIMIT_REACHED ### Response: (Severity: 5), (Category: L2), (Description: The maximum number of allowed group on the bridge-domain interface has been reached. Need to reconfigure the maximun number of groups allowed or take steps to reduce groups.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-3-THREAD_POOL_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Thread pool error.This will restart dumper. After restart, dumper will recover.), (Recommended Action: Please restart the process dumper. If the issue is seen even after process restart then Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-FILE_SIZE ### Response: (Severity: 3), (Category: MGBL), (Description: Unable to add command defined under the file), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the interface preconfiguration feature in IOS XR? ### Response: The interface preconfiguration feature in IOS XR allows the configuration of an interface before the interface module or line card is inserted into the router. When the module is inserted, the pre-configured settings are automatically applied. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-PCIE_TX_FIFO_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: CIB PCIe Tx FIFO single bit error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-RIB_RETRY_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Some routes were not successfully installed in the RIB. Consequently, an attempt was made to save these routes to retry later. However, an error was encountered during the save attempt.), (Recommended Action: Issue a 'clear route
' to cause BGP routes to be reinstalled in the RIB. If this does not work, issue a soft or hard reset to all peers.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: tunnel_ea-3-STATS_INIT_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This is typically an internal error in the software. The software failed to initialize statistics infrastructure on the card where the error is seen.), (Recommended Action: If there is a problem, it might be cleared by restarting tunnel_ea. If the problem persists, copy the error message as it appears on the console and any noticeable side effects. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_COM_IFIB-7-DEBUG_CLEANUP ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when cleaning up debug. This is not a critical error, and the process can continue functioning noramlly despite this failure. Particular undebug will not be effective though.), (Recommended Action: Provide the following log: Collect Console logs and output of -show logging process pifibm_server_rp loc ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-TELEMETRY ### Response: (Severity: 4), (Category: ROUTING), (Description: Report non-successfull telemetry calls), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-6-THREAD_MUTEX_FAILED ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: NetIO was unable lock/unlock the packet mutex. This could lead to certain cases when the same packet is used), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-3-LWM_UNINITIALIZED ### Response: (Severity: 3), (Category: L2), (Description: Host side LWM is not initialized since the spa debug structure is null which doesn't have any impact as this is an informational message to the user.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REPLICATOR-3-WRITE_OWNERSHIP_FAIL ### Response: (Severity: 3), (Category: LIBRARY), (Description: The replicator has repeatedly failed to acquire ownership of a system data handle. The client process may need restarting.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_SOCKET_QUEUE_FULL ### Response: (Severity: 4), (Category: L2), (Description: The queue for storing messages to write to the TCP socket is full for the specified SSRP group. This means messages will be dropped.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the PPP MA process. *SUPPORT*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-2-STANDALONE_LEAD ### Response: (Severity: 2), (Category: TOPOLOGY), (Description: System Admin Manager has declared self as a stand alone Lead.), (Recommended Action: No action is required. More nodes will add to the cluster when they come up.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-2-ERR_SYSDB_BIND ### Response: (Severity: 2), (Category: FABRIC), (Description: In Fabric Driver, unable to bind sysdb item. It could be an Infra-sysdb issue OR fabric sysdb tuple name issue.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-5-APPS_IMAGE_DOWNLOADING ### Response: (Severity: 5), (Category: L2), (Description: Downloading SPA Application image as indicated in the message), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the properties exhibited by IOS XR software components? ### Response: IOS XR software components exhibit the following properties: 1) Functionality that can be individually developed, released, and upgraded on running systems without affecting other software components. 2) Executable code for running a process or libraries that are shared between different processes. 3) Well-identified functionality, for example ipv4-bgp, ipv4-acl, ipv4-mrib represent some of the BGP, access list, and multicast functionalities. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-6-FILE_OPER ### Response: (Severity: 6), (Category: MGBL), (Description: The TTY Server has encountered an error while opening FPD lock file. Devc-conaux has no issue to run, but FPD warning message will not be printed on AUX port during FPD upgrade.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_PW-4-ATOM_MERGE_ERR ### Response: (Severity: 4), (Category: L2), (Description: The system is configured with multiple PWs with same pw-id and with neighbor addresses that are owned by the same LDP peer. This configuration is invalid and the invalid PWs will not be established.), (Recommended Action: Remove all the PWs pointing to same neighbor and with same pw-id and re-add the one that is correct.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SD-4-WRONG_SSC ### Response: (Severity: 4), (Category: SERVICES), (Description: A Service Controller process not currently registered is sending updates from a node. The Service Director will now attempt to recover from this by resynchronising with its clients.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-FPGA_PCI_PERSISTENT_FAIL ### Response: (Severity: 3), (Category: DRIVER), (Description: IOFPGA driver was unable to recover from the PCI link failure due to a PCI FATAL erorr. IOFPGA driver has to be restarted to recover. If 5 restarts of the driver cannot recover the card will reload. If card reload cannot fix the problem it is a HW fault where something went wrong with the PCI bridge), (Recommended Action: RMA) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an L2VPN pseudowire class for encapsulation mpls? ### Response: To configure an L2VPN pseudowire class for MPLS encapsulation, use the 'pseudowire-class' command followed by encapsulation settings. pseudowire-class myPseudowireClass encapsulation mpls <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-THREAD_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: CGN_MA failed to create a thread. This thread plays an important role in sending message to CGN_EA. The process will restart under this scenario.), (Recommended Action: Try restarting the CGN process showing this error. Please contact support if the issue does not get resolved after process restart.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-ADJNSF ### Response: (Severity: 6), (Category: ROUTING), (Description: The adjacency on the INTERFACE-NAME and LEVEL with the system SYSTEM-ID STARTED responding or STOPPED responding during the NSF-restart of the SYSTEM-ID.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the BGP Distributed Speaker feature in IOS XR and what benefits does it provide? ### Response: The BGP Distributed Speaker feature allows multiple BGP speaker processes to run on different nodes (RPs or LCs) in an IOS XR system. This provides improved scalability by allowing the BGP workload to be distributed across multiple nodes. It also provides improved resiliency because a failure of one BGP speaker process does not affect the others. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2TP-3-IPC_ERR ### Response: (Severity: 3), (Category: L2), (Description: An IPC transport software error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-2-TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: The thermal sensor trip point was crossed on DMAC.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMGR-3-INCORRECT_PATH ### Response: (Severity: 3), (Category: OS), (Description: OVA path invalid), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-NETWORK_TYPE_MISMATCH ### Response: (Severity: 4), (Category: ROUTING), (Description: OSPF has received a hello packet with non-zero Designated Router field on an interface that is not a multiaccess interface. Indicates a misconfiguration of network type among the OSPF routers in the given subnet.), (Recommended Action: Check the network type on all OSPF routers in the given subnet.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_1_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB_ALARM-3-MAX_BRGMEM_ENTRY_PER_NP ### Response: (Severity: 3), (Category: PLATFORM), (Description: Exceeded maximum number of bridge ports allocated on a single NP), (Recommended Action: Reduce number of bridge ports per NP and retry) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-1-RX_OVF_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered interlaken fifo overflow error.), (Recommended Action: This fault would result in traffic loss. Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_MPLS_EA-3-INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An initialization error has occured for MPLS Forwarding Information Base.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: 10GE_PLIM-3-OIM_ERR ### Response: (Severity: 3), (Category: L2), (Description: A fatal error occurred in 10GE PLIM driver OIM rule validation.), (Recommended Action: 1. Remove the Xenpak and check if it is Cisco qualified Xenpak. 2. If it is Cisco qualified Xenpak, check DWDM Xenpak placement rule.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-QDR_M_FREE_EMPTY_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Multicast free pages empty on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_EA-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB EA, error), (Recommended Action: Please collect the console log and CLI history (show cli history detail loc <>). Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-2-LTRACE_DECODE_INIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: During ltrace decode, the decode function retrieves file names, which must be placed into a dynamically allocated array. If the allocation calls fail this warning is printed with the specific error from the system based on the return code of the allocation call.), (Recommended Action: The call only fails due to lack of memory. Wait for a short period of time (maybe a minute or two) to see if the system resource picture improves. If The problem persists, attempt to free up memory by killing unnecessary processes.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS VPN hub and spoke feature? ### Response: The MPLS VPN hub and spoke feature allows a VPN to be configured in a hub-and-spoke topology, with the hub PE router importing and exporting routes to and from spoke VPN sites. It simplifies VPN connectivity and provides a way to share services from a central site. Hub and spoke VPNs are implemented using route target import/export between hub and spoke PE routers. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-SYSDB_MC_PERF_FAIL ### Response: (Severity: 7), (Category: SYSDB), (Description: Registering for sysdb_mc histogram stats failed.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-4-DEVICE_FORMAT_FAIL ### Response: (Severity: 4), (Category: INSTALL), (Description: Selected device could not be formatted for one reason or another. Performing removal of packages and MBIs from the device to see if we can continue.), (Recommended Action: This error will be recovered automatically. No user action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-0-DAO_LINK_STATE_CHANGE ### Response: (Severity: 0), (Category: PLATFORM), (Description: The internal link interface for the specified port is down.), (Recommended Action: The board would get reloaded. On reload of board, run following commands from RSP ksh to decode PCDS information - pcds_decode -c NIANTIC <.pcds file>. If users has auto reset option disabled in admin config, then the board would not get reloaded on its own. At this stage collect the output of (admin)'show tech-support control-ethernet location file outputFile') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-5-CLEAR_CORRUPT ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: Confirmation of the number of corrupt packets cleared when 'clear packet corrupt' was executed.), (Recommended Action: Check that the number of packets reclaimed is expected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM-7-ERROR_REG_PM ### Response: (Severity: 7), (Category: MEDIA), (Description: PM_FAULT_REGISTER_DEVICE registers a device instance with the fault report API. This step must be done before the device driver may report faults. It should be done at the init phase rather than when an error occurs. When registration of device instance failed, fault reports are not logged.), (Recommended Action: Debug message only, no action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM_LIB_PD-6-BMT_MEMORY_RELEASE ### Response: (Severity: 6), (Category: L2), (Description: A failure occurred during the freeing up of the BMT. This resulted in building up of shared Memory. This will not have functional impact immediately unless Shared Memory is deprived.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-3-SESSION_LIMIT_REACHED ### Response: (Severity: 3), (Category: L2), (Description: Dot1x resource limit reached, dropping new clients.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-SATELLITE_IDENTIFIER_CHANGE ### Response: (Severity: 3), (Category: L2), (Description: A Satellite Info change notification was received for a parent interface which still had child interfaces registered.), (Recommended Action: Restarting the CFM Daemon on the node where the problem has occurred may help to resynchronize the Satellite Info. To do this issue 'process restart cfmd location ' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-6-SYSDB_NS_NODE_TO_STR_FAILED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-I2C_FAILURE_CLEAR_LED ### Response: (Severity: 3), (Category: PLATFORM), (Description: An I2C failure occurred while trying to clear one or more of the alarm card LEDs.), (Recommended Action: Try doing restarts of below process admin process restart envmon loc <>. admin process restart i2c_server loc <>. Location is from the node on which this ios_msg is seen. If the issue still persists collect required_info) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-ERR_SYSDB_DATALIST_CREATE ### Response: (Severity: 7), (Category: OS), (Description: An internal sysdb function failed.), (Recommended Action: When this issue happens, it will trigger an automatic restart. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-3-C_SHIM_QUERY_INTERNAL_FAILED ### Response: (Severity: 3), (Category: L2), (Description: Failure occured while fetching Shim information due to one of the following reasons: 1. Invalid arguments passed to function 2. Shared memory not yet initialized 3. Information pertaining to requested handle not found), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-6-COID_DISCONNECT ### Response: (Severity: 6), (Category: OS), (Description: Got a DISCONNECT PULSE. Information Message only. %d- coid %d- server coid), (Recommended Action: Informational Message only) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_SWITCH-6-UPDN ### Response: (Severity: 6), (Category: PLATFORM), (Description: A link to the RSP control plane switch has change state.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers ce-switch link detail location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers ce-switch link detail location output, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-STARTUP_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: TACACS+ process failed to startup properly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_RIB-3-DISCONNECT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during an attempt to tear down the RIB Event connnection.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-STUB_ASBR ### Response: (Severity: 4), (Category: ROUTING), (Description: Router is configured as an ASBR but is only connected to a single stub area. This can waste resources since the router has nowhere to send the external LSAs that it is generating.), (Recommended Action: Check configuration and disable redistribution of routes into OSPFv3 if appropriate.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-IFMGR ### Response: (Severity: 3), (Category: ROUTING), (Description: The specified interface manager request failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-XFP_LINE_RATE_UNSUPPORTED ### Response: (Severity: 3), (Category: L2), (Description: XFP unable to support configured line-rate; replace XFP OR change configuration.), (Recommended Action: Replace XFP OR change configuration) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-ROLLBACK_FILE_FAILURE ### Response: (Severity: 4), (Category: INSTALL), (Description: There was an error when trying to create the loadpath file for this rollback point. The operation will continue successfully (given no other errors), but this point cannot be used as a rollback point.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_BRIDGE ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA driver could not create Bridge instance.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-7-CAL_CHIP_WRITE_CMOS ### Response: (Severity: 7), (Category: MGBL), (Description: Writing value of NMI enabled flag to CMOS.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TGN-3-ERROR_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The pagent process exited due to the reason mentioned in the message.), (Recommended Action: To bring up the process , reload the LC or reinstall the pagent pie.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-3-SHM_SEGMENTS ### Response: (Severity: 3), (Category: HA), (Description: Unlink of shared memory segments failed. While initializing checkpoint.), (Recommended Action: The process shared segments are not unlinked. Process will take care of unlinking in other possible way. If the error is reported 2-3 times more . Collect system log and show tech-support and Contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GSP_EM-5-DEBUG_INIT_FAIL ### Response: (Severity: 5), (Category: PLATFORM), (Description: Debug initialization failed within EM. Debugs may not be printed), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_HFR-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Encounter problem during process initialization. '%s' contains the explanation of the problem. %s - error description %d - error code %s - error code description), (Recommended Action: Restart the fabio_svr process. Contact TAC if problem still exist) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-REMOVE_LOWMEM ### Response: (Severity: 7), (Category: OS), (Description: Memory running low), (Recommended Action: Reboot the router) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-6-CPI_PEER_FAIL ### Response: (Severity: 6), (Category: PLATFORM), (Description: Driver returned inconsistent standby RSP card presence data. This error might be observed due to a slow removal of the active RSP.), (Recommended Action: No action is required. The message is logged for informational use.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_UIDB-7-ERR_INIT ### Response: (Severity: 7), (Category: L2), (Description: Initialization of uidb_svr process has failed due to one of the following reasons: 1) Failed to create server context. 2) Failed to get schedular parameters. 3) Failed to initialize event manager. This would prevent process from receiving events. 4) Failed to register with debug. This would prevent process from logging debug messages. 5) Failed to bind UIDB server with MIPC server. This is needed to program features in hardware. 6) Failed to connect to PLIM asic processes. This is needed to program features in hardware. 7) Failed to initialize checkpoint. This is needed to checkpoint UIDB data to restore on process restart. 8) Failed to allocate, initialize and checkpoint shadow memory. This is needed to store and restore UIDB internal data. 9) Failed to get metro asic version. 10) Failed to attach event handlers needed to handle LWM messages. This is needed to enable/disable various features in hardware. 11) Various Sysdb or EDM failures 12) event_block failed. This indicates process has encountered unexpected error while waiting for events.), (Recommended Action: No action is required. Process will be restarted. If not recovered, it's a fatal condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-6-IF_OIROUT ### Response: (Severity: 6), (Category: PLATFORM), (Description: SFP or XFP or CFP or QSFP entity is removed from the line card.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-INFO ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The eint encountered an error that would lead to degraded service.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKWATCH-6-INFO_HEAD2 ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The header for resource depletion information that follows this message. It is of the format: PROGRAM_COUNTER COUNT), (Recommended Action: It is an informational message along with packet depletion log message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_MCAST-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: PLATFORM MCAST, Information), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-3-PORT_CONTROL_ENABLE_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: Failed to enable port-control on the interface.), (Recommended Action: Check the platform logs for the error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-3-THREAD_NOT_EXIST ### Response: (Severity: 3), (Category: MGBL), (Description: registry operation is failed because of corrupted data structure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_MA-3-INVALID_BW_ENTRY ### Response: (Severity: 3), (Category: QOS), (Description: The QoS MA process encountered an invalid entry while receiving updates from ANCP or Ifmgr.), (Recommended Action: Contact TAC with required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-PACKET ### Response: (Severity: 3), (Category: MGBL), (Description: The TTY Server has encountered an error using the Packet Library.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_12_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-INVALID_PARSERFILE ### Response: (Severity: 3), (Category: MGBL), (Description: 'Invalid parser file'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-4-PAK_NETIO_MUTEX_LOCK_FAILED ### Response: (Severity: 4), (Category: OS), (Description: Failed to aquire mutual lock.), (Recommended Action: Restarting netio may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_CLI-7-INVALID_ARG ### Response: (Severity: 7), (Category: HA), (Description: An argument was passed with an invalid value.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-AREANULL ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospf - show ospf trace all - show running-config router ospf - show config failed) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_9_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-0-ARBITRATION_LOCK_UNAVAILABLE ### Response: (Severity: 0), (Category: PLATFORM), (Description: Failed to grab lock in DR mode as the lock is unavailable. Possible reason: Other RP booted up in Normal mode and permanantly grabbed the lock.), (Recommended Action: Make sure that if one RP is running as DR, the other RP is not booted up in Normal mode. Both RPs should be running either in Dual mode or in Normal mode.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_AAA_SESSION_IF ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the AAA iEDGE service for the interface specified. The error message describes what operation has failed and why it failed. The most likely reason for this is that the AAA iEDGE server is unavailable. It may also be caused by low memory resource or a programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. In many cases, PPP MA will recover by itself. If it does not then restarting the process should help. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_26 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-3-ERR_PM_INIT ### Response: (Severity: 3), (Category: TOPOLOGY), (Description: System Admin Manager failed to connect to PM module.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-UNLINK_CORE_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Could not delete a file.This might impact dumper as the space will be consumed by core files which are not unlinked.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_0_TS_CORE_ERR_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: NPU-0 timestamp core error on bridge instance-3.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-DBGINIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Unable to initialize a debugging flag), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Performance Monitoring (PM) feature in Cisco IOS XR? ### Response: The Performance Monitoring (PM) feature in Cisco IOS XR allows collecting and analyzing performance statistics for various protocols and interfaces. It helps in identifying performance bottlenecks and optimizing network performance. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-NULL_PTR ### Response: (Severity: 7), (Category: INSTALL), (Description: An internal error has occurred in an application that has caused it to pass invalid data to the Package infrastructure. The current request or operation may not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-PROFILE_NOT_SUPPORT ### Response: (Severity: 4), (Category: PLATFORM), (Description: There is some configuration on the line card that originated the warning message that is not supported by the active memory resource profiles. Consult the warning message for details.), (Recommended Action: Remove all unsupported configuration from the line card that originated the warning message. Consult the warning message for details.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-CONN_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Connection to a shared database sotware component failed. This could be an intermittent issue. This can be ignored unless this message is seen frequently.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_MQ_FULL_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue full error on XAUI 1 MQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-IARM_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: protect_debug-7-DUMP_HANDLE_FTR ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ORA-7-DBGSHUTDOWN ### Response: (Severity: 7), (Category: ROUTING), (Description: The debug event shutdown failed. The ora docker will still run correctly, but debug commands may be unavailable.), (Recommended Action: Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IP_EA-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IP EA. Typically, this is an error where the software fails due to failure during forwarding feature programming. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv4 show cef ipv4 location <> show cef ipv4 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_DISC-3-SHOW_VER_INFO_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Publishing platform information to sysdb. If it fails to publish the information it displays this error.), (Recommended Action: Copy the System Message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_OPTICS_INT_PWR_SUPPLY_ALARM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-7-ASIC_ERROR_REPROG_RESOURCE ### Response: (Severity: 7), (Category: PLATFORM), (Description: An ASIC error has occured and need to reprogram resource.), (Recommended Action: An error that causes reprogram resource has happened and been handled *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to perform a system upgrade in Cisco IOS XR? ### Response: To perform a system upgrade by installing a base package, use the 'install' command in EXEC mode. RP/0/RSP0/CPU0:router#install add source tftp://server/path/to/image.iso activate <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBSOC-7-SVC_DEBUG ### Response: (Severity: 7), (Category: OS), (Description: A service API debug is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-6-FABRIC_ISOLATE ### Response: (Severity: 6), (Category: FABRIC), (Description: FIA driver received an isolate request.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-3-ASYNC_SOCKET_UNSUPPORTED_OPERATION ### Response: (Severity: 3), (Category: IP), (Description: A Linux process has attempted to send a message or connect to an async XR socket. This operation is not supported. Only standard XR TCP/UDP sockets support communication with native Linux processes.), (Recommended Action: If the Linux process which triggered this event is known, it should be prevented from trying to communicate with this XR process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-6-TEST_SKIPPED_FROM_STANDBY ### Response: (Severity: 6), (Category: DIAG), (Description: The specified test cannot be run from standby node.), (Recommended Action: Nothing. The test cannot be run but the system is working properly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TAMSVCS-3-SHOW_ERR_ERRNO ### Response: (Severity: 3), (Category: SECURITY), (Description: Generic Show TAM Error message - (Error Message - Error Description).), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-FAIL_DEBUG_REG ### Response: (Severity: 7), (Category: OS), (Description: Dumper registers with sysdb to keep various config related information.DUMPER debugging service register to sysdb failed.), (Recommended Action: Check the existence of the Sysdb service. The system is supposed to re-register if the Sysdb service is available. Collect the following data and contact support. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-5-REPARTITION_OF_EUSB_DONE ### Response: (Severity: 5), (Category: PLATFORM), (Description: Some existing eUSB may have wrong FS or partitions. Check if need to reformat the eUSB. This message will get printed if repartitioning eUSB is done for the device.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-I2C_CONN_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PM-7-INTERNAL ### Response: (Severity: 7), (Category: MGBL), (Description: The Collector has detected an internal error. Reason of the error is in the message itself. Some of the errors are self recovering.), (Recommended Action: If you see any loss of functionality try restarting pm collector and pm server process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-6-MAC_LIMIT_AC_CLEAR ### Response: (Severity: 6), (Category: L2), (Description: Number of MAC addresses in the attachment circuit has gone below the threshold of the configured maximum. If MAC learning or/and unicast flooding was disabled on the port due to MAC limit action, then it would get re-enabled automatically.), (Recommended Action: No particular action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-7-REUSING_SHM ### Response: (Severity: 7), (Category: HA), (Description: While initialising Checkpoint . Process is reusing shared memory segment because some unprocessed imdrs exist.), (Recommended Action: Debug message only. No action required. This message is to report state of process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_EVC_NOTIFY ### Response: (Severity: 4), (Category: L2), (Description: During initialization, PPP MA failed to register for essential notifications regarding the state of the connection for the specified service. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-bandwidth collect frequency feature? ### Response: The MPLS TE auto-bandwidth collect frequency feature specifies how often auto-bandwidth measures the output rate of a tunnel before making a bandwidth adjustment. A higher frequency means auto-bandwidth reacts more quickly to traffic changes, while a lower frequency means bandwidth adjustments occur less often. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-BADTIMER ### Response: (Severity: 3), (Category: ROUTING), (Description: A timer was found with an unrecognized type), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_CPP_MCAST_GTRIE-4-INIT_WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: Error while initializing Gtrie. Initialization will continue), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install commit command in IOS XR? ### Response: The 'install commit' command makes the current active software packages persistent across reloads. Without this command, the router would revert to the previously committed software set after a reload. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XCVR-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message from the XCVR. Evaluate whether transceiver should be enabled or disabled. Unsupported transceivers are allowed as long as we have no other reason to disable them. Security has failed, the identification and compatibility information may be incorrect; ignore them.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-7-ERR_PCDS_SUPPORT ### Response: (Severity: 7), (Category: FABRIC), (Description: PCDS support will not be available due to the specified reason.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-0-PEX_FATAL_ERR_BIT ### Response: (Severity: 0), (Category: PLATFORM), (Description: Device driver detected a pex switch error), (Recommended Action: Please try to correct problem by reloading board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ERR_THREAD_MUTEX_UNLOCK ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to unlock a mutex failed. The error is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message provides information about the kind of events happening in the software at the location where the error is seen. This is not an error message. Typically, following events are logged in this message type. - End of successfull initialization of the software. - Start and end of a processing of new object that needs to programmed to the hardware. - Configuration is not applicable to the port.), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-ENCAP_CHANGE ### Response: (Severity: 4), (Category: L2), (Description: Set: CFM PDUs cannot be sent from the interface mentioned in the message, for one of the following reasons: - The interface has no encapsulation configured. - The interface has a complex encapsulation configured, which is not supported in conjunction with CFM. Complex encapsulations include: - Matching on source or destination MAC addresses - Matching on payload ethertype - Matching on VLAN tags using the 'any' keyword. In these cases, it cannot be determined how to format the Ethernet header for sending CFM PDUs, and hence CFM is not supported in these scenarios. - The interface encapsulation is such that more than 2 VLAN tags are needed. Clear: the error condition no longer holds; either a supported encapsulation has been configured and CFM PDUs can be sent, or all CFM Maintenance Points have been removed and CFM PDUs no longer need to be sent.), (Recommended Action: Either configure a supported encapsulation on the interface, without using the above types of 'complex' matching criteria, or deconfigure any CFM MPs on the interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPU_PKT_F3_MBE ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPU packet FIFO 3 multiple bits error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-INTERFACE_MANAGER_CONNECT_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: An error was encountered while the specified process was initializing. The error message contains details about the source of the error. Frequency synchronization on this line card is disabled.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-NETWORK_TYPE_MISMATCH ### Response: (Severity: 4), (Category: ROUTING), (Description: OSPFv3 has received a hello packet with non-zero Designated Router field on an interface that is not a multiaccess interface. Indicates a misconfiguration of network type among the OSPFv3 routers in the given subnet.), (Recommended Action: Check the network type on all OSPFv3 routers in the given subnet.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-RELOAD_DENIED ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates that requested node cannot be reloaded because its in UNPOWERED (admin-config power-disabled) state or not ready for reload operation.), (Recommended Action: Remove node's power-disable config via CLI and then try again: (admin-config)#no hw-module power disable loc <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-2-NSR_TRIGGER_FO ### Response: (Severity: 2), (Category: ROUTING), (Description: If nsr switch-over knob is on, active bgp will trigger the switch over in case of tcp failure or bgp failure if nsr is ready and install is not in process.), (Recommended Action: This msg is info only. Analysis should be done if switch-over is not expected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_3_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_3 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-5-SECURITY_MAC_SECURE_VIOLATION_AC ### Response: (Severity: 5), (Category: L2), (Description: The MAC secure in attachment circuit has detected violated packet. This might be a security attack. A relearn attempt had been made on the attachment circuit for a MAC address which had been already learned by another secure port. One of following action might be configured and will be taken on this attachment circuit: - Restrict: drop the packet and disable the learn attempt - None: forward the packet and allow the MAC to be relearned - Shutdown: shutdown the port on which the learn attempt was made If no action has been configured, the restrict action will be taken by default and packet has been dropped.), (Recommended Action: Fix the root cause of the mac security action and use l2vpn clear command to bring back this port; ( clear l2vpn bridge-domain ).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_PFI-3-NODEID_CREATE_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Platform PFI was unable to create node id instance. The returned error code should indicate the reason for the failure of the api. This is a transient error in the system likely due to some config events. The client logging this error should retry the api and/or handle this error accordingly. If this error is seen persistently, Initiate the recommended action.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: IOS XRv reddrv error message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-6-UP_REV ### Response: (Severity: 6), (Category: PLATFORM), (Description: For displaying severely up-rev notification.), (Recommended Action: tech support should be contacted for downgrade instructions) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_EVC_CLOSE ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA failed to close a connection to an essential service. This is an internal error and it requires a restart of the process for recovery.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_BAD_PDU_FORMAT ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS has received a PDU containing a format error. This indicates that the system which built the PDU is not conforming to the protocol specification. In most cases this is the neighbor, but in the case of LSPs it is the system which generated the LSP. The message contains the type of the PDU, the interface it was received over (and, in the case of a LAN interface, the SNPA), and a description of the format error. IS-IS will not use any of the information contained in this PDU. In the case of an LSP, IS-IS will not flood the LSP to neighbors.), (Recommended Action: Identify the source of the offending packet and correct it. If the message recurs 'debug isis packet-errors detail' may be used to provide a dump of the problematic PDU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR-7-ERR_THREAD_MUTEX_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while creating a mutex for use by a client with the specified ID. This is crucial for the process and is automatically restarted on this failure.), (Recommended Action: If the problem is experienced only by this process in the system, restart the fabric server process by executing the following command at the CLI of the active RP: process restart fab_svr location If problem either persists (following a process restart) or also noticed on other processes then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TAMSVCS-2-TPM_DB_CORRUPT ### Response: (Severity: 2), (Category: SECURITY), (Description: TAM detected a change in master key or corruption of TAM database/master-file. Cleaning up to restore TAM functionality.), (Recommended Action: Master key used to decrypt secure storage on this card has changed or is corrupt. Hence secure objects cannot be retrieved or stored. As a mitigation, secure object datatbase is deleted and recreated.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-IPV6_LAS ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occurred while IS-IS was using the IPv6 Local Address Consumer Service.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rewrite-4-LOST_EVENT ### Response: (Severity: 4), (Category: L2), (Description: Rewrite Helper failed to receive an event that was sent to it.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPC_I2C-7-BUS_UNHANG_SUCCESS ### Response: (Severity: 7), (Category: PLATFORM), (Description: The I2C bus hang has been cleared successfully. I2C communication is restored on the bus.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_L2FIB-2-ELAN_MACEXTTABLE_CLEAR_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Failed to clear the elan mac collision table in L2FIB PD component.), (Recommended Action: Please unconfigure and reconfigure L2VPN to recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-SUDI_AUTH_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: SUDI authentication failed for indicated card/chassis during init.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-3-INIT_ERROR_MSG ### Response: (Severity: 3), (Category: L2), (Description: This is a debug message in the NPU Driver to indicate an operation or condition.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-3-PORT_ERR ### Response: (Severity: 3), (Category: IP), (Description: A port up/down message was received but the operation failed.), (Recommended Action: If the error was the result of a get operation for a port down event, perhaps a port up was never received or a clear operation was performed on an unconfigured ANCP port circuit. If the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation, look to see if there are other system messages which can provide more clues to the problem. If there are no other messages, please take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_STAT_VEC_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-0 state error on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_IPV4_EA-3-ERROR1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: DNX IPV4-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-ATTRKEY_INCONSISTENT ### Response: (Severity: 4), (Category: ROUTING), (Description: The attribute key generation routine has gone beyond the checkpointed value. This is a rare condition to occur as the key generation algorithm is very simple.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB_API-3-GENINITFAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Error occurred at client initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-RPF_REDIRECT_DROP ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-6-CHAN_CONNECT ### Response: (Severity: 6), (Category: L2), (Description: The channel connection for sending messages and pulses is failed), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TOPAZ_PFI-3-SET_GLOBALS_FTRUNCATE_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Platform PFI was unable to truncate the file. The returned err code should indicate the reason for the failure of the api. This is likely due to a transient condition on the system. The client calling this api could retry it or handle it accordingly. If the issue is seen persistently, initiate the recommended action.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBIMGR-7-IMAGE_VALIDATED ### Response: (Severity: 7), (Category: PLATFORM), (Description: A message to indicate which MBI was validated for which location.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-6-INVALID_TTY ### Response: (Severity: 6), (Category: MGMT), (Description: This comes when trying to run console program on non-console/non-aux), (Recommended Action: 'Debug message only. No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of OSPF authentication and how is it configured? ### Response: OSPF authentication is used to ensure that OSPF packets received are from trusted sources. It prevents unauthorized or malicious routers from injecting false routing information into the network. OSPF supports plain text and MD5 authentication. Authentication is configured per area or per interface using the 'authentication' and 'authentication-key' commands under the OSPF process or interface configuration mode. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_8_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-BRINGDOWN_REQUEST_RCVD ### Response: (Severity: 4), (Category: PLATFORM), (Description: This msg means that shelfmgr is shutting down a node because a process specifically requested it.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-BADCLASS ### Response: (Severity: 7), (Category: MGBL), (Description: An invalid class name was entered either by itself or as part of a hierarchy string.), (Recommended Action: Use the classinfo command to get more information about available class names. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-ERR_SYSDB_DATALIST_NEXT ### Response: (Severity: 3), (Category: MGBL), (Description: 'The sysdb operation failed. Error text is displayed in the message'), (Recommended Action: Unexpected failure happened while reading data from sysdb datastore. This could affect parser from parsing some commands. Please collect the console log, show logging output, any other messages related to system database, and unexpected syntax error failure in some commands if any noticed. And call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-ACP_IPSEC_TO_NBR_REMOVED ### Response: (Severity: 6), (Category: SERVICES), (Description: 'Autonomic Network Control plane - IPSEC tunnel ' 'to neighbor is removed'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FC-6-FWFILE_INFO ### Response: (Severity: 6), (Category: INSTALL), (Description: Information about the firmware file that is impacted by the install), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDIO-7-OPERATION_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-2-CRS_X_MSC_POWERUP_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: MSC-400G board power up failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_0_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_0 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show mpls ldp bindings' command in IOS XR? ### Response: The 'show mpls ldp bindings' command is used to display the LDP label bindings. It shows the prefix, the local label assigned by the router, the remote label learned from the LDP peer, and the peer ID. This command is useful for verifying that labels are correctly assigned and exchanged between LDP peers. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-SET_VTX_ROMVAR_STRING ### Response: (Severity: 3), (Category: OS), (Description: Failed to set ENABLE_VTX rom monitor variable due to invalid string format.), (Recommended Action: Verify format of string from error message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_TF_INTR_FIFO_1HI_EXT_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_TF_INTR_FIFO_1HI_EXT_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-3-ERR_GSP ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID-DB server encountered the annunciated GSP error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE flooding threshold up/down feature? ### Response: The MPLS TE flooding threshold up/down feature allows the control of when link bandwidth changes are flooded as a result of bandwidth increases or decreases. Flooding can be triggered when the bandwidth crosses user-defined up or down thresholds specified as a percentage of the link capacity. This reduces the frequency of TE flooding due to bandwidth changes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XCVR-3-DEBUG_REGISTER_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message from the XCVR stating that registering with sysdb fails.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2TP-3-ERRMSG ### Response: (Severity: 3), (Category: L2), (Description: An internal software error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_SERDES_3_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data serdes link 3 failure on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-LSP_PREEMPT ### Response: (Severity: 5), (Category: ROUTING), (Description: The specified interface, with specified LSP Id, has been preempted \ at specified IP Address or local node. The first %s refers to \ signalled tunnel name and the second %s refers to either \ the IP Address (of the remote node) or 'local node'.), (Recommended Action: None. This is a solicited message (by 'logging events preemption' \ configuration). User may verify reservable bandwidth on remote or \ local node as specified by the message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-MLACP_ITEM_PEER_MISCONFIGURATION ### Response: (Severity: 5), (Category: L2), (Description: If there is a misconfiguration for an item that may be resolved without user intervention, then the item and its children will be temporarily ignored. Once the misconfiguration is resolved, either by a resync of mLACP data or by the user, the item will no longer be ignored. Note that peer data which is rejected will be deleted from the local database so the information which caused the issue may not be visible in show commands.), (Recommended Action: Check show mlacp after a short while to see if the problem has cleared and all expected items are present. If the problem does not clear, ensure that the configuration (on both local and peer device) is as expected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CMPP-4-ERR_EVC_OPEN ### Response: (Severity: 4), (Category: INFRA), (Description: CMPP failed to open a connection to an essential service during initialization. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-CARD_POWER_OFF_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Power off operation on the indicated card has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SDAC_CTRL-4-MODE_CHANGE_REBOOT ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: This indicates that the router has detected that it should operate in NV Satellite mode. This requires a reboot, which will happen automatically.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB_LIB-3-L2FIB_API_ERR ### Response: (Severity: 3), (Category: L2), (Description: This error could have occurred due to specifying invalid object), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-QDR_MEM_SELFTEST_FAIL_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: QDR memory self test failure on bridge instance-1.), (Recommended Action: Please reload the board using the command 'reload location <>'. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SDS-3-PKG_MEM_CACHE ### Response: (Severity: 3), (Category: INSTALL), (Description: An error occurred while the packages were being cached to memory.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-1-ALERT ### Response: (Severity: 1), (Category: PKT_INFRA), (Description: An alert error has been detected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-TX_ALARM_TPDV_SYNC_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: In T1 mode TPDV alarm is raised when the transmit data stream does not meet ANSI T1.403 requirements for transmit pulse density.), (Recommended Action: Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-7-GENERIC_ERROR ### Response: (Severity: 7), (Category: SECURITY), (Description: Error message for internal debugging purposes.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_0_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Tx power less than or equal to the low Tx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Tx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Replace the QSFP+ with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-0-SEM_UNCORR_ERR ### Response: (Severity: 0), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered uncorrectable error. Reloading LC to recover), (Recommended Action: Ensure FPGA version is latest. Contact support if the error is persistent. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOMAIN_SYNC-3-SYSDB_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Could not bind to or register to sysdb), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAMSG-3-DEBUG_REGISTER_FAILED ### Response: (Severity: 3), (Category: L2), (Description: SPA related error msg which indicates registering with sysdb fails), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-NSR_UNRECOGNIZED_PATH_INFO ### Response: (Severity: 4), (Category: ROUTING), (Description: A path with unrecognized flags has been synchronized to standby RP during NSR synchronization for a net. This may result in inconsistent state between active and standby BGP which may impact operation after RP switchover.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-7-INVFREE ### Response: (Severity: 7), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE5_LANE_CRC_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE5_LANE_CRC_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-6-ACCTRC64B ### Response: (Severity: 6), (Category: L2), (Description: A CPP access was traced), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB_API-4-PROC_EXIT ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal message), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-LICENSE_POOL_REMOVED ### Response: (Severity: 4), (Category: LICENSE), (Description: The license database contained a license pool definition for an SDR that does not exist. The licenses assigned to this pool were automatically moved back into the Owner pool.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WATCHDOG-3-UNEXPECTED_EXIT ### Response: (Severity: 3), (Category: INFRA), (Description: Watchdog monitoring service exited unexpectedly. Card will reload if the system is unable to correct this condition on its own.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-4-PCI_LATCH ### Response: (Severity: 4), (Category: PLATFORM), (Description: Error was observed on the system PCI bus. Error description is provided.), (Recommended Action: Check if there are any asic errors or asic drivers restarts observed around this error. Check if process 'pci_bus_mgr' is up and runnning. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-ERR_EVM_INIT ### Response: (Severity: 7), (Category: OS), (Description: An internal error was detected when trying to set up event connection.), (Recommended Action: When this issue happens, it will trigger an automatic restart. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-NPL_TIMEOUT ### Response: (Severity: 3), (Category: ROUTING), (Description: A message is dropped in the NPL queue - this triggers NSR resynchronization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_0_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_MEAS-5-SR_POLICY_BURST_INTERVAL_STRETCHING_INACTIVE ### Response: (Severity: 5), (Category: ROUTING), (Description: The condition triggering the SR_POLICY_BURST_INTERVAL_STRECTHING_ACTIVE syslog has been cleared. SR Policy delay measurement sessions now run using their configured burst interval.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_SERDES_1_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data serdes link 1 failure on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SECURE_VAULT-6-CORE_STOP ### Response: (Severity: 6), (Category: SECURITY), (Description: The Secure Vault process has been disabled and the core elements have been stopped successfully.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_NEXTHOP_REGISTER ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process failed unexpectedly to register a next-hop resolution event. Future state change events on the next-hop may cause further messages to be generated by the static process.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_CHAN_SYNC_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-0 chan sync error on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different ways to filter BGP routes on IOS? ### Response: BGP routes can be filtered on IOS using\n- AS path access lists to filter based on AS path\n- Distribute lists to filter based on prefix\n- Prefix lists to filter based on prefix\n- Route maps to apply complex filtering logic\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you verify the installed packages after booting an IOS XR router with a .vm composite image? ### Response: After booting an IOS XR router with a .vm composite image, you can verify the installed packages using the 'show install active summary' command in admin mode. This will display a summary of the active packages on the router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSA-6-LC_STATE_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that Linecard is successfully up and operational data from device can be fetched), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ET1_INTR_HDR_CSUM_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ET1_INTR_HDR_CSUM_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DCL_LIB-4-UNEXPECTED ### Response: (Severity: 4), (Category: HA), (Description: An unexpected condition was encountered. This is not necessarily an error, but information gathered here may help with debugging other problems elsewhere in the system.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-2-ASIC_ERROR_PON_RESET ### Response: (Severity: 2), (Category: PLATFORM), (Description: An ASIC error has occured and power on reset is needed), (Recommended Action: An error has happen and PON reset has been performed to recover. Collect required information and contact TAC *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TEMPERATURE_ALARM-3-DIE_OVERTEMP_YELLOW_MINOR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Hotspot temperature sensor is risen above or fallen below configured yellow threshold.), (Recommended Action: *SH_CMD show env*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-5-CORE_TRANSFER_STATUS ### Response: (Severity: 5), (Category: OS), (Description: Dumper transfers core file to a persistant location(configured paths) after the core dump is successfull to /tmp/dumper. Status of the core dump transfer to persistent location.), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE link-management timers feature? ### Response: The MPLS TE link-management timers feature allows the configuration of timers to control the frequency of TE link state advertisements and processing. The periodic-flooding timer controls how often TE LSAs are flooded even without changes. The periodic-flooding threshold controls by how much bandwidth must change to trigger immediate flooding. The degraded-interval timer controls how often TE metrics are recalculated on degraded links. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_LOSS_OF_LOCK ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_EA_MODIFY-3-FAILED ### Response: (Severity: 3), (Category: QOS), (Description: The QoS policy on the interface specified could not be modified successfully in response to an ANCP or interface speed change notification. This may happen because the QoS policy is now invalid with the new reference bandwidth.), (Recommended Action: Verify the bandwidth values. Remove the qos policy and reattach. Fix errors in the policy, if any.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EEM-7-ACTION_SYSLOG_LOG_DEBUG ### Response: (Severity: 7), (Category: HA), (Description: The action_syslog call from tcl script.), (Recommended Action: Please verify command(s) mentioned in tcl script prior to error message are working fine (on router prompt). If issue is still seen then please provide command details which has resulted into this error condition to technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-7-ERR_RECV_TE_MSG_VERSION ### Response: (Severity: 7), (Category: ROUTING), (Description: The process has received a TE message with an incompatible version. As a result, the TE message is ignored and TE tunnel may not come up.), (Recommended Action: Collect output from 'show tech-support mpls traffic-eng'. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-DEBUG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Error encountered in debug module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_EXMEM-3-EXTRL_MEM_MGR_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: Exiting the process because of failure in CPP external memory manager.), (Recommended Action: *SH_CMD show controllers pse qfp infrastructure exmem statistics location < >*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-7-CAL_CHIP_PRINT_TIME_VAL ### Response: (Severity: 7), (Category: MGBL), (Description: Printing value of time in sec:min:hour:day:month:year.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-MGMT_UNEXPECTED ### Response: (Severity: 3), (Category: MGBL), (Description: The TTY Management Commands Process has encountered an unexpected error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-3-INSTALL_DEVICE_UNAVAILABLE ### Response: (Severity: 3), (Category: INSTALL), (Description: Insthelper on non-dSC management nodes requires the same install device as instdir's install device on dSC. However, after waiting for some time, the required install device did not become ready. If it was a managed node, then its bootflash device is not available.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CSI_EA-3-TIMER_ERR ### Response: (Severity: 3), (Category: L2), (Description: This is an informational message in the CSI EA to indicate that an error was seen in timer operation), (Recommended Action: Please collect the trace,) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: G8032-4-INIT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: An error was encountered while the specified process was initializing. The error message contains details about the source of the error.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-EXIT_DRVR ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA driver process is exiting due to the mentioned error condition.), (Recommended Action: Verify that the driver will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-4-CHKPT_CREATE ### Response: (Severity: 4), (Category: ROUTING), (Description: The MRIB encountered error while creating check point record along with key.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS_MODULE-2-DEV_OPTICS_PID_NOT_SUPPORTED ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PID not supported error was detected during optics initialization. A PID not support error is reported when either the PID can not be read or not supported on the platform. The optics is the pluggable optics on the line cards.Optics initialization may happen when linecard boots up, optics OIR and line card process restart. The optics will not be enabled if a PID not supported error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the optics with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_EA-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB EA, error information), (Recommended Action: Please collect the console log and CLI history (show cli history detail loc <>). Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHANCON-4-SVC_WARNING ### Response: (Severity: 4), (Category: OS), (Description: A service API warning is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INFRA_TEST-3-UNSOLICITED_1 ### Response: (Severity: 3), (Category: TEST), (Description: An unsolicited message with a string arg and an integer arg and an interface.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-BPARAMS_UPDATE_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error in boot parameters reception occurred in Services PLIM. Cause of the error will be mentioned in the message displayed. This error blocks Application Launch on Services PLIM.), (Recommended Action: Do warm reload of Services PLIM MSC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-0-PEX_INT_VS0_BIT ### Response: (Severity: 0), (Category: PLATFORM), (Description: Device driver detected a pex switch error), (Recommended Action: Please try to correct problem by reloading board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR-3-EA_PLATFORM ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates a failure in platform programming.), (Recommended Action: An error may have occurred in the hardware or lower layer processes. Please collect the information specified in required_info section and contact Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-INTERFACE_QUERY_ERROR ### Response: (Severity: 4), (Category: INFRA), (Description: After an interface was learnt about by XLNCd, a netlink query was made to get the attributes for the interface. However, this failed, meaning any attribute information about that interface won't be sync'ed from linux to XR), (Recommended Action: If the problem persists, try a process restart, If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ED_SCH_INTR_UC_QTYPE_HANG_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ED_SCH_INTR_UC_QTYPE_HANG interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-MDIO_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: MDIO read/write failure/success for the given port.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-7-GENERIC_ERROR ### Response: (Severity: 7), (Category: SECURITY), (Description: Generic error message used for internal debugging.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-INFO_LOG ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an information log.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND_LITE-3-SHMEM_GIP_UNAVAILABLE ### Response: (Severity: 3), (Category: L3), (Description: The IPv6 Neighbor Discovery (ND) spoofing process (ipv6nd_lite) has been asked to handle more global-scope IPv6 addresses than it is built to support. This error alone will not prevent the router from working, but since ipv6nd_lite is used to maintain service during restarts of ipv6_nd, it may cause the router to become momentarily unreachable by other routers during restart. The error may result from a misconfiguration, or by being deployed in an environment with unexpectedly large numbers of neighbors.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-IDB_VERIFY_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp global-interface command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp global-interface output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp interface command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp interface output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace im error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace im error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-IF_CREATE ### Response: (Severity: 3), (Category: FORWARDING), (Description: An error was encountered in creating the interface for the specified tunnel.), (Recommended Action: Remove and reconfigure the tunnel which is failed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_AAA_ATTR_IF ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the AAA attribute service for the interface specified. The error message describes what operation has failed and why it failed. The most likely reason for this is low memory resource or a programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. In many cases, PPP MA will recover by itself. If it does not then restarting the process should help. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_PM_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Satellite PM Failure (SAT_PM_FAIL) alarm is raised when there is a faulty power-supply assembly.), (Recommended Action: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATMGCMGR-2-INIT ### Response: (Severity: 2), (Category: L2), (Description: A failure occurred during the initialization of the process. This resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EM-7-EEMED_EI_EVENT ### Response: (Severity: 7), (Category: HA), (Description: The event detector has failed to initialize the sigevent structure to be used by the Event Manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-MTD_FORMAT_FAILED ### Response: (Severity: 3), (Category: DRIVER), (Description: The host is reporting a failure while trying to format MTD device on the card. The MTD device is formatted once when it first boot IOS XR, but it can also get formmated trying to recover from failure to access the device.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_FPD-3-SW_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An internal software error has occurred on the specified SPA.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-RX_ALARM_AIS_SYNC_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: The BITS receiver has detected AIS defect for incoming signal. AIS is usually an unframed all-ones signal. For T1 mode AIS is declared when the BITS receiver detects four or fewer zeroes in a 3ms period. For E1 mode AIS is declared when the BITS receiver detects fewer than three zeroes in two E1 frames.), (Recommended Action: 1) Ensure framing format on port matches framing format on the line. 2) Trace and check the source of AIS signal. Possibly an incorrect internal configuration in the service provider equipment, or a failure in their upstream connections.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-DENY_IN_ACL_NOT_SUPPORTED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Deny' action for an ACE is not supported and will be ignored. The behavior will be the same as with Permit action.), (Recommended Action: If the behavior is not acceptable, remove the Qos policy from the interface, otherwise no further action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_1_SCH_MEMP_ERR_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Scheduler Hang, Sram or egress mid-fifo parity error on NPU-1 interface on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How do you enable BGP graceful restart in IOS XR? ### Response: BGP graceful restart is enabled in IOS XR to maintain forwarding during BGP restarts and to signal this capability to peers. router bgp 65000 graceful-restart commit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYNCFS2-7-MUTEX_TEST_LOCK ### Response: (Severity: 7), (Category: MEDIA), (Description: A mutex which should have been locked was tested and found unlocked), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_DBG-3-ERR_DEBUG_LOG ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error information during debug initialization in platform FIB), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6-3-NULL_HANDLE_ALLOC ### Response: (Severity: 3), (Category: IP), (Description: Handle allocated by port arbitrator is invalid. This might be because the system is low in memory.), (Recommended Action: Check if there are any possible memory leaks.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBCORE-3-BAG ### Response: (Severity: 3), (Category: SNMP), (Description: A problem occurred while doing following operations from a bag. - Encoding information from bag - Decoding information from bag), (Recommended Action: Check for memory usage, this is a very corner case) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PA_FF-4-GET_NODEID ### Response: (Severity: 4), (Category: OS), (Description: A call to platform_get_my_nodeid faild.), (Recommended Action: Collect the system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-OVERTEMP_AMBIENT_INRESET ### Response: (Severity: 2), (Category: PLATFORM), (Description: Do not insert A9K-NP300-LC on V1 Fantray system. Upgrade to V2 FT and then insert A9K-NP300-LC. For internal testing with ROMMON variable, it is allowed to boot-up. But in case of Inlet temp more than 35.0C, all A9K-NP300-LCs will be put in IN-RESET state. Software won't take any further action after this.), (Recommended Action: Upgrade to V2 Fantray immediately and do not power on A9K-NP300-LC again without upgrading Fan) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR_ENCAP-3-SYSDB_CREATE_SET_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The code failed to create sysdb item while applying encapsulation config. This may be caused due to invalid arguments for which there is no current handling for the same, therefore the system may now be out of sync.), (Recommended Action: Repeat failed configuration command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-UNSUPP_TX_CH ### Response: (Severity: 3), (Category: FABRIC), (Description: The Tx POD detects an unknown error on a channel. The channel might not be functioning properly, and can cause cell drops, or corruption from received cells. There can also be a software bug such that the error is not handled), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-7-ERR_CHKPT_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: The FIA driver failed to initialize the checkpoint library. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-ENS_WRITE ### Response: (Severity: 3), (Category: OS), (Description: ens_write call has failed. This call may be failed due to underneath transport issue.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-7-ERR_LWM_EVENT_BLOCK ### Response: (Severity: 7), (Category: PLATFORM), (Description: Cpuctrl Event Manager event block error), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the 'show tech-support' command in troubleshooting Cisco IOS XR? ### Response: The 'show tech-support' command in Cisco IOS XR generates a comprehensive report containing various system information, configuration details, and diagnostic data. This report can be used by Cisco technical support for troubleshooting complex issues and identifying potential problems. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_DPM-6-DISCOVERY_CHAIN_DOWN ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The Discovery protocol requires a connection to a satellite - either direct, or through a chain of satellites. If a link is identified to have gone down, then all satellites on the far side will be undiscovered.), (Recommended Action: If making transport layer changes or re-configuring the satellite, then this syslog is probably expected and purely informational, so no further action is required. If unexpected, then check the transport layer between the host and the satellite and ensure that the satellite is working as expected. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-MSG_CHAN_DISCONN ### Response: (Severity: 7), (Category: HA), (Description: An internal error was detected when trying to disconnect a message channel.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-SRC_UPDATE_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_CHOPPER-3-SOFTWARE_PARAM_ERR ### Response: (Severity: 3), (Category: L2), (Description: SPA process failed due to internal software error. The process will automatically respawn up to a fixed number of times to try and recover.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSVP-3-CHKPT_XFORM_INVALID_DIR ### Response: (Severity: 3), (Category: ROUTING), (Description: The RSVP checkpoint table translation library was invoked with an invalid translation direction.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-5-IN_COMPLIANCE ### Response: (Severity: 5), (Category: LICENSE), (Description: All customer requested entitlements are authorized by Cisco licensing service.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-SEARCH_HDLS_FAILED ### Response: (Severity: 7), (Category: OS), (Description: nrs_search for the specified replica did not yield any data handles.), (Recommended Action: If this message is seen for a particular process on a particular node more than 5 times then contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: aaa_task-3-INVALID_AAA_TASK_DEBUG_FLAG ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_EEC1 ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from EEC1.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-INIT_SYSDB_CONNECT_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failed to connect with sysdb. Failed to connect to pfilter_ea_clr_edm_init()), (Recommended Action: A process will be initiated by the software. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If restart din't fix the problem) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-3-DSC_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The dsc process failed in initialization becasue of the error during initialization.The process will respawn itself.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the dsc process is up and running by executing the following command at the CLI of the active RP: 'show process dsc' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-6-SYSDB_BLOCK_RECOVER_WAIT ### Response: (Severity: 6), (Category: OS), (Description: SSM process is waiting for sysdb service(s) become available.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-PENDING_MSG ### Response: (Severity: 7), (Category: OS), (Description: couldnt create pending msg for the incoming write/publish.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-3-ERR_IPV4_REGISTRATION ### Response: (Severity: 3), (Category: L2), (Description: CDP registration with the IP address library has failed. This means that IPv4 address information for interfaces local to this node will not be included in outgoing CDP packets. The neighboring devices will not see the IPv4 address information for this router's interfaces.), (Recommended Action: Restarting CDP as the address consumer, or the ipv4_ma as the address provider on this node may rectify the problem. proc restart cdp location or proc restart ipv4_ma location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-ACTION_BEGIN ### Response: (Severity: 6), (Category: INFRA), (Description: A user requested install operation has begun.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-4-DOUBLE_CLOSE ### Response: (Severity: 4), (Category: IP), (Description: The socket library expect close to be called only once by os.), (Recommended Action: When this message is seen, the information in required_info have to be collected and the engineering team to be notified. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PM-3-UPDATE_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: CRS Platform Manager encountered a error while update and is not able to recover from the error. A text reason and error number will be supplied to describe the error.), (Recommended Action: No action is required as the software should be able to recover from this error. If not please contact TAC with required information) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_CLIENT-4-EXIT_ON_ERR ### Response: (Severity: 4), (Category: L2), (Description: An error occurred in the NPU client library after which the client code cannot continue. This error is encountered when a client module (e.g. cli command) has difficulty retrieving information from the NPU driver. The root cause may be located in either hardware or software.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-FANTRAY_COMM_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: System SW has lost communication with fan tray. Fan tray LED may not be consistent, (admin)# show env fan may no longer be consistent. Fans do continue to run, just no longer under system SW control.), (Recommended Action: Verify the failure, give CLI: (admin)# show env (admin)# show canb server-stats loc all every 5 minutes --> rxPkts and txPkts counters should be increasing If the failure does not alleviate after 30 minutes, give CLI: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-6-PARTNER_IS_DOWN ### Response: (Severity: 6), (Category: PLATFORM), (Description: Sysldr has detected that a node is down and has informed reddrv.), (Recommended Action: There is no action required. The system should recover by undergoing a switchover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-3-CHKPT_INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: A software error occurred when ANCP process tried to restore initialization data.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and if ANCP process is able to initialize and come up successfully after restart, then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-SHIP_PERF_UNBIND_FAIL ### Response: (Severity: 7), (Category: SYSDB), (Description: Registering performance counter with stats infra failed.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBMA-4-SVC_WARNING ### Response: (Severity: 4), (Category: OS), (Description: A service API warning is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSUB_EA-3-INIT ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: An error occurred during the initialization of IPSUB EA process. The process will restart which should recover the situation.), (Recommended Action: System will retry to start the process. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APPMGR-3-APP_ACTIVATE_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: A user requested activate operation has errored and failed.), (Recommended Action: Inspect the error information and reactivate the application after addressing any issues. The error information can be displayed through the following command: show appmgr application name info detail.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-2-UNHANDLED_EVENT ### Response: (Severity: 2), (Category: HA), (Description: This type of event is not handled.), (Recommended Action: Make sure that the event chosen is the right one.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_EVM_SEND ### Response: (Severity: 4), (Category: L2), (Description: PPP MA failed to send the specified message. The cause may be a resource starvation problem but is most likely to be an internal programming error. The error message should give more details.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart the affected PPP MA process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is route summarization in OSPF and why is it used? ### Response: Route summarization is the consolidation of multiple routes into a single advertisement. This is done by advertising a contiguous address range that covers the individual networks. Route summarization reduces the size of the routing tables and link-state databases, which improves network scalability. In OSPF, route summarization is performed by Area Border Routers (ABRs) when they advertise routes from one area into another. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-4-PKGMGR_HISTORY_UNAVAILABLE ### Response: (Severity: 4), (Category: INFRA), (Description: While preparing for an install packaging operation, the install infrastructure was unable to determine the historical set of package manager operations. This will have no impact on this packaging operation itself - however, any later attempt to abort the packaging operation may fail on this node.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FM-4-ALARM_WARNING ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Autogenerated alarm), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_OPTICS_INT_PWR_SUPPLY_ALARM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_3_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias less than or equal to the low laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BULKSTAT-3-NO_MEMORY ### Response: (Severity: 3), (Category: SNMP), (Description: Data Collection or Transfer could not be successfully carried out because of lack of memory.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-KERN_OBFL_MSG2 ### Response: (Severity: 4), (Category: MEDIASVR), (Description: This ios_msg is raised when an OBFL flash is not accessable.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-3-QLIMIT_RANGE_MAX ### Response: (Severity: 3), (Category: QOS), (Description: Configured queue-limit threshold exceeds the allowed maximum threshold), (Recommended Action: Please adjust the queue-limit) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-CLIENT_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: A FIB client behaved erroneously or there was an unexpected state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-THREAD_LIMIT ### Response: (Severity: 3), (Category: MGBL), (Description: An unexpected error caused failure to increase the maximum limit of management connections to the device. This error would affect the user only if he tries to have the number of management connections above an approximate count of 25.), (Recommended Action: Restart parser_server process (process restart parser_server). If the message recurs, copy and save the message and call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-INVALID_SID_TLV_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: A software error occured while processing updates to RIB. The error is unexpected and fatal.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_EVQ_ENQUEUE ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This is an unexpected error. The PPPoE MA process will attempt to recover by restarting. The cause may be a resource starvation problem. The error message should provide more details.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_EDM-6-SYSDB_BAG_REG_FAIL ### Response: (Severity: 6), (Category: ROUTING), (Description: The process failed while attempting to register its external data manager data blocks with SysDB.), (Recommended Action: Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-BADFUNCTIONS ### Response: (Severity: 3), (Category: MEDIA), (Description: Some required functions have not been defined in DLL. Will exit), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-4-INCORRECT_LOADPATH ### Response: (Severity: 4), (Category: INSTALL), (Description: Status information after two or more nodes were brought in parallel during the initial boot of the system.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCM_SWITCH-4-GBP_FULL ### Response: (Severity: 4), (Category: PLATFORM), (Description: The switch encountered a memory full condition. Normally this error is not expected. As per the spec, this situation should fix itself. The ports will drop packets in ingress if the situation persists.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUF-4-MCAST_MSG ### Response: (Severity: 4), (Category: OS), (Description: An incoming multicast message was received, supposedly containing data that should be persisted to non-volatile storage on the receiving location, but this persisting operation could not complete because of a problem.), (Recommended Action: This is unlikely to be immediately threatening to the router's health, but could cause misbehavior if the router is reloaded. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR implement access control? ### Response: Cisco IOS XR implements access control through the use of Access Control Lists (ACLs), allowing for the filtering of traffic based on IP addresses, protocols, and ports to enhance network security. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN_EA-6-INTF_SCALE_ERROR ### Response: (Severity: 6), (Category: PLATFORM), (Description: The number of Source interfaces configured in the system are exceeding the MAX number supported by the Platform. Only the supported number of source interfaces would be programmed in the LC for mirroring.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XBAR-7-ERR_LWM_REPLY ### Response: (Severity: 7), (Category: PLATFORM), (Description: Crossbar driver LWM reply error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-IN_MEM_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected an input memory error on link 2), (Recommended Action: This alarm is transient and should auto-clear when error condition is resolved. If the alarm doesn't clear, then please reload the card using command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-CRC_ERR_0_NPU_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: CRC error from NPU-0 on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCMD-3-MEM_ALERT ### Response: (Severity: 3), (Category: ROUTING), (Description: Memory issue found in RCMD process.), (Recommended Action: Report to Technical Support. This is an indication of a possible memory issue found in the RCMD server process. It is not service affecting and this message gets reported only when RCMD is being shut down. Please take technical support assistance to verify that RCMD process has been removed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-SYSDB_GET ### Response: (Severity: 7), (Category: INSTALL), (Description: The Install infrastructure was unable to obtain some information which it requires to complete the current request or operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE7_CODE_ERR_HIGH_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE7_CODE_ERR_HIGH interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the placed process in IOS XR? ### Response: The placed process is responsible for managing the process placement feature in IOS XR. It determines which processes should run on the RP and which ones should be offloaded to the DRP. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-CONFIG_FALLOVER ### Response: (Severity: 3), (Category: ROUTING), (Description: A speaker failed to process a configuration change for 'fast-external-fallover'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-OOR_ROUTES_THRESHOLD_WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-FIT_POWER_ON_RESET ### Response: (Severity: 6), (Category: FABRIC), (Description: This indicates that the FIT tool has forced/induced a power on reset.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-SERVICE_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: Service-Layer service initialization failed. This mostly would be a non-recoverable internal error that requires cisco support.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_EA-4-ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occured during the initialization of the process. The process will restart which should recover the situation.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-5-CLOCK_INTERFACE_1_SENDING_AIS ### Response: (Severity: 5), (Category: PLATFORM), (Description: When no external clock source is available, this status propagates to BITS output ports in T1 and E1 modes. When an external source is qualified, this alarm will be cleared.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-ROOT_USERDB_INIT_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: Locald failed to create/remove the root user database on the disk0. This will affect authentication to ksh since it refers to this database.), (Recommended Action: As a workaround an admin could create this directory in disk0 himself. This should get around the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6-6-EDM_DECODE_FAILED ### Response: (Severity: 6), (Category: IP), (Description: IPV6 could not decode data supplied by the indicated external data manager.), (Recommended Action: Restart sysdb process and try the CLI again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-INTERNAL ### Response: (Severity: 7), (Category: INSTALL), (Description: The Install infrastructure has encountered an unexpected state, and will not be able to continue operating successfully.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls mtu' command in IOS XR? ### Response: The 'mpls mtu' command is used to set the maximum transmission unit (MTU) for MPLS labeled packets on an interface. This is useful when the MPLS MTU needs to be different from the interface IP MTU, for example, when using MPLS over GRE or MPLS over Ethernet. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-CREATE_SYMLINK ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the Package infrastructure is behaving incorrectly. A symlink file involved in the current request or operation could not be created. This may impact install infrastructure functioning.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-7-DEBUG ### Response: (Severity: 7), (Category: MGMT), (Description: General debugging information for development and general diagnosis.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_CLI-7-BAD_BUFFER ### Response: (Severity: 7), (Category: HA), (Description: A NULL pointer was encountered unexpectedly.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-2-INDUCED_ENS_NOTIF ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message indicates that shelfmgr was induced to send out an ens notification for the given node by the user.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-4-INIT_FAILED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: An error was encountered while the specified process was initializing. The error message contains details about the source of the error.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-ERR_CREATE_SGSERVER ### Response: (Severity: 3), (Category: SECURITY), (Description: A configuration error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-FATAL_SWITCH_HARDWARE_INIT ### Response: (Severity: 3), (Category: INFRA), (Description: Switch hardware initialization did not complete. Switch indicates it's non operational.), (Recommended Action: Verify that all firmware and fpga images on switch and board are up to date.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-GET_APINAME_REPORT ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the infrastructure is behaving incorrectly. The Package infrastructure could not get a required API name information, so processing of the current operation will halt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-3-WARNING_STR ### Response: (Severity: 3), (Category: L2), (Description: A runtime error occurred in ASR9K IPv4 FIB module. The reason for the failure is also displayed. Please call Cisco Support with the error information.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv4] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-PCI_RAM_CORRECTABLE_ERROR_OTHER ### Response: (Severity: 3), (Category: PLATFORM), (Description: Indicates a correctable single-bit error occurred on this internal SRAM. The error is corrected transparently. The location will be written automatically before being read again. %s - name of ram that sbe occurred %x - key of error node recorded %s - error data), (Recommended Action: Ignore this unless it comes with other error message) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP weight attribute and what is its range? ### Response: The weight attribute is Cisco proprietary and is local to the router. It has the highest preference in the BGP best path selection process. The range is 0-65535 and paths with a higher weight are preferred. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_17 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_HFR_LIB-7-ERR_GET_BOARD_TYPE ### Response: (Severity: 7), (Category: PLATFORM), (Description: The platform library service call to find the hardware module type has failed. The calling application handles it appropriately.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-3-ERR_CREATE_EVENTMGR ### Response: (Severity: 3), (Category: IP), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-3-CARD_PRESENCE_DRIVER_INIT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The shelfmgr could not initialize its interface to the slot presence detection driver, due to the reason mentioned in the message. The shelfmgr will attempt to recover by restarting up to 5 times. If the issue persists, the RSP will be reset which will cause the standby RSP to take over as active.), (Recommended Action: None, since the system will perform recovery action automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-4-ERR_THREAD_COND_WAIT ### Response: (Severity: 4), (Category: FABRIC), (Description: FSDB encountered an error while attempting to wait conditionally on a thread. The operation related to the resource will be affected and the process will continue to run normally.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_MGR-4-RESTART ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: After a restart, the adjacency manager attempts to re-sync its state with AIB. A failure occurred during this process. This could result in adjacencies being erroneously deleted in AIB, and hence forwarding could be interrupted.), (Recommended Action: Wait five minutes, then restart the adjacency manager again by entering the command: 'process restart svii_adj_mgr location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFEA_MPLS_EA-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: AFEA MPLS-EA, Debug information), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-ENCAP_ERROR ### Response: (Severity: 3), (Category: L2), (Description: CFM was unable to process a change in interface encapsulation. As a result packets sent by CFM may be sent with the incorrect encapsulation. This indicates that either system resources are low, or that there is an internal problem with CFM.), (Recommended Action: Wait until any situation which is putting stress on system resources is resolved, and then try to delete and re-apply the encapsulation configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM-3-UNNUM_CFLCT ### Response: (Severity: 3), (Category: IP), (Description: The IP unnumbered specified in the message references another unnumbered interface. This is not consistent configuration.), (Recommended Action: Reconfigure one of the IP unnumbered interfaces so that the unnumbered interface does not reference another unnumbered interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-6-SERVER_DOWN ### Response: (Severity: 6), (Category: SECURITY), (Description: TACACS+ server is unreachable or down.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-VSP_UIDB_ALLOC_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: VSP Supported Scale exceeded.), (Recommended Action: Decrease VLAN ranges for VSP interfaces or delete some vsp interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_NEXTHOP ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process failed unexpectedly to update RIB after a next-hop resolution event.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-MSG_SEND ### Response: (Severity: 7), (Category: HA), (Description: An internal error was detected when trying to send a message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVM-1-CORRUPT_MLIST ### Response: (Severity: 1), (Category: OS), (Description: An Event Manager list of attached messages was found to be corrupt.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. This is an internal error and should be reported to TAC. A memory dump should be taken (to assist TAC) and the application should be restarted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP_IPC-3-SEMFAIL ### Response: (Severity: 3), (Category: SNMP), (Description: SNMP library incurred an internal software error. This error indicates sysnchronization lock crate failed), (Recommended Action: Restart process which causes failure senario. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-NOBUFFER ### Response: (Severity: 3), (Category: ROUTING), (Description: EIGRP could not allocate a packet buffer to transmit a packet. This may or may not be transient. If the packet for which the buffer was not available is HELLO then the EIGRP adjacency may flap if this issue happens long enough for the peer to detect a hold time expiry. If the packet for which the buffer was not available is a non-HELLO then the EIGRP adjacency may flap if this issue is seen long enough to exhaust the maximum number of retransmissions.), (Recommended Action: The number of packet buffers available for transmitting EIGRP packets is low. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LMRIB_API-3-MISC_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Error occurred in lmrib client lib. This could be a memory error, thread lock fail or a problem that the LMRIB client is unable to register with LMRIB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show lmrib client trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show lmrib client trace output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-MIB_CHKPT_BATCH_ERROR ### Response: (Severity: 4), (Category: L2), (Description: CFM encountered an error while trying to maintain its checkpoint database. The checkpoint database is used to manage persistent MIB index values for accessing Domains and Services over SNMP. If an error was encountered then CFM has been unable to guarantee that MIB index values will be correctly maintained across process restarts, and existing database objects may have their MIB indices re-assigned.), (Recommended Action: CFM should continue to operate normally, except for possible re-ordering of MIB index values for any configured Domains and Services. CFM will have tried to correct any errors it encountered in the checkpoint database. If additional problems with CFM configuration are observed, then restarting the CFM Global Manager may help to resolve the problem. The CFM Global Manager can be restarted by issuing 'process restart cgm' on the affected node. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-1-FATAL_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: This is an severe error message in the DPA module to indicate that an error was seen during init operation.), (Recommended Action: Please collect the console log, DPA traces (show dpa trace loc <>), Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-CT2_DEV_VERSION_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver version is not compatible with the hardware version.), (Recommended Action: Upgrade the Port controller FPGA image using the FPD procedure followed by reloading the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_LOCAL-6-PATH_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message. No user action is required.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-4-LOST_EVENT ### Response: (Severity: 4), (Category: MGBL), (Description: The CCV process failed to receive an event that was sent to it.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart ccv' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-MAXPFXEXCEED ### Response: (Severity: 4), (Category: ROUTING), (Description: Number of prefixes received from a neighbor for a given address family has exceeded the limit configured with the 'max-prefix' command.), (Recommended Action: Check the prefixes received from the neighbor and verify whether the limit should be increased, or the neighbor is sending more prefixes than expected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_GET_NODE_STATE ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed on a call to system manager to get the node related state information. It's an internal software fatal error. IS-IS process will abort.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-NO_LOG_STORED ### Response: (Severity: 4), (Category: INSTALL), (Description: The install operation normally stores the result of the install operation for the 'show install log detail' command to use. However, this was not possible for the reason given.), (Recommended Action: Use the syslogs for success/failure of the operation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_UNSUPPORTED_PROTOCOL ### Response: (Severity: 4), (Category: L2), (Description: PPP MA received a packet with a protocol id, and was not recognised by the receiving control protocol. This error message indicates that a subsystem is incorrectly delivering packets to an inappropriate PPP control protocol, the packets are dropped.), (Recommended Action: In many cases, the message will indicate that an unsupported protocol is not being handled correctly and PPP is not protocol rejecting the given protocol. Generally this won't cause problems if the mishandled and dropped packet is for a protocol that isn't running anyway. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_CLEAR_PREFIX ### Response: (Severity: 3), (Category: ROUTING), (Description: There was an error re-installing a route in the RIB after receiving a 'clear prefix' event.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAK-3-OWNERSHIP_PROCESS_FREE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The identified client attempted to access a freed packet.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-ATTR_ROMMON_LOW_MEM ### Response: (Severity: 3), (Category: MEDIA), (Description: Could not get enough memory while trying to initialize nvram.), (Recommended Action: 'Router running low in memory. Reboot if possible.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-IPT_DEBUG ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates that an error has occurred during the initialization of the debug events for IP tunnel. Specific event type is included in the message. This error prevents IP Tunnel from printing debug messages if the corresponding debug flags are turned on.), (Recommended Action: This failure occurs during process initialization. Please try restarting the process that printing this message with the command process restart location If the problem persists, please contact Cisco TAC and provide this message text as well as the information specified in required_info section.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_BAD_PAK_LENGTH ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS has received a packet which is larger than its internal buffers can handle. The packet has been ignored.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.. Consider reducing the relevant interface's MTU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHDLC_SOCK-4-ERR_PAKMAN_CORRUPTION ### Response: (Severity: 4), (Category: L2), (Description: A packet manager corruption has been reported and the cHDLC Socket process has failed to cleanup to recover from the problem. The process will exit and be automatically restarted to recover from this situation.), (Recommended Action: It is expected that restarting the process will fix this problem. This is done automatically so no action should be required. If the problem recurs, then there is a problem in packet manager. A drastic solution would be to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-3-INITFAIL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The packet subsystem was not able to initialize properly. It will be restarted by sysmgr and should recover.), (Recommended Action: If packet manager is unable to start up after several restarts by sysmgr, please collect the 'sh log' output and contact your customer support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTH_SRV-6-INFO ### Response: (Severity: 6), (Category: SECURITY), (Description: Auth Service general info message with one prameter.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_SSL-3-CERT_VERIFY_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: SSL Generic error message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-7-BADREFCOUNT ### Response: (Severity: 7), (Category: OS), (Description: --), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KENSHO_GL-6-PERFMON_STATUS ### Response: (Severity: 6), (Category: PLATFORM), (Description: The user is attempting enable/disable the performance monitoring feature on Linecard. But the feature is already enabled/disabled on Linecard.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-MTD_MKVOL_FAILED ### Response: (Severity: 3), (Category: DRIVER), (Description: The host is reporting a failure while trying to create volume on the MTD device. The MTD device volume is created once when it first boot IOS XR, but it can also get re-created while trying to recover from failure to access the device.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMIB_IFSPECIFIC_CLIENT-3-ERR_INV_MSG ### Response: (Severity: 3), (Category: SNMP), (Description: The message received requesting an operation is malformed.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What does the term 'PIE' stand for in the context of IOS XR packages? ### Response: PIE stands for 'Package Installation Envelope'. It refers to a modular combination of IOS XR software components that identifies a set of features a user wants to run on the router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FM-3-EVENT_CONN_OPEN_ALL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An internal error was detected when trying to open all event connections attached to an Event Manager.), (Recommended Action: Restarting lpts_fm may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_EXCESS_DATA ### Response: (Severity: 3), (Category: SECURITY), (Description: Received more bytes than required), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GIRO-4-CFG_RESTORE_SINGLE_INTF ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Configuration could not be restored on this interface after the interface was created.), (Recommended Action: Re-enter desired config manually. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-4-MIXEDMODE_UNSUPPORTED ### Response: (Severity: 4), (Category: PLATFORM), (Description: MIXED MODE is not supported.), (Recommended Action: Mixed mode is not supported in this card, by default all the ports will be in same mode) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PM-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The Service Platform Manager encountered an provisioning info.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect 'show log location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_SSL-6-INFO ### Response: (Severity: 6), (Category: SECURITY), (Description: SSL general info message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-CHKPT_PULSE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error in the Routine to pulse the Chkpt Thread.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMIAP-4-SYSMGR_FAILURE ### Response: (Severity: 4), (Category: IP), (Description: SMIAP failed to signal sysmgr about its process state.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EDPL_PD-4-MAX_EDPL_SESS_SUPPORTED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-SPA_SERVER_MSG_HNDLR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process cctl_spa_server location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FM-3-EDM_REGISTER_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The FM process failed to initialize its edm manager.), (Recommended Action: Check if sysdb process is blocked using 'show processes blocked'. Restarting lpts_fm and sysdb may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-4-TOP_SHMEM_USER_WARNING ### Response: (Severity: 4), (Category: HA), (Description: This process is one of the top sharedmemory users in the system. If the system reaches critical memory exhaustion, this process is subject to restart or termination. If the process is listed as 'Killed', then the system is in the process of recovering the resources used by the process.), (Recommended Action: Collect system log information. Contact technical support if the problem is not a misconfiguration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REBOOT_LIB-3-FAILED_TO_DISCONNECT_FROM_SDRNM ### Response: (Severity: 3), (Category: INFRA), (Description: Failed to disconnect from SDR NM .), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_6_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_6 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLX_FPD-3-VERSION_READ_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: PLX FPD version could not be read due to I2C errors. The output of 'show hw-module fpd' will show the affected FPD. This FPD will not be enabled to avoid potential upgrade and further issues.), (Recommended Action: In certain cases process restart of plx_fpd on affected or all locations will help to resolve the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CALVADOS_DUMPER-6-HOST_COPY_SUCCESS ### Response: (Severity: 6), (Category: INFRA), (Description: Dumper has copied core file successfully), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-TX_CH_HI_BIAS_CURRENT ### Response: (Severity: 3), (Category: FABRIC), (Description: The Tx POD detects a high bias current on a channel. The channel might not be functioning properly, and can cause cell drops, or corruption in the downstream.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-HOST_FATAL_EVENT ### Response: (Severity: 3), (Category: DRIVER), (Description: HOST has reported a fatal event.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMC-7-DEPRECATED_PATH ### Response: (Severity: 7), (Category: SYSDB), (Description: An operation has been attempted on a part of the SysDB namespace that should no longer be used.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-6-VERSION_NOTCURRENT ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: This satellite is running a software version which is compatible, but not current.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-3-UNEXPECTED ### Response: (Severity: 3), (Category: OS), (Description: A function call returned an unexpected error. Possible resource shortage or coding error.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4MC_STATIC-7-ERR_TIMER_INIT ### Response: (Severity: 7), (Category: ROUTING), (Description: Internal error. Cannot create manageed timer), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FMGR-3-DENY_IN_ACL_NOT_SUPPORTED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Deny' action for an ACE is not supported and will be ignored. The behavior will be the same as with Permit action.), (Recommended Action: If the behavior is not acceptable, remove the Qos policy from the interface, otherwise no further action is needed. 'no service-policy input|output') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-SPI_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: SPI Failure/Success while accessing device), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-PAK_WRITE ### Response: (Severity: 3), (Category: ROUTING), (Description: Error in constructing a packet to be transmitted by EIGRP. This may or may not be transient. If the packet which was not constructed is HELLO then the EIGRP adjacency may flap if this issue happens long enough for the peer to detect a hold time expiry. If the packet which was not constructed is a non-HELLO then the EIGRP adjacency may flap if this issue is seen long enough to exhaust the maximum number of retransmissions.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-MEM_CHUNK_ALLOC_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error in allocating memory. This can occur due to (1) low available memory, (2) invalid arguments), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-VE_FAN_CTLR_SENSOR_DEBUG ### Response: (Severity: 7), (Category: PLATFORM), (Description: This is for debug purpose.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_TOPAZ-7-ERR_FSM_STATE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an unexpected/invalid state while trying to process an event for a client request. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_QFPCPUCTRL-1-ERP_PAR_ERROR_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: CPU controller FPGA detected a parity error on the SPAQFPBridgeCtrl1 ERP bus during data reception from SPAQFPBridgeCtrl1.), (Recommended Action: Reboot the board. If the problem persists, replace the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISAKMP-2-PARSE_MEMORY_ERROR ### Response: (Severity: 2), (Category: OS), (Description: No memory left to parse show output data), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-SI5346_PLL_LOS ### Response: (Severity: 3), (Category: PLATFORM), (Description: SI5346 PLL loss of Signal detected/cleared for RSP), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPT-3-FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: CPT error message. %s- cpt message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR_SHARED-2-ERR_SHMEM_INIT ### Response: (Severity: 2), (Category: FABRIC), (Description: Fabric driver encountered the annunciated error during the shared memory initialization. The fabric driver cannot complete the initialization of the fabric ASICs.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGPTE_LIB-4-SERVER_ERR_CLINFO_HOLD ### Response: (Severity: 4), (Category: ROUTING), (Description: IGP failed to save its client's message channel information. This could be a result of channel down or resource allocation failure.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-ETH_SERVER_OPEN_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_HEAP-7-BAD_NCTDELETE ### Response: (Severity: 7), (Category: HA), (Description: Bad NCT record is being freed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-3-SIGNAL ### Response: (Severity: 3), (Category: FABRIC), (Description: A signal was received when the driver is not yet ready. For SIGBUS card will reload. For others the signal will be raised to the OS), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-FIA2NPU_1_PKT_MAXLEN_ERR_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet maximum length error on FIA to NPU-1 interface on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_PERSIST_SPECIAL_HANDLE ### Response: (Severity: 1), (Category: PLATFORM), (Description: An ASIC error has occured and been handled.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSLA-4-ERR_MPLSLM ### Response: (Severity: 4), (Category: MGBL), (Description: IPSLA MPLS LSP Monitor module has failed to perform an operation.), (Recommended Action: See the message text for details of failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-DIMM_FAILED ### Response: (Severity: 3), (Category: HA), (Description: Notification printed on detecting failed DIMM .), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: FABRIC), (Description: Failed to allocate memory from Heap. This can happen during periods of intense memory resource usage or due to a memory leak - though these are extremely rare occurances. This message implies some message(s) between FSDB and SFE driver was not processed and so they might be out of sync.), (Recommended Action: Capture information as specified in the required_info section. Restart sfe_drvr to clear any out of sync issues.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_14_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_PAK_CLIENT_CONN ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS encountered an error while trying to set up a managed connection to the Packet Server. This is a serious error as IS-IS requires Packet I/O services to be able to form adjacencies, and the IS-IS process will shut itself down in response. This may be due to a low memory condition but is more likely to be a software programming error. The error string and error code provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_DLL_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: Ingressq driver tried to register for a dll but it encountered an error. The driver might lose some of its functionality.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2CCTRL-2-TRANSACTION_INTERRUPTED ### Response: (Severity: 2), (Category: PLATFORM), (Description: An SMBus Transaction Interrupted by Another Master), (Recommended Action: Please attempt to correct the error by reloading the card by issuing the command in admin mode -reload location <> If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_1_EGR_Q_ERR_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Egress queue error on NPU-1 interface on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-6-REMOTE_SESSION_STARTED ### Response: (Severity: 6), (Category: L2), (Description: A remote latching loopback session has successfully started. This is for informational purposes only.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-SWITCH_EEPROM_INIT_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process timed out while waiting for the switch's EEPROM initialization to complete. In order to recover, ESD will reset the switch, then exit so that it can be restarted by the process manager and attempt to configure the switch again.), (Recommended Action: If this problem does not recur, no intervention is required to recover. To determine why this problem occurred, or if the problem occurs multiple times, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet', and 'show controllers switch trace' commands. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_13_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_13 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-7-NETIO_DEBUG_INIT ### Response: (Severity: 7), (Category: OS), (Description: An error was encountered when initializing debug.), (Recommended Action: Restarting netio may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-BIND ### Response: (Severity: 7), (Category: MGBL), (Description: XML schema browser was unable to bind to MDA. It is possible that there is a problem with MDA or the Schema Server, or the communication infrastructure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPV6-4-RIB_SEND ### Response: (Severity: 4), (Category: IP), (Description: A route insertion/deletion request failure. Most likely due to resource issue (memory, CPU utilization, etc.)), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_CLIENT-7-APPLICATION_ERROR ### Response: (Severity: 7), (Category: OS), (Description: Failed to execute some application functions.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-3-NSR_SYNC_PEER_NO_SOCK ### Response: (Severity: 3), (Category: ROUTING), (Description: Standby LDP received Init-Sync-Done notification from TCP but has no socket information from Active LDP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-3-FREE_BUFFER_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Failure to free up the rx/tx buffer after recieving a packet. %d- Error code %s- Error Description), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_UIDB-7-DEBUG_MSG ### Response: (Severity: 7), (Category: L2), (Description: This is a debug message), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_1_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Tx power less than or equal to the low Tx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Tx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Replace the QSFP+ with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FTPCLIENTMIB-3-NOTHREADCREATE ### Response: (Severity: 3), (Category: SNMP), (Description: There are no resources available to create a FTP request processing thread), (Recommended Action: 'Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_SYSDB_REG_NOTIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed to register for notification of changes on the displayed SysDB path.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The IS-IS process must be restarted before it can function correctly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-NON_LOCAL ### Response: (Severity: 7), (Category: OS), (Description: A process on another node contacted the local QSM server. The local server refused the request.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_PTHREAD ### Response: (Severity: 3), (Category: OS), (Description: The mutex lock/unlock failed), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-3-TSP_A_PKT_DECODE_DIS ### Response: (Severity: 3), (Category: PLATFORM), (Description: TSP decoder A disabled but packet received.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-INSTALL_OP_SYS_ERR_SPECIFIC_NODES_INCONSISTENT ### Response: (Severity: 2), (Category: INSTALL), (Description: Further information supplied to be used in conjunction with the SYSTEM_ERROR_SPECIFIC_NODES_INCONSISTENT_HDR message. One of the nodes possibly now in an inconsistent state with itself and the rest of the system.), (Recommended Action: Check system consistency using 'install verify'. Run 'install verify packages repair' if anomalies are found. If incorrect behavior is seen then restart processes impacted by the install on the inconsistent nodes (use 'show install log detail' for a list of impacted processes).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP-4-WARN_CLIENT_OVERWRITE ### Response: (Severity: 4), (Category: IP), (Description: ARP has overwritten an interface entry with a client entry. This can sometimes indicate a conflict with the client configuration on the interface.), (Recommended Action: Ensure that the configuration is correct for the client in question. The client has configured the same IP address as one of the interface IP addresses.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_VLAN_EA-3-VRRP_HSRP ### Response: (Severity: 3), (Category: PLATFORM), (Description: Same VRRP and HSRP ID - not supported for the same interface at a time.), (Recommended Action: Please capture the complete error log. Please check the data sheet for the supported configuration. Please contact TAC for any support on this) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-DEBUGINIT ### Response: (Severity: 3), (Category: MGBL), (Description: 'Failed to initialize a debugging event for the reason listed in' ' the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISK_DRIVER-3-FAILED_TO_ALLOCATE_TIMER_LEAF ### Response: (Severity: 3), (Category: PLATFORM), (Description: ATA device might report these errors when it unable to allocate event timer leaf.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-4-FLOWSPEC_HW_PROFILE_MISMATCH ### Response: (Severity: 4), (Category: FABRIC), (Description: 1. Mismatch found between the current flowspec profile and the newly configured flowspec profile. Needs attention with LC reload.), (Recommended Action: System LC is inconsistent. Need to reload the LC in order to activate the new flowspec profile. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-ISSU_LTRACE_INIT ### Response: (Severity: 3), (Category: INSTALL), (Description: Failed to register ltrace context structure. Tracing will not be functioning properly.), (Recommended Action: Tracing will not work properly. Process will proceed running. Can restart the process to overcome this issue. If error persists.Collect the error log with return value and core dump of the process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_3_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser temperature less than or equal to the low temperature warning threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the QSFP+ with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_COM_IFIB-7-DEBUG_INIT_EVENT ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when initializing debug. This is not a critical error, and the process can continue functioning noramlly despite this failure. Particular debug will not be effective though.), (Recommended Action: Provide the following log: Collect Console logs and output of -show logging process pifibm_server_rp loc ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-6-STBY_STANDBY_READY ### Response: (Severity: 6), (Category: HA), (Description: Redcon has determined that the standby card is ready to take over as active card if it needs to.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2VPN_FGID-3-INIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the module in the platform L2VPN component.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP-4-TIMER_FAILED ### Response: (Severity: 4), (Category: L2), (Description: An error has occurred processing one or more timer events driving the MSTP engine. The process has restarted to correct this issue.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-VRF_RECONFIGURE_HOLD ### Response: (Severity: 5), (Category: ROUTING), (Description: BGP is taking more than usual time to cleanup the VRF. This normally happens due to improper config or overflowing supported scale limitations. VRF reconfigure will not take effect until the cleanup is complete), (Recommended Action: This message is for information purpose only. Request to revisit config and scale) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_1_ERR3_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 1 ran into error-3 on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_SFRAR-3-SYSMGR ### Response: (Severity: 3), (Category: L2), (Description: The call to inform the System Manager that SFRAR is running failed. The SysMg library API failed. This was attempted to setup message handler for message syncing.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure RSVP fault management? ### Response: To configure RSVP fault management, use the 'rsvp fault-management' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#rsvp fault-management <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-CPU_IERR ### Response: (Severity: 3), (Category: DRIVER), (Description: Card manager has detected that the CPU complex in the indicated card is reporting an internal error condition that is fatal and it will be auto reset to recover from the failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-5-BIOS_NOTICE ### Response: (Severity: 5), (Category: PLATFORM), (Description: BIOS running on the indicated card is sending a notice message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-2-ASIC_INIT_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Crossbar driver detected error during ASIC Initialization.), (Recommended Action: Please try reloading the card using command 'hw-module location <> reload' to recover. If the message occurs during every power cycle then please contact tech-support. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-6-REPOPULATE_SHADOW_SUCCESS ### Response: (Severity: 6), (Category: MGBL), (Description: The shadow configuration namespace has been successfully re-synced with the actual configuration.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_SSE-3-ERR_ECM_CREATE ### Response: (Severity: 3), (Category: L2), (Description: BFD Agent encountered an error while attempting to create an event connection manager for the specified path. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective MSC reboot.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-PTHREAD_CREATE_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-3-BAUD_RATE ### Response: (Severity: 3), (Category: MGBL), (Description: The console baud rate is retrieved from the configurate register. Problems were encounted during this operation.), (Recommended Action: Check the default value that the system has resorted to and configure the terminal server to this speed. This will allow the console to be used to gain further diagnostics. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_TDM-7-OBJ_COUNT ### Response: (Severity: 7), (Category: HA), (Description: A table's object count is not what it's supposed to be. This is an internal accounting error and does not cause any problems inside checkpointing, but it may cause applications which depend on this accounting info to mis-behave.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAIPC_NETIO-7-DEBUG_INIT_FAILED ### Response: (Severity: 7), (Category: OS), (Description: debug_register() failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure QoS for an L2VPN? ### Response: To configure QoS for an L2VPN, use the 'policy-map' and 'service-policy' commands in global and interface configuration modes, respectively. policy-map POLICY-MAP-NAME class CLASS-NAME bandwidth percent 50 interface GigabitEthernet0/0/0 service-policy output POLICY-MAP-NAME <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-NO_FREE_SPACE_INFO ### Response: (Severity: 7), (Category: OS), (Description: Please free some space.), (Recommended Action: Q Please free some space.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_3_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser bias greater than or equal to the high laser bias alarm threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_LIB-7-LIST ### Response: (Severity: 7), (Category: INSTALL), (Description: The Install infrastructure encountered an error when accessing a list of internal structures, and so the requested operation may not be completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GATM-2-ERR_STR ### Response: (Severity: 2), (Category: L2), (Description: Error in gatm operation. The error message denotes the gatm operation being unsuccessful with a particular return code string. This string has been used to signify the reason of the failed gatm operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-3-APPL_COND_RESYNC_MISMATCH ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform Fault Manager Node detected a db inconsistency when performing a resync with an application.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-3-USB_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The front panel usb port is disabled.), (Recommended Action: Remove USB device and execute clear_usb_oc in aux port to enable USB port. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-3-ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An error has been detected.), (Recommended Action: If the process restarts and this message is not repeating, no actions are needed. If this message recurs, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-3-PROTECTION_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: Traffic protection impacts the filtering of traffic which would otherwise be destined for Linux applications. The configuration defines rules dictating which traffic is permitted or denied to reach Linux userspace. This message indicates that an error has occurred whilst applying the Traffic Protection configuration and so this filtering may not be working correctly.), (Recommended Action: If this is a transient issue then restarting xlncd will trigger it to retry applying nftables configuration. If this appears to be the result of particular traffic protection configuration, changing that configuration would trigger xlncd to attempt to program the new nftables configuration instead.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_LIB-3-MSG_SEND_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: A communication problem occurred between the MBI client and server. The MBI operation in progress will not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_RESTART ### Response: (Severity: 3), (Category: OS), (Description: bcdl_agent process being restart to recover from an error state.), (Recommended Action: Collect showtech bcdl and contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-MAG_DELETED ### Response: (Severity: 3), (Category: IP), (Description: --), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_EVM_ATTACH ### Response: (Severity: 4), (Category: L2), (Description: PPP MA failed to register a handler for the specified class of event. This is an initialization error and implies that PPP MA will not be able to operate correctly. The PPP MA process will abort and be restarted in an attempt to recover. The cause may be a resource starvation problem but is most likely to be an internal programming error. The error message should give more details.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart the PPP MA process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-6-INPUT_LENGTH ### Response: (Severity: 6), (Category: MGMT), (Description: This message comes when user input length is exceeded), (Recommended Action: 'Debug message only. No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_AIB_FINT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMS-6-TELEMETRY_SUBSCRIBE ### Response: (Severity: 6), (Category: MGBL), (Description: This message indicates the start or end of a dial-in or gNMI subscribe request from a client. For gNMI subscribe, this is only STREAM subscriptions. %s - This specifies the operation 'gRPC dial-in' or 'gNMI'. %s - This specifies the 'Start' or 'End'. %lu - This specifies the request ID. %s - This specifies the client network address of the form 'host:port' or '[host]:port'.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-6-STATE_CHANGE ### Response: (Severity: 6), (Category: PLATFORM), (Description: For displaying state of the SIM Service Engine), (Recommended Action: No info needs to be collected. This is an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-EDM_INIT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Initialization of the EDM server failed. It is not service impacting error but could impact MANS registers access via GASPP.), (Recommended Action: Restart the plim_services process (process restart plim_services location <>) If the issue persists, do a cold reboot Services PLIM MSC.If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TRM-3-MUTEX_ERROR ### Response: (Severity: 3), (Category: L2), (Description: A process crashed holding hash bucket mutex. The mutex is revived but hash buckets may be in inconsistent state..), (Recommended Action: None. The initialization will be retried automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-4-SESSION_EXPIRY_FAILED ### Response: (Severity: 4), (Category: L2), (Description: A loopback session could not be stopped after the expiry timer had fired. The loopback session is still running, and will attempt to be stopped every five seconds.), (Recommended Action: Either wait for the loopback session to stop as a result of the retries or attempt to stop it manually. If it doesn't stop, it may be rectified by restarting the edpl_ma process using the following command: - process restart edpl_ma) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SDT-7-BTREE_FIND ### Response: (Severity: 7), (Category: OS), (Description: The internal message storage space optimizer failed to lookup the string being stored. This is not a critical, since the string will still be stored, however it does possibly indicate a lower level memory corruption or other problem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: T3E3-4-WARNING ### Response: (Severity: 4), (Category: L2), (Description: A warning is generated while Updatng elapsed time from kernel clock. The message contains info about the location and cause of the failure and possibly anticipated actions/effects.), (Recommended Action: Verify continued correct operation of T3E3.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-THREAD_EXIT ### Response: (Severity: 3), (Category: SYSDB), (Description: A thread of SysDB server or medusa process has exited for some critical reason and will be restarted.), (Recommended Action: Check to make sure the process has restarted. If not, restart manually. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_DUPLICATE_L2_ADJ_SID ### Response: (Severity: 3), (Category: ROUTING), (Description: Same SR Adj-SID is configured on multiple L2 interfaces.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEXMGR-2-LINK_TRAIN_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: PCIE link training failed), (Recommended Action: Please reload the board using the following command: 'reload location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HM-4-FAILED_INIT ### Response: (Severity: 4), (Category: HA), (Description: HA Health Monitor failed to initialize due to internal software errors), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process hm location <>' to verify that the process is up and running. If it is still non-operational, try doing 'process restart hm location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-5-GR_LCL_RESTART_COMPLETE ### Response: (Severity: 5), (Category: ROUTING), (Description: After LDP local restart, LDP GR forwarding state hold timer has expired, and MPLS forwarding is now being updated and reinstated by LDP application. This message appears only if the mpls ldp log graceful-restart command is configured.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX-3-LINK_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error has occurred on the link between the bridge and its root port. The message has status and action taken.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-MSTATS_INIT ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when trying to initialize a statistic counter table.), (Recommended Action: Check the status of Metro Stats Server because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-SPAN_SESSION_DESTROY ### Response: (Severity: 4), (Category: PLATFORM), (Description: A failure has occurred while destroying span session.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-3-MINOR ### Response: (Severity: 3), (Category: DIAG), (Description: A minor error was detected if the diagnostic test fails for the specified card such as if a single device associated with the particular diagnostic test has failed.), (Recommended Action: Re-seat the card and retry the test. If the same result occurs after reseating the card and retrying the test, copy the error message exactly as it appears on the screen and gather the output of show tech-support and any other relevant information. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APM-5-POWER_SAVING_START ### Response: (Severity: 5), (Category: PLATFORM), (Description: When the Power-slicing has been initiated, it takes some time for the operation to be completed. Meanwhile no configuration must be made on the LC, otherwise it may cause inconsistency in the node. So a notice message is provided to user, not to do any exit mode operations and configurations for corresponding LC.), (Recommended Action: The message is just for information. To find the current status of the Slice power-saving, 'show apm psa status' can be used.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-REGISTER_EXTERNAL_PUBLISH_DIFF_ID ### Response: (Severity: 3), (Category: OS), (Description: try to register a data with diff id), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-HIGH_VOLTAGE_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK voltage greater than or equal to the high voltage warning threshold. The CPAK is the pluggable optics on the line cards. The voltage threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check the 'show environment voltages'. If the system voltage is normal then replace the optics with working one (if any). If the system voltage is not normal, then make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_1_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power greater than or equal to the high Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-CPSS_INIT_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: CPSS SDK switch initialization failed. This is a fatal fault.), (Recommended Action: Note the rc code. Root cause needs to be determined.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-INVALID_OBJECT ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code. Here is a list of possible reasons for this message (not all-inclusive). - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef trace location <> show cef platform trace all location <> show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure MPLS L3VPN VRF-lite for customer edge connectivity? ### Response: To configure MPLS L3VPN VRF-lite for customer edge connectivity, define the VRF without RD and RT and assign interfaces. vrf MyVRF interface GigabitEthernet0/0/0/0 vrf MyVRF ipv4 address 192.168.1.1 255.255.255.0 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_BRIDGING-7-MAC_CHUNK_DB_OUTOFSYNC_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: TCAM MAC chunk database is out of sync), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_MACSEC-2-LIC_ENFORCE_OOC ### Response: (Severity: 2), (Category: OS), (Description: The licensed feature is enabled without appropriate licenses.), (Recommended Action: The customer should either purchase more licenses or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-RPF_REDIRECT_NO_BW ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-3-GENERIC_FPD_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error was encountered), (Recommended Action: This error might be due to checkpoint initialization , LC ltrace event initialization failures. Please try to upgrade again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EM-7-FMS_LWM_SEND_EVENT ### Response: (Severity: 7), (Category: HA), (Description: The msg_send_event function reported an error trying to send an asynchronous message to the specified process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPM-3-ERROR_PTHREAD_CREATE ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-5-AUTH_FAILURE_DROP ### Response: (Severity: 5), (Category: ROUTING), (Description: The process encountered an error when authenticating an incoming PDU and dropped the PDU. This may be due to misconfiguration on the local or remote system.), (Recommended Action: Check the password configuration on the local and remote systems.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PM-7-WDSYSMON_ERROR ### Response: (Severity: 7), (Category: MGBL), (Description: A wdsysmon api call returned an error. This can happen when the state of a node is transitioning e.g. a line card is restarted or the node is not booted. The node id is given by the hexadecimal number after this message and is followed by a more specific error description of the cause of the failure.), (Recommended Action: Bring the node up to IOS-XR running stage and then rerun the PM show command. The node's info should be displayed after the next sample collection interval. If the PM collection for the node is not configured, configure it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBMA-2-IM_REG_FAIL ### Response: (Severity: 2), (Category: OS), (Description: Internal error registering with infra process.), (Recommended Action: Please restart mbxr_init process to recover and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBC_RSRCMON-7-DEBUG ### Response: (Severity: 7), (Category: SERVICES), (Description: Debug messages), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-RP_BIOS_BOOT_INFO_ERR ### Response: (Severity: 3), (Category: DRIVER), (Description: IOFPGA driver failed to access the CPU Complex FPGA registers to get the information about which BIOS SPI flash was used to boot the running BIOS. This information is used by the output of 'show hw-module fpd', due to this failure, the output of this command will not show current running FPD info for the Backup BIOS image if the Primary BIOS was corrupted.), (Recommended Action: Restart the iofpga_driver process will allow iofpga_driver to re-read this information from the CPU Complex FPGA.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-3-ERR_MALLOC ### Response: (Severity: 3), (Category: IP), (Description: The server has failed to acquire the required amount of memory), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-RIB_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: A RIB library call failed unexpectedly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-3-MPA_SW_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Unable to use MPA due to an internal software error. The error message describes the error.), (Recommended Action: Please try to recover by doing the process restart of the process that generated the error. If it doesn't resolve the issue, please try to recover the MPA using CLI 'hw-mod subslot <> reload'. Gather the output of the CLI 'show tech-support ethernet interfaces'. If the issue persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show l2vpn forwarding xconnect' command in IOS XR? ### Response: The 'show l2vpn forwarding xconnect' command is used to display the L2VPN forwarding information for xconnect instances. It shows the xconnect name, the outgoing interface or pseudowire, the next hop, and the MPLS label used for forwarding. This command is useful for verifying the point-to-point L2VPN forwarding plane. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-3-SLOT_INSERTION_THRESHOLD_B ### Response: (Severity: 3), (Category: PLATFORM), (Description: Backplane slot connector has card insertions exceed threshold B per current counter statistics.), (Recommended Action: Give CLI: (admin)# show plugin slot counts Service the backplane slot connector, contact Cisco TAC for assistance. If possible, reduce the frequency of card insertions into this backplane connector. Current insertion counters may be cleared with (admin)# clear plugin slot counts) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-6-GN2412_CHIP_DOWN_RECOVERY_FAILED ### Response: (Severity: 6), (Category: PLATFORM), (Description: GN2412 shows the register reading 0xff. Recovery action fails to recover the chip), (Recommended Action: 'show controllers epm-switch port-mapping location *') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV_AGENT-3-OPT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'neighbor' command in IOS XR VPLS configuration? ### Response: The 'neighbor' command is used under the 'l2vpn bridge group' to specify the remote PE routers that are part of the VPLS instance. It defines the pseudowires that connect the local PE to the remote PEs. Each 'neighbor' statement creates a spoke pseudowire to a remote PE. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CISCOSYSTEMMIB-3-SPAWN ### Response: (Severity: 3), (Category: SNMP), (Description: The MIB had trouble in spawning a process.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REPLICATOR-3-LARGE_HANDLE ### Response: (Severity: 3), (Category: LIBRARY), (Description: The replicator library has received an exceptionally large item handle from NRS which may cause conflicts within the replicator library.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-bandwidth collect frequency feature? ### Response: The MPLS TE auto-bandwidth collect frequency feature specifies how often auto-bandwidth measures the output rate of a tunnel before making a bandwidth adjustment. A higher frequency means auto-bandwidth reacts more quickly to traffic changes, while a lower frequency means bandwidth adjustments occur less often. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_HFR-3-SYSDB_BIND ### Response: (Severity: 3), (Category: ROUTING), (Description: The MFWD-HFR library encountered internal error during Sysdb init setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-3-SYSDB_ERR ### Response: (Severity: 3), (Category: L2), (Description: L2VPN could not register callbacks with SysDB for show command or configuration handling. The text of the message displays the registration operation attempted and decoded SysDB return code.), (Recommended Action: To recover from this state, one may try 'process restart' command. For example, - process restart l2vpn_mgr OR Collect 'show tech sysdb' and 'show tech l2vpn', and contact Cisco TAC support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-4-CARD_REIMAGE_CFG_DONE ### Response: (Severity: 4), (Category: PLATFORM), (Description: Setting of the reimage attribute on the indicated card has completed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to troubleshoot MPLS L3VPN BGP peering issues? ### Response: To troubleshoot MPLS L3VPN BGP peering issues, verify neighbor configurations and use 'show bgp vpnv4 unicast neighbors' command. show bgp vpnv4 unicast neighbors <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET-4-BER_ALARM ### Response: (Severity: 4), (Category: L2), (Description: The specified Bit Error Rate Alarm has been declared or released. interface: interface on which alarm is set/cleared alarm: alarm being asserted e.g: SF-BER or SD-BER status: set/cleared), (Recommended Action: If SF/SD-BER alarm is seen: Link quality degraded beyond configured threshold. Check if the peer device is injecting error frames or otherwise check if the cable is faulty.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What synchronization mechanisms are provided by the IOS XR microkernel? ### Response: The IOS XR microkernel provides the following synchronization mechanisms\n- Mutex (mutual exclusion) locks: Ensures exclusive access to shared data by threads\n- Condition variables: Allows threads to wait until a condition is met\n- Semaphores: Allows threads to wait for a shared counter to become positive\n- Atomic operations: Allows simple operations on shared data without locks\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHDLC_SOCK-4-ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialisation of the cHDLC socket process. The process will restart which should recover the situation.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-OLD_IDPROM_FORMAT ### Response: (Severity: 3), (Category: DRIVER), (Description: Outdated IDPROM format is being detect for the indicated card. The card will not operate correct without being upgraded to use the TLV format.), (Recommended Action: Use idprom_tool to upgrade the card to use the TLV format.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-7-ERR_LWM_REPLY ### Response: (Severity: 7), (Category: FABRIC), (Description: The FIA driver failed to send messaging reply.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-3-PORT_CLASH ### Response: (Severity: 3), (Category: OS), (Description: The Linux Packet classifier has detected that a Linux process and and XR process are both bound to the same port. This may cause packets which should be handled by Linux applications to get dropped.), (Recommended Action: One of the processes will need to use a different port. This may be an arbitrarily assigned ephemeral port value, in which case restarting the impacted XR process should get it to use a different value. Alternatively, depending on the impacted Linux process, restarting that may force it to use a different port. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-EVENT_CONN_NOTIFY_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: During initialization, CLNS failed to register for essential notifications regarding the state of the connection for the specified service. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-EBS_CPP_HP_FIFO_FULL ### Response: (Severity: 0), (Category: PLATFORM), (Description: Egress Buffer and Scheduling to CPP high priority FIFO full.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFLX_LIB_MGR-3-PTFM_BW_ERR ### Response: (Severity: 3), (Category: SERVICES), (Description: The Interflex Manager failed to get the interface bandwidth from platform at the startup. The process will be automatically restarted, if it keeps restarting with same message *DDTS*), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_QFPCPUCTRL-1-CPU_PAR_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: CPU controller FPGA detected a parity error on the CPU A/D bus during data reception from the CPU.), (Recommended Action: Reboot the board. If the problem persists, replace the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE6_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE6_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-6-INFO_NVRAM ### Response: (Severity: 6), (Category: SECURITY), (Description: Sufficient NVRAM is not available to perform a system operation. It is possible that the NVRAN process might be temporarily down.), (Recommended Action: 'This message is just for information.No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-2-MSC_140_POWER_DISABLED_STATE_NOT_RECOVERED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Card stays in power disabled state), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBIPV6PROTO-3-LAS_INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: This is a transient error and it happens when the underlying communication layer, Group Service Process (GSP), is temporarily unavailable.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install remove command in IOS XR? ### Response: The 'install remove' command is used to delete inactive packages from the router's storage. This helps to free up disk space. Only inactive packages can be removed. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DATA_SWITCH-3-LINK_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Data Path switch link has failed.), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-5-ERR_NON_EXISTS_ACL ### Response: (Severity: 5), (Category: OS), (Description: acl string is non-effective. Acl string provided is not mapped to any access-list mentioned for ipv4, so its not effective.), (Recommended Action: When this issue happens, first try to create the acl string match with ipv4 access list and then map it to the LPTS.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-6-ENFORCE_EVAL ### Response: (Severity: 6), (Category: LICENSE), (Description: The licensed feature is enabled for evaluation.), (Recommended Action: The customer may consider to register for licenses.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMC-7-PARSE_FAILED ### Response: (Severity: 7), (Category: SYSDB), (Description: A pathname was used for a SysDB operation from which the destination node could not be parsed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-JID_UPDATE ### Response: (Severity: 3), (Category: OS), (Description: Proc table empty.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support sysdb command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support sysdb output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-SM_CALLBACK_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Failed to register with Install manager for software change notifications. OBFL manager will restart.), (Recommended Action: If the issue is seen after restart, Please collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM-3-CFLCT_FORCED_DOWN ### Response: (Severity: 3), (Category: IP), (Description: The specified IP address conflicts with other IP addresses on the network portion of their IP addresses and has been forced down to prevent multiple operational conflicting IP addresses. This is an inconsistent configuration.), (Recommended Action: Reconfigure the IP addresses that share the common network portion specified.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: netio_debug-3-INIT_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The NetIO debugging partner process initialization failed. This could happen due to errors in various server processes. The error code and its text in the message will reveal the source of the error.), (Recommended Action: NetIO debugging partner process is only needed to capture/log packet info and for debugging purpose only and does not effect system functionality. If the process restarts and this message is not repeating, no actions are needed. If this message recurs that does mean there is an underlying infra components issue, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-HA_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: HA test error.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_LWM ### Response: (Severity: 3), (Category: OS), (Description: A call to a LWM interface failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'maximum-prefix' command in IOS XR BGP configuration? ### Response: The 'maximum-prefix' command allows limiting the total number of prefixes that can be received from a BGP neighbor. If the limit is exceeded, the BGP session can be either torn down or a warning message can be logged, depending on the configuration. This provides protection against a BGP neighbor that advertises an excessive number of prefixes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls ldp neighbor targeted' command in IOS XR? ### Response: The 'mpls ldp neighbor targeted' command is used to establish a targeted LDP session with a specific neighbor. Unlike link-based LDP sessions, targeted LDP sessions are not tied to a specific interface. They are used in scenarios where the LDP peers are not directly connected, such as in L2VPN and VPLS configurations. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-6-FMI_CONFLICTING_CONFIG ### Response: (Severity: 6), (Category: SECURITY), (Description: Two Firewall Management interfaces of the same type (follow-active or follow-standby) have been configured on the specified firewall. Both of the interfaces will be brought down until the conflicting configuration is removed.), (Recommended Action: Remove the conflicting configuration from one of the Firewall Management interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-ROOT_USERDB_INIT_PATH_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: Locald failed to create/remove the root user database on the disk0. This will affect authentication to ksh since it refers to this database.), (Recommended Action: As a workaround an admin could create this directory in disk0 himself. This should get around the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_14_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTNLC_FPD-3-CPMI_INIT_FAILED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-MQ_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_OUT_MEM_CORR_ECC_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast output memory correctable ECC error on link 2), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-6-ENFORCE_GRACE ### Response: (Severity: 6), (Category: LICENSE), (Description: The licensed feature is enabled in grace period.), (Recommended Action: The customer may consider to purchase licenses.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-3-FAILURE ### Response: (Severity: 3), (Category: L2), (Description: SPA Jacket error), (Recommended Action: When errors occur in jacket, it is very likely the jacket process will restart itself. please collect output of debug sip-pm <> ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-4-TAP_UPDATE_SUSPENDED ### Response: (Severity: 4), (Category: FABRIC), (Description: TAP read consumed too much time.), (Recommended Action: collect the logs mentioned above) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-FSDB_SERVICE_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: The FSDB was not able to connect with the above error condition.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_EVM_ATT_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to register a handler for the specified class of event. This is an initialization error and implies that IS-IS will not be able to operate correctly. The IS-IS process must be restarted in order to recover. The cause may be a resource starvation problem but is most likely to be an internal programming error. The error message should give more details.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart the IS-IS process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP_AD-3-OUT_OF_LABEL ### Response: (Severity: 3), (Category: L2), (Description: 'This error happens when the system had failed to allocate a label block ' 'as it may be running out of the label blocks. ' 'Note that when label blocks are freed, they go to zombie state for ' '30 minutes. During this period, repeated addition/removal of the same ' 'configuration will result in allocating different label blocks each time. ' 'This can lead to running out of label blocks quickly '), (Recommended Action: 'Please remove l2vpn config and wait for 30 minutes until the zombie ' 'pool is cleared and put back the config. ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE2_CODE_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE2_CODE_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-3-ERR_PULSE ### Response: (Severity: 3), (Category: L2), (Description: IPC thread received an async event pulse for which there is no handler under FSM Status msg handlerroutine.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_EXMEM-7-DEBUG_MSG ### Response: (Severity: 7), (Category: L2), (Description: This is a debug message), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different types of BGP path attributes? ### Response: The main BGP path attributes are\n- Weight (Cisco proprietary)\n- Local Preference\n- AS Path\n- Origin\n- Multi-Exit Discriminator (MED)\n- Community\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-2-DEV_VERSION_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: RSP CPU controller driver version is not compatable with the hardware version.), (Recommended Action: If a redundant RSP card has been configured force a failover with the following command in admin mode 'redundancy switchover'. Upgrade the RSP CPU controller CPLD image on the RSP that reported this problem, followed by reload of that RSP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-7-FDOPEN ### Response: (Severity: 7), (Category: MGBL), (Description: 'The call to function fdopen failed. The error message is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEA_DLL-3-REPRGM_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: TCAM entries are reprogrammed every 24 hours to ensure accuracy of hardware entries programmed earlier on user configuration or system changes. This message lists the ACL for which errors have occured during reprogramming.), (Recommended Action: Detach ACL in the error message from all interfaces of the line card where issue is seen. Now, re-attach ACL to the interfaces. Note that, there is a security hole during re-attachment operation window for these interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-4-SHOW_WARNING ### Response: (Severity: 4), (Category: ROUTING), (Description: The show thread could not acquire the mutex to service the show request. The main thread in te_control may be busy/blocked/hogging while holding That mutex.), (Recommended Action: Try to run the show command again. If the error reoccurs, then check the state of the te_control process (show process te_control). If thread number 1 is blocked for an extended period of time, contact your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCC-2-FAILED_ID_HW ### Response: (Severity: 2), (Category: PLATFORM), (Description: 'There was a problem while identifying Hardware in the specified location.'), (Recommended Action: 'Contact TAC') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-7-DEBUG_INSTALL_WILL_REBOOT_NODE ### Response: (Severity: 7), (Category: PLATFORM), (Description: DSC process is not reloading node since a reload install operation is ini progress. Install will reload node after install complete.Heartbeat loss messages are expected during this time.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-5-CLOCK_INTERFACE_0_SENDING_AIS ### Response: (Severity: 5), (Category: PLATFORM), (Description: When no external clock source is available, this status propagates to BITS output ports in T1 and E1 modes. When an external source is qualified, this alarm will be cleared.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-XFP_WARN_RX_PWR ### Response: (Severity: 4), (Category: L2), (Description: XFP hit/recovered RX Low power warning.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM_COMMON-6-MOVE_DONE ### Response: (Severity: 6), (Category: MEDIA), (Description: Previously due to some error, NVRAM dump file was collected. At the time of collection, permanent storage was not available so it was saved at /tmp directory. To avoid the loss of this file, this file was copied out from /tmp directory when permanent storage became available), (Recommended Action: Collect dump file from permanent storage for further inspection. Collect syslog) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAW_LIB-3-EDM_ERR ### Response: (Severity: 3), (Category: MEDIA), (Description: Capture EDM errors for reboot history.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-6-THRESHOLD_CLEARED ### Response: (Severity: 6), (Category: INFRA), (Description: The specified SLA threshold has been cleared after a breach.), (Recommended Action: None. The clearing of this threshold indicates that the performance of the network has returned to above the threshold level after a previous breach.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SGT_FIFO_OFLOW_1_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress sgt fifo overflow on xaui-1 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-GRP_GSP_NODEID_FAIL ### Response: (Severity: 3), (Category: SYSDB), (Description: This message may appear due to transient error and can be safely ignored as sysDB will retry the find operation. However, if this repeats there could be an issue with the GSP or sysdb.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN-3-INVALID_ASIC_ID ### Response: (Severity: 3), (Category: L2), (Description: The ASIC Id is not valid, this might be a program level issue), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-4-ERR_CHKPT_INSERT ### Response: (Severity: 4), (Category: FABRIC), (Description: Ingressq Checkpoint Insert error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-CLOSE_FILE ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the file system is in error, or the Package infrastructure is behaving incorrectly. A file involved in the current request or operation could not be closed. This will not affect the current operation, but subsequent operations may be affected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EM-7-EEMED_EA_ATTACH ### Response: (Severity: 7), (Category: HA), (Description: The event detector has failed to attach an event handler for asynchronous messages.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMGR-3-EVM_CREATE ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when creating Event Manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-LSP_EXPLICITROUTE ### Response: (Severity: 5), (Category: ROUTING), (Description: The specified tunnel explicit-route has changed.), (Recommended Action: None. This is a solicited message and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDLPROD-6-MSG_GENERIC_FUNC ### Response: (Severity: 6), (Category: OS), (Description: BCDL producer dll encountered an error.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-6-PA_FF_OPEN ### Response: (Severity: 6), (Category: OS), (Description: An internal error was detected when trying to connect to the Port Arbitrator as a Flow Forwarder.), (Recommended Action: Restarting lpts_pa may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-4-QFP_FAILURE_SPI4_SYNC_CHECK ### Response: (Severity: 4), (Category: L2), (Description: The SPA bridge controller detected a SPI4 error between itself and QFP), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers QFPCPUBridge trace <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers QFPCPUBridge trace <> output, call your Cisco technical support representative and provide the representative with the gathered information. before reloading the line card If this problem persists, reload the line card using hw-module location <>/<>/CPU0 reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SESVI_EA-3-INTERNAL_ERR ### Response: (Severity: 3), (Category: SERVICES), (Description: An unexpected internal error has occurred in the SESVI EA process. The process will restart.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-INITIALIZATION_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: Service-Layer library initialization failed. This mostly would be a non-recoverable internal error that requires Cisco support.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KIM-3-LOG_ERR ### Response: (Severity: 3), (Category: INFRA), (Description: please see show kim log for more information.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IEP-3-DAEMON_ERR_SYSDB_RESUME ### Response: (Severity: 3), (Category: IP), (Description: An error occurred while resuming configuration before IEP process exits.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Collect: -show tech-support sysdb for further analysis of the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_IP_EA-3-ERROR2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IP EA. Here is a list of possible reasons for this message (not all-inclusive). - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Resource limitations. This condition indicates a problem where the software has limited resources to operate on.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv4 show memory summary show cef ipv4 location <> show memory location <> show cef ipv4 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROL_DRIVER-0-BAD_ID_HW ### Response: (Severity: 0), (Category: DRIVER), (Description: Hardware in the specified location could not be identified as genuine Cisco product by card manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-AIB_INIT_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'AIB Initialization failed.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists.' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-SID_CFG_CONFLICT ### Response: (Severity: 3), (Category: ROUTING), (Description: The same prefix SID cannot be configured (either as index or absolute) value on more than one prefix on the router. The prefix SID will not be used until this config inconsistency is resolved.), (Recommended Action: Fix the configuration such that the SID value does not conflict. Ignore if this is already done and warning will repeat until this is fixed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the two types of LSPs used in IS-IS and what is their purpose? ### Response: The two types of LSPs are: 1) Non-pseudonode LSPs which are generated by each router and describe the state of the router's links to its neighbors. 2) Pseudonode LSPs which are generated by the DIS and describe all routers attached to a broadcast network. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_EXEC-3-REGISTER_ERROR ### Response: (Severity: 3), (Category: L2), (Description: registration has failed and the CLI will exit), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_1_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser temperature greater than or equal to the high temperature warning threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-CARD_CLOCK_FAULT ### Response: (Severity: 3), (Category: DRIVER), (Description: Card clock is reporting fault condition. This is a fatal failure condition that might point to HW problem. CCC driver state machine will try to recover from the failure by reloading the card.), (Recommended Action: If CCC driver power-off the card because the problem persist after all the recovery reloads have failed, then contact with Cisco support team.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-FABRIC_PRGM_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Failed programming batch in fabric from PD.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_14_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER_SNAP-6-LIMITED ### Response: (Severity: 6), (Category: OS), (Description: A non-invasive voluntary coredump was requested by the process, but was declined since this would exceed the configured rate-limit.), (Recommended Action: None, this is benign.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_INARP-3-PVC_VC_CLASS ### Response: (Severity: 3), (Category: L2), (Description: A vc-class was configured on an interface but couldn't be applied. It could be a system-level issue or some issue with InARP itself.), (Recommended Action: If the message keeps on coming for almost every interface, collect require_info and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-STATSD_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An operation failed during the Stats Server Connection opening.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAP_LISTEN-3-EVENT_MGR_CREATE_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A problem occurred while calling the event_manager_create() API. or a connection to the event_manager failed during the initialization of the SAP listener.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging processes sap_listen error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging processes sap_listen error output, call your Cisco technical support representative and provide the representative with the gathered information. Using the Job ID from the above command, please run the following command: Copy the error message exactly as it appears on the console or in the system log. Issue the show evm trace jid errors command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show evm trace jid errors output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show sap trace detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show sap trace detail output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_EA-3-MEMBER_CAPS_ADD_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The MFR EA process failed whilst trying to set caps.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-PARAMETER_REFERENCES_NULL ### Response: (Severity: 7), (Category: INSTALL), (Description: An invalid parameter has been unexpectedly passed to the Install infrastructure. This is a coding error. The current request or operation will not be completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-4-CONFIG_FAIL_RESUME ### Response: (Severity: 4), (Category: L2), (Description: An error was encountered while attempting to return the status of a config apply request. The CLI may be blocked, or may have returned an error despite the operation having succeeded.), (Recommended Action: The edpl_ma process should be restarted using the following command: - process restart edpl_ma) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR_API-6-CEMGBL_GOT_NOTIF_FROM_ETHSERVER ### Response: (Severity: 6), (Category: PLATFORM), (Description: Cemgbl got notification from ETH_SERVER and displays the count and 1st index of it.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-CPUSHARES_LIMIT ### Response: (Severity: 3), (Category: OS), (Description: The virtual service machine definition file is requesting more CPU shares than the system has available for virtual services.), (Recommended Action: Deactivate any other virtual services to free up CPU share resources and activate this virtual service. If that does not address the problem, then enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCFIND-6-EVENT_BLOCK ### Response: (Severity: 6), (Category: OS), (Description: An error occured whilst Procfind was waiting for messages, Procfind ignored the error and continued to wait for more messages.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG_PLAT-7-UNKNOWN_NODE_TYPE ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the card type is invalid, or the infrastructure is behaving incorrectly. The current request or operation may not be carried out.), (Recommended Action: Upgrade to latest OS release. Check for unsupported hardware.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-6-ROOT_DEVICE_BUS_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: A PCIe bus error has occurred on the root port. The message has the root device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDR-3-INIT_FAILED ### Response: (Severity: 3), (Category: DRIVER), (Description: CDR init failed for that specified slot/cdr'), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DAD-3-SYSMGR_PROC_CLEANUP_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: A failure occured while trying to ask sysmgr for cleanup events for package un-installs.), (Recommended Action: Check whether policy_repository process is running properly by command 'show process policy_repository' Check the install logs if all the packages are downloaded and install operations completed properly) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM_POLICY-3-ORA_INSTBUILD ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error in the routing policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does OSPF handle virtual links and when are they used? ### Response: Virtual links are used to connect an area to the backbone (area 0) if no direct physical connection exists. They are configured on ABRs. A virtual link is a logical connection that acts as an unnumbered point-to-point connection. Virtual links cannot be configured through stub areas. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-DEPRECATED_API ### Response: (Severity: 3), (Category: LICENSE), (Description: The platform code is calling a deprecated function. The code needs to be changed to call the new function), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_14_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_14 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMIO-3-INVALID_SLOT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Invalid Slot Type.), (Recommended Action: Correct slot should be used.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ETHER-3-LTRACE_INIT ### Response: (Severity: 3), (Category: L2), (Description: PLIM process encountered an error during software initialization. ltrace initialization is failed. So it will not generate any traces.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed. There was problem with hardware or software initialization. This problem can be resolved by reloading the LC 'hw-module location <> reload' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PORT_CFG-3-INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: A submodule was unable to initialze due to the specified error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSI_MASTER-2-INVALID_THREAD ### Response: (Severity: 2), (Category: OS), (Description: Detected single-threaded RSI Master code running on an unknown thread. This concurrency can result in corruption. %d/%d indicate actual tid/expected tid.), (Recommended Action: Collect RSI traces) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-DC_NOT_PRESENT ### Response: (Severity: 4), (Category: DRIVER), (Description: CCC Driver has detected that the daughter card is either disconnected or not present.), (Recommended Action: Please inspect the card and the card connectors for physical damages and ensure daughter card is connected properly. Physically OIR the card and check if the issue persists. required_info: Collect all syslogs and trace messages for CCC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_PFI-3-GET_PIC_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Platform PFI was unable to get npu id from pic. The returned error code should indicate the reason for the failure of the api. This is a transient error in the system likely due to some config events. The client logging this error should retry the api and/or handle this error accordingly. If this error is seen persistently, Initiate the recommended action.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_DPM-6-DISCOVERY_DOWN_NO_NBR_INFO ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The Satellite is missing neighbor information, so if this satellite is part of a chain, only the current satellite rather than the full chain is undiscovered. Note that if undiscovery of the chain of satellites is required, then the discovery protocol will time out for those satellites after 30 seconds and cause undiscovery.), (Recommended Action: Check the transport layer between the host and the satellite and ensure that the satellite is working as expected. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FORGE_CGN_HA_AGENT-3-HEARTBEAT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Heart beat responses are missed from CGV6 cores.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-6-CUSTOMER_DELETED ### Response: (Severity: 6), (Category: IP), (Description: The administrator deleted a peer MAG from the LMA configuration.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-INVALID_DEACT_MSG ### Response: (Severity: 3), (Category: OS), (Description: The virtual service deactivate message was received, however, the data it contained could not be interpreted.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_PAK_CLIENT_CONN ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-INITIALIZATION_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: The QSM process wasn't able to startup up due the indicated failure during initialization. A restart of the process will be attempted. If the process can not be sucessfully started after several attempts, the board will probably be unusable.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-2-PAYG_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The port is enabled without the necessary PAYG license.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-3-PATH_FAILED ### Response: (Severity: 3), (Category: OS), (Description: Dumper copies a core dump to /tmp/dumper. There are 2 reasons for this to happen: a) No space in /tmp/dumper and exception paths. b) A core is already getting copied to /tmp/dumper.), (Recommended Action: Please make sure that there is enough space in the configured exception paths and /tmp/dumper. If the issue is not resolved, please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. follow process 6. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-7-DEBUG_CLEANUP ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when cleaning up debug.), (Recommended Action: This is not a critical error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IPV6_EA-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Typically, this is an error where the software fails due to failure during forwarding feature programming. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show cef ipv6 location <> show cef ipv6 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-LEAF_DEPEND_CLEANUP_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: This is an unexpected state where after leaf deletion, leaf still has some dependent paths pointing to it. This could prevent the leaf from getting freed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_1_LOSS_OF_SYNC_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Loss of sync on NPU-1 interface on bridge instance-0.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-MISS_EOP_1_XAUI_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Missing EOP-1 from XAUI on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_DEBUG_REG ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-4-MOVE_FAILURE ### Response: (Severity: 4), (Category: MEDIA), (Description: Previously due to some error, NVRAM dump file was collected. At the time of collection, permanent storage was not available so it was saved at /tmp directory. NVRAM process tried to move this file out to permanent storage but it failed. This file maybe required to identify if there is real issue with NVRAM device. Collect dump file from /tmp directory for further inspection.), (Recommended Action: Collect dump file from /tmp for further inspection. Collect syslog) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-6-PW_RECOVERY_INVALID_TTY ### Response: (Severity: 6), (Category: MGMT), (Description: This is expected when trying to invoke password recovery on non-console), (Recommended Action: 'Debug message only. No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_RELOAD_BOARD ### Response: (Severity: 1), (Category: PLATFORM), (Description: An ASIC error has occured and need to reload board), (Recommended Action: An error has happened and board is reloaded. Collect required information and contact TAC *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_TOPAZ-4-ERR_NETIO_CONN ### Response: (Severity: 4), (Category: PLATFORM), (Description: Cannot connect to netio pak server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_HFR-7-ERR_RRW_LOCK ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server failed to aquire rrw lock to the request record area in shared memory.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ACL-3-LTRACEINIT ### Response: (Severity: 3), (Category: ACL), (Description: Initialization of the ltrace debug capability failed with the reason displayed in the error message. This failure does not impact the functionality of ipv6 access-lists. However, debugging of any issues will be impaired.), (Recommended Action: This message may occur during process initialization. Please try restarting the process that issued this error message with the command. process restart location . Process name should be printed in the message already.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_1_XAUI_RDY_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: NPU-1 XAUI not ready on bridge instance-2.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-MSG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Error encountered while handling messages received by locald.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA-4-ERR_SYSMGR ### Response: (Severity: 4), (Category: L2), (Description: The process was initialized successfully but was unable to inform System Manager of the success.), (Recommended Action: Check on the status of the sysmgr process on the node from which the error was reported. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPU_PKT_F3_FULL ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPU packet FIFO 3 full.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-4-DATAPLANE_BATCH ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The VPDN MGR failed to program the dataplane for 1 or more sessions. These sessions must be distributed from VPDN MGR to all instances of L2FIB on all nodes. This failure may affect the establishment or tear-down of 1 or more sessions. In the case of tear-down, these resources may be leaked.), (Recommended Action: Allow sessions to re-establish. For sessions that fail to tear-down, either restart the vpdn_mgr process or the l2fib_mgr process on all nodes. You may also clear L2FIB tables. This may have significant service disruption. If the problem persists, contact technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-3-GEN_ERR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error in CPU Control FPGA operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-OPEN_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Could not open a file), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-7-DEBUG_MSG ### Response: (Severity: 7), (Category: L2), (Description: This is a debug message in the optics driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_1_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MIRROR-3-ERR_SYSDB_EDM_REG ### Response: (Severity: 3), (Category: MGBL), (Description: 'Failed to register edm with sysdb'), (Recommended Action: Collect the following details: 1. Command issued 2. show mirror trace. 3. console logs. 4. If config is restored from file, then filename/contents. 5.If command failed at startup, show config trace and show config failed startup.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUMI-3-SECURE_BOOT_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: A Secure Boot validation error has been detected on the indicated card. The details are provided together with the message.), (Recommended Action: The recovery action depends on the type of failure reported.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_1_HIGH_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TTI_MISMATCH ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_14_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE interarea tunnels feature? ### Response: The MPLS TE interarea tunnels feature allows MPLS TE tunnels to be established across IGP area boundaries. This enables TE to operate in multi-area environments. Interarea TE tunnels comprise hops in different IGP areas and are signaled as a contiguous end-to-end LSP. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-IDT_DIFF_NODE_TYPE ### Response: (Severity: 7), (Category: HA), (Description: Just debug information to know that active RP is of different endian type.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls ip-ttl-propagate' command in IOS XR? ### Response: The 'mpls ip-ttl-propagate' command is used to enable the propagation of the IP TTL value to the MPLS TTL field when an IP packet is imposed with an MPLS label. This allows the TTL to be decremented at each hop in the MPLS network, providing a mechanism to prevent forwarding loops. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-3-EVM_CREATE ### Response: (Severity: 3), (Category: TOPOLOGY), (Description: Could not connect to event manager.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-3-FAB_UNICAST_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: A problem is detected by loopback test to the Crossbar chips on this RSP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-OOR_VRF_BSR_CRP_LIMIT ### Response: (Severity: 3), (Category: ROUTING), (Description: OOR Error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-1-FFI_LINK_BRINGDOWN ### Response: (Severity: 1), (Category: FABRIC), (Description: A fabric link was brought down due to too many errors.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PA_FF-3-TLVLIB_INIT ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when initializing(tlvlib)in PA Flow Forwarder I/O thread.), (Recommended Action: Restarting lpts_pa may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_CLIENT-6-GEN_INFO ### Response: (Severity: 6), (Category: FABRIC), (Description: FIA driver operation information.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM_PD-3-REPLAY_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Validation after Bundle replay failed.), (Recommended Action: Manual bundle shut is needed to avoid traffic impact.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_0_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser temperature less than or equal to the low temperature warning threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the QSFP+ with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-7-ISM_PD_LIB_CE_CONN_WARN ### Response: (Severity: 7), (Category: INSTALL), (Description: During ISSU, verifying the CE connection's having that all active RPs are connected to active SC. If there is no valid active CE connection between active RP and active SC then that particular racks goes into isolated state.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-1-ERR_PD_PROG_DEFAULT ### Response: (Severity: 1), (Category: OS), (Description: An error was returned when programming default pre-fib entry. process exit is triggered to recover.), (Recommended Action: *Check why default entry could not be programmed*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: attestation_agent-6-IMA_BLOCK_SIGN_VALIDATION_DISABLE ### Response: (Severity: 6), (Category: MGBL), (Description: A failure occurred during Runtime integrity validation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_PRM-3-DELAY_API_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The specified error happened during the intialization of the delayed statistics freeing utility.), (Recommended Action: Please collect output of the following commands: show platform show platform vm show log show process blocked location <> show process fib_mgr location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN-3-FREE_ARENA_FAILED ### Response: (Severity: 3), (Category: OS), (Description: SHMWIN failed to free the arena's virtual range back to the server. This is possibily an indication of shmwin memory corruption), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture - show logging - show shmwin trace all location 0/x/CPUx - dumpcore running location 0/x/CPUx) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-NULLCHARMISSING ### Response: (Severity: 3), (Category: MGBL), (Description: 'Parser messages must be null terminated.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_1_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias less than or equal to the low laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_MEM_ALLOC ### Response: (Severity: 4), (Category: L2), (Description: Memory allocation failed.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-REDUNDANCY_STANDBY ### Response: (Severity: 7), (Category: OS), (Description: Node is redundancy standby state, so can't log to other node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-7-HW_INIT_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the Platform LC Hardware in L2FIB component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-2-CLKCTRL_RX_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Timing and CPI controller FPGA reported that the data it received had parity error), (Recommended Action: Please correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-4-MPLS_HW_PROFILE_MISMATCH ### Response: (Severity: 4), (Category: FABRIC), (Description: 1. Mismatch found between the current mpls profile and the newly configured mpls profile. Needs attention with RSP reload.), (Recommended Action: System is inconsistent. Need to reload the RSP in order to activate the new mpls profile. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-3-SYSDB_BIND_ERR ### Response: (Severity: 3), (Category: L2), (Description: L2VPN attempted to bind with SysDB at the specified path and could not establish a connection. The text of the message displays the specific bindpoint and the decoded SysDB return code. As L2VPN was not successful in connecting using this path, configuration or show commands specific to this path will not be handled by L2VPN.), (Recommended Action: To recover from this state, one may try 'process restart' command. For example, - process restart l2vpn_mgr OR Collect 'show tech sysdb' and 'show tech l2vpn', and contact Cisco TAC support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_HWOFFLOAD-4-LC_TIMER_SCALE_LIMIT ### Response: (Severity: 4), (Category: PLATFORM), (Description: LC level scale limit for this timer has been reached.), (Recommended Action: All new sessions on this LC will be kept in ADMIN-DOWN state.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_SYSDB_REG_NOTIF ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB external data manager failed to register for notifications for the specified path. Process would continue to run normally, except that SNMP traps will not be generated for changes in fabric state.), (Recommended Action: This message indicate that trap notifications of the operational states of planes and bundles would not occur. If snmp managability is not enabled, this message can be ignored. However, if this functionality is necessary then restart the process by issuing the following command at the CLI of the active RP after collecting all the output of all the specified commands. 'admin process restart fsdb_server/fsdb_aserver loc ' Restart fsdb_server if the bundle state traps are missing else if plane state traps are missing restart fsdb_aserver. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of SNMP in network monitoring and management? ### Response: SNMP (Simple Network Management Protocol) is used to monitor and manage network devices. It allows network administrators to collect information about device status, performance, and configuration, as well as modify device settings remotely. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARBMGR-4-INIT_ERROR ### Response: (Severity: 4), (Category: OS), (Description: An unexpected init error condition encountered.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CVAC-4-CONFIG_DONE ### Response: (Severity: 4), (Category: MGBL), (Description: The CVAC (Cisco Virtual Appliance Configuration) subsystem read and applied router configuration from the specified file, which will now be removed from the system for security. More information can be found in the provided file or CLI command.), (Recommended Action: Informational message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-5-DOWNLOAD_METHOD_ERR ### Response: (Severity: 5), (Category: L2), (Description: The specified download method is not supported), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-4-NOT_MONITORING_TEST ### Response: (Severity: 4), (Category: DIAG), (Description: The specified test number cannot be used as a health monitoring test.), (Recommended Action: Nothing. The system is working properly and the specified test cannot be configured as a health monitoring test.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-7-SYSDB_TUPLE_ERROR ### Response: (Severity: 7), (Category: OS), (Description: Invalid sysdb tuple), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: Multilink_CLNT-3-MSG_SEND ### Response: (Severity: 3), (Category: L2), (Description: Could not retrieve bundle info. Received error value On sending message to the channel.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel primary feature? ### Response: The MPLS TE auto-tunnel primary feature enables the automatic creation of primary MPLS TE tunnels between tunnel head-end and tail-end routers. It simplifies the provisioning of TE tunnels by automatically creating them based on a template configuration. Auto-tunnels are created to next-hop routers learned via IGP. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-4-GROUP_MSG_LONG ### Response: (Severity: 4), (Category: ROUTING), (Description: A 'who has this' dll message was longer than its content implied. This indicates either a corruptions of the message itself or a failure of the client to build the message correctly.), (Recommended Action: Observe system for other failures contact support team.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-3-NON_COMPLIANT_PS ### Response: (Severity: 3), (Category: PLATFORM), (Description: Should a non-Cisco power supply be installed into the Cisco QQ chassis, upon detection as non-compliant, IT WILL BE SHUTDOWN. Please note that using non-Cisco power supplies MAY RESULT IN COMPLETE CHASSIS SHUTDOWN due to insufficient power), (Recommended Action: Insert Cisco power supply) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-RESET ### Response: (Severity: 3), (Category: FABRIC), (Description: Ingressq Seal ASIC error halt occur.), (Recommended Action: If it is possible to isolate the trigger point for the sn link error, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_MQ_SEQ_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue sequence error on XAUI 1 MQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PMLIB-6-WM_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The Platform Manager client library is indicating the usage level of buffer memory.), (Recommended Action: This message might be seen when scale configs are applied. If the buffer usage is reducing in some time, no action needs to be taken. If the buffer usage is continuously increasing over a period of time then it could be an indication of the buffer stuck for some reason. Check if the process is blocked using- 'show process blocked location ' Please collect output for 'show log location ' 'show memory summary location ' 'show controller pm trace error location ' from that location. 'show controller pm trace stats location ' from that location. 'show tech-support vkgpm location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-4-ERR_SYSDB_EVENT ### Response: (Severity: 4), (Category: SECURITY), (Description: Sysdb subsystem sent a notification after a configuration change. This notification has an configuration change type that is not known to SSH. So, the configuration notification received has not been processed and configuration change applied.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_THOR_L2FIB-3-LTRACE_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the ltrace module in the platform L2FIB component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an IPv6 address on an interface? ### Response: To configure an IPv6 address on an interface, use the 'ipv6 address' command in interface configuration mode. RP/0/RP0/CPU0:router(config)#interface GigabitEthernet0/0/0/1 RP/0/RP0/CPU0:router(config-if)#ipv6 address 2001:db8::1/64 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-7-CAL_CHIP_WRITING ### Response: (Severity: 7), (Category: MGBL), (Description: Writing value to calendar chip at offset.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-6-RUN_MINIMUM ### Response: (Severity: 6), (Category: DIAG), (Description: Minimum Diagnostic is running on the card), (Recommended Action: Nothing. This is an informational message and the system is working properly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-7-SOCKET_INIT ### Response: (Severity: 7), (Category: IP), (Description: An software error occured when the TCP process do socket related initialization.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-3-DSP_IMG_CORRUPT ### Response: (Severity: 3), (Category: PLATFORM), (Description: --), (Recommended Action: Install the image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PM-3-RELOAD_LC ### Response: (Severity: 3), (Category: PLATFORM), (Description: The LC needs to be reloaded for the configured qos shaping granularity to be applied.), (Recommended Action: Exit the Config-terminal. Reload the Linecard using 'hw-module location reload' option.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-PCI_SWITCH_FAULT ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC FPGA detected fault on the PCI Switch device. This is an indication that one of the PCI Switch Port detected a Lane Down or Fatal Error condition. This can result in card going to POWERED_OFF state if the fault is persistent.), (Recommended Action: Try reloading the card using 'hw-module location <> reload'. If multiple card reload operation cannot fix the problem, check if physical OIR can address the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-6-PIFIB_MSG_TIMEOUT ### Response: (Severity: 6), (Category: OS), (Description: The PA failed to receive a response to a critical Pre-IFIB update.), (Recommended Action: This is handled by assuming that the update was installed but the response was dropped. The update may have not been installed due to failures which are detected elsewhere.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_TOPAZ-7-ERR_THREAD_MUTEX_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while creating a mutex for use by a client with the specified ID. This is crucial for the process and is automatically restarted on this failure.), (Recommended Action: If the problem is experienced only by this process in the system, restart the fabric server process by executing the following command at the CLI of the active RP: process restart fab_svr location If problem either persists (following a process restart) or also noticed on other processes then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_POLICY-3-ORA_BUILD_ERR ### Response: (Severity: 3), (Category: L2), (Description: There was an internal error in the routing policy library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-3-EVENTMGR_CREATE_FAILED ### Response: (Severity: 3), (Category: IP), (Description: The IPV6_MA process failed to create the event manager.), (Recommended Action: The process would recover itself from this error by itself as there is recovery mechanism. If the error is still seen restarting ipv6_ma may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BLWM-4-BATCH_CONFIG_REPLY_FAILED ### Response: (Severity: 4), (Category: OS), (Description: A BLWM-enabled server failed to send a reply about batch configuration to the client. The client might have restarted and this could be a transient error. Wait for the client to restart and reestablish connection with the server.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TP_SW-4-CLIENT_HB_TIMEOUT ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates that HB is timed-out for TP-LXC client), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR-3-EA_EVM ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates that the event processing infra has returned an error. Particular reason is included in the message.), (Recommended Action: Allow PBR EA to restart with the command process restart pbr_ea location If the problem persists, contact Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-1-ALL_FANTRAYS_OFF ### Response: (Severity: 1), (Category: PLATFORM), (Description: Two possibilities to this message 1) An alarm has occured. Software cannot access all fans from all trays. This could be caused by fan tray loss power or individual fans were not running. User will have 45 seconds to replace a fan tray. If no action is taken within 45 seconds, the chassis will be shut down. 2) A previously occured alarm has been cleared. Software has detected that all fan on all trays failed condition is cleared), (Recommended Action: Two possibilities to this message. 1) An alarm has occured : Replace or OIR a fan tray within 45 seconds. 2) A previously occured alarm has been cleared : *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: S2681-3-STATUS_MUTEX_UNLOCK_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The S2681 UART driver was unable to unlock the status variable for the interrupt thread.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-INSTDB_BUILD_ERROR ### Response: (Severity: 7), (Category: INSTALL), (Description: INSTDB files may be in an inconsistent state due to error encountered while creating them. This issue may affect sanity of install infrastructure data.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-NODE_SHUTDOWN_ON_MULTIPLE_RELOAD ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node has already undergone mutilple reboots and has reached node's reboot threshold limit of 6. In order to avoid further disruptions to the netwrok due to this node, its better to shut (power) down this node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-6-BEST_MASTER_CLOCK_REMOVED ### Response: (Severity: 6), (Category: L2), (Description: There is no longer a best master clock available to PTP.), (Recommended Action: This message is for information only, no further action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-5-INVALID_FLOW_TYPE ### Response: (Severity: 5), (Category: OS), (Description: The flow type information is not valid.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVM-4-HANDLE ### Response: (Severity: 4), (Category: OS), (Description: An Event Manager call was made with an invalid or corrupted event manager handle.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-INTF_REMOTE_CRITICAL_EVENT ### Response: (Severity: 6), (Category: L2), (Description: The remote peer has indicated a critical event.), (Recommended Action: No specific IOS-XR action needs to be performed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-EBS_CPU_FIFO_MBE ### Response: (Severity: 1), (Category: PLATFORM), (Description: EBS to CPU FIFO multiple bits error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_9_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias warning threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-7-MULT_DEFAULTIFIERS ### Response: (Severity: 7), (Category: SYSDB), (Description: Another process has already registered a default provider function on this path. It is not possible to have multiple default providers.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ETHER-3-SW_INTERFACE ### Response: (Severity: 3), (Category: L2), (Description: Internal software error in interface state.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rspp_rio_netio-3-CAPS_UNBUILDER_FAILED ### Response: (Severity: 3), (Category: SERVICES), (Description: The service ingress diversion NetIO DLL capsulation unbuilder function failed. Service ingress diversion in NetIO for the specified interface will not be removed from NetIO process.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-FANTRAY_VER_MISMATCH_CLEAR ### Response: (Severity: 4), (Category: PLATFORM), (Description: All fantrays are same version.), (Recommended Action: None required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-4-RESYNC_FAILED ### Response: (Severity: 4), (Category: SERVICES), (Description: An error has occurred following a restart of RSPP MA in the reconciliation of persistent data structures with the current configuration. Packet diversion may now be inconsistent.), (Recommended Action: Restarting RSPP MA may clear the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-DEBUG_CLEANUP ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when cleaning up debug.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-3-DATABASE_RESET_FAILURE ### Response: (Severity: 3), (Category: QOS), (Description: After a modify rollback failure, QoS EA will attempt to reset its database, but this reset attempt failed. The database for the said interface might be in an unknown state. Neither the old policy nor the new policy is applied in hardware for this interface.), (Recommended Action: Try removing the QoS policy on the interface for which this error message is printed from configuration, and then reattach the policy to the interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-3-VER_SET_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: bfm encountered an error and is not able to recover from the error. A reason text will be supplied call support with this text. An integer errno will also be printed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MRIB-3-MRID_REMOVE_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR_ENCAP-3-INIT_IFMGR_CONN_CREATE_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Process failed to creat a connection to Interface Manager while applying encapsulation config. This could be due to invalid or corrupt arguments being passed or memory allocation failure for which there is no current handling, therefore the system may now be out of sync.), (Recommended Action: Repeat failed configuration command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-4-SEND_FAILED ### Response: (Severity: 4), (Category: L2), (Description: Failed to send a message out of the given interface. The message has been lost, and will not be delievered to the remote peer.), (Recommended Action: Resynchonrisation mechanisms should ensure subsequent messages are correctly sent. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE affinity feature? ### Response: The MPLS TE affinity feature allows MPLS TE tunnels to select or avoid links based on link attributes called affinities or admin groups. Each link can be assigned one or more affinities, and tunnels can be configured with affinity requirements specifying which affinities to include or exclude. This provides granular control over tunnel paths. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_SOCKET-3-PACKET_CONN ### Response: (Severity: 3), (Category: L2), (Description: The fr_socket process failed to establish connection with packet manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: protect_debug-7-DUMP_HANDLE ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_PFILTER_EA-3-ERR_APPLY_ACE_MOD ### Response: (Severity: 3), (Category: L2), (Description: 1) An ACE modification can fail in apply/commit phase because of one of the following reasons: a) TCAM max limit has been reached. b) RLB resources are not available. c) IPv6 address compression table is full.), (Recommended Action: 1) When this error occurs the running-config will not be in sync with line card ACL hardware programming. 2) If the ACL could not be removed from hardware a line card reload is recommended.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMGR-4-VM_INSTALL_STATUS ### Response: (Severity: 4), (Category: OS), (Description: VM install/upgrade/unistall status.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-3-THREAD_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: One of the threads for statistics collection could not be started.), (Recommended Action: This message will be displayed immediately before the failing process restarts. The restart may clear the issue. If it does not, then the following action should be taken. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_FI_INTR_RCTL1_LO_EOP_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_FI_INTR_RCTL1_LO_EOP_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-INSTALL_IS_TO_SUSPEND ### Response: (Severity: 4), (Category: INSTALL), (Description: The incremental install operation will be suspended indefinitely, at the pre-defined suspension point. User needs to issue 'install resume' in admin mode in order to resume the operation.), (Recommended Action: Do 'install resume' in admin mode, whenever ready.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XFP-2-DEV_XFP_SUPPORTED_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: An XFP supported error was detected during XFP initialization. This error is reported when the XFP type can not be determined or it is not supported on the platform. The XFP is the pluggable optics on the line cards. XFP initialization may happen when linecard boots up, XFP OIR and line card process restart. The optics will not be enabled if an XFP supported error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the XFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_QOSEA-3-AGG_BUN_HW_REPROG_ERROR ### Response: (Severity: 3), (Category: QOS), (Description: There has been an internal error while reprogramming HW resources as a result of bundle membership changes.), (Recommended Action: *SUPPORT* *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-MAX_ENABLE_RETRY ### Response: (Severity: 3), (Category: ROUTING), (Description: Reached the maximum number of retries to enable multicast and), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_HW-2-ERROR_TLU_ALLOC ### Response: (Severity: 2), (Category: ROUTING), (Description: Hardware memory allocation for table lookup unit (TLU) failed. This can be because the system has more forwarding entries than supported limits or there is a software defect.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-bandwidth underflow feature? ### Response: The MPLS TE auto-bandwidth underflow feature allows auto-bandwidth to react more quickly to drops in traffic flow by triggering an immediate bandwidth adjustment when the measured rate drops below a configured underflow threshold. It aims to free up bandwidth on the tunnel path more promptly when traffic decreases significantly. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CSI_EA-3-INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: This is an informational message in the CSI EA to indicate that an error was seen during init operation. A return code is returned which can do a retry or exit based on if error persists.), (Recommended Action: Please collect the console log,) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: aaa_task-3-DEBUG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Error message from AAA task debug module), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_MIB_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the DLL. This resulted in the DLL not being loaded into the SNMP agent, and thus the MIB services will not be available.), (Recommended Action: Restart the snmp process reporting the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-7-UNBIND_MTD_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Unbind MTD failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_LOCSW-6-INIT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the platform L2FIB LOCSW component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-5-SESSION_PROTECTION ### Response: (Severity: 5), (Category: ROUTING), (Description: An informational LDP notice was generated for a Session Protection event. This message appears only if the mpls ldp log session-protection command is configured.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-ERR_DLL_UNKNOWN_FUNC ### Response: (Severity: 3), (Category: MGBL), (Description: 'An error occurred when trying to locate the dll function in DLL.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STANDBY-6-INFO_HOLDTIME ### Response: (Severity: 6), (Category: IP), (Description: The holdtime has been set to a value which is less than (or equal to) twice the hello time. This is not recommended as any lost packet may result in an unnecessary state change.), (Recommended Action: Change the holdtime to be greater than twice the hellotime.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-INVALID_ORDER ### Response: (Severity: 3), (Category: MGBL), (Description: Nvgen server obtained an incorrect order list entry from an internal order file. This may result in the show run output to have a different ordering than intended.), (Recommended Action: Collect the show version, show logging, show nvgen trace output, show runnning output, show config history and show tech-support sysdb. Contact TAC representative with this information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-INSTALL ### Response: (Severity: 3), (Category: ROUTING), (Description: Error while performing upgrade/downgrade/install operation), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE6_CODE_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE6_CODE_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MADISORN-4-EVENT_WARNING ### Response: (Severity: 4), (Category: OS), (Description: An invalid event was recieved. These are ignored.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_BAT_FAIL_B ### Response: (Severity: 2), (Category: PLATFORM), (Description: The CPT 50 Shelf Battery Failure B alarm occurs when battery B is down or not detected. This could be because the battery is removed or is not operational.), (Recommended Action: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-XBAR_TIMEOUT_ERROR_LNK1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected an crossbar timeout error on link 1), (Recommended Action: This alarm is transient and should auto-clear when error condition is resolved. If the alarm doesn't clear, then please reload the card using command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-6-INTF_OIRIN ### Response: (Severity: 6), (Category: PLATFORM), (Description: SFP or XFP or CFP or QSFP entity is inserted into the line card.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the LDP IGP Sync feature in Cisco IOS XR? ### Response: The LDP IGP Sync feature ensures that LDP is fully operational on a link before the link is used for forwarding traffic. It prevents traffic loss during IGP convergence by delaying the use of a link for forwarding until LDP has converged on that link. This feature is enabled using the 'mpls ldp sync' command under the interface configuration mode. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-XAUI_0_FRAG_ERR_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: XAUI interface to NPU-0 reported fragmentation error on TX side on bridge instance - 3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-ISSU_ERR ### Response: (Severity: 0), (Category: PLATFORM), (Description: Network Processor Initialization encountered a critical error on V2 that renders the ISSU to abort.), (Recommended Action: Abort the current ISSU and repeat the ISSU orchestration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO_API-3-LTRACE_BUFF_CREATE_INIT ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Trace buff add failed as trace initialization is not done.' 'process will continue without any error.'), (Recommended Action: 'Trace initialization will be done and then this buffer wil be addded.' 'If error persists.Collect the error log with return value' 'and core dump of the process and contact tac') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-3-ANR_WHITELIST_FILE_ERROR ### Response: (Severity: 3), (Category: SERVICES), (Description: 'The autonomic registeration authority encountered ' 'file error when reading from whitelist file, ' 'check the file name and its contents'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-5-UNSIGNED_PACKAGE ### Response: (Severity: 5), (Category: OS), (Description: A software package without a code signing certificate has been loaded.), (Recommended Action: Take note of the service container and software package. Verify the software package is expected to be unsigned and has the appropriate contents. Uninstall the package if unsure of the package origins.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-2-FAB_LICENSE_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature is enabled without having valid license. This feature is per RSP3-Lite based, so in a HA setup 2 licenses required. In stand alone setup 1 license is enough. Use 'admin show license' CLI to check license status.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FT-4-FAN_TRAY_0_REMOVED ### Response: (Severity: 4), (Category: LIBRARY), (Description: FT0 removed, FT1 and FT2 OIR won't be detected in absence of FT0. Insert FT0 back.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_IO-3-PA_NULL_HANDLE ### Response: (Severity: 3), (Category: IP), (Description: The ipv4_io process was given a NULL handle by the port arbitrator.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVSAT_CTRL-4-RESPAWN_THRESHOLD_EXCEEDED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The Control process has exited and respawned too many times in factory mode. This prevents satellite mode from operating correctly, so the router will enter standalone mode.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-4-FAIL_MEM ### Response: (Severity: 4), (Category: SERVICES), (Description: CGN modules are failed to allocate memory due to low memory conditions in the System.), (Recommended Action: Increase System Memory or stop some applications which are not required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCTRL-6-POWER_UP_DATA_ZONES ### Response: (Severity: 6), (Category: LIB), (Description: 'Request sent to power up data zones'), (Recommended Action: Check if card shows OPERATIONAL in show platform) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-USER_NOT_AVAILABLE ### Response: (Severity: 4), (Category: SNMP), (Description: SNMP user configured with aes and 3des encryption will be available for snmp operations only if crypto pie is installed on the router. Though the user config will be available in the router, user will not be operational.), (Recommended Action: If snmp user with 3des and aes encrypiton is required for snmp operation then please install crypto pie on the router.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-INIT_RLB_CKPNT_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failed to initialize RLB (range logic block) checkpoint. This is needed for checkpointing range logic block information for restore on process restart.), (Recommended Action: No action is required. Process will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If restart din't fix the problem) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-1-SYNC_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Fabric arbiter detected link sync error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-CHKPT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The reason should be supplied in the IOS msg itself, but basically this message means that shelfmgr usbale to update HA cheackpoint.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAP-3-FATAL_ERROR_CAPI ### Response: (Severity: 3), (Category: INFRA), (Description: A fatal error occurred in CAPI communication. Note the reason for the error.), (Recommended Action: Root cause of the error needs to be determined.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_NTP-5-HP_CONN_LOST ### Response: (Severity: 5), (Category: IP), (Description: The ntp server lost the connection with a high-priority clock source. The Stratum tells the change of server stratum.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-3-CONNECT_DETACH ### Response: (Severity: 3), (Category: OS), (Description: SSM process tried to detach to the clients channel using ConnectDetach api and encountered a failure.), (Recommended Action: Collect system log information for the reported service and pid. Collect show process , follow process , show process blocked Collect show tech ssm. If this message is seen repeatedly, capture the output of debug event-manager all job . 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you monitor interface statistics in Cisco IOS XR? ### Response: Interface statistics in Cisco IOS XR can be monitored using the 'show interfaces' command. It provides information about interface status, packet counts, error counts, and other performance metrics for each interface. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-SERVICE_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA driver was not able to connect to the service with the above error condition.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-INVALID_IDPROM_DATA ### Response: (Severity: 4), (Category: DRIVER), (Description: CCC driver detected invalid data in IDPROM content. This can happen only with protoype boards that did not get correctly programmed.), (Recommended Action: Content of the IDPROM will have to be fixed to avoid seeing this warning message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-CDMA_RAM_PARITY_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Indicates an uncorrectable parity error occurred on this internal SRAM. %s - name of ram that error occurred %x - key of error node recorded %s - error data), (Recommended Action: Ignore the message if appears only once. Otherwise reload the board Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-DELAY_ASYM_CHANGE ### Response: (Severity: 4), (Category: PLATFORM), (Description: PTP is phase locked to the remote PTP server and user has changed the delay-asymmetry configuration. The change in asymmetry can cause PTP servo to temporarily unlock to apply the necessary phase adjustments.), (Recommended Action: No further action is needed. If PTP unlocks, then it shall eventually phase-lock to the remote PTP server again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_MCAST-3-ERROR_RT ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM MCAST, error), (Recommended Action: Please collect the console log, multicast traces (show mfib trace loc <>, show mfib hardware ltrace location <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFEA_IPV6_EA-3-CRITICAL ### Response: (Severity: 3), (Category: PLATFORM), (Description: AFEA IP-EA, Critical error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-RSPI_PHY_LOSS_SYNC ### Response: (Severity: 1), (Category: PLATFORM), (Description: RxSPI Phy lost sync.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-PVT_POOL_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath encountered an initialization error A reason text will be supplied to describe the error. This error could occur for two reasons. 1. The system is low on resources. 2. A hardware error or an error in the DPAA software.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect show log location output, show controllers dpaa trace all location output and show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-4-WARN_ERR ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is an severe error message in the OFA module to indicate that an error was seen during init operation.), (Recommended Action: Please collect the console log, OFA traces (show ofa trace loc <>), Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_TF_INTR_FIFO_1HI_OVFL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_TF_INTR_FIFO_1HI_OVFL interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD_NETIO_TOPAZ_DLL-3-INVALID_PORT ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: FWD was supplied with a plim port or uidb index that exceeds the limit of num ports.), (Recommended Action: No Action required Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-CARD_SEATED_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: IOFPGA has detected that the card is not being seated correctly in the backplane of the chassis. This problem is preventing the card from booting.), (Recommended Action: Reseat the card to correct the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-0-CRC_ERROR_FATAL ### Response: (Severity: 0), (Category: PLATFORM), (Description: CRC rate above acceptable level), (Recommended Action: The board would get reloaded. On reload of board, run following commands from RSP ksh to decode PCDS information - pcds_decode -c NIANTIC <.pcds file>. If users has auto reset option disabled in admin config, then the board would not get reloaded on its own. At this stage collect the output of (admin)'show tech-support control-ethernet location file outputFile') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-REPOQUERY_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: An error has been encountered when using repoquery. While the issue is seen, the install process cannot query all repositories (configured or internal) and so information regarding the repositories may be missing to the user. This can sometimes be seen during a system upgrade for a short period (less than a minute) with no impact to the system. If this issue is seen repeatedly over an extended period of time, then there may be an issue with the packaging manager. This will not impact routing, but should be investigated before any further install operations are performed.), (Recommended Action: If seen during a system upgrade, then this syslog can be ignored as long as the upgrade completes successfully. If the issue should be investigated: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-5-SYSCALL ### Response: (Severity: 5), (Category: HA), (Description: A system call failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-SEMFAIL ### Response: (Severity: 3), (Category: SNMP), (Description: SNMP ncurred an internal software error. This error indicates sysnchronization lock create failed), (Recommended Action: Restart process which causes failure senario. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-CCTL_ECM_SYSDB_REG ### Response: (Severity: 3), (Category: PLATFORM), (Description: Creating/opening ECM connection to SysDB for registering notification on this connection failed as mentioned in the mesage.It will retry to register again.This is not a major failure,system will continue to work.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-SOFT_ERROR_ALERT_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Soft error detected on Bridge FGPA instance 0.), (Recommended Action: Please reload the board in the next maintenance window. Until then affected ports will be down. 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-3-HARD_HIGH_WM_EXCEED ### Response: (Severity: 3), (Category: FABRIC), (Description: --), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARB-7-ERR_LWM_REPLY ### Response: (Severity: 7), (Category: PLATFORM), (Description: Arbiter driver LWM reply error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-5-NSR_PEER_SYNC_LOST ### Response: (Severity: 5), (Category: ROUTING), (Description: LDP Non-stop routing synchronization to standby RP node has been lost for the peer. This message appears only if the mpls ldp log nsr command is configured.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-DISK_IMAGE_PATH ### Response: (Severity: 3), (Category: OS), (Description: The virtual service machine definition file contains an invalid disk image path for one of the disk devices. This may be a Harddisk, CDROM or USB storage device.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFC_WATCHDOG-5-EXPIRED ### Response: (Severity: 5), (Category: PLATFORM), (Description: Priority Flow Control (PFC) packets have been continually received and the queue has been stopped for the given watchdog interval.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_0_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser bias less than or equal to the low laser bias warning threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to set RSVP policy for TE tunnel in Cisco IOS XR? ### Response: To set an RSVP policy for a TE tunnel, use the 'tunnel mpls traffic-eng policy' command in interface configuration mode. RP/0/RSP0/CPU0:router(config-if)#tunnel mpls traffic-eng policy Policy1 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-LRD_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show mpls traffic-eng tunnels' command in IOS XR? ### Response: The 'show mpls traffic-eng tunnels' command is used to display information about MPLS TE tunnels. It shows the tunnel name, destination, state, setup and hold priorities, bandwidth, and the path used by the tunnel. This command is useful for verifying the state and attributes of TE tunnels. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_HFR-4-ERR_NETIO_CONN ### Response: (Severity: 4), (Category: PLATFORM), (Description: Cannot connect to netio pak server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_12_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: An unrecoverable error occurred at system initialization time.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-3-ERR_SYSDB_DELETE ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND_LITE-3-SHMEM_UNAVAILABLE ### Response: (Severity: 3), (Category: L3), (Description: The IPv6 Neighbor Discovery (ND) spoofing process (ipv6nd_lite) has been asked to handle more interfaces than it is built to support. This error alone will not prevent the router from working, but since ipv6nd_lite is used to maintain service during restarts of ipv6_nd, it may cause the router to become momentarily unreachable by other routers during restart. The error results from a misconfiguration.), (Recommended Action: Reduce the number of virtual interfaces configured.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSI_AGENT-3-GENERAL_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Some requested operation failed. The text of the message displays the failed operation with error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-6-THRESHOLD_NO_CLEAR ### Response: (Severity: 6), (Category: INFRA), (Description: The specified SLA threshold was breached, but is no longer breached. However, the bucket in which it is no longer breach is considered suspect, and therefore the threshold state, and action that was taken on breach, has not been cleared.), (Recommended Action: The threshold clear may or may not be related to the suspect bucket. Therefore, wait for the next non-suspect bucket to determine whether this is a genuine threshold clear or not.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-4-PASSWD_ALREADY_EXISTS ### Response: (Severity: 4), (Category: SECURITY), (Description: An internal software error has occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-UNRECOVERABLE_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: The host CPU on the line card has detected a fatal non-recoverable error on one of the network processors. The affected NP will be shut down without LC reload.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-2-NP_DIAG ### Response: (Severity: 2), (Category: PLATFORM), (Description: Self diagnostics has detected NP packet processing problem. Automatic recovery action will be attempted. Further alarm will be raised if automatic recovery attempts fail.), (Recommended Action: Recoverable error. Reboot linecard. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-LSP_REROUTE_PENDING_CLEAR ### Response: (Severity: 5), (Category: ROUTING), (Description: The specified interface is fast-reroute enabled and in UP state; earlier path verification failed but it did not take down the interface and got into reroute-pending state. Interface is now getting out of re-route pending state as a result of reoptimization or CLI changes.), (Recommended Action: None. This is a solicited message (by 'logging event lsp-status reroute' \ interface configuration).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSMGR-3-INTERNAL ### Response: (Severity: 3), (Category: OS), (Description: The client library has failed a sysmgr function.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-FALAFEL_PON_RESET ### Response: (Severity: 3), (Category: FABRIC), (Description: The falafel device failed due to the above mentioned error. The device is being reset (PON) to recover from failure), (Recommended Action: Collect all the event logs and the output of the following commands executed from the CLI of the active RP if the asic is continuously reset and recovery does not take place after device reset: 1. 'show processes sfe_driver location ' 2. Collect all traces: 'show controller sfe trace all location ' 3. dmesg and /var/log/messages from host and sysadmin VM If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN_EA-3-ERROR_INTERNAL ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error was detected in the Platform SPAN module which causes the span module to exit. The reasons might be *Failed to initialize the shared memory AVL tree *Failed to get local source port *Failed to delete AVL entry tree *Failed to initialize debug and ltrace events), (Recommended Action: No action is required. Process will try to restart automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_0_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Rx power less than or equal to the low Rx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Rx power threshold values are read from the QSFP+.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HPI-3-SHM_DEVICE_MEM_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to allocate memory using shared memory handle of the HDI device client. %s-Function name. %s-Error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_VRFNSUSP ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_ENCAP_DB-2-TUN_NOTFOUND_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: tunnel entry not found in avl tree), (Recommended Action: The following needs to be collected and DE team to be contacted. show encap-id platform egress-db all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-3-MSG_SIZE_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBQSMGR-1-SEND_READY_FAILED ### Response: (Severity: 1), (Category: INSTALL), (Description: The communications channel to QSU Manager is unavailable.), (Recommended Action: The process is automatically restarted, which should trigger a QSU abort - the QSU may be attempted again at this point. If this process is involved in protocol operation, then there may have been packet loss as a result of this event which requires remedial action. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCM_SWITCH-2-PCI_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: The switch encountered a PCI error during a DMA transaction. Process will restart by itself to recover from the failure. After the bcm_process restarts, the error will be cleared.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ROMMON_BURNER-3-BAD_ARG ### Response: (Severity: 3), (Category: PLATFORM), (Description: Bad coammand option.), (Recommended Action: No action is required..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-SYSDB_ITEM_GET_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-RSA_PUBLIC_KEY_NOT_FOUND ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to query RSA key.), (Recommended Action: 'Check the subject name in the certificate.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_TOPAZ-3-ERR_PKT_DROPPED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Could not send pkt to QAD and it is dropped. %d- reason for the pkt drop. %s- error type.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_UV-3-ERR_SYSDB_CONNECT ### Response: (Severity: 3), (Category: ROUTING), (Description: The ospf_uv process was unable to bind to SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-2-ERR_THREAD_DEADLOCK ### Response: (Severity: 2), (Category: ROUTING), (Description: BGP detected a lock being held when all locks should have been released.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_MPLS_EA-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: DNX MPLS-EA, Debug information), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-5-YVE_DEBUG_ERROR ### Response: (Severity: 5), (Category: MGBL), (Description: An error was encountered while the Central Configuration Validator (CCV) was processing a request from the command line for YVE debug.), (Recommended Action: The problem may be caused by failure to find the requested rule or node in the YVE database. In this case, check that the parameters are valid.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-HIGH_TEMP ### Response: (Severity: 3), (Category: FABRIC), (Description: The POD detects a high temperature. The POD might not be functioning properly, and can cause cell drops or corruption in the rx or tx link associated with the POD.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SUBS_AIPC_UTIL-4-TRACE_INIT ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This is a non-fatal error in initializing tracing buffer and can happen when the router is low on memory. It should not affect the functioning of the router, but trace messages may not be logged.), (Recommended Action: Check the memory state of the ltrace process and overall system. Reduce the activities on the system if required for tracing.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TURBOBOOT-3-DISK_TOO_SMALL ### Response: (Severity: 3), (Category: INSTALL), (Description: Disk is too small for easybake to continue on.), (Recommended Action: Based on the error message check the required number of bytes for IOS XR software and replace the disk with one that has equal or more number of bytes.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-4-IIR_QUERY ### Response: (Severity: 4), (Category: OS), (Description: Hardware pre-ifib returned an error during a batching operation.), (Recommended Action: Restarting pifibm_server_lc may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ROULETTE-3-MEM_CORRUPT_TX_REQUEST_ARRAY ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message related to the Canbus Controller processing the received UART message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ bias less than or equal to the low laser bias warning threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GDOI-3-SVC_ERROR ### Response: (Severity: 3), (Category: OS), (Description: A service API failed and error is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERG-5-ROLE_ACTIVE ### Response: (Severity: 5), (Category: INFRA), (Description: The SERG role from the concerned group has change to ACTIVE from either MASTER or SLAVE or uninitialized role. This is a normal redundancy event.), (Recommended Action: None required if there has been any network event or administrative action that caused this redundancy role change. Session status may be checked on both active routers to verify consistency, if desired.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-3-SIA_UPGRADE_BLOCKED ### Response: (Severity: 3), (Category: LICENSE), (Description: Software upgrade is blocked. Please check show license platform summary/detail for more information.), (Recommended Action: Rectify the SIA Out of Compliance as soon as possible.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-7-REMOVING_SHM ### Response: (Severity: 7), (Category: HA), (Description: While initialising Checkpoint. Process is removing shared memory segments .), (Recommended Action: Debug message only. No action required. This message is to report state of process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-3-IO_ERROR ### Response: (Severity: 3), (Category: L2), (Description: Egressq ASIC encountered a read or write access error or its Host Processor Interface block has gone down and come back up. The access error is classified into two classes - software or hardware. Hardware access error refers to an error at the PCI link used to connect the ASIC to the host processor. Software access error refers to the error, caused by a un-discovered software bug, which makes software to perform un-supported access to an ASIC location, like writing to a read-only location.), (Recommended Action: If the message indicated this is a hardware access error, software will have automatically taken action to recover from the error. If harware access error does not recur, no other action is required. If the hardware access error persists or it is a software access error, copy the System Message exactly as it appears on the console or in the system log, enter command 'show tech-support controller egressq location <>', report the error to your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_22 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_SYSMGR_MON_LIB-3-SYSMGR_MONITOR_TMP_CORECOUNT_OPEN_FAILED ### Response: (Severity: 3), (Category: HA), (Description: vm-monitor sysmgr tmp coredump count file open failed), (Recommended Action: This indicates an vm-monitor process is hung or unable to communicate with sysmgr.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-6-LOG_INFO ### Response: (Severity: 6), (Category: OS), (Description: An Info message logged.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE1_CODE_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE1_CODE_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-PORT_FWD_ERR_GENERAL ### Response: (Severity: 3), (Category: SECURITY), (Description: SSH port forwarding encounterd some error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS VPN extranet feature? ### Response: The MPLS VPN extranet feature allows MPLS VPN service providers to distribute routes across VPN boundaries. It enables a VPN to share common routes with other VPNs, providing controlled access between VPNs. Extranet VPNs are implemented by configuring route targets to be imported and exported between VPNs that need to share routes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the 'install replace' command in Cisco IOS XR? ### Response: The 'install replace' command in Cisco IOS XR replaces the current software with a new version, effectively performing an upgrade or downgrade of the system software. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-3-BAG_FAILED ### Response: (Severity: 3), (Category: OS), (Description: Bag api call failed.), (Recommended Action: Please collect the output of the following commands: - show tech-support lpts - show tech-support sysdb - show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP Routing Policy Language (RPL) on IOS-XR? ### Response: The Routing Policy Language on IOS-XR is used to define routing policies to filter and modify BGP path attributes. It provides a rich and flexible policy definition language. RPL policies are defined separately from the BGP process and applied using the route-policy command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ_MGR-7-ERR_DLL_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabricq driver tried to register for a dll but it encountered an error. The driver might lose some of its functionality.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GRID-4-BANK_FULL ### Response: (Severity: 4), (Category: L2), (Description: All the network resources associated with this BANK have been completely exhausted and GRID is unable to allocate more rids), (Recommended Action: The network operator could try and reduce the scale which would free up the rids . For eg. 1. If the GLIF bank 0 is full, reduce the ARP entries / adjacencies 2. If the GLIF bank 1 is full, reduce the labels) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-3-STATE_CHANGE ### Response: (Severity: 3), (Category: MGBL), (Description: The node on which the process is running has changed state, but the process was not able to change the mode in which it is running to reflect this. The most likely reason for a state change of this type is an RP failover.), (Recommended Action: This message will be displayed immediately before the failing process restarts. The restart may clear the issue. If it does not, then the following action should be taken. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-QSM_ERROR ### Response: (Severity: 3), (Category: OS), (Description: The server failed in advertising its namespace through QSM), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_STORE_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS was unable to perform the specified operation on the specified interface. This is most likely to be a resource starvation problem, but may be an internal programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the IS-IS process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-UNKNOWN_RP_BOARD ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the board type cannot be recognized, therefore, the node will not be able to boot up. This may be caused by an invalid eeprom content; or happens in a rare corner case which may recover after a board reset.), (Recommended Action: Two possibilities to this message. 1) The board boots up after resets beacuse of boot request timer timeout : *None* 2) The board does not boot up after resets : Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM_COMMON-4-WRITE_ABORT ### Response: (Severity: 4), (Category: MEDIA), (Description: A Write to nvram was aborted.), (Recommended Action: Recovery will be attempted in the driver. Otherwise format nvram using command - erase nvram: format) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSVDPMEM-3-INVALID_PARAMS ### Response: (Severity: 3), (Category: OS), (Description: Reserve Physmem encountered a severe error and is not able to recover from the error. Details are provided with the error message. Call support with this error message text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GATM-2-ERR_HEX ### Response: (Severity: 2), (Category: L2), (Description: Error in gatm operation. Error message here describes that the gatm method was expected to succeed, but failed somehow as either the attribute fetch/ operation corresponding to the interface handle(in parenthesis) did not succeed Or, the ifhandle itself was invalid.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_4_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-6-TEST_SKIPPED ### Response: (Severity: 6), (Category: DIAG), (Description: The specified diagnostic test cannot be run.), (Recommended Action: Nothing. Although the test cannot be run, this message does not indicate a problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB_LIB-3-ERR_SHM ### Response: (Severity: 3), (Category: L2), (Description: Some error occurred in operations related to Shared Memory area such as Shared Memory lock/unlock, Shared Memory corruption, memory allocation or freeing Shared Memory. This could have occured due to overuse of memory. This can result in- 1) Not programming hardware for proper forwarding. 2) Not creating new bridge.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_REDDRV-3-ERR_DCMD_PSARB_DRP_HACK ### Response: (Severity: 3), (Category: PLATFORM), (Description: Please refer the error string for more detail. Software will automatically do recovery by restarting the reddrv process.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_ABORTTRANS ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB-7-ERR_EVENT_CONN_NOTIFY ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to register event handler for disconnection or connection error event. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-MSGQ_CREATE_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Creation of above message queue failed.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-4-TCP_KEEPALIVE ### Response: (Severity: 4), (Category: IP), (Description: The TCP keepalive timeout was not set during initialisation. The default value of 2 hours will apply. Telnet will otherwise function normally.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The router can continue to be used.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_EA-3-PLATFORM_UPDATE ### Response: (Severity: 3), (Category: IP), (Description: An error occurred while trying to update the platform code with information about the interface whose handle is contained in the message.), (Recommended Action: The update will be replayed to the platform code and may succeed on a subsequent attempt. If not then the system will be left in an inconsistant state and this interface may not function normally. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_8_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias less than or equal to the low laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-CHKPT_REMARK_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Un-able to remark valid FGID's during MDR), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-6-SERVER_BUSY ### Response: (Severity: 6), (Category: MGBL), (Description: A lock operation on shared resource, called by nvgen failed due to the mentioned error.), (Recommended Action: Collect the output of show logging and inform Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-SPKR_RUNNING ### Response: (Severity: 4), (Category: ROUTING), (Description: The bpm process was terminated improperly and the speaker process did not receive the notification to terminate. A new bpm process has started with a different AS number due to a new bgp configuration while the speaker process is still running with the previous AS number.), (Recommended Action: The speaker will be restarted to handle this error. No further corrective action is necessary. However, please contact your Cisco technical support representative to report this error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-RSP_ISOLATED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that the RSP is in an isolated state from the rest of the router. This means it is held in isolation for the collection of debug information and will be subsequently rebooted by software automatically.), (Recommended Action: None is required, this message is informational.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_API-3-TLVLIB_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that Shelf Manager TLVLIB init operation has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_UNEXPECTED_CLEANUP ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA is trying to cleanup a session when it is in an unexpected state. The error message describes which state it was in, and what was triggering the cleanup. This is most likely to be a programming error, either in PPPoE or in one of the processes it interacts with.), (Recommended Action: PPPoE MA should recover by itself.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SUSTAINED_CRC_ERR ### Response: (Severity: 1), (Category: FABRIC), (Description: Fabric interface ASIC is reporting a sustained rate of CRC errors.), (Recommended Action: Check for other failures like online diags. Reload the board to see if the error goes away. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRv6-5-MICROSEGMENT_OUMERGE_MODE_CHANGE ### Response: (Severity: 5), (Category: ROUTING), (Description: The default mode of operation on this platform is NOT to do merge of uSIDs from overlay and underlay into a single uSID carrier. This mode can be changed to 'merge' by configuring segment-routing srv6 micro-segment merge-overlay-underlay-sids command. However, the configuration change applies only to any new SRv6 overlay getting programmed onward in RIB/FIB.), (Recommended Action: To trigger re-programming of existing SRv6 overlay prefixes in RIB/FIB after any change to this config, please flap those routes by clear route [vrf <>] { ipv4 | ipv6 } unicast. If this config is applied at the time when no SRv6 overlay prefixes are programmed in RIB/FIB, no action needs to be taken at the config change.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: action-3-PEG1MSG ### Response: (Severity: 3), (Category: OS), (Description: This is a test message for action->peg message), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-6-BOOT_REQ_RECEIVED ### Response: (Severity: 6), (Category: PLATFORM), (Description: Logging the Boot Request Rommon Version), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_HAL-3-ERROR_RT ### Response: (Severity: 3), (Category: PLATFORM), (Description: This error message indicates error in PLATFORM FIB HAL), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show logging, show version, show platform, show install active, show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_LOS_PORTS ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-1-RX_ILKN_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Ingress MUX encountered Rx interlaken core error.), (Recommended Action: This fault would result in traffic loss. Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-4-COND_TIMED_WAIT ### Response: (Severity: 4), (Category: OS), (Description: In RDS library we tried to wait using the pthread_cond_timedwait but the pthread_cond_timedwait failed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_UV-3-INTF_FWS_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: The ospf_uv process was unable to initialize the forward-reference store library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_BURNER-3-FILE_OP_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error occured with file operations.), (Recommended Action: No action is required..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_TDM-7-REG_MISMATCH ### Response: (Severity: 7), (Category: HA), (Description: An application is trying to register for its table. A table with the same name and version exists, but other attributes have changed, so the table is not allowed to be used.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_NSR-3-SPR_NSR_MEM_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: sprayer + NSR headers memory allocation failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_EDM-3-EVENT_REGISTRATION_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: The process failed while attempting to connect to an event manager channel for the indicated subsystem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-SEND ### Response: (Severity: 7), (Category: SYSDB), (Description: The SysDB server failed to send an asynchronous message to a SysDB client. A likely reason for this is that the process in question has exited.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show process location all command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show process location all output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-LS_LFI_DISABLED_TYPE_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected a lfi disabled type error), (Recommended Action: Please try to correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-3-ERR_SET_REBOOT_CAUSE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The failure on setting reboot cause to syspage before performing Kernel Dump.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-3-lsp_verify_lsp_absent ### Response: (Severity: 3), (Category: OS), (Description: Unable to update LSP due to absense of LSP), (Recommended Action: Check LSP name specified in EXEC CLI) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-AMBIGUOUS_MAC_SYNC_ROUTE ### Response: (Severity: 3), (Category: L2), (Description: If a sync route is received with no attachment circuit ID extcomnm, bridge port stamping is done on a best-effort basis. If exactly one bridge port is found matching this EVI and ESI, it will be used to program forwarding. Otherwise, the sync route is considered to be ambiguous and is dropped.), (Recommended Action: Review evpn and l2vpn configuration to determine where additional forwarders (bridge ports) have been configured for the same interface ethernet segment and same EVI, and remove them or configure the EVI with AC aware VLAN bundling. If a AC aware vlan bundling is used, ensure that the configuration is matching on the peer router.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STANDBY-6-INFO_STATECHANGE ### Response: (Severity: 6), (Category: IP), (Description: The HSRP router has changed state for the specified group and interface.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is a PIE in the context of IOS XR? ### Response: In the context of IOS XR, a PIE (Package Installation Envelope) is a modular combination of components that identifies a set of features a user wants to run on the router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the OSPF Hello protocol? ### Response: The OSPF Hello protocol is responsible for establishing and maintaining neighbor relationships. Routers send Hello packets out each OSPF-enabled interface to discover neighbors. The Hello packet contains information about the router's OSPF priority, router dead interval, designated router, and backup designated router. Routers become neighbors if certain information in their Hello packets match. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR node protection desired feature? ### Response: The MPLS TE FRR node protection desired feature allows link protection to be used even when node protection is configured on a tunnel. It provides a way to prefer node protection but use link protection as a fallback. The tunnel is protected if possible, but a best-effort approach is used otherwise. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_FM-6-FIELD_IGNORED ### Response: (Severity: 6), (Category: L2), (Description: User is trying to use a classification criterion not supported by the feature. For example, user is trying to apply a with a class matching matched on an IPv6 ACL that contains a match on flow-label. The entire rule (e.g. ACE) containing the unsupported criterion is ignored. In our example, only the ACEs containing match on flow label are ignored. All other ACEs are still downloaded to CPP.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_SSE-3-ERR_SYSDB_EDM_REG ### Response: (Severity: 3), (Category: L2), (Description: The bfd_agent was unable to become an external data manager (EDM) for the specified path. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective MSC reboot.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BLWM-4-REPLY_PROCESSING_ERRORS ### Response: (Severity: 4), (Category: OS), (Description: A failure occurred while processing the batched replies received from the server. This is most likely an internal error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_6_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-5-NBR_LOST ### Response: (Severity: 5), (Category: SERVICES), (Description: 'Lost connectivity to the neighboring device & ' 'it is no longer part of autonomic domain'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-EPCFRR_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured while processing TI LFA. The error is unexpected & nonfatal.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-DEBUG_SPECIFIC_SET ### Response: (Severity: 7), (Category: OS), (Description: This is a debug message that is not compiled into a customer version of the code.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA_CAPI_SERVER-3-IOFPGA_ERR ### Response: (Severity: 3), (Category: INFRA), (Description: IOFPGA has asserted a Error wrt power sequencer, for exact info view the '%s' msg displayed.), (Recommended Action: This is an informational message.This indicates fault with power sequencer as displayed in syslog message. Can be ignored on first occurence of msg. In case of repeated msg contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-INVALID_IP ### Response: (Severity: 3), (Category: SERVICES), (Description: The ip address is invalid.), (Recommended Action: This is a serious error and the function returns from there.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-3-SPAN_BUFFER_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An error was encountered while writing to the buffer.), (Recommended Action: This problem may indicate there was an issue with writing to internal buffer. You can reconfigure SPAN and try again. If problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAK-3-MUTEX_DISALLOWED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An attempt was made to lock the packet mutex from a thread where mutex locking is disallowed), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFD_HELPER-6-STATE ### Response: (Severity: 6), (Category: MGBL), (Description: An change state occurred in the confd_helper.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-X86_XFORM_BEFORE ### Response: (Severity: 7), (Category: HA), (Description: To print the values before conversion.), (Recommended Action: X) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-7-GENERIC_TILE_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: A generic error occurred in Tile Manager. Cause of the error will be mentioned in the message displayed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR_API-6-API_RET_VAL ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is informational message to indicate return value of api.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VERSMGR_LIB-7-PARAMETER ### Response: (Severity: 7), (Category: INSTALL), (Description: A client of a Version Manager library passed it an invalid argument, and so the library may not be able to carry out its operations. Installations may not produce all the expected results.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOADPATH_UPGRADE-7-CANT_ACTIVATE_ON_NODE_TYPES ### Response: (Severity: 7), (Category: INSTALL), (Description: Instructions in package conflict with requested operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_PLIM_SB-3-FPD_IMG_UPD_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The FPD image update operation for the indicated device has failed. The cause of the error is also indicated in the message.), (Recommended Action: Retry the image update operation and if it fails again, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BLWM-4-TIMED_FLUSH_FAILED ### Response: (Severity: 4), (Category: OS), (Description: A BLWM-enabled client failed to flush the batched LWM requests. This is most likely because the server process restarted. Wait for client to reestablish connection with server and flush the batched requests again.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_MGR-6-CERRNO_FAILED ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The SVI Adjacency Manager encountered an error while registering its error messages. Some error messages may be displayed numerically rather than with full messages. No other problems will be caused by this failure.), (Recommended Action: No action need be taken.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-RD_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: A software error has occurred whilst trying to initialize a route distinguisher node inside BGP Table database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-5-PEC_INSERTED ### Response: (Severity: 5), (Category: PLATFORM), (Description: The inserted expansion card with serial number.), (Recommended Action: None, informational purpose only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EDRM_DLL-3-RDM_SHADOW_ERROR ### Response: (Severity: 3), (Category: L2), (Description: For the region, resource data manager shadow memory operation failed due to the reason indicated. The operation parameters are as shown.), (Recommended Action: If the operation is shadow 'allocation', run show rdm server summary location <> to see whether the number of free shadow pages left is enough to meet the needed. If there are not enough free pages left, see whether the router has reached its scale limt.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-1-ERR_HW_SBE_THRESHOLD_RMA_PLIM ### Response: (Severity: 1), (Category: L2), (Description: A hardware error is detected on the PLIM, and the error threshold has been crossed. Software will take action as described in the error message, if not none, to try to contain or recover from the error. The hardware error and the software recovery action will not impact traffic. Device: %s%s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Threshold of %s - the defined threshold for this error. Count: %d - SBE error count Software action: %s - the action that software will take to try to contain or recover from the error. Recommended user action: %s - recommended action to the user. Possible values: 'none' 'replace CFP' 'PLEASE MANUAULLY RELOAD THE LC AT NEXT MAINTENANCE WINDOW'), (Recommended Action: Take the recommended user action as it is described in the error message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-2-OPTICS_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The G.709 feature is configured without the necessary license.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different levels of the MPLS VPN CSC feature? ### Response: The different levels of the MPLS VPN CSC feature are\n- CSC-1: Customer carrier uses IP to transport MPLS VPN services\n- CSC-2: Customer carrier uses MPLS to transport MPLS VPN services, but does not use labels (IP+BGP)\n- CSC-3: Customer carrier uses MPLS to transport MPLS VPN services, and uses labels (MPLS+LDP)\n- CSC-4: Customer carrier uses MPLS to transport MPLS VPN services, and uses labels with BGP label distribution (MPLS+BGP labels)\n- CSC-5: Customer carrier uses MPLS VPN to transport MPLS VPN services (MPLS VPN+LDP+BGP labels)\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LNS_EA-4-ERR_EVC_ERROR ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: After detecting an error with the IMP connection, LNS EA failed to reset that connection. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-NOT_VSA ### Response: (Severity: 3), (Category: SECURITY), (Description: Encountered a non VSA attribute.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_HEAP-7-BAD_HEAPIDX ### Response: (Severity: 7), (Category: HA), (Description: Internally heap pointers are kept as offset indices. A given heap index was found to be outside the heap.), (Recommended Action: Collect the 'show cdm trace jid all' output logs and contact TAC, if error persists.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-CHKPT_MEM_RESTORE_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Shelfmgr API call to update the HB Monitor database failed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-3-READ ### Response: (Severity: 3), (Category: MGBL), (Description: The process has illegally read configuration files before configuration manager has applied configuration. This configuration read by this process might be inaccurate after configuration manager completes applying the configuration.), (Recommended Action: Provide traceback details for further analysis. The process emitting this error message may need to be restarted after the node has completely rebooted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZENJF-4-BACKUP_ZENJF_PROM ### Response: (Severity: 4), (Category: PLATFORM), (Description: The system is booted from backup Zen-JF FPGA prom.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: action-3-BISTATE_MSG ### Response: (Severity: 3), (Category: OS), (Description: This is a test message for action->bistate message), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel mesh affinity feature? ### Response: The MPLS TE auto-tunnel mesh affinity feature allows auto-tunnel mesh tunnels to select or avoid links for the mesh paths based on configured affinity attributes. This provides more control over the mesh path selection compared to the default behavior of using the TE metric. Affinities allow mesh paths to be optimized for specific requirements. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDSUTILS-7-INTERNAL_ERROR ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_EDM-3-SYSDB_BAG_ENCODE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The data requested could not be encoded.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-6-REFBW_CHG ### Response: (Severity: 6), (Category: ROUTING), (Description: Informational message reminding the user that reference bandwidth should be consistent across all routers in the area.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-4-GRUB_WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: GRUB running on the indicated card is reporting a warning condition.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-APS_EVENT_PROCESS ### Response: (Severity: 3), (Category: OS), (Description: APS EVENT PROCESS. It is applicable for Debugging of APS SM EVENTs for APS.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-6-DEACTIVATE_ABORTED ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Package deactivate requested on this satellite has been aborted, as requested by the user. Run 'show nv satellite status' for more information about the current state of the satellite.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-CPT_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: PHY controller driver detected a parity error.), (Recommended Action: Please correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-LOCKING ### Response: (Severity: 7), (Category: SYSDB), (Description: The server has either failed to aquire or release a lock.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_HAL-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is just an info message in PLATFORM FIB HAL), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-EDM_INIT_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to initialize EDM.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-2-INDUCED_GSP_DOWN ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message indicates that shelfmgr was induced to send out a gsp node-down notification for the given node by the user.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-7-ERR_SYSDB_EDM_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: The Fabric driver was unable to become an external data manager (EDM) despite having a connection to SysDB. The operation will be retried. The Fabric driver and the System should continue to function as normal, with the exception that the 'show' commands for Fabric driver will not be available.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-4-CRITERIA_CONFLICT ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates that sc-reddrv has a tie in defining the redundancy role.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-2-CDR_I2C_ADDR_CHK_FAIL ### Response: (Severity: 2), (Category: FABRIC), (Description: Hardware initialization of Egress CDR failed. It may recover automatically after card reload), (Recommended Action: RMA the card if problems persists and doesn't recover after the reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BQS_LIB-6-BATCHOP_NOT_POSSIBLE ### Response: (Severity: 6), (Category: PLATFORM), (Description: Rearrangement of root rows using batch operations will not be done since the number of entries to be rearranged crosses the maximum supported using batch op. Rearrangement will be done using the normal CSR writes.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-6-ROLE_CHANGE ### Response: (Severity: 6), (Category: PLATFORM), (Description: Detected role change signal.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-3-DEV_SFP_PID_NOT_SUPPORTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: A PID not supported error was detected during SFP initialization. A PID not support error is reported when either the PID can not be read or not supported on the platform. The SFP is the pluggable optics on the line cards. SFP initialization may happen when linecard boots up, SFP OIR and line card process restart. The optics will not be enabled if a PID not supported error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the SFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_15_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-5-ADJ_DONE ### Response: (Severity: 5), (Category: IP), (Description: The connection to the identified neighbor no longer exists. Unless this outage was intentionally performed by a user, there are a number of possibilities which can cause the neighbor to stop responding or remove the connection: 1) network outage, 2) ANCP was disabled at the remote side, 3) ANCP process failure at the remote.), (Recommended Action: Test the connectivity by pinging the remote ip address. If this fails, determine what is causing the network outage. If it is successful, check the state, and configuration of ANCP client at the remote site. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONCERTO-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: PLATFORM), (Description: CONCERTO encountered a fatal memory allocation error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MGII_API-3-INFRA_FAIL ### Response: (Severity: 3), (Category: OS), (Description: An error occurred while processing an infrastructure service request. This should happen mostly due to resource exhaustion.), (Recommended Action: Do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key platforms that currently run Cisco IOS XR? ### Response: The main platforms running IOS XR are the Cisco CRS-1 and CRS-3 carrier routing systems, Cisco 12000 series routers, and Cisco ASR 9000 series aggregation services routers. IOS XR is designed for distributed, carrier-class routing platforms. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-3-INVMGR_MISS_SLICE_INFO ### Response: (Severity: 3), (Category: L2), (Description: The NPU driver received slice_oper_up but not yet received slice_info), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: T1E1_LNM-3-EVENT_STATS ### Response: (Severity: 3), (Category: L2), (Description: This log prints lnm summary statistics for a given bay when a function is called by client test code.), (Recommended Action: Copy the error message exactly as it appears and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of stub areas in OSPF? ### Response: A stub area is an OSPF area that does not accept external routes (Type 5 LSAs). Instead, the Area Border Router (ABR) generates a default route into the stub area for all external destinations. This reduces the size of the routing and topology tables within the stub area, as all external routes are replaced by a single default route. Stub areas are useful in reducing memory and processing requirements on routers in the stub area. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_MEAS-5-PM_LIVENESS_STATE_CHANGE ### Response: (Severity: 5), (Category: ROUTING), (Description: PM Liveness-detection has detected a state change.), (Recommended Action: None. This is a solicited message when performance measurement liveness detection notices a state change on Endpoint, SR Policies and logging state-change configuration in the corresponding liveness profile is enabled. It is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The error indicates that the entered command format is not proper.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all loc <>), show cef platform services resource oor common loc show cef platform services resource shm-objects common loc show cef platform services trace common all reverse loc show cef platform services trace common errors reverse Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETFLOW-7-ERR ### Response: (Severity: 7), (Category: MGBL), (Description: This is an error message in the Netflow manager to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate a resource needed by the application. In many cases these messages must not keep appearing after the temperory situation is resolved.), (Recommended Action: These error message is does not impact the functionality of NetFlow. Therefore no action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBC-1-L1 ### Response: (Severity: 1), (Category: SERVICES), (Description: Log level in sbc app is set to higher than nbb_console_unconditional_log_level. Use errmsg facilty to print error message), (Recommended Action: collect ips and pd trace) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPD-3-ASSERT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: Some essential condition to move on in the system has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-6-ENFORCE_EVAL ### Response: (Severity: 6), (Category: LICENSE), (Description: The licensed feature is enabled for evaluation.), (Recommended Action: The customer may consider to register for licenses.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-CORE_DUMP_OFF ### Response: (Severity: 6), (Category: OS), (Description: The core for the process has turned off delibrately), (Recommended Action: This is an informational message.Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_EVC_ERROR ### Response: (Severity: 4), (Category: L2), (Description: After detecting an error with the connection to the specified service, SSRP failed to reset that connection. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_SYSDB_REG_VERIFY ### Response: (Severity: 7), (Category: FABRIC), (Description: Ingressq Sysdb Registration verification error. The driver should retry by itself), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIP-4-ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the process. This resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-5-LDP_IGP_SYNC_CHKPT_LIMIT ### Response: (Severity: 5), (Category: ROUTING), (Description: LDP checkpointing has a limit for maximum number of neighbors per interface due to LDP IGP Sync feature requirements. It is not recommended to cross the limit provided by Engineering. If crossed, undesired affects can be seen and LDP IGP Sync feature may not work. This only applies to shared media interfaces.), (Recommended Action: Limit number of neighbors to the value as provided in Engineering guidelines) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-4-WARNING_SYSDB_INTEGRITY ### Response: (Severity: 4), (Category: SECURITY), (Description: Found digest mistmatch for SAM's SysDB name space, the SAM portion of SysDB had been deleted. If SAM backup files exists, this should not impact SAM's functionality; otherwise, CA root certificate and CRL will be lost), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSHELL-3-PTHREAD_MUTEX_LOCK ### Response: (Severity: 3), (Category: MGBL), (Description: A lock operation for synchronising shared resource, failed due to the mentioned error.), (Recommended Action: Collect the output of show logging and inform Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-4-VERSION ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-3-PLUGIN_INIT_FAILED ### Response: (Severity: 3), (Category: OS), (Description: The Linux Packet Classifier hit a fatal error whilst initialising the Packet Classification plugin. The SPP process will be restarted in an attempt to recover (a traffic impacting operation).), (Recommended Action: If the message is not seen again then the restart resolved the problem and no further action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-RDDR_FIFO0_FULL ### Response: (Severity: 0), (Category: PLATFORM), (Description: RxDDR 1875 to 200 FIFO 0 full.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVM-1-SIGPATCH ### Response: (Severity: 1), (Category: OS), (Description: The Event Manager signal handler should never be invoked directly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-BAD_SORT_TYPE ### Response: (Severity: 7), (Category: INSTALL), (Description: An internal datastructure could not be sorted, so the resultant list will be unsorted. This will only have a cosmetic effect.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-PERF_INFO ### Response: (Severity: 4), (Category: PLATFORM), (Description: Syslog info in np_perf.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-7-ERR_RES_PROG ### Response: (Severity: 7), (Category: FABRIC), (Description: Ingressq encountered an error during resource programming. If there are no further attempts to reprogram the device, the device behavior may be inconsistent.), (Recommended Action: The driver/client processes try to recover from this error. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMS-6-EMSD_SERVICE_START ### Response: (Severity: 6), (Category: MGBL), (Description: emsd service start), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_EXEC-6-START ### Response: (Severity: 6), (Category: L2), (Description: This is informational message indicating that the ASIC SCAN is started from CLI.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_IP_EA-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IP EA. Typically, this is an error where the software fails due to failure during forwarding feature programming. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv4 show cef ipv4 location <> show cef ipv4 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Designated Intermediate System (DIS) in IS-IS? ### Response: The Designated Intermediate System (DIS) is responsible for generating Link State PDUs (LSPs) on behalf of the pseudo-node representing the broadcast network. It is elected based on priority and MAC address. The DIS helps reduce the amount of flooding on a broadcast network. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFINDEX_PROVIDER-3-INTERFACE_INDEX_PERSISTENCE_PARTIAL_RESTORE ### Response: (Severity: 3), (Category: SNMP), (Description: An attempt to restore all interface indices from the interface index persistence file has failed.), (Recommended Action: Remove and re-generate the interface index persistence file by disabling and enabling persistence in the configuration. Network management applications should rediscover interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ACL-6-IPACCESSLOGS ### Response: (Severity: 6), (Category: ACL), (Description: A packet matching the log criteria for the given access list was detected.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-7-CAL_CHIP_PRINT_CURRENT_TIME ### Response: (Severity: 7), (Category: MGBL), (Description: Printing value of current time.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to set up a user group in Cisco IOS XR? ### Response: To set up a user group, which defines access privileges, use the 'group' command in global configuration mode. RP/0/RSP0/CPU0:router#config RP/0/RSP0/CPU0:router(config)#group group1 RP/0/RSP0/CPU0:router(config-GRP)#username user1 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_DISC-3-PLATFORM_GET_HW_BOARD_TYPE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Equating the Small Pool size to the SPP context size plus rewrite space (which totally equates to 1080) for Satori cards only as the small pool is used as a fallback pool for SPP. Here it unable to identify the board type, hence unable to define the SMALL_POOL size as per SPP requiremnets.), (Recommended Action: Copy the System Message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-4-TERMINATE ### Response: (Severity: 4), (Category: ROUTING), (Description: Error ocured while disabling mcast), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_3_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-2-FATAL_INT_CASE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Unable to handle the interrupt. Too many errors.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-6-MLACP_SYSTEM_ID_ARBITRATION ### Response: (Severity: 6), (Category: L2), (Description: Each mLACP peer specifies a system id for the ICCP group. If the system id's are different, arbitration must occur. However, if the peer that has supplied the values selected through arbitration disconnects, there will be a flap in the bundle state.), (Recommended Action: If the alarm is set, the user should ensure that all peers have the same system id for the ICCP Group.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLDP-7-INIT_FAIL ### Response: (Severity: 7), (Category: ROUTING), (Description: A fatal error occurred during initialization of MLDP subsystem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_RP-3-VPNV4_OUT_OF_SEQ_FREE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Platform independent FIB is freeing a VPNv4 leaf before any of the VPNv4 gtrie completes its re-initialization after restarting process fib_mgr. It is an internal software error. It is caused either by a sequencing error in platform indepedent FIB software or by VPNv4 gtrie re-initialization failure in platform depedent software which is reported via another error log before this log is seen.), (Recommended Action: Please collect the following info: show platform show version admin show install active show logging show process fib_mgr location show tech cef dumpcore running process fib_mgr location The 'node' is the location where this IOS message was observed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-6-IMP_ERROR_CLEARED ### Response: (Severity: 6), (Category: SERVICES), (Description: This message should only be seen after a corresponding IMP_ERROR message has been seen. It indicates that any problems with diversions should now have been resolved.), (Recommended Action: No further action should be necessary.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-4-SESSION_UNSECURED ### Response: (Severity: 4), (Category: L2), (Description: The MKA Session identified by the RxSCI, and CKN given was unable to be secured before being terminated. Possible reasons include no MACsec support on the specified interface, invalid MACsec configuration for the specified interface, the peer identified by the given RxSCI not having enough MACsec Capability, or other internal failure prior to the establishment of Rx/Tx Secure Channels and installation of Rx/Tx Secure Associations in MACsec.), (Recommended Action: If the MKA Session should have been secured, check for other MKA system logs that indicate the reason for not being secured. Check MACsec support on the interface & peer, MACsec configuration, and connectivity. `sh macsec mka trace errors ` and `sh macsec mka trace events` may help to diagnose the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-CPSS_OS_SERVICE_BIND_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: An attempt to bind to Marvell CPSS OS services failed. This is a fatal fault since ESD would not be able to proceed with chip initialization. ESD process will restart after this fatal error.), (Recommended Action: If this problem does not recur, no intervention is required. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-2-NODE_REBOOT_RECEIVED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Remote node notified shelfmgr about its software reboot with the reboot reason and cause code.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR-7-ERR_HEARTBEAT_FAILURE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server heartbeat monitoring mechanism detected interruption in the periodic 'Hello' messages.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-3-DEV_SFP_COMPLIANCE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A compliance error was detected during SFP initialization. A compliance error is due to unsupported optics, checksum error, EEPROM CRC error, vendor data error, or decryption error. The SFP is the pluggable optics on the line cards. SFP initialization may happen when linecard boots up, SFP OIR and line card process restart. The optics will not be enabled if an SFP compliance error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the SFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_400G_POD-3-TX_CH_LO_BIAS_CURRENT ### Response: (Severity: 3), (Category: FABRIC), (Description: The Tx POD detects a low bias current on a channel. The channel might not be functioning properly, and can cause cell drops, or corruption in the downstream.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-MISS_EOP_1_XAUI_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Missing EOP-1 from XAUI on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-SYSDB_UNBIND ### Response: (Severity: 7), (Category: INSTALL), (Description: The connection to the system database failed to shut down. This will not have any adverse effect on the running of the box.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGV6_SERVICES-3-DEBUG_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The message indicates, the supplied ltrace pathname is not a valid one. This error should not impact any major functionality. The message will indicate the cause of the error.), (Recommended Action: Please provide the logs of the following commands: Copy the error message exactly as it appears on the console or in the system log. Issue the cmd command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the cmd output, call your Cisco technical support representative and provide the representative with the gathered information. 'show cgv6 services trace info' 'show cgv6 services trace error') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-0-ECC_ERROR_FATAL ### Response: (Severity: 0), (Category: PLATFORM), (Description: Unrecoverable ECC), (Recommended Action: The board would get reloaded. On reload of board, run following commands from RSP ksh to decode PCDS information - pcds_decode -c NIANTIC <.pcds file>. If users has auto reset option disabled in admin config, then the board would not get reloaded on its own. At this stage collect the output of (admin)'show tech-support control-ethernet location file outputFile') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BPE-3-ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in BPE Driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: Please attempt to correct the error by restarting the process by issuing the command in exec mode -process restart bpe If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_13_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_13 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-4-LIB_REV_NUM_WRAP ### Response: (Severity: 4), (Category: ROUTING), (Description: The Label Information Base revision number used to manage advertisement of labels to LDP peers overflowed. This will result in faulty label distribution to LDP peers. The system recovers by toggling dynamic label switching off and on, which forces the revision number to be re-initialized.), (Recommended Action: None required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-TABLE_DUPE ### Response: (Severity: 3), (Category: OS), (Description: Query returned multiple objects.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERG-5-ROLE_MASTER ### Response: (Severity: 5), (Category: INFRA), (Description: The SERG role from the concerned group has change to MASTER from either SLAVE or uninitialized role. This is a normal redundancy event.), (Recommended Action: None required if there has been any network event or administrative action that caused this redundancy role change. Session status may be checked on the master and slave routers to verify consistency, if desired.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-PRF_CFG_IGNORED ### Response: (Severity: 4), (Category: L2), (Description: PTP has not applied an item of profile configuration on this interface because the interface does not support it.), (Recommended Action: Modify the profile configuration such that it contains only supported config. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-REMOVE_VIRT_INST_ENTRY ### Response: (Severity: 3), (Category: OS), (Description: Removing the named virtual service from the virtual service DB tracked by Virt-manager failed.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMGR-7-SYSCALL ### Response: (Severity: 7), (Category: OS), (Description: A system call failed. The calling function, the failed call, and error are displayed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_SSL-4-WARNING ### Response: (Severity: 4), (Category: SECURITY), (Description: SSL general warning message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-4-MESSAGE_NOT_PROCESSED ### Response: (Severity: 4), (Category: SECURITY), (Description: Trying to initiate a tunnel while ike is disabled. The request message for establishing the tunnel is not processed and dropped.), (Recommended Action: 'Enable ike by configuring crypto isakmp command') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-CONFIG_DEL ### Response: (Severity: 3), (Category: ROUTING), (Description: A speaker or the bRIB failed to process the removal of some configuration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RFMIB-3-VERIFICATION_FAILED ### Response: (Severity: 3), (Category: SNMP), (Description: While registering a verifier for sysdb MIB configurations of the RFMIB, failure occured. If not corrected, RFMIB might provide partial data upon query.), (Recommended Action: Restart mibd_entity process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-LINK_DELETE_FAILURE_PATH ### Response: (Severity: 3), (Category: OS), (Description: An entry could not be deleted from the links database. The full error message should indicate where the failure occured and why.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the BGP AS path attribute? ### Response: The AS path is a well-known mandatory attribute that contains a list of the autonomous system numbers that the route has traversed. Routes with a shorter AS path are preferred. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-GWARRAY_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: There was an error while initializing the local label database of the BGP process at the time of process startup. This can cause the per-CE label for some nets to change at the time of a BGP process restart or after a failover without NSR.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSCMEDIA-3-TRANSPORT_STATS_LTRACE_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicated DSC fails to initialize the ltrace of Statistics for transport media. ltrace will help basically for debugging purpose. DSC will retry to initialize the ltrace multiple times before it quits), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_MA-5-L2_OVHD_MOD ### Response: (Severity: 5), (Category: QOS), (Description: Modification of L2 overhead value will not take effect for existing subscribers with QoS policies. For the new value to take effect, remove and reapply the QoS policy.), (Recommended Action: Remove and reapply the QoS policy.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the inheritance hierarchy in IOS XR BGP configuration? ### Response: The inheritance hierarchy from most general to most specific is: session-group, neighbor-group, neighbor, af-group, neighbor address-family. Configuration at a more specific level overrides the inherited configuration from a more general level. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_RP-4-HW_MAC_INCONSIST_CFG ### Response: (Severity: 4), (Category: PLATFORM), (Description: VPLS HW MAC is enabled but Metro resource is configured in BD.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMC-7-TRANS ### Response: (Severity: 7), (Category: SYSDB), (Description: A client attempted to use an unsupported distributed transaction.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_DIAG-3-ERR_CE_SWITCH_DBG_SCRIPT ### Response: (Severity: 3), (Category: DIAG), (Description: The execution of the daignostic reset debug log collection script has failed, and the error code is indicated in the error message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-4-EXITING ### Response: (Severity: 4), (Category: INFRA), (Description: The process failed to process incoming events, and will exit. It should be restarted by System Manager and resynchronize its internal state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-OPERATION_FAILURE_WITH_ERR_STR ### Response: (Severity: 3), (Category: INFRA), (Description: Specified install operation in the error message failed. This will display the error string), (Recommended Action: The reason for this install operation failure has to be analyzed. Check the install operation log by 'show install log ' id is same as displayed in the syslog message which will be helpful to understand the reason for the install operation failure. Collect the show tech logs by running 'show tech-support install' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_METRO-4-HW_INIT ### Response: (Severity: 4), (Category: PLATFORM), (Description: Failed to initialize the Platform LC Hardware in L2FIB component.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-6-FILE_OPEN ### Response: (Severity: 6), (Category: ROUTING), (Description: The MRIB failed while trying to access a file), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_ACL-7-INIT ### Response: (Severity: 7), (Category: ACL), (Description: The ACL manager process encountered the specified error while initializing the specified facility. If this error occurs, the sysmgr process will restart the ACL manager process. This failure will occur only on RP.), (Recommended Action: Please get the information specified under the component required_info and call your Cisco technical support representative and provide the the gathered information with this error message text. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-2-VIDMON_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The VidMon feature is configured without the necessary license.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_CONF_PRX-6-INFO_GENERAL ### Response: (Severity: 6), (Category: SECURITY), (Description: The sshd encountered some problem in genric nature or plain information.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LOW_VOLTAGE_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP voltage less than or equal to the low voltage alarm threshold. The CFP is the pluggable optics on the line cards. The voltage threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check the 'show environment voltages'. If the system voltage is normal then replace the optics with working one (if any). If the system voltage is not normal, then make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_OC3_OC12-6-OPTICS_OIR ### Response: (Severity: 6), (Category: L2), (Description: Optics module has inserted %s - message related to the SFP insertion event), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAN-7-OPERATION_TRACE ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message gave a trace message. This is not a failure.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBMIRROR-3-ERR_THREAD_SIGNAL ### Response: (Severity: 3), (Category: MGBL), (Description: 'Failed to write to thread pipe in order to signal the thread for this mirror dir.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-0-PERMANENT_ONBOARD_LINK_DOWN ### Response: (Severity: 0), (Category: PLATFORM), (Description: This alarm is raised indicating a local onboard fabric link is permanently down on the card. Software will reload the card to recover from this situation. recommended_action: If this alarm is seen across multiple reloads then please contact Cisco TAC support asap as the card possibly has a permanent hardware fault. *RECUR*), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_1_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_1 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-DATASTORE_PROBLEM ### Response: (Severity: 4), (Category: LICENSE), (Description: The license manager encountered a problem attempting to adjust licenses in the given datastore. Check the error string to determine what has happened.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-MSG_CHANNEL_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cctl_primary_server process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show cctl_primary_server location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_L2FIB-2-ELAN_MACTABLE_CLEAR_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Failed to clear the elan mac-table in L2FIB PD component.), (Recommended Action: Please unconfigure and reconfigure L2VPN to recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ANCP-4-MEM_THROTTLE_EVENT_UNKNOWN ### Response: (Severity: 4), (Category: IP), (Description: ANCP process has received an unexpected event, when expecting a memory usage event. Check memory usage for this process. This could occur because of an software error in the ANCP module or the Memory handler module itself, which could in turn have been caused because of memory shortage.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-7-SYSDB_ERR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Sysdb api call failed %s - indicates the reason of the failure. reason: %s - is the decoded error reason.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-EVENT_MANAGER_DESTORY_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: 'Unable to destroy event manager on exec exit'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-2-EPM_SWITCH_LINK_FAULT_FATAL ### Response: (Severity: 2), (Category: PLATFORM), (Description: one of critical link of EPM switch is down), (Recommended Action: The board will be reloaded. Switchover would occur if standby RP/RSP is NSR ready. At this stage please collect the output of (admin)'show tech support control ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKEND-7-INVALIDARG_PATH ### Response: (Severity: 7), (Category: SYSDB), (Description: Invalid arguments were supplied to a backend function), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PA_FF-3-EVM_CREATE ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when creating Event Manager.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_DIAG-3-CE_SWITCH_DBG_SCRIPT_FAILED ### Response: (Severity: 3), (Category: DIAG), (Description: A problem was encountered while trying to spawn a script. This may be a problem with lack of resources.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-4-FIB_CONNECTION ### Response: (Severity: 4), (Category: FORWARDING), (Description: This message indicates that an error has occurred when initializing FIB event connection. Particular failure reason is included in the message.), (Recommended Action: This error occurs during process initialization. Please try restarting IP Tunnel Execution Agent process with the command process restart ip_tunnel_ea location If the problem persists, contact Cisco TAC and provide this message text as well as the information specified in required_info section.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-3-EVM_PROC_AVAILABLE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The system manager did not accept the proccess available that the rpl multi-version coordinator tried to post. The coordinator will exit so the system manager can restart it. Route policy may not be operational until this is resolved.), (Recommended Action: This error message may be transient. Restart policy_repository and try the use case again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_FIA_DRV_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: Fia Driver initialization failed), (Recommended Action: Restart the process using the CLI in exec mode - process restart fiarsp If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-IN_BUF_CRC_ERROR_LNK1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected excessive input buffer CRC error on link 1), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. Also, check for any damage to the card and its backplane connectors. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDEVINFO-3-REGISTER_ERROR ### Response: (Severity: 3), (Category: MEDIA), (Description: Failed to register Error description DLL.), (Recommended Action: restart process 'fs_dev_info' from exec prompt - from exec prompt 'restart process fs_dev_info' if issue persists contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-3-LTRACE_INIT ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Netio ltrace facility failed to initlize one of the trace buffers. The Netio trace information will not be available.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMS-7-SEND_RESPONSE ### Response: (Severity: 7), (Category: SYSDB), (Description: The SysDB server failed to send a message to the SysDB Medusa Client), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-SRGB_ALLOCATION_FAILED ### Response: (Severity: 4), (Category: ROUTING), (Description: During process startup ISIS was not able to allocate the SRGB, probably because there are already labels allocated from within the SRGB label range.), (Recommended Action: Verify that the SRGB range is free. If it is not modify the 'mpls label range' configuration to reserve space for the SRGB and reload the router.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-6-ERR_ACCT_ID ### Response: (Severity: 6), (Category: SECURITY), (Description: Accounting task id is probably larger than 2^24 - 1), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-SAVED_PARTIAL_RESET_DEBUGS ### Response: (Severity: 4), (Category: PLATFORM), (Description: Reset debug information was not fully collected, any information that was able to be collected before script was aborted are saved in the indicated file.), (Recommended Action: If this error persists, please collect the file shown in the message and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_TCAM_ODS_WRITE_WITH_FMT ### Response: (Severity: 3), (Category: OS), (Description: TCAM ods write with fmt error.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-5-FAST_RESET ### Response: (Severity: 5), (Category: PLATFORM), (Description: The NP has recovered from a diagnostic error and is now back to normal operation.), (Recommended Action: No action is required if the NP has successfully recovered.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SD-3-SYSMGR_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: The Service Director attempted to notify SysMgr that it was exiting and SysMgr returned an error. If this coincides with an attempt to configure the locations of a service, then further error may be observed from SysDB.), (Recommended Action: Restart the Service Director process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INVMGR-3-ERR_SENSOR_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates a failure in creating the sensor object for the specified slot and sensor. The sensor entry is not added to the inventory.), (Recommended Action: Issue may be due to lack of memory in the system. If memory shortage is the cause, reduce other system activity to ease memory demands and restart process invmgr via CLI 'process restart invmgr' to recover. If conditions warrant and minimum memory requirements not met, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_SSRP ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error communicating with SSRP. The error message describes what operation has failed and why it failed. The most likely reason for this is a temporary connection problem with the SSRP, but the error could also be caused by low memory resource or programming error.), (Recommended Action: In many cases, PPP MA will recover by itself. If it does not then restarting the process may help. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEA_DLL-3-MSTATS_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Feature EA DLL encountered error on initializing interface with hardware statistics API. Process will be restarted automatically. On restart, Feature EA DLL will initialize interface with hardware statistics API and no action needs to be taken.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-3-SPABRG_INIT ### Response: (Severity: 3), (Category: L2), (Description: SPAQFP Bridge has encounted an error during initialization), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSCMEDIA-3-CCTL_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: DSC could not read back plane EEPROM. This might affect the booting up of the standby. If the standby does not boot then the work around is to set the rack number to backplane eeprom association using the following cli. (admin-config)#dsc serial rack ), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-ISO_INSTALL_NO_RESET ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ETHER-2-RX_RF ### Response: (Severity: 2), (Category: L2), (Description: The PLIM received a Remote Fault on the given interface which will result in a link down. Please check the name of interface in error description. The traffic may start getting dropped after this error message.), (Recommended Action: Correct the far end interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LICENSE-3-OPERATION_FAILED ### Response: (Severity: 3), (Category: LICENSE), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure. The process can continue functioning as expected despite the failure.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE_ERR_0_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE_ERR_0 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-3-ERR_LTRACE_INIT ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error. ltrace init failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-7-SVR_REG ### Response: (Severity: 7), (Category: HA), (Description: An internal error was detected when trying to register with WDSysMon server with an initialization message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install verify packages command in IOS XR? ### Response: The 'install verify packages' command is used to verify the consistency and integrity of the currently active software packages on the router. It checks for any missing or corrupted files and reports any issues found. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-MAX_CONN_RETRY ### Response: (Severity: 3), (Category: ROUTING), (Description: Reached the maximum number of retries to connect to server using event conn), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_0_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-TABLE_INSERT ### Response: (Severity: 3), (Category: OS), (Description: Unable to delete object from table.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-HW_MODULE_POWER_PROFILE_MODE_NOT_SUPPORTED ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. Specific mode of NPU Power profile is not supported by some LC/FC. User configured this mode for a LC or RP (for FC cards), default mode will be effective.), (Recommended Action: Remove the configuration for that LC/RP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-CPP_PKT_TOO_SHORT ### Response: (Severity: 2), (Category: PLATFORM), (Description: IBS from CPP packet too short error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET-3-MIB_INIT_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An error occured while trying to initialize the etherlikemib DLL with the SNMP infrastructure. The error may result in the inability to retrieve data from the ETHERLIKE-MIB.), (Recommended Action: Such errors are not expected, and probably indicate an an inconsistency in the system state or loaded IF-MIB and ETHERLIKE-MIB DLLs. Determine if there is an initialization issue with the IF-MIB as well. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-2-ASIC_ERROR_HARD_RESET ### Response: (Severity: 2), (Category: PLATFORM), (Description: An ASIC error has occured and hard reset is needed.), (Recommended Action: An error has happened and HARD reset has been performed to recover. Collect required information and contact TAC *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-4-PEER_REACHABILITY_FAILURE ### Response: (Severity: 4), (Category: L2), (Description: ICCP-SM has detected a failure with the peer node and has attempted to failover.), (Recommended Action: Use the show l2vpn iccp-sm group group-num and the show iccp group group-num commands to determine the cause of the peer node failure. Correct the failure for the given interface and the ICCP-SM fault will clear.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-HA ### Response: (Severity: 3), (Category: ROUTING), (Description: error while doing an HA operation (e.g. starting frequent restart monitor)), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-PROBE_THREAD_CREATE_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPCD-3-ERR_INIT ### Response: (Severity: 3), (Category: IP), (Description: A failure occurred during the initialization of the process. This may have resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE flooding threshold up/down feature? ### Response: The MPLS TE flooding threshold up/down feature allows the control of when link bandwidth changes are flooded as a result of bandwidth increases or decreases. Flooding can be triggered when the bandwidth crosses user-defined up or down thresholds specified as a percentage of the link capacity. This reduces the frequency of TE flooding due to bandwidth changes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-INVALID_64K_INPUT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The 64k composite clock signal has been invalidated possibly due to loss-of-signal condition or AMI violations.), (Recommended Action: 1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 64kHz + 8kHz Japanese timing signal(defined in G.703 Appendix II.1) is applied at input port.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-GET_RENDEZVOUS ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: msg_chan_get_rendezvous failed.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-SATELLITE_INTF_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An error has occurred on the satellite.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROL_DRIVER_RSP4-3-FPGA_PROG_DONE_NOT_RECEIVED ### Response: (Severity: 3), (Category: DRIVER), (Description: FPGA PROG DONE not received 1. After Power Enable 2. After Power reset), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-RX_HDR_CSM_ERR_FIA10 ### Response: (Severity: 3), (Category: PLATFORM), (Description: FIA10 packet header checksum error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-3-IMP_ERROR ### Response: (Severity: 3), (Category: SERVICES), (Description: Whilst attempting to implement one or more attachments, the service diversion infrastructure has hit one or more problems that were not solved by a retry, and as such one or more diversions may be in an inconsistent state. Retries will continue to be made, and a further message will be printed if this situation clears.), (Recommended Action: Running 'show firewall attachments' will provide information on which attachments are suffering from errors, and in which way they will not be operating correctly. These problems may be cleared by removing and re-attaching the service to the specified interface. If this does not resolve the problem, then support should be contacted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-INTF_STATUS_ERROR ### Response: (Severity: 4), (Category: L2), (Description: *SUPPORT*), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-3-SYSDB_REG_VERIFY_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The policy_repository process failed to register for verification of changes on the displayed database path.), (Recommended Action: The policy_repository process must be restarted before it can function correctly. If the message appears again, copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-NRS_CREATE_CLASS ### Response: (Severity: 7), (Category: OS), (Description: RDS library uses NRS API to create nrs classes . nrs_create_class API failed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_CONFIG-7-ERR_SYSDB_REG_VERIFY ### Response: (Severity: 7), (Category: OS), (Description: Sysdb verifier registration failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_8 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port 8.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port 8 interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SYNC-7-EXTERNAL_API_ERROR ### Response: (Severity: 7), (Category: OS), (Description: Common external API returned an error), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_EDM-3-DATALIST_ADD_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The attempt to add an item to an external data manager datalist has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_VCM-3-MAIN_IF ### Response: (Severity: 3), (Category: L2), (Description: Unexpected error on the main interface), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL-3-UNKNOWN_MSG ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An unexpected message was received by this process. This is relatively a harmless error and should not have any immediate impact on the operation of tunnel interfaces. It must still be reported and looked into.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLARP_LITE-3-ERR_SHMEM_UNAVAILABLE ### Response: (Severity: 3), (Category: L2), (Description: cHDLC MA has requested transfer of more interface records than shared memory can accommodate), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-UNSUPPORTED_IP_LENGTH ### Response: (Severity: 3), (Category: L2), (Description: EVPN received an IMET route with unsupported IP address length.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CRYPTOMAP-2-PARSE_ERROR ### Response: (Severity: 2), (Category: OS), (Description: An error occured parsing show output data), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-6-HEARTBEAT_ALERT ### Response: (Severity: 6), (Category: PLATFORM), (Description: Periodic sanity heartbeat messages from the line card have not been received. This is just an alert. If the problem continues a heartbeat failure message will be generated and the shelfmgr will attempt recovery by resetting the affected card or automatically attempting an RSP failover if needed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-PROC_RPC_OPERATION_JID ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-ERR_THREAD_FN ### Response: (Severity: 3), (Category: SECURITY), (Description: The call to pthread functions, such as pthread_create, lock/unlock a mutex or wait on a condition, failed. The error is displayed in the message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-6-ASIC_DISCOVERY_IS_PENDING ### Response: (Severity: 6), (Category: FABRIC), (Description: 1. Driver periodically (every 30 secs) checks for the NPU devices to be discovered. When devices are not discovered this message is logged. If there is a delay in powering up the devices, a couple of messages may be expected.), (Recommended Action: If the messages are logged continuously, then either the devices are not powered UP and seen on the PCIe bus or the driver is not aware of the ASICs coming UP. Need to reload the board for recovery. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBCSVI_EA-3-STATE_CHANGE ### Response: (Severity: 3), (Category: SERVICES), (Description: While the SBCSVI EA process was checking the state for the specified interface pair, an error was encountered. The interface pair in question may be left in an inconsistent state.), (Recommended Action: It may help to restart the SBCSVI EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: Zl30160_ERROR-3-ERR_FTRUNCATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in ClkCtrl driver due to ftruncate function call failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_HFR-7-ERR_HEARTBEAT_FAILURE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server heartbeat monitoring mechanism detected interruption in the periodic 'Hello' messages.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_SYSLOG_PRX-3-ERR_GENERAL ### Response: (Severity: 3), (Category: SECURITY), (Description: SSH encounterd some error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_SHUTDOWN_LINK_FABRIC ### Response: (Severity: 1), (Category: PLATFORM), (Description: An ASIC error has occured and cause fabric link shutdown.), (Recommended Action: An error that causes fabric link shutdown has happened and been handled Collect required information and contact TAC *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-6-DEFAULT_POLICY_ACCEPTED ### Response: (Severity: 6), (Category: SECURITY), (Description: The default policy is being used because the local configured policies did not match with the peer's policies.), (Recommended Action: 'Check if this is indeed the desired ISAKMP policy to use. To avoid using the default policy, reconfigure the local policy to match with peer's policy') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARB-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Arbiter driver encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SEG_DATA_FIFO_OFLOW_0_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress seg data fifo overflow on xaui-0 bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_0_TS_CORE_ERR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: NPU-0 timestamp core error on bridge instance-1.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-ACP_VRF_GLOBAL_REMOVE ### Response: (Severity: 6), (Category: SERVICES), (Description: 'Autonomic network VRF has been removed globally'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ET1_INTR_SOP_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ET1_INTR_SOP_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-5-UPDATE_INTERRUPT ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: Control session to satellite disconnected while image update was in progress. Run 'show nv satellite protocol control' for more information.), (Recommended Action: Re-try the update once the session has reconnected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_OFF ### Response: (Severity: 6), (Category: L2), (Description: The SSM Off condition applies to references used for timing the node. It occurs when the SSM for the reference has been turned off. The ONS system is set up to receive SSM, but the timing source is not delivering SSM messages.), (Recommended Action: Clear the SSM Off Condition) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-RX_HDR_CSM_ERR_FIA01 ### Response: (Severity: 3), (Category: PLATFORM), (Description: FIA01 packet header checksum error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SSP_INTR_SP1_RX_NEOP_ERR_P_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SSP_INTR_SP1_RX_NEOP_ERR_P interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-RESET_MASK_BULK ### Response: (Severity: 4), (Category: DRIVER), (Description: In order to perform the CCC reset for FC card, will have to unmask the buffer offset in backplane FPGA. Additional debug info On reload rack num command execution, ctrace logging will not available.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERG-4-ASSERT ### Response: (Severity: 4), (Category: INFRA), (Description: The SERG process hits some abnormal condition. These warnings will not affect functionality of SERG.), (Recommended Action: Collect the traceback associated with this Log and contact the engineer.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What scheduling algorithms are used by the IOS XR microkernel? ### Response: The IOS XR microkernel supports three scheduling algorithms\n1. FIFO scheduling: Thread runs until it relinquishes control or is preempted. Used for kernel idle thread.\n2. Round-robin scheduling: Limits run time of a thread to a timeslice. Used for most processes.\n3. Sporadic scheduling: Thread runs at normal priority for a set budget time before dropping to low priority. Prevents starvation.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP allowas-in feature? ### Response: The BGP allowas-in feature disables the default BGP loop prevention mechanism of rejecting prefixes that contain the local AS number in the AS path. It allows a specified number of occurrences of the local AS number to be present in the AS path of received prefixes. It is configured with the neighbor allowas-in command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an access list in IOS XR? ### Response: To configure an access list, use the 'ipv4 access-list' command followed by the access list name and rules. RP/0/RSP0/CPU0:router(config)#ipv4 access-list ACL1 RP/0/RSP0/CPU0:router(config-acl)#permit tcp any any eq www <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMS-3-ASYNC_MSG_TAG_INVALID ### Response: (Severity: 3), (Category: SYSDB), (Description: An internal error left the msg tag to be an invalid one. Causing the request to be timed-out.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OCIFIP_V4MA-3-INTERNAL_ERR ### Response: (Severity: 3), (Category: IP), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_EA-3-INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: An unexpected initialization error has occurred in the IPv6 EA component. Please collect the necessary traces and contact the TAC representative.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-RIB_ERR_PROTO_MODIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred on a request to modify the purge time in RIB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-RSI ### Response: (Severity: 3), (Category: ROUTING), (Description: A call to an external event manager function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-XBAR_TIMEOUT_ERROR_LNK4 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected an crossbar timeout error on link 4), (Recommended Action: This alarm is transient and should auto-clear when error condition is resolved. If the alarm doesn't clear, then please reload the card using command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE7_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE7_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-6-MBR_BFD_STARTING ### Response: (Severity: 6), (Category: L2), (Description: BFD sessions have been started on all the members of the given bundle. If the BFD session has not gone UP by the time specified in the message, the BFD session on the member of the bundle will be marked as DOWN, which may impact traffic.), (Recommended Action: Ensure that the bundle and its members are configured correctly on the neighboring router, and that all the interfaces are up. Ensure that BFD is configured on the member interfaces on the neighboring router.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-2-ENFORCE_GRACE_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature is still enabled after grace period.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-6-NO_TEST ### Response: (Severity: 6), (Category: DIAG), (Description: The diagnostic test cannot find tests to run.), (Recommended Action: In some cases on some platforms, a Field Diagnostic image needs to be loaded onto the line card if you want to run the test. If applicable, download a Field Diagnostic image onto the line card. In other cases, the test is simply not available. This message is an informational and does not require user action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_0_PKT_MINLEN_ERR_3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet minimum length error on NPU-0 interface on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-7-THREAD_CREATE_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to create threads.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you monitor BGP sessions in Cisco IOS XR? ### Response: BGP sessions in Cisco IOS XR can be monitored using the 'show bgp sessions' command. It provides information about the status of BGP sessions, including the neighbor IP address, AS number, session state, and other relevant details. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-NODE_POWEROFF_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The power off operation for the indicated node has failed.), (Recommended Action: Check if the card in the indicated node is properly inserted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-3-SR_POLICY_BSID_UNAVAIL ### Response: (Severity: 3), (Category: OS), (Description: Requested binding-SID for the SR policy could not be allocated due to some error. The most common error is that it is already assigned / allocated to other SR policy or to other app.), (Recommended Action: If reason is due to a conflict, please check the conflict and resolve accordingly. For MPLS, check 'show mpls label table label ' to find out the current owner of the label. For SRv6, check the SID-manager to find out the current owner of the local SID. If reason is an internal error, then try recovering it by restarting the xtc_agent process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFDIAGBASE-3-PAYLOAD_ERROR ### Response: (Severity: 3), (Category: DIAG), (Description: Diagnostics was unable to attach or detach the payload stored in shared memory to/from a packet in the queue. This is a serious error and should not occur. It may indicate there is a bug in the software. This is not a service impacting error.), (Recommended Action: Check the log ('show logging') to determine if there are any other related error messages. Also, please check Bug Navigator ( https://tools.cisco.com/bugsearch?referring_site=btk ) to search for any bugs in this area. If the error continues, copy the error message exactly as it appears on the screen and gather any relevant information about the circumstances. Also collect the information from the 'show logging' and 'show tech diagnostics' commands. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDEVINFO-3-NO_MEMORY ### Response: (Severity: 3), (Category: MEDIA), (Description: Not enough memory available in the system.), (Recommended Action: restart process 'fs_dev_info' from exec prompt - from exec prompt 'restart process fs_dev_info' if issue persists contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_AGG-3-STANDBY_DIS_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB aggregator failed to disconnect standby with the above reason.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_SERVER-3-I2C_READ_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An error occured while reading from I2C device. This may be a program level error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_LIB-7-DEBUG ### Response: (Severity: 7), (Category: L2), (Description: This is a debug message in the PLIM library driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.), (Recommended Action: 'show logging' to confirm sysdb errors) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FHRP_OUTPUT-2-CRIT_PKT_THREAD_SIGNAL ### Response: (Severity: 2), (Category: IP), (Description: The FHRP Output process failed to signal end of initialization to the Main thread and will leave the Main thread hung. The process will assert to recover from this condition.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSDIR-1-OPERATION_ABORT_PREV ### Response: (Severity: 1), (Category: INSTALL), (Description: Quickstart operation aborted because an error was encountered in one of the previous operations.), (Recommended Action: The reason for this qs operation failure has to be analyzed. Collect the show tech logs by running 'show tech-support qs' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMAEDM-7-BAG_REG_FAILED ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: Internal error), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDS_DB-3-GET_DATUM ### Response: (Severity: 3), (Category: OS), (Description: Failed to get the the datum for the message connection.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-SYSMGR_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM_MA-3-CONN_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Connection error with IM or PIM.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFLX_LIB_MGR-4-UNABLE_TO_RESYNC ### Response: (Severity: 4), (Category: SERVICES), (Description: The Interflex Manager process was unable to reconnect to another process in order to prompt a resync. Interflex may now be out of sync with the rest of the system until it is restarted.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UCP_LCTRL_LIB-3-ERR_LIB ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured with the line control library), (Recommended Action: Please provide the output of the line control trace to the TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFC_WATCHDOG-5-RESTORE ### Response: (Severity: 5), (Category: PLATFORM), (Description: The Priority Flow Control (PFC) watchdog condition has cleared. PFC packets are no longer being continually received and the queue is being restored to send traffic.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-PROVISION_PRE_CHECK_HOST ### Response: (Severity: 4), (Category: MEDIASVR), (Description: This ios_msg is raised when provision prechecks are performed on the disk/system), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO_COMMON-3-OUT_OF_MEMORY ### Response: (Severity: 3), (Category: L2), (Description: The system is low on memory.), (Recommended Action: This indicates a low-memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPM-3-ERROR_TOKEN_MISMATCH ### Response: (Severity: 3), (Category: SECURITY), (Description: There was a token error mismatch while the system was attempting to delete a record.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VS_CLIENT-7-INIT_SUCCESSFUL ### Response: (Severity: 7), (Category: INSTALL), (Description: Test code only - will never be seen by customers.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-2-EVENTATTACHFAIL ### Response: (Severity: 2), (Category: HA), (Description: The LR Daemon encountered an error when registering for synchronous or asynchronous events.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-INCONSISTENCY_DETECTED ### Response: (Severity: 3), (Category: OS), (Description: RCC or LCC detected an inconsistency during verification of the route/label information between RIB/LSD and the FIBs. Please collect the inconsistency data and analyze the results.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKWATCH-4-PAK_HDR_INVALID ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: An attempt has been made to fragment a packet buffer with a header length that is higher than allocated particle max size. This usually indicates the process using fragment apis might have miscalculated the header length that does not fit into a particle), (Recommended Action: Please collect a core dump of the process from which the message is output, using the 'dumpcore running' command to catch the current packet memory state ('exception pakmem on' must also be configured), the full console logs and 'show proc pidin loc ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHOW_VERSION_CMD-7-SYSDB_BIND ### Response: (Severity: 7), (Category: PLATFORM), (Description: A Version Manager CLI command was unable to bind to the system database from which it obtains information. The command will not contain all expected information.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-3-CONF_SOCKET_CREATION ### Response: (Severity: 3), (Category: MGMT), (Description: This is expected in case Configuration database is down, once it is up this error doesnt come), (Recommended Action: Wait for configuration database to come up. The issue should be recovered once configuration database comes up) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-LOOPBACK_ALREADY_ASSOCIATED ### Response: (Severity: 3), (Category: L2), (Description: Loopback is already associated with logical switch, first remove this association.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBCSVI_EA-3-SSC_SEND_SRV ### Response: (Severity: 3), (Category: SERVICES), (Description: A problem was encountered while trying to send a single message to the Service Director. The Service Director may not be up to date with the state of this services on this node, so the associated SBCSVI interfaces located on this node may fail to forward packets.), (Recommended Action: It may help to restart the SBCSVI EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-3-CHECK_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Generic failure caused by an error while processing an action.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the two main types of IS-IS subnetwork types and how do they differ in terms of adjacency formation? ### Response: The two main IS-IS subnetwork types are point-to-point and broadcast. On point-to-point subnetworks, no DIS is elected and routers send LSPs directly to neighbors. On broadcast subnetworks, a DIS is elected and LSPs are multicast to all neighbors. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_WDSYSMON_EVENT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-ERR_INFO_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This error indicates a problem with the software on programming the hardware. This typically occurs when there is a problem with the resource utilization in the card where the error is seen. Here is a list of possible reasons for this message. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Resource limitations. This condition indicates a problem where the software has limited resources to operate on.), (Recommended Action: Please collect the console log and the CLI output. show cef show memory summary show cef location <> show memory location <> show cef trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBUS-6-HBM_SAMSUNG_MEMORY_REPAIR ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message in the SBUS Driver to indicate details about a HARD memory repair that has been performed on the specified HBM memory.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_FI_INTR_RCTL1_LO_OVERRUN_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_FI_INTR_RCTL1_LO_OVERRUN interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS traffic engineering fast reroute feature? ### Response: The MPLS traffic engineering fast reroute (FRR) feature provides link and node protection for MPLS TE tunnels. It enables fast traffic recovery upon link or node failure using pre-signaled backup tunnels that bypass the protected resource. It is enabled on a per-tunnel basis with the tunnel mpls traffic-eng fast-reroute command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-4-ERR_CHKPT_DUPLICATE ### Response: (Severity: 4), (Category: L2), (Description: Whilst restoring one of its checkpoint tables MFR MA found multiple entries for the same interface. MFR MA will use the first checkpoint entry it finds for each interface and ignore any subsequent duplicates. This is caused by a programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE7_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE7_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-3-NODEID_GET_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Self nodeid can not be obtained.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_12 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-LOAD_BALANCE_LINK_UP ### Response: (Severity: 6), (Category: FABRIC), (Description: This info message indicate that there is no link down on the specified S2 ASIC due to fabric link load balancing.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-3-PULSE_FAILED ### Response: (Severity: 3), (Category: OS), (Description: SSM process sends a pulse to the monitored process over a lwm channel. This error is reported when it tries to open a connection to the channel and is stuck.), (Recommended Action: Collect system log information for the reported service and pid. For mentioned pid collect show process , follow process Collect show tech ssm. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-3-REG_UNKNOWN_TYPE ### Response: (Severity: 3), (Category: MGBL), (Description: could not find registry entry type.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-ERR_SYSDB_SET ### Response: (Severity: 3), (Category: MGBL), (Description: 'sysdb item set failed. The error is displyed in the error message.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-3-INIT_FAILURE ### Response: (Severity: 3), (Category: DRIVER), (Description: IOFPGA Driver Initialization failed. Process Manager will restart the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RAW-3-SOFTWARE_INSTALL ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the RAW process attempts to register with Install Manager for notification of software package installation and deinstallation on the system.), (Recommended Action: The process will attempt to recover from this situation by restarting or retrying. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-MASKFORMAT_REGISTER ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to register the maskformat in prefix form failed. The error is displayed in the message'), (Recommended Action: Collect show nvgen trace, show logging and send this to tech support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-OOR_GLOBAL_BSR_CRP_LIMIT ### Response: (Severity: 3), (Category: ROUTING), (Description: OOR Error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_0_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-EARLY_RESTART_ABORT ### Response: (Severity: 3), (Category: INFRA), (Description: The install orchestrator (instorchagt) was restarted very early during an install operation. No system changes were made, and the requested operation has been aborted. Please try the operation again. This operation will not appear in 'show install history'.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GRID_SVR-7-ERR_INIT ### Response: (Severity: 7), (Category: PLATFORM), (Description: Initialization of grid server process has failed due to one of the following reasons: 1) Failed to initialize GRID Server.), (Recommended Action: No action is required. Process will be restarted. If not recovered, it's a fatal condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-3-AOOPT_SEND_NOKEY ### Response: (Severity: 3), (Category: IP), (Description: There is no active send-key for the specified keychain and hence can't send data to the peer.), (Recommended Action: Check the keychain to see if it has any active keys. Sometimes, this error might come if there is no overlap between the send-keys. In that case, if keychain shows that there is an active key, then this error can be ignored. Else, change the configuration to have an active send-key.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD_inv-3-SYSDB_ITEM_ERROR ### Response: (Severity: 3), (Category: HA), (Description: SysDB returned an error to LRd.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-6-INFO ### Response: (Severity: 6), (Category: L2), (Description: This is an information message in the ASR9K platform FIB specific code software. The message is for debug purposes only and not an error.), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-6-RESET_STANDBY ### Response: (Severity: 6), (Category: PLATFORM), (Description: Issue hardware reset to peer standby RP or SC.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.=) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-6-REPLACE_DONE ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Package replace requested on this satellite has completed. Run 'show nv satellite status' for more information.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_1_XAUI_RDY_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: NPU-1 XAUI not ready on bridge instance-0.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-4-INVALID_TEST ### Response: (Severity: 4), (Category: DIAG), (Description: A test ID for diagnostics that does not exist was requested.), (Recommended Action: Ensure the specified test ID number is supported by the line card. The list of available tests and their associated test IDs can be retrieved using 'show diagnostic content'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-5-INIT_FAILED ### Response: (Severity: 5), (Category: HA), (Description: RMF server failed to initialize the specified item due to the the specified error. This failure will cause a restart of the RMF server.), (Recommended Action: If condition is reported multiple times, collect show redundancy trace location all and show logging outputs and contact customer suppport.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-5-CORE_FILE_NAME ### Response: (Severity: 5), (Category: OS), (Description: Name of the core file), (Recommended Action: Displayed when a process is crashed. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_EDM-3-DATALIST_SET_MORE_FLAG ### Response: (Severity: 3), (Category: ROUTING), (Description: A client has requested information through SysDB from OSPF. During execution of the request an attempt to set a flag indicating there is more data for the client failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-2-INVMGR_NO_VALID_NPUS_DETECTED ### Response: (Severity: 2), (Category: L2), (Description: This fault indicates a condition where inventory manager did not send any valid max slice callback to npu driver.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-ISSU_READY_STATE ### Response: (Severity: 5), (Category: ROUTING), (Description: The listed state refers to the state of ISSU, which is either 'ready', \ 'ready with NSR', or 'not ready'.), (Recommended Action: None. This is a solicited message (by \ 'logging events sync-updates' . User may verify the ISSU sync \ status as shown in the output of \ 'show mpls traffic-eng issu status detail'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-7-ERR_SYSDB_EDM_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: Ingressq Sysdb Register EDM error.The driver might lose some of its functionality.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-4-FABRIC_SHUTDOWN_BOARD ### Response: (Severity: 4), (Category: FABRIC), (Description: Unsupported board in slot for the fabric mode configured.), (Recommended Action: Check running configuration if five fabric mode is configured In this mode, it is expected certain LC board types such as LC36 will not be supported this. Remove this board or remove the configuration if it is desired to bring up this board. Additionally FC cards in slots 0,6,7 will not be brought up) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MOTHRA-6-INFO_MSG ### Response: (Severity: 6), (Category: L2), (Description: This is a Informational message in the mothra driver to indicate an operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV6-3-UPDATE_ERR ### Response: (Severity: 3), (Category: L2), (Description: Errors during improper updation of variables or incorrect return state in IPV6 FIB platform.), (Recommended Action: Please collect the required logs. Also notice if the error message is transient or persistent. If errros persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_CFG ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error encountered in RIP configuration functions.), (Recommended Action: Please retry the configuration command that caused this error and check running configuration to make sure it is correct. If the error persists open a case with TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD_INTF_EA-4-DB_ATTACH ### Response: (Severity: 4), (Category: L2), (Description: The specified process failed to connect to PIRD shared memory database on initialization.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-VIRTUAL_IN_NON_BACKBONE ### Response: (Severity: 4), (Category: ROUTING), (Description: An internal error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-INIT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occurred during initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please provide output from the following commands: - show version - show install active - show dll - show running-config - show logging - show ospfv3 - show ospfv3 trace all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO_API-3-INVALID_AIB_ENTRY ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'While deleting given AIB entry found it is invalid.' 'This will not effect the process.'), (Recommended Action: 'ISSU manager will use some alternate API' 'If the issue persists ' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-MISS_EOP_1_XAUI_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Missing EOP-1 from XAUI on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSA-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric statistics aggregator process encountered a fatal error to create its event manager for receiving events. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GT_I2C-3-UPPER_FANTRAY ### Response: (Severity: 3), (Category: PLATFORM), (Description: As shown in the message.), (Recommended Action: Physical OIR of upper fan tray required to recover from this hang.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WD_STAT_PUB-3-SHM_EDM_ERR ### Response: (Severity: 3), (Category: HA), (Description: A shared memory for statistics area might be corrupted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-2-FPGA_IMG_ERR ### Response: (Severity: 2), (Category: L2), (Description: The FPGA is running rollback image, this could be caused by previous FPD failure. %s - device name, Rx MAC or Tx MAC.), (Recommended Action: Check if the previous FPD failed. Upgrade the FPGA with FPD CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-3-UNLOCK_FAILED ### Response: (Severity: 3), (Category: IP), (Description: Internal error during unlocking of TCP resource.), (Recommended Action: Please try restarting the process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_IO-3-UNHANDLED ### Response: (Severity: 3), (Category: IP), (Description: The ipv4_io process has encountered a software error during normal operation from which it cannot recover.), (Recommended Action: The process will attempt to rectify this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise check whether the error code contained in the message indicates that there was a failure to allocate the necessary memory and take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If resource allocation was not the problem and it hasn't been fixed by a subsequent restart then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-4-INVALID_PLATFORM_EVENT_IFH ### Response: (Severity: 4), (Category: L2), (Description: The platform has triggered an event for an interface that has not been configured for Ethernet Link OAM. This indicates a bug in the software.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VLANIFMIB-4-MEMORY ### Response: (Severity: 4), (Category: SNMP), (Description: The VLAN Interface table relationship MIB was unable to allocate sufficient memory to complete an operation. It is likely that an SNMP query that was in progress will not have been completed.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEV2-6-SVC_INFO ### Response: (Severity: 6), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-CHUNK_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show processes igmp detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes igmp detail output, call your Cisco technical support representative and provide the representative with the gathered information. *SH_CMD show igmp groups) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHOWTECH-2-CRIT ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GNSS-4-LOST_EVENT ### Response: (Severity: 4), (Category: L2), (Description: The specified process failed to receive an event that was sent to it.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_FWD-2-LOGICAL_PORT ### Response: (Severity: 2), (Category: PKT_INFRA), (Description: Failed to get the logical port for the specified interface from the Platform Mgr. This will cause the interface to not get created properly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-7-ERR_SYSDB_BAG_ENCODE ### Response: (Severity: 7), (Category: FABRIC), (Description: FSDB server encountered error in sysdb bag encode operation. This could affect output of some of the fabric CLI commands.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-GETLINE_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: getline_init() failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_IR0_INTR_FC_BUF_OVFLOW_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_IR0_INTR_FC_BUF_OVFLOW interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-4-UNKTIMER ### Response: (Severity: 4), (Category: ROUTING), (Description: The type of the expired timer is unknown to EIGRP. If the unknown timer was suppose to be one among the known timers then there could be some effect depending on what the known timer was. The problem may resolve itself if the timer expires again with correct type. To name a few: 1. If the unknown timer was suppose to be \'RIB related timer\' then the effect could be that EIGRP may fail to install the prefixes in RIB. 2. If the unknown timer was suppose to be \'Event related timer\' then the effect could be that EIGRP may fail to join the multicast group on certain interfaces. 3. If the unknown timer was suppose to be \'Active timer\' then the effect could be that EIGRP may fail to send the SIAQUERY and hence fail to do the necessary cleanup for the Active route.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-QDR_DATABIT_STUCK_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: QDR memory databit stuck on bridge instance-3.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-3-BUS_UNKNOWN_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A PCI/PCIe bus error has occurred. The error type is unknown. If the device indicated in the message is the root port, the error could be reported by any device in the root port's hierachy, or could be reported by the root port itself.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_HAL-3-ERR_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This error in PLATFORM FIB HAL indicates that engine object initialisation failed for NH info IP tunnel), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show logging, show version, show platform, show install active, show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTAGENT-4-XR_PART_PREP_RESP_ERR ### Response: (Severity: 4), (Category: INFRA), (Description: SDR/XR partition preparation has failed. SDR Mgr will retry the same operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_12_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_12 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_THOR_L2FIB_VPLS-3-INIT_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize the VPLS module in the platform L2FIB VPLS component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOSHAL-6-FLOW_QOS_CONFIG ### Response: (Severity: 6), (Category: PLATFORM), (Description: 'Any change in flow qos max flow count requires the LC to be rebooted to ' 'take effect.'), (Recommended Action: hw-module location reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How are control plane packets handled differently from transit packets in Cisco IOS XR? ### Response: Control plane packets, which are destined to the router itself, go through the Local Packet Transport Service (LPTS) for classification and rate limiting before being delivered to the relevant processes. Transit packets are forwarded directly in hardware and do not go through LPTS processing. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-3-REG_PROC_FAILED ### Response: (Severity: 3), (Category: HA), (Description: Process registration for node memory state with wdsysmon is Failed.), (Recommended Action: Collect show tech watchdog and contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-3-INIT ### Response: (Severity: 3), (Category: INSTALL), (Description: An error occurred during initialization. The Install infrastructure will not be able to function.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_CHKPT_DUPLICATE ### Response: (Severity: 4), (Category: L2), (Description: Whilst restoring one of its checkpoint tables PPP MA found multiple entries for the same interface. PPP MA will use the first checkpoint entry it finds for each interface and ignore any subsequent duplicates. This is caused by a programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-3-TRACEBACK ### Response: (Severity: 3), (Category: OS), (Description: 'Observed a GSP traceback on console.'), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE-7-CTRL_BADMAGIC ### Response: (Severity: 7), (Category: OS), (Description: Internal debugging message. For subsequent analysis of magic number corruption, snapshot of running process core dump has been taken.), (Recommended Action: Informational only. Indicates magic number corrupted and has been recovered.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYNCFS2-7-LOST_SYNC ### Response: (Severity: 7), (Category: MEDIA), (Description: Syncfs failed to transfer the specified file to the standby card.), (Recommended Action: Ensure there is sufficient disk space on standby card's filesystems, and that all removeable media is correctly inserted. Once resolved, power cycle the standby card using 'hw-module slot X shut' and 'no hw-module slot X shut' to resume synchronization.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAA-7-ERR_SYSDB ### Response: (Severity: 7), (Category: SECURITY), (Description: 'Failed to execute a SysDB operation'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ND_REGISTRATION_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: ISIS was unable to register with ND to preload IPv6 mac address resolutions.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOR-4-INTERNALERR ### Response: (Severity: 4), (Category: INSTALL), (Description: An internal software error occurred.), (Recommended Action: An internal error occured before the install operation could complete. This internal error will be recovered automatically. Please retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_12_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_12 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LACP_LITE-3-ERR_LL_DLL_ASYNC_SEND_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Attempt to send pulse to LACP lite process fails), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_OUT_MEM_CORR_ECC_ERROR_LNK3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast output memory correctable ECC error on link 3), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-RSPI_PROT_GAP_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: RxSPI protocol packet gap error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CALVADOS_DUMPER-6-COPY_SUCCESS ### Response: (Severity: 6), (Category: INFRA), (Description: Dumper has copied targeted file successfully), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-3-NULL_TRANSPORT_CALLBACK ### Response: (Severity: 3), (Category: OS), (Description: Detected a NULL transport callback function.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-4-WARNING_FIPS ### Response: (Severity: 4), (Category: SECURITY), (Description: The sshd encountered a warning condition.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-DBG_ERR ### Response: (Severity: 3), (Category: L2), (Description: Some error occured while trying to initialize/register debugs. The text of the message displays the failed operation with error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-6-CRC_ERROR ### Response: (Severity: 6), (Category: PLATFORM), (Description: The message received from Canbus Controller has CRC error computed. This is indicative of a low level serial device transmission error. In most cases, the message is fully recoverable automatically.), (Recommended Action: Provide the following CLI output: (admin)# show canb trace loc (admin)# show canb server-stats loc all (admin)# show env volt Wait 5 minutes, again give CLI: (admin)# show env volt If the voltage output looks correct, then there is likely no negative impact from the CRC error. If the voltage output looks incorrect, wait 30 minutes and give the CLI command again. If the voltage output still looks incorrect, If this error occurs repetitively for a particular card, contact TAC for further evaluation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-3-SPURIOUS_NODE_DOWN ### Response: (Severity: 3), (Category: OS), (Description: GSP process receives notification that the node it's running on is down. Communication over GSP will be cutoff to/from this node.), (Recommended Action: In admin mode, show tech shelfmgr In order to recover, OIR the node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PM-4-WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: The Platform Manager encountered an provisioning warning.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect 'show log location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_DISC-3-PARTICLE_BIG_POOL_DEFINE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Define particle pools over memory regions. If there is not enough space to hold all the particles, less particles will be created. Each pool can have its own particle size. Particle defined as Big pool got failed.), (Recommended Action: Copy the System Message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Rx alignment loss on XAUI to NPU-0 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ITAL_SHM-7-ERR_INIT_DEBUG ### Response: (Severity: 7), (Category: OS), (Description: Initialization of ITAL failed. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER_SNAP-3-INSANE ### Response: (Severity: 3), (Category: OS), (Description: The process explicitly configured a threshold of how many non-invasive voluntary coredump requests should be permitted before deeming the process insane. This has been exceeded, and so the process is being restarted.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_3_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Tx power less than or equal to the low Tx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Tx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Replace the QSFP+ with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SCAN_STACK_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Core dump failed because scanning stack for the process failed.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_1_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Rx power greater than or equal to the high Rx power warning threshold. The QSFP+ is the pluggable optics on the line cards. The Rx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_EA_BW_CHG-6-BWCHG_LOG ### Response: (Severity: 6), (Category: QOS), (Description: This is an informational message from the QoS EA Process, it indicates that bandwidth change happened for an interface.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COREHELPER-6-CORE_COPIED ### Response: (Severity: 6), (Category: OS), (Description: Copied core file to specified path.), (Recommended Action: This message is information only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONCERTO-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: CONCERTO Driver encountered a fatal error and is not able to recover. The supplied text string will explain the reason. Call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_HFR-7-ERR_EVM_CREATE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while attempting to create an event manager. This failures affects the ability of the process to service various messages / pulses from other threads / processes. This facility is deemed crucial and the process automatically restarts on this failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-6-INFO_MAC_IWF_IF_SES_LMT_NO_REACH ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: The number of IWF PPPoE sessions from a particular MAC address on the given access interface is no longer exceeding the configured maximum.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-2-CBC_BROWNOUT_RESET ### Response: (Severity: 2), (Category: PLATFORM), (Description: Brownout condition for the specified node has been detected by CBC. Shelfmgr is resetting the node to see if it can come up in subsequent attempts.), (Recommended Action: Ensure that the system has enough power. Check the power source for the chassis is working correctly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_MGR-3-ACTIVATE ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the activation of the Service Virtual Interface infrastructure. Activation occurs when the card transitions to ACTIVE state. This error resulted in the restart of the process.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'redistribute' command in OSPF? ### Response: The 'redistribute' command is used to inject routes learned from other routing protocols, static routes, or connected routes into the OSPF routing domain. This is commonly used at the edge of an OSPF domain to import external routes. The redistributed routes are advertised as external LSAs (Type 5 or 7) by the Autonomous System Border Router (ASBR). <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-XFP_LNK_FAULT_ERROR_5 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the XFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. Do XFP OIR. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRv6-4-BLOCK_OOR_GREEN ### Response: (Severity: 4), (Category: ROUTING), (Description: The SRv6 SID manager database is no longer in a Out of Resource or Warning state. Normal local SID allocation operations have resumed. Details about the limit can be seen with show segment-routing srv6 manager command. Details about the block can be seen with show segment-routing srv6 block. The list of local SIDs can be seen in show segment-routing srv6 micro-segment local-sid), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CVAC-3-FILE_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: An error was encountered when CVAC (Cisco Virtual Appliance Configuration) was trying to perform the specified operation on the specified file.), (Recommended Action: If possible, identify the reason for the error and make appropriate changes to fix the error. You may then reinsert the media containing this file and issue the 'reload' command to cause CVAC to run again after the router reloads.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_TF_INTR_FIFO_1LO_OVFL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_TF_INTR_FIFO_1LO_OVFL interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIP-4-DB_ATTACH ### Response: (Severity: 4), (Category: L2), (Description: The specified process failed to connect to PIRD shared memory database on initialization.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-7-PROC_READY ### Response: (Severity: 7), (Category: OS), (Description: PlaceD was unable to inform SysMgr that it had completed its initialization.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ALLOCATOR-3-LTRACE_INIT_FAILED ### Response: (Severity: 3), (Category: OS), (Description: Ltrace initialization failed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-CDI_SERVER_INIT_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: An error was encountered while the specified process was initializing. The error message contains details about the source of the error. Frequency synchronization is disabled.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-FALLBACK_MACSEC_SAK ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-4-DISK_WARN ### Response: (Severity: 4), (Category: HA), (Description: When some monitored disk's usage is above 80%.), (Recommended Action: The indicated disk device may be running out of space. Determine if there are unneeded files on the disk.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-SWITCHOVER ### Response: (Severity: 3), (Category: HA), (Description: You have configured switchover of RP on specified memory level. system collects debug information and checks feasibility of switchover and if allowed it will go ahead to do that. Node with memory hog will come backup as standby after reboot is over.), (Recommended Action: User need not do anything. Configuration will take care. Debug info saved on disk will help debugging the issue afterwards.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-6-UPDATE_DONE ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Package update requested on this satellite has completed. Run 'show nv satellite status' for more information.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cpuctrl Event Manager create error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-ERR_INVALID_DATA ### Response: (Severity: 3), (Category: MGBL), (Description: 'Wrong/Unknown Input'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in FIB MPLS. Typically, this is an error where the software fails during initialization. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid during initialization. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware during initialization/ configuration. - Resource limitations. This condition indicates a problem where the software has limited resources to operate on.), (Recommended Action: Please collect the console log and the CLI output. show cef show memory summary show cef location <> show memory location <> show cef trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_10_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_10 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-RUMP_NOTIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: Failed to notify RUMP about a newly registered protocol. See error message for more details. The result is that routes from the new protocol will not be redistributed into the multicast table.), (Recommended Action: Restart the RUMP process. *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-3-IM_STATE_ERROR ### Response: (Severity: 3), (Category: L2), (Description: PIRD encountered an error while trying send a state message to Interface Manager, and the error could not be recovered from by retrying. Interface Manager is likely to continue to wait for a response, and then shut down the affected interfaces.), (Recommended Action: The state operation is not essential to the operation of PIRD, so if no ill effects are observed then no action is needed. If the Interface Manager shuts the interfaces down unexpectedly, then try issuing 'no shutdown' for each affected interface, to refresh the state. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-CPP_PKT_F2_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: IBS from CPP packet FIFO 2 single bit error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-DB_CLEAR_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: Error encountered when attempting to clear the DB. DB might be in any state now & so usage of hat DB might fail with unexpected results.), (Recommended Action: Collect the output of show logging and inform Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Also, restarting the local DB process might help recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PM-5-MEMORY_LIMITS ### Response: (Severity: 5), (Category: MGBL), (Description: Perfmgmt server could not restore configured memory thresholds. Perfmgmt server will restore the defaults for memory limits.), (Recommended Action: Reconfigure the memory thresholds via cli.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-5-AAA_UNREACHABLE ### Response: (Severity: 5), (Category: L2), (Description: AAA process or Server is unreachable. Authentication will be reattempted), (Recommended Action: Check AAA connectivity by checking local radiusd client process and external AAA/EAP server connectivity) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-7-DEBUG_REGISTER ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when registering debug.), (Recommended Action: Restarting the process may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-7-SYSDB_FD_CLOSED ### Response: (Severity: 7), (Category: ROUTING), (Description: This notification indicates that RIB component is closing the connection with sysdb. Ignore the log if RIB or sysdb is restarting.), (Recommended Action: If RIB or sysdb is not restarting while this message is logged check if RIB show commands are working. This message is added to catch this exact scenario.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-4-WARNING_INFO ### Response: (Severity: 4), (Category: PLATFORM), (Description: Warning information during improper updation of variables or incorrect return state in MPLS FIB platform), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TP_SW-4-CLIENT_CONNECT_TIMEOUT ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates that Connect timer is timed-out for TP-LXC client), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_DLL-4-ERR_ASIC_CRC ### Response: (Severity: 4), (Category: FABRIC), (Description: CCSQ block received a packet with a CRC error. It is primarily caused by either the link errors between the devices or packet corruption in the upstream asic. This error may cause performance degradation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCID_SERVER-3-ERROR_CHKPT_TRAN ### Response: (Severity: 3), (Category: ROUTING), (Description: The MCID process encountered the specified error during checkpoint translation.), (Recommended Action: No action is required. Platform software will correct itself if this happens) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ITAL-7-ERR_RETRY ### Response: (Severity: 7), (Category: OS), (Description: Retry count exceeded the limit.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-4-ENCAP_REMOVED_PW ### Response: (Severity: 4), (Category: L2), (Description: Encapsulation in the pw-class is deleted, all non-static pseudowires attached with this pw-class will be unresolved as encapsulation type becomes unspecified.), (Recommended Action: Configure the pseudowire encapsulation in the pw-class and re-attach the pw-class to the pseudowires.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-3-MUTEX_LOCK_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The mutex lock for accessing register returned error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-6-SOCKET_BUFF_EXIT_STRING ### Response: (Severity: 6), (Category: PLATFORM), (Description: Trying to track the EXIT string. %x- Value of the socket buff at index 0 and 1 respectively.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-MLACP_ITEM_LOCAL_MISCONFIGURATION ### Response: (Severity: 5), (Category: L2), (Description: If there is a misconfiguration for an item that may be resolved without user intervention, then the item will be temporarily ignored. Once the misconfiguration is resolved, either by a resync of mLACP data or by the user, the item will no longer be ignored.), (Recommended Action: If the alarm does not clear, ensure that the configuration (on both local and peer device) is as expected.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-BP_IDPROM_NOT_AVAILABLE ### Response: (Severity: 3), (Category: DRIVER), (Description: The presence of the backplane IDPROM module is no longer detected by CCC FPGA, this might indicate some HW access commnication issue.), (Recommended Action: If both RPs in the system does see the same issue, then this could be HW issue on the backplane IDPROM module in the chassis. Try to power cycle the whole chassis to see if the problem is resolved. If this condition is only seen by one RP, then try to reload the RP to see if it can recover from the failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEM-6-PARAM_NOT_IN_RANGE ### Response: (Severity: 6), (Category: L2), (Description: A value in class attach onto interface or controller not inherited.), (Recommended Action: No Action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-EVENT_BLOCK_ERROR ### Response: (Severity: 3), (Category: MEDIA), (Description: Error during event block), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-3-NULL_CALLBACKS ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A statically linked NetIO DLL has invoked a NetIO API before the callbacks table has been initialized), (Recommended Action: If this message is seen then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of BGP soft reconfiguration? ### Response: BGP soft reconfiguration allows the router to store a copy of the routes received from a neighbor before any inbound policy is applied. If the inbound policy is changed, the stored routes can be re-evaluated without tearing down the BGP session. It is enabled with the neighbor soft-reconfiguration inbound command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-1-BKT_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Fabric arbiter driver detected a bkt module error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_6_LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-4-SITE_REGISTRATION_LIMIT_EXCEEDED_ON_CONFIG ### Response: (Severity: 4), (Category: IP), (Description: 'The newly configured limit is less than the current ' 'count of registrations.'), (Recommended Action: 'Issue clear lisp site for limit to take immediate effect.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ITAL-3-DEBUG_INIT_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Some error occurred in interactions with debug infrastructure. The text of the message displays the failed operation and the related error code. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CBQOSMIB-3-MEM_ALLOC ### Response: (Severity: 3), (Category: SNMP), (Description: The MIB had trouble allocating memory.), (Recommended Action: Collect required_info and provide them to TAC, and the collected information will be used only for internal diagnosis purpose, then restart the process via cli 'process restart mibd_interface') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-3-ERR_MSG_CLIENT_SEND ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in CPUCtrl driver due to client which tried to send message failed.The error string updates the client name reason for the message send failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-DEVCTL ### Response: (Severity: 3), (Category: HA), (Description: Failed to open procfs file or directory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEM-6-CNTRLR_INHERITED ### Response: (Severity: 6), (Category: L2), (Description: Inherited values from the class attached to the parent controller. If the parent controller of the interface has a cem-class attached, its values are applied, else reverted back to default values.), (Recommended Action: No Action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-3-FLAG_VALUE ### Response: (Severity: 3), (Category: L2), (Description: SPA shut and unshut is done based on the flag value from install director Based on the flag value in sysdb, API does shut or unshut of spa.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of BGP communities? ### Response: BGP communities provide a way of grouping destinations into communities and applying routing decisions based on the community. Each community is represented by a 32-bit value, with the format AS:NN. Well-known communities include no-export, no-advertise, internet, and local-as. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-3-SAK_CIPHER_MISMATCH ### Response: (Severity: 3), (Category: L2), (Description: The received cipher is not configured or supported), (Recommended Action: If received cipher is supported, change configuration at receive side or change cipher at KS to include the supported cipher) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_1_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ Tx power less than or equal to the low Tx power alarm threshold. The QSFP+ is the pluggable optics on the line cards. The Tx power threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Replace the QSFP+ with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LINEPROTO-5-UPDOWN ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: The data link level line protocol changed state.), (Recommended Action: If the state change was unexpected, confirm the configuration settings for the interface and line protocol.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSCMEDIA-4-THREAD_MUTEX_UNLOCK_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: DSC media DLL encountered an error while un-locking a mutex. The operation related to the resource may be affected while the system continues to run normally.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN-4-PD_RESYNC_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The SPAN EA was not able to update traffic replication programming in the hardware. It is possible that traffic will be replicated incorrectly at some source interfaces, and that hardware resources will not be released. Use 'show monitor-session status' to determine which interfaces are affected. Standard forwarding will not be affected.), (Recommended Action: This message is likely to indicate a problem with programming the hardware. Attempt to resolve any memory issues before attempting to solve the problem. If recently applied configuration changes have not been enacted in the hardware, reverting and then re-applying the configuration changes may help to resolve the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XML_TTY-7-SSLINIT ### Response: (Severity: 7), (Category: MGBL), (Description: An internal error has occurred in the XML SSL Agent. SSL library initialization may not be able to complete correctly.), (Recommended Action: Retry the XML request that had the error. Transient conditions should have passed, and in all likelihood, this request will go through. If not, close this TTY session, and restart a new TTY session. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GNSS-4-MEM_ALLOC ### Response: (Severity: 4), (Category: L2), (Description: The process failed to allocate memory for the specified resource.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOSHAL-6-QOS_MODE_UNSUPPORTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: 'A configured qos mode is not supported on this LC.'), (Recommended Action: remove configuration of the unsupported QoS mode.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-OOR_GROUP_RANGE_THRESHOLD ### Response: (Severity: 4), (Category: ROUTING), (Description: This router has reached the threshold value for the number of group ranges allowed to be received through the given group-to-RP mapping distribution mechanism. This is a warning that the maximum value is being approached and steps should be immediately taken to reduce the number of group ranges being distributed by the given mechanism or to configure a higher maximum value.), (Recommended Action: Consider reducing the number of group ranges advertised from some set of the candidate-RPs or consider reducing the number of candidate-RPs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_8_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-7-ERR_RACK_CREATE ### Response: (Severity: 7), (Category: PLATFORM), (Description: The RACK entry is a must in inventory management), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Inventory Manager process will restart automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDBHELPER-7-LOCKING ### Response: (Severity: 7), (Category: SYSDB), (Description: The client library has either failed to aquire or release a lock.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-CCTL_SENSOR_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The sensor initialization is not proceded due to invalid index entry.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_SYSMGR_MON_LIB-3-SYSMGR_CONN_LOSS ### Response: (Severity: 3), (Category: HA), (Description: Sysmgr failed to connect with vm-monitor.), (Recommended Action: This indicates an sysmgr process is hung or unable to communicate with watchdog.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEV2-7-SVC_DEBUG ### Response: (Severity: 7), (Category: OS), (Description: A service API debug is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rspp_rio_netio-3-INIT_TRACE ### Response: (Severity: 3), (Category: SERVICES), (Description: An error occurred during initialization of the trace facility. There will be no NetIO trace messages for service ingress diversion. The 'show services diversion rio netio trace' command on this node will not function correctly. Otherwise service ingress diversion will work correctly.), (Recommended Action: This is not a fatal error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-2-SDK_VRID_TCAM_NOMEM ### Response: (Severity: 2), (Category: PLATFORM), (Description: In VRRP non-scale mode DPA failed to program the vrid in 16 entry TCAM because the TCAM is FULL.), (Recommended Action: Move to VRRP scale mode by configure the hw-module vrrpscale enable and reload the line cards.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_HFR-7-ERR_EVENT_CONN_EVM_HANDLER ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to register event handler for the posix message queue. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-CARD_RELOAD_POST_SCAN ### Response: (Severity: 6), (Category: FABRIC), (Description: Recover the card with reload following ASIC scan.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-7-SYSCALL ### Response: (Severity: 7), (Category: HA), (Description: A system call failed in the wdsysmon library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-5-TCAM_INVALID_REG_NAME ### Response: (Severity: 5), (Category: OS), (Description: A Pre-IFIB region with unrecognized name is found in the TCAM.), (Recommended Action: Check the status of TCAM Manger because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-1-NO_POWER_AVAIL ### Response: (Severity: 1), (Category: PLATFORM), (Description: The system has attempted to powerup the target node, however the system does not have the electrical power needed to execute the request.), (Recommended Action: - Please collect the following CLI command to determine the current budget situation and to see if there are any failed power modules. admin show environment power-supply - Install additional power supply modules and in case of presence of failed power module(s), replace those unit(s). - After the above step, issue the following CLI command to attempt to reload the affected card: hw-module location reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-LINK_ANOMALY_SET ### Response: (Severity: 6), (Category: ROUTING), (Description: ISIS was notified of a link anomaly condition on the specified interface and has increased the per-level link metric as specified by the 'metric fallback anomaly' configuration.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp bestpath aigp ignore' command in IOS XR BGP configuration? ### Response: The 'bgp bestpath aigp ignore' command is used to disable the Accumulated Interior Gateway Protocol (AIGP) metric for best path selection. AIGP is an optional, non-transitive BGP path attribute that carries the accumulated IGP metric for the path. By default, if AIGP attribute is present, BGP uses it for best path selection. This command disables the use of AIGP in best path calculation. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_IM_INTERFACE_DELETE ### Response: (Severity: 3), (Category: ROUTING), (Description: Error while deleting an IM interface.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_ILMI-2-INTERNAL_MSG ### Response: (Severity: 2), (Category: L2), (Description: Internal error message. first %s - Type of failure second %s - reason for failure The error could be from various reasons. The message itself contains a good info.), (Recommended Action: Action to be taken based on the error message. In case of initilization/registration failures. Restart the atm_ilmi process for recovering. Check memmory conditions in case of memory related msg. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_STAT_VEC_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-1 state error on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-2-VIDMON_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The VidMon feature is configured without the necessary license.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-TCAM_ODS8_THRESHOLD_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: The TCAM utilization for the Logical Table (LT) ODS8 partition on a specific LC has exceeded the provisioned warning threshold (%)), (Recommended Action: Limit TCAM Logical Table (LT) ODS8 usage accordingly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-4-DLL_OPEN_ERROR ### Response: (Severity: 4), (Category: MGBL), (Description: The RS232 DLL was unable to open a DLL.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-ENS_PUBLISH ### Response: (Severity: 3), (Category: OS), (Description: RDS producer calls writer aquire and which in turn calls ens_publish. This call may be failed due to underneath transport issue.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-3-UNREG_PROC_FAILED ### Response: (Severity: 3), (Category: HA), (Description: Process un-registration for node memory state with wdsysmon is Failed.), (Recommended Action: Collect show tech watchdog and contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-INIT ### Response: (Severity: 3), (Category: SNMP), (Description: This is internal error while intialising the datastructure during snmpd process intialization.), (Recommended Action: Please restart snmpd process , if still noticed the error contact technical support representative with required info. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-MIB_TRAP_NFN_FAILED ### Response: (Severity: 4), (Category: L2), (Description: Frequency Synchronization was unable to perform a MIB notification for one of its configured traps. A MIB client listening may have missed a notification.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCMCIA-7-REG_PM_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: PM_FAULT_REGISTER_DEVICE registers a device instance with the fault report API. This step must be done before the device driver may report faults. It should be done at the init phase rather than when an error occurs. When registration of device instance failed, fault reports are not logged.), (Recommended Action: 'Check show process PCMCIAD output. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_QOSEA-6-LTRACE_INIT_FAIL ### Response: (Severity: 6), (Category: QOS), (Description: Ltrace initialization failed within EA. Ltraces may not be printed), (Recommended Action: Try restarting QoS EA process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-3-INTF_UPDATE_FAIL ### Response: (Severity: 3), (Category: L2), (Description: The Ethernet Link OAM Daemon was unable to record a change in the state or MAC address of one or more interfaces. This is likely caused by a memory resource allocation error.), (Recommended Action: Attempt to resolve any system resource constraints, and then issues 'process restart ethernet_link_oam_daemon' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_10_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_10 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_VM_INTR_PA_SOF_EOF_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_VM_INTR_PA_SOF_EOF_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-2-CHASSIS_SHUTDOWN_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: The shutdown of the chassis was unsuccessful due to the reason mentioned in the message .), (Recommended Action: Chassis shutdown is typically initiated due to some critical failure. As the software initiated chassis shutdown has failed, the user should intervene and shut down the chassis manually.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_PERSIST_RETRAIN_LINK ### Response: (Severity: 1), (Category: PLATFORM), (Description: An ASIC error has occured and cause retrain link.), (Recommended Action: An error that causes retrain link has happened and been handled *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT-0-XFI_TRANSIVER_RESET_FAIL ### Response: (Severity: 0), (Category: PLATFORM), (Description: FPGA XFI initialization failed.), (Recommended Action: The software is not able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-1-FC_I2C_ERROR_OR_TO ### Response: (Severity: 1), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_VPLS-3-G8032_J2_CONFIG_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: G8032 is not supported on LCs that have names starting with NCS57.), (Recommended Action: Remove the unsupported interfaces from G8032 config.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-4-EA_LIB_CLEANUP_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The Ethernet Link OAM EA failed to clean up correctly. It will exit anyway, and no further errors should be seen.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-IDB_LOST_GROUPS_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace im error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace im error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp groups summary command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp groups summary output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-7-RACK_DELETE ### Response: (Severity: 7), (Category: PLATFORM), (Description: While trying to update the new rack entry values from sysdb, Failed to remove the old ones.It will anyway go ahead and rewrite the existing ones with the new ones.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR-3-LIB_REG_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Registration with an external library failed. This may be a program level error. The failure will cause the Procmgr process to restart.), (Recommended Action: The Procmgr process will automatically respawn up to a fixed number of times. Verify the process is running: 'show process procmgr location <>' If it is still not spawned contact support with the required info. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-TTY_MGMT_SCAN ### Response: (Severity: 3), (Category: MGBL), (Description: The call to tty_mgmt_scan() failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY_DB-2-PANIC ### Response: (Severity: 2), (Category: MGBL), (Description: A critical internal error has ocurred which requires the process to restart. For example if a lock cannot be released then the process is restarted to avoid deadlock.), (Recommended Action: Please get the information specified under the component required_info and call your Cisco technical support representative and provide the gathered information with this error message text. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_12_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLUTLU-3-MIPC_NOTIF ### Response: (Severity: 3), (Category: PLATFORM), (Description: TLU received notification from MIPC due to unrecoverable error or invalid address. client downloads the entire table to hardware as a recovery mechanism. This is an informational message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-2-LC_IDENT_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Hardware in the specified location could not be verified as a genuine Cisco product.), (Recommended Action: Please copy the error message exactly as it appears on the screen and gather the output of CLIs 'show diag eeprom-info', 'show tech-support ethernet interfaces'. Please ensure that the line card daughter board card type, board PID and serial number are not modified. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are BGP update groups and what are their benefits? ### Response: An update group is a collection of peers with identical outbound policy. On IOS-XR, peers with the same outbound policy are automatically assigned to the same update group. Update generation is done once per group, conserving resources. Debugs also operate at the update group level. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ct_agent-3-ERR_CT_INIT ### Response: (Severity: 3), (Category: SECURITY), (Description: A failure occured during the initialization of the process. This may have resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-6-ERRMACRELOAD ### Response: (Severity: 6), (Category: INFRA), (Description: MAC error were detected.), (Recommended Action: To determine why this problem occurred, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet' and 'show tech-support ctrace' commands. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_8_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_8 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV6-3-ERR_STR ### Response: (Severity: 3), (Category: L2), (Description: Platform IPv6 FIB, error information), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace [common|ipv6] all loc <>). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EDRM_DLL-3-FREE_ALL_RSRC_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The freeing all resource operation failed for the client due to the reason.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-PROC_RPC_OPERATION_NAME ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA_TP-3-ETMM_EARF_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Internal error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-6-DIAGNOSTIC_INFO ### Response: (Severity: 6), (Category: DIAG), (Description: An Info message for the diagnostic.), (Recommended Action: This is an info message, no need to take any action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-SESSION_LIMIT ### Response: (Severity: 3), (Category: SECURITY), (Description: Attempted to create SSH Sessions more than configurd maximum), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-2-RECOVER_BACKUP_BIOS_BOOT_FAILED ### Response: (Severity: 2), (Category: DRIVER), (Description: The device is detected to be booted from backup BIOS. Backup BIOS is only to debug the problem with the main BIOS but system can't run with it properly. Hence, tried recovery, but failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Log will be collected in /misc/disk1/log directory in admin prompt 1. Copy the log collected in /misc/disk1/log directory in admin prompt 2. show tech card-mgr 3. show tech ctrace) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-5-CARD_RELOAD ### Response: (Severity: 5), (Category: OS), (Description: SSM Process is taking recovery action for the failing service. Reload is the specifed recovery action for this service.), (Recommended Action: Collect show tech ssm. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKI-3-ERR_GENERAL ### Response: (Severity: 3), (Category: SECURITY), (Description: CEPKI general error message with one prameter.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_4_LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature less than or equal to the low temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CPAK with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-3-CONFIG_INVALID_NODEID_CLEAR ### Response: (Severity: 3), (Category: L2), (Description: The misconfiguration that had been caused by invalid multi-homing node IDs has cleared either through local configuration or by the remote peer.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MANSDORF-3-NO_INTR_HANDLER ### Response: (Severity: 3), (Category: PLATFORM), (Description: A critical condition occurred in MANSDORF layer. The message string indicates the reason for the failure. Here is a list of possible reasons for this message (not all-inclusive). - No interrupt handler. This condition indicates a problem with the software when there is no interrupt handler for MANS.), (Recommended Action: Please collect the console log and the CLI output. show logging show running-config show cli history detail loc <> sh plim services trace driver info sh plim services trace driver error show tech-support location <> show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-PROVISION_PRE_CHECK_VM ### Response: (Severity: 4), (Category: MEDIASVR), (Description: This ios_msg is raised when provision prechecks are performed on the disk/system), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBCSVI_BILLING-3-PATHERR ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the creation of an sbc billing cache path. SBC billing application will not be able to save billing records), (Recommended Action: Make sure that the the drive needed for the type of SBC billing you need (local or remote) is mounted and formatted. Delete the SBC instance and create again to mount the SBC billing drives.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPM-3-ERROR_PTHREAD_SET ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_EVC_ERROR ### Response: (Severity: 4), (Category: L2), (Description: After detecting an error with the connection to the specified service, PPP MA failed to reset that connection. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-7-ERR_LWM_EVENT_BLOCK ### Response: (Severity: 7), (Category: PLATFORM), (Description: ClkCtrl Event Manager event block error), (Recommended Action: Please attempt to correct the error by restarting the process. Issue the command in exec mode -process restart dao_tmp If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: METRO_STATS_API-7-ERR_THREAD ### Response: (Severity: 7), (Category: L2), (Description: This error indicates that the Hardware Stats Manager Library is unable to initialize/destroy locking for client's attributes and tables.), (Recommended Action: An error was returned by Stats Manager APIs to applications. Applications receiving this error will report it. Take recommended actions specified in the application's error message. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-CDR_MSG_REPLY_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric:CDR driver LWM message reply failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-3-ERR_LTRACE_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Interrupt controller Driver Ltrace initialization failed.), (Recommended Action: Please attempt to correct the error by restarting the process. Issue the command in exec mode -process restart longbeach If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JBI-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message from the altera JTAG player, it indicates that something has gone wrong with FPGA programming.), (Recommended Action: File a DDTS) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-EXTRANET_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred in MRIB MVPN EXTRANET operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-INVALID_OPTION_ERR ### Response: (Severity: 3), (Category: L2), (Description: The operation is failed due to an internal software error. Software will take action as described in the error message to try to recover from the error. The hardware error and the software recovery action will cause linecard reload. %s - description %x - option value), (Recommended Action: Check if the linecard reported any other errors. May need to restart process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_IN_MEM_UCORR_ECC_ERROR_LNK3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast input memory uncorrectable ECC error on link 3), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_8_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_DISPARITY_ERROR_8 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-2-LC_EOBC_FAILED_STBY_RSP ### Response: (Severity: 2), (Category: PLATFORM), (Description: This line card has lost EOBC heartbeat to the standby RSP.), (Recommended Action: If this happens during system booting and switchover or when the standby RSP is not in 'IOS XR RUN' state, this message can be safely ignored. Otherwise, If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-VOLTAGE_SUPPLY_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Software periodically reads voltages on fabric cards. If the voltage read is outside of valid range, this message will be displayed.), (Recommended Action: This condition indicates a potential hardware problem with the card. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSUDIR-1-OPERATION_ABORT_PKG_MISSING ### Response: (Severity: 1), (Category: INSTALL), (Description: ISSU operation aborted due to the displayed error.), (Recommended Action: The error message from install, included as part of this output, may make the cause of the failure clear, in which case appropriate action should be taken to remedy the problem. If the issue is not clear from the message then the reason for the failure will need to be analyzed; collect the output of 'show tech-support issu' and 'show tech install' and forward the logs to the TAC. Provide details of any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-4-DISTRIB_RECONNECT_FAILED ### Response: (Severity: 4), (Category: INFRA), (Description: The SLA Client Library has failed to resync the configured profiles with the Profile Manager after one minute of retrying. Further retries will be attempted every 30 seconds. Until the client is resynced with the SLA Profile Manager any recent additions or changes to profile configuration will not be acted upon. Note: if SLA is not configured for the protocol which emitted this error message there is no effect and this error can be ignored.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REBOOT_LIB-6-SDR_NM_ACK_RCVD ### Response: (Severity: 6), (Category: INFRA), (Description: Inormational message that SDRNM acked reload request), (Recommended Action: None No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-2-ASYNC_SHMWIN_RECOVER ### Response: (Severity: 2), (Category: IP), (Description: The socket library has encountered an error while using one of the shmwin API for ASYNC sockets. This indicates that there is in-consistency in the shmwin window and it is no more in usable state.), (Recommended Action: The information in required_info to be collected. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_CLIENT-3-CONFLICT_ISSU_FLAG ### Response: (Severity: 3), (Category: HA), (Description: When chkpt is used by multiple DLLs from within the same process context, they all need to specify same value for shared memory reuse flag.), (Recommended Action: Save the above error message. Note down the component ID from the above error message and open a DDTS against that component and attach this error message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KENSHO_GL-4-WARNING ### Response: (Severity: 4), (Category: PLATFORM), (Description: Topaz LC Kensho-GL CPU Subsystem DLL warning message. No system functional impact.), (Recommended Action: Nothing. Reporting normal progress of Topaz LC Kensho-GL CPU Subsystem DLL.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-TRANSACTION_PENDING_FLAG ### Response: (Severity: 3), (Category: ROUTING), (Description: Failed to clear, set, or get transaction pending flag. That can only happen if the APIs to do that are called before shared mem window is opened, or if thereis a bug), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-NPU_0_FC_OOS_3 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress flow control out-of-sync on NPU-0 interface on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-5-PLIM_KA_INIT_ERR ### Response: (Severity: 5), (Category: L2), (Description: Creating SPA keepalive server failed.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure BGP confederation in IOS XR? ### Response: BGP confederation is configured in IOS XR to divide a large autonomous system into smaller domains for easier management. router bgp 65000 bgp confederation identifier 65001 bgp confederation peers 65002 65003 commit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-INVALID_ARGS ### Response: (Severity: 7), (Category: OS), (Description: A function was invoked with invalid arguments This is a generic error message and happens when the calling function invokes the caller function with invalid arguments), (Recommended Action: This is a Debug message. No action required. If problem persists,contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEM-3-CLASS_FAIL ### Response: (Severity: 3), (Category: L2), (Description: An API call in cem_class process failed. First %s - Type of Error Second %s - Reason), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RAW-7-SOCKET_INIT ### Response: (Severity: 7), (Category: IP), (Description: An software error occured when the RAW process do socket related initialization.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-4-MULTICAST_THRESHOLD_CROSSED_LNK1 ### Response: (Severity: 4), (Category: PLATFORM), (Description: Crossbar driver detected multicast queue utilization is over configured threshold.), (Recommended Action: This is a transient alarm and should clear when the multicast input traffic rate reduces. Please check multicast traffic and alarm threshold configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-3-MAP_INFO_FAILED ### Response: (Severity: 3), (Category: OS), (Description: Core dump failed because the target process information is not available with dumper. It is because of system call failure or memory shortage. Core file will be truncated.), (Recommended Action: Possible Work Around: If there was dumper malloc failure, try following command for failed process. 'show proc | include COPY' If it would produce something like following output, core: COPY then dumper COPY option is enabled for this process and it temporary consume a lot of memory, so it might be one of the cause of the memory shortage problem. If that is the case, then specifing following command for failed process will reduce the temporal memory usage of the process, thus it might work around the problem. 'proc core ' Collect the following data and contact support. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_GET_NODE_TYPE ### Response: (Severity: 3), (Category: OS), (Description: The system failed to get node type.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-6-ERR_TX_CONN ### Response: (Severity: 6), (Category: FABRIC), (Description: Ingressq ASIC has 32 TX links into the fabric planes. This message lists the fabric planes that cannot be used by the Ingressq ASIC for data traffic.), (Recommended Action: If these fabric planes have not been installed, please ignore this message. If these fabric planes have been installed, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GIRO-4-CFG_SAVE ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Configuration for a batch of interfaces could not be saved prior to the interfaces being deleted.), (Recommended Action: When these interfaces are re-created, re-enter desired configuration manually.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_LOCAL-6-EA_DLL_INFO ### Response: (Severity: 6), (Category: L2), (Description: Debug messages for sonet ea edh dll.), (Recommended Action: No Action requirements.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WAN_LIB_VCC-3-NOMEM ### Response: (Severity: 3), (Category: L2), (Description: The system is low on memory and not enough was available to complete the request), (Recommended Action: Check the box for processes with excessive memory. If the problem persists collect the required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-SAMESYSID_DIFFHOST ### Response: (Severity: 4), (Category: ROUTING), (Description: An LSP is received with a System ID same as the local System ID but with a different hostname. This could be happen in the following cases: 1) A new router is introduced into the network with a duplicate system ID as the local router. 2) The local hostname has changed and isis is receiving an old LSP generated with the old hostname.), (Recommended Action: If case 1, Check the configuration of other routers in the area for duplicate system IDs. If case 2, Ignore the message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-7-DEBUG_INIT_EVENT ### Response: (Severity: 7), (Category: IP), (Description: The socket library (used by transports) failed to initialize a debug event.), (Recommended Action: The transport process will try to recover from this by retrying/ restarting. If the messages are not seen again, the problem was transitory and has been recovered. There is no need to take any action. If the messages come continuously, take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-SATELLITE_CAPABILITIES ### Response: (Severity: 3), (Category: L2), (Description: An error was encountered while attempting to retrieve capabilities for Satellites. CFM may fail to function correctly on the Satellites affected.), (Recommended Action: If the error is the result of a configuration change, remove and reapply the configuration. If this does not work, or the error was otherwise triggered, then try restarting the CFM Daemon using the 'process restart cfmd location ' command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-3-ACP_CHANNEL_TO_NBR_FAILED ### Response: (Severity: 3), (Category: SERVICES), (Description: 'Autonomic Network Control Plane Channel has not been ' 'created to the neighbor'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VASI_NETIO-3-DROPPED_PACKETS ### Response: (Severity: 3), (Category: SERVICES), (Description: An error has occured during packet handling in the VASI base capsulation, and no error counters can be updated. If errors are seen for an extended period then it can be assumed that no packets can be forwarded through VASI interfaces. This is likely to be a symptom of a problem in the Packet Forwarding Infrastructure - earlier error messages might indicate the root cause of the problem.), (Recommended Action: If the errors stop after a couple of minutes while traffic is still flowing through the VASI interfaces then it can be assumed that the problem has resolved itself. If the problem continues, then unconfiguring and reconfiguring the VASI interfaces could fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-7-ASMP_PCI_DETAILS ### Response: (Severity: 7), (Category: PLATFORM), (Description: Details about the error observed on the PCI bus with Atlantis system controller.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP_VRF-3-MAX_IMPORT_RTS ### Response: (Severity: 3), (Category: ROUTING), (Description: The import RT is failed to be added to the vrf due to the maximum allowed number of import RTs for each vrf.), (Recommended Action: Review the import RTs of the vrf and try to reduce the number of import RTs for the vrf.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG_PLAT-3-SHELFMGR_EBUSY_RETRY ### Response: (Severity: 3), (Category: INSTALL), (Description: Retry registration fixed number of times. Got EBUSY in registration with shelfmgr , retry if failed.), (Recommended Action: Please contact TAC after trying maximum retries.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-WARN_VLAN_SES_THRESHOLD_EXCEED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions for a particular VLAN on the given access interface has exceeded the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-6-CF_OIROUT ### Response: (Severity: 6), (Category: PLATFORM), (Description: Compact Flash entity is removed from the RSP invmgr_agent deletes the CF data whenever it is removed.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_BA_INTR_PA_STALLED_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_BA_INTR_PA_STALLED interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSVP-3-RSVP_TRACE_INIT_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: RSVP could not initialize the event tracing module), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What operations can IOS XR processes perform on the SysDB? ### Response: IOS XR processes can perform the following operations on SysDB\n- Retrieve config and state data\n- Create, modify, and delete config data (for config-owning processes)\n- Register for notifications when data nodes are modified\n- Validate and reject config changes (for config-owning processes)\n- Store ephemeral and persistent state data\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMIB_IFSPECIFIC_CLIENT-6-ERR_DBG_FAILED ### Response: (Severity: 6), (Category: SNMP), (Description: The operation requested could not be performed due to an internal error.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INFRA_TEST-7-SOLICITED_B ### Response: (Severity: 7), (Category: TEST), (Description: A solicited message with an integer arg, a string arg, and an interface.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AIB-4-CLDATA_ZERO_REFCOUNT ### Response: (Severity: 4), (Category: ROUTING), (Description: AIB has reached zero refcount for clientdata. This indicates the accounting is incorrect.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_0_ERR2_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 0 ran into error-2 on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_32 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_IPV6_EA-3-ERROR2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Here is a list of possible reasons for this message (not all-inclusive). - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Resource limitations. This condition indicates a problem where the software has limited resources to operate on.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show memory summary show cef ipv6 location <> show memory location <> show cef ipv6 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-2-ASIC_ERROR_THRESHOLD_CARD_SHUTDOWN_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Uncorrectable asic errors occured on card and board could not be shut down), (Recommended Action: ASIC errors that are uncorrectable have occured and exceed the threshold. Card could not be shut down because of some errors. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCDS-7-DEBUG ### Response: (Severity: 7), (Category: OS), (Description: Internal debugging message.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-4-NO_SA ### Response: (Severity: 4), (Category: SECURITY), (Description: No security association exists for this packet and it is not an initial offer from the peer to establish one. These errors could imply denial of service attack.), (Recommended Action: 'Contact the remote peer and/or his administrator') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMACTRLR-4-ALARM ### Response: (Severity: 4), (Category: L2), (Description: The specified IMACTRLR Alarm has been declared or released.), (Recommended Action: Recommended action is to repair the source of the alarm.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCMD-3-ARCHIVE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Transfer of RCMD report for archival purpose has failed.), (Recommended Action: This indicates that RCMD reports have not been archived in persistent storage. In the event of RCMD process restart along with RP FO/SO the information collected can be lost. The archival location configuration needs to be verified to be accessible and that sufficient storage space is available at the location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-RX_ALARM_LOF_SYNC_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: The BITS receiver has detected OOF defect for incoming signal. For T1 mode OOF is declared when out of every four frame bits two or more frame bits are received in error. For E1 mode OOF is declared when three consecutive incorrect FAS is received. Also for E1 mode(CRC-4 framing) OOF can be declared when 915 or more CRC blocks out of 1000 are received in error. Additionally for E1 mode(CAS signalling) OOF can be declared when two consecutive multiframe alignment words are received in error or, for a period of one multiframe, all bits in timeslot 16 are zero.), (Recommended Action: 1) Ensure framing format on port matches framing format on the line. 2) Configure to other framing format to check if error clears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-6-IPV6_MTU_TOOSMALL ### Response: (Severity: 6), (Category: INFRA), (Description: XLNCd is responsible for keeping the networking stacks for IOS-XR and Linux synchronized. It has observed that the MTU configured in IOS-XR has changed, and mirrored the new value into Linux, but that value is less than the minimum supported value for IPv6. The Linux kernel will automatically remove all IPv6 addresses from the interface, and will not re-add them when the MTU is raised, so they must be re-added manually.), (Recommended Action: Raise the MTU above the minimum value of 1280 required for IPv6, and re-add the MTU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTP0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-OOR_PER_INTERFACE_ROUTE_INTERFACE_THRESHOLD ### Response: (Severity: 4), (Category: ROUTING), (Description: This router has reached the threshold value for the number of states allowed to be received through the given interface. This is a warning that the maximum value is being approached and steps should be immediately taken to reduce the number of current states or to configure a higher maximum value.), (Recommended Action: Consider increasing the limit of states per interface, or decrease the current number of states for the given interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-DYING_GASP_USER ### Response: (Severity: 3), (Category: SNMP), (Description: Dying gasp has been enabled on a host for which v3 user is not yet configured.For such hosts dying gasp trap cannot be generated.), (Recommended Action: Ignore if this message was seen on snmp startup. Or configure valid snmp v3 user.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN-4-CHKPT_HW ### Response: (Severity: 4), (Category: L2), (Description: The SPAN EA encountered an error while trying to recover hardware programming information based on checkpointed records. The records are used to ensure hardware resources are cleaned up correctly; if an error has been enountered then it is possible that traffic will continue to replicated from sources or to destinations on the affected node even after configuration has been removed. Standard forwarding will not be affected.), (Recommended Action: If it appears that traffic is being replicated incorrectly, then re-enabling, and then disabling traffic replication for the affected interface may help to resolve the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-CHECKPOINT_NOSPACE ### Response: (Severity: 3), (Category: OS), (Description: A QSM checkpoint record could not be placed in the checkpoint file due to insufficient heap space.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRG-4-ASSERT ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The SRG process hits some abnormal condition. These warnings will not affect functionality of SRG.), (Recommended Action: Collect the traceback associated with this Log and contact the engineer.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA_TP-3-ETMM_AOF_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Internal error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GT_I2C-3-GET_NODEID ### Response: (Severity: 3), (Category: PLATFORM), (Description: As shown in the message.), (Recommended Action: Please collect required_info log/trace and contact Cisco technical support representative with required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_LIB-3-INFRA_BLOB ### Response: (Severity: 3), (Category: INSTALL), (Description: The Install infrastructure was unable to access some of the data that it requires, and so the requested operation may not be completed.), (Recommended Action: Please retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-4-MAX_NEIGHBORS ### Response: (Severity: 4), (Category: ROUTING), (Description: Reached maximum number of neighbors supported.), (Recommended Action: Reduce the scale of peers attempting to establish sessions with this router) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_CFG-2-MDB_PROFILE_INACTIVE ### Response: (Severity: 2), (Category: FABRIC), (Description: hw-module profile npu native-mode-enable command needs to be configured, for hw-module profile mdb config to work.), (Recommended Action: Enable npu native mode to configure hw-module profile mdb command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-7-CIS_DATA_READ_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: CIS data read error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN-3-APPLICATION_TRANSLATE_ERR ### Response: (Severity: 3), (Category: OS), (Description: SHMWIN encountered a data translation error. Client data is not updated.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-LSP_SOFT_PREEMPTED ### Response: (Severity: 5), (Category: ROUTING), (Description: The specified interface, with the specified LSP Id, has received a path \ error message and will be soft preempted.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_ALLOC-7-ERR_CHKPT_ITERATE_START ### Response: (Severity: 7), (Category: FABRIC), (Description: The FGID Allocator was unable to start to iterate checkpoint table. The fgid_allocator process may need restarting, if the errors persist.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-GET_MSGLEN ### Response: (Severity: 7), (Category: HA), (Description: Extracting message or source message length failed.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-ADD_KEY_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: IKE found failure when adding key), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-CHKPT_XFORM_INVALID_DIR ### Response: (Severity: 3), (Category: ROUTING), (Description: The TE checkpoint table translation library was invoked with an invalid translation direction.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Collect: -show logging -show tech-support mpls traffic-eng) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-6-VRF_DELETED ### Response: (Severity: 6), (Category: IP), (Description: The administrator deleted a VRF or a specific addrses-family in a VRF.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GRID-4-BANK_MAX_CLIENT ### Response: (Severity: 4), (Category: L2), (Description: All the network resources associated with this BANK have been completely exhausted and display client using highest rids of the bank.), (Recommended Action: The network operator could try and reduce the clients using high rids in the bank which would free up the rids. For eg. 1. If the GLIF bank 1 is full, mpls_lsd client is highest consumer. reduce the scale of mpls_lsd client labels.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_LOCSW-7-PFI_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the PFI-IFH module in the platform L2FIB LOCSW component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CBQOSMIB-3-MUTEX ### Response: (Severity: 3), (Category: SNMP), (Description: The MIB had trouble locking/unlocking mutex.), (Recommended Action: Collect information as in required_info. Collect running core dump via cli 'dumpcore running mibd_interface', and contact TAC. Then restart the process via cli 'process restart mibd_interface') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBMIRROR-3-ERR_CREATE_THREAD ### Response: (Severity: 3), (Category: MGBL), (Description: 'pthread_create() API failed due to mentioned error'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-7-CAL_CHIP_MAP ### Response: (Severity: 7), (Category: MGBL), (Description: Mapping calender chip address to process address space.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-5-CARD_INSERTED ### Response: (Severity: 5), (Category: PLATFORM), (Description: Given card has been inserted into the chassis.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_BA_INTR_QUEUE_LEN_URUN_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_BA_INTR_QUEUE_LEN_URUN interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-3-ERR_MEMBER_ADD ### Response: (Severity: 3), (Category: L2), (Description: Could not find the bundle interface with the nodeid and group. Hence cannot add the member interface to bundle.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please collect the required_info and contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA-3-RTINSERT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: A radix tree internal error occured while inserting in MPA multicast database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-4-DISTRIB_SEND_FAILED ### Response: (Severity: 4), (Category: INFRA), (Description: The SLA Profile Manager has failed to resync the configured profiles with its clients after one minute of retrying. Further retries will be attempted every 30 seconds. Until the clients become resynced with the SLA Profile Manager any recent additions or changes to profile configuration will not be acted upon.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-MTU_WARNING ### Response: (Severity: 4), (Category: L2), (Description: The E-LMI specification assumes that the MTU of the media that it is running over is exactly 1500 bytes. However, the protocol can run on lower values than this so long as the MTU is large enough to include a header, the report type IE, the sequence numbers IE, the data instance IE and a maximum length UNI IE. The message has been issued because the configured MTU is too small to meet this condition. The protocol will continue to run assuming that the MTU is this minimal required value and so may not operate correctly.), (Recommended Action: Reconfigure the interface's MTU to a larger value.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-5-CLOCK_INTERFACE_0_OUTPUT_SQUELCHED ### Response: (Severity: 5), (Category: PLATFORM), (Description: When no external clock source is available, this status propagates to BITS output ports in 2MHz and 6.312MHz modes. When an external source is qualified, this alarm will be cleared.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-6-SENDTO ### Response: (Severity: 6), (Category: L2), (Description: The socket call to send a control packet timed out.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. A Socket level error, nothing to be done.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-NO_SATELLITE_AVAILABLE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The received and parsed GPS TOD message frame from external equipment indicates no satellite availablity, which could possibly indicate that the time-of-day received is not synchronized to a UTC/TAI timescale.), (Recommended Action: 1) Ensure GPS receiver connectivity on the external equipment.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_11_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_11 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-INSTALL_CRITICAL_AUTO_ABORT ### Response: (Severity: 2), (Category: INSTALL), (Description: The install operation will abort in the given time unless the user starts either the accept phase or the complete phase using the supplied instructions. The critical version is shown if the abort timer has less than 30 minutes left on it.), (Recommended Action: Please take necessery actions as per the supplied instructions. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-4-ERR_MULTICAST_ADDR_SET ### Response: (Severity: 4), (Category: L2), (Description: The driver returned an error while setting up the CDP multicast address. It is possible that CDP packets will be dropped and not reach the CDP process.), (Recommended Action: If CDP packet loss is seen then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG_PLAT-7-IO_FAIL ### Response: (Severity: 7), (Category: INSTALL), (Description: Failed to read or write to the specified file, which is required to proceed further. The current request or operation may not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-4-ERR_LTRACE_INIT ### Response: (Severity: 4), (Category: FABRIC), (Description: The NPU driver could not open/initialize the ltrace buffer. The NPU driver and the system should stll function as normal, with the exception that ltrace will not be available for npu_drvr process.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIV2_DM-3-INFO ### Response: (Severity: 3), (Category: L2), (Description: Driver manager encountered an error that would lead to degraded service.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_THOR_L2FIB_LOCSW-7-INIT_WARNING ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the LOCSW module in the platform L2FIB LOCSW component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-BD_BATCH_DELETE_FAILED ### Response: (Severity: 4), (Category: L2), (Description: Following a configuration change, CFM no longer needs to retain information about some bridge domains but has failed to delete the information from its database. The process will continue to operate correctly but is using more memory than is necessary.), (Recommended Action: No specific action is needed, though the warning could be a sign of low memory conditions. If other memory issues are seen, resolve those first and then reapply the configuration change.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-3-MUTEX_ISSUE ### Response: (Severity: 3), (Category: FABRIC), (Description: --), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_0_ERR2_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 0 ran into error-2 on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_EVM_CONN_OPEN ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-2-TE_UNSUPPORTED_TRANSITION ### Response: (Severity: 2), (Category: ROUTING), (Description: In label update, unsupported transition to tunnel label.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-3-SPAN_FILE_WRITE_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An error was encountered while writing to the SPAN file.), (Recommended Action: This problem may indicate there was an issue with writing to file. You can try the operation again. If problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-4-WARN_ERR ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is an severe error message in the DPA module to indicate that an error was seen during init operation.), (Recommended Action: Please collect the console log, DPA traces (show dpa trace loc <>), Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE2_CODE_ERR_HIGH_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE2_CODE_ERR_HIGH interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GT_ETH_MGMT-3-DEBUG_REG_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error detected when registring the eth mgmt debug messages. process will restart automatically to recover from this error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_PRM_SERVER-3-SHMWIN_LOCK_DAMAGED ### Response: (Severity: 3), (Category: L2), (Description: The shared memory window lock, used by the primtive resource manager process, is corrupted. All particpant processes in the shared memory window are restarted to recover the system.), (Recommended Action: The linecard may need to be reloaded if it starts showing persist error log messages.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-L2VPN_RD_LOCAL_AND_REMOTE ### Response: (Severity: 4), (Category: ROUTING), (Description: BGP detected that the RD is marked both local and remote This means that the local table_ctx points to this rdinfo but this rdinfo points to the shared tabel_ctx), (Recommended Action: This msg is info only. At this point BGP and L2VPN will be out of sync Need process restart to achive sync) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_1_LOSS_OF_SYNC_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Loss of sync on NPU-1 interface on bridge instance-1.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_NETIO-3-PARSER_NULL_PATH ### Response: (Severity: 3), (Category: L2), (Description: The path to atm_netio.rules file cannot be located.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-ISSU_OP_ABORT_DSC_SWITCHOVER ### Response: (Severity: 2), (Category: INSTALL), (Description: During ISSU operation, a dSC switchover occurred unexpectedly thus the current ISSU operation is aborted.), (Recommended Action: Please retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_ACL-4-IPACCESSUNSUPPORTED ### Response: (Severity: 4), (Category: ACL), (Description: An access list that contains object-groups in one of its entries was specified. At this time ACLs with object-groups are supported only for packet filtering. I.e., attached to an interface.), (Recommended Action: Specify an access list that does not specify any object group in any of its entries.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-ERR_RCV_PAKTYPE_NOT_P2P ### Response: (Severity: 6), (Category: ROUTING), (Description: The packet is invalid because it is a LAN packet received on a P2P interface. The packet has been ignored.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-6-SETSOCKOPT_NOPROTOOPT ### Response: (Severity: 6), (Category: IP), (Description: An error occurred whilst trying to setsockopt on the socket. Session will continue.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-6-GOLDXR_GENERAL ### Response: (Severity: 6), (Category: DIAG), (Description: GOLD-XR general information.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: d1qnetio-3-IDB_NOT_FOUND ### Response: (Severity: 3), (Category: L2), (Description: The software forwarding support for IEEE802.1Q VLANs was unable to process a message sent to a particular interface because the interface does not exist in NetIO. Software forwarding VLAN functionality on the affected interface may be impaired. The interface can be determined from its handle with show im chains ifhandle [handle].), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-5-PORT_CONTROL_ADD_CLIENT_SUCCESS ### Response: (Severity: 5), (Category: L2), (Description: Port Access is allowed for the client.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_FSDB_FADB_LTRACE-3-ERROR_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: The FSDB FADB ltrace lib failed to initialize the error ltrace), (Recommended Action: Search the event logs for events/errors related to the failure reason. Ltrace usage is common to overall system. If there are failures here then other processes may also exhibit similar problems. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6-3-PAK_SEND_TO_TRANSPORT_FAILED ### Response: (Severity: 3), (Category: IP), (Description: IPv6_IO attempted to write a packet to the transport layer and failed.), (Recommended Action: Restarting the process may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-XFP_HOTSWAP_PERSIST ### Response: (Severity: 3), (Category: L2), (Description: The inserted XFP failed to power on correctly.), (Recommended Action: Replace the XFP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-CHECKPOINT_CANT_RELOAD_NOTIFY ### Response: (Severity: 3), (Category: OS), (Description: A link found in the checkpoint file could not be created in the QSM database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LIC_MGR-3-LISTENER_ERROR ### Response: (Severity: 3), (Category: OS), (Description: A component registered for platform mode notifications and the listener failed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-SW_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: The PLIM process failed to spawn due to an internal software problem during the initialization process. The process will automatically respawn up to a fixed number of times to try and recover. The PLIM process is the driver for all PLIM hardware devices. %s - indicates the reason for the failure.), (Recommended Action: Check if the linecard reported any other errors during the boot process as this error is normally associated with larger system issues. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_ASR9K_LIB-3-FAILURE_TO_BIND_TO_SYSDB ### Response: (Severity: 3), (Category: PLATFORM), (Description: The platform library service call to bind to system database module has failed. The calling application handles it appropriately.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-BUNDLE_FSV_REGISTER_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: CLNS failed to register with packet manager for FSV area. It only affects the algorithm used to pick a bundle member. If no bundles are configured for ISIS - this error can be ignored.), (Recommended Action: If the error was seen when a> packet process is restarting, then restarting NetIO will help recover from it {or} b> If the error is seen in normal conditions it indicates that packet process for some reason is not able to handle the FSV registration request. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. show tech-support pfi all show process packet location <> show process netio location <> show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-FILE_VERSION_MISMATCH ### Response: (Severity: 7), (Category: OS), (Description: A file has invalid version than expected.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN-6-OPEN_FAILED ### Response: (Severity: 6), (Category: OS), (Description: SHMWIN encountered an error condition, the shm open failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture - show logging - show shmwin trace all location 0/x/CPUx - Check that the path exists with 'run ls -l ' from the shell) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-MSG_READ ### Response: (Severity: 7), (Category: HA), (Description: A msg_read call in the message handler failed.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-1-ERR_ASIC_GENERIC ### Response: (Severity: 1), (Category: FABRIC), (Description: Ingressq encountered a device error that has exceeded its threshold value. Driver takes appropriate action to log and fix the error which may include a device reset.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-ARB_SERDES_0_FAIL_1 ### Response: (Severity: 1), (Category: FABRIC), (Description: Arbitration serdes link 0 failure on FIA 1.), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SL-7-INIT_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: This log indicates that Service Logger was not able to initialize. As result of this error, Service Logger will not log be able to log data in the log file.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-ERR_ASIC_MBE ### Response: (Severity: 3), (Category: FABRIC), (Description: Ingressq encountered a multiple bit error in the mentioned block. This error is an uncorrectable error. Driver takes appropriate action to log and fix the error which may include a device reset.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OIRD-7-MSG_ATTACH_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to attach handler for sync events.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-0-CARD_OVERTEMP_SHUTDOWN ### Response: (Severity: 0), (Category: PLATFORM), (Description: Card temperature has risen at or over shutdown threshold. Card shutdown commencing.), (Recommended Action: Verify the failure, give CLI: (admin)# show env --> particularly temperature and fan output (admin)# show env trace Card is put in IN-RESET state, use CLI: to bring card back into service, or a manual unplug / replug of the card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLARP_LITE_MAIN-3-DLL_OPEN_ERR ### Response: (Severity: 3), (Category: L2), (Description: 'Process failed in opening dll.' 'ISSU operation will continue without any error.'), (Recommended Action: 'ISSU manager will retry opening dll after sometime.' 'If the issue persists ' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMP-3-CONFIG_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Crypto Configuration (SAs/ACLs) failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-FAILED_CALL_PLATFORM_RELOAD_NODES_ALL ### Response: (Severity: 4), (Category: INSTALL), (Description: The Install Manager called the platform API to reload all nodes in order to complete the parallel install operation. The platform call failed, so the dSC is going to be reloaded directly which will trigger a router reload), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-UNKNOWN_BOARD ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the board type cannot be recognized, therefore, the node will not be able to boot up. This may be caused by an invalid eeprom content; or happens in a rare corner case which may recover after a board reset.), (Recommended Action: Two possibilities to this message. 1) The board boots up after resets : *None* 2) The board does not boot up after resets : Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-FSMTIMEOUTMDR_RESET ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is not able to boot up after a warm reload. If an MDR-mbi-hello is not recieved within a specified time limit, then the node will go to ENA-FAILURE.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSUDIR-1-OPERATION_PROC_ABORT_REQUEST ### Response: (Severity: 1), (Category: INSTALL), (Description: ISSU operation aborted due to the named process requesting an abort on the given node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The reason for this issu operation failure has to be analyzed. Collect 'show tech-support issu' and forward the logs to the TAC. In addition, 'show tech-support' should be gathered for the process which requested the abort where possible. These logs should also be forwarded to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-APIERR ### Response: (Severity: 3), (Category: ROUTING), (Description: A lower-level support function returned an unexpected status.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-TM_CLUSTER_PARITY ### Response: (Severity: 0), (Category: PLATFORM), (Description: A parity error interrupt), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP_NSR-3-MSG_PROCESSING_FAIL ### Response: (Severity: 3), (Category: IP), (Description: TCP was unable to process an SSO related message. This is likely a transient condition or an ignorable error.), (Recommended Action: The process may attempt to recover from this situation by retrying the operation. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-4-PAK_FROM_NETIO_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: CLNS was not able to process a packet from NetIO successfully and hence dropped the packet.), (Recommended Action: This message could be seen under low packet memory conditions and should recover once packet memory becomes available to CLNS. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_SYSMGR ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA encountered an error communicating with Sysmgr. The error message describes what operation has failed and why it failed. The most likely reason for this is a temporary initialization problem, but the error could also be caused by programming error.), (Recommended Action: In most cases, PPPoE MA will not be able to recover, so will shutdown. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.. *SUPPORT*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the nsf cisco command in IS-IS? ### Response: The nsf cisco command is used to enable Cisco-proprietary Non-Stop Forwarding (NSF) for IS-IS. NSF allows the router to continue forwarding traffic during a supervisor switchover or a software upgrade. It requires the router to maintain its forwarding table and to synchronize its database with neighboring routers after the switchover or upgrade. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_0_ERR3_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 0 ran into error-3 on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TEJAS_DRV-2-CRITICAL_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: The message is used to report TEJAS DRIVER critical errors.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ temperature greater than or equal to the high temperature warning threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-7-SHIP_INITFAIL ### Response: (Severity: 7), (Category: SERVICES), (Description: A failure occurred during the initialization of the debug statistics.), (Recommended Action: Debug statistics are used to debug cgn_ma in case of functionality issues. This will not impact CGN_MA in any form.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENV_AGT_DLL-3-MSG_EP_PWRSEQ_PROGRAM ### Response: (Severity: 3), (Category: PLATFORM), (Description: LDA sends this message to envagt to program the power sequencer of EP when it detects the EP power up failure.), (Recommended Action: Provide the following CLI to collect the LDA/env_agt trace: show controllers lda trace location (admin)# show env trace pwrseq) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP-6-INFO_DUPADDR ### Response: (Severity: 6), (Category: IP), (Description: A peer device is configured with the same interface IP address.), (Recommended Action: Change the interface IP address of one of the two devices.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-3-HOST_MODE_VIOLATION ### Response: (Severity: 3), (Category: L2), (Description: Only one auth client is expected in (Single/Multi) Host mode), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-5-PEER_STATE_CHANGE ### Response: (Severity: 5), (Category: OS), (Description: An PCE peer has changed state. This message appears only if the pce logging events peer-status command is configured for the PCE.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_IPV6_EA-3-CRITICAL ### Response: (Severity: 3), (Category: PLATFORM), (Description: DNX IP-EA, Critical error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSU-3-OLD_FIRMWARE ### Response: (Severity: 3), (Category: LIBRARY), (Description: The PSU has old firmware.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VCDMA-3-ERR_BAG_REG ### Response: (Severity: 3), (Category: PLATFORM), (Description: EDM Bags are used to share information between components using sysdb. This Error indicates that bag registration failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key components of an RPL policy in IOS XR? ### Response: The key components are: 1) Route policy: The top-level construct that defines the policy. 2) Prefix set: Defines a set of prefixes for matching the route's Network Layer Reachability Information (NLRI). 3) AS path set: Defines a set of AS path regular expressions for matching the route's AS path attribute. 4) Community set: Defines a set of BGP communities for matching or setting the route's community attribute. 5) Policy statement: Defines a sequence of actions to take if the route matches the specified conditions. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN-4-STATS_CLEAR_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The SPAN MA was unable to clear statistics for the specified source interface. The SPAN MA would normally clear statistics at the point at which a source interface is removed from a session. Traffic replication will continue to operate as normal, but statistics relating to traffic replicated while the interface was in the session it has just been removed from will persist until they are manually cleared.), (Recommended Action: The source interface counters can be cleared by running 'clear monitor-session counters'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-PROCESS_EXHAUSTED ### Response: (Severity: 3), (Category: OS), (Description: Exhausted all instances of placeable process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC_CTRL-6-RACK_STATE ### Response: (Severity: 6), (Category: PLATFORM), (Description: One rack of the cluster system has entered or exited the cluster. Up state is normal for a rack in the cluster. Down could indicate a rack level reboot, or a connectivity issue between the racks.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IEP-3-DAEMON_ERR_EVM_CREATE ### Response: (Severity: 3), (Category: IP), (Description: An error occurred while creating the process event manager.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-1-AUTO_RECOVERY ### Response: (Severity: 1), (Category: PLATFORM), (Description: This error message indicates that the driver process is unresponsive. All retries have been exhausted. Auto-recovery action involves either restart of the process or reload of the node which may lead to some traffic loss. For debugging this error, a voluntary running core file will be generated before the auto-recovery action.), (Recommended Action: Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-STBY_INIT_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to initialize acctd on standby node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FLOWTRAP-4-BAD_ACTOR_INTF_CLEARED ### Response: (Severity: 4), (Category: OS), (Description: An interface that was previously flagged by the punt flow trap has been removed from the 'penalty box.'), (Recommended Action: No action necessary. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel mesh affinity feature? ### Response: The MPLS TE auto-tunnel mesh affinity feature allows auto-tunnel mesh tunnels to select or avoid links for the mesh paths based on configured affinity attributes. This provides more control over the mesh path selection compared to the default behavior of using the TE metric. Affinities allow mesh paths to be optimized for specific requirements. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_OPM-4-CANNOT_SYNC ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: An ICCP redundancy group which is being used for satellite multi-chassis redundancy could not be synchronized due to the error stated.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-ERR_EVM_TM_LEAF_NEW ### Response: (Severity: 7), (Category: OS), (Description: An internal error was detected when trying to create a timer tree leaf object.), (Recommended Action: When this issue happens, it will trigger an automatic restart. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls ldp nsr' command in Cisco IOS XR? ### Response: The 'mpls ldp nsr' command enables the LDP Non-Stop Routing (NSR) feature. LDP NSR provides the ability to maintain LDP bindings and continue forwarding MPLS traffic during an RP switchover. It ensures minimal traffic loss during RP failover by synchronizing the LDP state between the active and standby RPs. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-3-FPD_IMG_CORRUPTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: An FPD image in non-volatile memory is corrupted or missing. Each FPD has 2 images stored in non-volatile memory, one is field upgradable version; the 'B' version. The other is the backup version; the 'A' version. If a B version FPD image has gone bad, it can be recovered by following the recommended_action. If the A version has gone bad, the board must be replaced.), (Recommended Action: Use the following command to find out which FPD image is bad/missing: 'show log | inc PFM | inc FPD'; If it is the B version (the upgradable version), then reprogram the image using the upgrade command: 'admin' 'upgrade hw fpd force location ' If any A version is bad, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCFIND-7-SYSDB_BIND ### Response: (Severity: 7), (Category: OS), (Description: Procfind was unable to bind to the SysDB server, and therefore failed to initialize.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-RCC_NO_TABLE ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred that prevented the FIB from completing the route check.), (Recommended Action: Try restarting the FIB process to see if the route gets programmed again. LC OIR or clear route * can be tried as well. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBCORE-7-SYSDB_INFO ### Response: (Severity: 7), (Category: SNMP), (Description: This is an information system log providing sysdb information. It will provide you sysdb interface name and sonet path structure interface name.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_LTRACE_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An unrecoverable error occurred at system initialization time.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlea-4-EVENT_BLOCK ### Response: (Severity: 4), (Category: L2), (Description: The VLAN EA process encountered an error while listening for events. The process will automatically restart and retry.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-6-USER_RESET ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that the user has requested to reload the node.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_NETIO-4-ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during an initialization operation in the PPP NetIO DLL. If this occured during an upgrade operation then it will cause the NetIO process to reload. Otherwise this will cause the capsulation to be unloaded, and an error returned to the user. One possible reason for the error is a low memory condition, particularly if the failure was in allocating trace buffers.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How are configuration failures handled during router startup in IOS XR? ### Response: During router startup, if there are configuration failures, IOS XR boots with the last known good configuration instead of the latest changes. This ensures that the system comes up in a consistent state even if recent configuration changes caused issues. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEXMGR-3-INTR_MASKED ### Response: (Severity: 3), (Category: PLATFORM), (Description: PCIE interrupts masked due to large errors), (Recommended Action: This error is a momentary error and software should be able to correct it. No action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_RESYNC_TIMEOUT ### Response: (Severity: 3), (Category: FABRIC), (Description: When FSDB starts up it attempts to resynchronise the state with all current entities. This message indicates that one or more of these entities has not responded within the timeout period. This could lead to FSDB having an inconsistent view of the fabric, and can potentially cause traffic loss.), (Recommended Action: Restarting FSDB process on any racks suffering from traffic loss may help, if not, restart FSDBs on all racks might resolve the issue. 'admin process restart fsdb_server location ' Since 'restart process' is a disruptive operation and all the previous state is lost, all the logs for the commands mentioned in required_info should be saved. If problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-3-SPA_REMOVE ### Response: (Severity: 3), (Category: L2), (Description: This message indicates an error on spa bus for which internal recovery action (i.e., SPA reset) has been initiated.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-3-ERR_USAGE ### Response: (Severity: 3), (Category: IP), (Description: Usage error.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ERRDIS-4-PROC_READY_FAILED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: This is a fatal error which will slow down system intialization following boot or a failover event. The process will restart in an attempt to clear the error.), (Recommended Action: If the error message indicates a potential out of memory condition Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Otherwise, this indicates a problem with the sysmgr infra, Gather 'show tech-support sysmgr'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-TX_CH_LO_PWR ### Response: (Severity: 3), (Category: FABRIC), (Description: The POD detects a low power on a channel. The channel may not be functioning properly, and can cause cell drops, or corruption in the downstream. This is a precursor to the Tx LOS.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the main components of the Cisco IOS XR microkernel architecture? ### Response: The main components of the Cisco IOS XR microkernel architecture are\n- Microkernel: Provides minimal OS services like scheduling, memory management, and IPC\n- OS processes: Includes process manager, IPC services, and device drivers\n- Restartable processes: Includes routing protocols, management, forwarding processes\n- IPC message passing bus: Enables communication between microkernel and processes\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-SHUTDOWN_DISABLED ### Response: (Severity: 4), (Category: PLATFORM), (Description: NP shutdown action is disabled. The network processor is in an unknown state and may not be operational.), (Recommended Action: Unless disabling NP shutdown was intentional, NP shutdown must always be enabled on a production node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTT0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure RSVP interface priorities in Cisco IOS XR? ### Response: To configure RSVP interface priorities, use the 'rsvp interface' command followed by 'priority' in interface configuration mode. RP/0/RSP0/CPU0:router(config)#rsvp interface GigabitEthernet0/0/0/0 RP/0/RSP0/CPU0:router(config-rsvp-if)#priority 3 3 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_BAT_FAIL_A ### Response: (Severity: 2), (Category: PLATFORM), (Description: The CPT 50 Panel Battery Failure A (SAT_BAT_FAIL_A) alarm is raised when the battery A fails. This could be because the battery is removed or is not operational.), (Recommended Action: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-3-LTRACE_OPEN_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Due to an error in the ltrace initialization routines, the init failed. This may be due to other problems on the system (is ltrace running?).), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-CHUNKCREATEFAIL ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: Could not allocate a chunk of memory for the packet headers.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBCORE-3-PM_DATA_FAILED ### Response: (Severity: 3), (Category: SNMP), (Description: A problem occurred while fetching data from pmengine for port and path. first %s - Determine PM_DATA failed at port or path second %s - Reason of failure), (Recommended Action: Check for memory usage, this is a very corner case and collect required info as well.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-BA_BAD_SEQ_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The sequence number in the received PBU is not the one that's expected.), (Recommended Action: Note the NAI of the MN from the error message. Clear the binding using the following command. Check if the error goes away after receiving a new PBU after the binding is cleared. clear ipv6 mobile pmipv6 lma binding nai If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cds_proxy-3-MEMORY ### Response: (Severity: 3), (Category: OS), (Description: The server has failed to acquire the required amount of memory.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP MED attribute? ### Response: The multi-exit discriminator (MED) is an optional attribute that suggests to an external AS the preferred path into the local AS when there are multiple entry points. A lower MED is preferred. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-NOTIFY_UNREGISTER_FAILED ### Response: (Severity: 7), (Category: OS), (Description: A application requested database un-notification could not be removed from the QSM notification database. An error will be returned to the client process.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_5_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_5 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-MISSING_HNP_OPTION ### Response: (Severity: 3), (Category: IP), (Description: HNP option is not received in the PBU. This happens if the service configured for the MN on the LMA is IPv6 or Dual and that on the MAG is not matching.), (Recommended Action: Note the CoA address, IMSI (if available) and NAI from the error message. Run the following command on the MAG that corresponds to the above CoA address or IMSI. Copy the error message exactly as it appears on the console or in the system log. Issue the show running-config | section mobile command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show running-config | section mobile output, call your Cisco technical support representative and provide the representative with the gathered information. Note the service type of the MN or Logical-MN (corresponding to the NAI noted above) under domain configuration and Logical-MN configuration. Run the following command on the LMA. Copy the error message exactly as it appears on the console or in the system log. Issue the show running-config ipv6 mobile command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show running-config ipv6 mobile output, call your Cisco technical support representative and provide the representative with the gathered information. Note the service type of the MN or Logical-MN (corresponding to the NAI noted above) under domain configuration. If the service type configired on the MAG and the LMA is not the same, reconfigure matching service type on the MAG and/or the LMA. If the issue persists, do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_SSUB ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from SSUB.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_UV-3-SYSMGR ### Response: (Severity: 3), (Category: L2), (Description: The process was initialized successfully but was unable to inform System Manager of the success. This should not occur more than once as the process should restart itself.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-TX_ALARM_TPDV ### Response: (Severity: 3), (Category: PLATFORM), (Description: In T1 mode TPDV alarm is raised when the transmit data stream does not meet ANSI T1.403 requirements for transmit pulse density.), (Recommended Action: Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-MAC_MOBILITY_SEQ_NUM_WRAPPED ### Response: (Severity: 3), (Category: L2), (Description: EVPN MAC mobility sequence number wrapped indicator.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-6-REFBW_CHG ### Response: (Severity: 6), (Category: ROUTING), (Description: Informational message reminding the user that reference bandwidth should be consistent across all routers in the area.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: S2681-3-STATUS_MUTEX_LOCK_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The S2681 UART driver was unable to lock the status variable for the interrupt thread.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-OPEN_OR_DUP_DEVICE ### Response: (Severity: 3), (Category: MGBL), (Description: Failed to open or duplicate the device file that exec requires for read/write operations.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-EBS_CPU_DATA_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: EBS to CPU packet data single bit error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FTI-3-XML_ERR_MSG ### Response: (Severity: 3), (Category: INFRA), (Description: XML error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-PTHREAD_MUTEX_UNLOCK ### Response: (Severity: 3), (Category: MGBL), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-6-INFO ### Response: (Severity: 6), (Category: FABRIC), (Description: Just for information. Message is self explanatory.), (Recommended Action: No user action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_ENA-3-CRYPTO_DEACT ### Response: (Severity: 3), (Category: MGBL), (Description: The crypto pie is deactived or removed while http server is running in ssl mode.), (Recommended Action: Unconfigure http server or configure it to run in non-ssl) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-3-KERNEL ### Response: (Severity: 3), (Category: MGBL), (Description: The RS232 driver has made a kernel call which is failing; it cannot proceed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_MEAS-5-RSVP_TE_TUNNEL_BURST_INTERVAL_STRETCHING_INACTIVE ### Response: (Severity: 5), (Category: ROUTING), (Description: The condition triggering the RSVP_TE_TUNNEL_BURST_INTERVAL_STRECTHING_ACTIVE syslog has been cleared. RSVP-TE Tunnel delay measurement sessions now run using their configured burst interval.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-EVENT_FAIL ### Response: (Severity: 4), (Category: LICENSE), (Description: The license manager encountered an error condition while processing an event. Check the error string to determine what has happened.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CETHHA-2-CRITICAL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Hardware error on CPU control ethernet port.), (Recommended Action: Remove/Replace the RP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-7-DEBUG_MSG ### Response: (Severity: 7), (Category: L2), (Description: This is a debug message in the PSE Driver to indicate an operation or condition.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-BM_DEAD_NODE_RECOVERY_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: We were unable to recovery from dead node state. We attempted 3 times, but dead node clearning recovery is failing.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC18 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_DATALIST ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCRIPT_MGMT-7-DEBUG ### Response: (Severity: 7), (Category: OS), (Description: Debugging messages.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-INTERNAL_STATE_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured due to inconsistent internal state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp statistics peer command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp statistics peer output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging processes msdp error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging processes msdp error output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_6_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-3-FWC_INIT ### Response: (Severity: 3), (Category: SECURITY), (Description: A failure occurred during the process startup of the firewall controller. This is most likely caused by a failure of some piece of infrastructure used by the firewall controller. The error message may give an indication of the root cause of the failure.), (Recommended Action: The process will be restarted by the System Manager - no further action is necessary. If the problem occurs repeatedly, copy the error message and gather the other necessary information, and call you Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_SYSMGR_MON_LIB-3-SYSMGR_HB_SEND_FAIL ### Response: (Severity: 3), (Category: HA), (Description: Vm-monitor is not able send heartbeat message to sysmgr.), (Recommended Action: This indicates an problem with communication with sysmgr process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-3-MUTEX_REVIVED ### Response: (Severity: 3), (Category: L2), (Description: The PIRD database uses a number of shared-memory locks to protect against concurrent access by clients. A client process died whilst holding one of these locks, and it was forcibly recovered. This may have resulted in an internal inconsistency which could cause other problems.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-DATAARRAYLENGTH ### Response: (Severity: 4), (Category: MGBL), (Description: The number of elements entered for a data array does not match the expected value.), (Recommended Action: Use the classinfo command to get more information about the naming or value information of a class. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EDRM_DLL-3-CACHE_REQ ### Response: (Severity: 3), (Category: L2), (Description: Caching request can not be serviced due to the indicated reason.), (Recommended Action: None. System will continue to function without caching.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-SHMWIN_INIT_FAILURE ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to initialize shared memory window), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_TUNNEL_EA-3-UPDATE_ERR2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the CRS platform specific code software to indicate problem that happened during an update event. %s - indicates the reason for the failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB-7-ERR_RRW_UNLOCK ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server failed to release rrw lock to the request record area in shared memory. This is a fatal error, the process will automatically restart.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFDIAGBASE-3-CONN_FAIL ### Response: (Severity: 3), (Category: DIAG), (Description: Diagnostics software has received a packet from a client, but the client is not connected to the server. Another component may have restarted causing the connection to be broken. This is not a service impacting error.), (Recommended Action: Check the log ('show logging') to see if any processes have restarted or to determine if there are any other related error messages. Also, please check Bug Navigator ( https://tools.cisco.com/bugsearch?referring_site=btk ) to search for any bugs in this area or of any processes found to have restarted. Copy the error message exactly as it appears on the screen and gather any relevant information about the circumstances. Also collect the information from the 'show logging' and 'show tech diagnostics' commands. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_16 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-BADLSA ### Response: (Severity: 4), (Category: ROUTING), (Description: The router received an invalid LSA. The cause is either memory corruption or unexpected behavior on a router.), (Recommended Action: Check both the sending and receiving routers for memory corruption. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_14_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_DISP_ERROR_LANE_INDICATE_14 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_0_ERR1_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 0 ran into error-1 on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-FIT_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver cannot initialize the FIT library. User will not be able to induce errors via FIT tool.), (Recommended Action: Collect all the event logs and 'sh controller fabric trace driver all location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_ATOMIC_RING_OP ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occurred while performing an atomic ring operation. This may be due to resource starvation or an internal software programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG_HIST_UPDATE-3-SYSDB_SET ### Response: (Severity: 3), (Category: MGBL), (Description: Internal error), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-7-CBC_PRE_RESET_NOTIFICATION ### Response: (Severity: 7), (Category: PLATFORM), (Description: Informational log only), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-4-INV_PKT_FIELD ### Response: (Severity: 4), (Category: L2), (Description: A packet containing an invalid field was detected in a batch passed to the PIRD plug-in or fabric header library.), (Recommended Action: If any problems are seen, they may be rectified by restarting the affected process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEATURE_LPTS-3-UNALLOCATED_FREE ### Response: (Severity: 3), (Category: FABRIC), (Description: A software error occurred, when the PA attempted to free unknown FGID), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MMAP_PEER-3-SHM_OPEN ### Response: (Severity: 3), (Category: OS), (Description: The open() failed in mmap_peer_local.), (Recommended Action: Copy the message exactly as it appears, and report it your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-7-TREE_OP_ERR ### Response: (Severity: 7), (Category: ROUTING), (Description: A tree operation failed.), (Recommended Action: This message is informational.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_BAD_CIRC_TYPE ### Response: (Severity: 4), (Category: ROUTING), (Description: Bad circuit type (CIRCUIT-TYPE) from SOURCE_IF. This system received an IS-IS hello with a header reporting an invalid circuit type of CIRCUIT-TYPE. This is the result of a mal-formed packet rather than a configuration error. The packet has been ignored.), (Recommended Action: Identify the source of the offending packet and correct it. If the message recurs 'debug isis packet-errors detail' may be used to provide a dump of the problematic PDU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-PTHREAD_MUTEX_LOCK ### Response: (Severity: 3), (Category: MGBL), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: FIA-driver Event Manager create error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-6-INFO_SHOW ### Response: (Severity: 6), (Category: PLATFORM), (Description: PLATFORM FIB, Information), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-5-SATELLITE_FABRIC_MESSAGE_RECEIVED ### Response: (Severity: 5), (Category: L2), (Description: A notification message has been received from a Satellite regarding the operational status of CFM on Satellite fabric links.), (Recommended Action: Depending on the content of the notification message, it may be necessary to adjust the CFM Satellite fabric link configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-3-IMDR_EOC_ERROR ### Response: (Severity: 3), (Category: FABRIC), (Description: A problem was encountered while trying initialize with the IMDR EOC library. This library is used during IMDR to keep track of the client requests to Ingressq and to determine when to notify the imdr process that all client requests have been received. If the ISSU/IMDR upgrade is in progress, the upgrade may not complete sucessfully. If the ISSU/ IMDR action is not in progress, the initialization will not complete until such time as a IMDR EOC library initialization completes sucessfully.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_FT_FAN_AIRFLOW_MISMATCH ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when fan trays of different airflow (suction or exhaust) are present on satellite.), (Recommended Action: Please use fan trays with same air flow type on satellite. i.e. either suction or exhaust.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-3-ERROR_MSG ### Response: (Severity: 3), (Category: L2), (Description: This is a debug message in the NPU Driver to indicate an operation or condition.), (Recommended Action: Collect the console logs 'sh logging' Traceback data. npu_driver_driver core file, if generated. 'show asic-errors all location <>' 'asic-errors dump pse location <>' 'show asic-errors pse trace all location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-USING_OLD_RTRID ### Response: (Severity: 4), (Category: ROUTING), (Description: OSPFv3 failed while attempting to allocate a router ID from the IPv4 address of one of its interfaces due to an unexpected internal problem.), (Recommended Action: Use 'clear ospfv3 process' to force another attempt to find a valid router ID. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-5-INVALID_PUNT_TYPE ### Response: (Severity: 5), (Category: OS), (Description: The punt packet type information is not valid.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPMgr-3-CONSTRUCT_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Error in fault profile mgr construction failure.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFLX_LIB_EA-3-SSC_SEND_SRV ### Response: (Severity: 3), (Category: SERVICES), (Description: A problem was encountered while trying to send a single message to the Service Director. The Service Director may not be up to date with the state of this services on this node, so the associated InterFlex interfaces located on this node may fail to forward packets.), (Recommended Action: It may help to restart the InterFlex EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-3-DEBUG_REGISTER_FAIL ### Response: (Severity: 3), (Category: HA), (Description: An internal error was detected when registering with the debug library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-3-BPDU_UNREADABLE ### Response: (Severity: 3), (Category: L2), (Description: STP received a BPDU but was unable to read the contents via a call to the Ethernet Packet Infrastructure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGEDM-3-UNREGISTER ### Response: (Severity: 3), (Category: MGBL), (Description: Failing to unregister the edm.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-6-DIAG_STOPPED ### Response: (Severity: 6), (Category: DIAG), (Description: Diagnostic test has stopped.), (Recommended Action: Nothing. This is an informational message stating that diagnostic testing has been stopped. If you want the test to run to completion, rerun the test.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRD-3-NOMEM ### Response: (Severity: 3), (Category: SERVICES), (Description: There are insufficient resources to perform some action. The error message contains more details about what action failed.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Once the memory conditions have been improved, restart the Service Role Daemon process to allow it to resynchronise with its clients.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHEMA-6-VERSIONCHANGE ### Response: (Severity: 6), (Category: MGBL), (Description: The version of some part(s) of the schema which are running on the router have changed - this is an informational message to let any users of the schema know of the change.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_PA_INTR_UCFF_UDR_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_PA_INTR_UCFF_UDR_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_EVC_OPEN ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA failed to open a connection to an essential service during initialization. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-EXEC ### Response: (Severity: 3), (Category: MGBL), (Description: The Exec launcher failed to exec 'exec'. This could be due to an error picking up the load path from install manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-BAD_MSGLEN ### Response: (Severity: 7), (Category: HA), (Description: The source message length is less than the message length. This is a situation which should never happen.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-PDMA_QUEUE_RX_STOP ### Response: (Severity: 3), (Category: PLATFORM), (Description: Indicated device stop process the incoming packets in the receiving queue, while there is still packets in the pdma queue. %s: device name %d: queue number %s: client name), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLUSTER_UPGRADE-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message from the Cluster Upgrade Engine), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-6-CNET_RELAY_OP_NCK ### Response: (Severity: 6), (Category: PLATFORM), (Description: attach: LC disconnects the connection. %s- Message description. %d- Reason for the failure.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-STBY_INIT_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to initialize locald on standby node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-CONFIGFAIL ### Response: (Severity: 3), (Category: SNMP), (Description: Failed to perform the indicated configuration operation. This could be due to a low memory condition, an unsane configuration, or an internal software error. Failed in Host config: Received a good tuple for the snmp-server host CLI command, but could not configure it. This is likely due to lack of memory, which may be a transient condition, or may be due to SNMP supporting too many MIBS with large amounts of data. Try this command again after a few minutes. If it continues to fail, you may wish to undo some SNMP configurations and then retry the command.), (Recommended Action: Examine the configuration and ensure that it is sane. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *SH_CMD config*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_HQ_OFLOW_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue overflow error on XAUI 1 HQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-4-MASA_AUTH_TOKEN_PARSE_ERROR ### Response: (Severity: 4), (Category: SERVICES), (Description: 'Encountered error while parsing the authentication token ' 'response string from MASA server'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different SysDB planes and what is their purpose? ### Response: SysDB is organized into different planes based on the scope and persistence of data\n- Admin plane: Contains config and state data that is available across the system. It is persistent between reloads.\n- Shared plane: Contains config and state specific to a card type (RP, LC) but shared between cards. It is persistent.\n- Local plane: Contains non-persistent state, statistics, and diagnostic data specific to a node.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-1-ERR_INIT ### Response: (Severity: 1), (Category: FABRIC), (Description: The Ingressq driver failed to initialize the device resulting in the restart of the Ingressq driver process.), (Recommended Action: Collect all the event logs and the output of the following command executed from the CLI of the active RP: 'show process ingressq' Also, collect the fabric snapshot: 'show fabric-snapshot file <> loc <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RS232-4-TEMPLATE_APPLY_ERROR ### Response: (Severity: 4), (Category: MGBL), (Description: The RS232 DLL tried to apply a template to a TTY but failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-2-CPLD_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: The Fabric PLD power fault alarm was encountered), (Recommended Action: A power fault has occurred.If the fault has occurred, node will be shutdown. Please collect logs mentioned in required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_VCM-3-IDB ### Response: (Severity: 3), (Category: L2), (Description: Unexpected error on Interface Descriptor Block), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-ERR_CREATE_SERVER_ENTRY ### Response: (Severity: 3), (Category: SECURITY), (Description: A configuration error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-7-script_spawn ### Response: (Severity: 7), (Category: OS), (Description: Start/Complete spawning a script), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-4-CHECKPOINT_REG_FAILED ### Response: (Severity: 4), (Category: INFRA), (Description: On going primary active, checkpoint table registration failed. The protocol process has been restarted to attempt to recover.), (Recommended Action: If the protocol process starts up successfully, then no further action is required. If repeated restarts are seen, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-BAD_INSTDB_FORMAT ### Response: (Severity: 7), (Category: INSTALL), (Description: INSTDB file is in an obsolete format or is unknown.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMONMIB-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: SNMP), (Description: The MIB had trouble allocating memory.), (Recommended Action: Please collect 'show memory summary', 'top' and 'show tech-support performance-traffic' and contact Cisco technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-5-EVAL_START ### Response: (Severity: 5), (Category: LICENSE), (Description: Either customer allocate entitlement prior to registration or customer registration has expired. The device is now de-registered and is in evaluation mode.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-CHILD_TERMINATED ### Response: (Severity: 3), (Category: MGBL), (Description: A child process received a signal and terminated abnormally.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TRANSPORTAIPC-3-DEBUG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to initialize or shutdown the debug module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_HEAP-7-BAD_NCTDELETE ### Response: (Severity: 7), (Category: HA), (Description: Bad NCT record is being freed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-3-ERR_INVALID_CARD_TYPE ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric cards bitmap capacity cannot be determined because platform_node_get_card_type returned an unrecognized card type.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-2-ASICS_NOT_RELEASED_FROM_RESET ### Response: (Severity: 2), (Category: PLATFORM), (Description: ASICS not out of reset.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is Virtual Private LAN Service (VPLS) and how is it configured in Cisco IOS XR? ### Response: VPLS is a multipoint-to-multipoint L2VPN service that provides Ethernet-based Layer 2 connectivity between multiple customer sites, emulating a LAN segment. It is configured using the 'l2vpn' configuration mode. The 'bridge group' command is used to define a VPLS instance and the 'bridge-domain' command is used to specify the VPLS domain. The 'vfi' command is used to define the virtual forwarding instance and the 'neighbor' command is used to specify the remote PE routers participating in the VPLS service. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-4-BRM_INVALID_INPUT ### Response: (Severity: 4), (Category: FABRIC), (Description: There might be a fabric disconnect in the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-WARN_CID_SES_THRESHOLD_EXCEED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions on a particular Circuit ID has exceeded the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBUS-6-HBM_LANE_REPAIR_SUCCESS ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an message in the SBUS Driver to indicate that the lane repair operation has succeded on the specified HBM memory), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENTITYMIB-3-INIT_ERROR ### Response: (Severity: 3), (Category: SNMP), (Description: A failure occured during the initialization of the process.), (Recommended Action: Restart mibd_entity) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-BAD_MSG_TYPE ### Response: (Severity: 3), (Category: OS), (Description: 'Message type of the GSP message is corrupted.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PM-7-ERR_SYSDB ### Response: (Severity: 7), (Category: MGBL), (Description: An error has occurred while doing a sysdb operation. See the message text for error details.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_HEAP-7-NCT_BIGNEW ### Response: (Severity: 7), (Category: HA), (Description: Higher layers of heap are requesting a size for a variable-size record that is too large.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TEMP_OUT_OF_RANGE ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_3_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_BRIDGING-7-DEBUG_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB BRIDGING component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-ALARM_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that shelfmgr cannot initialize envirnoment for setting LED display or alpha display.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-2-BOARD_REV_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: LC CPU controller driver version is not compatible with the current Board.), (Recommended Action: Reset the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-3-FIELD_PRESEL_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: DPA failed to create field-group on this NPU.), (Recommended Action: Verify your hw-module configuration. Otherwise, collect show-tech and contact cisco support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_EDM-3-SYSDB_BIND_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: The process failed to connect to SysDB while starting the indicated subsystem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CBQOSMIB-4-ERR_BLOCK ### Response: (Severity: 4), (Category: SNMP), (Description: There was an issue in retrieving stats for one of the interfaces. This could happen if one of the participating processes (qos_ma, qos_ma_ea, qos_ma_ea, ifmgr, etc) was busy and could not process the stats request. The interface in question will not be polled for the next 30 seconds to allow recovery from the problem state.), (Recommended Action: Please collect the following tech-support to find the cause of the issue: * show tech-support qos pi * show tech-support pfi * show snmp trace cbqosmib) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTF_EA-3-POLICE_GRAN ### Response: (Severity: 3), (Category: PLATFORM), (Description: The LC needs to be reloaded, or the policy has to be reapplied for the configured qos police granularity to be effective.), (Recommended Action: Exit the Config-terminal. Reload the Linecard using 'hw-module location reload' option. Reapply the MQC policy on all interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_4_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-EA_MIPC_NTFN_ACK_FAILURE ### Response: (Severity: 3), (Category: QOS), (Description: QoS EA encountered an error while ACKing to an MIPC event), (Recommended Action: Try restarting QoS EA process get the JID by 'show processes qos-ea location <>' 'process restart location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PMLIB-2-ERROR_INIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Platform Manager client library encountered an initialization error A reason text will be supplied to describe the error.), (Recommended Action: Check if the process is blocked using- 'show process blocked location ' if the pm process is blocked restart the process using- 'process restart location ' to recover from this error. Please collect output for 'show log location ' and 'show memory summary location ' from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_7_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power less than or equal to the low Tx power warning threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE2_LANE_CRC_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE2_LANE_CRC_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-3-ERR_LIST_FAIL ### Response: (Severity: 3), (Category: SYSDB), (Description: This message indicates the error while processing the reply message by SysDB.), (Recommended Action: Try applying the configuration of this process/feature again. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_WL_OUT_OF_RANGE ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-4-EAD_INVALID_SRV6_SERVICE_TYPE ### Response: (Severity: 4), (Category: L2), (Description: SRv6 Service TLV contains the type of SRv6 Service. Only type-6, which encodes service SID information for SRv6 based L2 services is supported. This corresponds to the equivalent functionality provided by an MPLS Label for EVPN Route-Types as defined in RFC7432.), (Recommended Action: Check if other devices in the network support different SRv6 Service types or check the Service type in packet captures. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHOWCMD-3-CLI_ERROR ### Response: (Severity: 3), (Category: SNMP), (Description: 'The failure pertains to show commands in snmp.' 'This does not indicate feature failures or issues'), (Recommended Action: 'This log does not indicate a system impact.' 'all show snmp CLI's for debugging purpose only' 'Recommend customer to re-try the command.' 'If there is no output, reconfigure the snmp settings and re-try') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-FAN_CLEAR ### Response: (Severity: 2), (Category: PLATFORM), (Description: The indicated fan has measured RPM returning to operating level.), (Recommended Action: None required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-DEVICE_DISCOVERY_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter device not discovered on pcie), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-3-FABRIC_LINK_DOWN ### Response: (Severity: 3), (Category: FABRIC), (Description: One or more fabric links went down from above location.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-SYSDB_API_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: SysDB operation error.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_MIXED_AC_DC_POWER_MODULE ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when power modules present on the satellite are of mixed type, i.e. AC and DC.), (Recommended Action: Please use either all AC or all DC power modules in the satellite) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_IPV4_EA-3-ERROR3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: DNX IPV4-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_SHMEM_HDR ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal Error: Shared memory header corrupted.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-PORT_NUM_CONFLICT ### Response: (Severity: 4), (Category: L2), (Description: A PTP port number has been allocated to more than one interface.), (Recommended Action: Remove and re-apply PTP configuration for the interfaces in question, in order to re-allocate port numbers for these interfaces. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_HEAP-7-CORRUPTION ### Response: (Severity: 7), (Category: HA), (Description: The process crashed during checkpoint heap modification, resulting in an unrecoverable heap. Process will be started from an empty heap.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-3-NOLOCK_TOPOLOGY_ACCESS ### Response: (Severity: 3), (Category: OS), (Description: An attempt to either read or modify the topology was blocked because no lock was acquired prior to the attempt, which could result in data corruption. The SR-TE process may now be in an inconsistent state with the rest of the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The xtc_agent process may be restarted in order to recover from this situation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different MPLS TE FRR protection modes? ### Response: The different MPLS TE FRR protection modes are\n- Link protection: Protects against link failure. Backup tunnel is routed around the protected link.\n- Node protection: Protects against node failure. Backup tunnel avoids the protected node.\n- Best-effort protection: Tries to protect against both link and node failure, but does not guarantee it.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-2-LOW_LASER_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected an SFP laser bias less than or equal to the low laser bias alarm threshold. The SFP is the pluggable optics on the line cards. The laser bias threshold values are read from the SFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does IOS XR handle configuration during router startup? ### Response: During router startup, IOS XR loads the committed configuration from the Configuration File System (CFS). If there are no configuration inconsistencies or failures, the router starts with the committed configuration. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_7 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port 7.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port 7 interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_GTRIE-3-ERR_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the ASR9K platform FIB specific code software to indicate anomolies that are not FATAL. This error is most likely caused by a temporary situation, so is unlikely to re-occur.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlan_netio-4-DEBUG_INIT_ERROR ### Response: (Severity: 4), (Category: L2), (Description: The VLAN NetIO component encoutered an error during debug initialization. This is likely to cause VLAN interface setup to fail.), (Recommended Action: If this error occurred as a result of applying configuration, try removing and reapplying the configuration. If this does not work, it may be necessary to reload the affected linecard. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFL_PD-3-FORMAT_DEVICE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This debug message indicates that format device failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. .) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-3-PLIM_HEARTBEAT_ERR ### Response: (Severity: 3), (Category: L2), (Description: The IPC communication between local CPU and host in the specified slot indicated in the message is not functional. If the problem persists the SPA will be reloaded to recover from the failure.), (Recommended Action: If the problem persists, try to reseat the SPA. If reseating does not help, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the information you have gathered.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_ALLOC-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID allocator was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPP-4-LPTS_WARNING ### Response: (Severity: 4), (Category: SECURITY), (Description: When the MPP (Management Plane Protection) tries to change the LPTS (Local Packet Transport services - used to deliver the locally destined packet to the correct node on the router) filters for a interface, unexpected scenario is hit.), (Recommended Action: Check if the interface exists. If the interface does not exist, this warning can be ignored. Else the command 'show tech-support lpts' can be issued to get any possible cause, if this message keeps recurring.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-FILE_ACCESS_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The given file could not be accessed due to reasons specified. Possible failures are lack of read/write permissions.), (Recommended Action: Check if the file being requested exists and has the correct read-write permissions.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_TX_FIFO_OFLOW_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI interface to NPU-0 reported tx fifo overflow on bridge instance - 0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected an CPAK temperature less than or equal to the low temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CPAK with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-4-LSP_OOR_GREEN_NORMAL_OPERATION ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-4-CDR_NOT_READY ### Response: (Severity: 4), (Category: FABRIC), (Description: CDR_READY status from CPLD indicates that egress CDR is not ready for access even after waiting for 200ms.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-SD_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: An SD related operation failed.), (Recommended Action: This is a serious error and will prevent the system from functioning properly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-FSDB_RESPONSE_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: Fia_driver response is not encoded becuase of bufsize is too small.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-6-MPLS_SROPT_CRIT_RECOVER ### Response: (Severity: 6), (Category: ROUTING), (Description: In lspnh update, SR-OPT criteria that was failing, has now been met/recovered. This is just for information>), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-MIB_GROUP_TREE_ERR ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-WAVL_INIT ### Response: (Severity: 4), (Category: L2), (Description: ELMI encountered an unexpected error which prevents it from functioning. This error may be caused by low memory resources. The process will abort and be restarted in an attempt to recover.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_IDB_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Failed while initializing IDB library.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSMGR-3-ALREADY_CALLED ### Response: (Severity: 3), (Category: OS), (Description: The specified API has already been called.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_HFR-7-INFO_SHM ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered a change in the shared memory region parameter.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-MFI_ERR_NON_FATAL ### Response: (Severity: 3), (Category: ROUTING), (Description: A software error occured while processing something from or to LSD. The error is unexpected but not fatal and ISIS will retry), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-INTERNAL ### Response: (Severity: 3), (Category: MGBL), (Description: An unexpected internal error occurred in the tacacsd.), (Recommended Action: Copy the error message and trace exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE7_LANE_CRC_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE7_LANE_CRC_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-3-BACKUP_PARTITION ### Response: (Severity: 3), (Category: PLATFORM), (Description: The FPGA has loaded from backup partition.), (Recommended Action: Upgrade FPGA using CLI command in admin mode -upgrade hw-module fpd <> If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFD_HELPER-0-INIT_FAILURE ### Response: (Severity: 0), (Category: MGBL), (Description: An error was encountered while initializing one of the critical modules of the confd_helper. Without proper initialization of this module, confd helpder can not operate properly. Initialization will be retried.), (Recommended Action: ConfD helper is a critical component and must be operational in order to configure the router. If the same error is seen more than 5 times, contact Cisco TAC support because a reboot of the node may be required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-REPLICATOR_OOS ### Response: (Severity: 4), (Category: SYSDB), (Description: The SysDB replicator module has been informed that it may have been out of sync when taking over as the new active server. The other replica nodes will sync up, but it is possible that a recent configuration change may have been partially or completely lost.), (Recommended Action: Check any recent commits to see if the configuration has been lost. Run 'clear configuration inconsistency' for the relevant plane.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_MPLS_EA-3-ERR_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in MPLS EA. Typically, this is an error where the software fails to initialize or programming of forwarding feature fails. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef mpls trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-4-AO_KEYCHAIN_GET_KEY_RETRY ### Response: (Severity: 4), (Category: IP), (Description: TCP AO tries to query keychain key detail and unable to get which is of type6. User needs to check the command to verify whether Masterkey key is being configured and enabled. If it has already been configured and enabled then this indicates an issue. TCP AO will continue to retry until it gets the key string details.), (Recommended Action: Please check in whether Masterkey has been configured and enabled. if this is not the case. please configure the masterkey immediately. user can configure the masterkey by this exec command - ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TIMER-3-TWOSERROR ### Response: (Severity: 3), (Category: OS), (Description: OS call failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-TMB_CLUSTER_PARITY ### Response: (Severity: 0), (Category: PLATFORM), (Description: A parity error interrupt), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDBUTILS-6-MUTEX_UNLOCK_FAIL ### Response: (Severity: 6), (Category: SYSDB), (Description: Unlock operation failed on SysDB log file.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-2-DELAYED_DELETE_RC ### Response: (Severity: 2), (Category: ROUTING), (Description: It is not expected to hit a failure during delayed delete.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_IM_INTERFACE_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: Error while creating an IM interface.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_TOPAZ-7-ERR_ASIC_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while initializing the CPU control ASIC to either receive packets from the fabricq ASIC or transmit packets from the ingressq ASIC. This is crucial for the process and is automatically restarted on this failure.), (Recommended Action: If problem either persists (following a process restart) then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_FT_OIR ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when any FT is OIR'ed from satellite.), (Recommended Action: Please reinsert the FT back in the satellite.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BAG_SCHEMA-4-ERR_LTRACE ### Response: (Severity: 4), (Category: INFRA), (Description: Bag Schema Server encountered an error using the Lightweight Tracing service. The error message describes what operation has failed and why it failed. This is a fatal error and the Bag Schema Server process cannot continue. It will abort and subsequently be restarted by SysMgr in an attempt to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-3-DAEMON_INIT_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The Ethernet Link OAM Daemon failed to initialize correctly, and will now exit. It should be restarted by SysMgr.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_IPV6_EA-5-DEBUG ### Response: (Severity: 5), (Category: PLATFORM), (Description: SSE IP-EA, Debug information), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_QFPCPUCTRL-1-BOARD_REV_PAR_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: CPU controller board revision parity error encountered on either mother board or daughter board), (Recommended Action: Upgrade the CPU controller FPGA image, and reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_LSD_CLIENT-4-ERR_CLIENT_API_CALL_NOTCONN ### Response: (Severity: 4), (Category: ROUTING), (Description: LSD client was not connected and an lsd client api was called.), (Recommended Action: Collect LSD traces) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-SWITCH_ACCESS_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process is no longer able to access the switch's internal registers, so is unable to manage the switch. In order to recover, ESD will reset the switch, then exit so that it will be restarted by the process manager.), (Recommended Action: If this problem does not recur, no intervention is required to recover. To determine why this problem occurred, or if the problem occurs multiple times, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet', and 'show controllers switch trace' commands. Also collect the OS kernel logs. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-2-MODULE_AND_PORT_SPEED_MISMATCH ### Response: (Severity: 2), (Category: L2), (Description: The speed on the module present in the port is different with the speed of the port configured via portmode), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM-3-ERROR_RUN_BMON ### Response: (Severity: 3), (Category: MEDIA), (Description: pthread_create() returns error), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-3-PULSE_ATTACH_ERR ### Response: (Severity: 3), (Category: OS), (Description: This is during the device Initialization. Unable to attach qnet input pulse to use the dispatch manager to call my local function when data becomes available %s- Error description), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-3-CLEANUP ### Response: (Severity: 3), (Category: IP), (Description: The XR socket library failed to clean up correctly and return to the original state after a socket operation failed. This may result in stale state and an inconsistent view of the socket between IOS-XR processes and standard Linux processes. This can prevent this socket being used for communication with local Linux processes. Further, it can cause traffic destined for Linux processes to get dropped.), (Recommended Action: Restarting the affected process is expected to resolve the inconsistency. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_TOPAZ-7-ERR_EVM_CREATE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while attempting to create an event manager. This failures affects the ability of the process to service various messages / pulses from other threads / processes. This facility is deemed crucial and the process automatically restarts on this failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-2-TRANSCEIVER_REMOVED ### Response: (Severity: 2), (Category: PLATFORM), (Description: The optic interface module was removed on the given interface which will result in a link down. The traffic may start getting dropped after this error message), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-DEST_CONNECTED ### Response: (Severity: 3), (Category: FORWARDING), (Description: It is invalid for a subnetted tunnel destination to resolve to a connected prefix. When this message is displayed, the user must change the tunnel destination or change the routing configuration. When this is corrected, the tunnel will re-evaluate its state and come UP if other criteria for tunnel to be up are satisfied.), (Recommended Action: Change the tunnel destination or change the route resolution.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSVP-5-BAD_RSVP_MSG_RCVD_AUTH_DIGEST ### Response: (Severity: 5), (Category: ROUTING), (Description: The router received an RSVP message with a bad integrity digest. RSVP discarded the message because the digest verification failed. The 'key-strings' used may not be configured the same on both sender/receiver.), (Recommended Action: Check the configuration on the router and sending system to make sure that the authentication configuration is compatible. Especially ensure that the key-strings for the specified key ID's match. Also ensure that the peer is using a supported HMAC cryptographic-algorithm.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ERRDIS-4-BLOCK_UNTIL_ACTIVE ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: This is a fatal error for the standby verification daemon process. Unless this is resolved, the standby process will not be informed when the node goes active following a failover event. The process will restart in an attempt to clear the error.), (Recommended Action: If the error message indicates a potential out of memory condition Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Otherwise, this indicates a problem with the sysmgr infra, Gather 'show tech-support sysmgr'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel mesh feature? ### Response: The MPLS TE auto-tunnel mesh feature enables the automatic creation of a full mesh of MPLS TE tunnels between a set of routers. It greatly simplifies the provisioning of TE tunnels in a full mesh topology. Auto-tunnels are created between each pair of routers in the specified mesh group. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FHRP_OUTPUT-3-ERR_NO_MEM ### Response: (Severity: 3), (Category: IP), (Description: The FHRP Output process was not able to allocate the memory that it needed to complete the operation. FHRP Output process client functionality on the affected node may be reduced until the problem is resolved.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-INITIAL_IMAGE_MINI_ISO_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: Mini iso found in the list of initial images. Invalid input.), (Recommended Action: Check if mini iso is provided in the list for initial image and if yes please exclude the same.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_SOCKET-3-SYSMGR ### Response: (Severity: 3), (Category: L2), (Description: fr_socket process was initialized successfully but was either unable to inform System Manager of the success or possibly System Manager itself was not able to collect the process status.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-bandwidth max and min feature? ### Response: The MPLS TE auto-bandwidth max and min feature specifies the maximum and minimum bandwidth values that auto-bandwidth can request for a tunnel. The max value limits how high auto-bandwidth can adjust the tunnel bandwidth, while the min value specifies the lowest bandwidth auto-bandwidth can request. These values constrain the auto-bandwidth adjustments. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-4-BD_MST_LOOP ### Response: (Severity: 4), (Category: L2), (Description: A potential mis-configuration with more than one sub-interfaces in this bridge domain from the same main port and having the same msti value.), (Recommended Action: To recover from this fault it is recommended to delete from the bridge domain the extra sub-interfaces belonging to the same main port and in the same msti.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VASI_EA-3-SSC_SEND_SRV ### Response: (Severity: 3), (Category: SERVICES), (Description: A problem was encountered while trying to send a single message to the Service Director. The Service Director may not be up to date with the state of this services on this node, so the associated VASI interfaces located on this node may fail to forward packets.), (Recommended Action: It may help to restart the VASI EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-5-CLOCK_INTERFACE_PORT_1_OUTPUT_SQUELCHED ### Response: (Severity: 5), (Category: PLATFORM), (Description: When no external clock source is available, this status propagates to BITS output ports in 2MHz and 6.312MHz modes. When an external source is qualified, this alarm will be cleared.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-6-DISABLED ### Response: (Severity: 6), (Category: LICENSE), (Description: Smart Agent has been disabled.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_SDFEC_OOM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-CLEAR_REDQ_ENTRY_FAIL ### Response: (Severity: 3), (Category: QOS), (Description: QMgr encountered an error while programming redq entry for an interface default queue in the associated PSE), (Recommended Action: REDQ drop threshold could not be reset to 0. Collect the syslog and debug info and) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRP_MAD-3-PARTICIPANT_NOT_FOUND ### Response: (Severity: 3), (Category: L2), (Description: An MRPDU was received on an interface where there is no participant. The specific MRPDU will be dropped and the protocol will continue to operate.), (Recommended Action: If the interface is configured to be running MRP this indicates a database inconsistency. Attempting to restart the process outputting this message may clear this inconsistency. If the interface is not configured to be running MRP, this indicates a problem in the packet path, a process restart may restore the correct paths. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPDRIVER-3-SERDES_IMEM_MULTIPLE_BIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that during initialization the SERDES SPICO for the indicated ring, NP and serdes instance had uncorrectable bit errors in instruction memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-3-CAN_CARD_INVALID ### Response: (Severity: 3), (Category: PLATFORM), (Description: The card type read from the CAN Bus is not recognized to be valid. The shelfmgr will not bootup this card. The 'show platform' CLI will not show a card for this slot.), (Recommended Action: Please take the following series of actions until the 'show platform' CLI shows the expected valid card type and this error message does not appear on the console. 1- Issue the following process restart commands in sequence and then see if the error message goes away and 'show platform' CLI indicates a valid card type:: process restart can-server location process restart shelfmgr location 2- If the issue is not yet resolved, please reseat the affected card carefully, making sure it is fully inserted into the backplane. Try different slots in the chassis if needed. See if the error goes away. 3- If the error persists, please contact your Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_MAP-4-OOR_THRESHOLD ### Response: (Severity: 4), (Category: ROUTING), (Description: This router has reached the threshold value for the number of Auto-RP mapping agent cache entries. This is a warning that the maximum value is being approached and steps should be immediately taken to reduce the number of cache entries or to configure a higher maximum value.), (Recommended Action: Consider reducing the number of group-to-RP mappings advertised from some set of the candidate-RPs or consider reducing the number of candidate-RPs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS traffic engineering forwarding adjacency feature? ### Response: The MPLS traffic engineering forwarding adjacency feature allows an MPLS TE tunnel <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-MANS_INIT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in MANS initialization. This means that MANS is currently in Factory mode and this will cause the Services PLIM driver initialization to get blocked.), (Recommended Action: Upgrade MANS with Field FPGA image If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZL30363-5-CLOCK_STATUS ### Response: (Severity: 5), (Category: PLATFORM), (Description: Clock loss/selection is detected with zarlink device zl30363 for PLL0.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the significance of Route Distinguisher (RD) in Cisco IOS XR MPLS VPNs? ### Response: The Route Distinguisher (RD) in Cisco IOS XR MPLS VPNs is used to distinguish between identical IP prefixes in different VPNs, allowing for overlapping address spaces while keeping the traffic segregated. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-FILELIMIT_TOO_SMALL ### Response: (Severity: 3), (Category: OS), (Description: A file's max limit is too small, or internal parameter might be corrupted. This might be because of a corrupted record or Upgrade of system.), (Recommended Action: The file should be saved to other place for later debugging, and then it should be removed to recover current situation. Please clear the OBFL files, as it might be because of corrupted records. CLI : admin clear logging onboard corrupted-files location If the issue is seen after clearing the files, please collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging 5. show tech-support sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_L2TP-6-LTRACE_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the ltrace module in the platform L2FIB L2TP component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-4-CHKPT_SAVE_FAILURE ### Response: (Severity: 4), (Category: SECURITY), (Description: Encountered a checkpoint save failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERDES-2-TX_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A transmit fault occurred at the physical layer on the port. It is an indication of fault in MAC/Serdes/Module. In most cases, the fault would bring the link down and cause complete traffic drop.), (Recommended Action: Please contact Cisco support and provide the output of following commands: 'show controllers tenGigE all'. 'show serdes trace configuration location <>' 'show serdes trace periodic location <>' 'show serdes trace interrupt location <>' 'show tech-support ethernet interface location ' 'show hw-module fpd location all' 'admin show inventory') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_LOCAL-6-CLEAR_COUNTERS ### Response: (Severity: 6), (Category: L2), (Description: Counters on a sonet controller has been cleared by the user. This message is for information only.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS VPN Inter-AS feature? ### Response: The MPLS VPN Inter-AS feature allows MPLS VPN services to span multiple autonomous systems. It enables VPN connectivity between sites attached to separate autonomous systems. There are different options for implementing Inter-AS MPLS VPN, with varying levels of scalability, isolation, and complexity. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: orrspf-4-INIT_ERROR ### Response: (Severity: 4), (Category: ROUTING), (Description: The ORRSPF process failed to initialize correctly.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDM_LIB-6-DEBUG_ERROR ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an info message in the RDM lib to indicate that it may have failed at some check or representing the code flow), (Recommended Action: If this message recurs, copy the system message exactly as it appears on the console or in the system log. Collect the following information and contact your Cisco technical support representative. Provide the representative with the gathered information. - show logging - show tech rdm - show tech npu) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp bestpath as-path ignore' command in IOS XR BGP configuration? ### Response: The 'bgp bestpath as-path ignore' command is used to ignore the AS path length when selecting the best path. By default, BGP prefers the path with the shortest AS path length. This command disables that behavior, allowing the selection of a path with a longer AS path if it is better in other attributes such as origin or MED. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-7-INIT_FAILED ### Response: (Severity: 7), (Category: IP), (Description: Initialization of the IPv4 MA process failed. This can happen when the process is (re)starting and any basic infrastructure service required by the process is not available. The process recovers by restarting itself. If the error message doesn't persist, it can be ignored. If the error message persists, some basic ipv4 functionality may not be available.), (Recommended Action: Collect the output of show tech-support, show processes, show ipv4 ma trace from the location the error message comes from.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STANDBY-3-ERR_EDM_NOTIFY ### Response: (Severity: 3), (Category: IP), (Description: HSRP has failed to notify the system that the specified event has occurred.), (Recommended Action: Restart the HSRP process. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-4-WARNING_X509 ### Response: (Severity: 4), (Category: SECURITY), (Description: ssh warning messages.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-4-ERR_LTRACE_INIT ### Response: (Severity: 4), (Category: ROUTING), (Description: Error ocured while enabling mcast), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-ASIC_INIT_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Crossbar fabric interface ASIC-0 failed during init.), (Recommended Action: Reboot the board. If the error persists, contact TAC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-INVALID_PLATFORM_TYPE ### Response: (Severity: 3), (Category: OS), (Description: The QSM process wasn't able to startup up due the indicated failure during initialization. A restart of the process will be attempted. If the process can not be sucessfully started after several attempts, the board will probably be unusable.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-3-CONFIG_INIT ### Response: (Severity: 3), (Category: IP), (Description: The IPV6 MA process failed to initialize its config handling mechanism and interaction with sysdb.), (Recommended Action: Restarting ipv6_ma and sysdb may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BANNER-3-EVENT_BLOCK_ERROR ### Response: (Severity: 3), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-EVM_NULL ### Response: (Severity: 3), (Category: OS), (Description: Evm null. Recovery occurs with automatic process restart.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-MEMORY ### Response: (Severity: 3), (Category: MGBL), (Description: The server has failed to acquire the required amount of memory), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does LPTS classify and police traffic flows to the router? ### Response: LPTS classifies traffic flows based on various packet header fields like source IP, destination IP, protocol, ports etc. It then assigns the flows to one of several pre-defined flow types. Each flow type has a configured rate limit. Packets exceeding the rate limit are dropped. This protects the router resources from being overwhelmed. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-IMG_DLOAD_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in downloading Linux/Application image. Cause of the error will be mentioned in the message displayed. This error prevents Services PLIM from coming up to its full functional Active state.), (Recommended Action: Do cold reboot of Services PLIM MSC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AIB-4-IDB_NOT_FOUND ### Response: (Severity: 4), (Category: ROUTING), (Description: AIB maintains a database for interfaces, but was unable to add an entry to it. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: Please review the output of the following commands: show adjacency trace all location | include show im database ifh detail location If the explanatory detail indicates memory exhaustion, Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-MANDATORY_REBOOT_ENABLE ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKWATCH-3-PTCL_DOUBLE_FREE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An attempt has been made to free a packet buffer that is already freed. This usually indicates the process using the particle has used it after it has been returned.), (Recommended Action: Please collect a core dump of the process from which the message is output, using the 'dumpcore running' command to catch the current packet memory state ('exception pakmem on' must also be configured). Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-6-HA_ROLE_CHANGED ### Response: (Severity: 6), (Category: LICENSE), (Description: Smart Agent role on HA RP has been changed to either active or standby.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-CHKPT_RESTORE_DEBUG_SUCCESS ### Response: (Severity: 3), (Category: OS), (Description: chkpt_iterate_* failed while iterating through the chkpt list.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-3-FAIL_TO_GET_BP_MAP_FROM_PLIM_AISC ### Response: (Severity: 3), (Category: L2), (Description: Sharq driver invoke Plim ASIC dll to retrieve the per port backpressure map but failed.), (Recommended Action: Please check Plim ASIC and related driver process status, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET-4-EDM_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the Ethernet stats controller EDM process. Under normal circumstances the process restarts with no impact to functionality. If this error message is seen repeatedly then 'show controller ... stats' commands (and their equivalents - e.g. via XML) will be unavailable.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-4-CBC_UART_RX_DROP_STATS ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is an informational message indicating that the cbc uart RX buffer overflow counters), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-GET_PROC_CISCO ### Response: (Severity: 6), (Category: OS), (Description: Dumper collects all the process related data by using system call devctl. If a devctl fails, then the core file will be incomplete. This will not impact the system.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAN_EA-6-UDF_ERROR ### Response: (Severity: 6), (Category: PLATFORM), (Description: The number of UDFs configured in the system are exceeding the MAX number supported by the Platform. Only the supported number of UDFs would be programmed/processed in the LC. All the excess ones would be considered a NO OP.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-TSPI_ASYNC_FIFO_OVFL ### Response: (Severity: 0), (Category: PLATFORM), (Description: TxSPI async FIFO overflow.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-MANS_OCTEON_MEM_RW_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in read/write from/to octeon memory of a mans fpga device register. This error could result in communication loss between MSC and Services PLIM.), (Recommended Action: Do warm reload of the Services PLIM MSC. If the issue persists do a cold reboot of the same. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_TCAM_ODS_DELETE ### Response: (Severity: 3), (Category: OS), (Description: TCAM ods delete error.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-2-RESET_RECOVERY_NOT_SUPPORTED ### Response: (Severity: 2), (Category: INFRA), (Description: When the Ethernet Switch Driver (ESD) process encounters certain switch errors, it initiates a switch reset recovery operation. This involves resetting the switch and then exiting the ESD process so that it is restarted by the process manager. When ESD determines that the switch does not support the reset recovery operation, ESD will escalate a fault to the shelf manager to reload the card in order to recover from the originally reported switch error.), (Recommended Action: No action further action is needed. However, the recommended action for the originally reported switch error should be followed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NFEA_HW_PROG-6-INFO_MSG ### Response: (Severity: 6), (Category: PLATFORM), (Description: Netflow punt rate is more than policer rate, it informs the user when such an event occurs), (Recommended Action: Reduce netflow sampling rate. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-2-ACCESS_FAILURE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Crossbar driver detected an issue with ASIC access.), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an L2VPN EVPN instance? ### Response: To configure an L2VPN EVPN instance, use the 'l2vpn evpn' command in global configuration mode. l2vpn evpn vpn-id 100 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-3-SHARED_MEM_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occured while opening shared memory), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC_CMN-5-rest_session_queue_limit ### Response: (Severity: 5), (Category: OS), (Description: Size of send queue exceeded limit. REST API is generating events faster, than REST client can consume. Higher number of notifications can be generated in case of problems in the network causing too many updates from IGP.), (Recommended Action: Check subscription and state of REST client. If client is already disconnected, but connection was not closed gracefully, then clear tcp pcb can be used to close that connection on the router. Decrease number of generated notifications by decreasing number of elements related to subscribed notifications (number of nodes, links or prefixes in topology if client is subscribed for topology notifications or number of LSPs if clients is subscribed for LSP notifications) or solve network issue causing increased number of events.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-0-SOFT_ERROR_RELOAD_RECOVERY_2 ### Response: (Severity: 0), (Category: PLATFORM), (Description: Soft error detected on Bridge FGPA instance 2. Card will be reloaded to cover from this error.), (Recommended Action: Soft error are very rare due to Cosmic and other environmental factors. The probability of soft error on same device again is extremely low. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_REDDRV-3-ERR_DCMD_PSARB_BLOCK_UNTIL_DELTA ### Response: (Severity: 3), (Category: PLATFORM), (Description: Software will automatically do recovery by restarting the reddrv process.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR support multicast routing? ### Response: Cisco IOS XR supports multicast routing through protocols like Protocol Independent Multicast (PIM) and Multicast Source Discovery Protocol (MSDP), facilitating efficient distribution of multicast traffic across a network. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE_UIDB-7-ERR_INIT ### Response: (Severity: 7), (Category: L2), (Description: Initialization of uidb_svr process has failed due to one of the following reasons: 1) Failed to create server context. 2) Failed to get schedular parameters. 3) Failed to initialize event manager. This would prevent process from receiving events. 4) Failed to register with debug. This would prevent process from logging debug messages. 5) Failed to bind UIDB server with MIPC server. This is needed to program features in hardware. 6) Failed to connect to PLIM asic processes. This is needed to program features in hardware. 7) Failed to initialize checkpoint. This is needed to checkpoint UIDB data to restore on process restart. 8) Failed to allocate, initialize and checkpoint shadow memory. This is needed to store and restore UIDB internal data. 9) Failed to get metro asic version. 10) Failed to attach event handlers needed to handle LWM messages. This is needed to enable/disable various features in hardware. 11) Various Sysdb or EDM failures 12) event_block failed. This indicates process has encountered unexpected error while waiting for events.), (Recommended Action: No action is required. Process will be restarted. If not recovered, it's a fatal condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-CHKPT_RESTORE_ATTR ### Response: (Severity: 3), (Category: OS), (Description: nrs_chm_chkpt_create_attr failed while restoring the set attributes from chkpt shared memory after nrs server process restarts.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET_LOOPBACK-3-PRM_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to initialize PRM connection in the platform Ethernet loopback component), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-3-ERR_ASIC_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabricq Asic driver encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_MCAST-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM MCAST, error), (Recommended Action: Please collect the console log, multicast traces (show mfib trace loc <>, show mfib hardware ltrace location <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_LTRACE-7-ERR_INFO_VERBOSE ### Response: (Severity: 7), (Category: PLATFORM), (Description: PLATFORM L2FIB, error information), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to activate a software package in Cisco IOS XR? ### Response: To activate a software package, making it the active version on the router, use the 'install activate' command. RP/0/RSP0/CPU0:router#install activate package-name <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-3-MSG_CERR_REGISTER_DLL ### Response: (Severity: 3), (Category: HA), (Description: The call register the dll using cerr_register_dll failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_DLIST_SET_MORE_FLAG ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The attempt to set the 'more data' flag to an external data manager datalist has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR handle software package dependencies during installation? ### Response: Cisco IOS XR automatically resolves software package dependencies during the installation process to ensure that all necessary components are installed for the proper functioning of the added packages. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIAAPI-4-INVALID_PARM_DEVICE_REMOVAL ### Response: (Severity: 4), (Category: MEDIA), (Description: An invalid parameter value was passed to the media driver when the media is removed.), (Recommended Action: Report this message to TAC. Capture console log, 'show media' and 'show media trace' output.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB_API-3-CORRPT ### Response: (Severity: 3), (Category: ROUTING), (Description: 'A corrupted update was received from the MRIB by the MRIB API'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBINST_DEBUG-4-INIT ### Response: (Severity: 4), (Category: INSTALL), (Description: There is a problem with the system infrastructure - perhaps the communication infrastructure has not yet stabilised. The process which encountered this problem will automatically restart. If other processes exhibiting similar behaviour, this is a system-wide issue.), (Recommended Action: The communication infrastructure may not be up yet. This error will be recovered automatically. No user action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How do you initiate a configuration rollback in IOS XR? ### Response: To initiate a configuration rollback in IOS XR, you can use the 'rollback configuration' command followed by the rollback point ID. The rollback point ID can be obtained using the 'show configuration rollback list' command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-SCRIPT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A problem was encountered while executing the indicated script.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDLD-4-DISABLE_PORT ### Response: (Severity: 4), (Category: PLATFORM), (Description: UDLD protocol detects if a link is uni-directional and disables the port. Uni-directional links can cause problems in ethernet networks and should be fixed.), (Recommended Action: Check the link on which the error happenned. Try replacing/reconnecting the GBIC/SFP/cable at either end of the link. Re-enable the port on the RP and see if the port comes up. If the problem still exists the port will be disabled again with this message. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_MFWD_FRETTA-3-ERR_GEN ### Response: (Severity: 3), (Category: ROUTING), (Description: MFWD-FRETTA library encountered error during setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POS-4-ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred during the initialization of the process. This resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XBAR-3-ERR_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Crossbar driver encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-RSPI_OUTOF_FRAME ### Response: (Severity: 1), (Category: PLATFORM), (Description: RxSPI out of frame.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can BGP prefixes be originated through redistribution? ### Response: Routes from an IGP or static routes can be redistributed into BGP using the redistribute command under the BGP process. By default, they are assigned an origin of incomplete (?). <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-BAD_CERT_USE ### Response: (Severity: 3), (Category: SECURITY), (Description: IKE found bad certificate was used), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-ING_FBU_POOL_EMPTY ### Response: (Severity: 3), (Category: PLATFORM), (Description: NP detects ING_FBU_POOL_EMPTY and reported through interrupts), (Recommended Action: No specific actions needed. The software should be able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cds_proxy-3-PROC_READY ### Response: (Severity: 3), (Category: OS), (Description: System manager process in not ready.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-ERR_ETIMEOUT ### Response: (Severity: 3), (Category: MGBL), (Description: 'Error while reading the file, Aborting the connection.'), (Recommended Action: Please consider increasing the tftp timeout value using, config CLI tftp client timeout.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-3-MUTEX_OP_FAILED ### Response: (Severity: 3), (Category: OS), (Description: 'Current operation on the mutex has failed.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-7-BOARD_POWERUP ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOMAIN_SERVICES-3-SYSMGR_PROC_READY ### Response: (Severity: 3), (Category: IP), (Description: domain services failed to notify the completion of initialization), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPM-3-ERROR_REGISTER_MESSAGE ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal error occured in Software Policy Manager (SPM) server.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-6-FAILED_BOOT_DURING_INSTALL_PAUSE ### Response: (Severity: 6), (Category: INSTALL), (Description: On bootup the node attempted to contact the Install Director on the dSC. The Install Director was contacted and informed the node that it could not boot because an installation was in progress. The Install Director then became unavailable. Therefore, to ensure that this node boots from an up to date Install Director it will reboot itself after a sufficient pause to ensure that the node the previous Install Director was on has had time to reboot. This message will only be seen on an RP.), (Recommended Action: The node will pause and then reboot to obtain the correct software. If the node ends in ROMMON (as the config-register was not set to auto-boot) then it is recommended to simply set the config-register to autoboot and reset to boot the correct software. unset BOOT sync confreg 0x2 reset) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_4_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SGT2_FIFO_OFLOW_0_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress sgt2 fifo overflow on xaui-0 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT-6-TEST_COMPLETED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-3-REQUEST_NETMGR_MOUNTPOINT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to request netmgr mountpoint.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'vrf' command in IOS XR? ### Response: The 'vrf' command is used to configure a Virtual Routing and Forwarding (VRF) instance. VRFs are used in MPLS L3VPNs to maintain separate routing and forwarding tables for each customer. Each VRF has its own set of interfaces, routing protocols, and forwarding policies. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-FAILED_ENS_REQUEST ### Response: (Severity: 4), (Category: INSTALL), (Description: The install director was not able to send an event notification. This will cause the system's install to fail in some way.), (Recommended Action: The Install director will automatically re-attempt to send the notification. No user action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-6-CERR_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the cerrno module in the platform L2FIB component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBC_RSRCMON-4-WARNING ### Response: (Severity: 4), (Category: SERVICES), (Description: The system is not able to carry on congestion handling.), (Recommended Action: Restart the sbc proces) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message in the DNX FIB to indicate that an error was seen during init operation. A return code is returned to PI which can do a retry or exit based on if error persists.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to display active software packages in Cisco IOS XR? ### Response: To display a list of active software packages on the router, use the 'show install active' command. RP/0/RSP0/CPU0:router#show install active <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAW_LIB-3-WRITE_FAILED ### Response: (Severity: 3), (Category: MEDIA), (Description: Reboot history index got corrupted. When recovering the reboot history index, file write operation failed. Please verify the reason why it is failed.), (Recommended Action: Erase the entire reboot history information is only option. Please execute 'erase nvram-raw: loc ' command to erase the reboot info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_PROXY-3-EXIT_PROCESS ### Response: (Severity: 3), (Category: FABRIC), (Description: The fabric proxy failed to create an event manager during the initialization. The driver will be non-operational due to this error.), (Recommended Action: The Proxy will recover by restarting. Verify that the fabric proxy process will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-3-DEBUG_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The length of the received message exceed the buffer size.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-PACKET_DECODE_FAILED ### Response: (Severity: 4), (Category: L2), (Description: An error occurred while attempting to decode a batch of ethernet frames which had been received. The source of the error is the Ethernet Packet Infrastructure. The received packets will be dropped as a result of this error. This could cause peer MEPs to time out, or ping/traceroute operations to fail.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-6-INFO_INTERNAL_TABLE ### Response: (Severity: 6), (Category: OS), (Description: During processing of a show command, the internal LPTS data structures changed in such a way as to make completion of the show command impossible.), (Recommended Action: Try restarting netio process and then, retry the command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFMMIB-4-LOCK_ERROR ### Response: (Severity: 4), (Category: L2), (Description: The DOT1AG/MEF SOAM PM MIB DLL encountered an error while trying to perform an operation on a lock. The thread will continue without retrying the operation. In most cases, no further adverse behaviour should be observed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-MAX_REDIST_PREFIXES ### Response: (Severity: 4), (Category: ROUTING), (Description: This configuration is redistibuting more than the allowable number of prefixes into an IS-IS topology. IS-IS will not advertise some of these routes. This is to prevent inadvertant redistribution of the Internet via IS-IS.), (Recommended Action: Consider reconfiguring route redistribution into the IS-IS process. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_VPLS-7-NHOP_TXLIST_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: PWHE txlist and ifh size exceeded.), (Recommended Action: *NONE* Platform software will correct itself if this happens) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-CSFI_TIMER ### Response: (Severity: 3), (Category: L2), (Description: An error occurred while starting or restarting the CSF generation timer. No further CSF messages will be sent for MEPs in this domain/service.), (Recommended Action: Unconfigure CSF generation for this service, commit the configuration, then reconfigure it. If the problem persists, it may be possible to recover by restarting the 'cfmd' process on the node where the problem occurs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-SLOTID_PARITY_ERROR ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC has detected that the slotid of the card doesn't have correct parity, this can becaused by backplane connectors that has been damaged due to bent pins.), (Recommended Action: Please inspect the backplane and card connectors for physical damages.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-IGNORE_REMOTE_RESET_EVENT ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates that the REMOTE_RESET event is received when the node is in isolated state. No action is taken as sysmgr will not allow the node to reboot.), (Recommended Action: *none*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_HEAP-7-BAD_HEAPPTR ### Response: (Severity: 7), (Category: HA), (Description: Internally heap pointers are kept as offset indices. A given heap pointer was found to be outside the heap.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-3-PROT_BFD_SESSION_DOWN_MESSAGE_LOST ### Response: (Severity: 3), (Category: L2), (Description: One or more PROT_BFD_SESSION_DOWN PFI fast protect event has been lost. If a link which BFD session failed happened to be fast-reroute protected, fast-reroute may not have been triggered.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-MISS_EOP_1_XAUI_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Missing EOP-1 from XAUI on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-3-INIT ### Response: (Severity: 3), (Category: OS), (Description: The chunk's mutex could not be initialized.), (Recommended Action: Copy the message exactly as it appears, and report it your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTR8 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-PORT_FWD_ERR_ERRNO ### Response: (Severity: 3), (Category: SECURITY), (Description: SSH port forwarding encounterd some error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_35 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-ISSU_RELOAD_NODE ### Response: (Severity: 3), (Category: INSTALL), (Description: As part of ISSU operation, the specified node that was warm reloaded (iMDRed) has encountered the specified failure and thus is being reloaded by the install ISSU infrastructure.), (Recommended Action: No action is required. If the node remains in failed state afer reload, please contact support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_PAK_AUTH ### Response: (Severity: 3), (Category: ROUTING), (Description: Authentication failure during RIP send/receive packets.), (Recommended Action: Please check to make sure RIP interface authentication configuration is correct. If key chains are used, please make sure atleast one active key is available for send operation. Please make sure both send and receive interfaces are configured with the same authentication mode. For text authentication mode, please make sure the active password used on the send interface key chain is also active on the receive interface key chain. For MD5 authentication mode, please make sure the active key ID and password used on the send interface key chain is also active on the receive interface key chain.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-3-DB_DISK ### Response: (Severity: 3), (Category: MGBL), (Description: The specified storage device is full or some files can not be deleted.), (Recommended Action: Use the 'delete' command to free up some space on the storage device.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFSTATS-4-COLLECTOR_TIMEOUT ### Response: (Severity: 4), (Category: MGBL), (Description: The stats collector process that is described by the Node and PID in this message has timed out during a stats request. This may result in some stats being out of date.), (Recommended Action: If this continues to be seen then investigate the process that is causing this message. If the Node and PID are 'UNKNOWN' then 'show proc blocked' should be used to find the unresponsive collector.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-I2C_FAILURE_ZONE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This I2C failure indicates that a fault occurred when checking the circuit breaker status on the shelf.), (Recommended Action: Try doing restarts of below process admin process restart envmon loc <>. admin process restart i2c_server loc <>. Location is from the node on which this ios_msg is seen. If the issue still persists collect required_info) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-ESI_FWD_PBB_EVPN_INCOMPATIBLE ### Response: (Severity: 3), (Category: L2), (Description: A forwarder of incompatible EVPN type is being added to an Ethernet-segment. PBB-EVPN technology is not supported alongside other EVPN technologies on a single ethernet segment. This can be the result of a misconfiguration.), (Recommended Action: Review EVPN and L2VPN configuration to determine where interfaces or bridge ports (subinterfaces) have been configured, which will fall under the same Ethernet Segment and remove them.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RUNTIME-6-EXIT_CODE ### Response: (Severity: 6), (Category: OS), (Description: Exit code of the process is displayed), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REPLICATOR-7-INTERNAL ### Response: (Severity: 7), (Category: LIBRARY), (Description: The replicator library has either failed a function that expected to succeed, or has got into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-BF_MBE_ERR_FIA01 ### Response: (Severity: 3), (Category: PLATFORM), (Description: FIA01 burst FIFO multi-bit error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SEG_HDR_EXT_FIFO_OFLOW_0_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress seg hdr ext fifo overflow on xaui-0 bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-7-VERBOSE_INT_HEX ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_SSL-3-CERT_VERIFY_ERR_2_PARAM ### Response: (Severity: 3), (Category: SECURITY), (Description: SSL certficate verify error message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_SOCKET-3-CONN ### Response: (Severity: 3), (Category: L2), (Description: The fr_socket process failed to connect to the event manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the two main features used to secure the forwarding plane in Cisco IOS XR? ### Response: The two main features used to secure the forwarding plane are: 1) Access Control Lists (ACLs) which filter traffic based on configured rules. 2) Unicast Reverse Path Forwarding (uRPF) which helps prevent IP spoofing by verifying that packets are received on the interface that the router would use to forward back to the source. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_SOCKET-3-RESMGR_ATTACH ### Response: (Severity: 3), (Category: L2), (Description: The fr_socket process failed to advertise itself to the system as a resource manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-3-PTHREAD_MUTEX_LOCK_FAILED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFD_HELPER-3-ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: An error was encountered. The failure of this is not critical to confd helper but may have significant impact to general system operation.), (Recommended Action: If the error persists, copy the error message and trace exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_MPLS_EA-3-ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in MPLS EA. Typically, this is an error where the software fails to initialize or programming of forwarding feature fails. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef trace location <> show cef platform trace common all location <> show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_MAP-3-INIT_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: The autorp mapping agent failed to initialize successfully.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show processes autorp_map_agent detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes autorp_map_agent detail output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp mapping-agent trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp mapping-agent trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging process autorp_map_agent error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging process autorp_map_agent error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSUDIR-1-OPERATION_ABORT_PREV ### Response: (Severity: 1), (Category: INSTALL), (Description: ISSU operation aborted because an error was encountered in the previous operation.), (Recommended Action: The reason for this issu operation failure has to be analyzed. Check the issu operation log by 'show tech-support issu' to understand the reason for the operation abort. Collect the show tech logs by running 'show tech-support issu' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_CLI-7-FILE_GARBAGE ### Response: (Severity: 7), (Category: OS), (Description: File has garbage bytes at the end.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_8_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-DEPRECATED_RTRID ### Response: (Severity: 4), (Category: ROUTING), (Description: OSPF router-id has been deprecated.), (Recommended Action: Use router-id .) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9k_IFLX-5-FRONT_PORT_SHARING_WARNING ### Response: (Severity: 5), (Category: PLATFORM), (Description: Only 10/100M IFLX front port sharing mode is supported. No explicit blocking), (Recommended Action: Do not config unsupported IFLX front port sharing mode) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR-3-MA_INIT ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates that an error has occurred during the 'pbr_ma' process initialization and it may prevent PBR from functioning. Particular reason is included in the message), (Recommended Action: Allow the 'pbr_ma' process to restart with the command process restart pbr_ma location . If the problem persists, contact Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: L2), (Description: System failed to allocate memory. It's likely that the system is running low on memory. Following are some reasons: 1) Failed to allocate memory for Egressq client add. 2) Failed to allocate memory for Egressq mapping table. 3) Failed to allocate memory for Queue leaky bucket limit table Memory. 4) Failed to allocate memory for Queue leaky bucket limit table memory. 5) Failed to allocate memory for Group leaky bucket limit table memory. 6) Failed to allocate memory for Group leaky bucket limit table memory. 7) Failed to allocate memory for Port leaky bucket limit table memory. 8) Failed to allocate memory for PLIM Asic back pressure table memory.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-MAC_1_RX_FRAME_ERR_2 ### Response: (Severity: 2), (Category: PLATFORM), (Description: MAC on NPU-1 received an errored frame interface on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-6-IP_ARM ### Response: (Severity: 6), (Category: IP), (Description: 'The call to ip_addr_c_init() failed'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-4-SHM_DIR_ERR ### Response: (Severity: 4), (Category: OS), (Description: Shmwin server failed to retrieve shmwin window list information.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture - show shmwin trace server location 0/x/CPUx) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_COM_IFIB-3-CONFIG_UNKNOWN_PARAMETER ### Response: (Severity: 3), (Category: OS), (Description: Syntax error in IFIB flow handling configuration. The named flow type may have default characteristics applied.), (Recommended Action: Provide the following log: Collect Console logs and following Information -From the Shell promt of LC and RP, fetch the file /pkg/etc/inflow.conf) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different MPLS TE FRR protection modes? ### Response: The different MPLS TE FRR protection modes are\n- Link protection: Protects against link failure. Backup tunnel is routed around the protected link.\n- Node protection: Protects against node failure. Backup tunnel avoids the protected node.\n- Best-effort protection: Tries to protect against both link and node failure, but does not guarantee it.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure RSVP authentication? ### Response: To configure RSVP authentication, use the 'rsvp authentication' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#rsvp authentication key-chain myKeyChain <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-4-RSRC_LOW ### Response: (Severity: 4), (Category: ROUTING), (Description: The FIB process has detected that average utilization for specified resource has risen above a predefined high watermark value, and has enterred resource contrained forwarding mode. In this mode, the cef will only handle route deletes which may potentially freeup some memory. Due to this operational mode, RIB and FIB will be out of sync. Once routes are deleted and resource utilization level drops to acceptable levels again, cef will come out of this operational mode and resume normal operation.), (Recommended Action: Run the following command and check which resource(s) are running low on memory: show cef resource location Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Any action that reduces number of routes for this protocol (results in route delete events to free up resources below predefined level) will eventually result in the FIB returning to normal operation after few seconds.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-3-ALARM_CLEARED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Alarm cleared received from CBC, condition has alleviated.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LICENSE-6-ENFORCE_INC ### Response: (Severity: 6), (Category: LICENSE), (Description: The licensed feature is enabled with appropriate licenses.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-4-TLVLIB_INIT ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when trying to initialize with tlvlib.), (Recommended Action: Restarting pifibm_server_lc and pifibm_server_rp may fix the issue. If the issue is still seen please collect the output of the following commands: - show tech-support lpts - show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKWATCH-3-PAK_DOUBLE_FREE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An attempt has been made to free a packet buffer that is already freed or that a buffer that is not owned by the calling process. This usually indicates the process using the packet has used it after it has been returned or after it has been sent to another process.), (Recommended Action: Please collect a core dump of the process from which the message is output, using the 'dumpcore running' command to catch the current packet memory state ('exception pakmem on' must also be configured), the full console logs and 'show proc pidin loc ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-ACL_COMPRESSION_NO_SUPPORT_LC ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: ACL with compression requires a TCAM card and sometimes, depending on card type, also requires allocation of TCAM space to ACL.), (Recommended Action: Re-attach the ACL in uncompressed mode (compression level 0), use a card with external TCAM, or allocate space to ACL via the hw-module command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-6-LEN_TOO_LONG ### Response: (Severity: 6), (Category: SECURITY), (Description: An internal software error has occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MMAP_PEER-6-SEND ### Response: (Severity: 6), (Category: OS), (Description: Failed send() for a domain socket.), (Recommended Action: This message is informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB_QUERY_ORA-3-RUN ### Response: (Severity: 3), (Category: ROUTING), (Description: There was an internal software error in the routing policy library and as a result routing policy may not be applied correctly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-6-BUS_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: A PCIe bus error has occurred. The message has the device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSLA-5-INTERNAL ### Response: (Severity: 5), (Category: MGBL), (Description: IPSLA module incurred an internal error. This could happen in various situations. Such as system low on memory or communication failures with other processes.), (Recommended Action: Try restarting the IPSLA process showing this error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_VCM-3-NOMEM ### Response: (Severity: 3), (Category: L2), (Description: The system might be running low on memory and adequate amount of memory was not available to complete the request), (Recommended Action: Check the box for processes with excessive memory If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_AGORA_ALM_TYPE_ONE ### Response: (Severity: 2), (Category: PLATFORM), (Description: AGORA type one alarm.), (Recommended Action: If the problem persists, call your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-2-PLAT_ENCAP_RSRC_LIMIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: DPA failed to create a MPLS Encap due to resource limit.), (Recommended Action: Please collect the console log, DPA traces (show dpa trace loc <>), NPU Resources (show controllers npu resources encap loc <>) show controllers fia diagshell 0 'diag alloc eedb' loc <> The failure could be because we ran out of available encap resource. Report to your technical support representative for further details.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTSDRVR-3-OTS_OTDR_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates an OTDR failure), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UPGRADE_FPD-6-STATUS_LOC ### Response: (Severity: 6), (Category: PLATFORM), (Description: It indicates the status of FPD upgrade on a particular location.), (Recommended Action: This is information only to notify the user that upgrade is going for perticular LC and no action is needed from user perspective. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_GIFT-3-INTF_RETRY_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The hardware configuration for the Interface has reached the maximum number of retries. Hitting this error typically indicates that the interface has either hit physical interface creation failures, or has not been cleaned up properly.), (Recommended Action: Reload the relevant LC(s) to recover.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OT-4-UNKNOWN_BFD_EVENT ### Response: (Severity: 4), (Category: SERVICES), (Description: BFD has sent an unknown event while creating the BFD session.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-5-CLOCK_INTERFACE_PORT_3_OUTPUT_SQUELCHED ### Response: (Severity: 5), (Category: PLATFORM), (Description: When no external clock source is available, this status propagates to BITS output ports in 2MHz, 6MHz and 64KHz modes. When an external source is qualified, this alarm will be cleared.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-BFD_SEND_FAILED ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to send a msg to BFD server.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSS-3-ERR_BAG_REG ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric statistics server process encountered an error to register the bag to bag infrastructure that is useful for packaging up complex data into single SysDB items. This software error will cause process termination for recovery The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-INRESET_INV_CARD_TYPE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the board type cannot be recognized, therefore, the node will not be able to boot up. This usually caused by an invalid eeprom content.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKEv2-6-NO_PROPOSAL_CHOSEN ### Response: (Severity: 6), (Category: SECURITY), (Description: Negotiation failed with peer, No Proposal with same capability found.), (Recommended Action: Contact the remote peer's administrator, choose proposal with similar capabilities on both ends.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-SUSPENSION_START_REQUEST_RECEIVED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL-3-API_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The specified API returned the specified error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_TX_FIFO_OFLOW_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI interface to NPU-0 reported tx fifo overflow on bridge instance - 2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_LOS_PORTP ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSDIR-4-QS_MANAGER_START_FAIL ### Response: (Severity: 4), (Category: INSTALL), (Description: Process Manager has returned an error indicating that it could not start Quickstart Manager on a particular node in response to Quickstart Director requesting it to do so. The Quickstart operation has been aborted as a direct consequence of this.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_SCP_ERRNO ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_1_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INIT-7-MBI_STARTED ### Response: (Severity: 7), (Category: OS), (Description: The MBI processes have all been started. This is not an error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-NO_SP_INFO ### Response: (Severity: 6), (Category: OS), (Description: No sub processor information found on this card. Display the local node information instead.), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-6-NEWLIMIT ### Response: (Severity: 6), (Category: ROUTING), (Description: User has changed the configuable resource limit.), (Recommended Action: No action required. This is an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SP_NOT_ZERO_0_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Non-zero seg profile detected on xaui-0 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_TF_INTR_FIFO_0LO_OVFL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_TF_INTR_FIFO_0LO_OVFL interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_PIDB-2-OPEN ### Response: (Severity: 2), (Category: PLATFORM), (Description: A run time error occurred while initializing the pidb on the linecard. The reason for the error is dispalyed. Please call Cisco Support with the error information), (Recommended Action: Please collect output of the following commands: show log show pidb trace show pidb error show pidb debug) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-3-APIV_MSG_SEND_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: API Version message send to the indicated target failed.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSE-3-ERR_EXIT ### Response: (Severity: 3), (Category: L2), (Description: An error occurred in PSE Driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message and gather the required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICCP-5-ISOLATION_CLR ### Response: (Severity: 5), (Category: INFRA), (Description: At least one configured backbone interface for the ICCP group is up.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SAT_PEM_NO_INPUT ### Response: (Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when one of the power cable to power module is unplugged on satellite.), (Recommended Action: Please check Power input connections to the satellite.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-NOTNBRTYPE ### Response: (Severity: 3), (Category: ROUTING), (Description: Neighbor address cannot be configured on the interface if it is not type NBMA or point to multipoint.), (Recommended Action: Correct the configuration of the network type on the interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR-7-ERR_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered the specified error during the initialization sequence. This facility is deemed crucial and hence the process is automatically restarted on this failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_COPY ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. This could be because the item to copy does not exist. The details are in the error string.), (Recommended Action: Check that the item to copy exists. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-RSI_TBL_ID ### Response: (Severity: 3), (Category: OS), (Description: The RSI failed to translate a vrf name into a tbl id.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MULTIVER-4-DLL_SIGNATURE_MISMATCH ### Response: (Severity: 4), (Category: ROUTING), (Description: There was a problem locating the DLL with matching signature - the problem is resolved by using existing dll installed on this node.), (Recommended Action: Check to make sure that there is no disparity in software installation across multiple nodes. Copy the output of 'show dll pid ' where PID is the process id of policy_repository process. Check all the install operations whether they are completed successfully Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDLD-5-NEIGHBOR_TIMEOUT ### Response: (Severity: 5), (Category: L2), (Description: All UDLD neighbors have been aged out. This could indicate traffic loss on the link. If UDLD is operating in aggressive mode on the port, the link will be disabled.), (Recommended Action: Correct the link fault, then re-enable UDLD using the following command: - ethernet udld reset interface ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_LOL_MAPPERB ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_7_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_ENA-3-BACKEND_SCAN ### Response: (Severity: 3), (Category: MGBL), (Description: The HTTP Server was unable to retrieve the specified item(s) from the SysDB component.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_DYNREG-4-AP_DATA_CONFLICT ### Response: (Severity: 4), (Category: ROUTING), (Description: An error was encountered as the node location was being added to the attach point item. This will prevent the successful registration for this attach point and will leave this configuration space unverified with respect to policy configuration.), (Recommended Action: Restart the policy_repository process and check for re-occurence of issue If problem persists, the please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-4-FSM_NVPAIR_ATTR ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: VPDN MGR failed process internal messages. This may be due to low memory conditions.), (Recommended Action: Allow the subscriber to reconnect. If the problem persists, contact Cisco support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBCORE-3-SYSDB_ACCESS ### Response: (Severity: 3), (Category: SNMP), (Description: SonetMIB API had trouble while binding/unbinding with SysDB. %s will indicate reason of failure), (Recommended Action: Sonet MIB is not able to bind with sysdb hence not able to fetch or copy some data into sysdb. Please collect below mentioned logs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-6-PSOC_UPGRADE_COMPLETED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message indicating that PSOC firmware upgrade is completed on the specified location.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-MALLOC_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Unable to malloc. Recovery occurs with automatic process restart.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show memory heap summary all location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show memory heap summary all location output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EM-7-FMS_LWM_SEND_ASYNC ### Response: (Severity: 7), (Category: HA), (Description: An internal error was detected when trying to send a pulse to a connection.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-BA_RESOURCE_FAIL_1 ### Response: (Severity: 3), (Category: IP), (Description: Unable to initialize internal data structure due to the process running low on resources.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the issue still persists then do the following. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-5-SATELLITE_REGISTRATION_FAILED ### Response: (Severity: 5), (Category: L2), (Description: CFM was unable to register to receive messages on Satellite access ports after multiple retries. CFM will continue to attempt to register, but may fail to function correctly on the Satellites affected.), (Recommended Action: The problem may resolve itself given sufficient time. If this error continues to appear, collect the required information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-3-ERROR_REGISTER_MSGNO ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel backup affinity feature? ### Response: The MPLS TE auto-tunnel backup affinity feature allows auto-tunnel backup tunnels to select or avoid links for the backup path based on configured affinity attributes. This provides more control over the backup path selection compared to the default behavior of using the IGP shortest path. Affinities allow backup paths to be optimized for specific requirements. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_6_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power greater than or equal to the high Tx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-6-GRP2_PLANE_CONNECTIVITY ### Response: (Severity: 6), (Category: FABRIC), (Description: 15th slot 400G MSC on chassis with PID: CRS-16-LCC-B needs either of plane 3 or 4. Without these planes, 400G MSC in 15th slot will be kept in IN-RESET state.), (Recommended Action: Check if atleast one of planes 3 or 4 are available in the system. Bring up any of these planes and then manually unpower 400G 15th slot MSC-X applying the below config. 'admin-config#hw-module power disable loc <>' and 'admin-config#no hw-module power disable loc <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSMGR-6-SCRIPT_TIMEOUT ### Response: (Severity: 6), (Category: OS), (Description: Script exceeded allotted time.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_GTRIE-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: PLATFORM FIB, Information), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-2-BOARD_REV_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: RSP CPU controller driver version is not compatible with the current Board.), (Recommended Action: Reset the board. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-COULD_NOT_AUTHENTICATE_HW ### Response: (Severity: 3), (Category: DRIVER), (Description: Card manager has failed to authenticate for Cisco HW genuine check This could happen in 2 cases - Secured Local card IDPROM read failed and authentication is not possible - There ACT2 Chip Acess(bus access problem) or Secured Certificate Errors), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_LOG_INT ### Response: (Severity: 3), (Category: SECURITY), (Description: Error description followed by logging integer.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-RX_ALARM_NO_SATELLITE_AVAILABLE_SYNC_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: The received and parsed GPS TOD message frame from external equipment indicates no satellite availablity, which could possibly indicate that the time-of-day received is not synchronized to a UTC/TAI timescale.), (Recommended Action: 1) Ensure GPS receiver connectivity on the external equipment.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCT_MA-3-BAD_MATCH_TYPE ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: An accounting policy-map must contain a class-map of type IPv4 ACL. This is the only supported match type.), (Recommended Action: Define a policy-map that contains an IPv4 ACL class-map. If issue persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_SYSDB_APPLY_BATCH ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occurred while checking for more SysDB batches after receiving request to shutdown the process. This may be due to resource starvation or an internal software programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*. The IS-IS process must be restarted before it can function correctly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-3-SFP_I2C_ACK_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Port controller driver detected I2C access error on SFP port.), (Recommended Action: Ensure that the SFP plugged-in is supported. If not, please replace the SFP. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the System Logging (Syslog) feature in Cisco IOS XR? ### Response: The Syslog feature in Cisco IOS XR is used for logging system messages related to network operations, errors, and security, aiding in network monitoring and troubleshooting. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-ASYNC_IPC ### Response: (Severity: 3), (Category: ROUTING), (Description: This message indicates that the BGP async ipc operation has error condition with the specified reason. BGP being an application of the AIPC services, it relies on the infrastructure to deliver it's ipc messsages, BGP will have recovery mechanism such as close the channel, or try to resend the message if it failed. Sometimes, this error can be 'normal' due to process restart, FO, or too much IPC messages cause IPC queues to be congested.), (Recommended Action: Some of the async ipc status is saved in the trace using 'show bgp trace aipc', and together with this message, it might be able to gather more inforamtion regarding this error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-4-FAIL_PACKAGE_CLEAN ### Response: (Severity: 4), (Category: INSTALL), (Description: Clean was not successfully completed.), (Recommended Action: This is a cleanup issue and has no impact on functionality.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-4-INVALID_SYSDB_ERROR ### Response: (Severity: 4), (Category: ROUTING), (Description: RIB recevied an unexpected error number from sysdb API.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-FIFO_0_OFLOW_FIA2BR_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: FIFO-0 FIA to bridge instance-3 overflow.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISK_DRIVER-3-FAILED_TO_OPEN_FILE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to open file to log debugs. If this failure occurs, debugs wont be logged.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LSPV_DPM-4-FAULT_NOTIFICATION ### Response: (Severity: 4), (Category: ROUTING), (Description: During an iteration of DPM a fault was detected. For more detailed information regarding faults, view 'show mpls oam dpm prefix fault'), (Recommended Action: Forwarding over the given prefix may not be deterministic nor stable. We recommend running 'show mpls oam dpm prefix fault' to determine all faults discovered thus far. If any are unexpected, review the control plane expectations and investigate the extent of the forwarding fault.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-3-INVALID_RECORD_MAGIC_NUM ### Response: (Severity: 3), (Category: OS), (Description: Invalid magic number), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR_API-6-CEMGBL_GOT_NOTIF_FROM_BCM ### Response: (Severity: 6), (Category: PLATFORM), (Description: Cemgbl got notification from BCM switch and displays the count and 1st index of it.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-TYPE6_MASTER_UPDATE ### Response: (Severity: 4), (Category: SNMP), (Description: SNMP configs are migrating due to change in the Type6 Master key. SNMP configs will not work during this migration.), (Recommended Action: This is just a warning message and No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-PHY_XAUI ### Response: (Severity: 4), (Category: L2), (Description: The XAUI bus between the PLA ASIC and PHY device experienced a synchronization problem resulting in a lane failure causing a link flap. A reset of the PHY device corrected the issue.), (Recommended Action: Software corrected the issue by power cycling the PHY device. If any loopbacks have been configured on the port, they may need to be re-configured.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_FIB_NPU-3-INT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message in the DNX FIB NPU to indicate that an internal error was seen when trying to check consistency of internal data structures.), (Recommended Action: Please collect the console log, FIB NPU traces (show cef trace loc <>), FIB NPU platform trace (show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_6_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias less than or equal to the low laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different ways to enable OSPF on an interface in IOS? ### Response: OSPF can be enabled on an interface in IOS using: 1) The ""network area"" command under the OSPF process 2) The ""ip ospf area"" command under the interface <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-2-MPLS_PREFIXOBJ_DELETE_FAIL ### Response: (Severity: 2), (Category: ROUTING), (Description: In lspnh delete prefix object(sdk) failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-UNEXPECTED_REQ ### Response: (Severity: 3), (Category: OS), (Description: Received unexpected message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-7-HANDLE_ADM1066_PROM ### Response: (Severity: 7), (Category: PLATFORM), (Description: This is a debug message to access adm1066 prom device through i2c. This CLI messages are printed when ADM1066 PROM is handled.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6-3-SYSDB_CONNECT_FAILED ### Response: (Severity: 3), (Category: IP), (Description: Could not connect to SysDB.), (Recommended Action: Restarting ipv6_io may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ_MGR-3-IMDR_ABORT ### Response: (Severity: 3), (Category: FABRIC), (Description: The FabricQ process aborted the iMDR upgrade most likely due to a prior process crash.), (Recommended Action: Examine logs to determine if the fabricq_mgr process crashes and collect relevant crash info. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PIFIB-7-DEBUG_CLEANUP ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when cleaning up debug.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRP_MAD-3-INVALID_MRPDU_PARSE_ATTRIBUTE ### Response: (Severity: 3), (Category: L2), (Description: An MRPDU packet has been received which MRP could not decode. The MRP infrastructure was unable to parse the packet correctly because certain fields are missing or truncated. The specific MRPDU will be dropped and the protocol will continue to operate. The message includes details of the position in the packet where parsing failed.), (Recommended Action: Use wireshark or another similar tool to verify the contents of the packet on the wire and ensure it is correctly formed. If the incoming MRPDUs are correctly formed, this error suggests invalid packet metadata. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE5_CODE_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE5_CODE_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-6-INFO_MAC_IF_SES_LIMIT_NOT_REACHD ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions from a particular MAC address on the given access interface is no longer exceeding the configured maximum.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to set up BGP dampening in IOS XR? ### Response: BGP dampening in IOS XR is set up to suppress flapping routes and reduce the instability they cause in the network. router bgp 65000 address-family ipv4 unicast dampening commit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-INITIFMGR ### Response: (Severity: 3), (Category: MGBL), (Description: 'Initialization of interface manager connection failed. The failure cause is mentioned in the error message displayed.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-LWM ### Response: (Severity: 3), (Category: MGBL), (Description: The LWM api call failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIV2_DM-3-INIT ### Response: (Severity: 3), (Category: L2), (Description: Driver manager encountered an error and is not able recover frm it. A reason text will be supplied. Call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-CONNECT_FAIL ### Response: (Severity: 3), (Category: QOS), (Description: Connection to IM server failed during QoS EA process init. This would lead to an inablility of QoS EA to process CAPS from QoS MA and to a potential disconnect between the hardware/software views of the configured qos policies on the system.), (Recommended Action: No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-SHM_INIT_FAILED ### Response: (Severity: 3), (Category: FABRIC), (Description: Initialization of shared memory for PLA has failed for atleast 10 times. This happens when there is failure in creating POSIX shared memory object.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel backup feature in Cisco IOS XR? ### Response: The MPLS TE auto-tunnel backup feature provides fast reroute protection for TE tunnels. It automatically creates backup tunnels for protecting TE tunnels based on the configured backup attributes. This feature is enabled using the 'mpls traffic-eng auto-tunnel backup' command in global configuration mode. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMDR-5-SHMEM_CREATE_FAILED ### Response: (Severity: 5), (Category: OS), (Description: shared memory creation in IMDR failed.), (Recommended Action: 'Restarting the process may resolve the issue.' 'If the problem persists after some tries, contact tac.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-STATS_SYNC_TOO_FAST ### Response: (Severity: 4), (Category: INFRA), (Description: When Linux networking 'statistics-synchronization' is configured, XLNCd polls IOS-XR interface statistics at the requested rate and sets the reported values in Linux. This message is displayed when one attempt to poll statistics had not completed by the time the next attmpt was scheduled, indicating that the system is unable to reliably deliver statistics to Linux as fast as requested. As a result, Linux interface statistics will temporarily not reflect the latest IOS-XR statistics. They will be updated with the correct values next time IOS-XR statistics are polled.), (Recommended Action: This message indicates that the system is unable to reliably deliver statistics to Linux as fast as requested. If it is only seen when the system is under high load then it may simply indicate a transient issue which is now resolved, and no further action is required. If it is seen repeatedly or when the system is not under load then you may need to reduce the rate at which statistics are delivered to Linux, by modifying the configured 'statistics-synchronization' polling rate, or the set of interfaces it applies to.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-6-PLUGGABLE_INFO ### Response: (Severity: 6), (Category: OS), (Description: An unexpected error occurred.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-4-DB_CLEANED_UP_PREMATURELY ### Response: (Severity: 4), (Category: L2), (Description: The database received a cleanup call before all interfaces had been deleted.), (Recommended Action: If any problems are seen, they may be rectified by restarting the edpl_ma process using the following command: - process restart edpl_ma) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSEC-6-INFO ### Response: (Severity: 6), (Category: SECURITY), (Description: IPSec Base component Informational message), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS LDP graceful restart feature? ### Response: The MPLS LDP graceful restart feature helps to minimize the impact of LDP session resets, allowing MPLS forwarding to continue uninterrupted while the control plane restarts. It preserves the MPLS forwarding state across the restart. It is enabled with the mpls ldp graceful-restart command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-CPU_MCERR ### Response: (Severity: 3), (Category: DRIVER), (Description: Card manager has detected that the CPU complex in the indicated card is reporting machine check error condition that is fatal and it will be auto reset to recover from the failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure LDP neighbor password? ### Response: To configure a password for an LDP neighbor, use the 'neighbor password' command under the MPLS LDP configuration. RP/0/RSP0/CPU0:router(config)#mpls ldp RP/0/RSP0/CPU0:router(config-ldp)#neighbor 192.168.1.2 password cisco123 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_REPAIR_BUNDLE ### Response: (Severity: 4), (Category: L2), (Description: When repairing the checkpoint structures for the bundle database an error occurred for named bundle and the bundle was not checkpointed. The next time an attempt is made to checkpoint the bundle it will fail and the checkpoint table will be reconstructed again, perhaps more successfully.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-4-VPWS_DUPLICATE_PEER ### Response: (Severity: 4), (Category: L2), (Description: For a P2P EVPN VPWS xconnect, next hop for the xconnect is learnt using EAD route received from the remote. Incase of Single Home, only 1 next hop for a xconnect can exist. An EAD will be considered duplicate under following conditions: (1) EAD routes with same Eth Tag ID(AC-ID), EVI & ESI as zero or different non zero ESI's are received from multiple peers. (2) An EAD route that is same as the local EAD within an EVI is received from atleast 1 peer.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-BAD_MSG_TYPE ### Response: (Severity: 3), (Category: SECURITY), (Description: Found an unsupported AAA message type in avlist.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COMMS-3-MY_SAVE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The client failed to save its own sequence data to Checkpoint. If the process restarts before the save is successfully retried, remote clients may get out of sync, and data loss could occur.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-RSPI_CAL_ECC_MBE ### Response: (Severity: 1), (Category: PLATFORM), (Description: RxSPI Calendar ECC multiple bits error.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_TX_TIMER ### Response: (Severity: 4), (Category: L2), (Description: An attempt to create or start a timer for periodic sending failed. Regular LACPDUs will NOT be sent out. This suggests that the line card is running low on system resources. Once some system resources have been released, the bundlemgr_local process should be restarted to retry the timer creation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLMGR_OBJ_LIB-6-RETRY_INPLACE ### Response: (Severity: 6), (Category: PLMGR_OBJ_LIB), (Description: Inplace modification for a given transaction is ongoing. This could happen if during inplace modification producer (policymgr) gets restarted and the client is not aware of it.), (Recommended Action: Wait until the current inplace modification is completed before attempting a new one.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-CFG_INCONSISTENT ### Response: (Severity: 4), (Category: L2), (Description: CFM recieved a configuration update that can not be processed because it is not consistent with the current internal state. The requested update will be rejected.), (Recommended Action: Restarting the process may help to resynchronize the system state. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FMGR-3-V6_SRC_CMPR_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Request to TCAM Manager for IPv6 src prefix compression failed. QOS policy on this interface will not take effect since TCAM entries are not programmed.), (Recommended Action: The QoS policy on this interface must be removed to free up other allocated hardware resources. Go to the interface and do 'no service-policy input | output ' 'commit') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-UBOOT_UPGRADE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error occured while uprading the uboot image. Cause of the error will be mentioned in the message displayed. The upgrade of uboot image will fail and could lead the card to be in inconsistent state.), (Recommended Action: Look for the error message and take necessary action mentioned in the error message. For eg, the upgrade is being attempted without putting the card in uboot mode. The message would suggest the user to put the card in uboot mode and proceed. If problem persists, do a card reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MKA-5-MACSEC_ENABLED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-RAW_PART_IO_MNT_LOW_MEM ### Response: (Severity: 3), (Category: MEDIA), (Description: Could not get enough memory while trying to initialize nvram.), (Recommended Action: 'Router running low in memory. Reboot if possible.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN-3-ALLOC_ARENA_FAILED ### Response: (Severity: 3), (Category: OS), (Description: SHMWIN failed to allocate the arena's virtual range from the server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture - show logging - show shmwin summary location 0/x/CPUx - show memory location 0/x/CPUx - show shmwin trace all location 0/x/CPUx) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the significance of using BFD in Cisco IOS XR? ### Response: Bidirectional Forwarding Detection (BFD) in Cisco IOS XR provides fast failure detection times for various network protocols, improving network stability and reducing downtime. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_CLIENT-3-AUTO_UPGRADE_CONFIG_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A failure has occured when applying FPD auto-upgrade configuration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LINK-5-CHANGED ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: The interface has changed state.), (Recommended Action: If the state change was unexpected, confirm the configuration settings for the interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-POWERRELOAD_RESET ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node is being reloaded on account of critical fault/alarm detected on the node.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_MPLS_EA-3-ERR_INIT_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in MPLS EA. Typically, this is an error where the software fails to initialize or programming of forwarding feature fails. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef mpls trace location <> show cef platform trace all all location <> show tech cef show version show install active summary show logging Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-6-CFG_SIZE_HIGH ### Response: (Severity: 6), (Category: SYSDB), (Description: The message to the user to indicate that the requested config size excceds the high end of the system memory limits), (Recommended Action: *RECURR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_LIB-4-LTRACE_INIT ### Response: (Severity: 4), (Category: INSTALL), (Description: Failed to register ltrace context structure. Tracing will not be functioning properly.), (Recommended Action: This indicates that the ltrace infrastructure could not be initialised. It only impacts ltrace message logging and has no impact on the functionality of the system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-ROUTER_ID_CONFLICT2 ### Response: (Severity: 5), (Category: ROUTING), (Description: This informational message appears as user-configured router-id of another BGP instance is the same as IPARM's default router id. User should change the router-id.), (Recommended Action: User should change the router-id.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHER_CTRL-3-OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHANCON-7-NO_PACKET ### Response: (Severity: 7), (Category: OS), (Description: Display index), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-TRAPEMPTY ### Response: (Severity: 4), (Category: SNMP), (Description: A trap destined for the given address was empty. This is an internal software error.), (Recommended Action: Restart snmpd process.if still noticed this message check the process 'show process snmpd' and contact technical support representative. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_1_XAUI_PLL_LOCK_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: NPU-1 XAUI PLL not locked on bridge instance-0.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_9_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-THREAD_CREATE_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Thread create failed.), (Recommended Action: None. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-5-NSR_SYNC_DONE ### Response: (Severity: 5), (Category: ROUTING), (Description: LDP Non-stop routing initial-sync event has completed successfully for some or all peers.), (Recommended Action: If number of peers do not match the number of peer for SYNC_START, then Check LDP logs and traces to see why not all attempted peers were successfully synced.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-EDM_REGISTER_FAILED ### Response: (Severity: 3), (Category: OS), (Description: The process failed when attempting to register its external data manager with SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMIO-3-OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-LIBENS_PRODUCER ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric FIA ENS library producer error), (Recommended Action: Report the error) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_HWOFFLOAD-4-LC_SCALE_LIMIT ### Response: (Severity: 4), (Category: PLATFORM), (Description: LC level scale limit has been reached.), (Recommended Action: All new sessions on this LC will be kept in ADMIN-DOWN state.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the 'install replace' command in Cisco IOS XR? ### Response: The 'install replace' command in Cisco IOS XR replaces the current software with a new version, effectively performing an upgrade or downgrade of the system software. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SSP_INTR_SFIFO_FULL_IF1_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SSP_INTR_SFIFO_FULL_IF1 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-EVENT_CONN_NOTIFY ### Response: (Severity: 7), (Category: INSTALL), (Description: The library failed to register for notifications on a connection.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TZ-3-PUF_MEDIA_ACCESS_ERR ### Response: (Severity: 3), (Category: OS), (Description: There indicated media cannot be ccessed to read/write timezone configuration file.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What features of IOS XR BGP help improve convergence times? ### Response: Several features help improve BGP convergence times in IOS XR: 1) Update groups allow efficient generation and transmission of BGP updates by grouping neighbors with the same outbound policy. 2) Best-external route injection allows the router to advertise the best route learned from an eBGP neighbor back to another eBGP neighbor, thus providing faster convergence than if the route had to be learned via an iBGP neighbor. 3) Add-path allows the router to advertise multiple paths for the same prefix, thus providing faster convergence in the event of a path failure. 4) Next-hop tracking allows the router to track the reachability of the next hops of BGP routes, thus providing faster convergence if a next hop becomes unreachable. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different options for connecting a CE router to a PE router in an L3VPN? ### Response: There are several options for connecting a CE router to a PE router: 1) Static routing, where the CE-PE routes are manually configured on both routers. 2) eBGP, where the CE and PE routers run eBGP to exchange routes. 3) OSPF, where the CE and PE routers run OSPF to exchange routes. The PE router redistributes the OSPF routes into MP-BGP. 4) RIP, where the CE and PE routers run RIP to exchange routes. The PE router redistributes the RIP routes into MP-BGP. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_10_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-CPM_REG_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to failure of registration with CPM. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WD_MEMMON-6-MEM_NORMAL ### Response: (Severity: 6), (Category: INFRA), (Description: Memory usage is below minor threshold, state is NORMAL.), (Recommended Action: Nothing required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-6-ACTION_COMPLETE ### Response: (Severity: 6), (Category: INFRA), (Description: A user requested install operation has completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_TOPAZ-7-ERR_EVM_CREATE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while attempting to create an event manager. This failures affects the ability of the process to service various messages / pulses from other threads / processes. This facility is deemed crucial and the process automatically restarts on this failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-NO_MEMORY ### Response: (Severity: 3), (Category: OS), (Description: QSM could not obtain system meory while performing the indicated operation.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_1_ERR2_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 1 ran into error-2 on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-7-RESTORE ### Response: (Severity: 7), (Category: SYSDB), (Description: If an EDM registers or reregisters on a path on which items already exist (and SYSDB_REGISTRATION_OPTION_SCAN has been specified), then those items have been deleted but not all restored after the EDM registration, so the system may now be in an inconsistent state.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-DRIVER_READY_TIMEOUT ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC driver running on the indicate card did not finish the basic initialization operation in time. PM will attempt to recover from this failure condition by restarting CCC driver multiple times. If after 5 times CCC driver still can't complete basic initialization, Then the SysAdmin VM will be restarted as another attemp to recover from this failure condition.), (Recommended Action: If SMU installation triggered this failure condition, try to remove the SMU and then reimage the card to recover from this failure condition.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure a logging host? ### Response: To configure a logging host for syslog messages, use the 'logging' command in global configuration mode. RP/0/RP0/CPU0:router(config)#logging 192.168.1.100 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-ETHERENCAP ### Response: (Severity: 3), (Category: ROUTING), (Description: The MAC address length provided for the ethernet encapsulation is wrong.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-SYSTEM_CALL_TIMEOUT ### Response: (Severity: 6), (Category: OS), (Description: This syslog msg is printed out when a system call blocked too long, and is unblocked forcibly by internal timeout mechanism. This msg logs the timestamp when the timer started last time, and the timeout value specified for that.), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD_inv-6-UNPAIRED_DRP ### Response: (Severity: 6), (Category: HA), (Description: This is an informational message output during SDR configuration commit time only if an unpaired DRP node is being assigned to an SDR.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SCAN_REGISTERS_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Core dump failed because scanning registers for the process failed. This will impact the core file and the context file.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_IO-7-ERR_IM ### Response: (Severity: 7), (Category: ROUTING), (Description: Some error occurred in operations with IM. The text of the message displays the failed operation and the related error code. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: sIMP-4-MSG_WARN ### Response: (Severity: 4), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-LSP_BW_CHANGE ### Response: (Severity: 5), (Category: ROUTING), (Description: The signalled bandwidth on the specified tunnel interface has changed.), (Recommended Action: None. This is a solicited message (by 'logging event lsp-status bw-change'\ interface configuration) and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-INTERNAL ### Response: (Severity: 3), (Category: SNMP), (Description: General internal failure. This is likely an internal software error.), (Recommended Action: If there is a crash/deadlock, you may need to collect logs from 'show process blocked' and 'run attach_process -p ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-SR_ULOOP_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured while processing something related to a global micro-loop avoidance This is a fatal error related to the global microloop avoidance and hence we will not be able to perform the microloop avoidance functionality, at least for the latest topology cahnge interface that is being), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-INTERNAL_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error happened, this may be due to an internal programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_OTN_OOF ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-OUT_OF_MEMORY ### Response: (Severity: 3), (Category: ROUTING), (Description: Eliminate system processes or add memory), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show processes msdp detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes msdp detail output, call your Cisco technical support representative and provide the representative with the gathered information. Using the Job ID from the above command, please run the following command: Copy the error message exactly as it appears on the console or in the system log. Issue the show processes memory command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes memory output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show memory summary command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show memory summary output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-CDM_OPEN ### Response: (Severity: 3), (Category: OS), (Description: Unable to open a CDM table.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_RIB-3-ERR_BUF_NEVER_FITS ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered RIB buffer can not handle single route.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SC_CARD_VOLTAGE_FAULT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Shelf controller observing voltage fault/fluctuation.), (Recommended Action: This condition indicates potential votlage fluctuation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-0-NP_OOR_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: NP system resources have been exhausted and cannot be recovered), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPP_PKT_F2_FULL ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPP packet FIFO 2 full.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LWMESS-7-UNLOCK_CONN ### Response: (Severity: 7), (Category: OS), (Description: The mutex for the channel connection list could not be released), (Recommended Action: This is an internal error and should be reported to TAC. Try re-starting the offending application. If that does not work, a memory dump should be taken (to assist TAC) and the router should be rebooted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-1-CARB_FIL_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Fabric arbiter driver detected a carb filter error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_FILERESTORE ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-7-ERR_SYSDB_FD ### Response: (Severity: 7), (Category: SECURITY), (Description: Error encountered while using the System Database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_AUTO_TUN_MESH_TUN_DEST_LIMIT_EXCEEDED ### Response: (Severity: 3), (Category: ROUTING), (Description: The creation of the auto-mesh tunnel aborted since it would have exhausted the tunnel destination scale limit), (Recommended Action: Reduce configured/auto tunnels to below the system scale limit) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_NETIO-5-SET_MAPPING_FAILED ### Response: (Severity: 5), (Category: ROUTING), (Description: MPLS could not set control mapping for underlying protocol.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSD_ENC-1-INSTALL_TRANS_IN_PROGRESS ### Response: (Severity: 1), (Category: OS), (Description: An Install transaction is in progress. Encryption operation cannot continue.), (Recommended Action: Wait for install transaction to complete before requesting the encryption operation again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-5-NBRCHG ### Response: (Severity: 5), (Category: ROUTING), (Description: PIM neighbor state change message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLCTRLR-4-FEAC ### Response: (Severity: 4), (Category: L2), (Description: New Far End Alarm Code received.), (Recommended Action: No Action Required) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: T1E1-2-NOMEM ### Response: (Severity: 2), (Category: L2), (Description: The process is out of memory. Unable to initialize memory for add/del queue for add or del channel group request.), (Recommended Action: Check process list for source of memory loss. Check if h/w memory requirements are met. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-3-ERRDIS_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The port should have been Error Disabled, but an unexpected error has prevented it from being shut down. The port is still up, and will not be disabled.), (Recommended Action: Shutdown the port manually if it is still desirable to bring it down. Otherwise, no action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-3-EVM_CREATE_FAILED ### Response: (Severity: 3), (Category: IP), (Description: The IPv4 MA process could not create the event manager to handle the events to be received by the process. This can happen when the process is (re)starting. The process recovers by restarting itself. If the error message doesn't persist, it can be ignored. If the error message persists, some basic ipv4 functionality may not be available.), (Recommended Action: Collect the output of show tech-support, show processes, show ipv4 ma trace from the location the error message comes from. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRP_MAD-3-INVALID_MRPDU_PAYLOAD ### Response: (Severity: 3), (Category: L2), (Description: An MRPDU packet has been received but the contents of the packet cannot be determined. This is due to packet metadata fields set by the platform being invalid. The specific MRPDU will be dropped and the protocol will continue to operate.), (Recommended Action: Use wireshark or another similar tool to verify the contents of the packet on the wire and ensure it is correctly formed. If the incoming MRPDUs are correctly formed, this error suggests invalid internal packet metadata. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH-6-EOBC_CHIP_DOWN ### Response: (Severity: 6), (Category: PLATFORM), (Description: Hooper chip shows the register reading 0xffffffff. Recovery action may take place.), (Recommended Action: 'show controllers epm-switch port-mapping location *') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPIO_PD-3-EA_LTRACE_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Trace initialization failed in packet programming path. Packet path initialization is aborted and may be retried.), (Recommended Action: Restart the protocol process. 'process restart location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WDMON_LIB-3-IOFPGA_WATCHDOG_PUNCH_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: Error occurred in HW watchdog punching logic due to which watchdog punching has stalled. Card will reload if the system is unable to correct this condition on its own.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-NODE_BOOT_OPTIONS_CLEAR ### Response: (Severity: 6), (Category: INSTALL), (Description: The boot options of the specified node are cleared when the node preparation is complete.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN-3-FTRUNCATE_FAILED ### Response: (Severity: 3), (Category: OS), (Description: SHMWIN encountered an error condition, the ftruncate failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture - show logging - show shmwin trace all location 0/x/CPUx) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_IPV4_EA-3-CRITICAL ### Response: (Severity: 3), (Category: PLATFORM), (Description: SSE IPV4-EA, Critical error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-SATELLITE_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An error has occurred on the satellite.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTT2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_MDM-3-METADATA_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: The process is exiting, due to Failure in CPP Infra Metadata Mgr.), (Recommended Action: *SH_CMD show controllers pse qfp infrastructure metadata location < > *) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-5-MAP_SERVER_REGISTER_ALLOWED_LOCATOR_MISMATCH ### Response: (Severity: 5), (Category: IP), (Description: 'The map-register contains RLOC that is not in the site's ' 'allowed locator list.'), (Recommended Action: 'Ensure map-server has the registering RLOCs ' 'added to the site's allowed locator list.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_HEAP-7-MUNMAP ### Response: (Severity: 7), (Category: HA), (Description: When attempting to free memory that is no longer in use, the checkpoint library received an error from the kernel.), (Recommended Action: Collect system log information and forward to technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-4-BUS_WARNING_THRESHOLD_EXCEEDED ### Response: (Severity: 4), (Category: PLATFORM), (Description: A device has been detecting a PCIe bus error and it is exceeding threshold. The message has the device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-3-SCRATCH_TEST_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The CPU at the failed location has failed to access the named device scratch register.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_7_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-3-CBC_UART_FILE_DESC ### Response: (Severity: 3), (Category: PLATFORM), (Description: Informational log only), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB_LIB-2-OOR_PROC_RESTART ### Response: (Severity: 2), (Category: L2), (Description: The l2fib_mgr process on the node has detected that a process required to handle updates is restarting. Normal operation will resume once the process has restarted.), (Recommended Action: Normal operation should resume automatically, once all resources are declared available again; to know the current status of l2fib_mgr's resources, use the command 'show l2vpn forwarding resource location <>'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-UNUSABLE_TUNNEL ### Response: (Severity: 4), (Category: ROUTING), (Description: TE or XTC has sent an unusable tunnel to ISIS), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT_SWITCH-3-LINK_FAIL_7 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Punt link failed), (Recommended Action: Please correct the error by performing card reload using command: 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-NODEID_FAIL ### Response: (Severity: 6), (Category: OS), (Description: Failed to get the local nodeid from platform library.), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SUB_UTIL-3-THROTTLE_INTERNAL ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: Subcriber Session Flow control Infra init encountered unexpected error, so the sesison flow control feature is not enabled.), (Recommended Action: Please collect the following logs when this ios message is seen. 'show subscriber infra readiness trace process ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-MBIST_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates possible fault with the NP internal memory.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM_PD-3-DLL_INIT_FAIL ### Response: (Severity: 3), (Category: L2), (Description: A failure occurred during the initialization of the platform dependent adjacency programming DLL. This will result in the hosting process being restarted. This condition can occur while : 1. Trying to get the host Event Manager 2. Initializing the debug library), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-ADD_SESSION ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to add_session() was unsuccessful'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-3-CALLOC_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: --), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-MEM_ALLOC_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The requested operation could not be accomplished because of a low memory condition. This error could impact Linux/Application image download and Launch, Services PLIM IPC (Inter Process Communication) etc.), (Recommended Action: Reduce other system activity to ease memory demands, then restart the process. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-4-RESYNC_FAILED ### Response: (Severity: 4), (Category: OS), (Description: A Linux Packet classifier instance running on a LC node failed to resynchronize its Linux socket database with the master version on the RP, after multiple retry attempts. It will continue to retry, but the Linux packet path may experience disruption until the resynchronization is complete.), (Recommended Action: Periodic attempts to connect will continue to occur. This condition may be expected in scenarios where nodes are brought up and down (e.g. ISSU or RP failover). If this message continues to be seen outside those scenarios, it may indicate a problem with GSP. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKWATCH-6-INFO_BODY2 ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: The resource depletion information in the following format: PROGRAM_COUNTER COUNT), (Recommended Action: It is an informational message along with packet depletion log message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTF_EA-3-RELOAD_LC ### Response: (Severity: 3), (Category: PLATFORM), (Description: The LC needs to be reloaded for the configured qos shaping granularity to be applied.), (Recommended Action: Exit the Config-terminal. Reload the Linecard using 'hw-module location reload' option.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-SET_TARGET_NODE_FAIL ### Response: (Severity: 3), (Category: SYSDB), (Description: An error occurred during sysDB health check. Not able to set the remote target node on which the health check needs to be done.), (Recommended Action: In most cases, this would be transient error. However, if this happens repeatedly, please collect 'show tech sysdb'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-7-INFO ### Response: (Severity: 7), (Category: PLATFORM), (Description: Information message from Discovery driver on software error condition.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEM_PLATFORMS-2-ERR_HEX ### Response: (Severity: 2), (Category: L2), (Description: Error in cem operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-ASYNC_IPC_STATUS ### Response: (Severity: 5), (Category: ROUTING), (Description: This notice message indicates that the BGP async ipc operation has an important status change, such as connection is up or down, or the instance has received all the initial configurations from BPM.), (Recommended Action: This is in most cases informational only, and are part of the normal operation such as process is up, or RP switched over, etc. But this message can also be used to assist debugging bgp configuration related async ipc issues.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-EVENT_BLOCK_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_HT0_PROTO ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an HTDP protocol error on the HT0 interface. This is logged when the HT interface experiences a protocol error on the HT interface.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-EVENT_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: This system encountered an error while trying to get an event from the event handler.), (Recommended Action: Restart of EIGRP might solve the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-0-SEM_UNCORR_ERR ### Response: (Severity: 0), (Category: PLATFORM), (Description: Egress Mux FPGA has encountered uncorrectable error. Reloading LC to recover.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-ERROR_MSG ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is a debug message in the NP Driver to indicate an operation or condition.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-IGPS_MODE_NOT_SUPPORTED_IN_HARDWARE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The synchronization port 3 is for Internal GPS but Internal GPS is not Supported on this platform), (Recommended Action: Do not attempt to configure RP clock interface 3) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-SRMS_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: The IS-IS process failed to initialize the service for the specified error reason.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-EVM ### Response: (Severity: 3), (Category: ROUTING), (Description: A call to an external event manager function failed. The impact of this error is insignificant, unless the error condition persists for a duration close to the minimal DeadInterval used over all OSPFv3 interfaces.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospfv3 - show ospfv3 trace all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel backup affinity feature? ### Response: The MPLS TE auto-tunnel backup affinity feature allows auto-tunnel backup tunnels to select or avoid links for the backup path based on configured affinity attributes. This provides more control over the backup path selection compared to the default behavior of using the IGP shortest path. Affinities allow backup paths to be optimized for specific requirements. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CBC-3-CANBUS_A_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: CBC detected CANBUS A failure. This may be a serious failure, however the system may continue functioning as expected despite the failure.), (Recommended Action: Reboot the LC. If the problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-FEEDBACK_OUTSIDE_RANGE ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the nsf ietf command in IS-IS? ### Response: The nsf ietf command is used to enable IETF-standard Non-Stop Forwarding (NSF) for IS-IS. Like Cisco NSF, IETF NSF allows the router to continue forwarding traffic during a supervisor switchover or a software upgrade. However, it uses a different mechanism for synchronizing the database with neighboring routers after the switchover or upgrade. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_4_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_4 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-EVM_TM_DETACH ### Response: (Severity: 3), (Category: HA), (Description: An internal error was detected when trying to remove a managed timer registration from an event manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What information is contained in an OSPF hello packet? ### Response: An OSPF hello packet contains the router ID, area ID, network mask, hello interval, router dead interval, router priority, DR/BDR IP, and a list of neighbors seen. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AIB-4-LTRACE_ERROR ### Response: (Severity: 4), (Category: ROUTING), (Description: AIB process was unable to open the trace buffer use to record its activity for diagnostic purposes. The 'show trace adjacency' command may not work. The process will attempt to recovery by restarting. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: This shows that there are underlying system level problems, so review all recent unsolicited errors. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-4-REMOTE_SESSION_STOP_FAILED ### Response: (Severity: 4), (Category: L2), (Description: A request was made to stop a remote loopback session, but either no response was received, or a response was received indicating that the request failed.), (Recommended Action: No action is necessary, as the session will eventually time out. Further requests can be sent to retry the stop attempt if desired.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-STATE_CHANGE_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: An unknown error was encountered saving state at the end of a successful operation. Further install actions may error if state is inconsistent. A system reload may be required to recover.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: C_SHIM_PARTNER-3-CAP_ADD_ERR ### Response: (Severity: 3), (Category: L2), (Description: 'There is an error when adding batched channelized interface caps.'), (Recommended Action: Please try to reload that particular SPA or restart the SPA process associated with that SPA. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR support in-service software upgrades (ISSU)? ### Response: Cisco IOS XR supports ISSU by allowing software upgrades without interrupting the router's operation, ensuring continuous network service during the upgrade process. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-HIGH_POWERED_PLIM_NOT_POWERED_ON_IN_LOWER_BAY ### Response: (Severity: 4), (Category: PLATFORM), (Description: High Powered PLIMs in the lower slot (s = 8..15) may only be powered on if there is an High Powered PLIM powered on in the paired upper slot (slot = s-8) or if the paired upper slot is empty.), (Recommended Action: Insert the High Powered PLIM in an upper slot (s = 0..7), or in the lower slot(s = 8..15) where the slot above it(slot = s-8) is either empty or having an High Powered PLIM.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-DDR_BUS_BIT_STUCK_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: DDR bus databit stuck on bridge instance-1.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-NOTIF_HANDLE ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when trying to handle a notification from the respective component.When this issue happens, it will trigger an automatic restart of pifibm_server_lc process), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C_SERVER-3-GN2412_CONF_TIMEOUT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The GN2412 retimer chip that amplifies the voltage to line cards in the lower half of the shelf could not be configured due to timeout.), (Recommended Action: 1) process restart i2c_server location < active RP location> 2) if 1 doesnt help , reload the RP) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMORB_XMLAGENT-3-CRYPTO_INIT ### Response: (Severity: 3), (Category: MGBL), (Description: The crypto pie is not properly configured and can't be initailized), (Recommended Action: Configure crypto according to crypto setup procedures) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-4-CERT_DOESNT_MATCH_ID ### Response: (Severity: 4), (Category: SECURITY), (Description: Peers claimed identity doesn't match what we can glean from the certificate.), (Recommended Action: 'Contact remote peer and/or his administrator if session doesn't come up') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-6-SETSOCKOPT_FAULT ### Response: (Severity: 6), (Category: IP), (Description: An error occurred whilst trying to setsockopt on the socket. Session will continue.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_1_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_CONFIG-7-LTRACE_INIT_ERROR ### Response: (Severity: 7), (Category: OS), (Description: ltrace initialization for ltrace config failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XFP-3-LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected an XFP temperature less than or equal to the low temperature warning threshold. The XFP is the pluggable optics on the line cards. The temperature threshold values are read from the XFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the XFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: 10GE_PLIM-6-ERR_UPGRADE ### Response: (Severity: 6), (Category: L2), (Description: This is a Informational message in the plim_8p_10ge driver to indicate an operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-READERINIT ### Response: (Severity: 4), (Category: MGBL), (Description: An error occurred while preparing to read instructions from the command line.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-NON_HIGH_POWERED_PLIM_NOT_POWERED_ON_IN_UPPER_BAY ### Response: (Severity: 4), (Category: PLATFORM), (Description: Non High Powered PLIMs in the upper slot (s = 0..7) may only be powered on if there is no High Powered PLIMs powered on in the paired lower slot (s+8).), (Recommended Action: Insert the Non-High Powered PLIM in a lower slot (s= 8...15), or in the upper slot (s = 0...7) where there is no High Powered PLIM in the lower slot (s+8).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-ALL_FANTRAYS_MISSING_CLEAR ### Response: (Severity: 2), (Category: PLATFORM), (Description: One or more fan trays plugged into the chassis, chassis cooling is now in operation. One fan tray runs at full speed by SW default and provides partial chassis cooling, two fan trays run at computed speed based on ambient temperature.), (Recommended Action: Give CLI: (admin)# show env --> all sensor output (admin)# show env trace (exec)# show env led details Specifically look at temperature and fan speed sensors output, fan speeds initially adjust to their computed speed given the ambient temperature and then as ambient temperature drops, the fan speeds continue to adjust downward until reaching steady ambient temperature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-3-TEST_FAIL ### Response: (Severity: 3), (Category: DIAG), (Description: A diagnostic test has found an error on the line card.), (Recommended Action: Ensure the line card is firmly in the slot, reseat if necessary, and attempt to run the test again if the line card is not seated properly in the slot. If the line card was properly seated in the slot, copy the error message exactly as it appears on the console, gather the output of show tech-support, and contact your Cisco technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRLLIB-3-DETECTED_CDMA_PORT0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cpuctrl driver detected an attempt to DMA to port 0. The request was discarded and not performed. %d - channel number %d - queue number %s - client name %x - address high 32bit %x - address low 32bit), (Recommended Action: Investigate the client that attempting the DMA access No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_400G_POD-3-TX_CH_LO_PWR ### Response: (Severity: 3), (Category: FABRIC), (Description: The POD detects a low power on a channel. The channel may not be functioning properly, and can cause cell drops, or corruption in the downstream. This is a precursor to the Tx LOS.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA_CAPI_SERVER-3-IOFPGA_INTR ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_SIM-3-BATTERY_LOW ### Response: (Severity: 3), (Category: MEDIA), (Description: Detect NVRAM low battery state, the data stored in NVRAM may be destroyed after power down the board whit battery low state.), (Recommended Action: 'NVRAM Battery may need to be replaced') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-3-STARTUP_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: locald process failed to startup properly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEATURE_AGENT-4-INVALID_UPDATE ### Response: (Severity: 4), (Category: INFRA), (Description: Feature Agent received a support or use value for an unexpected feature from the identified process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_FPGA-3-LTRACE_INIT ### Response: (Severity: 3), (Category: L2), (Description: --), (Recommended Action: Typcially these indicate that ltrace is out of service. check at other processes using ltrace and see whether the problem happens to them.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ACL-1-IPACCESSDLLOPEN ### Response: (Severity: 1), (Category: ACL), (Description: This message is seen when the process fails to open the DLL 'libipv6_acl_tree.dll'. This failure may occur on RP and LC. It may fail to open the DLL due to any one of the following reasons: 1. passing the bad mode like no share mode(RTLD_NOSHARE) 2. list of DLL objects is empty or the list itself doesn't exits. 3. if no symbol in executable. 4. if the memory allocation fails at any stage 5. if the dll is not unique with respect to the other DLL's loaded and placed in the list.), (Recommended Action: This message may occur during process initialization. Please try restarting the process that issued this error message with the command. process restart location . Process name should be printed in the message already.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-1-UC_HI_MBE_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Unicast high priority fifo multi-bit ECC error), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-2-SCRATCH_MPA_TEST_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: The CPU at the failed location has failed to access the named device scratch register.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INVMGR-5-OIRIN ### Response: (Severity: 5), (Category: PLATFORM), (Description: Entity specified in the messages is inserted into the chassis and inventory manager is updated.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMATTR-3-NOTIFY_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The attribute owner library has failed to send a bulk notification message to the attribute clients. However, the attribute owner that produced these notifications is not aware that they failed to be sent. This could result in the attribute clients being out of sync with this owner.), (Recommended Action: If the system appears to be in a low-memory condition (check the output of 'show mem summary') then this is most likely the cause of the problem. Please try to fix the low-memory condition. If this is not the case, then contact technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-4-REMOTE_SESSION_START_FAILED ### Response: (Severity: 4), (Category: L2), (Description: A request was made to start a remote loopback session, but either no response was received, or a response was received indicating that the request failed.), (Recommended Action: Further activate requests may be sent to retry the session start. If no responses were received, this may indicate that latching loopback is not permited at the target address.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does LPTS classify and police traffic flows to the router? ### Response: LPTS classifies traffic flows based on various packet header fields like source IP, destination IP, protocol, ports etc. It then assigns the flows to one of several pre-defined flow types. Each flow type has a configured rate limit. Packets exceeding the rate limit are dropped. This protects the router resources from being overwhelmed. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SGT_HDR_EXT_FIFO_OFLOW_1_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress sgt hdr ext fifo overflow on xaui-1 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-6-bridge_oor ### Response: (Severity: 6), (Category: L2), (Description: Bridge table OOR during bridge creation event), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_AGG-7-ERR_LTRACE_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: The FGID Aggregator Could not open the annunciated ltrace buffer. The FGID component and the system should still function as normal, with the exception that ltrace will not be available for fgid_aggregator process.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6-3-EDM_OPEN_FAILED ### Response: (Severity: 3), (Category: IP), (Description: While processing the indicated show command, the ipv6_io process could not connect to the SysDB server.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-4-STARTUP_FILE_OPEN_WRN ### Response: (Severity: 4), (Category: MGBL), (Description: Failed to open the startup configration file for any of the following reasons: - file does not exist. This may be case when booting for the first time or when even the default startup config file does not exist. IGNORE the message in this case. - CONFIG_FILE is set to a directory. - the config file doesn't exist under the current directory. - Illegal file name. set CONFIG_FILE to a valid file name an retry. - Other system errors. The last part of the error message should give a hint of the system error.), (Recommended Action: Since the startup configuration file cannot be opened, no run time configuation will be available. Make sure a startup config file exists somewhere and CONFIG_FILE points to it. Run copy running-config startup-config) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PM-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: svc pm encountered a fatal error and is not able to recover from the error. A text reason and error number will be supplied to describe the error.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect 'show log location ' output, and 'show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-DUPLICATE_INTF ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: XR and Linux interfaces specified in XR_INTERFACES must be unique.), (Recommended Action: Check for duplicate interfaces in the XR_INTERFACES environment variable.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-tunnel primary feature? ### Response: The MPLS TE auto-tunnel primary feature enables the automatic creation of primary MPLS TE tunnels between tunnel head-end and tail-end routers. It simplifies the provisioning of TE tunnels by automatically creating them based on a template configuration. Auto-tunnels are created to next-hop routers learned via IGP. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SGT_FIFO_OFLOW_0_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress sgt fifo overflow on xaui-0 bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-invalid_frag_filter_combo ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This message will typically occur when an ACE is specified when multiple fragment filters are specified in an ACE of an attached ACL that are mutually exclusive.), (Recommended Action: Make sure that the only one of the fragment filter is specified.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-ERR_SERVICE_CONN_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: NPU driver failed to connect to the identified service during the driver initialization. The driver will be non-operational due to this error.), (Recommended Action: The driver will escalate the error to the Fault Management (FM) entity for further action. Verify that the driver will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-7-REFERRAL_COUNT ### Response: (Severity: 7), (Category: SYSDB), (Description: An internal library error has caused a connection attempt from a client to SysDB to fail.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-3-TSP_B_PKT_DECODE_DIS ### Response: (Severity: 3), (Category: PLATFORM), (Description: TSP decoder B disabled but packet received.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMDR-5-SHIP_REG_PERFORMANCE_COUNTERS_FAILED ### Response: (Severity: 5), (Category: OS), (Description: 'Ship registration for performance counters failed.' 'Ship functionality may not work properly.' 'IMDR will proceed without fail.'), (Recommended Action: 'Restarting the process may resolve the issue.' 'If the problem persists after some tries, contact tac.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACE_GRP-3-ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: An error occurred in ace_grp dll), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-6-ID_CERT_RENEW_SUCCESS ### Response: (Severity: 6), (Category: LICENSE), (Description: Customer ID cert has been renewed successfully and can continue to use the device.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QAD_SERVER-3-ERROR ### Response: (Severity: 3), (Category: OS), (Description: The specified operation failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCFIND-4-NODETYPE ### Response: (Severity: 4), (Category: OS), (Description: Procfind was did not recognise the node type on which it was running, and therefore assumed it was a linecard.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-3-ECM_RETRY_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The specified process encountered an error while attempting to schedule a retry for a failed operation. The operation will not be retried. This may indicate that system resources are low.), (Recommended Action: Attempt to resolve any memory issues before attempting to solve this problem. After system resource isses have been resolved, issue 'process restart' on the affected node. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RASF-2-NO_COMPARE ### Response: (Severity: 2), (Category: ROUTING), (Description: This is a logic error in the construction of one of the ORA entities. A compare function was missing at the 'per route' level of detail.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCMD-6-NTP_DRIFT ### Response: (Severity: 6), (Category: ROUTING), (Description: Provides information about the NTP time drift in RCMD.), (Recommended Action: This is for information only. It indicates RCMD detects the NTP time drift. There might be some inconsistent data in RCMD. Please restart RCMD Server Process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-FIT_HARD_RESET ### Response: (Severity: 6), (Category: FABRIC), (Description: This indicates that the FIT tool has forced/induced a hard reset.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-HEAP_CORRUPT ### Response: (Severity: 3), (Category: OS), (Description: --), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-7-INIT ### Response: (Severity: 7), (Category: L2), (Description: Initialization of packet filter process has failed due to one of the following reasons: 1) Failed to initialize event manager. This would prevent process from receiving events. 2) Failed to initialize SSE Pfilter EA Library. This would prevent process from doing any of its tasks. 3) event_block failed. This indicates process has encountered unexpected error while waiting for events.), (Recommended Action: No action is required. Process will be restarted. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FHRP_OUTPUT-3-ERR_CLIENT_OUT_OF_SYNC ### Response: (Severity: 3), (Category: IP), (Description: The FHRP Output process Packet thread was unable to signal to the Main thread to request a resync with an FHRP protocol and is now out of sync. Process restart may be required to recover.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD-3-CHKPT_SAVE_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: FWD encountered an error while checkpointing interface info. While this will not affect present service, it will affect CPU bound fwding if partner process restarts.), (Recommended Action: If any traffic is affected after partner process restart, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_FI_INTR_RCTL0_LO_OVERRUN_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_FI_INTR_RCTL0_LO_OVERRUN interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_lite-3-ERR_SHMEM_MMAP_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Attempt to mmap the shared memory fails), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-BF_MBE_ERR_FIA10 ### Response: (Severity: 3), (Category: PLATFORM), (Description: FIA10 burst FIFO multi-bit error.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDLD-3-ERROR_LINK_NOT_DISABLED ### Response: (Severity: 3), (Category: L2), (Description: A failure occurred when attempting to error disable an interface after a fault condition was detected on the interface by the UDLD protocol. This will result in the interface remaining up, when it should be shut down.), (Recommended Action: The link can be disabled manually by configuring shutdown on the port. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-DEC_A_PWM_ERR_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: PWM bit level decoder error on decoder A on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MLIB-3-EVENT_CONN_MGR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-MISSING_OR_WRONG_ROLE_CONFIG ### Response: (Severity: 3), (Category: PLATFORM), (Description: Services role configured. without this card will never come up.), (Recommended Action: Check hw role config ('show run | i hw-mod'). Configure correct role and reload the LC ('hw-module location reload').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_PM_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Satellite PM Failure (SAT_PM_FAIL) alarm is raised when there is a faulty power-supply assembly.), (Recommended Action: If the problem persists, call your technical support representative for fan tray repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_TE_PREFIX_ADD ### Response: (Severity: 4), (Category: ROUTING), (Description: The process encountered an error while sending a prefix to TE.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-2-REPLACE_BOARD ### Response: (Severity: 2), (Category: PLATFORM), (Description: This board is using a Discovery system controller and hence the board needs to be replaced.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-TX_ALARM_TAF ### Response: (Severity: 3), (Category: PLATFORM), (Description: Condition raised possibly due to incorrect internal BITS transmitter configuration.), (Recommended Action: Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-HA_WAIT ### Response: (Severity: 3), (Category: OS), (Description: An internal cpp_ha_platform_wait_for_platform_state function still waiting for HA redy state.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-TABLE_OPERATION_FAIL_GLACIAL ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_HW_OFFLOAD-4-MODE_CHANGE ### Response: (Severity: 4), (Category: PLATFORM), (Description: bfd hw offload mode changed, config will be activated only after a line card reset), (Recommended Action: config will be activated only after a line card reset. Reboot the LC during the next maintenance window.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM_PLATFORM-3-BAD_READ_WRITE ### Response: (Severity: 3), (Category: MEDIA), (Description: Read/Write Failed), (Recommended Action: 'Check the Buffer Length') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_TOPO ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error encountered in RIP's topology module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-EDM_INIT_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure LDP address withdrawal? ### Response: To configure LDP address withdrawal, use the 'address withdraw' command under the MPLS LDP configuration. RP/0/RSP0/CPU0:router(config)#mpls ldp RP/0/RSP0/CPU0:router(config-ldp)#address withdraw <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWRMON-2-MODULE_WARNING ### Response: (Severity: 2), (Category: PLATFORM), (Description: 'Either a feed voltage out of limits warning, unit in current/power limit or over temperature warning condition.'), (Recommended Action: Try restarting the using CLI command in exec mode - process restart pwr_mgmt If the error exists try -insert and re-insert the PM If the error exists - Replace the power module) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-HARD_RESET_FIA ### Response: (Severity: 4), (Category: PLATFORM), (Description: The FIA Driver as requested the NP Driver to perform a hard reset as a recovery action for a FIA fault.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA_MGR-3-UPGRADE_NOT_SUPPORTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: The indicated FPD upgrade is not supported on this platform due to the reason displayed by the platform error message.), (Recommended Action: Follow the platform message to enable the FPD upgrade on this platform) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_A9K_LC_SVI-2-VQI_ERROR_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Unable to obtain VQI.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-2-ARCHIVE_THRESHOLD_CROSSED ### Response: (Severity: 2), (Category: OS), (Description: Syslog archive size threshold crossed. Once the max size is reached, old archive files will be purged to make space for new ones.), (Recommended Action: None. However if purging of archive files (once max size is reached) is not desired then, create a backup of the archive files now OR increase the max size.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-MPLS_LABEL_LSD_RW_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Service-layer could not program the label in Label Switching Database.), (Recommended Action: Programming for label failed in Label Switching Database. This can occur if the ILM or NHLFE attributes are not proper - such as attempting to add a label before label block allocation. Look for Service Layer traces for more information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-DC_IDPROM_READ ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC driver was not able to retrieve a valid IDPROM image from the daughtercard of the indicated location.), (Recommended Action: Use hw-module location location reload command to reset the card to see if it can clear any I2C issue that was preventing the reading of the IDPROM.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the mutex synchronization mechanism? ### Response: A mutex (mutual exclusion) lock is used to protect shared data. Before accessing the data, a thread must acquire the mutex. This blocks other threads from accessing the data simultaneously. When the thread is done, it releases the mutex, allowing other threads to acquire it. This prevents race conditions and data corruption. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_INVMGR-6-IF_OIROUT ### Response: (Severity: 6), (Category: PLATFORM), (Description: SFP or XFP or CFP or QSFP entity is removed from the line card.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-SWITCH_FIRMWARE_BOOT_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process either timed out while waiting for the switch's Microinit firmware initialization to complete, or the switch reported Microinit boot state as 'failed'. In order to recover, ESD will reset the switch, then exit so that it can be restarted by the process manager and attempt to configure the switch again.), (Recommended Action: If this problem does not recur, no intervention is required to recover. To determine why this problem occurred, or if the problem occurs multiple times, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet', and 'show controllers switch trace' commands. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different ways to clear BGP sessions? ### Response: BGP sessions can be cleared in the following ways\n- Hard reset - Tears down the TCP session and re-establishes it. Disruptive.\n- Soft reconfiguration inbound - Performs a route refresh to get routes from the neighbor again. Requires storing a copy of received routes.\n- Route refresh - Performs a route refresh to get routes from the neighbor again. Requires route refresh capability.\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU_DRVR-3-RETIMER_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: The device failed, most likely reason is firmware download failed), (Recommended Action: Collect all the event logs and the output of the following commands executed from the CLI of the active RP if the asic is continuously reset and recovery does not take place after device reset: 1. 'show processes npu_drvr location ' 2. 'show controllers npu retimer id all slot all' 3. Collect all traces: 'show controller npu trace all location ' 4. dmesg and /var/log/messages from host OS If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FDI-3-ERR_TLV_TYPE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB/Driver received a FDI message containing structure(s) with invalid TLV type. This means that the TLV encoding code is missing some structure entry. After an occurence of such error, it is likely that FSDB and Driver have gone out of sync.), (Recommended Action: Capture information as specified in the required_info section. Restart FSDB/appropriate driver (from whichever process context this error message was logged) to clear any 'out of sync' issues.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IGPTE_LIB-3-ERR_LTRACE_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: A process failed to initialize internal tracing buffers in the IGP/TE API DLL), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMGR-3-VM_INSTALL_FAIL ### Response: (Severity: 3), (Category: OS), (Description: VM install/upgrade/unistall failure description.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-4-MEMORY_STATE_CHANGE ### Response: (Severity: 4), (Category: HA), (Description: The free memory state of this node has changed to the indicated state.), (Recommended Action: If the free memory state is Severe or Critical, investigate memory usage on this node. It may be necessary to unconfigure some applications or move them to a different node. In the case of memory leaks, technical support may need to be contacted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV6-5-RECURSIVE_LOOP ### Response: (Severity: 5), (Category: L2), (Description: Recursive loop was detected. The route update will be dropped), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPM-3-ERROR_MALLOC ### Response: (Severity: 3), (Category: SECURITY), (Description: The system could not allocate memory for the specified function.), (Recommended Action: 'This indicates low memory condition, please try after freeing up some resources.' 'If this message recurs, Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-4-ADDRSVR_INIT ### Response: (Severity: 4), (Category: IP), (Description: Failed to initialize as local IP Address Server), (Recommended Action: Restarting ipv6_ma may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHUNK-7-BADELESIZE ### Response: (Severity: 7), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_9_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-REPLY_FAIL ### Response: (Severity: 3), (Category: SYSDB), (Description: SysDB encountered an error while sending reply to its client.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-4-IP_ADDRESS_NOT_FOUND ### Response: (Severity: 4), (Category: SECURITY), (Description: There is no IP address configured for the specified interface.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-6-SHMRESET_NON_RELOAD_SMU ### Response: (Severity: 6), (Category: ROUTING), (Description: SMU installed has been designed to cause SHM reset without having to reload the router. Till fib_mgr initializes there will be impact on traffic.), (Recommended Action: None, since this is expected behavior of the SMU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_SW-3-ERR_NETIO_MUTEX_LOCK ### Response: (Severity: 3), (Category: IP), (Description: The IPv6 NetIO component was unable to lock packet mutex while doing a control action. The control action failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-CORRUPT_CHECKPOINT ### Response: (Severity: 3), (Category: INSTALL), (Description: Checkpoint data for the Install process is corrupt. The data will be deleted and the install process restarted. Any information about any install operation that is in progress has been lost.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-7-GET_BCAST_ADDR_INFO ### Response: (Severity: 7), (Category: OS), (Description: Unable to get the broadcast address %x- error code %s- Error description), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-3-ERR_SYSDB ### Response: (Severity: 3), (Category: IP), (Description: The Telnet client has encountered an error using the SysDB Library.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_HFR-7-ERR_EDM_REGISTER ### Response: (Severity: 7), (Category: ROUTING), (Description: The MFWD-HFR library encountered internal error during EDM init setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_RX_ALIGN_LOSS_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Rx alignment loss on XAUI to NPU-1 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-UPD_MSG_ALLOC_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: An error was encountered when allocating update message buffer. Update generation for the affected update-group will be retried after some time and will recover when the memory condition improves.), (Recommended Action: Please check the memory state on the router. Please also consider tuning the update limit parameters using 'update limit ...' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ASIC-1-SW_ERR ### Response: (Severity: 1), (Category: L2), (Description: The operation is failed due to an internal software error. %d - instance. %s - description of the operation. %s - description of the error.), (Recommended Action: Check if the linecard reported any other errors. Copy the error message exactly as it appears on the console or in the system log. Issue the show asic-errors plim asic all location <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show asic-errors plim asic all location <> output, call your Cisco technical support representative and provide the representative with the gathered information. May need to restart process. 'process restart pla_cge_maint loc <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-ARRAYTOOBIG ### Response: (Severity: 4), (Category: MGBL), (Description: The number of elements entered by user in an array are more than this application is designed to handle.), (Recommended Action: * RECUR *) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-4-MEM_CRITICAL ### Response: (Severity: 4), (Category: OS), (Description: If GSP process memory is in critical state it indicates that one of the internal queues is building up or there is a memory leak.), (Recommended Action: Collect running core dump of gsp) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDLD-3-DAEMON_INIT_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The UDLD Daemon failed to initialize correctly, and will now exit. It should be restarted by SysMgr.), (Recommended Action: The UDLD Daemon will restart automatically in an attempt to resolve the error condition. The user may also be able to identify potential system-wide issues through the error string accompanying the message and attempt to resolve these issues to assist with UDLD Daemon restarts. If the error message indicates out of memory issues Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATMSNMP-3-SYSDB ### Response: (Severity: 3), (Category: SNMP), (Description: This message indicates the ATM SNMP library fails to perform a SYSDB operation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_EVC_NOTIFY ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: During initialization, PPPoE MA failed to register for essential notifications regarding the state of the connection for the specified service. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-ITAL_REG_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured when registering to ITAL.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging processes msdp | inc ital command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging processes msdp | inc ital output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace events command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace events output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_400G_POD-3-HIGH_2_5VCC ### Response: (Severity: 3), (Category: FABRIC), (Description: The POD detects a high in 2.5Vcc voltage. The POD might not be functioning properly, and can cause cell drops or corruption in the rx or tx link associated with the POD.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MARVEL-3-NOMEM ### Response: (Severity: 3), (Category: L2), (Description: This error is reported when malloc()/calloc() type system call fails.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-3-EVENT_CONN_NOTIFY ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to set notify handler for connection opens, closes and errors.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-OUT_MEM_ERROR_LNK0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected an output memory error on link 0), (Recommended Action: This alarm is transient and should auto-clear when error condition is resolved. If the alarm doesn't clear, then please reload the card using command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-IFINDEX_GET ### Response: (Severity: 4), (Category: ROUTING), (Description: An error occurred when trying to get a numeric interface index value for the specified interface. Ietf nsf restart might fail.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-7-OPERATION_DEBUG ### Response: (Severity: 7), (Category: PLATFORM), (Description: This is a programmed diagnostic debug.), (Recommended Action: No action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ_MGR-7-ERR_BAG_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: EDM Bags are used to share information between components using sysdb. This Error indicates that bag registration failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TSEC-6-DRIVER_INFO_2REG ### Response: (Severity: 6), (Category: PLATFORM), (Description: The particular operation mentioned in the message gave an informative message with two register values. This is not a failure.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPDRIVER-3-SBM_IMEM_MULTIPLE_BIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that during initialization the SBM SPICO IMEM for the indicated ring and NP had uncorrectable bit errors in instruction memory.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does SysDB collaborate with Configuration Manager in IOS XR? ### Response: SysDB collaborates with Configuration Manager in IOS XR by storing the configuration data and notifying relevant processes when configuration changes occur. Processes can register with SysDB to be notified of specific configuration changes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT-3-ERROR_LOG ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, Tomahawk specific init error), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>), 'show install active', 'show logging console', 'show platform' and 'show version'. Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_CLIENT-7-JID_GET_ERROR ### Response: (Severity: 7), (Category: OS), (Description: process's JobID can not be obtained), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFEA_IPV6_EA-3-ERROR1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: AFEA IP-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_15_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-3-SYSMGR_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: iq manager encountered an error and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-SWITCH_ALL_PORTS_DOWN ### Response: (Severity: 3), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process detected that all ports on the indicated switch moved to down state. When this occurs, the switch is in an indeterminate state, and its packet processing functionality is disabled. In order to recover, the ESD process resets the switch, then exits so that it is restarted by the process manager.), (Recommended Action: If this problem does not recur, no intervention is required to recover. To determine why this problem occurred, or if the problem occurs multiple times, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet' and 'show tech-support ctrace' commands. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_15_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_15 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FLOWTRAP-3-INIT ### Response: (Severity: 3), (Category: OS), (Description: Initialization of FLOWTRAP process which is responsible for EPFT feature is failed to complete.), (Recommended Action: sysmgr will try to restart the FLOWTRAP process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: uea-1-RESTART_NOT_SUPPORTED ### Response: (Severity: 1), (Category: PLATFORM), (Description: This is an error message in the DPA module to indicate that a process that doesn't support restart has been restarted (crash, CLI or SMU installation) Process will trigger node reload to recover after collecting required information in the linecard's disk), (Recommended Action: Please collect the core file and DPA traces from linecard's disk Ignore this if process was operationally restarted like process restart command or process restart SMU installation those operations are not supported yet and nothing to debug at this point) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBCORE-3-SNMP_TRAP ### Response: (Severity: 3), (Category: SNMP), (Description: An attempt to generate/send SNMP trap notification failed. It will also print reason of failure as well.), (Recommended Action: Collect following outputs: - show logging - show sonetmib trace location <> - debug snmp mib ifmib - debug snmp mib sonetmib - debug snmp mib ciscosonetmib) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-6-IMPLICIT_DOWNLOAD_FAIL ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: An error was repeatedly encountered while attempting to replicate the dataplane of an interface to a node to which it implicitly required replication (e.g. due to wildcard replication being used, and a new node coming up later). This may cause forwarding on this interface (via this node) to be broken.), (Recommended Action: The download will continue to be retried, so if the issue is transient and just taking a long time to clear then it will clear eventually and this message will stop appearing. If this message continues to be seen for a long time Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-6-ENFORCE_INC ### Response: (Severity: 6), (Category: LICENSE), (Description: The licensed feature is enabled with appropriate licenses.), (Recommended Action: 'INFO') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HOSTNAME_SYNC-3-SYSDB_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Could not bind to or register to sysdb), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-3-PCIE_TX_FIFO_MBE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_BRIDGING-7-PFI_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the PFI-IFH module in the platform L2FIB BRIDGING component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-UNKNOWNTOKEN ### Response: (Severity: 3), (Category: MGBL), (Description: 'The parser token type is undefined in the specified tree'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Bulk Content Downloader (BCDL) service? ### Response: BCDL is a service used to efficiently download large data sets, such as forwarding tables, from routing processes to line cards and fabric cards. It leverages GSP to provide reliable multicast transport. BCDL handles downloading data to multiple consumers, tracks download state, and performs incremental updates. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDP-7-SOCKET_INIT ### Response: (Severity: 7), (Category: IP), (Description: An software error occured when the UDP process do socket related initialization.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_EDM-3-DATALIST_ADD_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The attempt to add an item to an external data manager datalist has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBSOC-4-SVC_WARNING ### Response: (Severity: 4), (Category: OS), (Description: A service API warning is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-LKGP_ADD ### Response: (Severity: 3), (Category: ROUTING), (Description: The IS-IS process failed to configure link-group on the interface with specified error reason.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTAGENT-3-HUSHD_CAPI_CALL_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The capi service call to hushd to request for disk detach has failed. This means that the secondary disk partition for XR will not be passed through to XR and as a result the SDR prepare might fail.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-3-DB_SANITISATION_INTERRUPTION ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Ifmgr has detected an interruption in IM DB sanitisation, which may have happened due to previous ifmgr restart (can be user initiated or crash). ifmgr will try to recover this entry via resync now.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHANCON-3-MSG_TOO_LARGE ### Response: (Severity: 3), (Category: OS), (Description: Connector poll returns error.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-CHASSIS_REIMAGE_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Chassis wide reimage operation has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-4-NOMEMORYW ### Response: (Severity: 4), (Category: ROUTING), (Description: The requested operation could not be accomplished because of a low memory condition but the problem has ben handled locally.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information as given in the required info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-STATS_EXCEED_RANGE ### Response: (Severity: 7), (Category: SYSDB), (Description: Statistics update reveals the range has exceeded.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-2-CAL_CHIP_NMI_DISABLED ### Response: (Severity: 2), (Category: MGBL), (Description: Unable to get NMI info from platform..), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_10_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-2-MONITOR_NOTIFICATION ### Response: (Severity: 2), (Category: L2), (Description: This fault indicates a deadlock or inconsistent s/w state that npu_driver process has detected.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOL_DEMB ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-EVM_INIT_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Failed to initialize the event manager due to the reason shown), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR auto-tunnel backup exclude-srlg feature? ### Response: The MPLS TE FRR auto-tunnel backup exclude-srlg feature allows auto-tunnel backup tunnels to avoid using links that are part of the same SRLG (Shared Risk Link Group) as the protected interface. SRLGs define groups of links that share a common failure risk. By excluding SRLG links, backup tunnels can provide better protection against multiple correlated failures. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-3-DEBUG_INIT ### Response: (Severity: 3), (Category: IP), (Description: An software error occured when the TCP process try to do debug related initialization.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WAN_INARP-3-UNKNOWN_EVENT ### Response: (Severity: 3), (Category: L2), (Description: The system must be sending messages we didn't register for. They will be ignored.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_4_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RLOGIND-3-ERR_SPAWN ### Response: (Severity: 3), (Category: IP), (Description: Internal error in spawning login child process.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-TFTP_TIMER_INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: The CE-TFTP server process exited since initialization of the event manager to handle the timer expiry events failed.The process will respawn itself.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-CLOCK_GENERATOR_FAULT ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC FPGA detected fault on one of the Clock Generator device on the card. This is an indication Clock Generator reporting a failure condition: Loss of Signal, Loss of Lock or Holdover condition. This can result in card going to POWERED_OFF state if the fault is persistent.), (Recommended Action: Try reloading the card using 'hw-module location <> reload'. If multiple card reload operation cannot fix the problem, check if physical OIR can address the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCMGR_DLL-6-PERFMON_NOTSUPP ### Response: (Severity: 6), (Category: PLATFORM), (Description: Processor Manager Linecard CPU driver doesn't support performance monitoring according to the specifications of the hardware.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-LOST_EVENT ### Response: (Severity: 4), (Category: L2), (Description: The specified process failed to receive an event that was sent to it.), (Recommended Action: If any problems are seen, they may nbe rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-THREAD_CREATE_FAIL ### Response: (Severity: 7), (Category: OS), (Description: Dumper creates threads for various activities, here pthread_create failed to create a thread mentioned as start routine.This will have an impact on the behaviour of dumper. It will not impact traffic.), (Recommended Action: Please collect the following data and contact support 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. follow process ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_9_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_9 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_ICPE_EA-3-INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An initialization error has occurred while trying to bring up the LC hardware in the platform ICPE_EA component. The platform software should recover automatically.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBDLLMGR-7-OVERFLOW ### Response: (Severity: 7), (Category: OS), (Description: An overflow encountered for the process. This is not an error.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_12IN1-6-INVALID_CLOCKRATE_CLEAR ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-7-RECORD_TOO_LONG ### Response: (Severity: 7), (Category: OS), (Description: A feature record is too long.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDS_DB-3-PROC_AVAILABLE ### Response: (Severity: 3), (Category: OS), (Description: System manager process is not available.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLDP-5-BRANCH_ADD ### Response: (Severity: 5), (Category: ROUTING), (Description: A mLDP branch has been added.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND-3-ERR_AIB_CONN ### Response: (Severity: 3), (Category: IP), (Description: The IPv6 Neighbor Discovery (ND) process (ipv6_nd) failed in an attempt to communicate with the Adjacency Information Base (AIB) process (aib). This is normally a transient problem that will correct itself. If the problem persists, forwarding of IPv6 packets may be impacted. Check that the AIB process is running and that it isn't being blocked by some other process. Also examine any other error messages arising alongside this one.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_INVALID_RESP ### Response: (Severity: 3), (Category: SECURITY), (Description: SSH encountered some invalid error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VCM-2-IM_PVC_FAILED ### Response: (Severity: 2), (Category: L2), (Description: PVC creation got failed . We may get this error if the connection with PVC does not exist or not ready.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. It is a PVC creation failure, try deleting and reapplying the pvc once again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-MIBCFGFAIL ### Response: (Severity: 4), (Category: SNMP), (Description: While snmp startup sub-agents need to come up within 30 sec, if it happens in both active & standby nodes no issues will come, but if subagents not came up on active node and came up in standby node, mib related config verification will not validate by snmpd & active mibd so there was a chance to miss the mibd related config.), (Recommended Action: if mib related config not get effect re-apply the mibd's config. if Still notice error contact technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-DEBUG_DLL_HOOK_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-4-PEER_REACHABILITY_CLEAR ### Response: (Severity: 4), (Category: L2), (Description: ICCP-SM has detected that the peer node has been restored and has attempted to recover the ports in the redundancy group.), (Recommended Action: This message may not require any action. However the show l2vpn iccp-sm group number command may be used to verify the state of the ICCP-SM bundles. Reference the L2VPN ICCP-SM section of the IOS XR documentation for details on core isolation failures and related configuration commands.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-CPU_STARVED ### Response: (Severity: 6), (Category: L2), (Description: The Ethernet Link OAM Daemon has been blocked or starved of CPU time. As a result, it will not have been able to send out periodic heartbeats regularly, potentially causing OAM sessions to drop. The problem is likely due to unusually high load on the system.), (Recommended Action: Identify any potential high CPU users, and reduce their impact. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_INFRA-4-COMMS_INIT_FAILURE ### Response: (Severity: 4), (Category: INSTALL), (Description: A failure occurred attempting to (re)initialize a necessary communication channel required by the ISSU Director. ISSU Director will restart itself and attempt to resync.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_CHKPT ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA encountered an error using the Checkpoint Service. The error message describes what operation has failed and why it failed. The most likely reason for this a low memory condition but the error could also be caused by a programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-7-FUNCTION_PATH ### Response: (Severity: 7), (Category: OS), (Description: A function call returned an unexpcted error), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_5_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-MISS_EOP_0_XAUI_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Missing EOP-0 from XAUI on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-2-ERR_EXT_MEM_MBE ### Response: (Severity: 2), (Category: FABRIC), (Description: Fabricq external memory MBE (multi-bit error).), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-INVALID_ARG ### Response: (Severity: 7), (Category: INSTALL), (Description: An internal error has occurred in an application that has caused it to pass invalid data to the Package infrastructure. The current request or operation may not be carried out.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_1_ERR2_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 1 ran into error-2 on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-ERR_ALM_API ### Response: (Severity: 3), (Category: ROUTING), (Description: An ALM/LSD API returned an error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APPMGR-3-APP_CLEANUP_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The IOS-XR appmgr has errored or failed while attempting to cleanup an application running on the previous active RP prior to switchover.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-3-LOOPBACK_CONFIG ### Response: (Severity: 3), (Category: PLATFORM), (Description: Loopback is not supported in OTN mode.), (Recommended Action: Use controller dwdm for loopback config. If loopback is not configured in suggested mode Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - sh platform - sh processes vic location <> - show tech-support ethernet interface) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VS_CLIENT-3-CACHE_LOOKUP_NOT_PRESENT ### Response: (Severity: 3), (Category: INSTALL), (Description: Test code only - will never be seen by customers.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_4_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-CIH_LIB_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver cannot initialize the Common Interrupt library infrastructure for interrupt and error handling and logging. The node might not be able to handle interrupts.), (Recommended Action: Collect all the event logs and 'sh controller fabric trace driver all location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-DB_INITFAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: CGN_MA failed to initialize a particular database. The process will be restarted under this scenario.), (Recommended Action: Try restarting the CGN process showing this error. Please contact support if the issue does not get resolved after process restart.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LMRIB_API-3-GENINITFAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Error occurred at client initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show lmrib client trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show lmrib client trace output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_ATOM-7-LTRACE_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the ltrace module in the platform L2FIB ATOM component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBCSVI_BILLING-3-CONFERR ### Response: (Severity: 3), (Category: SERVICES), (Description: Couldn't not establish the SBC instance name from SysDB. SBC instance name is required for the billing cach paths SBC billing application will not be able to save billing records.), (Recommended Action: Delete the SBC instance and create it again to mount the SBC billing drives.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-TUPLEUNPACK ### Response: (Severity: 3), (Category: MGBL), (Description: 'sysdb tuple unmask operation failed. The sysdb string is displyed in the error message.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_IN_MEM_UCORR_ECC_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast input memory uncorrectable ECC error on link 2), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-LINK_ERROR ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. For Link in error state : This link is in error state due to errors on the link.), (Recommended Action: Reset the link. In most cases after reset of the link it should come UP fine. Collect all the event logs and the output of the following commands executed from the CLI of the active RP: 1. show controller sfe link-info rx 0 127 topo instance all loc 2. Collect all traces:'show controller sfe trace all location ' 3. Collect DSC and eyescan data for this link and also for the far end link If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-IP_RIB_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured while processing updates to RIB. This error is unexpected and fatal.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-4-GISO_ZTP_SYNC_FAILED ### Response: (Severity: 4), (Category: INFRA), (Description: An unexpected error occurred while trying to sync the gISO ztp.ini file from the active RP during diskboot. If ZTP configuration from a gISO is expected to be in use, this has not been synced to this node.), (Recommended Action: Use ZTP commands to check that ZTP configuration is as expected on this node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_LOCAL-3-BULK_SERVICE ### Response: (Severity: 3), (Category: L2), (Description: vt_bulk_set_service failed while executing the function in question. The message contains information about the location and cause of the failure .), (Recommended Action: This error indicates a problem in the code and cannot be easily recovered from. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_OPTICS_TEMP_OUT_OF_RANGE ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-2-SESSION_COUNT ### Response: (Severity: 2), (Category: SECURITY), (Description: Attempted to decrement session count which is already zero after a SSH session has been terminated.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY_CONNECT-3-INTERNAL ### Response: (Severity: 3), (Category: MGBL), (Description: The TTY Connection library encountered an unexpected error during normal operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SSM_PRC ### Response: (Severity: 6), (Category: L2), (Description: The quality level of the source has been changed to or from PRC.), (Recommended Action: None, this is an informational condition that does not require troubleshooting.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RASF-7-DBGINIT ### Response: (Severity: 7), (Category: ROUTING), (Description: The debug event initialization failed. The rasf will still run correctly, but debug commands may be unavailable.), (Recommended Action: There is no effect on functionality Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPIO_PD-3-FGID_JOIN ### Response: (Severity: 3), (Category: PLATFORM), (Description: FGID join failed. Packet path initialization to RP errored.), (Recommended Action: Restart the spio_ma process. 'process restart spio_ma location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPMgr-3-ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Error message), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-EVM_CODE ### Response: (Severity: 3), (Category: ROUTING), (Description: A call to an external event manager function failed. The impact of this error is insignificant, unless the error condition persists for a duration close to the minimal DeadInterval used over all OSPF interfaces.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMC-7-MISSING_NODE_NFN ### Response: (Severity: 7), (Category: SYSDB), (Description: No node down notification was received from the underlying infrastructure for a recent node reload.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_AB_INTR_FIFO_URUN_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_AB_INTR_FIFO_URUN interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-ERR_MEM_NHPATH ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occured when trying to clear redist information for a client.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-3-MILESTONE_COMM_FAILED ### Response: (Severity: 3), (Category: L2), (Description: ISSU Lite returned an error when the process tried to inform it that the a milestone had been started/met. The error messgage will contain more information. This may stop the process from declaring itself ISSU ready and may cause the ISSU to abort.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-NP_PLL_LOCK_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected a clock failure on NP), (Recommended Action: Please check power slice shut/no shut recovers the issue if the issue is persistant ,reload the LC hw-module location reload 0/x force if the issue is seen even after LC reload,RMA LC If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-7-REGISTRATION ### Response: (Severity: 7), (Category: HA), (Description: An error was encountered during table registration. The message should indicate the error condition. This is most likely due to a coding error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-6-TOP_SHMEM_USER_INFO ### Response: (Severity: 6), (Category: HA), (Description: This process is one of the top sharedmemory users in the system. If the system reaches critical memory exhaustion, this process is subject to restart or termination. If the process is listed as 'Killed', then the system is in the process of recovering the resources used by the process.), (Recommended Action: Collect system log information. Contact technical support if the problem is not a misconfiguration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-6-INFO_FGID_RECOVERY ### Response: (Severity: 6), (Category: FABRIC), (Description: FGID high watermark level crossed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_INVALID_MSG ### Response: (Severity: 3), (Category: SECURITY), (Description: SSH encountered invalid LWM message received .), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN-3-DEBUG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to initialize or shutdown the debug module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-4-FWC_FMI_IFH_MISMATCH ### Response: (Severity: 4), (Category: SECURITY), (Description: The Firewall Controller has been informed of the creation of a Firewall Management Interface, but found that the interface handle for the interface differs from the handle in its database. This error message indicates an inconsistency in the firewall database, which may result in unexpected behaviour.), (Recommended Action: If this message is seen and the state of firewalls on the router does not match the expected state as a result of configuration, restart the Firewall Controller process using the 'process restart' mechanism.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-6-AGENT_REG_SUCCESS ### Response: (Severity: 6), (Category: LICENSE), (Description: Smart Licensing registration successful.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TTI_MISMATCH_DEMC ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-DIAG ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Network Processor experienced a self diagnostic error in operation. The error is automatically recovered via self healing NP fast reset. Minor loss of traffic is expected during recovery.), (Recommended Action: If infrequent this can be ignored. If the problem persists logs are kept automatically for Cisco to analyze. Call your next level of support if this is seen twice in a week.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LOW_VOLTAGE_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ voltage less than or equal to the low voltage warning threshold. The QSFP+ is the pluggable optics on the line cards. The voltage threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check the 'show environment voltages'. If the system voltage is normal then replace the optics with working one (if any). If the system voltage is not normal, then make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_AGG-3-NM_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB aggregator failed NM initialization with above reson.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB_API-3-LWM_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Error occurred in mrib client lib.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_GENERIC ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-LICENSE_WILL_EXPIRE ### Response: (Severity: 4), (Category: LICENSE), (Description: The specified feature's evaluation license will expire in the time indicated. After the license has expired the feature will become unusable. This message appears even if the feature is not currently configured.), (Recommended Action: In order to continue using the feature, contact Cisco to purchase a permanent licenses and install it using the 'license add' command in admin mode. If the license is not needed, the messages can be stopped by removing all licenses for that feature using the 'license remove' command in admin mode.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-BAG ### Response: (Severity: 4), (Category: L2), (Description: ELMI encountered an error using the Bag Client library. The error message describes what operation has failed and why it failed. The most likely reason for this a low memory condition but the error could also be caused by a programming error. The error will affect ELMI's ability to provide operational management data, but won't otherwise affect ELMI's operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ED_SCH_INTR_MC_QTYPE_HANG_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ED_SCH_INTR_MC_QTYPE_HANG interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SYNC-7-SHMEM_ERROR ### Response: (Severity: 7), (Category: OS), (Description: Shared memory operation failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_CHAR_ALIGN_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-1 char alignment error on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_ASR9K_SCH_LIB-3-EVM_CREATE_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message signifies that the communication between that the event-creation manager has failed in context with the Smart-Call-Home feature.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_6_HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TAMSVCS-5-TAM_DBG_PROC ### Response: (Severity: 5), (Category: SECURITY), (Description: Internal TAM debugging related error which limits TAM debuggability.), (Recommended Action: TAM internal debugging related error has occured which limits debuggability of TAM.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOGMIB-3-TARGET_CFG_PROBLEM ### Response: (Severity: 3), (Category: SNMP), (Description: An internal software error occurred.), (Recommended Action: Collect Show tech-support cfgmgr on the location where this error is seen also collect show config sessions detail, show config history reverse, show cfgmgr trace location all and show logging output .) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-ROUTE_RECONCILIATION_COMPLETE ### Response: (Severity: 4), (Category: PLATFORM), (Description: System is booting in warm mode and was resynchronizing routes with the ASIC. Re-conciliation is now complete and configuration can now be done.), (Recommended Action: No recovery is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBAPI-3-NOMEM_ERROR ### Response: (Severity: 3), (Category: SNMP), (Description: The requested operation could not be performed due to a low memory condition.), (Recommended Action: 'Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ERR_SYSDB_GET ### Response: (Severity: 3), (Category: MGBL), (Description: 'An error occurred while accessing sysdb. The error is displayed in the error message.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-5-DIA_PEER_DOWN ### Response: (Severity: 5), (Category: SECURITY), (Description: Error encountered while using the System Database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-3-SHM_ERR ### Response: (Severity: 3), (Category: L2), (Description: Error occurred in operations related to Shared Memory area. Initialization of the server side of shared memory failed. This could have happened due to overuse of memory. This results in - 1) Not programming hardware for proper forwarding. 2) Not creating new bridge.), (Recommended Action: To minimize the scaling of bridges, some processes that provide unnecessary services can be removed from the configs. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-ERR_DETAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, error information), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NQC-3-INIT_FAIL ### Response: (Severity: 3), (Category: OS), (Description: An software error occurred while initializing the NSR FAIL OVER functionality. If this occurred during process startup, then the process may be restarted.), (Recommended Action: The process may attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ROULETTE-3-INVALID_SLOT_BUS ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message related to the Canbus Controller processing the received message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-CONFIG_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_2_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias less than or equal to the low laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KENSHO_GL-3-PCIE_ATTACH_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: pcie attach has failed and process will respawn), (Recommended Action: The Procmgr process will automatically respawn up to a fixed number of times. Verify the process is running: 'show process procmgr location <>' If it is still non-operational, execute 'process restart procmgr location <>'. If the process still fails to spawn, contact support with the required info. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD_CONF_PRX-3-ERR_BAG_DECODE ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-ACTOR_CHURN ### Response: (Severity: 5), (Category: L2), (Description: Actor churn has either been detected (due to the failure of a link to synchronize soon enough) or has been cleared. If the link is in Standby state, then actor churn will be detected after the churn timeout; this is expected behavior. Otherwise, this indicates a possible misconfiguration.), (Recommended Action: If actor churn has been declared and the link is not marked as Standby, check that the configuration for the link allows it to aggregate, and fix as appropriate. Check for misconfigurations between the two ends of the link which is reporting churn. The output of the show bundle command may help identify the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-3-EVENT_CONN_CREATE ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to create event connection.), (Recommended Action: The process may recover itself from this error as there is a retry mechanism. If the issue is seen continuously, Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO_COMMON-4-VERIFY_INIT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The process has failed to initialize a module, and will be restarted.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_ENCAP_DB-2-NH_NOTVALID_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: NH has not been inserted in AVL tree. Valid bit not set), (Recommended Action: The following needs to be collected and DE team to be contacted. show encap-id platform egress-db all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_CLOCKTIME ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occurred while retrieving the time of a System Clock. This may be due to resource starvation or an internal software programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install verify filesystem command in IOS XR? ### Response: The 'install verify filesystem' command is used to verify the integrity of the filesystem on the router's storage devices. It checks for any filesystem corruption or inconsistencies and reports any issues found. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-ISSU_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: Fatal error in one of the ISSU apis.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_ICCP_SM-3-CONFIG_ERROR_CLEAR ### Response: (Severity: 3), (Category: L2), (Description: Mis-configuration under l2vpn redundancy has been cleared. The primary set of VLANs now matches the secondary set of VLANs on the other member of the redundancy group.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-4-INTERFACE_EXIST ### Response: (Severity: 4), (Category: IP), (Description: IPv4 MA already has the interface being newly added in its internal store. This potentially indicates that IPv4 MA missed the delete from SysDB and Interface Manager for this interface & hence is out of sync.), (Recommended Action: IPv4 MA restarts in an attempt to recover from this situation, config should get applied on this new interface successfully. No further action should be necessary. If errors are observed, trying to unconfigure and reconfigure the interface in problem would help. If that does not and IPv4 MA related errors are still observed please gather the necessary information as mentioned in required info Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV6-3-WARNING_STR ### Response: (Severity: 3), (Category: L2), (Description: A runtime error occurred in ASR9K IPv6 FIB module. The reason for the failure is also displayed. Please call Cisco Support with the error information.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace [common|ipv6] all loc <>). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-4-TRACE_INIT_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: CLNS failed to init with the ltrace subsystem. This affects the debuggability of the component. CLNS will attempt to restart to recover from the situtation.), (Recommended Action: Please contact cisco-support in case the message re-occur. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ORA-4-DLL_REG_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: The given cerrno dll could not be marked for use. This does not change the functionality of the system but does obscure the meaning of error codes presented by this part of the system.), (Recommended Action: Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SEG_DATA_FIFO_OFLOW_0_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress seg data fifo overflow on xaui-0 bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_0_PKT_MINLEN_ERR_0 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet minimum length error on NPU-0 interface on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: hytop-6-INFO_MSG ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is a Informational message in the QFPCPUBridge driver %s - indicates the informational message. %d - indicates any additiona data.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV6-6-INFO ### Response: (Severity: 6), (Category: L2), (Description: PLATFORM IPv6 FIB, Information), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-OOR_COUNTER_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-3-LASER_ON_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Operation of turning on the Laser for Coherent Optics Failed), (Recommended Action: As a workaround Optics controller can be admin shut and no shut to attempt recovery) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-3-BPDU_INCORRECT_DMAC ### Response: (Severity: 3), (Category: L2), (Description: STP received a BPDU with the wrong MAC address, most likely belonging to a different protocol.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-BER_ALARM ### Response: (Severity: 4), (Category: L2), (Description: Warning Alarm is raised due to BIP Error Threshold Violation Interface is brought down, if user has configured it. %s - Interface Name. %s - BER Type. %s - Alarm state.), (Recommended Action: Correct the far end or fiber path for this interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-OOR_GLOBAL_BSR_GRANGE_THRESHOLD_WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-4-ROLE_MISMATCH ### Response: (Severity: 4), (Category: PLATFORM), (Description: The role configuration determines the type of service ISM card is going to run. This message is generally encounterd in the cases of RMA or location change of ISM card. It means that the ISM card is not running the service which it is expected to run.), (Recommended Action: Install the image specified by configured role on ISM card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA_TP-3-ETMM_CCEICT_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Internal error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-IDB_HANDLE_MISMATCH_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp global-interface command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp global-interface output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp interface command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp interface output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace im error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace im error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ITAL_SHM-7-ERR_GENERAL ### Response: (Severity: 7), (Category: OS), (Description: Some error occurred in operations related to Shared Memory area. The text of the message displays the failed operation and the related error code. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-3-UNEXPECTED_ERROR ### Response: (Severity: 3), (Category: HA), (Description: An unexpected error condition encountered.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-INVENTORY_DB_INTEGRITY_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: Duplicate entries found in inventory database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIP-4-NOT_SUPP ### Response: (Severity: 4), (Category: L2), (Description: The specified configuration is not supported by the dataplane.), (Recommended Action: If any problems are seen, they may be rectified by removing the unsupported configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-SWITCH_FDB_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process detected that the indicated switch did not respond to a request to clear or modify the switch's forwarding database (FDB). When this occurs, the switch is in an indeterminate state, and its packet processing functionality is disabled. In order to recover, the ESD process resets the switch, then exits so that it is restarted by the process manager.), (Recommended Action: If this problem does not recur, no intervention is required to recover. To determine why this problem occurred, or if the problem occurs multiple times, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet' and 'show tech-support ctrace' commands. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_1_PKT_MINLEN_ERR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet minimum length error on NPU-1 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_15_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the key steps to prepare for an IOS XR software installation? ### Response: The key preparation steps for an IOS XR software installation are\n1. Identify the desired IOS XR release version based on required features and functionality\n2. Determine the necessary SMUs and optional packages to be installed\n3. Verify the hardware (RP, LC) meets the memory and boot device requirements\n4. Procure the bootable image, optional packages and SMUs from Cisco\n5. Ensure management access to the router (console, Telnet/SSH)\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_AUTO_TUN_BKP_ID_LIMIT_EXCEEDED ### Response: (Severity: 3), (Category: ROUTING), (Description: The creation of the auto-tunnel backup aborted since all IDs in the auto-tunnel backup ID range have already been allocated.), (Recommended Action: Increase the auto-tunnel backup ID range or remove unused auto-tunnel configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ORA-4-MISSING_DOCK_INFO ### Response: (Severity: 4), (Category: ROUTING), (Description: This is most likely an internal logic error that resulted in a given ora docking being released more than once.), (Recommended Action: Copy the error message as it is and contact support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_EA_STATS-3-CHKPT_GET_FAILURE ### Response: (Severity: 3), (Category: SERVICES), (Description: An error occured during periodic statistics collection for the interface specified. This means that the statistics (as reported by eg. 'show interface') will be inaccurate for as long as this error is seen.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-OUT_OF_RANGE_ID ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Out of range IDs used for port ranges in ACL match criteria.), (Recommended Action: Remove the port range match criteria from ACL and re-apply.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-5-SC_INTERR ### Response: (Severity: 5), (Category: SYSDB), (Description: The code has performed an action which should not be possible.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-4-DUMPER_SNAP_NODUMP ### Response: (Severity: 4), (Category: OS), (Description: A non-invasive voluntary coredump was requested by the process, but a problem occured that prevented the coredump from being created.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_ASIC_SCAN_UNSUPPORTED ### Response: (Severity: 3), (Category: FABRIC), (Description: SPB is not designed for supporting SPB-motherboard JTAG operation necessary for asic scan functionality. SPB board with this support will have a 73 level base number of 12773. This value is programmed in the SPB EEPROM at locations 42 to 44.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-AD9554_CLOCK_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: AD9554 clock failure/success.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_MALLOC ### Response: (Severity: 3), (Category: OS), (Description: The requested memory is not available), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-SYS_UPGRADE_INFO ### Response: (Severity: 6), (Category: INSTALL), (Description: This may not be a failure, but the information about the progress of the install operation. This message will be sent by the Admin install manager to update on the progress of the system upgrade operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-MGMT_TOO_MANY_VALUES ### Response: (Severity: 3), (Category: MGBL), (Description: The TTY Management Commands Process has been supplied with more values on the command line than it was expecting.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-4-EXIT_NNS_ERROR ### Response: (Severity: 4), (Category: OS), (Description: The Linux Packet Classifier operates in different Linux Network Namespaces, each corresponding to a separate IOS-XR VRF. This message indicates it encountered an error exiting from one of those network namespaces after its work there was complete, and so is now stuck in the wrong namespace. This may affect operation of the Linux datapath, but the standard IOS-XR datapath will not be affected.), (Recommended Action: If Linux datapath operation is important, then a process restart of the spp process (a traffic impacting operation) is necessary to recover. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-3-NSR_SM_TIMEOUT ### Response: (Severity: 3), (Category: L2), (Description: BFD NSR Sync SM timed out because of state timer expiry.), (Recommended Action: Restart corresponding bfd process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-7-HBAGENT_EXISTS ### Response: (Severity: 7), (Category: PLATFORM), (Description: Mbi-hello process was restarted. However, it detected that the hbagent process is already functioning. Hence mbi-hello is going into passive mode by design.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-7-UNKNOWN_MESSAGE ### Response: (Severity: 7), (Category: IP), (Description: The IPV4_MA process has received an unknown IPC. It will ignore the msg if it is in the form of an asynchronous pulse. If the msg is in the form of a synchronous message, it returns an error to the sender which in turn is expected to take appropriate action. This can happen if IPv4 MA receives an IPC for which it doesn't have a handler registered due to either it unregistering the handler without updating the sender or due to the sender sending an incorrect IPC. It may be safe to ignore this message if there is no visible loss of functionality.), (Recommended Action: Collect the output of show tech-support, show processes, show ipv4 ma trace, show lwm from the location the error message comes from. If this message is seen repeatedly, capture the output of debug event-manager dispatch job <>. This debug captures almost all the IPCs received by ipv4 ma and hence it may slow down the process and take up the related resources. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-6-ERR_EVQ_DESTROY ### Response: (Severity: 6), (Category: L2), (Description: During process termination PPP MA failed to destroy an event queue. The process will terminate regardless so there should be no lasting problems.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-5-RP_MAPPING_CHG ### Response: (Severity: 5), (Category: ROUTING), (Description: PIM RP mapping change notificaiton.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPA_1P_OC192-3-DRV_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: SPA driver driver encountered the annunciated error during the driver initialization. The System Manager process (sysmgr) will automatically respawn the (vpa_1_oc192) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_CPP_MCAST_GTRIE-3-LEAF_LOOKUP_FAILURE ### Response: (Severity: 3), (Category: ROUTING), (Description: Error in platform Gtrie Lib), (Recommended Action: Please collect debug multicast-gtrie <> for analysis on the cause If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE_HAL-3-DOUBLE_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: An access error happenned on Squirt or PEX8114 while checking for errors.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE5_LANE_CRC_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE5_LANE_CRC_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What happens when you delete a physical interface configuration in IOS XR? ### Response: When you delete a physical interface configuration in IOS XR, the system automatically removes all configuration associated with that interface, such as IP addresses, routing protocol configuration, and QoS settings. This simplifies interface removal and ensures consistency. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-TDDR_FIFO1_PAR_ERR ### Response: (Severity: 0), (Category: PLATFORM), (Description: TxDDR 200 to 1875 FIFO 1 parity error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-CHASSIS_OVERTEMP ### Response: (Severity: 2), (Category: PLATFORM), (Description: Chassis ambient temperature is over critical threshold. Ambient temperature is the average of the temperature inlet sensor for all RSP plugged in the chassis.), (Recommended Action: Verify the failure, give CLI: (admin)# show env --> particularly temperature and fan output (admin)# show env trace --> to see cards STT values (exec)# show env led details Verify the fan speeds have increased to help bring down the temperature, ambient temperature should decrease with the increased fan RPMs. Chassis can continue to operate in this condition, however cards will shutdown when their hotspot temperature reaches shutdown threshold (STT).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_HFR_LIB-3-LTRACE_NODE_ID_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ltrace node IDs for logging the info/debugging information is failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-WRONG_PLANE ### Response: (Severity: 7), (Category: OS), (Description: RDS library uses ENS/GSP services to read/write data. While using ens API , it returned failure. ens_bulk_register API failed.), (Recommended Action: This is a debug message.No Action required. If problem persists,Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-3-ERR_DETAILS ### Response: (Severity: 3), (Category: SECURITY), (Description: Client address, error, error description.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DEBUG_CERR-7-REGISTER ### Response: (Severity: 7), (Category: OS), (Description: The debug library was unable to register its debug specific condition codes. Condition messages from the debug library are likely to be degraded.), (Recommended Action: Check to see if sufficient memory resources remain for normal operations. Add memory if necessary. Verify the installation of the debug library. Re-load if required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM_LIB-3-MUTEX_REVIVAL ### Response: (Severity: 3), (Category: OS), (Description: New service can't be registered due to other infrastructure issue.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_LMI-3-RECVFROM ### Response: (Severity: 3), (Category: L2), (Description: The socket call recvfrom returned an error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_CKTNUM_ALLOC_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to allocate a circuit ID to the specified LAN interface.), (Recommended Action: Reduce the number of LAN interfaces over which IS-IS is running.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ-3-ERR_CLIENT_REG ### Response: (Severity: 3), (Category: L2), (Description: An internal error was detected while clients are registering to Egressq process.), (Recommended Action: No action is required. Clients will automatically retry to connect to Egressq. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-LWM_2_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PUNT-0-RX_PLL_NOT_LOCKED ### Response: (Severity: 0), (Category: PLATFORM), (Description: RX PLL inside the FPGA device is not locked.), (Recommended Action: The software is not able to recover from this error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-EVM_TM_ATTACH ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to allocate a timer object.When this issue happens, it will trigger an automatic restart of pifibm_server_lc process..), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR auto-tunnel backup exclude-srlg feature? ### Response: The MPLS TE FRR auto-tunnel backup exclude-srlg feature allows auto-tunnel backup tunnels to avoid using links that are part of the same SRLG (Shared Risk Link Group) as the protected interface. SRLGs define groups of links that share a common failure risk. By excluding SRLG links, backup tunnels can provide better protection against multiple correlated failures. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-7-ERR_DEBUG ### Response: (Severity: 7), (Category: MGBL), (Description: 'Debug event logic failed. The reporting function is listed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSV_APP-3-PIO_MMAP_FAIL ### Response: (Severity: 3), (Category: L2), (Description: An error occured as memory map failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-BAD_FPD_IMAGE ### Response: (Severity: 3), (Category: DRIVER), (Description: The indicated FPD image in CCC bootflash does not appear to have a valid meta-data. This means that a previous FPD upgrade operation did not finish the programming operation of the image.), (Recommended Action: Run again the 'upgrade hw-module location fpd ' command to re-program the image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_EVQ_CREATE ### Response: (Severity: 4), (Category: L2), (Description: This is an unexpected error. The PPP MA process will attempt to recover by restarting. The cause may be a resource starvation problem. The error message should provide more details.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-5-OOR_GREEN ### Response: (Severity: 5), (Category: PLATFORM), (Description: Device has come out of severe resource constraint state), (Recommended Action: Please collect the OFA resource information (show controller npu resources all location all). Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_EVC_CLOSE ### Response: (Severity: 4), (Category: L2), (Description: PPP MA failed to close a connection to an essential service. This is an internal error and it requires a restart of the process for recovery.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSVP-3-INIT_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: RSVP could not initialize one or more modules), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-6-SET_DWDM_CARRIER_CH ### Response: (Severity: 6), (Category: L2), (Description: Optics Controller has provisioned optics to [HW Default | Configured | GMPLS Signaled] DWDM Carrier Channel.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCI_SSTAR-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Fabric driver was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM_LIB-6-INVALID_REQUEST ### Response: (Severity: 6), (Category: OS), (Description: There is miuse of library.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-THIRDPARTY_PKG_IN_LIST_NOT_VALID_FOR_SDR ### Response: (Severity: 3), (Category: INFRA), (Description: Thirdparty pkg in initial-image is not valid for SDR. Invalid input.), (Recommended Action: Skim through the input list again and include relevant thirdparty rpm for SDR.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_QOSEA-3-DATABASE_CORRUPTED ### Response: (Severity: 3), (Category: QOS), (Description: The SSE QoS EA module encountered a database corruption error. The message will provide further details on the error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-3-MALLOC_FAIL1 ### Response: (Severity: 3), (Category: L2), (Description: Memory allocation for shim window failed as the identifier is not valid.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHDLC_MA-6-ERR_IM_MULTIPLE_NTFCNS ### Response: (Severity: 6), (Category: L2), (Description: A batch from Interface Manager contained multiple notifications for a single interface. This should not occur but the situation has been recovered successfully by the cHDLC MA. No problems should be seen as a result.), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATS_INFRA-3-ERR_MUTEX_REVIVE ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in stats infra component. The mutex could not be revived.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-3-SW_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An internal software error has occurred for SIM SW infrastructure.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-LOCAL_CARD_IDPROM_READ_FAIL ### Response: (Severity: 3), (Category: DRIVER), (Description: This is a message to notify the user that RP IDPROM read failed and FAKE generated info is used.), (Recommended Action: This is an indication on HW failure and will need RMA of the board) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-EBS_CPP_DATA_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: EBS to CPP packet data single bit error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-ISSU_NFN_REG_FAIL ### Response: (Severity: 3), (Category: MGBL), (Description: Failed to register for ISSU Install notification registration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: FABRIC), (Description: Failed to allocate memory from Heap. This can happen during periods of intense memory resource usage or due to a memory leak - though these are extremely rare occurances. This message implies some message(s) between FSDB and SFE driver was not processed and so they might be out of sync.), (Recommended Action: Capture information as specified in the required_info section. Restart sfe_drvr to clear any out of sync issues. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-7-OPEN_SOCK_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Open of socket failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-7-HA_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: HA related error occurred in Services PLIM driver. Cause of the error will be mentioned in the message displayed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE path-option verbatim feature? ### Response: The MPLS TE path-option verbatim feature disables the default behavior of automatically assigning IP addresses to unnumbered interfaces in an explicit path. With verbatim, the explicit path is used exactly as configured without modification. This is useful when the automatic IP address assignment conflicts with intended explicit paths. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSI_AGENT-2-RESOURCE_DOWN ### Response: (Severity: 2), (Category: OS), (Description: An important resource required to perform an operation was unavailable.), (Recommended Action: Resource Managers: VRF Database: rsi_master Interface Database: ifmgr Please check if the resource managers are running. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_COM_IFIB-7-DEBUG_REGISTER ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when registering debug. This is not a critical error, and the process can continue functioning noramlly despite this failure. Particular debug will not be effective though.), (Recommended Action: Provide the following log: Collect Console logs and output of -show logging process pifibm_server_rp loc ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-INCOMING_QUEUE_FULL ### Response: (Severity: 4), (Category: SNMP), (Description: SNMP trap correlation incoming queue is full; traps already in the queue is emitted on a FIFO basis to free up room for more incoming traps), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_MAIN-4-CLOCK_ACCURACY_UNSUPPORTED ### Response: (Severity: 4), (Category: PLATFORM), (Description: The system timing has switched to enhanced accuracy mode as a result of applying the 'timing-accuracy enhanced' configuration. This accuracy mode is not supported on the line cards mentioned in the message. The timing behaviour on these line cards shall be undefined if the system continues in this mode.), (Recommended Action: Replace the line cards in the message with the ones that support enhanced timing accuracy, or remove the 'timing-accuracy enhanced' configuration and reload the router for changes to take effect.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_IPV4_EA-3-ERROR1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: SSE IPV4-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_MGR-3-INIT ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of the Service Virtual Interface infrastructure. This resulted in the restart of the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UT2-7-ERR_MSG ### Response: (Severity: 7), (Category: L1), (Description: ut2 driver might run into an error that is not a FATAL.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-6-IMAGE_COPIED ### Response: (Severity: 6), (Category: INFRA), (Description: Copied image to start pre-provision actions), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRMS-3-INT_ERR ### Response: (Severity: 3), (Category: L2), (Description: SRMS internal error. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Restart SRMS process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: c2c_pif-3-ERR_SW ### Response: (Severity: 3), (Category: PLATFORM), (Description: The C2C PIF library encountered an error which it cannot resolve.), (Recommended Action: An error would be reported to the client application which should handle this condition appropriately. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-INIT_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: A init failure occurred in CPP Driver which involves exiting the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-FATAL_2 ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: eint encountered a fatal error and is not able to recover from the error. A reason text will be supplied call support with this text. An integer errno will also be printed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_SWITCH-4-DEADLINE_MONITOR_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: Process failed to register with deadline monitor which indicates that the process will not be monitored by wd-critmon.), (Recommended Action: Process showing up this message needs to be restarted to recover. Command to restart the process, - 'process restart location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS traffic engineering auto-tunnel primary feature? ### Response: The MPLS traffic engineering auto-tunnel primary feature allows point-to-point MPLS TE primary tunnels to be created dynamically between tunnel head-end and tail-end routers. It reduces configuration compared to manually configuring TE tunnels. It is enabled with the mpls traffic-eng auto-tunnel primary command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AMT-3-SYSDB_BSCAN_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SE_P2MP_SRVR-3-LTRACE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Encountered an error in tracing module. This error should not impact the major functionality of the module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-4-FWC_INTF_IFH_MISMATCH ### Response: (Severity: 4), (Category: SECURITY), (Description: The Firewall Controller has been informed of diversion creation for an interface, but found that the interface handle for the diversion differs from the handle in its database. This error message indicates an inconsistency in the firewall database, which may result in unexpected behaviour.), (Recommended Action: If this message is seen and the state of firewalls on the router does not match the expected state as a result of configuration, restart the Firewall Controller process using the 'process restart' mechanism.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-ZERO_TIMER_REPEATEDLY_EXPIRING_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: The deadtimer expiry event repeatedly occured with a deadtime value of zero. This could lead to cpu hogging by radiusd process.), (Recommended Action: Restarting radiusd process should get around the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RTC-7-CAL_CHIP_PRINT_OPTION ### Response: (Severity: 7), (Category: MGBL), (Description: Printing option entered in command line.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VCDMA-3-ERR_SYSDB_EDM_REG ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cpuctrl Sysdb Register EDM error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS LDP IGP sync feature? ### Response: The MPLS LDP IGP sync feature ensures that LDP is fully operational on a link before the link is used for IP forwarding. It prevents blackholing of traffic while LDP convergence is still ongoing. The IGP advertises the link only after LDP is converged. It is enabled per-interface with the mpls ldp sync command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_VKG-7-ERR_GEN ### Response: (Severity: 7), (Category: ROUTING), (Description: MFWD-ASR9K library encountered error during setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSS-7-ERR_RSC_REG_INCONSISTENT_VALUE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric statistics server process encountered a transient error due to the inconsistent value of the received message. This error message will be a true error if many error message is logged and the error is persistent.), (Recommended Action: If the error continues, user will need to restart the process for recovery. 'process restart fstats_server ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-EDM_DATALIST_CREATE_FAILED ### Response: (Severity: 3), (Category: OS), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The creation of the external data manager datalist has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_ATTR_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: A call to the IM attribute library failed. This can be caused by faulty hardware, or it may indicate an interface resource is currently unavailable. Recovery may require a restart of the IS-IS process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_IPHC ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error communicating with IPHC MA. The error message describes what operation has failed and why it failed. The most likely reason for this is a temporary connection problem with the IPHC MA, but the error could also be caused by low memory resource or programming error.), (Recommended Action: In many cases, PPP MA will recover by itself. If it does not then restarting the process may help. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the significance of the 'install update' command in Cisco IOS XR? ### Response: The 'install update' command in Cisco IOS XR is used to apply interim software updates, such as bug fixes and security patches, to the active software packages. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_5_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-NO_POLICY_FOUND ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to derive peer key through either of the following ways: pre-shared keys, RSA keys, or certiifcates. Applies only to initiator mode.), (Recommended Action: 'Contact administrator') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: IP), (Description: The Multicast Port Arbitrator failed to allocate memory.), (Recommended Action: The system is running low on memory, if there is lots of config/routes, try reducing it. Do the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If there isn't too much config, then do the following action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_IFH_UIDB_INDEX ### Response: (Severity: 3), (Category: OS), (Description: Failed to find uidb index for an given interface handle. It is likely to be caused by a programming bug or a programming problem happened in the past.), (Recommended Action: Run the command 'show uidb index' to verify whether the uidb index is created for the interface. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSVP-5-BAD_RSVP_MSG_RCVD_AUTH_SEQ ### Response: (Severity: 5), (Category: ROUTING), (Description: The router received an RSVP message with a bad authentication sequence number. It may be possible in some cases that bursts of RSVP messages become re-ordered between RSVP neighbors. It may also be possible that an attack was attempted.), (Recommended Action: If this occurs on a regular basis, and you can verify that the node sending the burst of messages is trusted, use the window-size option to allow for the burst size such that RSVP will not discard such reordered bursts.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL_COORD-4-BAD_GROUP_MSG ### Response: (Severity: 4), (Category: ROUTING), (Description: The rpl multi-version coordinator received a message with a type it did not recognize. The message was ignored.), (Recommended Action: Observe system for other failures contact support team.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_OC768-3-CRITICAL_ERROR ### Response: (Severity: 3), (Category: L2), (Description: PLIM OC768 driver encountered a critical error as described in the error message. This error causes PLIM OC768 process to exit.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PREF_COMPR_LIB-3-INTERNAL_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An internal error occurred in IPv6 Prefix Compression library involves exiting the process. After the associated process restarts, the error should have been cleared. *DDTS*), (Recommended Action: Collect the configuration, syslog and coredump file. Attach them to the ddts. After the process restarts automatically, the error should have been cleared and no user action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-4-DEBUG_REGISTER_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: CLNS failed to register with the debugging subsystem. If this message has been generated then CLNS debugging may not be available. This may be a system resource problem.), (Recommended Action: In case this message is seen multiple times then please contact cisco-support. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-CREATE_VIRT_INST_ENTRY ### Response: (Severity: 3), (Category: OS), (Description: The request to create a DB entry for the named virtual service failed.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR-3-MA_ALLOC ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates that the pbr_ma process has failed to allocate memory. This may be due to low memory conditions on this particular node, or pbr_ma may be using more memory than it is allowed.), (Recommended Action: Reduce system scale. If the problem persists even with reduced system scale, please contact Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ASIC-3-ERR ### Response: (Severity: 3), (Category: L2), (Description: Plim asic driver errors. Typically these errors indicate failure in system services or bad programming of the hardware.), (Recommended Action: Check whether process 'plaspa_server' is up and running. Check if the linecard reported any other errors and/or traffic loss was observed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM_API-3-LOCKING_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: bfm encountered an error and is not able to recover from the error. A reason text will be supplied call support with this text. An integer errno will also be printed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-2-BREAKOUT_UNSUPPORTED_HW ### Response: (Severity: 2), (Category: L2), (Description: The breakout mode is not supported on the hardware . The behavior of interfaces created is undeterministic.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCI_HAL_SATORI-7-CAST_PKTS ### Response: (Severity: 7), (Category: PLATFORM), (Description: %u- No of packets of unicast or multicast.. %s- Packets of type unicast or multicast.), (Recommended Action: debug info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FEA_DLL-3-TCAM_LIMIT ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This message will typically occur when permissible single region size is exceeded or total number of entries allowed in TCAM for a given application is exceeded.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-3-LOG_ERR ### Response: (Severity: 3), (Category: OS), (Description: An Error message logged.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-CRC_ERR_0_FIA_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: CRC error - 0 from FIA on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-7-DEVICE_INFO ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-INIT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Checkpointing is a mechanism to update the redundant RSP with the current configuration and status of the system to help takeover in case of a failover. The checkpoint mechanism needs to be initialized for Sync-controller to update the standby RSP with current frequency syncronization status.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-3-REPEATED_TIMESTAMP_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: In order to know when to perform updates to the UTC offset, PTP requires knowledge of the current PTP timestamp from the hardware. This error indicates that attempts to obtain this timestamp have failed repeatedly.), (Recommended Action: This error potentially suggests a problem with the hardware. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-6-LOCAL_CMD_ACCT ### Response: (Severity: 6), (Category: SECURITY), (Description: Local command accounting for CLIs), (Recommended Action: Added as part of new feature to account all clis) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-6-TEMP_READ_ERR ### Response: (Severity: 6), (Category: PLATFORM), (Description: Informational msg indicating invalid temperature read), (Recommended Action: Software will take corrective action on its own. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-ARM_UPDATE_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp global-interface command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp global-interface output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace iparm error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace iparm error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp interface command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp interface output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace im error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace im error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP next-hop-self command? ### Response: The next-hop-self command causes BGP to advertise itself as the next hop for advertised routes. It is commonly used on iBGP peerings to ensure that the iBGP peer uses the local router as the next hop instead of an eBGP router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_HT1_CRC ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an HTDP CRC error on the HT1 interface.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRP_MAD-3-INVALID_DMAC ### Response: (Severity: 3), (Category: L2), (Description: The destination MAC address of the incoming MRPDU does not match the MAC address expected for this interface. The specific MRPDU will be dropped and the protocol will continue to operate.), (Recommended Action: Use wireshark or another similar tool to verify the destination MAC address of the packet on the wire. Check the received MAC address against other MAC addresses on the device since there may be a possible packet path issue. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM_PD-3-DLL_CERRNO ### Response: (Severity: 3), (Category: L2), (Description: A failure occurred during the registration of the DLL for decoding error codes from the component. This may render certain codes unprintable, but otherwise has no negative impact.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-4-UNSUPPORTED_OOM_STATE ### Response: (Severity: 4), (Category: ROUTING), (Description: A memory state transition notification was received from wdsysmon with an invalid state.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR-7-ERR_EVM_CREATE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while attempting to create an event manager. This failures affects the ability of the process to service various messages / pulses from other threads / processes. This facility is deemed crucial and the process automatically restarts on this failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_EVENTFIND ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MULTILINK_UV-3-ERR_MISCONFIG ### Response: (Severity: 3), (Category: L2), (Description: The Multilink Uberverifier has detected a misconfiguration. It was not detected in the verification phase, so the Uberverifier cannot correct this.), (Recommended Action: The misconfiguration can be corrected by deleting all configuration from the specified interface and its subinterfaces, and then reapplying the configuration. If the problem persists, do the following: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_SHOW_PROTO_REG ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to register for notification of changes on the displayed SysDB path. The error will not affect IS-IS operation but does indicate unexpected system behavior.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp bestpath as-path ignore' command in IOS XR BGP configuration? ### Response: The 'bgp bestpath as-path ignore' command is used to ignore the AS path length when selecting the best path. By default, BGP prefers the path with the shortest AS path length. This command disables that behavior, allowing the selection of a path with a longer AS path if it is better in other attributes such as origin or MED. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-4-PREFPATH_MULTIHOME_UNSUPPORTED ### Response: (Severity: 4), (Category: L2), (Description: EVPN-VPWS with static preferred path configuration is only supported for single-home setups. Received an internal label with a nexthop not associated with EVPN-VPWS single-homing.), (Recommended Action: Unconfigure the pseudowire class which applies to services other than single-homed EVPN-VPWS.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE2_CODE_ERR_HIGH_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE2_CODE_ERR_HIGH interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-3-APIV_NEG_INCOMP ### Response: (Severity: 3), (Category: PLATFORM), (Description: API Version negotiation failed due to incompatible version.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-ILMS_DROPPED ### Response: (Severity: 3), (Category: ROUTING), (Description: A synchronous ILM operation request received when server initialized in asynchronous mode or vice versa; or when server is not ready.), (Recommended Action: Controller and/or agent must ensure that ILM operation requests are sent only in the mode specified by the client initialization message and server is ready. If message is still seen after meeting these conditions, contact Cisco for support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-INTERFACE_DB ### Response: (Severity: 3), (Category: ROUTING), (Description: The rib unexpectedly failed to update the interface -> IP address database.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTORP_CRP-3-TIMER_FAILURE ### Response: (Severity: 3), (Category: ROUTING), (Description: Timer Error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show auto-rp candidate-rp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show auto-rp candidate-rp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging process autorp_candidate-rp error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging process autorp_candidate-rp error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-ERR_INVALID_GROUP ### Response: (Severity: 3), (Category: SECURITY), (Description: AAA failed to recognize the specified server group name. It may be undefined.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-7-DEBUG_MISSED_HEARTBEAT ### Response: (Severity: 7), (Category: PLATFORM), (Description: Heartbeats over control-ethernet from the node in question are being missed. Continous meesages usually indicate a CE transport issue. Please check control ethernet connections to and from the node in question), (Recommended Action: If continous messages seen, do the following: Check dsc process state from node in question Check the control ethernet connectivity to the node. (Check if the cables are okay and also if the switch is operating normally). If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFP-2-LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected an SFP Tx power less than or equal to the low Tx power alarm threshold. The SFP is the pluggable optics on the line cards. The Tx power threshold values are read from the SFP.), (Recommended Action: Verify that the device is properly inserted. Replace the SFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-3-TREE_LOCK_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Failure occured while locking a mutex.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_PW-3-UPDOWN ### Response: (Severity: 3), (Category: L2), (Description: L2VPN Pseudowire state is changed to UP or DOWN), (Recommended Action: If the state change was unexpected, verify the configuration settings for the cross-connect.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-7-ERR_CHKPT_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: The FIA driver failed to register the checkpoint table. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-3-GET_SHIM_INFO_FAIL ### Response: (Severity: 3), (Category: L2), (Description: Could not get shim info for given interface handle), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC4 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL-3-MSG_RINFO ### Response: (Severity: 3), (Category: OS), (Description: A call to a group services rinfo function failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-5-ANCHORCOUNT ### Response: (Severity: 5), (Category: ROUTING), (Description: Error in the flow control algorithm in EIGRP. EIGRP may recover itself temporarily by doing the necessary error handling.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-5-CLOCK_NOTIFICATION_SOURCE_STATE ### Response: (Severity: 5), (Category: PLATFORM), (Description: When a BITS source port goes up or down this notification will come.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-5-SC_NOFILE ### Response: (Severity: 5), (Category: SYSDB), (Description: The instruction file specified when Sysdbcon was started cannot be found. The most probable reason is that an incorrect name was supplied.), (Recommended Action: Check that the file name supplied was correct. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-EDM_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace sysdb error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace sysdb error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show sysdb trace edm location all command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show sysdb trace edm location all output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-CONNECTION_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: A peer has incorrectly attempted to establish a connection with us.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace peer context command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace peer context output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace peer verbose command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace peer verbose output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging processes msdp command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging processes msdp output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install verify packages command in IOS XR? ### Response: The 'install verify packages' command is used to verify the consistency and integrity of the currently active software packages on the router. It checks for any missing or corrupted files. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-3-INT_PCI_CORE_OVRUN ### Response: (Severity: 3), (Category: PLATFORM), (Description: QFP-CPU Bridge detected a PCIe Core overrun error. This means that the QFP-CPU Bridge PCIe core could not accept Completion errors seen by the receive interface (CA and UR).), (Recommended Action: Save log file and report this error. If the issue persists, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-3-PROFILE_OP_SETUP_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The SLA Client Library failed to setup the operations configured to use the profile following the configuration of the profile. This indicates that there was insufficient memory for the setting up of operations and these operations will not start running until they are successfully set up.), (Recommended Action: This indicates a low-memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. To resume normal operation, reconfigure the profile and the SLA Client Library will resync itself with the Profile Manager and setup the operations.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROL_DRIVER_RSP4-3-HW_ERR_INTERRUPT ### Response: (Severity: 3), (Category: DRIVER), (Description: This indicates that there is a HW error interrupt raised by IOFPGA), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-6-ERR_CHUNK_CREATE ### Response: (Severity: 6), (Category: TOPOLOGY), (Description: System failed to create and initialize memory chunk. The most likely cause is a low memory condition.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Restart CM. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-GSM_FAIL ### Response: (Severity: 7), (Category: OS), (Description: When RDS library invoked GSP api group_send_memberset , it failed. The errno returned can help in understanding the problem. The transport GSP layer returned an failure to RDS.), (Recommended Action: This is a Debug message.No action required. If the problem persists,Contact Support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-3-SIGEVENT_SEND_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_FPD-3-GET_IMG_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An image for an FPD could not be obatined so that it could be updated. The cause of the failure is indicated in the message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_AGORA_ALM_TYPE_THREE ### Response: (Severity: 2), (Category: PLATFORM), (Description: AGORA type three alarm.), (Recommended Action: If the problem persists, call your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-6-BOOT_WITHOUT_FABRIC ### Response: (Severity: 6), (Category: FABRIC), (Description: System is booting up without waiting for fabric to be up.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_MGR-7-ERR_SYSDB_EDM_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: CCSQ Sysdb Register EDM error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKS_SRVR_ENGINE-6-INFO ### Response: (Severity: 6), (Category: SECURITY), (Description: SKS server general info message with one prameter.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-QAD_EGRESS_Q_LOOKUP_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: While transmitting a packet down to the fabric, couldn't find the egress queue), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-TUPLEVALUE ### Response: (Severity: 3), (Category: SNMP), (Description: Failed to retrieve the given SysDB tuple for the given reason. This may or may not have a detrimental effect on the behavior of the SNMP agent (depends on which tuple it is).), (Recommended Action: Try to re-apply the config , if Still seen this message contact technical suppport representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-IO_PRIV_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath failed to claim IO priviledges for the thread. IO Priviledges are required for accessing certian priviledged features of the processor.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect show log location output, show controllers dpaa trace all location output and show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KIM-6-LOG_INFO ### Response: (Severity: 6), (Category: INFRA), (Description: please see show kim log for more information.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_TCAM_NOT_READY ### Response: (Severity: 3), (Category: OS), (Description: TCAM is not ready.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-UNSUPPORTED_SFP ### Response: (Severity: 3), (Category: INFRA), (Description: The SFP inserted is not supported. The port will remain in link down state as long as this SFP is kept inserted. For proper use of the port, insert a SFP that is supported.), (Recommended Action: Remove the unsupported SFP and insert a SFP that is supported.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-EVENT_BLOCK_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath received an unexpected return code from the event library.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect show log location output, show controllers dpaa trace all location output and show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBIPV4-3-CONV_ITEM_FAIL ### Response: (Severity: 3), (Category: IP), (Description: An error occurred processing a BGP convergence item operation.), (Recommended Action: This indicates a problem with publishing BGP convergence via sysdb. If the errors are seen continuously and you see problems with BGP covergence, do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the error is seen only once/twice while some sysdb processes crashed or were restarted, this might be related to that and could be considered transitory.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-REMOTE_MASTER_LEFT_LOOPBACK ### Response: (Severity: 6), (Category: L2), (Description: While running the link in OAM Loopback mode, with the local peer as the Slave, the Master peer abruptly ended Loopback mode without first informing this peer to end it. This may indicate a problem with the remote peer.), (Recommended Action: No corrective action is required. This peer has exited Loopback mode also, and the link is now back to normal operational status.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_LOS_PORTR ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_INTERNAL_CHECK_RC ### Response: (Severity: 3), (Category: ROUTING), (Description: An inconsistency in internal state was detected.), (Recommended Action: Copy the message exactly as it appears and report it to your technical service representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-ERRORLIST ### Response: (Severity: 4), (Category: MGBL), (Description: An error occurred invoking an MDA function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SUB_SIP_SHARED_DB-2-INIT_FAILURE ### Response: (Severity: 2), (Category: SUBSCRIBER), (Description: Print when Subscriber sip shared db or its clients fail to initialize necessary data structures and memories. The process cannot proceed without this module initialization.), (Recommended Action: The sysmgr will retry to start the process. If it cannot be restarted it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-4-WARNING_FIPS ### Response: (Severity: 4), (Category: SECURITY), (Description: The sshd encountered a warning condition.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTH_SRV-4-WARNING ### Response: (Severity: 4), (Category: SECURITY), (Description: Auth Service general warning message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: aaa_task-7-GENERIC_ERROR ### Response: (Severity: 7), (Category: SECURITY), (Description: Internal debugging message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-IMDR_ABORT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The CPUCTRL process aborted the IMDR upgrade process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LISP-4-MAP_SERVER_SITE_EID_PREFIX_LIMIT ### Response: (Severity: 4), (Category: IP), (Description: 'Map-server cannot create any more dynamic EID prefix ' 'entry result accept-more-specifics. Consequently, the ' 'map-register is not processed.'), (Recommended Action: 'Increase the map-server dynamic EID prefix entry limit.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ST16550-3-THREAD_CREATE_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The ST16550 UART driver was unable to create a thread for the interrupt handler.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-ESMC_RECEIVE_TIMER ### Response: (Severity: 4), (Category: L2), (Description: An error occurred when attempting to re-arm the ESMC SSM receive timer for the specified interface. Any SSMs received on the interface will continue to be handled, but any future peer timeouts (i.e. loss of SSMs) on the interface will go undetected.), (Recommended Action: Restarting fsyncmgr on the card on which this message was seen may fix the problem. If the message continues to be seen, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBMIRROR-3-ERR_MAX_DIRS ### Response: (Severity: 3), (Category: MGBL), (Description: 'mirror encountered error, see message for more details'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-RDDR_FIFO1_PAR_ERR ### Response: (Severity: 0), (Category: PLATFORM), (Description: RxDDR 1875 to 200 FIFO 1 parity error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-3-TIMER_FAIL ### Response: (Severity: 3), (Category: DIAG), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the screen and gather the output of show tech-support and any other relevant information. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-4-DSCP_SET ### Response: (Severity: 4), (Category: IP), (Description: An error occured while trying to set dscp value to socket. Telnet will start without spefified dscp value.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-CHKPT_TABLE ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while creating/accessing chkpt table. This will result in the PD code to exit.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-CDR_DISPATCH_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric:CDR event message attach failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND-3-ERR_SLAAC_RIB_ROUTE_ADD ### Response: (Severity: 3), (Category: IP), (Description: Cannot add default route for auto configuration, there is some error between ND and RIB interaction.), (Recommended Action: auto configuration works only on management interfaces so restart IPv6 ND and RIB process on active RP should help.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ERR_SYSDB_SET ### Response: (Severity: 3), (Category: MGBL), (Description: Nvgen server failed to set an item in sysdb database. The item name is part of the error. This may result in failure to generate running config properly in show run command. Or an impact may be seen during the internal config backup.), (Recommended Action: Collect the show logging output, show nvgen trace output, show runnning output, show config history and show tech-support sysdb. Contact TAC representative with this information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-NEXTHOPS_TRAVERSE ### Response: (Severity: 3), (Category: ROUTING), (Description: Unexpected error unregistering client next-hops. This may lead to a slow memory leak.), (Recommended Action: If RIB is leaking memory, try restarting it. *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCM_SWITCH-3-SEEK_BCM_LOG_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Fseek failed for the provided offset for that bcm_log file. The error message indicates the failure reason. This is related to log file and it has no imapct on system functionality.), (Recommended Action: Please do bcm_process restart to recover from this. 'process restart bcm_process location < >' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-4-ERR_DEST_CONN ### Response: (Severity: 4), (Category: FABRIC), (Description: This is to indicate that a node has lost connectivity to a plane. Most likely, back plane connectivity between the node and the fabric card has failed.), (Recommended Action: To fix the issue please reinsert the card and make sure it seats well. If that doesn't help than verify the integrity of mid-plane pins.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSCMEDIA-3-GET_MY_NODEID_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: DSC Media DLL failed to get the nodeid. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does priority inheritance solve the priority inversion problem with mutexes? ### Response: Priority inversion occurs when a high priority thread is blocked waiting for a mutex held by a low priority thread. With priority inheritance, when a high priority thread blocks on a mutex, the thread holding the mutex temporarily inherits the higher priority. This allows it to complete its work and release the mutex more quickly, minimizing the delay to the high priority thread. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-6-REMOVE_ABORTED ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Package remove requested on this satellite has been aborted, as requested by the user. Run 'show nv satellite status' for more information about the current state of the satellite.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of a BGP route-map on IOS? ### Response: A BGP route-map on IOS is used to filter and modify BGP path attributes for routes being sent to or received from a neighbor. It allows matching on prefix, AS path, community, etc. and setting attributes like MED, local preference, community, etc. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-4-ERR_CHKPT_INIT ### Response: (Severity: 4), (Category: FABRIC), (Description: Ingressq Checkpoint Init error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-TEST ### Response: (Severity: 4), (Category: MGBL), (Description: An error occurred invoking an MDA function. This could be because the object does not exist or has the wrong type. Or because the verifier did not allow the change. The details are in the error string.), (Recommended Action: Check that the object to set exists and has the same type as it is being set to. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ETHER-2-HW_ERROR ### Response: (Severity: 2), (Category: L2), (Description: A problem is encountered at hardware layer for a given port. The traffic may start getting dropped after this error message.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-SETPRIO_FAILED ### Response: (Severity: 3), (Category: SECURITY), (Description: Attempt to change priority failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-0-PEX_INT_BIT ### Response: (Severity: 0), (Category: PLATFORM), (Description: Device driver detected a pex switch error), (Recommended Action: Please try to correct problem by reloading board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-3-PWR_EXCEEDED_WARN ### Response: (Severity: 3), (Category: PWR_MGMT), (Description: The chassis power usage has exceeded the configured warning threshold.), (Recommended Action: Ensure that adequate power is available for the chassis.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SGT2_FIFO_OFLOW_1_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress sgt2 fifo overflow on xaui-1 bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OT-3-LIB_UNAVAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: Failed to dynamically load a dependent library. It is unavailable.), (Recommended Action: Install the package that has the library. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_12_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_CLIENT-4-LICENSE_GOING_TO_EXPIRE ### Response: (Severity: 4), (Category: LICENSE), (Description: The term of the license is about to expire.), (Recommended Action: The customer should renew the expired licenses.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp log neighbor changes' command in IOS XR BGP configuration? ### Response: The 'bgp log neighbor changes' command is used to enable logging of BGP neighbor status changes. When enabled, BGP will generate a log message whenever a BGP peer enters or leaves the Established state. This is useful for monitoring the stability of BGP sessions and for troubleshooting connectivity issues. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_SCP_READ_WRITE ### Response: (Severity: 3), (Category: SECURITY), (Description: Error in SCP read/write.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_TRAFFIC_ALERT-0-GRP_ALM_EMERG ### Response: (Severity: 0), (Category: SERVICES), (Description: The monitored flow has traffic issues as indicated by the react trigger. The problem is introduced either at some upstream router or even at the traffic source itself. Alternatively, a configuration mismatch between the traffic source and this router (for the flow data rates etc) can cause this error.), (Recommended Action: Check to see if traffic source is indeed sending traffic. Check that the traffic characteristics defined at the source match that on the monitoring router. Trace the traffic flow upstream to the source and verify flow-mon statistics at each applicable hop. Check for packet drops for the flow at intermediate hops - between source and the monitoring router) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-FILE_TOO_SMALL ### Response: (Severity: 7), (Category: OS), (Description: A file is found to be too small size than expected.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'preferred-path' command in MPLS TE configuration? ### Response: The 'preferred-path' command is used to specify the preferred path for an MPLS TE tunnel. It allows the operator to influence the path selection for the tunnel by specifying a list of explicit hops or a dynamic path option based on TE attributes such as bandwidth, priority, and affinity. This command is useful for traffic engineering and for optimizing the network performance. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR-7-ERR_RRW_UNLOCK ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server failed to release rrw lock to the request record area in shared memory. This is a fatal error, the process will automatically restart.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: orrspf-4-LTRACE_INIT_ERR ### Response: (Severity: 4), (Category: ROUTING), (Description: The ORRSPF process failed to initialize ltrace correctly.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-1-ALL_FANTRAYS_REMOVED ### Response: (Severity: 1), (Category: PLATFORM), (Description: Two possibilities to this message 1) An alarm has occured. Software has detected that all fan trays have been removed from the chassisbut, but gives user 45 seconds to insert another tray. If no action is taken within 45 seconds, the chassis will be shut down. 2) A previously occured alarm has been cleared. Software has detected that all fan trays were removed which would have shut down the system. But one fan tray was put back within 45 seconds, thus removing the need to shut down the system.), (Recommended Action: Two possibilities to this message. 1) An alarm has occured : Insert a fan tray within 45 seconds. 2) A previously occured alarm has been cleared : *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-7-BAD_OPEN ### Response: (Severity: 7), (Category: PLATFORM), (Description: Open of file failed), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check the card is inserted properly and a Cisco approved device if it is externally accessible. Capture 'show filesystem ' together with console log.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-7-BADRAWINIT ### Response: (Severity: 7), (Category: MEDIA), (Description: Could not spawn a thread to handle nvram raw partition request), (Recommended Action: Restrat nvram server. If that too fails Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOADPATH-3-LIB_INIT_FAIL ### Response: (Severity: 3), (Category: INSTALL), (Description: 'Failed to initialize the library. The system may not ' 'function properly. '), (Recommended Action: 'Try restarting the 'instdir' process to recover. ' 'From exec mode - 'process restart instdir'' 'If the issue is still seen contact TAC.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-APS_EVENT ### Response: (Severity: 3), (Category: OS), (Description: An unexpected error occurred.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VRRP-3-ERR_INDEX ### Response: (Severity: 3), (Category: IP), (Description: The VRRP process failed to obtain the snmp index for this interface. There may be a problem with the connection to certain IOSXR services.), (Recommended Action: Retry the configuration on this interface. If this still fails then do the following. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-7-READ_FAILED ### Response: (Severity: 7), (Category: OS), (Description: RDS library uses ENS/GSP services to read/write data. While using ens_read API to read, it returned failure. Underlying GSP/ENS might have some problem), (Recommended Action: This is a Debug message. No action required. If problem persists,contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSI_MASTER-2-MEM_ALLOC_FAILURE ### Response: (Severity: 2), (Category: OS), (Description: RSI Master terminated due to lack of memory for a critical operation.), (Recommended Action: It is detected that the system is running under very low memory condition. Collect RSI traces and restart rsi_master process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIAAPI-4-INVALID_PARM_DRIVER_EXIT ### Response: (Severity: 4), (Category: MEDIA), (Description: An invalid parameter value was passed to the media driver when it exits.), (Recommended Action: Report this message to TAC. Capture console log, 'show media' and 'show media trace' output.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-SATELLITE_SLA_PROGRAMMING_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An error was encountered by the Satellite while attempting to program the MEP for the specified interface.), (Recommended Action: Try un-configuring the MEP and re-configuring it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-7-FAIL_SYSDB ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_2_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_2 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LSPV-7-MSG_EVENT ### Response: (Severity: 7), (Category: ROUTING), (Description: An error occurred in event manager or event connection operations. The text of the message displays the failed operation with error code.), (Recommended Action: Wait a few minutes and attempt the operation again. If the error persists, attempt to restart the failing process (LSPV_SERVER).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_9_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-6-PLANE_DEST_UNREACHABLE ### Response: (Severity: 6), (Category: FABRIC), (Description: This message gives additional information related to a plane in multicast-down state. It reports the number of operating fabric links from the plane to the destination. The threshold reported is the number of fabric links that are required for the destination to be considered reachable.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-TABLE_INIT ### Response: (Severity: 3), (Category: OS), (Description: Unable to initialize table.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_COM_NETIO-7-DEBUG_INIT_EVENT ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when initializing debug.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_C_SHIM-6-CREATE_SHIM_ENTRY ### Response: (Severity: 6), (Category: L2), (Description: Creating shim info entry for the given interface handle), (Recommended Action: *None*.Informational message only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-1-HFR_FIB_OOR_LIMIT_EXCEEDED ### Response: (Severity: 1), (Category: PLATFORM), (Description: CEF on the node has detected that the number of routes has exceeded prescribed limits. Any further increase could cause CEF to block the routes from being programmed in hardware.), (Recommended Action: Take immediate action to delete routes from the system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFDIAGBASE-3-CTX_ERROR ### Response: (Severity: 3), (Category: DIAG), (Description: The diagnostics software detected an invalid or null pointer was passed to the named function. This is a serious error and could indicate memory coruption or a bug in the software. This is not a service impacting error.), (Recommended Action: Check the log ('show logging') to determine if there are any other related error messages. Also, please check Bug Navigator ( https://tools.cisco.com/bugsearch?referring_site=btk ) to search for any bugs in this area. Copy the error message exactly as it appears on the screen and gather any relevant information about the circumstances. Also collect the information from 'show logging' and 'show tech diagnostics' commands. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UCP_OUNI-7-ERR_INTERNAL ### Response: (Severity: 7), (Category: ROUTING), (Description: An internal system error occured.), (Recommended Action: Please provide the show trace output, show run and show mpls optical output to the TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-7-RM_ATTACH ### Response: (Severity: 7), (Category: OS), (Description: The syslog_dev process has failed to attach a Resource Manager to an Event Manager.), (Recommended Action: Collect the output of show tech-support, show processes , show memory, debug event-manager attach job <> and show watchdog memory-state from the location the error message comes from. If the error message doesn't persist, it can be ignored. If the error message persists,call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-PROXY_EVENT_CONN_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_RX_DESKEW_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_RX_DESKEW_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-4-ACCT_FAILURE ### Response: (Severity: 4), (Category: SECURITY), (Description: Failed to send an accounting record to RADIUS or TACACS+ server), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-3-STBY_INIT_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to initialize locald on standby node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_BDI_DEME ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_SWITCH-6-ERRDIS ### Response: (Severity: 6), (Category: PLATFORM), (Description: Front panel SFP port is UDLD Uni-Directional, check sfp/fiber for errors), (Recommended Action: 'Check if the media (fiber / sfp) has any errors') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEMLOG-3-MALLOC ### Response: (Severity: 3), (Category: OS), (Description: A call to malloc failed.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-3-INT_SBE ### Response: (Severity: 3), (Category: PLATFORM), (Description: QFP-CPU Bridge detected a single-bit memory error (SBE).), (Recommended Action: Save log file and report this error. If the issue persists, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-PROCESS_PKG_DEF ### Response: (Severity: 3), (Category: OS), (Description: The virtual service package for the named virtual service has failed to be validated and the virtual service will not run.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_MA-4-FA_BATCH_ERR ### Response: (Severity: 4), (Category: SERVICES), (Description: One or more errors occurred in RSPP MA, the service diversion management agent, during the processing of a set of configuration detailing the failure policies to be applied in the event of service failure. The configured failure policies may now not be implemented on the node indicated. The error string will give more detail on the type of error that has occurred.), (Recommended Action: For non-resource errors, removing and adding back the configuration that prompted the message may remove the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the error is a resource error this will be indicated in the error description given. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_A_DATABUS_STUCK_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI-A databus stuck on bridge instance-3.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-3-ERR_AUTO_TUN_MESH_TUN_LIMIT_EXCEEDED ### Response: (Severity: 3), (Category: ROUTING), (Description: The creation of the auto-mesh tunnel aborted since it would have exhausted the tunnel interface scale limit), (Recommended Action: Reduce configured/auto tunnels to below the system scale limit) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_MCAST_EDM-7-GEN_FAILURE ### Response: (Severity: 7), (Category: ROUTING), (Description: VIKING-MCAST library encountered error during setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-7-ERR_LWM_FAIL ### Response: (Severity: 7), (Category: L2), (Description: An internal error was detected when trying to send a LWM message. There are several scenarios which can cause this error condition. Error message describes the exact cause.), (Recommended Action: No action is required. The process retries automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-7-SHIP_PERF_BIND_FAIL ### Response: (Severity: 7), (Category: SYSDB), (Description: Registering performance counter with stats infra failed.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-6-CONTROLLER_CREATE ### Response: (Severity: 6), (Category: OS), (Description: Controller Creation Successfull.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure RSVP path MTU discovery in Cisco IOS XR? ### Response: To configure RSVP path MTU discovery, use the 'rsvp mtu-discovery' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#rsvp mtu-discovery <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-4-SIGNAL ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message provides information about the fault occurred on the interface.), (Recommended Action: The message is just for information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCAM_MGR_LIB-3-INTERNAL_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An internal error occurred in TCAM Manager which involves exiting the process. After the TCAM Manager process restarts, the error should have been cleared. *DDTS*), (Recommended Action: Collect the configuration, syslog and coredump file. Attach them to the ddts. After the process restarts automatically, the error should have been cleared and no user action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_SYSDB_REG_VERIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP local AS feature? ### Response: The BGP local AS feature allows a router to appear to be a member of a second AS in addition to its real AS. This is useful in situations like AS migrations. The local AS is added to the AS path of inbound updates and removed from outbound updates. It is configured with the neighbor local-as command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you verify that the IOS XR software installation was successful? ### Response: After the TURBOBOOT process completes and IOS XR starts up, you can use these CLI commands to verify the installation\n- `show install active summary`: Shows the active software packages\n- `show install committed summary`: Shows the committed software packages\n- `show version`: Displays the IOS XR version and other system information\n- `show inventory`: Lists the hardware components and their status\n- `show platform`: Displays information about cards and modules in the system\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-POWER_DOMAIN_2_FAILURE ### Response: (Severity: 3), (Category: DRIVER), (Description: Failure in power domain 2 indicates that the ASICs running on that power domain will not be operations. ASICs on this power domain are usually related to data path features, so although the boards CPU is running (from power domain 1). The card will not function correctly, the SysAdmin VM might continue to function to allow collection of debug info.), (Recommended Action: This is an indication of HW failure and will require RMA of the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-4-ERR_ASIC_DROP ### Response: (Severity: 4), (Category: FABRIC), (Description: Ingressq received a packet with SOP/EOP/MAC error It is primarily caused by either software or mac issue.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_VCM-3-PTP_VC ### Response: (Severity: 3), (Category: L2), (Description: Point-to-point (PTP) subinterfaces only allow one PVC and an attempt to create a second PVC is being rejected), (Recommended Action: Remove the old PVC before creating the replacement, or use a multipoint subinterface instead) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_ACL-7-IPACCESSPTHREAD ### Response: (Severity: 7), (Category: ACL), (Description: The mutex used to protect access to the ACL data structure could not be locked or unlocked. The error message will include details of the particular failure. Possible causes of failure are the mutex is corrupted, has not been initialised or is being accessed recursively (this is not allwowed). Because the mutex could not be used the process may restart to recover from the failure.), (Recommended Action: Please get the information specified under the component required_info and call your Cisco technical support representative and provide the representative with the gathered information with this error message text. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLDR-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: XRv sysldr error message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL_GRE_EA-3-INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the platform specific code software to indicate anomolies while initializing GRE Feature. This error is most likely caused by a temporary situation within the feature code. %s - indicates the reason for the failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-7-ARG_MISMATCH ### Response: (Severity: 7), (Category: ROUTING), (Description: The user is trying to do an operation in which the number of arguments entered does not match the number of argument expected.), (Recommended Action: Correct the number of parameters that are passed in. Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-3-LINUX_LOOPBACK_ADDRESS_REMOVED ### Response: (Severity: 3), (Category: INFRA), (Description: XLNCd is responsible for keeping the networking stacks for IOS XR and Linux synchronized. Certain IOS XR interfaces only have L3 reachability, provided by having their IP addresses added to the Linux loopback device in the network namespace corresponding to the IOS XR VRF the address is configured in. This message indicates that a XLNCd believes an address that it has added to a Linux loopback device has been removed unexpectedly. The removal could have been triggered by user action, or a Linux script or process.), (Recommended Action: If the address was removed intentionally because no Linux applications require L3 reachability for that address then no action is required. If the removal was unexpected then the immediate problem can be addressed by re-adding the address to the Linux loopback device. IPv4 addresses can be added using run ip netns exec ip addr add dev lo IPv6 addresses can be added using run ip netns exec ip -6 addr add dev lo To avoid the problem recurring, the trigger for the removal should be investigated by consulting available Linux logs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to verify the status of an MPLS L2VPN xconnect? ### Response: To verify the status of an MPLS L2VPN xconnect, use the 'show l2vpn xconnect' command. show l2vpn xconnect <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-2-ERR_EES_INIT ### Response: (Severity: 2), (Category: FABRIC), (Description: Rack num could not be determined because platform_get_my_nodeid failed.), (Recommended Action: Whenever this happens, fgid_server will dump a core file. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_IMC_CAPS_DATAPATH_CONTROL ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_SWITCH-6-BADSFP ### Response: (Severity: 6), (Category: PLATFORM), (Description: nV Edge Control ports needs Cisco supported SFPs.), (Recommended Action: 'Plug in a Cisco supported 1Gig SFP') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-ADD_SYMLINKS_FILE ### Response: (Severity: 3), (Category: OS), (Description: A error occured while processing a QSM configuration file. This could be due to a problem with the installed media or file system damage. QSM will continue startup-up, but some system functionality may be impared.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UDP-3-INIT_ERR ### Response: (Severity: 3), (Category: IP), (Description: An software error occurred while starting up of UDP process. If this occurred during process startup, then the process may be restarted.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_4_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_4 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-3-SAM_CFG_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: SAM command operation error.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-BUS_ADRERR ### Response: (Severity: 4), (Category: OS), (Description: The CPU is instructed by software to read or write a specific physical memory address that is non-existent), (Recommended Action: No action required. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: rspp_rio_netio-3-CAPS_CONTROL_FAILED ### Response: (Severity: 3), (Category: SERVICES), (Description: The service ingress diversion NetIO DLL capsulation function failed. Service ingress diversion in NetIO for the specified interface will not function properly.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-3-STACK_SIZE_INVALID ### Response: (Severity: 3), (Category: OS), (Description: Stack size of target process is invalid. If the stack size is zero then the core dump will not have stack related information of the target process.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CSCMIB-7-INVALID_ARG ### Response: (Severity: 7), (Category: SNMP), (Description: The MIB has reached an unexpected state, and will not be able to service the current request.), (Recommended Action: If the message recurs continuously, please restart the process emitting these messages. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDS_DB-3-COMPARE_CLIENT ### Response: (Severity: 3), (Category: OS), (Description: Comparison of the client failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HBAGENT-2-CAUSE_HBLOSS ### Response: (Severity: 2), (Category: PLATFORM), (Description: User ran a heartbeat test utility to create heartbeat loss.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REPLICATOR-7-LOCKING ### Response: (Severity: 7), (Category: LIBRARY), (Description: The replicator library has either failed to aquire or release a lock.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-5-SR_POLICY_INVALID_DROP ### Response: (Severity: 5), (Category: OS), (Description: An SR policy has entered/exited from invalidation drop state), (Recommended Action: Verify path validation and constraints.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHERNET-3-INTERNAL_ERROR ### Response: (Severity: 3), (Category: L2), (Description: An internal operation failed despite multiple retries. This could be due to an external service being unavailable.), (Recommended Action: This error message indicates an internal operation has failed and the retries have been unsuccessful. More information as to which operation has failed is available in trace.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-MBI_CONFIG_INCORRECTLY_CHANGED ### Response: (Severity: 7), (Category: INSTALL), (Description: Configuration definitions have changed for an MBI file and this has only done by changing the MBI config namespace file, not by moving the MBI config namespace file out of the MBI as is required by the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-POWER_ZONE_DOWN ### Response: (Severity: 4), (Category: PLATFORM), (Description: This indicates that the given power-zone has gone down, and therefore the related nodes are being brought down.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-ERR_INVALID_POLICER_RATE_BURST ### Response: (Severity: 4), (Category: OS), (Description: Policer burst is set to more than Policer Rate.), (Recommended Action: No action is needed. Incorrect burst value is auto corrected to the policer rate.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LNS_EA-4-ERR_INIT ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: A failure occured during the initialization of the process. The process will restart which should recover the situation.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-AREALOST ### Response: (Severity: 4), (Category: ROUTING), (Description: Too many IS-IS areas--cannot route to area AREA-ADDRESS. This system has exceeded the limit of three learned area addresses. The largest address AREA-ADDRESS has been dropped from the list of active areas.), (Recommended Action: Reduce the number of area addresses in the routing area.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-5-SC_PKDREAD ### Response: (Severity: 5), (Category: SYSDB), (Description: An error occurred while preparing to read instructions from the command line.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AVSM_APIV-3-REGISTRATION_TIMEOUT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The registration of APIV modules has not completed. The specified timeout period has reached and is this event will be considered as a failure that will trigger a reload of the affected card.), (Recommended Action: Contact Cisco TAC to diagnose the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-CHKPT_ALLOC_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Checkpointing is a mechanism to update the redundant RSP with the current configuration and status of the system to help takeover in case of a failover. The checkpoint mechanism needs to be initialized for Sync-controller to update the standby RSP with current frequency syncronization status. This failure could be because of memory allocation failure.), (Recommended Action: * REDUCE *) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CSI_NETIO-5-INCORRECT_SAVE_DATA_LEN ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: CSI DLL saves data across DLL upgrades. It expects the length of saved data to be same before and after upgrade, else it would cause netio to take default action (to restart) for upgrade to take effect.), (Recommended Action: This message indicates that netio will take default action to restart as 'csi netio' dll does not support dll upgrade with different saved data length. No further action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-4-SYSMGR_GET_NODE_STATE ### Response: (Severity: 4), (Category: ROUTING), (Description: An error occurred while trying to get the system [active/standby] state. A state of REDUNDANCY_UNKNOWN will be assumed. This process also registers for notification of changes to the [active/standby] state. Thus, the state can be determined by this means as well. Failure to receive notification for either one of these means could result in this process not functioning properly. Note At least one of the processes in an active/standby pair must be active in order to assure proper functioning.), (Recommended Action: Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_INT_PWR_SUPPLY_ALARM ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAQFPBridgeCtrl-1-PARITY_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: SPA Bridge ASIC detected a Parity error.), (Recommended Action: Reboot the card. If the problem persists, report the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FRMIB-3-SYSDB ### Response: (Severity: 3), (Category: L2), (Description: This message indicates the FR MIB library fails to perform a SYSDB operation. Trap initialization will be affected. The error could be related to the following: - failed event attach - timer tree initialization failure - Trap handler registration failure - EDM handler registration failure - IPC issues - Trap OID conversion problem), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-READ_POWER_SHELF_TYPE_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: We are unable to read the power shelf backplane EEPROM for some reason. Need to check the programming of the backplane.), (Recommended Action: Check that the power-shelf is seated correctly, and that the backplane EEPROM is programmed correctly. In the admin mode, use 'show diag power-supply eeprom-info' to check the contents of the EEPROM.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_STARTBULK ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-5-ASIC_ERROR_SPECIAL_HANDLE ### Response: (Severity: 5), (Category: PLATFORM), (Description: An ASIC error that need special handling has occured and been handled.), (Recommended Action: *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_OUT_MEM_UCORR_ECC_ERROR_LNK3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast output memory uncorrectable ECC error on link 3), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE2_CODE_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE2_CODE_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WAN_INARP-3-UNKNOWN_IDBTYPE ### Response: (Severity: 3), (Category: L2), (Description: Information about InARP interfaces has become corrupted.), (Recommended Action: Restart the main processes (containing the InARP DLL) If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VLANIFMIB-4-BAG ### Response: (Severity: 4), (Category: SNMP), (Description: The VLAN Interface table relationship MIB encountered an error while encoding / decoding some data. It is likely that an SNMP query that was in progress will not have been completed.), (Recommended Action: Retry the operation that caused the message to be displayed. It may help to restart the SNMP process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-2-SYSTEM_STATE_UNSTABLE ### Response: (Severity: 2), (Category: INFRA), (Description: An operation to reload the system to apply the latest software has failed. This has left the system in an unstable state that requires user interaction. The user needs to reload the system. This will cause the system to return to the fallback software.), (Recommended Action: For the reload error: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Once the required info has been collected, then reload the system and re-try the install operation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_140G_POD-3-LOW_3_3VCC ### Response: (Severity: 3), (Category: FABRIC), (Description: The POD detects a low in 3.3Vcc voltage. The POD might not be functioning properly, and can cause cell drops or corruption in the rx or tx link associated with the POD.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-SYSDB_BIND_FAIL ### Response: (Severity: 7), (Category: OS), (Description: Dumper keeps various config related data in sysdb. Here dumper could not connect to sysdb), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging 5. show-tech sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-BLOBBIFIER_ERROR ### Response: (Severity: 7), (Category: INSTALL), (Description: An invalid parameter may have been unexpectedly passed to the Install infrastructure. This is a coding error. The current request or operation will not be completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-LSDB_ERROR ### Response: (Severity: 4), (Category: ROUTING), (Description: OSPFv3 detected an error with its link state database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_SVR_TOPAZ-7-ERR_RRW_LOCK ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server failed to aquire rrw lock to the request record area in shared memory.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL-3-NO_TOD_MSG ### Response: (Severity: 3), (Category: PLATFORM), (Description: No TOD messages are being detected on the GPS port UART receiver.), (Recommended Action: 1) Ensure cable connection between the configured interface port and external equipment.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_4P_OC192-3-DRV_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: PLIM driver encountered the annunciated error during the driver initialization. The System Manager process (sysmgr) will automatically respawn the (plim_4P_oc192) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: OS), (Description: Otn-framer driver failed to create an event manager during the driver initialization. The driver will be non-operational due to this error.), (Recommended Action: The driver will escalate the error to the Fault Management (FM) entity for further action. Verify that the driver will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE interarea tunnels feature? ### Response: The MPLS TE interarea tunnels feature allows MPLS TE tunnels to be established across IGP area boundaries. This enables TE to operate in multi-area environments. Interarea TE tunnels comprise hops in different IGP areas and are signaled as a contiguous end-to-end LSP. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-INIT_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: An error was encountered while the specified process was initializing. The error message contains details about the source of the error.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-MAIN_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during main thread initialization, causing the process to terminate. Check the details of the error message for more information.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-WD_METRIC_NOT_CONF ### Response: (Severity: 4), (Category: ROUTING), (Description: The specified interface and topology has been configured with a metric value that requires metric-style wide to be configured for the relevant level.), (Recommended Action: Configure metric-style wide for the topology and area.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: c2c_aif-3-ERR_SW ### Response: (Severity: 3), (Category: PLATFORM), (Description: The C2C AIF library encountered an error which it cannot resolve.), (Recommended Action: An error would be reported to the client application which should handle this condition appropriately. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_ASR9K_LIB-3-FAILURE_TO_RETRIEVE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The platform library service call to find the config tuple for svd platform enable has failed. The calling application handles it appropriately.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL-3-BAD_CHAIN ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: An invalid chain type was received by the chain builder. This is an internal error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYS-5-TABLEERR ### Response: (Severity: 5), (Category: MGBL), (Description: An internal table entry became corrupted.), (Recommended Action: Copy the message exactly as it appears, and report it your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-REMAP_ERR ### Response: (Severity: 3), (Category: OS), (Description: An error has occurred when shmwin was trying to remap the memory. Shmwin server needs the memory to operate. Process will exit when it has encountered the error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture process core of shmwin_svr) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: APPMGR-3-RELAY_CLEANUP_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: The IOS-XR appmgr has errored or failed while attempting to cleanup a relay running on the previous active RP prior to switchover.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_PEER_RSP ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlma-3-L2VPN_DISCONNECT_FAILED ### Response: (Severity: 3), (Category: L2), (Description: When the VLAN MA notices that it has lost its connection to the L2PVN Manager process, it needs to update its database to reflect this. This error message indicates that this the update failed. The only expected scenario that could cause the error is a low memory condition.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFC_WATCHDOG-5-PKT_DROP ### Response: (Severity: 5), (Category: PLATFORM), (Description: Priority Flow Control (PFC) enabled queues(lossless) are experiencing drops.), (Recommended Action: Check if drops are due to headroom exceed or due to queue shutdown by PFC WD expiry. Headroom exceed drops can be seen as Rx Drop Data Frames in show controllers priority-flow-control statistics. Queue shutdown drops due to watchdog expiry can be seen as Dropped Packets in show controllers priority-flow-control watchdog-stats. Investigate why there is a congestion experienced on the lossless queue that is leading to drops.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-4-WARN_MEM_ALLOC ### Response: (Severity: 4), (Category: SNMP), (Description: Due to a low memory condition we could not enable (or disable) the specified traps or we could not register to receive the specified MIB notifications. Until available memory is increased and the SNMP process is restarted, these notifications will not be generated by the agent.), (Recommended Action: check the state of prcess from below CLI's 1)'shmw snmpd process' 2)'show process block | i snmpd' Please restart snmpd process if still showing the error conatact technical support representative with required info. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-7-ERR_LWM_REPLY ### Response: (Severity: 7), (Category: PLATFORM), (Description: Interrupt controller LWM reply error), (Recommended Action: Please attempt to correct the error by restarting the process. Issue the command in exec mode -process restart longbeach If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_FSDB_FADB_LTRACE-3-EVENT_INIT_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: The FSDB FADB ltrace lib failed to initialize the events ltrace), (Recommended Action: Search the event logs for events/errors related to the failure reason. Ltrace usage is common to overall system. If there are failures here then other processes may also exhibit similar problems. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_SOCKET-2-INIT ### Response: (Severity: 2), (Category: L2), (Description: During process start up an unrecoverable error occurred. The component will exit and should be restarted by the System Manager.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_PAIRING-3-ERR_DSC_NODEID ### Response: (Severity: 3), (Category: PLATFORM), (Description: Got invalid DSC node while searching to run the DRP pairing process on DSC node. Software will automatically do recovery by restarting the drp_pairing process.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: KEYCHAIN-6-KC_TYPE6_MK_UPDATE_START ### Response: (Severity: 6), (Category: SECURITY), (Description: kc_srvr has received a masterkey update event. All the existing type6 passwords will be re-encrypted using the new key.), (Recommended Action: This is just an information. Note if the migration is successfully completed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-FPGA_SIPPI_LOS ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected a timeout on some bus), (Recommended Action: Please try to correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VEEA-4-BCMDPA_L1_PFC_UNSUPPORTED_HW_PROFILE ### Response: (Severity: 4), (Category: PLATFORM), (Description: BCMDPA L1 port PFC config failure.), (Recommended Action: Unsupported config, fix config.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-3-MULTIPLE_STUCK_BITS ### Response: (Severity: 3), (Category: PLATFORM), (Description: Multiple stuck bit is detected in DRAM.), (Recommended Action: In-field hardware repair. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBC_RSRCMON-6-INFO ### Response: (Severity: 6), (Category: SERVICES), (Description: The system is in normal state. Alarms have been cleared.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFC_WATCHDOG-5-MAX_SHUTDOWN_MULT_EXCEED ### Response: (Severity: 5), (Category: PLATFORM), (Description: Due to hardware limitation, a queue should not be completely stuck for more than 6-7s. Hence, PFC WD triggered shutdown action is auto adjusted to be enforced within that interval and the user is warned of the adjustment.), (Recommended Action: This is just a warning msg, the shutdown multiplier is auto-adjusted to supported max. But it is advised to configure PFC WD config such that interval + (shut-mult *interval) <= 6secs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-MULTIPLE_IPV4_HOME_ADDRESS_NOT_SUPPORTED ### Response: (Severity: 3), (Category: IP), (Description: The PBU received has multiple HoA Request options. This is invalid as the PBU can contain only a single HoA request option.), (Recommended Action: If the issue is seen repeatedly, do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-3-TSP_A_PWM_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: TSP decoder A PWM error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-6-IPARMS_UPDATE_ERR ### Response: (Severity: 6), (Category: ROUTING), (Description: Internal error), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG_PLAT-7-NO_MEM ### Response: (Severity: 7), (Category: INSTALL), (Description: The requested operation could not be accomplished because of a low memory condition.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-FALAFEL_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: The driver failed to initialize falafel with the above reason.), (Recommended Action: The asic will restart and try to recover. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GATM-6-ADMN_STATE_INFO ### Response: (Severity: 6), (Category: L2), (Description: Informs about the admin state change. first %s --> The method name next %s --> TRUE/FALSE %x --> interface handle.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to monitor RSVP TE tunnels in Cisco IOS XR? ### Response: To monitor RSVP TE tunnels, use the 'show mpls traffic-eng tunnels' command in EXEC mode. RP/0/RSP0/CPU0:router#show mpls traffic-eng tunnels <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-2-ETHSERVER_DOWN ### Response: (Severity: 2), (Category: PLATFORM), (Description: The card could not send a heartbeat reply to the RSP because the ethernet server connection is down. The card will continue to attempt to respond to the heartbeat requests from the RSP. If the RSP continues to not receive these messages due to this particular or any other failure, it will issue a command to reset this card.), (Recommended Action: Please collect the following information and contact your Cisco technical support representative. 1. The console output of the active RSP from user login till the end. Please make sure the above error message(s) are included. 2. (admin)#show install trace mbi-hello location 3. The output of the following CLI commands:) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-CAP_4BYTEAS ### Response: (Severity: 4), (Category: ROUTING), (Description: Possible misconfiguration with 'capability 4-byte-as suppress'. This configuration can be inherited from either a neighbor-group or a session-group by a neighbor whose remote-as is a 4-byte as number. Suppress should be off for such neighbor.), (Recommended Action: Check the bgp configuration. Remove the 'capability 4-byte-as suppress' configuration or disable it to prevent getting inherited from the neighbor-group or a session-group) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-3-EVM_THREAD_INIT ### Response: (Severity: 3), (Category: HA), (Description: An error occured when attempting to initialize the event manager thread.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-2-PLIM_DCEN ### Response: (Severity: 2), (Category: PLATFORM), (Description: PLIM DCEN jumper installed. PLIM will power up, but will not be fully operational.), (Recommended Action: Please collect required_info and remove the jumper. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_IF ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error encountered in RIP interface module.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ether_spa_dwdm-3-PLL_NOT_LOCKED ### Response: (Severity: 3), (Category: L2), (Description: The SPA driver failed to initialize the PLL.), (Recommended Action: Try Reseating the SPA if the problem persists even after reseating collect the output of CLIs and contact TAC. 1. 'show interfaces TenGigE <>/<>/<>/<>' 2. 'show controller TenGigE <>/<>/<>/<>' 3. 'show logging') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_INFRA-3-EVENT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message which indicates the blocking of an event.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_CONFIG-7-ERR_MEM_ALLOC ### Response: (Severity: 7), (Category: OS), (Description: Memory running low), (Recommended Action: Information only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_EXEC-6-SET_CAUSE_FAIL ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-5-ERR_PRM_STATS_ALLOC ### Response: (Severity: 5), (Category: OS), (Description: It failed to allocate HW counters. It may be because of running out of HW counters or encountering internal error.), (Recommended Action: Disable the numbers of non crucial services which use HW counters.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_AGENT-3-EVM_EVENT_BLOCK_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in the event loop. It may be possible to rectify it by restarting the process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAMETER_BASE-4-DIA_PEER_UNRESPONSIVE ### Response: (Severity: 4), (Category: SECURITY), (Description: Pending messages for diameter peer. Check 'show tcp brief' for diameter for peer connection.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-MAC_1_TX_FIFO_OFLOW_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: MAC on NPU-1 had transmit fifo overflow on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-ERR_EMPTY_SESSION ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error, Session node does not include any ipsec and ike SAs, This indicates an internal data structure inconsistency.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-WARNING_INFO ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the ASR9K platform FIB specific code software to indicate anomolies that are not FATAL. This error is most likely caused by a temporary situation, so is unlikely to re-occur.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace all loc ). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How is an IOS XR release version identified in the image or PIE filenames? ### Response: An IOS XR release version is identified by a numerical suffix value added to the image or PIE filenames. For example, a 3.6.0 suffix identifies an IOS XR mainline release 3.6.0. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_INFRA-3-register_failed ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to register with sysdb), (Recommended Action: Please contact tech support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LSPV-7-MSG_GENERAL ### Response: (Severity: 7), (Category: ROUTING), (Description: System failed during an API call to database or event manager in the initialization phase of LSPV_SERVER process or its debugging subsystem. The text of the message displays the failed operation with error code.), (Recommended Action: The database or event manager may be experiencing higher than expected load. Attempt to re-start the LSPV_SERVER process after a few minutes.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_SYSDB_SET ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_FADB-4-SHM_MMAP_FAIL ### Response: (Severity: 4), (Category: FABRIC), (Description: FSDB FADB encountered an error while attempting to map the FADB shared memory), (Recommended Action: Search the event logs for events/errors related to the failure reason. Shared Memory Management is part of overall system. If there are failures here then other processes may also exhibit similar problems. Collect all the event logs (show logging) and the output of the following command. 'admin show process fsdb_fadb location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CSCMIB-3-CSC_BAG ### Response: (Severity: 3), (Category: SNMP), (Description: This may be due to invalid data being sent by the agent or request, or due to an error in the data-marshalling infrastructure. The current request cannot be completed. Check the request and try again.), (Recommended Action: Check the request and retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-HW_DETECTED_ERROR_PCI_SN ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cpuctrl driver HW error interrupt handler was invoked and found valid PCI SN error registers.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_MPLS-3-ERR_INFO_HEX ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code (in hex). Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.), (Recommended Action: Please collect the console log and the CLI output. show cef show cef location <> show cef trace location <> show cef platform trace all location <> show tech cef show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBIMGR-3-FAILED_TO_COMPARE_MD5 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Finding out if the local MBI in dSC and the boot requestMBI MD5 values matches or not got failed. Either the MD5 values are invalid, or the infrastructure is behaving incorrectly. The MBI operation in progress may not be carried out. %s - indicates the node on which the error occurred. %s - gives the MBI path we're comparing. %s - gives the MBI path we're comparing against. %s - gives the error message. %s - gives the MBI path we're comparing.), (Recommended Action: If the MBI operation does not complete successfully, then further manual action will be required. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIGCLI-3-EVH_INIT_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: Config process is failing to create an event manager. See error for reason.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-6-OVS_INFO ### Response: (Severity: 6), (Category: L2), (Description: OVS info message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_PAIRING-6-NOT_SUPPORTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: Because CRS-DRP is not supported in CRS Series 4 Slots Line Card system, therefore, drp pairing configuration will be disabled also.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_CFG-4-READ_FAIL_RECOVERY ### Response: (Severity: 4), (Category: FABRIC), (Description: If the confd read fails this reovery is triggered. Router is not reloaded, there will not be any effect.), (Recommended Action: In order to recover the setup from hw profile config mismatch, SDR reload is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CISCOSYSTEMMIB-7-CREATE_EVM ### Response: (Severity: 7), (Category: SNMP), (Description: Attempt to create an event manager fails for some reason.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-RSI_C_REGISTRATION_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to register for notification of changes to a VRF.), (Recommended Action: This failure may be due to lack of resources. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCT_MA-3-PREPAID_REQUEST ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: There is an internal failure when starting a new prepaid session or requesting a new quota. This can be seen when acct_ma sends a request to subscriber manager (iedged) process to initiate a prepaid event to AAA.), (Recommended Action: Check all applicable configurations on the router. Check if prepaid server is reachable and have correct configurations. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-6-NODAL_SERVICE_STATE_CHANGE ### Response: (Severity: 6), (Category: OS), (Description: Service state changed to available/unavailable.), (Recommended Action: Collect system logs and show tech ssm. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-NODE_KDUMP ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node's kernel is dumped to local harddisk or RP's harddisk.), (Recommended Action: Collect the crashinfo, core and pcds files created on harddisk before contacting Cisco for technical support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-7-MGMT_STATE ### Response: (Severity: 7), (Category: MGBL), (Description: The TTY server tried to update the TTY's state in SysDB and failed to do so.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the lsp-password command in IS-IS? ### Response: The lsp-password command is used to configure a password for IS-IS LSP packets. When configured, IS-IS will insert the password into the LSP packets it generates, and will check the password in received LSP packets. This provides a form of authentication to prevent unauthorized routers from injecting false routing information into the network. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-4-RESOURCE_LEAK ### Response: (Severity: 4), (Category: L2), (Description: BFD was not able to free certain resources, such as allocated memory, discriminator or checkpoint object, due to infrastructure API returning error from free/deletion operation(s). BFD should be able to continue processing by allocating new resources. However, support personel should be contacted to investigate the cause of resource leak.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_REPLICATE ### Response: (Severity: 4), (Category: L2), (Description: When attempting to replicate the bundle to one or more new interface locations, the replication operation failed. This probably happened because some hardware resource on the specified LC(s) was exhausted. The record of the new member(s) which triggered this replication will be removed from the bundle process on the RP but will still be referenced by the bundle process on the LC.), (Recommended Action: Determine whether the hardware resources for the LC(s) have been oversubscribed, e.g. more VLANs on the LC(s) and on the bundle that the LC(s) can support. If this is the case, reduce the number of allocated VLANs. Then remove the member configuration and reapply.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-THREAD_POOL_START ### Response: (Severity: 3), (Category: OS), (Description: An error occured whilst PlaceD was starting a threadpool.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-RIGHTARG ### Response: (Severity: 3), (Category: MGBL), (Description: 'The test token has invalid right argument'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-frag_flags_not_supported ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This message will typically occur when an ACE is specified with a fragment-flag of an attached ACL on egress direction or ACL is not in compressed mode.), (Recommended Action: Make sure that the ACL is attached with compression level 3.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-3-EVM_CREATE ### Response: (Severity: 3), (Category: OS), (Description: QNET process tried to create a thread for handling events but encountered error. The process will exit and retry again), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-6-NODE_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Useful general info logged by the Platform Fault Manager that can used to establish a sequence of events that occurred in the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-UNKNOWN_ACL ### Response: (Severity: 4), (Category: ROUTING), (Description: BGP received an unknown action (permit/deny/etc) from the ACL library), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-SI5345_ACCESS_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: SI5345 read/write access failure/success), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-ERR_ASIC_SYSLOG ### Response: (Severity: 3), (Category: FABRIC), (Description: This message is logged whenever an ASIC detects an error. This message includes:\ ASIC identifier, interrupt name & its ID, \ Interrupt type, effect of the error on the system & the software action taken.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_EVC_GET_FD ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: PPPoE MA failed to retrieve the file descriptor associated with the specified service. This is an internal error.), (Recommended Action: Consider restarting the PPPoE MA process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MXPDRVR-3-NCS1K_PROV_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Provisioning of specified slice has failed), (Recommended Action: The casue for the provisioning failure has to be analyzed. Collect the show tech logs by running 'show tech-support ncs1k detail' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-1-ERR_HW_RESET_PLL_THRESHOLD ### Response: (Severity: 1), (Category: L2), (Description: A hardware error is detected on the PLIM. Software will take action as described in the error message, if not none, to try to recover from the error. The hardware error and the software recovery action will not impact traffic. Device: %s%s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Software action: %s - the action that software will take to try to recover from the error. Recommended user action: %s - recommended action to the user. Possible values: 'none' 'replace XFP' 'PLEASE MANUAULLY RELOAD THE LC AT NEXT MAINTENANCE WINDOW'), (Recommended Action: Take the recommended user action as it is described in the error message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MGID_OOR-4-MGID_COUNT_OOR_GREEN ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-2-CLKCTRL_TX_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Interrupt controller FPGA reported that data it received from Timing and CPI controller FPGA had parity error), (Recommended Action: Please correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-7-CS_REL_MISMATCH ### Response: (Severity: 7), (Category: PLATFORM), (Description: Release mismatch), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check the card is a Cisco approved device if it is externally accessible. Capture 'show filesystem ' together with console log.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-6-LOCAL_EXEC_ACCT ### Response: (Severity: 6), (Category: SECURITY), (Description: MGBL session login logout syslogs when local cmd acct and exec acct is enabled), (Recommended Action: Added as part of new feature to account MGBL sessions) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to monitor RSVP TE tunnels? ### Response: To monitor RSVP TE tunnels, use the 'show mpls traffic-eng tunnels' command in EXEC mode. RP/0/RSP0/CPU0:router#show mpls traffic-eng tunnels <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EPM_SWITCH_CLIENT-3-GEN_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates an error condition in client library api while communicating with EPM SWITCH server process. It may be caused due to invalid api arguments by client processi, or a transient condition while the server process is respawning from crash, or the EP SWITCH hardware does not respond to inquery.), (Recommended Action: This message may indicate a transient condition while the EPM SWITCH process is booting up. Please check if the error message is seen continuously even after the EPM SWITCH process reached Run state. please contact tech-support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB encountered an error while attempting to create an event manager. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-SCHED_GET_PRIORITY_MAX ### Response: (Severity: 7), (Category: HA), (Description: The sched_get_priority_max() function returned an error which is indicated in the message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAL_IPHC-2-EA_INIT_FAILURE ### Response: (Severity: 2), (Category: L2), (Description: IPHC pal ea critical error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TUNNEL-3-NO_INTERFACE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A request to delete a non-existent interface has been received. This is relatively a harmless error, unless it is too frequent, in which case the reason for the error must be investigated, starting with the name of the interface printed in the error message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CALVADOS_DUMPER-6-TH_CREATE_FAIL ### Response: (Severity: 6), (Category: INFRA), (Description: Could not create thread to start copy of file), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information. Collect this error message, along with the output of 'show tech-support ctrace'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ct_agent-3-ERR_RC_HEX ### Response: (Severity: 3), (Category: SECURITY), (Description: Error description, hex_code of rc.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_MGR-3-EVENT ### Response: (Severity: 3), (Category: SERVICES), (Description: An error (other than EINTR) occured in the event loop. The process must exit.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_RX_SDFEC_OOF ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-DATA_NB_SERDES_1_FAIL_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: Data north bound serdes link 1 failure on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROLLER_ODU-3-INIT_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A failure occurred initializing a necessary module of the ODU Contoller. The process is unable to run. Restarting the process by retrying the operation may clear the issue or indicate that the system is in a unstable state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIP-3-ERR_REDIST ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error encountered during redistribution of other protocols into RIP.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the zoning feature in Cisco IOS XR and how is it configured? ### Response: The zoning feature allows grouping physical interfaces into security zones and defining security policies for traffic moving between zones. Interfaces in the same zone can communicate freely, while traffic between zones is subjected to policy restrictions. Zones are configured using the 'zone security' command and policies are defined using the 'zone-pair security' command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WD_MEMMON-1-MEM_ALERT ### Response: (Severity: 1), (Category: INFRA), (Description: Memory usage is above critical threshold, state is CRITICAL.), (Recommended Action: Please check top five memory consumers and kill some of the memory consumers.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-3-FAIL_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The DRP redundancy driver process exited for the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered inorder to recover. Execute 'show process reddrv location <>' to verify that the process is up and running after the restart. If it is still non-operational, try doing from the admin mode 'process restart reddrv location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ERRDIS-4-EVM_CLEANUP_FAILED ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The Verification Daemon failed to destroy its event manager. The process is exiting anyway which should clear the condition.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAMSG-3-DEBUG_INIT_FAILED ### Response: (Severity: 3), (Category: L2), (Description: SPA related error msg comes when there is some problem with the initializing the debug event type structure), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_MQ_SEQ_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue sequence error on XAUI 0 MQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSEC-3-ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: IPSec Base component Fatal Error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-MIB_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred while initializing the BGP MIB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-QDR_DATABIT_STUCK_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: QDR memory databit stuck on bridge instance-2.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_APS-6-ADDR_THRESHOLD_XCED ### Response: (Severity: 6), (Category: IP), (Description: The Address configured are too many. The message is to confirm if this is intentional.), (Recommended Action: Check the configuration to confirm the configuration is intentional. Remove any misconfiguration. If that does not work contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMA-3-LINK_GROUP_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: The link addition/removal from a IMA Group has failed due to a software error.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_OC48-6-OPTICS_REMOVAL ### Response: (Severity: 6), (Category: L2), (Description: Optics module has removed %d - bay number %d - port number), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-4-RETRYDB_NONEMPTY ### Response: (Severity: 4), (Category: ROUTING), (Description: FIB has detected that some objects are in the unresolved state. As a result, traffic may end up being dropped for an extended period of time.), (Recommended Action: Take a look at 'show cef retry-db location ' and 'show cef unresolved location ' for the node and protocol for which the syslog is being shown. If there is nothing in the databases, please ignore the error message. Check that traffic being forwarded via the next hop shown in the output of 'show cef unresolved location ' is being forwarded correctly. If it is, then no further action is necessary.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-QSM_ADD_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cctl_primary_server process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show cctl_primary_server location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-PARTNER_CHURN ### Response: (Severity: 5), (Category: L2), (Description: Partner churn has either been detected (due to the failure of the partner to be marked as synchronized on this link soon enough) or has now cleared. If the link is in Standby state on the peer router, then partner churn will be detected after the churn timeout; this is expected behavior. Otherwise, this indicates a possible misconfiguration.), (Recommended Action: If partner churn has been declared and the link is not marked as Standby on the peer router, check that the configuration for the link allows it to aggregate, and fix as appropriate. Check for misconfigurations between the two ends of the link which is reporting churn. The output of the show bundle command may help identify the problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What happens when you insert or remove a node in IOS XR? ### Response: When you insert a new node in IOS XR, the system automatically applies the current running configuration to the new node. When you remove a node, the configuration specific to that node is automatically removed from the running configuration. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XBAR_ERR-3-ERR_CARDTYPE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Crossbar driver encountered an Error. The cardtype of the nodeid is not correct .), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-MSGERROR_FAILED ### Response: (Severity: 7), (Category: OS), (Description: Could not reply to client. This will impact behavior of dumper.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFO_EA-6-PD_ERROR_UL_INTF_REMOVAL ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: During the handling of a bundle member update notification, the platform returned an error which cannot be handled. The interface may continue trying to send traffic over an interface which it should no longer be using, resulting in traffic drops.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_7_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature less than or equal to the low temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CPAK with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the package manager process in IOS XR installation? ### Response: The package manager process is responsible for managing the installation and removal of software packages on the router. It works closely with the instdir process during installation operations. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the BGP local preference attribute? ### Response: The local preference attribute is used to prefer certain paths external to an AS. A path with a higher local preference is preferred. It is the second criteria in the BGP best path selection after weight. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB_QUERY_ORA-3-INSTBUILD ### Response: (Severity: 3), (Category: ROUTING), (Description: There was an internal software error in the routing policy library and as a result routing policy may not be applied correctly.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-AUTO_ABORT_TIMER_RUNNING_WARN ### Response: (Severity: 4), (Category: INSTALL), (Description: The auto-abort timer is running and soon to expire.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISKUTIL-4-INIT_WARNING ### Response: (Severity: 4), (Category: MEDIA), (Description: An unexpected initialization problem condition encountered. It will not affect system backup but may lose some debug information.), (Recommended Action: Collect system log information. Let router continue to run if only this warning shows up No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR_LIB-4-PARAMETER_NULL ### Response: (Severity: 4), (Category: INSTALL), (Description: An NULL parameter has been unexpectedly passed to the Install infrastructure.), (Recommended Action: This is an internal software error and will be recovered automatically. Please retry the operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-4-CARD_PWR_OPER_FAILED ### Response: (Severity: 4), (Category: DRIVER), (Description: Card manager has failed to process power-on request from shelf_mgr as the previous request is in progress. Once the previous request is done it will take the new request), (Recommended Action: Run 'hw-module location reload' command to power-on the card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAW_LIB-4-REBOOT_INFO ### Response: (Severity: 4), (Category: MEDIA), (Description: printing the reboot reason.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_ALARM-2-DEVICE_HALT ### Response: (Severity: 2), (Category: FABRIC), (Description: INGRESSQ, ASIC got halted. The halted block and its parent block are provided), (Recommended Action: Open a case with TAC Support along with this required information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-NONEXISTENT_INTF ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The Linux interface specified in XR_INTERFACES does not exist.), (Recommended Action: Check the Linux interface names in the XR_INTERFACES environment variable.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-3-IPMC_FEC_EXISTS ### Response: (Severity: 3), (Category: PLATFORM), (Description: IPMC fec exists), (Recommended Action: Please collect below CLI outputs, (show logging), (show dpa trace loc <>), (show dpa objects all location ?), (show mfib hardware trace all location ?), (show dpa objects ipmcroute location ?), (show controller fia trace all reverse location ?), (show controllers fia trace brcm-error reverse location ?), (show controller fia trace brcm-sdk reverse location ?) Report to your technical support representative for further details.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNVGEN-3-LWM_API_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: Failure in LWM client API.), (Recommended Action: Collect the following logs and contact your technical support representative for assistance. a) Console messages b) show tech-support parser) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-2-CPU_PRT_A_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Interrupt controller driver detected an address parity error from the cpu), (Recommended Action: Please try to correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_SYSDB_REG_VERIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed to register for verification of changes to its configuration data.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The IS-IS process must be restarted before it can function correctly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-7-SYSMGR_REGISTER ### Response: (Severity: 7), (Category: IP), (Description: Registering with sysmgr failed while getting tty details. Internal error.), (Recommended Action: Internal error. Process will retry the operation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-MBIST_TIMER_EXPIRED ### Response: (Severity: 3), (Category: FABRIC), (Description: MBIST timer expired. Board will reload to resume normal operations.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_2_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_2 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_SSE-3-ERR_SYSDB_BIND ### Response: (Severity: 3), (Category: L2), (Description: BFD Agent failed to open a connection to the SysDB Server process for one of the paths. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective MSC reboot.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-4-ANR_SIGN_VERIFY_FAIL ### Response: (Severity: 4), (Category: SERVICES), (Description: 'The new device joining the network verified the ' 'signature of autonomic registrar as a part of mutual authentication ' 'and the verification failed'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPT_SUB-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an infomative message in DPT), (Recommended Action: Please collect the console log, DPT traces (show dpt trace loc <>), Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_HAL-3-ERR_INFO_NOT_SUP ### Response: (Severity: 3), (Category: PLATFORM), (Description: This error in PLATFORM FIB HAL indicate that the logged feature not supported), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show logging, show version, show platform, show install active, show cef platform trace all all loc <>). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-3-PCL_XCELL_ERR ### Response: (Severity: 3), (Category: FABRIC), (Description: Sponge encountered a PCL extra cell error, and received more cells for a packet than were expected.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-LTRACE_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AUTH_SRV-3-ERR_2_PARAM ### Response: (Severity: 3), (Category: SECURITY), (Description: auth srv exp error message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SDS_LIB-4-INIT ### Response: (Severity: 4), (Category: INSTALL), (Description: An error occurred during initialization of the library.), (Recommended Action: Sysmgr will automatically re-attempt initialization of SDS. No user action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS_MODULE-2-DEV_OPTICS_PORT_UNSUP ### Response: (Severity: 2), (Category: PLATFORM), (Description: An optics Module not supported for the port error was detected during module initialization. A optics module not supported for the port error is reported when Optics is not supported on the port. The optics is the pluggable optics on the line cards. Optics initialization may happen when linecard boots up, optics OIR and line card process restart.), (Recommended Action: Verify that the optics Module is supported for the port. Replace the optics with a working one (if any) to isolate bad optics. Check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the command 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_NPMB-3-BAD_LISTENER_TAG ### Response: (Severity: 3), (Category: OS), (Description: Unknown lpts packet type; or LPTS packet with bad listener tag.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_NOTIF_Q_FULL ### Response: (Severity: 3), (Category: OS), (Description: Too many notifications have been sent to the component. The queue to hold the notification has overflowed.), (Recommended Action: When this issue happens, it will trigger an automatic restart. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-DUMP_REQUEST ### Response: (Severity: 7), (Category: OS), (Description: The information message for debug use.), (Recommended Action: Displayed when a process is crashed. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-6-PORT_STATE_CHANGE_ADMIN_UP ### Response: (Severity: 6), (Category: INFRA), (Description: Informational message indicating that the admin state of the specified port has changed to up.), (Recommended Action: This is an informational message and does not necessarily indicate a problem. This message is expected when the port's admin state is changed via CLI.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-AUTO_ABORT_TIMER_EXPIRING ### Response: (Severity: 2), (Category: INSTALL), (Description: The auto-abort timer is about to expire.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FMGR-3-SUB_ID_MSG_TOO_LARGE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A message from Platform Manager containing set/unset notifications for sub-interface VLAN IDs was too large and had to be dropped because enough memory could not be allocated. As a result, for a 'set' notification, QoS was not enabled for the reported VLANs. For an unset notification, QoS was not disabled for the reported VLANs.), (Recommended Action: Restart feature_mgr process. Example: In exec mode, 'process restart feature_mgr location 0/1/CPU0' This will cause all notifications to be delivered to Feature Manager again. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TYPE6-3-DEBUG_INIT_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: The process could not start the debug event. Hence the debug event could not be created.), (Recommended Action: For further detail contact the Cisco technical support representative with the gathered information and the exact error message as it appears.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CANB_SERVER-6-CBC_REFRESH_PWR_SEQ ### Response: (Severity: 6), (Category: PLATFORM), (Description: CBC has detected there there is a CRC check failure in the power sequencers on this card and attempting to reprogram the sequencers in error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cds_proxy-3-PROC_AVAILABLE ### Response: (Severity: 3), (Category: OS), (Description: System manager process is not available.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPU_CTRL-3-TIMEOUT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The system has encountered an error while refreshing SFP port.), (Recommended Action: Replace with a Cisco supported SFP If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WD_SYSMON-3-PROC_CNT_MINOR ### Response: (Severity: 3), (Category: INFRA), (Description: When number of processes/threads has crossed above MINOR Threshold Percentage.), (Recommended Action: The number of processes/threads running has increased. Determine if there are any unnecessary processes/thread available in dir '/var/log/debug_proc_cnt' and kill them by using kill -9 .) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-6-INFO_OUTR_VLAN_SES_THRSHLD_NO_EX ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions for a particular Outer VLAN on the given access interface is no longer exceeding the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDT-2-PLUGIN_START_FAILED ### Response: (Severity: 2), (Category: MGBL), (Description: Model driven telemetry data plugin thread start has failed.), (Recommended Action: Restart the process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBAPI-3-EVM_CREATE_ERR ### Response: (Severity: 3), (Category: SNMP), (Description: An internal operation failed. The system will attempt to recover.), (Recommended Action: Copy the message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_IPV6_EA-3-ERR_INIT_STR ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Typically, this is an error where the software fails during initialization. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize software. This condition indicates a problem with the software on the card where the error is seen. Typically, this occurs when the software tries to initialize invalid objects. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid during initialization. - Failed to program forwarding features. This condition indicates a problem where the software fails to program forwarding features to the hardware during initialization/ configuration.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show cef ipv6 location <> show cef ipv6 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-FATAL_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected a fatal error.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: d1qnetio-3-REGISTRY_CREATION_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The 802.1Q NetIO component could not necessary data structures during its initialization. Software forwarding VLAN functionality on the affected is likely not to work.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-6-HOLDDOWN_TIME_START ### Response: (Severity: 6), (Category: SECURITY), (Description: TACACS+ server is unreachable or down. Server in holddown.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG_HIST_UPDATE-3-TUPLE_UNPACK ### Response: (Severity: 3), (Category: MGBL), (Description: Internal error), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-0-ECC_ERROR ### Response: (Severity: 0), (Category: PLATFORM), (Description: Unrecoverable ECC), (Recommended Action: Gather the data listed in 'required_info'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-ROUTE_TYPE_NONE ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered when computing the route type.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospf - show ospf trace all - show route ipv4 detail - show ospf routes detail) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_SVR-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID Server was unable to allocate memory. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to enable RSVP graceful restart? ### Response: To enable RSVP graceful restart, use the 'rsvp graceful-restart' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#rsvp graceful-restart <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_NETIO-3-PARSE_FAILURE ### Response: (Severity: 3), (Category: L2), (Description: The file atm_netio.rules has been modified and parsing fails), (Recommended Action: Check why the rules file has been modified. The specified line number will give a clue for failed parsing.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between installing a package using the install add command versus the install activate command? ### Response: The 'install add' command copies the package to the router's storage but does not make it active. The 'install activate' command is used to make the package active on the router. Packages can be added and activated in a single step using 'install add' followed by 'install activate' in a single command line. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBQSMGR-1-DBG_SCRIPT_REGISTRATION_FAILED ### Response: (Severity: 1), (Category: INSTALL), (Description: The communications channel to QSU Manager is unavailable.), (Recommended Action: The process is automatically restarted, which should lead the process to recover its state, and attempt to register the same again. If this process is involved in protocol operation, then there may have been packet loss as a result of this event which requires remedial action. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-FILE_IO ### Response: (Severity: 3), (Category: MGBL), (Description: Unable to read/write the file), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-MISS_EOP_0_FIADDR_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Missing EOP-0 from FIA DDR on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAQFPBridgeCtrl-1-ERP_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: SPA Bridge ASIC detected an ERP timeout, parity, or protocol error.), (Recommended Action: Restart the Jacket Process. If the problem persists, reboot the card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GT_ETH_MGMT-3-NETIO_INIT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error detected when initializing the netio. process will restart automatically to recover from this error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-5-EAP_ATTESTATION_SUCCESS ### Response: (Severity: 5), (Category: L2), (Description: Successfully verified the stamped passport provided by peer), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-3-SPA_PIO_ERROR ### Response: (Severity: 3), (Category: L2), (Description: This is an error message indicating a Hardware access error for a SPA. If this is a recurrent message, it usually is due to faulty hardware, loose connection at the SPA connector on the jacket card. Try reseating the SPA and see if the issue is resolved. If not, please check with TAC.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-6-SESSION_USAGE_BELOW_THRESH ### Response: (Severity: 6), (Category: PLATFORM), (Description: Sessions active have fallen below 90% threshold for this Details will be given in the meesage displayed), (Recommended Action: None. System should be in stable state and all Translation should go through fine) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYNCFS2-3-INIT_FAILED ### Response: (Severity: 3), (Category: MEDIA), (Description: Syncfs failed to initialize a module.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-4-INVALID_PLIM ### Response: (Severity: 4), (Category: PLATFORM), (Description: This msg indicates that a PLIM type in the given slot does not match the card type; or the card/plim is not appropriate for the chassis.), (Recommended Action: Replace the BOARD/PLIM with the correct type.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_PROCE_NODEID ### Response: (Severity: 3), (Category: OS), (Description: proc nodeid error.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-7-GENERIC_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: A generic error occurred in Services PLIM driver. Cause of the error will be mentioned in the message displayed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How do you activate a software package in Cisco IOS XR? ### Response: A software package is activated in Cisco IOS XR using the 'install activate' command, which enables the package's features on the router. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INVMGR-6-NODE_STATE_CHANGE ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates the node state (eg. IOS XR RUN, MBI_RUNNING). A node being a card, SPA, etc. %s - indicates the node/location in // format %s - indicates the state), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CISCOSYSTEMMIB-3-TARGET_CFG_PROBLEM ### Response: (Severity: 3), (Category: SNMP), (Description: error occured during config manager operation.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_EDM-3-NOMEM ### Response: (Severity: 3), (Category: L2), (Description: The system is low on memory and not enough was available to complete the request), (Recommended Action: Check the box for processes with excessive memory If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ERRDIS-3-AUTO_RECOVERY_RETRY_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Auto-recovery failed to restart on the given interface. This interface will remain in Error-Disable state until manually cleared.), (Recommended Action: Manually clear Error-Disable state on the given interface if desired, else reconfigure an Auto-Recovery period to retry. Based on the failure reason, the user may wish to reduce memory consumption or investigate other system-wide issues. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp graceful-restart restart-time' command in IOS XR BGP configuration? ### Response: The 'bgp graceful-restart restart-time' command is used to configure the maximum time that a BGP speaker will wait for a restarting peer to come back up. It is part of the BGP Graceful Restart configuration. The default restart time is 120 seconds. If the restarting peer does not come back within this time, the BGP session is torn down. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-5-ASIC_ERROR_RESET_THRESH_CROSS_NOTIFICATION ### Response: (Severity: 5), (Category: PLATFORM), (Description: Multiple reset occurred, threshold exceeds, notification is sent to driver for proper action), (Recommended Action: Due to too many reset, the driver may reload the board or slice to recover. *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-3-HOST_LINE_LOA ### Response: (Severity: 3), (Category: PLATFORM), (Description: Loss of Alignment between the NPU and DSP), (Recommended Action: Contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-PORT_NUM_EXHAUST ### Response: (Severity: 4), (Category: L2), (Description: PTP was unable to allocate a port number to an interface, as all available port numbers are currently allocated.), (Recommended Action: Remove PTP configuration from one or more interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COREHELPER-3-NOTHING_READ ### Response: (Severity: 3), (Category: OS), (Description: Read of inotify file descriptor failed with specified message.), (Recommended Action: Check dumper process, show context, collect console message. Report this message to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-3-ERR_MEM_MAP ### Response: (Severity: 3), (Category: FABRIC), (Description: The FIA driver was unable to map the hardware of the specified ASIC instance into its memory space and therefore failed to initialize. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: exec-3-LOGIN_AUTHEN ### Response: (Severity: 3), (Category: MGBL), (Description: login() failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-ISM_PD_LIB_SPA_UNSHUTDOWN ### Response: (Severity: 6), (Category: INSTALL), (Description: The shutdown operation is being performed on the indicated SPA when fabric plane upgrade fail.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_LASER_EOL ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HSRPMIB-4-WARN_DEBUG ### Response: (Severity: 4), (Category: SNMP), (Description: During initialisation of the HSRP MIB, it was not possible to register to be notified of changes to the debugging state. The MIB will continue to function, but it will not be possible to turn on debugging for the MIB.), (Recommended Action: If debugging is essential, then restart SNMP. This will reinitialize the HSRP MIB. If the problem persists, do the following. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_1_LOW_TEMP_ALARM ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser temperature less than or equal to the low temperature alarm threshold. The QSFP+ is the pluggable optics on the line cards. The temperature threshold values are read from the QSFP+.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the QSFP+ with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-6-MODE_FAILURE ### Response: (Severity: 6), (Category: SECURITY), (Description: Negotiation with the remote peer failed.), (Recommended Action: 'If this situation persists contact the remote peer') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-2-PARENT_REREGISTER ### Response: (Severity: 2), (Category: ROUTING), (Description: A RIB download client (typically bcdl_agent), reregistered from a table while it still has children referring to this table. The number of routes may no longer be insync in all FIBs. If corresponding bcdl_agent restarted just before this message was seen, this error message can be ignored.), (Recommended Action: Restart the corresponding bcdl_agent process. *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLDP-5-BRANCH_MODIFY ### Response: (Severity: 5), (Category: ROUTING), (Description: A mLDP branch has been modified.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-7-EVENT_BLOCK ### Response: (Severity: 7), (Category: OS), (Description: An error occured while PlaceD was waiting for a messages, PlaceD ignored the error and continued to wait for more messages.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM_CLIB-3-MSG_GENERIC_FUNC ### Response: (Severity: 3), (Category: IP), (Description: A call to some system function to initialize bcdls failed. ip arm consumer initialization api would return error back to the client.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-ACP_CHANNEL_TO_NBR_CREATED ### Response: (Severity: 6), (Category: SERVICES), (Description: 'Autonomic Network Control plane Channel has been ' 'created to the neighbor'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-3-SERVER_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB server could not initialize due to above error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-VPWS_SINGLE_HOMED_PATHS ### Response: (Severity: 3), (Category: L2), (Description: More than one EAD/EVI route was received for a single-homed (zero ESI) VPWS.), (Recommended Action: Perform network level review, and ensure the correct AC IDs are being used.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTS3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-6-DISK_STATUS ### Response: (Severity: 6), (Category: MEDIASVR), (Description: This ios_msg is raised when an ECU Disk is inserted or removed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_11_LOW_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CFP with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: libpcmcia_linux-7-FD_UNAVAILABLE ### Response: (Severity: 7), (Category: PLATFORM), (Description: pcmciad will spawn filesystem process and cardmgrd without standard output. This would result in no debug messages from those processes.), (Recommended Action: Please contact TAC if this happens continuously.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you configure health checks in Cisco IOS XR? ### Response: To configure health checks in Cisco IOS XR, use the 'health-check' command followed by the test type (such as system, process, or datapath) and the test parameters such as the interval and threshold values. You can also configure actions to be taken when a health check fails, such as logging a message or restarting a process. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-SHOW_NOMEM ### Response: (Severity: 4), (Category: ROUTING), (Description: The requested display output may be incomplete due to an internal memory allocation problem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-VRF_INVALID_LS_LAYER ### Response: (Severity: 3), (Category: L2), (Description: Unable to assign VRF because logical switch is not layer3 type.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKWATCH-3-DEPLETION_CRITICAL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The depletion level of the specified packet resource is critical. At this level of depletion, routing protocols on the impacted node are not able to allocate packets and the software packet path will be impacted. Critical services on the node may not be able to allocate packets and thus could be impacted.), (Recommended Action: Customer should monitor depletion levels using 'show packet-memory' commands. If packet memory remains depleted for significant period of time then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-ENV_STATIC_DATA_ERROR ### Response: (Severity: 3), (Category: OS), (Description: An environment record data processing error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS traffic engineering autoroute feature? ### Response: The MPLS traffic engineering autoroute feature allows IGP routes to be automatically routed over MPLS TE tunnels. This provides IGP shortcuts using the TE tunnels. Autoroute can be announced globally for all tunnels or on a per-tunnel basis. It is enabled with the tunnel mpls traffic-eng autoroute announce command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_EA-3-INIT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: An initialization failure occurred in FIB EA layer. The message string indicates the reason for the failure. Here is a list of possible reasons for this message (not all-inclusive). - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects.), (Recommended Action: Please collect the console log and the CLI output. show logging show running-config show cli history detail loc <> show tech-support location <> show version show install summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_INFRA_LIB-3-failed_to_validate_mutex ### Response: (Severity: 3), (Category: PLATFORM), (Description: Unable to validate mutex.), (Recommended Action: Please contact tech support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_V6FIB_RP-6-VPNV6_CONTEXT_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The message is for recording VPNv6 global context intialization event. No action is required.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-1-TX_MACRO_SPEED_MISMATCH ### Response: (Severity: 1), (Category: FABRIC), (Description: Unexpected macro type value read from ASIC. There could be a h/w or FPGA issue.), (Recommended Action: Collect all the event logs and 'sh controller fabric trace driver all location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-EVPN_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: EVPN callback returned error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-HSSDFAIL ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: An automatic register for one of the HSSDs failed.), (Recommended Action: If any of these messages occur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-6-EDM_BAG_REGISTRATION_FAILED ### Response: (Severity: 6), (Category: OS), (Description: The process failed while attempting to register its external data manager data blocks with SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RUNTIME-7-SVC_DEBUG ### Response: (Severity: 7), (Category: OS), (Description: A service API debug is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-3-ERR_INIT ### Response: (Severity: 3), (Category: L2), (Description: An error was encountered whilst initializing the SSRP sybsystem: %s.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the PPP MA process. *SUPPORT*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_VLAN_EA-3-MAX_VRRP ### Response: (Severity: 3), (Category: PLATFORM), (Description: Configuration failed because the maximum number of VRIDs which can be programmed has exceeded.), (Recommended Action: Please capture the complete error log. Please check the data sheet for the supported configuration. Please contact TAC for any support on this) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_PROXY-7-SYSTEM_ERROR ### Response: (Severity: 7), (Category: HA), (Description: A call to a system function failed with the specified error code.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_SERDES-3-MUTEX_OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime failure occurred in Serdes layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code. The process can continue functioning as expected despite the failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OPTICS-2-PORT_SPEED_MISMATCH ### Response: (Severity: 2), (Category: L2), (Description: The optic interface module was inserted on the port which does not support the speed of the optics which was inserted. The interface type would remain to the default type or the type which was present before the port was empty. in a link down.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-4-DEVICE_DEACTIVATED ### Response: (Severity: 4), (Category: OS), (Description: The device on the node is deactivated for onboard logging.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_11_HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6-6-EDM_ENCODE_FAILED ### Response: (Severity: 6), (Category: IP), (Description: A process has requested information from ipv6_io through SysDB, probably as a result of executing a show command. The data requested could not be encoded.), (Recommended Action: Restarting sysdb process may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-2-ASIC_ERROR_CIH_INIT_THRESHOLD_CARD_SHUTDOWN_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Uncorrectable asic errors occured on card and board could not be shut down), (Recommended Action: ASIC errors that are uncorrectable have occured and exceed the threshold. Card could not be shut down because of some errors. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPD-3-FETCH_ERR ### Response: (Severity: 3), (Category: IP), (Description: DPM interacts with AAA for getting identity of the session. This error occurs when DPM tries to get subscriber ifhandle), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_VKG-7-ERR_BAG_REGISTRY ### Response: (Severity: 7), (Category: ROUTING), (Description: The MFWD-ASR9K library encountered internal error during sysdb/edm init setup. The init setup will be retried for finite number of retries.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-NOMEM_RESET ### Response: (Severity: 3), (Category: ROUTING), (Description: The requested operation could not be accomplished because of a low memory condition. One or more neighbor sessions have been reset to free some memory.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XFP-2-LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected an XFP Tx power less than or equal to the low Tx power alarm threshold. The XFP is the pluggable optics on the line cards. The Tx power threshold values are read from the XFP.), (Recommended Action: Verify that the device is properly inserted. Replace the XFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show mpls interfaces' command in IOS XR? ### Response: The 'show mpls interfaces' command is used to display information about the interfaces that are enabled for MPLS. It shows whether MPLS is enabled, the MTU for labeled packets, the range of labels assigned to the interface (in case of per-interface label space), and the LDP neighbor on the interface. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-3-PROCAGENT_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB server failed procagent initialzation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-NOTIFY_AIS_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The CFM packet handling module has detected that an AIS signal has changed (started or expired), but has failed to notify the management module. As a result, the proper handling for this event (eg generating log messages) will not take place.), (Recommended Action: If the error persists, the problem may be corrected by restarting the cfmd process on the node where the problem is being reported.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-5-LDP_VRF_W_SVD ### Response: (Severity: 5), (Category: ROUTING), (Description: FIB has detected that LSD is sending labelled routes in a non-default VRF with SVD enabled on the card. This is currently not a supported feature and as such, LSD routes may be dropped on the card and may not be re-instated even after the non-default VRF becomes applicable on the card.), (Recommended Action: Please ensure SVD is disabled if LDP in a VRF is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIAAPI-4-INVALID_FSTYPE ### Response: (Severity: 4), (Category: MEDIA), (Description: File system type is not supported on the media device.), (Recommended Action: Format the device to a supported file system if the device is not a boot device Report to TAC if the message comes from a boot device) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-PKT_LEN_ERR_0_XAUI_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet length error - 0 from XAUI on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-2-SRSP_ACTIVE_EOBC_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Standby RSP has detected an error with the active eobc link between this standby RSP and one or more line card)(s)), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON_EA_VERIFY-6-POLICY_ERROR ### Response: (Severity: 6), (Category: PLATFORM), (Description: Peformance traffic service policy verification encountered the specified error), (Recommended Action: Correct the performance traffic service policy) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-VERSION_MISMATCH_RELOAD_OPERATION_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: The node needs to reload in order to recover from version mismatch in software. However the automatic install reload could not be initiated.), (Recommended Action: Check the shelf_mgr process to make sure it is up and running properly. Check the general state of the VM to see if anything may be causing reload not to happen for Install. Collecting show tech will help further investigation on the cause. Please manually reload the node using 'hw-module location reload' in order to complete the recovery or try manually reloading the node.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-INTERNALERR ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please provide output from the following commands: - show tech-support routing ospfv3 detail) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-FLASH_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in READ/WRITE to flash memory. Exact Cause of the error will be mentioned in the message displayed. This error will block Application image launch), (Recommended Action: Do cold reboot of Services PLIM MSC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the link-state advertisement (LSA) in OSPF? ### Response: Link-state advertisements (LSAs) are the packets used by OSPF to exchange topology information between routers. Each LSA contains information about the state and cost of the router's links to its neighbors. LSAs are flooded throughout the area so that all routers can build a complete topology map. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND_LITE-3-SELF_GENERATE_FAIL ### Response: (Severity: 3), (Category: L3), (Description: The IPv6 Neighbour Discover (ND) spoofing process (ipv6nd_lite) has generated an internal diagnostic report normally emitted only during unit test. This is not expected during production use, but does not in itself indicate a condition that will prevent the router from working.), (Recommended Action: Check for any other error messages.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: 12IN1-3-ERROR ### Response: (Severity: 3), (Category: L2), (Description: A general failure occured while executing the function in question. The message contains info about the location and cause of the failure and possibly anticipated actions/effects.), (Recommended Action: Verify continued correct operation of the Serial 12in1 interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_RP-3-PARAM_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: During initialization of the Forwarding-Information-Base of the CRS platform, an unexpected parameter inconsistency has been detected. The running software should automatically recover if it isn't a hardware error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-QAD_Q_PRODUCE_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: EINT driver failed to populate qad netio egress queue), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BPE_CLIENT-3-ERR_CDI_BIND_RACK ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in i2c driver due to cdi bind function call failed in th particular rack.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FT-6-FAN_SPEED_THROTTLED ### Response: (Severity: 6), (Category: LIBRARY), (Description: Fantray fans need 2 fabric modules to provide enough power to run at 100 PWM. With just one fabric module, fan speed has to be throttled at lower speed), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN-6-BRIDGE_MTU_MISMATCH_CLEAR ### Response: (Severity: 6), (Category: L2), (Description: The interface MTU now matches the bridge payload MTU.), (Recommended Action: No particular action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-4-QFP_FAILURE_MEM_ALLOC ### Response: (Severity: 4), (Category: L2), (Description: The process failed to allocate memory for the specified resource), (Recommended Action: When errors occur in jacket, it is very likely the jacket process will restart itself This is a resource starvation condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-EAIDB ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates that an error has occurred in IP Tunnel Execution Agent IDB. IDB can't be found or created. Particular reason is included in this message.), (Recommended Action: Please restarting IP Tunnel Execution Agent with the command process restart ip_tunnel_ea location . If the problem persists, please contact Cisco TAC and provide this message text as well as the information specified in required_info section.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CGN-3-EVENTMGR_INITFAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of the CGN process on a particular node. The errors were seen during event manager operation. The process will be restarted.), (Recommended Action: Try restarting the CGN process showing this error. Please contact support if the issue does not get resolved after process restart.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ITAL_SHM-7-ERR_INIT ### Response: (Severity: 7), (Category: OS), (Description: Initialization of ITAL failed. The traceback can be used to get the function/line number of error generating code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-4-RPF_REDIRECT_THRESHOLD ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-MQ_SEND_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to send IPC message to IKE process. Most likely casue the process is too busy), (Recommended Action: 'contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. with the exact error message seen') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN-3-LIST_NODE_INCONSISTENCY ### Response: (Severity: 3), (Category: OS), (Description: SHMWIN encountered an error condition, list node check failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSHD-3-ERR_MSG_LEN ### Response: (Severity: 3), (Category: SECURITY), (Description: Message lenght is invalid), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-CLI_ACTION_IGNORED ### Response: (Severity: 5), (Category: ROUTING), (Description: The CLI action is ignored because the node is not active.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_DATATYPE ### Response: (Severity: 4), (Category: SYSDB), (Description: A datatype other than one of those supported was supplied.), (Recommended Action: Use help for a list of supported datatypes. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-PWR_SEQ_FAULT_LOG_SAVED ### Response: (Severity: 4), (Category: DRIVER), (Description: The fault log saved in power sequencer device has been collected and raw data has been decoded and saved in the indicated file.), (Recommended Action: The saved file can be collected as part of 'show tech-support ccc' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_ACL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS encountered the specified unexpected error whilst performing the specified operation on the specified access-list. As a result IS-IS's operation will not correctly reflect the contents of the ACL. This may be due to a low-memory condition but may also be due to internal programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the IS-IS process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE4_CODE_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE4_CODE_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBUS-3-HBM_LANE_REPAIR_CHANNEL_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates the channel error associated with the NP HBM memory lane repair operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLMGR_UI-3-CLI ### Response: (Severity: 3), (Category: APP_INFRA), (Description: An unexpected error occurred while parsing the policy manager configuration command.), (Recommended Action: If the action suggested in the error message does not help, try exiting and re-entering the config mode. If this doesn't help try restarting parser_server via cli 'process restart parser_server'. Contact TAC if the problem persist, with required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IPV4_EA-3-FAILURE1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is a failure message in the ASR9K platform specific code software to indicate anomolies that are not serious failure . This failure is most likely caused by a temporary situation, so is unlikely to re-occur.), (Recommended Action: Please collect console log, traces * SH_CMD show af-ea ipv4 trace errors loc * Also notice if the failure message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAT_CHASSIS_ENVMON-2-SAT_FAN_RPM_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: The FAN RPM of the satellite is currently running above/below the operating level.), (Recommended Action: The current FAN RPM values can be checked using the CLI: Copy the error message exactly as it appears on the console or in the system log. Issue the (admin)# show env command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin)# show env output, call your Cisco technical support representative and provide the representative with the gathered information. --> particularly for fan output of SAT ID. Copy the error message exactly as it appears on the console or in the system log. Issue the (admin)# show env trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the (admin)# show env trace output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-2-CPP_ASYNC_FIFO_SBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: IBS from CPP packet Async FIFO single bit error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FLOWTRAP-3-BAD_ACTOR_INTF_NOT_CLEARED ### Response: (Severity: 3), (Category: OS), (Description: The punt flow trap failed to completely clear the hardware settings for the 'penalty box' for the above specified interface which is using more hardware resources (i.e Bad Actor). Traffic from this source MAC may be affected. When a flow through any interface is trapped, it is tagged as a Bad Actor and will be added to 'penalty box', this box will restrict the traffic through that interface by applying penalty policing.), (Recommended Action: If traffic from the interface is affected, try flapping the interface or reloading the line card. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp graceful-restart restart-time' command in IOS XR BGP configuration? ### Response: The 'bgp graceful-restart restart-time' command is used to configure the maximum time that a BGP speaker will wait for a restarting peer to come back up. It is part of the BGP Graceful Restart configuration. The default restart time is 120 seconds. If the restarting peer does not come back within this time, the BGP session is torn down. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERR_INFO_OPER1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, operational error information), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>), 'show install active', 'show logging console', 'show platform' and 'show version'. Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-5-SATELLITE_CLEAR_ALARM ### Response: (Severity: 5), (Category: PKT_INFRA), (Description: The satellite has sent a notification that an alarm has been cleared.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-3-lsp_update_delegation_absent ### Response: (Severity: 3), (Category: OS), (Description: LSP is not delegated to this PCE), (Recommended Action: Send update from the PCE to which the LSP is delegated) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPIO_PD-3-NULL_INIT_DATA ### Response: (Severity: 3), (Category: PLATFORM), (Description: Protocol packet path initialization failed due to no protocol data from protocol module. Initialization is aborted and may be retried.), (Recommended Action: Restart the protocol process. 'process restart location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-PKGMGR_DB_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: An error has been encountered by yumdb. The install infra has attempted to rebuild the rpm database and retried the command, but an error was still hit.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. A system reload is recommended if this message is seen repeatedly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_HFR_LIB-2-SUPER_SPA_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: %s-Type of the critical error on SPA. %d- Return value for the above mentioned error. Unable to read hw_type for super spa.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-0-CD_IN_RESET_STATE ### Response: (Severity: 0), (Category: PLATFORM), (Description: This message indicates that this node was parked in the in-reset state due to the reason specified.), (Recommended Action: Use hw-module loc reload command to release card from IN-RESET state.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-4-DB_ATTACH ### Response: (Severity: 4), (Category: L2), (Description: The specified process failed to connect to PIRD shared memory database on initialization.), (Recommended Action: If any problems are seen, they may be rectified by restarting the process using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_LB-4-SESSION_NOT_STOPPED ### Response: (Severity: 4), (Category: L2), (Description: The platform failed to stop a loopback session when requested to do so.), (Recommended Action: If any problems are seen, they may be rectified by restarting the edpl_ma process using the following command: - process restart edpl_ma) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-CHASSIS_RELOAD_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Chassis wide reload operation has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-ERR_CREATESG ### Response: (Severity: 3), (Category: SECURITY), (Description: A configuration error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBMA-5-SVC_NOTICE ### Response: (Severity: 5), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-5-ERR_TCAM_INVALID_REG_NAME ### Response: (Severity: 5), (Category: OS), (Description: A Pre-IFIB region with unrecognized name is found in the TCAM. It is likely caused by a programming bug or a programming problem happened in the past.), (Recommended Action: Check the status of TCAM Manger because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_8_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_8 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-KEXE_INIT_TIMEOUT ### Response: (Severity: 3), (Category: PLATFORM), (Description: TBD.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTNLC_FPD-6-RELOAD_CARD ### Response: (Severity: 6), (Category: OS), (Description: The Working image has been upgraded. NTA reset wont work to bring in the upgraded versions in effect. User will have to reload the card), (Recommended Action: reload the card to bring in the upgraded versions) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-6-SETSOCKOPT ### Response: (Severity: 6), (Category: IP), (Description: An error occurred whilst trying to setsockopt on the socket. Session will continue.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_VLAN_TAGS ### Response: (Severity: 4), (Category: L2), (Description: The LACP protocol will not be able to run on this interface. This may be because the interface has a complex encapsulation configured, which is not supported in conjunction with LACP. Complex encapsulations include: - Matching on source or destination MAC addresses - Matching on payload ethertype - Matching on VLAN tags using the 'any' keyword. In these cases, it cannot be determined how to format the ethernet header for sending LACP packets, and hence LACP is not supported in these scenarios.), (Recommended Action: Ensure the encapsulation on the interface does not use any of the 'complex' matching criteria.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-5-MSG_NDLRSC_CPU_FAILOVER_DELAYED ### Response: (Severity: 5), (Category: PLATFORM), (Description: When an ndlrsc CPU inst on standby DRP failsover as active, its transition to active state is delayed. This is done in order to allow the dlrsc CPU instance to failover first and thus have a predictibility in the failover sequence among CPU instances.), (Recommended Action: None; this CPU will failover to active state with a delay.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_MSG_REPLY ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to reply to its client through message channel. This could be a result of channel down or resource allocation failure.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart the IS-IS process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSCMEDIA-7-ETHSERVER_CONNECT_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: This message indicated DSC fails to open eth server connection. There is might be HB loss issue will be seen on DSC nodes. Check for CE connectivity), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFWD_MA-3-ERR_DEBUG_REG ### Response: (Severity: 3), (Category: ROUTING), (Description: An error related to the debugging subsystem occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_5_LOW_RX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_SERVICES-3-HEARTBEAT_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Heartbeat failure notification from octeons was received by the Services PLIM driver or a critical error occured in the thread monitoring heartbeat from octeons.), (Recommended Action: Do warm reload of the Services PLIM MSC. If the issue persists do a cold reboot of the same. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-6-NETIO_SET_PAK_SHAPEQ_FAIL ### Response: (Severity: 6), (Category: QOS), (Description: Could not set the outgoing queue associated with this packet. As a consequence the packet is being dropped. During normal operation of the system, an occasional (very in-frequent) packet drop in the slow-path is tolerable.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-SW_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An internal software error has occurred for the specified SIM Service Engine.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-LSP_CTX_NON_EMPTY_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error, where LSP context is being deleted while it has valid TLV context queued.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-EVENT_MANAGER_CHANNEL ### Response: (Severity: 7), (Category: HA), (Description: A call to message channel create api failed. process will abort with error.), (Recommended Action: Retry the operation . If error persits, Collect system log information and Contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_SWITCH-2-PLATFORM_INIT_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Switch HAL configuration failed and process will respawn by its own to recover from this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND-2-ERR_INVALID_THREAD ### Response: (Severity: 2), (Category: IP), (Description: Detected single-threaded IPv6 ND code running on an unknown thread. This concurrency can result in corruption. %d/%d indicate actual tid/expected tid.), (Recommended Action: Collect IPv6 ND and check-point traces) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you troubleshoot configuration inconsistencies in IOS XR? ### Response: To troubleshoot configuration inconsistencies in IOS XR, you can use commands like 'show configuration failed' to view any configuration that failed to apply, and 'show configuration inconsistency' to identify mismatches between the running configuration and SDR-specific configurations. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-4-DEV_NOLATCH ### Response: (Severity: 4), (Category: PLATFORM), (Description: Errors seen on the device bus for which information was lost due to other errors or some other condition.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-3-ERR_SET_REBOOT_CAUSE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The failure on setting reboot cause to syspage before performing Kernel Dump.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_UV-3-ERR_DBG_REGISTER_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during initialization of the ospfv3_uv process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB_TOPAZ-7-ERR_EVENT_CONN_EVM_HANDLER ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server encountered an error while trying to register event handler for the posix message queue. This facility is deemed crucial and the process automatically restarts on this failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_LASER_EOL ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_LIST_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The creation of the list to be returned has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_COMM_DRVR-7-ERR_SHM_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: The SFE common infra driver could not initialize shelfmgr.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMACTRLR-4-WARNING ### Response: (Severity: 4), (Category: L2), (Description: A non-fatal error occured while executing the function in question. The message contains info about the location and cause of the failure and possibly anticipated actions/effects.), (Recommended Action: Verify continued correct operation of IMACTRLR.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_TOPAZ-7-ERR_SEND_EGRESS_PKT ### Response: (Severity: 7), (Category: PLATFORM), (Description: Cannot send packet to pdma queue %s - error description %x - QAD queue id %d - 0 ingressq; 1 egressq; 2 fabricq 0; 3 fabricq 1 %x - error code), (Recommended Action: Ignore the message if it only appears once otherwise contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_FSM-3-ERR_SOCKET ### Response: (Severity: 3), (Category: L2), (Description: There is a communication problem with the PPP socket.), (Recommended Action: Restart the ppp_socket process on the node where the error is reported. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-BADFORMAT ### Response: (Severity: 7), (Category: MGBL), (Description: The command entered is badly formatted.), (Recommended Action: Re-enter the command. (Use the help command to find valid entry formats.) If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL-3-MMAP_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Memory maping to get device id failed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPFPGA-3-ZL301x_SPI_ACCESS_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: ZL301x SPI access Failure/Success while accessing.Line is open/short.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-PROTECTION_RULE_NO_OP ### Response: (Severity: 4), (Category: INFRA), (Description: Traffic protection rules define exceptions to the default defined for a particular set of traffic destined to Linux. Rules must have actions with the opposite sense to the parent default-action. The impacted rules will not be applied and so will have no effect on the system.), (Recommended Action: No problems should be seen. To restore consistency between the running configuration and system state, all traffic protection rules should be configured such that their sense is opposite to their parent default-action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-ROUTE_GEN ### Response: (Severity: 3), (Category: ROUTING), (Description: An internal software error occurred during route handling. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBIPV4-7-HSSD_REG_FAIL ### Response: (Severity: 7), (Category: IP), (Description: For generation of ICMP error packets, the ICMP generation library needs to register for an internal packet resource called HSSD. Since, it couldn't register for that, an ICMP error couldn't be generated.), (Recommended Action: This can happen while 'packet' process is restarting and a couple of instances of the message can be ignored in that case. If there is no restart and problems are being seen with the router not being able to send ICMP errors, do the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-3-TCB_FREE_OPEN_SOCK ### Response: (Severity: 3), (Category: ROUTING), (Description: TCB free on open socket.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_MGR-3-SEND_FAILED ### Response: (Severity: 3), (Category: SERVICES), (Description: A control message could not be sent from the MA to the EA. See error message for a possible reason. An interface may now be in the wrong up/down state.), (Recommended Action: Restarting the relevant SVI Manager process will prompt a resync, which should re-send the lost message. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure RSVP fault management in Cisco IOS XR? ### Response: To configure RSVP fault management, use the 'rsvp fault-management' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#rsvp fault-management <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-3-GET_PLACEMENT_LIST ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'l2vpn xconnect' command in IOS XR? ### Response: The 'l2vpn xconnect' command is used to configure a point-to-point Layer 2 VPN (L2VPN) service, also known as Virtual Private Wire Service (VPWS). It establishes a pseudowire between two provider edge (PE) routers to carry Layer 2 traffic. The 'xconnect' command binds an attachment circuit (such as an Ethernet interface) to the pseudowire. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FILECOPY-3-SIGATTACH ### Response: (Severity: 3), (Category: OS), (Description: The filecopy_process was unable attach a handler for a signal. This could affect cleanup of open connections or allocated resources during shutdown, which could affect the filecopy_process' ability to restart in the future. The filecopy_process will attempt to shutdown in the hope that this problem is transient, and that a future attempt to start it will succeed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-FANTRAY_CLEAR ### Response: (Severity: 2), (Category: PLATFORM), (Description: All fans on indicated fan tray returned RPMs to operating level.), (Recommended Action: None required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-5-LOW_MEMORY_STATE ### Response: (Severity: 5), (Category: OS), (Description: System is running out of memory, and hence appropriate action is taken), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS-6-MALLOC_FAILED ### Response: (Severity: 6), (Category: OS), (Description: THE NETIO encountered a problem of memory allocation.), (Recommended Action: Check if there are any possible memory leaks. Please provide the outputs of the following commands: - show memory compare start - Perform the required operation - show memory compare end - show memory compare report.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure BGP to advertise additional paths in IOS XR? ### Response: To configure BGP to advertise additional paths, you enable the feature under the BGP address family configuration. router bgp 65000 address-family ipv4 unicast additional-paths selection route-policy SELECT-ADD-PATHS additional-paths send additional-paths receive commit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'bgp bestpath aigp ignore' command in IOS XR BGP configuration? ### Response: The 'bgp bestpath aigp ignore' command is used to disable the Accumulated Interior Gateway Protocol (AIGP) metric for best path selection. AIGP is an optional, non-transitive BGP path attribute that carries the accumulated IGP metric for the path. By default, if AIGP attribute is present, BGP uses it for best path selection. This command disables the use of AIGP in best path calculation. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-ASIC_INIT_ERR_1 ### Response: (Severity: 1), (Category: FABRIC), (Description: Crossbar fabric interface ASIC-1 failed during init.), (Recommended Action: Reboot the board. If the error persists, contact TAC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-PLATF_UPD_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: When FIB processes forwarding updates, it may have to program the underlying platform hardware. A failure occurred during this programming. This will not normally affect existing traffic but may affect the ability to process forwarding updates.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can BGP be used to migrate from one ISP to another with minimal downtime? ### Response: BGP can facilitate ISP migrations with minimal downtime by allowing routes to be selectively advertised to the old and new ISPs during the transition. The local preference can be manipulated to prefer the old or new path. AS path prepending can be used to influence inbound traffic. Communities can also be used to control advertisement of routes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NCS4K_4H_OPW_QC2-3-MDIO_OPERATION_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: MDIO Operation failed), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBIPV6PROTO-3-NO_MEM_FAIL ### Response: (Severity: 3), (Category: IP), (Description: One of the memory allocation routines such as malloc() fails.), (Recommended Action: Use 'show memory summary [location ]' command to determine the state of the system memory. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERR_INFO_RT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error information related to rate limitor in platform FIB), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_PIDB-2-INIT ### Response: (Severity: 2), (Category: PLATFORM), (Description: A run time error occurred while initializing the pidb on the linecard. The reason for the error is dispalyed. Please call Cisco Support with the error information), (Recommended Action: Please collect output of the following commands: show log show pidb trace show pidb error show pidb debug) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-7-DEBUG_EVENT_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to the failure on debugs events. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-OPERATION_FAILURE_WITH_ERR_ID ### Response: (Severity: 3), (Category: INFRA), (Description: Specified install operation in the error message failed. This will display the error code), (Recommended Action: The reason for this install operation failure has to be analyzed. Check the install operation log by 'show install log ' id is same as displayed in the syslog message which will be helpful to understand the reason for the install operation failure. Collect the show tech logs by running 'show tech-support install' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-2-LC_EOBC_SEND_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: This line card has failed to transmit a heartbeat to a RSP over EOBC.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBIMGR-3-NODEID_TO_IP_ADDR_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cant able to convert my nodeid to ip address, Either an invalid location is being queried, or the infrastructure is behaving incorrectly. The MBI operation in progress may not be carried out. %d - gives the id of the node on which the error occurred. %s - indicates the location of the error. %s - indicates the error message.), (Recommended Action: If the MBI operation does not complete successfully, then further manual action will be required. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-2-BLG_TX_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Interrupt controller FPGA reported that data it received from crossbar fabric arbiter had parity error), (Recommended Action: Please correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_DRIVER-3-INIT_FAILED ### Response: (Severity: 3), (Category: L2), (Description: CPP driver failed to initialize a device.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-bandwidth overflow feature? ### Response: The MPLS TE auto-bandwidth overflow feature allows auto-bandwidth to react more quickly to sudden traffic spikes by triggering an immediate bandwidth adjustment when the measured rate exceeds a configured overflow threshold. It aims to ensure the tunnel can accommodate bursty traffic patterns. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TAMSVCS-6-DB_MIGRATION ### Response: (Severity: 6), (Category: SECURITY), (Description: tamsvcs process successfully migrated the TAM DB from SWTAM to Hybrid-TAM.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCV-4-INVALID_YANG_METADATA ### Response: (Severity: 4), (Category: MGBL), (Description: A problem was encountered while trying to read in Yang metadata while the Central Config Validator (CCV) was initializing. Attempts to modify system configuration while CCV is disabled will not be validated.), (Recommended Action: The failure to read in the metadata should be investigated, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-INTF_NAME_NULL ### Response: (Severity: 3), (Category: MGBL), (Description: 'Interface name send for parsing is NULL.'), (Recommended Action: Collect the nvgen debug output and inform Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: P40X0_DPAA-3-CFG_PORTAL_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: P40X0 datapath was unable to configure a portal. This error could occur for two reasons. 1. The system is low on resources. 2. A hardware error or an error in the DPAA software.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect show log location output, show controllers dpaa trace all location output and show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: telnet-6-INVALID_INTF ### Response: (Severity: 6), (Category: IP), (Description: 'The specified source interface can not be used. Will use default interface'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSVP-3-CHKPT_XFORM_UNSUPPORTED_TYPE ### Response: (Severity: 3), (Category: ROUTING), (Description: The RSVP checkpoint table translation library was invoked with an unsupported translation type.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-INIT_CONFIG_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: The Network Processor didn't get the config complete signal before booting up, it may have booted up with incorrect parameters), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSS-3-ERR_SYSMGR_PROC_READY ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric statistics server process encountered an error while reporting process ready to sysmgr. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_DPM-3-INVALID_MSG ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A SDACP discovery message was received on the interface, but was malformed and could not be decoded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-3-INVALID_PARAM ### Response: (Severity: 3), (Category: FABRIC), (Description: A null or invalid parameter was passed to the above named function. This *may* indicate a serious problem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-5-PRE_FPD_OP ### Response: (Severity: 5), (Category: FABRIC), (Description: Field upgrade of the fabric PLD while the fabric card is in the chassis. Due to a bug in the superstar ASIC, field upgrade of the PLD cannot be done while the card is in service and fabric plane is UP. It is required to halt the ASICs on the board and isolate the plane while the PLD image is being loaded via the JTAG interface. This message posts a notice to indicate that the devices will be halted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARB-5-ERR_CONT ### Response: (Severity: 5), (Category: PLATFORM), (Description: This message indicates an error occurred beyond which execution of the arbiter driver may continue, attempting to effect recovery or work-around internally, minimizing loss of information/functionality.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_3_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-6-DSCP_OPTION_DEPRECATION ### Response: (Severity: 6), (Category: INFRA), (Description: DSCP4 and DSCP6 CLI options will be deprecated since they are no longer supported by ISC DHCP Client. They will be removed in the future.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV6-3-WARNING_INFO ### Response: (Severity: 3), (Category: L2), (Description: A runtime error occurred in ASR9K IPv6 FIB module. The reason for the failure is also displayed. Please call Cisco Support with the error information.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace [common|ipv6] all loc <>). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_ALLOC-7-ERR_DEBUG_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: The FGID Allocator failed to initialize debug. The FGID component and the System should still continue to function as normal, with the exception that the debugs will not be available for fgid_allocator process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-2-CLEARED_CONFIG_INCONSISTENCY ### Response: (Severity: 2), (Category: SYSDB), (Description: Sysdb detected possible configuration inconsistency and successfully cleared it.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_11_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_ALIGN_ERROR_LANE_INDICATE_11 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDL2-3-MSG_GENERIC_FUNC ### Response: (Severity: 3), (Category: OS), (Description: A call to some system function to initialize bcdls failed. bcdls process would shut down when this occurs and will be respawned by the producer.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DOT1X-3-MACSEC_CONFIG_CONFLICT ### Response: (Severity: 3), (Category: L2), (Description: macsec eap is not supported with multi-auth host mode.), (Recommended Action: none) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-MEM_ALLOC ### Response: (Severity: 3), (Category: OS), (Description: It's likely that the system is running low in memory.When this issue happens, it will trigger an automatic restart of pifibm_server_lc process.), (Recommended Action: This indicates a low-memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-INIT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: An error was encountered while the specified process was initializing. The error message contains details about the source of the error.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK temperature greater than or equal to the high temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKP_IPV6_EA-3-ERR_MEM ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Typically, this is an error where the memory allocation / access fails. Here is a list of possible reasons for this message (not all-inclusive). 1) Memory exhaustion due to overall system load 2) Shared memory access failure 3) Memory leaks leading to resource exhaustion), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show memory summary show cef ipv6 location <> show cef ipv6 trace location <> show cef platform trace all all location <> show memory location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-3-DSP_TEMP_OOR ### Response: (Severity: 3), (Category: PLATFORM), (Description: --), (Recommended Action: Turn off the router) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-3-INTERNAL_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: ZTP likely hit an unexpected error.), (Recommended Action: Inspect the error from ztp logs. The error information can be displayed through the following command: show ztp log.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOADPATH-7-NULL_PTR ### Response: (Severity: 7), (Category: INSTALL), (Description: An internal error has occurred in an application that has caused it to pass invalid data to the Package infrastructure. The current request or operation will not be carried out.), (Recommended Action: Retry the command.If it fails, retry the command after restarting the 'instdir' process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSUDIR-1-OPERATION_ABORT_NODE_DOWN ### Response: (Severity: 1), (Category: INSTALL), (Description: ISSU operation aborted because the specified node was not ready.), (Recommended Action: The reason for this issu operation failure has to be analyzed. Check the issu operation log by 'show issu director trace ' and 'show issu' to understand the reason for the operation abort. Collect the show tech logs by running 'show tech-support issu' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATE_OUT_OF_SYNC-6-MONITORING_INTERVAL_OVERRIDEN ### Response: (Severity: 6), (Category: PLATFORM), (Description: On a certain type of ASR9k linecards, different step values are supported in monitoring interval duration configuration. When unsupported value is configured, the closest supported value will override user configuration.), (Recommended Action: No action required. This is informational message to remind user of the fact that system behavior will be slightly different from what is configured by the user.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IP_EA-3-INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An initialization error has occured for IPv4 Forwarding Information Base.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MAC-3-NP_TX_FIFO_RECOVERY_FAILED ### Response: (Severity: 3), (Category: L2), (Description: An inconsistency in the NP Tx FIFO has been detected. An error was detected while the system was attempting to recover from the condition.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-3-PROC_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: BFD proc SM failed because of the timer init failure.), (Recommended Action: Restart corresponding bfd process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_SOCKET-2-PAK_CLNT_ERR_CLNUP ### Response: (Severity: 2), (Category: L2), (Description: The cleanup API failed due to some reason. The argument represents the reason for the failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Collect required info and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-7-MLACP_TLV_CAPTURE_STOPPED ### Response: (Severity: 7), (Category: L2), (Description: TLV capture has been halted on the specified ICCP group due to lack of buffer space. If further capture is required, the current TLVs must be cleared (using the clear mlacp tlv-capture command) and TLV capture explicitly restarted. Captured TLVs may be viewed using the show mlacp tlv-capture command.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_RSI_SRLG_UPDATE ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to register or unregister with RSI for SRLG notifications on the specified interface. IS-IS will reset RSI connection and retry.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-2-LC_EOBC_NO_RSP_UP ### Response: (Severity: 2), (Category: PLATFORM), (Description: This line card found there is no RSP present in the system.), (Recommended Action: This condition should not last long, the line card should reset. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-MISWIRED ### Response: (Severity: 6), (Category: L2), (Description: The Mis-Wiring Detection feature of Ethernet Link OAM has detected a mis-wiring situation. Mis-wiring occurs when the TX wire of an interface is not connected to the same remote interface as the RX wire.), (Recommended Action: Check the wiring of the specified interface. By setting the mis-wiring action to 'log', and using the packet debugging facility of Ethernet Link OAM ('debug ethernet oam packets'), the MAC addresses of the source of packets can be used to identify where the links are.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_BCDL_CONSUMER-3-ERR_DEBUG_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID BCDL Consumer was unable to initialize debug. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REBOOT_LIB-3-REBOOT_CMD_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: Error message that the reboot command failed to execute or complete), (Recommended Action: Collect System log and show-tech processmgr) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SERVER-7-ERR_ATTR_DETACH ### Response: (Severity: 7), (Category: OS), (Description: Failed attr set detach for thread.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-2-CRITICAL_ERROR ### Response: (Severity: 2), (Category: MGBL), (Description: A critical error was encountered. The failure of this can be critical to general system operation. If the same error is seen more than 5 times, contact Cisco TAC support because a reboot of the node may be required.), (Recommended Action: Provide the message details to Cisco Support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_EDM-3-SYSDB_COID_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: The process failed to convert a conn to a coid while starting the indicated subsystem. This generally can only occur when starting up.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_FM-3-VERIFICATION_DB_INCONSISTENCY ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A database inconsistency was noticed in an existing entry in verification database, when applying acl on another interface), (Recommended Action: Reload the affected lc.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-ERR_HW_PROFILE_SOC_PROPERTY_MISMATCH ### Response: (Severity: 3), (Category: FABRIC), (Description: 1. Mismatch found between user configured value and the value used to set soc sal property. Needs attention with RSP card reload.), (Recommended Action: System is inconsistent. Need to reload RSP card for new values to take effect. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_CHUNK_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: Error in allocating memory.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_1_HQ_FULL_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue full error on XAUI 1 HQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-NODEID_EXTRACT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-EDM_LIST_CREATE_FAILED ### Response: (Severity: 3), (Category: OS), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The creation of the external data manager list has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-SYSDB_EDM_INIT_FAIL ### Response: (Severity: 3), (Category: OS), (Description: Falied edm initialization. EDM is very important for OBFL to function. This will restart the process.), (Recommended Action: If the issue is seen after restart then, collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging 5. show tech-support sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RCMD_LIB-5-LABEL_COVERAGE_BELOW_THRESHOLD ### Response: (Severity: 5), (Category: ROUTING), (Description: Threshold configured for RCMD Label Coverage monitoring was reached.), (Recommended Action: Check the Neighbour, Adjacency and Label Received information for the Remote Nodes.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-CREATE_GROUP_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: 'Unable to create GSP group.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-SHUTDOWN_TIMEOUT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Shelfmgr timed out waiting for the given process to gracefully shutdown the given card.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LSPV-7-MSG_INIT_MUTEX ### Response: (Severity: 7), (Category: ROUTING), (Description: Process failed to initialize a necessary system lock required to facilitate debugging and display of database results. This may be occurring due heavy resource utilization on the system.), (Recommended Action: Wait a few minutes and attempt to restart the LSPV_SERVER process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_13 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-7-CHECK_LOG ### Response: (Severity: 7), (Category: OS), (Description: System event occured requiring that specified log to be checked for important information), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-3-PCL_CSLOT_SYNC ### Response: (Severity: 3), (Category: FABRIC), (Description: Sponge encountered a PCL internal error. The asic will be reset to recover from this error.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_ASR9K_NSR_PACKET-2-ERR_TRIMMING_HDR_FROM_PACKET ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message tells is there was an error in trimming the header from the packet.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cpposlib-3-CLEAN_NOTIFY ### Response: (Severity: 3), (Category: L2), (Description: A function failed to cleanup.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VRRP-3-ERR_NO_MEM ### Response: (Severity: 3), (Category: IP), (Description: The VRRP process was not able to allocate the memory that it needed to complete the operation. VRRP functionality may be reduced until the problem is resolved.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-7-DUP_KEY ### Response: (Severity: 7), (Category: HA), (Description: A client of the checkpoint library attempted to create an object with a key that was already in use.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-VCCINT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: VCCint out of range), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AMT-3-ERR_MALLOC ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MARVEL-3-MMAP ### Response: (Severity: 3), (Category: L2), (Description: mmap() system call failed to map the device physical address.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SECURE_VAULT-6-CORE_START ### Response: (Severity: 6), (Category: SECURITY), (Description: The Secure Vault process has been enabled and the core elements have been started successfully.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-TABLE_OPERATION_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-ADJCHANGE_DETAIL ### Response: (Severity: 5), (Category: ROUTING), (Description: A BGP neighbor has either come up or gone down. This message appears only if the bgp log neighbor changes detail command is configured for the BGP process. This is the detailed variant of the neighbor state change message. Included in this message is a list of AFI/SAFI which were advertized (supported) by each end of the session and are common to both. The AFI/SAFI values are defined in RFC 1700, RFC 4760.), (Recommended Action: This informational message normally appears as routers and BGP neighbors go up or down. However, unexpected neighbor loss might indicate high error rates or high packet loss in the network and should be investigated.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_PRM-3-PROCESSING_FREE_ENTRY ### Response: (Severity: 3), (Category: PLATFORM), (Description: The specified error happened during processing of the delay freed entry.), (Recommended Action: Please collect output of the following commands: show platform show platform vm show log show process blocked location <> show process fib_mgr location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_FPOE_DB_UCORR_ECC_ERROR_LNK3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast FPOE uncorrectable ECC error on link 3), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-RESET_RECOVERY_DISABLED ### Response: (Severity: 3), (Category: INFRA), (Description: When the Ethernet Switch Driver (ESD) process encounters certain switch errors, it initiates a switch reset recovery operation. This involves resetting the switch and then exiting the ESD process so that it is restarted by the process manager. When the reset recovery operation has been disabled via process command line options, ESD does not take action to recover from the failure so that the problem can be investigated further.), (Recommended Action: Switch reset recovery is typically disabled in order to reproduce and investigate a switch failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSM-5-RECOVER_LOG ### Response: (Severity: 5), (Category: OS), (Description: SSM Process detected a failing service. No recovery action taken.), (Recommended Action: Collect show tech ssm. 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ARM-6-CFLCT_NO_LONGER ### Response: (Severity: 6), (Category: IP), (Description: The IP address specified in the message previously conflicted with other configured IP addresses on some portion of the network portion of their IP addresses. The IP address no longer conflicts.), (Recommended Action: None. This is an informational message indicating a return to a correct consistent configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2RIB-3-GEN_ERR ### Response: (Severity: 3), (Category: L2), (Description: An internal software error occurred), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_8_HIGH_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-INVALID_METRIC ### Response: (Severity: 4), (Category: ROUTING), (Description: Metric 0 is not allowed on transit links by RFC2328. Forcing SPF to use metric 1 instead.), (Recommended Action: Prevent the sourcing router from advertising transit links with metric 0 by reconfiguring it or installing a software update) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PERF_MEAS-5-CONTROL_CODE_ERROR ### Response: (Severity: 5), (Category: ROUTING), (Description: An error has been sent by the session responder. Additional information regarding the error can be found in RFC 6374 section 3.1. The session has been stopped until the recommended action is taken.), (Recommended Action: Once the error has been resolved it may be cleared using clear performance-measurement delay interfaces . The session will be resume once the error is cleared.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-JACKET_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cctl_spa_server process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process cctl_spa_server location <>' to verify that the process is up and running.If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-ERR_INVALID_HW_POLICE_CIR_CBS ### Response: (Severity: 4), (Category: OS), (Description: Policer Rate causing CIR (kbps) and/or CBS to exceed max value in HW.), (Recommended Action: Reduce the policer rate to make CIR/CBS within 32-bit value in kbps.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_LOL_MAPPERA ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to verify the status of an L2VPN pseudowire? ### Response: To verify the status of an L2VPN pseudowire, use the 'show l2vpn atom vc' command. show l2vpn atom vc <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_13_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_13 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCSQ_DLL-4-ERR_ASIC_SN_LINK ### Response: (Severity: 4), (Category: FABRIC), (Description: CCSQ, cpuctrl net interface Rx FIFO last sync.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_MCAST_JOIN_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS was unable to join the specified multicast group on the specified interface, Will retry again.), (Recommended Action: Restart the affected interface and, if the problem recurs, the IS-IS process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-4-PROGRAM_ERRORED_POLICER ### Response: (Severity: 4), (Category: OS), (Description: An internal error was detected when trying to program the flow policer.When this issue happens, it will trigger an automatic restart.), (Recommended Action: Check the status of Metro IPC Server because this issue is likely related to it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD-7-SPECIFY_PLIM_INTERFACE_RETRIES_COMPLETE ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: All queued retries from forwarder to its NetIO DLL have been completed successfully. The two are now in sync and all slow-path forwarding should be operational.), (Recommended Action: None - this is an indication of an error situation clearing.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPU_PKT_F1_MBE ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPU packet FIFO 1 multiple bits error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-SYSDB ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred when accessing the system database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospfv3 - show ospfv3 trace all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-EEPROM_PROTOCOL_EVENT_CONN_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_6_HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature greater than or equal to the high temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the primary purpose of the IS-IS routing protocol? ### Response: IS-IS is an IGP used to distribute IP routing information throughout a single autonomous system (AS). It is a link-state protocol that uses the Shortest Path First (SPF) algorithm to determine the best path to a destination. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMS-3-EMSD_FAILURE ### Response: (Severity: 3), (Category: MGBL), (Description: emsd encounted failure.), (Recommended Action: check if emsd was started with appropriate configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCMCIAD-7-RESTART ### Response: (Severity: 7), (Category: PLATFORM), (Description: pcmciad died and had come back up. It is killing children spawned by old pcmciad so that it can respawn new ones.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture console log and process core of process pcmciad if available.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-6-EA_DEBUG_INIT_FAIL ### Response: (Severity: 6), (Category: QOS), (Description: Debug initialization failed within EA. Debugs may not be printed), (Recommended Action: Try restarting QoS EA process get the JID by 'show processes qos_ea location <>' 'process restart location <>') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SLA-6-RESYNC_PROFILE_INVALID ### Response: (Severity: 6), (Category: INFRA), (Description: The SLA Client Library is discarding a profile that was found to no longer be valid during a resync. Any operations using this profile shall be suspended and their associated metrics removed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-TIMER ### Response: (Severity: 4), (Category: L2), (Description: PTP MA encountered an error using the timer wheel library. The error message describes what operation has failed and why it failed. The error could also be caused by low memory resources or programming error.), (Recommended Action: Consider restarting the PTP MA process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_DEBUG_INIT_EVENT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA_MGR-3-MPA_EJECTOR_OPEN_POWERDOWN ### Response: (Severity: 3), (Category: PLATFORM), (Description: Shutdown command received for MPA due to open ejector), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SCHBRO-7-AUTHENTICATE ### Response: (Severity: 7), (Category: MGBL), (Description: An error occurred invoking an AAA function. The details are in the error string), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: spp-3-CTX_DOUBLE_FREE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The identified client attempted to free the context which has already been freed.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install verify process command in IOS XR? ### Response: The 'install verify process' command is used to verify that all the necessary processes are running after an installation operation. It checks the status of critical processes and reports any issues found. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_LCPM_SHOW-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: VKG_LCPM_SHOW encountered an error), (Recommended Action: Please enable 'debug sysdb access ...' and capture the output.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_TDM-7-NO_TRANSLATOR ### Response: (Severity: 7), (Category: HA), (Description: A required translator was not loaded.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: adminexec-3-PTHREAD_CREATE ### Response: (Severity: 3), (Category: MGBL), (Description: Unable to create exec's event handling thread), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLUSTER_CLM-6-UPDN ### Response: (Severity: 6), (Category: PLATFORM), (Description: A link to the RSP control plane switch has change state.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log. Issue the show nv edge control control-link-protocols location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show nv edge control control-link-protocols location output, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-3-FORWARD_PACKET_TO_UNALLOCATED_QUEUE ### Response: (Severity: 3), (Category: L2), (Description: Egressq driver detected that packets were sent to an Egressq queue which is unallocated. These packets will not be serviced and will remain in the queue until this queue is allocated and becomes active, or asic reset or linecard reload.), (Recommended Action: If this message appears more than once in response to the specific action taken or if the message indicates a large number of bytes (more than 10MB) in an unallocated queue(s), Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-ACP_CHANNEL_TO_NBR_REMOVED ### Response: (Severity: 6), (Category: SERVICES), (Description: 'Autonomic Network Control Plane Channel to neighbor ' 'is removed'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-0-INIT_RETRY_SUCCEEDED ### Response: (Severity: 0), (Category: MGBL), (Description: An error was previously encountered while initializing one of the critical modules of the configuration manager server. However, the initialization was retried and succeeded.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-1-ERROR_HW_IMDR ### Response: (Severity: 1), (Category: FABRIC), (Description: Ingressq Driver encountered an error during imdr event. This may have been caused because expected or unexpected software and hardware errors. In any case, imdr on the line card will be aborted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ILITE-3-WRITE_REG_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Write to register has failed.This may be a program level error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-HARD_RESET_INTERRUPTED ### Response: (Severity: 4), (Category: PLATFORM), (Description: npu_server has restarted while NP hard reset is in progress. The hard reset will re-start to recover the NP), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DCL_LIB-2-NULL_PTR ### Response: (Severity: 2), (Category: HA), (Description: An expected data pointer was not found.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_QOSEA-2-TMPORT_PROG_ERROR ### Response: (Severity: 2), (Category: QOS), (Description: Unable to program tmport object for an interface. The message will provide further details on the error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_AAA ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the AAA service. The error message describes what operation has failed and why it failed. The most likely reason for this is a temporary problem communicating with the AAA server, but the error could also be caused by low memory resource or programming error.), (Recommended Action: In many cases, PPP MA will recover by itself. If it does not then restarting the process may help. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-STATEMC_0_ERR1_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: State machine - 0 ran into error-1 on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-ERR_NH_PACK ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected nh notification packing error occured.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EDRM_DLL-3-SERVER_INIT ### Response: (Severity: 3), (Category: L2), (Description: The initialization of the DLL from the server side failed due to the indicated reason.), (Recommended Action: None. The initialization will be retried automatically.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_VCM-3-VC_EXISTS ### Response: (Severity: 3), (Category: L2), (Description: The DLCI is unique per 'main' interface and this dlci is already used), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IEP-3-DAEMON_ERR_SYSDB_BSCAN ### Response: (Severity: 3), (Category: IP), (Description: An error occurred while using SysDB.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_10_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_OOB_ERROR_LANE_INDICATE_10 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONFIG-6-DB_FREE_LAST_COMMIT ### Response: (Severity: 6), (Category: MGBL), (Description: Even last commit is deleted to free up space for next commit.), (Recommended Action: Delete any unnecessary files from the config disk.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-GROUP_ADD_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace group error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace group error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-4-QFP_FAILURE_SPI4_SYNC ### Response: (Severity: 4), (Category: L2), (Description: Failed to synchronize SPI4 bus between SPA bridge controller and packet processing engine), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers QFPCPUBridge trace <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers QFPCPUBridge trace <> output, call your Cisco technical support representative and provide the representative with the gathered information. before reloading the line card If this problem persists, reload the line card using hw-module location <>/<>/CPU0 reload) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO_API-3-BIND_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'CTRLIO Connection establish failed.While opening' 'event manager connection for sending data.'), (Recommended Action: 'Connection establishment will be retried by ISSU manager.' 'If the issue persists ' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show isis mpls traffic-eng tunnel' command in IOS XR? ### Response: The 'show isis mpls traffic-eng tunnel' command is used to display information about how IS-IS is interacting with MPLS TE tunnels. It shows the tunnel name, the destination, the cost, and the path used by the tunnel. This command is useful for verifying that IS-IS is considering TE tunnels in its path calculations. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-3-RULES_NO_ID ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A rule with no static id is found in rules file. Every rule should have a static id assigned to it.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP_VRF-3-NOTIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: A notification of a configuration change could not be applied, leaving the internal data structures inconsistent with the configuration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_MSG_GET_SCOID ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to retrieve its local connection ID for a client attached to the specified channel. This is an internal programming error.), (Recommended Action: Restart the IS-IS process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_CFG-2-BUNDLE_PINDOWN_REJECTED ### Response: (Severity: 2), (Category: FABRIC), (Description: This cmd should be configured only in fretta chassis containing Jericho cards only), (Recommended Action: Remove the config on J2 native platforms.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-USER_RESET_REJECTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that the node is unable to comply with a requested user reload request.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-2-CLUSTER_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The cluster is configured without the necessary cluster license.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-4-BLOCK_PROTECTION_DISABLED ### Response: (Severity: 4), (Category: DRIVER), (Description: Block protection should not be configured if we are running non-secure boot image. This can happen in two scenario: - User used iofpga_write_bootflash without '-d' option so after downgrade to non-seecure boot first article image, the flash was still protected. - The flash is a SPANSION part that was bad configured, so it is protected by default after every power-cycle.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-PKT_LEN_ERR_0_FIA_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet length error from FIA for NPU-0 on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-SOCK_SET_NAME ### Response: (Severity: 3), (Category: ROUTING), (Description: An operation failed during packet reception.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-SPI_DATA_CHECK_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: The power-on switch programming from the SPI flash based configuration is in-correct.), (Recommended Action: Check SPI flash programming and install image with correct programming.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: G709-4-log_overflow ### Response: (Severity: 4), (Category: L2), (Description: The logging buffers have overflowed, and reached a point were there is no buffers available.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-INTERFACE ### Response: (Severity: 3), (Category: ROUTING), (Description: CLNS could not initialize its interface.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DHCPD-3-CHKPT_FAILED ### Response: (Severity: 3), (Category: IP), (Description: The error occurred due to failure in checkpoint creation either due to the checkpoint were tried to be written on non-active node or due to some internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_HFR-3-ERR_QAD_SET_WM ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to set the watermark of the indicated qad queue. This should be because of some issues with the qad queue %s - high or low watermark %p - QAD queue id), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_ND-3-ERR_MEM ### Response: (Severity: 3), (Category: IP), (Description: Cannot allocate memory to carry out an important task), (Recommended Action: make sure that there is enough memory then restart ipv6_nd) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TCP-2-AO_DUPLICATE_ID_ON_OVERLAPPING_KEYS ### Response: (Severity: 2), (Category: IP), (Description: Same Send ID or Receive ID is NOT valid to be configured across the keys which has overlapping send or accept lifetime respectively. User has mis-configured the key and it does not meet above crieteria. TCP-AO will not use this key for any new connection, existing connection will continue to use it till send lifetime.), (Recommended Action: Please correct the configuration. No need to re-configure it under BGP or to clear BGP neighbors.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-PCIE_TX_FIFO_MBE ### Response: (Severity: 0), (Category: PLATFORM), (Description: CIB PCIe Tx FIFO multiple bits error.), (Recommended Action: Reset the board) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MLIB-2-OOR_ROUTES_RED ### Response: (Severity: 2), (Category: ROUTING), (Description: MFIB on the node has detected the number of multicast routes has exceeded the prescribed limits and new routes have been blocked.), (Recommended Action: Take immediate action to delete multicast routes from the system.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-6-AUTHEN ### Response: (Severity: 6), (Category: SUBSCRIBER), (Description: A VPDN session has been terminated due to authentication-related error), (Recommended Action: Please examine the user credential against AAA authentication database such as RADIUS profile. Also check similar authentication info at peer side such as local authentication info on LNS or RADIUS profile used by LNS) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKWATCH-4-DEPLETION_WARNING ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: The depletion level of the specified packet resource has reached warning level. If the depletion level does not improve then routing protocols on the impacted node will not be able to allocate packets and the software packet path will be impacted. At warning depletion level, critical services on the node should still be able to allocate packets and thus shouldn't be impacted.), (Recommended Action: Customer should monitor depletion levels using 'show packet-memory' commands. If packet memory remains depleted for significant period of time then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-EVENT_CONN_NOTIFY_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: During initialization, IS-IS failed to register for essential notifications regarding the state of the connection for the specified service. This is an internal error. It requires a restart of the process for recovery.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-4-BADLSATYPE ### Response: (Severity: 4), (Category: ROUTING), (Description: The router received an LSA with invalid LSA Type. The cause is either memory corruption or unexpected behavior on a router.), (Recommended Action: Check both the sending and receiving routers for memory corruption. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ACTIVE_GRANGE_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an interface in Cisco IOS XR? ### Response: To configure an interface, enter interface configuration mode using the 'interface' command. RP/0/RSP0/CPU0:router#config RP/0/RSP0/CPU0:router(config)#interface GigabitEthernet0/0/0/0 RP/0/RSP0/CPU0:router(config-if)#ipv4 address 192.168.1.1/24 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-3-MEMORY ### Response: (Severity: 3), (Category: SECURITY), (Description: radiusd has failed to allocate the required amount of memory.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_0_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_0 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-6-SWITCH_DATA_INTEGRITY_ERROR ### Response: (Severity: 6), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process detected a data integrity event, whenever Parity/ECC memory error is occured on switch. switch will be reset when error counter increases the threshold value. For some critical memory threshold value can be 0.), (Recommended Action: To determine why this problem occurred, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support ' 'control-ethernet' and 'show tech-support ctrace' commands.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_RX_LASER_CASE_TEMP ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-6-PMBIST_MSG ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message in the NPU Driver to indicate a PMBIST operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBCORE-3-EDM_REG ### Response: (Severity: 3), (Category: SNMP), (Description: An attempt to register/unregister path/port into sysdb_edm got failed. It will also print reason of failure as well.), (Recommended Action: Collect following outputs: - show logging - show tech-support sysdb - show sonet-local trace info location <> - show sonetmib trace location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LS_PRM-3-PROFILE_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error from performance profiling action.), (Recommended Action: Please collect output of the following commands: show platform show platform vm show log show process blocked location <>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSMGR-4-MANDATORY_REBOOT_ABORTED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-3-ERR_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: The Ingressq driver failed to initialize the device resulting in the restart of the Ingressq driver process.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the ingressq driver is up and running by executing the following command at the CLI of the active RP: 'show process ingressq location < >' If it is still non-operational, enable the following debugs of the ingressq driver process: error Errors in the driver fatal Fatal errors which cause driver to exit info All informational events init Initialization events and restart the driver by executing the following command at the CLI of the active RP: 'process restart ingressq location < >' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEXMGR-3-CORR_ECC_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PCIE device correctable ECC error), (Recommended Action: This error is a momentary error and software should be able to correct it. No action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-INVALID_PLATFORM_TYPE ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC driver cannot handle the detected CCC platform type.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSUDIR-4-OPERATION_ISSU_ABORT_STARTED ### Response: (Severity: 4), (Category: INSTALL), (Description: The ISSU operation with the given identifier has aborted. Further information on the reason for the abort may be provided by the output of 'show issu'.), (Recommended Action: The ISSU will be held following an abort to enable system level triage. When complete issue command install activate issu abort cleanup or install deactivate issu abort cleanup (as appropriate) to restore the system's RP redundancy and enable another ISSU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-3-DB_INVALID_FREE ### Response: (Severity: 3), (Category: L2), (Description: An internal inconsistency was identified while performing some operation on the database. The process will attempt to recover a consistent state, and should be able to continue operating. It is possible that some parts of the dataplane may become out of sync.), (Recommended Action: If additional problems are observed then restarting the process may help to restore the system to a consistent state. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POS-3-ERR_FIM_REG ### Response: (Severity: 3), (Category: L2), (Description: While initializing the POS component, the Fault Injection module (FIM) registration got failed.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - Check for memory usage, this is a very rare case) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-APIV_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: TBD.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-MGMT_TTY_DETAILS_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: The show line command was unable to get details about the mnemonic for the TTY.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_1_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_1 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-4-QFP_FAILURE_SPA_UPDATE_NULL_BAY ### Response: (Severity: 4), (Category: L2), (Description: Null pointer to data structure when attempting to update SPA status), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers QFPCPUBridge trace <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers QFPCPUBridge trace <> output, call your Cisco technical support representative and provide the representative with the gathered information. before reloading the line card or spa. Try to recover from this error by reloading the SPA with hw-module subslot <>/<>/<> reload or reloading linecard with hw-module location <>/<>/CPU0 reload If this problem persists, please report it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-MAX_IMPORT ### Response: (Severity: 3), (Category: ROUTING), (Description: There is a hard coded limit on the number of tables that a route may be imported into. This limit has been exceeded, so the route may not be present in some of the importing tables. The limit is such that this message should not be seen under normal operation.), (Recommended Action: Review the configs and make necessary changes.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Overload Bit (OL bit) in IS-IS? ### Response: The Overload Bit is used to signal that IS-IS will advertise its LSPs with the OL bit set for a period of time. When the OL bit is set on a new router that comes online, other routers will route around it until its tables converge. The OL bit is then cleared and traffic is routed normally. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF-3-ERR_RESOURCE_ALLOC ### Response: (Severity: 3), (Category: ROUTING), (Description: Allocation of the specified resource failed because of a low memory condition. This could affect the protocol functionality.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands and preferably restart the OSPF process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_EA-3-PLAT_UPD_FAILED ### Response: (Severity: 3), (Category: L2), (Description: Platform update failed.), (Recommended Action: restarting ipv6_ea may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-LANE_1_LOW_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser bias less than or equal to the low laser bias alarm threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-INTERRUPT_ERR ### Response: (Severity: 3), (Category: L2), (Description: The PLIM process failed to handle an interrupt.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed. The most common type of failure is an XFP OIR.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PVSTAG-4-CFG_BATCH_FAIL ### Response: (Severity: 4), (Category: L2), (Description: A failure occured when applying a batch of configuration changes. PVSTAG may not operate correctly following this error.), (Recommended Action: Unconfigure the affected configuration, commit the change, then reapply the configuration. If a failure is still seen, it may be possible to resolve it by restarting the pvstag-io process on the affected line card using the 'process restart pvstag-io location ...' command. Otherwise, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FILECOPY-3-NOMEM ### Response: (Severity: 3), (Category: OS), (Description: No memory to perform edm or bag operations.), (Recommended Action: This indicates a low memory condition. Collect memory stastics using following command. Copy the error message exactly as it appears on the console or in the system log. Issue the show memory command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show memory output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show process memory command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show process memory output, call your Cisco technical support representative and provide the representative with the gathered information. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEMGBL-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: An unexpected condition encountered.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_EDM-3-SYSDB_BAG_ENCODE_FAILED ### Response: (Severity: 3), (Category: IP), (Description: IPv4 Management Agent encountered failure in encoding the bag that is supposed to carry encoded information to be passed on clients of IPv4 MA. Typically the client is a managebility agent like exec spawned by show CLI. As a result of this error the client may not receive the intended information from IPv4 MA. If it is a managebility request that triggered this, the request may be retried. Typically this error is caused if there is mismatch between the bag format and the information to be encoded. At other times the error might be due to process' memory corruption or low memory.), (Recommended Action: Collect the output of show tech-support, show ipv4 ma trace location <> when this message is seen. Identify if possible which manageability requests triggers this message. Most likely it would be one of the show ipv4 CLIs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-5-NSR_CONFIG_ENABLE ### Response: (Severity: 5), (Category: ROUTING), (Description: ISIS nsr is either configured, or deconfigured, or enabled or disabled. In the ISSU case, nsr can be enabled but not configured.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL_SIP700-0-EVT_INIT_FAILURE ### Response: (Severity: 0), (Category: PLATFORM), (Description: The CPU Control driver failed to initialize the event manager. The effect is that the line card may not function or may not function appropriately. The CPU Control driver provides low level services on the SIP 700 Line Card (LC). These include, among other things, access timeout interrupt services and bus parity error interrupt services. The CPU Control driver relies on an event manager to communicate with other components on the SIP 700 LC. If event manager services are not available then the driver process is exited, respawned and the initialization retried. The CPU Control driver is a mandatory process. If the initialization continues to fail after several retries the LC will not properly boot and will reset itself. This error is generally indicative of a larger LC-wide problem. %s - description of the specific failure encountered %s - error detail, if appropriate), (Recommended Action: This error is unlikely to occur by itself nor is it likely to be the root cause of the problem. Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers CPUCtrl ltrace location <>/<>/CPU0 command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers CPUCtrl ltrace location <>/<>/CPU0 output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RUMP-6-GRACEFUL_RESTART ### Response: (Severity: 6), (Category: ROUTING), (Description: RUMP is restarting because the corresponding RIB proc restarted.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSVP-5-BAD_RSVP_MSG_RCVD_AUTH_KEY ### Response: (Severity: 5), (Category: ROUTING), (Description: The router received an RSVP message with a bad integrity digest. RSVP discarded the message because the digest verification failed. The received key ID specified is not currently active/configured.), (Recommended Action: Check the configuration on the router and sending system to make sure that the authentication configuration is compatible. Especially ensure that the configured key ID's match and are active/enabled.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA-4-OOR_YELLOW ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is a severe error message in the OFA module to indicate high usage of OFA resources.), (Recommended Action: Please collect the OFA resource information (show controller npu resources all location all). Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZTP-3-BOOT_IMAGE_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: Failed to install image via ZTP.), (Recommended Action: Inspect the error from install logs. The error information can be displayed through the following command: show install log id detail.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-6-BCM_DVC_EVENT ### Response: (Severity: 6), (Category: PLATFORM), (Description: BCM T2+ device has notified about an event which may or may not be of ciritcal severity. In case, it is critical prm_server will recover on it's own. No explicit action to be taken.), (Recommended Action: No action needed from user.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-PARAMETER_BAD_EVENT ### Response: (Severity: 7), (Category: INSTALL), (Description: An invalid parameter has been unexpectedly passed to the Install infrastructure. This is a coding error. The current request or operation will not be completed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-INIT_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging | inc err command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging | inc err output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show processes igmp detail command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show processes igmp detail output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-NPU_0_CONST_BP_2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: NPU-0 is constantly backpressuring bridge instance-2.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTS-6-INFO ### Response: (Severity: 6), (Category: IP), (Description: An informational message about an event that occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_GBL_CFG-4-ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: The PPP GBL CFG process failed to initialize correctly.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_QOSEA-3-SHMWIN_ERROR ### Response: (Severity: 3), (Category: QOS), (Description: The SSE QoS EA module encountered a shared memory error. The message will provide further details on the error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_DM_INTR_VM_IFIFO_ORUN_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_DM_INTR_VM_IFIFO_ORUN interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-3-ALARM_INDICATION ### Response: (Severity: 3), (Category: PLATFORM), (Description: Alarm indication received from CBC. This may be a serious failure (example: power sequencer failure), however process may continue functioning as expected (or successfully retry) despite the failure.), (Recommended Action: Provide the following CLI: (admin)# show env Use the pid from canb-server output to look for matching pid in the pfm output. If the alarm indication does not clear within 30 minutes, contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-AIPC_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-4-WARN_BNDL_MBR_ADD ### Response: (Severity: 4), (Category: ROUTING), (Description: For various reason PD can return error, we will retry later to see if PD can handle the update.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-3-NETLINK_MSG_ALLOC_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: libnl failed to allocate a message for querying the interfaces in a network namespace.), (Recommended Action: If the system is experiencing memory exhaustion, resolve the underlying issue then restart the process. If the problem persists, Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP-3-COMMS_INIT_FAIL ### Response: (Severity: 3), (Category: IP), (Description: An error occurred while initialising the Comms module. ARP has scheduled a retry for this operation. ARP will not be able to synchronise data between the V1 and V2 process until this is resolved.), (Recommended Action: As there is a retry mechanism in place the process may recover by itself. If the issue is seen repeatedly Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-4-RATE_LIMIT_WARNING_MP_HIGH_WATERMARK ### Response: (Severity: 4), (Category: L2), (Description: BFD has allocated 90 percent of its multipath-specific packet per second allowance or maximum number of BFD sessions on every multipath-configured linecard in the system), (Recommended Action: Either configure new BFD multipath linecards or limit the number of new BFD sessions for the multipath-configured linecards.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAP-3-INV_CONN_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: Indicates that MLAP will not be able to rise alarms on any faults.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-6-ENFORCE_METERED_USAGE ### Response: (Severity: 6), (Category: LICENSE), (Description: Smart Licensing is enabled with post-paid billing method.), (Recommended Action: 'INFO') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-3-ASYNC_SOCKETS_NOT_SUPPORTED ### Response: (Severity: 3), (Category: IP), (Description: A client has performed an operation in the mgmt VRF on an async socket. This is not supported.), (Recommended Action: The information in required_info to be collected and engineering team to be notified. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-INSTORCHAGT_INIT_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: The Orchestration Agent (instorchagt) failed to start correctly), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOR-7-NOMEMORY ### Response: (Severity: 7), (Category: INSTALL), (Description: The requested operation could not be accomplished because of a low memory condition.), (Recommended Action: This indicates a low memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_IPV6_EA-3-ERROR1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: SSE IP-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPIO_PD-3-INVALID_PID ### Response: (Severity: 3), (Category: PLATFORM), (Description: Protocol packet path initialization failed due to invalid protocol ID provided by protocol module. Initialization is aborted and may be retried.), (Recommended Action: Restart the protocol process. 'process restart location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-BADMAGIC ### Response: (Severity: 3), (Category: SECURITY), (Description: 'An internal software error.'), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-4-FILESYSTEM_SYMLINK_MODIFIED ### Response: (Severity: 4), (Category: INFRA), (Description: The locations of installed XR files on disk are maintained by the install infrastructure using symbolic links. At least one of these links has been modified. This can be a malicious attempt to change the running software.), (Recommended Action: Ensure that only authorized people have access to the router. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-5-MLACP_DEVICE_MISCONFIGURATION ### Response: (Severity: 5), (Category: L2), (Description: There is a misconfiguration between a peer device and the local device.), (Recommended Action: Ensure that the configuration (on both local and peer device) is as expected. The message indicates the initial area to check.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFEA_IPV4_EA-3-ERROR3 ### Response: (Severity: 3), (Category: PLATFORM), (Description: AFEA IPV4-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_3_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser bias greater than or equal to the high laser bias alarm threshold. The CPAK is the pluggable optics on the line cards. The laser bias threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC_CTRL-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message from DSC-CTRL process.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-FAILED_ENS_INIT ### Response: (Severity: 3), (Category: INSTALL), (Description: The install director was not able to initialise its event notification service. The system will not be able to perform any installs without this initialisation succeeding.), (Recommended Action: The system will not be able to perform any install operations. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_CFG-2-IPV6_CUSTOM_LEM_NIBBLE ### Response: (Severity: 2), (Category: FABRIC), (Description: IPv6 custom lem config is not nibble granular, config is rejected.), (Recommended Action: None If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER_SNAP-4-DUMP ### Response: (Severity: 4), (Category: OS), (Description: A non-invasive voluntary coredump requested by the process. Process might be experiancing a condition which needs investigation. This core file will help analysing the issue.), (Recommended Action: This should not occur in normal conditions, please provide the coredump to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_EM-7-FMS_EVM_FILE_ATTACH ### Response: (Severity: 7), (Category: HA), (Description: The event_file_attach function reported an error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-3-MEMORY ### Response: (Severity: 3), (Category: SECURITY), (Description: tacacsd has failed to allocate the required amount of memory), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETHER_CTRL-3-PORT_INDEX_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-THREAD_ATTR_SET_FAILED ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: Packet server unable to set the thread's attributes.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-6-INFO_GENERAL ### Response: (Severity: 6), (Category: SECURITY), (Description: The sshd encountered some problem in genric nature or plain information.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_15_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_15 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-3-CALL_IPC_NOTIFY ### Response: (Severity: 3), (Category: SUBSCRIBER), (Description: An IPC notification was received that indicates an error. 1 or more sessions may not establish or may be torn down.), (Recommended Action: Allow the subscribers to reconnect. If the problem persists, you may need to restart vpdn_mgr and/or this client process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the insthelper process in IOS XR installation? ### Response: The insthelper process assists the instdir process by performing file-related operations on behalf of instdir, such as copying files from the router to the TFTP server or vice versa. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-IN_MEM_ERROR_LNK0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected an input memory error on link 0), (Recommended Action: This alarm is transient and should auto-clear when error condition is resolved. If the alarm doesn't clear, then please reload the card using command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SUB_UTIL-4-TRACE_INIT ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: This is a non-fatal error in initializing tracing buffer and can happen when the router is low on memory. It should not affect the functioning of the router, but trace messages may not be logged.), (Recommended Action: Check the memory state of the ltrace process and overall system. Reduce the activities on the system if required for tracing.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFM-3-INTERNAL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: bfm encountered an error and is not able to recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_2_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_2 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-EVENT_CONN_OPEN ### Response: (Severity: 3), (Category: OS), (Description: An internal error was detected when trying to open event connection.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ct_agent-3-ERR_SYSDB_DATALIST ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEMGBL-5-LTRACE_INIT_FAIL ### Response: (Severity: 5), (Category: PLATFORM), (Description: Ltrace initialization failed within INV. Ltraces may not be printed.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-6-RELOAD_NODE_INFO ### Response: (Severity: 6), (Category: INSTALL), (Description: The installation required a reload of this node, and this is now going ahead.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-EA_START_FAILED ### Response: (Severity: 3), (Category: FORWARDING), (Description: The tunl_gre_ma process failed to feature start tunl_gre_ea on one or more LCs via IM, tunnel creation has failed. Tunnel configuration should be retried again after all the LC are UP), (Recommended Action: Tunnel configuration should be reapplied when all the LC are UP) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-ERR_GENTRY_GET ### Response: (Severity: 3), (Category: OS), (Description: The system failed to get gentry.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If the issue persist, you will need to reload the linecard.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-6-BOOT_DEVICE_FORMAT_REQUESTED ### Response: (Severity: 6), (Category: MEDIA), (Description: The media storage card specified was requested to format and will be formatted through the reload.), (Recommended Action: Media storage data should be recovered from either active card or current primary mirroring device. If not redundant card or no mirroring then reinstall software and configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR auto-tunnel backup nhop-only feature? ### Response: The MPLS TE FRR auto-tunnel backup nhop-only feature restricts auto-tunnel backup tunnels to only the next-hop (NHOP) router on the path to the tunnel destination. It does not allow creation of backup tunnels to the next-next-hop (NNHOP) router. This reduces the number of auto-backup tunnels created and the associated overhead, but may provide less protection coverage. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MADISORN-4-SPP_WARNING ### Response: (Severity: 4), (Category: OS), (Description: An error has occured while interacting with PIRD/SPP.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-6-GSP_TRACE_HDR ### Response: (Severity: 6), (Category: OS), (Description: --), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRLLIB-3-HW_DETECTED_ERROR_RX_PDMA ### Response: (Severity: 3), (Category: PLATFORM), (Description: The cpuctrl driver detected a buffer marked with an error, possibly a CRC check. The buffer is discarded.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSA-3-ERR_SYSDB_EDM_REG ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric statistics aggregator process encountered an error to register EDM to admin plane sysdb server. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FWD-3-USAGE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Startup option supplied to FWD is not valid.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed the there is no need to take any action. Otherwise Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_RP-6-EVENT_TIMEOUT ### Response: (Severity: 6), (Category: PLATFORM), (Description: The L2VPN software was waiting for the specified event to occur, but never received it. The software has recovered and L2VPN forwarding should not be affected. This error will only occur on the active RP on startup or on the newly active RP after RP failover.), (Recommended Action: If L2VPN forwarding is not performing as expected, contact TAC with the log message.If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-3-REMOVE_GROUP_FAILED ### Response: (Severity: 3), (Category: IP), (Description: IPv4 was unable to remove membership to the group. Commonly, this is done for 224.0.0.1 by ipv4-ma with no associated socket when an interface is disabled, or for all groups (multicast promiscuous mode) whem multicast routing is disabled. It might be ok to ignore the failure.), (Recommended Action: shut/unshut of the interface will trigger leave/join respectively. Do as appropriate to recover. Collect the output of show tech-support, show ipv4 ma trace, show ipv4 trace, debug ipv4 ma mhost from the location the error message comes from. Note any previous errors related to multicast membership. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE0_LANE_CRC_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE0_LANE_CRC_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-UDI_AVAILABLE ### Response: (Severity: 6), (Category: SERVICES), (Description: 'Unique device identification number is ' 'available on the device'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_MA_PWHE-3-REPLICATION_SUCCESSFUL ### Response: (Severity: 3), (Category: L2), (Description: The interface mentioned in the message has been successfully replicated, and recovered from previous failed attempt.), (Recommended Action: No further user action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to enable RSVP on all interfaces? ### Response: To enable RSVP on all interfaces, use the 'mpls traffic-eng interface all' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#mpls traffic-eng interface all <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-7-CLIENT_MONITOR ### Response: (Severity: 7), (Category: HA), (Description: The wdsysmon server returned an error to a client in response to a request to remonitor an event manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNVGEN-3-ERR_SYSDB_BIND ### Response: (Severity: 3), (Category: MGBL), (Description: 'Unable to bind to sysdb. The error is displyed in the error message.'), (Recommended Action: Collect the following logs and contact your technical support representative for assistance. a) Console logs b) show tech-support parser c) show tech-support sysdb) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-SHUTDOWN_CHECK_FAILED ### Response: (Severity: 4), (Category: L2), (Description: A Frequency Synchronization process could not determine whether all Frequency Synchronization configuration has been removed and so cannot exit safetly. Frequency Synchronization processes may be running despite no Frequency Synchronization configuration existing.), (Recommended Action: No action is required. If the message continues to be seen, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDP-3-NSR_ACK_CHK_FAILED ### Response: (Severity: 3), (Category: ROUTING), (Description: NSR ACK check failed. Please perform show mem heap for analysis.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_METRO-3-QINQ_TCAM_WRITE_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: L2FIB Metro L3 QinQ entries programming in TCAM failed. The hardware and software entries will be out of sync.), (Recommended Action: Collect L2FIB debugs/traces and report to crs-l2vpn-dev team. -show tech l2vpn -show l2vpn platform trace all all location <> -show running-config -show l2vpn forwarding hardware ingress detail location<> -show l2vpn forwarding hardware egress detail location<>) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMC-7-RESTRICTED_REGISTRATION ### Response: (Severity: 7), (Category: SYSDB), (Description: SysDB registration support from LC to shared and admin planes has been deprecated (but is still supported). This system message indicates the application that is still using this deprecated service.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_NAME_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: An unexpected error occurred looking up an interface's name from it's handle. The error code should provide an indication of what the problem is. The most likely explanation is that the interface with the specified handle no longer exists although the message may be caused by low memory conditions or an internal programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-EBS_CPU_DATA_MBE ### Response: (Severity: 1), (Category: PLATFORM), (Description: EBS to CPU packet data multiple bits error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GDOI-5-SVC_NOTICE ### Response: (Severity: 5), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-INTF_SESSION_UP ### Response: (Severity: 6), (Category: L2), (Description: The OAM session has been fully established, and regular heartbeat messages are being sent and received.), (Recommended Action: None. This is an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLKCTRL_T-3-PLL_PTP_STATE_FREERUN ### Response: (Severity: 3), (Category: PLATFORM), (Description: No external reference frequency is available for synchronization, so the PTP PLL output is free-running.), (Recommended Action: None. This is just a status indication.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD_MRIB-3-IFH_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: This message indicates an error is binding to the ifh server or obtaining the correct interface from the ifh server.), (Recommended Action: Execute 'show interfaces' to check all the interfaces are correctly defined. Copy the error message exactly as it appears on the console or in the system log. Issue the show mrib trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show mrib trace error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-3-GEN_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: A general error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-4-CARD_POST_NOT_AVAILABLE ### Response: (Severity: 4), (Category: PLATFORM), (Description: The card is reloaded due to a faulty HW/ASIC. The check on Online Diags indicates there is no diagnostic test available on the falling device, hence the card will then be reloaded with XR image.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-3-ERR_DETAILS ### Response: (Severity: 3), (Category: SECURITY), (Description: Client address, error, error description.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SVII_ADJ_LIB-3-ADJ_DATA_CORRUPT ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Either the active or standby Service State Controller for the location given in the message provided the Adjacency Manager with corrupt data. This most likely indicates a bug in the Service State Controller logic. No adjacencies will be installed for the named service, so no traffic will be forwarded to or from it.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSPP_REX-3-INIT ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of the RSPP REX library. This is used to divert packets, e.g. to a virtual firewall.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-5-NOT ### Response: (Severity: 5), (Category: OS), (Description: A NOTICE level message was emitted by QNET.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-FORMAT_NVRAM_LOW_MEM ### Response: (Severity: 3), (Category: MEDIA), (Description: Could not get enough memory to format NVRAM.), (Recommended Action: 'Router running low in memory. Reboot if possible.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_HQ_FULL_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue full error on XAUI 0 HQ on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEPKI-3-KEYSTORE_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: CEPKI failed to write the keys in persistent storage.), (Recommended Action: 'Regenerate the key which failed to get stored in persistent storage') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDDRV-6-FABRIC_PING_SUCCESS ### Response: (Severity: 6), (Category: PLATFORM), (Description: The DRP connection through ethernet failed, however the connection through fabric was succesful. recommended_action: *NONE*), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_TCAM_RM-6-LOW_WATER_MARK ### Response: (Severity: 6), (Category: L2), (Description: The TCAM device has sufficient number of free cells left.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_PROC_READY ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS failed on a call to system manager to indicate that it's ready to proceed. It's an internal fatal error. IS-IS process will abort.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-3-NO_PRIV_MSG_HANDLER ### Response: (Severity: 3), (Category: OS), (Description: --), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_VPLS-3-GCS_MAC_INSTALL_QUEUE_STALLED ### Response: (Severity: 3), (Category: PLATFORM), (Description: MAC install queue stalled.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_LIST_ADD ### Response: (Severity: 3), (Category: ROUTING), (Description: A process has requested information through SysDB, probably as the result of executing a show command. The attempt to add an item to an external data manager list has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-4-OVERTEMP_COND_CLEARED ### Response: (Severity: 4), (Category: DRIVER), (Description: When the ambient temperature return back to valid operational range, then the CCC FPGA will power on the board to bring it back to operational state.), (Recommended Action: N/A.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-2-ENFORCE_GRACE_EXPIRED ### Response: (Severity: 2), (Category: LICENSE), (Description: The licensed feature is still enabled after grace period.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-OPERATION_COMPLETED_WITH_ERRORS ### Response: (Severity: 3), (Category: INFRA), (Description: Specified install operation in the error message completed but with errors.), (Recommended Action: The reason for this install operation failure has to be analyzed. Check the install operation log by 'show install log ' id is same as displayed in the syslog message which will be helpful to understand the reason for the install operation failure. Collect the show tech logs by running 'show tech-support install' and forward the logs to the TAC. Provide the details about any relevant system events/operations before this failure.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-UNEXPECTED_SCRIPT_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The execution of the indicated script has been exited due to reception of the indicated signal.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-2-LOG_CRIT ### Response: (Severity: 2), (Category: OS), (Description: A Critical message logged.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSLOG-7-MISC_ERR ### Response: (Severity: 7), (Category: OS), (Description: An unexpected error occurred. This can happen when the process is (re)starting. The process recovers by restarting itself.), (Recommended Action: Collect the output of show tech-support, show processes , show memory and show watchdog memory-state from the location the error message comes from. If the error message doesn't persist, it can be ignored. If the error message persists,call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the ASR9K platform FIB specific code software to indicate anomolies that are not FATAL. This error is most likely caused by a temporary situation, so is unlikely to re-occur.), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace all loc ). Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BACKUPSSHD-6-INFO_SUCCESS_COMMAND ### Response: (Severity: 6), (Category: SECURITY), (Description: The sshd successful login information.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBMA-6-SVC_INFO ### Response: (Severity: 6), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_COMM_DRVR-7-ERR_LTRACE_INIT ### Response: (Severity: 7), (Category: FABRIC), (Description: The SFE common infra driver could not open the ltrace buffer. The SFE common infra driver and the system should function as normal, with the exception that ltrace will not be available for sfe_drvr process.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-LOW_IN_MEM_CORR_ECC_ERROR_LNK2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast input memory correctable ECC error on link 2), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FPD_BURNER-5-version ### Response: (Severity: 5), (Category: PLATFORM), (Description: Invalid FPD version to RP console.), (Recommended Action: No action is required..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: iosxrwbd-1-RESTART_NOT_SUPPORTED ### Response: (Severity: 1), (Category: PLATFORM), (Description: This is an error message in the DPA module to indicate that a process that doesn't support restart has been restarted (crash, CLI or SMU installation) Process will trigger node reload to recover after collecting required information in the linecard's disk), (Recommended Action: Please collect the core file and DPA traces from linecard's disk Ignore this if process was operationally restarted like process restart command or process restart SMU installation those operations are not supported yet and nothing to debug at this point) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-MPLS_REPLAY_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: Serivce layer failed to replay MPLS objects to Label Switching Database.), (Recommended Action: The Forwarding Information Base may be inconsistent. Controller/agent may initiate a recovery action by unregistering MPLS and replay a new Forwarding Information Base. This error may occur on process restarts if MPLS objects cannot be played back to Label Switching Database.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are some basic functions an operating system must provide to support networking? ### Response: A network operating system must provide process scheduling, interrupt handling, memory management and protection, inter-process communication (IPC), synchronization services, and common shared libraries. It needs preemptive multitasking and multithreading with memory protection for processes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSI_AGENT-3-INIT_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: Initialization of a required module failed. The process was unable to continue.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-TYP_TX_RX_TIMEOUT ### Response: (Severity: 2), (Category: PLATFORM), (Description: Device driver detected a timeout on some bus), (Recommended Action: Please try to correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DAD-3-EVM_ASYNC_ATTACH_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: A failure occured while trying to setup the event listen structure for package un-installs.), (Recommended Action: Check whether policy_repository process is running properly by command 'show process policy_repository' Check the install logs if all the packages are downloaded and install operations completed properly) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DRP_PAIRING_CLIENT-7-ERR_DLL_INIT ### Response: (Severity: 7), (Category: PLATFORM), (Description: This message indicates that during dra_pairing dll attach, either debugging or ltrace services cannot be initialized.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX8508-2-HW_STRAP_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: PCIE device hardware strap error), (Recommended Action: Please reload the board using the following command: If the issue persists please, contact your technical support representative with the gathered information. 'reload location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-3-ADD_GROUP_FAILED ### Response: (Severity: 3), (Category: IP), (Description: IPv4 was unable to add membership to the group. Commonly, this is done for 224.0.0.1 by ipv4-ma with no associated socket when an interface is enabled, or for all groups (multicast promiscuous mode) whem multicast routing is enabled. Failure might result in issues in multicast host functionality or multicast fwding functionality.), (Recommended Action: shut/unshut of the interface will trigger leave/join respectively. This can be done to retry the group join. Note any previous errors related to multicast) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-2-ASIC_ENUM_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Crossbar driver detected error during ASIC enumeration.), (Recommended Action: Driver will reload the card to recover from error. If the message occurs during every power cycle then please contact tech-support. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-BMP_SAMEHOSTPORT ### Response: (Severity: 4), (Category: ROUTING), (Description: This message indicates that another BMP server has been already configured with same host and port combination.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_DIAG-3-SCRATCH_REG_FAILURE ### Response: (Severity: 3), (Category: DIAG), (Description: The diagnostic test for LC scrach register has detected an error and if reload/shutdown thresholds are set corresponding action will be taken by the diagnostic software on failure.), (Recommended Action: Collect the console error messages exactly as it appears on the console and call cisco support engineers with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_PIDB-4-WARN ### Response: (Severity: 4), (Category: PLATFORM), (Description: A run time warning occurred during the pidb operation on the linecard. The reason for the error is dispalyed. Please call Cisco Support with the error information), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-6-UPD_FILTER_MSG_BUFFERS_RESIZE ### Response: (Severity: 6), (Category: ROUTING), (Description: Currently resizing of update filter message buffers is not supported.), (Recommended Action: Configure update filter message buffer size before the session comes up.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-UNSUPPORTED_BOARD ### Response: (Severity: 3), (Category: PLATFORM), (Description: This indicates that the indicated board type is not supported by the current IOS XR release and it will be powered down.), (Recommended Action: Check the data sheet of the board for minimum required IOS XR version.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INFRA_TEST-7-SOLICITED_A ### Response: (Severity: 7), (Category: TEST), (Description: A solicited message with a string arg and an integer arg and an interface.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP0_INTR_SLICE5_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP0_INTR_SLICE5_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-4-OPTICS_FAILURE ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message provides information about the fault occurred on the interface.), (Recommended Action: The message is just for information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_SE-3-MALLOC_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The message indicates malloc failure while allocating block.), (Recommended Action: Reduce other system activity to ease memory demands, then restart the process. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XCVR-3-FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is a failure message from the XCVR which indicates default xcvr notification other than the notifications like removed, ready, failed, presence_even_ack), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-3-STALE_SESSION ### Response: (Severity: 3), (Category: SECURITY), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-4-SEND_HELLO_PDU_TO_ISIS_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: CLNS was not able to send a hello class PDU to ISIS. This could be because of communication problems between CLNS and ISIS.), (Recommended Action: If this message is seen during transient conditions, for example when ISIS is restarting either because of install operation OR because ISIS crashed then it is not harmful. If the error message says out of memory, it is because of the queue between CLNS and ISIS being FULL which could either be because traffic rate is very high or ISIS might not be reading the packets. If it is seen under steady state conditions OR adjacency flaps are seen on this interface or re-occur then contact cisco-support. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-4-DUMPER_SNAP_DUMP ### Response: (Severity: 4), (Category: OS), (Description: A non-invasive voluntary coredump requested by the process. Process might be experiancing a condition which needs investigation. This core file will help analysing the issue.), (Recommended Action: This should not occur in normal conditions, please provide the coredump to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_SERVER-6-EXIT ### Response: (Severity: 6), (Category: L2), (Description: ASIC scan server exits, expected behavior.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-4-CLI_MSG_ERROR ### Response: (Severity: 4), (Category: OS), (Description: The message received by the server had inconsistent values.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_0_LOSS_OF_SYNC_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Loss of sync on NPU-0 interface on bridge instance-1.), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-4-MRIB_WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: An problem communicating with the mrib.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show mrib trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show mrib trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show msdp trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show msdp trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging processes msdp command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging processes msdp output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: 10GE_PLIM-2-UNSUP ### Response: (Severity: 2), (Category: L2), (Description: This PLIM is a prototype and is not longer supported), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIMGR-3-MUTEX_UNLOCK_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The mutex unlock for register operation returned error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIRD-3-INV_DEBUG_FLTR ### Response: (Severity: 3), (Category: L2), (Description: The PIRD debug library was notified about the creation of a debug item in SysDB which had an unexpected number of filter parameters. The corresponding debugging flag has not been enabled in PIRD, which may lead to some debug not being printed as expected.), (Recommended Action: If any problems are observed, then try removing the debug filter using the 'no debug pird' command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_SOCKET-2-EVM_ERR_INIT ### Response: (Severity: 2), (Category: L2), (Description: The initialization of socket with event manager failed due to some reason. The argument depicts the reason of the failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the error is during the initialization, restart the process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-WARN_CIDRID_SES_THRESHOLD_EXCEED ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The number of PPPoE sessions on a particular Circuit ID and Remote ID has exceeded the configured threshold.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_SYSDB ### Response: (Severity: 4), (Category: L2), (Description: SSRP encountered an error using the SysDB service. The error message describes what operation has failed and why it failed. The most likely reason for this is a connection problem with the SysDB server, but the error could also be caused by low memory resources or programming error.), (Recommended Action: Consider restarting the PPP MA process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-4-CMRPL_UNLOCK_FAILED ### Response: (Severity: 4), (Category: SYSDB), (Description: When commit replace command is executed, it creates a item in SysDB which can be thought of as a lock. Once commit replace finishes, the lock item should be deleted so that further such commit replace operations can continue. If for some reason this lock item cannot be deleted, it can cause any further commit replace operations to be rejected.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-7-CLIENT_UNMONITOR ### Response: (Severity: 7), (Category: HA), (Description: The wdsysmon server returned an error to a client in response to a request to stop monitoring an event manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA-6-PM_ERR ### Response: (Severity: 6), (Category: L2), (Description: This is an error condition which should not occur in normal conditions. %d - indicates the bay number), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-CONTEXT_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAP_LISTEN-3-BAG_RELATED_FAILURE ### Response: (Severity: 3), (Category: ROUTING), (Description: This error can occur only when the SAP had a problem in registering for SAP bags for multicast from SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show sap trace command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show sap trace output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show logging processes sap_listen error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging processes sap_listen error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show context command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show context output, call your Cisco technical support representative and provide the representative with the gathered information. from the node obtained from the above command, run the following command: Copy the error message exactly as it appears on the console or in the system log. Issue the show sysdb trace edm command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show sysdb trace edm output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TELNETD-7-THREAD_CREATE ### Response: (Severity: 7), (Category: IP), (Description: In a telnetd session. The vty thread creation failed .Internal error.), (Recommended Action: Internal error. Restart telnetd process to overcome.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-DRAM_BUFFER_DEL_INTR ### Response: (Severity: 3), (Category: FABRIC), (Description: Continuous dram crc errors seen. The dram might have gone bad. If the problem does not get resolved after auto-reload of the card, consider replacing the dram card.), (Recommended Action: Contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: USB-2-DEV_HUB_TIMEOUT ### Response: (Severity: 2), (Category: PLATFORM), (Description: USB Hub transaction is taking excess time.), (Recommended Action: The USB hub requires immediate service. Please attempt to restart the hd_drv process using command: 'process restart umass-enum'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an L2VPN bridge domain backup pseudowire? ### Response: To configure a backup pseudowire for an L2VPN bridge domain, use the 'backup peer' command within the bridge-domain configuration. l2vpn bridge-domain BD1 neighbor 10.1.1.3 backup peer 10.1.1.4 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'show logging' command in Cisco IOS XR? ### Response: The 'show logging' command in Cisco IOS XR is used to display the contents of the logging buffer. It shows the logged messages, including the severity level, timestamp, and message text, which can be useful for troubleshooting and analysis. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_0_MGT_CV_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-0 MGT code violation on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN_SVR-3-MMAP_SHM_FAIL ### Response: (Severity: 3), (Category: OS), (Description: mmap of the shared memory required to store servers tree nodes failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture 'show shmwin summary', 'show shmwin trace server', and 'show shmwin trace all'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-7-CLINFO_UNHOLD ### Response: (Severity: 7), (Category: HA), (Description: An internal error was detected when trying to decrement the hold count of the client info data of a synchronous message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-TUPLE_MISSING ### Response: (Severity: 3), (Category: OS), (Description: Tuple missing from table.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support sysdb command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support sysdb output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCM-2-IM_ERR ### Response: (Severity: 2), (Category: L2), (Description: Error in IM(Interface Manager) operation first %s - Failure second %s - reason for the failure This happens on the LC with ATM interfaces), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Either caps addition or removal failed. Depending on the failure, reapply the configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_BMADJ-6-INFO_STR ### Response: (Severity: 6), (Category: PLATFORM), (Description: PLATFORM BMADJ, Information), (Recommended Action: The message is just for debugging only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_RIB-6-INFO_RT_HDR_NOTUSED ### Response: (Severity: 6), (Category: ROUTING), (Description: The RIB batching API believes that it already has this router header in the batching buffer.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CVAC-4-FILE_IGNORED ### Response: (Severity: 4), (Category: MGBL), (Description: CVAC (Cisco Virtual Appliance Configuration) ignored a configuration file and did not apply it to the router. The specified reason explains why the file was ignored.), (Recommended Action: Determine whether the configuration file should have been applied to the router. (In some cases a file may be ignored due to intentional redundancy between files.) If the file should not have been ignored, make whatever changes are needed to address the reason for ignoring the file, and issue the 'reload' command to cause CVAC to run again after the router reloads.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_PM-3-INDEX_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The error indicates the mismatch between the egress and ingress interface.), (Recommended Action: No action is required as the software should be able to recover from this error. Please collect 'show log location ' output, and 'show memory summary location from that location.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPIO_PD-3-EA_DEBUG_INIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Debug initialization failed in packet programming path. Packet path initialization is aborted and may be retried.), (Recommended Action: Restart the protocol process. 'process restart location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-3-UNHANDLED_DEBUG_OPTION ### Response: (Severity: 3), (Category: HA), (Description: The debug option chosen is not handled.), (Recommended Action: Make sure that the debug option chosen is the right one.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure LDP session capabilities? ### Response: To configure LDP session capabilities, use the 'capabilities' command under the MPLS LDP configuration. RP/0/RSP0/CPU0:router(config)#mpls ldp RP/0/RSP0/CPU0:router(config-ldp)#capabilities sent <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIAAPI-3-INVALID_PARM_DEVICE_INSERT ### Response: (Severity: 3), (Category: MEDIA), (Description: An invalid parameter value was passed to media driver when a media device is inserted), (Recommended Action: Report this message to TAC. Capture console log, 'show media' and 'show media trace' output.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DWDM-6-SET_WAVELENGTH ### Response: (Severity: 6), (Category: L2), (Description: DWDM Controller has provisioned optics to [HW Default | Configured | GMPLS Signaled] wavelength.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Attached bit in IS-IS? ### Response: The Attached bit is set by Level 1/Level 2 routers in their Level 1 LSPs. It indicates that the router is attached to the Level 2 backbone. This information is used by Level 1 routers to determine the closest Level 1/Level 2 router for reaching destinations outside the area. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-4-INPUT_PROGRAMMING_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The Frequency Synchronization manager that generated the message failed to program the inputs for the specified selection point into the platform. Any changes to the inputs (for example, if an input is no longer available or if it's QL has changed) will not take effect.), (Recommended Action: If the error message indicates an out-of-resource condition, then resolve the underlying resource issue, and restart the Frequency Synchronization manager on the affected node using the following command: process restart fsyncmgr location Otherwise, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_BRIDGING-7-SETTING_NONFREE_MAC_OFFSET_ERROR ### Response: (Severity: 7), (Category: PLATFORM), (Description: MAC offset currently being set is already in use), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INVENTORY_PARSER-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that a failure has occured in Inventory parser, but there is not corresponding error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-3-BADPAK ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Consistency check detected corruption in the specified area of the specified packet. This will cause packet manager to restart. Please report the message and value to your technical support representative.), (Recommended Action: Please collect a core dump of the process from which the message is output, using the 'dumpcore running' command to catch the current packet memory state ('exception pakmem on' must also be configured). Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMC-7-ERROR_RINFO ### Response: (Severity: 7), (Category: SYSDB), (Description: A request error due to gsp error during SYSDB MC waited the expected number of replies. Then SYSDB MC would take recovery process), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU-3-PLAT_LOCAL_COMM_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: The reporting process has been unable to obtain information on the local node from the Platform Local service. This suggests that there is an issue with that service, or the connection to it.), (Recommended Action: The process will restart itself in an attempt to recover. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-3-FWC_SSC_UPDATE_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: The Firewall Controller's attempt to inform the Service Director of a change to either interface/firewall state has failed. This will have left the system in an inconsistent state.), (Recommended Action: Restart the Firewall Controller process using the 'process restart' mechanism.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-PSS_ERR ### Response: (Severity: 3), (Category: OS), (Description: Persistent Storage Service handling error.), (Recommended Action: Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSYSDB-7-INTERNAL ### Response: (Severity: 7), (Category: SYSDB), (Description: The client library has either failed a function that expected to succeed, or has got into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCC-3-FPGA_PCI_PERSISTENT_FAIL ### Response: (Severity: 3), (Category: DRIVER), (Description: CCC driver was unable to recover from the PCI link failure due to a PCI FATAL erorr. CCC driver has to be restarted to recover. If 5 restarts of the driver cannot recover the card will reload. If card reload cannot fix the problem it is a HW fault where something went wrong with the PCI bridge), (Recommended Action: RMA) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PREIFIB-4-BATCHING ### Response: (Severity: 4), (Category: OS), (Description: Hardware pre-ifib returned an error during a batching operation.), (Recommended Action: Restarting pifibm_server_lc and pifibm_server_rp may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SM-3-UNABLE_TO_PROCEED ### Response: (Severity: 3), (Category: INSTALL), (Description: This self-managing component encountered an expected error when attempting to carry out an action required for the currently requested operation, so has had to halt processing of the operation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_13_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_13 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GNSS-4-INIT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: An error was encountered while the specified process was initializing. The error message contains details about the source of the error.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PWRMON-2-MODULE_FAIL_REASON ### Response: (Severity: 2), (Category: PLATFORM), (Description: 'Some power module failure condition has been raised.'), (Recommended Action: Try restarting the using CLI command in exec mode - process restart pwr_mgmt If the error exists try -insert and re-insert the PM If the error exists - Replace the power module) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PA-4-FM_MSG_TIMEOUT ### Response: (Severity: 4), (Category: OS), (Description: The PA failed to receive a response to an IFIB table update or an IFIB slice assignment update message.), (Recommended Action: Restarting lpts_pa and lpts_fm on the node were the issue is seen may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-4-SELECT_IGNORED ### Response: (Severity: 4), (Category: ROUTING), (Description: Internal notification error.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_4P_OC192-3-ERR ### Response: (Severity: 3), (Category: L2), (Description: fail to init debug service event manager fails to provide its service), (Recommended Action: sysmgr will respawn plim_4p_oc192 'show logging' to look for the errors from event manager) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-MIB_TRAP_NFN_FAILED ### Response: (Severity: 4), (Category: L2), (Description: PTP was unable to perform a MIB notification for one of its configured traps. A MIB client listening may have missed a notification.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'backup disable' command in IOS XR MPLS TE configuration? ### Response: The 'backup disable' command is used under an MPLS TE tunnel interface to disable the use of that tunnel as a backup tunnel. By default, all TE tunnels are eligible to be used as backup tunnels for FRR protection. This command allows you to exclude specific tunnels from being used as backup, which can be useful for controlling the backup path selection. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR support external AAA for user authentication? ### Response: Cisco IOS XR supports external Authentication, Authorization and Accounting (AAA) using TACACS+ and RADIUS protocols. The router can be configured to authenticate users against an external AAA server. This allows centralized management of user credentials. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RIB-3-ERR_DELETE ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occured when trying to delete a path from a route.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_10_LOW_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-4-DEPRECATED_RTRID ### Response: (Severity: 4), (Category: ROUTING), (Description: OSPFv3 router-id has been deprecated.), (Recommended Action: Use router-id .) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-EPE_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred while initializing the BGP EPE process. If this occurred during process startup or RP Switchover, then the process may be restarted.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCIE-4-ROOT_DEVICE_BUS_WARNING_THRESHOLD_EXCEEDED ### Response: (Severity: 4), (Category: PLATFORM), (Description: A root device has been detecting a PCIe bus error and it is exceeding threshold. The message has the device identification, error severity, and error type.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERROR_HW_LIMIT_RT ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, error), (Recommended Action: Change the config to adhere with the supported limit.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LDA-4-MAP_EP_SHMEM_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: Failed to map the MPA's shared memory. The error message describes the Software warning.), (Recommended Action: Please try to recover by doing the process restart of the process that generated the error.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-3-ISSU_GROUP_COUNT ### Response: (Severity: 3), (Category: INSTALL), (Description: Issu process failed while getting group members count of a group message. ISSU operation will continue without any error. This will be attempted again after some time.), (Recommended Action: ISSU manager will retry after sometime to fetch the value. If the issue persists even after tries, contact tac with 'show tech-support issu'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBMA-1-SVC_ALERT ### Response: (Severity: 1), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-NETIO_IDB_UNAVAILABLE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: While processing an ingress packet, the eint driver failed to find netio idb), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does SysDB collaborate with Configuration Manager in IOS XR? ### Response: SysDB collaborates with Configuration Manager in IOS XR by storing the configuration data and notifying relevant processes when configuration changes occur. Processes can register with SysDB to be notified of specific configuration changes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EGRESSQ_HW_DLL-3-SBE_THRESHOLD_EXCEED ### Response: (Severity: 3), (Category: L2), (Description: Egressq SBE rate has exceeded the configured high threshold value. This is a self healing error condition.), (Recommended Action: No action is required. It is a self healing error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ_MGR-4-ERR_CHKPT_INIT ### Response: (Severity: 4), (Category: FABRIC), (Description: Fabricq Checkpoint Init error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INBAR_HB-7-ERR_HEARTBEAT_FSM_STATE ### Response: (Severity: 7), (Category: FABRIC), (Description: Fabric server heartbeat monitoring mechanism detected a problem in the internal state machine.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-3-ERR_SYSDB_CONNECT ### Response: (Severity: 3), (Category: ROUTING), (Description: The process failed to bind to system database while opening a connection to it.), (Recommended Action: Restart of EIGRP might solve the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_EDM-3-SYSDB_EDM_REG_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: The process failed when attempting to register its external data manager with SysDB.), (Recommended Action: restart policy_repository and check for re-occurence of issue) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_PA_FF-3-EVENT_UPDATE_FAIL ### Response: (Severity: 3), (Category: OS), (Description: An error was detected when initializing the event queue between two infrastructure module.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ET1_INTR_CRC16_CHK_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ET1_INTR_CRC16_CHK_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-CLOCK_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: Clock Failure to SFE ASIC's- Core pll clk or serdes pll clk failure), (Recommended Action: Recovery action is taken. FC reload if all FE asic's clk failure. Else PON on specific FE asic. CLK failure can be because of core pll or serdes pll and issue is identifeid by reading the CLK PLL register. If the CLK is not recovered after with several reloads, then the FC card will be shutdown.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-4-INVALID_DEVICE ### Response: (Severity: 4), (Category: DIAG), (Description: A diagnostic request is being made on a device that does not exist.), (Recommended Action: Ensure that the specified device number (1-based) exists and is valid.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MCAST_CHKPT-3-ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-3-LANE_2_LOW_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a QSFP+ laser bias less than or equal to the low laser bias warning threshold. The QSFP+ is the pluggable optics on the line cards. The laser bias threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: gsp-4-ETH_BUILDUP ### Response: (Severity: 4), (Category: OS), (Description: GSP Ethernet queue buildup indicates underlying transportor hardware issue), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-7-FAIL_MEM_ALLOC ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failure in Inventory Manager memory allocation. No sufficient memory), (Recommended Action: No action needed. Inventory Manager process will exit automatically) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-LWA_ADD_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to enable this user to log into ksh.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-DELETE ### Response: (Severity: 4), (Category: MGBL), (Description: An error occurred invoking an MDA function. This could be because the object does not exist. The details are in the error string.), (Recommended Action: Check that the object to delete exists. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-TSP_B_PKT_LTH_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: TSP decoder B length error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SAM-4-WARNING_CA_CERTIFICATE_EXPIRED ### Response: (Severity: 4), (Category: SECURITY), (Description: SAM found the expired CA certificate in table had been accepted by user.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-4-WB_SERIAL_NUM_TRUNCATE ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISTRIB_LIB-6-GROUP_SEQ_INFO ### Response: (Severity: 6), (Category: OS), (Description: Just more information.), (Recommended Action: 'No action is required.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-MSG_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Error encountered while handling messages received by acctd.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_BULK_NUM_OPS ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. This could be because the operation does not exist. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_AGT-3-INVALID_PARAM ### Response: (Severity: 3), (Category: INFRA), (Description: ISSU Agent received an invalid operation ID from Install Manager, suggesting an inconsitency. ISSU Agent will veto send a veto message to Install Manager in order to abort the operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-3-CPU_THERMAL_SHUT ### Response: (Severity: 3), (Category: PLATFORM), (Description: TBD.), (Recommended Action: Please collect the output of 'show logging' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAGS-2-SRSP_ACTIVE_EOBC_MCAST_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Standby RSP failed to transmit heartbeat to all nodes via active EOBC links.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMHAD-4-ERR_NOMEM_WARNING ### Response: (Severity: 4), (Category: OS), (Description: The Platform Manager HA Driver DLL was unable to add one new fault record due to lack of memory, but it is still running.), (Recommended Action: Add more memory to the card specified in the System Message. If the this message recurs after a memory upgrade, copy the System Message text exactly as it appears on the console or in the system log, and contact your Cisco technical support representative, and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MIRROR-3-ERR_BAG_REGISTER ### Response: (Severity: 3), (Category: MGBL), (Description: 'Failed to register edm bags'), (Recommended Action: Collect the following details: 1. Command issued 2. show mirror trace. 3. console logs. 4. If config is restored from file, then filename/contents. 5.If command failed at startup, show config trace and show config failed startup.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MA-3-SYSDB_REG_NOTIFY_FAILED ### Response: (Severity: 3), (Category: IP), (Description: IPv4 Management Agent encountered failure in registering notifiee with SysDB. It will recover itself by restarting. Typically this error is caused if sysdb is unavailable for an extended period.), (Recommended Action: If the problem persists get the output of show processes, show sysdb trace, show sysdb trace clientlib job , show ipv4 ma trace location <>, debug sysdb notification job from the location the error message comes from.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-REP_COM_REMOVE_PENDING ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that install remove inactive all will be triggered post commit if install commit is successful), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-SHUTDOWN_ON_MULTIPLE_UNGRACEFUL_RELOAD ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that the node has already undergone mutilple ungraceful reboots in last one hour or one day and has reached node's hourly or daily reboot threshold limit of 5 (in last one hour) or 8 (in last one day). In order to avoid further disruptions to the netwrok due to this node, its better to shut (power) down this node.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-5-POLICY_RESET ### Response: (Severity: 5), (Category: ROUTING), (Description: Automatic soft reset on policy change is not possible as the neighbor does not support ROUTE_REFRESH and 'soft-reconfiguration inbound' is not configured.), (Recommended Action: Manually clear affected peer at earliest convenience, in order for policy change to take effect.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-ERR_GENERAL ### Response: (Severity: 3), (Category: MGBL), (Description: 'Hit general error. The error is displayed in the error message.'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TEMPERATURE_ALARM-3-DIE_OVERTEMP_T4_MAJOR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Hotspot temperature sensor is risen above or fallen below T4 threshold(pfm major temp. threshold).), (Recommended Action: *SH_CMD show env*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-FAILED_EOI ### Response: (Severity: 3), (Category: OS), (Description: Process failed to send EOI and exited.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPUCTRL_SIP700_DLL-3-TRACE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: The CPU Control, Dynamic Link Library (DLL) failed to initialize the LTrace facility. The effect is that the CPU Control debug trace facility is not functional. This means that trace information used by Cisco support to help isolate CPU Control device issues may not be available. This does not impact normal CPU Control device operations. Note that it is unlikely that this failure would occur by itself. This failure is generally indicative of a larger LC-wide problem. %s - description of the specific failure encountered %s - error detail, if appropriate), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_EDM_REGISTER ### Response: (Severity: 3), (Category: ROUTING), (Description: The process could not register with SysDB for management of the data used by IS-IS statistics and management agents. As a result, isis show and clear commands will not function.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_18 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB-6-STORM_CONTROL ### Response: (Severity: 6), (Category: PLATFORM), (Description: Storm control can only applied on main port. Multiple configurations on sub-interfaces under the same main port are not supported.), (Recommended Action: User needs to remove storm control on all main ports indicated in ios-msg before re-applying the desired storm control configuration to a single interface) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-NPU_0_FC_DIP2_ERR_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress flow control DIP2 parity error on NPU-0 interface on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_INARP-4-UNKNOWN_MSG ### Response: (Severity: 4), (Category: L2), (Description: An unknown InARP message was received - it will be ignored. This is just an information mentioning the InARP message arrived is not of request or response type.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BANNER-3-SYSMGR_CALL ### Response: (Severity: 3), (Category: OS), (Description: A software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONET_LOCAL-4-ALARM ### Response: (Severity: 4), (Category: L2), (Description: The specified SONET Alarm has been declared or released.), (Recommended Action: Recommended action is to repair the source of the alarm.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKS_SRVR_ENGINE-3-ERR_2SL_PARAM ### Response: (Severity: 3), (Category: SECURITY), (Description: SKS server exp error message.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PDMA_SPP-3-PKT_DROPPED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet dropped while injecting from the CPU of the affected card.), (Recommended Action: The issue might not be very significant if observed only once. Copy the error message exactly as it appears on the console or in the system log. Issue the show spp pdma trace all location command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show spp pdma trace all location output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFM-2-LIB_LC_RESET ### Response: (Severity: 2), (Category: PLATFORM), (Description: Platform Fault Manager DLL received an error from one of the LC devices. The LC MUST be reset.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-ISM_PD_LIB_SPA_SHUTDOWN ### Response: (Severity: 6), (Category: INSTALL), (Description: The shutdown operation is being performed on the indicated SPA when fabric plane upgrade fail.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_BASIC-3-ASSERT_MSG ### Response: (Severity: 3), (Category: HA), (Description: Checkpoint related internal data structures gone wrong. Checkpoint cannot continue further hence, process will crash and restart immediately after this message.), (Recommended Action: Please collect console logs during the crash, corefile and contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_RIB-3-ERR_ROUTE_HDR ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered in the call to ipv4_rib_batch_add_route.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOGIN_SHELL-6-DS_CONNECT_RETRY ### Response: (Severity: 6), (Category: MGMT), (Description: This comes when program fails to connect to directory service due to some infra issue, the program will re-connect the same), (Recommended Action: The program tries to re-connect the directory service, once directory service is up, this message will not come up, If directory service is up and still this message comes, the work-around would be restart program) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INTCTRL-2-PUNT_TX_PAR_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Interrupt controller FPGA reported that data it received from crossbar fabric arbiter had parity error), (Recommended Action: Please correct the problem by reloading the board using command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CSI_EA_PD-3-INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: This is an informational message in the CSI EA Platform to indicate that an error was seen during init operation. A return code is returned which can do a retry or exit based on if error persists.), (Recommended Action: Please collect the console log,) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install label command in IOS XR? ### Response: The 'install label' command is used to assign a label to a set of packages. This label can then be used in other install commands to refer to that specific set of packages, making it easier to manage and identify them. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABIO_HFR-3-ERR_QAD_NOTIF ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to get the qad notification of queue depth above or below watermark. This normally indicates there is some issues with the qad queue %p - QAD queue id), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FAB_PROXY-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: The fabric proxy failed to create an event manager during the initialization. The driver will be non-operational due to this error.), (Recommended Action: The Proxy will recover by restarting. Verify that the driver will recover following action by the FM. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TP_SW-6-OPENROAM_ADAPTOR_INSTALL_SUCCESS ### Response: (Severity: 6), (Category: PLATFORM), (Description: This message indicates that Openroadm adaptor is successfully installed), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER_SNAP-6-DUMP_OK ### Response: (Severity: 6), (Category: OS), (Description: A non-invasive voluntary coredump requested by the process completed successfully. Process might be experiancing a condition which needs investigation. This core file will help analysing the issue.), (Recommended Action: This should not occur in normal conditions, please provide the coredump to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_TX_WL_OUT_OF_RANGE ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-2-HFR_FIB_OOR_ROUTES_UNBLOCKED ### Response: (Severity: 2), (Category: PLATFORM), (Description: CEF on the node had earlier detected that the number of routes had exceeded prescribed limits and route updates to the hardware had been blocked. It has now been unblocked.), (Recommended Action: Make sure this situation does not repeat) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE auto-bandwidth adjustment threshold feature? ### Response: The MPLS TE auto-bandwidth adjustment threshold feature specifies the percentage difference between the current tunnel bandwidth and the measured output rate that triggers an auto-bandwidth adjustment. A lower threshold means auto-bandwidth adjusts the tunnel bandwidth more frequently, while a higher threshold means adjustments occur only for more significant rate changes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-3-GEN_INFO_ERR ### Response: (Severity: 3), (Category: L2), (Description: An internal software error occurred in L2FIB manager process. This could be due to an internal processing error or an illegal state has been detected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVRAM-3-FORMATERROR ### Response: (Severity: 3), (Category: MEDIA), (Description: Probably the NVRAM device has gone bad.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RUMP-3-ERR_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-SYSMGR_TROUBLE ### Response: (Severity: 7), (Category: INSTALL), (Description: SysMgr appears to have become unresponsive, potentially requiring operator intervention.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSCMEDIA-3-ERR_EVM ### Response: (Severity: 3), (Category: PLATFORM), (Description: DSC Media DLL has encounered the annunciated Event Manager error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LPTS_NPMB-6-PROCESS_INGRESS_BUFFHDR_FAILED ### Response: (Severity: 6), (Category: OS), (Description: Ingress buffer header of packet failed to extract.), (Recommended Action: Copy the error message exactly as it appears, and report it to your technical support representative. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBNOTIFY-7-INTERNAL_DATA_INCONSISTENCY ### Response: (Severity: 7), (Category: INSTALL), (Description: The Install infrastructure has encountered an unexpected state, and will not be able to continue operating successfully.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-GEN_ERR ### Response: (Severity: 3), (Category: L2), (Description: Some requested operation failed. The text of the message displays the failed operation with error code.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FDI-3-ERR_RCV_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: TLV headder/Message is corrupted. SW will ignore rest of the messages.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-2-USAGE ### Response: (Severity: 2), (Category: OS), (Description: Incorrect command line parameters were passed to the nrs server, and so it failed to start.), (Recommended Action: Check the startup arguments passed to nrs server. A default configuration will be used if no parameters are passed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSU-3-IDPROM_READ_FAILURE ### Response: (Severity: 3), (Category: LIBRARY), (Description: The PSU IDPROM can not be read.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-NAMESPACE_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: Nvgen server failed to build config namespaces from internal namespace module. This may result in failure to output the configuration in the intended order in show run command. Or in internal config backup.), (Recommended Action: Collect the show version, show logging, show nvgen trace output, show runnning output, show config history and show tech-support sysdb. Contact TAC representative with this information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAA-3-DLL_INIT_ERROR ### Response: (Severity: 3), (Category: SECURITY), (Description: Error encountered while initializing AAA client library DLL.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-3-SYSDB_ITEM_ERROR ### Response: (Severity: 3), (Category: HA), (Description: SysDB returned an error to LRd.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_UTIL-7-DEBUG_REGISTER ### Response: (Severity: 7), (Category: HA), (Description: Registration of debug services failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XML_TTY-7-INTERNAL ### Response: (Severity: 7), (Category: MGBL), (Description: An internal error has occurred in the XML TTY Agent. Some XML requests (over TTY) may not be able to complete correctly.), (Recommended Action: Retry the XML request that had the error. Transient conditions should have passed, and in all likelihood, this request will go through. If not, close this TTY session, and restart a new TTY session. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-LSPTOOBIG ### Response: (Severity: 4), (Category: ROUTING), (Description: L-LEVEL LSP LSP-ID size LSP-LENGTH bigger than interface INTERFACE-NAME MTU INTERFACE-MTR, LSP dropped. This system was unable to flood an LSP out INTERFACE-NAME because the interface MTU was too small. The LSP has not been transmitted on the interface.), (Recommended Action: Configure the routing area and the interfaces with a consistent MTU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: umass_enum-5-UNABLE_TO_ACCESS_EUSB ### Response: (Severity: 5), (Category: PLATFORM), (Description: Check if eUSB device is there. If it unable to access the eUSB device then this notice message will be printed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSI_MASTER-6-GENERAL_INFO ### Response: (Severity: 6), (Category: OS), (Description: Normal operation. Informational only.), (Recommended Action: No action needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-4-NOT_IN_LOOPBACK ### Response: (Severity: 4), (Category: L2), (Description: A requset has been made by the remote peer to stop Slave loopback mode. However, we are not currently in Slave loopback mode. This indicates that the remote peer is out of sync with our current state.), (Recommended Action: Start slave Loopback mode before attempting to stop it.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the instcmd process in IOS XR installation? ### Response: The instcmd process is the Install Manager CLI process. It provides the user interface for performing installation-related tasks and communicates the user requests to the instdir process. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP-4-WARN_THREAD ### Response: (Severity: 4), (Category: IP), (Description: ARP has failed to create a thread for the specified process. In this situation ARP restarts and this should resolve the problem.), (Recommended Action: Restarting the process may fix the issue. If the issue is seen repeatedly Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-4-MSG_RESEND_ERROR ### Response: (Severity: 4), (Category: OS), (Description: Failed in re-sending a message after onboard logging server process resart.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_EXEC-6-OPERATION_NOT_SUPPORTED ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-LPTS_ADD_BINDING ### Response: (Severity: 3), (Category: ROUTING), (Description: The clns process was unable to add a binding to LPTS. This is an internal error.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE fast reroute (FRR) feature? ### Response: The MPLS TE fast reroute (FRR) feature provides link and node protection for MPLS TE tunnels. It enables fast traffic recovery upon link or node failure by using pre-signaled backup tunnels that bypass the protected resource. FRR is enabled on a per-tunnel basis and activated when the primary tunnel fails. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure RSVP bandwidth on an interface? ### Response: To configure RSVP bandwidth on an interface, use the 'mpls traffic-eng bandwidth' command in interface configuration mode. RP/0/RSP0/CPU0:router(config-if)#mpls traffic-eng bandwidth 100000 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSFP_PLUS-2-HIGH_VOLTAGE_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected an QSFP+ voltage greater than or equal to the high voltage alarm threshold. The QSFP+ is the pluggable optics on the line cards. The voltage threshold values are read from the QSFP+.), (Recommended Action: Verify that the device is properly inserted. Check the 'show environment voltages'. If the system voltage is normal then replace the optics with working one (if any). If the system voltage is not normal, then make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment voltages'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-6-CARD_POWERUP ### Response: (Severity: 6), (Category: PLATFORM), (Description: The Shelf Manager component has requested powerup on a line card or secondary RSP.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MMAP_PEER-6-RECV ### Response: (Severity: 6), (Category: OS), (Description: Failed recv() for a domain socket.), (Recommended Action: This message is informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-ACP_IPSEC_TO_NBR_CREATED ### Response: (Severity: 6), (Category: SERVICES), (Description: 'Autonomic Network Control plane - IPSEC tunnel ' 'established to neighbor'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the nsf ietf command in IS-IS? ### Response: The nsf ietf command is used to enable IETF-standard Non-Stop Forwarding (NSF) for IS-IS. Like Cisco NSF, IETF NSF allows the router to continue forwarding traffic during a supervisor switchover or a software upgrade. However, it uses a different mechanism for synchronizing the database with neighboring routers after the switchover or upgrade. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-ERR_HW_THRESHOLD ### Response: (Severity: 4), (Category: L2), (Description: A hardware error is detected on the PLIM, and the error threshold has been crossed. Software will take action as described in the error message, if not none, to try to contain or recover from the error. The hardware error and the software recovery action will not impact traffic. Device: %s%s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Threshold of %s - the defined threshold for this error. Software action: %s - the action that software will take to try to contain or recover from the error. Recommended user action: %s - recommended action to the user. Possible values: 'none' 'replace XFP' 'PLEASE MANUAULLY RELOAD THE LC AT NEXT MAINTENANCE WINDOW'), (Recommended Action: Take the recommended user action as it is described in the error message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-PAK ### Response: (Severity: 3), (Category: ROUTING), (Description: An operation failed during packet handling.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TZ-3-PUF_MAGIC_LOOKUP_ERR ### Response: (Severity: 3), (Category: OS), (Description: This indicate a format error in timezone configuration file.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-MSG_RECV_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Failed to receive message from AIB while waiting ' 'for async messages.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists.' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-START_FAILED ### Response: (Severity: 3), (Category: OS), (Description: The named virtual service failed to start.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-MALLOC_FAILED ### Response: (Severity: 7), (Category: HA), (Description: A call to allocate memory failed.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-BIOS_BOOT_FAILED ### Response: (Severity: 3), (Category: PLATFORM), (Description: BIOS has failed to boot from the indicated card. The failure could be related to secure boot failure.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6_MA-7-INIT_FAILED ### Response: (Severity: 7), (Category: IP), (Description: The IPv6 MA process failed to init software. This can happen when the process is (re)starting and any basic infrastructure service required by the process is not available.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-6-RSI_TABLE_ID_FAIL ### Response: (Severity: 6), (Category: ROUTING), (Description: Failed to get rsi table id for the reason specified.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_4P_OC192-3-GET_NODEID_ERR ### Response: (Severity: 3), (Category: L2), (Description: PLIM driver failed to obtain either its node ID or extract rack/slot/instance information (having obtained the node ID).), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-ISSU_SAVE_TRACES_DONE ### Response: (Severity: 6), (Category: INSTALL), (Description: Saved traces to standby node before switching over the node), (Recommended Action: This message is just to report that debug data is saved.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_PERSIST_SPECIAL_HANDLE_THRESH ### Response: (Severity: 1), (Category: PLATFORM), (Description: ASIC errors have occured and been handled. Such errors have crossed threshold.), (Recommended Action: ASIC errors that need special handling have occured and exceed the threshold. The error condition has been handled *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-2-CRT ### Response: (Severity: 2), (Category: OS), (Description: A CRITICAL level message was emitted by QNET.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-BA_UNSPEC_FAIL_10 ### Response: (Severity: 3), (Category: IP), (Description: The LMA is interworking with a PGW for Mobile Local Loop mobility service and is expecting the PGW Subscriber Continuity VSE to be present in the PBU messages that it received via the PGW.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_9_LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature less than or equal to the low temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CPAK with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_13_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_ALIGN_ERROR_LANE_INDICATE_13 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ALARM_MGR-3-MEM_ALLOCATE_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Error due to memory allocation failure.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the common thread states in the IOS XR microkernel? ### Response: The common thread states are\n- Running: Thread is currently executing on CPU\n- Ready: Thread is ready to execute, waiting to be scheduled\n- Blocked: Thread is waiting for an event (message, I/O, timer)\n- Receive blocked: Waiting for a message\n- Reply blocked: Waiting to reply to a message\n- Interrupt blocked: Waiting for an interrupt\n- Mutex blocked: Waiting for a mutex\n- Stopped: Thread is suspended and will not be scheduled\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_BAD_MAX_AREA_ADDR ### Response: (Severity: 4), (Category: ROUTING), (Description: Bad max area addresses (MAX-AREA-ADDRESSES, should be 0 or EXPECTED-MAX) from SNPA (INTERFACE-NAME). This system received a pdu reporting an invalid number of configurable area addresses. This system only accepts values of 0 and 3 (both indicate 3). The packet has been ignored.), (Recommended Action: Identify the source of the offending packet and correct it. If the message recurs 'debug isis packet-errors detail' may be used to provide a dump of the problematic PDU.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-ERR_EVM_SEND_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to send the specified message. The cause may be a resource starvation problem but is most likely to be an internal programming error. The error message should give more details.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Restart the IS-IS process. *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-IOFPGA_INTERRUPT ### Response: (Severity: 3), (Category: DRIVER), (Description: Card manager has detected that IOFPGA board has reported an interrupt. This interrupt may be fatal and may cause system to reset. If system goes power down then user needs to power cycle the system.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD-4-MEM_POLL ### Response: (Severity: 4), (Category: HA), (Description: An error was encountered during wdsysmon's poll for system memory usage.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: G709-6-PRBS_INFO ### Response: (Severity: 6), (Category: L2), (Description: This is an informational message to know stage of PRBS test whether it has been started/stopped with specified mode and pattern.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RUNTIME-2-SVC_CRIT ### Response: (Severity: 2), (Category: OS), (Description: A service API information is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_TDM-7-COLD_RESTART ### Response: (Severity: 7), (Category: HA), (Description: A process failed to restore state from a table in the checkpoint store.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCM_SWITCH-5-DUAL_ROUTER ### Response: (Severity: 5), (Category: PLATFORM), (Description: This is an info message indicating that the router is booting as a dual router.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEPKI-1-CERT_EXPIRED_ALERT ### Response: (Severity: 1), (Category: SECURITY), (Description: Cerficate has expired. Immediate action is required.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: scripts-3-NODEID_EXTRACT_FAIL ### Response: (Severity: 3), (Category: L2), (Description: An error occured as rack/slot/instance couldn't be extracted and the process will exit. This may be program level error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-3-RECORD_LENGTH_UNMATCH ### Response: (Severity: 3), (Category: OS), (Description: The message received by an application had inconsistent record length.), (Recommended Action: This happens when a client sends corrupted data to obflmgr. Please copy the file to a different location, clean the corresponding feature file and restart obflmgr. CLI to clean the file: admin clear logging onboard if the issue is seen even after this step, then collect the following data and contact support. 1. admin show logging onboard trace manager severity info location all 2. admin show logging onboard trace config severity info location all 3. admin show logging onboard trace lib severity info location all 4. show logging 5. admin show logging onboard raw location 6. Collect running core dump of the process: CLI: dumpcore running obflmgr) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-HIGH_BIAS_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP bias greater than or equal to the high bias warning threshold. The CFP is the pluggable optics on the line cards. The bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-3-INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: An initialization error has occured for IPv4 Forwarding Information Base.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COREHELPER-3-DESTROY_EVENT_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Failed to destroy sync event manager.), (Recommended Action: Check corehelper process, collect console logs, show context. Report this message to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS VPN hub and spoke feature? ### Response: The MPLS VPN hub and spoke feature allows a VPN to be configured in a hub-and-spoke topology, with the hub PE router importing and exporting routes to and from spoke VPN sites. It simplifies VPN connectivity and provides a way to share services from a central site. Hub and spoke VPNs are implemented using route target import/export between hub and spoke PE routers. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_IPCP_OPTS_INCONSISTENT ### Response: (Severity: 4), (Category: L2), (Description: PPP MA has negotiated inconsistent IPCP options. The message details which options are inconsistent. IPCP will be brought up, but the inconsistencies could cause problems. The most likely reason for this is a misconfiguration, either locally or on the peer.), (Recommended Action: Consider changing the relevant configuration either locally or on the peer.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ-3-ERR_MEM_ALLOC ### Response: (Severity: 3), (Category: FABRIC), (Description: Ingressq encountered a fatal memory allocation error. If a new configuration being applied, the configuration will be rejected. The user may reapply the configuration. If the error happens during normal operation, the process will restart to recover from this error.), (Recommended Action: The driver/client processes try to recover from this error. If any discrepancies are found in the device functionality, contact TAC Support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-2-TAIKO_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: The taiko power alarm was encountered), (Recommended Action: Node will be shutdown immediately as hardware error occured.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_ET0_INTR_MISSING_EOP_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_ET0_INTR_MISSING_EOP interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-LOCATE_SYMLINKS_FILE ### Response: (Severity: 3), (Category: OS), (Description: An expected startup configuration file for QSM could not be found. This could be due to an install problem or due to data being deleted from the installation file system. QSM will continue startup-up, but some system functionality may be impared.), (Recommended Action: Your installed file system is missing a file. Perform a re-install to refresh the missing file. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-TABLE_DELETE ### Response: (Severity: 3), (Category: OS), (Description: Unable to delete object from table.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-MFI_CLIENT_ERR ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS encountered an unexpected error using the Managed Timer library. This is most likely to be due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the IS-IS process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2VPN_FGID-4-LTRACE_INIT ### Response: (Severity: 4), (Category: PLATFORM), (Description: Failed to initialize the ltrace module in the platform L2FIB (D)RP component.), (Recommended Action: Platform software will correct itself if this happens. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RLOGIND-3-ERR_DEBUG_INIT ### Response: (Severity: 3), (Category: IP), (Description: Internal error.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-LANE_2_HIGH_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power greater than or equal to the high Rx power warning threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-6-COMM_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: PLATFORM FIB, Information), (Recommended Action: The message is just for information. No action is needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_RIB-3-BIND ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred on a request to bind to the RIB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-6-NVRAM_READ_FSTYPE ### Response: (Severity: 6), (Category: MEDIA), (Description: The ROMMON variable for format option is unknown, so that format operation will not happen.), (Recommended Action: Please do not set ROMMON variable by hand.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERG-4-NEG_ERROR ### Response: (Severity: 4), (Category: INFRA), (Description: The SERG role negotiation between peer routers has encountered error in specified role. This is a warning and would break the session sync if it is not resolved i.e if both peer routers are either in master or slave mode. Normally if this is transient condition it will resolve by itself.), (Recommended Action: Check to ensure that the two peering routers have different SERG roles for the specified group. If not, verify that the initial preferred role is not configured to be the same on both ends. Fix configuration inconsistency and then disable/enable the group to rectify the condition.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-3-MEM_ALLOC_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: A memory allocation operation failed.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-3-NBR_DOMAIN_CERT_INVALID ### Response: (Severity: 3), (Category: SERVICES), (Description: 'The domain certificate of the neighbor device ' 'is invalid'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_VPN_MIB-3-ERR_DLL_SYMBOL_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Cannot find DLL symbol error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-SYSDB_REG_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace sysdb error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace sysdb error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show sysdb trace client-errors command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show sysdb trace client-errors output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IKE-3-ERR_2_PARAM ### Response: (Severity: 3), (Category: SECURITY), (Description: IKE general error message with two prameters.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASIC_SCAN_SERVER-3-ERR_IO ### Response: (Severity: 3), (Category: L2), (Description: ASIC scan server has failed the specified io operation.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-SJTAG_FAILURE ### Response: (Severity: 3), (Category: DRIVER), (Description: FPGA is monitoring the JTAG clk line. If it found clk line has any activity then it will generate the fault SJTAG fault indicates that someone tried to tamper with t the board which is a security concern. FPGA will hold CPU to reset on this fault), (Recommended Action: This is an indication of security breach and will require RMA of the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_THOR_L2FIB_LOCSW-7-DEBUG_WARNING ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB LOCSW component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_TX_AHS_LOS_LANE2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OT-6-TRACK_INFO ### Response: (Severity: 6), (Category: SERVICES), (Description: Internal information. for example: track state changes.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-3-ENCAP ### Response: (Severity: 3), (Category: L2), (Description: An error occurred processing a request to set mfr encapsulation on an interface.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBI_HELLO-2-HBLOSS_COLLECT_LOGS ### Response: (Severity: 2), (Category: PLATFORM), (Description: Shelfmgr detected partial heartbeat loss for this node. Debug logs are collected on the bootflash locally to help identify the the root cause of the heartbeat loss.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure a VRF in IOS XR? ### Response: To configure a Virtual Routing and Forwarding instance, use the 'vrf' command in global configuration mode. RP/0/RSP0/CPU0:router(config)#vrf Customer_A RP/0/RSP0/CPU0:router(config-vrf)#address-family ipv4 unicast RP/0/RSP0/CPU0:router(config-vrf-af)#exit <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_THOR_L2FIB_LOCSW-7-PFI_WARNING ### Response: (Severity: 7), (Category: PLATFORM), (Description: Failed to initialize the PFI-IFH module in the platform L2FIB LOCSW component.), (Recommended Action: None, platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-CONTEXT_REGISTRATION ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ERR_SYSDB_API ### Response: (Severity: 3), (Category: MGBL), (Description: 'Unable to perform a sysdb api call. The module which is calling this api, the description of the api and the error is displyed in the error message.'), (Recommended Action: collect show nvgen trace, show logging, any abnormal console message, and configuration of the router. Then send this output to tech support) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-0-LC_ACT2_IDENT_FAILED ### Response: (Severity: 0), (Category: PLATFORM), (Description: Hardware in the specified location could not be verified as a genuine Cisco product.), (Recommended Action: Please copy the error message exactly as it appears on the screen and gather the output of CLIs 'show diag eeprom-info', 'show tech-support ethernet interfaces'. Please ensure that the line card daughter board card type, board PID and serial number are not modified. Contact your technical support representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DIAG-6-NO_DIAG_RUNNING ### Response: (Severity: 6), (Category: DIAG), (Description: An attempt to stop a diagnostic test that was not running was made.), (Recommended Action: None. This is an informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: JACKET-4-QFP_FAILURE_BRIDGE_BIND ### Response: (Severity: 4), (Category: L2), (Description: Failed multiple attempts to bind to QFP SPA bridge controller server), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers QFPCPUBridge trace <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers QFPCPUBridge trace <> output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSU-3-IDPROM_ACCESS_FAILED ### Response: (Severity: 3), (Category: LIBRARY), (Description: Software cannot read the power module's IDRPOM.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_EVM_CONN_OPEN ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FHRP-4-WARN_INIT ### Response: (Severity: 4), (Category: IP), (Description: The FHRP library failed to initialize correctly. In this situation HSRP/VRRP restarts, but may not recover if there is a persistant error in the IOSXR system and HSRP/VRRP is still unable to reestablish its connections and initialize successfully.), (Recommended Action: If HSRP/VRRP does not restart and automatically recover, do the following. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-PROVISION_STARTED ### Response: (Severity: 4), (Category: MEDIASVR), (Description: This ios_msg is raised when a provision disk request for either DETACH/ATTACH is triggered), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TEMPERATURE_ALARM-2-DIE_OVERTEMP_CRITICAL ### Response: (Severity: 2), (Category: PLATFORM), (Description: LC on die temperature sensor is risen above or fallen below critical threshold.LC or Port will be shutdown in 24 Hrs), (Recommended Action: Verify the failure, use show env to help. If the failure does not alleviate, LC or port will shutdown. Call your technical support representative for repair or replacement.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAM_MANAGER-3-PAM_WATCH_ERROR ### Response: (Severity: 3), (Category: OS), (Description: Automated faulty event (crash/memory leak/show logging pattern) monitoring.), (Recommended Action: Check pam_manager process, show context, collect console message. Report this message to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-TAP_READ_FAILED ### Response: (Severity: 3), (Category: FABRIC), (Description: TAP read consumed too much time.), (Recommended Action: collect the logs mentioned above) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-MEM_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBMIRROR-3-ERR_POLL_WRONG_FD ### Response: (Severity: 3), (Category: MGBL), (Description: There appears to be some corruption related to poll.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GATM-6-SUBIF_STATE_CHANGE ### Response: (Severity: 6), (Category: L2), (Description: Informs about the state changes of the subinterface. first %s --> The method name next two %s --> TRUE/FALSE next two %x --> interface handles for the sub and main interfaces respectively.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MRIB-4-GEN_WARN ### Response: (Severity: 4), (Category: ROUTING), (Description: A general warning.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SNMP-3-SUBAGENT_REG_COMPLETE ### Response: (Severity: 3), (Category: SNMP), (Description: This syslog will indicate that all subagents have completed their registration with snmpd. This syslog is introduced to indicate timeout seen with syslog OID_SUBTREE_MISSING is now recovered. In scaled router, sometimes mib take more time to complete its initialization, this syslog will help to indicate that timeout has recovered itself.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-DLL_INIT ### Response: (Severity: 3), (Category: FORWARDING), (Description: Tunnel IP Lookup DLL failed to initialize a critical component and might not function properly.), (Recommended Action: Please provide the output of the following command: show tech-support tunnel-ip) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GIRO-4-CFG_SAVE_SINGLE_INTF ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Configuration could not be saved for this interface prior to the interface being deleted.), (Recommended Action: When this interface is re-created, re-enter desired configuration manually.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC_CMN-5-rest_global_queue_limit ### Response: (Severity: 5), (Category: OS), (Description: Too many REST sessions opened or REST API is generating events faster than REST client can consume.), (Recommended Action: All REST connections were already disconnected. Decrease number of generated notifications by decreasing number of elements related to subscribed notifications (number of nodes, links or prefixes in topology if client is subscribed for topology notifications or number of LSPs if clients is subscribed for LSP notifications) or solve network issue causing increased number of events. If number of notifications is expected, then expected performance limits with supplier of REST client.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPIO_PD-3-NULL_EVM ### Response: (Severity: 3), (Category: PLATFORM), (Description: Protocol packet path initialization failed due to no packet event notification registered from protocol module. Initialization is aborted and may be retried.), (Recommended Action: Restart the protocol process. 'process restart location <>' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PM-5-ERR_MEM ### Response: (Severity: 5), (Category: MGBL), (Description: The system is running out of memory and was not able to allocate sufficient memory to carry out a collection operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-4-VPWS_MPLS_SRV6_MISMATCH ### Response: (Severity: 4), (Category: L2), (Description: An EVI/EAD route was received for an MPLS VPWS that is missing a label, or for an SRv6 VPWS that is missing a SID. Most likely scenario is that the remote side is configured for a different encap than the local side.), (Recommended Action: Perform network level review, and ensure that services are configured as MPLS or SRv6 as appropriate.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYNCFS2-3-REGISTER_NTFN ### Response: (Severity: 3), (Category: MEDIA), (Description: Syncfs failed to register with qsm/lrd for notification), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-FATAL ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Null Driver partner encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: Collect console log and the following information and contact TAC support with this info Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. -show platform -show process spp -show process netio -show process pakman -debug netio drivers location -show logging process spp -show logging process netio -show logging start [time of day when this msg was seen] -show netio idb all brief location -show netio trace all location ) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY-4-SYSDB_DELETE_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: The policy_repository process encountered an error while trying to remove the data for a deleted policy.), (Recommended Action: This can only occur when there are no references to the deleted policy in the first place, and therefore will not have any harmful effects. Please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EIGRP-4-CERR_REG_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: This system was unable to register the internal error DLL. This is probably due to a faulty installation.), (Recommended Action: Be sure the libeigrp_error.dll is present in lib/cerrno. If the DLL is present, the process must be restarted before it can function correctly. If the DLL is not present, then the problem is with image installation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: Multilink-3-INCORRECT_BW_UPDATE ### Response: (Severity: 3), (Category: L2), (Description: When the indicated member link was deactivated, bundle bandwidth could not be updated correctly as decrementing the link's bandwidth would have made the bundle bandwidth to go below zero. Bundle bandwidth is now made zero.), (Recommended Action: Check the bundle and member interface status. Verify that the bundle bandwidth is correct now. If not, shut all the members of the bundle and then no shut all the members to bring back the bundle bandwidth to correct value.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_7_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_7 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-HAL_ERR_SLOT ### Response: (Severity: 3), (Category: PLATFORM), (Description: A card or slot level HAL API function has failed in Shelf Manager. The details are supplied in the msg.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_CHOPPER-6-INFO ### Response: (Severity: 6), (Category: L2), (Description: This message indicates an informational message. This message is added for debugging purpose.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-HB_DECODE_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that decoding of TLV format HB message failed with the indicated error code and error message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-7-ERR_MEM_ALLOC ### Response: (Severity: 7), (Category: FABRIC), (Description: FIA driver memory allocation error. Memory allocation failures will happen if the the router runs out of memory or memory leak in this process or other processes. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYNCFS2LIB-6-LOST_SYNC ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKT_CLASS-3-VRF_REGISTER_FAILED ### Response: (Severity: 3), (Category: OS), (Description: The Linux Packet classifier failed to register for Linux Socket events taking place in the specified Linux Network Namespace. This may cause packets which should be handled by Linux applications to get dropped.), (Recommended Action: Attempt to recover by restarting the xlncd process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-3-ERR_INIT ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: netio initialization error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-MEMORY_LIMIT ### Response: (Severity: 3), (Category: OS), (Description: The virtual service machine definition file is requesting more memory than the system has available for virtual services.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_PAK_CLIENT_ACCESS ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS encountered an error while accessing a packet buffer. The relevant packet has been ignored. The message describes the nature of the error. If the problem is transient then IS-IS will recover. The error may be due to a low memory condition.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*. Consider restarting IS-IS.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OCIFIP_V6MA-3-INTERNAL_ERR ### Response: (Severity: 3), (Category: IP), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-2-SC_CARD_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Shelf controller is failed due to i2c hung even after all possible recovery action.), (Recommended Action: This condition indicates a potential hardware problem with the card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-ASIC_CS_ERROR ### Response: (Severity: 3), (Category: OS), (Description: An unexpected error occurred.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_STATIC-3-RIB_INTERFACE ### Response: (Severity: 3), (Category: ROUTING), (Description: The static routing process failed unexpectedly to update RIB after an interface state change event.), (Recommended Action: Check the routing table to see whether any static routes are missing(Use 'show route {vrf }').) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-3-VER_MISMATCH ### Response: (Severity: 3), (Category: PLATFORM), (Description: SyncAgent has detected incompatible versions between its Client API and the currently-running server.), (Recommended Action: Update the software image on all nodes to use the same SW version.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPENET-2-MDI_READ_FAILURE ### Response: (Severity: 2), (Category: PLATFORM), (Description: A PCI bus transaction on the device has failed due to an inconsistency between the hardware and software state of the ethernet device. To recover, the driver must be restarted and the hardware reset.), (Recommended Action: No end user action is needed. If the problem is not corrected by a device and driver reset, then there is a hardware issue and the device is deffective.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-CORRUPT_CONTEXT ### Response: (Severity: 6), (Category: OS), (Description: Looks like the core context infomation dumper stores is corrupted. The conext is being reset, all existing context infomation will be lost.), (Recommended Action: This is an informational message.Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-3-ATTRIBUTE ### Response: (Severity: 3), (Category: ROUTING), (Description: FIB maintains a per-table attribute database, but was unable to process it.), (Recommended Action: Try restarting the fib process to see if the problem goes away. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-3-HIGH_TEMP_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK temperature greater than or equal to the high temperature warning threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted, the fan is operational and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMHAD-7-ERR_INIT ### Response: (Severity: 7), (Category: OS), (Description: The Platform Manager HA Driver DLL was unable to initialize due to internal software resource issues.), (Recommended Action: The Platform Manager HA Driver DLL will exit and the client process should handle the error accordingly. Please exam the output of show logging to see if similar issue had occured.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPAQFPBridgeCtrl-1-RX_ESPI4_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: SPA Bridge ASIC detected a FRAME/FIFO_OVF/DIP2/OOF Error.), (Recommended Action: Restart the Jacket Process. If the problem persists, reboot the card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-3-NSR_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: BFD NSR SM failed because of the timer init failure.), (Recommended Action: Restart corresponding bfd process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSUDIR-1-OPERATION_ISSU_LOAD_DONE ### Response: (Severity: 1), (Category: INSTALL), (Description: The ISSU Load operation has completed successfully.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-4-GASP_INIT_FAIL ### Response: (Severity: 4), (Category: FABRIC), (Description: Failed to initilise fabric CDR Driver for gaspp infra. It won't affect normal working of CRD driver.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-0-ASIC_ERROR_RELOAD_SYS ### Response: (Severity: 0), (Category: PLATFORM), (Description: An ASIC error has occured and need to reload system), (Recommended Action: An error has happened and need to reload the system. Collect required information and contact TAC *None*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-BACKUP_BOOTLOADER_LOADED ### Response: (Severity: 3), (Category: DRIVER), (Description: The Backup Bootloader images has been loaded on the indicated card. This can happen when card manager detects that the Primary image is corrupted, and the HW fallbacks to load the backup image to recover from the failure.), (Recommended Action: Although the system will continue to run, the backup image set might be of older version and it might have known issues that have been fixed on latest version. So it is critical to address the problem as soon as possible. The output of 'show hw-module location fpd' will identify the image with the problem with NEED UPGD state and it will have missing Programmed version. To correct the problem, use the 'upgrade hw-module location fpd ' command to re-program the FPD image and power-cycle the affected card for IOFPGA to load with the upgraded image.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-7-FILE_OPEN_ERR ### Response: (Severity: 7), (Category: HA), (Description: Resmon library failed to open file to write processname.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-VPWS_INVALID_ETH_TAG ### Response: (Severity: 3), (Category: L2), (Description: An EVI/EAD route with ethernet tag 0 was received for a VPWS service. Most likely scenario is that the remote side is configured for a different type of service.), (Recommended Action: Perform network level review of EVPN configuration, and ensure the correct service types are being used.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-HARD_RESET_LOGGING ### Response: (Severity: 4), (Category: PLATFORM), (Description: This is an warning message to indicate that the user made a change collecting the NPDatalog during an NP recovery action.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WDMON-3-HOSTOS_HEARTBEAT_EXCHANGE_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: Host OS failed to respond to heartbeat exchange request. Card will reload if the system is unable to correct this condition on its own.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-CHKPT_INVALID_TABLE_NAME ### Response: (Severity: 3), (Category: PLATFORM), (Description: An invalid checkpoint table name was detected. The affected checkpoint operation will not be processed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QNET-3-ARM_DEVICE_ERR ### Response: (Severity: 3), (Category: OS), (Description: This is during the device Initialization. Could not arm the device to pulse us on data available), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How can you enable Ethernet OAM on an interface in Cisco IOS XR? ### Response: To enable Ethernet OAM on an interface in Cisco IOS XR, use the 'ethernet oam' command in interface configuration mode. You can also configure Ethernet OAM parameters such as the mode (active or passive), link monitoring, and remote loopback using the 'ethernet oam' command. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHMWIN-3-MUTEXOP_FAILED ### Response: (Severity: 3), (Category: OS), (Description: SHMWIN encountered an error condition, a mutex operation failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Capture - show logging - show shmwin trace all location 0/x/CPUx - dumpcore running location 0/x/CPUx) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_ASIC-3-HEALTH_MONITOR_PON_RECOVERY ### Response: (Severity: 3), (Category: L2), (Description: An Beluga SW error has occurred and requires pon-reset to recover. The Beluga ASIC was in a Halt state for and extended period..), (Recommended Action: This informational message indicating that the required error recovery action took place.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCASTSN-3-DP_CONGESTION ### Response: (Severity: 3), (Category: L2), (Description: Applications are providing state change to the layer 2 multicast data plane hardware faster than the hardware can be programmed. Internal message to the hardware have been dropped such that IGMP snooping state is now out of sync with the hardware. The user must slow the rate of IGMP state change being received by the system. The system will automatically recover from this condition once the rate of IGMP state change has been reduced.), (Recommended Action: The user must slow the rate of IGMP state change being received by the system. The system will automatically recover from this condition once the rate of IGMP state change has been reduced.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-LANE_0_HIGH_BIAS_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Check installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-CPP_PKT_F0_MBE ### Response: (Severity: 0), (Category: PLATFORM), (Description: IBS from CPP packet FIFO 0 multiple bits error.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-4-QSM_ADD_SERVICE_ERROR ### Response: (Severity: 4), (Category: OS), (Description: QSM publish obfl config master path failure), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-6-MCU_DOWN_REV ### Response: (Severity: 6), (Category: PLATFORM), (Description: To support console tunneling, MCU firmware must be at v5 or higher.), (Recommended Action: upgrade MCU) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-4-CRASH_INFO ### Response: (Severity: 4), (Category: OS), (Description: Debug crash info), (Recommended Action: Information of the crashed process. Ignore.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-6-INFO_MSG ### Response: (Severity: 6), (Category: L2), (Description: This is a informational message in the NPU Driver to indicate an operation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-MISSINGEQUALSIGN ### Response: (Severity: 3), (Category: MGBL), (Description: 'The equal is missing in sysdb string. The sysdb string and the command are displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-REVERSION_FAILED ### Response: (Severity: 5), (Category: ROUTING), (Description: This is to notify that reversion has failed for a tunnel.), (Recommended Action: None. This is a solicited message and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-CERR_REGISTER ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred during the registration of OSPFv3 error codes.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_FILESAVE ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-CREATETHREAD ### Response: (Severity: 3), (Category: MGBL), (Description: 'pthread_create() API failed due to mentioned error'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR backup tunnel interface feature? ### Response: The MPLS TE FRR backup tunnel interface feature allows a physical interface to be used exclusively for TE backup tunnels, rather than also carrying normal traffic. The backup tunnel interface is not advertised in the IGP and is not used for SPF calculations. This dedicates the interface resources for backup and avoids potential congestion from regular traffic. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'import route-target' and 'export route-target' commands in IOS XR L3VPN configuration? ### Response: The 'import route-target' and 'export route-target' commands are used to control the import and export of routes between VRFs. The 'import route-target' specifies which routes should be imported into the VRF from other VRFs. The 'export route-target' specifies which routes should be exported from the VRF to other VRFs. Route targets define the VPN membership and allow the creation of extranets. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-6-SATELLITE_LOGIN_SUCCESS ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: This indicates that a user has successfully logged into the specified satellite.), (Recommended Action: *DEBUG*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SIM_SE-5-SW_INFO ### Response: (Severity: 5), (Category: PLATFORM), (Description: For displaying SIM Service Engine information message.), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMATTR-3-DUPLICATE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The attribute client has received duplicate successful responses for this attribute on this interface. This would suggest that multiple attribute owners have been configured for this (interface, attribute) pair.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-7-MMAP_FAILED ### Response: (Severity: 7), (Category: OS), (Description: mmap system call failed. This might impact the core file.), (Recommended Action: Contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-3-ATTR_SET_FAIL ### Response: (Severity: 3), (Category: SYSDB), (Description: An error occurred during initialization of detach state sysDB pthread attribute.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How do you configure SNMP on Cisco IOS XR? ### Response: To configure SNMP on Cisco IOS XR, you need to define SNMP communities, set access privileges, specify the host to receive SNMP notifications, and optionally configure SNMP traps and inform requests. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INV-6-IF_OIRIN ### Response: (Severity: 6), (Category: PLATFORM), (Description: SFP or XFP or CFP or QSFP entity is inserted into the line card.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AAL-3-ERR ### Response: (Severity: 3), (Category: HA), (Description: A critical error occurred in NPU Driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VEEA-3-BCMDPA_L1_PORT_CREATION_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: BCMDAP L1 port creation failure.), (Recommended Action: Collect show tech-support fabric, DPA.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between the single-topology and multi-topology models in IS-IS? ### Response: In the single-topology model, IS-IS uses a single SPF calculation for both IPv4 and IPv6 routes. In the multi-topology model, IS-IS maintains separate topologies and performs separate SPF calculations for IPv4 and IPv6. This allows for greater control and flexibility in routing. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_FPD-6-UPDATE_PASSED ### Response: (Severity: 6), (Category: L2), (Description: The FPD image was updated successfully.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does Cisco IOS XR handle software package dependencies during installation? ### Response: Cisco IOS XR automatically resolves software package dependencies during the installation process to ensure that all necessary components are installed for the proper functioning of the added packages. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-UNKNOWN_NODE_TYPE ### Response: (Severity: 7), (Category: INSTALL), (Description: Either the card type may be invalid or the infrastructure is behaving incorrectly. The current request or operation has not been carried out.), (Recommended Action: Upgrade to latest OS release. Check for unsupported hardware.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO_API-3-SHM_VERSION_MISMATCH ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Shared memory version missmatch.' 'process will exit with failure.'), (Recommended Action: 'Retry the issu operation.If error persists.' 'Contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP_CLIENT-4-EXIT_ON_ERR ### Response: (Severity: 4), (Category: L2), (Description: An error occurred in the NP client library after which the client code cannot continue. This error is encountered when a client module (e.g. cli command) has difficulty retrieving information from the NP driver. The root cause may be located in either hardware or software.), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_GCO-6-UPDATE_ABORTED ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: Package update requested on this satellite has been aborted, as requested by the user. Run 'show nv satellite status' for more information about the current state of the satellite.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-3-LTRACE_INIT_ERR ### Response: (Severity: 3), (Category: L2), (Description: PLIM process encountered an error during software initialization. ltrace initialization is failed. So we will not get any traces using ltrace Cli.), (Recommended Action: Check if the linecard reported any other errors and/or traffic loss was observed. There was problem with hardware or software initialization. This problem can be resolved by reloading the LC 'hw-module location <> reload' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-2-DEV_CFP_SUPPORTED_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: A supported error was detected during CFP initialization. A support error is reported when the CFP type can not be determined or it is not supported on the platform. The CFP is the pluggable optics on the line cards. CFP initialization may happen when linecard boots up, CFP OIR and line card process restart. The optics will not be enabled if an CFP supported error is detected.), (Recommended Action: Verify that the device is properly inserted. Check optic supportedness from the Cisco CCO document 'Cisco ASR 9000 Transceiver Modules: Line Card Support'. Also, check 'show controller internal' to see whether optic is supported or not. Check all the FPDs are upto date using 'show hw-module fpd location all'. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_LSD-3-ERR_SRLB_RANGE ### Response: (Severity: 3), (Category: ROUTING), (Description: LSD received a request for an SRLB range that has conflicting labels present. Configured SRLB cannot be fully allocated.), (Recommended Action: To clear inconsistencies, please run 'clear segment-routing local-block'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure an L2VPN to use a specific LSP for transport? ### Response: To configure an L2VPN to use a specific LSP for transport, use the 'mpls traffic-eng' commands in global configuration mode. mpls traffic-eng tunnels interface Tunnel0 destination 10.1.1.2 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSLA-4-ERR_MEM ### Response: (Severity: 4), (Category: MGBL), (Description: IPSLA modules are failed to allocate memory due to low memory conditions in the System.), (Recommended Action: Increase System Memory or stop some applications which are not required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYNCFS2-7-LRD_AVAILABLE ### Response: (Severity: 7), (Category: MEDIA), (Description: The Standby card has been inserted and sync will be started), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PBR_EA-3-RLB_PROG_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: RLB programming failed due to hardware error. Some of the flowspec rules (packet length/source port/destination port range) are not programmed.), (Recommended Action: No action is required. The message means that this range cannot be programmed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-6-SERVO_EVENTS ### Response: (Severity: 6), (Category: PLATFORM), (Description: PTP Servo state transition event), (Recommended Action: This message is for information only, no further action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SESVI_EA-3-STATE_CHANGE ### Response: (Severity: 3), (Category: SERVICES), (Description: While the SESVI EA process was checking the state for the specified interface pair, an error was encountered. The interface pair in question may be left in an inconsistent state.), (Recommended Action: It may help to restart the SESVI EA process. If there are any obvious resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_SEG_HDR_FIFO_OFLOW_1_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Egress seg hdr fifo overflow on xaui-1 bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_COMM_DRVR-3-ERR_DRV_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric driver encountered the annunciated error during the driver initialization. The System Manager process (sysmgr) will automatically respawn the (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-6-BOOT_OVERRIDE_CMD_DEPRECATED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This informational message informs the user that this command is deprecated. Rack Serial number is empty for RPs/SCs with ROMMON 1.3 or older. Software (Shelfmgr process) no longer honors boot requests from such RPs/SCs.), (Recommended Action: Please upgrade the booting RP/SC to the latest recommended ROMMON.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-SRV6_INTERNAL_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: The SRv6 SID processing internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_EDM-3-SYSDB_REG_EDM_FAILED ### Response: (Severity: 3), (Category: IP), (Description: IPv4 Management Agent encountered failure in registering as a server for managebility requests. It will recover itself by restarting. Typically this error is caused if sysdb is unavailable for an extended period or if there is another process that instance that is registered as the server for the same information.), (Recommended Action: If the problem persists get the output of show processes, show sysdb trace edm, show sysdb trace clientlib job . If multiple instances of ipv4_ma are seen running or trying to run (this can be due to a bug in some other area of the system), make sure that only one instance is allowed by killing the other one.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA_DRVR-3-ERR_DLL_OPEN_FAILED ### Response: (Severity: 3), (Category: FABRIC), (Description: 'Fail open the dynamic library.check the library is exist or not '), (Recommended Action: check the library) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_EVM_MESSAGE_ATTACH ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA_TP-3-ETMM_CHKPT_DEL_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Internal error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATTACH-3-SERVER_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Attach server failure. %s- Failure message. %s - Reason for the failure.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SBCSVI_EA-3-LINK_FAIL ### Response: (Severity: 3), (Category: SERVICES), (Description: An error occurred while attempting to join together the two halves of some SBCSVI pairs on the specified node. The pairs will not come up. If there is a standby node configured for the pairs, they may come up on the standby.), (Recommended Action: It may help to shut down, then bring up, the SBCSVI interface pairs in question.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-7-THREAD_CREATE_FAILED ### Response: (Severity: 7), (Category: PLATFORM), (Description: Thread create failed), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPPHA-3-INITFAIL ### Response: (Severity: 3), (Category: L2), (Description: A CPP HA initialization failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show logging command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show logging output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EOBC-3-PKT_ERRORS_LC19 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Switch MAC detected excessive packet errors on link), (Recommended Action: Verify that the link errors are present and persistant. Get link counter: 'show controller backplane ethernet switch link location ' Get link state: 'show controller backplane ethernet links location ' Get show tech: (admin)'show tech-support control-ethernet location ') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-2-GET_EVENT_STATE_ERROR ### Response: (Severity: 2), (Category: HA), (Description: Error seen while trying to fetch the state of the given node event.), (Recommended Action: If any of these messages recur, call your technical support representative for assistance.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSRP-4-ERR_MGD_TIMER ### Response: (Severity: 4), (Category: L2), (Description: SSRP encountered an unexpected error using the Managed Timer library. This is most likely to be due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the PPP MA process. *RECUR*.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-4-DISK_FATAL_EVENT ### Response: (Severity: 4), (Category: DRIVER), (Description: The host OS is reporting a disk fatal event while performing primary volume health check.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-ENS_READ ### Response: (Severity: 3), (Category: FORWARDING), (Description: This message indicates that a client process issued ens_read and it failed. This failure is because the server, IP Tunnel Management Agent, is either busy or there is problem in GSP communicatoin.), (Recommended Action: Please try restarting the client process with command process restart location . Process name and location are included in the message already. If the problem persists, please contact Cisco TAC and provide this message text as well as the information specified in required_info section.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-4-UNEXPECTED_BPDU_RECEIVED ### Response: (Severity: 4), (Category: L2), (Description: A BPDU was received on a port that was configured for Portfast. This port will now revert to a 'non-edge' port.), (Recommended Action: Check network configuration. Should this port really be configured for portfast? Has a new network device been added to the network?) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STATS_INFRA-3-ERR_EVENT_MGR ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occurred in stats infra during event manager creation), (Recommended Action: Restart the process using CLI command in exec mode -process restart statsd_server If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RADIUSD-6-BAD_ATTR_TYPE ### Response: (Severity: 6), (Category: SECURITY), (Description: An internal software error has occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLMGR_OBJ_LIB-3-MUTEX ### Response: (Severity: 3), (Category: PLMGR_OBJ_LIB), (Description: The policy obj library had trouble locking/unlocking mutex.), (Recommended Action: Identify the process name and job id that report the error from the printed out message, then collect running core dump via clis 'dumpcore running ', and 'show process blocked', then contact TAC with the output, which will be used only for internal diagnosis purpose. Then restart the process via cli 'process restart '.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-4-CARD_YELLOW_OVERTEMP_CLEAR ### Response: (Severity: 4), (Category: PLATFORM), (Description: Card temperature has returned 2 degrees below the configured yellow threshold.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-3-HA_ABORT ### Response: (Severity: 3), (Category: L2), (Description: Openflow plug-in has encountered an error during HA restart and needs to be cold started.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MDACON-4-NOTLEAF ### Response: (Severity: 4), (Category: MGBL), (Description: The entered class name is not a leaf class, as is expected by the command.), (Recommended Action: Use the classinfo command to get more information about available class names. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLMGR_UI-4-LTRACE ### Response: (Severity: 4), (Category: APP_INFRA), (Description: The policymgr ui library ltrace infrastructure encountered an error during initialization or displaying ltrace messages, as indicated in the syslog. This should not affect the normal functioning of the system.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PAKSRV-7-MUTEX_MONREG_FAILED ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: Packet server failed to register for the mutex revival and will exit. It will be restarted by sysmgr.), (Recommended Action: If packet manager is unable to start up after several restarts by sysmgr, please collect the 'sh log' output and contact your customer support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-3-INVALID_ARGUMENT ### Response: (Severity: 3), (Category: PLATFORM), (Description: An invalid argument was passed. This might be a program level error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARDMGR-3-PCMCIA_INIT_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PCMCIA initialization error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please check the card is inserted properly if it is externally accessible. Capture 'show media' and 'show filesystem ' together with console log.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-2-REPLACE_COMMIT_ABORTED ### Response: (Severity: 2), (Category: INSTALL), (Description: Specified message provides info that the install commit triggered as part of replace operation has aborted.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERG-3-AGT_INIT_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: An error occurred during initialization, causing SERG Agent process to abort and it will be restarted to attempt to resolve the issue.), (Recommended Action: Contact Technical Support. Repeated occurances will affect the working of the Session redundancy feature and also have performance and scale impact on Session features in general.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ZAPDISK-3-ZAPDISK_COMPLETED ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ESD-3-PORT_AUTO_TUNE_FAILURE ### Response: (Severity: 3), (Category: INFRA), (Description: The Ethernet Switch Driver (ESD) process failed to perform Rx auto tuning for the indicated port on the control plane ethernet switch. The impact to the control ethernet connectivity will vary based on which port was affected, and on whether the port's link failed to come up or is experiencing packet errors as a result. This failure could be due to a hardware failure or a software defect.), (Recommended Action: Use the 'show controller switch statistics detail' command to check whether the affected port's link is down or is experiencing any packet errors. If not, no action is necessary. The port should be monitored to see whether the failure occurs on subsequent reloads or SFP OIRs. If the port's link is down or errors are seen on the affected port, remove and re-insert the port's SFP. If the auto tuning still fails, the port link state remains down, or packet errors persist, reboot the affected hardware card. After characterizing the auto tuning failure, collect the Ethernet Switch Driver (ESD) traces and related information using the 'show tech-support control-ethernet' and 'show tech-support ctrace' commands. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_VM_INTR_DM_UNEXP_GNT_ERR_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_VM_INTR_DM_UNEXP_GNT_ERR interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLDMGR-2-INTR_HDLR ### Response: (Severity: 2), (Category: PLATFORM), (Description: PLDMGR encountered an error while attempting to initialize the interrupt handling thread. This means that interrupts will not be serviced by PLDMGR until the process is restarted.), (Recommended Action: The problem should clear itself, as PLDMGR will automatically restart. If the issue persists, collect the following traces in exec mode and contact TAC: show controllers pldmgr trace info show controllers pldmgr trace error) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CETHHA-7-STATS_INFO ### Response: (Severity: 7), (Category: PLATFORM), (Description: Packet tx/rx statistics on CPU control ethernet port.), (Recommended Action: Remove/Replace the RP.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCE-2-L2CACHE_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: The message is displayed whenever there is a L2 cache error in CPU.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE FRR bandwidth protection feature? ### Response: The MPLS TE FRR bandwidth protection feature allows bandwidth to be reserved for backup tunnels to ensure that sufficient bandwidth is available for fast reroute traffic after a failure. It prevents backup tunnels from being used for other traffic and ensures that FRR can always redirect traffic successfully. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CT_DSP-1-ALARM_LOS_PORTR2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC_CTRL-3-MULTIPLE_PRIMARY_DSC_NODES ### Response: (Severity: 3), (Category: PLATFORM), (Description: Multiple nodes within the system have declared the Primary DSC role. This can lead to severe system instability and traffic loss as the multiple primary nodes conflict. In order to resolve the conflict, the system will reload RSP nodes until only a single Primary node remains.), (Recommended Action: If this condition persists, check the physical connection of the Interchassis control links between the RSP nodes connecting the racks. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_HT0_ERR_CMD ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an erroneous command on the HT0 HTDP interface. This means that the HT host core has received an HT Flush, Fence, or Broadcast packet. These packets are not supported and behavior is undefined after this type of packet is received. Note: CPP does not generate these commands.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLCTRLR-3-ERROR ### Response: (Severity: 3), (Category: L2), (Description: A general failure occured while executing the function in question. The message contains info about the location and cause of the failure and possibly anticipated actions/effects.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-3-AIPC_CLIENT_ERR_INTERNAL ### Response: (Severity: 3), (Category: FABRIC), (Description: Error occured during the use of FSDB AIPC Client for the given process id(name).), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_ASR9K_NSR_PACKET-2-CANT_TRIM_CLSTR_NPH ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message tells is there was an error in trimming the cluster header from the packet.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ICPE_DPM-7-CORRUPT_PERSISTENT_DATA ### Response: (Severity: 7), (Category: PKT_INFRA), (Description: Corrupt persistent data was encountered during a process restart. The data will be deleted and the process restarted automatically.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB_ALARM-3-MAC_COUNTER_LIMIT_PER_NP ### Response: (Severity: 3), (Category: PLATFORM), (Description: Bridge and bridge-port objects allocate two stats pointers for mac related features. The alarm is raised when the counters allocated exceed the platform limit), (Recommended Action: Reduce number of objects created on the NP) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFLX_LIB_MGR-3-PTFM_NODEID_ERR ### Response: (Severity: 3), (Category: SERVICES), (Description: The Interflex Manager failed to get the node id from the platform at startup. The process will be automatically restarted, if it keeps restarting with same message *DDTS*), (Recommended Action: *RECUR*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDEVINFO-3-EVM_ERROR ### Response: (Severity: 3), (Category: MEDIA), (Description: Failed in some event management functions.), (Recommended Action: restart process 'fs_dev_info' from exec prompt - from exec prompt 'restart process fs_dev_info' if issue persists contact TAC) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XLNC-4-SCRIPT_FAILED ### Response: (Severity: 4), (Category: INFRA), (Description: XLNCd runs scripts on router start up and when to XR EXIs are created. A script was run that failed.), (Recommended Action: Check the script that failed while executing. Ensure that the script does not take longer than 10s to run. Then restart the XLNCd process and undo then reapply any linux networking configuration. If the problem persists through process restarts, If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-7-HANDLE_POWER_DOWN ### Response: (Severity: 7), (Category: PLATFORM), (Description: This debug message indicates the start/end of SPC power down. Since shelfmgr power-cycles this card immediately after this parking, this message might not show up on the RP console. But if there is any delay during msg_chan_connect or power down steps, then this message will help to findout which step caused the delay.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TACACSD-4-NOSUCH_INTF ### Response: (Severity: 4), (Category: SECURITY), (Description: The interface specified as source interface is not present.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SRv6-4-SID_OOR_YELLOW ### Response: (Severity: 4), (Category: ROUTING), (Description: The SRv6 SID manager database has reached the platforms resource warning threshold. Details about the threshold can be seen with show segment-routing srv6 manager command.), (Recommended Action: If this threshold is regularly reached, it may be a sign to reduce scale of Segment Routing IPv6 entries by changing topology or VPN allocation mode in BGP from Per CE to Per VRF) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDP-3-ERR_NO_MEM ### Response: (Severity: 3), (Category: L2), (Description: CDP was not able to allocate the memory that it needed to complete the operation. CDP functionality on the affected node may be reduced until the problem is resolved.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR_API-5-NOTICE_SKIP_BUFF ### Response: (Severity: 5), (Category: PLATFORM), (Description: A double-free condition has been avoided), (Recommended Action: Please collect the following logs, show tech-support control ethernet fast location , collect dumpcore running , eth_server and bfm-server.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-BLANKENTERTUPLE ### Response: (Severity: 3), (Category: MGBL), (Description: 'The enter tuple is blank. The calling function and enter tuple are displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-WDSYSMON_EVENT_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: This indicates a problem with the event received from the watchdog system monitor.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AFMON_EA_OOR-4-LC_FLOWS_OOR_RED ### Response: (Severity: 4), (Category: PLATFORM), (Description: Performance traffic monitoring has encountered an out-of-resource condition. Performance traffic monitoring process on the linecard has detected that the number of flows being monitored on a LC has reached maximum capacity. New flows will no longer be learnt), (Recommended Action: Reduce the number of flows being monitored on the NP. This can be done by 1) Modifying ACL: (a) Remove the performance traffic service policy from the interface (b) Modify the ACL used in the service policy to be more specific to match a smaller set of flows to be monitored (c) Reapply the service policy to the interface) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_INARP-2-NOMEM ### Response: (Severity: 2), (Category: L2), (Description: Memory on the box is critically low.), (Recommended Action: Check memory conditions on the node. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GDO-7-DEBUG ### Response: (Severity: 7), (Category: L2), (Description: ATM SPA GDO L-AIS insertion/removal debug messages), (Recommended Action: *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'mpls ldp graceful-restart' command in Cisco IOS XR? ### Response: The 'mpls ldp graceful-restart' command enables the LDP Graceful Restart (GR) feature. LDP GR allows an LDP session to be maintained during an LDP process restart, avoiding the need to re-establish the session and minimizing traffic loss. It requires the neighboring routers to also support LDP GR and to maintain the forwarding state for the LDP labels during the restart. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSA-3-ERR_SYSMGR_PROC_READY ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric statistics aggregator process encountered an error to report process ready to sysmgr. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-3-INVMGR_MAX_SLICE_NUMBER_MISMATCH ### Response: (Severity: 3), (Category: PLATFORM), (Description: The NP driver received max slice number diff than existing value), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_HT1_OFLOW ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an HTDP overflow error on the HT1 interface. This error is logged when a packet is received and has no buffer available to receive it.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-4-DEVICE_ALREADY_REGISTERED_BY_ANR ### Response: (Severity: 4), (Category: SERVICES), (Description: 'The autonomic network registration authority ' 'will not allow this device to join as it already ' 'registered with a different public key'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-7-DEBUG ### Response: (Severity: 7), (Category: PLATFORM), (Description: This message is for debugging purpose only and doesn't indicate any failure), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VCDMA-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cpuctrl Event Manager create error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_IM_BATCH_STATE ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-4-RATE_LIMIT_WARNING_MP_LOW_WATERMARK ### Response: (Severity: 4), (Category: L2), (Description: BFD has released some of the previously allocated packet per second usage or number of BFD sessions and is now less than or equal to 85 percent of its allowance on at least one multipath-configured linecard.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DUMPER-6-GET_PROC_GETGREG_FAILED ### Response: (Severity: 6), (Category: OS), (Description: Dumper collects all the process related data by using system call devctl. If a devctl fails, then the core file will be incomplete. This will not impact the system.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info 3. admin show exception trace dumper-config severity info 4. show logging) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLACED-3-ZERO_RECORDS ### Response: (Severity: 3), (Category: OS), (Description: Query returned table empty.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support placed command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support placed output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-TIMESTAMP ### Response: (Severity: 3), (Category: ROUTING), (Description: An operation failed during timestamp processing.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSYNC-6-SELECTION_FALLBACK ### Response: (Severity: 6), (Category: L2), (Description: There is no longer a line or external source available for the specified selection point, so it has fallen back to the internal oscillator if available, or otherwise disabled the outputs.), (Recommended Action: This message is for information only, no further action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AIB-4-SYSTEM_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: There was an AIB initialization error. The process will attempt to recovery by restarting. There will be no effect on traffic unless shared memory is unusable, and needs to be reset.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does IS-IS handle route leaking between different levels? ### Response: Route leaking allows L1 routers to reach destinations outside their area by sending traffic to the closest L1/L2 router. L1/L2 routers can also summarize routes within their area to control route leaking. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_HEAP-7-OBJ_NOT_FOUND ### Response: (Severity: 7), (Category: HA), (Description: The object could not be found in the given table when attempting to map the object ID to a memory address.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMP-4-MSG_WARN ### Response: (Severity: 4), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-2-ASIC_FATAL_ERR ### Response: (Severity: 2), (Category: PLATFORM), (Description: Crossbar driver detected fatal ASIC error.), (Recommended Action: Please try reloading the card using command 'hw-module location <> reload' to recover. If the message occurs during every power cycle then please contact tech-support. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_SSO_ALERT ### Response: (Severity: 4), (Category: L2), (Description: PPP MA received replicated SSRP state for this interface for either which is incompatible with the local config, as identified in the error message. This means the replicated state will not be used to preprogram the session.), (Recommended Action: Check that the configuration on the Active and Standby sides of the SSRP channel is consistent. The error message should indicate which particular piece of config there may be problems with.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCDLC-6-MSG_BCDL_UNINITIALIZED_ERROR ### Response: (Severity: 6), (Category: OS), (Description: BCDL consumer dll hit some error condition.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSH_CLIENT-3-ERR_ERRNO ### Response: (Severity: 3), (Category: SECURITY), (Description: Error , Error description.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBPARSER-3-TOOMANYALIASES ### Response: (Severity: 3), (Category: MGBL), (Description: 'The system has 1000 aliases limitation'), (Recommended Action: 'please remove some unused aliases before defining more aliases' *NONE*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_BDL_DATA ### Response: (Severity: 4), (Category: L2), (Description: The data specified in the IM attribute notification cannot be interpretted. The information is invalid and the result is that adjacencies for these bundles or subs cannot be programmed in hardware.), (Recommended Action: Delete and recreate the bundles or sub-interfaces. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_2_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-6-POWER_REJECTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: 'The power required for this card exceeds the available power on this system.'), (Recommended Action: - Please collect the following CLI command to determine the current budget situation and to see if there are any failed power modules. admin show environment power-supply - Install additional power supply modules and in case of presence of failed power module(s), replace those unit(s).) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-REGCOMP ### Response: (Severity: 3), (Category: OS), (Description: The server has either failed a function that expected to succeed, or has got into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_38 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ARP-4-WARN_CLIENT_RESYNC ### Response: (Severity: 4), (Category: IP), (Description: An error occurred while resyncing data with ARP clients. In this situation ARP will schedule a retry.), (Recommended Action: The process would recover by itself as there is a retry mechanism.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_EDM-3-ENCODE_FAILED ### Response: (Severity: 3), (Category: IP), (Description: A process has requested information from ipv4_io through SysDB, probably as a result of executing a show command. The data requested could not be encoded.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB-4-IDB_PLATF_UPDATE_TOO_LONG ### Response: (Severity: 4), (Category: ROUTING), (Description: We don't expect platform updates to take too long. This can block other processes that need to communicate with fib_mgr, for instance, for config, etc.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO_COMMON-4-BLOCK_UNTIL_ACTIVE ### Response: (Severity: 4), (Category: L2), (Description: The process failed to block on System Manager on a node which is in standby role and wait for the node to go active.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR_HAL-2-CPI_SELF_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: Shelfmgr received incorrect presence indication for this RSP slot.), (Recommended Action: This error can happen if the RSP is improperly seated in the chassis. 1. Please issue the following CLI command to switch away from this RSP and make the standby RSP active: admin redundancy switchover 2. Then reseat the RSP you switched away from very carefully into the chassis, making sure it makes full contact with the backplane pins. 3. During the maintenance window, then switch back to this RSP again and verify the error has gone away. If not, there may be an issue with either this card or the chassis backplane; please contact your Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD-6-SESSION_INHERIT_OFF ### Response: (Severity: 6), (Category: L2), (Description: The specified BFD session is no longer inheriting BFD state from another BFD session.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_RIB_PATH ### Response: (Severity: 3), (Category: ROUTING), (Description: IS-IS was unable to install a path to the specified network in the specified RIB because the RIB rejected the request. This is an internal software programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MACSEC_EA-3-INIT ### Response: (Severity: 3), (Category: L2), (Description: The macsec_ea process failed to initialize, the process will be automatically restarted. MACSec functionality will be down on the affected node.), (Recommended Action: Please confirm if the process state of macsec driver is RUN. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ROULETTE-3-ERROR_EXIT ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Roulette process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Verify process is up and running, give CLI: If it is still non-operational, use CLI: If it is still non-operational, perform card reload. If still non-operational, contacting TAC and performing RSP switchover is recommended.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_DIAG-3-FAB_ERR ### Response: (Severity: 3), (Category: DIAG), (Description: The fabric diagnostic test has detected an error as part of the FIM. Fabric multicast and unicast tests aimed at identifying the faulty plane(s).), (Recommended Action: Collect the console error messages exactly as it appears on the console and call cisco support engineers with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-7-ERR_EVM_TM_ATTACH ### Response: (Severity: 7), (Category: OS), (Description: An internal error was detected when trying to allocate a timer object.), (Recommended Action: When this issue happens, it will trigger an automatic restart. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EDRM_DLL-2-SANITY_FAILURE ### Response: (Severity: 2), (Category: L2), (Description: EDRM server process encountered critical data sanity failure. A reason text is supplied to describe the error.), (Recommended Action: No manual recovery action required. The host VM will be automatically reloaded.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VEEA-4-BCMDPA_L1_PORT_UNSUPPORTED_PFC_ON_LLFC_ENABLED_INTF ### Response: (Severity: 4), (Category: PLATFORM), (Description: PFC and Flowcontrol co-existance is not supported. If PFC is enabled on a flowcontrol enabled interface, we dont reject the config but PFC is not enabled in Hw and wont work as desired.), (Recommended Action: Unsupported config, fix config. For PFC to work remove flowcontrol config and remove/readd PFC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-7-LOCK_WRONG_COUNT ### Response: (Severity: 7), (Category: OS), (Description: This is a debug message that is not compiled into a customer version of the code. The lock list was corrupted.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVM-3-EVM_CONTEXT ### Response: (Severity: 3), (Category: OS), (Description: Event-manager is unable to get the context from the given evm. There could be systemic problems and the process will attempt to recover with a crash.), (Recommended Action: This is an internal error and should be reported to TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: T1E1_LNM-3-MAJWARNNOISE ### Response: (Severity: 3), (Category: L2), (Description: Noise on the link identified in the message has either crossed or fallen below the threshold value configured by the user for major warning level on this controller. Video or voice quality may be affected if noise is above the configured threshold.), (Recommended Action: This link requires administrative attention. If noise is at or above the configured threshold, this may require removing/replacing this controller from service. If noise is below the configured threshold, the administrator may choose to put this link back into service or wait until noise has fallen below minor-warning level threshold.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMA_TP-3-ETMM_ITER_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Internal error has occured.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_SW_IMAGE_CORRUPTED ### Response: (Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBMA-3-SVC_ERROR ### Response: (Severity: 3), (Category: OS), (Description: A service API failed and error is displayed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-3-CTRACE_SERVER_INIT_FAILURE ### Response: (Severity: 3), (Category: TOPOLOGY), (Description: During system initialization trace server failed to initialize.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: WDMON-3-HOSTOS_HEARTBEAT_PUNCH_ERROR ### Response: (Severity: 3), (Category: INFRA), (Description: Heartbeat exchange with Host OS failed. Card will reload if the system is unable to correct this condition on its own.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-5-OOR_GREEN ### Response: (Severity: 5), (Category: PLATFORM), (Description: Device has come out of severe resource constraint state), (Recommended Action: Please collect the DPA resource information (show controller npu resources all location all). Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CAIBIST-3-DEBUG_REGISTER_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: Debug register has failed, this may be a program level error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-OPTICS_PHY_SERDES_FAULT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Serdes signal fault detected/cleared between optics and phy.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_ENCAP_DB-2-NH_NOTFOUND_ERROR ### Response: (Severity: 2), (Category: PLATFORM), (Description: nh not found in avl tree), (Recommended Action: The following needs to be collected and DE team to be contacted. show encap-id platform egress-db all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-7-ERR_DEBUG_REG ### Response: (Severity: 7), (Category: FABRIC), (Description: The Fabric driver was unable to register with the debug. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_RETRY_EXCEED_PROTECT ### Response: (Severity: 4), (Category: L2), (Description: After attempting to initialize the Protect module a number of times, the retry limit has been exceeded. The cause of the failure is very likely to be some external communication failure - so check for evidence of this. The process will exit and be restarted automatically so no futher action is needed for Bundle Manager to retry.), (Recommended Action: Check that other processes are not reporting communication errors, as this is likely to be a general communication problem. The Bundle Manager process has exited and will be restarted, so no action is needed, though unless the root problem is resolved the process will still not be able to startup.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-ERR_UNSUPPORTED_GROUP ### Response: (Severity: 3), (Category: SECURITY), (Description: RADIUS does not support command authorization and command accounting.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2VPN_PWHE-4-EA_ERR_INIT ### Response: (Severity: 4), (Category: L2), (Description: The PWHE EA process failed to initialize a critical component. The process cannot proceed and will restart to recover.), (Recommended Action: The process should recover automatically and no further action is required. If problem persists, it is suggested to collect 'show tech-support l2vpn' and 'show running-configuration' and contact Cisco TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC-3-GET_CONTEXT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: An error occured while trying to get context.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-4-BACKUP_NOT_READY_ALARM ### Response: (Severity: 4), (Category: HA), (Description: Set: When the backup process groups remain in not ready state for a prolonged period. Cleared: When the card where the backup process groups are located is removed, reset or goes ready.), (Recommended Action: Use show redundancy to see not ready conditions. If alarm persists, collect show redundancy trace location all, show redundancy, and show logging and contact customer service.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PVSTAG-4-PREEMPT_TIMER_FAIL ### Response: (Severity: 4), (Category: L2), (Description: A failure occurred while trying to start the pre-empt delay timer for the sub-interface specified in the message. As a result, any PVSTAG or PVRSTAG VLAN instances for VLANs matched by that sub-interface will use the normal values, and not the startup values, when sending BPDUs. This may cause peer devices to forward traffic on those VLANs to this device, before this device is ready to accept it. As a result, traffic may be dropped for a short period of time.), (Recommended Action: No action is necessary; the system will recover automatically once the full forwarding state has been recovered.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_RX_ALIGN_LOSS_3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Rx alignment loss on XAUI to NPU-1 interface on bridge instance-3.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XR_DIAG-3-FAB_SRCC_FAILURE ### Response: (Severity: 3), (Category: DIAG), (Description: The diagnostic test for fabric SRCC has detected an error. SRCC allows for the test cells to specify an exact route through the fabric based on IngressQ physical link number and each of the S1, S2 and S3 ASICs physical link numbers. The test is capable of potentially isolating a problem to a single link and/or ASIC.), (Recommended Action: Collect the console error messages exactly as it appears on the console and call cisco support engineers with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-3-RX_PKT_LEN_ERR_FIA10 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Packet length error FIA 10 interface.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-NH_TO_RIB_ADDR ### Response: (Severity: 3), (Category: ROUTING), (Description: A software error has occurred whilst trying to convert nexthop into RIB address using the gateway AFI.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-ING_L4_ARRAY_OFLOW_0 ### Response: (Severity: 2), (Category: PLATFORM), (Description: L4 array overflow on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TP_SW-4-TP_LXC_RESTART_MSG ### Response: (Severity: 4), (Category: PLATFORM), (Description: This message indicates that TP-LXC is restarted), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_HT0_CRC ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an HTDP CRC error on the HT0 interface.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-RCV_REGISTER ### Response: (Severity: 4), (Category: L2), (Description: After a system event, CFM was requested to re-register to receive packets on all the interfaces where it is enabled, and to re-program the offload service for sending and receiving CCMs for all offloaded MEPs, but one or both of these operations failed for some interfaces. CFM packets may no longer be sent and/or received on the affected interfaces.), (Recommended Action: If the error persists, it may be cleared by restarting the cfmd process on the node where the error is occurring.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-AIS_GEN_ERROR ### Response: (Severity: 3), (Category: L2), (Description: A failure occurred when attempting to generate or disable AIS messages for a number of local MEPs. This event was triggered by either a change within the network (e.g. to a remote MEP or to an interface state) or a change in configuration (e.g. a CoS bit or AIS transmission interval change). This may result in AIS being sent at the wrong level or interval, no AIS being sent at all, or AIS being sent when it should not be. If the error persists, CFM may not operate correctly.), (Recommended Action: If the error is the result of a configuration change, remove and reapply the configuration. If this does not work, or the error was triggered by a change in the network, the error may be cleared by restarting the cfmd process on the node where the error is occurring, or shutting down and re-enabling any affected interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-2-RESET_ON_I2C_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: This message indicates that the I2C server on the specified node encountered the specified failure. Shelfmgr will attempt to reset the board which sends the alarm.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GETMEDIA-4-INVALID_PARM ### Response: (Severity: 4), (Category: MEDIA), (Description: An application is passing an invalid application type parameter to get the storage media), (Recommended Action: It will be a harmless message if application retries with right parameter later or defaults to a right device. Report this message, console log and show media output to TAC if router malfunction.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_8_LOW_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK laser temperature less than or equal to the low temperature alarm threshold. The CPAK is the pluggable optics on the line cards. The temperature threshold values are read from the CPAK.), (Recommended Action: The system detected a low temperature threshold crossing which normally won't affect any service. Monitor the system to see if the condition clears. Generally no action needs to be taken for this condition and is more informational. If any service is affected, check the device is properly inserted. Replace the CPAK with working one (if any). Check all the FPDs are upto date using 'show hw-module fpd location all'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory', 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_PIFIB-7-ERR_DEBUG_INIT ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when initializing debug. The facility to debug the component may not work.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STANDBY-4-WARN_BADAUTH ### Response: (Severity: 4), (Category: IP), (Description: The peer HSRP router has mismatching authentication settings. The authentication string in the HSRP packet did not match the locally configured value. Consequently this peer is ignored.), (Recommended Action: Check the authentication settings on the local device and the peer device(s)) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-3-MRIB_CONN_ERR ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace mrib error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace mrib error output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp trace error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: vlea-3-NO_STATS ### Response: (Severity: 3), (Category: L2), (Description: The VLAN EA process encountered an error while registering with the statistics server process. No VLAN sub-interface statistics will be gathered on the given linecard.), (Recommended Action: This error message indicates a problem with in the statistics server process on the RP, or with the communications between the linecard and the RP. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_SYSDB ### Response: (Severity: 4), (Category: L2), (Description: PPP MA encountered an error using the SysDB service. The error message describes what operation has failed and why it failed. The most likely reason for this is a connection problem with the SysDB server, but the error could also be caused by low memory resources or programming error.), (Recommended Action: Consider restarting the PPP MA process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: 10GE_PLIM-2-XGXS_RX_SYNC ### Response: (Severity: 2), (Category: L2), (Description: The XGXS Rx Lanes failed to synchronize after a Xenpak OIR or Link Flap.), (Recommended Action: Try to shut/no shut the port. If the MAC does not get enabled, then A physical OIR of the Xenpak device will be needed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2RIB-3-ERR_LOCAL_TO_REMOTE_STATIC ### Response: (Severity: 3), (Category: L2), (Description: Statically configured MAC address on remote router is already used by a locally learnt host. Static configuration on remote router will take precedence. All traffic destined to MAC address will be forwarded using static MAC configuration on remote router.), (Recommended Action: Please assign different MAC address to local host or change statically configured MAC address on remote router.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VFW-4-FWC_REMOVE_ATTACHMENT ### Response: (Severity: 4), (Category: SECURITY), (Description: The Firewall Controller has tried to remove an attachment as a result of a notification from RSPP, but has failed to do so. This may result in inconsistent data in the firewall controller and unexpected behaviour.), (Recommended Action: If the firewall controller behaves unexpectedly, the problem may be resolved by restarting it using the 'process restart' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVPN-3-UNSUPPORTED_MAC_LENGTH ### Response: (Severity: 3), (Category: L2), (Description: EVPN only supports MAC address length of 48 bits.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-5-HOMEPATH_STATE ### Response: (Severity: 5), (Category: ROUTING), (Description: The homepath state of lsp has changed for this tunnel.), (Recommended Action: None. This is a solicited message (by 'logging event lsp-status homepath-state' \ interface configuration) and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR-2-ETHSVR_INIT_FAILED ### Response: (Severity: 2), (Category: PLATFORM), (Description: Eth Server Initialization failed. Eth Server will be restarted to overcome transient failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_SYSDB_ACCESS ### Response: (Severity: 3), (Category: ROUTING), (Description: An unexpected error occurred while accessing the specified SysDB item. This may be due to resource starvation or an internal software programming error.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*. The IS-IS process must be restarted before it can function correctly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CONTROLLER_XC-3-PROC_INIT_FAILURE ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: A failure occurred during initialization with a necessary service for the process. The process is unable to run.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ASR9K_LICENSE-6-UPDATE_COMPLETED ### Response: (Severity: 6), (Category: LICENSE), (Description: Entitlement update from consumption model is completed.), (Recommended Action: 'INFO') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RSP_CPUCTRL-1-PCIE_TX_FIFO_SBE ### Response: (Severity: 1), (Category: PLATFORM), (Description: Error reported by the cpu control fpga), (Recommended Action: Check and upgrade FPGAs on the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2VPN_FGID-6-LTRACE_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the ltrace module in the platform L2VPN component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-ACP_DIKE_TO_NBR_CREATED ### Response: (Severity: 6), (Category: SERVICES), (Description: 'Autonomic Network Control plane - DIKE tunnel ' 'established to neighbor'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PRM_SERVER-4-MISC_ADD_MOD_DEL_FAIL ### Response: (Severity: 4), (Category: PLATFORM), (Description: An attempt to create/modify/delete sw/hw object failed.), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-6-SUDI_AVAILABLE ### Response: (Severity: 6), (Category: SERVICES), (Description: 'Secure unique device identification number ' 'is available on the device'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMART_LIC-3-CERTIFICATE_VALIDATION ### Response: (Severity: 3), (Category: LICENSE), (Description: The ID-Cert validation failed.), (Recommended Action: Please check the smart agent syslog file for more information. Please turn on the smart agent debug mode (CLI command: license smart debug enable) and retry again for additional information. Please check if the ID cert expiration date has been reached.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_3_LOW_TX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.), (Recommended Action: Verify that the device is properly inserted. Replace the CFP with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-RACK_TO_STR_FAILED ### Response: (Severity: 3), (Category: MGBL), (Description: Nodeid conversion API has failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SMGR-3-MSG_SEND_PULSE ### Response: (Severity: 3), (Category: OS), (Description: (CJ-FIXME)SM process tried to send a pulse to the clients channel using MsgSendPulse api and encountered a failure.), (Recommended Action: Collect system log information for the reported service and pid. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XCVR-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message from the XCVR, it indicates that something has gone wrong internally in the XCVR.), (Recommended Action: File a DDTS) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-XAUI_0_LQ_OFLOW_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Queue overflow error on XAUI 0 LQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TMPL-7-INTERNAL ### Response: (Severity: 7), (Category: SUBSCRIBER), (Description: An unexpected internal error occurred in the template manager subsystem.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_SSE-3-ERR_ISB_INIT ### Response: (Severity: 3), (Category: L2), (Description: bfd_agent encountered an error while initializing its interface database information. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will reload the MSC.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA-1-OOR_RED ### Response: (Severity: 1), (Category: PLATFORM), (Description: This is a severe error message in the DPA module to indicate high usage of DPA resources.), (Recommended Action: Please collect the DPA resource information (show controller npu resources all location all). Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-4-CONFIG_ERR ### Response: (Severity: 4), (Category: FABRIC), (Description: Ingressq has various queues that are used by Ingress ASICs to send specific stream of traffic. These queues are specifically configured before they are used to forward traffic. Ingressq recived a few packets in queues that were misconfigured or not configured at all. The driver will automatically try to recover from the condition.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NP-4-CONFIG_INIT ### Response: (Severity: 4), (Category: PLATFORM), (Description: Initialization cannot be completed because sysdb is not ready to accept registrations.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CEM_PLATFORMS-2-ERR_INT ### Response: (Severity: 2), (Category: L2), (Description: Error in cem operation.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_COM_NETIO-7-DEBUG_REGISTER ### Response: (Severity: 7), (Category: OS), (Description: An error was returned when registering debug.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-3-ASIC_CS_INFO ### Response: (Severity: 3), (Category: OS), (Description: An unexpected error occurred.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_CPP_PM_SHM-3-FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: Shared memory access operations like init,open or bind might have failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show shmwin trace < > command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show shmwin trace < > output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show shmwin summary < > command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show shmwin summary < > output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show shmalloc trace < > command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show shmalloc trace < > output, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-3-DB_CORRUPT ### Response: (Severity: 3), (Category: LICENSE), (Description: This message occurs when the license manager detects corruption in the license database that cannot be repaired. The license database will be cleared and implicit evaluation licenses will be available for 90 days.), (Recommended Action: If a backup of the license database is available it can be restored with the 'license restore' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PEX8508-3-CORR_ECC_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PCIE device correctable ECC error), (Recommended Action: This error is a momentary error and software should be able to correct it. If the issue persists please, contact your technical support representative with the gathered information. No action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POS-2-NOT_MAX_PORT ### Response: (Severity: 2), (Category: L2), (Description: While enabling the POS ports, all ports were not enabled.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - Check for memory usage, this is a very corner case) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-IM_CAPS_UNKNOWN ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS has received an IM message referring to a capsulation number that IS-IS does not recognized and is not able to handle. This is an internal programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-NPU_1_SCH_MEMP_ERR_2 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Scheduler Hang, Sram or egress mid-fifo parity error on NPU-1 interface on bridge instance-2.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSA-3-ERR_CLEAR_FSTATS_ALL ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric Plane Statistics CLI encountered an error in trying to clear the fabric plane statistics as a result of sysdb call failure. This software error will cause the following fabric plane statistics getting appended to the previous ones. No other system functionality will get affected due to this.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_UNREPLICATE ### Response: (Severity: 4), (Category: L2), (Description: When attempting to unreplicate the bundle from the specified location(s), the unreplication operation failed. Some hardware resources may continue to be used for the bundle on the specified location(s). It is also possible that there could be a problem replicating the bundle to those locations again if a new member is added.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-3-FSM_ROOT_TIMER_CREATE_FAILURE ### Response: (Severity: 3), (Category: PLATFORM), (Description: This message indicates that Shelf Manager was unable to initialize the timer infrastructure required to monitor the booting of nodes.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_LPTS_PIFIB-3-CONFIG_POLICER_PARAMETER_INVALID ### Response: (Severity: 3), (Category: OS), (Description: There is an invalid parameter after a keyword in a policer definition. The policer may be assigned default characterstics.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB-4-INVALID_FAB_MODE ### Response: (Severity: 4), (Category: FABRIC), (Description: This indicates that the fabric card in the mentioned slot is incompatible with the admin configs done for the plane participated by this card), (Recommended Action: To fix the issue please change the fabric card or modify the admin config for this plane) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_IPV4_MRIB-3-CHKPT_REGISTER ### Response: (Severity: 3), (Category: ROUTING), (Description: The MRIB encountered error while registering to existing table. This will result in failure of registering the platform dependant MRIB process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LICMGR-4-LICENSE_RMA_WILL_EXPIRE ### Response: (Severity: 4), (Category: LICENSE), (Description: Licenses for the specified feature which were installed using the given chassis serial number will be removed in the time indicated unless the chassis is reconnected from the system. This message appears even if the removed licenses are not active.), (Recommended Action: Confirm that sufficient licenses remain on the system signed with the chassis serial number of available chassis. If necessary, obtain new licenses for the feature and install them with the 'license add' command. If there are sufficient licenses remaining signed with available chassis serial numbers, the message can be stopped by using the 'license remove' command to remove the licenses associated with the specified chassis.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCE-7-CSPF_FALLBACK ### Response: (Severity: 7), (Category: OS), (Description: A disjoint path couldn't be found.), (Recommended Action: Check network redundancy.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MBMA-3-PLUGIN_INIT ### Response: (Severity: 3), (Category: OS), (Description: MBMA plugin initialization failed.), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DMAC_LIB-4-UNEXPECTED ### Response: (Severity: 4), (Category: PLATFORM), (Description: An unexpected condition encountered. This is not necessarily an error, but may help with debugging other problems elsewhere.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIB_IPV4-3-UPDATE_ERR ### Response: (Severity: 3), (Category: L2), (Description: An updation error has occured for IPv4 Forwarding Information Base.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2RIB-3-ERR_STATIC_TO_REMOTE ### Response: (Severity: 3), (Category: L2), (Description: Remote host cannot be assigned a MAC address which is configured as a static MAC address. Statically configured MAC address takes precedence. All traffic destined to MAC address will be forwarded using static MAC configuration.), (Recommended Action: Please assign different MAC address to remote host or change statically configured MAC address.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FR_SOCKET-3-SEND_ASYNC ### Response: (Severity: 3), (Category: L2), (Description: The fr_socket process failed to send asynchronous pulse to Frame-relay socket Event manager. This may cause disruption in packet read.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XFP-2-HIGH_TEMP_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected an XFP temperature greater than or equal to the high temperature alarm threshold. The XFP is the pluggable optics on the line cards. The temperature threshold values are read from the XFP.), (Recommended Action: Verify that the device is properly inserted, the fan is operational, and empty slots have filler cards installed. Check the 'show environment temperatures'. If the system temperature is normal then replace the optics with working one (if any). If the system temperature is not normal, verify the fan speed and make sure installation is compliance with 'Cisco ASR 9000 Series Aggregation Service Router Hardware Installation Guide'. Check specifically the 'Chassis Air Flow Guidelines' and 'Rack-Mounting and Air Flow clearance guidelines'. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all', 'admin show inventory' and 'show environment temperatures' and 'admin show environment fans'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the configuration rollback feature in IOS XR? ### Response: The configuration rollback feature in IOS XR allows you to revert the configuration to a previously committed state. This is useful for quickly recovering from configuration errors or rolling back to a known good configuration. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOCALD-3-MSG_SIZE_ERR ### Response: (Severity: 3), (Category: SECURITY), (Description: An internal error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-3-AIS_GEN_TIMER ### Response: (Severity: 3), (Category: L2), (Description: An error occurred while starting or restarting the AIS generation timer. No further AIS messages will be sent for MEPs/interfaces in this service/bridge domain.), (Recommended Action: Unconfigure AIS generation on the service or interface, then reconfigure it. If the problem persists, it may be possible to recover by restarting the 'cfmd' process on the node where the problem occurs.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MFR_MA-3-ERR_SYSDB_BIND ### Response: (Severity: 3), (Category: L2), (Description: SysDb bind API fails for some reason. This should be analyzed. first %s - Type of SysDb bind second %s - Error string), (Recommended Action: Contact support with the required_info.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FM-3-FAULT_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Fault Detected), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPP_MA-4-ERR_IPV6CP_OPTS_INCONSISTENT ### Response: (Severity: 4), (Category: L2), (Description: PPP MA has negotiated inconsistent IPv6CP options. The message details which options are inconsistent. IPv6CP will be brought up, but the inconsistencies could cause problems. The most likely reason for this is a misconfiguration, either locally or on the peer.), (Recommended Action: Consider changing the relevant configuration either locally or on the peer.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LOADPATH_UPGRADE-7-PACKAGE_SUPPORTS_NO_NODE_TYPES ### Response: (Severity: 7), (Category: INSTALL), (Description: Instructions in package list no node types for which the package can be activated.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-INSTALL_OPERATION_FAILED ### Response: (Severity: 6), (Category: INSTALL), (Description: An install operation failed. Use 'show install log detail' for more details.), (Recommended Action: Please use 'show install log detail' to obtain more information about the failure and take corrective actions if necessary. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What are the different levels of the MPLS VPN CSC feature? ### Response: The different levels of the MPLS VPN CSC feature are\n- CSC-1: Customer carrier uses IP to transport MPLS VPN services\n- CSC-2: Customer carrier uses MPLS to transport MPLS VPN services, but does not use labels (IP+BGP)\n- CSC-3: Customer carrier uses MPLS to transport MPLS VPN services, and uses labels (MPLS+LDP)\n- CSC-4: Customer carrier uses MPLS to transport MPLS VPN services, and uses labels with BGP label distribution (MPLS+BGP labels)\n- CSC-5: Customer carrier uses MPLS VPN to transport MPLS VPN services (MPLS VPN+LDP+BGP labels)\""\n <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-MUTEX_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: A error occurred in the initialization of the primitives used for thread synchronization. This is most likely a system error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospfv3 trace all - show running-config - show configuration failed - show configuration history 5 - show commit changes - show process ospfv3 location all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCDS-3-ERROR ### Response: (Severity: 3), (Category: OS), (Description: Required functionality failed or returned an error), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_PM_CS-6-INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The Platform Manager info for some action taken.), (Recommended Action: No action is required) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGRV2-2-NODE_REBOOT_RECEIVED ### Response: (Severity: 2), (Category: PLATFORM), (Description: The indicated node notified shelfmgr about its software reboot with the reboot reason and cause code.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SYSDB-4-SC_COMMITTRANS ### Response: (Severity: 4), (Category: SYSDB), (Description: An error occurred invoking a SysDB function. The details are in the error string.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ether_spa_plugin-6-UNSUPPORTED_OPTICS ### Response: (Severity: 6), (Category: L2), (Description: The Transceiver module inserted in the specified port is not supported.), (Recommended Action: Collect the PID, Vendor Information of the Transceiver from the CLI 'show controllers TenGigE<>/<>/<>/<>' and contact TAC.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPA_8P_GE-3-PORT_DEL_TIMEOUT ### Response: (Severity: 3), (Category: L2), (Description: Port deletion failed to complete within the timeout period.), (Recommended Action: Upon seeing this message collect the trace log via 'show plim ether trace error location <>' 'show plim ether trace info location <>' 'show tech-support ethernet ' and send them to the Engineering team.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-BINDING_FORCE_DELETE ### Response: (Severity: 3), (Category: IP), (Description: Binding is forcefully deleted.), (Recommended Action: Note the Parent-Event-Id from the error message. Look for the error message (parent error message) with Event-Id same as the Parent-Event-Id of this error message to know the reason of why this binding is forcefully deleted.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-2-RELOAD_FAILED_NODES ### Response: (Severity: 2), (Category: INFRA), (Description: A user requested reload-failed-nodes action is about to take place which will result in failed nodes being reloaded and held down until the current install transaction has completed. When the install transaction is complete these nodes will be reimaged so that all nodes in the system are running consistent software.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CTRLIO-3-DLL_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: 'Process failed in opening dll.' 'ISSU operation will continue without any error.'), (Recommended Action: 'ISSU manager will retry opening dll after sometime.' 'If the issue persists ' 'contact tac with 'show tech-support issu'.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EINT_NETIO_DLL-3-ATTACH_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: EINT was not able to attach to plim interface .), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-3-LWA_REM_FAIL ### Response: (Severity: 3), (Category: SECURITY), (Description: Failed to remove a username from the LWA DB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELO-6-MISCONFIGURED_INTERFACE ### Response: (Severity: 6), (Category: L2), (Description: A profile can be configured that has configuration parameters that are not supported for all interfaces on the router. If that profile is later attached to an interface for which not all its values are supported, this message is generated. The interface will use the default values for any parameter that is out of range but the show commands and OAM PDUs will contain the configured value from the profile rather than the operational value. The configuration parameters that may not be supported are support for remote loopback and support for link monitoring events. Further, the window size of a link monitor event must be a multiple of the interface's statistics' poll interval.), (Recommended Action: Nothing need be done if the default values are acceptable for the invalid parameters & the incorrect values in show commands & OAM PDUs do not affect operation. Otherwise, modify the profile to contain only configuration that is supported for the interfaces to which it is attached, or use an alternate profile for this interface.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HTTP_CLI-3-SYSDB ### Response: (Severity: 3), (Category: MGBL), (Description: A SysDB operation carried out by the HTTP CLI Agent returned unexpected results.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HFR_TUNNEL_EA-3-ERROR_PARAM ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an error message in the CRS platform specific code software to indicate some problem with the code. %s - indicates the reason for the failure.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-3-TRANSPORT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: CRS: This indicates that there is a problem with control ethernet cables or switches to that node. C12k: This indicates that there is a problem with MBUS communication to that node.), (Recommended Action: CRS: Check the control ethernet connectivity to the node. (Check if the cables are okay and also if the switch is operating normally). C12K: If the error persists for a long time, please check the MBUS communication to the node. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIBSNMP-3-NOMEM_FOR_INIT ### Response: (Severity: 3), (Category: SNMP), (Description: Not enough memory was available for snmpd to set up its internal data structures.), (Recommended Action: Try stopping some running processes, or wait awhile before restarting snmpd. If the problem persists after several tries, please contact your customer support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP-4-RECONNECT_FAILED ### Response: (Severity: 4), (Category: L2), (Description: STP has encountered an error while attempting to resynchronize its data with Interface Manager. The process will restart automatically to correct the problem.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_MESSAGING-7-PTHREAD_FAILURE ### Response: (Severity: 7), (Category: HA), (Description: A call to a Posix Pthreads function failed.), (Recommended Action: Collect system log information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: protect_debug-7-DUMP_HANDLE_HDR ### Response: None <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MCASTSN-3-NET_FAIL ### Response: (Severity: 3), (Category: L2), (Description: This error indicates that the igmp snooping process failed to send out a packet or a pulse.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp snooping trace error verbose command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp snooping trace error verbose output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show igmp snooping trace error command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show igmp snooping trace error output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PTP-4-PORT_NUM_CHECKPOINT_READ_FAIL ### Response: (Severity: 4), (Category: L2), (Description: PTP was unable to read port number information from checkpoint.), (Recommended Action: The system should recover, no further action should be required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RT_CHECK-3-MGD_TIMER ### Response: (Severity: 3), (Category: OS), (Description: A call to a mgd timer interface failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_SRVR-6-ASIC_RESET_REASONS ### Response: (Severity: 6), (Category: FABRIC), (Description: This message is seen when fabric ASICS are being reset. The status reported here provide information about the reason for the reset.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPIO-4-INV_PKT ### Response: (Severity: 4), (Category: L2), (Description: A malformed packet was detected in a batch passed to the SPIO platform libraries.), (Recommended Action: If any problems are seen, they may be rectified by restarting the affected process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_MGT_CV_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-1 MGT code violation on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PFILTER_EA-3-INIT_ERROR ### Response: (Severity: 3), (Category: L2), (Description: The pfilter_ea process failed to initialize. This pfilter_ea process programs the 'packet filter' security access control list in the hardware. If the pfilter_ea process fails to initialize, the access control list cannot be programmed into the hardware. %s - indicates the reason for the initialization failure. %s - is the decoded error reason.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process pfilter_ea location 0/x/cpu0' to verify that the process is up and running. If it is still non-operational, try doing 'process restart pfilter_ea location 0/x/cpu0'. Collect all debug information if the process is continually restarting 'debug pfilter-ea all' (during the process restart). If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POLICY_REPOSITORY_DYNREG-3-AP_ADD_FAIL ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered as the node location was being added to the attach point item. This will prevent the successful registration for this attach point and will leave this configuration space unverified with respect to policy configuration.), (Recommended Action: Restart the policy_repository process and check for re-occurence of issue If problem persists, the please contact support team) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPU-2-MOVE_TO_RESET ### Response: (Severity: 2), (Category: L2), (Description: This indicates a hardware memory issue with the line card. The line card will be put to IN-RESET state to avoid further boot-up.), (Recommended Action: RMA of the linecard would be needed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_QOSEA-3-BANDWIDTH_RATIO ### Response: (Severity: 3), (Category: QOS), (Description: The bandwidth ratio is invalid at this level. The message will provide further details on the error.), (Recommended Action: Please adjust the bandwidth parameters in the policy map.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-7-SRV6_DEINIT_FAIL ### Response: (Severity: 7), (Category: ROUTING), (Description: An error occurred whilst deinitialising the SRv6 module. This could be caused by failure to release resources or by errors when calling the sidmgr.), (Recommended Action: This message is informational.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SP1_INTR_SLICE5_WORD_OUTSYNC_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SP1_INTR_SLICE5_WORD_OUTSYNC interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-SRGB_PLATFORM_LIMIT_EXCEEDED ### Response: (Severity: 4), (Category: ROUTING), (Description: Platform does not support the configured segment routing global block range.), (Recommended Action: Change the segment routing global block configuration to avoid exceeding the platform maximum supported label value.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-STR_NEGO_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, expected error information in case of transition between CGV6 and CDSTV/CDSIS roles on an ISM LineCard.), (Recommended Action: Please collect the console logs and following CLI output show platform show platform summary loacation show running-config | i hw-module service show install active show install inactive show services role location show services role registered show services role trace agent location show services role trace server location If the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_IPV6_EA-3-ERROR2 ### Response: (Severity: 3), (Category: PLATFORM), (Description: A runtime error occurred in IPv6 EA. Here is a list of possible reasons for this message (not all-inclusive). - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid. - Resource limitations. This condition indicates a problem where the software has limited resources to operate on.), (Recommended Action: Please collect the console log and the CLI output. show cef ipv6 show memory summary show cef ipv6 location <> show memory location <> show cef ipv6 trace location <> show cef platform trace all all location <> show tech cef show version show install active summary Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TLU-4-ADDR_VALIDATE_FAILED ### Response: (Severity: 4), (Category: PLATFORM), (Description: An error was encountered while validating tlu address range), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-2-EGR_NPH_LEN_0_1 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Invalid egress NPH length detected on xaui-0 bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OTN_FRAMER-6-FMEA_ASIC_RESET ### Response: (Severity: 6), (Category: OS), (Description: DIGI Asic Reset Triggered during FMEA.), (Recommended Action: Informational only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVEDGE_DATA-6-IRL_1SLOT ### Response: (Severity: 6), (Category: PLATFORM), (Description: Recommendation for better IRL resiliency), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-QCR_PGAR_CURR_MEM_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected PGAR Current memory error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_CPUCTRL-0-FPGA_HW_ACCESS_FAIL ### Response: (Severity: 0), (Category: PLATFORM), (Description: LC CPU controller driver detected FPGA access failure. This error message is thrown after observing consistent fpga access failures, one of the possible reason could be PCIE link down between PCIE switch and FPGA.), (Recommended Action: Reload the LC that has the problem atleast three times. If problem persists, contact support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-CONFIG_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: This is an informational message in the Platform FIB to indicate that platform layer identified an unsupported configuration with vrf), (Recommended Action: Please validate your vrf configuration - if you exceeds vrf scale and number of vrf is more than 254 and if you have not configiured CLI (hw-module tcam fib ipv4 scaledisable) then you can see this error. it is a case of platform scale limit and can not be tracked by PI easily. Collect console log, FIB traces (show cef trace loc <>), FIB platform trace (show tech cef platform ) if the error does not go away even after reloading the box after fixing vrf scale. Also notice if the error message is transient or persistent. Notice if required critical information like inventory-data, ASIC devices, os-support has any errors or blocked process. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RPL-3-INTF_ERROR ### Response: (Severity: 3), (Category: ROUTING), (Description: A software error has occurred in rpl_ma thread code.), (Recommended Action: Try restarting the rpl ma process using the 'process restart ipv6_rpl_ma' cli. If problem persists contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the role of the install prepare clean command in IOS XR? ### Response: The 'install prepare clean' command is used to clean up the installation storage area by removing any incomplete or aborted installations. This helps to free up disk space and ensures a clean state for future installations. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV6-4-SYSDB_CREATEITEM_FAILED ### Response: (Severity: 4), (Category: IP), (Description: Failed to create an item in SysDB.), (Recommended Action: Restarting the process may fix the issue.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BFD_SSE-3-ERR_CCI_INIT ### Response: (Severity: 3), (Category: L2), (Description: BFD SSE was unable to initialize CPU Controller interface for sending/receiving BFD packets or messages via PDMA. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will reload the MSC.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MOFRR_FLOW-3-DETECT_ACTIVE_PRIM ### Response: (Severity: 3), (Category: ROUTING), (Description: LC control plane detected that traffic is already coming on primary path. Then set the HW watchdog of ingress NP to monitor traffic loss event on the path instead of monitoring traffic activity.), (Recommended Action: It is a self-recovery detection. There is no extra action needed.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FGID_AGG-3-ERR_DEBUG_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: The FGID Aggregator was unable to initialize debug. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PIM-3-ERR_LIST ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRID_CLIENT-7-SEND_FAIL ### Response: (Severity: 7), (Category: PLATFORM), (Description: gsp sync message from grid client to grid server has failed due to one of the following reasons: 1) GSP is failied to deliver the message to grid server within timeout time. 2) GSP group is in orphan state and replies are not valid. 3) Reply is not from actual grid server. 4) Grid server fail to process client request.), (Recommended Action: Node reload is only option to recover from this failure otherwise encap failures will be seen. it's a fatal condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS_EA_VERIFY-6-FAILED ### Response: (Severity: 6), (Category: QOS), (Description: The QoS EA policy verification encountered the specified error. This may happen because the QoS policy is invalid and cannot be applied successfully.), (Recommended Action: Check the output of 'show config failed' and correct the qos policy appropriately.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EVM-4-CHAN_DISC ### Response: (Severity: 4), (Category: OS), (Description: An LWM channel disconnect call failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. This is an internal error and should be reported to TAC. The client process for the failed fd is having an issue disconnecting from its server.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: STP_IO-3-TIMER_FAILED ### Response: (Severity: 3), (Category: L2), (Description: An error has occurred processing one or more timer events driving the MSTP engine. The process has restarted to correct this issue.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_HEAP-7-SEGMENT_RENAMED ### Response: (Severity: 7), (Category: HA), (Description: A corrupted CDM segment has been renamed for later analysis.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SERVICE_LAYER-3-BFDS_DROPPED ### Response: (Severity: 3), (Category: ROUTING), (Description: A synchronous BFD operation request received when server initialized in asynchronous mode or vice versa; or when server is not ready.), (Recommended Action: Controller and/or agent must ensure that BFD operation requests are sent only in the mode specified by the client initialization message and server is ready. If message is still seen after meeting these conditions, contact Cisco for support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ERR_THREAD_CREATE ### Response: (Severity: 3), (Category: MGBL), (Description: 'The call to pthread_create failed. The error text is displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PPPOE_MA-4-ERR_MEM_ALLOC ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The process failed to allocate memory for the specified resource.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ENVMON-3-FANTRAY_ALARM_CLEAR ### Response: (Severity: 3), (Category: PLATFORM), (Description: All fans on indicated fan tray operating at the set RPM.), (Recommended Action: None required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-0-INT_HT1_INVALID_CMD ### Response: (Severity: 0), (Category: PLATFORM), (Description: QFP-CPU Bridge detected an invalid command on the HT1 HTDP interface. This means that the HT host core has received a non-posted write command. These packets are not supported and behavior is undefined after this type of packet is received.), (Recommended Action: Save log file and report this error. If line card fails to auto-reset, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_12IN1-6-DCE_CLOCK_RATE_ROUNDING ### Response: (Severity: 6), (Category: L2), (Description: The DCE transmit clock rate has been rounded down to the next best value supported by the hardware. This is not an error but rather a informational message to explain the reduced clock rate.), (Recommended Action: No action required. This is a informational message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: AN-3-ACP_IPSEC_TO_NBR_FAILED ### Response: (Severity: 3), (Category: SERVICES), (Description: 'Autonomic Network Control plane - Failed to create IPSEC ' 'tunnel to neighbor'), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-3-TABLE_CREATE ### Response: (Severity: 3), (Category: ROUTING), (Description: An error occurred when creating the table context for the shown VRF name, AFI, SAFI. As a result table can't be activated.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-XAUI_1_MGT_CV_1 ### Response: (Severity: 1), (Category: PLATFORM), (Description: XAUI to NPU-1 MGT code violation on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-6-ASIC_WRITE_ACCESS ### Response: (Severity: 6), (Category: FABRIC), (Description: This indicates a failed access to the ASIC.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_ICMP-7-SYSDB_REG_VERIFY_FAILURE ### Response: (Severity: 7), (Category: IP), (Description: IP ICMP library encountered failure in registering verifier with SysDB. Typically this error is caused if sysdb is unavailable for an extended period.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action.If does not recover contact Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VKG_BCM8705-3-IF_OPERATION_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Recommended Action: Debug message only. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISSU_DIR-3-NTFN_CONNECT_FAIL ### Response: (Severity: 3), (Category: INFRA), (Description: ISSU Director encountered an issue while handling a connection event from an ISSU Notification client.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-ZEN_BASE_ADDR_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the install label command in IOS XR? ### Response: The 'install label' command is used to assign a label to a set of packages. This label can then be used in other install commands to refer to that specific set of packages, making it easier to manage and identify them. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM-4-SPA_HW_ERR_THRESHOLD ### Response: (Severity: 4), (Category: L2), (Description: A hardware error is detected on the PLIM SPA, and the error threshold has been crossed. Software will take action as described in the error message. Device: %s - indicates the device on which the error is detected. Error: %s - description of the hardware error. Threshold of %s - the defined threshold for this error. Software action: %s - the action that software will take to try to contain or recover from the error. Recommended user action: %s - recommended action to the user.), (Recommended Action: Take the recommended user action as it is described in the error message.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-6-INSTALL_COMPLETE_PHASE_STARTED ### Response: (Severity: 6), (Category: INSTALL), (Description: The complete phase of an ISSU operation has started - another message will be output when the phase finishes.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MSDP-3-LTRACE_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_PM_TEST-3-ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: skp_pm test encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: This is just test software which the customer does not get. so there is np actiom required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LTRACE_SYNC-7-MEMORY_MAP_ERROR ### Response: (Severity: 7), (Category: OS), (Description: Memory mapping for the file failed.), (Recommended Action: Contact support.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-BFD_DELETE_UNCONFIG_FAIL ### Response: (Severity: 4), (Category: ROUTING), (Description: IS-IS failed to admin shutdown one or more sessions with the BFD server. The connection to the server will be reset in an attempt to recover from the error.), (Recommended Action: This failure may due to lack of resources. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the failure is not due to a lack of resources seek support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_14 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLIM_16P_OC48-3-DRV_INIT_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLIM driver encountered the annunciated error during the driver initialization. The System Manager process (sysmgr) will automatically respawn the (plim_16p_oc48) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MMSMLIB-3-EXIT_ON_ERR ### Response: (Severity: 3), (Category: L2), (Description: An error occurred in the PSE ASIC client library after which the client code cannot continue. This error is encountered when a client module (e.g. cli command) has difficulty retrieving information from the PSE driver. The root cause may be located in either hardware or software.), (Recommended Action: *RECUR* Copy the error message exactly as it appears on the console) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-3-CF_OVF_ERR_FIA00 ### Response: (Severity: 3), (Category: PLATFORM), (Description: Ingress MUX FPGA encountered FIA00 channel FIFO overflow error.), (Recommended Action: Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPF_RIB-3-ERR_UPDATE_DONE ### Response: (Severity: 3), (Category: ROUTING), (Description: An error was encountered in the call to ipv4_rib_batch_complete.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: cds_svr-3-MEMORY ### Response: (Severity: 3), (Category: OS), (Description: The server has failed to acquire the required amount of memory.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_LSD-2-ERR_MEM_ALLOC ### Response: (Severity: 2), (Category: ROUTING), (Description: MPLS LSD terminated due to lack of memory for a critical operation.), (Recommended Action: The system is running under very low memory condition. Collect MPLS LSD traces and restart mpls_lsd process) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-DEVICE_MOUNT_FAILED ### Response: (Severity: 4), (Category: MEDIA), (Description: The media storage card specified failed to mount due to the specified operation. The returned error code is specified.), (Recommended Action: Format media device manually. if still fails, replace media device. Contact TAC if device is unable to mount properly) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_8_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_8 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3_UV-3-ERR_SYSDB_REG_VERIFY ### Response: (Severity: 3), (Category: ROUTING), (Description: The ospfv3_uv process was unable to register with SysDB.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PARSER-3-NODEID_TO_STRING_ERROR ### Response: (Severity: 3), (Category: MGBL), (Description: Error in conversion routine.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: EMUX-1-MC_LO_OVR_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Multicast low priority fifo overflow error), (Recommended Action: Please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-0-EBS_CPP_LP_TAIL_DROP ### Response: (Severity: 0), (Category: PLATFORM), (Description: Egress Buffer and Scheduling to CPP low priority tail drop.), (Recommended Action: Reset the board.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-CHKPT_MEM_OUT_OF_RANGE ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Shelfmgr encountered unexpected checkpoint memory), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM-3-EVM_EXIT ### Response: (Severity: 3), (Category: TOPOLOGY), (Description: Code flow exited from the main EVM block.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DSC-6-WAIT_TIME ### Response: (Severity: 6), (Category: PLATFORM), (Description: Informational message notifying current DSC in system.), (Recommended Action: This is an informational message. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OFA_PLUGIN-7-OVS_DEBUG ### Response: (Severity: 7), (Category: L2), (Description: OVS debug message.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFP-3-LANE_11_LOW_RX_POWER_WARNING ### Response: (Severity: 3), (Category: PLATFORM), (Description: Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.), (Recommended Action: Verify that device and RX fiber is properly inserted. Verify that the far end is enabled and transmitting and the input attenuation is not too high. Replace the attenuator with working one (if any) to isolate bad attenuator. Replace the optics with working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MEDIASVR-4-DEVICE_FORMAT_FAILED ### Response: (Severity: 4), (Category: MEDIA), (Description: The media storage card failed to be formatted due the specified reason. The returned error code is specified.), (Recommended Action: Format media device manually, if still fails, replace media device.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SD-3-NOMEM ### Response: (Severity: 3), (Category: SERVICES), (Description: There are insufficient resources to perform some action. The error message contains more details about what action failed. In any case, services may not be operating correctly, and states may be out of sync.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Once the memory conditions have been improved, restart the Service Director process to allow it to resynchronise with its clients.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: REDCON-4-SRP_NR_REASON_UNREG ### Response: (Severity: 4), (Category: HA), (Description: An unexpected error condition encountered.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FCA-2-SFP_LNK_FAULT_ERROR_24 ### Response: (Severity: 2), (Category: PLATFORM), (Description: Port controller driver detected a TX fault on the SFP port.), (Recommended Action: In config mode, do a 'shut' and 'no shut' on port interface. If the problem persists, please OIR the SFP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TAMSVCS-3-TPM_MAX_RESTARTS ### Response: (Severity: 3), (Category: SECURITY), (Description: TAM restarted maximum number of times. Stalling or shutting down tam servivces until manual restart is initiated.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPA_MGR-3-BAD_ID_HW ### Response: (Severity: 3), (Category: PLATFORM), (Description: Hardware in the specified location could not be identified as genuine Cisco product by mpa manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTALL-3-INFRA_RESTART_FAILED ### Response: (Severity: 3), (Category: INFRA), (Description: While activating software that requires the install infra itself to restart, install processes on some nodes failed to restart. Please check the available install recovery actions.), (Recommended Action: Please obtain the output from the console or system log, and the entire output of the following commands: show tech-support install) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: HA_WD_LIB-7-NO_MEM ### Response: (Severity: 7), (Category: HA), (Description: Allocating memory failed due to a low-memory condition.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CISCOSYSTEMMIB-3-SYSDB_ACCESS ### Response: (Severity: 3), (Category: SNMP), (Description: The MIB had trouble reading from or writing to or binding/unbinding SysDB.), (Recommended Action: 'If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-7-ERR_LINK_TOPO ### Response: (Severity: 7), (Category: FABRIC), (Description: The upstream information received from idle cells on this link does not match with FSDB information.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BCM_SWITCH-3-BCM_LOG_OPEN_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: Failed to open the bcm_log file. Outputs are logged in stderr file.), (Recommended Action: Please do bcm_process restart to recover from this. 'process restart bcm_process location < >' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-CHECKPOINT_CANT_RELOAD ### Response: (Severity: 3), (Category: OS), (Description: A link found in the checkpoint file could not be created in the QSM database.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-1-IO_ERROR ### Response: (Severity: 1), (Category: FABRIC), (Description: Fabricq ASIC encountered a read or write access error or its Host Processor Interface block has gone down and come back up. The access error is classified into two classes - software or hardware. Hardware access error refers to an error at the PCI link used to connect the ASIC to the host processor. Software access error refers to the error, caused by a un-discovered software bug, which makes software to perform un-supported access to an ASIC location, like writing to a read-only location.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ATM_VCCLASS-3-EDM ### Response: (Severity: 3), (Category: MGBL), (Description: A failure occurred in the ATM VCCLASS EDM backend. As a result the VCCLASS data will not be delievered to the front end.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_VPLS-3-GCS_MAC_LEAK_DETECTED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Host reached max limit on number of mac requests that can be buffered and further requests will fail.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-CHKPT_DEBUG ### Response: (Severity: 3), (Category: OS), (Description: chkpt_iterate_* failed while iterating through the chkpt list.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ST16550-3-ISR_MSR_ERR ### Response: (Severity: 3), (Category: MGBL), (Description: The ST16550 UART driver received too many interrupts within 1 second), (Recommended Action: Too many interrupts received by serial driver. Console cable may be faulty, replace and try again. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the difference between the advertise passive-only and passive-interface commands in IS-IS? ### Response: The passive-interface command suppresses IS-IS hello packets on the specified interface, effectively preventing the formation of IS-IS adjacencies. The advertise passive-only command allows an IS-IS instance to advertise prefixes without actually running IS-IS on that interface. This is useful for advertising loopback or other prefixes into IS-IS without establishing adjacencies. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UCP_OLM-7-LMP_ROUTER_ID_ZERO ### Response: (Severity: 7), (Category: ROUTING), (Description: All existing optical tunnels will NOT come up until an application LMP router ID value is specified using CLI.), (Recommended Action: If MPLS TE optical tunnels do not come up after this change, please make sure that MPLS TE application is using the same router ID as specified in the global router ID.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What happens during the build configuration stage in IOS XR? ### Response: During the build configuration stage in IOS XR, configuration changes are validated and stored in a temporary area without impacting the running system. This allows configuration changes to be made incrementally and verified before being applied. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRIC_DRVR-3-BM_DEAD_NODE_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: All the receive links for a particular stage have gone down triggering the ASIC to go into BM Dead Node. Software will auto recover. Dead node is expected to be seen during plane shut as well as SM OIR where it will result in all receive links of a particular stage to go down.), (Recommended Action: If the error is seen at steady state, software will auto recover. Verify that the fabric is stable. If fabric appears unstable, collected fabric show tech.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTHELPER-6-PKG_DOWNLOAD ### Response: (Severity: 6), (Category: INSTALL), (Description: Status information while starting package download.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NETIO-3-DELETE_FINT ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Interface Manager has requested NetIO to delete the Forwarder Interface. This should not occur - the system assumes the Forwarder Interface is never deleted.), (Recommended Action: When this condition is hit, NetIO will assert and restart in an attempt to recover. If this message continues to be seen Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-5-PER_PREFIX ### Response: (Severity: 5), (Category: ROUTING), (Description: Error while enabling/disabling per route accounting for a route), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-SATELLITE_LMEP_UNPROG_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The local MEP for a Satellite Fabric Link could not be removed. The MEP, Service, Domain will still show in CFM manageability commands despite the Satellite Fabric Link's removal.), (Recommended Action: The extra MEP in CFM manageability commands can be ignored. If this is not possible the delete should be retried by bringing the Satellite Fabric Link up and then removing it again. If this persists, then try restarting the CFM Daemon using the 'process restart' command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VTY-3-TTY_MANAGEMENT ### Response: (Severity: 3), (Category: MGBL), (Description: An unexpected error occurred when the VTY Device DLL interacted with the TTY Management library), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. *RECUR* *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDSFS-7-EDM_INTERNAL ### Response: (Severity: 7), (Category: OS), (Description: RDSFS encountered an internal error within it's EDM, which is a non vital component for normal operation.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DNX_MPLS_EA-3-ERRSTR ### Response: (Severity: 3), (Category: PLATFORM), (Description: DNX MPLS-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFP_LPTS_EA-3-INIT ### Response: (Severity: 3), (Category: L2), (Description: Initialization process such as getting an evm failed. sysmgr will retry to start the cpp_lpts_ea. In case its persistent, contact TAC. *RECUR* *REDUCE*), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support lpts location <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support lpts location <> output, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log. Issue the show lpts trace platform location <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show lpts trace platform location <> output, call your Cisco technical support representative and provide the representative with the gathered information. *SH_CMD show controllers pse qfp infrastructure tcam resource-manager usage location <> *) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-INSTALL_OPERATION_WARNING ### Response: (Severity: 4), (Category: INSTALL), (Description: The behavior of the install operation may not have been entirely what the user expected.), (Recommended Action: Details of the possibly unexpected behavior are provided in 'show install log detail'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETNA-1-ALARM_LOS_PORTP3 ### Response: (Severity: 1), (Category: PLATFORM), (Description: 'Tx CAUI LOS'), (Recommended Action: Check/replace cable. Check/replace optics module.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-6-TRANSCEIVER_INSERTED ### Response: (Severity: 6), (Category: PLATFORM), (Description: This informational message indicates that the optic interface module was inserted on the given interface.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the Bulk Content Downloader (BCDL) service? ### Response: BCDL is a service used to efficiently download large data sets, such as forwarding tables, from routing processes to line cards and fabric cards. It leverages GSP to provide reliable multicast transport. BCDL handles downloading data to multiple consumers, tracks download state, and performs incremental updates. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TOPAZ_PFI-3-INFRA_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This error is an internal infra error and when critical is handled accordingly in the code. The context of the error is provided in the actual code where this error is used. Some of the error conditions that are encountered under this is bind failure, attr query failure, set/get failures, etc. If this error is seen persistently initiate the recommended action.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BM-4-ERR_GLOBAL_OP_RETRY_THRESHOLD ### Response: (Severity: 4), (Category: L2), (Description: After attempting to resend or query information a number of times, the retry threshold has been hit and no more attempts will be made for any global operations. The effect of the message will therefore be lost. The impact will depend on the message which was lost, but the error will give an indication as to the failure. Further information may also be found in show bundle.), (Recommended Action: Restart the Bundle Manager process that reported the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OSPFv3-3-LWM ### Response: (Severity: 3), (Category: ROUTING), (Description: A call to an external light-weight messaging function failed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Please include the output of the following commands: - show logging - show ospfv3 - show ospfv3 trace all) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BGP-4-BMP_MSG_DROPPED ### Response: (Severity: 4), (Category: ROUTING), (Description: The message queue used to enqueue the BMP messages, to be sent down the TCP socket has reached its full configured limit(in number of bytes). The limit will take the default value of 100000 bytes unless configured. Extra BMP messages will be dropped until some space becomes available enough to hold new messages.), (Recommended Action: If BGP has free space and if the configured limit is less than 100000 bytes, then this can be increased to accommodate more messages in queue. This can lead to more memory consumption and reduce memory for regular BGP operations. Dropping of messages can continue if more and more update messages keep coming from the neighbors. Reducing the update churn from the peers can alleviate this problem.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SSE_MPLS_EA-3-ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: SSE MPLS-EA, error), (Recommended Action: *SUPPORT*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LIB_VMAN-3-INCONSISTENT_MEM_CONFIG ### Response: (Severity: 3), (Category: OS), (Description: The virtual service machine definition file is inconsistent in the specification of required memory via the and nodes.), (Recommended Action: Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause. Perform action and if it is still unclear why the memory configuration appears to be inconsistent, file a defect.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CCTL-3-ENVMON_INIT_FAIL ### Response: (Severity: 3), (Category: PLATFORM), (Description: The Envmon process exited due to the reason mentioned in the message.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location <>' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QSM-3-CHECKPOINT_FORMAT ### Response: (Severity: 3), (Category: OS), (Description: A QSM checkpoint record could not be placed in the checkpoint file due to insufficient buffer space.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-FAILED_REPAIR_INDEX_FILE ### Response: (Severity: 7), (Category: INSTALL), (Description: 'An unexpected error occured in cleaning the package index file.'), (Recommended Action: Format device and re-install packages.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: L2FIB-3-STATS_CERR ### Response: (Severity: 3), (Category: L2), (Description: This error occurs when client or DLL initialization fails.), (Recommended Action: Try restarting the process using the command- process restart l2fib_mgr Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOFPGA-7-SB_MBOOT_FAILURE ### Response: (Severity: 7), (Category: DRIVER), (Description: Additional debug infor Secure Boot validation failure.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PMIPV6-3-BA_RESOURCE_FAIL_2 ### Response: (Severity: 3), (Category: IP), (Description: Unable to initialize internal data structure due to the process running low on resources.), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the issue still persists then do the following. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR-3-SHMWIN_MEMORY_CORRUPTION ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: Shmwin has detected a corruption in shared memory of IM DB. There is a likelihood of repeat ifmgr crashes on this node unless the condition is corrected.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PROCFIND-7-SYSDB_EDM_INIT ### Response: (Severity: 7), (Category: OS), (Description: Procfind was unable to initialize its SysDB EDM functions handle, and therefore failed to initialize.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPP-3-CERRNO_REGISTRATION ### Response: (Severity: 3), (Category: SECURITY), (Description: A unexpected failure has been detected while registering the Cerrno DLL.), (Recommended Action: Restarting the concerned process might solve the issue. If the message recurs, issue the following command 'show mgmt-plane trace client both' to gather data and provide the gathered information and the exact error message as it appears to the Cisco technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: I2C-2-PLIM_BYPASSED ### Response: (Severity: 2), (Category: PLATFORM), (Description: PLIM bypass jumper is installed on the MSC. PLIM power up will be bypassed, only MSC will be powered up.), (Recommended Action: Please collect required_info and remove the jumper. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-4-INTF_MTU_TOO_SMALL ### Response: (Severity: 4), (Category: ROUTING), (Description: The MTU for CLNS on the specified interface is too small to allow IS-IS to send packets over that interface. This may be due to a configuration error or an internal error.), (Recommended Action: Check any MTU configuration for the interface to ensure that this is not a configuration error. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-RETIMER_ACCESS_FAIL ### Response: (Severity: 3), (Category: FABRIC), (Description: The device mdio access failed, trying recovery by doing PON reset), (Recommended Action: Collect all the event logs and the output of the following commands executed from the CLI of the active RP if the asic is continuously reset and recovery does not take place after device reset: 1. 'show processes sfe_driver location ' 2. Collect all traces: 'show controller sfe trace all location ' 3. dmesg and /var/log/messages from host and sysadmin VM If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: POS-3-MTU_IMPOSE_FAILED ### Response: (Severity: 3), (Category: L2), (Description: The specified MTU could not be applied on this interface.), (Recommended Action: Try to use an appropriate MTU; supplied MTU value could be either too small or too large) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMFPGA-3-OPTICS_RX_LOS ### Response: (Severity: 3), (Category: PLATFORM), (Description: Optics has detected/cleared LOS on this port), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FDI-3-EES_ANNOUNCEMENT_ERR ### Response: (Severity: 3), (Category: FABRIC), (Description: This process encountered an internal software error. [chars] provide detailed information about this error Process will restart to recover from this error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DPA_PFILTER_EA-3-ERR_L2ACL_MOD ### Response: (Severity: 3), (Category: ACL), (Description: Modification to an attached L2ACL is not supported, only remark can be added/deleted/modified.), (Recommended Action: De-attach the ACL from all interfaces, modify the ACL and re-attach the ACL to all interfaces.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PSB-3-XIPC_THROTTLED_SESSION ### Response: (Severity: 3), (Category: IP), (Description: IP PSB Lib encountered the session, which is casuing the XIPC Queue full.), (Recommended Action: If the message is observed on the console, for this particular session dynamic rate limit policier is applied and may be casue session flap as well.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the Replicated Data Service File System (RDSFS) in IOS XR? ### Response: The Replicated Data Service File System (RDSFS) in IOS XR is used to replicate configuration files and other critical files across RPs for high availability purposes. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_14_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_OUT_OF_BAND_ERROR_14 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SHELFMGR-3-INV_NODEID_IN_CHKPT_MEMORY ### Response: (Severity: 3), (Category: PLATFORM), (Description: API Call to nodeid_extract_fields() failed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INSTMGR-4-FAILED_OUTPUT_WARNING ### Response: (Severity: 4), (Category: INSTALL), (Description: A warning occurred but failed to be output to the user.), (Recommended Action: Repeat the operation. Consult the release-notes if applicable.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: INGRESSQ_DLL-3-ERR_BIST ### Response: (Severity: 3), (Category: FABRIC), (Description: BIST failed for the mentioned block. The driver should trigger a device reset to fix this error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: 12IN1-4-LOOPSTATUS ### Response: (Severity: 4), (Category: L2), (Description: A configurable controller loopback status.), (Recommended Action: No action reqiured. Msg displays loop status) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: TTY-3-MGMT_NO_ATTR ### Response: (Severity: 3), (Category: MGBL), (Description: No attrbiute name was provide to the TTY Management terminal command process.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RVM_MGR-3-TIMER_ERROR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: timer fired), (Recommended Action: none.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: nrs-3-INTERNAL ### Response: (Severity: 3), (Category: OS), (Description: The server has either failed a function that expected to succeed, or has got into an inconsistent state.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QOS-3-ERR_EVM_CREATE ### Response: (Severity: 3), (Category: QOS), (Description: Failed to setup event manager.), (Recommended Action: No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SFE_DRVR-3-ERR_DB_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: SFE driver failed to initialize DB.), (Recommended Action: The driver will restart and try to recover. Make sure the driver restarts and recovers. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_10_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_DISP_ERROR_LANE_INDICATE_10 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CE_TFTP-3-TFTPSERVER_BAG_ENCODE_FAIL ### Response: (Severity: 3), (Category: IP), (Description: As mentioned in the message, the bag encode has failed for the CE-TFTP server.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR ### Response: (Severity: 1), (Category: PLATFORM), (Description: An ASIC error has occured and been handled.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IOSXRV_LIC_MGR-2-INIT_FAILED ### Response: (Severity: 2), (Category: OS), (Description: The IOS XRv license manager was unable to start. This will result in a reload of the router.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPA_INTF_SHELFMGR-3-BIOS_ERROR ### Response: (Severity: 3), (Category: PLATFORM), (Description: BIOS running on the indicated card is reporting an error condition.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: XTC-3-ARG_CHECK_FAILURE ### Response: (Severity: 3), (Category: OS), (Description: An invalid argument was passed to the specified function.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IFMGR_ENCAP-3-SYSDB_SET_ERR ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: The code failed to set a sysdb item while applying encapsulation config. This may be caused due to invalid arguments for which there is no current handling for the same, therefore the system may now be out of sync.), (Recommended Action: Repeat failed configuration command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ISIS-3-ERR_VRFN_FNS_INIT ### Response: (Severity: 3), (Category: ROUTING), (Description: The IS-IS process failed to initialize the handler functions for verification of changes to its configuration data.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. The IS-IS process must be restarted before it can function correctly.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-1-CPU_PKT_CRC_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: IBS from CPP packet CRC error.), (Recommended Action: None.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: Are SMUs platform and release specific in IOS XR? ### Response: Yes, SMUs are platform and release specific in IOS XR. A CRS-1 SMU cannot be applied to a different platform, and vice versa. Furthermore, a release 3.3.4 SMU cannot be applied to release 3.4.2, and vice versa. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CLNS-3-STATSD_REGISTER ### Response: (Severity: 3), (Category: ROUTING), (Description: An operation failed during the Stats Server Interface registration.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the MPLS TE tunnel mode feature? ### Response: The MPLS TE tunnel mode feature allows an MPLS TE tunnel to operate in either global or interface mode. In global mode, the tunnel is associated with the global routing table. In interface mode, the tunnel is associated with a particular interface and is only used to forward traffic arriving on that interface. Interface mode allows better control over tunnel utilization. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CDM_MEMMGR_UTIL-7-REGISTRATION ### Response: (Severity: 7), (Category: HA), (Description: An error was encountered during table registration. The message should indicate the error condition. This is most likely due to a coding error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ACCTD-7-ERR_TTYMGMT_FD ### Response: (Severity: 7), (Category: SECURITY), (Description: Error encountered while using TTY management library.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_L2FIB_LOCSW-6-PFI_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the PFI-IFH module in the platform L2FIB LOCSW component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABRICQ-3-ERR_INIT ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabricq manager encountered an error and is not able recover from the error. A reason text will be supplied call support with this text.), (Recommended Action: The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the fabricq_mgr driver is up and running by executing the following command at the CLI of the active RP: 'admin show process fabricq_mgr location ' If it is still non-operational, enable the following debugs of the fabricq_mgr driver process: error Errors in the driver fatal Fatal errors which cause driver to exit info All informational events init Initialization events and restart the driver by executing the following command at the CLI of the active RP: 'admin process restart fabricq_mgr location ' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FABARBITER-2-XIF_GTFF0_MEM_MBE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Fabric arbiter detected XIF GTFF0 memory multi-bit error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: UCP_OLM-7-LMP_ROUTER_ID_CHANGE ### Response: (Severity: 7), (Category: ROUTING), (Description: All existing optical tunnels will go down and will be re-established using the new router ID value.), (Recommended Action: If optical tunnels do not come up after this change, please make sure that the application is using configured to use the proper LMP router-ID) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD_inv-6-RESET_CARD_FOR_PAIRING ### Response: (Severity: 6), (Category: HA), (Description: The DRP pairing configuration was changed. The card entering or leaving the pair needs to be reset in order to accomodate the new configuration.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CROSSBAR-1-HI_IN_MEM_UCORR_ECC_ERROR_LNK0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected unicast input memory uncorrectable ECC error on link 0), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards are in IOS-XR RUN state, then please reload the card using command: 'hw-module loc <> reload'. Please make sure all the cards in the chassis are properly seated and their ejector handle screws completely tightened. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSTATSC-3-ERR_GSP_GROUP_CREATE ### Response: (Severity: 3), (Category: FABRIC), (Description: Fabric statistics client library encountered an error while creating group for GSP group communication.), (Recommended Action: Restart Fabric statistics client manually if the error is persistent.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLATFORM_SPP_LIB-6-LACP_ON_NON_BUNDLE ### Response: (Severity: 6), (Category: PKT_INFRA), (Description: A physical interface which is not configured as a bundle is receiving a LACP \ packet), (Recommended Action: show im database brief ifh verify the peer why it is sending lacp on the interface from the above interface name These LACP messages are punted and dropped To mitigate, fix the endpoint move to a bundle configuration or apply an l2 ether filter to drop LACP/slow protocol.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_NVSAT_EA-6-CERR_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the cerrno module in the platform NVSAT_EA component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB-3-ERROR_LOG ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLATFORM FIB, Tomahawk specific init error), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show cef platform trace all all loc <>), 'show install active', 'show logging console', 'show platform' and 'show version'. Also notice if the error message is transient or persistent. Report to your technical support representative.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MLAN-6-OPERATION_INFO ### Response: (Severity: 6), (Category: PLATFORM), (Description: The particular operation mentioned in the message gave an informative message. This is not a failure.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CHKPT_HEAP-7-SEGMENT_RENAMED ### Response: (Severity: 7), (Category: HA), (Description: A corrupted checkpoint segment has been renamed for later analysis.), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IMUX-1-RX_BRST_LEN_ERR ### Response: (Severity: 1), (Category: PLATFORM), (Description: Ingress MUX encountered Rx burst short or burst length error.), (Recommended Action: This fault would result in traffic loss. Ensure the ingress MUX FPGA version is latest. Reload the card if the fault is persistent. Contact support if reload of card does not clear the fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: DISCOVERY-7-CPU_DETAILS ### Response: (Severity: 7), (Category: PLATFORM), (Description: Details about the error seen in CPU module.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NPUXBAR_BRIDGE-3-RSPI_PROT_CTR_ERR ### Response: (Severity: 3), (Category: PLATFORM), (Description: RxSPI protocol unexpected control word error.), (Recommended Action: Minor error, no action required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RAW-3-INIT_ERR ### Response: (Severity: 3), (Category: IP), (Description: An software error occurred while starting up of RAW process. If this occurred during process startup, then the process may be restarted.), (Recommended Action: The process will attempt to recover from this situation by restarting. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise if the message's error code indicates that the failure was due to lack of memory, then take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If the problem was not caused by memory allocation and it hasn't been corrected by subsequence restarts then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: tunnel_ea-3-EVM_CREATE_FAILED ### Response: (Severity: 3), (Category: PKT_INFRA), (Description: This is an internal error in tunnel ea. The failure is while tunnel_ea is creating an event manager. The actual cause of the failure could be due to memfail/invalidargs etc.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.') <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLMGR-6-DEVICE_ENABLED ### Response: (Severity: 6), (Category: OS), (Description: A device is enabled for logging onboard by user configuration.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VPDN-4-CALL_IPC_DISCONNECT ### Response: (Severity: 4), (Category: SUBSCRIBER), (Description: The VPDN CALL IPC failed to disconnect as a result of configuration or an internal error. In some cases, this warning message may be harmless.), (Recommended Action: If VPDN problems persist, you may need to restart vpdn_mgr or this client process.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: OBFLINFRA_INT-3-RECORD_VERSION_MISMATCH ### Response: (Severity: 3), (Category: OS), (Description: A feature record has different version format with current software.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PKG-7-MISSING_PIE_ATTRIBUTE ### Response: (Severity: 7), (Category: INSTALL), (Description: PIE file appears to be damaged.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LC_PIDB-2-INIT_FAILURE ### Response: (Severity: 2), (Category: PLATFORM), (Description: Above run time error occurred while initializing the pidb on the linecard.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers sip-pm trace pidb location <> command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers sip-pm trace pidb location <> output, call your Cisco technical support representative and provide the representative with the gathered information. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-1-MAC_0_TX_FIFO_OFLOW_0 ### Response: (Severity: 1), (Category: PLATFORM), (Description: MAC on NPU-0 had transmit fifo overflow on bridge instance-0.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD_HFR-3-EDM_ACT_SETUP ### Response: (Severity: 3), (Category: ROUTING), (Description: MFWD-HFR library encountered error while initializing the EDM action event handlers), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CPAK-2-LANE_4_HIGH_TX_POWER_ALARM ### Response: (Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Tx power greater than or equal to the high Tx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Tx power threshold values are read from the CPAK.), (Recommended Action: Verify that the device is properly inserted. Replace the CPAK with a working one (if any) to isolate bad optics. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show tech-support ethernet interface location ', 'show hw-module fpd location all' and 'admin show inventory'.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How to configure a loopback interface? ### Response: To configure a loopback interface in Cisco IOS XR, use the 'interface Loopback' command in global configuration mode. RP/0/RP0/CPU0:router(config)#interface Loopback0 RP/0/RP0/CPU0:router(config-if)#ipv4 address 10.1.1.1 255.255.255.255 <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-KA_CFG_ENQUEUE ### Response: (Severity: 3), (Category: FORWARDING), (Description: Failed to send the specified event from tunl_gre_ma's main thread to the keep-alive thread or vice-versa. This may result in errorneous keep-alive behavior for the tunnel specified.), (Recommended Action: Recommeded action is to disable the Keep-alive on tunnel. If keep-alive is a must, restart the process using following command. process restart tunl_gre_ma) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ROULETTE-6-RP_ISOLATION ### Response: (Severity: 6), (Category: PLATFORM), (Description: This is an informational message indicating that target RP has transitioned into RP isolation.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: LRD-4-UNEXPECTED ### Response: (Severity: 4), (Category: HA), (Description: An unexpected condition encountered. This is not necessarily an error, but may help with debugging other problems elsewhere!), (Recommended Action: Collect system log information. No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-IM ### Response: (Severity: 4), (Category: L2), (Description: ELMI encountered an error communicating with Interface Manager. The error message describes what operation has failed and why it failed. The most likely reason for this is a temporary connection problem with the Interface Manager Control Server, but the error could also be caused by low memory resource or programming error.), (Recommended Action: In many cases, ELMI will recover by itself. If it does not then restarting the process may help. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ETH_SRVR_API-3-UNKNOWN_OFFSET_PASSED ### Response: (Severity: 3), (Category: PLATFORM), (Description: Unkown packet offset passed.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COND_DEB_RP-6-ILLIPVAL ### Response: (Severity: 6), (Category: SECURITY), (Description: Illegal IP-address and/or IP-mask were configuring as condition to crypto debug message.), (Recommended Action: Fix the values of IP-address and/or IP-mask in the 'debug condition crypto IPv4...' command.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: COHERENT-3-UPGRADE_CFP2_LASER_ON ### Response: (Severity: 3), (Category: PLATFORM), (Description: Cannot do FPD upgrade of CFP2 when its laser is on.), (Recommended Action: Shut the Optics Controller corresponding to this CFP2 and try upgrade again.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKET-3-ASYNC_SOCKETS_ABORTED ### Response: (Severity: 3), (Category: IP), (Description: The socket library aborted sockets belonging to the application due to system instability.), (Recommended Action: The information in required_info to be collected and engineering team to be notified. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FSDB_SVR-3-CM_INIT_FAILURE ### Response: (Severity: 3), (Category: FABRIC), (Description: FSDB server failed CM initialization with above reson.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: What is the purpose of the 'import route-target' and 'export route-target' commands in IOS XR L3VPN configuration? ### Response: The 'import route-target' and 'export route-target' commands are used to control the import and export of routes between VRFs. The 'import route-target' specifies which routes should be imported into the VRF from other VRFs. The 'export route-target' specifies which routes should be exported from the VRF to other VRFs. Route targets define the VPN membership and allow the creation of extranets. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SKYWARP_LICENSE-2-INFRA_VRF_NEEDED ### Response: (Severity: 2), (Category: LICENSE), (Description: The VRF feature is configured without the necessary iVRF license.), (Recommended Action: The customer should either purchase the license or disable the feature.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: 10GE_PLIM-6-OIM_OIR ### Response: (Severity: 6), (Category: L2), (Description: The Optic Interface Module (OIM) for the specified port has either been inserted or removed.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLUTLU-3-MIPC_ERR_NOTIF ### Response: (Severity: 3), (Category: PLATFORM), (Description: PLU received notification from MIPC due to unrecoverable error or invalid address. PLU downloads the entire table to hardware as a recovery mechanism. This is an informational message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: RDS-3-WRITE_TIMEDOUT ### Response: (Severity: 3), (Category: OS), (Description: RDS library uses ENS/GSP services to read/write data. While using ens API , it returned failure. RDS write has not been able to write successfully and has timed out.This may be due to message size or underlying problems in transport.RDS will retry to write again.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ELMI-4-AIPC ### Response: (Severity: 4), (Category: L2), (Description: ELMI encountered an error using the AIPC infrastructure. The error message describes what operation has failed and why it failed. This is most likely to be due to a low memory condition but may also be an internal programming error.), (Recommended Action: Consider restarting the ELMI process. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPSEC_SVI_NETIO-3-INIT_DEBUG ### Response: (Severity: 3), (Category: SERVICES), (Description: A failure occurred during the initialization of debug for the NetIO caps. If this occured during an upgrade operation then it will cause the NetIO process to reload. Otherwise this will cause the capsulation to be unloaded, and an error returned to the user.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: GROUP_MEMBERSHIP-4-OOR_THRESHOLD_REACHED ### Response: (Severity: 4), (Category: ROUTING), (Description: Maximum number of groups accepted, either per interface or per vrf.), (Recommended Action: No action is required.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: BRIDGE-3-CRC_ERR_0_NPU_1 ### Response: (Severity: 3), (Category: PLATFORM), (Description: CRC error from NPU-0 on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'reload location <>'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: VIC-3-MIB_STATS ### Response: (Severity: 3), (Category: PLATFORM), (Description: MIB stats collection failed due to some internal error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. - sh platform - sh processes vic location <> - show tech-support ethernet interface) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CFM-4-NOTIFY_LOSS_FAILED ### Response: (Severity: 4), (Category: L2), (Description: The CFM packet handling module has detected that a peer MEP has timed out (ie that no CCM has been received for the loss time), but has failed to notify the management module. As a result, the proper handling for this event (eg generating log messages and SNMP traps) will not take place.), (Recommended Action: If the error persists, the problem may be corrected by restarting the cfmd process on the node where the problem is being reported.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IP_TUNNEL-3-IF_DELETE ### Response: (Severity: 3), (Category: FORWARDING), (Description: An error was encountered in deleting the interface for the specified tunnel.), (Recommended Action: Restart tunnel GRE MA process by executing the following command. process restart tunl_gre_ma) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: MPLS_TE-6-LINK_DISC_SRLG_CHG ### Response: (Severity: 6), (Category: ROUTING), (Description: The SRLGs discovered during signaling of the GMPLS-UNI tunnel associated with the specified controller have changed.), (Recommended Action: None. This is a solicited message and is informative only.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CARD_MGR-3-CPU_BOARD_INTR ### Response: (Severity: 3), (Category: DRIVER), (Description: Card manager has detected CPU ERROR. Sources for this error could be one of PCI device present in the system), (Recommended Action: IN case of ERR_CORR no action is required. In case of ERR_NONFATAL and ERR_FATAL node is reloaded. An auto logging is fired which has collected log in /misc/disk1/cpu_interrupt_*.log Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: QFPCPUBridgeFPGA-3-INT_HT0_DROP_INT ### Response: (Severity: 3), (Category: PLATFORM), (Description: HT0 Drop Inband Message Event: HT Inband Interrupt(s) have been filtered and dropped due to a previously sent MSI that has set the H/W mask and has not been cleared by S/W.), (Recommended Action: Save log file and report this error. If the issue persists, reset the line card.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: IPV4_MFWD-3-ERR_EVM_INIT_EVENT ### Response: (Severity: 3), (Category: ROUTING), (Description: Internal error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SONETMIBCORE-3-LTRACE_INIT ### Response: (Severity: 3), (Category: SNMP), (Description: Ltrace initialization failed. It shouldn't hamper the functionality.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: NVGEN-3-ENDCOPTIONNOTPRESENT ### Response: (Severity: 3), (Category: MGBL), (Description: 'end option mark is missing in the command. The calling function the coption id and the command are are displayed in the message'), (Recommended Action: *SH_TECH*) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: CIH-1-ASIC_ERROR_PON_RESET_START ### Response: (Severity: 1), (Category: PLATFORM), (Description: An ASIC error has occured and need power on reset, this mark the beginning of it.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SOCKIO-4-CTX_SHORTAGE ### Response: (Severity: 4), (Category: PKT_INFRA), (Description: Set: A global SPP context shortage was detected in the SockIO plug-in. Reception of packets from ports and other nodes is likely to stop at any point. Clear: A previous SPP context shortage was cleared. Normal packet I/O operations will resume.), (Recommended Action: If the problem does not clear, the node should be reloaded.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: How does IOS XR handle configuration during router startup? ### Response: During router startup, IOS XR loads the committed configuration from the Configuration File System (CFS). If there are no configuration inconsistencies or failures, the router starts with the committed configuration. <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PCMCIA-2-HBA_FAIL ### Response: (Severity: 2), (Category: PLATFORM), (Description: PCMCIA was not able to register iteslf as a handler for PCMCIA related interrupts. This could have happened because of failure in setting the IRQ thread properties or failure in attaching to interrupt.), (Recommended Action: Reinsert the card. If not able to recover after OIR, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: ITAL-7-REG_FAILURE ### Response: (Severity: 7), (Category: OS), (Description: Registration operation with a certain server failed. The message displays the reasons.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. if message floods the console continuously and router is not able to recover from this situation.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: SPA_ETHER-1-LTRACE_INIT_ERR ### Response: (Severity: 1), (Category: L2), (Description: Jacket process spawns the SPA process and waits for the initialization to complete. But initialization fails putting SPA into FAILED state. As a part of the above, we find the mesage Ltrace init failed message.), (Recommended Action: If the issue occurs, Check the SPA state. If it is not OK, then collect the following traces 1) show plim jacket all location 2) show hw-module traces infra detailed location 3) show plim ether trace info/error location 4) console logs) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: FIA-1-SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_3_0 ### Response: (Severity: 1), (Category: FABRIC), (Description: SKT_SMC0_INTR_OOB_ERROR_LANE_INDICATE_3 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location <>'. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.) <|EOT|> " "<|begin▁of▁sentence|> ### Instruction: PLAT_FIB_HAL-3-ERR_INFO_RT ### Response: (Severity: 3), (Category: PLATFORM), (Description: Error information in PLATFORM FIB HAL), (Recommended Action: Please collect the console log, FIB traces (show cef trace loc <>), FIB platform trace (show logging, show version, show platform, show install active, show cef platform trace all all loc <>). (show cef mpls local-label